| 4501 |
Atmy Analytical Labs Private Limited (Unit-2), Greater Noida
| 8176106
| IS 14203 (2023) |
FIRE RESISTING RECORD PROTECTION CABINETS SPECIFICATION Second Revision of IS 14203 |
- |
339000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 3 and 6 (Table 1)(Nominal Sizes - Height) |
- |
0 |
|
- |
| 3 and 6 (Table 1)(Nominal Sizes - Width) |
- |
0 |
|
- |
| 3 and 6 (Table 1)(Nominal Sizes - Depth) |
- |
0 |
|
- |
| 3 and 6 (Table 1)(Height of Pedestal) |
- |
0 |
|
- |
| 7(Designation) |
- |
0 |
|
- |
| 8.1(Cabinet Construction) |
- |
0 |
|
- |
| 8.2(Locking Mechanism) |
- |
0 |
|
- |
| 8.3(Locks) |
- |
0 |
|
- |
| 8.4(Handles) |
- |
0 |
|
- |
| 9(Internal Fixtures) |
- |
0 |
|
- |
| 10.1(Minimum overall thinckness of coating) |
- |
0 |
|
- |
| 10.2(Cross Hatch Test) |
- |
0 |
|
- |
| 11, Annex-B, 3.1(Fire Endurance Test) |
- |
0 |
|
- |
| 11, Annex-B, 3.2(Fire and Impact test) |
- |
0 |
|
- |
|
08 Feb, 2027 |
- Included w.e.f. 01.04.2025 |
| 4502 |
Atmy Analytical Labs Private Limited (Unit-2), Greater Noida
| 8176106
| IS 14561 (2014) |
Fire resisting (Insulating) filing cabinets - Specification (Second Revision) |
ALL |
330000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 3(Types & Rating) |
- |
0 |
|
- |
| 3.1(i) The fire resisting filing cabinets shall be of two types:
a) Vertical fire resisting filing cabinet, and
b) Lateral fire resisting filing cabinet.) |
- |
0 |
|
- |
| 3.2(ii) The standard and lateral fire resisting filing
cabinets shall have one-drawer or two-drawers or three drawers or four-drawers. A typical drawing of the fire resisting filing cabinet is given in Fig. 1.) |
- |
0 |
|
- |
| 3.3(iii) The fire resisting filing cabinets shall have fire
resisting ratings of 60 min or 120 min or 180 min or
240 min) |
- |
0 |
|
- |
| 4(Dimensions and Tolerances, mm) |
- |
0 |
|
- |
| 4.1(Overall Dimensions of Fire Resisting Filing
Cabinets: The internal usable space of the drawers of fire resisting (insulating) filing cabinets shall be as specified in Table 1 or any other size which is mutually agreed to between the purchaser and the supplier.) |
- |
0 |
|
- |
| 4.1(Internal usuable space of drawer, mm:) |
- |
0 |
|
- |
| 4.1(i) Height) |
- |
0 |
|
- |
| 4.1(ii) Width) |
- |
0 |
|
- |
| 4.1(iii) Depth) |
- |
0 |
|
- |
| 4.1(iv) Height of the bottom drawer above floor level) |
- |
0 |
|
- |
| 5(Materials) |
- |
0 |
|
- |
| 6(Designations: The filing cabinet shall be designated by the commonly used name, type, the fire rating and the number of this Indian Standard.) |
- |
0 |
|
- |
| 7(Constructions) |
- |
0 |
|
- |
| 7.1(Outer body and Inner Box: Outer body and inner box shall be fabricated from mild steel or galvanized steel sheets of not less than 0.8 mm and not more than 1.2 mm nominal thickness. The steel shall not have any burrs or dents. If required the outer
body shall be suitably stiffened to avoid bulging) |
- |
0 |
|
- |
| 7.2(Cabinets Sub-Assembly: The external body and drawer fronts of the fire resisting (insulating) filing cabinet shall be of double wall type with homogeneous insulating material filled in
between. Further the construction of the cabinet shall be such that each drawer slides in an individual inner box. The inner boxes shall have a insulating layer between each other to prevent fire spreading from one drawer to another. The joining of inner box, intermediate piece and outer body shall be such that, it forms a cavity to receive drawer front ) |
- |
0 |
|
- |
| 7.3(Filing Drawer: The drawer shall be made from mild steel or galvanized steel sheet of not less than 0.6 mm and not more than 1.0 mm nominal thickness and shall have an arrangement on the sides suitable for the drawer suspension system and an arrangement to stop it when fully pushed in.) |
- |
0 |
|
- |
| 7.3.1(Drawer Front: The drawer front shall be made from mild steel or galvanized steel sheet of not less than 0.6 mm and not more than 1.0 mm nominal thickness and shall be firmly secured to the drawer body by welding, screwing or riveting or any combination of these processes. The construction of drawer front shall be such that it snugly fits in the cavity provided for the same ) |
- |
0 |
|
- |
| 7.4.1(Latch: Each drawer of the cabinet shall be removable but shall be fitted with a latch/positive stop to prevent inadvertent withdrawal and rebound. Such latch shall be lifted/unlocked by the pull of the handle or any other mechanism.) |
- |
0 |
|
- |
| 7.4.2(The locking mechanism shall be designed in such
a manner so that there is minimum passage for direct
conduction of heat from outside to inside) |
- |
0 |
|
- |
| 7.5(Drawer Suspension The drawer suspension shall be either of the following types to ensure withdrawal of the full depth of the drawer:
a) Ball bearing / Roller bearing suspension
(Movement),
b) Solid roller suspension, and
c) Telescopic slide suspension (Extension) |
- |
0 |
|
- |
| 7.6(Handles: Each drawer shall be provided either with a handle made from ferrous/non-ferrous material suitably coated for corrosion resistance, or any polymer and fixed to the front of the drawer or with a built in pulling mechanism) |
- |
0 |
|
- |
| 7.6.1(The drawer handle shall be strong enough to take
a minimum pull of 50 N for 2 min. There shall be no
sharp corners or edges to avoid injury and damage to clothing) |
- |
0 |
|
- |
| 7.7.1(Locks: Top drawer shall be provided with single or dual control key lock having not less than 6 levers or pin cylinder lock having not less than 6 pins, with duplicate keys of stainless steel/nonferrous alloy. Alternatively if required by the purchaser a 3 wheel combination lock or electronic combination lock may be provided either in place of key lock or in addition to key lock) |
- |
0 |
|
- |
| 7.7.2(Each drawer may also be provided with
individual key lock or pin cylinder lock or combination lock subject to agreement between the purchaser and the supplier.) |
- |
0 |
|
- |
| 7.8(Locking Mechanism ) |
- |
0 |
|
- |
| 7.8.1(The locking mechanism shall be such that when
the top drawer is pushed-in fully, it actuates locking
mechanism to lock all other drawers imultaneously,
when they are in pushed-in position) |
- |
0 |
|
- |
| 7.8.1.1(At the time of locking the cabinet, if one of the
drawers is not fully pushed-in, that drawer shall remain unlocked and can be used. As soon as that drawer is pushed-in fully, it shall get locked automatically without further operation of key by the user.) |
- |
0 |
|
- |
| 7.8.1.2(In addition to the above, isolation mechanism
shall also be provided to permit independent locking/ use of other drawers. Such isolation mechanism provided on drawers shall be manually operated) |
- |
0 |
|
- |
| 8(Assemblies) |
- |
0 |
|
- |
| 8.1(The components shall be assembled by bolting,
welding, riveting or by any combination of these
processes) |
- |
0 |
|
- |
| 8.2(All joints between outer body and inner boxes,
the drawer front and the outer body shall be such that, there is minimum direct conduction of heat from outer body to inner body) |
- |
0 |
|
- |
| 9.1(Drawer Suspension Test and Latch Test: The drawer loaded with evenly distributed load of 30 kg
(excluding the weight of drawer) in any drawer shall be operated for 5 000 cycles at a rate of 300 cycles/h ±10 percent. One opening and one closing shall constitute one cycle. The test shall be carried out with maximum two breaks by using electrically or mechanically operated test equipment with a counter fitted on it. After 5 000 cycles the suspension slide and latch mechanism shall not show any apparent distortion, cracks, or failures to operate in a normal smooth manner) |
- |
0 |
|
- |
| 10.1(Finish: All dents, burrs and sharp edges shall be removed from the various components and they shall be thoroughly degreased and cleaned of rust and scale) |
- |
0 |
|
- |
| 10.2(The inside and outside surfaces of the fire resisting
(Insulating) filing cabinet shall be painted or powder coated. In case of paint, an appropriate primer and undercoating shall be used in accordance to industry practices. The minimum overall thickness of the coatings shall be 50 μ for powder coating and 70 μ for liquid paint. Cross hatch test shall be conducted to confirm the adhesion of coating in accordance with 10.2.1) |
- |
0 |
|
- |
| 10.2.1(Cross Hatch Test) |
- |
0 |
|
- |
| 10.2.1(a) Make 6 parallel cut marks using sharp metal
pointer and straight edge, through the painted/
coated surface, so as to make the base surface
visible through cut marks) |
- |
0 |
|
- |
| 10.2.1(b) Cut marks shall be minimum 20 mm long and
at 2 mm distance from each other) |
- |
0 |
|
- |
| 10.2.1(c) Make 6 similar cut marks in the direction
perpendicular to first set of cut marks, with
same length and spacing) |
- |
0 |
|
- |
| 10.2.1(d) These 12 cut marks together shall make a
pattern of 25 squares of 2 mm × 2mm size,
totally separated from each other) |
- |
0 |
|
- |
| 10.2.1(f) To ensure continuous contact with paint/coat
film, rub the tape firmly and remove air
bubbles under the tape, if any) |
- |
0 |
|
- |
| 10.2.1(g)Within 60 to 120 s after sticking the tape,
remove it by seizing free end of the tape and
rapidly pulling it off at an angle close to 180°.) |
- |
0 |
|
- |
| 10.2.1(h) Painting/Coating quality is considered as
acceptable, if no part of any 2 mm × 2 mm
square of paint/coat comes off the surface due
to pulling the tape) |
- |
0 |
|
- |
| 11.1(Fire endurance test) |
- |
0 |
|
- |
| 11.2(Fire and impact test) |
- |
0 |
|
- |
| 12.1(Marking of Cabinets:A metal plate showing classification of cabinet together with the manufacturer’s name, serial number and the
year of manufacture shall be fixed inside surface of
the top drawer of the cabinet in such a way that it is
visible when it is opened.) |
- |
0 |
|
- |
| 12.2(Marking on Keys: The keys shall bear an identification number which shall not be the same as the serial number of the cabinet) |
- |
0 |
|
- |
| 3(Types & Rating) |
- |
0 |
|
- |
| 3.1(i) The fire resisting filing cabinets shall be of two types:
a) Vertical fire resisting filing cabinet, and
b) Lateral fire resisting filing cabinet.) |
- |
0 |
|
- |
| 3.2(ii) The standard and lateral fire resisting filing
cabinets shall have one-drawer or two-drawers or three drawers or four-drawers. A typical drawing of the fire resisting filing cabinet is given in Fig. 1.) |
- |
0 |
|
- |
| 3.3(iii) The fire resisting filing cabinets shall have fire
resisting ratings of 60 min or 120 min or 180 min or
240 min) |
- |
0 |
|
- |
| 4(Dimensions and Tolerances, mm) |
- |
0 |
|
- |
| 4.1(Overall Dimensions of Fire Resisting Filing
Cabinets: The internal usable space of the drawers of fire resisting (insulating) filing cabinets shall be as specified in Table 1 or any other size which is mutually agreed to between the purchaser and the supplier.) |
- |
0 |
|
- |
| 4.1(Internal usuable space of drawer, mm:) |
- |
0 |
|
- |
| 4.1(i) Height) |
- |
0 |
|
- |
| 4.1(ii) Width) |
- |
0 |
|
- |
| 4.1(iii) Depth) |
- |
0 |
|
- |
| 4.1(iv) Height of the bottom drawer above floor level) |
- |
0 |
|
- |
| 5(Materials) |
- |
0 |
|
- |
| 6(Designations: The filing cabinet shall be designated by the commonly used name, type, the fire rating and the number of this Indian Standard.) |
- |
0 |
|
- |
| 7(Constructions) |
- |
0 |
|
- |
| 7.1(Outer body and Inner Box: Outer body and inner box shall be fabricated from mild steel or galvanized steel sheets of not less than 0.8 mm and not more than 1.2 mm nominal thickness. The steel shall not have any burrs or dents. If required the outer
body shall be suitably stiffened to avoid bulging) |
- |
0 |
|
- |
| 7.2(Cabinets Sub-Assembly: The external body and drawer fronts of the fire resisting (insulating) filing cabinet shall be of double wall type with homogeneous insulating material filled in
between. Further the construction of the cabinet shall be such that each drawer slides in an individual inner box. The inner boxes shall have a insulating layer between each other to prevent fire spreading from one drawer to another. The joining of inner box, intermediate piece and outer body shall be such that, it forms a cavity to receive drawer front ) |
- |
0 |
|
- |
| 7.3(Filing Drawer: The drawer shall be made from mild steel or galvanized steel sheet of not less than 0.6 mm and not more than 1.0 mm nominal thickness and shall have an arrangement on the sides suitable for the drawer suspension system and an arrangement to stop it when fully pushed in.) |
- |
0 |
|
- |
| 7.3.1(Drawer Front: The drawer front shall be made from mild steel or galvanized steel sheet of not less than 0.6 mm and not more than 1.0 mm nominal thickness and shall be firmly secured to the drawer body by welding, screwing or riveting or any combination of these processes. The construction of drawer front shall be such that it snugly fits in the cavity provided for the same ) |
- |
0 |
|
- |
| 7.4.1(Latch: Each drawer of the cabinet shall be removable but shall be fitted with a latch/positive stop to prevent inadvertent withdrawal and rebound. Such latch shall be lifted/unlocked by the pull of the handle or any other mechanism.) |
- |
0 |
|
- |
| 7.4.2(The locking mechanism shall be designed in such
a manner so that there is minimum passage for direct
conduction of heat from outside to inside) |
- |
0 |
|
- |
| 7.5(Drawer Suspension The drawer suspension shall be either of the following types to ensure withdrawal of the full depth of the drawer:
a) Ball bearing / Roller bearing suspension
(Movement),
b) Solid roller suspension, and
c) Telescopic slide suspension (Extension) |
- |
0 |
|
- |
| 7.6(Handles: Each drawer shall be provided either with a handle made from ferrous/non-ferrous material suitably coated for corrosion resistance, or any polymer and fixed to the front of the drawer or with a built in pulling mechanism) |
- |
0 |
|
- |
| 7.6.1(The drawer handle shall be strong enough to take
a minimum pull of 50 N for 2 min. There shall be no
sharp corners or edges to avoid injury and damage to clothing) |
- |
0 |
|
- |
| 7.7.1(Locks: Top drawer shall be provided with single or dual control key lock having not less than 6 levers or pin cylinder lock having not less than 6 pins, with duplicate keys of stainless steel/nonferrous alloy. Alternatively if required by the purchaser a 3 wheel combination lock or electronic combination lock may be provided either in place of key lock or in addition to key lock) |
- |
0 |
|
- |
| 7.7.2(Each drawer may also be provided with
individual key lock or pin cylinder lock or combination lock subject to agreement between the purchaser and the supplier.) |
- |
0 |
|
- |
| 7.8(Locking Mechanism ) |
- |
0 |
|
- |
| 7.8.1(The locking mechanism shall be such that when
the top drawer is pushed-in fully, it actuates locking
mechanism to lock all other drawers imultaneously,
when they are in pushed-in position) |
- |
0 |
|
- |
| 7.8.1.1(At the time of locking the cabinet, if one of the
drawers is not fully pushed-in, that drawer shall remain unlocked and can be used. As soon as that drawer is pushed-in fully, it shall get locked automatically without further operation of key by the user.) |
- |
0 |
|
- |
| 7.8.1.2(In addition to the above, isolation mechanism
shall also be provided to permit independent locking/ use of other drawers. Such isolation mechanism provided on drawers shall be manually operated) |
- |
0 |
|
- |
| 8(Assemblies) |
- |
0 |
|
- |
| 8.1(The components shall be assembled by bolting,
welding, riveting or by any combination of these
processes) |
- |
0 |
|
- |
| 8.2(All joints between outer body and inner boxes,
the drawer front and the outer body shall be such that, there is minimum direct conduction of heat from outer body to inner body) |
- |
0 |
|
- |
| 9.1(Drawer Suspension Test and Latch Test: The drawer loaded with evenly distributed load of 30 kg
(excluding the weight of drawer) in any drawer shall be operated for 5 000 cycles at a rate of 300 cycles/h ±10 percent. One opening and one closing shall constitute one cycle. The test shall be carried out with maximum two breaks by using electrically or mechanically operated test equipment with a counter fitted on it. After 5 000 cycles the suspension slide and latch mechanism shall not show any apparent distortion, cracks, or failures to operate in a normal smooth manner) |
- |
0 |
|
- |
| 10.1(Finish: All dents, burrs and sharp edges shall be removed from the various components and they shall be thoroughly degreased and cleaned of rust and scale) |
- |
0 |
|
- |
| 10.2(The inside and outside surfaces of the fire resisting
(Insulating) filing cabinet shall be painted or powder coated. In case of paint, an appropriate primer and undercoating shall be used in accordance to industry practices. The minimum overall thickness of the coatings shall be 50 μ for powder coating and 70 μ for liquid paint. Cross hatch test shall be conducted to confirm the adhesion of coating in accordance with 10.2.1) |
- |
0 |
|
- |
| 10.2.1(Cross Hatch Test) |
- |
0 |
|
- |
| 10.2.1(a) Make 6 parallel cut marks using sharp metal
pointer and straight edge, through the painted/
coated surface, so as to make the base surface
visible through cut marks) |
- |
0 |
|
- |
| 10.2.1(b) Cut marks shall be minimum 20 mm long and
at 2 mm distance from each other) |
- |
0 |
|
- |
| 10.2.1(c) Make 6 similar cut marks in the direction
perpendicular to first set of cut marks, with
same length and spacing) |
- |
0 |
|
- |
| 10.2.1(d) These 12 cut marks together shall make a
pattern of 25 squares of 2 mm × 2mm size,
totally separated from each other) |
- |
0 |
|
- |
| 10.2.1(g)Within 60 to 120 s after sticking the tape,
remove it by seizing free end of the tape and
rapidly pulling it off at an angle close to 180°.) |
- |
0 |
|
- |
| 10.2.1(h) Painting/Coating quality is considered as
acceptable, if no part of any 2 mm × 2 mm
square of paint/coat comes off the surface due
to pulling the tape) |
- |
0 |
|
- |
| 11.1(Fire endurance test) |
- |
0 |
|
- |
| 11.2(Fire and impact test) |
- |
0 |
|
- |
| 12.1(Marking of Cabinets:A metal plate showing classification of cabinet together with the manufacturer’s name, serial number and the
year of manufacture shall be fixed inside surface of
the top drawer of the cabinet in such a way that it is
visible when it is opened.) |
- |
0 |
|
- |
| 12.2(Marking on Keys: The keys shall bear an identification number which shall not be the same as the serial number of the cabinet) |
- |
0 |
|
- |
| 10.2.1(f) To ensure continuous contact with paint/coat
film, rub the tape firmly and remove air
bubbles under the tape, if any) |
- |
0 |
|
- |
|
08 Feb, 2027 |
- Included w.e.f. 01.04.2025 |
| 4503 |
Ace Test Labs & Metrology Pvt. Ltd., Sonipat
| 9162826
| IS 14561 (2014) |
Fire resisting (Insulating) filing cabinets - Specification (Second Revision) |
- |
258000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 3(Types & Rating) |
- |
5000 |
|
- |
| 3.1(i) The fire resisting filing cabinets shall be of two types:
a) Vertical fire resisting filing cabinet, and
b) Lateral fire resisting filing cabinet.) |
- |
5000 |
|
- |
| 3.2(ii) The standard and lateral fire resisting filing
cabinets shall have one-drawer or two-drawers or three drawers or four-drawers. A typical drawing of the fire resisting filing cabinet is given in Fig. 1.) |
- |
5000 |
|
- |
| 3.3(iii) The fire resisting filing cabinets shall have fire
resisting ratings of 60 min or 120 min or 180 min or
240 min) |
- |
5000 |
|
- |
| 4(Dimensions and Tolerances, mm) |
- |
5000 |
|
- |
| 4.1(Overall Dimensions of Fire Resisting Filing
Cabinets: The internal usable space of the drawers of fire resisting (insulating) filing cabinets shall be as specified in Table 1 or any other size which is mutually agreed to between the purchaser and the supplier.) |
- |
5000 |
|
- |
| 4.1(Internal usuable space of drawer, mm:) |
- |
5000 |
|
- |
| 4.1(i) Height) |
- |
5000 |
|
- |
| 4.1(ii) Width) |
- |
5000 |
|
- |
| 4.1(iii) Depth) |
- |
5000 |
|
- |
| 4.1(iv) Height of the bottom drawer above floor level) |
- |
5000 |
|
- |
| 5(Materials) |
- |
5000 |
|
- |
| 6(Designations: The filing cabinet shall be designated by the commonly used name, type, the fire rating and the number of this Indian Standard.) |
- |
5000 |
|
- |
| 7(Constructions) |
- |
15000 |
|
- |
| 7.1(Outer body and Inner Box: Outer body and inner box shall be fabricated from mild steel or galvanized steel sheets of not less than 0.8 mm and not more than 1.2 mm nominal thickness. The steel shall not have any burrs or dents. If required the outer
body shall be suitably stiffened to avoid bulging) |
- |
5000 |
|
- |
| 7.2(Cabinets Sub-Assembly: The external body and drawer fronts of the fire resisting (insulating) filing cabinet shall be of double wall type with homogeneous insulating material filled in
between. Further the construction of the cabinet shall be such that each drawer slides in an individual inner box. The inner boxes shall have a insulating layer between each other to prevent fire spreading from one drawer to another. The joining of inner box, intermediate piece and outer body shall be such that, it forms a cavity to receive drawer front ) |
- |
5000 |
|
- |
| 7.3(Filing Drawer: The drawer shall be made from mild steel or galvanized steel sheet of not less than 0.6 mm and not more than 1.0 mm nominal thickness and shall have an arrangement on the sides suitable for the drawer suspension system and an arrangement to stop it when fully pushed in.) |
- |
5000 |
|
- |
| 7.3.1(Drawer Front: The drawer front shall be made from mild steel or galvanized steel sheet of not less than 0.6 mm and not more than 1.0 mm nominal thickness and shall be firmly secured to the drawer body by welding, screwing or riveting or any combination of these processes. The construction of drawer front shall be such that it snugly fits in the cavity provided for the same ) |
- |
5000 |
|
- |
| 7.4.1(Latch: Each drawer of the cabinet shall be removable but shall be fitted with a latch/positive stop to prevent inadvertent withdrawal and rebound. Such latch shall be lifted/unlocked by the pull of the handle or any other mechanism.) |
- |
5000 |
|
- |
| 7.4.2(The locking mechanism shall be designed in such
a manner so that there is minimum passage for direct
conduction of heat from outside to inside) |
- |
5000 |
|
- |
| 7.5(Drawer Suspension The drawer suspension shall be either of the following types to ensure withdrawal of the full depth of the drawer:
a) Ball bearing / Roller bearing suspension
(Movement),
b) Solid roller suspension, and
c) Telescopic slide suspension (Extension) |
- |
5000 |
|
- |
| 7.6(Handles: Each drawer shall be provided either with a handle made from ferrous/non-ferrous material suitably coated for corrosion resistance, or any polymer and fixed to the front of the drawer or with a built in pulling mechanism) |
- |
5000 |
|
- |
| 7.6.1(The drawer handle shall be strong enough to take
a minimum pull of 50 N for 2 min. There shall be no
sharp corners or edges to avoid injury and damage to clothing) |
- |
5000 |
|
- |
| 7.7.1(Locks: Top drawer shall be provided with single or dual control key lock having not less than 6 levers or pin cylinder lock having not less than 6 pins, with duplicate keys of stainless steel/nonferrous alloy. Alternatively if required by the purchaser a 3 wheel combination lock or electronic combination lock may be provided either in place of key lock or in addition to key lock) |
- |
5000 |
|
- |
| 7.7.2(Each drawer may also be provided with
individual key lock or pin cylinder lock or combination lock subject to agreement between the purchaser and the supplier.) |
- |
5000 |
|
- |
| 7.8(Locking Mechanism ) |
- |
5000 |
|
- |
| 7.8.1(The locking mechanism shall be such that when
the top drawer is pushed-in fully, it actuates locking
mechanism to lock all other drawers imultaneously,
when they are in pushed-in position) |
- |
5000 |
|
- |
| 7.8.1.1(At the time of locking the cabinet, if one of the
drawers is not fully pushed-in, that drawer shall remain unlocked and can be used. As soon as that drawer is pushed-in fully, it shall get locked automatically without further operation of key by the user.) |
- |
5000 |
|
- |
| 7.8.1.2(In addition to the above, isolation mechanism
shall also be provided to permit independent locking/ use of other drawers. Such isolation mechanism provided on drawers shall be manually operated) |
- |
5000 |
|
- |
| 8(Assemblies) |
- |
5000 |
|
- |
| 8.1(The components shall be assembled by bolting,
welding, riveting or by any combination of these
processes) |
- |
5000 |
|
- |
| 8.2(All joints between outer body and inner boxes,
the drawer front and the outer body shall be such that, there is minimum direct conduction of heat from outer body to inner body) |
- |
5000 |
|
- |
| 9.1(Drawer Suspension Test and Latch Test: The drawer loaded with evenly distributed load of 30 kg
(excluding the weight of drawer) in any drawer shall be operated for 5 000 cycles at a rate of 300 cycles/h ±10 percent. One opening and one closing shall constitute one cycle. The test shall be carried out with maximum two breaks by using electrically or mechanically operated test equipment with a counter fitted on it. After 5 000 cycles the suspension slide and latch mechanism shall not show any apparent distortion, cracks, or failures to operate in a normal smooth manner) |
- |
5000 |
|
- |
| 10.1(Finish: All dents, burrs and sharp edges shall be removed from the various components and they shall be thoroughly degreased and cleaned of rust and scale) |
- |
5000 |
|
- |
| 10.2(The inside and outside surfaces of the fire resisting
(Insulating) filing cabinet shall be painted or powder coated. In case of paint, an appropriate primer and undercoating shall be used in accordance to industry practices. The minimum overall thickness of the coatings shall be 50 μ for powder coating and 70 μ for liquid paint. Cross hatch test shall be conducted to confirm the adhesion of coating in accordance with 10.2.1) |
- |
5000 |
|
- |
| 10.2.1(Cross Hatch Test) |
- |
5000 |
|
- |
| 10.2.1(a) Make 6 parallel cut marks using sharp metal
pointer and straight edge, through the painted/
coated surface, so as to make the base surface
visible through cut marks) |
- |
5000 |
|
- |
| 10.2.1(b) Cut marks shall be minimum 20 mm long and
at 2 mm distance from each other) |
- |
5000 |
|
- |
| 10.2.1(c) Make 6 similar cut marks in the direction
perpendicular to first set of cut marks, with
same length and spacing) |
- |
5000 |
|
- |
| 10.2.1(d) These 12 cut marks together shall make a
pattern of 25 squares of 2 mm × 2mm size,
totally separated from each other) |
- |
5000 |
|
- |
| 10.2.1(f) To ensure continuous contact with paint/coat
film, rub the tape firmly and remove air
bubbles under the tape, if any) |
- |
5000 |
|
- |
| 10.2.1(g)Within 60 to 120 s after sticking the tape,
remove it by seizing free end of the tape and
rapidly pulling it off at an angle close to 180°.) |
- |
5000 |
|
- |
| 10.2.1(h) Painting/Coating quality is considered as
acceptable, if no part of any 2 mm × 2 mm
square of paint/coat comes off the surface due
to pulling the tape) |
- |
5000 |
|
- |
| 11.1(Fire endurance test) |
- |
5000 |
|
- |
| 11.2(Fire and impact test) |
- |
5000 |
|
- |
| 12.1(Marking of Cabinets:A metal plate showing classification of cabinet together with the manufacturer’s name, serial number and the
year of manufacture shall be fixed inside surface of
the top drawer of the cabinet in such a way that it is
visible when it is opened.) |
- |
5000 |
|
- |
| 12.2(Marking on Keys: The keys shall bear an identification number which shall not be the same as the serial number of the cabinet) |
- |
5000 |
|
- |
| 3(Types & Rating) |
- |
5000 |
|
- |
| 3.1(i) The fire resisting filing cabinets shall be of two types:
a) Vertical fire resisting filing cabinet, and
b) Lateral fire resisting filing cabinet.) |
- |
5000 |
|
- |
| 3.2(ii) The standard and lateral fire resisting filing
cabinets shall have one-drawer or two-drawers or three drawers or four-drawers. A typical drawing of the fire resisting filing cabinet is given in Fig. 1.) |
- |
5000 |
|
- |
| 3.3(iii) The fire resisting filing cabinets shall have fire
resisting ratings of 60 min or 120 min or 180 min or
240 min) |
- |
5000 |
|
- |
| 4(Dimensions and Tolerances, mm) |
- |
5000 |
|
- |
| 4.1(Overall Dimensions of Fire Resisting Filing
Cabinets: The internal usable space of the drawers of fire resisting (insulating) filing cabinets shall be as specified in Table 1 or any other size which is mutually agreed to between the purchaser and the supplier.) |
- |
5000 |
|
- |
| 4.1(Internal usuable space of drawer, mm:) |
- |
5000 |
|
- |
| 4.1(i) Height) |
- |
5000 |
|
- |
| 4.1(ii) Width) |
- |
5000 |
|
- |
| 4.1(iii) Depth) |
- |
5000 |
|
- |
| 4.1(iv) Height of the bottom drawer above floor level) |
- |
5000 |
|
- |
| 5(Materials) |
- |
5000 |
|
- |
| 6(Designations: The filing cabinet shall be designated by the commonly used name, type, the fire rating and the number of this Indian Standard.) |
- |
5000 |
|
- |
| 7(Constructions) |
- |
5000 |
|
- |
| 7.1(Outer body and Inner Box: Outer body and inner box shall be fabricated from mild steel or galvanized steel sheets of not less than 0.8 mm and not more than 1.2 mm nominal thickness. The steel shall not have any burrs or dents. If required the outer
body shall be suitably stiffened to avoid bulging) |
- |
5000 |
|
- |
| 7.2(Cabinets Sub-Assembly: The external body and drawer fronts of the fire resisting (insulating) filing cabinet shall be of double wall type with homogeneous insulating material filled in
between. Further the construction of the cabinet shall be such that each drawer slides in an individual inner box. The inner boxes shall have a insulating layer between each other to prevent fire spreading from one drawer to another. The joining of inner box, intermediate piece and outer body shall be such that, it forms a cavity to receive drawer front ) |
- |
5000 |
|
- |
| 7.3(Filing Drawer: The drawer shall be made from mild steel or galvanized steel sheet of not less than 0.6 mm and not more than 1.0 mm nominal thickness and shall have an arrangement on the sides suitable for the drawer suspension system and an arrangement to stop it when fully pushed in.) |
- |
5000 |
|
- |
| 7.3.1(Drawer Front: The drawer front shall be made from mild steel or galvanized steel sheet of not less than 0.6 mm and not more than 1.0 mm nominal thickness and shall be firmly secured to the drawer body by welding, screwing or riveting or any combination of these processes. The construction of drawer front shall be such that it snugly fits in the cavity provided for the same ) |
- |
5000 |
|
- |
| 7.4.1(Latch: Each drawer of the cabinet shall be removable but shall be fitted with a latch/positive stop to prevent inadvertent withdrawal and rebound. Such latch shall be lifted/unlocked by the pull of the handle or any other mechanism.) |
- |
5000 |
|
- |
| 7.4.2(The locking mechanism shall be designed in such
a manner so that there is minimum passage for direct
conduction of heat from outside to inside) |
- |
5000 |
|
- |
| 7.5(Drawer Suspension The drawer suspension shall be either of the following types to ensure withdrawal of the full depth of the drawer:
a) Ball bearing / Roller bearing suspension
(Movement),
b) Solid roller suspension, and
c) Telescopic slide suspension (Extension) |
- |
5000 |
|
- |
| 7.6(Handles: Each drawer shall be provided either with a handle made from ferrous/non-ferrous material suitably coated for corrosion resistance, or any polymer and fixed to the front of the drawer or with a built in pulling mechanism) |
- |
5000 |
|
- |
| 7.6.1(The drawer handle shall be strong enough to take
a minimum pull of 50 N for 2 min. There shall be no
sharp corners or edges to avoid injury and damage to clothing) |
- |
5000 |
|
- |
| 7.7.1(Locks: Top drawer shall be provided with single or dual control key lock having not less than 6 levers or pin cylinder lock having not less than 6 pins, with duplicate keys of stainless steel/nonferrous alloy. Alternatively if required by the purchaser a 3 wheel combination lock or electronic combination lock may be provided either in place of key lock or in addition to key lock) |
- |
5000 |
|
- |
| 7.7.2(Each drawer may also be provided with
individual key lock or pin cylinder lock or combination lock subject to agreement between the purchaser and the supplier.) |
- |
5000 |
|
- |
| 7.8(Locking Mechanism ) |
- |
5000 |
|
- |
| 7.8.1(The locking mechanism shall be such that when
the top drawer is pushed-in fully, it actuates locking
mechanism to lock all other drawers imultaneously,
when they are in pushed-in position) |
- |
5000 |
|
- |
| 7.8.1.1(At the time of locking the cabinet, if one of the
drawers is not fully pushed-in, that drawer shall remain unlocked and can be used. As soon as that drawer is pushed-in fully, it shall get locked automatically without further operation of key by the user.) |
- |
5000 |
|
- |
| 7.8.1.2(In addition to the above, isolation mechanism
shall also be provided to permit independent locking/ use of other drawers. Such isolation mechanism provided on drawers shall be manually operated) |
- |
5000 |
|
- |
| 8(Assemblies) |
- |
5000 |
|
- |
| 8.1(The components shall be assembled by bolting,
welding, riveting or by any combination of these
processes) |
- |
5000 |
|
- |
| 8.2(All joints between outer body and inner boxes,
the drawer front and the outer body shall be such that, there is minimum direct conduction of heat from outer body to inner body) |
- |
5000 |
|
- |
| 9.1(Drawer Suspension Test and Latch Test: The drawer loaded with evenly distributed load of 30 kg
(excluding the weight of drawer) in any drawer shall be operated for 5 000 cycles at a rate of 300 cycles/h ±10 percent. One opening and one closing shall constitute one cycle. The test shall be carried out with maximum two breaks by using electrically or mechanically operated test equipment with a counter fitted on it. After 5 000 cycles the suspension slide and latch mechanism shall not show any apparent distortion, cracks, or failures to operate in a normal smooth manner) |
- |
5000 |
|
- |
| 10.1(Finish: All dents, burrs and sharp edges shall be removed from the various components and they shall be thoroughly degreased and cleaned of rust and scale) |
- |
5000 |
|
- |
| 10.2(The inside and outside surfaces of the fire resisting
(Insulating) filing cabinet shall be painted or powder coated. In case of paint, an appropriate primer and undercoating shall be used in accordance to industry practices. The minimum overall thickness of the coatings shall be 50 μ for powder coating and 70 μ for liquid paint. Cross hatch test shall be conducted to confirm the adhesion of coating in accordance with 10.2.1) |
- |
5000 |
|
- |
| 10.2.1(Cross Hatch Test) |
- |
5000 |
|
- |
| 10.2.1(a) Make 6 parallel cut marks using sharp metal
pointer and straight edge, through the painted/
coated surface, so as to make the base surface
visible through cut marks) |
- |
5000 |
|
- |
| 10.2.1(b) Cut marks shall be minimum 20 mm long and
at 2 mm distance from each other) |
- |
5000 |
|
- |
| 10.2.1(c) Make 6 similar cut marks in the direction
perpendicular to first set of cut marks, with
same length and spacing) |
- |
5000 |
|
- |
| 10.2.1(d) These 12 cut marks together shall make a
pattern of 25 squares of 2 mm × 2mm size,
totally separated from each other) |
- |
5000 |
|
- |
| 10.2.1(f) To ensure continuous contact with paint/coat
film, rub the tape firmly and remove air
bubbles under the tape, if any) |
- |
5000 |
|
- |
| 10.2.1(g)Within 60 to 120 s after sticking the tape,
remove it by seizing free end of the tape and
rapidly pulling it off at an angle close to 180°.) |
- |
5000 |
|
- |
| 10.2.1(h) Painting/Coating quality is considered as
acceptable, if no part of any 2 mm × 2 mm
square of paint/coat comes off the surface due
to pulling the tape) |
- |
5000 |
|
- |
| 11.1(Fire endurance test) |
- |
150000 |
|
- |
| 11.2(Fire and impact test) |
- |
150000 |
|
- |
| 12.1(Marking of Cabinets:A metal plate showing classification of cabinet together with the manufacturer’s name, serial number and the
year of manufacture shall be fixed inside surface of
the top drawer of the cabinet in such a way that it is
visible when it is opened.) |
- |
15000 |
|
- |
| 12.2(Marking on Keys: The keys shall bear an identification number which shall not be the same as the serial number of the cabinet) |
- |
15000 |
|
- |
| 3(Types & Rating) |
- |
15000 |
|
- |
| 3.1(i) The fire resisting filing cabinets shall be of two types:
a) Vertical fire resisting filing cabinet, and
b) Lateral fire resisting filing cabinet.) |
- |
15000 |
|
- |
| 3.2(ii) The standard and lateral fire resisting filing
cabinets shall have one-drawer or two-drawers or three drawers or four-drawers. A typical drawing of the fire resisting filing cabinet is given in Fig. 1.) |
- |
15000 |
|
- |
| 3.3(iii) The fire resisting filing cabinets shall have fire
resisting ratings of 60 min or 120 min or 180 min or
240 min) |
- |
15000 |
|
- |
| 4(Dimensions and Tolerances, mm) |
- |
15000 |
|
- |
| 4.1(Overall Dimensions of Fire Resisting Filing
Cabinets: The internal usable space of the drawers of fire resisting (insulating) filing cabinets shall be as specified in Table 1 or any other size which is mutually agreed to between the purchaser and the supplier.) |
- |
15000 |
|
- |
| 4.1(Internal usuable space of drawer, mm:) |
- |
15000 |
|
- |
| 4.1(i) Height) |
- |
15000 |
|
- |
| 4.1(ii) Width) |
- |
15000 |
|
- |
| 4.1(iii) Depth) |
- |
15000 |
|
- |
| 4.1(iv) Height of the bottom drawer above floor level) |
- |
15000 |
|
- |
| 5(Materials) |
- |
15000 |
|
- |
| 6(Designations: The filing cabinet shall be designated by the commonly used name, type, the fire rating and the number of this Indian Standard.) |
- |
15000 |
|
- |
| 7(Constructions) |
- |
15000 |
|
- |
| 7.1(Outer body and Inner Box: Outer body and inner box shall be fabricated from mild steel or galvanized steel sheets of not less than 0.8 mm and not more than 1.2 mm nominal thickness. The steel shall not have any burrs or dents. If required the outer
body shall be suitably stiffened to avoid bulging) |
- |
15000 |
|
- |
| 7.2(Cabinets Sub-Assembly: The external body and drawer fronts of the fire resisting (insulating) filing cabinet shall be of double wall type with homogeneous insulating material filled in
between. Further the construction of the cabinet shall be such that each drawer slides in an individual inner box. The inner boxes shall have a insulating layer between each other to prevent fire spreading from one drawer to another. The joining of inner box, intermediate piece and outer body shall be such that, it forms a cavity to receive drawer front ) |
