| 4681 |
EMC Testing and Compliance LLP, Gurugram
| 8141526
| IS 302 : Part 2 : Sec 26 (2014) |
Safety of household and similar electrical appliances: Part 2 particular requirements: Sec 26 clocks (First Revision) |
- |
50000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 6.0(Classification) |
- |
1000 |
|
- |
| 7(Marking and instructions) |
- |
1000 |
|
- |
| 8(Protection against live parts) |
- |
2000 |
|
- |
| 9(STARTING OF MOTOR-OPERATED APPLIANCES) |
- |
0 |
|
- |
| 10(POWER INPUT AND CURRENT) |
- |
2000 |
|
- |
| 11(HEATING) |
- |
5000 |
|
- |
| 13(LEAKAGE CURRENT AND ELECTRIC STRENGTH AT OPERATING TEMPERATURE) |
- |
5000 |
|
- |
| 14(TRANSIENT OVERVOLTAGES) |
- |
10000 |
|
- |
| 15(MOISTURE RESISTANCE) |
- |
5000 |
|
- |
| 16(LEAKAGE CURRENT AND ELECTRIC STRENGTH) |
- |
5000 |
|
- |
| 17(OVERLOAD PROTECTION OF TRANSFORMERS AND ASSOCIATED CIRCUITS) |
- |
5000 |
|
- |
| 18(ENDURANCE) |
- |
0 |
|
- |
| 19(ABNORMAL OPERATION) |
- |
5000 |
|
- |
| 20(STABILITY AND MECHANICAL HAZARDS) |
- |
2000 |
|
- |
| 21(MECHANICAL STRENGTH) |
- |
2000 |
|
- |
| 22(CONSTRUCTION) |
- |
2000 |
|
- |
| 23(INTERNAL WIRING) |
- |
2000 |
|
- |
| 24(COMPONENTS) |
- |
2000 |
|
- |
| 25(SUPPLY CONNECTION AND EXTERNAL FLEXIBLE CORDS) |
- |
2000 |
|
- |
| 26(TERMINALS FOR EXTERNAL CONDUCTORS) |
- |
2000 |
|
- |
| 27(PROVISION FOR EARTHING) |
- |
2000 |
|
- |
| 28(SCREWS AND CONNECTIONS) |
- |
2000 |
|
- |
| 29(CLEARANCES, CREEPAGE DISTANCES AND SOLID INSULATION) |
- |
2000 |
|
- |
| 30(RESISTANCE TO HEAT AND FIRE) |
- |
5000 |
|
- |
| 31(RESISTANCE TO RUSTING) |
- |
2000 |
|
- |
| 32(RADIATION, TOXICITY AND SIMILAR HAZARDS) |
- |
2000 |
|
- |
| 22.16(Automatic cord reel) |
- |
1000 |
|
- |
| 22.32(Oxygen bomb for rubber material) |
- |
1000 |
|
- |
| 22.47(Water pressure inlet) |
- |
1000 |
|
- |
| 22.3(Flexing test) |
- |
1000 |
|
- |
| 24(Components) |
- |
2000 |
|
- |
| 5(General conditions for the tests) |
- |
500 |
|
- |
| 4(General Requirements) |
- |
500 |
|
- |
| 22.46(Software) |
- |
2000 |
|
- |
|
19 Jul, 2027 |
- Included w.e.f 26.06.2025 Exclusion: Cl 19.11.4.1-19.11.4.7(EMI/EMC) |
| 4682 |
EMC Testing and Compliance LLP, Gurugram
| 8141526
| IS 302 : Part 2 : Sec 202 (1992) |
Safety of household and similar electrical appliances: Part 2 particular requirements: Sec 202 electric stoves |
- |
50000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 6(Classification- IS 302-1 ) |
- |
500 |
|
- |
| 6(Classification- IS 302-1) |
- |
5000 |
|
- |
| 7.1(Marking- IS 302-1) |
- |
1000 |
|
- |
| 7.1(Marking- IS 302-1) |
- |
1000 |
|
- |
| 7.1(Marking- IS 302-1) |
- |
1000 |
|
- |
| 7.1(Marking- IS 302-1) |
- |
1000 |
|
- |
| 7.1(Marking- IS 302-1) |
- |
1000 |
|
- |
| 7.1(Marking- IS 302-1) |
- |
1000 |
|
- |
| 7.1(Marking- IS 302-1) |
- |
1000 |
|
- |
| 7.1(Marking- IS 302-1) |
- |
1000 |
|
- |
| 7.1(Marking- IS 302-1) |
- |
1000 |
|
- |
| 7.3(Marking- IS 302-1) |
- |
1000 |
|
- |
| 7.4(Marking- IS 302-1) |
- |
1000 |
|
- |
| 7.6(Marking- IS 302-1) |
- |
1000 |
|
- |
| 7.11(Marking- IS 302-1) |
- |
1000 |
|
- |
| 7.12(Marking- IS 302-1) |
- |
1000 |
|
- |
| 7.13(Marking- IS 302-1) |
- |
1000 |
|
- |
| 7.14(Marking- IS 302-1) |
- |
1000 |
|
- |
| 7.15(Marking- IS 302-1) |
- |
1000 |
|
- |
| 7.101(Marking) |
- |
1000 |
|
- |
| 8( Protection Against Electric Shock, IS 302-1) |
- |
2000 |
|
- |
| 10(Power Input and Current, IS 302-1) |
- |
2000 |
|
- |
| 11(Heating, IS 302-1) |
- |
5000 |
|
- |
| 11(Heating, IS 302-1) |
- |
5000 |
|
- |
| 11(Heating, IS 302-1) |
- |
5000 |
|
- |
| 11(Heating, IS 302-1) |
- |
5000 |
|
- |
| 11(Heating, IS 302-1) |
- |
5000 |
|
- |
| 11(Heating, IS 302-1) |
- |
5000 |
|
- |
| 11(Heating, IS 302-1) |
- |
5000 |
|
- |
| 12(Operation under overload conditions of appliances with heating elements, IS 302-2-202: 1992) |
- |
0 |
|
- |
| 13(Electrical Insulation and Leakage Current at Operating Temperature: Leakage current, IS 302-1) |
- |
5000 |
|
- |
| 13(Electrical Insulation and Leakage Current at Operating Temperature: High Voltage, IS 302-1) |
- |
5000 |
|
- |
| 15.1(Moisture Resistance, IS 302-1) |
- |
5000 |
|
- |
| 15.3(Moisture Resistance, IS 302-1) |
- |
5000 |
|
- |
| 16(Electrical Insulation and Leakage Current at Operating Temperature: Leakage current, IS 302-1) |
- |
5000 |
|
- |
| 16(Electrical Insulation and Leakage Current at Operating Temperature: High Voltage, IS 302-1) |
- |
5000 |
|
- |
| 19.2(Abnormal Operation, IS 302-1) |
- |
5000 |
|
- |
| 19.2(Abnormal Operation, IS 302-1) |
- |
5000 |
|
- |
| 19.3(Abnormal Operation, IS 302-1) |
- |
5000 |
|
- |
| 19.3(Abnormal Operation, IS 302-1) |
- |
5000 |
|
- |
| 20.1(Stability & Mechanical Hazards, IS 302-1) |
- |
2000 |
|
- |
| 21.1(Mechanical Strength, IS 302-1 & IS 302-2-202) |
- |
2000 |
|
- |
| 22(Construction, IS 302-1) |
- |
2000 |
|
- |
| 22.101(Construction) |
- |
2000 |
|
- |
| 22.102(Construction) |
- |
2000 |
|
- |
| 22.103(Construction) |
- |
2000 |
|
- |
| 22.104(Construction) |
- |
2000 |
|
- |
| 22.105(Construction) |
- |
2000 |
|
- |
| 22.105.1(Construction) |
- |
2000 |
|
- |
| 22.105.2(Construction) |
- |
2000 |
|
- |
| 22.106(Construction) |
- |
2000 |
|
- |
| 22.107(Construction) |
- |
2000 |
|
- |
| 11.107.1(Construction) |
- |
0 |
|
- |
| 23.1(Internal Wiring, IS 302-1) |
- |
2000 |
|
- |
| 23.2(Internal Wiring, IS 302-1) |
- |
2000 |
|
- |
| 23.8(Internal Wiring, IS 302-1) |
- |
2000 |
|
- |
| 23.9(Internal Wiring, IS 302-1) |
- |
2000 |
|
- |
| 23.10(Internal Wiring, IS 302-1) |
- |
2000 |
|
- |
| 24.1(Components, IS 302-1) |
- |
2000 |
|
- |
| 24.2(Components, IS 302-1) |
- |
2000 |
|
- |
| 24.101(Components) |
- |
2000 |
|
- |
| 25.1(Supply Connection and External Flexible Cords, IS 302-1) |
- |
2000 |
|
- |
| 25.4(Supply Connection and External Flexible Cords) |
- |
2000 |
|
- |
| 25.5(Supply Connection and External Flexible Cords, IS 302-1) |
- |
2000 |
|
- |
| 25.6(Supply Connection and External Flexible Cords, IS 302-1) |
- |
2000 |
|
- |
| 25.8(Supply Connection and External Flexible Cords, IS 302-1) |
- |
2000 |
|
- |
| 26.9(Supply Connection and External Flexible Cords, IS 302-1) |
- |
2000 |
|
- |
| 25.1(Supply Connection and External Flexible Cords, IS 302-1) |
- |
2000 |
|
- |
| 25.11(Supply Connection and External Flexible Cords, IS 302-1) |
- |
2000 |
|
- |
| 25.12(Supply Connection and External Flexible Cords, IS 302-1) |
- |
2000 |
|
- |
| 25.15(Supply Connection and External Flexible Cords, IS 302-1) |
- |
2000 |
|
- |
| 25.16(Supply Connection and External Flexible Cords, IS 302-1) |
- |
2000 |
|
- |
| 25.17(Supply Connection and External Flexible Cords, IS 302-1) |
- |
2000 |
|
- |
| 25.18(Supply Connection and External Flexible Cords, IS 302-1) |
- |
2000 |
|
- |
| 25.19(Supply Connection and External Flexible Cords, IS 302-1) |
- |
2000 |
|
- |
| 25.2(Supply Connection and External Flexible Cords, IS 302-1) |
- |
2000 |
|
- |
| 25.21(Supply Connection and External Flexible Cords, IS 302-1) |
- |
2000 |
|
- |
| 25.22(Supply Connection and External Flexible Cords, IS 302-1) |
- |
2000 |
|
- |
| 26(Terminals for External Conductors, IS 302-1) |
- |
2000 |
|
- |
| 27.1(Provision for Earthing, IS 302-1) |
- |
2000 |
|
- |
| 27.2(Provision for Earthing, IS 302-1) |
- |
2000 |
|
- |
| 27.3(Provision for Earthing, IS 302-1) |
- |
2000 |
|
- |
| 27.4(Provision for Earthing, IS 302-1) |
- |
2000 |
|
- |
| 27.5(Provision for Earthing, IS 302-1) |
- |
2000 |
|
- |
| 28(Screws & Connections, IS 302-1) |
- |
2000 |
|
- |
| 29.1(Clearances, Creepage distances and Solid Insulation, IS 302-1) |
- |
2000 |
|
- |
| 29.2(Clearances, Creepage distances and Solid Insulation, IS 302-1) |
- |
2000 |
|
- |
| 30.1(Resistance to Heat, Fire & Tracking, IS 302-1) |
- |
5000 |
|
- |
| 30.2(Resistance to Heat, Fire & Tracking, IS 302-1) |
- |
5000 |
|
- |
| 31(Resistance of Rusting, IS 302-1) |
- |
1000 |
|
- |
|
19 Jul, 2027 |
- Included w.e.f.24.06.2025
Exclusion
(EMI/EMC) Cl 19.11.4.1 to Cl 19.11.4.7 |
| 4683 |
ATCC TEST LABS LLP
| 8172626
| IS 17505 : Part 1 (2021) |
Specification for Thermosetting Insulated Fire Survival Cables for Fixed Installation having Low Emission of Smoke and Corrosive Gases when Affected by Fire for Working Voltages upto and including 1100 Vac and 1500 Vdc |
- |
140000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl. 7.3, Table 1 to 5 of IS 8130:2013 & IS:10810 (Part 5)-1984(Conductor Resistance Test) |
- |
1000 |
|
- |
| Cl. 7.1.2 of IS 8130 : 2013 & IS:10810 (Part 1)-1984(Annealing Test (for copper)) |
- |
1000 |
|
- |
| Cl. 7.1.1 of IS 8130:2013 & IS:10810 (Part 4)-1984(Persulphate Test for tinned copper) |
- |
3000 |
|
- |
| IS 191:2007 & IS 440(Copper purity test) |
- |
10000 |
|
- |
| Cl. 11,14,16, Table 4 and Table 6 of IS 17505 & IS:10810 (Part 6)-1984(Test for overall dimensions and thickness of insulation and sheath) |
- |
5000 |
|
- |
| Table 7 of IS 17505-1:2021, IS 3975:1999 & IS:10810 (Part 36)-1984(Diameter of armour Wire) |
- |
5000 |
|
- |
| Table 7 of IS 17505-1:2021, IS 3975:1999 & IS:10810 (Part 37)-1984(Tensile strength and elongation at break) |
- |
5000 |
|
- |
| Table 7 of IS 17505-1:2021, IS 3975:1999 & IS:10810 (Part 38)-1984(Torsion Test on galvanised steel wire for armouring) |
- |
5000 |
|
- |
| Table 7 of IS 17505-1:2021, IS 3975:1999 & IS:10810 (Part 39)-1984(Winding Test for Formed Wires) |
- |
5000 |
|
- |
| Table 7 of IS 17505-1:2021, IS 3975:1999 & IS:10810 (Part 40)-1984(Uniformity of Zinc coating on Round Steel Wires and Formed Steel Wires (Strips)) |
- |
5000 |
|
- |
| Table 7 of IS 17505-1:2021, IS 3975:1999 & IS:10810 (Part 41)-1984(Mass of Zinc coating on Round Steel Wires and Formed Steel Wires (Strips)) |
- |
5000 |
|
- |
| Table 7 of IS 17505-1:2021, IS 3975:1999 & IS:10810 (Part 42)-1984(Resistivity test) |
- |
5000 |
|
- |
| Table 1 and Table 2 of IS 17505 -1: 2021, IS:10810 (Part 7)-1984 & IS:10810 (Part 11)-1984(Tensile Strength and elongation at break before and after ageing.) |
- |
5000 |
|
- |
| Cl 18.2 of IS 17505-1:2021 & IS:10810 (Part 45)-1984(High voltage test) |
- |
5000 |
|
- |
| Table 1 of IS 17505-1 :2021 & IS:10810 (Part 43)-1984(Insulation Resistance) |
- |
5000 |
|
- |
| Cl. 18.6 of IS 17505-1:2021 & IS:10810 (Part 58)-1998(Oxygen index) |
- |
5000 |
|
- |
| Cl. 18.7 of IS 17505-1:2021 & IS:10810 (Part 64)-2003(Temperature Index) |
- |
5000 |
|
- |
| Table-1 & Table-2 of IS 17505-1:2021 & IS:10810 (Part 11)-1984(Ageing in air oven.) |
- |
5000 |
|
- |
| Specification for thermosetting insulated fire survival cables for fixed installation having low emission of smoke and corrosive gases when affected by fire for working voltages upto and including 1100 V A.C. and 1500 V D.C(Hot deformation) |
- |
5000 |
|
- |
| Table-1 & Annex-F (F.1, F.2, F.3 F.4) of IS 17505-1 :2021(pH) |
- |
10000 |
|
- |
| Table-1 & Annex-F (F.1, F.2, F.3 F.4) of IS 17505-1 :2021(Conductivity) |
- |
10000 |
|
- |
| Table-1 & Annex-F (F.1, F.2, F.3 F.4) of IS 17505-1 :2021(HCl and HBr) |
- |
10000 |
|
- |
| Table-1 & Annex-F (F.1, F.2, F.3 F.4) of IS 17505-1 :2021(Presence of Fluorine / Fluorine Content (if required)) |
- |
10000 |
|
- |
| Table 1 of IS 17505-1: 2021 & IS:10810 (Part 21)-1984(Cold impact test) |
- |
2000 |
|
- |
| Table 1 & 2 of IS 17505-1: 2021 & IS:10810 (Part 30)-1984(Hot set test) |
- |
2000 |
|
- |
| Table 1 & 2 of IS 17505-1: 2021 & IS:10810 (Part 13)-1984(Ozone Resistance test) |
- |
5000 |
|
- |
| Cl 18.5.1 of IS 17505-1 :2021 & IS:10810 (Part 61)-1988(Flame test on single cable) |
- |
2000 |
|
- |
| Table 1 of IS 17505-1:2021 & IS:10810 (Part 12)-1984(Shrinkage test) |
- |
2000 |
|
- |
| Cl 7 & Annex-F (F.1, F.2, F.3 F.4) of IS 17505-1 :2021(pH) |
- |
10000 |
|
- |
| Cl 7 & Annex-F (F.1, F.2, F.3 F.4) of IS 17505-1 :2021(Conductivity) |
- |
10000 |
|
- |
| Cl 7 & Annex-F (F.1, F.2, F.3 F.4) of IS 17505-1 :2021(HCl and HBr) |
- |
10000 |
|
- |
| Cl 7 & Annex-F (F.1, F.2, F.3 F.4) of IS 17505-1 :2021(Presence of Fluorine / Fluorine Content (if required)) |
- |
10000 |
|
- |
| Tabel 1 and 2 of IS 17505-1:2021 & IS:10810 (Part 7)-1984(Tensile strength and elongation at break.) |
- |
10000 |
|
- |
| Tabel 1 and 2 of IS 17505-1:2021 & IS:10810 (Part 11)-1984(Ageing in air oven.) |
- |
10000 |
|
- |
| Cl 18.6 of IS 17505-1: 2021 & IS:10810 (Part 58)-1998(Oxygen Index.) |
- |
5000 |
|
- |
| Cl 18.8 of IS 17505-1:2021 & IS:10810 (Part 64)-2003(Temperature Index) |
- |
5000 |
|
- |
| Table 1 & 2 of IS 17505-1: 2021 & IS:10810 (Part 13)-1984(Ozone resistance test) |
- |
5000 |
|
- |
| Table 2 of IS 17505-1:2021 & IS:10810 (Part 15)-1984(Hot deformation) |
- |
2000 |
|
- |
| Cl 7 & Annex-F (F.1, F.2, F.3 F.4) of IS 17505-1 :2021(pH) |
- |
10000 |
|
- |
| Cl 7 & Annex-F (F.1, F.2, F.3 F.4) of IS 17505-1 :2021(Conductivity) |
- |
10000 |
|
- |
| Cl 7 & Annex-F (F.1, F.2, F.3 F.4) of IS 17505-1 :2021(HCl and HBr) |
- |
10000 |
|
- |
| Cl 7 & Annex-F (F.1, F.2, F.3 F.4) of IS 17505-1 :2021(Presence of Fluorine / Fluorine Content (if required)) |
- |
10000 |
|
- |
| Table 1 of IS 17505-1:2021 & IS:10810 (Part 12)-1984(Shrinkage test) |
- |
2000 |
|
- |
| Cl 18.2of IS 17505-1:2021 & IS:10810 (Part 45)-1984.(High Voltage test.) |
- |
2000 |
|
- |
| Cl 18.5of IS 17505-1:2021 & IS:10810 (Part 53)-1984(Flammability Test) |
- |
2000 |
|
- |
| Table-2 of IS 17505-1:2021 & IS:10810 (Part 20)-1984(Cold bend test) |
- |
2000 |
|
- |
| Table-2 of IS 17505-1:2021 & IS:10810 (Part 21)-1984(Cold impact test) |
- |
2000 |
|
- |
| Cl 18.5 of IS 17505-1:2021 & IS:10810 (Part 61)-1988(Flammability Test) |
- |
2000 |
|
- |
| Cl 18.9 of IS 17505-1:2021(Water immersion test ( effect of water on sheath of cable)) |
- |
2000 |
|
- |
| Cl 18.8 of IS 17505-1:2021& IS:10810 (Part 63)-1993(Smoke density test) |
- |
10000 |
|
- |
| Cl. 3.5, 18.4 & Annex-E of IS 17505-1:2021(Circuit integrity test under fire) |
- |
50000 |
|
- |
| Cl. 17.1 Table 9 (iv) e(Heat Shock) |
- |
2000 |
|
- |
| Cl. 17.1 Table 9 (iv) h(Water absorption (Gravimetric)) |
- |
5000 |
|
- |
| Cl. 17.1 Table 9 (vii) b(Flame test on bunched cable) |
- |
20000 |
|
- |
| Cl. 17.1 Table 9 (ix)(Abrasion resistance test) |
- |
5000 |
|
- |
| Cl. 17.1 Table 9 (iv) m(Assessment of Halogen (HCl)) |
- |
5000 |
|
- |
| Cl. 7.3, Table 1 to 5 of IS 8130:2013 & IS:10810 (Part 5)-1984(Conductor Resistance Test) |
- |
5000 |
|
- |
| Cl. 7.1.2 of IS 8130 : 2013 & IS:10810 (Part 1)-1984(Annealing Test (for copper)) |
- |
5000 |
|
- |
| Cl. 7.1.1 of IS 8130:2013 & IS:10810 (Part 4)-1984(Persulphate Test for tinned copper) |
- |
5000 |
|
- |
| IS 191:2007 & IS 440(Copper purity test) |
- |
8000 |
|
- |
| Cl. 11,14,16, Table 4 and Table 6 of IS 17505 & IS:10810 (Part 6)-1984(Test for overall dimensions and thickness of insulation and sheath) |
- |
5000 |
|
- |
| Table 7 of IS 17505-1:2021, IS 3975:1999 & IS:10810 (Part 36)-1984(Diameter of armour Wire) |
- |
5000 |
|
- |
| Table 7 of IS 17505-1:2021, IS 3975:1999 & IS:10810 (Part 37)-1984(Tensile strength and elongation at break) |
- |
5000 |
|
- |
| Table 7 of IS 17505-1:2021, IS 3975:1999 & IS:10810 (Part 38)-1984(Torsion Test on galvanised steel wire for armouring) |
- |
5000 |
|
- |
| Table 7 of IS 17505-1:2021, IS 3975:1999 & IS:10810 (Part 39)-1984(Winding Test for Formed Wires) |
- |
5000 |
|
- |
| Table 7 of IS 17505-1:2021, IS 3975:1999 & IS:10810 (Part 40)-1984(Uniformity of Zinc coating on Round Steel Wires and Formed Steel Wires (Strips)) |
- |
5000 |
|
- |
| Table 7 of IS 17505-1:2021, IS 3975:1999 & IS:10810 (Part 41)-1984(Mass of Zinc coating on Round Steel Wires and Formed Steel Wires (Strips)) |
- |
5000 |
|
- |
| Table 7 of IS 17505-1:2021, IS 3975:1999 & IS:10810 (Part 42)-1984(Resistivity test) |
- |
5000 |
|
- |
| Table 1 and Table 2 of IS 17505 -1: 2021, IS:10810 (Part 7)-1984 & IS:10810 (Part 11)-1984(Tensile Strength and elongation at break before and after ageing.) |
- |
5000 |
|
- |
| Cl 18.2 of IS 17505-1:2021 & IS:10810 (Part 45)-1984(High voltage test) |
- |
5000 |
|
- |
| Table 1 of IS 17505-1 :2021 & IS:10810 (Part 43)-1984(Insulation Resistance) |
- |
5000 |
|
- |
| Cl. 18.6 of IS 17505-1:2021 & IS:10810 (Part 58)-1998(Oxygen index) |
- |
5000 |
|
- |
| Cl. 18.7 of IS 17505-1:2021 & IS:10810 (Part 64)-2003(Temperature Index) |
- |
5000 |
|
- |
| Table-1 & Table-2 of IS 17505-1:2021 & IS:10810 (Part 11)-1984(Ageing in air oven.) |
- |
5000 |
|
- |
| Specification for thermosetting insulated fire survival cables for fixed installation having low emission of smoke and corrosive gases when affected by fire for working voltages upto and including 1100 V A.C. and 1500 V D.C(Hot deformation) |
- |
5000 |
|
- |
| Table-1 & Annex-F (F.1, F.2, F.3 F.4) of IS 17505-1 :2021(pH) |
- |
5000 |
|
- |
| Table-1 & Annex-F (F.1, F.2, F.3 F.4) of IS 17505-1 :2021(Conductivity) |
- |
5000 |
|
- |
| Table-1 & Annex-F (F.1, F.2, F.3 F.4) of IS 17505-1 :2021(HCl and HBr) |
- |
5000 |
|
- |
| Table-1 & Annex-F (F.1, F.2, F.3 F.4) of IS 17505-1 :2021(Presence of Fluorine / Fluorine Content (if required)) |
- |
5000 |
|
- |
| Table 1 of IS 17505-1: 2021 & IS:10810 (Part 21)-1984(Cold impact test) |
- |
5000 |
|
- |
| Table 1 & 2 of IS 17505-1: 2021 & IS:10810 (Part 30)-1984(Hot set test) |
- |
5000 |
|
- |
| Table 1 & 2 of IS 17505-1: 2021 & IS:10810 (Part 13)-1984(Ozone Resistance test) |
- |
5000 |
|
- |
| Cl 18.5.1 of IS 17505-1 :2021 & IS:10810 (Part 61)-1988(Flame test on single cable) |
- |
5000 |
|
- |
| Table 1 of IS 17505-1:2021 & IS:10810 (Part 12)-1984(Shrinkage test) |
- |
5000 |
|
- |
| Cl 7 & Annex-F (F.1, F.2, F.3 F.4) of IS 17505-1 :2021(pH) |
- |
5000 |
|
- |
| Cl 7 & Annex-F (F.1, F.2, F.3 F.4) of IS 17505-1 :2021(Conductivity) |
- |
5000 |
|
- |
| Cl 7 & Annex-F (F.1, F.2, F.3 F.4) of IS 17505-1 :2021(HCl and HBr) |
- |
5000 |
|
- |
| Cl 7 & Annex-F (F.1, F.2, F.3 F.4) of IS 17505-1 :2021(Presence of Fluorine / Fluorine Content (if required)) |
- |
5000 |
|
- |
| Tabel 1 and 2 of IS 17505-1:2021 & IS:10810 (Part 7)-1984(Tensile strength and elongation at break.) |
- |
5000 |
|
- |
| Tabel 1 and 2 of IS 17505-1:2021 & IS:10810 (Part 11)-1984(Ageing in air oven.) |
- |
5000 |
|
- |
| Cl 18.6 of IS 17505-1: 2021 & IS:10810 (Part 58)-1998(Oxygen Index.) |
- |
5000 |
|
- |
| Cl 18.8 of IS 17505-1:2021 & IS:10810 (Part 64)-2003(Temperature Index) |
- |
5000 |
|
- |
| Table 1 & 2 of IS 17505-1: 2021 & IS:10810 (Part 13)-1984(Ozone resistance test) |
- |
5000 |
|
- |
| Table 2 of IS 17505-1:2021 & IS:10810 (Part 15)-1984(Hot deformation) |
- |
5000 |
