| 5551 |
Sleen India Biz venture Private Limited, Agra
| 9139736
| IS 15351 (2015) |
Agro textiles – Laminated high density polyethylene (HDPE) woven geomembrane for water proof lining – Specification (second revision) |
Type-I/II/III/IV |
210000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 3.1(HDPE Tapes) |
- |
1050 |
|
- |
| 3.2(HDPE Fabric) |
- |
1050 |
|
- |
| 5(MANUFACTURE) |
- |
0 |
|
- |
| 5.1(Lamination) |
- |
0 |
|
- |
| 5.2(Panel Width) |
- |
0 |
|
- |
| 5.3(Joints/Seams) |
- |
0 |
|
- |
| 5.1.1 and 6.2(Thickness, mm- IS 7016: Part 1) |
- |
250 |
|
- |
| 5.1.1 and 6.2(Mass, g/sq m) |
- |
250 |
|
- |
| 5.1.1 and 6.2(Dimensions, mm- Annexure A of IS 11652) |
- |
250 |
|
- |
| 5.1.1 and 6.2(Length) |
- |
0 |
|
- |
| 5.1.1 and 6.2(Width) |
- |
0 |
|
- |
| 5.1.1 and 6.2(Carbon black content, Percent- IS 2530) |
- |
925 |
|
- |
| 5.1.1 and 6.2(Breaking Load on 20 cm X 10 cm Strip, Min ) |
- |
1100 |
|
- |
| 5.1.1 and 6.2(Before UV exposure IS 13162 (Part 5) |
- |
0 |
|
- |
| 5.1.1 and 6.2(Strain at Maximum load, Percent-IS 13162 (Part 5) |
- |
1100 |
|
- |
| Table-1(Breaking load on 20 × 10 cm strip, N, