| 4441 |
CIPET. MYSURU
| 6113734
| IS 7834 : Part 3 (1987) |
injection moulded PVC socket fittings with solvent cement joints for water supplies: Part 3 Specific requirements for 90 degree elbows |
- |
7294 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| cl 2.2.2(Dimensions) |
- |
375 |
|
For Dimensions Thickness & Socket length) |
| Cl. 2.1 (Ref. Cl. 6.3 of IS 7834 (part 1) : 1987(Effect on water - Lead (first extraction) - Appendix C ) |
- |
2250 |
|
For EOW Including all element detection |
| Cl. 2.1 (Ref. Cl. 6.3 of IS 7834 (part 1) : 1987(Effect on water - Lead (third extraction) - Appendix C) |
- |
0 |
|
Included above |
| Cl. 2.1 (Ref. Cl. 6.3 of IS 7834 (part 1) : 1987(Effect on water - Dialkyl tin C4 and higher homologues measured as tin (third extraction) - Appendix C) |
- |
0 |
|
Included above |
| Cl. 2.1 (Ref. Cl. 6.3 of IS 7834 (part 1) : 1987(Effect on water - Other toxic substances (third extraction) - Appendix C) |
- |
4668.75 |
|
EOW water charges included above,
RS.1593 is for addition of (Stress relief test Rs. 525, OpacityRs. 431.25, Short-term hydraulic test Rs. 637.50) Rs. 637.50 for socket fitting . And
Rs. 3075 for raw material ( VCM Content Rs.2250 & K Value Rs. 825) |
| 2.2.2 table 1(Laying length) |
- |
0 |
|
- |
| 6.1.1(VCM Content Test) |
- |
2250 |
|
- |
|
31 Dec, 2026 |
- - |
| 4442 |
CIPET. MYSURU
| 6113734
| IS 7834 : Part 5 (1987) |
Injection Moulded PVC Socket Fittings With Solvent Cement Joints for Water Supplies - Part 5 : Specific Requirements for 45 degree Tees |
- |
7294 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 2.2.2, Table 1(Size) |
- |
375 |
|
All DImensions |
| 2.2.2, Table 1(45 ĚŠ Tees Laying
Length, Z) |
- |
0 |
|
Included in above dimension charges |
| 2.2.3( inside diameter of the socket) |
- |
0 |
|
Included in above dimension charges |
| 2.2.3(Socket length) |
- |
0 |
|
Included in above dimension charges |
| 2.1(General) |
- |
6918 |
|
RS.3843 is for addition of (Stress relief test Rs. 525, OpacityRs. 431.25, EOW. Rs.2250, &Short-term hydraulic test Rs. 637.50) Rs. 637.50 for socket fitting . And
Rs. 3075 for raw material ( VCM Content Rs.2250 & K Value Rs. 825) |
| 6.1.1(VCM Content Test) |
- |
0 |
|
- |
|
31 Dec, 2026 |
- - |
| 4443 |
CIPET. MYSURU
| 6113734
| IS 7834 : Part 7 (1987) |
injection moulded PVC socket fittings with solvent cement joints for water supplies: Part 7 Specific requirements for unions |
- |
7294 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 2.2.2, Table 1(Size) |
- |
375 |
|
For All Dimensions |
| 2.2.2, Table 1(Union Laying
Length) |
- |
0 |
|
Included in above dimension charges |
| 2.2.3( inside diameter of the socket) |
- |
0 |
|
Included in above dimension charges |
| 2.2.3(Socket length) |
- |
0 |
|
Included in above dimension charges |
| 2.1(General) |
- |
0 |
|
Added in below charges |
| 2.1(General) |
- |
6918.75 |
|
RS.3843 is for addition of (Stress relief test Rs. 525, OpacityRs. 431.25, EOW. Rs.2250, &Short-term hydraulic test Rs. 637.50) Rs. 637.50 for socket fitting . And
Rs. 3075 for raw material ( VCM Content Rs.2250 & K Value Rs. 825) |
| 6.1.1(VCM Content Test) |
- |
0 |
|
- |
|
31 Dec, 2026 |
- - |
| 4444 |
CIPET. MYSURU
| 6113734
| IS 12701 (1996) |
Rotational moulded polyethylene water storage tanks - specification (First Revision) |
Upto 20000 litres |
17144 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4.2.3(Carbon Black Content ) |
- |
693.75 |
|
CBC |
| 4.2.3(Carbon Dispersion Test) |
- |
525 |
|
CBD |
| 5(Types and Features ) |
- |
1200 |
|
CL. 4.1.1 density & MFI |
| 5.1 Table 1(Dimensioas of Cylinderical Vertical Tank) |
- |
2512.50 |
|
5.1,5.2,5.3&5.4 & 6.1 |
| 7.1.1(Resistance to Deformation) |
- |
525 |
|
Resistance to Deformation |
| 7.2(Resistance to Impact) |
- |
825 |
|
Resistance to Impact |
| 7.3(Test for Top Load Resistance) |
- |
675 |
|
Test for Top Load Resistance |
| 7.4(Tensile Strength) |
- |
1325 |
|
Tensile Strength |
| 7.5(Flexural Modulus) |
- |
1325 |
|
Flexural Modulus |
| 7.6(overall Migration) |
- |
7537.50 |
|
Cl. 7.6, 9.1, 8.2 & Raw material |
| 5.4(Wall Thickness) |
- |
0 |
|
- |
| 6.1(Finish) |
- |
0 |
|
- |
| 9.2.1(Man-Hole and Hand-Hole Lids) |
- |
0 |
|
- |
| 4.2.2(MFR) |
- |
0 |
|
- |
|
31 Dec, 2026 |
- - |
| 4445 |
CIPET. MYSURU
| 6113734
| IS 7834 : Part 8 (1987) |
injection moulded PVC socket fittings with solvent cement joints for water supplies: Part 8 Specific requirements for caps |
- |
7294 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 2.2.2(diameter of the socket of cap) |
- |
375 |
|
For All Dimensions |
| 2.1(General) |
- |
6918.75 |
|
RS.3843 is for addition of (Stress relief test Rs. 525, OpacityRs. 431.25, EOW. Rs.2250, &Short-term hydraulic test Rs. 637.50) Rs. 637.50 for socket fitting . And
Rs. 3075 for raw material ( VCM Content Rs.2250 & K Value Rs. 825) |
| 6.1.1(VCM Content Test) |
- |
0 |
|
- |
|
31 Dec, 2026 |
- - |
| 4446 |
Institute for Auto Parts and Hand Tools Technology, Ludhiana
| 9126034
| IS 6149 (1984) |
Specification for single - Ended open - Jaw adjustable wrenches (First Revision) |
All Grade, Type, Size and Designation |
6840 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4 Table-1(Dimensions- Nominal Size) |
- |
1200 |
|
- |
| 4 Table-1(Dimensions- a) |
- |
0 |
|
-- |
| 4 Table-1(Dimensions- b) |
- |
0 |
|
-- |
| 4 Table-1(Dimensions- t) |
- |
0 |
|
-- |
| 4 Table-1(Dimensions- d) |
- |
0 |
|
-- |
| 4 Table-1(Dimensions- Opening of adjustable jaws) |
- |
0 |
|
-- |
| 6(Hardness- Frame, handle and Jaw) |
- |
3560 |
|
Hardness= 400
Coating Thickness- 460
Adhesion Test- 200
Corrosion Resistance- 2000
Workmanship=500 |
| 8(Longitudinal Play of Adjustable Jaw) |
- |
300 |
|
--- |
| 8(Transverse Play of Adjustable Jaw) |
- |
300 |
|
--- |
| 8(Torque) |
- |
500 |
|
--- |
| 5(Chemical Composition) |
- |
980 |
|
- |
|
17 Feb, 2028 |
- - |
| 4447 |
CIPET. MYSURU
| 6113734
| IS 12786 (1989) |
Irrigation equipment - Polyethylene pipes for irrigation laterals - Specification |
Diameter - 32 mm |
13325 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4.1.a (Potyethylene - higher olefins constituent ) |
- |
1500 |
|
Potyethylene - higher olefins constituent |
| 7.3(Tensile Test) |
- |
975 |
|
For tensile & Elongation |
| 7.3(Elongation at Break) |
- |
0.00 |
|
included in tensile |
| 7.4(SusceptibiIity to Environmental Stress
Cracking) |
- |
900.00 |
|
E s c r |
| 5 and Table 1(DIMENSIONS OF PIPES - outside diameters) |
- |
0 |
|
For all dim |
| 7.2(Reversion Test) |
- |
825.00 |
|
reversion
Rs. 525 test & RS. 300 Specimen prep |
| 5 and Table 1(DIMENSIONS OF PIPES - wall thickness shall) |
- |
375 |
|
Dimension charges |
| 4.1.c.ii (Toluene extract - Annex A) |
- |
900 |
|
Toluene extract - |
| 4.1.c.iii (Volatile matter - Annex B ) |
- |
900 |
|
Volatile matter |
| 4.1.c & 4.2.a (Carbon Black content - IS 2530 : 1963) |
- |
694 |
|
CBC |
| 4.2.b (The dispersion of Carbon Black content shall be satisfactory - IS 2530 : 1963) |
- |
525.03 |
|
The dispersion of Carbon Black content shall be satisfactory - IS 2530 : 1963 |
| 7.1
Table-2
(b)Acceptance Test for 01 hour at 20°C & 6.9MPa induced stress) |
- |
638 |
|
b) Acceptance Test for 01 hour at 20°C & 6.9MPa induced stress |
| Cl. 7.1 Table -2(Quality Test for 100 hrs @ 70 c & 2.2 Mpa) |
- |
2250.01 |
|
Quality Test for 100 hrs @ 70 c & 2.2 Mpa |
| 6(VISUAL APPEARANCE) |
- |
225 |
|
VISUAL APPEARANCE |
| 4.1.c.i (Density) |
- |
1200 |
|
Density |
| 4.1d(MATERIAL) |
- |
1500 |
|
MATERIAL |
|
31 Dec, 2026 |
- - |
| 4448 |
CIPET. MYSURU
| 6113734
| IS 14333 (2022) |
Polyethylene Pipes for Sewerage and Industrial Chemicals and Effluent � Specification (First Revision) |
Diameter upto 400mm |
39545 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 7.4,T3 of IS 4984(Outside Diameter-IS 4984-2016) |
- |
375 |
|
Dimension all |
| 5.2.1,T2("Base Density
(At 27°C Temp.)-IS 7328:2020 ") |
- |
1200 |
|
Density |
| 6.2(Colour- IS 14333-2022) |
- |
225 |
|
Colour |
| 8.1.1, T4(Internal Pressure creep Rupture test, Temperature - 27 oC , Test Period - 100 hrs.-IS 4984-2016 (Annexure-E)) |
- |
2250 |
|
100 hrs Pressure test |
| 8.1.1, T4(Internal Pressure creep Rupture test, Temperature - 80 oC , Test Period - 48 hrs.-IS 4984-2016 (Annexure-E)) |
- |
1200 |
|
48 hrs pressure test |
| 8.2("Longitudinal Reversion Test - IS 4984-2016
(Annexure-F)") |
- |
825 |
|
Reversion |
| 8.6(Density-IS 7328:2020) |
- |
1200.01 |
|
Density |
| 8.4(Melt Flow rate(Temperature - 190oC,Mass 5kg)-IS 2530-1963) |
- |
900 |
|
MFI |
| 8.3(Carbon black content- IS 2530-1963) |
- |
694 |
|
CBC |
| 8.3(Carbon black content Dispersion- IS 2530-1963) |
- |
525 |
|
CBD |
| 7.4,T4 of IS 4984(wall Thickness-IS 4984-2016) |
- |
0 |
|
Dimension |
| 7.4,T3 of IS 4984(Ovality-IS 4984-2016) |
- |
0 |
|
Dimension |
| 5.2.1,T2(Melt Flow Rate (At 190°C /5kg)-IS 2530:1963) |
- |
900 |
|
MFI |
| 5.2.1,T2(Thermal Stability(Oxidation Induction Time)-IS 4984:2016(Annexure-B)) |
- |
1650 |
|
OIT |
| 5.2.1,T2("Volatile Matter- IS 4984:2016
(Annexure-C)") |
- |
900 |
|
Volatile |
| 5.2.1.1, T2(Compound Density-IS 7328:2020) |
- |
525 |
|
Density |
| 5.2.1.1, T2("Compound carbon black -IS 2530:1963
content") |
- |
694.01 |
|
CBC |
| 5.2.1.1, T2(Compound Toluene extract - Any Method) |
- |
900 |
|
Toluene |
| 5.2.1.1, T2(Compound maximum volatile matter -IS 4984:2016 (Annexure-C)) |
- |
900 |
|
Volatile matter |
| 5.2.1.1, T2(Compound ash content - Any Method) |
- |
900 |
|
Ash |
| 5.2.1.1, T2("Compound carbon black -IS 2530:1963
dispersion") |
- |
694 |
|
CBC |
| 5.3(Density of Higher olefin - IS 7328:2020) |
- |
525 |
|
Density |
| 5.3(Loading of Carbon Black - IS 2530:1963) |
- |
694 |
|
Carbon Black |
| 5.3(Ash content- Any Method) |
- |
900 |
|
Ash Content |
| 5.3(Toluene extract - Any Method) |
- |
825 |
|
Toluene |
| 5.3("Maximum volatile matter -IS 4984:2016
(Annexure-C)") |
- |
825 |
|
volatile matter |
| 6(Pipe Description - IS 14333-2022) |
- |
225 |
|
Visual |
| 8.1.1, T4(Internal Pressure creep Rupture test, Temperature - 80 oC , Test Period - 165 hrs.-IS 4984-2016 (Annexure-E)) |
- |
2249.97 |
|
165 hrs.-Internal Pressure creep Rupture test, |
| 8.1.1, T4(Internal Pressure creep Rupture test, Temperature - 80 oC , Test Period - 1000 hrs.-IS 4984-2016 (Annexure-E)) |
- |
8250 |
|
1000 hrs.-Internal Pressure creep Rupture test, |
| 8.1.2, T4(Internal Pressure creep Rupture test, Temperature - 80 oC , Test Period - 48 hrs.-IS 4984-2016 (Annexure-E)) |
- |
1200 |
|
48 hrs.-Internal Pressure creep Rupture test, |
| 8.5(Oxidation Induction Time -IS 4984:2016(Annexure-B)) |
- |
1650.01 |
|
OIT |
| 8.7("Tensile Strength for Butt Fusion - IS 4984-2016
(Annexure-G)") |
- |
975 |
|
Butt Fusion tensile |
| 8.8,T5("Tensile - IS 4984-2016
(Annexure-H)") |
- |
975 |
|
Tensile |
| 8.8,T5("Elongation -IS 4984-2016
(Annexure-H)") |
- |
0 |
|
Included in tensile |
| 8.9(Slow Crack Growth Rate{Internal Pressure creep Rupture test, Temperature - 80±1 oC , Test Pressure – 0.80MPa, Test Period - 500 hrs.-IS 4984-2016 (Annexure-E &J)) |
- |
1200 |
|
Slow Crack Growth Rate |
|
31 Dec, 2026 |
- - |
| 4449 |
CIPET. MYSURU
| 6113734
| IS 2508 (2016) |
Polyethylene films and sheets - Specification (Third Revision) |
Films |
24106.25 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 5.1.1(Appearance) |
- |
225 |
|
Test charges after 25% BIS Discount from our actual Approved charges |
| 5.1.2(Film Form) |
- |
0 |
|
Test charges included In Appearance |
| 5.1.3(Odour) |
- |
0 |
|
Test charges included In Appearance |
| 5.1.4(Density, Cl.5 of IS 13360(Part-3/Section-1)) |
- |
375 |
|
Test charges after 25% BIS Discount from our actual Approved charges |
| 5.1.5(Melt Flow Index. Cl 6, 7 of IS 13360(Part-4/Section-1)) |
- |
825 |
|
Test charges after 25% BIS Discount from our actual Approved charges |
| 5.1.6a(Carbon Black Content, Annex-A) |
- |
693.75 |
|
Test charges after 25% BIS Discount from our actual Approved charges |
| 5.1.6b(Ash Content, Annex-A) |
- |
600 |
|
Test charges after 25% BIS Discount from our actual Approved charges |
| 5.1.6c(Carbon Black Dispersion, Cl.16 of IS 2530) |
- |
525 |
|
Test charges after 25% BIS Discount from our actual Approved charges |
| 5.2.2(Tolerance on Thickness, Annex-A) |
- |
187.50 |
|
Test charges after 25% BIS Discount from our actual Approved charges |
| 6.1, Table 1(Tensile strength at break. A) Machine Direction. IS 13360 (Part 5/Sec 1)) |
- |
1075 |
|
Test charges after 25% BIS Discount from our actual Approved charges |
| 6.1, Table 1(Tensile strength at break. B) Transverse Direction. IS 13360 (Part 5/Sec 3)) |
- |
1075 |
|
Test charges after 25% BIS Discount from our actual Approved charges |
| 6.1, Table 1(Ageing test at (70-1)c for 7 days , cl 4 IS 7016 ) |
- |
525 |
|
Test charges after 25% BIS Discount from our actual Approved charges |
| 6.1, Table 1(Elongation at break ,A) Machine direction .IS 13360(Part-5/sec-1) ) |
- |
0 |
|
Test charges included In Tensile properties |
| 6.1, Table 1(Elongation at break ,B) Cross-machine direction..IS 13360(Part-5/sec-3) ) |
- |
0 |
|
Test charges included In Tensile properties |
| 6.1, Table 1(Dartimpact strength Method B of IS 13360 (Part-5/sec-6) ) |
- |
637.50 |
|
Test charges after 25% BIS Discount from our actual Approved charges |
| 6.1, Table 1(Tear resistence. A) Machine direction Annex B) |
- |
825 |
|
Test charges after 25% BIS Discount from our actual Approved charges |
| 6.1, Table 1(Tear resistence. B) Transverse direction ) |
- |
825 |
|
Test charges after 25% BIS Discount from our actual Approved charges |
| 7.1. Table 2(Tensile strength at break A) Machine direction IS 13360 (Part-5/sec-1) ) |
- |
1075 |
|
Test charges after 25% BIS Discount from our actual Approved charges |
| 7.1. Table 2(Tensile strength at break,B) Crosse machine direction IS 13360 (Part-5/sec-3) ) |
- |
1075 |
|
Test charges after 25% BIS Discount from our actual Approved charges |
| 7.1. Table 2(Ageing test at (70-1)c for 7 days , cl 4 IS 7016 ) |
- |
525 |
|
Test charges after 25% BIS Discount from our actual Approved charges |
| 7.1. Table 2(Elongation at break , A) Machine direction IS 13360 (Part-5/sec-3) IS 13360 (Part-5/sec-1) ) |
- |
0 |
|
Test charges included In Tensile properties |
| 7.1. Table 2(Elongation at break , A) Transverse direction IS 13360 (Part-5/sec-3) ) |
- |
0 |
|
Test charges included In Tensile properties |
| 7.1. Table 2(Dart impact strenght , Method A of IS 3360 (Part-5/sec-6) ) |
- |
637.50 |
|
Test charges after 25% BIS Discount from our actual Approved charges |
| 8.1, Table 3(Tensile properties ,A) Yield strenght . IS 3360 (Part-5/sec-1) and IS 3360 (Part-5/sec-3) Test condition- specimen type 5 and test speed 51 mm/min do) |
- |
1075 |
|
Test charges after 25% BIS Discount from our actual Approved charges |
| 8.1, Table 3(Tensile properties , B) Break strenght . IS 3360 (Part-5/sec-1) and IS 3360 (Part-5/sec-3) Test condition- specimen type 5 and test speed 51 mm/min do) |
- |
1075 |
|
Test charges after 25% BIS Discount from our actual Approved charges |
| 8.1, Table 3(Tensile properties ,C) Yield elongation . IS 3360 (Part-5/sec-1) and IS 3360 (Part-5/sec-3) Test condition- specimen type 5 and test speed 51 mm/min do) |
- |
1075 |
|
Test charges after 25% BIS Discount from our actual Approved charges |
| 8.1, Table 3(Tensile properties ,D) Break elongation . IS 3360 (Part-5/sec-1) and IS 3360 (Part-5/sec-3) Test condition- specimen type 5 and test speed 51 mm/min do) |
- |
1075 |
|
Test charges after 25% BIS Discount from our actual Approved charges |
| 8.1, Table 3(Tear resistance , Annex B) |
- |
825 |
|
Test charges after 25% BIS Discount from our actual Approved charges |
| 8.1, Table 3(Puncture resistance , Annex C) |
- |
1075 |
|
Test charges after 25% BIS Discount from our actual Approved charges |
| 9.1, Table 4(Tensile properties ,A) Yield strenght . IS 3360 (Part-5/sec-1) and IS 3360 (Part-5/sec-3) Test condition- specimen type 5 and test speed 51 mm/min do) |
- |
1075 |
|
Test charges after 25% BIS Discount from our actual Approved charges |
| 9.1, Table 4(Tensile properties , B) Break strenght . IS 3360 (Part-5/sec-1) and IS 3360 (Part-5/sec-3) Test condition- specimen type 5 and test speed 51 mm/min do) |
- |
1075 |
|
Test charges after 25% BIS Discount from our actual Approved charges |
| 9.1, Table 4(Tensile properties ,C) Yield elongation . IS 3360 (Part-5/sec-1) and IS 3360 (Part-5/sec-3) Test condition- specimen type 5 and test speed 51 mm/min do) |
- |
1075 |
|
Test charges after 25% BIS Discount from our actual Approved charges |
| 9.1, Table 4(Tensile properties ,D) Break elongation . IS 3360 (Part-5/sec-1) and IS 3360 (Part-5/sec-3) Test condition- specimen type 5 and test speed 51 mm/min do) |
- |
1075 |
|
Test charges after 25% BIS Discount from our actual Approved charges |
| 9.1, Table 4(Tear resistance , Annex B) |
- |
825 |
|
Test charges after 25% BIS Discount from our actual Approved charges |
| 9.1, Table 4(Puncture resistance , Annex C) |
- |
1075 |
|
Test charges after 25% BIS Discount from our actual Approved charges |
| 5.2.1.2(Nominal width) |
- |
0 |
|
- |
|
31 Dec, 2026 |
- - |
| 4450 |
Planet Electro Labs Private Limited, Wazirpur
| 8185226
| IS/IEC 60947 : Part 5 : Sec 2 (2019) |
LLow-Voltage Switchgear and Controlgear Part 5 Control Circuit Devices and Switching Elements Section 2 Proximity Switches ( First Revision ) |
- |
2200000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 5.1(General) |
- |
2000 |
|
- |
| 5.2(Operating conditions) |
- |
10000 |
|
- |
| 6.2(Marking) |
- |
5000 |
|
- |
| 5.3(Rated and limiting values for the proximity switch and switching element(s)) |
- |
35000 |
|
- |
| 6.4(Environmental information) |
- |
5000 |