|
- |
| Cl 7 & Annex-F (F.1, F.2, F.3 F.4) of IS 17505-1 :2021(pH) |
- |
5000 |
|
- |
| Cl 7 & Annex-F (F.1, F.2, F.3 F.4) of IS 17505-1 :2021(Conductivity) |
- |
5000 |
|
- |
| Cl 7 & Annex-F (F.1, F.2, F.3 F.4) of IS 17505-1 :2021(HCl and HBr) |
- |
5000 |
|
- |
| Cl 7 & Annex-F (F.1, F.2, F.3 F.4) of IS 17505-1 :2021(Presence of Fluorine / Fluorine Content (if required)) |
- |
5000 |
|
- |
| Table 1 of IS 17505-1:2021 & IS:10810 (Part 12)-1984(Shrinkage test) |
- |
5000 |
|
- |
| Cl 18.2of IS 17505-1:2021 & IS:10810 (Part 45)-1984.(High Voltage test.) |
- |
5000 |
|
- |
| Cl 18.5of IS 17505-1:2021 & IS:10810 (Part 53)-1984(Flammability Test) |
- |
5000 |
|
- |
| Table-2 of IS 17505-1:2021 & IS:10810 (Part 20)-1984(Cold bend test) |
- |
5000 |
|
- |
| Table-2 of IS 17505-1:2021 & IS:10810 (Part 21)-1984(Cold impact test) |
- |
5000 |
|
- |
| Cl 18.5 of IS 17505-1:2021 & IS:10810 (Part 61)-1988(Flammability Test) |
- |
5000 |
|
- |
| Cl 18.9 of IS 17505-1:2021(Water immersion test ( effect of water on sheath of cable)) |
- |
5000 |
|
- |
| Cl 18.8 of IS 17505-1:2021& IS:10810 (Part 63)-1993(Smoke density test) |
- |
5000 |
|
- |
| Cl. 3.5, 18.4 & Annex-E of IS 17505-1:2021(Circuit integrity test under fire) |
- |
5000 |
|
- |
| Cl. 17.1 Table 9 (iv) e(Heat Shock) |
- |
5000 |
|
- |
| Cl. 17.1 Table 9 (iv) h(Water absorption (Gravimetric)) |
- |
5000 |
|
- |
| Cl. 17.1 Table 9 (vii) b(Flame test on bunched cable) |
- |
5000 |
|
- |
| Cl. 17.1 Table 9 (ix)(Abrasion resistance test) |
- |
5000 |
|
- |
| Cl. 17.1 Table 9 (iv) m(Assessment of Halogen (HCl)) |
- |
5000 |
|
- |
| Cl. 7.3, Table 1 to 5 of IS 8130:2013 & IS:10810 (Part 5)-1984(Conductor Resistance Test) |
- |
5000 |
|
- |
| Cl. 7.1.2 of IS 8130 : 2013 & IS:10810 (Part 1)-1984(Annealing Test (for copper)) |
- |
5000 |
|
- |
| Cl. 7.1.1 of IS 8130:2013 & IS:10810 (Part 4)-1984(Persulphate Test for tinned copper) |
- |
5000 |
|
- |
| IS 191:2007 & IS 440(Copper purity test) |
- |
5000 |
|
- |
| Cl. 11,14,16, Table 4 and Table 6 of IS 17505 & IS:10810 (Part 6)-1984(Test for overall dimensions and thickness of insulation and sheath) |
- |
5000 |
|
- |
| Table 7 of IS 17505-1:2021, IS 3975:1999 & IS:10810 (Part 36)-1984(Diameter of armour Wire) |
- |
5000 |
|
- |
| Table 7 of IS 17505-1:2021, IS 3975:1999 & IS:10810 (Part 37)-1984(Tensile strength and elongation at break) |
- |
5000 |
|
- |
| Table 7 of IS 17505-1:2021, IS 3975:1999 & IS:10810 (Part 38)-1984(Torsion Test on galvanised steel wire for armouring) |
- |
5000 |
|
- |
| Table 7 of IS 17505-1:2021, IS 3975:1999 & IS:10810 (Part 39)-1984(Winding Test for Formed Wires) |
- |
5000 |
|
- |
| Table 7 of IS 17505-1:2021, IS 3975:1999 & IS:10810 (Part 40)-1984(Uniformity of Zinc coating on Round Steel Wires and Formed Steel Wires (Strips)) |
- |
5000 |
|
- |
| Table 7 of IS 17505-1:2021, IS 3975:1999 & IS:10810 (Part 41)-1984(Mass of Zinc coating on Round Steel Wires and Formed Steel Wires (Strips)) |
- |
5000 |
|
- |
| Table 7 of IS 17505-1:2021, IS 3975:1999 & IS:10810 (Part 42)-1984(Resistivity test) |
- |
5000 |
|
- |
| Table 1 and Table 2 of IS 17505 -1: 2021, IS:10810 (Part 7)-1984 & IS:10810 (Part 11)-1984(Tensile Strength and elongation at break before and after ageing.) |
- |
5000 |
|
- |
| Cl 18.2 of IS 17505-1:2021 & IS:10810 (Part 45)-1984(High voltage test) |
- |
5000 |
|
- |
| Table 1 of IS 17505-1 :2021 & IS:10810 (Part 43)-1984(Insulation Resistance) |
- |
5000 |
|
- |
| Cl. 18.6 of IS 17505-1:2021 & IS:10810 (Part 58)-1998(Oxygen index) |
- |
5000 |
|
- |
| Cl. 18.7 of IS 17505-1:2021 & IS:10810 (Part 64)-2003(Temperature Index) |
- |
5000 |
|
- |
| Table-1 & Table-2 of IS 17505-1:2021 & IS:10810 (Part 11)-1984(Ageing in air oven.) |
- |
5000 |
|
- |
| Specification for thermosetting insulated fire survival cables for fixed installation having low emission of smoke and corrosive gases when affected by fire for working voltages upto and including 1100 V A.C. and 1500 V D.C(Hot deformation) |
- |
5000 |
|
- |
| Table-1 & Annex-F (F.1, F.2, F.3 F.4) of IS 17505-1 :2021(pH) |
- |
5000 |
|
- |
| Table-1 & Annex-F (F.1, F.2, F.3 F.4) of IS 17505-1 :2021(Conductivity) |
- |
5000 |
|
- |
| Table-1 & Annex-F (F.1, F.2, F.3 F.4) of IS 17505-1 :2021(HCl and HBr) |
- |
5000 |
|
- |
| Table-1 & Annex-F (F.1, F.2, F.3 F.4) of IS 17505-1 :2021(Presence of Fluorine / Fluorine Content (if required)) |
- |
5000 |
|
- |
| Table 1 of IS 17505-1: 2021 & IS:10810 (Part 21)-1984(Cold impact test) |
- |
5000 |
|
- |
| Table 1 & 2 of IS 17505-1: 2021 & IS:10810 (Part 30)-1984(Hot set test) |
- |
5000 |
|
- |
| Table 1 & 2 of IS 17505-1: 2021 & IS:10810 (Part 13)-1984(Ozone Resistance test) |
- |
5000 |
|
- |
| Cl 18.5.1 of IS 17505-1 :2021 & IS:10810 (Part 61)-1988(Flame test on single cable) |
- |
5000 |
|
- |
| Table 1 of IS 17505-1:2021 & IS:10810 (Part 12)-1984(Shrinkage test) |
- |
5000 |
|
- |
| Cl 7 & Annex-F (F.1, F.2, F.3 F.4) of IS 17505-1 :2021(pH) |
- |
5000 |
|
- |
| Cl 7 & Annex-F (F.1, F.2, F.3 F.4) of IS 17505-1 :2021(Conductivity) |
- |
5000 |
|
- |
| Cl 7 & Annex-F (F.1, F.2, F.3 F.4) of IS 17505-1 :2021(HCl and HBr) |
- |
5000 |
|
- |
| Cl 7 & Annex-F (F.1, F.2, F.3 F.4) of IS 17505-1 :2021(Presence of Fluorine / Fluorine Content (if required)) |
- |
5000 |
|
- |
| Tabel 1 and 2 of IS 17505-1:2021 & IS:10810 (Part 7)-1984(Tensile strength and elongation at break.) |
- |
5000 |
|
- |
| Tabel 1 and 2 of IS 17505-1:2021 & IS:10810 (Part 11)-1984(Ageing in air oven.) |
- |
5000 |
|
- |
| Cl 18.6 of IS 17505-1: 2021 & IS:10810 (Part 58)-1998(Oxygen Index.) |
- |
5000 |
|
- |
| Cl 18.8 of IS 17505-1:2021 & IS:10810 (Part 64)-2003(Temperature Index) |
- |
5000 |
|
- |
| Table 1 & 2 of IS 17505-1: 2021 & IS:10810 (Part 13)-1984(Ozone resistance test) |
- |
5000 |
|
- |
| Table 2 of IS 17505-1:2021 & IS:10810 (Part 15)-1984(Hot deformation) |
- |
5000 |
|
- |
| Cl 7 & Annex-F (F.1, F.2, F.3 F.4) of IS 17505-1 :2021(pH) |
- |
5000 |
|
- |
| Cl 7 & Annex-F (F.1, F.2, F.3 F.4) of IS 17505-1 :2021(Conductivity) |
- |
5000 |
|
- |
| Cl 7 & Annex-F (F.1, F.2, F.3 F.4) of IS 17505-1 :2021(HCl and HBr) |
- |
5000 |
|
- |
| Cl 7 & Annex-F (F.1, F.2, F.3 F.4) of IS 17505-1 :2021(Presence of Fluorine / Fluorine Content (if required)) |
- |
5000 |
|
- |
| Table 1 of IS 17505-1:2021 & IS:10810 (Part 12)-1984(Shrinkage test) |
- |
5000 |
|
- |
| Cl 18.2of IS 17505-1:2021 & IS:10810 (Part 45)-1984.(High Voltage test.) |
- |
5000 |
|
- |
| Cl 18.5of IS 17505-1:2021 & IS:10810 (Part 53)-1984(Flammability Test) |
- |
5000 |
|
- |
| Table-2 of IS 17505-1:2021 & IS:10810 (Part 20)-1984(Cold bend test) |
- |
5000 |
|
- |
| Table-2 of IS 17505-1:2021 & IS:10810 (Part 21)-1984(Cold impact test) |
- |
5000 |
|
- |
| Cl 18.5 of IS 17505-1:2021 & IS:10810 (Part 61)-1988(Flammability Test) |
- |
5000 |
|
- |
| Cl 18.9 of IS 17505-1:2021(Water immersion test ( effect of water on sheath of cable)) |
- |
5000 |
|
- |
| Cl 18.8 of IS 17505-1:2021& IS:10810 (Part 63)-1993(Smoke density test) |
- |
5000 |
|
- |
| Cl. 3.5, 18.4 & Annex-E of IS 17505-1:2021(Circuit integrity test under fire) |
- |
5000 |
|
- |
| Cl. 17.1 Table 9 (iv) e(Heat Shock) |
- |
5000 |
|
- |
| Cl. 17.1 Table 9 (iv) h(Water absorption (Gravimetric)) |
- |
5000 |
|
- |
| Cl. 17.1 Table 9 (vii) b(Flame test on bunched cable) |
- |
5000 |
|
- |
| Cl. 17.1 Table 9 (ix)(Abrasion resistance test) |
- |
5000 |
|
- |
| Cl. 17.1 Table 9 (iv) m(Assessment of Halogen (HCl)) |
- |
5000 |
|
- |
| Cl. 7.3, Table 1 to 5 of IS 8130:2013 & IS:10810 (Part 5)-1984(Conductor Resistance Test) |
- |
- |
|
- |
| Cl. 7.1.2 of IS 8130 : 2013 & IS:10810 (Part 1)-1984(Annealing Test (for copper)) |
- |
- |
|
- |
| Cl. 7.1.1 of IS 8130:2013 & IS:10810 (Part 4)-1984(Persulphate Test for tinned copper) |
- |
- |
|
- |
| IS 191:2007 & IS 440(Copper purity test) |
- |
- |
|
- |
| Cl. 11,14,16, Table 4 and Table 6 of IS 17505 & IS:10810 (Part 6)-1984(Test for overall dimensions and thickness of insulation and sheath) |
- |
- |
|
- |
| Table 7 of IS 17505-1:2021, IS 3975:1999 & IS:10810 (Part 36)-1984(Diameter of armour Wire) |
- |
- |
|
- |
| Table 7 of IS 17505-1:2021, IS 3975:1999 & IS:10810 (Part 37)-1984(Tensile strength and elongation at break) |
- |
- |
|
- |
| Table 7 of IS 17505-1:2021, IS 3975:1999 & IS:10810 (Part 38)-1984(Torsion Test on galvanised steel wire for armouring) |
- |
- |
|
- |
| Table 7 of IS 17505-1:2021, IS 3975:1999 & IS:10810 (Part 39)-1984(Winding Test for Formed Wires) |
- |
- |
|
- |
| Table 7 of IS 17505-1:2021, IS 3975:1999 & IS:10810 (Part 40)-1984(Uniformity of Zinc coating on Round Steel Wires and Formed Steel Wires (Strips)) |
- |
- |
|
- |
| Table 7 of IS 17505-1:2021, IS 3975:1999 & IS:10810 (Part 41)-1984(Mass of Zinc coating on Round Steel Wires and Formed Steel Wires (Strips)) |
- |
- |
|
- |
| Table 7 of IS 17505-1:2021, IS 3975:1999 & IS:10810 (Part 42)-1984(Resistivity test) |
- |
- |
|
- |
| Table 1 and Table 2 of IS 17505 -1: 2021, IS:10810 (Part 7)-1984 & IS:10810 (Part 11)-1984(Tensile Strength and elongation at break before and after ageing.) |
- |
- |
|
- |
| Cl 18.2 of IS 17505-1:2021 & IS:10810 (Part 45)-1984(High voltage test) |
- |
- |
|
- |
| Table 1 of IS 17505-1 :2021 & IS:10810 (Part 43)-1984(Insulation Resistance) |
- |
- |
|
- |
| Cl. 18.6 of IS 17505-1:2021 & IS:10810 (Part 58)-1998(Oxygen index) |
- |
- |
|
- |
| Cl. 18.7 of IS 17505-1:2021 & IS:10810 (Part 64)-2003(Temperature Index) |
- |
- |
|
- |
| Table-1 & Table-2 of IS 17505-1:2021 & IS:10810 (Part 11)-1984(Ageing in air oven.) |
- |
- |
|
- |
| Specification for thermosetting insulated fire survival cables for fixed installation having low emission of smoke and corrosive gases when affected by fire for working voltages upto and including 1100 V A.C. and 1500 V D.C(Hot deformation) |
- |
- |
|
- |
| Table-1 & Annex-F (F.1, F.2, F.3 F.4) of IS 17505-1 :2021(pH) |
- |
- |
|
- |
| Table-1 & Annex-F (F.1, F.2, F.3 F.4) of IS 17505-1 :2021(Conductivity) |
- |
- |
|
- |
| Table-1 & Annex-F (F.1, F.2, F.3 F.4) of IS 17505-1 :2021(HCl and HBr) |
- |
- |
|
- |
| Table-1 & Annex-F (F.1, F.2, F.3 F.4) of IS 17505-1 :2021(Presence of Fluorine / Fluorine Content (if required)) |
- |
- |
|
- |
| Table 1 of IS 17505-1: 2021 & IS:10810 (Part 21)-1984(Cold impact test) |
- |
- |
|
- |
| Table 1 & 2 of IS 17505-1: 2021 & IS:10810 (Part 30)-1984(Hot set test) |
- |
- |
|
- |
| Table 1 & 2 of IS 17505-1: 2021 & IS:10810 (Part 13)-1984(Ozone Resistance test) |
- |
- |
|
- |
| Cl 18.5.1 of IS 17505-1 :2021 & IS:10810 (Part 61)-1988(Flame test on single cable) |
- |
- |
|
- |
| Table 1 of IS 17505-1:2021 & IS:10810 (Part 12)-1984(Shrinkage test) |
- |
- |
|
- |
| Cl 7 & Annex-F (F.1, F.2, F.3 F.4) of IS 17505-1 :2021(pH) |
- |
- |
|
- |
| Cl 7 & Annex-F (F.1, F.2, F.3 F.4) of IS 17505-1 :2021(Conductivity) |
- |
- |
|
- |
| Cl 7 & Annex-F (F.1, F.2, F.3 F.4) of IS 17505-1 :2021(HCl and HBr) |
- |
- |
|
- |
| Cl 7 & Annex-F (F.1, F.2, F.3 F.4) of IS 17505-1 :2021(Presence of Fluorine / Fluorine Content (if required)) |
- |
- |
|
- |
| Tabel 1 and 2 of IS 17505-1:2021 & IS:10810 (Part 7)-1984(Tensile strength and elongation at break.) |
- |
- |
|
- |
| Tabel 1 and 2 of IS 17505-1:2021 & IS:10810 (Part 11)-1984(Ageing in air oven.) |
- |
- |
|
- |
| Cl 18.6 of IS 17505-1: 2021 & IS:10810 (Part 58)-1998(Oxygen Index.) |
- |
- |
|
- |
| Cl 18.8 of IS 17505-1:2021 & IS:10810 (Part 64)-2003(Temperature Index) |
- |
- |
|
- |
| Table 1 & 2 of IS 17505-1: 2021 & IS:10810 (Part 13)-1984(Ozone resistance test) |
- |
- |
|
- |
| Table 2 of IS 17505-1:2021 & IS:10810 (Part 15)-1984(Hot deformation) |
- |
- |
|
- |
| Cl 7 & Annex-F (F.1, F.2, F.3 F.4) of IS 17505-1 :2021(pH) |
- |
- |
|
- |
| Cl 7 & Annex-F (F.1, F.2, F.3 F.4) of IS 17505-1 :2021(Conductivity) |
- |
- |
|
- |
| Cl 7 & Annex-F (F.1, F.2, F.3 F.4) of IS 17505-1 :2021(HCl and HBr) |
- |
- |
|
- |
| Cl 7 & Annex-F (F.1, F.2, F.3 F.4) of IS 17505-1 :2021(Presence of Fluorine / Fluorine Content (if required)) |
- |
- |
|
- |
| Table 1 of IS 17505-1:2021 & IS:10810 (Part 12)-1984(Shrinkage test) |
- |
- |
|
- |
| Cl 18.2of IS 17505-1:2021 & IS:10810 (Part 45)-1984.(High Voltage test.) |
- |
- |
|
- |
| Cl 18.5of IS 17505-1:2021 & IS:10810 (Part 53)-1984(Flammability Test) |
- |
- |
|
- |
| Table-2 of IS 17505-1:2021 & IS:10810 (Part 20)-1984(Cold bend test) |
- |
- |
|
- |
| Table-2 of IS 17505-1:2021 & IS:10810 (Part 21)-1984(Cold impact test) |
- |
- |
|
- |
| Cl 18.5 of IS 17505-1:2021 & IS:10810 (Part 61)-1988(Flammability Test) |
- |
- |
|
- |
| Cl 18.9 of IS 17505-1:2021(Water immersion test ( effect of water on sheath of cable)) |
- |
- |
|
- |
| Cl 18.8 of IS 17505-1:2021& IS:10810 (Part 63)-1993(Smoke density test) |
- |
- |
|
- |
| Cl. 3.5, 18.4 & Annex-E of IS 17505-1:2021(Circuit integrity test under fire) |
- |
- |
|
- |
| Cl. 17.1 Table 9 (iv) e(Heat Shock) |
- |
- |
|
- |
| Cl. 17.1 Table 9 (iv) h(Water absorption (Gravimetric)) |
- |
- |
|
- |
| Cl. 17.1 Table 9 (vii) b(Flame test on bunched cable) |
- |
- |
|
- |
| Cl. 17.1 Table 9 (ix)(Abrasion resistance test) |
- |
- |
|
- |
| Cl. 17.1 Table 9 (iv) m(Assessment of Halogen (HCl)) |
- |
- |
|
- |
|
- |
- Included w.e.f.19.06.2025 |
| 4684 |
ATCC TEST LABS LLP
| 8172626
| IS 17048 (2018) |
Halogen free flame retardant (HFFR) cables for working voltages up to and including 1 100 Volts - Specification |
- |
120000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4.1.1 a) (Conductor : Material ) |
- |
3000 |
|
- |
| 4.1.1 b) (Material : Seperator tape ) |
- |
1000 |
|
- |
| 4.1.1 d) , 11.1, 12.1, 13.1,14.1(Class of conductor ) |
- |
1000 |
|
- |
| 4.1.1 e) (Shape of conductor ) |
- |
1000 |
|
- |
| 4.1.1 f) (Nominal size of conductor ) |
- |
1000 |
|
- |
| 4.2.1, 11.2, 12.2, 13.2, 14.2(Insulation : Material ) |
- |
1000 |
|
- |
| 4.2.2, 11.2, 12.2, 13.2, 14.2(Insulation : Application ) |
- |
1000 |
|
- |
| 4.2.3,11.2, 12.2, 13.2(Thickness of insulation - Avearge : IS 10810 ( Part 6 )) |
- |
1000 |
|
- |
| 4.2.3, 11.2, 12.2, 13.2, 14.2(Thickness of insulation - miniumum : IS 10810 ( Part 6 )) |
- |
1000 |
|
- |
| 4.2.4(Insulation : Tensile stregth ( Before ageing)-IS 10810 (Part 7) ) |
- |
1000 |
|
- |
| 4.2.4(Insulation : Elongation ( Before ageing) -IS 10810 (Part 7)) |
- |
1000 |
|
- |
| 4.2.4(Insulation : Tensile stregth ( After ageing) - IS 10810 (Part 7) ) |
- |
3000 |
|
- |
| 4.2.5(Insulation : Tensile stregth variation ( After ageing) - IS 10810 (Part 7) ) |
- |
3000 |
|
- |
| 4.2.4(Insulation : Elongation (after ageing) - IS 10810 (Part 7) ) |
- |
3000 |
|
- |
| 4.2.5(Insulation : Elongation variation (after ageing) - IS 10810 (Part 7) ) |
- |
3000 |
|
- |
| 4.3(Fillers) |
- |
1000 |
|
- |
| 4.4(Binder Tape) |
- |
1000 |
|
- |
| 4.5.1,13.4, 14.4(Sheath : Compound ) |
- |
1000 |
|
- |
| 4.5.2, 13.4, 14.4(Sheath : Application) |
- |
1000 |
|
- |
| 4.5.3,13.4, 14.4(Thickness of sheath - Average : IS 10810 (Part 6)) |
- |
1000 |
|
- |
| 4.5.3,13.4, 14.4(Thickness of sheath - Minimum : IS 10810 (Part 6)) |
- |
1000 |
|
- |
| 4.5.4, 13.4(Sheath : Tensile stregth ( Before ageing)-IS 10810 (Part 7) ) |
- |
1000 |
|
- |
| 4.5.4,13.4(Sheath : Elongation ( Before ageing) -IS 10810 (Part 7)) |
- |
1000 |
|
- |
| 4.5.4, 13.4, 14.4(Sheath : Tensile stregth ( After ageing) - IS 10810 (Part 7) ) |
- |
3000 |
|
- |
| 4.5.5, 13.4, 14.4(Sheath : Tensile stregth variation ( After ageing) - IS 10810 (Part 7) ) |
- |
3000 |
|
- |
| 4.5.4, 13.4, 14.4(Sheath : Elongation (after ageing) - IS 10810 (Part 7) ) |
- |
3000 |
|
- |
| 4.5.5, 13.4,14.4(Sheath : Elongation variation (after ageing) - IS 10810 (Part 7) ) |
- |
3000 |
|
- |
| 4.5.5, 11.3, 12.3, 13.6, 14.6(Overall Dimensions) |
- |
1000 |
|
- |
| 4.5.5.1, 11.3, 12.3,13.5, 14.5(Ovality) |
- |
1000 |
|
- |
| 4.5.6, 13.4(Colour of Sheath) |
- |
1000 |
|
- |
| 5.1(High Voltage Test (at Room Temperature)) |
- |
1000 |
|
- |
| 5.2(Spark Test (Routine Test)) |
- |
1000 |
|
- |
| 5.3(Flammability Test- IS 10810 (Part 53).) |
- |
1000 |
|
- |
| 5.4(Oxygen Index Test- IS 10810 (Part 58)) |
- |
5000 |
|
- |
| 5.5(Temperature Index-IS 10810 (Part 64).) |
- |
3000 |
|
- |
| 5.6(Smoke Density-IS 10810 (Part 63).) |
- |
5000 |
|
- |
| 5.7(Assessment of Halogen- Table 1 of Annex D) |
- |
3000 |
|
- |
| 5.1(Persulphate Test- IS 10810 (Part 4).) |
- |
1000 |
|
- |
| 5.11(Flame Retardant Test- IS 10810 (Part 61),) |
- |
1000 |
|
- |
| 5.12(Hot Set Test- IS 10810 (Part 30).) |
- |
1000 |
|
- |
| 5.12(Permanent Set - IS 10810 (Part 30).) |
- |
1000 |
|
- |
| 5.13(Water Immersion Test (Effect of Water on Sheath) : Tensile strength -IS 10810 (Part 7).) |
- |
5000 |
|
- |
| 5.13(Water Immersion Test (Effect of Water on Sheath) : Elogation -IS 10810 (Part 7).) |
- |
3000 |
|
- |
| 5.14(Ozone Resistance Test -IS 10810 (Part 13 )) |
- |
12000 |
|
- |
| 5.15(Cold Bend Test-IS 10810 (Part 20).) |
- |
1000 |
|
- |
| 5.16(Cold Impact Test- IS 10810 (Part 21).) |
- |
1000 |
|
- |
| 6.1, Table 1(CORE IDENTIFICATION) |
- |
1000 |
|
- |
| 6.2(Core Identification by Numbers) |
- |
1000 |
|
- |
| 6.2.1(Preferred Arrangement of Marking) |
- |
1000 |
|
- |
| 6.2.2(Durability) |
- |
1000 |
|
- |
| 7.0(CABLE CODE) |
- |
1000 |
|
- |
| 9.0( IDENTIFICATION) |
- |
1000 |
|
- |
| 10.1(Packing ) |
- |
1000 |
|
- |
| 10.2(marking) |
- |
1000 |
|
- |
| 10.2.1(Standards marking) |
- |
1000 |
|
- |
| 13.3, 14.3(assembly of cores ) |
- |
1000 |
|
- |
| 6.1(General Requirements) |
- |
1000 |
|
- |
| 6.1.1(Colour Combination Green Yellow) |
- |
1000 |
|
- |
| 12.1(Conductor) |
- |
1000 |
|
- |
| 12.2, Table 4(insulation) |
- |
1000 |
|
- |
| Table 4(Copper Purity test) |
- |
5000 |
|
- |
| 4.3.1 (e)(Fluorine content test (Fillers)) |
- |
3000 |
|
- |
| 4.3.1 (d)(Presence of fluorine test (Fillers)) |
- |
10000 |
|
- |
| 4.3.1 (c)(Conductivity test (Fillers)) |
- |
3000 |
|
- |
| 4.3.1 (b)(pH test (Fillers)) |
- |
10000 |
|
- |
| 4.3.1 (a)(HCl test (Fillers)) |
- |
3000 |
|
- |
| 5.7 (a)(HCl test (Assessment of halogen test)) |
- |
3000 |
|
- |
| 5.7 (b)(pH test (Assessment of halogen test)) |
- |
2000 |
|
- |
| 5.7 (c)(Conductivity test (Assessment of halogen test)) |
- |
10000 |
|
- |
| 5.7 (d)(Presence of fluorine test (Assessment of halogen test)) |
- |
3000 |
|
- |
| 5.7 (e)(Fluorine content test (Assessment of halogen test)) |
- |
5000 |
|
- |
| Table 2 ,( Clause 11.4, 12.4, 13.7 14.7 and 15.7 )(Insulation Resistance) |
- |
3000 |
|
- |
| "Table 2 ( Clause 11.4, 12.4, 13.7 14.7 and 15.7 )"(Conductor Resistance) |