- |
15000 |
|
- |
| 7.3(Filing Drawer: The drawer shall be made from mild steel or galvanized steel sheet of not less than 0.6 mm and not more than 1.0 mm nominal thickness and shall have an arrangement on the sides suitable for the drawer suspension system and an arrangement to stop it when fully pushed in.) |
- |
15000 |
|
- |
| 7.3.1(Drawer Front: The drawer front shall be made from mild steel or galvanized steel sheet of not less than 0.6 mm and not more than 1.0 mm nominal thickness and shall be firmly secured to the drawer body by welding, screwing or riveting or any combination of these processes. The construction of drawer front shall be such that it snugly fits in the cavity provided for the same ) |
- |
15000 |
|
- |
| 7.4.1(Latch: Each drawer of the cabinet shall be removable but shall be fitted with a latch/positive stop to prevent inadvertent withdrawal and rebound. Such latch shall be lifted/unlocked by the pull of the handle or any other mechanism.) |
- |
15000 |
|
- |
| 7.4.2(The locking mechanism shall be designed in such
a manner so that there is minimum passage for direct
conduction of heat from outside to inside) |
- |
15000 |
|
- |
| 7.5(Drawer Suspension The drawer suspension shall be either of the following types to ensure withdrawal of the full depth of the drawer:
a) Ball bearing / Roller bearing suspension
(Movement),
b) Solid roller suspension, and
c) Telescopic slide suspension (Extension) |
- |
15000 |
|
- |
| 7.6(Handles: Each drawer shall be provided either with a handle made from ferrous/non-ferrous material suitably coated for corrosion resistance, or any polymer and fixed to the front of the drawer or with a built in pulling mechanism) |
- |
15000 |
|
- |
| 7.6.1(The drawer handle shall be strong enough to take
a minimum pull of 50 N for 2 min. There shall be no
sharp corners or edges to avoid injury and damage to clothing) |
- |
15000 |
|
- |
| 7.7.1(Locks: Top drawer shall be provided with single or dual control key lock having not less than 6 levers or pin cylinder lock having not less than 6 pins, with duplicate keys of stainless steel/nonferrous alloy. Alternatively if required by the purchaser a 3 wheel combination lock or electronic combination lock may be provided either in place of key lock or in addition to key lock) |
- |
15000 |
|
- |
| 7.7.2(Each drawer may also be provided with
individual key lock or pin cylinder lock or combination lock subject to agreement between the purchaser and the supplier.) |
- |
15000 |
|
- |
| 7.8(Locking Mechanism ) |
- |
15000 |
|
- |
| 7.8.1(The locking mechanism shall be such that when
the top drawer is pushed-in fully, it actuates locking
mechanism to lock all other drawers imultaneously,
when they are in pushed-in position) |
- |
15000 |
|
- |
| 7.8.1.1(At the time of locking the cabinet, if one of the
drawers is not fully pushed-in, that drawer shall remain unlocked and can be used. As soon as that drawer is pushed-in fully, it shall get locked automatically without further operation of key by the user.) |
- |
15000 |
|
- |
| 7.8.1.2(In addition to the above, isolation mechanism
shall also be provided to permit independent locking/ use of other drawers. Such isolation mechanism provided on drawers shall be manually operated) |
- |
15000 |
|
- |
| 8(Assemblies) |
- |
15000 |
|
- |
| 8.1(The components shall be assembled by bolting,
welding, riveting or by any combination of these
processes) |
- |
15000 |
|
- |
| 8.2(All joints between outer body and inner boxes,
the drawer front and the outer body shall be such that, there is minimum direct conduction of heat from outer body to inner body) |
- |
15000 |
|
- |
| 9.1(Drawer Suspension Test and Latch Test: The drawer loaded with evenly distributed load of 30 kg
(excluding the weight of drawer) in any drawer shall be operated for 5 000 cycles at a rate of 300 cycles/h ±10 percent. One opening and one closing shall constitute one cycle. The test shall be carried out with maximum two breaks by using electrically or mechanically operated test equipment with a counter fitted on it. After 5 000 cycles the suspension slide and latch mechanism shall not show any apparent distortion, cracks, or failures to operate in a normal smooth manner) |
- |
15000 |
|
- |
| 10.1(Finish: All dents, burrs and sharp edges shall be removed from the various components and they shall be thoroughly degreased and cleaned of rust and scale) |
- |
15000 |
|
- |
| 10.2(The inside and outside surfaces of the fire resisting
(Insulating) filing cabinet shall be painted or powder coated. In case of paint, an appropriate primer and undercoating shall be used in accordance to industry practices. The minimum overall thickness of the coatings shall be 50 μ for powder coating and 70 μ for liquid paint. Cross hatch test shall be conducted to confirm the adhesion of coating in accordance with 10.2.1) |
- |
15000 |
|
- |
| 10.2.1(Cross Hatch Test) |
- |
15000 |
|
- |
| 10.2.1(a) Make 6 parallel cut marks using sharp metal
pointer and straight edge, through the painted/
coated surface, so as to make the base surface
visible through cut marks) |
- |
15000 |
|
- |
| 10.2.1(b) Cut marks shall be minimum 20 mm long and
at 2 mm distance from each other) |
- |
15000 |
|
- |
| 10.2.1(c) Make 6 similar cut marks in the direction
perpendicular to first set of cut marks, with
same length and spacing) |
- |
15000 |
|
- |
| 10.2.1(d) These 12 cut marks together shall make a
pattern of 25 squares of 2 mm × 2mm size,
totally separated from each other) |
- |
15000 |
|
- |
| 10.2.1(f) To ensure continuous contact with paint/coat
film, rub the tape firmly and remove air
bubbles under the tape, if any) |
- |
15000 |
|
- |
| 10.2.1(g)Within 60 to 120 s after sticking the tape,
remove it by seizing free end of the tape and
rapidly pulling it off at an angle close to 180°.) |
- |
15000 |
|
- |
| 10.2.1(h) Painting/Coating quality is considered as
acceptable, if no part of any 2 mm × 2 mm
square of paint/coat comes off the surface due
to pulling the tape) |
- |
15000 |
|
- |
| 11.1(Fire endurance test) |
- |
15000 |
|
- |
| 11.2(Fire and impact test) |
- |
15000 |
|
- |
| 12.1(Marking of Cabinets:A metal plate showing classification of cabinet together with the manufacturer’s name, serial number and the
year of manufacture shall be fixed inside surface of
the top drawer of the cabinet in such a way that it is
visible when it is opened.) |
- |
15000 |
|
- |
| 12.2(Marking on Keys: The keys shall bear an identification number which shall not be the same as the serial number of the cabinet) |
- |
15000 |
|
- |
| 3(Types & Rating) |
- |
15000 |
|
- |
| 3.1(i) The fire resisting filing cabinets shall be of two types:
a) Vertical fire resisting filing cabinet, and
b) Lateral fire resisting filing cabinet.) |
- |
15000 |
|
- |
| 3.2(ii) The standard and lateral fire resisting filing
cabinets shall have one-drawer or two-drawers or three drawers or four-drawers. A typical drawing of the fire resisting filing cabinet is given in Fig. 1.) |
- |
15000 |
|
- |
| 3.3(iii) The fire resisting filing cabinets shall have fire
resisting ratings of 60 min or 120 min or 180 min or
240 min) |
- |
15000 |
|
- |
| 4(Dimensions and Tolerances, mm) |
- |
15000 |
|
- |
| 4.1(Overall Dimensions of Fire Resisting Filing
Cabinets: The internal usable space of the drawers of fire resisting (insulating) filing cabinets shall be as specified in Table 1 or any other size which is mutually agreed to between the purchaser and the supplier.) |
- |
15000 |
|
- |
| 4.1(Internal usuable space of drawer, mm:) |
- |
15000 |
|
- |
| 4.1(i) Height) |
- |
15000 |
|
- |
| 4.1(ii) Width) |
- |
15000 |
|
- |
| 4.1(iii) Depth) |
- |
15000 |
|
- |
| 4.1(iv) Height of the bottom drawer above floor level) |
- |
15000 |
|
- |
| 5(Materials) |
- |
15000 |
|
- |
| 6(Designations: The filing cabinet shall be designated by the commonly used name, type, the fire rating and the number of this Indian Standard.) |
- |
15000 |
|
- |
| 7(Constructions) |
- |
15000 |
|
- |
| 7.1(Outer body and Inner Box: Outer body and inner box shall be fabricated from mild steel or galvanized steel sheets of not less than 0.8 mm and not more than 1.2 mm nominal thickness. The steel shall not have any burrs or dents. If required the outer
body shall be suitably stiffened to avoid bulging) |
- |
15000 |
|
- |
| 7.2(Cabinets Sub-Assembly: The external body and drawer fronts of the fire resisting (insulating) filing cabinet shall be of double wall type with homogeneous insulating material filled in
between. Further the construction of the cabinet shall be such that each drawer slides in an individual inner box. The inner boxes shall have a insulating layer between each other to prevent fire spreading from one drawer to another. The joining of inner box, intermediate piece and outer body shall be such that, it forms a cavity to receive drawer front ) |
- |
15000 |
|
- |
| 7.3(Filing Drawer: The drawer shall be made from mild steel or galvanized steel sheet of not less than 0.6 mm and not more than 1.0 mm nominal thickness and shall have an arrangement on the sides suitable for the drawer suspension system and an arrangement to stop it when fully pushed in.) |
- |
15000 |
|
- |
| 7.3.1(Drawer Front: The drawer front shall be made from mild steel or galvanized steel sheet of not less than 0.6 mm and not more than 1.0 mm nominal thickness and shall be firmly secured to the drawer body by welding, screwing or riveting or any combination of these processes. The construction of drawer front shall be such that it snugly fits in the cavity provided for the same ) |
- |
15000 |
|
- |
| 7.4.1(Latch: Each drawer of the cabinet shall be removable but shall be fitted with a latch/positive stop to prevent inadvertent withdrawal and rebound. Such latch shall be lifted/unlocked by the pull of the handle or any other mechanism.) |
- |
15000 |
|
- |
| 7.4.2(The locking mechanism shall be designed in such
a manner so that there is minimum passage for direct
conduction of heat from outside to inside) |
- |
15000 |
|
- |
| 7.5(Drawer Suspension The drawer suspension shall be either of the following types to ensure withdrawal of the full depth of the drawer:
a) Ball bearing / Roller bearing suspension
(Movement),
b) Solid roller suspension, and
c) Telescopic slide suspension (Extension) |
- |
15000 |
|
- |
| 7.6(Handles: Each drawer shall be provided either with a handle made from ferrous/non-ferrous material suitably coated for corrosion resistance, or any polymer and fixed to the front of the drawer or with a built in pulling mechanism) |
- |
15000 |
|
- |
| 7.6.1(The drawer handle shall be strong enough to take
a minimum pull of 50 N for 2 min. There shall be no
sharp corners or edges to avoid injury and damage to clothing) |
- |
15000 |
|
- |
| 7.7.1(Locks: Top drawer shall be provided with single or dual control key lock having not less than 6 levers or pin cylinder lock having not less than 6 pins, with duplicate keys of stainless steel/nonferrous alloy. Alternatively if required by the purchaser a 3 wheel combination lock or electronic combination lock may be provided either in place of key lock or in addition to key lock) |
- |
15000 |
|
- |
| 7.7.2(Each drawer may also be provided with
individual key lock or pin cylinder lock or combination lock subject to agreement between the purchaser and the supplier.) |
- |
15000 |
|
- |
| 7.8(Locking Mechanism ) |
- |
15000 |
|
- |
| 7.8.1(The locking mechanism shall be such that when
the top drawer is pushed-in fully, it actuates locking
mechanism to lock all other drawers imultaneously,
when they are in pushed-in position) |
- |
15000 |
|
- |
| 7.8.1.1(At the time of locking the cabinet, if one of the
drawers is not fully pushed-in, that drawer shall remain unlocked and can be used. As soon as that drawer is pushed-in fully, it shall get locked automatically without further operation of key by the user.) |
- |
15000 |
|
- |
| 7.8.1.2(In addition to the above, isolation mechanism
shall also be provided to permit independent locking/ use of other drawers. Such isolation mechanism provided on drawers shall be manually operated) |
- |
15000 |
|
- |
| 8(Assemblies) |
- |
15000 |
|
- |
| 8.1(The components shall be assembled by bolting,
welding, riveting or by any combination of these
processes) |
- |
15000 |
|
- |
| 8.2(All joints between outer body and inner boxes,
the drawer front and the outer body shall be such that, there is minimum direct conduction of heat from outer body to inner body) |
- |
15000 |
|
- |
| 9.1(Drawer Suspension Test and Latch Test: The drawer loaded with evenly distributed load of 30 kg
(excluding the weight of drawer) in any drawer shall be operated for 5 000 cycles at a rate of 300 cycles/h ±10 percent. One opening and one closing shall constitute one cycle. The test shall be carried out with maximum two breaks by using electrically or mechanically operated test equipment with a counter fitted on it. After 5 000 cycles the suspension slide and latch mechanism shall not show any apparent distortion, cracks, or failures to operate in a normal smooth manner) |
- |
15000 |
|
- |
| 10.1(Finish: All dents, burrs and sharp edges shall be removed from the various components and they shall be thoroughly degreased and cleaned of rust and scale) |
- |
15000 |
|
- |
| 10.2(The inside and outside surfaces of the fire resisting
(Insulating) filing cabinet shall be painted or powder coated. In case of paint, an appropriate primer and undercoating shall be used in accordance to industry practices. The minimum overall thickness of the coatings shall be 50 μ for powder coating and 70 μ for liquid paint. Cross hatch test shall be conducted to confirm the adhesion of coating in accordance with 10.2.1) |
- |
15000 |
|
- |
| 10.2.1(Cross Hatch Test) |
- |
15000 |
|
- |
| 10.2.1(a) Make 6 parallel cut marks using sharp metal
pointer and straight edge, through the painted/
coated surface, so as to make the base surface
visible through cut marks) |
- |
15000 |
|
- |
| 10.2.1(b) Cut marks shall be minimum 20 mm long and
at 2 mm distance from each other) |
- |
15000 |
|
- |
| 10.2.1(c) Make 6 similar cut marks in the direction
perpendicular to first set of cut marks, with
same length and spacing) |
- |
15000 |
|
- |
| 10.2.1(d) These 12 cut marks together shall make a
pattern of 25 squares of 2 mm × 2mm size,
totally separated from each other) |
- |
15000 |
|
- |
| 10.2.1(f) To ensure continuous contact with paint/coat
film, rub the tape firmly and remove air
bubbles under the tape, if any) |
- |
15000 |
|
- |
| 10.2.1(g)Within 60 to 120 s after sticking the tape,
remove it by seizing free end of the tape and
rapidly pulling it off at an angle close to 180°.) |
- |
15000 |
|
- |
| 10.2.1(h) Painting/Coating quality is considered as
acceptable, if no part of any 2 mm × 2 mm
square of paint/coat comes off the surface due
to pulling the tape) |
- |
15000 |
|
- |
| 11.1(Fire endurance test) |
- |
150000 |
|
- |
| 11.2(Fire and impact test) |
- |
150000 |
|
- |
| 12.1(Marking of Cabinets:A metal plate showing classification of cabinet together with the manufacturer’s name, serial number and the
year of manufacture shall be fixed inside surface of
the top drawer of the cabinet in such a way that it is
visible when it is opened.) |
- |
5000 |
|
- |
| 12.2(Marking on Keys: The keys shall bear an identification number which shall not be the same as the serial number of the cabinet) |
- |
5000 |
|
- |
|
14 Nov, 2027 |
- Included w.e.f. 28.03.2025 |
| 4504 |
URS PRODUCTS AND TESTING PVT. LTD. (A29), NOIDA
| 8168906
| IS 21 (1992) |
Wrought aluminium and aluminium alloys for manufacture of utensils specification (Fourth Revision) |
- |
15000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4.1, & 4.1.1(Lead) |
- |
1500 |
|
- |
| 4.1.2(Aluminium) |
- |
800 |
|
- |
| 4.2,
Table 1of IS:21 (Designation 64430)(Aluminium) |
- |
800 |
|
- |
| 4.2,
Table 1of IS:21 (Designation 64430)(Lead) |
- |
800 |
|
- |
| 4.2,
Table 1of IS:21 (Designation 64430)(Chromium) |
- |
800 |
|
- |
| 4.2,
Table 1of IS:21 (Designation 64430)(Titanium and or other grain refining elements) |
- |
800 |
|
- |
| 4.2,
Table 1of IS:21 (Designation 64430)(Zinc) |
- |
800 |
|
- |
| 4.2,
Table 1of IS:21 (Designation 64430)(Manganese) |
- |
800 |
|
- |
| 4.2,
Table 1of IS:21 (Designation 64430)(Iron) |
- |
800 |
|
- |
| 4.2,
Table 1of IS:21 (Designation 40800)(Silicon) |
- |
800 |
|
- |
| 4.2,
Table 1of IS:21 (Designation 64430)(Magnesium) |
- |
800 |
|
- |
| 4.2,
Table 1of IS:21 (Designation 64430)(Copper) |
- |
800 |
|
- |
| 4.2,
Table 1of IS:21 (Designation 51000-B)(Aluminium) |
- |
800 |
|
- |
| 4.2,
Table 1of IS:21 (Designation 51000-B)(Lead) |
- |
800 |
|
- |
| 4.2,
Table 1of IS:21 (Designation 51000-B)(Chromium) |
- |
800 |
|
- |
| 4.2,
Table 1of IS:21 (Designation 51000-B)(Zinc) |
- |
800 |
|
- |
| 4.2,
Table 1of IS:21 (Designation 51000-B)(Manganese) |
- |
800 |
|
- |
| 4.2,
Table 1of IS:21 (Designation 51000-B)(Iron) |
- |
800 |
|
- |
| 4.2,
Table 1of IS:21 (Designation 51000-B)(Silicon) |
- |
800 |
|
- |
| 4.2,
Table 1of IS:21 (Designation 51000-B)(Magnesium) |
- |
800 |
|
- |
| 4.2,
Table 1of IS:21 (Designation 51000-B)(Copper) |
- |
800 |
|
- |
| 4.2,
Table 1of IS:21 (Designation 51000-A)(Aluminium) |
- |
800 |
|
- |
| 4.2,
Table 1of IS:21 (Designation 51000-A)(Lead) |
- |
800 |
|
- |
| 4.2,
Table 1of IS:21 (Designation 51000-A)(Chromium) |
- |
800 |
|
- |
| 4.2,
Table 1of IS:21 (Designation 51000-A)(Zinc) |
- |
800 |
|
- |
| 4.2,
Table 1of IS:21 (Designation 51000-A)(Manganese) |
- |
800 |
|
- |
| 4.2,
Table 1of IS:21 (Designation 51000-A)(Iron) |
- |
800 |
|
- |
| 4.2,
Table 1of IS:21 (Designation 51000-A)(Silicon) |
- |
800 |
|
- |
| 4.2,
Table 1of IS:21 (Designation 51000-A)(Magnesium) |
- |
800 |
|
- |
| 4.2,
Table 1of IS:21 (Designation 51000-A)(Copper) |
- |
800 |
|
- |
| 4.2,
Table 1of IS:21 (Designation 40800)(Aluminium) |
- |
800 |
|
- |
| 4.2,
Table 1of IS:21 (Designation 40800)(Lead) |
- |
800 |
|
- |
| 4.2,
Table 1of IS:21 (Designation 40800)(Titanium and or other grain refining elements) |
- |
800 |
|
- |
| 4.2,
Table 1of IS:21 (Designation 40800)(Zinc) |
- |
800 |
|
- |
| 4.2,
Table 1of IS:21 (Designation 40800)(Manganese) |
- |
800 |
|
- |
| 4.2,
Table 1of IS:21 (Designation 40800)(Iron) |
- |
800 |
|
- |
| 4.2,
Table 1of IS:21 (Designation 40800)(Magnesium) |
- |
800 |
|
- |
| 4.2,
Table 1of IS:21 (Designation 40800)(Copper) |
- |
800 |
|
- |
| 4.2,
Table 1of IS:21 (Designation 31500)(Aluminium) |
- |
800 |
|
- |
| 4.2,
Table 1of IS:21 (Designation 31500)(Titanium and or other grain refining elements) |
- |
800 |
|
- |
| 4.2,
Table 1of IS:21 (Designation 31500)(Lead) |
- |
800 |
|
- |
| 4.2,
Table 1of IS:21 (Designation 31500)(Zinc) |
- |
800 |
|
- |
| 4.2,
Table 1of IS:21 (Designation 31500)(Manganese) |
- |
800 |
|
- |
| 4.2,
Table 1of IS:21 (Designation 31500)(Iron) |
- |
800 |
|
- |
| 4.2,
Table 1of IS:21 (Designation 31500)(Silicon) |
- |
800 |
|
- |
| 4.2,
Table 1of IS:21 (Designation 31500)(Magnesium) |
- |
800 |
|
- |
| 4.2,
Table 1of IS:21 (Designation 31500)(Copper) |
- |
800 |
|
- |
| 4.2,
Table 1of IS:21 (Designation 31000)(Aluminium) |
- |
800 |
|
- |
| 4.2,
Table 1of IS:21 (Designation 31000)(Lead) |
- |
800 |
|
- |
| 4.2,
Table 1of IS:21 (Designation 31000)(Chromium) |
- |
800 |
|
- |
| 4.2,
Table 1of IS:21 (Designation 31000)(Titanium and or other grain refining elements) |
- |
800 |
|
- |
| 4.2,
Table 1of IS:21 (Designation 31000)(Zinc) |
- |
800 |
|
- |
| 4.2,
Table 1of IS:21 (Designation 31000)(Manganese) |
- |
800 |
|
- |
| 4.2,
Table 1of IS:21 (Designation 31000)(Iron) |
- |
800 |
|
- |
| 4.2,
Table 1of IS:21 (Designation 31000)(Silicon) |
- |
800 |
|
- |
| 4.2,
Table 1of IS:21 (Designation 31000)(Magnesium) |
- |
800 |
|
- |
| 4.2,
Table 1of IS:21 (Designation 31000)(Copper) |
- |
800 |
|
- |
| 4.2,
Table 1of IS:21 (Designation 19600)(Aluminium) |
- |
800 |
|
- |
| 4.2,
Table 1of IS:21 (Designation 19600)(Cu+Si+Fe+Mn+Zn) |
- |
800 |
|
- |
| 4.2,
Table 1of IS:21 (Designation 19500)(Aluminium) |
- |
800 |
|
- |
| 4.2,
Table 1of IS:21 (Designation 19500)(Cu+Si+Fe+Mn+Zn) |
- |
800 |
|
- |
| 4.2,
Table 1of IS:21 (Designation 19000)(Cu+Mg+Si+Fe+Mn+Zn) |
- |
800 |
|
- |
| 4.2,
Table 1of IS:21 (Designation 19000)(Aluminium) |
- |
800 |
|
- |
| 4.2,
Table 1of IS:21 (Designation 19600)(Lead) |
- |
800 |
|
- |
| 4.2,
Table 1of IS:21 (Designation 19500)(Lead) |
- |
800 |
|
- |
| 4.2,
Table 1of IS:21 (Designation 19000)(Lead) |
- |
800 |
|
- |
| 4.2,
Table 1of IS:21 (Designation 19600)(Zinc) |
- |
800 |
|
- |
| 4.2,
Table 1of IS:21 (Designation 19500)(Zinc) |
- |
800 |
|
- |
| 4.2,
Table 1of IS:21 (Designation 19000)(Zinc) |
- |
800 |
|
- |
| 4.2,
Table 1of IS:21 (Designation 19600)(Manganese) |
- |
800 |
|
- |
| 4.2,
Table 1of IS:21 (Designation 19500)(Manganese) |
- |
800 |
|
- |
| 4.2,
Table 1of IS:21 (Designation 19000)(Manganese) |
- |
800 |
|
- |
| 4.2,
Table 1of IS:21 (Designation 19600)(Iron) |
- |
800 |
|
- |
| 4.2,
Table 1of IS:21 (Designation 19500)(Iron) |
- |
800 |
|
- |
| 4.2,
Table 1of IS:21 (Designation 19000)(Iron) |
- |
800 |
|
- |
| 4.2,
Table 1of IS:21 (Designation 19600)(Silicon) |
- |
800 |
|
- |
| 4.2,
Table 1of IS:21 (Designation 19500)(Silicon) |
- |
800 |
|
- |
| 4.2,
Table 1of IS:21 (Designation 19000)(Silicon) |
- |
800 |
|
- |
| 4.2,
Table 1of IS:21 (Designation 19600)(Copper) |
- |
800 |
|
- |
| 4.2,
Table 1of IS:21 (Designation 19500)(Copper) |
- |
800 |
|
- |
| 4.2,
Table 1of IS:21 (Designation 19000)(Copper) |
- |
800 |
|
- |
| 4.2,
Table 1of IS:21 (Designation 19000)(Magnesium) |
- |
800 |
|
- |
| 4.2,
Table 2 of IS:21 (Designation & Condition 64430, WP')(Tensile Strength) |
- |
2000 |
|
- |
| 4.2,
Table 2 of IS:21 (Designation & Condition 64430, 'W')(Tensile Strength) |
- |
2000 |
|
- |
| 4.2,
Table 2 of IS:21 (Designation & Condition 64430, 'O')(Tensile Strength) |
- |
2000 |
|
- |
| 4.2,
Table 2 of IS:21 (Designation & Condition 51000-B, 'H4')(Tensile Strength) |
- |
2000 |
|
- |
| 4.2,
Table 2 of IS:21 (Designation & Condition 51000-B, 'H3')(Tensile Strength) |
- |
2000 |
|
- |
| 4.2,
Table 2 of IS:21 (Designation & Condition 51000-B, 'H2')(Tensile Strength) |
- |
2000 |
|
- |
| 4.2,
Table 2 of IS:21 (Designation & Condition 51000-B, 'H1')(Tensile Strength) |
- |
2000 |
|
- |
| 4.2,
Table 2 of IS:21 (Designation & Condition 51000-A, 'H3')(Tensile Strength) |
- |
2000 |
|
- |
| 4.2,
Table 2 of IS:21 (Designation & Condition 51000-A, 'H2')(Tensile Strength) |
- |
2000 |
|
- |
| 4.2,
Table 2 of IS:21 (Designation & Condition 51000-A, 'H1')(Tensile Strength) |
- |
2000 |
|
- |
| 4.2,
Table 2 of IS:21 (Designation & Condition 51000-A, 'O')(Tensile Strength) |
- |
2000 |
|
- |
| 4.2,
Table 2 of IS:21 (Designation & Condition 40800, 'H4')(Tensile Strength) |
- |
2000 |
|
- |
| 4.2,
Table 2 of IS:21 (Designation & Condition 40800, 'H3')(Tensile Strength) |
- |
2000 |
|
- |
| 4.2,
Table 2 of IS:21 (Designation & Condition 40800, 'H2')(Tensile Strength) |
- |
2000 |
|
- |
| 4.2,
Table 2 of IS:21 (Designation & Condition 40800, 'H1')(Tensile Strength) |
- |
2000 |
|
- |
| 4.2,
Table 2 of IS:21 (Designation & Condition 40800, 'O')(Tensile Strength) |
- |
2000 |
|
- |
| 4.2,
Table 2 of IS:21 (Designation & Condition 31500, 'H4')(Tensile Strength) |
- |
2000 |
|
- |
| 4.2,
Table 2 of IS:21 (Designation & Condition 31500, 'H3')(Tensile Strength) |
- |
2000 |
|
- |
| 4.2,
Table 2 of IS:21 (Designation & Condition 31500, 'H2')(Tensile Strength) |
- |
2000 |
|
- |
| 4.2,
Table 2 of IS:21 (Designation & Condition 31500, 'H1')(Tensile Strength) |
- |
2000 |
|
- |
| 4.2,
Table 2 of IS:21 (Designation & Condition 31500, 'O')(Tensile Strength) |
- |
2000 |
|
- |
| 4.2,
Table 2 of IS:21 (Designation & Condition 31000, 'H4')(Tensile Strength) |
- |
2000 |
|
- |
| 4.2,
Table 2 of IS:21 (Designation & Condition 31000, 'H3')(Tensile Strength) |
- |
2000 |
|
- |
| 4.2,
Table 2 of IS:21 (Designation & Condition 31000, 'H2')(Tensile Strength) |
- |
2000 |
|
- |
| 4.2,
Table 2 of IS:21 (Designation & Condition 31000, 'H1')(Tensile Strength) |
- |
2000 |
|
- |
| 4.2,
Table 2 of IS:21 (Designation & Condition 31000, 'O')(Tensile Strength) |
- |
2000 |
|
- |
| 4.2,
Table 2 of IS:21 (Designation & Condition 19600, 'H4')(Tensile Strength) |
- |
2000 |
|
- |
| 4.2,
Table 2 of IS:21 (Designation & Condition 19600, 'H2')(Tensile Strength) |
- |
2000 |
|
- |
| 4.2,
Table 2 of IS:21 (Designation & Condition 19600, 'O')(Tensile Strength) |
- |
2000 |
|
- |
| 4.2,
Table 2 of IS:21 (Designation & Condition 19500, 'H4')(Tensile Strength) |
- |
2000 |
|
- |
| 4.2,
Table 2 of IS:21 (Designation & Condition 19500, 'H2')(Tensile Strength) |
- |
2000 |
|
- |
| 4.2,
Table 2 of IS:21 (Designation & Condition 19500, 'O')(Tensile Strength) |
- |
2000 |
|
- |
| 4.2,
Table 2 of IS:21 (Designation & Condition 19000, 'H4')(Tensile Strength) |
- |
2000 |
|
- |
| 4.2,
Table 2 of IS:21 (Designation & Condition 19000, 'H3')(Tensile Strength) |
- |
2000 |
|
- |
| 4.2,
Table 2 of IS:21 (Designation & Condition 19000, 'H2')(Tensile Strength) |
- |
2000 |
|
- |
| 4.2,
Table 2 of IS:21 (Designation & Condition 19000, 'H1')(Tensile Strength) |
- |
2000 |
|
- |
| 4.2,
Table 2 of IS:21 (Designation & Condition 19000, 'O')(Tensile Strength) |
- |
2000 |
|
- |
| 4.2,
Table 2 of IS:21 (Designation & Condition 64430, WP')(0.2 Percent Proof Stress) |
- |
2000 |
|
- |
| 4.2,
Table 2 of IS:21 (Designation & Condition 64430, 'W')(0.2 Percent Proof Stress) |
- |
2000 |
|
- |
| 4.2,
Table 2 of IS:21 (Designation & Condition 51000-B, 'H3')(0.2 Percent Proof Stress) |
- |
2000 |
|
- |
| 4.2,
Table 2 of IS:21 (Designation & Condition 51000-B, 'H2')(0.2 Percent Proof Stress) |
- |
2000 |
|
- |
| 4.2,
Table 2 of IS:21 (Designation & Condition 51000-B, 'H1')(0.2 Percent Proof Stress) |
- |
2000 |
|
- |
| 4.2,
Table 2 of IS:21 (Designation & Condition 51000-A, 'H3')(0.2 Percent Proof Stress) |
- |
2000 |
|
- |
| 4.2,
Table 2 of IS:21 (Designation & Condition 51000-A, 'H2')(0.2 Percent Proof Stress) |
- |
2000 |
|
- |
| 4.2,
Table 2 of IS:21 (Designation & Condition 51000-A, 'H1')(0.2 Percent Proof Stress) |
- |
2000 |
|
- |
| 4.2,
Table 2 of IS:21 (Designation & Condition 64430, WP')(Elongation on 50 mm gauge length (For thickness over 2.6 to 6.3 mm)) |
- |
2000 |
|
- |
| 4.2,
Table 2 of IS:21 (Designation & Condition 64430, 'W')(Elongation on 50 mm gauge length (For thickness over 2.6 to 6.3 mm)) |
- |
2000 |
|
- |
| 4.2,
Table 2 of IS:21 (Designation & Condition 64430, 'O')(Elongation on 50 mm gauge length (For thickness over 2.6 to 6.3 mm)) |
- |
2000 |
|
- |
| 4.2,
Table 2 of IS:21 (Designation & Condition 51000-B, 'H4')(Elongation on 50 mm gauge length (For thickness over 2.6 to 6.3 mm)) |
- |
2000 |
|
- |
| 4.2,
Table 2 of IS:21 (Designation & Condition 51000-B, 'H3')(Elongation on 50 mm gauge length (For thickness over 2.6 to 6.3 mm)) |
- |
2000 |
|
- |
| 4.2,
Table 2 of IS:21 (Designation & Condition 51000-B, 'H2')(Elongation on 50 mm gauge length (For thickness over 2.6 to 6.3 mm)) |
- |
2000 |
|
- |
| 4.2,
Table 2 of IS:21 (Designation & Condition 51000-B, 'H1')(Elongation on 50 mm gauge length (For thickness over 2.6 to 6.3 mm)) |
- |
2000 |
|
- |
| 4.2,
Table 2 of IS:21 (Designation & Condition 51000-A, 'H3')(Elongation on 50 mm gauge length (For thickness over 2.6 to 6.3 mm)) |
- |
2000 |
|
- |
| 4.2,
Table 2 of IS:21 (Designation & Condition 51000-A, 'H2')(Elongation on 50 mm gauge length (For thickness over 2.6 to 6.3 mm)) |
- |
2000 |
|
- |
| 4.2,
Table 2 of IS:21 (Designation & Condition 51000-A, 'H1')(Elongation on 50 mm gauge length (For thickness over 2.6 to 6.3 mm)) |
- |
2000 |
|
- |
| 4.2,
Table 2 of IS:21 (Designation & Condition 51000-A, 'O')(Elongation on 50 mm gauge length (For thickness over 2.6 to 6.3 mm)) |
- |
2000 |
|
- |
| 4.2,
Table 2 of IS:21 (Designation & Condition 40800, 'H4')(Elongation on 50 mm gauge length (For thickness over 2.6 to 6.3 mm)) |
- |
2000 |
|
- |
| 4.2,
Table 2 of IS:21 (Designation & Condition 40800, 'H3')(Elongation on 50 mm gauge length (For thickness over 2.6 to 6.3 mm)) |
- |
2000 |
|
- |
| 4.2,
Table 2 of IS:21 (Designation & Condition 40800, 'H2')(Elongation on 50 mm gauge length (For thickness over 2.6 to 6.3 mm)) |
- |
2000 |
|
- |
| 4.2,
Table 2 of IS:21 (Designation & Condition 40800, 'H1')(Elongation on 50 mm gauge length (For thickness over 2.6 to 6.3 mm)) |
- |
2000 |
|
- |
| 4.2,
Table 2 of IS:21 (Designation & Condition 40800, 'O')(Elongation on 50 mm gauge length (For thickness over 2.6 to 6.3 mm)) |
- |
2000 |
|
- |
| 4.2,
Table 2 of IS:21 (Designation & Condition 31500, 'H4')(Elongation on 50 mm gauge length (For thickness over 2.6 to 6.3 mm)) |
- |
2000 |
|
- |
| 4.2,
Table 2 of IS:21 (Designation & Condition 31500, 'H3')(Elongation on 50 mm gauge length (For thickness over 2.6 to 6.3 mm)) |
- |
2000 |
|
- |
| 4.2,
Table 2 of IS:21 (Designation & Condition 31500, 'H2')(Elongation on 50 mm gauge length (For thickness over 2.6 to 6.3 mm)) |
- |
2000 |
|
- |
| 4.2,
Table 2 of IS:21 (Designation & Condition 31500, 'H1')(Elongation on 50 mm gauge length (For thickness over 2.6 to 6.3 mm)) |
- |
2000 |
|
- |
| 4.2,
Table 2 of IS:21 (Designation & Condition 31500, 'O')(Elongation on 50 mm gauge length (For thickness over 2.6 to 6.3 mm)) |
- |
2000 |
|
- |
| 4.2,
Table 2 of IS:21 (Designation & Condition 31000, 'H4')(Elongation on 50 mm gauge length (For thickness over 2.6 to 6.3 mm)) |
- |
2000 |
|
- |
| 4.2,
Table 2 of IS:21 (Designation & Condition 31000, 'H3')(Elongation on 50 mm gauge length (For thickness over 2.6 to 6.3 mm)) |
- |
2000 |
|
- |
| 4.2,
Table 2 of IS:21 (Designation & Condition 31000, 'H2')(Elongation on 50 mm gauge length (For thickness over 2.6 to 6.3 mm)) |
- |
2000 |
|
- |
| 4.2,
Table 2 of IS:21 (Designation & Condition 31000, 'H1')(Elongation on 50 mm gauge length (For thickness over 2.6 to 6.3 mm)) |
- |
2000 |
|
- |
| 4.2,
Table 2 of IS:21 (Designation & Condition 31000, 'O')(Elongation on 50 mm gauge length (For thickness over 2.6 to 6.3 mm)) |
- |
2000 |
|
- |
| 4.2,
Table 2 of IS:21 (Designation & Condition 19600, 'H4')(Elongation on 50 mm gauge length (For thickness over 2.6 to 6.3 mm)) |
- |
2000 |
|
- |
| 4.2,
Table 2 of IS:21 (Designation & Condition 19600, 'H2')(Elongation on 50 mm gauge length (For thickness over 2.6 to 6.3 mm)) |
- |
2000 |
|
- |
| 4.2,
Table 2 of IS:21 (Designation & Condition 19600, 'O')(Elongation on 50 mm gauge length (For thickness over 2.6 to 6.3 mm)) |
- |
2000 |
|
- |
| 4.2,
Table 2 of IS:21 (Designation & Condition 19500, 'H4')(Elongation on 50 mm gauge length (For thickness over 2.6 to 6.3 mm)) |
- |
2000 |
|
- |
| 4.2,
Table 2 of IS:21 (Designation & Condition 19500, 'H2')(Elongation on 50 mm gauge length (For thickness over 2.6 to 6.3 mm)) |
- |
2000 |
|
- |
| 4.2,
Table 2 of IS:21 (Designation & Condition 19500, 'O')(Elongation on 50 mm gauge length (For thickness over 2.6 to 6.3 mm)) |
- |
2000 |
|
- |
| 4.2,
Table 2 of IS:21 (Designation & Condition 19000, 'H4')(Elongation on 50 mm gauge length (For thickness over 2.6 to 6.3 mm)) |
- |
2000 |
|
- |
| 4.2,
Table 2 of IS:21 (Designation & Condition 19000, 'H3')(Elongation on 50 mm gauge length (For thickness over 2.6 to 6.3 mm)) |
- |
2000 |
|
- |
| 4.2,
Table 2 of IS:21 (Designation & Condition 19000, 'H2')(Elongation on 50 mm gauge length (For thickness over 2.6 to 6.3 mm)) |
- |
2000 |
|
- |
| 4.2,
Table 2 of IS:21 (Designation & Condition 19000, 'H1')(Elongation on 50 mm gauge length (For thickness over 2.6 to 6.3 mm)) |
- |
2000 |
|
- |
| 4.2,
Table 2 of IS:21 (Designation & Condition 19000, 'O')(Elongation on 50 mm gauge length (For thickness over 2.6 to 6.3 mm)) |
- |
2000 |
|
- |
| 4.2,
Table 2 of IS:21 (Designation & Condition 64430, WP')(Bend Test (Radius of Bend)) |
- |
2000 |
|
- |
| 4.2,
Table 2 of IS:21 (Designation & Condition 64430, 'W')(Bend Test (Radius of Bend)) |
- |
2000 |
|
- |
| 4.2,
Table 2 of IS:21 (Designation & Condition 64430, 'O')(Bend Test (Radius of Bend)) |
- |
2000 |
|
- |
| 4.2,
Table 2 of IS:21 (Designation & Condition 51000-B, 'H4')(Bend Test (Radius of Bend)) |
- |
2000 |
|
- |
| 4.2,
Table 2 of IS:21 (Designation & Condition 51000-B, 'H3')(Bend Test (Radius of Bend)) |
- |
2000 |
|
- |
| 4.2,
Table 2 of IS:21 (Designation & Condition 51000-B, 'H2')(Bend Test (Radius of Bend)) |
- |
2000 |
|
- |
| 4.2,
Table 2 of IS:21 (Designation & Condition 51000-B, 'H1')(Bend Test (Radius of Bend)) |
- |
2000 |
|
- |
| 4.2,
Table 2 of IS:21 (Designation & Condition 51000-A, 'H3')(Bend Test (Radius of Bend)) |
- |
2000 |
|
- |
| 4.2,
Table 2 of IS:21 (Designation & Condition 51000-A, 'H2')(Bend Test (Radius of Bend)) |
- |
2000 |
|
- |
| 4.2,
Table 2 of IS:21 (Designation & Condition 51000-A, 'H1')(Bend Test (Radius of Bend)) |
- |
2000 |
|
- |
| 4.2,
Table 2 of IS:21 (Designation & Condition 51000-A, 'O')(Bend Test (Radius of Bend)) |
- |
2000 |
|
- |
| 4.2,
Table 2 of IS:21 (Designation & Condition 40800, 'H4')(Bend Test (Radius of Bend)) |
- |
2000 |
|
- |
| 4.2,
Table 2 of IS:21 (Designation & Condition 40800, 'H3')(Bend Test (Radius of Bend)) |
- |
2000 |
|
- |
| 4.2,
Table 2 of IS:21 (Designation & Condition 40800, 'H2')(Bend Test (Radius of Bend)) |
- |
2000 |
|
- |
| 4.2,
Table 2 of IS:21 (Designation & Condition 40800, 'H1')(Bend Test (Radius of Bend)) |
- |
2000 |
|
- |
| 4.2,
Table 2 of IS:21 (Designation & Condition 40800, 'O')(Bend Test (Radius of Bend)) |
- |
2000 |
|
- |
| 4.2,
Table 2 of IS:21 (Designation & Condition 31500, 'H4')(Bend Test (Radius of Bend)) |
- |
2000 |
|
- |
| 4.2,
Table 2 of IS:21 (Designation & Condition 31500, 'H3')(Bend Test (Radius of Bend)) |
- |
2000 |
|
- |
| 4.2,
Table 2 of IS:21 (Designation & Condition 31500, 'H2')(Bend Test (Radius of Bend)) |
- |
2000 |
|
- |
| 4.2,
Table 2 of IS:21 (Designation & Condition 31500, 'H1')(Bend Test (Radius of Bend)) |
- |
2000 |
|
- |
| 4.2,
Table 2 of IS:21 (Designation & Condition 31500, 'O')(Bend Test (Radius of Bend)) |
- |
2000 |
|
- |
| 4.2,
Table 2 of IS:21 (Designation & Condition 31000, 'H4')(Bend Test (Radius of Bend)) |
- |
2000 |
|
- |
| 4.2,
Table 2 of IS:21 (Designation & Condition 31000, 'H3')(Bend Test (Radius of Bend)) |
- |
2000 |
|
- |
| 4.2,
Table 2 of IS:21 (Designation & Condition 31000, 'H2')(Bend Test (Radius of Bend)) |
- |
2000 |
|
- |
| 4.2,
Table 2 of IS:21 (Designation & Condition 31000, 'H1')(Bend Test (Radius of Bend)) |
- |
2000 |
|
- |
| 4.2,
Table 2 of IS:21 (Designation & Condition 31000, 'O')(Bend Test (Radius of Bend)) |
- |
2000 |
|
- |
| 4.2,
Table 2 of IS:21 (Designation & Condition 19600, 'H4')(Bend Test (Radius of Bend)) |
- |
2000 |
|
- |
| 4.2,
Table 2 of IS:21 (Designation & Condition 19600, 'H2')(Bend Test (Radius of Bend)) |
- |
2000 |
|
- |
| 4.2,
Table 2 of IS:21 (Designation & Condition 19600, 'O')(Bend Test (Radius of Bend)) |
- |
2000 |
|
- |
| 4.2,
Table 2 of IS:21 (Designation & Condition 19500, 'H4')(Bend Test (Radius of Bend)) |
- |
2000 |
|
- |
| 4.2,
Table 2 of IS:21 (Designation & Condition 19500, 'H2')(Bend Test (Radius of Bend)) |
- |
2000 |
|
- |
| 4.2,
Table 2 of IS:21 (Designation & Condition 19500, 'O')(Bend Test (Radius of Bend)) |
- |
2000 |
|
- |
| 4.2,
Table 2 of IS:21 (Designation & Condition 19000, 'H4')(Bend Test (Radius of Bend)) |
- |
2000 |
|
- |
| 4.2,
Table 2 of IS:21 (Designation & Condition 19000, 'H3')(Bend Test (Radius of Bend)) |
- |
2000 |
|
- |
| 4.2,
Table 2 of IS:21 (Designation & Condition 19000, 'H2')(Bend Test (Radius of Bend)) |
- |
2000 |
|
- |
| 4.2,
Table 2 of IS:21 (Designation & Condition 19000, 'H1')(Bend Test (Radius of Bend)) |
- |
2000 |
|
- |
| 4.2,
Table 2 of IS:21 (Designation & Condition 19000, 'O')(Bend Test (Radius of Bend)) |
- |
2000 |
|
- |
| 5(Marking) |
- |
300 |
|
- |
|
26 Sep, 2027 |
- - |
| 4505 |
Ace Test Labs & Metrology Pvt. Ltd., Sonipat
| 9162826
| IS 11188 : Part 1 (2021) |
Vault Strong Room doors Part 1 specification |
- |
298000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 11.1 (3)(Fire and stream hose IS 11188 (Part 3)) |
- |
15000 |
|
- |
| 11.1 (2)(Fire endurance IS 11188 (Part 3)) |
- |
150000 |
|
- |
| 11.1 (1)(Burglary resistance IS 11188 (Part 2)) |
- |
150000 |
|
- |
| 10.4(Alternate to Cl 10.4) |
- |
15000 |
|
- |
| 10.3(Cross Hatch Test) |
- |
15000 |
|
- |
| 10(FINISH) |
- |
15000 |
|
- |
| 9.4(Vault Lighting Control) |
- |
15000 |
|
- |
| 9.3(Foot Bridge) |
- |
15000 |
|
- |
| 9.2(Handles) |
- |
15000 |
|
- |
| 9.1.1(Adjusting Bolt) |
- |
15000 |
|
- |
| 9.1(Hinges) |
- |
15000 |
|
- |
| 9(DOOR FITTINGS) |
- |
15000 |
|
- |
| 8.4.5(Automatic Relocking Device) |
- |
15000 |
|
- |
| 8.4.4(Time Lock) |
- |
15000 |
|
- |
| 8.4(Lock) |
- |
15000 |
|
- |
| 8.3.2.2(Construction) |
- |
15000 |
|
- |
| 8.3.2.1(The number of bolts and their minimum dimension) |
- |
15000 |
|
- |
| 8.3.2(Bolt Work) |
- |
15000 |
|
- |
| 8.3.1(Lock Case) |
- |
15000 |
|
- |
| 8.3(Locking Mechanism) |
- |
15000 |
|
- |
| 8.2.3(Crane Hinge Mechanism) |
- |
15000 |
|
- |
| 8.2.2(Compression Mechanism) |
- |
15000 |
|
- |
| 8.2.1(Rebate of the Door Frame) |
- |
15000 |
|
- |
| 8.2(Doors Frame) |
- |
15000 |
|
- |
| 8.1.2(Main Door (Outside)) |
- |
15000 |
|
- |
| 8.1.1(Ventilating Grill Gate (Inside)) |
- |
15000 |
|
- |
| 8.1 Fig. 1(Doors) |
- |
15000 |
|
- |
| 8(CONSTRUCTION AND GENERALREQUIREMENTS) |
- |
15000 |
|
- |
| 5 Table 1(bolts, Min) |
- |
15000 |
|
- |
| 5 Table 1(xix) Depth of engagement of shooting) |
- |
15000 |
|
- |
| 5 Table 1(cross sectional area, Min,sq mm) |
- |
15000 |
|
- |
| 5 Table 1(xviii) Diameter of shooting bolts, Min) |
- |
15000 |
|
- |
| 5 Table 1(xvi) Number of shooting bolts at top,Min) |
- |
15000 |
|
- |
| 5 Table 1(xv) Number of shooting bolts on opposite side,Min) |
- |
15000 |
|
- |
| 5 Table 1(xiv) Number of shooting bolts on hinge side, Min) |
- |
15000 |
|
- |
| 5 Table 1(xiii) Number of locks) |
- |
15000 |
|
- |
| 5 Table 1(xii) Wall thickness (recommendation)) |
- |
15000 |
|
- |
| 5 Table 1(xi) Thickness of drill and oxyacetylene
torch resisting layer (excluding mild steel plates),Min) |
- |
15000 |
|
- |
| 5 Table 1(ix) Thickness of doors slab, thickness over rebate) |
- |
15000 |
|
- |
| 5 Table 1(viii) Pitch of grill gate rods) |
- |
15000 |
|
- |
| 5 Table 1(vii) Diameter of grill gate rods, Min) |
- |
15000 |
|
- |
| 5 Table 1(vi) Thickens of grill gate angles or
section made out of M.S. plates, Min) |
- |
15000 |
|
- |
| 5 Table 1(v) Dimension of the rebate coming under shear) |
- |
15000 |
|
- |
| 5 Table 1(iv (b) Thickness of door frame, if
fabricated from single plate to form
channel/multi-bend section, Min) |
- |
15000 |
|
- |
| 5 Table 1(ii (a) Height H, Min b) Width W, Min
iv(a) Thickness of door frame angle,
channel or section made out of M.S.