|
- |
| 7(Normal service, mounting and transport conditions) |
- |
5000 |
|
- |
| 8(Constructional and performance requirements) |
- |
180000 |
|
- |
| 8.1.1.2(Glow-wire testing) |
- |
10000 |
|
- |
| 8.1.1.3(Test based on flammability categor) |
- |
45000 |
|
- |
| 8.1.2(Current-carrying parts and their connections) |
- |
35000 |
|
- |
| 8.1.3(Clearances and creepage distances) |
- |
5000 |
|
- |
| 8.1.7.1(Constructional requirements) |
- |
45000 |
|
- |
| 8.1.9(Provisions for protective earthing) |
- |
35000 |
|
- |
| 8.1.10(Degree of protection) |
- |
45000 |
|
- |
| 8.1.11(Requirements for proximity switches with integrally connected cables) |
- |
65000 |
|
- |
| 8.2(Performance requirements) |
- |
125000 |
|
- |
| 8.2.2(Temperature-rise) |
- |
35000 |
|
- |
| 8.2.3(Dielectric properties) |
- |
25000 |
|
- |
| 8.2.3.2(Impulse withstand voltage) |
- |
65000 |
|
- |
| 8.2.4(Ability to make and break under normal load and abnormal load conditions) |
- |
125000 |
|
- |
| 8.2.5(Conditional short-circuit current) |
- |
125000 |
|
- |
| 8.3(Physical dimensions) |
- |
5000 |
|
- |
| 8.4(Shock and vibration and special environmental conditions) |
- |
65000 |
|
- |
| 9.2(Compliance with constructional requirements) |
- |
45000 |
|
- |
| 9.2.2.1(Test of resistance to abnormal heat and fire) |
- |
45000 |
|
- |
| 9.2.2.1.2(Flammability, hot wire ignition and arc ignition tests (on materials)) |
- |
85000 |
|
- |
| 9.3.3.4(Dielectric properties) |
- |
25000 |
|
- |
| 9.3.3.4.5(Impulse withstand voltage test) |
- |
35000 |
|
- |
| 9.3.3.5(Making and breaking capacities) |
- |
125000 |
|
- |
| B.9.1.2.3(Cable tests) |
- |
35000 |
|
- |
| B.9.1.2.4(Change of temperature test) |
- |
55000 |
|
- |
| B.9.1.2.5(Impact test) |
- |
25000 |
|
- |
| B.9.1.2.6(Damp heat, cyclic test) |
- |
75000 |
|
- |
| B.9.1.2.7(Dielectric test after stresses) |
- |
25000 |
|
- |
| C.9.1.2(Pull test) |
- |
25000 |
|
- |
| C.9.1.3(Torque test) |
- |
25000 |
|
- |
| C.9.1.4(Push test) |
- |
25000 |
|
- |
| C.9.1.5(Bend test) |
- |
15000 |
|
- |
| 9.3.4(Performance under short-circuit current conditions) |
- |
125000 |
|
- |
| 9.4(Testing of operating distances) |
- |
10000 |
|
- |
| 9.5(Testing for the frequency of operating cycles) |
- |
55000 |
|
- |
| 8.1.10(Degree of protection) |
- |
45000 |
|
- |
| 9.3.3.2(Operating limits) |
- |
125000 |
|
- |
| 9.3.3.3(Temperature-rise) |
- |
45000 |
|
- |
| E.8(Construction and performance requirements) |
- |
185000 |
|
- |
|
08 May, 2028 |
- Included w.e.f 26.12.2025
Exclusion: Cl. No. 8.4.1, Cl. No. 8.4.2, Cl. No. 9.4, Cl. No. 9.5, Cl. No. 8.2.6, Cl. No. 8.2.5, Cl. No. 9.3.4, Cl. No. E.9.1, Cl. No. 8.1.15 |
| 4451 |
Classic Instrumentation Pvt. Ltd. (8135126), Noida
| 8135126
| IS 16103 : Part 1 (2012) |
Led modules for general lighting: Part 1 safety requirements |
- |
40000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 7(Marking) |
- |
2000 |
|
- |
| 8(Terminals) |
- |
30000 |
|
- |
| 9(PROVISION FOR EARTHING) |
- |
3500 |
|
- |
| 10(Protection against accidental contact with live parts) |
- |
3500 |
|
- |
| 11(Mositure Resistance and Insulation) |
- |
4000 |
|
- |
| 12(Electric Strength) |
- |
3000 |
|
- |
| 13(Fault conditions) |
- |
3000 |
|
- |
| 15(Construction) |
- |
3000 |
|
- |
| 16(Creepage distance and clearances) |
- |
3000 |
|
- |
| 17(Screws, current carrying parts and connections) |
- |
3000 |
|
- |
| 18(Resistance to heat, fire and tracking) |
- |
3000 |
|
- |
| 19(Resistance to corrosion) |
- |
3000 |
|
- |
| 21(Heat management) |
- |
3000 |
|
- |
|
23 Oct, 2028 |
- Included w.e.f 16.07.2025 |
| 4452 |
Arihant Analytical Laboratory Pvt. Ltd., Sonipat
| 9167906
| IS 1660 (2024) |
Wrought and Cast Aluminium Utensils — Specification ( Second Revision ) |
All Type |
25000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl-3.1.1, 3.1.2(Minimum Thickness of Sheet) |
- |
25000 |
|
- |
| Cl-3.1.3, Table-2(Minimum Thickness at the Bottom) |
- |
25000 |
|
- |
| Cl-3.1.3, Table-2(Minimium Thickness of Wall at the Top Edge) |
- |
25000 |
|
- |
| Cl-3.1.3, Table-2(Minimum Cover Thickness) |
- |
25000 |
|
- |
| Cl-4.1(Main body of utensil) |
- |
25000 |
|
- |
| Cl-4.1(Cast cookware) |
- |
25000 |
|
- |
| Cl-4.1(Other aluminum components and parts) |
- |
25000 |
|
- |
| Cl-4.1.1(Lids (material)) |
- |
25000 |
|
- |
| Cl-4.1.1(Minimum thickness of lid) |
- |
25000 |
|
- |
| Cl-4.1.2(Minimum thickness of glass) |
- |
25000 |
|
- |
| Cl-4.1.2(Material of rim) |
- |
25000 |
|
- |
| Cl-4.1.2(Minimum thickness of rim) |
- |
25000 |
|
- |
| Cl-4.2(Material of strips) |
- |
25000 |
|
- |
| Cl-4.2(Stainless steel handles, rivets and fittings) |
- |
25000 |
|
- |
| Cl-4.3(Clips of lunch box) |
- |
25000 |
|
- |
| Cl-4.3(Clips of lunch box) |
- |
25000 |
|
- |
| Cl-4.3(Rivets used in lunch box) |
- |
25000 |
|
- |
| Cl-4.4(Screws, studs/nuts, and locking loop) |
- |
25000 |
|
- |
| Cl-4.5(Rivets for fixing of handles) |
- |
25000 |
|
- |
| Cl-4.5(Material of cap) |
- |
25000 |
|
- |
| Cl-4.6(Strips used for flame guards) |
- |
25000 |
|
- |
| Cl-4.6(stainless steel) |
- |
25000 |
|
- |
| Cl-5(Fabrication) |
- |
25000 |
|
- |
| Cl-6(Shape and Dimensions) |
- |
25000 |
|
- |
| Cl-7.1(Handles, when fitted) |
- |
25000 |
|
- |
| Cl-7.2(Handles) |
- |
25000 |
|
- |
| Cl-7.3 (Cl- 4.1 of IS 13395)(Construction) |
- |
25000 |
|
- |
| Cl-7.3 (Cl- 4.2 of IS 13395)(Materials) |
- |
25000 |
|
- |
| Cl-7.3 (Cl- 4.3 of IS 13395)(Selection and Size) |
- |
25000 |
|
- |
| Cl-7.3 (Cl- 4.4 of IS 13395)(Position of Handle and Knob with Respect to Cookware) |
- |
25000 |
|
- |
| Cl-7.3 (Cl- 4.5 of IS 13395)(Attachment to Cookware) |
- |
25000 |
|
- |
| Cl-7.3 (Cl- 5.2 of IS 13395)(Bending Strength) |
- |
25000 |
|
- |
| Cl-7.3 (Cl- 5.3 of IS 13395)(Torque Strength) |
- |
25000 |
|
- |
| Cl-7.3 (Cl- 5.4 of IS 13395)(Impact Strength) |
- |
25000 |
|
- |
| Cl-7.3 (Cl- 5.5 of IS 13395)(Fatigue Resistance) |
- |
25000 |
|
- |
| Cl-7.3 (Cl- 5.6 of IS 13395)(Leakage) |
- |
25000 |
|
- |
| Cl-7.3 (Cl- 5.7 of IS 13395)(Thermal Insulation) |
- |
25000 |
|
- |
| Wrought and Cast Aluminium Utensils — Specification(Heat Resistance) |
- |
25000 |
|
- |
| Cl-7.3 (Cl- 5.9 of IS 13395)(Washing Resistance (Type Test)) |
- |
25000 |
|
- |
| Cl-7.3 (Cl- 5.10 of IS 13395)(Burning Resistance) |
- |
25000 |
|
- |
| Cl-8(Workmanship and Finish) |
- |
25000 |
|
- |
| Cl-8.3(Utensils, if anodized, fully or partially) |
- |
25000 |
|
- |
| Cl-8.3(Minimum nominal thickness) |
- |
25000 |
|
- |
| Cl-8.3(Thickness of hard anodized) |
- |
25000 |
|
- |
| Cl-8.3(Finish and appearance of hard anodized) |
- |
25000 |
|
- |
| Cl-8.3(Abrasion resistance of hard anodized) |
- |
25000 |
|
- |
| Cl-8.3(Colour of hard anodized) |
- |
25000 |
|
- |
| Cl-8.3(Hardness of hard anodized) |
- |
25000 |
|
- |
| Wrought and Cast Aluminium Utensils — Specification(Lid of the cookware) |
- |
25000 |
|
- |
| Cl-8.5(Non-stick unreinforced PTFE) |
- |
25000 |
|
- |
| Cl-8.6(Ceramic coating) |
- |
25000 |
|
- |
| Cl-8.7(The thickness test, adhesion test) |
- |
25000 |
|
- |
| Cl-8.7(Minimum thickness of coating) |
- |
25000 |
|
- |
| Cl-8.7.1(Dry heat the cookware) |
- |
25000 |
|
- |
| Cl-8.8(Requirements of PTFE) |
- |
25000 |
|
- |
| Cl-8.9(Material for induction plate) |
- |
25000 |
|
- |
| Cl-8.9(Test for Induction compatible base) |
- |
25000 |
|
- |
| Cl-8.10.1(Tests for Lunch Boxes- Performance Test) |
- |
25000 |
|
- |
| Cl-8.10.1(Tests for Lunch Boxes- Performance Test) |
- |
25000 |
|
- |
| Cl-8.10.2(Tests for Lunch Boxes- Ground Nut Oil Test for Leakage) |
- |
25000 |
|
- |
| Cl-8.11.1(Test(s) on Tempered Glass Lid- Fragmentation Test) |
- |
25000 |
|
- |
| Cl-8.11.2(Test(s) on Tempered Glass Lid-Ball Drop Test) |
- |
25000 |
|
- |
| Cl-8.11.3(Test(s) on Tempered Glass Lid- Thermal Shock Test) |
- |
25000 |
|
- |
| Cl-8.11.4(Test(s) on Tempered Glass Lid- Free Fall Test) |
- |
25000 |
|
- |
| Cl-9.1(Normal Capacity) |
- |
25000 |
|
- |
| Cl-9.2(Normal Capacity of internal diameter) |
- |
25000 |
|
- |
|
02 Jun, 2027 |
- Included w.e.f.29.07.2025 |
| 4453 |
Br. MSME- DEVELOPMENT INSTITUTE, COIMBATORE
| 6105534
| IS 9283 (2024) |
LINE OPERATED A.C. MOTORS FOR SUBMERSIBLE PUMPSETS - SPECIFICATION (THIRD REVISION) |
Upto Rated Power of 15kW |
14700 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| As Per Clause 5.1.2 Table 1(Material) |
- |
14700 |
|
Up to 3.7 kW Rs.9000/- ;
Above 3.7kW & upto 7.5kW Rs.10900/- ;
Above 7.5kW & upto 11.0kW Rs.12700/- ;
Above 11.0kW & upto 15.0kW Rs.14700/- ; Testing Charges for complete IS. GST extra. Upto 15.0 kW only. |
| As Per Clause 5.1.3(Construction-General) |
- |
14700 |
|
Up to 3.7 kW Rs.9000/- ;
Above 3.7kW & upto 7.5kW Rs.10900/- ;
Above 7.5kW & upto 11.0kW Rs.12700/- ;
Above 11.0kW & upto 15.0kW Rs.14700/- ; Testing Charges for complete IS. GST extra. Upto 15.0 kW only. |
| As per Clause 5.1.4(Construction-General) |
- |
14700 |
|
Up to 3.7 kW Rs.9000/- ;
Above 3.7kW & upto 7.5kW Rs.10900/- ;
Above 7.5kW & upto 11.0kW Rs.12700/- ;
Above 11.0kW & upto 15.0kW Rs.14700/- ; Testing Charges for complete IS. GST extra. Upto 15.0 kW only. |
| As per Clause 5.2.1(Earthing) |
- |
14700 |
|
Up to 3.7 kW Rs.9000/- ;
Above 3.7kW & upto 7.5kW Rs.10900/- ;
Above 7.5kW & upto 11.0kW Rs.12700/- ;
Above 11.0kW & upto 15.0kW Rs.14700/- ; Testing Charges for complete IS. GST extra. Upto 15.0 kW only. |
| As per Clause 5.4.1(Construction-Type of cable & Size of conductor of cable) |
- |
14700 |
|
Up to 3.7 kW Rs.9000/- ;
Above 3.7kW & upto 7.5kW Rs.10900/- ;
Above 7.5kW & upto 11.0kW Rs.12700/- ;
Above 11.0kW & upto 15.0kW Rs.14700/- ; Testing Charges for complete IS. GST extra. Upto 15.0 kW only. |
| As per Clause 5.4.2(Construction-Length of cable) |
- |
14700 |
|
Up to 3.7 kW Rs.9000/- ;
Above 3.7kW & upto 7.5kW Rs.10900/- ;
Above 7.5kW & upto 11.0kW Rs.12700/- ;
Above 11.0kW & upto 15.0kW Rs.14700/- ; Testing Charges for complete IS. GST extra. Upto 15.0 kW only. |
| As per Clause 5.4.3(Construction-Joint in Cable) |
- |
14700 |
|
Up to 3.7 kW Rs.9000/- ;
Above 3.7kW & upto 7.5kW Rs.10900/- ;
Above 7.5kW & upto 11.0kW Rs.12700/- ;
Above 11.0kW & upto 15.0kW Rs.14700/- ; Testing Charges for complete IS. GST extra. Upto 15.0 kW only. |
| As per Clause 5.5(Finish of Bearings) |
- |
14700 |
|
Up to 3.7 kW Rs.9000/- ;
Above 3.7kW & upto 7.5kW Rs.10900/- ;
Above 7.5kW & upto 11.0kW Rs.12700/- ;
Above 11.0kW & upto 15.0kW Rs.14700/- ; Testing Charges for complete IS. GST extra. Upto 15.0 kW only. |
| As per Clause 5.6(Balancing of Rotor) |
- |
14700 |
|
Up to 3.7 kW Rs.9000/- ;
Above 3.7kW & upto 7.5kW Rs.10900/- ;
Above 7.5kW & upto 11.0kW Rs.12700/- ;
Above 11.0kW & upto 15.0kW Rs.14700/- ; Testing Charges for complete IS. GST extra. Upto 15.0 kW only. |
| As per Clause 7.1(Dimensions of Motors) |
- |
14700 |
|
Up to 3.7 kW Rs.9000/- ;
Above 3.7kW & upto 7.5kW Rs.10900/- ;
Above 7.5kW & upto 11.0kW Rs.12700/- ;
Above 11.0kW & upto 15.0kW Rs.14700/- ; Testing Charges for complete IS. GST extra. Upto 15.0 kW only. |
| As per Clause 7.2(Tolerances) |
- |
14700 |
|
Up to 3.7 kW Rs.9000/- ;
Above 3.7kW & upto 7.5kW Rs.10900/- ;
Above 7.5kW & upto 11.0kW Rs.12700/- ;
Above 11.0kW & upto 15.0kW Rs.14700/- ; Testing Charges for complete IS. GST extra. Upto 15.0 kW only. |
| As per Clause 12.1(Efficiency) |
- |
14700 |
|
Up to 3.7 kW Rs.9000/- ;
Above 3.7kW & upto 7.5kW Rs.10900/- ;
Above 7.5kW & upto 11.0kW Rs.12700/- ;
Above 11.0kW & upto 15.0kW Rs.14700/- ; Testing Charges for complete IS. GST extra. Upto 15.0 kW only. |
| As per Clause 12.1(Efficiency) |
- |
14700 |
|
Up to 3.7 kW Rs.9000/- ;
Above 3.7kW & upto 7.5kW Rs.10900/- ;
Above 7.5kW & upto 11.0kW Rs.12700/- ;
Above 11.0kW & upto 15.0kW Rs.14700/- ; Testing Charges for complete IS. GST extra. Upto 15.0 kW only. |
| As per Clause 13(Terminal Marking) |
- |
14700 |
|
Up to 3.7 kW Rs.9000/- ;
Above 3.7kW & upto 7.5kW Rs.10900/- ;
Above 7.5kW & upto 11.0kW Rs.12700/- ;
Above 11.0kW & upto 15.0kW Rs.14700/- ; Testing Charges for complete IS. GST extra. Upto 15.0 kW only. |
| As per Clause 15.1(Rating Plate) |
- |
14700 |
|
Up to 3.7 kW Rs.9000/- ;
Above 3.7kW & upto 7.5kW Rs.10900/- ;
Above 7.5kW & upto 11.0kW Rs.12700/- ;
Above 11.0kW & upto 15.0kW Rs.14700/- ; Testing Charges for complete IS. GST extra. Upto 15.0 kW only. |
| As per Clause 15.1(Rating Plate) |
- |
14700 |
|
Up to 3.7 kW Rs.9000/- ;
Above 3.7kW & upto 7.5kW Rs.10900/- ;
Above 7.5kW & upto 11.0kW Rs.12700/- ;
Above 11.0kW & upto 15.0kW Rs.14700/- ; Testing Charges for complete IS. GST extra. Upto 15.0 kW only. |
| As per Clause 15.1(Rating Plate) |
- |
14700 |
|
Up to 3.7 kW Rs.9000/- ;
Above 3.7kW & upto 7.5kW Rs.10900/- ;
Above 7.5kW & upto 11.0kW Rs.12700/- ;
Above 11.0kW & upto 15.0kW Rs.14700/- ; Testing Charges for complete IS. GST extra. Upto 15.0 kW only. |
| As per Clause 15.1(Rating Plate) |
- |
14700 |
|
Up to 3.7 kW Rs.9000/- ;
Above 3.7kW & upto 7.5kW Rs.10900/- ;
Above 7.5kW & upto 11.0kW Rs.12700/- ;
Above 11.0kW & upto 15.0kW Rs.14700/- ; Testing Charges for complete IS. GST extra. Upto 15.0 kW only. |
| As per Clause 15.1(Rating Plate) |
- |
14700 |
|
Up to 3.7 kW Rs.9000/- ;
Above 3.7kW & upto 7.5kW Rs.10900/- ;
Above 7.5kW & upto 11.0kW Rs.12700/- ;
Above 11.0kW & upto 15.0kW Rs.14700/- ; Testing Charges for complete IS. GST extra. Upto 15.0 kW only. |
| As per Clause 15.1(Rating Plate) |
- |
14700 |
|
Up to 3.7 kW Rs.9000/- ;
Above 3.7kW & upto 7.5kW Rs.10900/- ;
Above 7.5kW & upto 11.0kW Rs.12700/- ;
Above 11.0kW & upto 15.0kW Rs.14700/- ; Testing Charges for complete IS. GST extra. Upto 15.0 kW only. |
| As per Clause 15.1(Rating Plate) |
- |
14700 |
|
Up to 3.7 kW Rs.9000/- ;
Above 3.7kW & upto 7.5kW Rs.10900/- ;
Above 7.5kW & upto 11.0kW Rs.12700/- ;
Above 11.0kW & upto 15.0kW Rs.14700/- ; Testing Charges for complete IS. GST extra. Upto 15.0 kW only. |
| As per Clause 15.1(Rating Plate) |
- |
14700 |
|
Up to 3.7 kW Rs.9000/- ;
Above 3.7kW & upto 7.5kW Rs.10900/- ;
Above 7.5kW & upto 11.0kW Rs.12700/- ;
Above 11.0kW & upto 15.0kW Rs.14700/- ; Testing Charges for complete IS. GST extra. Upto 15.0 kW only. |
| As per Clause 15.1(Rating Plate) |
- |
14700 |
|
Up to 3.7 kW Rs.9000/- ;
Above 3.7kW & upto 7.5kW Rs.10900/- ;
Above 7.5kW & upto 11.0kW Rs.12700/- ;
Above 11.0kW & upto 15.0kW Rs.14700/- ; Testing Charges for complete IS. GST extra. Upto 15.0 kW only. |
| As per Clause 15.1(Rating Plate) |
- |
14700 |
|
Up to 3.7 kW Rs.9000/- ;
Above 3.7kW & upto 7.5kW Rs.10900/- ;
Above 7.5kW & upto 11.0kW Rs.12700/- ;
Above 11.0kW & upto 15.0kW Rs.14700/- ; Testing Charges for complete IS. GST extra. Upto 15.0 kW only. |
| As per Clause 15.1(Rating Plate) |
- |
14700 |
|
Up to 3.7 kW Rs.9000/- ;
Above 3.7kW & upto 7.5kW Rs.10900/- ;
Above 7.5kW & upto 11.0kW Rs.12700/- ;
Above 11.0kW & upto 15.0kW Rs.14700/- ; Testing Charges for complete IS. GST extra. Upto 15.0 kW only. |
| As per Clause 15.1(Rating Plate) |
- |
14700 |
|
Up to 3.7 kW Rs.9000/- ;
Above 3.7kW & upto 7.5kW Rs.10900/- ;
Above 7.5kW & upto 11.0kW Rs.12700/- ;
Above 11.0kW & upto 15.0kW Rs.14700/- ; Testing Charges for complete IS. GST extra. Upto 15.0 kW only. |
| As per Clause 15.1(Rating Plate) |
- |
14700 |
|
Up to 3.7 kW Rs.9000/- ;
Above 3.7kW & upto 7.5kW Rs.10900/- ;
Above 7.5kW & upto 11.0kW Rs.12700/- ;
Above 11.0kW & upto 15.0kW Rs.14700/- ; Testing Charges for complete IS. GST extra. Upto 15.0 kW only. |
| As per Clause 15.1(Rating Plate) |
- |
14700 |
|
Up to 3.7 kW Rs.9000/- ;
Above 3.7kW & upto 7.5kW Rs.10900/- ;
Above 7.5kW & upto 11.0kW Rs.12700/- ;
Above 11.0kW & upto 15.0kW Rs.14700/- ; Testing Charges for complete IS. GST extra. Upto 15.0 kW only. |
| As per Clause 15.1(Rating Plate) |
- |
14700 |
|
Up to 3.7 kW Rs.9000/- ;
Above 3.7kW & upto 7.5kW Rs.10900/- ;
Above 7.5kW & upto 11.0kW Rs.12700/- ;
Above 11.0kW & upto 15.0kW Rs.14700/- ; Testing Charges for complete IS. GST extra. Upto 15.0 kW only. |
| As per Clause 15.2(Rating Plate) |
- |
14700 |
|
Up to 3.7 kW Rs.9000/- ;
Above 3.7kW & upto 7.5kW Rs.10900/- ;
Above 7.5kW & upto 11.0kW Rs.12700/- ;
Above 11.0kW & upto 15.0kW Rs.14700/- ; Testing Charges for complete IS. GST extra. Upto 15.0 kW only. |
| As per Clause 16.1(a),21(Insulationresistance test(Before HV Test)) |
- |
14700 |
|
Up to 3.7 kW Rs.9000/- ;
Above 3.7kW & upto 7.5kW Rs.10900/- ;
Above 7.5kW & upto 11.0kW Rs.12700/- ;
Above 11.0kW & upto 15.0kW Rs.14700/- ; Testing Charges for complete IS. GST extra. Upto 15.0 kW only. |
| As per Clause 16.1(a),21(Insulationresistance test(After HV Test)) |
- |
14700 |
|
Up to 3.7 kW Rs.9000/- ;
Above 3.7kW & upto 7.5kW Rs.10900/- ;
Above 7.5kW & upto 11.0kW Rs.12700/- ;
Above 11.0kW & upto 15.0kW Rs.14700/- ; Testing Charges for complete IS. GST extra. Upto 15.0 kW only. |
| As per Clause 16.1(b),20(High voltage test) |
- |
14700 |
|
Up to 3.7 kW Rs.9000/- ;
Above 3.7kW & upto 7.5kW Rs.10900/- ;
Above 7.5kW & upto 11.0kW Rs.12700/- ;
Above 11.0kW & upto 15.0kW Rs.14700/- ; Testing Charges for complete IS. GST extra. Upto 15.0 kW only. |
| As per Clause 16.[c](Measurement of stator resistance) |
- |
14700 |
|
Up to 3.7 kW Rs.9000/- ;
Above 3.7kW & upto 7.5kW Rs.10900/- ;
Above 7.5kW & upto 11.0kW Rs.12700/- ;
Above 11.0kW & upto 15.0kW Rs.14700/- ; Testing Charges for complete IS. GST extra. Upto 15.0 kW only. |
| As per Clause 16.(d)(No Load Test) |
- |
14700 |
|
Up to 3.7 kW Rs.9000/- ;
Above 3.7kW & upto 7.5kW Rs.10900/- ;
Above 7.5kW & upto 11.0kW Rs.12700/- ;
Above 11.0kW & upto 15.0kW Rs.14700/- ; Testing Charges for complete IS. GST extra. Upto 15.0 kW only. |
| As per Clause 16.(e)(Reduced voltage running up test at no load) |
- |
14700 |
|
Up to 3.7 kW Rs.9000/- ;
Above 3.7kW & upto 7.5kW Rs.10900/- ;
Above 7.5kW & upto 11.0kW Rs.12700/- ;