- |
3000 |
|
- |
| Table 2 , Clause .5.13(Water immersion test (Effect of water on sheath) - TS Variation of Sheath) |
- |
3000 |
|
- |
| Table 2 , Clause 5.13(Water immersion test (Effect of water on sheath) - Elongation Variation of Sheath) |
- |
3000 |
|
- |
| "Table 2 ( Clause 11.4, 12.4, 13.7 14.7 and 15.7 )"(Hot Deformation) |
- |
3000 |
|
- |
| Table 2, III.a.ii(Annealing test (for Cu,
before stranding)) |
- |
1000 |
|
- |
| Table 2, II.a, b(Wrapping test before
stranding (for Al)) |
- |
1000 |
|
- |
| Cl.4.2.1 & Annex A(Insulation Resistance Constant at Rated Temperature (70°C)) |
- |
3000 |
|
- |
| Table 2, III a (i)(Conductor Resistance) |
- |
3000 |
|
- |
| Annex A(Hot Deformation) |
- |
3000 |
|
- |
| 6.1, Table 1(CORE IDENTIFICATION) |
- |
1000 |
|
- |
| 6.1(General Requirements) |
- |
1000 |
|
- |
| 6.1.1(Colour Combination Green Yellow) |
- |
1000 |
|
- |
| 12.1(Conductor) |
- |
1000 |
|
- |
| 12.2, Table 4(insulation) |
- |
1000 |
|
- |
| Table 4(Copper Purity test) |
- |
5000 |
|
- |
| 4.3.1 (e)(Fluorine content test (Fillers)) |
- |
10000 |
|
- |
| 4.3.1 (d)(Presence of fluorine test (Fillers)) |
- |
10000 |
|
- |
| 4.3.1 (c)(Conductivity test (Fillers)) |
- |
10000 |
|
- |
| 4.3.1 (b)(pH test (Fillers)) |
- |
3000 |
|
- |
| 4.3.1 (a)(HCl test (Fillers)) |
- |
10000 |
|
- |
| 5.7 (a)(HCl test (Assessment of halogen test)) |
- |
3000 |
|
- |
| 5.7 (b)(pH test (Assessment of halogen test)) |
- |
3000 |
|
- |
| 5.7 (c)(Conductivity test (Assessment of halogen test)) |
- |
3000 |
|
- |
| 5.7 (d)(Presence of fluorine test (Assessment of halogen test)) |
- |
10000 |
|
- |
| 5.7 (e)(Fluorine content test (Assessment of halogen test)) |
- |
3000 |
|
- |
| Table 2 ,( Clause 11.4, 12.4, 13.7 14.7 and 15.7 )(Insulation Resistance) |
- |
3000 |
|
- |
| "Table 2 ( Clause 11.4, 12.4, 13.7 14.7 and 15.7 )"(Conductor Resistance) |
- |
3000 |
|
- |
| Table 2 , Clause .5.13(Water immersion test (Effect of water on sheath) - TS Variation of Sheath) |
- |
5000 |
|
- |
| Table 2 , Clause 5.13(Water immersion test (Effect of water on sheath) - Elongation Variation of Sheath) |
- |
5000 |
|
- |
| "Table 2 ( Clause 11.4, 12.4, 13.7 14.7 and 15.7 )"(Hot Deformation) |
- |
3000 |
|
- |
| Table 2, III.a.ii(Annealing test (for Cu,
before stranding)) |
- |
1000 |
|
- |
| Table 2, II.a, b(Wrapping test before
stranding (for Al)) |
- |
1000 |
|
- |
| Cl.4.2.1 & Annex A(Insulation Resistance Constant at Rated Temperature (70°C)) |
- |
3000 |
|
- |
| Table 2, III a (i)(Conductor Resistance) |
- |
3000 |
|
- |
| Annex A(Hot Deformation) |
- |
3000 |
|
- |
| 6.1, Table 1(CORE IDENTIFICATION) |
- |
1000 |
|
- |
| 6.1(General Requirements) |
- |
1000 |
|
- |
| 6.1.1(Colour Combination Green Yellow) |
- |
1000 |
|
- |
| 12.1(Conductor) |
- |
1000 |
|
- |
| 12.2, Table 4(insulation) |
- |
2000 |
|
- |
| Table 4(Copper Purity test) |
- |
5000 |
|
- |
| 4.3.1 (e)(Fluorine content test (Fillers)) |
- |
10000 |
|
- |
| 4.3.1 (d)(Presence of fluorine test (Fillers)) |
- |
3000 |
|
- |
| 4.3.1 (c)(Conductivity test (Fillers)) |
- |
3000 |
|
- |
| 4.3.1 (b)(pH test (Fillers)) |
- |
3000 |
|
- |
| 4.3.1 (a)(HCl test (Fillers)) |
- |
3000 |
|
- |
| 5.7 (a)(HCl test (Assessment of halogen test)) |
- |
3000 |
|
- |
| 5.7 (b)(pH test (Assessment of halogen test)) |
- |
5000 |
|
- |
| 5.7 (c)(Conductivity test (Assessment of halogen test)) |
- |
5000 |
|
- |
| 5.7 (d)(Presence of fluorine test (Assessment of halogen test)) |
- |
5000 |
|
- |
| 5.7 (e)(Fluorine content test (Assessment of halogen test)) |
- |
5000 |
|
- |
| Table 2 ,( Clause 11.4, 12.4, 13.7 14.7 and 15.7 )(Insulation Resistance) |
- |
5000 |
|
- |
| "Table 2 ( Clause 11.4, 12.4, 13.7 14.7 and 15.7 )"(Conductor Resistance) |
- |
5000 |
|
- |
| Table 2 , Clause .5.13(Water immersion test (Effect of water on sheath) - TS Variation of Sheath) |
- |
5000 |
|
- |
| Table 2 , Clause 5.13(Water immersion test (Effect of water on sheath) - Elongation Variation of Sheath) |
- |
5000 |
|
- |
| "Table 2 ( Clause 11.4, 12.4, 13.7 14.7 and 15.7 )"(Hot Deformation) |
- |
5000 |
|
- |
| Table 2, III.a.ii(Annealing test (for Cu,
before stranding)) |
- |
5000 |
|
- |
| Table 2, II.a, b(Wrapping test before
stranding (for Al)) |
- |
1000 |
|
- |
| Cl.4.2.1 & Annex A(Insulation Resistance Constant at Rated Temperature (70°C)) |
- |
1000 |
|
- |
| Table 2, III a (i)(Conductor Resistance) |
- |
2000 |
|
- |
| Annex A(Hot Deformation) |
- |
2000 |
|
- |
| 6.1, Table 1(CORE IDENTIFICATION) |
- |
1000 |
|
- |
| 6.1(General Requirements) |
- |
1000 |
|
- |
| 6.1.1(Colour Combination Green Yellow) |
- |
1000 |
|
- |
| 12.1(Conductor) |
- |
1000 |
|
- |
| 12.2, Table 4(insulation) |
- |
1000 |
|
- |
| Table 4(Copper Purity test) |
- |
10000 |
|
- |
| 4.3.1 (e)(Fluorine content test (Fillers)) |
- |
10000 |
|
- |
| 4.3.1 (d)(Presence of fluorine test (Fillers)) |
- |
5000 |
|
- |
| 4.3.1 (c)(Conductivity test (Fillers)) |
- |
5000 |
|
- |
| 4.3.1 (b)(pH test (Fillers)) |
- |
5000 |
|
- |
| 4.3.1 (a)(HCl test (Fillers)) |
- |
5000 |
|
- |
| 5.7 (a)(HCl test (Assessment of halogen test)) |
- |
5000 |
|
- |
| 5.7 (b)(pH test (Assessment of halogen test)) |
- |
5000 |
|
- |
| 5.7 (c)(Conductivity test (Assessment of halogen test)) |
- |
5000 |
|
- |
| 5.7 (d)(Presence of fluorine test (Assessment of halogen test)) |
- |
5000 |
|
- |
| 5.7 (e)(Fluorine content test (Assessment of halogen test)) |
- |
5000 |
|
- |
| Table 2 ,( Clause 11.4, 12.4, 13.7 14.7 and 15.7 )(Insulation Resistance) |
- |
2000 |
|
- |
| "Table 2 ( Clause 11.4, 12.4, 13.7 14.7 and 15.7 )"(Conductor Resistance) |
- |
2000 |
|
- |
| Table 2 , Clause .5.13(Water immersion test (Effect of water on sheath) - TS Variation of Sheath) |
- |
5000 |
|
- |
| Table 2 , Clause 5.13(Water immersion test (Effect of water on sheath) - Elongation Variation of Sheath) |
- |
5000 |
|
- |
| "Table 2 ( Clause 11.4, 12.4, 13.7 14.7 and 15.7 )"(Hot Deformation) |
- |
2000 |
|
- |
| Table 2, III.a.ii(Annealing test (for Cu,
before stranding)) |
- |
2000 |
|
- |
| Table 2, II.a, b(Wrapping test before
stranding (for Al)) |
- |
2000 |
|
- |
| Cl.4.2.1 & Annex A(Insulation Resistance Constant at Rated Temperature (70°C)) |
- |
5000 |
|
- |
| Table 2, III a (i)(Conductor Resistance) |
- |
5000 |
|
- |
| Annex A(Hot Deformation) |
- |
2000 |
|
- |
| 6.1, Table 1(CORE IDENTIFICATION) |
- |
2000 |
|
- |
| 6.1(General Requirements) |
- |
1000 |
|
- |
| 6.1.1(Colour Combination Green Yellow) |
- |
2000 |
|
- |
| 12.1(Conductor) |
- |
2000 |
|
- |
| 12.2, Table 4(insulation) |
- |
2000 |
|
- |
| Table 4(Copper Purity test) |
- |
4000 |
|
- |
| 4.3.1 (e)(Fluorine content test (Fillers)) |
- |
2000 |
|
- |
| 4.3.1 (d)(Presence of fluorine test (Fillers)) |
- |
2000 |
|
- |
| 4.3.1 (c)(Conductivity test (Fillers)) |
- |
2000 |
|
- |
| 4.3.1 (b)(pH test (Fillers)) |
- |
2000 |
|
- |
| 4.3.1 (a)(HCl test (Fillers)) |
- |
2000 |
|
- |
| 5.7 (a)(HCl test (Assessment of halogen test)) |
- |
5000 |
|
- |
| 5.7 (b)(pH test (Assessment of halogen test)) |
- |
2000 |
|
- |
| 5.7 (c)(Conductivity test (Assessment of halogen test)) |
- |
3000 |
|
- |
| 5.7 (d)(Presence of fluorine test (Assessment of halogen test)) |
- |
3000 |
|
- |
| 5.7 (e)(Fluorine content test (Assessment of halogen test)) |
- |
3000 |
|
- |
| Table 2 ,( Clause 11.4, 12.4, 13.7 14.7 and 15.7 )(Insulation Resistance) |
- |
3000 |
|
- |
| "Table 2 ( Clause 11.4, 12.4, 13.7 14.7 and 15.7 )"(Conductor Resistance) |
- |
3000 |
|
- |
| Table 2 , Clause .5.13(Water immersion test (Effect of water on sheath) - TS Variation of Sheath) |
- |
3000 |
|
- |
| Table 2 , Clause 5.13(Water immersion test (Effect of water on sheath) - Elongation Variation of Sheath) |
- |
5000 |
|
- |
| "Table 2 ( Clause 11.4, 12.4, 13.7 14.7 and 15.7 )"(Hot Deformation) |
- |
2000 |
|
- |
| Table 2, III.a.ii(Annealing test (for Cu,
before stranding)) |
- |
2000 |
|
- |
| Table 2, II.a, b(Wrapping test before
stranding (for Al)) |
- |
5000 |
|
- |
| Cl.4.2.1 & Annex A(Insulation Resistance Constant at Rated Temperature (70°C)) |
- |
5000 |
|
- |
| Table 2, III a (i)(Conductor Resistance) |
- |
5000 |
|
- |
| Annex A(Hot Deformation) |
- |
5000 |
|
- |
| 6.1, Table 1(CORE IDENTIFICATION) |
- |
3000 |
|
- |
| 6.1(General Requirements) |
- |
3000 |
|
- |
| 6.1.1(Colour Combination Green Yellow) |
- |
2000 |
|
- |
| 12.1(Conductor) |
- |
2000 |
|
- |
| 12.2, Table 4(insulation) |
- |
2000 |
|
- |
| Table 4(Copper Purity test) |
- |
2000 |
|
- |
| 4.3.1 (e)(Fluorine content test (Fillers)) |
- |
2000 |
|
- |
| 4.3.1 (d)(Presence of fluorine test (Fillers)) |
- |
2000 |
|
- |
| 4.3.1 (c)(Conductivity test (Fillers)) |
- |
2000 |
|
- |
| 4.3.1 (b)(pH test (Fillers)) |
- |
2000 |
|
- |
| 4.3.1 (a)(HCl test (Fillers)) |
- |
2000 |
|
- |
| 5.7 (a)(HCl test (Assessment of halogen test)) |
- |
2000 |
|
- |
| 5.7 (b)(pH test (Assessment of halogen test)) |
- |
2000 |
|
- |
| 5.7 (c)(Conductivity test (Assessment of halogen test)) |
- |
2000 |
|
- |
| 5.7 (d)(Presence of fluorine test (Assessment of halogen test)) |
- |
2000 |
|
- |
| 5.7 (e)(Fluorine content test (Assessment of halogen test)) |
- |
2000 |
|
- |
| Table 2 ,( Clause 11.4, 12.4, 13.7 14.7 and 15.7 )(Insulation Resistance) |
- |
2000 |
|
- |
| "Table 2 ( Clause 11.4, 12.4, 13.7 14.7 and 15.7 )"(Conductor Resistance) |
- |
2000 |
|
- |
| Table 2 , Clause .5.13(Water immersion test (Effect of water on sheath) - TS Variation of Sheath) |
- |
2000 |
|
- |
| Table 2 , Clause 5.13(Water immersion test (Effect of water on sheath) - Elongation Variation of Sheath) |
- |
2000 |
|
- |
| "Table 2 ( Clause 11.4, 12.4, 13.7 14.7 and 15.7 )"(Hot Deformation) |
- |
2000 |
|
- |
| Table 2, III.a.ii(Annealing test (for Cu,
before stranding)) |
- |
2000 |
|
- |
| Table 2, II.a, b(Wrapping test before
stranding (for Al)) |
- |
2000 |
|
- |
| Cl.4.2.1 & Annex A(Insulation Resistance Constant at Rated Temperature (70°C)) |
- |
2000 |
|
- |
| Table 2, III a (i)(Conductor Resistance) |
- |
2000 |
|
- |
| Annex A(Hot Deformation) |
- |
2000 |
|
- |
| 6.1, Table 1(CORE IDENTIFICATION) |
- |
1000 |
|
- |
| 6.1(General Requirements) |
- |
1000 |
|
- |
| 6.1.1(Colour Combination Green Yellow) |
- |
1000 |
|
- |
| 12.1(Conductor) |
- |
1000 |
|
- |
| 12.2, Table 4(insulation) |
- |
1000 |
|
- |
| Table 4(Copper Purity test) |
- |
1000 |
|
- |
| 4.3.1 (e)(Fluorine content test (Fillers)) |
- |
1000 |
|
- |
| 4.3.1 (d)(Presence of fluorine test (Fillers)) |
- |
1000 |
|
- |
| 4.3.1 (c)(Conductivity test (Fillers)) |
- |
1000 |
|
- |
| 4.3.1 (b)(pH test (Fillers)) |
- |
1000 |
|
- |
| 4.3.1 (a)(HCl test (Fillers)) |
- |
1000 |
|
- |
| 5.7 (a)(HCl test (Assessment of halogen test)) |
- |
1000 |
|
- |
| 5.7 (b)(pH test (Assessment of halogen test)) |
- |
1000 |
|
- |
| 5.7 (c)(Conductivity test (Assessment of halogen test)) |
- |
1000 |
|
- |
| 5.7 (d)(Presence of fluorine test (Assessment of halogen test)) |
- |
1000 |
|
- |
| 5.7 (e)(Fluorine content test (Assessment of halogen test)) |
- |
1000 |
|
- |
| Table 2 ,( Clause 11.4, 12.4, 13.7 14.7 and 15.7 )(Insulation Resistance) |
- |
1000 |
|
- |
| "Table 2 ( Clause 11.4, 12.4, 13.7 14.7 and 15.7 )"(Conductor Resistance) |
- |
1000 |
|
- |
| Table 2 , Clause .5.13(Water immersion test (Effect of water on sheath) - TS Variation of Sheath) |
- |
1000 |
|
- |
| Table 2 , Clause 5.13(Water immersion test (Effect of water on sheath) - Elongation Variation of Sheath) |
- |
1000 |
|
- |
| "Table 2 ( Clause 11.4, 12.4, 13.7 14.7 and 15.7 )"(Hot Deformation) |
- |
1000 |
|
- |
| Table 2, III.a.ii(Annealing test (for Cu,
before stranding)) |
- |
1000 |
|
- |
| Table 2, II.a, b(Wrapping test before
stranding (for Al)) |
- |
1000 |
|
- |
| Cl.4.2.1 & Annex A(Insulation Resistance Constant at Rated Temperature (70°C)) |
- |
1000 |
|
- |
| Table 2, III a (i)(Conductor Resistance) |
- |
1000 |
|
- |
| Annex A(Hot Deformation) |
- |
1000 |
|
- |
|
- |
- included w.e.f 09-12-2025 |
| 4685 |
Arihant Analytical Laboratory Pvt. Ltd., Sonipat
| 9167906
| IS 9873 : Part 9 (2017) |
Safety of Toys Part 9 Certain Phthalates Esters in Toys and Children's Products |
All type |
3500.00 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 3.0(Vinyl in toys or childcare articles - a) Bis-(2-ethlyhexyl) Phthalates (DEHP), b) Di-Butyl phthalate (DBP), c) Benzyl butyl Phthalate (BBP) - IS 9873 Part 6) |
- |
500 |
|
- |
| 3.0(Vinyl in any part of the toy or childcare article that can be placed in mouth of a child under 4 years of age - a) Di-iso-Nonyl Phthalate (DINP), b) Di-iso-Decyl Phthalate (DIDP), c) Di-n-Octyl Phthalate (DNOP) - IS 9873 Part 6) |
- |
500 |
|
- |
| 3.0(Vinyl in toys or childcare articles - a) Bis-(2-ethlyhexyl) Phthalates (DEHP), b) Di-Butyl phthalate (DBP), c) Benzyl butyl Phthalate (BBP) - IS 9873 Part 6) |
- |
500 |
|
- |
| 3.0(Vinyl in any part of the toy or childcare article that can be placed in mouth of a child under 4 years of age - a) Di-iso-Nonyl Phthalate (DINP), b) Di-iso-Decyl Phthalate (DIDP), c) Di-n-Octyl Phthalate (DNOP) - IS 9873 Part 6) |
- |
500 |
|
- |
| 3.0(Vinyl in toys or childcare articles - a) Bis-(2-ethlyhexyl) Phthalates (DEHP), b) Di-Butyl phthalate (DBP), c) Benzyl butyl Phthalate (BBP) - IS 9873 Part 6) |
- |
500 |
|
- |
| 3.0(Vinyl in any part of the toy or childcare article that can be placed in mouth of a child under 4 years of age - a) Di-iso-Nonyl Phthalate (DINP), b) Di-iso-Decyl Phthalate (DIDP), c) Di-n-Octyl Phthalate (DNOP) - IS 9873 Part 6) |
- |
500 |
|
- |
| 3.0(Vinyl in toys or childcare articles - a) Bis-(2-ethlyhexyl) Phthalates (DEHP), b) Di-Butyl phthalate (DBP), c) Benzyl butyl Phthalate (BBP) - IS 9873 Part 6) |
- |
500 |
|
- |
| 3.0(Vinyl in any part of the toy or childcare article that can be placed in mouth of a child under 4 years of age - a) Di-iso-Nonyl Phthalate (DINP), b) Di-iso-Decyl Phthalate (DIDP), c) Di-n-Octyl Phthalate (DNOP) - IS 9873 Part 6) |
- |
500 |
|
- |
|
02 Jun, 2027 |
- Included w.e.f.12.09.2025 |
| 4686 |
EMC Testing and Compliance LLP, Gurugram
| 8141526
| IS 302 : Part 2 : Sec 30 (2007) |
Safety of household and similar electrical appliances: Part 2 particular requirements: Sec 30 room heaters (First Revision) |
- |
60000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl.6 (Classification) |
- |
500 |
|
- |
| Cl.6 (Classification) |
- |
500 |
|
- |
| Cl.7 & IS:302-1:2008(Marking and Instructions) |
- |
1000 |
|
- |
| Cl.7 & IS:302-1:2008(Marking and Instructions) |
- |
1000 |
|
- |
| Cl.7 & IS:302-1:2008(Marking and Instructions) |
- |
1000 |
|
- |
| Cl.7 & IS:302-1:2008(Marking and Instructions) |
- |
1000 |
|
- |
| Cl.7 & IS:302-1:2008(Marking and Instructions) |
- |
1000 |
|
- |
| Cl.7 & IS:302-1:2008(Marking and Instructions) |
- |
1000 |
|
- |
| Cl.7 & IS:302-1:2008(Marking and Instructions) |
- |
1000 |
|
- |
| Cl.7 & IS:302-1:2008(Marking and Instructions) |
- |
1000 |
|
- |
| Cl.7 & IS:302-1:2008(Marking and Instructions) |
- |
1000 |
|
- |
| Cl.7(Marking and Instructions) |
- |
1000 |
|
- |
| Cl.7(Marking and Instructions) |
- |
1000 |
|
- |
| Cl.7(Marking and Instructions) |
- |
1000 |
|
- |
| Cl.7.3(Marking and Instructions) |
- |
1000 |
|
- |
| Cl.7.3(Marking and Instructions) |
- |
1000 |
|
- |
| Cl.7.3(Marking and Instructions) |
- |
1000 |
|
- |
| Cl.7.4(Marking and Instructions) |
- |
1000 |
|
- |
| Cl.7.5(Marking and Instructions) |
- |
1000 |
|
- |
| Cl.7.6 & IS:302-1:2008(Marking and Instructions) |
- |
1000 |
|
- |
| Cl.7.8 of IS :302-1:2008(Marking and Instructions) |
- |
1000 |
|
- |
| Cl.7.9 of IS :302-1:2008(Marking and Instructions) |
- |
1000 |
|
- |
| Cl.7.10 of IS :302-1:2008(Marking and Instructions) |
- |
1000 |
|
- |
| Cl.7.11 of IS :302-1:2008(Marking and Instructions) |
- |
1000 |
|
- |
| Cl.7.12 & IS:302-1:2008(Marking and Instructions) |
- |
1000 |
|
- |
| Cl.7.12 & IS:302-1:2008(Marking and Instructions) |
- |
1000 |
|
- |
| Cl.7.12 & IS:302-1:2008(Marking and Instructions) |
- |
1000 |
|
- |
| Cl.7.12 & IS:302-1:2008(Marking and Instructions) |
- |
1000 |
|
- |
| Cl.7.12 & IS:302-1:2008(Marking and Instructions) |
- |
1000 |
|
- |
| Cl.7.12 & IS:302-1:2008(Marking and Instructions) |
- |
1000 |
|
- |
| Cl.7.12 & IS:302-1:2008(Marking and Instructions) |
- |
1000 |
|
- |
| Cl.7.12 & IS:302-1:2008(Marking and Instructions) |
- |
1000 |
|
- |
| Cl.7.12 & IS:302-1:2008(Marking and Instructions) |
- |
1000 |
|
- |
| Cl.7.12 & IS:302-1:2008(Marking and Instructions) |
- |
1000 |
|
- |
| Cl.7.12 & IS:302-1:2008(Marking and Instructions) |
- |
1000 |
|
- |
| Cl.7.12 & IS:302-1:2008(Marking and Instructions) |
- |
1000 |
|
- |
| Cl.7.12.1 & IS:302-1:2008(Marking and Instructions) |
- |
1000 |
|
- |
| Cl.7.12.1 & IS:302-1:2008(Marking and Instructions) |
- |
1000 |
|
- |
| Cl.7.12.1 & IS:302-1:2008(Marking and Instructions) |
- |
1000 |
|
- |
| Cl.7.12.1 & IS:302-1:2008(Marking and Instructions) |
- |
1000 |
|
- |
| Cl.7.12.1 & IS:302-1:2008(Marking and Instructions) |
- |
1000 |
|
- |
| Cl.7.12.1 & IS:302-1:2008(Marking and Instructions) |
- |
1000 |
|
- |
| Cl.7.12.1 & IS:302-1:2008(Marking and Instructions) |
- |
1000 |
|
- |
| Cl.7.12.1 & IS:302-1:2008(Marking and Instructions) |
- |
1000 |
|
- |
| Cl.7.12.1 & IS:302-1:2008(Marking and Instructions) |
- |
1000 |
|
- |
| Cl.7.12.1 & IS:302-1:2008(Marking and Instructions) |
- |
1000 |
|
- |
| Cl.7.12.1 & IS:302-1:2009(Marking and Instructions) |
- |
1000 |
|
- |
| Cl.7.13 of IS 302-1:2008(Marking and Instructions) |
- |
1000 |
|
- |
| Cl.7.14 of IS302-1:2008(Marking and Instructions) |
- |
1000 |
|
- |
| Cl.7.14(Marking and Instructions) |
- |
1000 |
|
- |
| Cl.7.14(Marking and Instructions) |
- |
1000 |
|
- |
| Cl.7.15 of IS 302-1:2008(Marking and Instructions) |
- |
1000 |
|
- |
| Cl.7.15 of IS 302-1:2008(Marking and Instructions) |
- |
1000 |
|
- |
| Cl.7.15 of IS 302-1:2008(Marking and Instructions) |
- |
1000 |
|
- |
| Cl.7.15 of IS 302-1:2008(Marking and Instructions) |
- |
1000 |
|
- |
| Cl.7.101(Marking and Instructions) |
- |
1000 |
|
- |
| Cl.8 & IS:302-1:2008(Protection Against Access to Live Parts) |
- |
2000 |
|
- |
| Cl.10 & IS:302-1:2008(Power Input and Current) |
- |
2000 |
|
- |
| Cl.11 & IS:302-1:2008(Heating) |
- |
5000 |
|
- |
| Cl.11 & IS:302-1:2008(Heating) |
- |
5000 |
|
- |
| Cl.11 & IS:302-1:2008(Heating) |
- |
5000 |
|
- |
| Cl.11 & IS:302-1:2008(Heating) |
- |
5000 |
|
- |
| Cl.11 & IS:302-1:2008(Heating) |
- |
5000 |
|
- |
| Cl.11 & IS:302-1:2008(Heating) |
- |
5000 |
|
- |
| Cl.11 & IS:302-1:2008(Heating) |
- |
5000 |
|
- |
| Cl.11 & IS:302-1:2008(Heating) |
- |
5000 |
|
- |
| Cl.11 & IS:302-1:2008(Heating) |
- |
5000 |
|
- |
| Cl.11 & IS:302-1:2008(Heating) |
- |
5000 |
|
- |
| Cl.11 & IS:302-1:2008(Heating) |
- |
5000 |
|
- |
| Cl.11 & IS:302-1:2008(Heating) |
- |
5000 |
|
- |
| Cl.11 & IS:302-1:2008(Heating) |
- |
5000 |
|
- |
| Cl.11 & IS:302-1:2008(Heating) |
- |
5000 |
|
- |
| Cl.11 & IS:302-1:2008(Heating) |
- |
5000 |
|
- |
| Cl.11 & IS:302-1:2008(Heating) |
- |
5000 |
|
- |
| Cl.11.8(Heating) |
- |
5000 |
|
- |
| Cl.11.8(Heating) |
- |
5000 |
|
- |
| Cl.11.8(Heating) |
- |
5000 |
|
- |
| Cl.13 & IS:302-1:2008(Leakage Current & Electric Strength at operating temp. ) |
- |
5000 |
|
- |
| Cl.13 & IS:302-1:2008(Leakage Current & Electric Strength at operating temp. ) |
- |
5000 |
|
- |
| Cl.14 & IS:302-1:2008(Transient Over Voltages) |
- |
10000 |
|
- |
| Cl.15 & IS: 302-1:2008(Moisture Resistance
) |
- |
5000 |
|
- |
| Cl.15.3 of IS 302-1:200(Moisture Resistance
) |
- |
5000 |
|
- |
| Cl.16 & IS:302-1:2008(Leakage Current & Electric Strength ) |
- |
5000 |
|
- |
| Cl.16 & IS:302-1:2008(Leakage Current & Electric Strength ) |
- |
5000 |
|
- |
| Cl.17 & IS:302-1:2008(Over load Protection of Transformers and Associated Circuits ) |
- |
5000 |
|
- |
| Cl.18 (Endurance. ) |
- |
0 |
|
- |
| Cl.19 & IS:302-1:2008(Abnormal Operation.) |
- |
2000 |
|
- |
| Cl.19 & IS:302-1:2008(Abnormal Operation.) |
- |
2000 |
|
- |
| Cl.19 & IS:302-1:2008(Abnormal Operation.) |
- |
2000 |
|
- |
| Cl.19 & IS:302-1:2008(Abnormal Operation.) |
- |
2000 |
|
- |
| Cl.19.101(Abnormal Operation.) |
- |
2000 |
|
- |
| Cl.19.102(Abnormal Operation.) |
- |
2000 |
|
- |
| Cl.19.103(Abnormal Operation.) |
- |
2000 |
|
- |
| Cl.19.104(Abnormal Operation.) |
- |
2000 |
|
- |
| Cl.19.105(Abnormal Operation.) |
- |
2000 |
|
- |
| Cl.19.106(Abnormal Operation.) |
- |
2000 |
|
- |
| Table 8 of IS 302-1:2008(Abnormal Operation.) |
- |
2000 |
|
- |
| Cl.19.107(Abnormal Operation.) |
- |
2000 |
|
- |
| Cl.19.108(Abnormal Operation.) |
- |
2000 |
|
- |
| Cl.19.109(Abnormal Operation.) |
- |
2000 |
|
- |
| Cl.19.110(Abnormal Operation.) |
- |
2000 |
|
- |
| Cl.19.111(Abnormal Operation.) |
- |
2000 |
|
- |
| Cl.19.112(Abnormal Operation.) |
- |
2000 |
|
- |
| Cl.19.113(Abnormal Operation.) |
- |
2000 |
|
- |
| Cl.19.114(Abnormal Operation.) |
- |
2000 |
|
- |
| Cl.20 & IS:302-1:2008(Stability & Mechanical Hazards) |
- |
2000 |
|
- |
| Cl.21 & IS:302-1:2008)(Mechanical Strength.) |
- |
2000 |
|
- |
| Cl.21.2 of IS 302-1:2008(Mechanical Strength.) |
- |
2000 |
|
- |
| Cl.21.101 (Mechanical Strength.) |
- |
2000 |
|
- |
| Cl.21.102(Mechanical Strength.) |
- |
2000 |
|
- |
| Cl.21.103(Mechanical Strength.) |
- |
2000 |
|
- |
| Cl.22.1 of IS 302-1:2008(Construction) |
- |
2000 |
|
- |
| Cl.22.5 of IS 302-1:2008(Construction) |
- |
2000 |
|
- |
| Cl.22.6 of IS 302-1:2008(Construction) |
- |
2000 |
|
- |
| Cl.22.7 of IS 302-1:2008(Construction) |
- |
2000 |
|
- |
| Cl.22.8 of IS 302-1:2008(Construction) |
- |
2000 |
|
- |
| Cl.22.9 of IS 302-1:2008(Construction) |
- |
2000 |
|
- |
| Cl.22.11(Construction) |
- |
2000 |
|
- |
| Cl.22.12 of IS 302-1:2008(Construction) |
- |
2000 |
|
- |
| Cl.22.13 of IS 302-1:2008(Construction) |
- |
2000 |
|
- |
| Cl.22.14 of IS 302-1:2008(Construction) |
- |
2000 |
|
- |
| Cl.22.15 of IS 302-1:2008(Construction) |
- |
2000 |
|
- |
| Cl.22.18 of IS 302-1:2008(Construction) |
- |
2000 |
|
- |
| Cl.22.20 of IS 302-1:2008(Construction) |
- |
2000 |
|
- |
| Cl.22.21 of IS 302-1:2008(Construction) |
- |
2000 |
|
- |
| Cl.23 & IS:302-1:2008(Internal Wiring
) |
- |
2000 |
|
- |
| Cl.23.4 & Cl.29 of 302-1:2008(Internal Wiring
) |
- |
2000 |
|
- |
| Cl.23.5 of 302-1:2008(Internal Wiring
) |
- |
2000 |
|
- |
| Cl.23.7 of 302-1:2008(Internal Wiring
) |
- |
2000 |
|
- |
| C.23.7 of 302-1:2008(Internal Wiring
) |
- |
2000 |
|
- |
| Cl.24.1 of 302-1:2008(Component) |
- |
2000 |
|
- |
| Cl.24.1 of 302-1:2008(Component) |
- |
2000 |
|
- |
| Cl.24.1.3 (Component) |
- |
2000 |
|
- |
| Cl.24.1.3 (Component) |
- |
2000 |
|
- |
| Cl.24.1.3 (Component) |
- |
2000 |
|
- |
| Cl.24.1.3 (Component) |
- |
2000 |
|
- |
| C.24.1.4(Component) |
- |
2000 |
|
- |
| C.24.2 of 302-1:2008(Component) |
- |
2000 |
|
- |
| Cl.24.10(Component) |
- |
2000 |
|
- |
| Cl.25.1 of 302-1:2008(Supply Connection and External Flexible Cords ) |
- |
2000 |
|
- |
| Cl. 25.2 of IS 3021:2008(Supply Connection and External Flexible Cords ) |
- |
2000 |
|
- |
| Cl. 25.3 of IS 302-1:2008(Supply Connection and External Flexible Cords ) |
- |
2000 |
|
- |
| Cl. 25.4 of IS 302-1:2008(Supply Connection and External Flexible Cords ) |
- |
2000 |
|
- |
| Cl.25.5 of 302-1:2008(Supply Connection and External Flexible Cords ) |
- |
2000 |
|
- |
| Cl.25.6 of 302-1:2008(Supply Connection and External Flexible Cords ) |
- |
2000 |
|
- |
| Cl.25.7.(Supply Connection and External Flexible Cords ) |
- |
2000 |
|
- |
| Cl.25.8(Supply Connection and External Flexible Cords ) |
- |
2000 |
|
- |
| Cl. 25.9(Supply Connection and External Flexible Cords ) |
- |
2000 |
|
- |
| Cl.25.10 of 302-1:2008(Supply Connection and External Flexible Cords ) |
- |
2000 |
|
- |
| Cl. 25.11(Supply Connection and External Flexible Cords ) |
- |
2000 |
|
- |
| Cl. 25.12(Supply Connection and External Flexible Cords ) |
- |
2000 |
|
- |
| Cl. 25.13(Supply Connection and External Flexible Cords ) |
- |
2000 |
|
- |
| Cl.25.14 of IS 302-1:2008(Supply Connection and External Flexible Cords ) |
- |
2000 |
|
- |
| Cl.25.15 of IS 302-1:2008(Supply Connection and External Flexible Cords ) |
- |
2000 |
|
- |
| Cl.25.15 of IS 302-1:2008(Supply Connection and External Flexible Cords ) |
- |
2000 |
|
- |
| Cl.25.17 of IS 302-1:2008(Supply Connection and External Flexible Cords ) |
- |
2000 |
|
- |
| Cl.25.18(Supply Connection and External Flexible Cords ) |
- |
2000 |
|
- |
| Cl.25.20(Supply Connection and External Flexible Cords ) |
- |
2000 |
|
- |
| Cl.26.1 of IS 302-1:2008(Terminal for External Conductors
) |
- |
2000 |
|
- |
| Cl.26.10 of IS 302-1:2008(Terminal for External Conductors
) |
- |
2000 |
|
- |
| Cl.26.11 of IS 302-1:2008(Terminal for External Conductors
) |
- |
2000 |
|
- |
| Cl.27.1 of 302-1:2008(Provision for Earthing.) |
- |
2000 |
|
- |
| Cl.27.5 of 302-1:2008(Provision for Earthing.) |
- |
2000 |
|
- |
| Cl.28 of 302-1:2008(Screws and Connections.) |
- |
2000 |
|
- |
| Cl.29 & IS:302-1:2008(Clearances, Creepage Distances and Solid Insulation) |
- |
2000 |
|
- |
| Cl.29 & IS:302-1:2008(Clearances, Creepage Distances and Solid Insulation) |
- |
2000 |
|
- |
| Cl.30 & IS:302-1:2008(Resistance to Heat and Fire) |
- |
5000 |
|
- |
| Cl.30.2.2 of 302-1:2008(Resistance to Heat and Fire) |
- |
5000 |
|
- |
| Cl.31 & IS:302-1:2008(Resistance to Rusting.) |
- |
2000 |
|
- |
| Cl.32 & IS:302-1:2008(Radition,Toxicity and similar Hazards.) |
- |
2000 |
|
- |
| Cl.31 of IS:302-1:2008(Resistance to Rusting.) |
- |
2000 |
|
- |
| Cl.30.2 of 302-1:2008(Resistance to Heat and Fire : Resistance to fire) |
- |
5000 |
|
- |
| Cl.30.1 of IS:302-1:2008(Resistance to Heat and Fire: Resistance to heat. ) |
- |
5000 |
|
- |
| Cl.29.2 of IS:302-1:2008(Clearances, Creepage Distances and Solid Insulation : Creepage Distance) |
- |
2000 |
|
- |
| Cl.29.1 of IS:302-1:2008(Clearances, Creepage Distances and Solid Insulation : Clearance ) |
- |
2000 |
|
- |
| Cl.28 of 302-1:2008(Screws and Connections.) |
- |
2000 |
|
- |
| Cl.27.5 of 302-1:2008(Provision for Earthing : ECR) |
- |
2000 |
|
- |
| Cl.27.1 of 302-1:2008(Provision for Earthing ) |
- |
2000 |
|
- |
| Cl.26 of IS 302-1:2008(Terminal for External Conductors
) |
- |
2000 |
|
- |
| Cl.25.20 of 302-1:2008(Supply Connection and External Flexible Cords : Additional insulation ) |
- |
2000 |
|
- |
| Cl.25.18 of 302-1:2008(Supply Connection and External Flexible Cords : Arrangement of cord anchorages ) |
- |
2000 |
|
- |
| Cl.25.15 of IS 302-1:2008(Supply Connection and External Flexible Cords : Cord grip test - displacement) |
- |
2000 |
|
- |
| Cl.25.15 of IS 302-1:2008(Supply Connection and External Flexible Cords : Cord grip test - strain at terminals ) |
- |
2000 |
|
- |
| Cl. 25.13 of 302-1:2008(Supply Connection and External Flexible Cords : Inlet opening of supply cords ) |
- |
2000 |
|
- |
| Cl. 25.12 of 302-1:2008(Supply Connection and External Flexible Cords : Moulding of cords ) |
- |
2000 |
|
- |
| Cl.25.10 of 302-1:2008(Supply Connection and External Flexible Cords : Colour of earthing wire ) |
- |
2000 |
|
- |
| Cl. 25.9 of 302-1:2008(Supply Connection and External Flexible Cords : Contact with sharp edge ) |
- |
2000 |
|
- |
| Cl.25.8 of 302-1:2008(Supply Connection and External Flexible Cords : Resistance of supply wires ) |
- |
2000 |
|
- |
| Cl.25.7 of IS:302-2-30:2007(Supply Connection and External Flexible Cords : Supply cords material ) |
- |
2000 |
|
- |
| Cl.25.5 of 302-1:2008(Supply Connection and External Flexible Cords : Type of attachments ) |
- |
2000 |
|
- |
| Cl.25.1 of 302-1:2008(Supply Connection and External Flexible Cords : Means of connection ) |
- |
2000 |
|
- |
| Cl.24 of IS:302-2-30:2007(Component) |
- |
2000 |
|
- |
| Cl.23.7 of 302-1:2008(Internal Wiring : Colour of earting conductor
) |
- |
2000 |
|
- |
| Cl.23 of IS:302-1:2008(Internal Wiring
) |
- |
2000 |
|
- |
| Cl.22.106 of IS:302-2-30:2007(Construction : Checking of thermostats, timers or similar means for visibl glowing radiant heaters) |
- |
2000 |
|
- |
| Cl.22.106 of IS:302-2-30:2007(Construction : Checking of openings on the underside) |
- |
2000 |
|
- |
| Cl.22.102 & Cl 22.103 of IS:302-2-30:2007(Construction : Fireguard ) |
- |
2000 |
|
- |
| Cl.22.101 of IS:302-2-30:2007(Construction : Prevention to contact with heating element) |
- |
2000 |
|
- |
| Cl.22.24 of IS:302-2-30:2007(Construction : test of bare heating element) |
- |
2000 |
|
- |
| Cl.22.18 of IS 302-1:2008(Construction : Resistance to corrosion ) |
- |
2000 |
|
- |
| Cl.22.15 of IS 302-1:2008(Construction : Storage hooks for flexible cords) |
- |
2000 |
|
- |
| Cl.22.14 of IS 302-1:2008(Construction : ragged and sharp edges) |
- |
2000 |
|
- |
| Cl.22.13 of IS 302-1:2008(Construction : Position of handles ) |
- |
2000 |
|
- |
| Cl.22.12 of IS 302-1:2008(Construction : Fixing of Handle, knobs,grips,lever and similer parts ) |
- |
2000 |
|
- |
| Cl.22.11 of IS 302-1:2008(Construction : Fixing of non detachable parts ) |
- |
2000 |
|
- |
| Cl.22.7 of IS:302-2-30:2007(Construction : Pressure test of oil heater ) |
- |
2000 |
|
- |
| Cl.21.101 of IS:302-2-30:2007(Mechanical Strength : fire gaurd deformation test ) |
- |
2000 |
|
- |
| Cl.21.2 of IS 302-1:2008(Mechanical Strength : Pentration by sharp implementation ) |
- |
2000 |
|
- |
| Cl.21.1 of IS:302-1:2008)(Mechanical Strength : Rough handling ) |
- |
2000 |
|
- |
| Cl.20 of IS:302-2-30:2007(Stability of Mechanical Hazards) |
- |
2000 |
|
- |
| Cl.19.114 of IS:302-2-30:2007(Abnormal Operation : the temp. of the surface of the container for oil heaters ) |
- |
2000 |
|
- |
| Cl.19.112 of IS:302-2-30:2007(Abnormal Operation : Ignition of bleached cotton gauge) |
- |
2000 |
|
- |
| Cl.19.111 of IS:302-2-30:2007(Abnormal Operation : Ignition of flannelette for Visibly glowing heaters) |
- |
2000 |
|
- |
| Cl.19.110 of IS:302-2-30:2007(Abnormal Operation : operation against wall for visibly glowing radiant heaters ) |
- |
2000 |
|
- |
| Cl.19.109 of IS:302-2-30:2007(Abnormal Operation : operation against wall for fan heater ) |
- |
2000 |
|
- |
| Cl.19.106 of IS:302-2-30:2007(Abnormal Operation : Locked rotor of fan hetear ) |
- |
2000 |
|
- |
| Cl.19.103 , Cl 19.104 of IS:302-2-30:2007(Abnormal Operation : Operation after Covering by cotton) |
- |
2000 |
|
- |
| Cl.19 of IS:302-2-30:2007(Abnormal Operation : High Voltage ) |
- |
2000 |
|
- |
| Cl.19 of IS:302-2-30:2007(Abnormal Operation : temp rise of supply cord ) |
- |
2000 |
|
- |
| Cl.19 of IS:302-2-30:2007(Abnormal Operation : Temp rise of test corner ) |
- |
2000 |
|
- |
| Cl.19 of IS:302-1:2008(Abnormal Operation : Emission of molten or poisonous or ignitable gas) |
- |
2000 |
|
- |
| Cl.16 of IS:302-1:2008(Leakage current and Electric strength (After humidity): Electric Strentgh ) |
- |
2000 |
|
- |
| Cl.16 of IS:302-1:2008(Leakage current and Electric strength (After humidity): Leakage current ) |
- |
2000 |
|
- |
| Cl.15 of IS 302-1:2008(Moisture Resistance
) |
- |
2000 |
|
- |
| Cl.14 of IS:302-1:2008(Transient Over Voltages) |
- |
2000 |
|
- |
| Cl.13 of IS:302-1:2008(Leakage Current of Electric Strength at operating temp. ) |
- |
2000 |
|
- |
| Cl.13 of IS:302-1:2008(Leakage Current of Electric Strength at operating temp. ) |
- |
2000 |
|
- |
| Cl.11 of IS:302-2:30: 2007(Heating : Room temperature) |
- |
2000 |
|
- |
| Cl.11.8 of IS:302-2:30: 2007(Heating : For liquid filled radiators the temp. rise of the outer surface of the liquid container) |
- |
2000 |
|
- |
| Cl.11 of IS:302-2:30: 2007(Heating : Temperature rise in winding) |
- |
2000 |
|
- |
| Cl.11 of IS:302-2:30: 2007(Heating : Air-outlet grills) |
- |
2000 |
|
- |
| Cl.11 of IS:302-2:30: 2007(Heating : Surfaces of handles, knobs, grips and similar parts) |
- |
2000 |
|
- |
| Cl.11 of IS:302-2:30: 2007(Heating : Wooden supports, walls, ceiling and floor of the test corner) |
- |
2000 |
|
- |
| Cl.11 of IS:302-2:30: 2007(Heating : PVC Insulation ) |
- |
2000 |
|
- |
| Cl.10 of IS:302-1:2008(Power Input and Current) |
- |
2000 |
|
- |
| Cl.8 of IS:302-1:2008(Protection Against Access to Live Parts) |
- |
2000 |
|
- |
| Cl.7.101 of IS:302-2:30: 2007(Marking and Instructions : standard mark. ) |
- |
2000 |
|
- |
| Cl.7.15 of IS 302-1:2008(Marking and Instructions : Visibility of marking concerning covering) |
- |
2000 |
|
- |
| Cl.7.15 of IS 302-1:2008(Marking and Instructions : discernibility from the out side ) |
- |
2000 |
|
- |
| Cl.7.14 of IS:302-2:30: 2007(Marking and Instructions : Height of “Do not cover”) |
- |
2000 |
|
- |
| Cl.7.14 of IS:302-2:30: 2007(Marking and Instructions : height of symbol) |
- |
2000 |
|
- |
| Cl.7.14 of IS302-1:2008(Marking and Instructions : Legibility and durability ) |
- |
2000 |
|
- |
| Cl.7.13 of IS 302-1:2008(Marking and Instructions : Languge of instruction and texts ) |
- |
2000 |
|
- |
| Cl.7.11 of IS :302-1:2008(Marking and Instructions : Controls ) |
- |
2000 |
|
- |
| Cl.7.9 of IS :302-1:2008(Marking and Instructions : switches ) |
- |
2000 |
|
- |
| Cl.7.8 of IS :302-1:2008(Marking and Instructions : terminals ) |
- |
2000 |
|
- |
| Cl.7.6 of IS:302-1:2008(Marking and Instructions : Symbols ) |
- |
2000 |
|
- |
| Cl.7.5 of IS:302-1:2008(Marking and Instructions : upper of lower limit of the rated power input ) |
- |
2000 |
|
- |
| Cl 7.1 & Cl.7.6 of IS:302-2:30: 2007(Marking and Instructions : Do not cover ) |
- |
2000 |
|
- |
| Cl.7.1 of IS:302-1:2008(Marking and Instructions : Country of manufacture ) |
- |
2000 |
|
- |
| Cl.7.1 of IS:302-1:2008(Marking and Instructions : Symbol for Class-II ) |
- |
2000 |
|
- |
| Cl.7.1 of IS:302-1:2008(Marking and Instructions : Model or type ) |
- |
2000 |
|
- |
| Cl.7.1 of IS:302-1:2008(Marking and Instructions : Name , trade-mark or identification mark of the manufacturer ) |
- |
2000 |
|
- |
| Cl.7.1 of IS:302-1:2008(Marking and Instructions : rated power input ) |
- |
2000 |
|
- |
| Cl.7.1 of IS:302-1:2008(Marking and Instructions : Nature of supply ) |
- |
2000 |
|
- |
| Cl.7.1 of IS:302-1:2008(Marking and Instructions : Rated Voltage ) |
- |
2000 |
|
- |
|
19 Jul, 2027 |
- Included w.e.f 26.06.2025 Exclusion: Cl 19.11.4.1-19.11.4.7(EMI/EMC) |
| 4687 |
Arihant Analytical Laboratory Pvt. Ltd., Sonipat
| 9167906
| IS 9873 : Part 3 (2017) |
Safety of toys: Part 3 migration of certain elements (Second Revision) |
All |
3000.00 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4.1 - Table 1(Antimony (Sb) - Cl 7,8,9 of IS 9873-3 : 2017 and
ISO 8124-3 : 2010) |
- |
500 |
|
- |
| 4.1 - Table 1(Arsenic (As) - Cl 7,8,9 of IS 9873-3 : 2017 and
ISO 8124-3 : 2010) |
- |
500 |
|
- |
| 4.1 - Table 1(Barium (Ba) - Cl 7,8,9 of IS 9873-3 : 2017 and
ISO 8124-3 : 2010) |
- |
500 |
|
- |
| 4.1 - Table 1(Cadmium (Cd) - Cl 7,8,9 of IS 9873-3 : 2017 and
ISO 8124-3 : 2010) |
- |
500 |
|
- |
| 4.1 - Table 1(Chromium (Cr) - Cl 7,8,9 of IS 9873-3 : 2017 and
ISO 8124-3 : 2010) |
- |
500 |
|
- |
| 4.1 - Table 1(Lead (Pb) - Cl 7,8,9 of IS 9873-3 : 2017 and
ISO 8124-3 : 2010) |
- |
500 |
|
- |
| 4.1 - Table 1(Mercury (Hg) - Cl 7,8,9 of IS 9873-3 : 2017 and
ISO 8124-3 : 2010) |
- |
500 |
|
- |
| 4.1 - Table 1(Selenium (Se) - Cl 7,8,9 of IS 9873-3 : 2017 and
ISO 8124-3 : 2010) |
- |
500 |
|
- |
| 4.1 - Table 1(Antimony (Sb) - Cl 7,8,9 of IS 9873-3 : 2017 and
ISO 8124-3 : 2010) |
- |
500 |
|
- |
| 4.1 - Table 1(Arsenic (As) - Cl 7,8,9 of IS 9873-3 : 2017 and
ISO 8124-3 : 2010) |
- |
500 |
|
- |
| 4.1 - Table 1(Barium (Ba) - Cl 7,8,9 of IS 9873-3 : 2017 and
ISO 8124-3 : 2010) |
- |
500 |
|
- |
| 4.1 - Table 1(Cadmium (Cd) - Cl 7,8,9 of IS 9873-3 : 2017 and
ISO 8124-3 : 2010) |
- |
500 |
|
- |
| 4.1 - Table 1(Chromium (Cr) - Cl 7,8,9 of IS 9873-3 : 2017 and
ISO 8124-3 : 2010) |
- |
500 |
|
- |
| 4.1 - Table 1(Lead (Pb) - Cl 7,8,9 of IS 9873-3 : 2017 and
ISO 8124-3 : 2010) |
- |
500 |
|
- |
| 4.1 - Table 1(Mercury (Hg) - Cl 7,8,9 of IS 9873-3 : 2017 and
ISO 8124-3 : 2010) |
- |
500 |
|
- |
| 4.1 - Table 1(Selenium (Se) - Cl 7,8,9 of IS 9873-3 : 2017 and
ISO 8124-3 : 2010) |
- |
500 |
|
- |
|
02 Jun, 2027 |
- Included w.e.f 14.08.2025 |
| 4688 |
ALPHA TEST HOUSE PVT LTD, BAHADURGARH
| 8185306
| IS 16046 : Part 2 (2018) |
Secondary Cells and Batteries Containing Alkaline or Other Non-Acid Electrolytes ” Safety Requirements for Portable Sealed Secondary Cells and for Batteries Made from Them for Use in Portable Applications Part 2 Lithium Systems ( Second Revision ) |
All |
70000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4(Parameter Measurement Tolerances) |
- |
70000 |
|
- |
| 5(General Safety Considerations) |
- |
70000 |
|
- |
| 5.1(General) |
- |
70000 |
|
- |
| 5.2(Insulation and Wiring) |
- |
70000 |
|
- |
| 5.3(Venting) |
- |
70000 |
|
- |
| 5.4(Temperature, Voltage and Current Management) |
- |
70000 |
|
- |
| 5.5(Terminal Contacts) |
- |
70000 |
|
- |
| 5.6(Assembly of Cells into batteries) |
- |
70000 |
|
- |
| 5.7(Quality Plan) |
- |
70000 |
|
- |
| 5.8(Battery Safety Components) |
- |
70000 |
|
- |
| 6(Type Test and Sample Size) |
- |