plates, if built up to form a channel,Min) |
- |
15000 |
|
- |
| 5 Table 1(iii) Inside dimension or clear opening when
door shutters are swung open at 180 degree) |
- |
15000 |
|
- |
| 5 Table 1(ii (b) Width W) |
- |
15000 |
|
- |
| 5 Table 1(ii (a) Height, H) |
- |
15000 |
|
- |
| 5 Table 1(ii) Overall dimension of vault door) |
- |
15000 |
|
- |
| 5 Table 1(i) Door Type) |
- |
15000 |
|
- |
| 4(Type) |
- |
15000 |
|
- |
| 5(Table-1)(Type of Door) |
- |
15000 |
|
- |
| 5(Table-1)(Overall dimesion of door) |
- |
15000 |
|
- |
| 5(Table-1)(Inside dimension or clear opening of door) |
- |
15000 |
|
- |
| 5(Table-1)(Thickness of door frame angle-made of Plate,if bulit up to form a channel) |
- |
15000 |
|
- |
| 5(Table-1)(Thickness of door frame ,if fabricated or multibend) |
- |
15000 |
|
- |
| 5(Table-1)(Dimension of the rebate coming under share) |
- |
15000 |
|
- |
| 5(Table-1)(Thickness of grill gate angle/section) |
- |
15000 |
|
- |
| 5(Table-1)(Diameter of grill gate rod) |
- |
15000 |
|
- |
| 5(Table-1)(Pitch of grill gate rod) |
- |
15000 |
|
- |
| 5(Table-1)(Thickness of door slab,thickness over rebate) |
- |
15000 |
|
- |
| 5(Table-1)(Thickness of the door over lock) |
- |
15000 |
|
- |
| 5(Table-1)(Thickness of drill & oxyacetylene torch resis. layer(exclue MS plate) |
- |
15000 |
|
- |
| 5(Table-1)(Wall thickness) |
- |
15000 |
|
- |
| 5(Table-1)(Number of locks) |
- |
15000 |
|
- |
| 5(Table-1)(Number of shooting bolys on hinge side) |
- |
15000 |
|
- |
| 5(Table-1)(Number of shooting bolts on opposite) |
- |
15000 |
|
- |
| 5(Table-1)(Number of shooting bolts at top) |
- |
15000 |
|
- |
| 5(Table-1)(Number of shooting bolts at bottom) |
- |
15000 |
|
- |
| 5(Table-1)(Cross sectional area as per shooting bolt) |
- |
15000 |
|
- |
| 5(Table-1)(Depth engagement of shooting) |
- |
15000 |
|
- |
| 6(Materail) |
- |
15000 |
|
- |
| 7(Classification) |
- |
15000 |
|
- |
| 8 & 8.1.1(Ventilating Grill Gate (Inside)) |
- |
15000 |
|
- |
| 8.1.1.1(Locking device (unpickable dual control lock)) |
- |
15000 |
|
- |
| 8.1.2(Main Door- Outer & inner plate thickness) |
- |
15000 |
|
- |
| 8.1.2.1(Door(Finish &Gap of frame/edge with any place)) |
- |
15000 |
|
- |
| 8.2(Door frame (No.of barckets & Size for gripping)) |
- |
15000 |
|
- |
| 8.2.1(Rebate of the door frame) |
- |
15000 |
|
- |
| 8.2.2(Compression mechanism) |
- |
15000 |
|
- |
| 8.2.3(Crane hinge mechanism) |
- |
15000 |
|
- |
| 8.3(Lock case) |
- |
15000 |
|
- |
| 8.3.2(Bolt work) |
- |
15000 |
|
- |
| 8.3.2.2(Construction (of bolt work)) |
- |
15000 |
|
- |
| 8.3.2.3(Bearing piller) |
- |
15000 |
|
- |
| 8.4.1(Shooting bolt control (By lock)) |
- |
15000 |
|
- |
| 8.4.2(Test of key-Lock) |
- |
15000 |
|
- |
| 8.4.3(Lock fixing bolts) |
- |
15000 |
|
- |
| 8.4.4(Time lock) |
- |
15000 |
|
- |
| 8.4.5(Automatic Relocking devise) |
- |
15000 |
|
- |
| 9 &9.1(Hinges) |
- |
15000 |
|
- |
| 9.1.1(Adjusting bolt) |
- |
15000 |
|
- |
| 9.2(Handles) |
- |
15000 |
|
- |
| 9.3(Foot bringe) |
- |
15000 |
|
- |
| 9.4(Vault lighting control) |
- |
15000 |
|
- |
| 10 &10.1(Dents,Burrs & Edges) |
- |
15000 |
|
- |
| 10.2(Colour coating thickness (Surafce paint)) |
- |
15000 |
|
- |
| 10.3(Cross Hatch test) |
- |
15000 |
|
- |
| 10.4(Door (Stainless cladding)) |
- |
15000 |
|
- |
| 11.1 &11.2(Test criteria for confomity -Burglaty attack) |
- |
15000 |
|
- |
| 11.1 &11.2(Test criteria for confomity -Fire resistancey) |
- |
15000 |
|
- |
| 12(Marking of door) |
- |
15000 |
|
- |
| 12.2(Marking on keys) |
- |
15000 |
|
- |
| 4(Type) |
- |
15000 |
|
- |
| 5(Table-1)(5(Table-1)) |
- |
15000 |
|
- |
| 5(Table-1)(Overall dimesion of door) |
- |
15000 |
|
- |
| 5(Table-1)(Inside dimension or clear opening of door) |
- |
15000 |
|
- |
| 5(Table-1)(Thickness of door frame angle-made of Plate,if bulit up to form a channel) |
- |
15000 |
|
- |
| 5(Table-1)(Thickness of door frame ,if fabricated or multibend) |
- |
15000 |
|
- |
| 5(Table-1)(Dimension of the rebate coming under share) |
- |
15000 |
|
- |
| 5(Table-1)(Thickness of grill gate angle/section) |
- |
15000 |
|
- |
| 5(Table-1)(Diameter of grill gate rod) |
- |
15000 |
|
- |
| 5(Table-1)(Pitch of grill gate rod) |
- |
15000 |
|
- |
| 5(Table-1)(Thickness of door slab,thickness over rebate) |
- |
15000 |
|
- |
| 5(Table-1)(Thickness of the door over lock) |
- |
15000 |
|
- |
| 5(Table-1)(Thickness of drill & oxyacetylene torch resis. layer(exclue MS plate) |
- |
15000 |
|
- |
| 5(Table-1)(Wall thickness) |
- |
15000 |
|
- |
| 5(Table-1)(Number of locks) |
- |
15000 |
|
- |
| 5(Table-1)(Number of shooting bolys on hinge side) |
- |
15000 |
|
- |
| 5(Table-1)(Number of shooting bolts at top) |
- |
15000 |
|
- |
| 5(Table-1)(Number of shooting bolts at bottom) |
- |
15000 |
|
- |
| 5(Table-1)(Cross sectional area as per shooting bolt) |
- |
15000 |
|
- |
| 5(Table-1)(Depth engagement of shooting) |
- |
15000 |
|
- |
| 6(Materail) |
- |
15000 |
|
- |
| 7(Classification) |
- |
15000 |
|
- |
| 8 & 8.1.1(Ventilating Grill Gate (Inside)) |
- |
15000 |
|
- |
| 8.1.1.1(Locking device (unpickable dual control lock)) |
- |
15000 |
|
- |
| 8.1.2(Main Door- Outer & inner plate thickness) |
- |
15000 |
|
- |
| 8.1.2.1(Door(Finish &Gap of frame/edge with any place)) |
- |
15000 |
|
- |
| 8.2(Door frame (No.of barckets & Size for gripping)) |
- |
15000 |
|
- |
| 8.2.1(Rebate of the door frame) |
- |
15000 |
|
- |
| 8.2.2(Compression mechanism) |
- |
15000 |
|
- |
| 8.2.3(Crane hinge mechanism) |
- |
15000 |
|
- |
| 8.3(Lock case) |
- |
15000 |
|
- |
| 8.3.2(Bolt work) |
- |
15000 |
|
- |
| 8.3.2.2(Construction (of bolt work)) |
- |
15000 |
|
- |
| 8.3.2.3(Bearing piller) |
- |
15000 |
|
- |
| 8.4.1(Shooting bolt control (By lock)) |
- |
15000 |
|
- |
| 8.4.2(Test of key-Lock) |
- |
15000 |
|
- |
| 8.4.3(Lock fixing bolts) |
- |
15000 |
|
- |
| 8.4.4(Time lock) |
- |
15000 |
|
- |
| 8.4.5(Automatic Relocking devise) |
- |
15000 |
|
- |
| 9 &9.1(Hinges) |
- |
15000 |
|
- |
| 9.1.1(Adjusting bolt) |
- |
15000 |
|
- |
| 9.3(Foot bringe) |
- |
15000 |
|
- |
| 9.4(Vault lighting control) |
- |
15000 |
|
- |
| 10 &10.1(Dents,Burrs & Edges) |
- |
15000 |
|
- |
| 10.2(Colour coating thickness (Surafce paint)) |
- |
15000 |
|
- |
| 10.3(Cross Hatch test) |
- |
15000 |
|
- |
| 10.4(Door (Stainless cladding)) |
- |
15000 |
|
- |
| 11.1 &11.2(Test criteria for confomity -Burglaty attack) |
- |
15000 |
|
- |
| 11.1 &11.2(Test criteria for confomity -Fire resistancey) |
- |
15000 |
|
- |
| 12(Marking of door) |
- |
15000 |
|
- |
| 12.2(Marking on keys) |
- |
15000 |
|
- |
| 11.1 (3)(Fire and stream hose IS 11188 (Part 3)) |
- |
15000 |
|
- |
| 11.1 (2)(Fire endurance IS 11188 (Part 3)) |
- |
150000 |
|
- |
| 11.1 (1)(Burglary resistance IS 11188 (Part 2)) |
- |
150000 |
|
- |
| 10.4(Alternate to Cl 10.4) |
- |
15000 |
|
- |
| 10.3(Cross Hatch Test) |
- |
15000 |
|
- |
| 10(FINISH) |
- |
15000 |
|
- |
| 9.4(Vault Lighting Control) |
- |
15000 |
|
- |
| 9.3(Foot Bridge) |
- |
15000 |
|
- |
| 9.2(Handles) |
- |
15000 |
|
- |
| 9.1.1(Adjusting Bolt) |
- |
15000 |
|
- |
| 9.1(Hinges) |
- |
15000 |
|
- |
| 9(DOOR FITTINGS) |
- |
15000 |
|
- |
| 8.4.5(Automatic Relocking Device) |
- |
15000 |
|
- |
| 8.4.4(Time Lock) |
- |
15000 |
|
- |
| 8.4(Lock) |
- |
15000 |
|
- |
| 8.3.2.2(Construction) |
- |
15000 |
|
- |
| 8.3.2.1(The number of bolts and their minimum dimension) |
- |
15000 |
|
- |
| 8.3.2(Bolt Work) |
- |
15000 |
|
- |
| 8.3.1(Lock Case) |
- |
15000 |
|
- |
| 8.3(Locking Mechanism) |
- |
15000 |
|
- |
| 8.2.3(Crane Hinge Mechanism) |
- |
15000 |
|
- |
| 8.2.2(Compression Mechanism) |
- |
15000 |
|
- |
| 8.2.1(Rebate of the Door Frame) |
- |
15000 |
|
- |
| 8.2(Doors Frame) |
- |
15000 |
|
- |
| 8.1.2(Main Door (Outside)) |
- |
15000 |
|
- |
| 8.1.1(Ventilating Grill Gate (Inside)) |
- |
15000 |
|
- |
| 8.1 Fig. 1(Doors) |
- |
15000 |
|
- |
| 8(CONSTRUCTION AND GENERALREQUIREMENTS) |
- |
15000 |
|
- |
| 5 Table 1(bolts, Min) |
- |
15000 |
|
- |
| 5 Table 1(xix) Depth of engagement of shooting) |
- |
15000 |
|
- |
| 5 Table 1(cross sectional area, Min,sq mm) |
- |
15000 |
|
- |
| 5 Table 1(xviii) Diameter of shooting bolts, Min) |
- |
15000 |
|
- |
| 5 Table 1(xvi) Number of shooting bolts at top,Min) |
- |
15000 |
|
- |
| 5 Table 1(xv) Number of shooting bolts on opposite side,Min) |
- |
15000 |
|
- |
| 5 Table 1(xiv) Number of shooting bolts on hinge side, Min) |
- |
15000 |
|
- |
| 5 Table 1(xiii) Number of locks) |
- |
15000 |
|
- |
| 5 Table 1(xii) Wall thickness (recommendation)) |
- |
15000 |
|
- |
| 5 Table 1(xi) Thickness of drill and oxyacetylene
torch resisting layer (excluding mild steel plates),Min) |
- |
15000 |
|
- |
| 5 Table 1(ix) Thickness of doors slab, thickness over rebate) |
- |
15000 |
|
- |
| 5 Table 1(viii) Pitch of grill gate rods) |
- |
15000 |
|
- |
| 5 Table 1(vii) Diameter of grill gate rods, Min) |
- |
15000 |
|
- |
| 5 Table 1(vi) Thickens of grill gate angles or
section made out of M.S. plates, Min) |
- |
15000 |
|
- |
| 5 Table 1(v) Dimension of the rebate coming under shear) |
- |
15000 |
|
- |
| 5 Table 1(iv (b) Thickness of door frame, if
fabricated from single plate to form
channel/multi-bend section, Min) |
- |
15000 |
|
- |
| 5 Table 1(ii (a) Height H, Min b) Width W, Min
iv(a) Thickness of door frame angle,
channel or section made out of M.S.
plates, if built up to form a channel,Min) |
- |
15000 |
|
- |
| 5 Table 1(iii) Inside dimension or clear opening when
door shutters are swung open at 180 degree) |
- |
15000 |
|
- |
| 5 Table 1(ii (b) Width W) |
- |
15000 |
|
- |
| 5 Table 1(ii (a) Height, H) |
- |
15000 |
|
- |
| 5 Table 1(ii) Overall dimension of vault door) |
- |
15000 |
|
- |
| 5 Table 1(i) Door Type) |
- |
15000 |
|
- |
| 4(Type) |
- |
15000 |
|
- |
| 5(Table-1)(Type of Door) |
- |
15000 |
|
- |
| 5(Table-1)(Overall dimesion of door) |
- |
15000 |
|
- |
| 5(Table-1)(Inside dimension or clear opening of door) |
- |
15000 |
|
- |
| 5(Table-1)(Thickness of door frame angle-made of Plate,if bulit up to form a channel) |
- |
15000 |
|
- |
| 5(Table-1)(Thickness of door frame ,if fabricated or multibend) |
- |
15000 |
|
- |
| 5(Table-1)(Dimension of the rebate coming under share) |
- |
15000 |
|
- |
| 5(Table-1)(Thickness of grill gate angle/section) |
- |
15000 |
|
- |
| 5(Table-1)(Diameter of grill gate rod) |
- |
15000 |
|
- |
| 5(Table-1)(Pitch of grill gate rod) |
- |
15000 |
|
- |
| 5(Table-1)(Thickness of door slab,thickness over rebate) |
- |
15000 |
|
- |
| 5(Table-1)(Thickness of the door over lock) |
- |
15000 |
|
- |
| 5(Table-1)(Thickness of drill & oxyacetylene torch resis. layer(exclue MS plate) |
- |
15000 |
|
- |
| 5(Table-1)(Wall thickness) |
- |
15000 |
|
- |
| 5(Table-1)(Number of locks) |
- |
15000 |
|
- |
| 5(Table-1)(Number of shooting bolys on hinge side) |
- |
15000 |
|
- |
| 5(Table-1)(Number of shooting bolts on opposite) |
- |
15000 |
|
- |
| 5(Table-1)(Number of shooting bolts at top) |
- |
15000 |
|
- |
| 5(Table-1)(Number of shooting bolts at bottom) |
- |
15000 |
|
- |
| 5(Table-1)(Cross sectional area as per shooting bolt) |
- |
15000 |
|
- |
| 5(Table-1)(Depth engagement of shooting) |
- |
15000 |
|
- |
| 6(Materail) |
- |
15000 |
|
- |
| 7(Classification) |
- |
15000 |
|
- |
| 8 & 8.1.1(Ventilating Grill Gate (Inside)) |
- |
15000 |
|
- |
| 8.1.1.1(Locking device (unpickable dual control lock)) |
- |
15000 |
|
- |
| 8.1.2(Main Door- Outer & inner plate thickness) |
- |
15000 |
|
- |
| 8.1.2.1(Door(Finish &Gap of frame/edge with any place)) |
- |
15000 |
|
- |
| 8.2(Door frame (No.of barckets & Size for gripping)) |
- |
15000 |
|
- |
| 8.2.1(Rebate of the door frame) |
- |
15000 |
|
- |
| 8.2.2(Compression mechanism) |
- |
15000 |
|
- |
| 8.2.3(Crane hinge mechanism) |
- |
15000 |
|
- |
| 8.3(Lock case) |
- |
15000 |
|
- |
| 8.3.2(Bolt work) |
- |
15000 |
|
- |
| 8.3.2.2(Construction (of bolt work)) |
- |
15000 |
|
- |
| 8.3.2.3(Bearing piller) |
- |
15000 |
|
- |
| 8.4.1(Shooting bolt control (By lock)) |
- |
15000 |
|
- |
| 8.4.2(Test of key-Lock) |
- |
15000 |
|
- |
| 8.4.3(Lock fixing bolts) |
- |
15000 |
|
- |
| 8.4.4(Time lock) |
- |
15000 |
|
- |
| 8.4.5(Automatic Relocking devise) |
- |
15000 |
|
- |
| 9 &9.1(Hinges) |
- |
15000 |
|
- |
| 9.1.1(Adjusting bolt) |
- |
15000 |
|
- |
| 9.2(Handles) |
- |
15000 |
|
- |
| 9.3(Foot bringe) |
- |
15000 |
|
- |
| 9.4(Vault lighting control) |
- |
15000 |
|
- |
| 10 &10.1(Dents,Burrs & Edges) |
- |
15000 |
|
- |
| 10.2(Colour coating thickness (Surafce paint)) |
- |
15000 |
|
- |
| 10.3(Cross Hatch test) |
- |
15000 |
|
- |
| 10.4(Door (Stainless cladding)) |
- |
15000 |
|
- |
| 11.1 &11.2(Test criteria for confomity -Burglaty attack) |
- |
15000 |
|
- |
| 11.1 &11.2(Test criteria for confomity -Fire resistancey) |
- |
15000 |
|
- |
| 12(Marking of door) |
- |
15000 |
|
- |
| 12.2(Marking on keys) |
- |
15000 |
|
- |
| 4(Type) |
- |
15000 |
|
- |
| 5(Table-1)(5(Table-1)) |
- |
15000 |
|
- |
| 5(Table-1)(Overall dimesion of door) |
- |
15000 |
|
- |
| 5(Table-1)(Inside dimension or clear opening of door) |
- |
15000 |
|
- |
| 5(Table-1)(Thickness of door frame angle-made of Plate,if bulit up to form a channel) |
- |
15000 |
|
- |
| 5(Table-1)(Thickness of door frame ,if fabricated or multibend) |
- |
15000 |
|
- |
| 5(Table-1)(Dimension of the rebate coming under share) |
- |
15000 |
|
- |
| 5(Table-1)(Thickness of grill gate angle/section) |
- |
15000 |
|
- |
| 5(Table-1)(Diameter of grill gate rod) |
- |
15000 |
|
- |
| 5(Table-1)(Pitch of grill gate rod) |
- |
15000 |
|
- |
| 5(Table-1)(Thickness of door slab,thickness over rebate) |
- |
15000 |
|
- |
| 5(Table-1)(Thickness of the door over lock) |
- |
15000 |
|
- |
| 5(Table-1)(Thickness of drill & oxyacetylene torch resis. layer(exclue MS plate) |
- |
15000 |
|
- |
| 5(Table-1)(Wall thickness) |
- |
15000 |
|
- |
| 5(Table-1)(Number of locks) |
- |
15000 |
|
- |
| 5(Table-1)(Number of shooting bolys on hinge side) |
- |
15000 |
|
- |
| 5(Table-1)(Number of shooting bolts at top) |
- |
15000 |
|
- |
| 5(Table-1)(Number of shooting bolts at bottom) |
- |
15000 |
|
- |
| 5(Table-1)(Cross sectional area as per shooting bolt) |
- |
15000 |
|
- |
| 5(Table-1)(Depth engagement of shooting) |
- |
15000 |
|
- |
| 6(Materail) |
- |
15000 |
|
- |
| 7(Classification) |
- |
15000 |
|
- |
| 8 & 8.1.1(Ventilating Grill Gate (Inside)) |
- |
15000 |
|
- |
| 8.1.1.1(Locking device (unpickable dual control lock)) |
- |
15000 |
|
- |
| 8.1.2(Main Door- Outer & inner plate thickness) |
- |
15000 |
|
- |
| 8.1.2.1(Door(Finish &Gap of frame/edge with any place)) |
- |
15000 |
|
- |
| 8.2(Door frame (No.of barckets & Size for gripping)) |
- |
15000 |
|
- |
| 8.2.1(Rebate of the door frame) |
- |
15000 |
|
- |
| 8.2.2(Compression mechanism) |
- |
15000 |
|
- |
| 8.2.3(Crane hinge mechanism) |
- |
15000 |
|
- |
| 8.3(Lock case) |
- |
15000 |
|
- |
| 8.3.2(Bolt work) |
- |
15000 |
|
- |
| 8.3.2.2(Construction (of bolt work)) |
- |
15000 |
|
- |
| 8.3.2.3(Bearing piller) |
- |
15000 |
|
- |
| 8.4.1(Shooting bolt control (By lock)) |
- |
15000 |
|
- |
| 8.4.2(Test of key-Lock) |
- |
15000 |
|
- |
| 8.4.3(Lock fixing bolts) |
- |
15000 |
|
- |
| 8.4.4(Time lock) |
- |
15000 |
|
- |
| 8.4.5(Automatic Relocking devise) |
- |
15000 |
|
- |
| 9 &9.1(Hinges) |
- |
15000 |
|
- |
| 9.1.1(Adjusting bolt) |
- |
15000 |
|
- |
| 9.3(Foot bringe) |
- |
15000 |
|
- |
| 9.4(Vault lighting control) |
- |
15000 |
|
- |
| 10 &10.1(Dents,Burrs & Edges) |
- |
15000 |
|
- |
| 10.2(Colour coating thickness (Surafce paint)) |
- |
15000 |
|
- |
| 10.3(Cross Hatch test) |
- |
15000 |
|
- |
| 10.4(Door (Stainless cladding)) |
- |
15000 |
|
- |
| 11.1 &11.2(Test criteria for confomity -Burglaty attack) |
- |
15000 |
|
- |
| 11.1 &11.2(Test criteria for confomity -Fire resistancey) |
- |
15000 |
|
- |
| 12(Marking of door) |
- |
5000 |
|
- |
| 12.2(Marking on keys) |
- |
5000 |
|
- |
| 11.1 (3)(Fire and stream hose IS 11188 (Part 3)) |
- |
15000 |
|
- |
| 11.1 (2)(Fire endurance IS 11188 (Part 3)) |
- |
150000 |
|
- |
| 11.1 (1)(Burglary resistance IS 11188 (Part 2)) |
- |
150000 |
|
- |
| 10.4(Alternate to Cl 10.4) |
- |
15000 |
|
- |
| 10.3(Cross Hatch Test) |
- |
15000 |
|
- |
| 10(FINISH) |
- |
15000 |
|
- |
| 9.4(Vault Lighting Control) |
- |
15000 |
|
- |
| 9.3(Foot Bridge) |
- |
15000 |
|
- |
| 9.2(Handles) |
- |
15000 |
|
- |
| 9.1.1(Adjusting Bolt) |
- |
15000 |
|
- |
| 9.1(Hinges) |
- |
15000 |
|
- |
| 9(DOOR FITTINGS) |
- |
15000 |
|
- |
| 8.4.5(Automatic Relocking Device) |
- |
15000 |
|
- |
| 8.4.4(Time Lock) |
- |
15000 |
|
- |
| 8.4(Lock) |
- |
15000 |
|
- |
| 8.3.2.2(Construction) |
- |
15000 |
|
- |
| 8.3.2.1(The number of bolts and their minimum dimension) |
- |
15000 |
|
- |
| 8.3.2(Bolt Work) |
- |
15000 |
|
- |
| 8.3.1(Lock Case) |
- |
15000 |
|
- |
| 8.3(Locking Mechanism) |
- |
15000 |
|
- |
| 8.2.3(Crane Hinge Mechanism) |
- |
15000 |
|
- |
| 8.2.2(Compression Mechanism) |
- |
15000 |
|
- |
| 8.2.1(Rebate of the Door Frame) |
- |
15000 |
|
- |
| 8.2(Doors Frame) |
- |
15000 |
|
- |
| 8.1.2(Main Door (Outside)) |
- |
15000 |
|
- |
| 8.1.1(Ventilating Grill Gate (Inside)) |
- |
15000 |
|
- |
| 8.1 Fig. 1(Doors) |
- |
15000 |
|
- |
| 8(CONSTRUCTION AND GENERALREQUIREMENTS) |
- |
15000 |
|
- |
| 5 Table 1(bolts, Min) |
- |
15000 |
|
- |
| 5 Table 1(xix) Depth of engagement of shooting) |
- |
15000 |
|
- |
| 5 Table 1(cross sectional area, Min,sq mm) |
- |
15000 |
|
- |
| 5 Table 1(xviii) Diameter of shooting bolts, Min) |
- |
15000 |
|
- |
| 5 Table 1(xvi) Number of shooting bolts at top,Min) |
- |
15000 |
|
- |
| 5 Table 1(xv) Number of shooting bolts on opposite side,Min) |
- |
15000 |
|
- |
| 5 Table 1(xiv) Number of shooting bolts on hinge side, Min) |
- |
15000 |
|
- |
| 5 Table 1(xiii) Number of locks) |
- |
15000 |
|
- |
| 5 Table 1(xii) Wall thickness (recommendation)) |
- |
15000 |
|
- |
| 5 Table 1(xi) Thickness of drill and oxyacetylene
torch resisting layer (excluding mild steel plates),Min) |
- |
15000 |
|
- |
| 5 Table 1(ix) Thickness of doors slab, thickness over rebate) |
- |
15000 |
|
- |
| 5 Table 1(viii) Pitch of grill gate rods) |
- |
15000 |
|
- |
| 5 Table 1(vii) Diameter of grill gate rods, Min) |
- |
15000 |
|
- |
| 5 Table 1(vi) Thickens of grill gate angles or
section made out of M.S. plates, Min) |
- |
15000 |
|
- |
| 5 Table 1(v) Dimension of the rebate coming under shear) |
- |
15000 |
|
- |
| 5 Table 1(iv (b) Thickness of door frame, if
fabricated from single plate to form
channel/multi-bend section, Min) |
- |
15000 |
|
- |
| 5 Table 1(ii (a) Height H, Min b) Width W, Min
iv(a) Thickness of door frame angle,
channel or section made out of M.S.
plates, if built up to form a channel,Min) |
- |
15000 |
|
- |
| 5 Table 1(iii) Inside dimension or clear opening when
door shutters are swung open at 180 degree) |
- |
15000 |
|
- |
| 5 Table 1(ii (b) Width W) |
- |
15000 |
|
- |
| 5 Table 1(ii (a) Height, H) |
- |
15000 |
|
- |
| 5 Table 1(ii) Overall dimension of vault door) |
- |
15000 |
|
- |
| 5 Table 1(i) Door Type) |
- |
15000 |
|
- |
| 4(Type) |
- |
15000 |
|
- |
| 5(Table-1)(Type of Door) |
- |
15000 |
|
- |
| 5(Table-1)(Overall dimesion of door) |
- |
15000 |
|
- |
| 5(Table-1)(Inside dimension or clear opening of door) |
- |
15000 |
|
- |
| 5(Table-1)(Thickness of door frame angle-made of Plate,if bulit up to form a channel) |
- |
15000 |
|
- |
| 5(Table-1)(Thickness of door frame ,if fabricated or multibend) |
- |
15000 |
|
- |
| 5(Table-1)(Dimension of the rebate coming under share) |
- |
15000 |
|
- |
| 5(Table-1)(Thickness of grill gate angle/section) |
- |
15000 |
|
- |
| 5(Table-1)(Diameter of grill gate rod) |
- |
15000 |
|
- |
| 5(Table-1)(Pitch of grill gate rod) |
- |
15000 |
|
- |
| 5(Table-1)(Thickness of door slab,thickness over rebate) |
- |
15000 |
|
- |
| 5(Table-1)(Thickness of the door over lock) |
- |
15000 |
|
- |
| 5(Table-1)(Thickness of drill & oxyacetylene torch resis. layer(exclue MS plate) |
- |
15000 |
|
- |
| 5(Table-1)(Wall thickness) |
- |
15000 |
|
- |
| 5(Table-1)(Number of locks) |
- |
15000 |
|
- |
| 5(Table-1)(Number of shooting bolys on hinge side) |
- |
15000 |
|
- |
| 5(Table-1)(Number of shooting bolts on opposite) |
- |
15000 |
|
- |
| 5(Table-1)(Number of shooting bolts at top) |
- |
15000 |
|
- |
| 5(Table-1)(Number of shooting bolts at bottom) |
- |
15000 |
|
- |
| 5(Table-1)(Cross sectional area as per shooting bolt) |
- |
15000 |
|
- |
| 5(Table-1)(Depth engagement of shooting) |
- |
15000 |
|
- |
| 6(Materail) |
- |
15000 |
|
- |
| 7(Classification) |
- |
15000 |
|
- |
| 8 & 8.1.1(Ventilating Grill Gate (Inside)) |
- |
15000 |
|
- |
| 8.1.1.1(Locking device (unpickable dual control lock)) |
- |
15000 |
|
- |
| 8.1.2(Main Door- Outer & inner plate thickness) |
- |
15000 |
|
- |
| 8.1.2.1(Door(Finish &Gap of frame/edge with any place)) |
- |
15000 |
|
- |
| 8.2(Door frame (No.of barckets & Size for gripping)) |
- |
15000 |
|
- |
| 8.2.1(Rebate of the door frame) |
- |
15000 |
|
- |
| 8.2.2(Compression mechanism) |
- |
15000 |
|
- |
| 8.2.3(Crane hinge mechanism) |
- |
15000 |
|
- |
| 8.3(Lock case) |
- |
15000 |
|
- |
| 8.3.2(Bolt work) |
- |
15000 |
|
- |
| 8.3.2.2(Construction (of bolt work)) |
- |
15000 |
|
- |
| 8.3.2.3(Bearing piller) |
- |
15000 |
|
- |
| 8.4.1(Shooting bolt control (By lock)) |
- |
15000 |
|
- |
| 8.4.2(Test of key-Lock) |
- |
15000 |
|
- |
| 8.4.3(Lock fixing bolts) |
- |
15000 |
|
- |
| 8.4.4(Time lock) |
- |
15000 |
|
- |
| 8.4.5(Automatic Relocking devise) |
- |
15000 |
|
- |
| 9 &9.1(Hinges) |
- |
15000 |
|
- |
| 9.1.1(Adjusting bolt) |
- |
15000 |
|
- |
| 9.2(Handles) |
- |
15000 |
|
- |
| 9.3(Foot bringe) |
- |
15000 |
|
- |
| 9.4(Vault lighting control) |
- |
15000 |
|
- |
| 10 &10.1(Dents,Burrs & Edges) |
- |
15000 |
|
- |
| 10.2(Colour coating thickness (Surafce paint)) |
- |
15000 |
|
- |
| 10.3(Cross Hatch test) |
- |
15000 |
|
- |
| 10.4(Door (Stainless cladding)) |
- |
15000 |
|
- |
| 11.1 &11.2(Test criteria for confomity -Burglaty attack) |
- |
15000 |
|
- |
| 11.1 &11.2(Test criteria for confomity -Fire resistancey) |
- |
15000 |
|
- |
| 12(Marking of door) |
- |
15000 |
|
- |
| 12.2(Marking on keys) |
- |
15000 |
|
- |
| 4(Type) |
- |
15000 |
|
- |
| 5(Table-1)(5(Table-1)) |
- |
15000 |
|
- |
| 5(Table-1)(Overall dimesion of door) |
- |
15000 |
|
- |
| 5(Table-1)(Inside dimension or clear opening of door) |
- |
15000 |
|
- |
| 5(Table-1)(Thickness of door frame angle-made of Plate,if bulit up to form a channel) |
- |
15000 |
|
- |
| 5(Table-1)(Thickness of door frame ,if fabricated or multibend) |
- |
15000 |
|
- |
| 5(Table-1)(Dimension of the rebate coming under share) |
- |
15000 |
|
- |
| 5(Table-1)(Thickness of grill gate angle/section) |
- |
15000 |
|
- |
| 5(Table-1)(Diameter of grill gate rod) |
- |
15000 |
|
- |
| 5(Table-1)(Pitch of grill gate rod) |
- |
15000 |
|
- |
| 5(Table-1)(Thickness of door slab,thickness over rebate) |
- |
15000 |
|
- |
| 5(Table-1)(Thickness of the door over lock) |
- |
15000 |
|
- |
| 5(Table-1)(Thickness of drill & oxyacetylene torch resis. layer(exclue MS plate) |
- |
15000 |
|
- |
| 5(Table-1)(Wall thickness) |
- |
15000 |
|
- |
| 5(Table-1)(Number of locks) |
- |
15000 |
|
- |
| 5(Table-1)(Number of shooting bolys on hinge side) |
- |
15000 |
|
- |
| 5(Table-1)(Number of shooting bolts at top) |
- |
15000 |
|
- |
| 5(Table-1)(Number of shooting bolts at bottom) |
- |
15000 |
|
- |
| 5(Table-1)(Cross sectional area as per shooting bolt) |
- |
15000 |
|
- |
| 5(Table-1)(Depth engagement of shooting) |
- |
15000 |
|
- |
| 6(Materail) |
- |
15000 |
|
- |
| 7(Classification) |
- |
15000 |
|
- |
| 8 & 8.1.1(Ventilating Grill Gate (Inside)) |
- |
15000 |
|
- |
| 8.1.1.1(Locking device (unpickable dual control lock)) |
- |
15000 |
|
- |
| 8.1.2(Main Door- Outer & inner plate thickness) |
- |
15000 |
|
- |
| 8.1.2.1(Door(Finish &Gap of frame/edge with any place)) |
- |
15000 |
|
- |
| 8.2(Door frame (No.of barckets & Size for gripping)) |
- |
15000 |
|
- |
| 8.2.1(Rebate of the door frame) |
- |
15000 |
|
- |
| 8.2.2(Compression mechanism) |
- |
15000 |
|
- |
| 8.2.3(Crane hinge mechanism) |
- |
15000 |
|
- |
| 8.3(Lock case) |
- |
15000 |
|
- |
| 8.3.2(Bolt work) |
- |
15000 |
|
- |
| 8.3.2.2(Construction (of bolt work)) |
- |
15000 |
|
- |
| 8.3.2.3(Bearing piller) |
- |
15000 |
|
- |
| 8.4.1(Shooting bolt control (By lock)) |
- |
15000 |
|
- |
| 8.4.2(Test of key-Lock) |
- |
15000 |
|
- |
| 8.4.3(Lock fixing bolts) |
- |
15000 |
|
- |
| 8.4.4(Time lock) |
- |
15000 |
|
- |
| 8.4.5(Automatic Relocking devise) |
- |
15000 |
|
- |
| 9 &9.1(Hinges) |
- |
15000 |
|
- |
| 9.1.1(Adjusting bolt) |
- |
15000 |
|
- |
| 9.3(Foot bringe) |
- |
15000 |
|
- |
| 9.4(Vault lighting control) |
- |
15000 |
|
- |
| 10 &10.1(Dents,Burrs & Edges) |
- |
15000 |
|
- |
| 10.2(Colour coating thickness (Surafce paint)) |
- |
15000 |
|
- |
| 10.3(Cross Hatch test) |
- |
15000 |
|
- |
| 10.4(Door (Stainless cladding)) |
- |
15000 |
|
- |
| 11.1 &11.2(Test criteria for confomity -Burglaty attack) |
- |
15000 |
|
- |
| 11.1 &11.2(Test criteria for confomity -Fire resistancey) |
- |
15000 |
|
- |
| 12(Marking of door) |
- |
15000 |
|
- |
| 12.2(Marking on keys) |
- |
15000 |
|
- |
|
14 Nov, 2027 |
- Included w.e.f. 28.03.2025 |
| 4506 |
Atmy Analytical Labs Private Limited (Unit-2), Greater Noida
| 8176106
| IS 11188 : Part 1 (2021) |
Vault Strong Room doors Part 1 specification |
ALL |
349000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 11.1 (3)(Fire and stream hose IS 11188 (Part 3)) |
- |
349000 |
|
- |
| 11.1 (2)(Fire endurance IS 11188 (Part 3)) |
- |
349000 |
|
- |
| 11.1 (1)(Burglary resistance IS 11188 (Part 2)) |
- |
349000 |
|
- |
| 10.4(Alternate to Cl 10.4) |
- |
349000 |
|
- |
| 10.3(Cross Hatch Test) |
- |
349000 |
|
- |
| 10(FINISH) |
- |
349000 |
|
- |
| 9.4(Vault Lighting Control) |
- |
349000 |
|
- |
| 9.3(Foot Bridge) |
- |
349000 |
|
- |
| 9.2(Handles) |
- |
349000 |
|
- |
| 9.1.1(Adjusting Bolt) |
- |
349000 |
|
- |
| 9.1(Hinges) |
- |
349000 |
|
- |
| 9(DOOR FITTINGS) |
- |
349000 |
|
- |
| 8.4.5(Automatic Relocking Device) |
- |
349000 |
|
- |
| 8.4.4(Time Lock) |
- |
349000 |
|
- |
| 8.4(Lock) |
- |
349000 |
|
- |
| 8.3.2.2(Construction) |
- |
349000 |
|
- |
| 8.3.2.1(The number of bolts and their minimum dimension) |
- |
349000 |
|
- |
| 8.3.2(Bolt Work) |
- |
349000 |
|
- |
| 8.3.1(Lock Case) |
- |
349000 |
|
- |
| 8.3(Locking Mechanism) |
- |
349000 |
|
- |
| 8.2.3(Crane Hinge Mechanism) |
- |
349000 |
|
- |
| 8.2.2(Compression Mechanism) |
- |
349000 |
|
- |
| 8.2.1(Rebate of the Door Frame) |
- |
349000 |
|
- |
| 8.2(Doors Frame) |
- |
349000 |
|
- |
| 8.1.2(Main Door (Outside)) |
- |
349000 |
|
- |
| 8.1.1(Ventilating Grill Gate (Inside)) |
- |
349000 |
|
- |
| 8.1 Fig. 1(Doors) |
- |
349000 |
|
- |
| 8(CONSTRUCTION AND GENERALREQUIREMENTS) |
- |
349000 |
|
- |
| 5 Table 1(bolts, Min) |
- |
349000 |
|
- |
| 5 Table 1(xix) Depth of engagement of shooting) |
- |
349000 |
|
- |
| 5 Table 1(cross sectional area, Min,sq mm) |
- |
349000 |
|
- |
| 5 Table 1(xviii) Diameter of shooting bolts, Min) |
- |
349000 |
|
- |
| 5 Table 1(xvi) Number of shooting bolts at top,Min) |
- |
349000 |
|
- |
| 5 Table 1(xv) Number of shooting bolts on opposite side,Min) |
- |
349000 |
|
- |
| 5 Table 1(xiv) Number of shooting bolts on hinge side, Min) |
- |
349000 |
|
- |
| 5 Table 1(xiii) Number of locks) |
- |
349000 |
|
- |
| 5 Table 1(xii) Wall thickness (recommendation)) |
- |
349000 |
|
- |
| 5 Table 1(xi) Thickness of drill and oxyacetylene
torch resisting layer (excluding mild steel plates),Min) |
- |
349000 |
|
- |
| 5 Table 1(ix) Thickness of doors slab, thickness over rebate) |
- |
349000 |
|
- |
| 5 Table 1(viii) Pitch of grill gate rods) |
- |
349000 |
|
- |
| 5 Table 1(vii) Diameter of grill gate rods, Min) |
- |
349000 |
|
- |
| 5 Table 1(vi) Thickens of grill gate angles or
section made out of M.S. plates, Min) |
- |
349000 |
|
- |
| 5 Table 1(v) Dimension of the rebate coming under shear) |
- |
349000 |
|
- |
| 5 Table 1(iv (b) Thickness of door frame, if
fabricated from single plate to form
channel/multi-bend section, Min) |
- |
349000 |
|
- |
| 5 Table 1(ii (a) Height H, Min b) Width W, Min
iv(a) Thickness of door frame angle,
channel or section made out of M.S.