Above 11.0kW & upto 15.0kW Rs.14700/- ; Testing Charges for complete IS. GST extra. Upto 15.0 kW only. |
| As per Clause 16.(f)(Locked rotor readings of voltage, current, power input and torque of motors) |
- |
14700 |
|
Up to 3.7 kW Rs.9000/- ;
Above 3.7kW & upto 7.5kW Rs.10900/- ;
Above 7.5kW & upto 11.0kW Rs.12700/- ;
Above 11.0kW & upto 15.0kW Rs.14700/- ; Testing Charges for complete IS. GST extra. Upto 15.0 kW only. |
| As per Clause 16.(g)(Full load reading of voltage, current, power input, speed and frequency) |
- |
14700 |
|
Up to 3.7 kW Rs.9000/- ;
Above 3.7kW & upto 7.5kW Rs.10900/- ;
Above 7.5kW & upto 11.0kW Rs.12700/- ;
Above 11.0kW & upto 15.0kW Rs.14700/- ; Testing Charges for complete IS. GST extra. Upto 15.0 kW only. |
| As per Clause 16.(h),11(Performance characteristics) |
- |
14700 |
|
Up to 3.7 kW Rs.9000/- ;
Above 3.7kW & upto 7.5kW Rs.10900/- ;
Above 7.5kW & upto 11.0kW Rs.12700/- ;
Above 11.0kW & upto 15.0kW Rs.14700/- ; Testing Charges for complete IS. GST extra. Upto 15.0 kW only. |
| As per Clause 16.(j),19(Temperature rise test at rated voltage) |
- |
14700 |
|
Up to 3.7 kW Rs.9000/- ;
Above 3.7kW & upto 7.5kW Rs.10900/- ;
Above 7.5kW & upto 11.0kW Rs.12700/- ;
Above 11.0kW & upto 15.0kW Rs.14700/- ; Testing Charges for complete IS. GST extra. Upto 15.0 kW only. |
| As per Clause 16.(k),19(Temperature rise test at reduced voltage) |
- |
14700 |
|
Up to 3.7 kW Rs.9000/- ;
Above 3.7kW & upto 7.5kW Rs.10900/- ;
Above 7.5kW & upto 11.0kW Rs.12700/- ;
Above 11.0kW & upto 15.0kW Rs.14700/- ; Testing Charges for complete IS. GST extra. Upto 15.0 kW only. |
| As per Clause 16.(m),18(Momentary Overload Test) |
- |
14700 |
|
Up to 3.7 kW Rs.9000/- ;
Above 3.7kW & upto 7.5kW Rs.10900/- ;
Above 7.5kW & upto 11.0kW Rs.12700/- ;
Above 11.0kW & upto 15.0kW Rs.14700/- ; Testing Charges for complete IS. GST extra. Upto 15.0 kW only. |
| As per Clause 16.(n),22(Leakage Current Test at rated voltage at no load) |
- |
14700 |
|
Up to 3.7 kW Rs.9000/- ;
Above 3.7kW & upto 7.5kW Rs.10900/- ;
Above 7.5kW & upto 11.0kW Rs.12700/- ;
Above 11.0kW & upto 15.0kW Rs.14700/- ; Testing Charges for complete IS. GST extra. Upto 15.0 kW only. |
| As Per Clause 5.1.2 Table 1(Material) |
- |
14700 |
|
Up to 3.7 kW Rs.9000/- ;
Above 3.7kW & upto 7.5kW Rs.10900/- ;
Above 7.5kW & upto 11.0kW Rs.12700/- ;
Above 11.0kW & upto 15.0kW Rs.14700/- ; Testing Charges for complete IS. GST extra. Upto 15.0 kW only. |
| As Per Clause 5.1.3(Construction-General) |
- |
14700 |
|
Up to 3.7 kW Rs.9000/- ;
Above 3.7kW & upto 7.5kW Rs.10900/- ;
Above 7.5kW & upto 11.0kW Rs.12700/- ;
Above 11.0kW & upto 15.0kW Rs.14700/- ; Testing Charges for complete IS. GST extra. Upto 15.0 kW only. |
| As per Clause 5.1.4(Construction-General) |
- |
14700 |
|
Up to 3.7 kW Rs.9000/- ;
Above 3.7kW & upto 7.5kW Rs.10900/- ;
Above 7.5kW & upto 11.0kW Rs.12700/- ;
Above 11.0kW & upto 15.0kW Rs.14700/- ; Testing Charges for complete IS. GST extra. Upto 15.0 kW only. |
| As per Clause 5.2.1(Earthing) |
- |
14700 |
|
Up to 3.7 kW Rs.9000/- ;
Above 3.7kW & upto 7.5kW Rs.10900/- ;
Above 7.5kW & upto 11.0kW Rs.12700/- ;
Above 11.0kW & upto 15.0kW Rs.14700/- ; Testing Charges for complete IS. GST extra. Upto 15.0 kW only. |
| As per Clause 5.4.1(Construction-Type of cable & Size of conductor of cable) |
- |
14700 |
|
Up to 3.7 kW Rs.9000/- ;
Above 3.7kW & upto 7.5kW Rs.10900/- ;
Above 7.5kW & upto 11.0kW Rs.12700/- ;
Above 11.0kW & upto 15.0kW Rs.14700/- ; Testing Charges for complete IS. GST extra. Upto 15.0 kW only. |
| As per Clause 5.4.2(Construction-Length of cable) |
- |
14700 |
|
Up to 3.7 kW Rs.9000/- ;
Above 3.7kW & upto 7.5kW Rs.10900/- ;
Above 7.5kW & upto 11.0kW Rs.12700/- ;
Above 11.0kW & upto 15.0kW Rs.14700/- ; Testing Charges for complete IS. GST extra. Upto 15.0 kW only. |
| As per Clause 5.4.3(Construction-Joint in Cable) |
- |
14700 |
|
Up to 3.7 kW Rs.9000/- ;
Above 3.7kW & upto 7.5kW Rs.10900/- ;
Above 7.5kW & upto 11.0kW Rs.12700/- ;
Above 11.0kW & upto 15.0kW Rs.14700/- ; Testing Charges for complete IS. GST extra. Upto 15.0 kW only. |
| As per Clause 5.5(Finish of Bearings) |
- |
14700 |
|
Up to 3.7 kW Rs.9000/- ;
Above 3.7kW & upto 7.5kW Rs.10900/- ;
Above 7.5kW & upto 11.0kW Rs.12700/- ;
Above 11.0kW & upto 15.0kW Rs.14700/- ; Testing Charges for complete IS. GST extra. Upto 15.0 kW only. |
| As per Clause 5.6(Balancing of Rotor) |
- |
14700 |
|
Up to 3.7 kW Rs.9000/- ;
Above 3.7kW & upto 7.5kW Rs.10900/- ;
Above 7.5kW & upto 11.0kW Rs.12700/- ;
Above 11.0kW & upto 15.0kW Rs.14700/- ; Testing Charges for complete IS. GST extra. Upto 15.0 kW only. |
| As per Clause 7.1(Dimensions of Motors) |
- |
14700 |
|
Up to 3.7 kW Rs.9000/- ;
Above 3.7kW & upto 7.5kW Rs.10900/- ;
Above 7.5kW & upto 11.0kW Rs.12700/- ;
Above 11.0kW & upto 15.0kW Rs.14700/- ; Testing Charges for complete IS. GST extra. Upto 15.0 kW only. |
| As per Clause 7.2(Tolerances) |
- |
14700 |
|
Up to 3.7 kW Rs.9000/- ;
Above 3.7kW & upto 7.5kW Rs.10900/- ;
Above 7.5kW & upto 11.0kW Rs.12700/- ;
Above 11.0kW & upto 15.0kW Rs.14700/- ; Testing Charges for complete IS. GST extra. Upto 15.0 kW only. |
| As per Clause 12.1(Efficiency) |
- |
14700 |
|
Up to 3.7 kW Rs.9000/- ;
Above 3.7kW & upto 7.5kW Rs.10900/- ;
Above 7.5kW & upto 11.0kW Rs.12700/- ;
Above 11.0kW & upto 15.0kW Rs.14700/- ; Testing Charges for complete IS. GST extra. Upto 15.0 kW only. |
| As per Clause 12.1(Efficiency) |
- |
14700 |
|
Up to 3.7 kW Rs.9000/- ;
Above 3.7kW & upto 7.5kW Rs.10900/- ;
Above 7.5kW & upto 11.0kW Rs.12700/- ;
Above 11.0kW & upto 15.0kW Rs.14700/- ; Testing Charges for complete IS. GST extra. Upto 15.0 kW only. |
| As per Clause 13(Terminal Marking) |
- |
14700 |
|
Up to 3.7 kW Rs.9000/- ;
Above 3.7kW & upto 7.5kW Rs.10900/- ;
Above 7.5kW & upto 11.0kW Rs.12700/- ;
Above 11.0kW & upto 15.0kW Rs.14700/- ; Testing Charges for complete IS. GST extra. Upto 15.0 kW only. |
| As per Clause 15.1(Rating Plate) |
- |
14700 |
|
Up to 3.7 kW Rs.9000/- ;
Above 3.7kW & upto 7.5kW Rs.10900/- ;
Above 7.5kW & upto 11.0kW Rs.12700/- ;
Above 11.0kW & upto 15.0kW Rs.14700/- ; Testing Charges for complete IS. GST extra. Upto 15.0 kW only. |
| As per Clause 15.1(Rating Plate) |
- |
14700 |
|
Up to 3.7 kW Rs.9000/- ;
Above 3.7kW & upto 7.5kW Rs.10900/- ;
Above 7.5kW & upto 11.0kW Rs.12700/- ;
Above 11.0kW & upto 15.0kW Rs.14700/- ; Testing Charges for complete IS. GST extra. Upto 15.0 kW only. |
| As per Clause 15.1(Rating Plate) |
- |
14700 |
|
Up to 3.7 kW Rs.9000/- ;
Above 3.7kW & upto 7.5kW Rs.10900/- ;
Above 7.5kW & upto 11.0kW Rs.12700/- ;
Above 11.0kW & upto 15.0kW Rs.14700/- ; Testing Charges for complete IS. GST extra. Upto 15.0 kW only. |
| As per Clause 15.1(Rating Plate) |
- |
14700 |
|
Up to 3.7 kW Rs.9000/- ;
Above 3.7kW & upto 7.5kW Rs.10900/- ;
Above 7.5kW & upto 11.0kW Rs.12700/- ;
Above 11.0kW & upto 15.0kW Rs.14700/- ; Testing Charges for complete IS. GST extra. Upto 15.0 kW only. |
| As per Clause 15.1(Rating Plate) |
- |
14700 |
|
Up to 3.7 kW Rs.9000/- ;
Above 3.7kW & upto 7.5kW Rs.10900/- ;
Above 7.5kW & upto 11.0kW Rs.12700/- ;
Above 11.0kW & upto 15.0kW Rs.14700/- ; Testing Charges for complete IS. GST extra. Upto 15.0 kW only. |
| As per Clause 15.1(Rating Plate) |
- |
14700 |
|
Up to 3.7 kW Rs.9000/- ;
Above 3.7kW & upto 7.5kW Rs.10900/- ;
Above 7.5kW & upto 11.0kW Rs.12700/- ;
Above 11.0kW & upto 15.0kW Rs.14700/- ; Testing Charges for complete IS. GST extra. Upto 15.0 kW only. |
| As per Clause 15.1(Rating Plate) |
- |
14700 |
|
Up to 3.7 kW Rs.9000/- ;
Above 3.7kW & upto 7.5kW Rs.10900/- ;
Above 7.5kW & upto 11.0kW Rs.12700/- ;
Above 11.0kW & upto 15.0kW Rs.14700/- ; Testing Charges for complete IS. GST extra. Upto 15.0 kW only. |
| As per Clause 15.1(Rating Plate) |
- |
14700 |
|
Up to 3.7 kW Rs.9000/- ;
Above 3.7kW & upto 7.5kW Rs.10900/- ;
Above 7.5kW & upto 11.0kW Rs.12700/- ;
Above 11.0kW & upto 15.0kW Rs.14700/- ; Testing Charges for complete IS. GST extra. Upto 15.0 kW only. |
| As per Clause 15.1(Rating Plate) |
- |
14700 |
|
Up to 3.7 kW Rs.9000/- ;
Above 3.7kW & upto 7.5kW Rs.10900/- ;
Above 7.5kW & upto 11.0kW Rs.12700/- ;
Above 11.0kW & upto 15.0kW Rs.14700/- ; Testing Charges for complete IS. GST extra. Upto 15.0 kW only. |
| As per Clause 15.1(Rating Plate) |
- |
14700 |
|
Up to 3.7 kW Rs.9000/- ;
Above 3.7kW & upto 7.5kW Rs.10900/- ;
Above 7.5kW & upto 11.0kW Rs.12700/- ;
Above 11.0kW & upto 15.0kW Rs.14700/- ; Testing Charges for complete IS. GST extra. Upto 15.0 kW only. |
| As per Clause 15.1(Rating Plate) |
- |
14700 |
|
Up to 3.7 kW Rs.9000/- ;
Above 3.7kW & upto 7.5kW Rs.10900/- ;
Above 7.5kW & upto 11.0kW Rs.12700/- ;
Above 11.0kW & upto 15.0kW Rs.14700/- ; Testing Charges for complete IS. GST extra. Upto 15.0 kW only. |
| As per Clause 15.1(Rating Plate) |
- |
14700 |
|
Up to 3.7 kW Rs.9000/- ;
Above 3.7kW & upto 7.5kW Rs.10900/- ;
Above 7.5kW & upto 11.0kW Rs.12700/- ;
Above 11.0kW & upto 15.0kW Rs.14700/- ; Testing Charges for complete IS. GST extra. Upto 15.0 kW only. |
| As per Clause 15.1(Rating Plate) |
- |
14700 |
|
Up to 3.7 kW Rs.9000/- ;
Above 3.7kW & upto 7.5kW Rs.10900/- ;
Above 7.5kW & upto 11.0kW Rs.12700/- ;
Above 11.0kW & upto 15.0kW Rs.14700/- ; Testing Charges for complete IS. GST extra. Upto 15.0 kW only. |
| As per Clause 15.1(Rating Plate) |
- |
14700 |
|
Up to 3.7 kW Rs.9000/- ;
Above 3.7kW & upto 7.5kW Rs.10900/- ;
Above 7.5kW & upto 11.0kW Rs.12700/- ;
Above 11.0kW & upto 15.0kW Rs.14700/- ; Testing Charges for complete IS. GST extra. Upto 15.0 kW only. |
| As per Clause 15.1(Rating Plate) |
- |
14700 |
|
Up to 3.7 kW Rs.9000/- ;
Above 3.7kW & upto 7.5kW Rs.10900/- ;
Above 7.5kW & upto 11.0kW Rs.12700/- ;
Above 11.0kW & upto 15.0kW Rs.14700/- ; Testing Charges for complete IS. GST extra. Upto 15.0 kW only. |
| As per Clause 15.2(Rating Plate) |
- |
14700 |
|
Up to 3.7 kW Rs.9000/- ;
Above 3.7kW & upto 7.5kW Rs.10900/- ;
Above 7.5kW & upto 11.0kW Rs.12700/- ;
Above 11.0kW & upto 15.0kW Rs.14700/- ; Testing Charges for complete IS. GST extra. Upto 15.0 kW only. |
| As per Clause 16.1(a),21(Insulationresistance test(Before HV Test)) |
- |
14700 |
|
Up to 3.7 kW Rs.9000/- ;
Above 3.7kW & upto 7.5kW Rs.10900/- ;
Above 7.5kW & upto 11.0kW Rs.12700/- ;
Above 11.0kW & upto 15.0kW Rs.14700/- ; Testing Charges for complete IS. GST extra. Upto 15.0 kW only. |
| As per Clause 16.1(a),21(Insulationresistance test(After HV Test)) |
- |
14700 |
|
Up to 3.7 kW Rs.9000/- ;
Above 3.7kW & upto 7.5kW Rs.10900/- ;
Above 7.5kW & upto 11.0kW Rs.12700/- ;
Above 11.0kW & upto 15.0kW Rs.14700/- ; Testing Charges for complete IS. GST extra. Upto 15.0 kW only. |
| As per Clause 16.1(b),20(High voltage test) |
- |
14700 |
|
Up to 3.7 kW Rs.9000/- ;
Above 3.7kW & upto 7.5kW Rs.10900/- ;
Above 7.5kW & upto 11.0kW Rs.12700/- ;
Above 11.0kW & upto 15.0kW Rs.14700/- ; Testing Charges for complete IS. GST extra. Upto 15.0 kW only. |
| As per Clause 16.[c](Measurement of stator resistance) |
- |
14700 |
|
Up to 3.7 kW Rs.9000/- ;
Above 3.7kW & upto 7.5kW Rs.10900/- ;
Above 7.5kW & upto 11.0kW Rs.12700/- ;
Above 11.0kW & upto 15.0kW Rs.14700/- ; Testing Charges for complete IS. GST extra. Upto 15.0 kW only. |
| As per Clause 16.(d)(No Load Test) |
- |
14700 |
|
Up to 3.7 kW Rs.9000/- ;
Above 3.7kW & upto 7.5kW Rs.10900/- ;
Above 7.5kW & upto 11.0kW Rs.12700/- ;
Above 11.0kW & upto 15.0kW Rs.14700/- ; Testing Charges for complete IS. GST extra. Upto 15.0 kW only. |
| As per Clause 16.(e)(Reduced voltage running up test at no load) |
- |
14700 |
|
Up to 3.7 kW Rs.9000/- ;
Above 3.7kW & upto 7.5kW Rs.10900/- ;
Above 7.5kW & upto 11.0kW Rs.12700/- ;
Above 11.0kW & upto 15.0kW Rs.14700/- ; Testing Charges for complete IS. GST extra. Upto 15.0 kW only. |
| As per Clause 16.(f)(Locked rotor readings of voltage, current, power input and torque of motors) |
- |
14700 |
|
Up to 3.7 kW Rs.9000/- ;
Above 3.7kW & upto 7.5kW Rs.10900/- ;
Above 7.5kW & upto 11.0kW Rs.12700/- ;
Above 11.0kW & upto 15.0kW Rs.14700/- ; Testing Charges for complete IS. GST extra. Upto 15.0 kW only. |
| As per Clause 16.(g)(Full load reading of voltage, current, power input, speed and frequency) |
- |
14700 |
|
Up to 3.7 kW Rs.9000/- ;
Above 3.7kW & upto 7.5kW Rs.10900/- ;
Above 7.5kW & upto 11.0kW Rs.12700/- ;
Above 11.0kW & upto 15.0kW Rs.14700/- ; Testing Charges for complete IS. GST extra. Upto 15.0 kW only. |
| As per Clause 16.(h),11(Performance characteristics) |
- |
14700 |
|
Up to 3.7 kW Rs.9000/- ;
Above 3.7kW & upto 7.5kW Rs.10900/- ;
Above 7.5kW & upto 11.0kW Rs.12700/- ;
Above 11.0kW & upto 15.0kW Rs.14700/- ; Testing Charges for complete IS. GST extra. Upto 15.0 kW only. |
| As per Clause 16.(j),19(Temperature rise test at rated voltage) |
- |
14700 |
|
Up to 3.7 kW Rs.9000/- ;
Above 3.7kW & upto 7.5kW Rs.10900/- ;
Above 7.5kW & upto 11.0kW Rs.12700/- ;
Above 11.0kW & upto 15.0kW Rs.14700/- ; Testing Charges for complete IS. GST extra. Upto 15.0 kW only. |
| As per Clause 16.(k),19(Temperature rise test at reduced voltage) |
- |
14700 |
|
Up to 3.7 kW Rs.9000/- ;
Above 3.7kW & upto 7.5kW Rs.10900/- ;
Above 7.5kW & upto 11.0kW Rs.12700/- ;
Above 11.0kW & upto 15.0kW Rs.14700/- ; Testing Charges for complete IS. GST extra. Upto 15.0 kW only. |
| As per Clause 16.(m),18(Momentary Overload Test) |
- |
14700 |
|
Up to 3.7 kW Rs.9000/- ;
Above 3.7kW & upto 7.5kW Rs.10900/- ;
Above 7.5kW & upto 11.0kW Rs.12700/- ;
Above 11.0kW & upto 15.0kW Rs.14700/- ; Testing Charges for complete IS. GST extra. Upto 15.0 kW only. |
| As per Clause 16.(n),22(Leakage Current Test at rated voltage at no load) |
- |
14700 |
|
Up to 3.7 kW Rs.9000/- ;
Above 3.7kW & upto 7.5kW Rs.10900/- ;
Above 7.5kW & upto 11.0kW Rs.12700/- ;
Above 11.0kW & upto 15.0kW Rs.14700/- ; Testing Charges for complete IS. GST extra. Upto 15.0 kW only. |
| As Per Clause 5.1.2 Table 1(Material) |
- |
- |
|
- |
| As Per Clause 5.1.3(Construction-General) |
- |
- |
|
- |
| As per Clause 5.1.4(Construction-General) |
- |
- |
|
- |
| As per Clause 5.2.1(Earthing) |
- |
- |
|
- |
| As per Clause 5.4.1(Construction-Type of cable & Size of conductor of cable) |
- |
- |
|
- |
| As per Clause 5.4.2(Construction-Length of cable) |
- |
- |
|
- |
| As per Clause 5.4.3(Construction-Joint in Cable) |
- |
- |
|
- |
| As per Clause 5.5(Finish of Bearings) |
- |
- |
|
- |
| As per Clause 5.6(Balancing of Rotor) |
- |
- |
|
- |
| As per Clause 7.1(Dimensions of Motors) |
- |
- |
|
- |
| As per Clause 7.2(Tolerances) |
- |
- |
|
- |
| As per Clause 12.1(Efficiency) |
- |
- |
|
- |
| As per Clause 12.1(Efficiency) |
- |
- |
|
- |
| As per Clause 13(Terminal Marking) |
- |
- |
|
- |
| As per Clause 15.1(Rating Plate) |
- |
- |
|
- |
| As per Clause 15.1(Rating Plate) |
- |
- |
|
- |
| As per Clause 15.1(Rating Plate) |
- |
- |
|
- |
| As per Clause 15.1(Rating Plate) |
- |
- |
|
- |
| As per Clause 15.1(Rating Plate) |
- |
- |
|
- |
| As per Clause 15.1(Rating Plate) |
- |
- |
|
- |
| As per Clause 15.1(Rating Plate) |
- |
- |
|
- |
| As per Clause 15.1(Rating Plate) |
- |
- |
|
- |
| As per Clause 15.1(Rating Plate) |
- |
- |
|
- |
| As per Clause 15.1(Rating Plate) |
- |
- |
|
- |
| As per Clause 15.1(Rating Plate) |
- |
- |
|
- |
| As per Clause 15.1(Rating Plate) |
- |
- |
|
- |
| As per Clause 15.1(Rating Plate) |
- |
- |
|
- |
| As per Clause 15.1(Rating Plate) |
- |
- |
|
- |
| As per Clause 15.1(Rating Plate) |
- |
- |
|
- |
| As per Clause 15.2(Rating Plate) |
- |
- |
|
- |
| As per Clause 16.1(a),21(Insulationresistance test(Before HV Test)) |
- |
- |
|
- |
| As per Clause 16.1(a),21(Insulationresistance test(After HV Test)) |
- |
- |
|
- |
| As per Clause 16.1(b),20(High voltage test) |
- |
- |
|
- |
| As per Clause 16.[c](Measurement of stator resistance) |
- |
- |
|
- |
| As per Clause 16.(d)(No Load Test) |
- |
- |
|
- |
| As per Clause 16.(e)(Reduced voltage running up test at no load) |
- |
- |
|
- |
| As per Clause 16.(f)(Locked rotor readings of voltage, current, power input and torque of motors) |
- |
- |
|
- |
| As per Clause 16.(g)(Full load reading of voltage, current, power input, speed and frequency) |
- |
- |
|
- |
| As per Clause 16.(h),11(Performance characteristics) |
- |
- |
|
- |
| As per Clause 16.(j),19(Temperature rise test at rated voltage) |
- |
- |
|
- |
| As per Clause 16.(k),19(Temperature rise test at reduced voltage) |
- |
- |
|
- |
| As per Clause 16.(m),18(Momentary Overload Test) |
- |
- |
|
- |
| As per Clause 16.(n),22(Leakage Current Test at rated voltage at no load) |
- |
- |
|
- |
|
14 Jan, 2028 |
- Included w.e.f. 18.08.2025 |
| 4454 |
Institute for Auto Parts and Hand Tools Technology, Ludhiana
| 9126034
| IS 4003 : Part 1 (2024) |
Pipe Wrenches - Specification Part 1 General Purpose(Second revision) |
All Grade / Type / Size / Designation as per IS 4003 (Pt-1): 2024 |
15570 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Clause. 4.0(Dimensions) |
- |
1200 |
|
- |
| Clause.5.0(Carbon) |
- |
100 |
|
- |
| Clause.5.0(Sulphur) |
- |
100 |
|
- |
| Clause.5.0(Phosphorus) |
- |
100 |
|
- |
| Clause.5.0(Niobium) |
- |
0 |
|
- |
| Clause.5.0(Vanadium) |
- |
120 |
|
- |
| Clause.5.0(Nickel) |
- |
0 |
|
- |
| Clause.5.0(Molybdenum) |
- |
0 |
|
- |
| Clause.5.0(Chromium) |
- |
120 |
|
- |
| Clause.5.0(Silicon) |
- |
100 |
|
- |
| Clause.5.0(Manganese) |
- |
100 |
|
- |
| Clause.6.0(Hardness) |
- |
400 |
|
- |
| Clause.7.0(Manufacture) |
- |
0 |
|
- |
| Clause.7.1(Handle) |
- |
0 |
|
- |
| Clause.7.2(Movable Jaws) |
- |
0 |
|
- |
| Clause.7.3(Adjusting Nut) |
- |
0 |
|
- |
| Clause.7.4(Frame) |
- |
8730 |
|
Test as per IS 1865
Mech. Properties=3900/- + Impact tests= 4000/- + Brinell Hardness Test= 250 = 8730/-
Test as per IS 14329
Freedom from defect= 580/-
Mech. Properties = 3900/-