70000 |
|
- |
| 7(Specific requirements and tests) |
- |
70000 |
|
- |
| 7.1(Charging procedure for test purposes) |
- |
70000 |
|
- |
| 7.2(Intended Use) |
- |
70000 |
|
- |
| 7.3(Reasonably foreseeable misuse) |
- |
70000 |
|
- |
| 8(Information for safety) |
- |
70000 |
|
- |
| 8.1(General) |
- |
70000 |
|
- |
| 8.2(Small Cell and battery safety information) |
- |
70000 |
|
- |
| 9(Marking) |
- |
70000 |
|
- |
| 9.1(Cell Marking) |
- |
70000 |
|
- |
| 9.2(Battery Marking) |
- |
70000 |
|
- |
| 9.3(Caution for ingestion of small cells and batteries) |
- |
70000 |
|
- |
| 9.4(Other information) |
- |
70000 |
|
- |
| 10(Packaging) |
- |
70000 |
|
- |
|
08 May, 2028 |
- Included w.e.f 20.06.2025
Exclusion : Clause 7.3.1 of IS 16047: Part 3 |
| 4689 |
IEC TEST LABS LLP
| 8165726
| IS 398 : Part 6 (2021) |
Aluminium Conductors For Overhead Transmission Purposes Part 6: High conductivity aluminium alloy stranded conductors |
- |
150000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 16.2(Visual Examination) |
- |
2000 |
|
- |
| 16.3, Table 4(Measurement of Lay Ratio / Direction of Lay) |
- |
2000 |
|
- |
| 16.3, Table 4(Measurement of Lay Ratio / Direction of Lay) |
- |
2000 |
|
- |
| 16.3, Table 4(Measurement of Lay Ratio / Direction of Lay) |
- |
2000 |
|
- |
| 16.3, Table 4(Measurement of Lay Ratio / Direction of Lay) |
- |
2000 |
|
- |
| 16.4, Table 2(Measurement of Diameter of Individual Aluminium Alloy Wires) |
- |
2000 |
|
- |
| 16.5, Table 2(Breaking Load Test - before stranding) |
- |
2000 |
|
- |
| 16.5, Table 2(Breaking Load Test - after stranding) |
- |
3000 |
|
- |
| 16.6, Table 1(Elongation Test - before stranding) |
- |
2000 |
|
- |
| 16.6, Table 1(Elongation Test - after stranding) |
- |
3000 |
|
- |
| 16.7, Table 2(Resistivity Test) |
- |
5000 |
|
- |
| 16.8(Wrapping Test) |
- |
2000 |
|
- |
| 11(Stranding) |
- |
2000 |
|
- |
| 8(Freedom from defects) |
- |
2000 |
|
- |
| 16.9, Table 3(Ultimate Tensile Strength on Stranded Conductor) |
- |
30000 |
|
- |
| 16.10, Table 3(d.c. Resistance Test on Stranded Conductor) |
- |
5000 |
|
- |
| 16.11(Stress-strain Test) |
- |
100000 |
|
- |
| 16.2(Visual Examination) |
- |
2000 |
|
- |
| 16.3, Table 4(Measurement of Lay Ratio / Direction of Lay) |
- |
2000 |
|
- |
| 16.3, Table 4(Measurement of Lay Ratio / Direction of Lay) |
- |
2000 |
|
- |
| 16.3, Table 4(Measurement of Lay Ratio / Direction of Lay) |
- |
2000 |
|
- |
| 16.3, Table 4(Measurement of Lay Ratio / Direction of Lay) |
- |
2000 |
|
- |
| 16.4, Table 2(Measurement of Diameter of Individual Aluminium Alloy Wires) |
- |
2000 |
|
- |
| 16.5, Table 2(Breaking Load Test - before stranding) |
- |
3000 |
|
- |
| 16.5, Table 2(Breaking Load Test - after stranding) |
- |
3000 |
|
- |
| 16.6, Table 1(Elongation Test - before stranding) |
- |
3000 |
|
- |
| 16.6, Table 1(Elongation Test - after stranding) |
- |
3000 |
|
- |
| 16.7, Table 2(Resistivity Test) |
- |
5000 |
|
- |
| 16.8(Wrapping Test) |
- |
3000 |
|
- |
| 11(Stranding) |
- |
2000 |
|
- |
| 8(Freedom from defects) |
- |
2000 |
|
- |
| 16.9, Table 3(Ultimate Tensile Strength on Stranded Conductor) |
- |
30000 |
|
- |
| 16.10, Table 3(d.c. Resistance Test on Stranded Conductor) |
- |
5000 |
|
- |
| 16.11(Stress-strain Test) |
- |
100000 |
|
- |
|
07 Sep, 2026 |
- Included w.e.f.27.06.2025 |
| 4690 |
ALPHA TEST HOUSE PVT LTD, BAHADURGARH
| 8185306
| IS 16046 : Part 1 (2018) |
Secondary Cells and Batteries Containing Alkaline or Other Non-Acid Electrolytes ” Safety Requirements for Portable Sealed Secondary Cells and for Batteries Made from Them for Use in Portable Applications Part 1 Nickel Systems ( Second Revision ) |
All |
80000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4(Parameter Measurement Tolerances) |
- |
80000 |
|
- |
| 5(General Safety Considerations) |
- |
80000 |
|
- |
| 5.1(General) |
- |
80000 |
|
- |
| 5.2(Insulation and Wiring) |
- |
80000 |
|
- |
| 5.3(Venting) |
- |
80000 |
|
- |
| 5.4(Temperature, Voltage and Current Management) |
- |
80000 |
|
- |
| 5.5(Terminal Contacts) |
- |
80000 |
|
- |
| 5.6(Assembly of Cells into batteries) |
- |
80000 |
|
- |
| 5.7(Quality Plan) |
- |
80000 |
|
- |
| 6(Tyoe Test amd Sample Size) |
- |
80000 |
|
- |
| 7.1(Charging procedure for test purposes) |
- |
80000 |
|
- |
| 7.2(Intended Use) |
- |
80000 |
|
- |
| 7(Specific requirements and tests) |
- |
80000 |
|
- |
| 7.3(Reasonably foreseeable misuse) |
- |
80000 |
|
- |
| 8(Information for safety) |
- |
80000 |
|
- |
| 8.1(General) |
- |
80000 |
|
- |
| 8.2(Small Cell and battery safety information) |
- |
80000 |
|
- |
| 9(Marking) |
- |
80000 |
|
- |
| 9.1(Cell Marking) |
- |
80000 |
|
- |
| 9.2(Battery Marking) |
- |
80000 |
|
- |
| 9.3(Caution for ingestion of small cells and batteries) |
- |
80000 |
|
- |
| 9.4(Other information) |
- |
80000 |
|
- |
| 10(Packaging) |
- |
80000 |
|
- |
|
08 May, 2028 |
- Included w.e.f 20.06.2025 |
| 4691 |
ATCC TEST LABS LLP
| 8172626
| IS 2465 (1984) |
Specification for cables for motor vehicles (Second Revision) |
- |
30000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 7.1(Insulation) |
- |
500 |
|
- |
| 7.3(Insulation) |
- |
500 |
|
- |
| 8(Core Identification) |
- |
500 |
|
- |
| 9(Laying up of cores) |
- |
500 |
|
- |
| 10.1.1(Sheathing ) |
- |
500 |
|
- |
| 10.2(Sheathing ) |
- |
500 |
|
- |
| 3 & 6(Flexibility class) |
- |
500 |
|
- |
| 3 & 6(Construction) |
- |
500 |
|
- |
| 3 & 6(Diameter of wire(mm)) |
- |
1000 |
|
- |
| 3 & 6(Annealing test) |
- |
1000 |
|
- |
| 3 & 6(Persulphate Test) |
- |
1000 |
|
- |
| 3 & 6(Conductor resistance Test (ohm/km at 20˚c)) |
- |
1000 |
|
- |
| 7.2, 10.3, 11(Dimensions & thickness ) |
- |
1000 |
|
- |
| 7.2, 10.3, 11(Dimensions & thickness ) |
- |
1000 |
|
- |
| 7.2, 10.3, 11(Overall Dimension (mm)) |
- |
1000 |
|
- |
| 4.2 & 12.1(Without Ageing For Insulation
Tensile Strength (N/mm²)) |
- |
2000 |
|
- |
| 4.2 & 12.1, (f), 1(elongation at break (N/mm²)) |
- |
2000 |
|
- |
| 4.2 & 12.1, (f), 1(Tensile Strength at break (N/mm²)) |
- |
2000 |
|
- |
| 4.2 & 12.1, (e), 1(elongation test at break) |
- |
2000 |
|
- |
| 4.2 & 12.1, (e), 1(Tensile strength at break) |
- |
2000 |
|
- |
| 4.2 & 12.1, (f), 2(Ageing in air oven) |
- |
2000 |
|
- |
| 4.2 & 12.1, (f), 3(Ageing in oxygen bomb) |
- |
2000 |
|
- |
| 4.2 & 12.1, (e), 2(After Ageing in air oven) |
- |
2000 |
|
- |
| 4.2 & 12.1, (e), 3(Loss of mass test (mg/cm²) of Insulation) |
- |
2000 |
|
- |
| 4.2 & 12.1, (e), 3(Loss of mass test (mg/cm²) of Sheath) |
- |
2000 |
|
- |
| 4.2 & 12.1, (e), 4(Hot deformation test (%) of Insulation) |
- |
1000 |
|
- |
| 4.2 & 12.1, (e), 4(Hot deformation test (%) of Sheath) |
- |
1000 |
|
- |
| 4.2 & 12.1, (e), 5(Heat Shock Test of Insulation) |
- |
1000 |
|
- |
| 4.2 & 12.1, (e), 5(Heat Shock Test of Sheath) |
- |
1000 |
|
- |
| 4.2 & 12.1, (e), 6(Shrinkage Test (%) of Insulation) |
- |
1000 |
|
- |
| 4.2 & 12.1, (e), 6(Shrinkage Test (%) of Sheath) |
- |
1000 |
|
- |
| 14(High Voltage Test) |
- |
1000 |
|
- |
| 15(SPARK TEST FOR SINGLE CORE GENERAL WIRING CABLES) |
- |
1000 |
|
- |
| 16.1(CAPACITANCE TEST FOR PVC INSULATION IGNITION CABLE) |
- |
1000 |
|
- |
| 17.1(OZONE RESISTANCE TEST FOR IGNITION CABLES) |
- |
2000 |
|
- |
| 18.1(EFFECT OF HEAT ON FLEXIBILITY FOR IGNITION CABLES) |
- |
2000 |
|
- |
| 19.1(EFFECT OF OIL ON IGNITION CABLES) |
- |
2000 |
|
- |
| 19.2(EFFECT OF OIL ON IGNITION CABLES) |
- |
2000 |
|
- |
| 20.3(EFFECT OF LUBRICATING OIL) |
- |
2000 |
|
- |
| 20.3(EFFECT OF LUBRICATING OIL) |
- |
2000 |
|
- |
| 20.3(EFFECT OF BRAKE FLUID) |
- |
2000 |
|
- |
| 20.3(EFFECT OF BRAKE FLUID) |
- |
2000 |
|
- |
| 20.3(EFFECT OF DIESEL) |
- |
2000 |
|
- |
| 20.3(EFFECT OF DIESEL) |
- |
2000 |
|
- |
| 20.3(Increase in average diameter %) |
- |
1000 |
|
- |
| 20.3(Wrapping test) |
- |
1000 |
|
- |
| 21.1(EFFECT OF COOLING ON FLEXIBILITY) |
- |
2000 |
|
- |
| 21.2(EFFECT OF COOLING ON FLEXIBILITY) |
- |
2000 |
|
- |
| 21.2(EFFECT OF COOLING ON FLEXIBILITY) |
- |
2000 |
|
- |
| 22.1(FLAMMABILITY TEST) |
- |
1000 |
|
- |
| 22.1(FLAMMABILITY TEST) |
- |
1000 |
|
- |
| 23.1(Manufacturer's Identification) |
- |
500 |
|
- |
| 23.1(Manufacturer's Identification) |
- |
500 |
|
- |
| 24.1(PACKING AND MARKING) |
- |
500 |
|
- |
| 24.2(PACKING AND MARKING) |
- |
500 |
|
- |
| 24.2.1(PACKING AND MARKING) |
- |
500 |
|
- |
| 12.1.b(Persulphate test (when
applicable)) |
- |
1000 |
|
- |
| 6.1, 12.3, 12.1.c(Conductor Resistance) |
- |
1000 |
|
- |
| 12.1.e4(Hot deformation) |
- |
1000 |
|
- |
| 12.1.e5(Heat Shock) |
- |
1000 |
|
- |
| CL.12.1 (e) 2(Tensile Strength After Ageing) |
- |
2000 |
|
- |
| CL.12.1 (e) 2(Elongation After Ageing) |
- |
2000 |
|
- |
| CL.12.1 (e) 2(Tensile Strength Variation) |
- |
2000 |
|
- |
| CL.12.1 (e) 2(Elongation Variation) |
- |
2000 |
|
- |
| CL.12.1 (e) 2(Elongation Variation) |
- |
2000 |
|
- |
| Cl.12 (e) 5(Heat shock test) |
- |
1000 |
|
- |
| Cl.12 (e) 4(Hot Deformation Test) |
- |
1000 |
|
- |
| Cl.12 (e) 6(Shrinkage Test) |
- |
1000 |
|
- |
| Cl.12 (e) 6(Shrinkage Test (Cracks Observed)) |
- |
1000 |
|
- |
| Cl. 12.1 (e) 3(Loss of Mass Insulation) |
- |
2000 |
|
- |
|
- |
- Included w.e.f 14.08.2025 |
| 4692 |
ATCC TEST LABS LLP
| 8172626
| IS 9968 : Part 1 (1988) |
Specification for elastomer insulatedcables: Part 1 for working voltages up to and including 1100 volts (First Revision) |
- |
10500 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 3.1( Copper Cooduetor) |
- |
500 |
|
- |
| 3.2(Aluminium conductor) |
- |
500 |
|
- |
| 4.1(INSULATION : lnsulation for General Service) |
- |
500 |
|
- |
| 4.2(INSULATION : Heat Resisting insulation) |
- |
500 |
|
- |
| 4.3(INSULATION : Silicone Rubber Insulation) |
- |
500 |
|
- |
| 5.1(TAPE : Proofed Tape) |
- |
500 |
|
- |
| 5.2(TAPE : 2 Polyethyl_ Terephthalate ( PETP ) Tape or
Plastic: Tape or Any Other SlIIitable Tape ) |
- |
500 |
|
- |
| 5.3(TAPE : Giass Tape) |
- |
500 |
|
- |
| 6.1(FILLERS : ) |
- |
500 |
|
- |
| 7.1(BRAID : Textile Braid) |
- |
500 |
|
- |
| 7.2(BRAID : Glass Braid ) |
- |
500 |
|
- |
| 8.1(SHEATH : General Service Insulated Cables and Flexible
Cords) |
- |
500 |
|
- |
| 8.2(SHEATH :Heat Resisting Insulated Cables) |
- |
500 |
|
- |
| 9.1(PresenRtive Compound) |
- |
500 |
|
- |
| 9.2(Varnish) |
- |
500 |
|
- |
| 10( Conductor ) |
- |
500 |
|
- |
| 11(Separator tape) |
- |
500 |
|
- |
| 12.2(Insulation : Thickness of Insufatien) |
- |
1000 |
|
- |
| 12.4(Insulation : Allplication of Insulation) |
- |
1000 |
|
- |
| 13(CORE IDENTiFICATlON) |
- |
500 |
|
- |
| 14(Tape) |
- |
500 |
|
- |
| 15(BRAIDING) |
- |
500 |
|
- |
| 16(COMPOUNDING AND VARNISHING) |
- |
500 |
|
- |
| 17(LAYING UP OF CORES) |
- |
500 |
|
- |
| 18( Binder tape) |
- |
500 |
|
- |
| 19.2(Sheath : Thickness of Sheath) |
- |
1000 |
|
- |
| 19.4( Sheath :Colour) |
- |
500 |
|
- |
| 20( Overall diameter) |
- |
1000 |
|
- |
| 21. (a)(Persulphate tests (for copper)) |
- |
2000 |
|
- |
| 21. (b)(Annealing Test (for coper)) |
- |
1000 |
|
- |
| 21. (c)( Tensile Test (for aluminium)) |
- |
1000 |
|
- |
| 21. (d)( Wrapping Test (for aluminium)) |
- |
1000 |
|
- |
| 21. (e)(Conductor Resistance ) |
- |
1000 |
|
- |
| 21.1( Tensile strength ) |
- |
1000 |
|
- |
| 22.1( Elongation) |
- |
1000 |
|
- |
| 21.1(type test : Ageing In air oven) |
- |
2000 |
|
- |
| 21.1(type test : Ageing in air bomb) |
- |
2000 |
|
- |
| 21.1(type test : Ageing In oxygen
bomb) |
- |
2000 |
|
- |
| 21.1(type test : Hot set elongation) |
- |
1000 |
|
- |
| 21.1(type test : Tear resistance ) |
- |
1000 |
|
- |
| 22.2(type test :Insulauon resistance High voltage (water immersron ) test) |
- |
1000 |
|
- |
| 22.2(type test : Flammability test
( applicable to cables
finished With SE 3 and
SE 4 sheaths only)
) |
- |
1000 |
|
- |
| 21(Water absorption test) |
- |
2000 |
|
- |
| 23(identification) |
- |
500 |
|
- |
| Cl No. 4.1(Ageing in oxygen bomb - Elongation) |
- |
2000 |
|
- |
| Cl No. 4.1(Ageing in oxygen bomb - Tensile strength ) |
- |
2000 |
|
- |
| Cl No. 4.1(Ageing in air bomb - Elongation) |
- |
2000 |
|
- |
| Cl No. 4.1(Ageing in air bomb - Tensile strength ) |
- |
2000 |
|
- |
| Cl No. 4.1(Ageing in air oven - Elongation) |
- |
2000 |
|
- |
| Cl No. 4.1(Ageing in air oven - Tensile strength ) |
- |
2000 |
|
- |
| Cl No. 22.2(High Voltage Test (Water Immersion)) |
- |
1000 |
|
- |
| Cl No. 4.1(Insulation resistance) |
- |
1000 |
|
- |
| Cl No. 22.4, Appendix B (Flexing test for cords for use with electric iron ) |
- |
2000 |
|
- |
| Cl No. 22.2.2/22.2.3(High Voltage Test / Spark test) |
- |
1000 |
|
- |
| Cl No. 23.1, 23.2(Identification) |
- |
500 |
|
- |
| 21.1((f) Oil resistance) |
- |
2000 |
|
- |
| Cl.9.1(Compound and Varnish) |
- |
500 |
|
- |
| Cl.9.2(Compound and Varnish) |
- |
500 |
|
- |
| Cl.21.1 & Table 2 of IS: 6380-1984(Water Absorption Test) |
- |
3000 |
|
- |
| Cl.19.1(Application of Sheath) |
- |
500 |
|
- |
| Cl.21.1 & Table 3 of IS: 6380-1984(Physical Test on outer sheath (Without Ageing)) |
- |
1000 |
|
- |
| Cl.21.1 & Table 3 of IS: 6380-1984(Physical Test on outer sheath (Without Ageing)) |
- |
1000 |
|
- |
| Cl.21.1 & Table 3 of IS: 6380-1984(Physical Test on outer sheath (Without Ageing)) |
- |
1000 |
|
- |
| Cl.21.1 & Table 3 of IS: 6380-1984(Physical Test on outer sheath (After ageing in air oven)) |
- |
1000 |
|
- |
| Cl.21.1 & Table 3 of IS: 6380-1984(Physical Test on outer sheath (After ageing in air oven)) |
- |
1000 |
|
- |
| Cl.21.1 & Table 3 of IS: 6380-1984(Physical Test on outer sheath (After ageing in air Bomb )) |
- |
1000 |
|
- |
| Cl.21.1 & Table 3 of IS: 6380-1984(Physical Test on outer sheath (After ageing in air Bomb )) |
- |
1000 |
|
- |
| Cl.21.1 & Table 3 of IS: 6380-1984(Physical Test on outer sheath (Oil Resistance Test )) |
- |
1000 |
|
- |
| Cl.21.1 & Table 3 of IS: 6380-1984(Physical Test on outer sheath (Oil Resistance Test )
Variation on Elongation (Percentage)) |
- |
1000 |
|
- |
| Cl.21.1 & Table 3 of IS: 6380-1984(Physical Test on outer sheath (Hot Set Test)) |
- |
1000 |
|
- |
| Cl.21.1 & Table 3 of IS: 6380-1984(Physical Test on outer sheath (Hot Set Test)) |
- |
1000 |
|
- |
| Cl.21.1 & Table 2 of IS: 6380-1984(Insulation Resistance Test) |
- |
1000 |
|
- |
| Cl.21.1 & Table 2 of IS: 6380-1984(Insulation Resistance Test) |
- |
1000 |
|
- |
|
- |
- Included w.e.f 14.08.2025 |
| 4693 |
ALPHA TEST HOUSE PVT LTD, BAHADURGARH
| 8185306
| IS 302 : Part 2 : Sec 80 (2017) |
Household and similar electrical appliances - Safety: Part 2 - 80 particular requirements for fans (First Revision) |
- |
208300 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 32.0(Radiation, Toxicity and Similar Hazards) |
- |
28300 |
|
Extra EMI/EMC charges: 1,80,000 |
| 31.0(Resistance To Rusting) |
- |
28300 |
|
Extra EMI/EMC charges: 1,80,000 |
| 30.0(Resistance To Heat and Fire) |
- |
28300 |
|
Extra EMI/EMC charges: 1,80,000 |
| 29.0(Creepage Distances and Clearances) |
- |
28300 |
|
Extra EMI/EMC charges: 1,80,000 |
| 28.0(Screws and Connections) |
- |
28300 |
|
Extra EMI/EMC charges: 1,80,000 |
| 27.0(Provision For Earthing) |
- |
28300 |
|
Extra EMI/EMC charges: 1,80,000 |
| 26.0(Terminals for external conductors) |
- |
28300 |
|
Extra EMI/EMC charges: 1,80,000 |
| 25.0(Supply Connection and External Flexible Cords) |
- |
28300 |
|
Extra EMI/EMC charges: 1,80,000 |
| 24.0(Components) |
- |
28300 |
|
Extra EMI/EMC charges: 1,80,000 |
| 23.0(Internal Wiring) |
- |
28300 |
|
Extra EMI/EMC charges: 1,80,000 |
| 22.0(Construction) |
- |
28300 |
|
Extra EMI/EMC charges: 1,80,000 |
| 21.0(Mechanical Strength) |
- |
28300 |
|
Extra EMI/EMC charges: 1,80,000 |
| 20.0(Stability and mechanical hazards) |
- |
28300 |
|
Extra EMI/EMC charges: 1,80,000 |
| 19.0(Abnormal Operation) |
- |
28300 |
|
Extra EMI/EMC charges: 1,80,000 |
| 17.0(Overload Protection of transformer and associated circuit) |
- |
28300 |
|
Extra EMI/EMC charges: 1,80,000 |
| 16.0(Leakage current and Electric strength (After Humidity (Environmental) Treatment)) |
- |
28300 |
|
Extra EMI/EMC charges: 1,80,000 |
| 15.0(Moisture resistance) |
- |
28300 |
|
Extra EMI/EMC charges: 1,80,000 |
| 14.0(Transient Overvoltage) |
- |
28300 |
|
Extra EMI/EMC charges: 1,80,000 |
| 13.0(Leakage Current and electric strength at operating temperature) |
- |
28300 |
|
Extra EMI/EMC charges: 1,80,000 |
| 11.0(Heating) |
- |
28300 |
|
Extra EMI/EMC charges: 1,80,000 |
| 10.0(Input and Current) |
- |
28300 |
|
Extra EMI/EMC charges: 1,80,000 |
| 8.0(Protection against access to live parts) |
- |
28300 |
|
Extra EMI/EMC charges: 1,80,000 |
| 7.0(Classification) |
- |
28300 |
|
Extra EMI/EMC charges: 1,80,000 |
| 6.0(Marking and Instructions) |
- |
28300 |
|
Extra EMI/EMC charges: 1,80,000 |
| 19.11.4.1(Electrostatic discharges) |
- |
208300 |
|
- |
| 19.11.4.2(Radiated fields) |
- |
208300 |
|
- |
| 19.11.4.3(Fast transient bursts) |
- |
208300 |
|
- |
| 19.11.4.4(Surge immunity test) |
- |
208300 |
|
- |
| 19.11.4.5(Immunity to conducted discharges) |
- |
208300 |
|
- |
| 19.11.4.6(Class 3 Voltage dips and interruptions) |
- |
208300 |
|
- |
| 19.11.4.7(Harmonics) |
- |
208300 |
|
- |
| 4(GENERAL REQUIREMENT) |
- |
28300 |
|
Extra EMI/EMC charges: 1,80,000 |
| 5(GENERAL CONDITIONS FOR THE TESTS) |
- |
28300 |
|
Extra EMI/EMC charges: 1,80,000 |
|
08 May, 2028 |
- Included w.e.f.19.06.2025 |
| 4694 |
Sleen India Biz venture Private Limited, Agra
| 9139736
| IS 16948 (2018) |
Medical textile – Permeable nonwoven surgical adhesive tape – Specification |
- |
7500 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4.1 and 4.2(Workmanship and finish) |
- |
500 |
|
- |
| 5.1 - Table 1 -(i)(Weight of backing material) |
- |
1250 |
|
- |
| 5.1 - Table 1 -(ii)(Weight of adhesive mass) |
- |
1250 |
|
- |
| 5.1 - Table 1 -(iii)(Water vapour permeability) |
- |
1000 |
|
- |
| 5.1 - Table 1 -(iv)(Adhesiveness) |
- |
2000 |
|
- |
| 5.1 - Table 1 -(v)(Width of the tape) |
- |
500 |
|
- |
| 6(Marking) |
- |
300 |
|
- |
| 5.1 - Table 1 -(v)(Width of the tape) |
- |
0 |
|
- |
| 5.1 - Table 1 -(vi)(Perforations) |
- |
500 |
|
- |
| 6(Marking) |
- |
0 |
|
- |
| 8(Packing) |
- |
200 |
|
- |
| 4(Workmanship and finish) |
- |
0 |
|
- |
| 5- Table-1- i)(Weight of backing material) |
- |
0 |
|
- |
| 5- Table-1- ii)(Weight of adhesive mass) |
- |
0 |
|
- |
| 5- Table-1- iii)(Water vapour permeability) |
- |
0 |
|
- |
| 5- Table-1- iv)(Adhesiveness) |
- |
0 |
|
- |
| 5- Table-1- v)(Width of the tape) |
- |
0 |
|
- |
| 5- Table-1- vi)(Width of the tape) |
- |
0 |
|
- |