plates, if built up to form a channel,Min) |
- |
349000 |
|
- |
| 5 Table 1(iii) Inside dimension or clear opening when
door shutters are swung open at 180 degree) |
- |
349000 |
|
- |
| 5 Table 1(ii (b) Width W) |
- |
349000 |
|
- |
| 5 Table 1(ii (a) Height, H) |
- |
349000 |
|
- |
| 5 Table 1(ii) Overall dimension of vault door) |
- |
349000 |
|
- |
| 5 Table 1(i) Door Type) |
- |
349000 |
|
- |
| 4(Type) |
- |
349000 |
|
- |
| 5(Table-1)(Type of Door) |
- |
349000 |
|
- |
| 5(Table-1)(Overall dimesion of door) |
- |
349000 |
|
- |
| 5(Table-1)(Inside dimension or clear opening of door) |
- |
349000 |
|
- |
| 5(Table-1)(Thickness of door frame angle-made of Plate,if bulit up to form a channel) |
- |
349000 |
|
- |
| 5(Table-1)(Thickness of door frame ,if fabricated or multibend) |
- |
349000 |
|
- |
| 5(Table-1)(Dimension of the rebate coming under share) |
- |
349000 |
|
- |
| 5(Table-1)(Thickness of grill gate angle/section) |
- |
349000 |
|
- |
| 5(Table-1)(Diameter of grill gate rod) |
- |
349000 |
|
- |
| 5(Table-1)(Pitch of grill gate rod) |
- |
349000 |
|
- |
| 5(Table-1)(Thickness of door slab,thickness over rebate) |
- |
349000 |
|
- |
| 5(Table-1)(Thickness of the door over lock) |
- |
349000 |
|
- |
| 5(Table-1)(Thickness of drill & oxyacetylene torch resis. layer(exclue MS plate) |
- |
349000 |
|
- |
| 5(Table-1)(Wall thickness) |
- |
349000 |
|
- |
| 5(Table-1)(Number of locks) |
- |
349000 |
|
- |
| 5(Table-1)(Number of shooting bolys on hinge side) |
- |
349000 |
|
- |
| 5(Table-1)(Number of shooting bolts on opposite) |
- |
349000 |
|
- |
| 5(Table-1)(Number of shooting bolts at top) |
- |
349000 |
|
- |
| 5(Table-1)(Number of shooting bolts at bottom) |
- |
349000 |
|
- |
| 5(Table-1)(Cross sectional area as per shooting bolt) |
- |
349000 |
|
- |
| 5(Table-1)(Depth engagement of shooting) |
- |
349000 |
|
- |
| 6(Materail) |
- |
349000 |
|
- |
| 7(Classification) |
- |
349000 |
|
- |
| 8 & 8.1.1(Ventilating Grill Gate (Inside)) |
- |
349000 |
|
- |
| 8.1.1.1(Locking device (unpickable dual control lock)) |
- |
349000 |
|
- |
| 8.1.2(Main Door- Outer & inner plate thickness) |
- |
349000 |
|
- |
| 8.1.2.1(Door(Finish &Gap of frame/edge with any place)) |
- |
349000 |
|
- |
| 8.2(Door frame (No.of barckets & Size for gripping)) |
- |
349000 |
|
- |
| 8.2.1(Rebate of the door frame) |
- |
349000 |
|
- |
| 8.2.2(Compression mechanism) |
- |
349000 |
|
- |
| 8.2.3(Crane hinge mechanism) |
- |
349000 |
|
- |
| 8.3(Lock case) |
- |
349000 |
|
- |
| 8.3.2(Bolt work) |
- |
349000 |
|
- |
| 8.3.2.2(Construction (of bolt work)) |
- |
349000 |
|
- |
| 8.3.2.3(Bearing piller) |
- |
349000 |
|
- |
| 8.4.1(Shooting bolt control (By lock)) |
- |
349000 |
|
- |
| 8.4.2(Test of key-Lock) |
- |
349000 |
|
- |
| 8.4.3(Lock fixing bolts) |
- |
349000 |
|
- |
| 8.4.4(Time lock) |
- |
349000 |
|
- |
| 8.4.5(Automatic Relocking devise) |
- |
349000 |
|
- |
| 9 &9.1(Hinges) |
- |
349000 |
|
- |
| 9.1.1(Adjusting bolt) |
- |
349000 |
|
- |
| 9.2(Handles) |
- |
349000 |
|
- |
| 9.3(Foot bringe) |
- |
349000 |
|
- |
| 9.4(Vault lighting control) |
- |
349000 |
|
- |
| 10 &10.1(Dents,Burrs & Edges) |
- |
349000 |
|
- |
| 10.2(Colour coating thickness (Surafce paint)) |
- |
349000 |
|
- |
| 10.3(Cross Hatch test) |
- |
349000 |
|
- |
| 10.4(Door (Stainless cladding)) |
- |
349000 |
|
- |
| 11.1 &11.2(Test criteria for confomity -Burglaty attack) |
- |
349000 |
|
- |
| 11.1 &11.2(Test criteria for confomity -Fire resistancey) |
- |
349000 |
|
- |
| 12(Marking of door) |
- |
349000 |
|
- |
| 12.2(Marking on keys) |
- |
349000 |
|
- |
| 4(Type) |
- |
349000 |
|
- |
| 5(Table-1)(5(Table-1)) |
- |
349000 |
|
- |
| 5(Table-1)(Overall dimesion of door) |
- |
349000 |
|
- |
| 5(Table-1)(Inside dimension or clear opening of door) |
- |
349000 |
|
- |
| 5(Table-1)(Thickness of door frame angle-made of Plate,if bulit up to form a channel) |
- |
349000 |
|
- |
| 5(Table-1)(Thickness of door frame ,if fabricated or multibend) |
- |
349000 |
|
- |
| 5(Table-1)(Dimension of the rebate coming under share) |
- |
349000 |
|
- |
| 5(Table-1)(Thickness of grill gate angle/section) |
- |
349000 |
|
- |
| 5(Table-1)(Diameter of grill gate rod) |
- |
349000 |
|
- |
| 5(Table-1)(Pitch of grill gate rod) |
- |
349000 |
|
- |
| 5(Table-1)(Thickness of door slab,thickness over rebate) |
- |
349000 |
|
- |
| 5(Table-1)(Thickness of the door over lock) |
- |
349000 |
|
- |
| 5(Table-1)(Thickness of drill & oxyacetylene torch resis. layer(exclue MS plate) |
- |
349000 |
|
- |
| 5(Table-1)(Wall thickness) |
- |
349000 |
|
- |
| 5(Table-1)(Number of locks) |
- |
349000 |
|
- |
| 5(Table-1)(Number of shooting bolys on hinge side) |
- |
349000 |
|
- |
| 5(Table-1)(Number of shooting bolts at top) |
- |
349000 |
|
- |
| 5(Table-1)(Number of shooting bolts at bottom) |
- |
349000 |
|
- |
| 5(Table-1)(Cross sectional area as per shooting bolt) |
- |
349000 |
|
- |
| 5(Table-1)(Depth engagement of shooting) |
- |
349000 |
|
- |
| 6(Materail) |
- |
349000 |
|
- |
| 7(Classification) |
- |
349000 |
|
- |
| 8 & 8.1.1(Ventilating Grill Gate (Inside)) |
- |
349000 |
|
- |
| 8.1.1.1(Locking device (unpickable dual control lock)) |
- |
349000 |
|
- |
| 8.1.2(Main Door- Outer & inner plate thickness) |
- |
349000 |
|
- |
| 8.1.2.1(Door(Finish &Gap of frame/edge with any place)) |
- |
349000 |
|
- |
| 8.2(Door frame (No.of barckets & Size for gripping)) |
- |
349000 |
|
- |
| 8.2.1(Rebate of the door frame) |
- |
349000 |
|
- |
| 8.2.2(Compression mechanism) |
- |
349000 |
|
- |
| 8.2.3(Crane hinge mechanism) |
- |
349000 |
|
- |
| 8.3(Lock case) |
- |
349000 |
|
- |
| 8.3.2(Bolt work) |
- |
349000 |
|
- |
| 8.3.2.2(Construction (of bolt work)) |
- |
349000 |
|
- |
| 8.3.2.3(Bearing piller) |
- |
349000 |
|
- |
| 8.4.1(Shooting bolt control (By lock)) |
- |
349000 |
|
- |
| 8.4.2(Test of key-Lock) |
- |
349000 |
|
- |
| 8.4.3(Lock fixing bolts) |
- |
349000 |
|
- |
| 8.4.4(Time lock) |
- |
349000 |
|
- |
| 8.4.5(Automatic Relocking devise) |
- |
349000 |
|
- |
| 9 &9.1(Hinges) |
- |
349000 |
|
- |
| 9.1.1(Adjusting bolt) |
- |
349000 |
|
- |
| 9.3(Foot bringe) |
- |
349000 |
|
- |
| 9.4(Vault lighting control) |
- |
349000 |
|
- |
| 10 &10.1(Dents,Burrs & Edges) |
- |
349000 |
|
- |
| 10.2(Colour coating thickness (Surafce paint)) |
- |
349000 |
|
- |
| 10.3(Cross Hatch test) |
- |
349000 |
|
- |
| 10.4(Door (Stainless cladding)) |
- |
349000 |
|
- |
| 11.1 &11.2(Test criteria for confomity -Burglaty attack) |
- |
349000 |
|
- |
| 11.1 &11.2(Test criteria for confomity -Fire resistancey) |
- |
349000 |
|
- |
| 12(Marking of door) |
- |
349000 |
|
- |
| 12.2(Marking on keys) |
- |
349000 |
|
- |
|
08 Feb, 2027 |
- Included w.e.f. 01.04.2025 |
| 4507 |
Atmy Analytical Labs Private Limited (Unit-2), Greater Noida
| 8176106
| IS 5244 (2020) |
Safe Deposit Locker Cabinets — Specification ( Fourth Revision ) |
- |
39500 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl. 4.1( Types ) |
- |
0 |
|
- |
| Cl. 6 (Fig-5)(Cabinet Size (in mm)) |
- |
0 |
|
- |
| Table 1(Thickness Min. (in mm)) |
- |
0 |
|
- |
| Table 1(Thickness Min. (in mm)) |
- |
0 |
|
- |
| Table 1(Thickness Min. (in mm)) |
- |
0 |
|
- |
| Table 1(Thickness Min. (in mm)) |
- |
0 |
|
- |
| Table 1(Thickness Min. (in mm)) |
- |
0 |
|
- |
| Table 1(Thickness Min. (in mm)) |
- |
0 |
|
- |
| Table 1(Thickness Min. (in mm)) |
- |
0 |
|
- |
| Table 1(Thickness Min. (in mm)) |
- |
0 |
|
- |
| Table 1(Thickness Min. (in mm)) |
- |
0 |
|
- |
| Table 1(Thickness Min. (in mm)) |
- |
0 |
|
- |
| Table 1(Finish) |
- |
0 |
|
- |
| Table 1(Finish) |
- |
0 |
|
- |
| Cl.6(Sizes (Minimum Inside Measurements of locker) Locker Size) |
- |
0 |
|
- |
| Cl.6(Sizes (Minimum Inside Measurements of locker) Locker Size) |
- |
0 |
|
- |
| Cl.6(Sizes (Minimum Inside Measurements of locker) Locker Size) |
- |
0 |
|
- |
| Cl. 7.1(Design and Manufacture) |
- |
0 |
|
- |
| Cl. 7.1(Design and Manufacture) |
- |
0 |
|
- |
| Cl. 7.1(Design and Manufacture) |
- |
0 |
|
- |
| Cl. 7.1(Design and Manufacture) |
- |
0 |
|
- |
| Cl. 7.1(Design and Manufacture) |
- |
0 |
|
- |
| Cl. 7.2(Design and Manufacture) |
- |
0 |
|
- |
| Cl. 7.3(Design and Manufacture) |
- |
0 |
|
- |
| Cl. 7.3(Design and Manufacture) |
- |
0 |
|
- |
| Cl. 7.4(Design and Manufacture) |
- |
0 |
|
- |
| Cl. 7.5(Design and Manufacture) |
- |
0 |
|
- |
| Cl. 7.6(Design and Manufacture) |
- |
0 |
|
- |
| Cl. 8(Workmanship) |
- |
0 |
|
- |
| Cl. 8.2(Tolerance) |
- |
0 |
|
- |
| Cl. 9.1(Testing) |
- |
0 |
|
- |
| Cl. 9.2(Testing) |
- |
0 |
|
- |
| Cl. 9.3(Cross Hatch Test) |
- |
0 |
|
- |
| Cl. 10.1(Marking) |
- |
0 |
|
- |
| Cl. 10.2(Marking) |
- |
0 |
|
- |
| Cl. 10.3(Marking) |
- |
0 |
|
- |
| Cl. 10.4(Marking on Keys) |
- |
0 |
|
- |
| Cl. 11(Packing) |
- |
0 |
|
- |
|
08 Feb, 2027 |
- Included w.e.f. 01.04.2025 |
| 4508 |
URS PRODUCTS AND TESTING PVT. LTD. (A29), NOIDA
| 8168906
| IS 2347 (2017) |
Domestic pressure cooker - Specification (Sixth Revision) |
- |
34000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4.1(Capacity) |
- |
400 |
|
- |
| 5.1.1(Body, Lid, Containers and Grid) |
- |
300 |
|
- |
| 5.1.2(Body, Lid, Containers and Grid) |
- |
300 |
|
- |
| 5.1.3(Body, Lid, Containers and Grid) |
- |
300 |
|
- |
| 5.1.4(Body, Lid, Containers and Grid) |
- |
300 |
|
- |
| 5.2(Safety Relief Device) |
- |
300 |
|
- |
| 5.3(Gasket) |
- |
300 |
|
- |
| 5.4(Handles and Knobs) |
- |
300 |
|
- |
| 5.5(Pressure Regulating Device) |
- |
300 |
|
- |
| 5.6(Vent Seal Pin for Pressure Regulating Device) |
- |
300 |
|
- |
| 5.7(Vent Pipe) |
- |
300 |
|
- |
| 5.8(Vent Pipe Nut) |
- |
300 |
|
- |
| 5.9(Spring) |
- |
300 |
|
- |
| 6(CONSTRUCTION) |
- |
300 |
|
- |
| 6.1(Pressure Regulating Device) |
- |
300 |
|
- |
| 6.1.1(Pressure Regulating Device) |
- |
300 |
|
- |
| 6.1.2(Pressure Regulating Device) |
- |
300 |
|
- |
| 6.1.3(Pressure Regulating Device) |
- |
300 |
|
- |
| 6.1.4(Pressure Regulating Device) |
- |
300 |
|
- |
| 6.1.5(Pressure Regulating Device) |
- |
300 |
|
- |
| 6.2(Safety Relief Device) |
- |
300 |
|
- |
| 6.2.1(Safety Relief Device) |
- |
300 |
|
- |
| 6.2.2(Safety Relief Device) |
- |
300 |
|
- |
| 6.3.1(Temperature Responsive Pressure Relief Device) |
- |
400 |
|
- |
| 6.3.1(Temperature Responsive Pressure Relief Device) |
- |
4000 |
|
- |
| 6.4.1(Handles and Knobs) |
- |
300 |
|
- |
| 6.4.1.1(Handles and Knobs) |
- |
300 |
|
- |
| 7.1(WORKMANSHIP AND FINISH) |
- |
300 |
|
- |
| 7.2(WORKMANSHIP AND FINISH) |
- |
300 |
|
- |
| 7.3(WORKMANSHIP AND FINISH) |
- |
500 |
|
- |
| 7.4(WORKMANSHIP AND FINISH) |
- |
1000 |
|
- |
| 8.1(Air Pressure Test) |
- |
600 |
|
- |
| 8.2(Proof Pressure Test) |
- |
600 |
|
- |
| 8.3(Operating Test for Pressure Regulating Device) |
- |
800 |
|
- |
| 8.4(Test for Safety Pressure Relief Device) |
- |
800 |
|
- |
| 8.5(Bursting Pressure Test) |
- |
1000 |
|
- |
| 8.6.1(Tests for Removal of Lid under Pressure For Outer Lid Cooker) |
- |
900 |
|
- |
| 8.6.2(Tests for Removal of Lid under Pressure For inner Lid Cooker) |
- |
900 |
|
- |
| 8.7(Test for Spring Loaded Mechanism) |
- |
800 |
|
- |
| 8.8(Test for Spring Loaded Mechanism) |
- |
1200 |
|
- |
| 8.9(Test for Spring Loaded Mechanism) |
- |
1200 |
|
- |
| 8.1(testing of handles of the cooker) |
- |
1200 |
|
- |
| 8.4 Annex H-1.2(Test for SPRD - For Resettable Devices ) |
- |
800 |
|
- |
| 8.4 Annex H-1.1(Test for SPRD - For Destructible Devices ) |
- |
800 |
|
- |
| 8.10 (a)(Handles of the cooker- Resistance to Burning) |
- |
700 |
|
- |
| 8.10 (b)(Handles of the cooker- Heat Resistance) |
- |
700 |
|
- |
| 8.10 (c)(Handles of the cooker- Torque Strength) |
- |
700 |
|
- |
| 8.10 (d)(Handles of the cooker- Bending Strength) |
- |
700 |
|
- |
| 8.10 (e)(Handles of the cooker- Fatigue Resistance) |
- |
1200 |
|
- |
| 8.10 (f)(Handles of the cooker- Thermal Insualtion Test) |
- |
800 |
|
- |
| 8.10 NOTES (3)(Handles of the cooker - Proof Pressure) |
- |
300 |
|
- |
| 8.10 NOTES (4)(Handles of the cooker) |
- |
300 |
|
- |
| 8.10 NOTES (5)(Handles of the cooker) |
- |
300 |
|
- |
| 8.10 NOTES (6)(Handles of the cooker) |
- |
300 |
|
- |
| 8.11.1 (a)(External Coating (powder coating or ceramic coating or high temperature resistant liquid coating)) |
- |
800 |
|
- |
| 8.11.1 (b)(External Coating (powder coating or ceramic coating or high temperature resistant liquid coating)) |
- |
800 |
|
- |
| 8.11.1 (c)(External Coating (powder coating or ceramic coating or high temperature resistant liquid coating)) |
- |
800 |
|
- |
| 8.11.1.1 (Thermal shock test for externally coated cooker) |
- |
1200 |
|
- |
| 8.12(Internal Coating) |
- |
1300 |
|
- |
| 8.14(3 Ply Construction Cooker Body) |
- |
1000 |
|
- |
| 11(Marking) |
- |
300 |
|
- |
|
26 Sep, 2027 |
- - |
| 4509 |
URS PRODUCTS AND TESTING PVT. LTD. (A29), NOIDA
| 8168906
| IS 14756 (2022) |
Draft Indian Standard STAINLESS STEEL COOKWARE SPECIFICATION Second Revision of IS 14756 |
- |
12000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 3.1(Material) |
- |
500 |
|
- |
| 3.2(Material) |
- |
500 |
|
- |
| 3.3(Material) |
- |
500 |
|
- |
| 3.4(Material) |
- |
500 |
|
- |
| 3.5(Material) |
- |
500 |
|
- |
| 4.1 (Annex A)(Shapes and Dimensions) |
- |
500 |
|
- |
| 4.2 (Table 1)(Shapes and Dimensions) |
- |
500 |
|
- |
| 4.3(Shapes and Dimensions) |
- |
500 |
|
- |
| 4.4(Shapes and Dimensions) |
- |
500 |
|
- |
| 6.1(Staining Test) |
- |
1000 |
|
- |
| 6.2(Mechanical Shock Test (For Cladded Utensils only)) |
- |
1000 |
|
- |
| 6.3(Thermal Shock Test (For Cladded Utensils only)) |
- |
1000 |
|
- |
| 6.4(Dry Heat Test (For Cladded Utensils only)) |
- |
1500 |
|
- |
| 6.5(Coating Thickness Test (For Copper Deposit)) |
- |
1000 |
|
- |
| 6.6(3 Ply) |
- |
1000 |
|
- |
| 6.7.1(Nominal Capacity Test) |
- |
1000 |
|
- |
| 6.8.1(Tests on Tempered Glass Lid) |
- |
1000 |
|
- |
| 6.8.2(Tests on Tempered Glass Lid (Ball drop test)) |
- |
1000 |
|
- |
| 6.8.3(Tests on Tempered Glass Lid (thermal shock test)) |
- |
1000 |
|
- |
| 6.8.4.1(Tests on Tempered Glass Lid (Free Fall Test with rim facing down)) |
- |
1000 |
|
- |
| 6.8.4.2(Tests on Tempered Glass Lid (Free Fall Test without rim facing down)) |
- |
1000 |
|
- |
| 3.4(Material) |
- |
500 |
|
- |
| 3.5(Material) |
- |
500 |
|
- |
| 3.5(Material) |
- |
500 |
|
- |
| 3.5(Material) |
- |
500 |
|
- |
| 4.2 (Table 1)(Shapes and Dimensions) |
- |
500 |
|
- |
| 4.2(Shapes and Dimensions) |
- |
500 |
|
- |
| 5.1(Workmanship and Finish) |
- |
500 |
|
- |
| 5.1(Workmanship and Finish) |
- |
500 |
|
- |
| 5.1(Workmanship and Finish) |
- |
500 |
|
- |
| 5.2(Workmanship and Finish) |
- |
500 |
|
- |
| 5.3(Workmanship and Finish) |
- |
500 |
|
- |
| 5.3(Workmanship and Finish) |
- |
500 |
|
- |
| 5.3(Workmanship and Finish) |
- |
500 |
|
- |
| 5.3(Workmanship and Finish) |
- |
500 |
|
- |
| 5.3(Workmanship and Finish) |
- |
500 |
|
- |
| 5.3(Workmanship and Finish) |
- |
500 |
|
- |
| 5.4(Workmanship and Finish) |
- |
500 |
|
- |
| 5.5(Workmanship and Finish) |
- |
500 |
|
- |
| 5.6(Workmanship and Finish) |
- |
500 |
|
- |
| 6.1(Staining Test) |
- |
1000 |
|
- |
| 6.7.2(Nominal Capacity Test- Diameter) |
- |
1000 |
|
- |
| 6.8.1(Tests on Tempered Glass Lid) |
- |
1000 |
|
- |
|
26 Sep, 2027 |
- - |
| 4510 |
Ace Test Labs & Metrology Pvt. Ltd., Sonipat
| 9162826
| IS 550 : Part 1 (2022) |
Safes: Part 1 specification Fifth Revision |
- |
258000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4(Classification) |
- |
124999.97 |
|
- |
| 5.1(Dimensions) |
- |
10000 |
|
- |
| 5.2(Sizes) |
- |
10000 |
|
- |
| 5.2(Table-2)(Inside dimensions) |
- |
10000 |
|
- |
| 5.2(Table-2)(Tolerance on inside dimensions) |
- |
10000 |
|
- |
| 5.2(Table-2)(Internal volume) |
- |
10000 |
|
- |
| 5.2(Table-2)(Tolerance on interanal volume) |
- |
10000 |
|
- |
| 5.2(Table-2)(Minumum Weight) |
- |
10000 |
|
- |
| 5.2(Table-2)(Thickness of Plates (outer bodys& Door)) |
- |
10000 |
|
- |
| 5.2(Table-2)(Thickness of Door slab) |
- |
10000 |
|
- |
| 5.2(Table-2)(Thickness of door overbolt work) |
- |
10000 |
|
- |
| 5.2(Table-2)(Number of lock on the door) |
- |
10000 |
|
- |
| 5.2(Table-2)(Any other type of lock) |
- |
10000 |
|
- |
| 5.2(Table-2)(Number of bolt on hinge side) |
- |
10000 |
|
- |
| 5.2(Table-2)(Number of bolt on opposite hinge) |
- |
10000 |
|
- |
| 5.2(Table-2)(No.of bolt at the top) |
- |
10000 |
|
- |
| 5.2(Table-2)(No.of bolt at the bottom) |
- |
10000 |
|
- |
| 5.2(Table-2)(Size of each bolt (area of bolt section)) |
- |
10000 |
|
- |
| 5.2(Table-2)(Depth engagement of bolt) |
- |
10000 |
|
- |
| 6(Material declaration) |
- |
10000 |
|
- |
| 7(Desigantion-Delaration) |
- |
10000 |
|
- |
| 8.1(Body (Construction & workmanship)) |
- |
10000 |
|
- |
| 8.2(Door (Gap)) |
- |
10000 |
|
- |
| 8.4.1(Hinges) |
- |
10000 |
|
- |
| 8.4.2(Bolts) |
- |
10000 |
|
- |
| 8.5(Handle) |
- |
10000 |
|
- |
| 8.6.1(Lock (key type) Garde) |
- |
10000 |
|
- |
| 8.6.1(Lock (key type)classification) |
- |
10000 |
|
- |
| 8.6.1(Lock (key type)construction) |
- |
10000 |
|
- |
| 8.6.1(Lock(key type) leaver thickness) |
- |
10000 |
|
- |
| 8.6.1(Lock (key type)Material) |
- |
10000 |
|
- |
| 8.6.1(Lock (key type)corrosion protection materail) |
- |
10000 |
|
- |
| 8.6.1(Lock(key type) -Endurance test) |
- |
10000 |
|
- |
| 8.6.1(Lock(key type)-Bolt forcing test) |
- |
10000 |
|
- |
| 8.6.1(Lock(key type)-salt spray solution test) |
- |
10000 |
|
- |
| 8.6.1(Lock(key type)-key strength test) |
- |
10000 |
|
- |
| 8.6.1(Lock(key type) -Marking) |
- |
10000 |
|
- |
| 8.6.1(Lock(Key type) -Key Marking) |
- |
10000 |
|
- |
| 8.6.1(Mechanical combination lock -Classification) |
- |
10000 |
|
- |
| 8.6.1(Mechanical combination lock -Construction) |
- |
10000 |
|
- |
| 8.6.1(Mechanical combination lock -Metallic parts) |
- |
10000 |
|
- |
| 8.6.1(Mechanical combination lock -Corrosion Prot) |
- |
10000 |
|
- |
| 8.6.1(Mechanical combination lock -Operation test) |
- |
10000 |
|
- |
| 8.6.1(Mechanical cmbination lock -Manipulation) |
- |
10000 |
|
- |
| 8.6.1(Mechanical combination lock -Punching attack) |
- |
10000 |
|
- |
| 8.6.1(Mechanical combination lock -Endurance test) |
- |
10000 |
|
- |
| 8.6.1(Mechanical combination lock-Salt spary test) |
- |
10000 |
|
- |
| 8.6.1(Mechanical combination lock-Strength test) |
- |
10000 |
|
- |
| 8.6.1(Mechanical combination lock-Aging-stress Dist) |
- |
10000 |
|
- |
| 8.6.1(Mechanical combination lock-Moisture Absorp) |
- |
10000 |
|
- |
| 8.6.1(Mechanical combination lock-Vibration test) |
- |
10000 |
|
- |
| 8.6.1(Mechanical combination lock-Marking) |
- |
10000 |
|
- |
| 8.6.1(Any other lock) |
- |
10000 |
|
- |
| 8.6.4(Lock Bolt engagement) |
- |
10000 |
|
- |
| 8.6.5(Additional provision- retrofitting time lock) |
- |
10000 |
|
- |
| 8.7(Automatic re-locking device) |
- |
10000 |
|
- |
| 8.8(Cable hole size) |
- |
10000 |
|
- |
| 9(Internal fixture) |
- |
10000 |
|
- |
| 10(Painting) |
- |
10000 |
|
- |
| 10.1(Cross hatch test) |
- |
10000 |
|
- |
| 11.1(Marking of safe) |
- |
10000 |
|
- |
| 12(Burglary attack) |
- |
99999.97 |
|
- |
| 12(Fire Resistance) |
- |
150000 |
|
- |
| 4(Classification) |
- |
100000 |
|
- |
| 5.1(Dimensions) |
- |
10000 |
|
- |
| 5.2(Sizes) |
- |
10000 |
|
- |
| 5.2(Table-2)(Inside dimensions) |
- |
10000 |
|
- |
| 5.2(Table-2)(Tolerance on inside dimensions) |
- |
10000 |
|
- |
| 5.2(Table-2)(Internal volume) |
- |
10000 |
|
- |
| 5.2(Table-2)(Tolerance on interanal volume) |
- |
10000 |
|
- |
| 5.2(Table-2)(Minumum Weight) |
- |
10000 |
|
- |
| 5.2(Table-2)(Thickness of Plates (outer bodys& Door)) |
- |
10000 |
|
- |
| 5.2(Table-2)(Thickness of Door slab) |
- |
10000 |
|
- |
| 5.2(Table-2)(Thickness of door overbolt work) |
- |
10000 |
|
- |
| 5.2(Table-2)(Number of lock on the door) |
- |
10000 |
|
- |
| 5.2(Table-2)(Any other type of lock) |
- |
10000 |
|
- |
| 5.2(Table-2)(Number of bolt on hinge side) |
- |
10000 |
|
- |
| 5.2(Table-2)(Number of bolt on opposite hinge) |
- |
10000 |
|
- |
| 5.2(Table-2)(No.of bolt at the top) |
- |
10000 |
|
- |
| 5.2(Table-2)(No.of bolt at the bottom) |
- |
10000 |
|
- |
| 5.2(Table-2)(Size of each bolt (area of bolt section)) |
- |
10000 |
|
- |
| 5.2(Table-2)(Depth engagement of bolt) |
- |
10000 |
|
- |
| 6(Material declaration) |
- |
10000 |
|
- |
| 7(Desigantion-Delaration) |
- |
10000 |
|
- |
| 8.1(Body (Construction & workmanship)) |
- |
10000 |
|
- |
| 8.2(Door (Gap)) |
- |
10000 |
|
- |
| 8.4.1(Hinges) |
- |
10000 |
|
- |
| 8.4.2(Bolts) |
- |
10000 |
|
- |
| 8.5(Handle) |
- |
10000 |
|
- |
| 8.6.1(Lock (key type) Garde) |
- |
10000 |
|
- |
| 8.6.1(Lock (key type)classification) |
- |
10000 |
|
- |
| 8.6.1(Lock (key type)construction) |
- |
10000 |
|
- |
| 8.6.1(Lock(key type) leaver thickness) |
- |
10000 |
|
- |
| 8.6.1(Lock (key type)Material) |
- |
10000 |
|
- |
| 8.6.1(Lock (key type)corrosion protection materail) |
- |
10000 |
|
- |
| 8.6.1(Lock(key type) -Endurance test) |
- |
10000 |
|
- |
| 8.6.1(Lock(key type)-Bolt forcing test) |
- |
10000 |
|
- |
| 8.6.1(Lock(key type)-salt spray solution test) |
- |
10000 |
|
- |
| 8.6.1(Lock(key type)-key strength test) |
- |
10000 |
|
- |
| 8.6.1(Lock(key type) -Marking) |
- |
10000 |
|
- |
| 8.6.1(Lock(Key type) -Key Marking) |
- |
10000 |
|
- |
| 8.6.1(Mechanical combination lock -Classification) |
- |
10000 |
|
- |
| 8.6.1(Mechanical combination lock -Construction) |
- |
10000 |
|
- |
| 8.6.1(Mechanical combination lock -Metallic parts) |
- |
10000 |
|
- |
| 8.6.1(Mechanical combination lock -Corrosion Prot) |
- |
10000 |
|
- |
| 8.6.1(Mechanical combination lock -Operation test) |
- |
10000 |
|
- |
| 8.6.1(Mechanical cmbination lock -Manipulation) |
- |
10000 |
|
- |
| 8.6.1(Mechanical combination lock -Punching attack) |
- |
10000 |
|
- |
| 8.6.1(Mechanical combination lock -Endurance test) |
- |
10000 |
|
- |
| 8.6.1(Mechanical combination lock-Salt spary test) |
- |
10000 |
|
- |
| 8.6.1(Mechanical combination lock-Strength test) |
- |
10000 |
|
- |
| 8.6.1(Mechanical combination lock-Aging-stress Dist) |
- |
10000 |
|
- |
| 8.6.1(Mechanical combination lock-Moisture Absorp) |
- |
10000 |
|
- |
| 8.6.1(Mechanical combination lock-Vibration test) |
- |
10000 |
|
- |
| 8.6.1(Mechanical combination lock-Marking) |
- |
10000 |
|
- |
| 8.6.1(Any other lock) |
- |
10000 |
|
- |
| 8.6.4(Lock Bolt engagement) |
- |
10000 |
|
- |
| 8.6.5(Additional provision- retrofitting time lock) |
- |
10000 |
|
- |
| 8.7(Automatic re-locking device) |
- |
10000 |
|
- |
| 8.8(Cable hole size) |
- |
10000 |
|
- |
| 9(Internal fixture) |
- |
10000 |
|
- |
| 10(Painting) |
- |
10000 |
|
- |
| 10.1(Cross hatch test) |
- |
10000 |
|
- |
| 11.1(Marking of safe) |
- |
10000 |
|
- |
| 12(Burglary attack) |
- |
100000 |
|
- |
| 12(Fire Resistance) |
- |
150000 |
|
- |
|
14 Nov, 2027 |
- Included w.e.f. 28.03.2025 |
| 4511 |
Atmy Analytical Labs Private Limited (Unit-2), Greater Noida
| 8176106
| IS 17541 (2021) |
Modular panel for security of premises specification |
- |
546000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Clause-5(Dimensions) |
- |
0 |
|
- |
| Clause-6(Materials) |
- |
0 |
|
- |
| Clause-8(Construction and General Requirements) |
- |
0 |
|
- |
| Clause-9(Fittings) |
- |
0 |
|
- |
| Clause-10(Finish) |
- |
0 |
|
- |
| Clause-10.1(Cross Hatch Test) |
- |
0 |
|
- |
| Clause-11.2, 1(Full length panel (Continuous design panel)) |
- |
0 |
|
- |
| Clause-11.2, 2(Assemble panel/Segmented panel) |
- |
0 |
|
- |
| Clause-12(Marking) |
- |
0 |
|
- |
| Clause-5(Dimensions) |
- |
0 |
|
- |
| Clause-6(Materials) |
- |
0 |
|
- |
| Clause-8(Construction and General Requirements) |
- |
0 |
|
- |
| Clause-9(Fittings) |
- |
0 |
|
- |
| Clause-10(Finish) |
- |
0 |
|
- |
| Clause-10.1(Cross Hatch Test) |
- |
0 |
|
- |
| Clause-11.2, 1(Full length panel (Continuous design panel)) |
- |
0 |
|
- |
| Clause-11.2, 2(Assemble panel/Segmented panel) |
- |
0 |
|
- |
| Clause-12(Marking) |
- |
0 |
|
- |
|
08 Feb, 2027 |
- Included w.e.f. 01.04.2025 |
| 4512 |
Atmy Analytical Labs Private Limited (Unit-2), Greater Noida
| 8176106
| IS 550 : Part 1 (2022) |
Safes: Part 1 specification Fifth Revision |
- |
380000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4(Classification) |
- |
0 |
|
- |
| 5.1(Dimensions) |
- |
0 |
|
- |
| 5.2(Sizes) |
- |
0 |
|
- |
| 5.2(Table-2)(Inside dimensions) |
- |
0 |
|
- |
| 5.2(Table-2)(Tolerance on inside dimensions) |
- |
0 |
|
- |
| 5.2(Table-2)(Internal volume) |
- |
0 |
|
- |
| 5.2(Table-2)(Tolerance on interanal volume) |
- |
0 |
|
- |
| 5.2(Table-2)(Minumum Weight) |
- |
0 |
|
- |
| 5.2(Table-2)(Thickness of Plates (outer bodys& Door)) |
- |
0 |
|
- |
| 5.2(Table-2)(Thickness of Door slab) |
- |
0 |
|
- |
| 5.2(Table-2)(Thickness of door overbolt work) |
- |
0 |
|
- |
| 5.2(Table-2)(Number of lock on the door) |
- |
0 |
|
- |
| 5.2(Table-2)(Any other type of lock) |
- |
0 |
|
- |
| 5.2(Table-2)(Number of bolt on hinge side) |
- |
0 |
|
- |
| 5.2(Table-2)(Number of bolt on opposite hinge) |
- |
0 |
|
- |
| 5.2(Table-2)(No.of bolt at the top) |
- |
0 |
|
- |
| 5.2(Table-2)(No.of bolt at the bottom) |
- |
0 |
|
- |
| 5.2(Table-2)(Size of each bolt (area of bolt section)) |
- |
0 |
|
- |
| 5.2(Table-2)(Depth engagement of bolt) |
- |
0 |
|
- |
| 6(Material declaration) |
- |
0 |
|
- |
| 7(Desigantion-Delaration) |
- |
0 |
|
- |
| 8.1(Body (Construction & workmanship)) |
- |
0 |
|
- |
| 8.2(Door (Gap)) |
- |
0 |
|
- |
| 8.4.1(Hinges) |
- |
0 |
|
- |
| 8.4.2(Bolts) |
- |
0 |
|
- |
| 8.5(Handle) |
- |
0 |
|
- |
| 8.6.1(Lock (key type) Garde) |
- |
0 |
|
- |
| 8.6.1(Lock (key type)classification) |
- |
0 |
|
- |
| 8.6.1(Lock (key type)construction) |
- |
0 |
|
- |
| 8.6.1(Lock(key type) leaver thickness) |
- |
0 |
|
- |
| 8.6.1(Lock (key type)Material) |
- |
0 |
|
- |
| 8.6.1(Lock (key type)corrosion protection materail) |
- |
0 |
|
- |
| 8.6.1(Lock(key type) -Endurance test) |
- |
0 |
|
- |
| 8.6.1(Lock(key type)-Bolt forcing test) |
- |
0 |
|
- |
| 8.6.1(Lock(key type)-salt spray solution test) |
- |
0 |
|
- |
| 8.6.1(Lock(key type)-key strength test) |
- |
0 |
|
- |
| 8.6.1(Lock(key type) -Marking) |
- |
0 |
|
- |
| 8.6.1(Lock(Key type) -Key Marking) |
- |
0 |
|
- |
| 8.6.1(Mechanical combination lock -Classification) |
- |
0 |
|
- |
| 8.6.1(Mechanical combination lock -Construction) |
- |
0 |
|
- |
| 8.6.1(Mechanical combination lock -Metallic parts) |
- |
0 |
|
- |
| 8.6.1(Mechanical combination lock -Corrosion Prot) |
- |
0 |
|
- |
| 8.6.1(Mechanical combination lock -Operation test) |
- |
0 |
|
- |
| 8.6.1(Mechanical cmbination lock -Manipulation) |
- |
0 |
|
- |
| 8.6.1(Mechanical combination lock -Punching attack) |
- |
0 |
|
- |
| 8.6.1(Mechanical combination lock -Endurance test) |
- |
0 |
|
- |
| 8.6.1(Mechanical combination lock-Salt spary test) |
- |
0 |
|
- |
| 8.6.1(Mechanical combination lock-Strength test) |
- |
0 |
|
- |
| 8.6.1(Mechanical combination lock-Aging-stress Dist) |
- |
0 |
|
- |
| 8.6.1(Mechanical combination lock-Moisture Absorp) |
- |
0 |
|
- |
| 8.6.1(Mechanical combination lock-Vibration test) |
- |
0 |
|
- |
| 8.6.1(Mechanical combination lock-Marking) |
- |
0 |
|
- |
| 8.6.1(Any other lock) |
- |
0 |
|
- |
| 8.6.4(Lock Bolt engagement) |
- |
0 |
|
- |
| 8.6.5(Additional provision- retrofitting time lock) |
- |
0 |
|
- |
| 8.7(Automatic re-locking device) |
- |
0 |
|
- |
| 8.8(Cable hole size) |
- |
0 |
|
- |
| 9(Internal fixture) |
- |
0 |
|
- |
| 10(Painting) |
- |
0 |
|
- |
| 10.1(Cross hatch test) |
- |
0 |
|
- |
| 11.1(Marking of safe) |
- |
0 |
|
- |
| 12(Burglary attack) |
- |
0 |
|
- |
| 12(Fire Resistance) |
- |
0 |
|
- |
| 4(Classification) |
- |
0 |
|
- |
| 5.1(Dimensions) |
- |
0 |
|
- |
| 5.2(Sizes) |
- |
0 |
|
- |
| 5.2(Table-2)(Inside dimensions) |
- |
0 |
|
- |
| 5.2(Table-2)(Tolerance on inside dimensions) |
- |
0 |
|
- |
| 5.2(Table-2)(Internal volume) |
- |
0 |
|
- |
| 5.2(Table-2)(Tolerance on interanal volume) |
- |
0 |
|
- |
| 5.2(Table-2)(Minumum Weight) |
- |
0 |
|
- |
| 5.2(Table-2)(Thickness of Plates (outer bodys& Door)) |
- |
0 |
|
- |
| 5.2(Table-2)(Thickness of Door slab) |
- |
0 |
|
- |
| 5.2(Table-2)(Thickness of door overbolt work) |
- |
0 |
|
- |
| 5.2(Table-2)(Number of lock on the door) |
- |
0 |
|
- |
| 5.2(Table-2)(Any other type of lock) |
- |
0 |
|
- |
| 5.2(Table-2)(Number of bolt on hinge side) |
- |
0 |
|
- |
| 5.2(Table-2)(Number of bolt on opposite hinge) |
- |
0 |
|
- |
| 5.2(Table-2)(No.of bolt at the top) |
- |
0 |
|
- |
| 5.2(Table-2)(No.of bolt at the bottom) |
- |
0 |
|
- |
| 5.2(Table-2)(Size of each bolt (area of bolt section)) |
- |
0 |
|
- |
| 5.2(Table-2)(Depth engagement of bolt) |
- |
0 |
|
- |
| 6(Material declaration) |
- |
0 |
|
- |
| 7(Desigantion-Delaration) |
- |
0 |
|
- |
| 8.1(Body (Construction & workmanship)) |
- |
0 |
|
- |
| 8.2(Door (Gap)) |
- |
0 |
|
- |
| 8.4.1(Hinges) |
- |
0 |
|
- |
| 8.4.2(Bolts) |
- |
0 |
|
- |
| 8.5(Handle) |
- |
0 |
|
- |
| 8.6.1(Lock (key type) Garde) |
- |
0 |
|
- |
| 8.6.1(Lock (key type)classification) |
- |
0 |
|
- |
| 8.6.1(Lock (key type)construction) |
- |
0 |
|
- |
| 8.6.1(Lock(key type) leaver thickness) |
- |
0 |
|
- |
| 8.6.1(Lock (key type)Material) |
- |
0 |
|
- |
| 8.6.1(Lock (key type)corrosion protection materail) |
- |
0 |
|
- |
| 8.6.1(Lock(key type) -Endurance test) |
- |
0 |
|
- |
| 8.6.1(Lock(key type)-Bolt forcing test) |
- |
0 |
|
- |
| 8.6.1(Lock(key type)-salt spray solution test) |
- |
0 |
|
- |
| 8.6.1(Lock(key type)-key strength test) |
- |
0 |
|
- |
| 8.6.1(Lock(key type) -Marking) |
- |
0 |
|
- |
| 8.6.1(Lock(Key type) -Key Marking) |
- |
0 |
|
- |
| 8.6.1(Mechanical combination lock -Classification) |
- |
0 |
|
- |
| 8.6.1(Mechanical combination lock -Construction) |
- |
0 |
|
- |
| 8.6.1(Mechanical combination lock -Metallic parts) |
- |
0 |
|
- |
| 8.6.1(Mechanical combination lock -Corrosion Prot) |
- |
0 |
|
- |
| 8.6.1(Mechanical combination lock -Operation test) |
- |
0 |
|
- |
| 8.6.1(Mechanical cmbination lock -Manipulation) |
- |
0 |
|
- |
| 8.6.1(Mechanical combination lock -Punching attack) |
- |
0 |
|
- |
| 8.6.1(Mechanical combination lock -Endurance test) |
- |
0 |
|
- |
| 8.6.1(Mechanical combination lock-Salt spary test) |
- |
0 |
|
- |
| 8.6.1(Mechanical combination lock-Strength test) |
- |
0 |
|
- |
| 8.6.1(Mechanical combination lock-Aging-stress Dist) |
- |
0 |
|
- |
| 8.6.1(Mechanical combination lock-Moisture Absorp) |
- |
0 |
|
- |
| 8.6.1(Mechanical combination lock-Vibration test) |
- |
0 |
|
- |
| 8.6.1(Mechanical combination lock-Marking) |
- |
0 |
|
- |
| 8.6.1(Any other lock) |
- |
0 |
|
- |
| 8.6.4(Lock Bolt engagement) |
- |
0 |
|
- |
| 8.6.5(Additional provision- retrofitting time lock) |
- |
0 |
|
- |
| 8.7(Automatic re-locking device) |
- |
0 |
|
- |
| 8.8(Cable hole size) |
- |
0 |
|
- |
| 9(Internal fixture) |
- |
0 |
|
- |
| 10(Painting) |
- |
0 |
|
- |
| 10.1(Cross hatch test) |
- |
0 |
|
- |
| 11.1(Marking of safe) |
- |
0 |
|
- |
| 12(Burglary attack) |
- |
0 |
|
- |
| 12(Fire Resistance) |
- |
0 |
|
- |
| 4(Classification) |
- |
0 |
|
- |
| 5.1(Dimensions) |
- |
0 |
|
- |
| 5.2(Sizes) |
- |
0 |
|
- |
| 5.2(Table-2)(Inside dimensions) |
- |
0 |
|
- |
| 5.2(Table-2)(Tolerance on inside dimensions) |
- |
0 |
|
- |
| 5.2(Table-2)(Internal volume) |
- |
0 |
|
- |
| 5.2(Table-2)(Tolerance on interanal volume) |
- |
0 |
|
- |
| 5.2(Table-2)(Minumum Weight) |
- |
0 |
|
- |
| 5.2(Table-2)(Thickness of Plates (outer bodys& Door)) |
- |
0 |
|
- |
| 5.2(Table-2)(Thickness of Door slab) |
- |
0 |
|
- |
| 5.2(Table-2)(Thickness of door overbolt work) |
- |
0 |
|
- |
| 5.2(Table-2)(Number of lock on the door) |
- |
0 |
|
- |
| 5.2(Table-2)(Any other type of lock) |
- |
0 |
|
- |
| 5.2(Table-2)(Number of bolt on hinge side) |
- |
0 |
|
- |
| 5.2(Table-2)(Number of bolt on opposite hinge) |
- |
0 |
|
- |
| 5.2(Table-2)(No.of bolt at the top) |
- |
0 |
|
- |
| 5.2(Table-2)(No.of bolt at the bottom) |
- |
0 |
|
- |
| 5.2(Table-2)(Size of each bolt (area of bolt section)) |
- |
0 |
|
- |
| 5.2(Table-2)(Depth engagement of bolt) |
- |
0 |
|
- |
| 6(Material declaration) |
- |
0 |
|
- |
| 7(Desigantion-Delaration) |
- |
0 |
|
- |
| 8.1(Body (Construction & workmanship)) |
- |
0 |
|
- |
| 8.2(Door (Gap)) |
- |
0 |
|
- |
| 8.4.1(Hinges) |
- |
0 |
|
- |
| 8.4.2(Bolts) |
- |
0 |
|
- |
| 8.5(Handle) |
- |
0 |
|
- |
| 8.6.1(Lock (key type) Garde) |
- |
0 |
|
- |
| 8.6.1(Lock (key type)classification) |
- |
0 |
|
- |
| 8.6.1(Lock (key type)construction) |
- |
0 |
|
- |
| 8.6.1(Lock(key type) leaver thickness) |
- |
0 |
|
- |
| 8.6.1(Lock (key type)Material) |
- |
0 |
|
- |
| 8.6.1(Lock (key type)corrosion protection materail) |
- |
0 |
|
- |
| 8.6.1(Lock(key type) -Endurance test) |
- |
0 |
|
- |
| 8.6.1(Lock(key type)-Bolt forcing test) |
- |
0 |
|
- |
| 8.6.1(Lock(key type)-salt spray solution test) |
- |
0 |
|
- |
| 8.6.1(Lock(key type)-key strength test) |
- |
0 |
|
- |
| 8.6.1(Lock(key type) -Marking) |
- |
0 |
|
- |
| 8.6.1(Lock(Key type) -Key Marking) |
- |
0 |
|
- |
| 8.6.1(Mechanical combination lock -Classification) |
- |
0 |
|
- |
| 8.6.1(Mechanical combination lock -Construction) |
- |
0 |
|
- |
| 8.6.1(Mechanical combination lock -Metallic parts) |
- |
0 |
|
- |
| 8.6.1(Mechanical combination lock -Corrosion Prot) |
- |
0 |
|
- |
| 8.6.1(Mechanical combination lock -Operation test) |
- |
0 |
|
- |
| 8.6.1(Mechanical cmbination lock -Manipulation) |
- |
0 |
|
- |
| 8.6.1(Mechanical combination lock -Punching attack) |
- |
0 |
|
- |
| 8.6.1(Mechanical combination lock -Endurance test) |
- |
0 |
|
- |
| 8.6.1(Mechanical combination lock-Salt spary test) |
- |
0 |
|
- |
| 8.6.1(Mechanical combination lock-Strength test) |
- |
0 |
|
- |
| 8.6.1(Mechanical combination lock-Aging-stress Dist) |
- |
0 |
|
- |
| 8.6.1(Mechanical combination lock-Moisture Absorp) |
- |
0 |
|
- |
| 8.6.1(Mechanical combination lock-Vibration test) |
- |
0 |
|
- |
| 8.6.1(Mechanical combination lock-Marking) |
- |
0 |
|
- |
| 8.6.1(Any other lock) |
- |
0 |
|
- |
| 8.6.4(Lock Bolt engagement) |
- |
0 |
|
- |
| 8.6.5(Additional provision- retrofitting time lock) |
- |
0 |
|
- |
| 8.7(Automatic re-locking device) |
- |
0 |
|
- |
| 8.8(Cable hole size) |
- |
0 |
|
- |
| 9(Internal fixture) |
- |
0 |
|
- |
| 10(Painting) |
- |
0 |
|
- |
| 10.1(Cross hatch test) |
- |
0 |
|
- |
| 11.1(Marking of safe) |
- |
0 |
|
- |
| 12(Burglary attack) |
- |
0 |
|
- |
| 12(Fire Resistance) |
- |
0 |
|
- |
|
08 Feb, 2027 |
- Included w.e.f. 01.04.2025 |
| 4513 |
Ace Test Labs & Metrology Pvt. Ltd., Sonipat
| 9162826
| IS 5244 (2020) |
Safe Deposit Locker Cabinets — Specification ( Fourth Revision ) |
- |
30000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl. 4.1( Types ) |
- |
1000 |
|
- |
| Cl. 6 (Fig-5)(Cabinet Size (in mm)) |
- |
1000 |
|
- |
| Table 1(Thickness Min. (in mm)) |
- |
1000 |
|
- |
| Table 1(Thickness Min. (in mm)) |
- |
1000 |
|
- |
| Table 1(Thickness Min. (in mm)) |
- |
1000 |
|
- |
| Table 1(Thickness Min. (in mm)) |
- |
1000 |
|
- |
| Table 1(Thickness Min. (in mm)) |
- |
1000 |
|
- |
| Table 1(Thickness Min. (in mm)) |
- |
1000 |
|
- |
| Table 1(Thickness Min. (in mm)) |
- |
1000 |
|
- |
| Table 1(Thickness Min. (in mm)) |
- |
1000 |
|
- |
| Table 1(Thickness Min. (in mm)) |
- |
1000 |
|
- |
| Table 1(Thickness Min. (in mm)) |
- |
1000 |
|
- |
| Table 1(Finish) |
- |
1000 |
|
- |
| Table 1(Finish) |
- |
1000 |
|
- |
| Cl.6(Sizes (Minimum Inside Measurements of locker) Locker Size) |
- |
1000 |
|
- |
| Cl.6(Sizes (Minimum Inside Measurements of locker) Locker Size) |
- |
1000 |
|
- |
| Cl.6(Sizes (Minimum Inside Measurements of locker) Locker Size) |
- |
1000 |
|
- |
| Cl. 7.1(Design and Manufacture) |
- |
1000 |
|
- |
| Cl. 7.1(Design and Manufacture) |
- |
1000 |
|
- |
| Cl. 7.1(Design and Manufacture) |
- |
1000 |
|
- |
| Cl. 7.1(Design and Manufacture) |
- |
1000 |
|
- |
| Cl. 7.1(Design and Manufacture) |
- |
1000 |
|
- |
| Cl. 7.2(Design and Manufacture) |
- |
1000 |
|
- |
| Cl. 7.3(Design and Manufacture) |
- |
1000 |
|
- |
| Cl. 7.3(Design and Manufacture) |
- |
1000 |
|
- |
| Cl. 7.4(Design and Manufacture) |
- |
1000 |
|
- |
| Cl. 7.5(Design and Manufacture) |
- |
1000 |
|
- |
| Cl. 7.6(Design and Manufacture) |
- |
1000 |
|
- |
| Cl. 8(Workmanship) |
- |
1000 |
|
- |
| Cl. 8.2(Tolerance) |
- |
1000 |
|
- |
| Cl. 9.1(Testing) |
- |
1000 |
|
- |
| Cl. 9.2(Testing) |
- |
1000 |
|
- |
| Cl. 9.3(Cross Hatch Test) |
- |
1000 |
|
- |
| Cl. 10.1(Marking) |
- |
1000 |
|
- |
| Cl. 10.2(Marking) |
- |
1000 |
|
- |
| Cl. 10.3(Marking) |
- |
1000 |
|
- |
| Cl. 10.4(Marking on Keys) |
- |
1000 |
|
- |
| Cl. 11(Packing) |
- |
1000 |
|
- |
| Cl. 4.1( Types ) |
- |
1000 |
|
- |
| Cl. 6 (Fig-5)(Cabinet Size (in mm)) |
- |
1000 |
|
- |
| Table 1(Thickness Min. (in mm)) |
- |
1000 |
|
- |
| Table 1(Thickness Min. (in mm)) |
- |
1000 |
|
- |
| Table 1(Thickness Min. (in mm)) |
- |
1000 |
|
- |
| Table 1(Thickness Min. (in mm)) |
- |
1000 |
|
- |
| Table 1(Thickness Min. (in mm)) |
- |
1000 |
|
- |
| Table 1(Thickness Min. (in mm)) |
- |
1000 |
|
- |
| Table 1(Thickness Min. (in mm)) |
- |
1000 |
|
- |
| Table 1(Thickness Min. (in mm)) |
- |
1000 |
|
- |
| Table 1(Thickness Min. (in mm)) |
- |
1000 |
|
- |
| Table 1(Thickness Min. (in mm)) |
- |
1000 |
|
- |
| Table 1(Finish) |
- |
1000 |
|
- |
| Table 1(Finish) |
- |
1000 |
|
- |
| Cl.6(Sizes (Minimum Inside Measurements of locker) Locker Size) |
- |
1000 |
|
- |
| Cl.6(Sizes (Minimum Inside Measurements of locker) Locker Size) |
- |
1000 |
|
- |
| Cl.6(Sizes (Minimum Inside Measurements of locker) Locker Size) |
- |
1000 |
|
- |
| Cl. 7.1(Design and Manufacture) |
- |
1000 |
|
- |
| Cl. 7.1(Design and Manufacture) |
- |
1000 |
|
- |
| Cl. 7.1(Design and Manufacture) |
- |
1000 |
|
- |
| Cl. 7.1(Design and Manufacture) |
- |
1000 |
|
- |
| Cl. 7.1(Design and Manufacture) |
- |
1000 |
|
- |
| Cl. 7.2(Design and Manufacture) |
- |
1000 |
|
- |
| Cl. 7.3(Design and Manufacture) |
- |
1000 |
|
- |
| Cl. 7.3(Design and Manufacture) |
- |
1000 |
|
- |
| Cl. 7.4(Design and Manufacture) |
- |
1000 |
|
- |
| Cl. 7.5(Design and Manufacture) |
- |
1000 |
|
- |
| Cl. 7.6(Design and Manufacture) |
- |
1000 |
|
- |
| Cl. 8(Workmanship) |
- |
1000 |
|
- |
| Cl. 8.2(Tolerance) |
- |
1000 |
|
- |
| Cl. 9.1(Testing) |
- |
1000 |
|
- |
| Cl. 9.2(Testing) |
- |
1000 |
|
- |
| Cl. 9.3(Cross Hatch Test) |
- |
1000 |
|
- |
| Cl. 10.1(Marking) |
- |
1000 |
|
- |
| Cl. 10.2(Marking) |
- |
1000 |
|
- |
| Cl. 10.3(Marking) |
- |
1000 |
|
- |
| Cl. 10.4(Marking on Keys) |
- |
1000 |
|
- |
| Cl. 11(Packing) |
- |
1000 |
|
- |
| Cl. 4.1( Types ) |
- |
1000 |
|
- |
| Cl. 6 (Fig-5)(Cabinet Size (in mm)) |
- |
1000 |
|
- |
| Table 1(Thickness Min. (in mm)) |
- |
1000 |
|
- |
| Table 1(Thickness Min. (in mm)) |
- |
1000 |
|
- |
| Table 1(Thickness Min. (in mm)) |
- |
1000 |
|
- |
| Table 1(Thickness Min. (in mm)) |
- |
1000 |
|
- |
| Table 1(Thickness Min. (in mm)) |
- |
1000 |
|
- |
| Table 1(Thickness Min. (in mm)) |
- |
1000 |
|
- |
| Table 1(Thickness Min. (in mm)) |
- |
1000 |
|
- |
| Table 1(Thickness Min. (in mm)) |
- |
1000 |
|
- |
| Table 1(Thickness Min. (in mm)) |
- |
1000 |
|
- |
| Table 1(Thickness Min. (in mm)) |
- |
1000 |
|
- |
| Table 1(Finish) |
- |
1000 |
|
- |
| Table 1(Finish) |
- |
1000 |
|
- |
| Cl.6(Sizes (Minimum Inside Measurements of locker) Locker Size) |
- |
1000 |
|
- |
| Cl.6(Sizes (Minimum Inside Measurements of locker) Locker Size) |
- |
1000 |
|
- |
| Cl.6(Sizes (Minimum Inside Measurements of locker) Locker Size) |
- |
1000 |
|
- |
| Cl. 7.1(Design and Manufacture) |
- |
1000 |
|
- |
| Cl. 7.1(Design and Manufacture) |
- |
1000 |
|
- |
| Cl. 7.1(Design and Manufacture) |
- |
1000 |
|
- |
| Cl. 7.1(Design and Manufacture) |
- |
1000 |
|
- |
| Cl. 7.1(Design and Manufacture) |
- |
1000 |
|
- |
| Cl. 7.2(Design and Manufacture) |
- |
1000 |
|
- |
| Cl. 7.3(Design and Manufacture) |
- |
1000 |
|
- |
| Cl. 7.3(Design and Manufacture) |
- |
1000 |
|
- |
| Cl. 7.4(Design and Manufacture) |
- |
1000 |
|
- |
| Cl. 7.5(Design and Manufacture) |
- |
1000 |
|
- |
| Cl. 7.6(Design and Manufacture) |
- |
1000 |
|
- |
| Cl. 8(Workmanship) |
- |
1000 |
|
- |
| Cl. 8.2(Tolerance) |
- |
1000 |
|
- |
| Cl. 9.1(Testing) |
- |
1000 |
|
- |
| Cl. 9.2(Testing) |
- |
1000 |
|
- |
| Cl. 9.3(Cross Hatch Test) |
- |
1000 |
|
- |
| Cl. 10.1(Marking) |
- |
1000 |
|
- |
| Cl. 10.2(Marking) |
- |
1000 |
|
- |
| Cl. 10.3(Marking) |
- |
1000 |
|
- |
| Cl. 10.4(Marking on Keys) |
- |
1000 |
|
- |
| Cl. 11(Packing) |
- |
1000 |
|
- |
|
14 Nov, 2027 |
- Included w.e.f. 28.03.2025 |
| 4514 |
URS PRODUCTS AND TESTING PVT. LTD. (A29), NOIDA
| 8168906
| IS 15558 (2005) |
Mini domestic water heater for use with LPG - Specification |
- |
9700 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 17(Combustion) |
- |
800 |
|
- |
| 6.1(Connections) |
- |
200 |
|
- |
| 6.2(Connections) |
- |
200 |
|
- |
| 6.3(Connections) |
- |
200 |
|
- |
| 6.4(Connections) |
- |
200 |
|
- |
| 6.5(Connections) |
- |
200 |
|
- |
| 6.6(Gas Inlet Connections) |
- |
200 |
|
- |
| 6.6(Gas Inlet Connections) |
- |
200 |
|
- |
| 6.6(Gas Inlet Connections) |
- |
200 |
|
- |
| 6.6(Gas Inlet Connections) |
- |
200 |
|
- |
| 6.6(Gas Inlet Connections) |
- |
200 |
|
- |
| 6.6(Gas Inlet Connections) |
- |
200 |
|
- |
| 24(Fire Hazard And Limiting Temperature ) |
- |
500 |
|
- |
| 24(Fire Hazard And Limiting Temperature) |
- |
500 |
|
- |
| 24(Fire Hazard And Limiting Temperature) |
- |
500 |
|
- |
| 24(Fire Hazard And Limiting Temperature) |
- |
500 |
|
- |
| 9(Flame Failure Device) |
- |
400 |
|
- |
| 20(Flame Stability) |
- |
500 |
|
- |
| 7(Flame Visibility) |
- |
300 |
|
- |
| 22(Flash Back) |
- |
400 |
|
- |
| 18(Gas Consumption) |
- |
800 |
|
- |
| 14(Gas Soundness) |
- |
500 |
|
- |
| 8(Gas Taps) |
- |
300 |
|
- |
| 19.1(Ignition and flame travel) |
- |
500 |
|
- |
| 19.2(Ignition and flame travel) |
- |
500 |
|
- |
| 19.3(Ignition and flame travel) |
- |
500 |
|
- |
| 10(Ignition Device) |
- |
400 |
|
- |
| 5.1(Materials) |
- |
200 |
|
- |
| 5.2(Materials) |
- |
200 |
|
- |
| 5.3(Materials) |
- |
200 |
|
- |
| 5.4(Materials) |
- |
200 |
|
- |
| 5.5(Materials) |
- |
200 |
|
- |
| 21(Noise Control) |
- |
400 |
|
- |
| 11(Protection Against Accidental Overheating) |
- |
400 |
|
- |
| 23(Resistance to Draught) |
- |
400 |
|
- |
| 16(Thermal Efficiency) |
- |
800 |
|
- |
| 16(Thermal Efficiency) |
- |
800 |
|
- |
| 25(Time For Temperature Rise) |
- |
500 |
|
- |
| 4.1.1(Construction) |
- |
200 |
|
- |
| 4.1.2(Construction) |
- |
200 |
|
- |
| 4.1.3(Construction) |
- |
200 |
|
- |
| 4.1.4(Construction) |
- |
200 |
|
- |
| 4.1.5(Construction) |
- |
200 |
|
- |
| 4.1.6(Construction) |
- |
200 |
|
- |
| 4.1.7(Construction) |
- |
200 |
|
- |
| 4.1.8(Construction) |
- |
200 |
|
- |
| 4.1.9(Construction) |
- |
200 |
|
- |
| 4.1.10(Construction) |
- |
200 |
|
- |
| 4.1.11(Construction) |
- |
400 |
|
- |
| 4.1.12(Construction) |
- |
200 |
|
- |
| 26(Hot Water Output Test) |
- |
800 |
|
- |
| 27(Marking) |
- |
200 |
|
- |
| 12(Water Rate Adjuster) |
- |
500 |
|
- |
| 15(Water Soundness) |
- |
500 |
|
- |
|
26 Sep, 2027 |
- - |
| 4515 |
ACCURATE TEST SOLUTIONS LLP (F21), NOIDA
| 8141226
| IS 302 : Part 2 : Sec 30 (2007) |
Safety of household and similar electrical appliances: Part 2 particular requirements: Sec 30 room heaters (First Revision) |
- |
20000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl.6 (Classification) |
- |
500 |
|
- |
| Cl.6 (Classification) |
- |
500 |
|
- |
| Cl.7 & IS:302-1:2008(Marking and Instructions) |
- |
500 |
|
- |
| Cl.7 & IS:302-1:2008(Marking and Instructions) |
- |
500 |
|
- |
| Cl.7 & IS:302-1:2008(Marking and Instructions) |
- |
500 |
|
- |
| Cl.7 & IS:302-1:2008(Marking and Instructions) |
- |
500 |
|
- |
| Cl.7 & IS:302-1:2008(Marking and Instructions) |
- |
500 |
|
- |
| Cl.7 & IS:302-1:2008(Marking and Instructions) |
- |
500 |
|
- |
| Cl.7 & IS:302-1:2008(Marking and Instructions) |
- |
500 |
|
- |
| Cl.7 & IS:302-1:2008(Marking and Instructions) |
- |
500 |
|
- |
| Cl.7 & IS:302-1:2008(Marking and Instructions) |
- |
500 |
|
- |
| Cl.7(Marking and Instructions) |
- |
500 |
|
- |
| Cl.7(Marking and Instructions) |
- |
500 |
|
- |
| Cl.7(Marking and Instructions) |
- |
500 |
|
- |
| Cl.7.3(Marking and Instructions) |
- |
500 |
|
- |
| Cl.7.3(Marking and Instructions) |
- |
500 |
|
- |
| Cl.7.3(Marking and Instructions) |
- |
500 |
|
- |
| Cl.7.4(Marking and Instructions) |
- |
500 |
|
- |
| Cl.7.5(Marking and Instructions) |
- |
500 |
|
- |
| Cl.7.6 & IS:302-1:2008(Marking and Instructions) |
- |
500 |
|
- |
| Cl.7.8 of IS :302-1:2008(Marking and Instructions) |
- |
500 |
|
- |
| Cl.7.9 of IS :302-1:2008(Marking and Instructions) |
- |
500 |
|
- |
| Cl.7.10 of IS :302-1:2008(Marking and Instructions) |
- |
500 |
|
- |
| Cl.7.11 of IS :302-1:2008(Marking and Instructions) |
- |
500 |
|
- |
| Cl.7.12 & IS:302-1:2008(Marking and Instructions) |
- |
500 |
|
- |
| Cl.7.12 & IS:302-1:2008(Marking and Instructions) |
- |
500 |
|
- |
| Cl.7.12 & IS:302-1:2008(Marking and Instructions) |
- |
500 |
|
- |
| Cl.7.12 & IS:302-1:2008(Marking and Instructions) |
- |
500 |
|
- |
| Cl.7.12 & IS:302-1:2008(Marking and Instructions) |
- |
500 |
|
- |
| Cl.7.12 & IS:302-1:2008(Marking and Instructions) |
- |
500 |
|
- |
| Cl.7.12 & IS:302-1:2008(Marking and Instructions) |
- |
500 |
|
- |
| Cl.7.12 & IS:302-1:2008(Marking and Instructions) |
- |
500 |
|
- |
| Cl.7.12 & IS:302-1:2008(Marking and Instructions) |
- |
500 |
|
- |
| Cl.7.12 & IS:302-1:2008(Marking and Instructions) |
- |
500 |
|
- |
| Cl.7.12 & IS:302-1:2008(Marking and Instructions) |
- |
500 |
|
- |
| Cl.7.12 & IS:302-1:2008(Marking and Instructions) |
- |
500 |
|
- |
| Cl.7.12.1 & IS:302-1:2008(Marking and Instructions) |
- |
500 |
|
- |
| Cl.7.12.1 & IS:302-1:2008(Marking and Instructions) |
- |
500 |
|
- |
| Cl.7.12.1 & IS:302-1:2008(Marking and Instructions) |
- |
500 |
|
- |
| Cl.7.12.1 & IS:302-1:2008(Marking and Instructions) |
- |
500 |
|
- |
| Cl.7.12.1 & IS:302-1:2008(Marking and Instructions) |
- |
500 |
|
- |
| Cl.7.12.1 & IS:302-1:2008(Marking and Instructions) |
- |
500 |
|
- |
| Cl.7.12.1 & IS:302-1:2008(Marking and Instructions) |
- |
500 |
|
- |
| Cl.7.12.1 & IS:302-1:2008(Marking and Instructions) |
- |
500 |
|
- |
| Cl.7.12.1 & IS:302-1:2008(Marking and Instructions) |
- |
500 |
|
- |
| Cl.7.12.1 & IS:302-1:2008(Marking and Instructions) |
- |
500 |
|
- |
| Cl.7.12.1 & IS:302-1:2009(Marking and Instructions) |
- |
500 |
|
- |
| Cl.7.13 of IS 302-1:2008(Marking and Instructions) |
- |
500 |
|
- |
| Cl.7.14 of IS302-1:2008(Marking and Instructions) |
- |
500 |
|
- |
| Cl.7.14(Marking and Instructions) |
- |
500 |
|
- |
| Cl.7.14(Marking and Instructions) |
- |
500 |
|
- |
| Cl.7.15 of IS 302-1:2008(Marking and Instructions) |
- |
500 |
|
- |
| Cl.7.15 of IS 302-1:2008(Marking and Instructions) |
- |
500 |
|
- |
| Cl.7.15 of IS 302-1:2008(Marking and Instructions) |
- |
500 |
|
- |
| Cl.7.15 of IS 302-1:2008(Marking and Instructions) |
- |
500 |
|
- |
| Cl.7.101(Marking and Instructions) |
- |
500 |
|
- |
| Cl.8 & IS:302-1:2008(Protection Against Access to Live Parts) |
- |
500 |
|
- |
| Cl.10 & IS:302-1:2008(Power Input and Current) |
- |
500 |
|
- |
| Cl.11 & IS:302-1:2008(Heating) |
- |
500 |
|
- |
| Cl.11 & IS:302-1:2008(Heating) |
- |
500 |
|
- |
| Cl.11 & IS:302-1:2008(Heating) |
- |
500 |
|
- |
| Cl.11 & IS:302-1:2008(Heating) |
- |
500 |
|
- |
| Cl.11 & IS:302-1:2008(Heating) |
- |
500 |
|
- |
| Cl.11 & IS:302-1:2008(Heating) |
- |
500 |
|
- |
| Cl.11 & IS:302-1:2008(Heating) |
- |
500 |
|
- |
| Cl.11 & IS:302-1:2008(Heating) |
- |
500 |
|
- |
| Cl.11 & IS:302-1:2008(Heating) |
- |
500 |
|
- |
| Cl.11 & IS:302-1:2008(Heating) |
- |
500 |
|
- |
| Cl.11 & IS:302-1:2008(Heating) |
- |
500 |
|
- |
| Cl.11 & IS:302-1:2008(Heating) |
- |
500 |
|
- |
| Cl.11 & IS:302-1:2008(Heating) |
- |
500 |
|
- |
| Cl.11 & IS:302-1:2008(Heating) |
- |
500 |
|
- |
| Cl.11 & IS:302-1:2008(Heating) |
- |
500 |
|
- |
| Cl.11 & IS:302-1:2008(Heating) |
- |
500 |
|
- |
| Cl.11.8(Heating) |
- |
500 |
|
- |
| Cl.11.8(Heating) |
- |
500 |
|
- |
| Cl.11.8(Heating) |
- |
500 |
|
- |
| Cl.13 & IS:302-1:2008(Leakage Current & Electric Strength at operating temp. ) |
- |
500 |
|
- |
| Cl.13 & IS:302-1:2008(Leakage Current & Electric Strength at operating temp. ) |
- |
500 |
|
- |
| Cl.14 & IS:302-1:2008(Transient Over Voltages) |
- |
500 |
|
- |
| Cl.15 & IS: 302-1:2008(Moisture Resistance
) |
- |
500 |
|
- |
| Cl.15.3 of IS 302-1:200(Moisture Resistance
) |
- |
500 |
|
- |
| Cl.16 & IS:302-1:2008(Leakage Current & Electric Strength ) |
- |
500 |
|
- |
| Cl.16 & IS:302-1:2008(Leakage Current & Electric Strength ) |
- |
500 |
|
- |
| Cl.17 & IS:302-1:2008(Over load Protection of Transformers and Associated Circuits ) |
- |
500 |
|
- |
| Cl.18 (Endurance. ) |
- |
0 |
|
- |
| Cl.19 & IS:302-1:2008(Abnormal Operation.) |
- |
500 |
|
- |
| Cl.19 & IS:302-1:2008(Abnormal Operation.) |
- |
500 |
|
- |
| Cl.19 & IS:302-1:2008(Abnormal Operation.) |
- |
500 |
|
- |
| Cl.19 & IS:302-1:2008(Abnormal Operation.) |
- |
500 |
|
- |
| Cl.19.101(Abnormal Operation.) |
- |
500 |
|
- |
| Cl.19.102(Abnormal Operation.) |
- |
500 |
|
- |
| Cl.19.103(Abnormal Operation.) |
- |
500 |
|
- |
| Cl.19.104(Abnormal Operation.) |
- |
500 |
|
- |
| Cl.19.105(Abnormal Operation.) |
- |
500 |
|
- |
| Cl.19.106(Abnormal Operation.) |
- |
500 |
|
- |
| Table 8 of IS 302-1:2008(Abnormal Operation.) |
- |
500 |
|
- |
| Cl.19.107(Abnormal Operation.) |
- |
500 |
|
- |
| Cl.19.108(Abnormal Operation.) |
- |
500 |
|
- |
| Cl.19.109(Abnormal Operation.) |
- |
500 |
|
- |
| Cl.19.110(Abnormal Operation.) |
- |
500 |
|
- |
| Cl.19.111(Abnormal Operation.) |
- |
500 |
|
- |
| Cl.19.112(Abnormal Operation.) |
- |
500 |
|
- |
| Cl.19.113(Abnormal Operation.) |
- |
500 |
|
- |
| Cl.19.114(Abnormal Operation.) |
- |
500 |
|
- |
| Cl.20 & IS:302-1:2008(Stability & Mechanical Hazards) |
- |
500 |
|
- |
| Cl.21 & IS:302-1:2008)(Mechanical Strength.) |
- |
500 |
|
- |
| Cl.21.2 of IS 302-1:2008(Mechanical Strength.) |
- |
500 |
|
- |
| Cl.21.101 (Mechanical Strength.) |
- |
500 |
|
- |
| Cl.21.102(Mechanical Strength.) |
- |
500 |
|
- |
| Cl.21.103(Mechanical Strength.) |
- |
500 |
|
- |
| Cl.22.1 of IS 302-1:2008(Construction) |
- |
500 |
|
- |
| Cl.22.5 of IS 302-1:2008(Construction) |
- |
500 |
|
- |
| Cl.22.6 of IS 302-1:2008(Construction) |
- |
500 |
|
- |
| Cl.22.7 of IS 302-1:2008(Construction) |
- |
500 |
|
- |
| Cl.22.8 of IS 302-1:2008(Construction) |
- |
500 |
|
- |
| Cl.22.9 of IS 302-1:2008(Construction) |
- |
500 |
|
- |
| Cl.22.11(Construction) |
- |
500 |
|
- |
| Cl.22.12 of IS 302-1:2008(Construction) |
- |
500 |
|
- |
| Cl.22.13 of IS 302-1:2008(Construction) |
- |
500 |
|
- |
| Cl.22.14 of IS 302-1:2008(Construction) |
- |
500 |
|
- |
| Cl.22.15 of IS 302-1:2008(Construction) |
- |
500 |
|
- |
| Cl.22.18 of IS 302-1:2008(Construction) |
- |
500 |
|
- |
| Cl.22.20 of IS 302-1:2008(Construction) |
- |
500 |
|
- |
| Cl.22.21 of IS 302-1:2008(Construction) |
- |
500 |
|
- |
| Cl.23 & IS:302-1:2008(Internal Wiring
) |
- |
500 |
|
- |
| Cl.23.4 & Cl.29 of 302-1:2008(Internal Wiring
) |
- |
500 |
|
- |
| Cl.23.5 of 302-1:2008(Internal Wiring
) |
- |
500 |
|
- |
| Cl.23.7 of 302-1:2008(Internal Wiring
) |
- |
500 |
|
- |
| C.23.7 of 302-1:2008(Internal Wiring
) |
- |
500 |
|
- |
| Cl.25.1 of 302-1:2008(Supply Connection and External Flexible Cords ) |
- |
500 |
|
- |
| Cl. 25.2 of IS 3021:2008(Supply Connection and External Flexible Cords ) |
- |
500 |
|
- |
| Cl. 25.3 of IS 302-1:2008(Supply Connection and External Flexible Cords ) |
- |
500 |
|
- |
| Cl. 25.4 of IS 302-1:2008(Supply Connection and External Flexible Cords ) |
- |
500 |
|
- |
| Cl.25.5 of 302-1:2008(Supply Connection and External Flexible Cords ) |
- |
500 |
|
- |
| Cl.25.7.(Supply Connection and External Flexible Cords ) |
- |
500 |
|
- |
| Cl.25.8(Supply Connection and External Flexible Cords ) |
- |
500 |
|
- |
| Cl. 25.9(Supply Connection and External Flexible Cords ) |
- |
500 |
|
- |
| Cl.25.10 of 302-1:2008(Supply Connection and External Flexible Cords ) |
- |
500 |
|
- |
| Cl. 25.11(Supply Connection and External Flexible Cords ) |
- |
500 |
|
- |
| Cl. 25.12(Supply Connection and External Flexible Cords ) |
- |
500 |
|
- |
| Cl. 25.13(Supply Connection and External Flexible Cords ) |
- |
500 |
|
- |
| Cl.25.14 of IS 302-1:2008(Supply Connection and External Flexible Cords ) |
- |
500 |
|
- |
| Cl.25.15 of IS 302-1:2008(Supply Connection and External Flexible Cords ) |
- |
500 |
|
- |
| Cl.25.15 of IS 302-1:2008(Supply Connection and External Flexible Cords ) |
- |
500 |
|
- |
| Cl.25.18(Supply Connection and External Flexible Cords ) |
- |
500 |
|
- |
| Cl.25.20(Supply Connection and External Flexible Cords ) |
- |
500 |
|
- |
| Cl.26.1 of IS 302-1:2008(Terminal for External Conductors
) |
- |
500 |
|
- |
| Cl.26.10 of IS 302-1:2008(Terminal for External Conductors
) |
- |
500 |
|
- |
| Cl.26.11 of IS 302-1:2008(Terminal for External Conductors
) |
- |
500 |
|
- |
| Cl.27.1 of 302-1:2008(Provision for Earthing.) |
- |
500 |
|
- |
| Cl.27.5 of 302-1:2008(Provision for Earthing.) |
- |
500 |
|
- |
| Cl.28 of 302-1:2008(Screws and Connections.) |
- |
500 |
|
- |
| Cl.29 & IS:302-1:2008(Clearances, Creepage Distances and Solid Insulation) |
- |
500 |
|
- |
| Cl.29 & IS:302-1:2008(Clearances, Creepage Distances and Solid Insulation) |
- |
500 |
|
- |
| Cl.30 & IS:302-1:2008(Resistance to Heat and Fire) |
- |
500 |
|
- |
| Cl.30.2.2 of 302-1:2008(Resistance to Heat and Fire) |
- |
500 |
|
- |
| Cl.31 & IS:302-1:2008(Resistance to Rusting.) |
- |
500 |
|
- |
| Cl.32 & IS:302-1:2008(Radition,Toxicity and similar Hazards.) |
- |
500 |
|
- |
| Cl.31 of IS:302-1:2008(Resistance to Rusting.) |
- |
500 |
|
- |
| Cl.30.2 of 302-1:2008(Resistance to Heat and Fire : Resistance to fire) |
- |
500 |
|
- |
| Cl.30.1 of IS:302-1:2008(Resistance to Heat and Fire: Resistance to heat. ) |
- |
500 |
|
- |
| Cl.29.2 of IS:302-1:2008(Clearances, Creepage Distances and Solid Insulation : Creepage Distance) |
- |
500 |
|
- |
| Cl.29.1 of IS:302-1:2008(Clearances, Creepage Distances and Solid Insulation : Clearance ) |
- |
500 |
|
- |
| Cl.28 of 302-1:2008(Screws and Connections.) |
- |
500 |
|
- |
| Cl.27.5 of 302-1:2008(Provision for Earthing : ECR) |
- |
500 |
|
- |
| Cl.27.1 of 302-1:2008(Provision for Earthing ) |
- |
500 |
|
- |
| Cl.26 of IS 302-1:2008(Terminal for External Conductors
) |
- |
500 |
|
- |
| Cl.25.20 of 302-1:2008(Supply Connection and External Flexible Cords : Additional insulation ) |
- |
500 |
|
- |
| Cl.25.18 of 302-1:2008(Supply Connection and External Flexible Cords : Arrangement of cord anchorages ) |
- |
500 |
|
- |
| Cl.25.15 of IS 302-1:2008(Supply Connection and External Flexible Cords : Cord grip test - displacement) |
- |
500 |
|
- |
| Cl.25.15 of IS 302-1:2008(Supply Connection and External Flexible Cords : Cord grip test - strain at terminals ) |
- |
500 |
|
- |
| Cl. 25.13 of 302-1:2008(Supply Connection and External Flexible Cords : Inlet opening of supply cords ) |
- |
500 |
|
- |
| Cl. 25.12 of 302-1:2008(Supply Connection and External Flexible Cords : Moulding of cords ) |
- |
500 |
|
- |
| Cl.25.10 of 302-1:2008(Supply Connection and External Flexible Cords : Colour of earthing wire ) |
- |
500 |
|
- |
| Cl. 25.9 of 302-1:2008(Supply Connection and External Flexible Cords : Contact with sharp edge ) |
- |
500 |
|
- |
| Cl.25.8 of 302-1:2008(Supply Connection and External Flexible Cords : Resistance of supply wires ) |
- |
500 |
|
- |
| Cl.25.7 of IS:302-2-30:2007(Supply Connection and External Flexible Cords : Supply cords material ) |
- |
500 |
|
- |
| Cl.25.5 of 302-1:2008(Supply Connection and External Flexible Cords : Type of attachments ) |
- |
500 |
|
- |
| Cl.25.1 of 302-1:2008(Supply Connection and External Flexible Cords : Means of connection ) |
- |
500 |
|
- |
| Cl.23.7 of 302-1:2008(Internal Wiring : Colour of earting conductor
) |
- |
500 |
|
- |
| Cl.23 of IS:302-1:2008(Internal Wiring
) |
- |
500 |
|
- |
| Cl.22.106 of IS:302-2-30:2007(Construction : Checking of thermostats, timers or similar means for visibl glowing radiant heaters) |
- |
500 |
|
- |
| Cl.22.106 of IS:302-2-30:2007(Construction : Checking of openings on the underside) |
- |
500 |
|
- |
| Cl.22.102 & Cl 22.103 of IS:302-2-30:2007(Construction : Fireguard ) |
- |
500 |
|
- |
| Cl.22.101 of IS:302-2-30:2007(Construction : Prevention to contact with heating element) |
- |
500 |
|
- |
| Cl.22.24 of IS:302-2-30:2007(Construction : test of bare heating element) |
- |
500 |
|
- |
| Cl.22.18 of IS 302-1:2008(Construction : Resistance to corrosion ) |
- |
500 |
|
- |
| Cl.22.15 of IS 302-1:2008(Construction : Storage hooks for flexible cords) |
- |
500 |
|
- |
| Cl.22.14 of IS 302-1:2008(Construction : ragged and sharp edges) |
- |
500 |
|
- |
| Cl.22.13 of IS 302-1:2008(Construction : Position of handles ) |
- |
500 |
|
- |
| Cl.22.12 of IS 302-1:2008(Construction : Fixing of Handle, knobs,grips,lever and similer parts ) |
- |
500 |
|
- |
| Cl.22.11 of IS 302-1:2008(Construction : Fixing of non detachable parts ) |
- |
500 |
|
- |
| Cl.22.7 of IS:302-2-30:2007(Construction : Pressure test of oil heater ) |
- |
500 |
|
- |
| Cl.21.101 of IS:302-2-30:2007(Mechanical Strength : fire gaurd deformation test ) |
- |
500 |
|
- |
| Cl.21.2 of IS 302-1:2008(Mechanical Strength : Pentration by sharp implementation ) |
- |
500 |
|
- |
| Cl.21.1 of IS:302-1:2008)(Mechanical Strength : Rough handling ) |
- |
500 |
|
- |
| Cl.20 of IS:302-2-30:2007(Stability of Mechanical Hazards) |
- |
500 |
|
- |
| Cl.19.114 of IS:302-2-30:2007(Abnormal Operation : the temp. of the surface of the container for oil heaters ) |
- |
500 |
|
- |
| Cl.19.112 of IS:302-2-30:2007(Abnormal Operation : Ignition of bleached cotton gauge) |
- |
500 |
|
- |
| Cl.19.111 of IS:302-2-30:2007(Abnormal Operation : Ignition of flannelette for Visibly glowing heaters) |
- |
500 |
|
- |
| Cl.19.110 of IS:302-2-30:2007(Abnormal Operation : operation against wall for visibly glowing radiant heaters ) |
- |
500 |
|
- |
| Cl.19.109 of IS:302-2-30:2007(Abnormal Operation : operation against wall for fan heater ) |
- |
500 |
|
- |
| Cl.19.106 of IS:302-2-30:2007(Abnormal Operation : Locked rotor of fan hetear ) |
- |
500 |
|
- |
| Cl.19.103 , Cl 19.104 of IS:302-2-30:2007(Abnormal Operation : Operation after Covering by cotton) |
- |
500 |
|
- |
| Cl.19 of IS:302-2-30:2007(Abnormal Operation : High Voltage ) |
- |
500 |
|
- |
| Cl.19 of IS:302-2-30:2007(Abnormal Operation : Temp rise of test corner ) |
- |
500 |
|
- |
| Cl.19 of IS:302-2-30:2007(Abnormal Operation : temp rise of supply cord ) |
- |
500 |
|
- |
| Cl.19 of IS:302-1:2008(Abnormal Operation : Emission of molten or poisonous or ignitable gas) |
- |
500 |
|
- |
| Cl.16 of IS:302-1:2008(Leakage current and Electric strength (After humidity): Electric Strentgh ) |
- |
500 |
|
- |
| Cl.16 of IS:302-1:2008(Leakage current and Electric strength (After humidity): Leakage current ) |
- |
500 |
|
- |
| Cl.15 of IS 302-1:2008(Moisture Resistance
) |
- |
500 |
|
- |
| Cl.14 of IS:302-1:2008(Transient Over Voltages) |
- |
500 |
|
- |
| Cl.13 of IS:302-1:2008(Leakage Current of Electric Strength at operating temp. ) |
- |
500 |
|
- |
| Cl.13 of IS:302-1:2008(Leakage Current of Electric Strength at operating temp. ) |
- |
500 |
|
- |
| Cl.11 of IS:302-2:30: 2007(Heating : Room temperature) |
- |
500 |
|
- |
| Cl.11.8 of IS:302-2:30: 2007(Heating : For liquid filled radiators the temp. rise of the outer surface of the liquid container) |
- |
500 |
|
- |
| Cl.11 of IS:302-2:30: 2007(Heating : Temperature rise in winding) |
- |
500 |
|
- |
| Cl.11 of IS:302-2:30: 2007(Heating : Air-outlet grills) |
- |
500 |
|
- |
| Cl.11 of IS:302-2:30: 2007(Heating : Surfaces of handles, knobs, grips and similar parts) |
- |
500 |
|
- |
| Cl.11 of IS:302-2:30: 2007(Heating : Wooden supports, walls, ceiling and floor of the test corner) |
- |
500 |
|
- |
| Cl.11 of IS:302-2:30: 2007(Heating : PVC Insulation ) |
- |
500 |
|
- |
| Cl.10 of IS:302-1:2008(Power Input and Current) |
- |
500 |
|
- |
| Cl.8 of IS:302-1:2008(Protection Against Access to Live Parts) |
- |
500 |
|
- |
| Cl.7.101 of IS:302-2:30: 2007(Marking and Instructions : standard mark. ) |
- |
500 |
|
- |
| Cl.7.15 of IS 302-1:2008(Marking and Instructions : Visibility of marking concerning covering) |
- |
500 |
|
- |
| Cl.7.15 of IS 302-1:2008(Marking and Instructions : discernibility from the out side ) |
- |
500 |
|
- |
| Cl.7.14 of IS:302-2:30: 2007(Marking and Instructions : Height of “Do not cover”) |
- |
500 |
|
- |
| Cl.7.14 of IS:302-2:30: 2007(Marking and Instructions : height of symbol) |
- |
500 |
|
- |
| Cl.7.14 of IS302-1:2008(Marking and Instructions : Legibility and durability ) |
- |
500 |
|
- |
| Cl.7.13 of IS 302-1:2008(Marking and Instructions : Languge of instruction and texts ) |
- |
500 |
|
- |
| Cl.7.11 of IS :302-1:2008(Marking and Instructions : Controls ) |
- |
500 |
|
- |
| Cl.7.9 of IS :302-1:2008(Marking and Instructions : switches ) |
- |
500 |
|
- |
| Cl.7.8 of IS :302-1:2008(Marking and Instructions : terminals ) |
- |
500 |
|
- |
| Cl.7.6 of IS:302-1:2008(Marking and Instructions : Symbols ) |
- |
500 |
|
- |
| Cl.7.5 of IS:302-1:2008(Marking and Instructions : upper of lower limit of the rated power input ) |
- |
500 |
|
- |
| Cl 7.1 & Cl.7.6 of IS:302-2:30: 2007(Marking and Instructions : Do not cover ) |
- |
500 |
|
- |
| Cl.7.1 of IS:302-1:2008(Marking and Instructions : Country of manufacture ) |
- |
500 |
|
- |
| Cl.7.1 of IS:302-1:2008(Marking and Instructions : Symbol for Class-II ) |
- |
500 |
|
- |
| Cl.7.1 of IS:302-1:2008(Marking and Instructions : Model or type ) |
- |
500 |
|
- |
| Cl.7.1 of IS:302-1:2008(Marking and Instructions : Name , trade-mark or identification mark of the manufacturer ) |
- |
500 |
|
- |
| Cl.7.1 of IS:302-1:2008(Marking and Instructions : rated power input ) |
- |
500 |
|
- |
| Cl.7.1 of IS:302-1:2008(Marking and Instructions : Nature of supply ) |
- |
500 |
|
- |
| Cl.7.1 of IS:302-1:2008(Marking and Instructions : Rated Voltage ) |
- |
500 |
|
- |
| Cl.25.6 of 302-1:2008(Supply Connection and External Flexible Cords ) |
- |
500 |
|
- |
| Cl.25.17 of IS 302-1:2008(Supply Connection and External Flexible Cords ) |
- |
500 |
|
- |
| Cl.24.1 of 302-1:2008(Component) |
- |
0 |
|
- |
| Cl.24.1 of 302-1:2008(Component) |
- |
0 |
|
- |
| Cl.24.1.3 (Component) |
- |
0 |
|
- |
| Cl.24.1.3 (Component) |
- |
0 |
|
- |
| Cl.24.1.3 (Component) |
- |
0 |
|
- |
| Cl.24.1.3 (Component) |
- |
0 |
|
- |
| C.24.1.4(Component) |
- |
0 |
|
- |
| C.24.2 of 302-1:2008(Component) |
- |
0 |
|
- |
| Cl.24.10(Component) |
- |
0 |
|
- |
| Cl.24 of IS:302-2-30:2007(Component) |
- |
0 |
|
- |
| 19.11.4.1(Electrostatic discharges) |
- |
0 |
|
- |
| 19.11.4.2(Radiated fields) |
- |
0 |
|
- |
| 19.11.4.3(Fast transient bursts) |
- |
0 |
|
- |
| 19.11.4.4(Surge immunity test) |
- |
0 |
|
- |
| 19.11.4.5(Injected currents) |
- |
0 |
|
- |
| 19.11.4.6(Class 3 Voltage dips and interruptions) |
- |
0 |
|
- |
| 19.11.4.7(Harmonics) |
- |
0 |
|
- |
|
04 Jul, 2027 |
- Included w.e.f.17.03.2025
Exclusion
Cl 19.11.4.1 to Cl 19.11.4.7 (EMI/EMC)
Cl 24 (Components) |
| 4516 |
Alpha Test House Services LLP (160), Sahibzada Ajit Singh Nagar
| 9138706
| IS 1364 : Part 1 (2023) |
Hexagon head bolts, screws, and nuts of property grades A and B: Part 1 Hexagon head bolts (Size range M1.6 to M64) (sixth revision) |
M 1.6 -M 64 |
25000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl-4(Dimensions) |
- |
25000 |
|
- |
| Cl-5, Table-7(General requirements) |
- |
25000 |
|
- |
| Cl-5, Table-7(Thread-Tolerance class) |
- |
25000 |
|
- |
| Cl-5, Table-7(Mechanical properties- Steel) |
- |
25000 |
|
- |
| Cl-5, Table-7(Mechanical properties-Stainless steel) |
- |
25000 |
|
- |
| Cl-5, Table-7(Tolerances-Product grade) |
- |
25000 |
|
- |
| Cl-5, Table-7(Surface condition -Electroplated coatings) |
- |
25000 |
|
- |
| Cl-5, Table-7(Surface condition- Non-electrolytically applied zinc flake) |
- |
1000 |
|
- |
| Cl-5, Table-7(Surface condition - Hot dip galvanized coatings) |
- |
1000 |
|
- |
| Cl-5, Table-7(Surface integrity- Limits for surface discontinuities) |
- |
1000 |
|
- |
| Cl-6(Marking) |
- |
25000 |
|
- |
|
31 Dec, 2026 |
- - |
| 4517 |
Alpha Test House Services LLP (160), Sahibzada Ajit Singh Nagar
| 9138706
| IS 1364 : Part 2 (2018) |
Hexagon head bolts, screws and nuts of product grades A and B: Part 2 hexagon head screws (Size Range M 1.6 To M 64) (Fifth Revision) |
M 1.6- M 64 |
25000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 3(dimensions) |
- |
25000 |
|
- |
| 4(Material) |
- |
25000 |
|
- |
| 4(Thread requirements) |
- |
25000 |
|
- |
| 5(Designation) |
- |
25000 |
|
- |
| 9.1 to 9.5, 9.7(Tensile Test) |
- |
25000 |
|
- |
| 9.8(Head Soundness Test) |
- |
25000 |
|
- |
| 9.13(Torsion Test) |
- |
25000 |
|
- |
| 9.14(Impact Test) |
- |
25000 |
|
- |
| 9.9(Hardness Test) |
- |
25000 |
|
- |
| 9.1(Decarburization Test) |
- |
25000 |
|
- |
| 9.11(Carburization test) |
- |
25000 |
|
- |
| 9.12(Re tempering test) |
- |
25000 |
|
- |
| 9.15(Surface discontinuity test) |
- |
25000 |
|
- |
| 7.2.2(Tensile Strength) |
- |
25000 |
|
- |
| 7.2.3(Stress at 0.2% permanent strain) |
- |
25000 |
|
- |
| 7.2.4(Elongation after fracture) |
- |
25000 |
|
- |
| 7.2.5(Breaking Torque Test) |
- |
1500 |
|
- |
| 7.2.6(Strength under wedge loading) |
- |
25000 |
|
- |
| 7.2.7(Hardness) |
- |
25000 |
|
- |
|
31 Dec, 2026 |
- - |
| 4518 |
CSIR-Central Building Research Institute, Roorkee
| 9184204
| IS 550 : Part 1 (2014) |
Safes: Part 1 specification (Fifth Revision) |
- |
450000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl. 4 Table 1(CLASSIFICATIONS) |
- |
450000 |
|
450000 + GST for two hours |
| Cl. 5 Table 2(DIMENSIONS AND SIZES) |
- |
450000 |
|
450000 + GST for two hours |
| Cl. 5 Table 2(DIMENSIONS AND SIZES) |
- |
450000 |
|
450000 + GST for two hours |
| Cl. 5 Table 2(DIMENSIONS AND SIZES) |
- |
450000 |
|
450000 + GST for two hours |
| Cl. 5 Table 2(DIMENSIONS AND SIZES) |
- |
450000 |
|
450000 + GST for two hours |
| Cl. 5 Table 2(DIMENSIONS AND SIZES) |
- |
450000 |
|
450000 + GST for two hours |
| Cl. 5 Table 2(DIMENSIONS AND SIZES) |
- |
450000 |
|
450000 + GST for two hours |
| Cl. 5 Table 2(DIMENSIONS AND SIZES) |
- |
450000 |
|
450000 + GST for two hours |
| Cl. 5 Table 2(DIMENSIONS AND SIZES) |
- |
450000 |
|
450000 + GST for two hours |
| Cl. 5 Table 10(DIMENSIONS AND SIZES) |
- |
450000 |
|
450000 + GST for two hours |
| Cl. 5 Table 2(DIMENSIONS AND SIZES) |
- |
450000 |
|
450000 + GST for two hours |
| Cl. 5 Table 2(DIMENSIONS AND SIZES) |
- |
450000 |
|
450000 + GST for two hours |
| Cl. 5 Table 2(DIMENSIONS AND SIZES) |
- |
450000 |
|
450000 + GST for two hours |
| Cl. 5 Table 2(DIMENSIONS AND SIZES) |
- |
450000 |
|
450000 + GST for two hours |
| Cl. 5 Table 2(DIMENSIONS AND SIZES) |
- |
450000 |
|
450000 + GST for two hours |
| Cl. 5 Table 2(DIMENSIONS AND SIZES) |
- |
450000 |
|
450000 + GST for two hours |
| Cl. 6 Table 3(Material) |
- |
450000 |
|
450000 + GST for two hours |
| Cl. 7 (DESIGNATIONS) |
- |
450000 |
|
450000 + GST for two hours |
| Cl. 8.1(Body) |
- |
450000 |
|
450000 + GST for two hours |
| Cl. 8.3(Door) |
- |
450000 |
|
450000 + GST for two hours |
| Cl. 8.4.1(Hinges) |
- |
450000 |
|
450000 + GST for two hours |
| Cl. 8.4.2(Bolts) |
- |
450000 |
|
450000 + GST for two hours |
| Cl. 8.5 Table 3(Handles) |
- |
450000 |
|
450000 + GST for two hours |
| Cl. 8.6.1(Locks (Type)) |
- |
450000 |
|
450000 + GST for two hours |
| Cl. 8.6.1.1(Locks (Type)) |
- |
450000 |
|
450000 + GST for two hours |
| Cl. 8.6.2(Locks (Levers)) |
- |
450000 |
|
450000 + GST for two hours |
| Cl. 8.6.3(Tests for locks) |
- |
450000 |
|
450000 + GST for two hours |
| Cl. 8.6.4(Keys) |
- |
450000 |
|
450000 + GST for two hours |
| Cl. 8.6.5(Unpickability) |
- |
450000 |
|
450000 + GST for two hours |
| Cl. 8.6.6(Non-interchangeability) |
- |
450000 |
|
450000 + GST for two hours |
| Cl. 8.7(Automatic Relocking Device) |
- |
450000 |
|
450000 + GST for two hours |
| Cl. 9(INTERNAL FIXTURES) |
- |
450000 |
|
450000 + GST for two hours |
| Cl. 10(Painting) |
- |
450000 |
|
450000 + GST for two hours |
| Cl. 10(Painting) |
- |
450000 |
|
450000 + GST for two hours |
| Cl. 11.1(Marking of Safes) |
- |
450000 |
|
450000 + GST for two hours |
| Cl. 11.2( Marking on Keys) |
- |
450000 |
|
450000 + GST for two hours |
| Cl. 11.3(BIS Certification Marking) |
- |
450000 |
|
450000 + GST for two hours |
|
12 Mar, 2028 |
- - |
| 4519 |
Shiva Analyticals (India) Private Limited, Bengaluru
| 6121716
| IS 14543 (2024) |
Packaged Drinking Water Other than Packaged Natural Mineral Water Specification Third Revision |
- |
20000.00 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 5.3(Appearance) |
- |
200 |
|
- |
| 5.4/Annex D/i(P,P-DDT) |
- |
180 |
|
- |
| 5.4/Annex D/ii(Lindane) |
- |
180 |
|
- |
| 5.4/Annex D/iv(b-Endosulfan) |
- |
180 |
|
- |
| 5.4/Annex D/xvi(Dieldrin) |
- |
180 |
|
- |
| 5.4/Annex D/xvi(Aldrin) |
- |
180 |
|
- |
| 5.4/Annex D/i(O,P-DDT) |
- |
180 |
|
- |
| 5.4/Annex D/iv(a-Endosulfan) |
- |
180 |
|
- |
| 5.4/Annex D/iii(d-HCH) |
- |
180 |
|
- |
| 5.4/Annex D/i(O,P-DDD) |
- |
180 |
|
- |
| 5.4/Annex D/i(P,P-DDE) |
- |
180 |
|
- |
| 5.4/Annex D/i(O,P-DDE) |
- |
180 |
|
- |
| 5.4/Annex D/iii(a-HCH) |
- |
180 |
|
- |
| 5.4/Annex D/iii(β- HCH) |
- |
180 |
|
- |
| 5.4/Annex D/iv(Endosulfan sulfate) |
- |
180 |
|
- |
| 5.4/Annex D/i(P,P-DDD) |
- |
180 |
|
- |
| 5.4/Annex D/xii(Alachlor) |
- |
180 |
|
- |
| 5.4/Annex D/vii(Chlorpyrifos) |
- |
180 |
|
- |
| 5.4/Annex D/x(Butachlor) |
- |
180 |
|
- |
| 5.4/Annex D/vi(Ethion) |
- |
180 |
|
- |
| 5.4/Annex D/xiv(Methyl parathion) |
- |
180 |
|
- |
| 5.4/Annex D/xv(Malathion) |
- |
180 |
|
- |
| 5.4/Annex D/viii(Phorate) |
- |
180 |
|
- |
| 5.4/Annex D/v(Monochrotophos) |
- |
180 |
|
- |
| 5.4/Annex D/xiii(Atrazine) |
- |
180 |
|
- |
| 5.4/Annex D/viii(Phorate sulphoxide) |
- |
180 |
|
- |
| 5.4/Annex D/viii(Phorate sulfone) |
- |
180 |
|
- |
| 5.4/Annex D/xxvii(Methyl paraoxon) |
- |
180 |
|
- |
| 5.4/Annex D/xxviii(Malaoxon) |
- |
180 |
|
- |
| 5.4/Annex D/xi(Isoproturon) |
- |
180 |
|
- |
| 5.4/Annex D/ix(2,4 –D) |
- |
180 |
|
- |
| Cl-5.3, Table-1 (i)(Colour, true colour units, Max) |
- |
200 |
|
- |
| Cl-5.3, Table-1 (ii)(Odour) |
- |
200 |
|
- |
| Cl-5.3, Table-1 (iii)(Taste) |
- |
200 |
|
- |
| Cl-5.3, Table-1 (iv)(Turbidity, nephelometric turbidity unit (NTU), Max) |
- |
200 |
|
- |
| Cl-5.3, Table-1 (v)(Total dissolved solids, mg/l, Max) |
- |
200 |
|
- |
| Cl-5.3, Table-1 (vi)(pH) |
- |
200 |
|
- |
| Cl-5.3, Table-2 (i)(Barium (as Ba)) |
- |
200 |
|
- |
| Cl-5.3, Table-2 (ii)(Copper (as Cu)) |
- |
200 |
|
- |
| Cl-5.3, Table-2 (iii)(Iron (as Fe)) |
- |
200 |
|
- |
| Cl-5.3, Table-2 (iv)(Manganese (as Mn)) |
- |
200 |
|
- |
| Cl-5.3, Table-2 (v)(Nitrate (as NO3 )) |
- |
200 |
|
- |
| Cl-5.3, Table-2 (vi)(Nitrite (as NO2 )) |
- |
200 |
|
- |
| Cl-5.3, Table-2 (vii)(Fluoride (as F)) |
- |
200 |
|
- |
| Cl-5.3, Table-2 (viii)(Zinc (as Zn)) |
- |
200 |
|
- |
| Cl-5.3, Table-2 (ix)(Silver (as Ag)) |
- |
200 |
|
- |
| Cl-5.3, Table-2 (x)(Aluminium (as A1)) |
- |
200 |
|
- |
| Cl-5.3, Table-2 (xi)(Chloride (as Cl)) |
- |
200 |
|
- |
| Cl-5.3, Table-2 (xii)(Selenium (as Se)) |
- |
200 |
|
- |
| Cl-5.3, Table-2 (xiii)(Sulphate (as SO4 )) |
- |
200 |
|
- |
| Cl-5.3, Table-2 (xiv)(Alkalinity (as HCO3 )) |
- |
200 |
|
- |
| Cl-5.3, Table-2 (xv)(Calcium (as Ca)) |
- |
200 |
|
- |
| Cl-5.3, Table-2 (xvi)(Magnesium (as Mg)) |
- |
200 |
|
- |
| Cl-5.3, Table-2 (xvii)(Sodium (as Na)) |
- |
200 |
|
- |
| Cl-5.3, Table-2 (xviii)(Residual free chlorine) |
- |
200 |
|
- |
| Cl-5.3, Table-2 (xix)(Phenolic compounds (as C6H5OH)) |
- |
200 |
|
- |
| Cl-5.3, Table-2 (xx)(Mineral oil) |
- |
550 |
|
- |
| Cl-5.2.1(Escherichia coli or thermotolerant bacteria) |
- |
415 |
|
- |
| Cl-5.2.2(Coliform) |
- |
415 |
|
- |
| Cl-5.2.3(Staphylococcus aureus) |
- |
470 |
|
- |
| Cl-5.2.4(Sulphite Reducing Anaerobes) |
- |
415 |
|
- |
| Cl-5.2.5(Pseudomonas Aeruginosa) |
- |
415 |
|
- |
| Cl-5.2.6(Aerobic Microbial Count @ 37 deg C) |
- |
415 |
|
- |
| Cl-5.2.7(Yeast and mould) |
- |
415 |
|
- |
| Cl-5.2.8(Salmonella) |
- |
415 |
|
- |
| Cl-5.2.9(Vibrio cholera) |
- |
415 |
|
- |
| Cl-5.1(General Requirements) |
- |
200 |
|
- |
| 5.4 i)(Dieldrin) |
- |
180 |
|
- |
| 5.4 i)(Aldrin) |
- |
180 |
|
- |
| 5.4 i)(Malathion) |
- |
180 |
|
- |
| 5.4, i)("oxygen analogue of Malathion (Malaoxon)") |
- |
180 |
|
- |
| 5.4 i)(Methyl Paraoxon) |
- |
180 |
|
- |
| 5.4 i)(Methyl Parathion) |
- |
180 |
|
- |
| 5.4 i)(Atrazine) |
- |
180 |
|
- |
| 5.4 i)(Alachlor) |
- |
180 |
|
- |
| 5.4 i)(Isoproturon) |
- |
180 |
|
- |
| 5.4 i)(Butachlor) |
- |
180 |
|
- |
| 5.4 i)(2,4-D) |
- |
180 |
|
- |
| 5.4 i)(Phorate sulphone) |
- |
180 |
|
- |
| 5.4 i)(Phorate sulphoxide) |
- |
180 |
|
- |
| 5.4 i)(Phorate) |
- |
180 |
|
- |
| 5.4 i)(Chlorpyrifos) |
- |
180 |
|
- |
| 5.4 i)(Ethion) |
- |
180 |
|
- |
| 5.4 i)(Monocrotophos) |
- |
180 |
|
- |
| 5.4 i)(Endosulfan Sulphate) |
- |
180 |
|
- |
| 5.4 i)(beta-Endosulfan) |
- |
180 |
|
- |
| 5.4 i)(alpha-Endosulfan) |
- |
180 |
|
- |
| 5.4 i)(Delta-HCH) |
- |
180 |
|
- |
| 5.4 i)(beta-HCH) |
- |
180 |
|
- |
| 5.4 i)(alpha-HCH) |
- |
180 |
|
- |
| 5.4 i)(Gamma-HCH (Lindane)) |
- |
180 |
|
- |
| 5.4 i)(p,p DDD) |
- |
180 |
|
- |
| 5.4 i)(o,p DDD) |
- |
180 |
|
- |
| 5.4 i)(p,p DDE) |
- |
180 |
|
- |
| 5.4, i)(o,p DDE) |
- |
180 |
|
- |
| 5.4 i)(p,p DDT) |
- |
180 |
|
- |
| 5.4 i)(o,p DDT) |
- |
180 |
|
- |
| Table 3, x)(Uranium) |
- |
200 |
|
- |
| Cl-5.3, Table-3 (x)(Uranium) |
- |
200 |
|
- |
| Cl-5.2.3(Faecal streptococci) |
- |
415 |
|
- |
| Cl-5.2.8(shigella) |
- |
415 |
|
- |
| Cl-5.2.9(V.parahaemolyticus) |
- |
415 |
|
- |
| 5.2.6(Aerobic Microbial Count @ 20 to 22 deg C) |
- |
415 |
|
- |
| Cl-5.3, Table-2 (xxi)(Anionic surface active agents) |
- |
200 |
|
- |
| Cl-5.3, Table-2 (xxii)(Sulphide) |
- |
200 |
|
- |
| Cl-5.3, Table-2 (xxiii)(Antimony (as Sb)) |
- |
200 |
|
- |
| Cl-5.3, Table-2 (xxiv)(Borates (as B)) |
- |
200 |
|
- |
| Cl-5.3, Table-2 (xxv)(Bromates (as BrO3 )) |
- |
200 |
|
- |
| Cl-5.3, Table-3 (i)(Mercury (as Hg)) |
- |
200 |
|
- |
| Cl-5.3, Table-3 (ii)(Cadmium (as Cd)) |
- |
200 |
|
- |
| Cl-5.3, Table-3 (iii)(Arsenic (as As)) |
- |
200 |
|
- |
| Cl-5.3, Table-3 (iv)(Cyanide (as CN)) |
- |
200 |
|
- |
| Cl-5.3, Table-3 (v)(Lead (as Pb)) |
- |
200 |
|
- |
| Cl-5.3, Table-3 (vi)(Chromium (as Cr)) |
- |
200 |
|
- |
| Cl-5.3, Table-3 (viii)(Polychlorinated biphenyl (PCB)) |
- |
200 |
|
- |
| Cl-5.3, Table-3 (vii)(Nickel (as Ni)) |
- |
200 |
|
- |
| Cl-5.3, Table-3 (ix)(Polynuclear aromatic hydrocarbons) |
- |
200 |
|
- |
| Cl-5.4 (i)(Pesticide residues considered individually) |
- |
200 |
|
- |
| Cl-5.4 (ii)(Total pesticide residue) |
- |
200 |
|
- |
| Cl-5.3, Table-4 (i)(Alpha emitters, Becquerel (Bq/l)) |
- |
0.00 |
|
- |
| Cl-5.3, Table-4 (ii)(Beta emitters, Becquerel (Bq/l),) |
- |
0.00 |
|
- |
| 5.3(Appearance) |
- |
- |
|
- |
| 5.4/Annex D/i(P,P-DDT) |
- |
- |
|
- |
| 5.4/Annex D/ii(Lindane) |
- |
- |
|
- |
| 5.4/Annex D/iv(b-Endosulfan) |
- |
- |
|
- |
| 5.4/Annex D/xvi(Dieldrin) |
- |
- |
|
- |
| 5.4/Annex D/xvi(Aldrin) |
- |
- |
|
- |
| 5.4/Annex D/i(O,P-DDT) |
- |
- |
|
- |
| 5.4/Annex D/iv(a-Endosulfan) |
- |
- |
|
- |
| 5.4/Annex D/iii(d-HCH) |
- |
- |
|
- |
| 5.4/Annex D/i(O,P-DDD) |
- |
- |
|
- |
| 5.4/Annex D/i(P,P-DDE) |
- |
- |
|
- |
| 5.4/Annex D/i(O,P-DDE) |
- |
- |
|
- |
| 5.4/Annex D/iii(a-HCH) |
- |
- |
|
- |
| 5.4/Annex D/iii(β- HCH) |
- |
- |
|
- |
| 5.4/Annex D/iv(Endosulfan sulfate) |
- |
- |
|
- |
| 5.4/Annex D/i(P,P-DDD) |
- |
- |
|
- |
| 5.4/Annex D/xii(Alachlor) |
- |
- |
|
- |
| 5.4/Annex D/vii(Chlorpyrifos) |
- |
- |
|
- |
| 5.4/Annex D/x(Butachlor) |
- |
- |
|
- |
| 5.4/Annex D/vi(Ethion) |
- |
- |
|
- |
| 5.4/Annex D/xiv(Methyl parathion) |
- |
- |
|
- |
| 5.4/Annex D/xv(Malathion) |
- |
- |
|
- |
| 5.4/Annex D/viii(Phorate) |
- |
- |
|
- |
| 5.4/Annex D/v(Monochrotophos) |
- |
- |
|
- |
| 5.4/Annex D/xiii(Atrazine) |
- |
- |
|
- |
| 5.4/Annex D/viii(Phorate sulphoxide) |
- |
- |
|
- |
| 5.4/Annex D/viii(Phorate sulfone) |
- |
- |
|
- |
| 5.4/Annex D/xxvii(Methyl paraoxon) |
- |
- |
|
- |
| 5.4/Annex D/xxviii(Malaoxon) |
- |
- |
|
- |
| 5.4/Annex D/xi(Isoproturon) |
- |
- |
|
- |
| 5.4/Annex D/ix(2,4 –D) |
- |
- |
|
- |
| Cl-5.3, Table-1 (i)(Colour, true colour units, Max) |
- |
- |
|
- |
| Cl-5.3, Table-1 (ii)(Odour) |
- |
- |
|
- |
| Cl-5.3, Table-1 (iii)(Taste) |
- |
- |
|
- |
| Cl-5.3, Table-1 (iv)(Turbidity, nephelometric turbidity unit (NTU), Max) |
- |
- |
|
- |
| Cl-5.3, Table-1 (v)(Total dissolved solids, mg/l, Max) |
- |
- |
|
- |
| Cl-5.3, Table-1 (vi)(pH) |
- |
- |
|
- |
| Cl-5.3, Table-2 (i)(Barium (as Ba)) |
- |
- |
|
- |
| Cl-5.3, Table-2 (ii)(Copper (as Cu)) |
- |
- |
|
- |
| Cl-5.3, Table-2 (iii)(Iron (as Fe)) |
- |
- |
|
- |
| Cl-5.3, Table-2 (iv)(Manganese (as Mn)) |
- |
- |
|
- |
| Cl-5.3, Table-2 (v)(Nitrate (as NO3 )) |
- |
- |
|
- |
| Cl-5.3, Table-2 (vi)(Nitrite (as NO2 )) |
- |
- |
|
- |
| Cl-5.3, Table-2 (vii)(Fluoride (as F)) |
- |
- |
|
- |
| Cl-5.3, Table-2 (viii)(Zinc (as Zn)) |
- |
- |
|
- |
| Cl-5.3, Table-2 (ix)(Silver (as Ag)) |
- |
- |
|
- |
| Cl-5.3, Table-2 (x)(Aluminium (as A1)) |
- |
- |
|
- |
| Cl-5.3, Table-2 (xi)(Chloride (as Cl)) |
- |
- |
|
- |
| Cl-5.3, Table-2 (xii)(Selenium (as Se)) |
- |
- |
|
- |
| Cl-5.3, Table-2 (xiii)(Sulphate (as SO4 )) |
- |
- |
|
- |
| Cl-5.3, Table-2 (xiv)(Alkalinity (as HCO3 )) |
- |
- |
|
- |
| Cl-5.3, Table-2 (xv)(Calcium (as Ca)) |
- |
- |
|
- |
| Cl-5.3, Table-2 (xvi)(Magnesium (as Mg)) |
- |
- |
|
- |
| Cl-5.3, Table-2 (xvii)(Sodium (as Na)) |
- |
- |
|
- |
| Cl-5.3, Table-2 (xviii)(Residual free chlorine) |
- |
- |
|
- |
| Cl-5.3, Table-2 (xix)(Phenolic compounds (as C6H5OH)) |
- |
- |
|
- |
| Cl-5.3, Table-2 (xx)(Mineral oil) |
- |
- |
|
- |
| Cl-5.2.1(Escherichia coli or thermotolerant bacteria) |
- |
- |
|
- |
| Cl-5.2.2(Coliform) |
- |
- |
|
- |
| Cl-5.2.3(Staphylococcus aureus) |
- |
- |
|
- |
| Cl-5.2.4(Sulphite Reducing Anaerobes) |
- |
- |
|
- |
| Cl-5.2.5(Pseudomonas Aeruginosa) |
- |
- |
|
- |
| Cl-5.2.6(Aerobic Microbial Count @ 37 deg C) |
- |
- |
|
- |
| Cl-5.2.7(Yeast and mould) |
- |
- |
|
- |
| Cl-5.2.8(Salmonella) |
- |
- |
|
- |
| Cl-5.2.9(Vibrio cholera) |
- |
- |
|
- |
| Cl-5.1(General Requirements) |
- |
- |
|
- |
| 5.4 i)(Dieldrin) |
- |
- |
|
- |
| 5.4 i)(Aldrin) |
- |
- |
|
- |
| 5.4 i)(Malathion) |
- |
- |
|
- |
| 5.4, i)("oxygen analogue of Malathion (Malaoxon)") |
- |
- |
|
- |
| 5.4 i)(Methyl Paraoxon) |
- |
- |
|
- |
| 5.4 i)(Methyl Parathion) |
- |
- |
|
- |
| 5.4 i)(Atrazine) |
- |
- |
|
- |
| 5.4 i)(Alachlor) |
- |
- |
|
- |
| 5.4 i)(Isoproturon) |
- |
- |
|
- |
| 5.4 i)(Butachlor) |
- |
- |
|
- |
| 5.4 i)(2,4-D) |
- |
- |
|
- |
| 5.4 i)(Phorate sulphone) |
- |
- |
|
- |
| 5.4 i)(Phorate sulphoxide) |
- |
- |
|
- |
| 5.4 i)(Phorate) |
- |
- |
|
- |
| 5.4 i)(Chlorpyrifos) |
- |
- |
|
- |
| 5.4 i)(Ethion) |
- |
- |
|
- |
| 5.4 i)(Monocrotophos) |
- |
- |
|
- |
| 5.4 i)(Endosulfan Sulphate) |
- |
- |
|
- |
| 5.4 i)(beta-Endosulfan) |
- |
- |
|
- |
| 5.4 i)(alpha-Endosulfan) |
- |
- |
|
- |
| 5.4 i)(Delta-HCH) |
- |
- |
|
- |
| 5.4 i)(beta-HCH) |
- |
- |
|
- |
| 5.4 i)(alpha-HCH) |
- |
- |
|
- |
| 5.4 i)(Gamma-HCH (Lindane)) |
- |
- |
|
- |
| 5.4 i)(p,p DDD) |
- |
- |
|
- |
| 5.4 i)(o,p DDD) |
- |
- |
|
- |
| 5.4 i)(p,p DDE) |
- |
- |
|
- |
| 5.4, i)(o,p DDE) |
- |
- |
|
- |
| 5.4 i)(p,p DDT) |
- |
- |
|
- |
| 5.4 i)(o,p DDT) |
- |
- |
|
- |
| Table 3, x)(Uranium) |
- |
- |
|
- |
| Cl-5.3, Table-3 (x)(Uranium) |
- |
- |
|
- |
| Cl-5.2.3(Faecal streptococci) |
- |
- |
|
- |
| Cl-5.2.8(shigella) |
- |
- |
|
- |
| Cl-5.2.9(V.parahaemolyticus) |
- |
- |
|
- |
| 5.2.6(Aerobic Microbial Count @ 20 to 22 deg C) |
- |
- |
|
- |
| Cl-5.3, Table-2 (xxi)(Anionic surface active agents) |
- |
- |
|
- |
| Cl-5.3, Table-2 (xxii)(Sulphide) |
- |
- |
|
- |
| Cl-5.3, Table-2 (xxiii)(Antimony (as Sb)) |
- |
- |
|
- |
| Cl-5.3, Table-2 (xxiv)(Borates (as B)) |
- |
- |
|
- |
| Cl-5.3, Table-2 (xxv)(Bromates (as BrO3 )) |
- |
- |
|
- |
| Cl-5.3, Table-3 (i)(Mercury (as Hg)) |
- |
- |
|
- |
| Cl-5.3, Table-3 (ii)(Cadmium (as Cd)) |
- |
- |
|
- |
| Cl-5.3, Table-3 (iii)(Arsenic (as As)) |
- |
- |
|
- |
| Cl-5.3, Table-3 (iv)(Cyanide (as CN)) |
- |
- |
|
- |
| Cl-5.3, Table-3 (v)(Lead (as Pb)) |
- |
- |
|
- |
| Cl-5.3, Table-3 (vi)(Chromium (as Cr)) |
- |
- |
|
- |
| Cl-5.3, Table-3 (viii)(Polychlorinated biphenyl (PCB)) |
- |
- |
|
- |
| Cl-5.3, Table-3 (vii)(Nickel (as Ni)) |
- |
- |
|
- |
| Cl-5.3, Table-3 (ix)(Polynuclear aromatic hydrocarbons) |
- |
- |
|
- |
| Cl-5.4 (i)(Pesticide residues considered individually) |
- |
- |
|
- |
| Cl-5.4 (ii)(Total pesticide residue) |
- |
- |
|
- |
| Cl-5.3, Table-4 (i)(Alpha emitters, Becquerel (Bq/l)) |
- |
- |
|
- |
| Cl-5.3, Table-4 (ii)(Beta emitters, Becquerel (Bq/l),) |
- |
- |
|
- |
| 5.3/Table 2/xiii(Suphate) |
- |
- |
|
- |
|
21 Apr, 2028 |
- Included w.e.f.16.04.2025
Exclusion
Cl-5.3, Table-4 (i) (Alpha emitters, Becquerel (Bq/l))
Cl-5.3, Table-4 (ii) (Beta emitters, Becquerel (Bq/l),) |
| 4520 |
DELHI TEST HOUSE (50) KUNDLI SONIPAT
| 9127026
| IS 17980 (2022) |
Maximum Power Point Tracking Efficiency of Grid Connected Photovoltaic Inverters (First Revision) |
-- |
520000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl-4.1 (a)(Static MPPT efficiency) |
- |
260000 |
|
- |
| Cl-4.1 (b)(Dynamic MPPT efficiency) |
- |
260000 |
|
- |
|
23 Jun, 2028 |
- Included w.e.f.07.03.2025 |
| 4521 |
Atmy Analytical Labs Pvt. Ltd., Faridabad
| 8167506
| IS 17514 (2021) |
Reusable Sanitary PadSanitary Napkin Period panties Specification |
- |
15900 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 3.1(Material- Cover/Top sheet) |
- |
0 |
|
- |
| 3.2(Material- Absorbent Core) |
- |
0 |
|
- |
| 3.3(Material- Bottom Layer) |
- |
0 |
|
- |
| 4.0(Manufacturing , workmanship and finish) |
- |
0 |
|
- |
| 5.0(Fastening Mechanism) |
- |
0 |
|
- |
| 6.0(Sizes:- Pad Length and Pad Width (For Absorbent core only)) |
- |
0 |
|
- |
| 7.0(Washing , Drying And Handling Instruction) |
- |
0 |
|
- |
| 8 & 11.2.4, Table 1, (i)(Colour Fastness to Rubbing) |
- |
0 |
|
- |
| Cl-9.5(Phthalate Test) |
- |
0 |
|
- |
| 8 & 11.2.4, Table 1, (ii)(Colour Fastness to Perspiration (Acidic & Alkaline)) |
- |
0 |
|
- |
| 8 & 11.2.4, Table 1, (iii)(Colour Fastness to Washing) |
- |
0 |
|
- |
| 8 & 11.2.4, Table 1, (iv)(Dimensional Stability to washing, percentage) |
- |
0 |
|
- |
| 9.1(pH Value) |
- |
0 |
|
- |
| 9.2(Ability to Withstand Pressure after Absorption) |
- |
0 |
|
- |
| 9.3.1(Bacterial and Fungal Bioburden) |
- |
0 |
|
- |
| 9.3.2(Test for Common Skin Pathogen -Staphylococcus Aureus) |
- |
0 |
|
- |
| 12.0(Marking & Packing) |
- |
0 |
|
- |
| 13.0(Marking & Packing) |
- |
0 |
|
- |
| Clause No. 6(Pad length and width) |
- |
0 |
|
- |
| Clause No. 8, Table No. 1, (i)(Colour fastness to rubbing of fabric) |
- |
0 |
|
- |
| Clause No. 8, Table No. 1, (ii)(Colour fastness to perspiration (acidic and alkaline)) |
- |
0 |
|
- |
| Clause No. 8, Table No. 1, (iii)(Colour fastness to washing) |
- |
0 |
|
- |
| Clause No. 8, Table No. 1, (iv)(Dimensional stability to washing, length and width) |
- |
0 |
|
- |
| Clause No. 9.1(pH Value) |
- |
0 |
|
- |
| Clause No. 9.2(Ability to Withstand Pressure after Absorption) |
- |
0 |
|
- |
| Clause No. 9.3(Hygiene Testing Requirement) |
- |
0 |
|
- |
| Clause No. 9.3.1(Bacterial and Fungal Bioburden) |
- |
0 |
|
- |
| Clause No. 9.3.2(Test for Common Skin Pathogen — Staphylococcus Aureus) |
- |
0 |
|
- |
| Clause No. 9.4(Biocompatibility Evaluation — Cytotoxicity, Irritation and Skin Sensitization) |
- |
0 |
|
- |
| Clasue No. 10(Anti-Bacterial Activity Value) |
- |
0 |
|
- |
| 9.1(pH of Aqueous extract) |
- |
0 |
|
- |
| 9.5(Phthalate Test: Di-n-butyl phthalate (DBP)) |
- |
0 |
|
- |
| 9.5(Phthalate Test: Benzyl butyl phthalate (BBP)) |
- |
0 |
|
- |
| 9.5(Phthalate Test: Bis- (2-ethylhexyl) phthalate (DEHP)) |
- |
0 |
|
- |
| 9.5(Phthalate Test: di-n-octyl phtahlate (DNOP)) |
- |
0 |
|
- |
| 9.5(Phthalate Test: Di-iso-nonyl phthalate (DINP)) |
- |
0 |
|
- |
| 9.5(Phthalate Test: Di-iso-decyl phthalate (DIDP)) |
- |
0 |
|
- |
|
25 Feb, 2027 |
- Included w.e.f 04.06.2025 |
| 4522 |
Atmy Analytical Labs Pvt. Ltd., Faridabad
| 8167506
| IS 17509 (2021) |
Disposable Baby Diaper Specification |
- |
21000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Clause no. 3(Material) |
- |
0 |
|
- |
| Clause no. 3.1(Top Cover / Top Sheet) |
- |
0 |
|
- |
| Clause no. 3.2(Absorbent Core) |
- |
0 |
|
- |
| Clause no. 3.3(Outer Protective Barrier or Back Sheet) |
- |
0 |
|
- |
| Clause no. 4(Fastening & Securing Mechanism) |
- |
0 |
|
- |
| Clause no. 5(ManufactureWorkmanship and Finish) |
- |
0 |
|
- |
| Clause no.6(Type and Size: FOR X LARGE) |
- |
0 |
|
- |
| Clause no.6(Diaper Length) |
- |
0 |
|
- |
| Clause no.6(Diaper Width) |
- |
0 |
|
- |
| Clause no.6(Diaper Crotch) |
- |
0 |
|
- |
| Clause no.6(Absorbent Core Length) |
- |
0 |
|
- |
| Clause no.6(Absorbent Core Width Back) |
- |
0 |
|
- |
| 1() |
- |
0 |
|
- |
| Clause no.6(Absorbent Core Length) |
- |
0 |
|
- |
| Clause no.6(Absorbent Core Width Front) |
- |
0 |
|
- |
| Clause no.6(Core Cortch) |
- |
0 |
|
- |
| Clause no.7(Performance Requirements) |
- |
0 |
|
- |
| Clause no.7.1(pH Value) |
- |
0 |
|
- |
| Clause no.7.2 Table-2(Minimum absorption Capacity (X Large)) |
- |
0 |
|
- |
| Clause no.7.2 Table-2(Rewet under Load (All Sizes)) |
- |
0 |
|
- |
| Clause no.7.2 Table-2(Rate of Absorption (All Sizes)) |
- |
0 |
|
- |
| Clause no.7.3(Hygiene Testing Requirement, Total Viable Count) |
- |
0 |
|
- |
| Clause no.7.3(Hygiene Testing Requirement, Staphylococcus Aureus) |
- |
0 |
|
- |
| Clause no.7.4(Biocompatibility Evaluation- Cytotoxicity) |
- |
0 |
|
- |
| Clause no. 7.4(Biocompatibility Evaluation- Irritation) |
- |
0 |
|
- |
| Clause no.7.4(Biocompatibility Evaluation- Skin Sensitization) |
- |
0 |
|
- |
| Clause no.7.5(Phthalate Test) |
- |
0 |
|
- |
| Clause no.7.6(Biodegradability and Compostability (optional)) |
- |
0 |
|
- |
| Clause no.7.7(Anti-Bacterial Activity Value (optional)) |
- |
0 |
|
- |
| 9 & 9.1(Marking) |
- |
0 |
|
- |
| 10(Packing) |
- |
0 |
|
- |
| CL 7.3(Total Viable Count) |
- |
0 |
|
- |
| CL 7.3(Staphylococcus aureus) |
- |
0 |
|
- |
| CL 7.4(Biocompatibility Evaluation - Cytotoxicity, Irritation and Skin Sensitization) |
- |
0 |
|
- |
| CL 7.6(Biodegradability and Compostability (Optional)) |
- |
0 |
|
- |
| CL 7.7(Anti-Bacterial Activity Value (Optional)) |
- |
0 |
|
- |
| 6.2(Type and Sizes) |
- |
0 |
|
- |
|
25 Feb, 2027 |
- Included w.e.f 04.06.2025 |
| 4523 |
Atmy Analytical Labs Pvt. Ltd., Faridabad
| 8167506
| IS 5405 (2019) |
Sanitary napkins – Specification (second revision) |
- |
15900 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl 5(SIZES, Regular ) |
- |
0 |
|
- |
| Cl 5(SIZES, Large) |
- |
0 |
|
- |
| Cl 5(SIZES, Extra Large) |
- |
0 |
|
- |
| Cl 5(SIZES, XXL) |
- |
0 |
|
- |
| Cl 5(Absorbent Capacity, Regular ) |
- |
0 |
|
- |
| Cl 5(Absorbent Capacity, Large) |
- |
0 |
|
- |
| Cl 5(Absorbent Capacity, Extra Large) |
- |
0 |
|
- |
| Cl 5(Absorbent Capacity, XXL) |
- |
0 |
|
- |
| Cl 7.1(pH Value, IS 1390 (cold method) for all sizes) |
- |
0 |
|
- |
| Cl 7.2(Ability to Withstand Pressure after Absorption, for all sizes, Annex B) |
- |
0 |
|
- |
| Cl 7.3.1(Bacterial and Fungal Bioburden, 7.3.1.1, ISO 11737 (Part 1)) |
- |
0 |
|
- |
| Cl7.3.2(Test for Common Skin Pathogen — Staphylococcus
Aureus, 7.3.2.1, IS 5887 (Part 2)) |
- |
0 |
|
- |
| Cl 7.4(Biocompatibility Evaluation — Cytotoxicity,
Irritation and Skin Sensitization, IS/ISO 10993 Part 5
and IS/ISO 10993 Part 10) |
- |
0 |
|
- |
| Cl 7.5(Biodegradability and Compostability
(Optional), IS/ISO 17088.) |
- |
0 |
|
- |
| Cl 5(SIZES, Regular ) |
- |
0 |
|
- |
| Cl 5(SIZES, Large) |
- |
0 |
|
- |
| Cl 5(SIZES, Extra Large) |
- |
0 |
|
- |
| Cl 5(SIZES, XXL) |
- |
0 |
|
- |
| Cl 5(Absorbent Capacity, Regular ) |
- |
0 |
|
- |
| Cl 5(Absorbent Capacity, Large) |
- |
0 |
|
- |
| Cl 5(Absorbent Capacity, Extra Large) |
- |
0 |
|
- |
| Cl 5(Absorbent Capacity, XXL) |
- |
0 |
|
- |
| Cl 7.1(pH Value, IS 1390 (cold method) for all sizes) |
- |
0 |
|
- |
| Cl 7.2(Ability to Withstand Pressure after Absorption, for all sizes, Annex B) |
- |
0 |
|
- |
| Cl 7.3.1(Bacterial and Fungal Bioburden, 7.3.1.1, ISO 11737 (Part 1)) |
- |
0 |
|
- |
| Cl7.3.2(Test for Common Skin Pathogen — Staphylococcus
Aureus, 7.3.2.1, IS 5887 (Part 2)) |
- |
0 |
|
- |
| Cl 7.4(Biocompatibility Evaluation — Cytotoxicity,
Irritation and Skin Sensitization, IS/ISO 10993 Part 5
and IS/ISO 10993 Part 10) |
- |
0 |
|
- |
| Cl 7.5(Biodegradability and Compostability
(Optional), IS/ISO 17088.) |
- |
0 |
|
- |
| 3.1(Cover/Top sheet) |
- |
0 |
|
- |
| 3.2(Absorbent Core) |
- |
0 |
|
- |
| 3.3(Barrier or Bottom Sheet) |
- |
0 |
|
- |
| 4.1 (1)(Type and shapes of sanitary napkins) |
- |
0 |
|
- |
| 4.2(Sanitary napkins shape & design) |
- |
0 |
|
- |
| 6.0(Manufacture, workmanship & finish) |
- |
0 |
|
- |
| CL 7.4(Biocompatibility Evaluation - Cytotoxicity, Irritation and Skin Sensitization (Optional)) |
- |
0 |
|
- |
| CL 7.5(Compostability or Biodegradability during Composting (Optional)) |
- |
0 |
|
- |
| 7.6(Pthalate test) |
- |
0 |
|
- |
|
25 Feb, 2027 |
- Included w.e.f 04.06.2025 |
| 4524 |
Electronic Safety Test Laboratory, EMC Division, SAMEER-Centre for Microwave Research
| 7192524
| IS 13252 : Part 1 (2010) |
Information technology equipment - Safety: Part 1 general requirements (Second Revision) |
- |
109300 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 1.5(Components) |
- |
3500 |
|
- |
| 1.6(Power interface .) |
- |
4900 |
|
- |
| 1.7(Markings and instructions) |
- |
2900 |
|
- |
| 2.1(Protection from electric shock and energy hazards) |
- |
20100 |
|
- |
| 2.2(SELV circuits) |
- |
3500 |
|
- |
| 2.3(TNV circuits) |
- |
3600 |
|
- |
| 2.4(Limited current circuits) |
- |
4900 |
|
- |
| 2.5(Limited power sources .) |
- |
4700 |
|
- |
| 2.6(Provisions for earthing and bonding) |
- |
6500 |
|
- |
| 2.9(Electrical insulation) |
- |
0 |
|
Depending upon Numbers of test day |
| 2.10(Clearances, creepage distances and distances through insulation) |
- |
54500 |
|
- |
| 3.1(General) |
- |
6500 |
|
- |
| 3.2(Connection to a mains supply) |
- |
3900 |
|
- |
| 4.1(Stability) |
- |
3300 |
|
- |
| 4.2(Mechanical strength) |
- |
16900 |
|
- |
| 4.3(Design and construction) |
- |
6300 |
|
- |
| 4.4(Protection against hazardous moving parts) |
- |
2900 |
|
- |
| 4.5(Thermal requirements) |
- |
12500 |
|
- |
| 4.6(Openings in enclosures) |
- |
2900 |
|
- |
| 4.7(Resistance to fire) |
- |
7400 |
|
- |
| 5.1(Touch current and protective conductor curren) |
- |
4200 |
|
- |
| 5.2(Electric strength) |
- |
3600 |
|
- |
| 5.3(Abnormal operating and fault conditions) |
- |
6800 |
|
- |
| 6.1(Protection of telecommunication network service persons, and users of other equipment connected to the network, from hazards in the equipment) |
- |
3600 |
|
- |
| 6.2(Protection of equipment users from overvoltages on networks telecommunication) |
- |
6000 |
|
- |
| 6.3(Protection of the telecommunication wiring system from overheating) |
- |
4600 |
|
- |
| 7.1(General) |
- |
0 |
|
- |
| 7.2(Protection of cable distribution system service persons, and users of other equipment connected to the system, from hazardous voltages in the equipment) |
- |
0 |
|
- |
| 7.3(Protection of equipment users from overvoltages on the cable distribution system) |
- |
6100 |
|
- |
| 7.4(Insulation between primary circuits and cable distribution systems) |
- |
11200 |
|
- |
| 2.8.2/2.8.5(Interlock switches) |
- |
0 |
|
- |
| 2.8.7(Switches and Relay) |
- |
0 |
|
- |
| 2.10.4.2(Material Group and Comparative Tracking Index) |
- |
3500 |
|
- |
| 2.10.5.3(Insulating Compound as Solid Insulation) |
- |
3600 |
|
- |
| 2.10.5.6(Thin sheet materials) |
- |
3600 |
|
- |
| 2.10.6(PCB material) |
- |
0 |
|
- |
| 2.10.8.4(Abrasion resistance test) |
- |
3700 |
|
- |
| 2.10.9(Thermal Cycling) |
- |
7700 |
|
Depends on numbers of test day |
| 3.1.4(Internal wire) |
- |
3500 |
|
- |
| 3.2.4(Appliance inlet /connector) |
- |
3000 |
|
- |
| 3.2.4(Appliance inlet /connector) |
- |
3000 |
|
- |
| 4.3.8(Batteries) |
- |
0 |
|
- |
| 4.3.10(Dust, powders, liquids and gases) |
- |
0 |
|
- |
| 3.2.5(Non re-wirable plug with PVC sheathed cable) |
- |
0 |
|
- |
| 4.3.13.5(LED, laser class) |
- |
0 |
|
- |
| Annex U(Insulating winding wires for use without interleaved insulation) |
- |
3700 |
|
U.2.3 (flexibility and adherence )not possible ,
Charges depends on numbers of test day |
| Annex CC(Evaluation of integrated circuit (IC) current limiters) |
- |
6800 |
|
Depends on numbers of test day |
| Annex K(Thermal Control) |
- |
5400 |
|
- |
| 1.5(Components) |
- |
3500 |
|
- |
| Annex B(Motor tests under abnormal conditions) |
- |
5400 |
|
- |
| Annex C(Transformers) |
- |
5400 |
|
- |
| Annex DD(Requirements for the mounting means of a rack mounted equipment) |
- |
3000 |
|
- |
| 4.6.2(Bottoms of fire enclosures) |
- |
0 |
|
- |
| 2.10.5.4(Opto-coupler) |
- |
7000 |
|
- |
| 3.3(Wiring terminals for connection of external conductors) |
- |
3000 |
|
- |
| 3.4(Disconnection from the mains supply) |
- |
0 |
|
- |
| 3.5(Interconnection of equipment) |
- |
0 |
|
- |
| 2.7(Overcurrent and earth fault protection in primary circuits) |
- |
3600 |
|
- |
| 2.8(Safety interlocks) |
- |
0 |
|
- |
| 2.10.8.2(Thermal conditioning (thermal ageing)) |
- |
3000 |
|
Depends of Numbers of test day |
|
04 Dec, 2028 |
- Exclusion: 2.8 (Safety interlocks)
2.10.5.11 (SMPS Transformer and Inductor)
2.10.5.12 (Wires in wound components)
2.10.5.13 (Winding wire)
2.10.5.14 (Additional insulation in wound components)
2.10.10 (Test for Pollution Degree 1 environment and for insulating compound)
2.10.11 (Tests for semiconductor devices and for cemented joints)
2.10.12 (Enclosed and sealed parts)
4.2.8 (Cathode Ray Tubes)
4.3.11 (Containers for liquids or gases)
4.3.12 (Flammable liquids)
4.3.13.2 (Ionizing radiation)
4.3.13.3/ Annex Y (Effect of UV radiation on material/Ultraviolet conditioning test)
4.3.13.4 (Human exposure to ultraviolet (UV) radiation)
Annex Q (Voltage Dependent Resistors)
Annex A3 (Hot flaming oil test) |
| 4525 |
ALPHA TEST HOUSE PVT LTD, BAHADURGARH
| 8185306
| IS 17264 (2022) |
Textiles - Polyester industrial yarn - Specification (first revision) |
- |
46500 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4(Designation of Yarn (IS 17264)) |
- |
7500 |
|
- |
| 1(Microscopic and dissolution (IS 667)) |
- |
40000 |
|
- |
| 5.2.1 a(melting point) |
- |
2500 |
|
- |
| 5.2.1 b(Staining Test (IS 667)) |
- |
3500 |
|
- |
| 5.2.2 & Table-1(Classification (IS 17264)) |
- |
1500 |
|
- |
| 5.2.2 & Table-1(Identification) |
- |
40000 |
|
- |
| 6.3(Freedom from defects (IS 17264)) |
- |
3500 |
|
- |
| 6.1 & Table-3(Linear Density (IS 7703 Part-1)) |
- |
2500 |
|
- |
| 6.1 & Table-3(Tenacity (IS 7703 Part-2)) |
- |
2500 |
|
- |
| 6.1 & Table-3(Elongation (IS 7703 Part-2)) |
- |
2500 |
|
- |
| 6.1 & Table-3(Hot Air Shrinkage (IS 17264)) |
- |
2500 |
|
- |
| 6.2 & Table-4(Moisture regain (IS 17264)) |
- |
2000 |
|
- |
| 6.2 & Table-4(Isophthalic acid (IPA) content (IS 16481)) |
- |
2500 |
|
- |
| 6.2 & Table-4(Water soluble matter (IS 3456)) |
- |
2500 |
|
- |
| 6.2 & Table-4(Finish oil pick-up (IS 17264)) |
- |
2500 |
|
- |
| 6.2 & Table-4(Phosphorus content (IS 17264)) |
- |
2500 |
|
- |
| 6.2 & Table-4(Ultraviolet resistance (IS 13162 Part-2)) |
- |
40000 |
|
- |
| 6.2 & Table-4(Colour strength with reference to standard yarn (IS 17264)) |
- |
2500 |
|
- |
| 6.2 & Table-4(Colour difference with reference to standard yarn, measured as ΔE (IS 17264)) |
- |
2500 |
|
- |
| 6.4 & Table-5(Colour Fastness Rating to light (IS/ISO 105-B01)) |
- |
7500 |
|
- |
| 6.4 & Table-5(Colour Fastness Rating to Rubbing (IS/ISO 105-X12)) |
- |
3500 |
|
- |
| 8(Marking (IS 17264)) |
- |
0 |
|
- |
| 6.6 & Table-6(Free and releasable formaldehyde (IS 14563 Part-1 & 2)) |
- |
9500 |
|
- |
| 6.6 & Table-6(Mercury (IS 15651)) |
- |
0 |
|
- |
| 6.6 & Table-6(Chromium III (IS 15651)) |
- |
0 |
|
- |
| 6.6 & Table-6(Chromium VI (IS 15651)) |
- |
0 |
|
- |
| 6.6 & Table-6(Lead (IS 15651)) |
- |
0 |
|
- |
| 6.6 & Table-6(Cadmium (IS 15651)) |
- |
0 |
|
- |
| 6.6 & Table-6(Copper (IS 15651)) |
- |
0 |
|
- |
| 6.6 & Table-6(Antimony (IS 15651)) |
- |
0 |
|
- |
| 6.6 & Table-6(Pesticides (sum parameter) (IS 15651)) |
- |
0 |
|
- |
| 6.6 & Table-6(Banned pesticides (IS 15651)) |
- |
0 |
|
- |
| 6.6 & Table-6(Banned azo colourants (arylamines) (IS 15570)) |
- |
0 |
|
- |
| 5.2(Identification and Description, Annex J of IS 16481 & IS 667) |
- |
40000 |
|
- |
| 6.4- Table -5, Sl no. 2 (a)(Rubbing, Dry IS/ISO 105-X12) |
- |
3500 |
|
- |
| 6.4- Table -5, Sl no. 2 (b)(Rubbing, Wet IS/ISO 105-X13) |
- |
3500 |
|
- |
| 6.5(Commercial mass) |
- |
2500 |
|
- |
| 6.2 Table 4(Finish Oil Pickup) |
- |
2500 |
|
- |
| 6.2 Table 4(Phosporus content) |
- |
2500 |
|
- |
| 6.2 Table 4(Colour strength with reference to std yarn %) |
- |
2500 |
|
- |
| 6.4 Table 5(Colour Fastness to Rubbing) |
- |
3500 |
|
- |
| 6.1 Table 3(Linear Density, Denier (dtex)) |
- |
2500 |
|
- |
| 6.1 Table 3(Tenacity,gpd (cN/dtex)) |
- |
2500 |
|
- |
| 6.1 Table 3(Elongation %) |
- |
2500 |
|
- |
| 6.1 Table 3(Hot Air Shrinkage %) |
- |
2500 |
|
- |
| 6.6 & Table-6(Pentachlorophenol (IS 15651)) |
- |
0 |
|
- |
|
08 May, 2028 |
- - |
| 4526 |
BIS, Western Regional Laboratory (WRL)
| None
| IS 13098 (2024) |
AUTOMOTIVE VEHICLES TUBES FOR PNEUMATIC TYRES â SPECIFICATION (second revision) |
- |
- View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl 6 (MARKING) |
- |
|
|
|
| Cl 5 (AIR TIGHTNESS) |
- |
|
|
|
| Cl 4.1.4 (Accelerated Ageing) |
- |
|
|
|
| Cl 4.1.3 (Set After Ageing) |
- |
|
|
|
| Cl 4.1.2 (Strength of Splice) |
- |
|
|
|
| Cl 4.1.1 (Elongation) |
- |
|
|
|
| Cl 3.3.1 (Thickness Uniformity) |
- |
|
|
|
| Cl 3.3 (Fit) |
- |
|
|
|
| Cl 3.2 (Classification) |
- |
|
|
|
| Cl 3.1 (Materials) |
- |
|
|
|
|
- |
- - |
| 4527 |
Alpha Test House Services LLP (160), Sahibzada Ajit Singh Nagar
| 9138706
| IS 15961 (2012) |
Hot dip aluminium - Zinc alloy metallic coated steel strip and sheet (Plain) |
All |
9500 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl 8(UTM) |
- |
9500 |
|
- |
| Cl 9 & Table 2(Workmanship) |
- |
9500 |
|
- |
| Cl 10(Coating Adhesion ) |
- |
9500 |
|
- |
| Cl 11(Workmanship) |
- |
9500 |
|
- |
| Cl 12(Weight) |
- |
9500 |
|
- |
| Cl 13(Length, Width, Thickness, Camber, Deviation From Squareness & Deviation From Flatness) |
- |
9500 |
|
- |
| Cl 8(UTM) |
- |
9500 |
|
- |
| Cl 9 & Table 2(Workmanship) |
- |
9500 |
|
- |
| Cl 10(Coating Adhesion ) |
- |
9500 |
|
- |
| Cl 11(Workmanship) |
- |
9500 |
|
- |
| Cl 12(Weight) |
- |
9500 |
|
- |
| Cl 13(Length, Width, Thickness, Camber, Deviation From Squareness & Deviation From Flatness) |
- |
9500 |
|
- |
| Cl 8(UTM) |
- |
9500 |
|
- |
| Cl 9 & Table 2(Workmanship) |
- |
9500 |
|
- |
| Cl 10(Coating Adhesion ) |
- |
9500 |
|
- |
| Cl 11(Workmanship) |
- |
9500 |
|
- |
| Cl 12(Weight) |
- |
9500 |
|
- |
| Cl 13(Length, Width, Thickness, Camber, Deviation From Squareness & Deviation From Flatness) |
- |
9500 |
|
- |
| Cl. 13.7(Deviation from Flatness (Steepness)) |
- |
9500 |
|
- |
| Cl. 13.6(Deviation from Squareness (Out of Square)) |
- |
9500 |
|
- |
| Cl. 13.5(Camber) |
- |
9500 |
|
- |
| Cl. 13.4(Thickness) |
- |
9500 |
|
- |
| Cl. 13.3(Width) |
- |
9500 |
|
- |
| 4, 5(CARBON) |
- |
9500 |
|
- |
| 4, 5(SULPHUR) |
- |
9500 |
|
- |
| 4, 5(PHOSPHURS) |
- |
9500 |
|
- |
| 4.5(MANGANESE) |
- |
9500 |
|
- |
| 4, 5(NITROGEN) |
- |
9500 |
|
- |
| 4, 5(SILICON) |
- |
9500 |
|
- |
| 4, 5(ALUMINIUM) |
- |
9500 |
|
- |
| Cl 13(Length, Width, Thickness, Camber, Deviation From Squareness & Deviation From Flatness) |
- |
9500 |
|
- |
| Cl 12(Weight) |
- |
9500 |
|
- |
| Cl 11(Workmanship) |
- |
9500 |
|
- |
| Cl 10(Coating Adhesion ) |
- |
9500 |
|
- |
| Cl 9 & Table 2(Workmanship) |
- |
9500 |
|
- |
| Cl 8(UTM) |
- |
9500 |
|
- |
| Cl 8(UTM) |
- |
9500 |
|
- |
| Cl 9 & Table 2(Workmanship) |
- |
9500 |
|
- |
| Cl 10(Coating Adhesion) |
- |
9500 |
|
- |
| Cl 11(Workmanship) |
- |
9500 |
|
- |
| Cl 12(Weight) |
- |
9500 |
|
- |
| Cl 13(Length, Width, Thickness, Camber, Deviation From Squareness & Deviation From Flatness) |
- |
9500 |
|
- |
| Clause 3.5(IS 15961) |
- |
9500 |
|
- |
| Clause 8, Table 1(IS 1608 Part 1) |
- |
9500 |
|
- |
| Clause 8, Table 1(IS 1608 Part 1) |
- |
9500 |
|
- |
| Clause 8, Table 1(IS 1608 Part 1) |
- |
9500 |
|
- |
| Clause 9(IS 15961) |
- |
9500 |
|
- |
| Clause 9(IS 15961) |
- |
9500 |
|
- |
| Clause 9(IS 15961) |
- |
9500 |
|
- |
| Clause 9.7(IS 15961) |
- |
9500 |
|
- |
| Clause 11(IS 15961) |
- |
9500 |
|
- |
| Clause 12(IS 15961) |
- |
9500 |
|
- |
| Clause 13.1(IS 15961) |
- |
9500 |
|
- |
| Clause 13.2(IS 15961) |
- |
9500 |
|
- |
| Clause 7.1(Any Instrumental Method/Chemical Method) |
- |
9500 |
|
- |
| Clause 7.1(Any Instrumental Method/Chemical Method) |
- |
9500 |
|
- |
| Clause 7.1(Any Instrumental Method/Chemical Method) |
- |
9500 |
|
- |
| Clause 7.1(Any Instrumental Method/Chemical Method) |
- |
9500 |
|
- |
| Clause 7.1(Any Instrumental Method/Chemical Method) |
- |
9500 |
|
- |
| Clause 7.1(Any Instrumental Method/Chemical Method) |
- |
9500 |
|
- |
| Clause 7.1(Any Instrumental Method/Chemical Method) |
- |
9500 |
|
- |
| Clause 7.1(Any Instrumental Method/Chemical Method) |
- |
9500 |
|
- |
| Clause 7.1(By Calculation) |
- |
9500 |
|
- |
| 7.1(Chemical composition %, IS 513) |
- |
9500 |
|
- |
| 8.0 (Table No.- 1)(Tensile Test MPa(T.S., Y.S. & El) - IS 1608) |
- |
9500 |
|
- |
| 9.0 (Table No.- 2)(Coating test, g/m2) |
- |
9500 |
|
- |
| 10.0 (Table No.-3)(Coating adhesion test) |
- |
9500 |
|
- |
| 11(Freedom from defects) |
- |
9500 |
|
- |
| 12(Mass, kg) |
- |
9500 |
|
- |
| 13(Dimensions, Shape and Tolerances,mm-IS/ISO 16163) |
- |
9500 |
|
- |
| 7.1(Chemical composition %, IS 513) |
- |
9500 |
|
- |
| 8.0 (Table No.- 1)(Tensile Test MPa(T.S., Y.S. & El) - IS 1608) |
- |
9500 |
|
- |
| 9.0 (Table No.- 2)(Coating test, g/m2) |
- |
9500 |
|
- |
| 10.0 (Table No.-3)(Coating adhesion test) |
- |
9500 |
|
- |
| 11(Freedom from defects) |
- |
9500 |
|
- |
| 12(Mass, kg) |
- |
9500 |
|
- |
| 13(Dimensions, Shape and Tolerances,mm-IS/ISO 16163) |
- |
9500 |
|
- |
| 7.1(Chemical composition %, IS 513) |
- |
9500 |
|
- |
| 8.0 (Table No.- 1)(Tensile Test MPa(T.S., Y.S. & El) - IS 1608) |
- |
9500 |
|
- |
| 9.0 (Table No.- 2)(Coating test, g/m2) |
- |
9500 |
|
- |
| 10.0 (Table No.-3)(Coating adhesion test) |
- |
9500 |
|
- |
| 11(Freedom from defects) |
- |
9500 |
|
- |
| 12(Mass, kg) |
- |
9500 |
|
- |
| 13(Dimensions, Shape and Tolerances,mm-IS/ISO 16163) |
- |
9500 |
|
- |
| Clause 3.5(Surface Finish) |
- |
9500 |
|
- |
| Clause 8, Table 1(Tensile Strength) |
- |
9500 |
|
- |
| Clause 8, Table 1(Yield Strength) |
- |
9500 |
|
- |
| Clause 8, Table 1(Elongation) |
- |
9500 |
|
- |
| Clause 9(Coating Test (Triple Spot Test) (Total Both Surface)) |
- |
9500 |
|
- |
| Clause 9(Coating Test (Triple Spot Test) (Total Both Surface)) |
- |
9500 |
|
- |
| Clause 9(Coating Test (Single Spot Test) (Total Both Surface)) |
- |
9500 |
|
- |
| Clause 9(Coating Test (Single Spot Test) (One Surface)) |
- |
9500 |
|
- |
| Clause 9.7(Differential Coating) |
- |
9500 |
|
- |
| Clause 11(Freedom from Defect) |
- |
9500 |
|
- |
| Clause 12(Mass) |
- |
9500 |
|
- |
| Clause 13.1(Coil Internal Diameter) |
- |
9500 |
|
- |
| Clause 13.2(Length Tolerance) |
- |
9500 |
|
- |
| Clause 7.1(Chromium) |
- |
9500 |
|
- |
| Clause 7.1(Nickel) |
- |
9500 |
|
- |
| Clause 7.1(Niobium) |
- |
9500 |
|
- |
| Clause 7.1(Vanadium) |
- |
9500 |
|
- |
| Clause 7.1(Titanium) |
- |
9500 |
|
- |
| Clause 7.1(Molybdenum) |
- |
9500 |
|
- |
| Clause 7.1(Boron) |
- |
9500 |
|
- |
| Clause 7.1(Calcium) |
- |
9500 |
|
- |
| Clause 7.1(Chromium + Nickel + Niobium, Vanadium + Titanium + Molybdenum + Boron + Calcium) |
- |
9500 |
|
- |
|
31 Dec, 2026 |
- Included w.e.f.11.04.2025 |
| 4528 |
Hi Physix Laboratory India Private Limited, Pune
| 7126926
| IS 302 : Part 1 (2024) |
Household and Similar Electrical Appliances â Safety Part 1 General Requirements (Seventh Revision) |
- |
73000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4(General requirement) |
- |
0 |
|
- |
| 5(General conditions for the tests) |
- |
0 |
|
- |
| 6(Classification- IS 302-1) |
- |
0 |
|
- |
| 7(Marking and instructions) |
- |
2000 |
|
- |
| 8.1.1(Protection against live parts in all positions) |
- |
2000 |
|
- |
| 8.1.2(Protection against live parts in openings) |
- |
0 |
|
Testing charges included in Cl.8.1.1 |
| 8.1.3(Protection against live parts in visible glowing heating elements) |
- |
0 |
|
Testing charges included in Cl.8.1.1 |
| 8.1.4(Protection against live parts against protective impedance) |
- |
0 |
|
Testing charges included in Cl.8.1.1 |
| 8.1.5(Live parts of built-in appliances) |
- |
0 |
|
Testing charges included in Cl.8.1.1 |
| 9(Starting of motor operation test requirements and tests) |
- |
0 |
|
- |
| 10.1(Power input) |
- |
2000 |
|
- |
| 10.2(Current input) |
- |
0 |
|
Testing charges included in Cl.10.1 |
| 11.1(General) |
- |
4000 |
|
- |
| 11.2(General) |
- |
0 |
|
Testing charges included in Cl.11.1 |
| 11.3(Heating) |
- |
0 |
|
Testing charges included in Cl.11.1 |
| 11.4(Heating appliances) |
- |
0 |
|
Testing charges included in Cl.11.1 |
| 11.5(Motor-operated appliances) |
- |
0 |
|
Testing charges included in Cl.11.1 |
| 11.6(Combined appliances) |
- |
0 |
|
Testing charges included in Cl.11.1 |
| 11.7(Duration corresponding) |
- |
0 |
|
Testing charges included in Cl.11.1 |
| 11.8(Temperature rise) |
- |
0 |
|
Testing charges included in Cl.11.1 |
| 12(Charging of metal-ion batteries) |
- |
15000 |
|
if applicable |
| 13(Leakage current and electric strength at operating temperature) |
- |
3000 |
|
- |
| 13.2(Leakage current at operating temperature) |
- |
0 |
|
Testing charges included in Cl.13 |
| 13.3(Electric Strength at operating temperature) |
- |
0 |
|
Testing charges included in Cl.13 |
| 14(Transient Over Voltages) |
- |
2000 |
|
- |
| 15.0(Moisture resistance) |
- |
4000 |
|
- |
| 15.1(Ingress Protection test other than IPX0 (IP test)) |
- |
0 |
|
Testing charges included in Cl.15 |
| 15.2(Spillage Test) |
- |
0 |
|
Testing charges included in Cl.15 |
| 15.3(Humidity Test) |
- |
0 |
|
Testing charges included in Cl.15 |
| 16.0(General) |
- |
0 |
|
Testing charges included in Cl.16 |
| 16(Leakage current and electric strength) |
- |
3000 |
|
- |
| 16.2(Leakage Current (after Clause 15)) |
- |
0 |
|
Testing charges included in Cl.16 |
| 16.3(Electric Strength (after clause 15 and 16.2)) |
- |
0 |
|
Testing charges included in Cl.16 |
| 17(Over Load Protection of Transformers and associated circuits) |
- |
4000 |
|
- |
| 17(Overload protection of transformers and associated circuits) |
- |
0 |
|
Testing charges included in Cl.17 |
| 18(Endurance) |
- |
0 |
|
- |
| 19(Abnormal Operation) |
- |
5000 |
|
Charges applicable excluding the test of Cl.19.11.4.1 to Cl.19.11.4.7. The testing charges for EMI/EMC testing (Cl.19.11.4.1 to Cl.19.11.4.7) will be applicable |
| 19.17(Abnormal Operation, IS 302-1) |
- |
0 |
|
Testing charges included in Cl.19 |
| 19.11.4.1(Electrostatic discharges) |
- |
5000 |
|
Complete testing Charges applicable excluding the test of Cl.19.11.4.1 to Cl.19.11.4.7. If applicable, The testing charges for EMI/EMC Testing (Cl.19.11.4.1 to Cl.19.11.4.7) will be charged extra |
| 19.11.4.2(Radiated fields) |
- |
20000 |
|
Complete testing Charges applicable excluding the test of Cl.19.11.4.1 to Cl.19.11.4.7. If applicable, The testing charges for EMI/EMC Testing (Cl.19.11.4.1 to Cl.19.11.4.7) will be charged extra |
| 19.11.4.3(Fast transient bursts) |
- |
5000 |
|
Complete testing Charges applicable excluding the test of Cl.19.11.4.1 to Cl.19.11.4.7. If applicable, The testing charges for EMI/EMC Testing (Cl.19.11.4.1 to Cl.19.11.4.7) will be charged extra |
| 19.11.4.4(Surge immunity test) |
- |
5000 |
|
Complete testing Charges applicable excluding the test of Cl.19.11.4.1 to Cl.19.11.4.7. If applicable, The testing charges for EMI/EMC Testing (Cl.19.11.4.1 to Cl.19.11.4.7) will be charged extra |
| 19.11.4.5(Immunity to conducted discharges) |
- |
10000 |
|
Complete testing Charges applicable excluding the test of Cl.19.11.4.1 to Cl.19.11.4.7. If applicable, The testing charges for EMI/EMC Testing (Cl.19.11.4.1 to Cl.19.11.4.7) will be charged extra |
| 19.11.4.6(Class 3 Voltage dips and interruptions) |
- |
5000 |
|
Complete testing Charges applicable excluding the test of Cl.19.11.4.1 to Cl.19.11.4.7. If applicable, The testing charges for EMI/EMC Testing (Cl.19.11.4.1 to Cl.19.11.4.7) will be charged extra |
| 19.11.4.7(Harmonics) |
- |
5000 |
|
Complete testing Charges applicable excluding the test of Cl.19.11.4.1 to Cl.19.11.4.7. If applicable, The testing charges for EMI/EMC Testing (Cl.19.11.4.1 to Cl.19.11.4.7) will be charged extra |
| 20.1(Stability & Mechanical Hazards, IS 302-1) |
- |
2000 |
|
- |
| 20.2(Stability & Mechanical Hazards, IS 302-1) |
- |
0 |
|
Testing charges included in Cl.20 |
| 21.1(Mechanical Strength, IS 302-1) |
- |
3000 |
|
- |
| 21.2(Mechanical Strength, IS 302-1) |
- |
0 |
|
Testing charges included in Cl.21 |
| 21.3(Mechanical Strength, IS 302-1) |
- |
0 |
|
Testing charges included in Cl.21 |
| 22.1(Construction, IS 302-1) |
- |
5000 |
|
- |
| 22.5(Construction) |
- |
0 |
|
Testing charges included in Cl.22 |
| 22.6(Construction, IS 302-1) |
- |
0 |
|
Testing charges included in Cl.22 |
| 22.11(Construction, IS 302-1) |
- |
0 |
|
Testing charges included in Cl.22 |
| 22.16(Construction) |
- |
0 |
|
Testing charges included in Cl.22 |
| 22.32(Construction, IS 302-1) |
- |
0 |
|
Testing charges included in Cl.22 |
| 22.42(Construction) |
- |
0 |
|
Testing charges included in Cl.22 |
| 23.1(Internal Wiring, IS 302-1) |
- |
2000 |
|
- |
| 23.3(Internal Wiring, IS 302-1) |
- |
0 |
|
Testing charges included in Cl.23 |
| 24(Components) |
- |
3000 |
|
- |
| 25.8(Supply Connection and External Flexible Cords, IS 302-1) |
- |
1000 |
|
- |
| 25.6(Supply connection and external flexible cords, IS 302-1) |
- |
0 |
|
Testing charges included in Cl.25 |
| 25.7(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
Testing charges included in Cl.25 |
| 25.14(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
Testing charges included in Cl.25 |
| 25.15(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
Testing charges included in Cl.25 |
| 26(Terminals for external conductors) |
- |
1000 |
|
- |
| 26.5(Terminals for external conductors) |
- |
0 |
|
Testing charges included in Cl.26 |
| 27.1(Provision for Earthing, IS 302-1) |
- |
2000 |
|
- |
| 27.5(Provision for Earthing, IS 302-1) |
- |
0 |
|
Testing charges included in Cl.27 |
| 28(Screw test and connections) |
- |
1000 |
|
- |
| 28.1(Screws and connections) |
- |
0 |
|
Testing charges included in Cl.28 |
| 29(clearance, creepage distances and solid insulation) |
- |
2000 |
|
- |
| 30.1(Ball pressure test) |
- |
1000 |
|
- |
| 30.2(Glow Wire Test) |
- |
1000 |
|
- |
| 30.2(Needle Flame Test) |
- |
1000 |
|
- |
| 31(Resistance to Rusting) |
- |
1000 |
|
- |
| 32.1(Radiation Toxicity and Similar Hazards) |
- |
1000 |
|
- |
| A.2(Earth continuity test) |
- |
0 |
|
Testing charges included in Cl.27 |
| 22.2(Construction, IS 302-1) |
- |
0 |
|
Testing charges included in Cl.22 |
| 22.3(Construction, IS 302-1) |
- |
0 |
|
Testing charges included in Cl.22 |
| B.22.4(Construction, IS 302-1) |
- |
0 |
|
Testing charges included in Cl.22 |
| B.22.5(Construction, IS 302-1) |
- |
0 |
|
Testing charges included in Cl.22 |
| Annex C(Ageing test on motors) |
- |
0 |
|
- |
| Annex D(Thermal motor protectors) |
- |
0 |
|
- |
| 18(Endurance) |
- |
0 |
|
- |
| 16.1(General) |
- |
0 |
|
Testing charges included in Cl.16 |
| 15.2(Moisture resistance) |
- |
0 |
|
Testing charges included in Cl.15 |
| 4(General requirement) |
- |
0 |
|
- |
| 5(General conditions for the tests) |
- |
0 |
|
- |
| 6(Classification- IS 302-1) |
- |
0 |
|
- |
| 7(Marking and instructions) |
- |
0 |
|
- |
| 8.1.1(Protection against live parts in all positions) |
- |
0 |
|
- |
| 8.1.2(Protection against live parts in openings) |
- |
0 |
|
- |
| 8.1.3(Protection against live parts in visible glowing heating elements) |
- |
0 |
|
- |
| 8.1.4(Protection against live parts against protective impedance) |
- |
0 |
|
- |
| 8.1.5(Live parts of built-in appliances) |
- |
0 |
|
- |
| 9(Starting of motor operation test requirements and tests) |
- |
0 |
|