Brinell Hardness = 250
Total= 4730 |
| Clause.7.5(Hinge Pin) |
- |
0 |
|
- |
| Clause.7.6(Spring) |
- |
0 |
|
- |
| Clause.8.0(Workmanship & finish) |
- |
500 |
|
- |
| Clause.9.0(Operation) |
- |
0 |
|
- |
| Clause.10.0(Sampling) |
- |
0 |
|
- |
| Clause.11.0(Tests) |
- |
0 |
|
- |
| Clause.11.1(Static Load Test) |
- |
2000 |
|
- |
| Clause.11.2(Static-Shock Load Test) |
- |
2000 |
|
- |
| Clause.12.0(Designation) |
- |
0 |
|
- |
| Clause.13(Marking) |
- |
0 |
|
-15570 |
|
17 Feb, 2028 |
- Included w.e.f.28.07.2025 |
| 4455 |
Planet Electro Labs Private Limited, Wazirpur
| 8185226
| IS/IEC 60947 : Part 5 : Sec 1 (2016) |
Low-Voltage Switchgear And Control Gear : Part 5-1 Control Circuit Devices And Switching Elements Electromechanical Control Circuit Devices |
- |
2500000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 5.2.1(Marking : General
") |
- |
5000 |
|
- |
| 5.2.2(Terminal identification and marking) |
- |
5000 |
|
- |
| 5.2.3(Functional markings) |
- |
5000 |
|
- |
| 5.2.4(Emergency stop) |
- |
5000 |
|
- |
| 5.2.5(Operating diagram) |
- |
5000 |
|
- |
| 5.2.5.1(Position indication) |
- |
5000 |
|
- |
| 5.2.5.2(Terminal markings for operating diagrams) |
- |
5000 |
|
- |
| 5.2.6(Time delay markings) |
- |
5000 |
|
- |
| 5.3(Instructions for installation, operation and maintenance) |
- |
5000 |
|
- |
| 7.1.2.2(Glow-wire testing) |
- |
10000 |
|
- |
| 7.1.3(Current-carrying parts and their connections) |
- |
15000 |
|
- |
| 7.1.4(Clearances and creepage distances) |
- |
5000 |
|
- |
| 7.2.4.1(Making and breaking capacities) |
- |
115000 |
|
- |
| 7.2.4.3(Durability) |
- |
45000 |
|
- |
| 7.2.3(Dielectric properties) |
- |
25000 |
|
- |
| 8.1.5(Special tests) |
- |
25000 |
|
- |
| 8.2.1.1(Test of resistance to abnormal heat and fire) |
- |
35000 |
|
- |
| 8.2.1.1.1(Glow-wire test) |
- |
10000 |
|
- |
| 8.2.1.1.2(Flammability, hot wire ignition and arc ignition tests (on materials)) |
- |
85000 |
|
- |
| 8.2.3(Enclosures for equipment) |
- |
45000 |
|
- |
| 8.2.4(Mechanical and electrical properties of terminals) |
- |
45000 |
|
- |
| 8.2.4.2(Tests of mechanical strength of terminals) |
- |
45000 |
|
- |
| 8.2.4.3(Testing for damage to and accidental loosening of conductors (flexion test)) |
- |
35000 |
|
- |
| 8.2.4.4(Pull-out test) |
- |
25000 |
|
- |
| 8.2.4.5(Test for insertability of unprepared round copper conductors having the maximum cross-section) |
- |
35000 |
|
- |
| 8.2.5(Verification of actuating force (or moment)) |
- |
35000 |
|
- |
| 8.2.6(Verification of limitation of rotation (of a rotary switch)) |
- |
35000 |
|
- |
| 8.2.7(Conduit pull-out test, torque test, and bending test with metallic conduits) |
- |
45000 |
|
- |
| 8.3.3.3(Temperature rise) |
- |
65000 |
|
- |
| 8.3.3.4(Dielectric properties) |
- |
25000 |
|
- |
| 8.3.3.2(Operating limits of contactor relays) |
- |
35000 |
|
- |
| 8.3.3.5(Making and breaking capacities) |
- |
115000 |
|
- |
| 8.3.3.5.2(Test circuits and connections) |
- |
65000 |
|
- |
| 8.3.4.3(Test circuit and test quantities) |
- |
45000 |
|
- |
| 8.3.4.2(Performance under conditional short-circuit current : Test procedure) |
- |
115000 |
|
- |
| 8.3.4.1(General conditions for short-circuit tests) |
- |
1200000 |
|
- |
| 8.3.4.4 b)(Condition of the switching element after the test) |
- |
35000 |
|
- |
| 8.3.4.4 a)(Condition of the switching element after the test) |
- |
35000 |
|
- |
| 8.4.2.4(Surges) |
- |
0 |
|
- |
| 8.3.1(Degree of protection of enclosed control circuit devices) |
- |
45000 |
|
- |
| C.3(Electrical durability) |
- |
65000 |
|
- |
| C.2(Mechanical durability) |
- |
35000 |
|
- |
| C.1.2(Observation) |
- |
5000 |
|
- |
| F 8.1.2.6("Dielectric test
after stresses") |
- |
25000 |
|
- |
| F 8.1.2.4(Impact test) |
- |
35000 |
|
- |
| F.8.1.2.3("Rapid change of temperature
test") |
- |
35000 |
|
- |
| F.8.1.2.5(Damp heat, cyclic) |
- |
65000 |
|
- |
| F.8.1.2.4(Impact test) |
- |
35000 |
|
- |
| F.8.1.2.1(Dielectric tests in new conditions) |
- |
25000 |
|
- |
| G.8.2.5(Bend test) |
- |
25000 |
|
- |
| G.8.2.4(Push test) |
- |
25000 |
|
- |
| G.8.2.3(Torque test) |
- |
25000 |
|
- |
| G.8.2.2(Pull-out test) |
- |
35000 |
|
- |
| H.8.6("Performance under short circuit current
conditions") |
- |
115000 |
|
- |
| H.8.5("Making and
breaking
capacities") |
- |
115000 |
|
- |
| H.8.4(OFF-state current) |
- |
35000 |
|
- |
| H.8.2(Voltage drop test) |
- |
25000 |
|
- |
| J.8.5("Degree of
protection for
indicating towers") |
- |
45000 |
|
- |
| J.8.4.3(Indirect support mounting) |
- |
35000 |
|
- |
| J.8.4.2.3(Vibration) |
- |
25000 |
|
- |
| J.8.4.2.2(Shock) |
- |
25000 |
|
- |
| J.8.3.4("Short Circuit test
(on built-in
transformers, if
any)") |
- |
115000 |
|
- |
| J.8.3.3.3(Temp-rise tests) |
- |
115000 |
|
- |
| J.8.3.3.4.3("Dielectric test
(indicator lights
with built-in
transformers)") |
- |
25000 |
|
- |
| J.8.3.3.4(Dielectric test) |
- |
25000 |
|
- |
| J.7.1.12(Indicator lights with built-in transformers) |
- |
15000 |
|
- |
| J.7("Constructional
requirements") |
- |
45000 |
|
- |
| K 8.3.4("Performance under
conditional shortcircuit current") |
- |
115000 |
|
- |
| K 8.3.7(Verification of robustness of the actuating system) |
- |
35000 |
|
- |
| K 8.3.5(Verification of mechanical operation of position switches at limits of temperature) |
- |
35000 |
|
- |
| K.8.3.6(Verification of direct opening action) |
- |
35000 |
|
- |
| L.8.4(Special test for mechanically linked contact elements) |
- |
45000 |
|
- |
| N.3(Method based on durability test results) |
- |
35000 |
|
- |
| L.8.4(Special test for mechanically linked contact elements) |
- |
45000 |
|
- |
| K.8.3.6(Verification of direct opening action) |
- |
35000 |
|
- |
| 5.2.1(" Marking : General
") |
- |
5000 |
|
- |
| K 8.3.5(Verification of mechanical operation of position switches at limits of temperature) |
- |
45000 |
|
- |
| K 8.3.7(Verification of robustness of the actuating system) |
- |
25000 |
|
- |
| K 8.3.4("Performance under
conditional shortcircuit current") |
- |
115000 |
|
- |
| 5.2.2(Terminal identification and marking) |
- |
5000 |
|
- |
| J.7("Constructional
requirements") |
- |
35000 |
|
- |
| 5.2.3(Functional markings) |
- |
5000 |
|
- |
| J.7.1.12(Indicator lights with built-in transformers) |
- |
5000 |
|
- |
| J.8.3.3.4(Dielectric test) |
- |
25000 |
|
- |
| 5.2.4(Emergency stop) |
- |
35000 |
|
- |
| J.8.3.3.4.3("Dielectric test
(indicator lights
with built-in
transformers)") |
- |
25000 |
|
- |
| J.8.3.3.3(Temp-rise tests) |
- |
35000 |
|
- |
| J.8.3.4("Short Circuit test
(on built-in
transformers, if
any)") |
- |
115000 |
|
- |
| 5.2.5(Operating diagram) |
- |
5000 |
|
- |
| J.8.4.2.2(Shock) |
- |
30000 |
|
- |
| 5.2.5.1(Position indication) |
- |
5000 |
|
- |
| J.8.4.2.3(Vibration) |
- |
32000 |
|
- |
| J.8.4.3(Indirect support mounting) |
- |
5000 |
|
- |
| 5.2.5.2(Terminal markings for operating diagrams) |
- |
5000 |
|
- |
| J.8.5("Degree of
protection for
indicating towers") |
- |
35000 |
|
- |
| 5.2.6(Time delay markings) |
- |
5000 |
|
- |
| H.8.2(Voltage drop test) |
- |
25000 |
|
- |
| 5.3(Instructions for installation, operation and maintenance) |
- |
5000 |
|
- |
| H.8.4(OFF-state current) |
- |
35000 |
|
- |
| H.8.5("Making and
breaking
capacities") |
- |
115000 |
|
- |
| 7.1.2.2(Glow-wire testing) |
- |
10000 |
|
- |
| H.8.6("Performance under short circuit current
conditions") |
- |
125000 |
|
- |
| 7.1.3(Current-carrying parts and their connections) |
- |
35000 |
|
- |
| G.8.2.2(Pull-out test) |
- |
25000 |
|
- |
| 7.1.4 of IEC 60947-1:2007 (Sequence 6)(Measurement of Clearances and creepage distances) |
- |
5000 |
|
- |
| G.8.2.3(Torque test) |
- |
15000 |
|
- |
| 7.2.4.1(Making and breaking capacities) |
- |
115000 |
|
- |
| 7.2.4.1(Making and breaking capacities) |
- |
115000 |
|
- |
| G.8.2.4(Push test) |
- |
5000 |
|
- |
| G.8.2.5(Bend test) |
- |
15000 |
|
- |
| F.8.1.2.1(Dielectric tests in new conditions) |
- |
25000 |
|
- |
| 7.2.4.3(Durability) |
- |
25000 |
|
- |
| F.8.1.2.4(Impact test) |
- |
25000 |
|
- |
| F.8.1.2.5(Damp heat, cyclic) |
- |
65000 |
|
- |
| F.8.1.2.3("Rapid change of temperature
test") |
- |
65000 |
|
- |
| F 8.1.2.4(Impact test) |
- |
25000 |
|
- |
| F 8.1.2.6("Dielectric test
after stresses") |
- |
25000 |
|
- |
| C.1.2(Observation) |
- |
5000 |
|
- |
| C.2(Mechanical durability) |
- |
15000 |
|
- |
| C.3(Electrical durability) |
- |
25000 |
|
- |
| Annex C of IEC 60947-1:2007 (Sequence 5)(Degree of protection of enclosed control circuit devices) |
- |
35000 |
|
- |
| 8.3.4.4 a)(Condition of the switching element after the test) |
- |
25000 |
|
- |
| 8.3.4.4 b)(Condition of the switching element after the test) |
- |
25000 |
|
- |
| 8.3.4.1(General conditions for short-circuit tests) |
- |
115000 |
|
- |
| 8.3.4.2(Performance under conditional short-circuit current : Test procedure) |
- |
115000 |
|
- |
| 8.3.4.3(Test circuit and test quantities) |
- |
25000 |
|
- |
| 8.3.3.5.2(Test circuits and connections) |
- |
35000 |
|
- |
| 8.3.3.5(Making and breaking capacities) |
- |
115000 |
|
- |
| 8.3.3.2(Operating limits of contactor relays) |
- |
35000 |
|
- |
| 7.2.3(Dielectric properties) |
- |
25000 |
|
- |
| 8.3.3.4(Dielectric properties) |
- |
25000 |
|
- |
| 8.3.3.3(Temperature rise) |
- |
45000 |
|
- |
| 8.1.5(Special tests) |
- |
35000 |
|
- |
| 8.2.7(Conduit pull-out test, torque test and bending test with metallic conduits) |
- |
35000 |
|
- |
| 8.2.6 (Sequence 6)(Verification of limitation of rotation (of a rotary switch)) |
- |
45000 |
|
- |
| 8.2.1.1(Test of resistance to abnormal heat and fire) |
- |
35000 |
|
- |
| 8.2.5 (Sequence 5)(Verification of actuating force (or moment)) |
- |
35000 |
|
- |
| 8.2.4.5(Test for insertability of unprepared round copper conductors having the maximum cross-section) |
- |
35000 |
|
- |
| 8.2.1.1.1(Glow-wire test) |
- |
10000 |
|
- |
| 8.2.4.4(Pull-out test) |
- |
15000 |
|
- |
| 8.2.4.3(Testing for damage to and accidental loosening of conductors (flexion test)) |
- |
25000 |
|
- |
| 8.2.1.1.2(Flammability, hot wire ignition and arc ignition tests (on materials)) |
- |
35000 |
|
- |
| 8.2.4.2(Tests of mechanical strength of terminals) |
- |
25000 |
|
- |
| 8.2.4(Mechanical and electrical properties of terminals) |
- |
45000 |
|
- |
| 8.2.3(Enclosures for equipment) |
- |
35000 |
|
- |
| 8.3.3.5.6 b(Dielectric verification) |
- |
25000 |
|
- |
| 8.3.4(Performance under Conditional Short-Circuit Current) |
- |
115000 |
|
- |
| 8.3.3.5.3(Making and breaking capacities of switching elements under abnormal conditions) |
- |
115000 |
|
- |
| 8.3.3.5.4(Making and breaking capacities of switching elements under abnormal conditions) |
- |
115000 |
|
- |
|
08 May, 2028 |
- Included w.e.f 26.12.2025
Cl. No. 8.2.1.1.2, Cl. No. 7.3.2, Cl. No. 7.3.3, Cl. No. 8.4.2.4, Cl. No. 8.4.2.4, Cl. No. H.8.7 |
| 4456 |
JBS TESTING SOLUTIONS PVT LTD (27), JALANDHAR
| 9164606
| IS 7485 : Part 2 (2018) |
Countersunk flat head screws (common head style) with type H or Type Z Cross Recess - Product Grade A part 2 Steel Screws of Property Class 8.8, Stainless Steel Screws and Non - Ferrous Metal Screws ( Third Revision) |
- |
19400 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 3(Dimensions) |
- |
8000 |
|
For complete dimension and other qualitative tests |
| 4, table 2(Material) |
- |
5000 |
|
For chemical testing |
| 4, table 2(Thread) |
- |
7999.99 |
|
For complete dimension and other qualitative tests |
| 4, table 2(Mechanical property) |
- |
6400 |
|
For mechanical tests |
| 4, table 2(Tolerances) |
- |
8000 |
|
For complete dimension and other qualitative tests |
| 4, table 2(Cross recess) |
- |
8000 |
|
For complete dimension and other qualitative tests |
| 4, table 2(Finish - coating) |
- |
8000 |
|
For complete dimension and other qualitative tests |
| 4, table 2(Surface integrity) |
- |
8000 |
|
For complete dimension and other qualitative tests |
| 4, table 2(Acceptability) |
- |
8000 |
|
For complete dimension and other qualitative tests |
| 5(Designation) |
- |
8000 |
|
For complete dimension and other qualitative tests |
|
- |
- Included w.e.f 16.06.2025 |
| 4457 |
NAWaL Analytical Labs India Private Limited, Hosur
| 6126416
| IS 13334 : Part 2 (2014) |
Skimmed milk powder - Specification: Part 2 extra grade (First Revision) |
Extra grade |
9250 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Table 1 (i)(Moisture (IS 116231or 16072)) |
- |
600 |
|
18% GST extra |
| Table 1 (ii)(Milk protein in milk solids not fat (IS 72192)) |
- |
600 |
|
18% GST extra |
| Table 1 (iii)(Milk fat (IS 117213) or Annex B) |
- |
600 |
|
18% GST extra |
| Table 1 (iv)(Insolubility index (IS 12759)) |
- |
600 |
|
18% GST extra |
| Table 1 (v)(Total ash (on dry basis), Annex B of IS 14433) |
- |
600 |
|
18% GST extra |
| Table 1 (vi)(Titratable acidity (IS 11766)) |
- |
600 |
|
18% GST extra |
| Table 1 (vii)(Lactate content (IS 11202)) |
- |
1050 |
|
18% GST extra |
| Table 1 (viii)(Scorched particles (equivalent to Disc B) (IS 13500)) |
- |
600 |
|
18% GST extra |
| Table 1 (ix)(Bacterial count (IS 5402)) |
- |
500 |
|
18% GST extra |
| Table 1 (x)(Coliform count (IS 5401 - Part 1)) |
- |
500 |
|
18% GST extra |
| Table 1 (xi)(Escherichia coli (IS 5887 - Part 1)) |
- |
500 |
|
18% GST extra |
| Table 1 (xii)(Coagulase positive Staphylococcus aureus (IS 5887 - Part 2)) |
- |
500 |
|
18% GST extra |
| Table 1 (xiii)(Salmonella (IS 5887 - Part 3)) |
- |
500 |
|
18% GST extra |
| Table 1 (xiv)(a)(Spore Count: a)Aerobic (Bacillus cereus) Type m (IS 5887 - Part 6)) |
- |
500 |
|
18% GST extra |
| Table 1 (xiv)(b)(Spore Count: b) Anaerobic (Sulfite reducing Clostridia) Type m (ISO 15213 : 2003)) |
- |
500 |
|
18% GST extra |
| Table 1 (xv)(Listeria monocytogenes (IS 14988 - Part 2 : 2001)) |
- |
500 |
|
18% GST extra |
| Table 1 (xiv)(a)(Spore Count: a) Aerobic (Bacillus cereus) Type M (IS 5887 - Part 6)) |
- |
0 |
|
0 |
| Table 1 (xiv)(b)(Spore Count: b) Anaerobic (Sulfite reducing Clostridia) Type M (ISO 15213 : 2003)) |
- |
0 |
|
0 |
|
21 Mar, 2028 |
- - |
| 4458 |
NAWaL Analytical Labs India Private Limited, Hosur
| 6126416
| IS 13334 : Part 1 (2014) |
Skimmed milk powder - Specification: Part 1 standard grade (Second Revision) |
Standard Grade |
8300 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 5.6(Scorched particles) |
- |
500 |
|
18% GST extra |
| 5.6(Titratable acidity (lactic acid)) |
- |
500 |
|
18% GST extra |
| 5.6(Total ash (on dry basis)) |
- |
500 |
|
18% GST extra |
| 5.6(Insolubility index) |
- |
500 |
|
18% GST extra |
| 5.6(Milk fat) |
- |
1100 |
|
18% GST extra |
| 5.6(Milk protein in milk solids not fat) |
- |
500 |
|
18% GST extra |
| 5.6(Listeria monocytogenes) |
- |
500 |
|
18% GST extra |
| 5.6(Spore count, Anaerobic (Sulfite reducing Clostridia)) |
- |
500 |
|
18% GST extra |
| 5.6(Spore count, Aerobic (Bacillus cereus)) |
- |
500 |
|
18% GST extra |
| 5.6(Salmonella) |
- |
500 |
|
18% GST extra |
| 5.6(Coagulase positive Staphylococcus aureus) |
- |
500 |
|
18% GST extra |
| 5.6(Escherichia coli) |
- |
500 |
|
18% GST extra |
| 5.6(Coliform count ) |
- |
500 |
|
18% GST extra |
| 5.6(Bacterial count) |
- |
500 |
|
18% GST extra |
| 5.6(Moisture) |
- |
500 |
|
18% GST extra |
|
21 Mar, 2028 |
- - |
| 4459 |
Havells India Limited (Havells Research & Development Laboratory)
| 8187226
| IS/IEC 60947 : Part 4 : Sec 1 (2018) |
Low-Voltage switchgear and controlgear : Part 4-1 Contactors and motor starters electromechanical contactors and motor-Starters |
Contactors and Motor-Starters |
2235000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 8.1.2(Materials) |
- |
0 |
|
Only for internal testing |
| 8.1.2.1(General materials requirements) |
- |
0 |
|
Only for internal testing |
| 8.1.2.2(Glow wire testing) |
- |
15000 |
|
Only for internal testing |
| 8.1.3(Current-carrying parts and their connections) |
- |
0 |
|
Only for internal testing |
| 8.1.4(Clearances and creepage distances) |
- |
20000 |
|
Only for internal testing |
| 8.1.5.1(Insulation) |
- |
10000 |
|
Only for internal testing |
| 8.1.5.2(Direction of movement) |
- |
10000 |
|
Only for internal testing |
| 8.1.5.3(Mounting) |
- |
10000 |
|
Only for internal testing |
| 8.1.5.4(Protection) |
- |
0 |
|
Only for internal testing |
| 8.1.8(Terminals) |
- |
10000 |
|
Only for internal testing |
| 8.1.8.1(General) |
- |
10000 |
|
Only for internal testing |
| 8.1.8.2(Terminal identification and marking) |
- |
10000 |
|
Only for internal testing |
| 8.1.10(Provisions for protective earthing) |
- |
0 |
|
Only for internal testing |
| 8.1.11(Enclosures for equipment) |
- |
20000 |
|
Only for internal testing |
| 8.1.11.1(Design) |
- |
0 |
|
Only for internal testing |
| 8.1.11.2(Insulation) |
- |
10000 |
|
Only for internal testing |
| 8.1.12(Degrees of protection of enclosed equipment) |
- |
30000 |
|
Only for internal testing |
| 8.1.14(Limited energy source) |
- |
10000 |
|
Only for internal testing |
| 8.1.14.1(General) |
- |
0 |
|
Only for internal testing |
| 8.1.14.2(Limited energy source with galvanic separation) |
- |
0 |
|
Only for internal testing |
| 8.1.16(Fault and abnormal conditions) |
- |
10000 |
|
Only for internal testing |
| 8.1.17(Short-circuit and overload protection of ports) |
- |
10000 |
|
Only for internal testing |
| 8.2(Performance requirements) |
- |
0 |
|
Only for internal testing |
| 8.2.1(Operating conditions) |
- |
0 |
|
Only for internal testing |
| 8.2.1.1.1(General conditions) |
- |
0 |
|
Only for internal testing |
| 8.2.1.2(Limits of operation of contactors and power-operated starters) |
- |
10000 |
|
Only for internal testing |
| 8.2.1.3(Limits of operation of under-voltage relays and releases) |
- |
10000 |
|
Only for internal testing |
| 8.2.1.4(Limits of operation of shunt-coil operated releases (shunt trip)) |
- |
10000 |
|
Only for internal testing |
| 8.2.1.5(Limits of operation of current sensing relays and releases) |
- |
10000 |
|
Only for internal testing |
| 8.2.1.5.1(Limits of operation of time-delay overload relays when all poles are energized) |
- |
10000 |
|
Only for internal testing |
| 8.2.1.5.1.1(General tripping requirements of overload relays) |
- |
20000 |
|
Only for internal testing |
| 8.2.1.5.2(Limits of operation of three-pole time-delay overload relays energized on two poles) |
- |
20000 |
|
Only for internal testing |
| 8.2.1.5.3(Limits of operation of instantaneous magnetic overload relays) |
- |
10000 |
|
Only for internal testing |
| 8.2.1.5.4(Limits of operation of under-current relays and releases for automatic change over) |
- |
10000 |
|
Only for internal testing |
| 8.2.1.5.4.1(Limits of operation of under-current relays) |
- |
10000 |
|
Only for internal testing |
| 8.2.1.5.4.2(Limits of operation of automatic change over by under-current relays) |
- |
10000 |
|
Only for internal testing |
| 8.2.2(Temperature-rise) |
- |
30000 |
|
Only for internal testing |
| 8.2.2.3(Accessible parts) |
- |
10000 |
|
Only for internal testing |
| 8.2.2.4(Ambient air temperature) |
- |
10000 |
|
Only for internal testing |
| 8.2.2.5(Main circuit) |
- |
0 |
|
Only for internal testing |
| 8.2.2.6(Control circuits) |
- |
0 |
|
Only for internal testing |
| 8.2.2.7.1(Uninterrupted and eight-hour duty windings) |
- |
10000 |
|
Only for internal testing |
| 8.2.3(Dielectric properties) |
- |
20000 |
|
Only for internal testing |
| 8.2.3.2(Voltage limiting components between circuits) |
- |
0 |
|
Only for internal testing |
| 8.2.4.3.1(Mechanical durability) |
- |
20000 |
|
Only for internal testing |
| 8.2.4.3.2(Electrical durability) |
- |
20000 |
|
Only for internal testing |
| 8.2.4.4(Overload current withstand capability of contactors) |
- |
30000 |
|
Only for internal testing |
| 8.2.4.5(Coil power consumption) |
- |
30000 |
|
Only for internal testing |
| 8.2.4.6(Pole impedance) |
- |
30000 |
|
Only for internal testing |
| 8.2.4.7(Ability of a MPSD to make and break under short-circuit conditions) |
- |
100000 |
|
Only for internal testing |
| 8.2.5.1(Performance under short-circuit conditions) |
- |
200000 |
|
Only for internal testing, as per each rating |
| 8.2.5.3(Co-ordination test between AC-3e rated starter and associated SCPD) |
- |
200000 |
|
Only for internal testing, as per each rating |
| 8.2.5.4(Co-ordination between a MPSD and another short-circuit protective device) |
- |
200000 |
|
200000 |
| 9.1.5.2(Environment tests) |
- |
0 |
|
Only for internal testing |
| 9.2.4(Limited energy source test) |
- |
10000 |
|
Only for internal testing |
| 9.3.3.2(Operating limits) |
- |
20000 |
|
Only for internal testing |
| 9.3.3.2.1.2(Coil power consumption) |
- |
30000 |
|
Only for internal testing |
| 9.3.3.2.1.3(Pole impedance) |
- |
30000 |
|
Only for internal testing |
| 9.3.3.2.2(Relays and releases) |
- |
20000 |
|
Only for internal testing |
| 9.3.3.3.1(Ambient air temperature) |
- |
0 |
|
Only for internal testing |
| 9.3.3.3.2(Measurement of the temperature of parts) |
- |
30000 |
|
Only for internal testing |
| 9.3.3.3.3(Temperature-rise of a part) |
- |
30000 |
|
Only for internal testing |
| 9.3.3.3.4(Temperature-rise of the main circuit) |
- |
30000 |
|
Only for internal testing |
| 9.3.3.3.5(Temperature-rise of control circuits) |
- |
30000 |
|
Only for internal testing |
| 9.3.3.3.6(Temperature-rise of coils and electromagnets) |
- |
30000 |
|
Only for internal testing |
| 9.3.3.3.7(Temperature-rise of auxiliary circuits) |
- |
30000 |
|
Only for internal testing |
| 9.3.3.3.8(Temperature-rise of starting resistors for rheostatic rotor starters) |
- |
30000 |
|
Only for internal testing |
| 9.3.3.6(Operational performance capability) |
- |
80000 |
|
Only for internal testing |
| 9.3.4.2.2(prospective current) |
- |
200000 |
|
Only for internal testing, as per each rating |
| 9.3.4.2.3(Test at the rated conditional short-circuit current Iq) |
- |
200000 |
|
Only for internal testing, as per each rating |
| 9.3.5(Overload current withstand capability of contactors) |
- |
30000 |
|
Only for internal testing |
| 9.3.6.2(Operation and operating limits) |
- |
30000 |
|
Only for internal testing |
| 9.3.6.3(Dielectric tests) |
- |
20000 |
|
Only for internal testing |
| 9.3.6.4(Mechanical operation tests of a MPSD) |
- |
90000 |
|
Only for internal testing |
| 8.2.4 of IEC 60947-1:2007 (Sequence 5)(Verification of Mechanical properties of terminals) |
- |
30000 |
|
Only for internal testing |
| Annex C of IEC 60947-1:2007 (Sequence 5)(Verification of Degree of protection of enclosed contactors and starters) |
- |
30000 |
|
Only for internal testing |
|
07 Aug, 2028 |
- - |
| 4460 |
Havells India Limited (Havells Research & Development Laboratory)
| 8187226
| IS/IEC 60947 : Part 2 (2016) |
Low - Voltage switchgear and controlgear: Part 2 circuit - Breakers (First Revision) |
Circuit-Breakers |
3874000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 8.3.3.2(Tripping limits and characteristics) |
- |
100000 |
|
Only for internal testing |
| 8.3.3.3(Test of dielectric properties) |
- |
65000 |
|
Only for internal testing |
| 8.3.3.4(Mechanical operation and operational performance capability) |
- |
90000 |
|
Only for internal testing |
| 8.3.3.5(Overload performance) |
- |
150000 |
|
Only for internal testing |
| 8.3.3.6(Verification of dielectric withstand) |
- |
30000 |
|
Only for internal testing |
| 8.3.3.7(Verification of temperature-rise) |
- |
25000 |
|
Only for internal testing |
| 8.3.3.8(Verification of Overload releases) |
- |
4000 |
|
Only for internal testing |
| 8.3.3.9(Verification of undervoltage and shunt releases) |
- |
10000 |
|
Only for internal testing |
| 8.3.3.10(Verification of main contact position) |
- |
5000 |
|
Only for internal testing |
| 8.3.4.3(Verification of operational performance capability) |
- |
50000 |
|
Only for internal testing |
| 8.3.8.5(Verification of operational performance capability) |
- |
30000 |
|
Only for internal testing |
| 8.4.2(Mechanical operation tests) |
- |
15000 |
|
Only for internal testing |
| 8.4.3(Verification of the calibration of overcurrent releases) |
- |
10000 |
|
Only for internal testing |
| 8.4.4(Verification of the operation of undervoltage and shunt releases) |
- |
10000 |
|
Only for internal testing |
| 8.4.6(Dielectric tests) |
- |
60000 |
|
Only for internal testing |
| 8.4.7(Test for the verifiacation of clearances less than those corresponding to case A of Table 13 of IEC 60947-1:2007) |
- |
3000 |
|
Only for internal testing |
| 8.3.4.4(Verification of dielectric withstand) |
- |
28000 |
|
Only for internal testing |
| 8.3.5.4(Verification of dielectric withstand) |
- |
28000 |
|
Only for internal testing |
| 8.3.6.6(Verification of dielectric withstand) |
- |
28000 |
|
Only for internal testing |
| 8.3.8.6(Verification of dielectric withstand) |
- |
28000 |
|
Only for internal testing |
| 8.3.4.5(Verifiation of temperature-rise) |
- |
25000 |
|
Only for internal testing |
| 8.3.6.4(Verification of temperature-rise) |
- |
25000 |
|
Only for internal testing |
| 8.3.8.7(Verification of temperature-rise) |
- |
25000 |
|
Only for internal testing |
| 8.3.4.6(Verification of Overload releases) |
- |
5000 |
|
Only for internal testing |
| 8.3.5.2(Verification of Overload releases) |
- |
5000 |
|
Only for internal testing |
| 8.3.5.5(Verification of Overload releases) |
- |
5000 |
|
Only for internal testing |
| 8.3.6.2(Verification of Overload releases) |
- |
5000 |
|
Only for internal testing |
| 8.3.6.7(Verification of Overload releases) |
- |
5000 |
|
Only for internal testing |
| 8.3.8.2(Verification of Overload releases) |
- |
5000 |
|
Only for internal testing |
| 8.3.8.8(Verification of Overload releases) |
- |
5000 |
|
Only for internal testing |
| 8.3.4.1(General) |
- |
0 |
|
Only for internal testing |
| 8.3.4.2(Test of service short circuit breaking capacity) |
- |
10000 |
|
Only for internal testing |
| 8.3.5.1(General) |
- |
0 |
|
Only for internal testing |
| 8.3.5.3(Rated ultimate short-circuit breaking capacity) |
- |
200000 |
|
Only for internal testing as per each rating |
| 8.3.6.1(General) |
- |
0 |
|
Only for internal testing |
| 8.3.6.3(Rated short-time withstand current) |
- |
200000 |
|
Only for internal testing as per each rating |
| 8.3.6.5(Short-circuit breaking capacity at maximum short-time withstand current) |
- |
200000 |
|
Only for internal testing as per each rating |
| 8.3.7.1(General) |
- |
0 |
|
Only for internal testing |
| 8.3.8.1(General) |
- |
0 |
|
Only for internal testing |
| 8.3.8.3(Rated short-time withstand current) |
- |
200000 |
|
Only for internal testing as per each rating |
| 8.3.8.4(Rated service short-circuit breaking capacity*) |
- |
200000 |
|
Only for internal testing as per each rating |
| 8.3.4.1(General) |
- |
0 |
|
Only for internal testing |
| 8.3.4.2(rated short circuit breaking capacity (sequence II)) |
- |
200000 |
|
Only for internal testing as per each rating |
| 8.3.4.3(verification of operational performance capability (sequence II)) |
- |
50000 |
|
Only for internal testing |
| 8.3.4.4(verification of dielectric withstand (sequnce II)) |
- |
28000 |
|
Only for internal testing |
| 8.3.4.5(verification of temperature-rise (sequence II)) |
- |
25000 |
|
Only for internal testing |
| 8.3.4.6(verification of overload releases (sequence II)) |
- |
5000 |
|
Only for internal testing |
| 8.3.5.1(General) |
- |
0 |
|
Only for internal testing |
| 8.3.5.2(verification of overload releases (sequence III)) |
- |
5000 |
|
Only for internal testing |
| 8.3.5.3(rated short circuit breaking capacity (sequence III)) |
- |
200000 |
|
Only for internal testing as per each rating |
| 8.3.5.4(verification of dielectric withstand (sequnce III)) |
- |
28000 |
|
Only for internal testing |
| 8.3.5.5(verification of overload releases (sequence III)) |
- |
5000 |
|
Only for internal testing |
| 8.3.6.1(General) |
- |
0 |
|
Only for internal testing |
| 8.3.6.2(verification of overload releases (sequence IV)) |
- |
5000 |
|
Only for internal testing |
| 8.3.6.3(rated short circuit withstand current (sequence IV)) |
- |
200000 |
|
Only for internal testing as per each rating |
| 8.3.6.4(verification of temperature-rise (sequence IV)) |
- |
25000 |
|
Only for internal testing |
| 8.3.6.5(short circuit breaking capacity at maximum short time withstand current (sequence IV)) |
- |
200000 |
|
Only for internal testing as per each rating |
| 8.3.6.6(verification of dielectric withstand (sequence IV)) |
- |
28000 |
|
Only for internal testing |
| 8.3.6.7(verification of overload releases (sequence IV)) |
- |
5000 |
|
Only for internal testing |
| 8.3.8.1(General) |
- |
0 |
|
Only for internal testing |
| 8.3.8.2(verification of overload releases (sequence VI)) |
- |
5000 |
|
Only for internal testing |
| 8.3.8.3(rated short time withstand current (sequence VI)) |
- |
200000 |
|
Only for internal testing as per each rating |
| 8.3.8.4(rated service short circuit breaking capacity (sequence VI)) |
- |
200000 |
|
Only for internal testing as per each rating |
| 8.3.8.5(verification of operational performance capability (sequence VI)) |
- |
50000 |
|
Only for internal testing |
| 8.3.8.6(verification of dielectric withstand (sequence VI)) |
- |
28000 |
|
Only for internal testing |
| 8.3.8.7(verification of temperature-rise (sequence VI)) |
- |
25000 |
|
Only for internal testing |
| 8.3.8.8(verification of overload releases (sequence VI)) |
- |
5000 |
|
Only for internal testing |
| C.2(individual pole short circuit breaking capacity (Isu)) |
- |
200000 |
|
Only for internal testing as per each rating |
| C.3(verification of dielectric withstand) |
- |
25000 |
|
Only for internal testing |
| C.4(verification of overload releases) |
- |
5000 |
|
Only for internal testing |
| H.2(individual pole short circuit (IIT)) |
- |
200000 |
|
Only for internal testing as per each rating |
| H.3(verification of dielectric withstand) |
- |
28000 |
|
Only for internal testing |
| H.4(verification of overload releases) |
- |
5000 |
|
Only for internal testing |
|
07 Aug, 2028 |
- B.8.2 (Operating characteristics)
B.8.3 (Dielectric Properties)
B.8.4 (Operation of the test device at the limits of rated voltage)
B.8.5 (Limiting value of the non-operating current under over-current conditions)
B.8.6 (Resistance against unwanted tripping due to surge currents resulting from impulse voltage)
B.8.7 (Behavior in the case of an earth fault current comprising a d.c. component)
B.8.8 (Behavior in the case of failure of line voltage for CBRs classified under B.3.1.2.1)
B.8.9 (Behavior in the case of failure of line voltage for CBRs classified under B.3.1.2.2)
7.3 Annexure J Table J.1 (Electrostatic discharges)
7.3 Annexure J Table J.1 ("Radiated radio-frequency electromagnetic fields")
7.3 Annexure J Table J.1 ("Electrical fast transients/bursts")
7.3 Annexure J Table J.1 (Surges)
7.3 Annexure J Table J.1 ("Conducted disturbances induced by radio frequency fields")
7.3 Annexure J Table J.1 ("Power frequency magnetic fields")
7.3 Annexure J Table J.1 ("Voltage dips and interruptions")
7.3 Annexure J Table J.3 ("Conducted RF disturbances 150 kHz to 30 MHz")
7.3 Annexure J Table J.3 ("Radiated RF disturbances 30 MHz to 1 000 MHz")
8.3.9 (Critical d.c. load current test)
Cl.8.5 (Annex Q of IS/IEC 60947-1) (Special tests)
Annex G (Power loss)
Annex L (Circuit-breakers not fulfilling the requirements for overcurrent protection)
Annex M (Modular residual current devices (without integral current breaking device))
Annex N (Electromagnetic compatibility (EMC))
Annex O (Electromagnetic compatibility (EMC))
Annex P (DC circuit-breakers for use in photovoltaic (PV) applications)
Annex R (Circuit-breakers incorporating residual current protection with automatic re-closing functions)
8.3.7.1 (General)
8.3.7.2 ((stage 1) short circuit at the selectivity limit current (sequence V))
8.3.7.3 ((stage 1) verification of temperature-rise (sequence V))
8.3.7.4 ((stage 1) verification of dielectric withstand (sequence V))
8.3.7.5 ((stage 2) verification of overload releases (sequence V))
8.3.7.6 ((stage 2) short circuit at 1.1 time the take-over current (sequence V))
8.3.7.7 ((stage 2) short circuit at rated ultimate short circuit breaking capacity (sequence V))
8.3.7.8 ((stage 2) verification of dielectric withstand (sequence V))
8.3.7.9 ((stage 2) verification of overload releases (sequence V))
8.4.5 (Additional tests for CBRs)
8.3.7.4 (Verification of dielectric withstand)
8.3.7.8 (Verification of dielectric withstand)
8.3.7.3 (Verification of temperature-rise)
8.3.7.5 (Verification of Overload releases)
8.3.7.9 (Verification of Overload releases)
8.3.7.2 (Short-circuit at the selectivity limit current)
8.3.7.6 (Short-circuit at 1,1 times take-over current)
8.3.7.7 (Short-circuit at ultimate short-circuit breaking capacity) |
| 4461 |
Planet Electro Labs Private Limited, Wazirpur
| 8185226
| IS/IEC 60947 : Part 4 : Sec 2 (2020) |
Low-Voltage switchgear and Controlgear: Part 4-2 Contactors and Motorstarters semiconductor motor controllers starters and Soft starters |
- |
2500000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 6.2(Marking) |
- |
5000 |
|
- |
| 8.1(Constructional and performance requirements) |
- |
25000 |
|
- |
| 8.1.1(General) |
- |
115000 |
|
- |
| 8.1.2.1(General materials requirements) |
- |
25000 |
|
- |
| 8.1.2.2(Glow wire testing) |
- |
20000 |
|
- |
| 8.1.2.3(Test based on flammability category) |
- |
25000 |
|
- |
| 8.1.2.3(Test based on flammability category) |
- |
25000 |
|
- |
| 8.1.3(Current-carrying parts and their connections) |
- |
35000 |
|
- |
| 8.1.4(Clearances and creepage distances) |
- |
5000 |
|
- |
| 8.1.8, 8.1.8.1(General) |
- |
5000 |
|
- |
| 8.1.8.2(Terminal identification and marking) |
- |
5000 |
|
- |
| 8.1.10(Provisions for protective earthing) |
- |
35000 |
|
- |
| 8.1.11(Enclosures for equipment) |
- |
35000 |
|
- |
| 8.1.12(Degrees of protection of enclosed equipment) |
- |
65000 |
|
- |
| 8.1.13(Conduit pull-out, torque and bending with metallic conduits) |
- |
25000 |
|
- |
| 8.1.14.1(General) |
- |
10000 |
|
- |
| 8.1.14.2(Limited energy source with galvanic separation) |
- |
75000 |
|
- |
| 8.1.14.3(Limited energy source with current limiting impedance) |
- |
35000 |
|
- |
| 8.1.15(Stored charge energy circuit) |
- |
25000 |
|
- |
| 8.1.16(Fault and abnormal conditions) |
- |
35000 |
|
- |
| 8.1.17(Short-circuit and overload protection of ports) |
- |
115000 |
|
- |
| 9.5.2(Routine tests : Operation and operating limits) |
- |
75000 |
|
- |
| 9.5.3(Routine tests : Dielectric tests) |
- |
25000 |
|
- |
| 9.1.5.2(Environmental tests) |
- |
85000 |
|
- |
| 9.1.5.3(Coordination between the starter and the SCPD) |
- |
52000 |
|
- |
| 9.2.1(General) |
- |
5000 |
|
- |
| 9.2.2(Electrical performance of screwless-type clamping units) |
- |
35000 |
|
- |
| 9.2.3(Ageing test for screwless-type clamping units) |
- |
35000 |
|
- |
| 9.2.4(Limited energy source test) |
- |
35000 |
|
- |
| 9.2.5.1(General) |
- |
5000 |
|
- |
| 9.2.5.2(Breakdown of components test) |
- |
115000 |
|
- |
| 9.2.6(Wire flexing test) |
- |
25000 |
|
- |
| 9.3.3.3(Test sequence I : 1) Verification of temperature-rise) |
- |
35000 |
|
- |
| 9.3.3.4(Test sequence I : 2) Verification of dielectric properties) |
- |
25000 |
|
- |
| 9.3.3.6.2(Test sequence II : 1) Thermal stability test) |
- |
45000 |
|
- |
| 9.3.3.6.3(Test sequence II : 2) Overload capability test) |
- |
115000 |
|
- |
| 9.3.3.6.4("Test sequence II : 3) Blocking and commutating capability test, including verification of operation
and operating limits") |
- |
105000 |
|
- |
| 9.3.4(Test sequence III : Performance under short-circuit conditions) |
- |
120000 |
|
- |
| 9.2.5 of IEC 60947-1:2020, 9.2.2 and 9.2.3(Test sequence IV : 1) Verification of mechanical properties of terminals) |
- |
85000 |
|
- |
| Annex C of IEC 60947- 1:2020(Test sequence IV : 2) Verification of degrees of protection of enclosed equipment) |
- |
85000 |
|
- |
| 9.4.1(Test sequence V : General) |
- |
5000 |
|
- |
| 9.3.3.6.6(Test sequence VI : Tripping operation test) |
- |
65000 |
|
- |
|
08 May, 2028 |
- Included w.e.f 26.12.2025
Cl. No. 8.1.2.3, Cl. No. 8.2.4, Cl. No. 9.3.3.4, Cl. No. 9.3.3.6, Cl. No. 9.4.2, Cl. No. 9.4.3, Cl. No. 8.1.17, Cl. No. 8.2.5.1 and 9.3.4 |
| 4462 |
AJEO TESTING LABS PVT LTD, GHAZIABAD
| 8178606
| IS 1554 : Part 1 (1988) |
Specification for pvc insulated (Heavy Duty) electric cables: Part 1 for working voltages up to and including 1100 v (Third Revision) |
1100 V |
12000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 3.1(MATERIALS : CONDUCTOR) |
- |
500 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
| 4.1.1(INSULATION : General Purjose Insulaiion) |
- |
300 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
| 4.1.2(INSULATION : Heat Resisting Insulation) |
- |
300 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
| 5.1(MATERIALS : FILLER AND INNER SHEATH) |
- |
300 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
| 5.2(MATERIALS : FILLER AND INNER SHEATH) |
- |
300 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
| 6.1(MATERIALS : ARMGURING) |
- |
300 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
| 6.2(MATERIALS : ARMGURING) |
- |
300 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
| 7.1.1(OUTER SHEATH : For Cables with General Purpose InsuIafion) |
- |
300 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
| 7.1.2(OUTER SHEATH : For Cables with Heat Resisting InsuIalion) |
- |
300 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
| 8.1(CONSTRUCTION : CONDUCTOR) |
- |
300 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
| 8.2(CONSTRUCTION : CONDUCTOR) |
- |
300 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
| 9.1(INSULATION ) |
- |
400 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
| 9.2(INSULATION : Thickness of Insulation) |
- |
500 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
| 9.3(INSULATION :Tolerance on Thickness of Insulation) |
- |
500 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
| 9.4(INSULATION : Application of Insulation) |
- |
300 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
| 10.1(CORE IDENTIFICATION) |
- |
300 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
| 10.2(CORE IDENTIFICATION) |
- |
300 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
| 10.3(CORE IDENTIFICATION) |
- |
300 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
| 10.3.1(Arrangement of Marking) |
- |
300 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
| 11.1(LAYING UP OF CORES) |
- |
400 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
| 11.2(LAYING UP OF CORES) |
- |
400 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
| 12.1(INNER SHEATH) |
- |
300 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
| 12.2(INNER SHEATH) |
- |
300 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
| 12.3(INNER SHEATH :Thickness of Inner Sheath) |
- |
500 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
| 12.3.1(INNER SHEATH :Thickness of Inner Sheath) |
- |
400 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
| 13.1.1(ARMOURING : Application) |
- |
300 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
| 13.1.2(Armouring: Coverage ) |
- |
300 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
| 13.1.3(ARMOURING : Direction of lay ) |
- |
300 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
| 13.1.4(ARMOURING : Application) |
- |
300 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
| 13.2(ARMOURING : Type of Armour) |
- |
300 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
| 13.2.1(ARMOURING : Type of Armour) |
- |
300 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
| 13.3(Armouring : Dimensions -Wire Diameter) |
- |
400 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
| 13.3(Armouring : Dimensions -Formed wire ) |
- |
400 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
| 13.4(ARMOURING : Joints) |
- |
300 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
| 13.5.1(ARMOURING : Resistance) |
- |
300 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
| 13.5.2(ARMOURING : Resistance) |
- |
1000 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
| 13.6 a)(ARMOURING: Tensile Strength) |
- |
800 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
| 13.6 b)(ARMOURING: Elongation ) |
- |
800 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
| 13.6 c)(ARMOURING: Torsion Test (For round wire ) ) |
- |
800 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
| 13.6 d)(ARMOURING: Winding Test(For formed wire)) |
- |
800 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
| 13.6 e)(ARMOURING: Uniformity of zinc coating) |
- |
1000 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
| 13.6 f)(ARMOURING: Mass of zinc coating ) |
- |
1000 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
| 13.6 g)(ARMOURING: Resistivity) |
- |
1000 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
| 14.1(OUTER SHEATH) |
- |
200 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
| 14.2(OUTER SHEATH) |
- |
200 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
| 14.3(OUTER SHEATH : Colour ) |
- |
200 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
| 14.4.1(Thickness of Outer Sheath : Unarmowed Cables) |
- |
300 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
| 14.4.2(Thickness of Outer Sheath : Armoured Cables) |
- |
200 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
| 15.1 a) 1)(Tests on conductor : Annealing test ( for copper )) |
- |
500 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
| 15.1 a) 2)(Tensile test (for aluminium) - Before stranding ) |
- |
500 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
| 15.1 a) 2)(Tensile test (for aluminium) - After stranding ) |
- |
500 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
| 15.1 a) 3)(Tests on conductor : Wrapping test ( for aluminium )) |
- |
300 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
| 15.1 a) 4)(Tests on conductor : Conductor resistance test) |
- |
800 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
| 15.1 a) 4)(Resistance test - Neutral conductor ) |
- |
800 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
| 15.1 d)1)(Phyaical tests for insulation : Tensile Test) |
- |
500 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
| 15.1 d)1)(Phyaical tests for insulation : Elongation ) |
- |
500 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
| 15.1 d)1)(Physical tests for sheath : Tensile stregth ) |
- |
500 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
| 15.1 d)1)(Physical tests for sheath : Elongation ) |
- |
500 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
| 15.1 d)2)(Phyaical tests for insulation- Ageing in air Oven : Tensile Test) |
- |
1500 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
| 15.1 d)2)(Phyaical tests for insulation - Ageing in air oven : Elongation ) |
- |
1500 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
| 15.1 d)2)(Phyaical tests for insulation - Ageing in air Oven : Tensile Variation ) |
- |
1500 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
| 15.1 d)2)(Phyaical tests for insulation- Ageing in air oven : Elongation Variation ) |
- |
1500 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
| 15.1 d)2)(Physical tests for outer sheath- Ageing in air oven : Tensile stregth ) |
- |
1500 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
| 15.1 d)2)(Physical tests for outer sheath -Ageing in air oven : Elongation ) |
- |
1500 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
| 15.1 d)2)(Physical tests for outer sheath- Ageing in air oven : Tensile stregth Variation ) |
- |
1500 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
| 15.1 d)2)(Physical tests for outer sheath -Ageing in air oven : Elongation Variation ) |
- |
1500 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
| 15.1 d)3)(Phyaical tests for insulation : Shrinkage ) |
- |
500 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
| 15.1 d)3)(Phyaical tests for insulation : Shrinkage - Crack observed ) |
- |
500 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
| 15.1 d)3)(Phyaical tests for Sheath : Shrinkage ) |
- |
500 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
| 15.1 d)3)(Phyaical tests for Sheath : Shrinkage - Crack observed ) |
- |
500 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
| 15.1 d)4)(Hot deformation : Insulation ) |
- |
500 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
| 15.1 d)4)(Hot deformation : Sheath ) |
- |
500 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
| 15.1 d)5)( Loss of mass in air oven- Insulation ) |
- |
2000 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
| 15.1 d)5)( Loss of mass in air oven- sheath ) |
- |
2000 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
| 15.1 d)6)(Heat shock test- Insulation ) |
- |
500 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
| 15.1 d)6)(Heat shock test- sheath ) |
- |
500 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
| 15.1 d)7)(Thermal stability- insulation ) |
- |
600 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
| 15.1 d)7)(Thermal stability- Sheath ) |
- |
600 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
| 15.1 e)(Insulation resistance test : Volume Resistivity ) |
- |
1000 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
| 15.1 e)(Insulation resistance test : IR Constant ) |
- |
1000 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
| 15.1 f)(High voltage test ( water immersion test )) |
- |
1500 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
| 15.1 g)(High voltage test at room temperature) |
- |
1500 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
| 15.1 g)(High voltage test at room temperature) |
- |
1500 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
| 15.4 a)(Cold bend test- Insulation ( Optional test)) |
- |
800 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
| 15.4 a)(Cold bend test- Sheath ( Optional test)) |
- |
800 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
| 15.4 b)(Cold impact test- Insulation ( Optional test)) |
- |
800 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
| 15.4 b)(Cold impact test- Sheath ( Optional test)) |
- |
800 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
| 15.4 c)(Armour resistance test ( for other than mining cables ).- Optional test ) |
- |
500 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
| 16.1(DETAILS OF TESTS : General) |
- |
200 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
| 16.2(DETAILS OF TESTS : High Voltage Test at Room Temperature) |
- |
1500 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
| 16.3.1(High Voltage Test ( Water Immersion Test ) : a.c. Test) |
- |
1500 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
| 16.3.2(High Voltage Test ( Water Immersion Test ) : d.c. Test) |
- |
1500 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
| 16.4(Flammability Test) |
- |
800 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
| 16.5(Oxygen Index Test) |
- |
2500 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
| 16.6(Flame Retardance Test on Single Cables) |
- |
2500 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
| 16.7(Flame Retardance Test on Bunched Cables) |
- |
3000 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
| 16.9(Test for Halogen Acid Gas Evolution) |
- |
2000 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
| 16.1(Temperature Index) |
- |
2000 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
| 17.1(IDENTIFICATION : Manufacturer’s Identification) |
- |
300 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
| 17.2(IDENTIFICATION : Cable Identification) |
- |
300 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
| 17.2.1(IDENTIFICATION : Cable Identification) |
- |
300 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
| 17.3(IDENTIFICATION : Cable Code) |
- |
300 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
| 15.1.e(Insulation resistance Test- Insulation resistance At Maximum rated temperature temperature) |
- |
1000 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
| 15.1.e(Insulation resistance Test- Insulation resistance constant At Room temperature) |
- |
1000 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
| 15.1.e(Insulation resistance Test- Volume Resistivity At Maximum rated temperature temperature) |
- |
1000 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
| 15.1.e(Insulation resistance Test- Volume Resistivity At Room temperature) |
- |
1000 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
| 16.4(Flammability Test- Un affected portion) |
- |
1000 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
| 16.4(Flammability Test- Period of Burning) |
- |
800 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
| 9.3(Minimum Thickness of Reduce core insulation) |
- |
500 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
| 9.2(Thickness of Reduce core insulation) |
- |
500 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
| 3.1 Table 2
IS 8130(Number of wires in the conductor) |
- |
500 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
| Cl No. 16.10(Smoke density test) |
- |
500 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
| Cl No. 16.8(Test for specific optical density of smoke) |
- |
500 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
| Table 4(Copper purity test) |
- |
500 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
| Cl.8(Conductor, Number of wires.) |
- |
500 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
| Cl.8(Conductor, Number of wires.) |
- |
200 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
| Cl.8(Flexibility class) |
- |
200 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
| [(Cl.15), (d), 2](After ageing, Elongation of Sheath [Percentage]) |
- |
1500 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
| Cl No. 16.10(Smoke density test) |
- |
3500 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
| Cl No. 16.8(Test for specific optical density of smoke) |
- |
3500 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
| Table 4(Copper purity test) |
- |
3500 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
| Cl.8(Conductor, Number of wires.) |
- |
500 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
| Cl.8(Conductor, Number of wires.) |
- |
500 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
| Cl.8(Flexibility class) |
- |
500 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
| [(Cl.15), (d), 2](After ageing, Elongation of Sheath [Percentage]) |
- |
1500 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
|
- |
- Included w.e.f.04.07.2025 |
| 4463 |
JBS TESTING SOLUTIONS PVT LTD (27), JALANDHAR
| 9164606
| IS 7485 : Part 1 (2018) |
Countersunk Flat Head Screws (Common head Style) With Type H or Type Z Cross Recess - Product Grade A Part 1 Steel Screws of Property Class 4.8 ( Third Revision) |
- |
19400 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 3(Dimensions) |
- |
8000 |
|
For complete dimension and other qualitative tests |
| 4, table 2(Material) |
- |
5000 |
|
For chemical testing |
| 4, table 2(General requirements) |
- |
8000 |
|
For complete dimension and other qualitative tests |
| 4, table 2(Thread) |
- |
8000 |
|
For complete dimension and other qualitative tests |
| 4, table 2(Mechanical property) |
- |
6400 |
|
For mechanical tests |
| 4, table 2(Tolerances) |
- |
8000 |
|
For complete dimension and other qualitative tests |
| 4, table 2(Cross recess) |
- |
8000 |
|
For complete dimension and other qualitative tests |
| 4, table 2(Finish - coating) |
- |
8000.01 |
|
For complete dimension and other qualitative tests |
| 4, table 2(Surface integrity) |
- |
8000.03 |
|
For complete dimension and other qualitative tests |
| 4, table 2(Acceptability) |
- |
8000 |
|
For complete dimension and other qualitative tests |
| 5(Designation) |
- |
8000 |
|
For complete dimension and other qualitative tests |
|
- |
- Included w.e.f 16.06.2025 |
| 4464 |
JBS TESTING SOLUTIONS PVT LTD (27), JALANDHAR
| 9164606
| IS 13983 (1994) |
Stainless Steel Sinks For Domestic Purposes |
- |
19500 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 9(Marking) |
- |
1000 |
|
For other qualitative test |
| 4(Type) |
- |
1000 |
|
For other qualitative test |
| Cl. 5 , As per IS 5522-2014, Cl. 7.2 , Table 1 & 2 Grade Desig X-04-Cr-19-Ni-19 (Numeric Symbol 304)(Carbon Content) |
- |
5000 |
|
For chemical test |
| Cl. 5 , As per IS 5522-2014, Cl. 7.2 , Table 1 & 2 Grade Desig X-04-Cr-19-Ni-19 (Numeric Symbol 304)(Silicon Content) |
- |
5000 |
|
For chemical test |
| Cl. 5 , As per IS 5522-2014, Cl. 7.2 , Table 1 & 2 Grade Desig X-04-Cr-19-Ni-19 (Numeric Symbol 304)(Manganese Content) |
- |
5000 |
|
For chemical test |
| Cl. 5 , As per IS 5522-2014, Cl. 7.2 , Table 1 & 2 Grade Desig X-04-Cr-19-Ni-19 (Numeric Symbol 304)(Nickel Content) |
- |
5000 |
|
For chemical test |
| Cl. 5 , As per IS 5522-2014, Cl. 7.2 , Table 1 & 2 Grade Desig X-04-Cr-19-Ni-19 (Numeric Symbol 304)(Chromium Content) |
- |
5000 |
|
For chemical test |
| Cl. 5 , As per IS 5522-2014, Cl. 7.2 , Table 1 & 2 Grade Desig X-04-Cr-19-Ni-19 (Numeric Symbol 304)(Sulphur Content) |
- |
5000 |
|
For chemical test |
| Cl. 5 , As per IS 5522-2014, Cl. 7.2 , Table 1 & 2 Grade Desig X-04-Cr-19-Ni-19 (Numeric Symbol 304)(Phouphorous Content) |
- |
5000 |
|
For chemical test |
| Cl. 5 , As per IS 5522-2014, Cl. 7.2 , Table 1 & 2 Grade Desig X-04-Cr-19-Ni-19 (Numeric Symbol 304)(Nitrogen Content) |
- |
5000 |
|
For chemical test |
| Cl. 5 , As per IS 5522-2014, Cl. 7.2 , Table 1 & 2 Grade Desig X-07-Cr-18-Ni-9 (Numeric Symbol 302)(Carbon Content) |
- |
5000 |
|
For chemical test |
| Cl. 5 , As per IS 5522-2014, Cl. 7.2 , Table 1 & 2 Grade Desig X-07-Cr-18-Ni-9 (Numeric Symbol 302)(Silicon Content) |
- |
5000 |
|
For chemical test |
| Cl. 5 , As per IS 5522-2014, Cl. 7.2 , Table 1 & 2 Grade Desig X-07-Cr-18-Ni-9 (Numeric Symbol 302)(Manganese Content) |
- |
5000 |
|
For chemical test |
| Cl. 5 , As per IS 5522-2014, Cl. 7.2 , Table 1 & 2 Grade Desig X-07-Cr-18-Ni-9 (Numeric Symbol 302)(Nickel Content) |
- |
5000 |
|
For chemical test |
| Cl. 5 , As per IS 5522-2014, Cl. 7.2 , Table 1 & 2 Grade Desig X-07-Cr-18-Ni-9 (Numeric Symbol 302)(Chromium Content) |
- |
5000 |
|
For chemical test |
| Cl. 5 , As per IS 5522-2014, Cl. 7.2 , Table 1 & 2 Grade Desig X-07-Cr-18-Ni-9 (Numeric Symbol 302)(Sulphur Content) |
- |
5000 |
|
For chemical test |
| Cl. 5 , As per IS 5522-2014, Cl. 7.2 , Table 1 & 2 Grade Desig X-07-Cr-18-Ni-9 (Numeric Symbol 302)(Phouphorous Content) |
- |
5000 |
|
For chemical test |
| Cl. 5 , As per IS 5522-2014, Cl. 7.2 , Table 1 & 2 Grade Desig X-07-Cr-18-Ni-9 (Numeric Symbol 302)(Nitrogen Content) |
- |
5000 |
|
For chemical test |
| 6(Thickness of sheet/strip) |
- |
5000 |
|
For chemical test |
| 6(Depth of bowl) |
- |
13500 |
|
For dimensional and tolerance tests |
| 6(Internal dimensions of the bowl) |
- |
13500 |
|
For dimensional and tolerance tests |
| 6(Bowl locating limits) |
- |
13499.98 |
|
For dimensional and tolerance tests |
| 6(Co-ordinating sizes) |
- |
13500 |
|
For dimensional and tolerance tests |
| 7.1(Consruction and workmanship) |
- |
1000 |
|
For other qualitative test |
| 7.1.1(Consruction and workmanship) |
- |
1000 |
|
For other qualitative test |
| 7.2(Consruction and workmanship) |
- |
1000 |
|
For other qualitative test |
| 7.2.1(Consruction and workmanship) |
- |
1000 |
|
For other qualitative test |
| 7.3(Drainers) |
- |
1000 |
|
For other qualitative test |
| 7.4(Waste outlet) |
- |
1000 |
|
For other qualitative test |
| 7.5(Tap holes) |
- |
1000 |
|
For other qualitative test |
| 7.6(Overflows) |
- |
1000 |
|
For other qualitative test |
| 8(Finish) |
- |
1000 |
|
For other qualitative test |
| 5(MATERIALS) |
- |
1000 |
|
For other qualitative test |
| 6.1.1(Thickness of Sheet/Strip) |
- |
13500 |
|
For dimensional and tolerance tests |
| 6.1.2(Thickness of Sheet/Strip) |
- |
13500 |
|
For dimensional and tolerance tests |
| 6.2(Depth of Bowls) |
- |
13500 |
|
For dimensional and tolerance tests |
| 6.3(Internal Dimensions of Bowls) |
- |
13500 |
|
For dimensional and tolerance tests |
| 6.4.1(Bowl Locating Limits) |
- |
13500 |
|
For dimensional and tolerance tests |
| 6.5(Coordinating Sizes) |
- |
13500 |
|
For dimensional and tolerance tests |
| 7.1(CONSTRUCTION AND WORKMANSHIP) |
- |
1000 |
|
- |
| 7.1.1(CONSTRUCTION AND WORKMANSHIP) |
- |
1000 |
|
- |
| 7.2.1(CONSTRUCTION AND WORKMANSHIP) |
- |
1000 |
|
- |
| 7.3(CONSTRUCTION AND WORKMANSHIP) |
- |
1000 |
|
- |
| 7.4(Waste Outlet) |
- |
1000 |
|
- |
| 7.5(Tap Holes) |
- |
1000.01 |
|
- |
| 7.6(OVERFLOW) |
- |
13500.02 |
|
- |
| Clause no. 4(types) |
- |
1000 |
|
- |
| Caluse no. 5("Material -Austenitic stainless steel of
Grade Designation") |
- |
13500.01 |
|
- |
| Clause no. 6.1(Thickness of sheet) |
- |
13500.03 |
|
- |
| Clause no. 6.2(Depth of Bowls) |
- |
13500 |
|
- |
| Clause no. 6.3(Internal dimensions of bowls) |
- |
13500 |
|
- |
| Clause no. 6.4(Bowl Locating Limits) |
- |
13500 |
|
- |
| Clause no. 6.5, Table No. 1(Dimension of the sink) |
- |
13500 |
|
- |
| Clause no. 7(Construction and workmanship) |
- |
1000.02 |
|
- |
| Clause no. 8(Finish) |
- |
1000 |
|
- |
| Clause no. 9(Mark) |
- |
1000 |
|
- |
|
- |
- Included w.e.f 16.06.2025 |
| 4465 |
Planet Electro Labs Private Limited, Wazirpur
| 8185226
| IS/IEC 60947 : Part 4 : Sec 1 (2018) |
Low-Voltage switchgear and controlgear : Part 4-1 Contactors and motor starters electromechanical contactors and motor-Starters |
- |
3000000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 8.1.2(Materials) |
- |
5000 |
|
- |
| 8.1.2.1(General materials requirements) |
- |
4000 |
|
- |
| 8.1.2.2(Glow wire testing) |
- |
5000 |
|
- |
| 8.1.2.3(Test based on flammability category) |
- |
10000 |
|
- |
| 8.1.3(Current-carrying parts and their connections) |
- |
15000 |
|
- |
| 8.1.4(Clearances and creepage distances) |
- |
5000 |
|
- |
| 8.1.5.1(Insulation) |
- |
10000 |
|
- |
| 8.1.5.2(Direction of movement) |
- |
15000 |
|
- |
| 8.1.5.3(Mounting) |
- |
15000 |
|
- |
| 8.1.5.4(Protection) |
- |
20000 |
|
- |
| 8.1.8(Terminals) |
- |
25000 |
|
- |
| 8.1.8.1(General) |
- |
5000 |
|
- |
| 8.1.8.2(Terminal identification and marking) |
- |
25000 |
|
- |
| 8.1.9(Additional requirements for equipment provided with a neutral pole) |
- |
25000 |
|
- |
| 8.1.10(Provisions for protective earthing) |
- |
35000 |
|
- |
| 8.1.11(Enclosures for equipment) |
- |
30000 |
|
- |
| 8.1.11.1(Design) |
- |
10000 |
|
- |
| 8.1.11.2(Insulation) |
- |
15000 |
|
- |
| 8.1.12(Degrees of protection of enclosed equipment) |
- |
35000 |
|
- |
| 8.1.13(Conduit pull-out, torque and bending with metallic conduits) |
- |
35000 |
|
- |
| 8.1.14(Limited energy source) |
- |
25000 |
|
- |
| 8.1.14.1(General) |
- |
10000 |
|
- |
| 8.1.14.2(Limited energy source with galvanic separation) |
- |
15000 |
|
- |
| 8.1.14.3(Limited energy source with current limiting impedance) |
- |
25000 |
|
- |
| 8.1.15(Stored charge energy circuit) |
- |
115000 |
|
- |
| 8.1.16(Fault and abnormal conditions) |
- |
25000 |
|
- |
| 8.1.17(Short-circuit and overload protection of ports) |
- |
140000 |
|
- |
| 8.2(Performance requirements) |
- |
180000 |
|
- |
| 8.2.1(Operating conditions) |
- |
20000 |
|
- |
| 8.2.1.1.1(General conditions) |
- |
15000 |
|
- |
| 8.2.1.2(Limits of operation of contactors and power-operated starters) |
- |
20000 |
|
- |
| 8.2.1.3(Limits of operation of under-voltage relays and releases) |
- |
25000 |
|
- |
| 8.2.1.4(Limits of operation of shunt-coil operated releases (shunt trip)) |
- |
35000 |
|
- |
| 8.2.1.5(Limits of operation of current sensing relays and releases) |
- |
35000 |
|
- |
| 8.2.1.5.1(Limits of operation of time-delay overload relays when all poles are energized) |
- |
35000 |
|
- |
| 8.2.1.5.1.1(General tripping requirements of overload relays) |
- |
115000 |
|
- |
| 8.2.1.5.1.2(Thermal memory test verification) |
- |
65000 |
|
- |
| 8.2.1.5.2(Limits of operation of three-pole time-delay overload relays energized on two poles) |
- |
115000 |
|
- |
| 8.2.1.5.3(Limits of operation of instantaneous magnetic overload relays) |
- |
95000 |
|
- |
| 8.2.1.5.4(Limits of operation of under-current relays and releases for automatic change over) |
- |
65000 |
|
- |
| 8.2.1.5.4.1(Limits of operation of under-current relays) |
- |
40000 |
|
- |
| 8.2.1.5.4.2(Limits of operation of automatic change over by under-current relays) |
- |
35000 |
|
- |
| 8.2.2(Temperature-rise) |
- |
95000 |
|
- |
| 8.2.2.3(Accessible parts) |
- |
20000 |
|
- |
| 8.2.2.4(Ambient air temperature) |
- |
25000 |
|
- |
| 8.2.2.5(Main circuit) |
- |
20000 |
|
- |
| 8.2.2.6(Control circuits) |
- |
20000 |
|
- |
| 8.2.2.7.1(Uninterrupted and eight-hour duty windings) |
- |
35000 |
|
- |
| 8.2.3(Dielectric properties) |
- |
25000 |
|
- |
| 8.2.3.2(Voltage limiting components between circuits) |
- |
35000 |
|
- |
| 8.2.4.3.1(Mechanical durability) |
- |
35000 |
|
- |
| 8.2.4.3.2(Electrical durability) |
- |
35000 |
|
- |
| 8.2.4.4(Overload current withstand capability of contactors) |
- |
45000 |
|
- |
| 8.2.4.5(Coil power consumption) |
- |
45000 |
|
- |
| 8.2.4.6(Pole impedance) |
- |
35000 |
|
- |
| 8.2.4.7(Ability of a MPSD to make and break under short-circuit conditions) |
- |
0 |
|
- |
| 8.2.5.1(Performance under short-circuit conditions) |
- |
115000 |
|
- |
| 8.2.5.3(Co-ordination test between AC-3e rated starter and associated SCPD) |
- |
35000 |
|
- |
| 8.2.5.4(Co-ordination between a MPSD and another short-circuit protective device) |
- |
0 |
|
- |
| 9.1.5.2(Environment tests) |
- |
65000 |
|
- |
| 9.2.2(Electrical performance of screwless-type clamping units) |
- |
35000 |
|
- |
| 9.2.3(Ageing test for screwless-type clamping unit) |
- |
30000 |
|
- |
| 9.2.4(Limited energy source test) |
- |
30000 |
|
- |
| 9.2.5(Breakdown of components) |
- |
25000 |
|
- |
| 9.2.5.2(Breakdown of components test) |
- |
45000 |
|
- |
| 9.3.3.2(Operating limits) |
- |
35000 |
|
- |
| 9.3.3.2.1.2(Coil power consumption) |
- |
25000 |
|
- |
| 9.3.3.2.1.3(Pole impedance) |
- |
25000 |
|
- |
| 9.3.3.2.2(Relays and releases) |
- |
35000 |
|
- |
| 9.3.3.3.1(Ambient air temperature) |
- |
35000 |
|
- |
| 9.3.3.3.2(Measurement of the temperature of parts) |
- |
65000 |
|
- |
| 9.3.3.3.3(Temperature-rise of a part) |
- |
45000 |
|
- |
| 9.3.3.3.4(Temperature-rise of the main circuit) |
- |
45000 |
|
- |
| 9.3.3.3.5(Temperature-rise of control circuits) |
- |
45000 |
|
- |
| 9.3.3.3.6(Temperature-rise of coils and electromagnets) |
- |
45000 |
|
- |
| 9.3.3.3.7(Temperature-rise of auxiliary circuits) |
- |
45000 |
|
- |
| 9.3.3.3.8(Temperature-rise of starting resistors for rheostatic rotor starters) |
- |
45000 |
|
- |
| 9.3.3.6(Operational performance capability) |
- |
120000 |
|
- |
| 9.3.4.2.2(prospective current) |
- |
35000 |
|
- |
| 9.3.4.2.3(Test at the rated conditional short-circuit current Iq) |
- |
1000000 |
|
- |
| 9.3.5(Overload current withstand capability of contactors) |
- |
40000 |
|
- |
| 9.3.6.2(Operation and operating limits) |
- |
25000 |
|
- |
| 9.3.6.3(Dielectric tests) |
- |
25000 |
|
- |
| 9.3.6.4(Mechanical operation tests of a MPSD) |
- |
35000 |
|
- |
| F.7.2(Tests on products in a new condition) |
- |
30000 |
|
- |
| F.7.3(Test after conventional operational performance) |
- |
35000 |
|
- |
| H.3(Limits of operation of control functions) |
- |
35000 |
|
- |
| H.4(Test of the control functions) |
- |
25000 |
|
- |
| M.9.4(Thermal cycling test) |
- |
65000 |
|
- |
| M.9.5(Climatic test) |
- |
55000 |
|
- |
| M.9.7(Critical load current test) |
- |
135000 |
|
- |
| 8.2.4 of IEC 60947-1:2007 (Sequence 5)(Verification of Mechanical properties of terminals) |
- |
35000 |
|
- |
| Annex C of IEC 60947-1:2007 (Sequence 5)(Verification of Degree of protection of enclosed contactors and starters) |
- |
35000 |
|
- |
| M.9.11(Clearance and creepage distances) |
- |
5000 |
|
- |
| N.3.2(Touch current measurement) |
- |
8000 |
|
- |
| P.2.3(Verification of operational performance capability) |
- |
115000 |
|
- |
| P.2.4.2(Test voltage) |
- |
30000 |
|
- |
| P.2.4.3(Application of the test voltage) |
- |
120000 |
|
- |
| Q.5.3(Selectivity determined by test) |
- |
25000 |
|
- |
|
08 May, 2028 |
- Included w.e.f 26.12.2025
Cl. No. 8.2.4, Cl. No. 8.2.5.3, Cl. No. 9.3.3.5.5, Cl. No. 9.4, Cl. No. M.8.3/Cl.8.3, Cl. No. P.4, Cl. No. 8.2.5.1, Cl. No. 9.3.4 |
| 4466 |
Bharat Test House Pvt. Ltd. 1668 Sonipat
| 9168306
| IS 13422 (2024) |
Single-use Sterile Rubber Surgical Gloves � Specification (First Revision) |
Single-use Sterile Rubber Surgical Gloves |
10000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl-5(Materials) |
- |
2000 |
|
Excluding: Cl.5.4_Materials & Cl.7.4_Sterility |
| Cl-6(Sampling and selection of test pieces) |
- |
500 |
|
- |
| Cl-7.1(Dimensions) |
- |
1000 |
|
- |
| Cl-7.2(Watertightness) |
- |
2000 |
|
- |
| Cl-7.3(Tensile properties) |
- |
2000 |
|
- |
| Cl-7.3.1(General) |
- |
2000 |
|
- |
| Cl-7.3.2(Force at break and elongation at break before accelerated ageing) |
- |
2000 |
|
- |
| Cl-7.3.3(Force at break and elongation at break after accelerated ageing) |
- |
2000 |
|
- |
| Cl-7.3.4(Force required to produce 300 % elongation) |
- |
2000 |
|
- |
| Cl-7.4(Sterility) |
- |
0 |
|
Excluding: Cl.7.4_Sterility |
| Cl-9(Marking.) |
- |
500 |
|
- |
| Cl-5(Materials) |
- |
0 |
|
- |
| Cl-6(Sampling and selection of test pieces) |
- |
0 |
|
- |
| Cl-7.1(Dimensions) |
- |
0 |
|
- |
| Cl-7.2(Watertightness) |
- |
0 |
|
- |
| Cl-7.3(Tensile properties) |
- |
0 |
|
- |
| Cl-7.3.1(General) |
- |
0 |
|
- |
| Cl-7.3.2(Force at break and elongation at break before accelerated ageing) |
- |
0 |
|
- |
| Cl-7.3.3(Force at break and elongation at break after accelerated ageing) |
- |
0 |
|
- |
| Cl-7.3.4(Force required to produce 300 % elongation) |
- |
0 |
|
- |
| Cl-7.4(Sterility) |
- |
0 |
|
- |
| Cl-9(Marking.) |
- |
0 |
|
- |
| Cl-5(Materials) |
- |
0 |
|
- |
| Cl-6(Sampling and selection of test pieces) |
- |
0 |
|
- |
| Cl-7.1(Dimensions) |
- |
0 |
|
- |
| Cl-7.2(Watertightness) |
- |
0 |
|
- |
| Cl-7.3(Tensile properties) |
- |
0 |
|
- |
| Cl-7.3.1(General) |
- |
0 |
|
- |
| Cl-7.3.2(Force at break and elongation at break before accelerated ageing) |
- |
0 |
|
- |
| Cl-7.3.3(Force at break and elongation at break after accelerated ageing) |
- |
0 |
|
- |
| Cl-7.3.4(Force required to produce 300 % elongation) |
- |
0 |
|
- |
| Cl-7.4(Sterility) |
- |
0 |
|
- |
| Cl-9(Marking.) |
- |
0 |
|
- |
| Cl-5(Materials) |
- |
0 |
|
- |
| Cl-6(Sampling and selection of test pieces) |
- |
0 |
|
- |
| Cl-7.1(Dimensions) |
- |
0 |
|
- |
| Cl-7.2(Watertightness) |
- |
0 |
|
- |
| Cl-7.3(Tensile properties) |
- |
0 |
|
- |
| Cl-7.3.1(General) |
- |
0 |
|
- |
| Cl-7.3.2(Force at break and elongation at break before accelerated ageing) |
- |
0 |
|
- |
| Cl-7.3.3(Force at break and elongation at break after accelerated ageing) |
- |
0 |
|
- |
| Cl-7.3.4(Force required to produce 300 % elongation) |
- |
0 |
|
- |
| Cl-7.4(Sterility) |
- |
0 |
|
- |
| Cl-9(Marking.) |
- |
0 |
|
- |
|
- |
- Included w.e.f.18.08.2025
Exclusion
Cl-7.4 (Sterility) |
| 4467 |
BCH Electric Limited, Faridabad
| 8186026
| IS/IEC 60947 : PART 3 (2020) |
Low-Voltage Switchgear and Controlgear: Part 3 Switches Disconnectors Switch-Disconnectors and Fuse-Combination Units |
I MCB SOLATOR, MCCB ISOLATOR SWITCH, SWITCH DISCONNECTORS, FUSE COMBINATION |
820000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 3.1(General) |
- |
2000 |
|
Only for internal testing |
| 4(Classification) |
- |
2000 |
|
Only for internal testing |
| 5.3.2(Rated voltages) |
- |
2000 |
|
Only for internal testing |
| 5.3.2.1(Rated operational voltage) |
- |
2000 |
|
Only for internal testing |
| 5.3.2.2(Rated insulation voltage) |
- |
2000 |
|
Only for internal testing |
| 5.3.2.3(Rated impulse withstand voltage) |
- |
2000 |
|
Only for internal testing |
| 5.3.3(Currents) |
- |
2000 |
|
Only for internal testing |
| 5.3.3.2(Conventional free air thermal current) |
- |
2000 |
|
Only for internal testing |
| 5.3.3.3(Conventional enclosed thermal current) |
- |
2000 |
|
Only for internal testing |
| 5.3.3.4(Rated operational current (Ie) or rated operational power) |
- |
2000 |
|
Only for internal testing |
| 5.3.3.5(Rated uninterrupted current) |
- |
2000 |
|
Only for internal testing |
| 5.3.4(Rated frequency) |
- |
2000 |
|
Only for internal testing |
| 5.3.5(Rated duty) |
- |
2000 |
|
Only for internal testing |
| 5.3.5.2(Eight-hour duty) |
- |
1000 |
|
Only for internal testing |
| 5.3.5.3(Uninterrupted duty) |
- |
1000 |
|
Only for internal testing |
| 5.3.6.1(Ability to withstand motor switching overload currents) |
- |
2000 |
|
Only for internal testing |
| 5.3.6.2(Rated making capacity) |
- |
20000 |
|
Only for internal testing |
| 5.3.6.3(Rated breaking capacity) |
- |
10000 |
|
Only for internal testing |
| 5.3.7(Short-circuit characteristics) |
- |
5000 |
|
Only for internal testing |
| 5.3.7.1(Rated short-time withstand current) |
- |
2000 |
|
Only for internal testing |
| 5.3.7.2(Rated short-circuit making capacity) |
- |
5000 |
|
Only for internal testing |
| 5.3.7.4(Rated conditional short-circuit current) |
- |
10000 |
|
Only for internal testing |
| 5.4(Utilization category) |
- |
1000 |
|
Only for internal testing |
| 5.5(Control circuits) |
- |
2000 |
|
Only for internal testing |
| 5.6(Auxiliary circuits) |
- |
2000 |
|
Only for internal testing |
| 5.7(Relays and releases) |
- |
2000 |
|
Only for internal testing |
| 5.8(Co-ordination with short-circuit protective devices (SCPD)) |
- |
3000 |
|
Only for internal testing |
| 6.2.2(Marking) |
- |
2000 |
|
Only for internal testing |
| 6.3(Instructions for installation, operation and maintenance, decommissioning and dismantling) |
- |
2000 |
|
Only for internal testing |
| 8.1.1(General) |
- |
2000 |
|
Only for internal testing |
| 8.1.2.2(Glow wire testing) |
- |
16000 |
|
Only for internal testing |
| 8.1.7.1(General) |
- |
2000 |
|
Only for internal testing |
| 8.2.1(Operating conditions) |
- |
2000 |
|
Only for internal testing |
| 8.2.1.1(General) |
- |
2000 |
|
Only for internal testing |
| 8.2.1.2(Limits of operation of power operated equipment) |
- |
2000 |
|
Only for internal testing |
| 8.2.1.3(Limits of operation of under-voltage relays and releases) |
- |
5000 |
|
Only for internal testing |
| 8.2.1.4(Limits of operation of shunt releases) |
- |
5000 |
|
Only for internal testing |
| 8.2.2(Temperature-rise) |
- |
20000 |
|
Only for internal testing |
| 8.2.3(Dielectric properties) |
- |
20000 |
|
Only for internal testing |
| 8.2.3.2(Impulse withstand voltage) |
- |
10000 |
|
Only for internal testing |
| 8.2.3.3(Power-frequency or DC withstand voltage of the main, auxiliary and control circuits) |
- |