| 6(Marking) |
- |
0 |
|
- |
| 8(Packing) |
- |
0 |
|
- |
|
- |
- Included w.e.f.23.06.2025 |
| 4695 |
JBS TESTING SOLUTIONS PVT LTD (27), JALANDHAR
| 9164606
| IS 9139 (2023) |
MALLEABLE IRON SHOTS AND GRITS FOR USE IN FOUNDRIES � SPECIFICATION |
- |
27500 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl-4(General requirements) |
- |
27500 |
|
For complete testing |
| Cl-5(MANUFACTURE) |
- |
27500 |
|
For complete testing |
| Cl-6.1(Shot) |
- |
27500 |
|
For complete testing |
| Cl-6.2(Grit) |
- |
27500 |
|
For complete testing |
| Cl-7(Size) |
- |
27500 |
|
For complete testing |
| Cl-8 (i)(Carbon) |
- |
27500 |
|
For complete testing |
| Cl-8 (ii)(Silicon) |
- |
27500 |
|
For complete testing |
| Cl-8 (iii)(Manganese) |
- |
27500 |
|
For complete testing |
| Cl-8 (iv)(Sulphur) |
- |
27500 |
|
For complete testing |
| Cl-8 (v)(Phosphorus) |
- |
27500 |
|
For complete testing |
| Cl-9(Hardness) |
- |
27500 |
|
For complete testing |
| Cl-10(Microstructure) |
- |
27500 |
|
For complete testing |
| Cl-11(Specific gravity) |
- |
27500 |
|
For complete testing |
| Cl-14(Marking) |
- |
27500 |
|
For complete testing |
|
- |
- Included w.e.f 30.05.2025 |
| 4696 |
Bharat Test House Pvt. Ltd. 1668 Sonipat
| 9168306
| IS 17155 (2019) |
Tricycle, single hand propelled (?Right?/?Left?) (?Junior Size?) ? specification |
- |
40000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 3(NOMENCLATURE) |
- |
1000 |
|
- |
| 4(The typical shape and dimensions) |
- |
1000 |
|
- |
| 5.1(Tubing) |
- |
1000 |
|
- |
| 5.2(Seat) |
- |
1000 |
|
- |
| 5.2(Standard tricycle components) |
- |
1000 |
|
- |
| 5.3.1(Seat) |
- |
1000 |
|
- |
| 5.3.1(Expanded vinyl coated fabrics) |
- |
1000 |
|
- |
| 5.3.2(Back rest thickness) |
- |
1000 |
|
- |
| 5.3.2(Expanded vinyl coated fabrics) |
- |
1000 |
|
- |
| 5.4.1(Foot rest) |
- |
1000 |
|
- |
| 5.4.2(Seat walls) |
- |
1000 |
|
- |
| 5.4.2(mild steel CRA sheet grade ‘0’) |
- |
1000 |
|
- |
| 5.4.3(Tool box) |
- |
500 |
|
- |
| 5.5(Spring wire) |
- |
500 |
|
- |
| 5.6(Other metallic components) |
- |
1000 |
|
- |
| 5.7(Timber) |
- |
2500 |
|
- |
| 5.8(Bearing Balls) |
- |
500 |
|
- |
| 6.1(Frame) |
- |
500 |
|
- |
| 6.2(Steering handle Bar) |
- |
500 |
|
- |
| 6.3(Tyres and Tubes) |
- |
1000 |
|
- |
| 6.4(4 Wheel Rims) |
- |
500 |
|
- |
| 6.4(Spokes diameter) |
- |
500 |
|
- |
| 6.5(Mudguards) |
- |
500 |
|
- |
| 6.6(Brake) |
- |
500 |
|
- |
| 6.7(Sprocket and free wheel) |
- |
1000 |
|
- |
| 6.8(Front wheel hub) |
- |
1000 |
|
- |
| 6.9(Rear wheel hub) |
- |
2000 |
|
- |
| 6.1(Drive Chain) |
- |
1000 |
|
- |
| 6.11(Tool Box) |
- |
500 |
|
- |
| 6.12(Lubrication) |
- |
500 |
|
- |
| 6.13(Suitable means) |
- |
1000 |
|
- |
| 6.14(Accessories) |
- |
500 |
|
- |
| 6.15(Servicing and adjustment) |
- |
1000 |
|
- |
| 7.1(Frame of the tricycle and mudguards, prior to assembly) |
- |
500 |
|
- |
| 7.2(All the metallic parts) |
- |
500 |
|
- |
| 7.2(All the metallic parts) |
- |
500 |
|
- |
| 8.1(Road Test) |
- |
2500 |
|
- |
| 8.2(Maneuverabilit) |
- |
2500 |
|
- |
| 8.3(Static Load Test) |
- |
2500 |
|
- |
| 8.4(Brake test) |
- |
2500 |
|
- |
| 8.5(Test for finish) |
- |
500 |
|
- |
| 9.1(The tricycle shall be marked) |
- |
100 |
|
- |
| 10(Packing) |
- |
100 |
|
- |
| 4(Shape and Dimension) |
- |
1000 |
|
- |
| 5.1(Tubing) |
- |
1000 |
|
- |
| 5.2(Standard tricycle components) |
- |
1000 |
|
- |
| 5.3(Seat and Back test) |
- |
1000 |
|
- |
| 5.4(Footrest, Seat Walls & Tool box) |
- |
1000 |
|
- |
| 5.5(Spring wire) |
- |
1000 |
|
- |
| 5.7(Timber) |
- |
1000 |
|
- |
| 5.8(Bearing Balls) |
- |
1000 |
|
- |
| 6.1(Frame) |
- |
1000 |
|
- |
| 6.2(Steering handle Bar) |
- |
500 |
|
- |
| 6.3(Tyres and Tubes) |
- |
1000 |
|
- |
| 6.4(Wheel Rims) |
- |
500 |
|
- |
| 6.4(Spokes diameter) |
- |
500 |
|
- |
| 6.5(Mudguards) |
- |
500 |
|
- |
| 6.6(Brake) |
- |
500 |
|
- |
| 6.7(Sprocket and free wheel) |
- |
1000 |
|
- |
| 6.8(Front wheel hub) |
- |
1000 |
|
- |
| 6.9(Rear wheel hub) |
- |
2000 |
|
- |
| 6.1(Drive Chain) |
- |
500 |
|
- |
| 6.11(Tool Box) |
- |
500 |
|
- |
| 6.12(Lubrication) |
- |
500 |
|
- |
| 6.14(Accessories) |
- |
100 |
|
- |
| 6.15(Servicing and adjustment) |
- |
100 |
|
- |
| 7(Finish) |
- |
500 |
|
- |
| 8.1(Road Test) |
- |
2500 |
|
- |
| 8.2(Maneuverability) |
- |
2500 |
|
- |
| 8.3(Static Load Test) |
- |
2500 |
|
- |
| 8.4(Brake test) |
- |
2500 |
|
- |
| 8.5(Test for finish) |
- |
500 |
|
- |
| 9(Marking) |
- |
500 |
|
- |
| 3(NOMENCLATURE) |
- |
0 |
|
- |
| 4(The typical shape and dimensions) |
- |
0 |
|
- |
| 5.1(Tubing) |
- |
0 |
|
- |
| 5.2(Seat) |
- |
0 |
|
- |
| 5.2(Standard tricycle components) |
- |
0 |
|
- |
| 5.3.1(Seat) |
- |
0 |
|
- |
| 5.3.1(Expanded vinyl coated fabrics) |
- |
0 |
|
- |
| 5.3.2(Back rest thickness) |
- |
0 |
|
- |
| 5.3.2(Expanded vinyl coated fabrics) |
- |
0 |
|
- |
| 5.4.1(Foot rest) |
- |
0 |
|
- |
| 5.4.2(Seat walls) |
- |
0 |
|
- |
| 5.4.2(mild steel CRA sheet grade ‘0’) |
- |
0 |
|
- |
| 5.4.3(Tool box) |
- |
0 |
|
- |
| 5.5(Spring wire) |
- |
0 |
|
- |
| 5.6(Other metallic components) |
- |
0 |
|
- |
| 5.7(Timber) |
- |
0 |
|
- |
| 5.8(Bearing Balls) |
- |
0 |
|
- |
| 6.1(Frame) |
- |
0 |
|
- |
| 6.2(Steering handle Bar) |
- |
0 |
|
- |
| 6.3(Tyres and Tubes) |
- |
0 |
|
- |
| 6.4(4 Wheel Rims) |
- |
0 |
|
- |
| 6.4(Spokes diameter) |
- |
0 |
|
- |
| 6.5(Mudguards) |
- |
0 |
|
- |
| 6.6(Brake) |
- |
0 |
|
- |
| 6.7(Sprocket and free wheel) |
- |
0 |
|
- |
| 6.8(Front wheel hub) |
- |
0 |
|
- |
| 6.9(Rear wheel hub) |
- |
0 |
|
- |
| 6.1(Drive Chain) |
- |
0 |
|
- |
| 6.11(Tool Box) |
- |
0 |
|
- |
| 6.12(Lubrication) |
- |
0 |
|
- |
| 6.13(Suitable means) |
- |
0 |
|
- |
| 6.14(Accessories) |
- |
0 |
|
- |
| 6.15(Servicing and adjustment) |
- |
0 |
|
- |
| 7.1(Frame of the tricycle and mudguards, prior to assembly) |
- |
0 |
|
- |
| 7.2(All the metallic parts) |
- |
0 |
|
- |
| 7.2(All the metallic parts) |
- |
0 |
|
- |
| 8.1(Road Test) |
- |
0 |
|
- |
| 8.2(Maneuverabilit) |
- |
0 |
|
- |
| 8.3(Static Load Test) |
- |
0 |
|
- |
| 8.4(Brake test) |
- |
0 |
|
- |
| 8.5(Test for finish) |
- |
0 |
|
- |
| 9.1(The tricycle shall be marked) |
- |
0 |
|
- |
| 10(Packing) |
- |
0 |
|
- |
| 4(Shape and Dimension) |
- |
0 |
|
- |
| 5.1(Tubing) |
- |
0 |
|
- |
| 5.2(Standard tricycle components) |
- |
0 |
|
- |
| 5.3(Seat and Back test) |
- |
0 |
|
- |
| 5.4(Footrest, Seat Walls & Tool box) |
- |
0 |
|
- |
| 5.5(Spring wire) |
- |
0 |
|
- |
| 5.7(Timber) |
- |
0 |
|
- |
| 5.8(Bearing Balls) |
- |
0 |
|
- |
| 6.1(Frame) |
- |
0 |
|
- |
| 6.2(Steering handle Bar) |
- |
0 |
|
- |
| 6.3(Tyres and Tubes) |
- |
0 |
|
- |
| 6.4(Wheel Rims) |
- |
0 |
|
- |
| 6.4(Spokes diameter) |
- |
0 |
|
- |
| 6.5(Mudguards) |
- |
0 |
|
- |
| 6.6(Brake) |
- |
0 |
|
- |
| 6.7(Sprocket and free wheel) |
- |
0 |
|
- |
| 6.8(Front wheel hub) |
- |
0 |
|
- |
| 6.9(Rear wheel hub) |
- |
0 |
|
- |
| 6.1(Drive Chain) |
- |
0 |
|
- |
| 6.11(Tool Box) |
- |
0 |
|
- |
| 6.12(Lubrication) |
- |
0 |
|
- |
| 6.14(Accessories) |
- |
0 |
|
- |
| 6.15(Servicing and adjustment) |
- |
0 |
|
- |
| 7(Finish) |
- |
0 |
|
- |
| 8.1(Road Test) |
- |
0 |
|
- |
| 8.2(Maneuverability) |
- |
0 |
|
- |
| 8.3(Static Load Test) |
- |
0 |
|
- |
| 8.4(Brake test) |
- |
0 |
|
- |
| 8.5(Test for finish) |
- |
0 |
|
- |
| 9(Marking) |
- |
0 |
|
- |
|
- |
- Included w.e.f.28.07.2025 |
| 4697 |
Atmy Analytical Labs Pvt. Ltd., Faridabad
| 8167506
| IS 14625 (2015) |
Plastics Feeding Bottles ( First Revision ) |
- |
20800 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl 5.1(Physical Requirements) |
- |
1000 |
|
- |
| Cl 5.1.3(Wall Thickness) |
- |
2000 |
|
- |
| Cl 5.1.4(Capacity) |
- |
1500 |
|
- |
| Cl 5.3.2(Transparecy) |
- |
2000 |
|
- |
| Cl 5.3.3(Leakage Test) |
- |
2000 |
|
- |
| Cl 5.3.4(Drop Test) |
- |
2000 |
|
- |
| Cl 5.3.5(Ageing Resistance) |
- |
2000 |
|
- |
| Cl 5.3.6(Compressive Deformation Resistance) |
- |
2000 |
|
- |
| Cl 5.3.7(Product Resistance of Printed Containers) |
- |
2000 |
|
- |
| Cl 5.1.3(Wall Thickness) |
- |
0 |
|
- |
| Cl 5.1.4(Capacity) |
- |
0 |
|
- |
| Cl 5.3.2(Transparecy) |
- |
0 |
|
- |
| Cl 5.3.3(Leakage Test) |
- |
0 |
|
- |
| Cl 5.3.4(Drop Test) |
- |
0 |
|
- |
| Cl 5.3.5(Ageing Resistance) |
- |
0 |
|
- |
| Cl 5.3.6(Compressive Deformation Resistance) |
- |
0 |
|
- |
| Cl 5.3.7(Product Resistance of Printed Containers) |
- |
0 |
|
- |
| Cl 5.1(Physical Requirements) |
- |
0 |
|
- |
| Cl 5.1.3(Wall Thickness) |
- |
0 |
|
- |
| Cl 5.1.4(Capacity) |
- |
0 |
|
- |
| Cl 5.3.2(Transparecy) |
- |
0 |
|
- |
| Cl 5.3.3(Leakage Test) |
- |
0 |
|
- |
| Cl 5.3.4(Drop Test) |
- |
0 |
|
- |
| Cl 5.3.5(Ageing Resistance) |
- |
0 |
|
- |
| Cl 5.3.6(Compressive Deformation Resistance) |
- |
0 |
|
- |
| Cl 5.3.7(Product Resistance of Printed Containers) |
- |
0 |
|
- |
| Sl. No. i), Table 1, Cl.5.2.1.7(Migration of certain elements - Antimony) |
- |
4500 |
|
Table 1, S.no (i) to (viii)- Rs 4500/- |
| Sl. No. i), Table 1, Cl.5.2.1.7(Migration of certain elements - Arsenic) |
- |
0 |
|
- |
| Sl. No. i), Table 1, Cl.5.2.1.7(Migration of certain elements - Chromium) |
- |
0 |
|
- |
| Sl. No. i), Table 1, Cl.5.2.1.7(Migration of certain elements - Mercury) |
- |
0 |
|
- |
| 4.1(Material Identification, Bisphenol A,) |
- |
4000 |
|
- |
| 4.2(Rubber Teats for Feeding bottle shall conform to IS 3565 (Workmanship and Finish, Acetone Extract, Free sulphur in Acetone Extract, Change in Physical property, Properties of Water Extract, pH of the Water Extract, Tension Set )) |
- |
0 |
|
- |
| 5.1.1(Description, Design, shape & dimensions) |
- |
1000 |
|
- |
| 5.3.1(Environmental Stress Crack Resistance,) |
- |
2000 |
|
- |
| Clauses 5.3.9.2 and 5.3.9.3,Table 3, S.no.(ix)(Phthalic acid, bis(2-ethylhexyl)ester (DEHP)-ISO 18856) |
- |
5500 |
|
Cl. 5.3.9 table 3 s.no. (i) to (ix)- Rs 5500/- |
| Sl. No. i), Table 1, Cl.5.2.1.7(Migration of certain elements - Cadmium) |
- |
0 |
|
- |
| Sl. No. i), Table 1, Cl.5.2.1.7(Migration of certain elements - Lead) |
- |
0 |
|
- |
| Sl. No. i), Table 1, Cl.5.2.1.7(Migration of certain elements - Barium) |
- |
0 |
|
- |
| Sl. No. i), Table 1, Cl.5.2.1.7(Migration of certain elements - Selenium) |
- |
0 |
|
- |
| Cl 5.1.4.2 (a)(Test for permanency of Pigment) |
- |
1500 |
|
- |
| 5.3.8 a)(Migration Test a) Distilled water at 40±2° hrs) |
- |
2500 |
|
Cl. 5.3.8 (a) and (b)- total Rs 2500/- |
| 5.3.8 b)(Migration Test b) n-Haptane at 38±1° C for 30 min) |
- |
0 |
|
- |
| 5.1.2(Manufacture, workmanship finish & appearance) |
- |
1500 |
|
- |
| Clause 5.3.1(Environmental Stress crack resistance) |
- |
0 |
|
- |
| Clause 5.1.4.2(Capacity Scale) |
- |
0 |
|
- |
| Clause 5.1.2.2(Workmanship.Finish and Appearance) |
- |
0 |
|
- |
| Clause 5.1.1 (Description) |
- |
0 |
|
- |
| Clause 4.2 (Teats) |
- |
0 |
|
IS 14625-Total 20800 Rs/- exclude IS 3565 |
| Cl 5.3.7(Product Resistance of Printed Containers) |
- |
0 |
|
- |
| Cl 5.3.6(Compressive Deformation Resistance) |
- |
0 |
|
- |
| Cl 5.3.5(Ageing Resistance) |
- |
0 |
|
- |
| Cl 5.3.4(Drop Test) |
- |
0 |
|
- |
| Cl 5.3.3(Leakage Test) |
- |
0 |
|
- |
| Cl 5.3.2(Transparecy) |
- |
0 |
|
- |
| Cl 5.1.4(Capacity) |
- |
0 |
|
- |
| Cl 5.1.3(Wall Thickness at Top, Middle & Bottom ( Take every position 4 measurment and average will be reported)) |
- |
0 |
|
- |
| Cl 5.1(Physical Requirements) |
- |
0 |
|
- |
| "IS 14625:2015 RA2020 Sub-clause 4.0 "(Material Identification) |
- |
0 |
|
- |
| Cl 5.1(Physical Requirements) |
- |
0 |
|
- |
| Cl 5.1.3(Wall Thickness) |
- |
0 |
|
- |
| Cl 5.1.4(Capacity) |
- |
0 |
|
- |
| Cl 5.3.2(Transparecy) |
- |
0 |
|
- |
| Cl 5.3.3(Leakage Test) |
- |
0 |
|
- |
| Cl 5.3.4(Drop Test) |
- |
0 |
|
- |
| Cl 5.3.5(Ageing Resistance) |
- |
0 |
|
- |
| Cl 5.3.6(Compressive Deformation Resistance) |
- |
0 |
|
- |
| Cl 5.3.7(Product Resistance of Printed Containers) |
- |
0 |
|
- |
| "IS 14625:2015 RA2020 Sub-clause 4.0 "(Material Identification) |
- |
0 |
|
- |
| Cl.5.2.1.7, Table-1(i)(Migration of certain elements, Reqiurement as per table 1, Arsenic) |
- |
0 |
|
- |
| Cl.5.2.1.7, Table-1(ii)(Migration of certain elements, Reqiurement as per table 1, Chromium) |
- |
0 |
|
- |
| Cl.5.2.1.7, Table-1(iii)(Migration of certain elements, Reqiurement as per table 1, Mercury) |
- |
0 |
|
- |
| Cl.5.2.1.7, Table-1(iv)(Migration of certain elements, Reqiurement as per table 1, Cadmium) |
- |
0 |
|
- |
| Cl.5.2.1.7, Table-1(v)(Migration of certain elements, Reqiurement as per table 1, Lead) |
- |
0 |
|
- |
| Cl.5.2.1.7, Table-1(vi)(Migration of certain elements, Reqiurement as per table 1, Barium) |
- |
0 |
|
- |
| Cl.5.2.1.7, Table-1(vii)(Migration of certain elements, Reqiurement as per table 1, Selenium) |
- |
0 |
|
- |
| Cl.5.3.8(Migration test a)Distilled water) |
- |
0 |
|
- |
| Cl.5.3.8(Migration test a)n-Heptane) |
- |
0 |
|
- |
| Cl.5.3.9.2, Table-3(i)(Specific migration , Barium) |
- |
0 |
|
- |
| Cl.5.3.9.2, Table-3(ii)(Specific migration , Cobalt) |
- |
0 |
|
- |
| Cl.5.3.9.2, Table-3(iii)(Specific migration , Copper) |
- |
0 |
|
- |
| Cl.5.3.9.2, Table-3(iv)(Specific migration , Iron) |
- |
0 |
|
- |
| Cl.5.3.9.2, Table-3(v)(Specific migration , Lithium) |
- |
0 |
|
- |
| Cl.5.3.9.2, Table-3(vi)(Specific migration , Manganese) |
- |
0 |
|
- |
| Cl.5.3.9.2, Table-3(vii)(Specific migration , Zinc) |
- |
0 |
|
- |
| Cl.5.3.9.2, Table-3(viii)(Specific migration , Antimony) |
- |
0 |
|
- |
| Clause 5.2.1.7, S.No.(i)(Heavy metal,Antimony) |
- |
0 |
|
- |
| Clause 5.2.1.7, S.No.(ii)(Heavy metal,Arsenic) |
- |
0 |
|
- |
| Clause 5.2.1.7, S.No.(iii)(Heavy metal,Chromium) |
- |
0 |
|
- |
| Clause 5.2.1.7, S.No.(iv)(Heavy metal,Mercury) |
- |
0 |
|
- |
| Clause 5.2.1.7, S.No.(v)(Heavy metal,Cadmium) |
- |
0 |
|
- |
| Clause 5.2.1.7, S.No.(vi)(Heavy metal,Lead) |
- |
0 |
|
- |
| Clause 5.2.1.7, S.No.(vii)(Heavy metal,Barium) |
- |
0 |
|
- |
| Clause 5.2.1.7, S.No.(viii)(Heavy metal,Selenium) |
- |
0 |
|
- |
| Cl-5.2.1.2.2(pH meter) |
- |
0 |
|
- |
| Cl-5.2.1.2.3(Membrane filter) |
- |
0 |
|
- |
| Cl-5.2.1.2.4(Centrifuge) |
- |
0 |
|
- |
| Cl-5.2.1.3(Reagents) |
- |
0 |
|
- |
| Cl-5.2.1.3.1(Hydrochloric acid solution) |
- |
0 |
|
- |
| Cl-5.2.1.3.2(Hydrochloric acid solution) |
- |
0 |
|
- |
| Cl-7(Packing and Marking) |
- |
0 |
|
- |
| Sl. No. i), Table 1, Cl.5.2.1.7(Migration of certain elements - Antimony) |
- |
0 |
|
- |
| Sl. No. i), Table 1, Cl.5.2.1.7(Migration of certain elements - Arsenic) |
- |
0 |
|
- |
| Sl. No. i), Table 1, Cl.5.2.1.7(Migration of certain elements - Chromium) |
- |
0 |
|
- |
| Sl. No. i), Table 1, Cl.5.2.1.7(Migration of certain elements - Mercury) |
- |
0 |
|
- |
| 4.1(Material Identification, Bisphenol A,) |
- |
0 |
|
- |
| 4.2(Rubber Teats for Feeding bottle shall conform to IS 3565 (Workmanship and Finish, Acetone Extract, Free sulphur in Acetone Extract, Change in Physical property, Properties of Water Extract, pH of the Water Extract, Tension Set )) |
- |
0 |
|
- |
| 5.1.1(Description, Design, shape & dimensions) |
- |
0 |
|
- |
| 5.3.1(Environmental Stress Crack Resistance,) |
- |
0 |
|
- |
| Clauses 5.3.9.2 and 5.3.9.3,Table 3, S.no.(ix)(Phthalic acid, bis(2-ethylhexyl)ester (DEHP)-ISO 18856) |
- |
0 |
|
- |
| Sl. No. i), Table 1, Cl.5.2.1.7(Migration of certain elements - Cadmium) |
- |
0 |
|
- |
| Sl. No. i), Table 1, Cl.5.2.1.7(Migration of certain elements - Lead) |
- |
0 |
|
- |
| Sl. No. i), Table 1, Cl.5.2.1.7(Migration of certain elements - Barium) |
- |
0 |
|
- |
| Sl. No. i), Table 1, Cl.5.2.1.7(Migration of certain elements - Selenium) |
- |
0 |
|
- |
| Cl 5.1.4.2 (a)(Test for permanency of Pigment) |
- |
0 |
|
- |
| 5.3.8 a)(Migration Test a) Distilled water at 40±2° hrs) |
- |
0 |
|
- |
| 5.3.8 b)(Migration Test b) n-Haptane at 38±1° C for 30 min) |
- |
0 |
|
- |
| 5.1.2(Manufacture, workmanship finish & appearance) |
- |
0 |
|
- |
| Clause 5.3.1(Environmental Stress crack resistance) |
- |
0 |
|
- |
| Clause 5.1.4.2(Capacity Scale) |
- |
0 |
|
- |
| Clause 5.1.2.2(Workmanship.Finish and Appearance) |
- |
0 |
|
- |
| Clause 5.1.1 (Description) |
- |
0 |
|
- |
| Clause 4.2 (Teats) |
- |
0 |
|
- |
| Cl 5.3.7(Product Resistance of Printed Containers) |
- |
0 |
|
- |
| Cl 5.3.6(Compressive Deformation Resistance) |
- |
0 |
|
- |
| Cl 5.3.5(Ageing Resistance) |
- |
0 |
|
- |
| Cl 5.3.4(Drop Test) |
- |
0 |
|
- |
| Cl 5.3.3(Leakage Test) |
- |
0 |
|
- |
| Cl 5.3.2(Transparecy) |
- |
0 |
|
- |
| Cl 5.1.4(Capacity) |
- |
0 |
|
- |
| Cl 5.1.3(Wall Thickness at Top, Middle & Bottom ( Take every position 4 measurment and average will be reported)) |
- |
0 |
|
- |
| Cl 5.1(Physical Requirements) |
- |
0 |
|
- |
| "IS 14625:2015 RA2020 Sub-clause 4.0 "(Material Identification) |
- |
0 |
|
- |
| Cl 5.1(Physical Requirements) |
- |
0 |
|
- |
| Cl 5.1.3(Wall Thickness) |
- |
0 |
|
- |
| Cl 5.1.4(Capacity) |
- |
0 |
|
- |
| Cl 5.3.2(Transparecy) |
- |
0 |
|
- |
| Cl 5.3.3(Leakage Test) |
- |
0 |
|
- |
| Cl 5.3.4(Drop Test) |
- |
0 |
|
- |
| Cl 5.3.5(Ageing Resistance) |
- |
0 |
|
- |
| Cl 5.3.6(Compressive Deformation Resistance) |
- |
0 |
|
- |
| Cl 5.3.7(Product Resistance of Printed Containers) |
- |
0 |
|
- |
| "IS 14625:2015 RA2020 Sub-clause 4.0 "(Material Identification) |
- |
0 |
|
- |
| Cl.5.2.1.7, Table-1(i)(Migration of certain elements, Reqiurement as per table 1, Arsenic) |
- |
0 |
|
- |
| Cl.5.2.1.7, Table-1(ii)(Migration of certain elements, Reqiurement as per table 1, Chromium) |
- |
0 |
|
- |
| Cl.5.2.1.7, Table-1(iii)(Migration of certain elements, Reqiurement as per table 1, Mercury) |
- |
0 |
|
- |
| Cl.5.2.1.7, Table-1(iv)(Migration of certain elements, Reqiurement as per table 1, Cadmium) |
- |
0 |
|
- |
| Cl.5.2.1.7, Table-1(v)(Migration of certain elements, Reqiurement as per table 1, Lead) |
- |
0 |
|
- |
| Cl.5.2.1.7, Table-1(vi)(Migration of certain elements, Reqiurement as per table 1, Barium) |
- |
0 |
|
- |
| Cl.5.2.1.7, Table-1(vii)(Migration of certain elements, Reqiurement as per table 1, Selenium) |
- |
0 |
|
- |
| Cl.5.3.8(Migration test a)Distilled water) |
- |
0 |
|
- |
| Cl.5.3.8(Migration test a)n-Heptane) |
- |
0 |
|
- |
| Cl.5.3.9.2, Table-3(i)(Specific migration , Barium) |
- |
0 |
|
- |
| Cl.5.3.9.2, Table-3(ii)(Specific migration , Cobalt) |
- |
0 |
|
- |
| Cl.5.3.9.2, Table-3(iii)(Specific migration , Copper) |
- |
0 |
|
- |
| Cl.5.3.9.2, Table-3(iv)(Specific migration , Iron) |
- |
0 |
|
- |
| Cl.5.3.9.2, Table-3(v)(Specific migration , Lithium) |
- |
0 |
|
- |
| Cl.5.3.9.2, Table-3(vi)(Specific migration , Manganese) |
- |