- |
| 10.1(Power input) |
- |
0 |
|
- |
| 10.2(Current input) |
- |
0 |
|
- |
| 11.1(General) |
- |
0 |
|
- |
| 11.2(General) |
- |
0 |
|
- |
| 11.3(Heating) |
- |
0 |
|
- |
| 11.4(Heating appliances) |
- |
0 |
|
- |
| 11.5(Motor-operated appliances) |
- |
0 |
|
- |
| 11.6(Combined appliances) |
- |
0 |
|
- |
| 11.7(Duration corresponding) |
- |
0 |
|
- |
| 11.8(Temperature rise) |
- |
0 |
|
- |
| 12(Charging of metal-ion batteries) |
- |
0 |
|
- |
| 13(Leakage current and electric strength at operating temperature) |
- |
0 |
|
- |
| 13.2(Leakage current at operating temperature) |
- |
0 |
|
- |
| 13.3(Electric Strength at operating temperature) |
- |
0 |
|
- |
| 14(Transient Over Voltages) |
- |
0 |
|
- |
| 15.0(Moisture resistance) |
- |
0 |
|
- |
| 15.1(Ingress Protection test other than IPX0 (IP test)) |
- |
0 |
|
- |
| 15.2(Spillage Test) |
- |
0 |
|
- |
| 15.3(Humidity Test) |
- |
0 |
|
- |
| 16.0(General) |
- |
0 |
|
- |
| 16(Leakage current and electric strength) |
- |
0 |
|
- |
| 16.2(Leakage Current (after Clause 15)) |
- |
0 |
|
- |
| 16.3(Electric Strength (after clause 15 and 16.2)) |
- |
0 |
|
- |
| 17(Over Load Protection of Transformers and associated circuits) |
- |
0 |
|
- |
| 17(Overload protection of transformers and associated circuits) |
- |
0 |
|
- |
| 18(Endurance) |
- |
0 |
|
- |
| 19(Abnormal Operation) |
- |
0 |
|
- |
| 19.17(Abnormal Operation, IS 302-1) |
- |
0 |
|
- |
| 19.11.4.1(Electrostatic discharges) |
- |
0 |
|
- |
| 19.11.4.2(Radiated fields) |
- |
0 |
|
- |
| 19.11.4.3(Fast transient bursts) |
- |
0 |
|
- |
| 19.11.4.4(Surge immunity test) |
- |
0 |
|
- |
| 19.11.4.5(Immunity to conducted discharges) |
- |
0 |
|
- |
| 19.11.4.6(Class 3 Voltage dips and interruptions) |
- |
0 |
|
- |
| 19.11.4.7(Harmonics) |
- |
0 |
|
- |
| 20.1(Stability & Mechanical Hazards, IS 302-1) |
- |
0 |
|
- |
| 20.2(Stability & Mechanical Hazards, IS 302-1) |
- |
0 |
|
- |
| 21.1(Mechanical Strength, IS 302-1) |
- |
0 |
|
- |
| 21.2(Mechanical Strength, IS 302-1) |
- |
0 |
|
- |
| 21.3(Mechanical Strength, IS 302-1) |
- |
0 |
|
- |
| 22.1(Construction, IS 302-1) |
- |
0 |
|
- |
| 22.5(Construction) |
- |
0 |
|
- |
| 22.6(Construction, IS 302-1) |
- |
0 |
|
- |
| 22.11(Construction, IS 302-1) |
- |
0 |
|
- |
| 22.16(Construction) |
- |
0 |
|
- |
| 22.32(Construction, IS 302-1) |
- |
0 |
|
- |
| 22.42(Construction) |
- |
0 |
|
- |
| 23.1(Internal Wiring, IS 302-1) |
- |
0 |
|
- |
| 23.3(Internal Wiring, IS 302-1) |
- |
0 |
|
- |
| 24(Components) |
- |
0 |
|
- |
| 25.8(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
- |
| 25.6(Supply connection and external flexible cords, IS 302-1) |
- |
0 |
|
- |
| 25.7(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
- |
| 25.14(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
- |
| 25.15(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
- |
| 26(Terminals for external conductors) |
- |
0 |
|
- |
| 26.5(Terminals for external conductors) |
- |
0 |
|
- |
| 27.1(Provision for Earthing, IS 302-1) |
- |
0 |
|
- |
| 27.5(Provision for Earthing, IS 302-1) |
- |
0 |
|
- |
| 28(Screw test and connections) |
- |
0 |
|
- |
| 28.1(Screws and connections) |
- |
0 |
|
- |
| 29(clearance, creepage distances and solid insulation) |
- |
0 |
|
- |
| 30.1(Ball pressure test) |
- |
0 |
|
- |
| 30.2(Glow Wire Test) |
- |
0 |
|
- |
| 30.2(Needle Flame Test) |
- |
0 |
|
- |
| 31(Resistance to Rusting) |
- |
0 |
|
- |
| 32.1(Radiation Toxicity and Similar Hazards) |
- |
0 |
|
- |
| A.2(Earth continuity test) |
- |
0 |
|
- |
| 22.2(Construction, IS 302-1) |
- |
0 |
|
- |
| 22.3(Construction, IS 302-1) |
- |
0 |
|
- |
| B.22.4(Construction, IS 302-1) |
- |
0 |
|
- |
| B.22.5(Construction, IS 302-1) |
- |
0 |
|
- |
| Annex C(Ageing test on motors) |
- |
0 |
|
- |
| Annex D(Thermal motor protectors) |
- |
0 |
|
- |
| 18(Endurance) |
- |
0 |
|
- |
| 16.1(General) |
- |
0 |
|
- |
| 15.2(Moisture resistance) |
- |
0 |
|
- |
| 4(General requirement) |
- |
0 |
|
- |
| 5(General conditions for the tests) |
- |
0 |
|
- |
| 6(Classification- IS 302-1) |
- |
0 |
|
- |
| 7(Marking and instructions) |
- |
0 |
|
- |
| 8.1.1(Protection against live parts in all positions) |
- |
0 |
|
- |
| 8.1.2(Protection against live parts in openings) |
- |
0 |
|
- |
| 8.1.3(Protection against live parts in visible glowing heating elements) |
- |
0 |
|
- |
| 8.1.4(Protection against live parts against protective impedance) |
- |
0 |
|
- |
| 8.1.5(Live parts of built-in appliances) |
- |
0 |
|
- |
| 9(Starting of motor operation test requirements and tests) |
- |
0 |
|
- |
| 10.1(Power input) |
- |
0 |
|
- |
| 10.2(Current input) |
- |
0 |
|
- |
| 11.1(General) |
- |
0 |
|
- |
| 11.2(General) |
- |
0 |
|
- |
| 11.3(Heating) |
- |
0 |
|
- |
| 11.4(Heating appliances) |
- |
0 |
|
- |
| 11.5(Motor-operated appliances) |
- |
0 |
|
- |
| 11.6(Combined appliances) |
- |
0 |
|
- |
| 11.7(Duration corresponding) |
- |
0 |
|
- |
| 11.8(Temperature rise) |
- |
0 |
|
- |
| 12(Charging of metal-ion batteries) |
- |
0 |
|
- |
| 13(Leakage current and electric strength at operating temperature) |
- |
0 |
|
- |
| 13.2(Leakage current at operating temperature) |
- |
0 |
|
- |
| 13.3(Electric Strength at operating temperature) |
- |
0 |
|
- |
| 14(Transient Over Voltages) |
- |
0 |
|
- |
| 15.0(Moisture resistance) |
- |
0 |
|
- |
| 15.1(Ingress Protection test other than IPX0 (IP test)) |
- |
0 |
|
- |
| 15.2(Spillage Test) |
- |
0 |
|
- |
| 15.3(Humidity Test) |
- |
0 |
|
- |
| 16.0(General) |
- |
0 |
|
- |
| 16(Leakage current and electric strength) |
- |
0 |
|
- |
| 16.2(Leakage Current (after Clause 15)) |
- |
0 |
|
- |
| 16.3(Electric Strength (after clause 15 and 16.2)) |
- |
0 |
|
- |
| 17(Over Load Protection of Transformers and associated circuits) |
- |
0 |
|
- |
| 17(Overload protection of transformers and associated circuits) |
- |
0 |
|
- |
| 18(Endurance) |
- |
0 |
|
- |
| 19(Abnormal Operation) |
- |
0 |
|
- |
| 19.17(Abnormal Operation, IS 302-1) |
- |
0 |
|
- |
| 19.11.4.1(Electrostatic discharges) |
- |
0 |
|
- |
| 19.11.4.2(Radiated fields) |
- |
0 |
|
- |
| 19.11.4.3(Fast transient bursts) |
- |
0 |
|
- |
| 19.11.4.4(Surge immunity test) |
- |
0 |
|
- |
| 19.11.4.5(Immunity to conducted discharges) |
- |
0 |
|
- |
| 19.11.4.6(Class 3 Voltage dips and interruptions) |
- |
0 |
|
- |
| 19.11.4.7(Harmonics) |
- |
0 |
|
- |
| 20.1(Stability & Mechanical Hazards, IS 302-1) |
- |
0 |
|
- |
| 20.2(Stability & Mechanical Hazards, IS 302-1) |
- |
0 |
|
- |
| 21.1(Mechanical Strength, IS 302-1) |
- |
0 |
|
- |
| 21.2(Mechanical Strength, IS 302-1) |
- |
0 |
|
- |
| 21.3(Mechanical Strength, IS 302-1) |
- |
0 |
|
- |
| 22.1(Construction, IS 302-1) |
- |
0 |
|
- |
| 22.5(Construction) |
- |
0 |
|
- |
| 22.6(Construction, IS 302-1) |
- |
0 |
|
- |
| 22.11(Construction, IS 302-1) |
- |
0 |
|
- |
| 22.16(Construction) |
- |
0 |
|
- |
| 22.32(Construction, IS 302-1) |
- |
0 |
|
- |
| 22.42(Construction) |
- |
0 |
|
- |
| 23.1(Internal Wiring, IS 302-1) |
- |
0 |
|
- |
| 23.3(Internal Wiring, IS 302-1) |
- |
0 |
|
- |
| 24(Components) |
- |
0 |
|
- |
| 25.8(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
- |
| 25.6(Supply connection and external flexible cords, IS 302-1) |
- |
0 |
|
- |
| 25.7(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
- |
| 25.14(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
- |
| 25.15(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
- |
| 26(Terminals for external conductors) |
- |
0 |
|
- |
| 26.5(Terminals for external conductors) |
- |
0 |
|
- |
| 27.1(Provision for Earthing, IS 302-1) |
- |
0 |
|
- |
| 27.5(Provision for Earthing, IS 302-1) |
- |
0 |
|
- |
| 28(Screw test and connections) |
- |
0 |
|
- |
| 28.1(Screws and connections) |
- |
0 |
|
- |
| 29(clearance, creepage distances and solid insulation) |
- |
0 |
|
- |
| 30.1(Ball pressure test) |
- |
0 |
|
- |
| 30.2(Glow Wire Test) |
- |
0 |
|
- |
| 30.2(Needle Flame Test) |
- |
0 |
|
- |
| 31(Resistance to Rusting) |
- |
0 |
|
- |
| 32.1(Radiation Toxicity and Similar Hazards) |
- |
0 |
|
- |
| A.2(Earth continuity test) |
- |
0 |
|
- |
| 22.2(Construction, IS 302-1) |
- |
0 |
|
- |
| 22.3(Construction, IS 302-1) |
- |
0 |
|
- |
| B.22.4(Construction, IS 302-1) |
- |
0 |
|
- |
| B.22.5(Construction, IS 302-1) |
- |
0 |
|
- |
| Annex C(Ageing test on motors) |
- |
0 |
|
- |
| Annex D(Thermal motor protectors) |
- |
0 |
|
- |
| 18(Endurance) |
- |
0 |
|
- |
| 16.1(General) |
- |
0 |
|
- |
| 15.2(Moisture resistance) |
- |
0 |
|
- |
|
20 Jun, 2028 |
- iNCLUDED W.E.F.04.03.2025
EXCLUSION
Cl 32 (Radiation Toxicity and Similar Hazards)
Cl 22.32 (Construction)
CL 24 (Components)
"Domestic Electric Clothes Washing Machines
(For testing charges please refer part 2 standard in LIMS)" |
| 4529 |
BIS, Central Laboratory (CL)
| None
| IS 13098 (2024) |
AUTOMOTIVE VEHICLES TUBES FOR PNEUMATIC TYRES â SPECIFICATION (second revision) |
- |
- View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl 3.3.1 (Thickness Uniformity) |
- |
|
|
|
| Cl 4.1.1 (Elongation) |
- |
|
|
|
| Cl 4.1.2 (Strength of Splice) |
- |
|
|
|
| Cl 5 (AIR TIGHTNESS) |
- |
|
|
|
| Cl 3.2 (Classification) |
- |
|
|
|
| Cl 3.1 (Materials) |
- |
|
|
|
| Cl 6 (MARKING) |
- |
|
|
|
|
- |
- - |
| 4530 |
SIIR, Delhi Shriram Institute For Industrial Research
| 8102006
| IS 4766 (2024) |
Thiram water dispersible powder for slurry seed treatment - Specification (second revision) |
- |
10000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| CL 3.2.1(Description) |
- |
1000 |
|
30% discount |
| CL. 3.2.2(Colour) |
- |
0 |
|
This is portal issue compulsory to map all parameter . We can't do anything from our side for this issue |
| CL 3.2.1(Description) |
- |
0 |
|
(Repeat Entry on portal) This is portal issue compulsory to map all parameter . We can't do anything from our side for this issue |
| CL. 3.2.2(Colour) |
- |
0 |
|
(Repeat Entry on portal) This is portal issue compulsory to map all parameter . We can't do anything from our side for this issue |
| CL 3.3.1(Thiram Content) |
- |
5000 |
|
30% discount |
| CL. 3.2.3(Sieving) |
- |
2000 |
|
30% discount |
| 3.1(Description - IS 4766:2024) |
- |
0 |
|
(Repeat Entry on portal) This is portal issue compulsory to map all parameter . We can't do anything from our side for this issue |
| 3.3, 7.1, Table 1 (i)(Thiram Content - IS 4320:2024) |
- |
0 |
|
(Repeat Entry on portal) This is portal issue compulsory to map all parameter . We can't do anything from our side for this issue |
| 3.3, 7.1, Table 1 (ii)(Material passing through 53 micron IS sieve - IS 6940:1982) |
- |
0 |
|
(Repeat Entry on portal) This is portal issue compulsory to map all parameter . We can't do anything from our side for this issue |
| 3.3, 7.1, Table 1 (iii)(Wettability - IS 6940:1982) |
- |
2000 |
|
30% discount |
| CL 3.1(Description) |
- |
0 |
|
(Repeat Entry on portal) This is portal issue compulsory to map all parameter . We can't do anything from our side for this issue |
| CL 3.3, Table 1, S.No (i)(Thiram Content) |
- |
0 |
|
(Repeat Entry on portal) This is portal issue compulsory to map all parameter . We can't do anything from our side for this issue |
| CL 3.3, Table 1, S.No (ii)(Sieving) |
- |
0 |
|
(Repeat Entry on portal) This is portal issue compulsory to map all parameter . We can't do anything from our side for this issue |
| CL 3.3, Table 1, S.No (iii)(Wettability) |
- |
0 |
|
(Repeat Entry on portal) This is portal issue compulsory to map all parameter . We can't do anything from our side for this issue |
| CL 3.1(Description) |
- |
0 |
|
(Repeat Entry on portal) This is portal issue compulsory to map all parameter . We can't do anything from our side for this issue |
| CL 3.1(Description) |
- |
0 |
|
(Repeat Entry on portal) This is portal issue compulsory to map all parameter . We can't do anything from our side for this issue |
| Table 1, S.No (i)(Bis (dimethylthiocarbamoyl) disulphide content, percent by mass, Min) |
- |
0 |
|
These parameter is not covered in BIS Specification IS 4766:2024. Therefor , we have not included the charges for Active Ingredient , LOD , Ash content in this as per IS 4766:2024. We are also not claiming these tests under 2024 version of IS 4766 |
| Table 1, S.No (ii)(Loss on drying at 60 °C, percent by mass, Max) |
- |
0 |
|
These parameter is not covered in BIS Specification IS 4766:2024. Therefor , we have not included the charges for Active Ingredient , LOD , Ash content in this as per IS 4766:2024. We are also not claiming these tests under 2024 version of IS 4766 |
| Table 1, S.No (iii)(Ash content, percent by mass, Max) |
- |
0 |
|
These parameter is not covered in BIS Specification IS 4766:2024. Therefor , we have not included the charges for Active Ingredient , LOD , Ash content in this as per IS 4766:2024. We are also not claiming these tests under 2024 version of IS 4766 |
| CL. 3.2.2(Colour) |
- |
0 |
|
(Repeat Entry on portal) This is portal issue compulsory to map all parameter . We can't do anything from our side for this issue |
| CL 3.2.1(Description) |
- |
0 |
|
(Repeat Entry on portal) This is portal issue compulsory to map all parameter . We can't do anything from our side for this issue |
| CL. 3.2.2(Colour) |
- |
0 |
|
(Repeat Entry on portal) This is portal issue compulsory to map all parameter . We can't do anything from our side for this issue |
| CL 3.3.1(Thiram Content) |
- |
0 |
|
(Repeat Entry on portal) This is portal issue compulsory to map all parameter . We can't do anything from our side for this issue |
| CL. 3.2.3(Sieving) |
- |
0 |
|
(Repeat Entry on portal) This is portal issue compulsory to map all parameter . We can't do anything from our side for this issue |
| 3.1(Description - IS 4766:2024) |
- |
0 |
|
(Repeat Entry on portal) This is portal issue compulsory to map all parameter . We can't do anything from our side for this issue |
| 3.3, 7.1, Table 1 (i)(Thiram Content - IS 4320:2024) |
- |
0 |
|
(Repeat Entry on portal) This is portal issue compulsory to map all parameter . We can't do anything from our side for this issue |
| 3.3, 7.1, Table 1 (ii)(Material passing through 53 micron IS sieve - IS 6940:1982) |
- |
0 |
|
(Repeat Entry on portal) This is portal issue compulsory to map all parameter . We can't do anything from our side for this issue |
| 3.3, 7.1, Table 1 (iii)(Wettability - IS 6940:1982) |
- |
0 |
|
(Repeat Entry on portal) This is portal issue compulsory to map all parameter . We can't do anything from our side for this issue |
| CL 3.1(Description) |
- |
0 |
|
(Repeat Entry on portal) This is portal issue compulsory to map all parameter . We can't do anything from our side for this issue |
| CL 3.3, Table 1, S.No (i)(Thiram Content) |
- |
0 |
|
(Repeat Entry on portal) This is portal issue compulsory to map all parameter . We can't do anything from our side for this issue |
| CL 3.3, Table 1, S.No (ii)(Sieving) |
- |
0 |
|
(Repeat Entry on portal) This is portal issue compulsory to map all parameter . We can't do anything from our side for this issue |
| CL 3.3, Table 1, S.No (iii)(Wettability) |
- |
0 |
|
(Repeat Entry on portal) This is portal issue compulsory to map all parameter . We can't do anything from our side for this issue |
| CL 3.1(Description) |
- |
0 |
|
(Repeat Entry on portal) This is portal issue compulsory to map all parameter . We can't do anything from our side for this issue |
| CL 3.1(Description) |
- |
0 |
|
(Repeat Entry on portal) This is portal issue compulsory to map all parameter . We can't do anything from our side for this issue |
| Table 1, S.No (i)(Bis (dimethylthiocarbamoyl) disulphide content, percent by mass, Min) |
- |
0 |
|
(Repeat Entry on portal) This is portal issue compulsory to map all parameter . We can't do anything from our side for this issue |
| Table 1, S.No (ii)(Loss on drying at 60 °C, percent by mass, Max) |
- |
0 |
|
(Repeat Entry on portal) This is portal issue compulsory to map all parameter . We can't do anything from our side for this issue |
| Table 1, S.No (iii)(Ash content, percent by mass, Max) |
- |
0 |
|
(Repeat Entry on portal) This is portal issue compulsory to map all parameter . We can't do anything from our side for this issue |
| CL 3.2.1(Description) |
- |
0 |
|
(Repeat Entry on portal) This is portal issue compulsory to map all parameter . We can't do anything from our side for this issue |
| CL. 3.2.2(Colour) |
- |
0 |
|
(Repeat Entry on portal) This is portal issue compulsory to map all parameter . We can't do anything from our side for this issue |
| CL 3.2.1(Description) |
- |
0 |
|
(Repeat Entry on portal) This is portal issue compulsory to map all parameter . We can't do anything from our side for this issue |
| CL. 3.2.2(Colour) |
- |
0 |
|
(Repeat Entry on portal) This is portal issue compulsory to map all parameter . We can't do anything from our side for this issue |
| CL 3.3.1(Thiram Content) |
- |
0 |
|
(Repeat Entry on portal) This is portal issue compulsory to map all parameter . We can't do anything from our side for this issue |
| CL. 3.2.3(Sieving) |
- |
0 |
|
(Repeat Entry on portal) This is portal issue compulsory to map all parameter . We can't do anything from our side for this issue |
| 3.1(Description - IS 4766:2024) |
- |
0 |
|
(Repeat Entry on portal) This is portal issue compulsory to map all parameter . We can't do anything from our side for this issue |
| 3.3, 7.1, Table 1 (i)(Thiram Content - IS 4320:2024) |
- |
0 |
|
(Repeat Entry on portal) This is portal issue compulsory to map all parameter . We can't do anything from our side for this issue |
| 3.3, 7.1, Table 1 (ii)(Material passing through 53 micron IS sieve - IS 6940:1982) |
- |
0 |
|
(Repeat Entry on portal) This is portal issue compulsory to map all parameter . We can't do anything from our side for this issue |
| 3.3, 7.1, Table 1 (iii)(Wettability - IS 6940:1982) |
- |
0 |
|
(Repeat Entry on portal) This is portal issue compulsory to map all parameter . We can't do anything from our side for this issue |
| CL 3.1(Description) |
- |
0 |
|
(Repeat Entry on portal) This is portal issue compulsory to map all parameter . We can't do anything from our side for this issue |
| CL 3.3, Table 1, S.No (i)(Thiram Content) |
- |
0 |
|
(Repeat Entry on portal) This is portal issue compulsory to map all parameter . We can't do anything from our side for this issue |
| CL 3.3, Table 1, S.No (ii)(Sieving) |
- |
0 |
|
(Repeat Entry on portal) This is portal issue compulsory to map all parameter . We can't do anything from our side for this issue |
| CL 3.3, Table 1, S.No (iii)(Wettability) |
- |
0 |
|
(Repeat Entry on portal) This is portal issue compulsory to map all parameter . We can't do anything from our side for this issue |
| CL 3.1(Description) |
- |
0 |
|
(Repeat Entry on portal) This is portal issue compulsory to map all parameter . We can't do anything from our side for this issue |
| CL 3.1(Description) |
- |
0 |
|
(Repeat Entry on portal) This is portal issue compulsory to map all parameter . We can't do anything from our side for this issue |
| Table 1, S.No (i)(Bis (dimethylthiocarbamoyl) disulphide content, percent by mass, Min) |
- |
0 |
|
(Repeat Entry on portal) This is portal issue compulsory to map all parameter . We can't do anything from our side for this issue |
| Table 1, S.No (ii)(Loss on drying at 60 °C, percent by mass, Max) |
- |
0 |
|
(Repeat Entry on portal) This is portal issue compulsory to map all parameter . We can't do anything from our side for this issue |
| Table 1, S.No (iii)(Ash content, percent by mass, Max) |
- |
0 |
|
(Repeat Entry on portal) This is portal issue compulsory to map all parameter . We can't do anything from our side for this issue |
| CL 3.2.1(Description) |
- |
0 |
|
(Repeat Entry on portal) This is portal issue compulsory to map all parameter . We can't do anything from our side for this issue |
| CL 3.2.1(Description) |
- |
0 |
|
(Repeat Entry on portal) This is portal issue compulsory to map all parameter . We can't do anything from our side for this issue |
| CL. 3.2.2(Colour) |
- |
0 |
|
(Repeat Entry on portal) This is portal issue compulsory to map all parameter . We can't do anything from our side for this issue |
| CL 3.3.1(Thiram Content) |
- |
0 |
|
(Repeat Entry on portal) This is portal issue compulsory to map all parameter . We can't do anything from our side for this issue |
| CL. 3.2.3(Sieving) |
- |
0 |
|
(Repeat Entry on portal) This is portal issue compulsory to map all parameter . We can't do anything from our side for this issue |
| 3.1(Description - IS 4766:2024) |
- |
0 |
|
(Repeat Entry on portal) This is portal issue compulsory to map all parameter . We can't do anything from our side for this issue |
| 3.3, 7.1, Table 1 (i)(Thiram Content - IS 4320:2024) |
- |
0 |
|
(Repeat Entry on portal) This is portal issue compulsory to map all parameter . We can't do anything from our side for this issue |
| 3.3, 7.1, Table 1 (ii)(Material passing through 53 micron IS sieve - IS 6940:1982) |
- |
0 |
|
(Repeat Entry on portal) This is portal issue compulsory to map all parameter . We can't do anything from our side for this issue |
| 3.3, 7.1, Table 1 (iii)(Wettability - IS 6940:1982) |
- |
0 |
|
(Repeat Entry on portal) This is portal issue compulsory to map all parameter . We can't do anything from our side for this issue |
| CL 3.1(Description) |
- |
0 |
|
(Repeat Entry on portal) This is portal issue compulsory to map all parameter . We can't do anything from our side for this issue |
| CL 3.3, Table 1, S.No (i)(Thiram Content) |
- |
0 |
|
(Repeat Entry on portal) This is portal issue compulsory to map all parameter . We can't do anything from our side for this issue |
| CL 3.3, Table 1, S.No (ii)(Sieving) |
- |
0 |
|
(Repeat Entry on portal) This is portal issue compulsory to map all parameter . We can't do anything from our side for this issue |
| CL 3.3, Table 1, S.No (iii)(Wettability) |
- |
0 |
|
(Repeat Entry on portal) This is portal issue compulsory to map all parameter . We can't do anything from our side for this issue |
| CL 3.1(Description) |
- |
0 |
|
(Repeat Entry on portal) This is portal issue compulsory to map all parameter . We can't do anything from our side for this issue |
| CL 3.1(Description) |
- |
0 |
|
(Repeat Entry on portal) This is portal issue compulsory to map all parameter . We can't do anything from our side for this issue |
| Table 1, S.No (i)(Bis (dimethylthiocarbamoyl) disulphide content, percent by mass, Min) |
- |
0 |
|
These parameter is not covered in BIS Specification IS 4766:2024. Therefor , we have not included the charges for Active Ingredient , LOD , Ash content in this as per IS 4766:2024. We are also not claiming these tests under 2024 version of IS 4766 |
| Table 1, S.No (ii)(Loss on drying at 60 °C, percent by mass, Max) |
- |
0 |
|
These parameter is not covered in BIS Specification IS 4766:2024. Therefor , we have not included the charges for Active Ingredient , LOD , Ash content in this as per IS 4766:2024. We are also not claiming these tests under 2024 version of IS 4766 |
| Table 1, S.No (iii)(Ash content, percent by mass, Max) |
- |
0 |
|
These parameter is not covered in BIS Specification IS 4766:2024. Therefor , we have not included the charges for Active Ingredient , LOD , Ash content in this as per IS 4766:2024. We are also not claiming these tests under 2024 version of IS 4766 |
| CL 3.2.1(Description) |
- |
0 |
|
(Repeat Entry on portal) This is portal issue compulsory to map all parameter . We can't do anything from our side for this issue |
| CL. 3.2.2(Colour) |
- |
0 |
|
(Repeat Entry on portal) This is portal issue compulsory to map all parameter . We can't do anything from our side for this issue |
| CL 3.2.1(Description) |
- |
0 |
|
(Repeat Entry on portal) This is portal issue compulsory to map all parameter . We can't do anything from our side for this issue |
| CL. 3.2.2(Colour) |
- |
0 |
|
(Repeat Entry on portal) This is portal issue compulsory to map all parameter . We can't do anything from our side for this issue |
| CL 3.3.1(Thiram Content) |
- |
0 |
|
(Repeat Entry on portal) This is portal issue compulsory to map all parameter . We can't do anything from our side for this issue |
| CL. 3.2.3(Sieving) |
- |
0 |
|
(Repeat Entry on portal) This is portal issue compulsory to map all parameter . We can't do anything from our side for this issue |
| 3.1(Description - IS 4766:2024) |
- |
0 |
|
(Repeat Entry on portal) This is portal issue compulsory to map all parameter . We can't do anything from our side for this issue |
| 3.3, 7.1, Table 1 (i)(Thiram Content - IS 4320:2024) |
- |
0 |
|
(Repeat Entry on portal) This is portal issue compulsory to map all parameter . We can't do anything from our side for this issue |
| 3.3, 7.1, Table 1 (ii)(Material passing through 53 micron IS sieve - IS 6940:1982) |
- |
0 |
|
(Repeat Entry on portal) This is portal issue compulsory to map all parameter . We can't do anything from our side for this issue |
| 3.3, 7.1, Table 1 (iii)(Wettability - IS 6940:1982) |
- |
0 |
|
(Repeat Entry on portal) This is portal issue compulsory to map all parameter . We can't do anything from our side for this issue |
| CL 3.1(Description) |
- |
0 |
|
(Repeat Entry on portal) This is portal issue compulsory to map all parameter . We can't do anything from our side for this issue |
| CL 3.3, Table 1, S.No (i)(Thiram Content) |
- |
0 |
|
(Repeat Entry on portal) This is portal issue compulsory to map all parameter . We can't do anything from our side for this issue |
| CL 3.3, Table 1, S.No (ii)(Sieving) |
- |
0 |
|
(Repeat Entry on portal) This is portal issue compulsory to map all parameter . We can't do anything from our side for this issue |
| CL 3.3, Table 1, S.No (iii)(Wettability) |
- |
0 |
|
(Repeat Entry on portal) This is portal issue compulsory to map all parameter . We can't do anything from our side for this issue |
| CL 3.1(Description) |
- |
0 |
|
(Repeat Entry on portal) This is portal issue compulsory to map all parameter . We can't do anything from our side for this issue |
| CL 3.1(Description) |
- |
0 |
|
(Repeat Entry on portal) This is portal issue compulsory to map all parameter . We can't do anything from our side for this issue |
| Table 1, S.No (i)(Bis (dimethylthiocarbamoyl) disulphide content, percent by mass, Min) |
- |
0 |
|
These parameter is not covered in BIS Specification IS 4766:2024. Therefor , we have not included the charges for Active Ingredient , LOD , Ash content in this as per IS 4766:2024. We are also not claiming these tests under 2024 version of IS 4766 |
| Table 1, S.No (ii)(Loss on drying at 60 °C, percent by mass, Max) |
- |
0 |
|
These parameter is not covered in BIS Specification IS 4766:2024. Therefor , we have not included the charges for Active Ingredient , LOD , Ash content in this as per IS 4766:2024. We are also not claiming these tests under 2024 version of IS 4766 |
| Table 1, S.No (iii)(Ash content, percent by mass, Max) |
- |
0 |
|
These parameter is not covered in BIS Specification IS 4766:2024. Therefor , we have not included the charges for Active Ingredient , LOD , Ash content in this as per IS 4766:2024. We are also not claiming these tests under 2024 version of IS 4766 |
| CL 3.2.1(Description) |
- |
0 |
|
(Repeat Entry on portal) This is portal issue compulsory to map all parameter . We can't do anything from our side for this issue |
| CL. 3.2.2(Colour) |
- |
0 |
|
(Repeat Entry on portal) This is portal issue compulsory to map all parameter . We can't do anything from our side for this issue |
| 3.1(Description - IS 4766:2024) |
- |
0 |
|
- |
| 3.3, 7.1, Table 1 (i)(Thiram Content - IS 4320:2024) |
- |
0 |
|
- |
| 3.3, 7.1, Table 1 (ii)(Material passing through 53 micron IS sieve - IS 6940:1982) |
- |
0 |
|
- |
| 3.3, 7.1, Table 1 (iii)(Wettability - IS 6940:1982) |
- |
0 |
|
- |
|
31 Dec, 2026 |
- Included w.e.f 26.09.2025
Exclusion: "CL 3.1 (Description)
CL 3.2.1 (Description)
CL 3.3, Table 1, S.No (i) (Thiram Content)
CL 3.3, Table 1, S.No (iii) (Wettability)
CL 3.3.1 (Thiram Content)
CL. 3.2.2 (Colour)
CL. 3.2.3 (Sieving)
Table 1, S.No (i) (Bis (dimethylthiocarbamoyl) disulphide content, percent by mass, Min)
" |