2000 |
|
Only for internal testing |
| 8.2.4(Ability to make and break under no-load, normal load and overload conditions) |
- |
2000 |
|
Only for internal testing |
| 8.2.4.1(Making and breaking capacities) |
- |
4000 |
|
Only for internal testing |
| 8.2.4.2(Operational performance) |
- |
20000 |
|
Only for internal testing |
| 8.2.4.3(Mechanical durability) |
- |
30000 |
|
Only for internal testing |
| 8.2.4.4(Electrical durability) |
- |
40000 |
|
Only for internal testing |
| 8.2.5(Ability to make, break or withstand short-circuit currents) |
- |
10000 |
|
Only for internal testing |
| 8.2.7(Additional performance requirements for equipment suitable for isolation) |
- |
10000 |
|
Only for internal testing |
| 8.2.8(Critical load current performance: DC equipment) |
- |
10000 |
|
Only for internal testing |
| 8.2.9(Overload requirements for equipment incorporating fuses) |
- |
20000 |
|
Only for internal testing |
| 9.1.3.2(Mechanical operation test) |
- |
30000 |
|
Only for internal testing |
| 9.1.3.3(Dielectric test) |
- |
10000 |
|
Only for internal testing |
| 9.1.4(Sampling tests) |
- |
5000 |
|
Only for internal testing |
| 9.1.5Special tests(Special tests) |
- |
10000 |
|
Only for internal testing |
| 9.2(Compliance with constructional requirements) |
- |
2000 |
|
Only for internal testing |
| 9.3.3.6(DC test current ripple) |
- |
2000 |
|
Only for internal testing |
| 9.3.4.2(Temperature-rise) |
- |
20000 |
|
Only for internal testing |
| 9.3.4.3(Test of dielectric properties) |
- |
20000 |
|
Only for internal testing |
| 9.3.4.4(Making and breaking capacities) |
- |
40000 |
|
Only for internal testing |
| 9.3.4.4.3(Characteristics of transient recovery voltage) |
- |
2000 |
|
Only for internal testing |
| 9.3.4.5(Dielectric verification) |
- |
8000 |
|
Only for internal testing |
| 9.3.4.6(Leakage current) |
- |
5000 |
|
Only for internal testing |
| 9.3.5.2(Operational performance test) |
- |
15000 |
|
Only for internal testing |
| 9.3.6.2(Short-time withstand current test) |
- |
10000 |
|
Only for internal testing |
| 9.3.6.3(Short-circuit making capacity test) |
- |
30000 |
|
Only for internal testing |
| 9.3.7.2(Circuit-breaker protected short-circuit withstand) |
- |
5000 |
|
Only for internal testing |
| 9.3.7.3(Fuse protected short-circuit withstand) |
- |
5000 |
|
Only for internal testing |
| 9.3.8.2(Overload test) |
- |
10000 |
|
Only for internal testing |
| 9.3.9.2(Determination of critical load current) |
- |
2000 |
|
Only for internal testing |
| 8.3(Electromagnetic compatibility tests) |
- |
2000 |
|
Only for internal testing |
| 9.5.2(Mechanical durability) |
- |
15000 |
|
Only for internal testing |
| 9.5.3(Electrical durability) |
- |
30000 |
|
Only for internal testing |
| D.7.1.1(Ambient air temperature) |
- |
20000 |
|
Only for internal testing |
| D.8.1.4(Clearances and creepage distances) |
- |
10000 |
|
Only for internal testing |
| D.8.1.12(Degrees of protection of enclosed equipment) |
- |
30000 |
|
Only for internal testing |
| D.9.3.10(Thermal cycling test) |
- |
1000 |
|
Only for internal testing |
| D.9.3.11(Climatic test) |
- |
10000 |
|
Only for internal testing |
| D.9.3.12(Temperature-rise verification with solar effects – Outdoor units only) |
- |
20000 |
|
Only for internal testing |
| E.9.2(Current cycling test) |
- |
10000 |
|
Only for internal testing |
| E.9.2.4(Temperature measurements) |
- |
20000 |
|
Only for internal testing |
| E.9.3.1(Flexion test) |
- |
10000 |
|
Only for internal testing |
| E.9.3.2(Pull-out test) |
- |
10000 |
|
Only for internal testing |
| 8.1.7.2(Additional constructional requirements) |
- |
2000 |
|
Only for internal testing |
| 8.1.9(Additional requirements for equipment provided with a neutral pol) |
- |
2000 |
|
Only for internal testing |
| 9.3.4.7(Temperature-rise verification) |
- |
15000 |
|
Only for internal testing |
| 9.3.4.8(Strength of actuator mechanism) |
- |
10000 |
|
Only for internal testing |
| 9.3.5.3(Dielectric verification) |
- |
10000 |
|
Only for internal testing |
| 9.3.5.5(Temperature-rise verification) |
- |
15000 |
|
Only for internal testing |
| 9.3.6.4(Dielectric verification) |
- |
10000 |
|
Only for internal testing |
| 9.3.6.6(Temperature-rise verification) |
- |
15000 |
|
Only for internal testing |
| 9.3.7.4(Dielectric verification) |
- |
10000 |
|
Only for internal testing |
| 9.3.7.6(Temperature-rise verification) |
- |
15000 |
|
Only for internal testing |
| 9.3.8.3(Dielectric verification) |
- |
10000 |
|
Only for internal testing |
| 9.3.8.5(Temperature-rise verification) |
- |
15000 |
|
Only for internal testing |
| 9.3.9.3(Critical load current performance) |
- |
2000 |
|
Only for internal testing |
| 9.3.5.4(Leakage current) |
- |
10000 |
|
Only for internal testing |
| 9.3.6.5(Leakage current) |
- |
10000 |
|
Only for internal testing |
| 9.3.7.5(Leakage current) |
- |
10000 |
|
Only for internal testing |
| 9.3.8.4(Leakage current) |
- |
10000 |
|
Only for internal testing |
| 8.3.2(Immunity) |
- |
2000 |
|
Only for internal testing |
| 8.3.3(Emission) |
- |
2000 |
|
Only for internal testing |
| 9.5.4(Damp heat, salt mist, vibration and shock) |
- |
10000 |
|
Only for internal testing |
| 7(Normal service, mounting and transport conditions) |
- |
1000 |
|
Only for internal testing |
| 9.1.3.2(Mechanical operation test) |
- |
10000 |
|
Only for internal testing |
|
05 Jun, 2028 |
- Included w.e.f 23.06.2025 Restricted only for Sequence I, II, V & VI. Excluding Cl. 8.3 (Electromagnetic compatibility (EMC)), Cl. 9.3.6 (short-circuit performance capability), Cl. 9.3.7 (conditional short-circuit current), Cl. 9.3.4 (Performance under short-circuit conditions), Cl. 9.4 (EMC tests), 9.3.9.2 (Determination of critical load current), 8.2.8 (Critical load current performance: DC equipment) |
| 4468 |
BIS, Central Laboratory (CL)
| None
| IS 1538 (1993) |
Cast iron fittings for pressure pipes for water, gas and sewage - Specification (Third Revision) |
- |
Rs 2700/- View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 5.1 (tensile strength) |
- |
|
|
|
| 6.1 (Brinell hardness tests) |
- |
|
|
|
| 8 (Hydrostatic Test) |
- |
|
|
|
| 9.1,Table 2 & 3 (DI) |
- |
|
|
|
| 9.1,Table 2 & 3 (P) |
- |
|
|
|
| 9.1,Table 2 & 3 (g) |
- |
|
|
|
| 9.1,Table 2 & 3 (h) |
- |
|
|
|
| 9.1,Table 2 & 3 (K) |
- |
|
|
|
| 9.1,Table 2 & 3 (L) |
- |
|
|
|
| 9.1,Table 2 & 3 (M) |
- |
|
|
|
| 9.1,Table 2 & 3 (N) |
- |
|
|
|
| 9.1,Table 2 & 3 (f) |
- |
|
|
|
| 9.1,Table 4 (D) |
- |
|
|
|
| 9.1,Table 4 (a) |
- |
|
|
|
| 9.1,Table 4 (b) |
- |
|
|
|
| 9.1,Table 4 (s) |
- |
|
|
|
| 9.1,Table 4 (r) |
- |
|
|
|
| 9.1,Table 5 (D) |
- |
|
|
|
| 9.1,Table 5 (g) |
- |
|
|
|
| 9.1,Table 5 (a) |
- |
|
|
|
| 9.1,Table 5 (b) |
- |
|
|
|
| 9.1,Table 5 (c) |
- |
|
|
|
| 9.1,Table 5 (f) |
- |
|
|
|
| 9.1,Table 5 (s) |
- |
|
|
|
| 9.1,Table 5 (C) |
- |
|
|
|
| 9.1,Table 5 (Holes No) |
- |
|
|
|
| 9.1,Table 5 (Holes diameter) |
- |
|
|
|
| 9.1,Table 6 (Diameterof Bolts) |
- |
|
|
|
| 9.1&11.1,Table 7,8&9 (e) |
- |
|
|
|
| 9.1&11.1,Table 7,8&9 (l) |
- |
|
|
|
| 9.1&11.1,Table 7,8&9 (Mass (Approx)) |
- |
|
|
|
| 9.1&11.1,Table 10 to13 (e) |
- |
|
|
|
| 9.1&11.1,Table 10 to13 (a) |
- |
|
|
|
| 9.1&11.1,Table 10 to13 (r) |
- |
|
|
|
| 9.1&11.1,Table 10 to13 (b) |
- |
|
|
|
| 9.1&11.1,Table 10 to13 (Mass (Approx)) |
- |
|
|
|
| 9.1&11.1,Table 14 (Nominal Diameter) |
- |
|
|
|
| 9.1&11.1,Table 14 (e1) |
- |
|
|
|
| 9.1&11.1,Table 14 (e) |
- |
|
|
|
| 9.1&11.1,Table 14 (l) |
- |
|
|
|
| 9.1&11.1,Table 14 (h) |
- |
|
|
|
| 9.1&11.1,Table 14 (Mass (Approx)) |
- |
|
|
|
| 9.1&11.1,Table 15 (e) |
- |
|
|
|
| 9.1&11.1,Table 15 (l) |
- |
|
|
|
| 9.1&11.1,Table 15 (Nominal Diameter) |
- |
|
|
|
| 9.1&11.1,Table 15 (e1) |
- |
|
|
|
| 9.1&11.1,Table 15 (k) |
- |
|
|
|
| 9.1&11.1,Table 15 (Mass (Approx)) |
- |
|
|
|
| 9.1&11.1,Table 16 (e) |
- |
|
|
|
| 9.1&11.1,Table 16 (l) |
- |
|
|
|
| 9.1&11.1,Table 16 (h) |
- |
|
|
|
| 9.1&11.1,Table 16 (Mass (Approx)) |
- |
|
|
|
| 9.1&11.1,Table 17 (e1) |
- |
|
|
|
| 9.1&11.1,Table 17 (l1) |
- |
|
|
|
| 9.1&11.1,Table 17 (Nominal Diameter) |
- |
|
|
|
| 9.1&11.1,Table 17 (e2) |
- |
|
|
|
| 9.1&11.1,Table 17 (l2) |
- |
|
|
|
| 9.1&11.1,Table 17 (l3) |
- |
|
|
|
| 9.1&11.1,Table 17 (l) |
- |
|
|
|
| 9.1&11.1,Table 17 (Mass) |
- |
|
|
|
| 9.1&11.1,Table 18 (a) |
- |
|
|
|
| 9.1&11.1,Table 18 (P) |
- |
|
|
|
| 9.1&11.1,Table 18 (Mass (Approx)) |
- |
|
|
|
| 9.1&11.1,Table 19 (DC) |
- |
|
|
|
| 9.1&11.1,Table 19 (e) |
- |
|
|
|
| 9.1&11.1,Table 19 (a) |
- |
|
|
|
| 9.1&11.1,Table 19 (l) |
- |
|
|
|
| 9.1&11.1,Table 19 (Mass (Approx)) |
- |
|
|
|
| 9.1&11.1,Table 20 (DI) |
- |
|
|
|
| 9.1&11.1,Table 20 (h) |
- |
|
|
|
| 9.1&11.1,Table 20 (Mass (Approx)) |
- |
|
|
|
| 9.1&11.1,Table 21 (e) |
- |
|
|
|
| 9.1&11.1,Table 21 (r) |
- |
|
|
|
| 9.1&11.1,Table 21 (a) |
- |
|
|
|
| 9.1&11.1,Table 21 (b) |
- |
|
|
|
| 9.1&11.1,Table 21 (Mass (Approx)) |
- |
|
|
|
| 9.1&11.1,Table 22 (e) |
- |
|
|
|
| 9.1&11.1,Table 22 (r) |
- |
|
|
|
| 9.1&11.1,Table 22 (a) |
- |
|
|
|
| 9.1&11.1,Table 22 (b) |
- |
|
|
|
| 9.1&11.1,Table 22 (c) |
- |
|
|
|
| 9.1&11.1,Table 22 (a) |
- |
|
|
|
| 9.1&11.1,Table 22 (f) |
- |
|
|
|
| 9.1&11.1,Table 22 (g) |
- |
|
|
|
| 12.1 to 12.7 (Coating ) |
- |
|
|
|
|
- |
- - |
| 4469 |
Havells India Limited (Havells Research & Development Laboratory)
| 8187226
| IS/IEC 60947 : PART 3 (2020) |
Low-Voltage Switchgear and Controlgear: Part 3 Switches Disconnectors Switch-Disconnectors and Fuse-Combination Units |
Switches, Disconnectors, Switch- Disconnectors and Fuse-Combination Units |
2593000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 3.1(General) |
- |
0 |
|
Only for internal testing |
| 4(Classification) |
- |
10000 |
|
Only for internal testing |
| 5.3.2(Rated voltages) |
- |
0 |
|
Only for internal testing |
| 5.3.2.1(Rated operational voltage) |
- |
0 |
|
Only for internal testing |
| 5.3.2.2(Rated insulation voltage) |
- |
0 |
|
Only for internal testing |
| 5.3.2.3(Rated impulse withstand voltage) |
- |
0 |
|
Only for internal testing |
| 5.3.3(Currents) |
- |
0 |
|
Only for internal testing |
| 5.3.3.2(Conventional free air thermal current) |
- |
0 |
|
Only for internal testing |
| 5.3.3.3(Conventional enclosed thermal current) |
- |
0 |
|
Only for internal testing |
| 5.3.3.4(Rated operational current (Ie) or rated operational power) |
- |
0 |
|
Only for internal testing |
| 5.3.3.5(Rated uninterrupted current) |
- |
0 |
|
Only for internal testing |
| 5.3.4(Rated frequency) |
- |
0 |
|
Only for internal testing |
| 5.3.5(Rated duty) |
- |
0 |
|
Only for internal testing |
| 5.3.5.2(Eight-hour duty) |
- |
0 |
|
Only for internal testing |
| 5.3.5.3(Uninterrupted duty) |
- |
0 |
|
Only for internal testing |
| 5.3.6.1(Ability to withstand motor switching overload currents) |
- |
0 |
|
Only for internal testing |
| 5.3.6.2(Rated making capacity) |
- |
0 |
|
Only for internal testing |
| 5.3.6.3(Rated breaking capacity) |
- |
0 |
|
Only for internal testing |
| 5.3.7(Short-circuit characteristics) |
- |
0 |
|
Only for internal testing |
| 5.3.7.1(Rated short-time withstand current) |
- |
0 |
|
Only for internal testing |
| 5.3.7.2(Rated short-circuit making capacity) |
- |
0 |
|
Only for internal testing |
| 5.3.7.4(Rated conditional short-circuit current) |
- |
0 |
|
Only for internal testing |
| 5.4(Utilization category) |
- |
0 |
|
Only for internal testing |
| 5.5(Control circuits) |
- |
0 |
|
Only for internal testing |
| 5.6(Auxiliary circuits) |
- |
0 |
|
Only for internal testing |
| 5.7(Relays and releases) |
- |
0 |
|
Only for internal testing |
| 5.8(Co-ordination with short-circuit protective devices (SCPD)) |
- |
0 |
|
Only for internal testing |
| 6.2.2(Marking) |
- |
0 |
|
Only for internal testing |
| 6.3(Instructions for installation, operation and maintenance, decommissioning and dismantling) |
- |
0 |
|
Only for internal testing |
| 7(Normal service, mounting and transport conditions) |
- |
0 |
|
Only for internal testing |
| 8.1.1(General) |
- |
0 |
|
Only for internal testing |
| 8.1.2.2(Glow wire testing) |
- |
60000 |
|
Only for internal testing |
| 8.1.7.1(General) |
- |
0 |
|
Only for internal testing |
| 8.2.1(Operating conditions) |
- |
20000 |
|
Only for internal testing |
| 8.2.1.1(General) |
- |
0 |
|
Only for internal testing |
| 8.2.2(Temperature-rise) |
- |
25000 |
|
Only for internal testing |
| 8.2.3(Dielectric properties) |
- |
20000 |
|
Only for internal testing |
| 8.2.3.2(Impulse withstand voltage) |
- |
15000 |
|
Only for internal testing |
| 8.2.3.3(Power-frequency or DC withstand voltage of the main, auxiliary and control circuits) |
- |
0 |
|
Only for internal testing |
| 8.2.4(Ability to make and break under no-load, normal load and overload conditions) |
- |
50000 |
|
Only for internal testing |
| 8.2.4.1(Making and breaking capacities) |
- |
50000 |
|
Only for internal testing |
| 8.2.4.2(Operational performance) |
- |
100000 |
|
Only for internal testing |
| 8.2.4.3(Mechanical durability) |
- |
90000 |
|
Only for internal testing |
| 8.2.4.4(Electrical durability) |
- |
90000 |
|
Only for internal testing |
| 8.2.5(Ability to make, break or withstand short-circuit currents) |
- |
200000 |
|
Only for internal testing as per each rating |
| 8.2.7(Additional performance requirements for equipment suitable for isolation) |
- |
0 |
|
Only for internal testing |
| 8.2.9(Overload requirements for equipment incorporating fuses) |
- |
0 |
|
Only for internal testing |
| 9.1.3.2(Mechanical operation test) |
- |
90000 |
|
Only for internal testing |
| 9.1.3.3(Dielectric test) |
- |
65000 |
|
Only for internal testing |
| 9.1.5Special tests(Special tests) |
- |
100000 |
|
Only for internal testing |
| 9.2(Compliance with constructional requirements) |
- |
40000 |
|
Only for internal testing |
| 9.3.4.2(Temperature-rise) |
- |
25000 |
|
Only for internal testing |
| 9.3.4.3(Test of dielectric properties) |
- |
65000 |
|
Only for internal testing |
| 9.3.4.4(Making and breaking capacities) |
- |
60000 |
|
Only for internal testing |
| 9.3.4.4.3(Characteristics of transient recovery voltage) |
- |
0 |
|
Only for internal testing |
| 9.3.4.5(Dielectric verification) |
- |
28000 |
|
Only for internal testing |
| 9.3.4.6(Leakage current) |
- |
25000 |
|
Only for internal testing |
| 9.3.5.2(Operational performance test) |
- |
50000 |
|
Only for internal testing |
| 9.3.6.2(Short-time withstand current test) |
- |
200000 |
|
Only for internal testing as per each rating |
| 9.3.6.3(Short-circuit making capacity test) |
- |
200000 |
|
Only for internal testing as per each rating |
| 9.3.7.3(Fuse protected short-circuit withstand) |
- |
200000 |
|
Only for internal testing as per each rating |
| 9.3.8.2(Overload test) |
- |
60000 |
|
Only for internal testing |
| 9.3.9.2(Determination of critical load current) |
- |
50000 |
|
Only for internal testing |
| 9.5.2(Mechanical durability) |
- |
40000 |
|
Only for internal testing |
| 9.5.3(Electrical durability) |
- |
70000 |
|
Only for internal testing |
| 8.1.7.2(Additional constructional requirements) |
- |
40000 |
|
Only for internal testing |
| 8.1.9(Additional requirements for equipment provided with a neutral pol) |
- |
40000 |
|
Only for internal testing |
| 9.3.4.7(Temperature-rise verification) |
- |
25000 |
|
Only for internal testing |
| 9.3.4.8(Strength of actuator mechanism) |
- |
20000 |
|
Only for internal testing |
| 9.3.5.3(Dielectric verification) |
- |
30000 |
|
Only for internal testing |
| 9.3.5.5(Temperature-rise verification) |
- |
25000 |
|
Only for internal testing |
| 9.3.6.4(Dielectric verification) |
- |
30000 |
|
Only for internal testing |
| 9.3.6.6(Temperature-rise verification) |
- |
25000 |
|
Only for internal testing |
| 9.3.7.4(Dielectric verification) |
- |
30000 |
|
Only for internal testing |
| 9.3.7.6(Temperature-rise verification) |
- |
25000 |
|
Only for internal testing |
| 9.3.8.3(Dielectric verification) |
- |
30000 |
|
Only for internal testing |
| 9.3.8.5(Temperature-rise verification) |
- |
25000 |
|
Only for internal testing |
| 9.3.5.4(Leakage current) |
- |
25000 |
|
Only for internal testing |
| 9.3.6.5(Leakage current) |
- |
25000 |
|
Only for internal testing |
| 9.3.7.5(Leakage current) |
- |
25000 |
|
Only for internal testing |
| 9.3.8.4(Leakage current) |
- |
25000 |
|
Only for internal testing |
| 9.1.3.2(Mechanical operation test) |
- |
70000 |
|
Only for internal testing |
|
07 Aug, 2028 |
- - |
| 4470 |
CIPET. MYSURU
| 6113734
| IS 13487 (1992) |
Irrigation equipment - Emitters - Specification |
- |
6150 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 7.1(Construction and workmanship) |
- |
225 |
|
Construction and workmanship |
| 7.2(Flow path in emitters) |
- |
225 |
|
Flow path in the emitter |
| 7.3.1(Resistance to Hydrostatic pressure) |
- |
750 |
|
Resistance to Hydrostatic pressure |
| 7.3.2(Resistance to Hydrostatic pressure) |
- |
750 |
|
Resistance to Hydrostatic pressure |
| 7.4.1(Emitter Pull Out In-line emitters) |
- |
750 |
|
Emitter Pull Out In-line emitters |
| 8.1.2(Uniformity of Emission Rate Unregulated emitters) |
- |
750 |
|
Uniformity of Emission Rate Unregulated emitters |
| 8.1.3(Uniformity of Emission Rate Regulated emitters) |
- |
749.98 |
|
Uniformity of Emission Rate Regulated emitters |
| 8.2.2(Emission rate as a function of inlet pressure Unregulated emitters) |
- |
750 |
|
Emission rate as a function of inlet pressure Unregulated emitters |
| 8.2.3(Emission rate as a function of inlet pressure Regulated emitters) |
- |
750 |
|
Emission rate as a function of inlet pressure Regulated emitters |
| 8.3(Determination of Emitter Exponent) |
- |
450 |
|
Determination of Emitter Exponent |
|
31 Dec, 2026 |
- - |