0 |
|
- |
| Cl.5.3.9.2, Table-3(vii)(Specific migration , Zinc) |
- |
0 |
|
- |
| Cl.5.3.9.2, Table-3(viii)(Specific migration , Antimony) |
- |
0 |
|
- |
| Clause 5.2.1.7, S.No.(i)(Heavy metal,Antimony) |
- |
0 |
|
- |
| Clause 5.2.1.7, S.No.(ii)(Heavy metal,Arsenic) |
- |
0 |
|
- |
| Clause 5.2.1.7, S.No.(iii)(Heavy metal,Chromium) |
- |
0 |
|
- |
| Clause 5.2.1.7, S.No.(iv)(Heavy metal,Mercury) |
- |
0 |
|
- |
| Clause 5.2.1.7, S.No.(v)(Heavy metal,Cadmium) |
- |
0 |
|
- |
| Clause 5.2.1.7, S.No.(vi)(Heavy metal,Lead) |
- |
0 |
|
- |
| Clause 5.2.1.7, S.No.(vii)(Heavy metal,Barium) |
- |
0 |
|
- |
| Clause 5.2.1.7, S.No.(viii)(Heavy metal,Selenium) |
- |
0 |
|
- |
| Cl-5.2.1.2.2(pH meter) |
- |
0 |
|
- |
| Cl-5.2.1.2.3(Membrane filter) |
- |
0 |
|
- |
| Cl-5.2.1.2.4(Centrifuge) |
- |
0 |
|
- |
| Cl-5.2.1.3(Reagents) |
- |
0 |
|
- |
| Cl-5.2.1.3.1(Hydrochloric acid solution) |
- |
0 |
|
- |
| Cl-5.2.1.3.2(Hydrochloric acid solution) |
- |
0 |
|
- |
| Cl-7(Packing and Marking) |
- |
0 |
|
- |
|
25 Feb, 2027 |
- Included w.e.f 11.07.2025 |
| 4698 |
JBS TESTING SOLUTIONS PVT LTD (27), JALANDHAR
| 9164606
| IS 2415 (2015) |
Cycle - Rubber tubes (Moulded/ Jointed) - Specification (Fourth Revision) |
- |
14250 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4.1, Table 1(Classification and Designation) |
- |
14250 |
|
For complete testing |
| 5.1,3.4, Annex A & Table 2.( Flat Length ) |
- |
14250 |
|
For complete testing |
| 5.1,3.5, Annex A & Table 2.(Flat Width) |
- |
14250 |
|
For complete testing |
| 5.2, Annex A(Thickness) |
- |
14250 |
|
For complete testing |
| 5.2.1(Uniformity of Thickness) |
- |
14250 |
|
For complete testing |
| 6.1,Table 3(i)Tensile strength:) |
- |
14250 |
|
For complete testing |
| 6.1,Table 3(ii)Elongation at break ) |
- |
14250 |
|
For complete testing |
| 6.2(iii)Tension set: ) |
- |
14250 |
|
For complete testing |
| 6.3 (a)( Ageing Test:- Tensile strength :) |
- |
14250 |
|
For complete testing |
| 6.3(b)( Ageing Test :- Elongation at break) |
- |
14250 |
|
For complete testing |
| 6.4.1(Joint Adhesion Strength) |
- |
14250 |
|
For complete testing |
| 6.4.3( Strength of splice on moulded tube) |
- |
14250 |
|
For complete testing |
| 6.5(Leak Test) |
- |
14250 |
|
For complete testing |
| 6.6(Valve Test) |
- |
14250 |
|
For complete testing |
| 6.7.1(Manufacture and Workmanship) |
- |
14250 |
|
For complete testing |
| 6.7.2(Manufacture and Workmanship) |
- |
14250 |
|
For complete testing |
| 6.7.3(Manufacture and Workmanship) |
- |
14250 |
|
For complete testing |
| 6.7.4(Manufacture and Workmanship) |
- |
14250 |
|
For complete testing |
| 7.1(MARKING) |
- |
14250 |
|
For complete testing |
| 7.1(MARKING) |
- |
14250 |
|
For complete testing |
|
- |
- Included w.e.f 30.05.2025 |
| 4699 |
JBS TESTING SOLUTIONS PVT LTD (27), JALANDHAR
| 9164606
| IS 16172 (2023) |
Reinforcement Couplers for Mechanical Splices of Steel Bars in Concrete ? Specification (first revision) |
- |
17500 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 5(Classification) |
- |
7500 |
|
For dimensional and other qualitative tests |
| 6(Manufacture) |
- |
7500 |
|
For dimensional and other qualitative tests |
| 7(Workmanship and Finish) |
- |
7500 |
|
For dimensional and other qualitative tests |
| 8(Nominal Sizes) |
- |
7500 |
|
For dimensional and other qualitative tests |
| 9.2.1(Tensile Strength) |
- |
10000 |
|
For mechanical tests |
| 9.2.1.1(Disengagement test for threaded couplers) |
- |
10000 |
|
For mechanical tests |
| 9.2.2(Percentage Elongation) |
- |
10000 |
|
For mechanical tests |
| 9.3(Slip Test) |
- |
10000 |
|
For mechanical tests |
| 9.4(Cyclic Tensile Test) |
- |
10000 |
|
For mechanical tests |
| 9.5.1(Low cycle Fatigue Test) |
- |
10000 |
|
For mechanical tests |
| 9.5.2(High Cycle Fatigue test) |
- |
10000 |
|
For mechanical tests |
| 5(Classification) |
- |
0 |
|
- |
| 6(Manufacture) |
- |
0 |
|
- |
| 7(Workmanship and Finish) |
- |
0 |
|
- |
| 8(Nominal Sizes) |
- |
0 |
|
- |
| 9.2.1(Tensile Strength) |
- |
0 |
|
- |
| 9.2.1.1(Disengagement test for threaded couplers) |
- |
0 |
|
- |
| 9.2.2(Percentage Elongation) |
- |
0 |
|
- |
| 9.3(Slip Test) |
- |
0 |
|
- |
| 9.4(Cyclic Tensile Test) |
- |
0 |
|
- |
| 9.5.1(Low cycle Fatigue Test) |
- |
0 |
|
- |
| 9.5.2(High Cycle Fatigue test) |
- |
0 |
|
- |
|
- |
- Included w.e.f.10.06.2025
Exclusion
Cl 9.4 (Cyclic Tensile Test)
Cl 9.5.1 (Low cycle Fatigue Test)
Cl 9.5.2 (High Cycle Fatigue test) |
| 4700 |
Bharat Test House Pvt. Ltd. 1668 Sonipat
| 9168306
| IS 18340 (2023) |
Vinyl Sulphone - Specification |
- |
30000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl-3.1(Description) |
- |
500 |
|
- |
| Cl-3.2, Table-1 (i)(Assay (by nitrite value), percent by mass (on dry basis), Min) |
- |
5000 |
|
- |
| Cl-3.2, Table-1 (i)(Assay (by HPLC1)), percent area (on dry basis),Min) |
- |
8000 |
|
- |
| Cl-3.2, Table-1 (ii)(Hydrolysis value, percent by mass (on 100 percent basis), Min) |
- |
8000 |
|
- |
| Cl-3.2, Table-1 (iii)(Matter insoluble in sodium carbonate solution percent by mass, Max) |
- |
8000 |
|
- |
| Cl-3.2, Table-1 (iv)(4-Chloroaniline content, percent by mass (on 100 percent basis), Max) |
- |
8000 |
|
- |
| Cl-4.2(Marking) |
- |
500 |
|
- |
| Cl-3.1(Description) |
- |
0 |
|
- |
| Cl-3.2, Table-1 (i)(Assay (by nitrite value), percent by mass (on dry basis), Min) |
- |
0 |
|
- |
| Cl-3.2, Table-1 (i)(Assay (by HPLC1)), percent area (on dry basis),Min) |
- |
0 |
|
- |
| Cl-3.2, Table-1 (ii)(Hydrolysis value, percent by mass (on 100 percent basis), Min) |
- |
0 |
|
- |
| Cl-3.2, Table-1 (iii)(Matter insoluble in sodium carbonate solution percent by mass, Max) |
- |
0 |
|
- |
| Cl-3.2, Table-1 (iv)(4-Chloroaniline content, percent by mass (on 100 percent basis), Max) |
- |
0 |
|
- |
| Cl-4.2(Marking) |
- |
0 |
|
- |
|
- |
- Included w.e.f.12.09.2025 |
| 4701 |
ATCC TEST LABS LLP
| 8172626
| IS 4250 (2025) |
Electric Food-Mixers (Liquidizers and Grinders) and Centrifugal Juicers � Specification ( Second Revision ) |
- |
35000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl-4(General Requirements) |
- |
1000 |
|
- |
| Cl-5(General Conditions for the tests) |
- |
1000 |
|
- |
| Cl-6(Classification) |
- |
1000 |
|
- |
| Cl-7(Marking) |
- |
1000 |
|
- |
| Cl-8(Safety Requirements) |
- |
7000 |
|
- |
| Cl-9(Endurance fpr motor and base assembly) |
- |
1000 |
|
- |
| Cl-10.2("Grinding Coffee (for Machines that Have a
Dry Grinding Arrangement)") |
- |
1000 |
|
- |
| Cl-10.3(Whisking Egg Whites (for Machines that have Whisking Egg Arrangement)) |
- |
1000 |
|
- |
| Cl-10.4(Idli Batter) |
- |
1000 |
|
- |
| Cl-10.5(Operational Tests for Juicers) |
- |
2000 |
|
- |
| Cl-11(Temperature Withstand Test for Bowl) |
- |
1000 |
|
- |
| Cl-12.1(Test for Switches) |
- |
2000 |
|
- |
| Cl-13(Strength of Assembly) |
- |
3000 |
|
- |
| Cl-14.2, 14.3 Table-2 (i)(Protection against access to live parts) |
- |
2000 |
|
- |
| Cl-14.2, Table-2 (ii)(Power input and current) |
- |
3000 |
|
- |
| Cl-14.2, 14.3 Table-2 (iii)(Leakage current and electric strength at operating temperature) |
- |
2000 |
|
- |
| Cl-14.2, Table-2 (iv)(Moisture resistance) |
- |
2000 |
|
- |
| Cl-14.2, Table-2 (v)(Leakage current and electric strength) |
- |
2000 |
|
- |
| Cl-14.2, 14.3 Table-2 (vi)(Provision for earthing) |
- |
1000 |
|
- |
|
- |
- Included w.e.f 14.08.2025
Exclusion: Cl-19.11.4.1-Cl-19.11.4.7 (EMI/EMC) |
| 4702 |
S.B.Steels Company, Bally
| 5120906
| IS 9295 (2024) |
STEEL TUBES FOR IDLERS FOR BELT CONVEYORS - SPECIFICATION (second revision) |
- |
10000.00 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| As per clause 7.1.5(Sulphur) |
- |
500.00 |
|
- |
| As per clause 7.1.6(Phosphorus) |
- |
500.00 |
|
- |
| As per clause 8.1(Tensile Test) |
- |
500.00 |
|
- |
| As per clause 8.1.1(Yield Stress) |
- |
500.00 |
|
- |
| As per clause 8.1.2(Elongation) |
- |
500.00 |
|
- |
| As per clause 8.2(Drift Expansion Test) |
- |
500.00 |
|
- |
| As per clause 8.3(Flattening Test) |
- |
500.00 |
|
- |
| Cl-9.1, Table-2(Outside Diameter) |
- |
500.00 |
|
- |
| As per clause 10(Hardness Test) |
- |
500.00 |
|
- |
| As per clause 13(Dimension Tolerance) |
- |
2000.00 |
|
- |
| As per clause 14(Workmanship) |
- |
500.00 |
|
- |
| As per clause 15(Straightness) |
- |
500.00 |
|
- |
| As per clause 16(Length) |
- |
500.00 |
|
- |
| As per clause 17(Surface Protection) |
- |
500.00 |
|
- |
| As per Clause 5(Types /Grade and Designation) |
- |
500.00 |
|
- |
| As per clause 7.1.5(Sulphur) |
- |
500.00 |
|
- |
| As per clause 7.1.6(Phosphorus) |
- |
500.00 |
|
- |
| As per clause 8.1(Tensile Test) |
- |
1000.00 |
|
- |
| As per clause 8.1.1(Yield Stress) |
- |
1000.00 |
|
- |
| As per clause 8.1.2(Elongation) |
- |
1000.00 |
|
- |
| As per clause 8.2(Drift Expansion Test) |
- |
500.00 |
|
- |
| As per clause 8.3(Flattening Test) |
- |
500.00 |
|
- |
| Cl-9.1, Table-2(Outside Diameter) |
- |
500.00 |
|
- |
| As per clause 10(Hardness Test) |
- |
500.00 |
|
- |
| As per clause 13(Dimension Tolerance) |
- |
2000.00 |
|
- |
| As per clause 14(Workmanship) |
- |
500.00 |
|
- |
| As per clause 15(Straightness) |
- |
500.00 |
|
- |
| As per clause 16(Length) |
- |
500.00 |
|
- |
| As per clause 17(Surface Protection) |
- |
500.00 |
|
- |
| As per Clause 5(Types /Grade and Designation) |
- |
500.00 |
|
- |
| Cl-9.1, Table-2(Thickness) |
- |
500.00 |
|
- |
| Cl-9.1, Table-2(Mass) |
- |
500.00 |
|
- |
|
06 Sep, 2027 |
- Included w.e.f 03.06.2025 |
| 4703 |
Sleen India Biz venture Private Limited, Agra
| 9139736
| IS 8698 (2022) |
expanded vinyl coated fabrics-Specification Second Revision |
Type A and Type B |
16000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl-7.1(Description) |
- |
500 |
|
- |
| Cl-7.2(Base Fabric) |
- |
500 |
|
- |
| Cl-7.3(Appearance) |
- |
500 |
|
- |
| Cl-7.4(Colour, Grain and Finish) |
- |
500 |
|
- |
| Cl-7.5(Coating) |
- |
500 |
|
- |
| Cl-7.6(Resistance to Heat and Loss of Mass on Heating) |
- |
1000 |
|
- |
| Cl-7.7(Resistance to Cold) |
- |
1000 |
|
- |
| Cl-7.8(Colour Fastness to Dry and Wet Rubbing) |
- |
500 |
|
- |
| Cl-7.9(Colour Fastness to Light) |
- |
500 |
|
- |
| Cl-7.10(Gelling Test) |
- |
500 |
|
- |
| Cl-7.11(Adhesion of Print) |
- |
500 |
|
- |
| Cl-7.12(Flame Resistance) |
- |
1000 |
|
- |
| Cl-7.13(Adhesion of Coating) |
- |
1000 |
|
- |
| Cl-7.14(Blocking Resistance) |
- |
1000 |
|
- |
| Cl-7.15(Resistance to Penetration of Water) |
- |
1000 |
|
- |
| Cl-7.16("Elongation and Elastic Recovery for a Constant
Load") |
- |
1000 |
|
- |
| Cl-7.17, 8.1 Table-1 (i)(Usable width, Min, cm) |
- |
500 |
|
- |
| Cl-7.17, 8.1 Table-1 (ii)(Mass of finished fabric, Min, g/m2) |
- |
500 |
|
- |
| Cl-7.17, 8.1 Table-1 (iii)(a) Longitudinal direction) |
- |
1000 |
|
- |
| Cl-7.17, 8.1 Table-1 (iii)(b) Transverse direction) |
- |
0 |
|
Breaking strength test price is 1000/-. |
| Cl-7.17, 8.1 Table-1 (iv)(Tear strength) |
- |
1000 |
|
- |
| Cl-7.17, 8.1 Table-1 (v)(Resistance to damage by flexing) |
- |
500 |
|
- |
| Cl-8.2(Test Specimens) |
- |
300 |
|
- |
| Cl-9.2(Marking) |
- |
200 |
|
- |
| Cl-7.1(Description) |
- |
0 |
|
- |
| Cl-7.2(Base Fabric) |
- |
0 |
|
- |
| Cl-7.3(Appearance) |
- |
0 |
|
- |
| Cl-7.4(Colour, Grain and Finish) |
- |
0 |
|
- |
| Cl-7.5(Coating) |
- |
0 |
|
- |
| Cl-7.6(Resistance to Heat and Loss of Mass on Heating) |
- |
0 |
|
- |
| Cl-7.7(Resistance to Cold) |
- |
0 |
|
- |
| Cl-7.8(Colour Fastness to Dry and Wet Rubbing) |
- |
0 |
|
- |
| Cl-7.9(Colour Fastness to Light) |
- |
0 |
|
- |
| Cl-7.10(Gelling Test) |
- |
0 |
|
- |
| Cl-7.11(Adhesion of Print) |
- |
0 |
|
- |
| Cl-7.12(Flame Resistance) |
- |
0 |
|
- |
| Cl-7.13(Adhesion of Coating) |
- |
0 |
|
- |
| Cl-7.14(Blocking Resistance) |
- |
0 |
|
- |
| Cl-7.15(Resistance to Penetration of Water) |
- |
0 |
|
- |
| Cl-7.16("Elongation and Elastic Recovery for a Constant
Load") |
- |
0 |
|
- |
| Cl-7.17, 8.1 Table-1 (i)(Usable width, Min, cm) |
- |
0 |
|
- |
| Cl-7.17, 8.1 Table-1 (ii)(Mass of finished fabric, Min, g/m2) |
- |
0 |
|
- |
| Cl-7.17, 8.1 Table-1 (iii)(a) Longitudinal direction) |
- |
0 |
|
- |
| Cl-7.17, 8.1 Table-1 (iii)(b) Transverse direction) |
- |
0 |
|
- |
| Cl-7.17, 8.1 Table-1 (iv)(Tear strength) |
- |
0 |
|
- |
| Cl-7.17, 8.1 Table-1 (v)(Resistance to damage by flexing) |
- |
0 |
|
- |
| Cl-8.2(Test Specimens) |
- |
0 |
|
- |
| Cl-9.2(Marking) |
- |
0 |
|
- |
| Cl-7.1(Description) |
- |
0 |
|
- |
| Cl-7.2(Base Fabric) |
- |
0 |
|
- |
| Cl-7.3(Appearance) |
- |
0 |
|
- |
| Cl-7.4(Colour, Grain and Finish) |
- |
0 |
|
- |
| Cl-7.5(Coating) |
- |
0 |
|
- |
| Cl-7.6(Resistance to Heat and Loss of Mass on Heating) |
- |
0 |
|
- |
| Cl-7.7(Resistance to Cold) |
- |
0 |
|
- |
| Cl-7.8(Colour Fastness to Dry and Wet Rubbing) |
- |
0 |
|
- |
| Cl-7.9(Colour Fastness to Light) |
- |
0 |
|
- |
| Cl-7.10(Gelling Test) |
- |
0 |
|
- |
| Cl-7.11(Adhesion of Print) |
- |
0 |
|
- |
| Cl-7.12(Flame Resistance) |
- |
0 |
|
- |
| Cl-7.13(Adhesion of Coating) |
- |
0 |
|
- |
| Cl-7.14(Blocking Resistance) |
- |
0 |
|
- |
| Cl-7.15(Resistance to Penetration of Water) |
- |
0 |
|
- |
| Cl-7.16("Elongation and Elastic Recovery for a Constant
Load") |
- |
0 |
|
- |
| Cl-7.17, 8.1 Table-1 (i)(Usable width, Min, cm) |
- |
0 |
|
- |
| Cl-7.17, 8.1 Table-1 (ii)(Mass of finished fabric, Min, g/m2) |
- |
0 |
|
- |
| Cl-7.17, 8.1 Table-1 (iii)(a) Longitudinal direction) |
- |
0 |
|
- |
| Cl-7.17, 8.1 Table-1 (iii)(b) Transverse direction) |
- |
0 |
|
- |
| Cl-7.17, 8.1 Table-1 (iv)(Tear strength) |
- |
0 |
|
- |
| Cl-7.17, 8.1 Table-1 (v)(Resistance to damage by flexing) |
- |
0 |
|
- |
| Cl-8.2(Test Specimens) |
- |
0 |
|
- |
| Cl-9.2(Marking) |
- |
0 |
|
- |
|
- |
- Included w.e.f.23.06.2025 |
| 4704 |
ALPHA TEST HOUSE PVT LTD, BAHADURGARH
| 8185306
| IS 302 : Part 2 : Sec 25 (2014) |
Safety of household and similar electrical appliances: Part 2 Particular requirements: Section 25 Microwave ovens |
- |
225000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 6.0(Classification) |
- |
45000 |
|
Extra EMI/EMC charges: 1,80,000 |
| 7(Marking and instructions) |
- |
45000 |
|
Extra EMI/EMC charges: 1,80,000 |
| 8(Protection against live parts) |
- |
45000 |
|
Extra EMI/EMC charges: 1,80,000 |
| 10(POWER INPUT AND CURRENT) |
- |
45000 |
|
Extra EMI/EMC charges: 1,80,000 |
| 11(HEATING) |
- |
45000 |
|
Extra EMI/EMC charges: 1,80,000 |
| 13(LEAKAGE CURRENT AND ELECTRIC STRENGTH AT OPERATING TEMPERATURE) |
- |
45000 |
|
Extra EMI/EMC charges: 1,80,000 |
| 14(IMPULSE VOLTAGE TEST) |
- |
45000 |
|
Extra EMI/EMC charges: 1,80,000 |
| 15(HUMIDITY TREATMENT TEST) |
- |
45000 |
|
Extra EMI/EMC charges: 1,80,000 |
| 16(LEAKAGE CURRENT AND ELECTRIC STRENGTH) |
- |
45000 |
|
Extra EMI/EMC charges: 1,80,000 |
| 17(OVERLOAD PROTECTION OF TRANSFORMERS AND ASSOCIATED CIRCUITS) |
- |
45000 |
|
Extra EMI/EMC charges: 1,80,000 |
| 19(ABNORMAL OPERATION) |
- |
45000 |
|
Extra EMI/EMC charges: 1,80,000 |
| 20(STABILITY AND MECHANICAL HAZARDS) |
- |
45000 |
|
Extra EMI/EMC charges: 1,80,000 |
| 21(MECHANICAL STRENGTH) |
- |
45000 |
|
Extra EMI/EMC charges: 1,80,000 |
| 22(CONSTRUCTION) |
- |
45000 |
|
Extra EMI/EMC charges: 1,80,000 |
| 23(INTERNAL WIRING) |
- |
45000 |
|
Extra EMI/EMC charges: 1,80,000 |
| 24(COMPONENTS) |
- |
45000 |
|
Extra EMI/EMC charges: 1,80,000 |
| 25(SUPPLY CONNECTION AND EXTERNAL FLEXIBLE CORDS) |
- |
45000 |
|
Extra EMI/EMC charges: 1,80,000 |
| 26(TERMINALS FOR EXTERNAL CONDUCTORS) |
- |
45000 |
|
Extra EMI/EMC charges: 1,80,000 |
| 27(PROVISION FOR EARTHING) |
- |
45000 |
|
Extra EMI/EMC charges: 1,80,000 |
| 28(SCREWS AND CONNECTIONS) |
- |
45000 |
|
Extra EMI/EMC charges: 1,80,000 |
| 29(CLEARANCES, CREEPAGE DISTANCES AND SOLID INSULATION) |
- |
45000 |
|
Extra EMI/EMC charges: 1,80,000 |
| 30(RESISTANCE TO HEAT AND FIRE) |
- |
45000 |
|
Extra EMI/EMC charges: 1,80,000 |
| 31(RESISTANCE TO RUSTING) |
- |
45000 |
|
Extra EMI/EMC charges: 1,80,000 |
| 32(RADIATION, TOXICITY AND SIMILAR HAZARDS) |
- |
45000 |
|
Extra EMI/EMC charges: 1,80,000 |
| Cl-19.11.4.1(Electrostatic discharge) |
- |
180000 |
|
- |
| Cl-19.11.4.2(Radiated Fields) |
- |
180000 |
|
- |
| Cl-19.11.4.5(Immunity to conducted discharge) |
- |
180000 |
|
- |
| Cl-19.11.4.3(Fast transient bursts) |
- |
180000 |
|
- |
| Cl-19.11.4.4(Surge Immunity test) |
- |
180000 |
|
- |
| Cl-19.11.4.6(Voltage dips and interruptions) |
- |
180000 |
|
- |
| Cl-19.11.4.7(Harmonics) |
- |
180000 |
|
- |
| 18(ENDURANCE) |
- |
45000 |
|
Extra EMI/EMC charges: 1,80,000 |
| 9(STARTING OF MOTOR-OPERATED APPLIANCES) |
- |
0 |
|
- |
| 22.32(Oxygen bomb for rubber material) |
- |
45000 |
|
Extra EMI/EMC charges: 1,80,000 |
| 22.46(Software) |
- |
45000 |
|
Extra EMI/EMC charges: 1,80,000 |
|
08 May, 2028 |
- Included w.e.f.19.06.2025 |
| 4705 |
WELL TECH TEST AND RESEARCH CENTER, DERABASSI
| 9177306
| IS 15997 (2012) |
Low nickel austenitic stainless steel sheet and strip for utensils and kitchen appliances - Specification |
TABLE 1 DIM AS PER TABLE 5 TO12 |
12500 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl. 8.1, 8.1.1 & 10.1 Table 1(Carbon -IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
1000 |
|
- |
| Cl. 8.1, 8.1.1 & 10.1 Table 1(Silicon -IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
1000 |
|
- |
| Cl. 8.1, 8.1.1 & 10.1 Table 1(Manganese -IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
1000 |
|
- |
| Cl. 8.1, 8.1.1 & 10.1 Table 1(Nickel -IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
1000 |
|
- |
| Cl. 8.1, 8.1.1 & 10.1 Table 1(Chromium -IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
1000 |
|
- |
| Cl. 8.1, 8.1.1 & 10.1 Table 1(Sulphur -IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
1000 |
|
- |
| Cl. 8.1, 8.1.1 & 10.1 Table 1(Phosphorus -IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
1000 |
|
- |
| Cl. 8.1, 8.1.1 & 10.1 Table 1(Copper -IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
1000 |
|
- |
| Cl. 8.1, 8.1.1 & 10.1 Table 1(Nitrogen -IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
1000 |
|
- |
| 6(Freedom From Defects) |
- |
500 |
|
- |
| 9.3(Tensile Test-1608:Part 1) |
- |
2000 |
|
- |
| 9.3, Table 3 (Yield Strength, Mpa) |
- |
2000 |
|
- |
| 9.3, Table 3 (Tensile Strength, Mpa) |
- |
1500 |
|
- |
| 9.3, Table 3 (Elongation, %) |
- |
1000 |
|
- |
| 9.4(Erichsen Cupping Test,(Average depth of cupping) mm) |
- |
2000 |
|
- |
| 11(Surface finish) |
- |
1000 |
|
- |
| 12(Dimensions) |
- |
2500 |
|
- |
| 14.1(Thickness,mm) |
- |
1000 |
|
- |
| 14.2( Width, mm) |
- |
1000 |
|
- |
| 14.3(Length, mm) |
- |
500 |
|
- |
| 14.4(Flatness, mm) |
- |
1000 |
|
- |
| 14.5(Camber, mm) |
- |
1000 |
|
- |
| Clause 9.1, 9.2 & Table 3(IS 1608 Part 1) |
- |
0 |
|
REPEATED CLAUSE |
| 17(Marking) |
- |
500 |
|
- |
| Clause 9.1, 9.2 & Table 3(0.2 Percent Yield Strength) |
- |
0 |
|
REPEATED CLAUSE |
| 4.1(General requirements) |
- |
0 |
|
REPEATED CLAUSE |
| 6(Freedom from defects) |
- |
0 |
|
REPEATED CLAUSE |
| 7(Heat treatment) |
- |
100 |
|
- |
| 8.1, table 1(C
Si
Mn
Ni
Cr
S
P
Cu
Ni) |
- |
0 |
|
REPEATED CLAUSE |
| 9.1(Sample plan) |
- |
0 |
|
REPEATED CLAUSE |
| 9.2(Tensile test) |
- |
0 |
|
REPEATED CLAUSE |
| 9.3(Mechanical properties) |
- |
0 |
|
REPEATED CLAUSE |
| 9.4(Erichsen cupping test) |
- |
0 |
|
REPEATED CLAUSE |
| 10(Retests) |
- |
0 |
|
REPEATED CLAUSE |
| 11(Surface finish) |
- |
0 |
|
REPEATED CLAUSE |
| 12(Dimensions) |
- |
0 |
|
REPEATED CLAUSE |
| 13(Edge condition) |
- |
500 |
|
- |
| 14.1(Thickness) |
- |
0 |
|
REPEATED CLAUSE |
| 14.2.1(Mill Edge) |
- |
500 |
|
- |
| 14.2.2(Trimmed Edge) |
- |
500 |
|
- |
| 8.1.1, table 2(Carbon
Silicon
Manganese
Nickel
Chromium
Sulphur
Phosphorus
Copper
Nitrogen) |
- |
0 |
|
REPEATED CLAUSE |
| 14.3(Length) |
- |
0 |
|
REPEATED CLAUSE |
| 14.4(Flatness) |
- |
0 |
|
REPEATED CLAUSE |
| 14.5(Camber) |
- |
0 |
|
REPEATED CLAUSE |
| 15(Inspection) |
- |
0 |
|
REPEATED CLAUSE |
| 17(Marking) |
- |
0 |
|
REPEATED CLAUSE |
|
30 Mar, 2027 |
- Included w.e.f 30.05.2025 |
| 4706 |
Vimta Labs Limited, Bengaluru
| 6164216
| IS 14543 (2024) |
Packaged Drinking Water Other than Packaged Natural Mineral Water Specification Third Revision |
- |
32900 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl-5.2.1(Escherichia coli or thermotolerant bacteria) |
- |
350 |
|
- |
| Cl-5.2.2(Coliform) |
- |
300 |
|
- |
| Cl-5.2.3(Staphylococcus aureus) |
- |
600 |
|
- |
| Cl-5.2.4(Sulphite Reducing Anaerobes) |
- |
500 |
|
- |
| Cl-5.2.5(Pseudomonas Aeruginosa) |
- |
500 |
|
- |
| Cl-5.2.6(Aerobic Microbial Count @ 37 deg C) |
- |
600 |
|
- |
| Cl-5.2.7(Yeast and mould) |
- |
300 |
|
- |
| Cl-5.2.8(Salmonella) |
- |
600 |
|
- |
| Cl-5.2.9(Vibrio cholera) |
- |
600 |
|
- |
| Cl-5.2.3(Faecal streptococci) |
- |
600 |
|
- |
| Cl-5.2.8(shigella) |
- |
600 |
|
- |
| Cl-5.2.9(V.parahaemolyticus) |
- |
600 |
|
- |
| 5.2.6(Aerobic Microbial Count @ 20 to 22 deg C) |
- |
600 |
|
- |
| Cl-5.3, Table-1 (i)(Colour, true colour units, Max) |
- |
300 |
|
- |
| Cl-5.3, Table-1 (ii)(Odour) |
- |
100 |
|
- |
| Cl-5.3, Table-1 (iii)(Taste) |
- |
100 |
|
- |
| Cl-5.3, Table-1 (iv)(Turbidity, nephelometric turbidity unit (NTU), Max) |
- |
300 |
|
- |
| Cl-5.3, Table-1 (v)(Total dissolved solids, mg/l, Max) |
- |
300 |
|
- |
| Cl-5.3, Table-1 (vi)(pH) |
- |
300 |
|
- |
| Cl-5.3, Table-2 (i)(Barium (as Ba)) |
- |
500 |
|
- |
| Cl-5.3, Table-2 (ii)(Copper (as Cu)) |
- |
500 |
|
- |
| Cl-5.3, Table-2 (iii)(Iron (as Fe)) |
- |
500 |
|
- |
| Cl-5.3, Table-2 (iv)(Manganese (as Mn)) |
- |
500 |
|
- |
| Cl-5.3, Table-2 (v)(Nitrate (as NO3 )) |
- |
400 |
|
- |
| Cl-5.3, Table-2 (vi)(Nitrite (as NO2 )) |
- |
400 |
|
- |
| Cl-5.3, Table-2 (vii)(Fluoride (as F)) |
- |
400 |
|
- |
| Cl-5.3, Table-2 (viii)(Zinc (as Zn)) |
- |
400 |
|
- |
| Cl-5.3, Table-2 (ix)(Silver (as Ag)) |
- |
500 |
|
- |
| Cl-5.3, Table-2 (x)(Aluminium (as A1)) |
- |
500 |
|
- |
| Cl-5.3, Table-2 (xi)(Chloride (as Cl)) |
- |
400 |
|
- |
| Cl-5.3, Table-2 (xii)(Selenium (as Se)) |
- |
400 |
|
- |
| Cl-5.3, Table-2 (xiii)(Sulphate (as SO4 )) |
- |
400 |
|
- |
| Cl-5.3, Table-2 (xiv)(Alkalinity (as HCO3 )) |
- |
400 |
|
- |
| Cl-5.3, Table-2 (xv)(Calcium (as Ca)) |
- |
400 |
|
- |
| Cl-5.3, Table-2 (xvi)(Magnesium (as Mg)) |
- |
400 |
|
- |
| Cl-5.3, Table-2 (xvii)(Sodium (as Na)) |
- |
400 |
|
- |
| Cl-5.3, Table-2 (xviii)(Residual free chlorine) |
- |
250 |
|
- |
| Cl-5.3, Table-2 (xix)(Phenolic compounds (as C6H5OH)) |
- |
750 |
|
- |
| Cl-5.3, Table-2 (xx)(Mineral oil) |
- |
1500 |
|
- |
| Cl-5.3, Table-2 (xxi)(Anionic surface active agents) |
- |
1500 |
|
- |
| Cl-5.3, Table-2 (xxii)(Sulphide) |
- |
750 |
|
- |
| Cl-5.3, Table-2 (xxiii)(Antimony (as Sb)) |
- |
500 |
|
- |
| Cl-5.3, Table-2 (xxiv)(Borates (as B)) |
- |
500 |
|
- |
| Cl-5.3, Table-2 (xxv)(Bromates (as BrO3 )) |
- |
500 |
|
- |
| Cl-5.3, Table-3 (i)(Mercury (as Hg)) |
- |
500 |
|
- |
| Cl-5.3, Table-3 (ii)(Cadmium (as Cd)) |
- |
500 |
|
- |
| Cl-5.3, Table-3 (iii)(Arsenic (as As)) |
- |
500 |
|
- |
| Cl-5.3, Table-3 (iv)(Cyanide (as CN)) |
- |
500 |
|
- |
| Cl-5.3, Table-3 (v)(Lead (as Pb)) |
- |
500 |
|
- |
| Cl-5.3, Table-3 (vi)(Chromium (as Cr)) |
- |
500 |
|
- |
| Cl-5.3, Table-3 (vii)(Nickel (as Ni)) |
- |
500 |
|
- |
| Cl-5.3, Table-3 (x)(Uranium) |
- |
500 |
|
- |
| Table 3, x)(Uranium) |
- |
500 |
|
- |
| 5.4/Annex D/i(P,P-DDT) |
- |
1000 |
|
- |
| 5.4/Annex D/ii(Lindane) |
- |
1000 |
|
- |
| 5.4/Annex D/iv(b-Endosulfan) |
- |
1000 |
|
- |
| 5.4/Annex D/xvi(Dieldrin) |
- |
1000 |
|
- |
| 5.4/Annex D/i(O,P-DDT) |
- |
1000 |
|
- |
| 5.4/Annex D/iv(a-Endosulfan) |
- |
1000 |
|
- |
| 5.4/Annex D/iii(d-HCH) |
- |
1000 |
|
- |
| 5.4/Annex D/i(O,P-DDD) |
- |
1000 |
|
- |
| 5.4/Annex D/i(P,P-DDE) |
- |
1000 |
|
- |
| 5.4/Annex D/i(O,P-DDE) |
- |
1000 |
|
- |
| 5.4/Annex D/iii(a-HCH) |
- |
1000 |
|
- |
| 5.4/Annex D/iii(β- HCH) |
- |
1000 |
|
- |
| 5.4/Annex D/iv(Endosulfan sulfate) |
- |
1000 |
|
- |
| 5.4/Annex D/i(P,P-DDD) |
- |
1000 |
|
- |
| 5.4/Annex D/xii(Alachlor) |
- |
1000 |
|
- |
| 5.4/Annex D/vii(Chlorpyrifos) |
- |
1000 |
|
- |
| 5.4/Annex D/x(Butachlor) |
- |
1000 |
|
- |
| 5.4/Annex D/vi(Ethion) |
- |
1000 |
|
- |
| 5.4/Annex D/xiv(Methyl parathion) |
- |
1000 |
|
- |
| 5.4/Annex D/xv(Malathion) |
- |
1000 |
|
- |
| 5.4/Annex D/viii(Phorate) |
- |
1000 |
|
- |
| 5.4/Annex D/v(Monochrotophos) |
- |
1000 |
|
- |
| 5.4/Annex D/xiii(Atrazine) |
- |
1000 |
|
- |
| 5.4/Annex D/viii(Phorate sulphoxide) |
- |
1000 |
|
- |
| 5.4/Annex D/viii(Phorate sulfone) |
- |
1000 |
|
- |
| 5.4/Annex D/xxvii(Methyl paraoxon) |
- |
1000 |
|
- |
| 5.4/Annex D/xxviii(Malaoxon) |
- |
1000 |
|
- |
| 5.4/Annex D/xi(Isoproturon) |
- |
1000 |
|
- |
| 5.4/Annex D/ix(2,4 –D) |
- |
1000 |
|
- |
| 5.4/Annex D/xvi(Aldrin) |
- |
1000 |
|
- |
| Cl-5.3, Table-3 (viii)(Polychlorinated biphenyl (PCB)) |
- |
1000 |
|
- |
| Cl-5.3, Table-3 (ix)(Polynuclear aromatic hydrocarbons) |
- |
1000 |
|
- |
| 5.3(Appearance) |
- |
200 |
|
- |
| 5.3/Table 2/xiii(Suphate) |
- |
400 |
|
- |
| 5.4 i)(Dieldrin) |
- |
1000 |
|
- |
| 5.4 i)(Aldrin) |
- |
1000 |
|
- |
| 5.4 i)(Malathion) |
- |
1000 |
|
- |
| 5.4, i)("oxygen analogue of Malathion (Malaoxon)") |
- |
1000 |
|
- |
| 5.4 i)(Methyl Paraoxon) |
- |
1000 |
|
- |
| 5.4 i)(Methyl Parathion) |
- |
1000 |
|
- |
| 5.4 i)(Atrazine) |
- |
1000 |
|
- |
| 5.4 i)(Alachlor) |
- |
1000 |
|
- |
| 5.4 i)(Isoproturon) |
- |
1000 |
|
- |
| 5.4 i)(Butachlor) |
- |
1000 |
|
- |
| 5.4 i)(2,4-D) |
- |
1000 |
|
- |
| 5.4 i)(Phorate sulphone) |
- |
1000 |
|
- |
| 5.4 i)(Phorate sulphoxide) |
- |
1000 |
|
- |
| 5.4 i)(Phorate) |
- |
1000 |
|
- |
| 5.4 i)(Chlorpyrifos) |
- |
1000 |
|
- |
| 5.4 i)(Ethion) |
- |
1000 |
|
- |
| 5.4 i)(Monocrotophos) |
- |
1000 |
|
- |
| 5.4 i)(Endosulfan Sulphate) |
- |
1000 |
|
- |
| 5.4 i)(beta-Endosulfan) |
- |
1000 |
|
- |
| 5.4 i)(alpha-Endosulfan) |
- |
1000 |
|
- |
| 5.4 i)(Delta-HCH) |
- |
1000 |
|
- |
| 5.4 i)(beta-HCH) |
- |
1000 |
|
- |
| 5.4 i)(alpha-HCH) |
- |
1000 |
|
- |
| 5.4 i)(Gamma-HCH (Lindane)) |
- |
1000 |
|
- |
| 5.4 i)(p,p DDD) |
- |
1000 |
|
- |
| 5.4 i)(o,p DDD) |
- |
1000 |
|
- |
| 5.4 i)(p,p DDE) |
- |
1000 |
|
- |
| 5.4, i)(o,p DDE) |
- |
1000 |
|
- |
| 5.4 i)(p,p DDT) |
- |
1000 |
|
- |
| 5.4 i)(o,p DDT) |
- |
1000 |
|
- |
| Cl-5.4 (i)(Pesticide residues considered individually) |
- |
6500 |
|
- |
| Cl-5.4 (ii)(Total pesticide residue) |
- |
6500 |
|
- |
| Cl-5.1(General Requirements) |
- |
15850 |
|
- |
|
15 Oct, 2025 |
- Included w.e.f 04.07.2025
Exclusion: Cl 5.3 Table 4(i) Alpha emitter (ii) Beta emitter |
| 4707 |
ALPHA TEST HOUSE PVT LTD, BAHADURGARH
| 8185306
| IS 16333 : Part 3 (2022) |
Mobile phone handsets: Part 3 Indian language support for mobile phone handsets - Specific requirements(Second Revision) |
All |
20000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 5.1(Inputting of text) |
- |
20000 |
|
- |
| 5.2(Message Readability) |
- |
20000 |
|
- |
| 6(Marking) |
- |
20000 |
|
- |
| "Cl.6.1 "(Marking) |
- |
20000 |
|
- |
| "Cl.6.2 "(BIS Certification Marking) |
- |
20000 |
|
- |
| 4(Requirements) |
- |
20000 |
|
- |
| 5(Tests) |
- |
20000 |
|
- |
| 6(Marking) |
- |
20000 |
|
- |
|
08 May, 2028 |
- Included w.e.f.30.05.2025 |
| 4708 |
JBS TESTING SOLUTIONS PVT LTD (27), JALANDHAR
| 9164606
| IS 9997 (2023) |
ALUMINIUM ALLOY REDRAW RODS FOR ELECTRICAL PURPOSES - SPECIFICATION |
- |
14800 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl-5.1(General requirements) |
- |
14800 |
|
For complete testing |
| Cl-5.2(Redraw rods) |
- |
14800 |
|
For complete testing |
| Cl-6(Manufacture) |
- |
14800 |
|
For complete testing |
| Cl-7.1, Table-2 (i)(Silicon) |
- |
14800 |
|
For complete testing |
| Cl-7.1, Table-2 (ii)(Iron) |
- |
14800 |
|
For complete testing |
| Cl-7.1, Table-2 (iii)(Copper) |
- |
14800 |
|
For complete testing |
| Cl-7.1, Table-2 (iv)(Manganese) |
- |
14800 |
|
For complete testing |
| Cl-7.1, Table-2 (v)(Magnesium) |
- |
14800 |
|
For complete testing |
| Cl-7.1, Table-2 (vi)(Chromium) |
- |
14800 |
|
For complete testing |
| Cl-7.1, Table-2 (vii)(Zinc) |
- |
14800 |
|
For complete testing |
| Cl-7.1, Table-2 (viii)(Boron) |
- |
14800 |
|
For complete testing |
| Cl-7.1, Table-2 (ix)(Vanadium + Titanium) |
- |
14800 |
|
For complete testing |
| Cl-7.1, Table-2 (x)(Other each) |
- |
14800 |
|
For complete testing |
| Cl-7.1, Table-2 (xi)(Others total) |
- |
14800 |
|
For complete testing |
| Cl-7.1, Table-2 (xii)(Aluminium) |
- |
14800 |
|
For complete testing |
| Cl-8.1, Table-3(UTS (MPa)) |
- |
14800 |
|
For complete testing |
| Cl-8.1, Table-3(Elongation (%) - On 250 mm gauge length) |
- |
14800 |
|
For complete testing |
| Cl-8.1, Table-3(Resistivity (micro ohm.cm) at 20 oC) |
- |
14800 |
|
For complete testing |
| Cl-8.1, Table-3(Conductivity (%) (IACS)) |
- |
14800 |
|
For complete testing |
| Cl-9(Electrical resistivity) |
- |
14800 |
|
For complete testing |
| Cl-10(Diameter and Permissible Variations) |
- |
14800 |
|
For complete testing |
| Cl-11(Joints) |
- |
14800 |
|
For complete testing |
| Cl-12(Finish and freedom from defects) |
- |
14800 |
|
For complete testing |
| Cl-16(Marking) |
- |
14800 |
|
For complete testing |
|
- |
- Included w.e.f 30.05.2025 |
| 4709 |
Sleen India Biz venture Private Limited, Agra
| 9139736
| IS 8699 (1977) |
Specification for pvc coated fabrics for footwear industry |
Type A/Type B |
12000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 3.1.1 and 4.1, Table - 1 (ii)(Total Mass) |
- |
500 |
|
- |
| 3.1.1 and 4.1, Table - 1 (iii)(Breaking Strength Warp direction) |
- |
1000 |
|
- |
| 3.1.1 and 4.1, Table - 1 (iii)(Breaking Strength Weft direction) |
- |
0 |
|
- |
| 3.1.1 and 4.1, Table - 1 (iv)("Resistance to damage by flexing Stage I
") |
- |
1000 |
|
- |
| 3.1.1 and 4.1, Table - 1 (iv)("Resistance to damage by flexing Stage II
") |
- |
0 |
|
- |
| 3.1.1 and 4.1, Table - 1 (v)(Thickness) |
- |
500 |
|
- |
| 4.2(Appearance) |
- |
500 |
|
- |
| 4.3(Colour , Grain, Embossing and finish) |
- |
500 |
|
- |
| 4.4.1(Resistance to cold) |
- |
1000 |
|
- |
| 4.4.2(Colour fastness to Dry and Wet Rubbing) |
- |
1000 |
|
- |
| 4.4.3(Colour fastness to light) |
- |
1000 |
|
- |
| 4.4.4(Resistance to heat and loss of mass of coating on heating) |
- |
1000 |
|
- |
| 4.4.5(Stability at Vulcanization Temperature) |
- |
1000 |
|
- |
| 4.5(Resistance to Gelling) |
- |
1000 |
|
- |
| 4.5.1(Embossing on Grain) |
- |
500 |
|
- |
| 4.6(Adhesion of print (for Printed PVC Coated fabrics)) |
- |
1000 |
|
- |
| 4.7(Adhesion of coating) |
- |
1000 |
|
- |
| 3.1.1 and 4.1, Table - 1 (ii)(Total Mass) |
- |
0 |
|
- |
| 3.1.1 and 4.1, Table - 1 (iii)(Breaking Strength Warp direction) |
- |
0 |
|
- |
| 3.1.1 and 4.1, Table - 1 (iii)(Breaking Strength Weft direction) |
- |
0 |
|
- |
| 3.1.1 and 4.1, Table - 1 (iv)("Resistance to damage by flexing Stage I
") |
- |
0 |
|
- |
| 3.1.1 and 4.1, Table - 1 (iv)("Resistance to damage by flexing Stage II
") |
- |
0 |
|
- |
| 3.1.1 and 4.1, Table - 1 (v)(Thickness) |
- |
0 |
|
- |
| 4.2(Appearance) |
- |
0 |
|
- |
| 4.3(Colour , Grain, Embossing and finish) |
- |
0 |
|
- |
| 4.4.1(Resistance to cold) |
- |
0 |
|
- |
| 4.4.2(Colour fastness to Dry and Wet Rubbing) |
- |
0 |
|
- |
| 4.4.3(Colour fastness to light) |
- |
0 |
|
- |
| 4.4.4(Resistance to heat and loss of mass of coating on heating) |
- |
0 |
|
- |
| 4.4.5(Stability at Vulcanization Temperature) |
- |
0 |
|
- |
| 4.5(Resistance to Gelling) |
- |
0 |
|
- |
| 4.5.1(Embossing on Grain) |
- |
0 |
|
- |
| 4.6(Adhesion of print (for Printed PVC Coated fabrics)) |
- |
0 |
|
- |
| 4.7(Adhesion of coating) |
- |
0 |
|
- |
| Cl-3.1.1, & 4.1 Table-1 (i)(Usable width, cm, Min) |
- |
0 |
|
- |
|
- |
- Included w.e.f.23.06.2025 |
| 4710 |
Electrical Research and Development Association, gujurat
| 7101125
| IS 302 : Part 2 : Sec 80 (2017) |
Household and similar electrical appliances - Safety: Part 2 - 80 particular requirements for fans (First Revision) |
Ceiling fan, Duct fan, Partition fan, pedestal fan, Table fan |
24340 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 6.0(Marking and Instructions) |
- |
500 |
|
- |
| 7.0(Classification) |
- |
0 |
|
- |
| 8.0(Protection against access to live parts) |
- |
500 |
|
- |
| 10.0(Input and Current) |
- |
500 |
|
- |
| 11.0(Heating) |
- |
850 |
|
- |
| 13.0(Leakage Current and electric strength at operating temperature) |
- |
500 |
|
- |
| 14.0(Transient Overvoltage) |
- |
6500 |
|
- |
| 15.0(Moisture resistance) |
- |
2850 |
|
- |
| 16.0(Leakage current and Electric strength (After Humidity (Environmental) Treatment)) |
- |
500 |
|
- |
| 17.0(Overload Protection of transformer and associated circuit) |
- |
500 |
|
- |
| 19.0(Abnormal Operation) |
- |
650 |
|
- |
| 20.0(Stability and mechanical hazards) |
- |
500 |
|
- |
| 21.0(Mechanical Strength) |
- |
1100 |
|
- |
| 22.0(Construction) |
- |
550 |
|
- |
| 23.0(Internal Wiring) |
- |
500 |
|
- |
| 24.0(Components) |
- |
840 |
|
- |
| 25.0(Supply Connection and External Flexible Cords) |
- |
1150 |
|
- |
| 26.0(Terminals for external conductors) |
- |
500 |
|
- |
| 27.0(Provision For Earthing) |
- |
500 |
|
- |
| 28.0(Screws and Connections) |
- |
500 |
|
- |
| 29.0(Creepage Distances and Clearances) |
- |
500 |
|
- |
| 30.0(Resistance To Heat and Fire) |
- |
2850 |
|
- |
| 31.0(Resistance To Rusting) |
- |
500 |
|
- |
| 32.0(Radiation, Toxicity and Similar Hazards) |
- |
500 |
|
- |
| 4(GENERAL REQUIREMENT) |
- |
0 |
|
- |
| 5(GENERAL CONDITIONS FOR THE TESTS) |
- |
0 |
|
- |
| 19.11.4.1(Electrostatic discharges) |
- |
8500 |
|
If this test is applicable than additional test charges of Rs. 8500/- is applied over the total test charge of Rs. 24340/- |
| 19.11.4.2(Radiated fields) |
- |
25000 |
|
If this test is applicable than additional test charges of Rs. 25000/- is applied over the total test charge of Rs. 24340/- |
| 19.11.4.3(Fast transient bursts) |
- |
8500 |
|
If this test is applicable than additional test charges of Rs. 8500/- is applied over the total test charge of Rs. 24340/- |
| 19.11.4.4(Surge immunity test) |
- |
16000 |
|
If this test is applicable than additional test charges of Rs. 16000/- is applied over the total test charge of Rs. 24340/- |
| 19.11.4.5(Immunity to conducted discharges) |
- |
9500 |
|
If this test is applicable than additional test charges of Rs. 9500/- is applied over the total test charge of Rs. 24340/- |
| 19.11.4.6(Class 3 Voltage dips and interruptions) |
- |
15800 |
|
If this test is applicable than additional test charges of Rs. 15800/- is applied over the total test charge of Rs. 24340/- |
| 4(GENERAL REQUIREMENT) |
- |
0 |
|
- |
| 5(GENERAL CONDITIONS FOR THE TESTS) |
- |
0 |
|
- |
| 19.11.4.1(Electrostatic discharges) |
- |
8500 |
|
If this test is applicable than additional test charges of Rs. 8500/- is applied over the total test charge of Rs. 24340/- |
| 19.11.4.2(Radiated fields) |
- |
25000 |
|
If this test is applicable than additional test charges of Rs. 25000/- is applied over the total test charge of Rs. 24340/- |
| 19.11.4.3(Fast transient bursts) |
- |
8500 |
|
If this test is applicable than additional test charges of Rs. 8500/- is applied over the total test charge of Rs. 24340/- |
| 19.11.4.4(Surge immunity test) |
- |
16000 |
|
If this test is applicable than additional test charges of Rs. 16000/- is applied over the total test charge of Rs. 24340/- |
| 19.11.4.5(Immunity to conducted discharges) |
- |
9500 |
|
If this test is applicable than additional test charges of Rs. 9500/- is applied over the total test charge of Rs. 24340/- |
| 19.11.4.6(Class 3 Voltage dips and interruptions) |
- |
15800 |
|
If this test is applicable than additional test charges of Rs. 15800/- is applied over the total test charge of Rs. 24340/- |
| 4(GENERAL REQUIREMENT) |
- |
0 |
|
- |
| 5(GENERAL CONDITIONS FOR THE TESTS) |
- |
0 |
|
- |
| 19.11.4.1(Electrostatic discharges) |
- |
8500 |
|
If this test is applicable than additional test charges of Rs. 8500/- is applied over the total test charge of Rs. 24340/- |
| 19.11.4.2(Radiated fields) |
- |
25000 |
|
If this test is applicable than additional test charges of Rs. 25000/- is applied over the total test charge of Rs. 24340/- |
| 19.11.4.3(Fast transient bursts) |
- |
8500 |
|
If this test is applicable than additional test charges of Rs. 8500/- is applied over the total test charge of Rs. 24340/- |
| 19.11.4.4(Surge immunity test) |
- |
16000 |
|
If this test is applicable than additional test charges of Rs. 16000/- is applied over the total test charge of Rs. 24340/- |
| 19.11.4.5(Immunity to conducted discharges) |
- |
9500 |
|
If this test is applicable than additional test charges of Rs. 9500/- is applied over the total test charge of Rs. 24340/- |
| 19.11.4.6(Class 3 Voltage dips and interruptions) |
- |
15800 |
|
If this test is applicable than additional test charges of Rs. 15800/- is applied over the total test charge of Rs. 24340/- |
|
30 Nov, 2028 |
- Included w.e.f 19.06.2025
Exclusion: Cl 19.11.4.7 (Harmonics) |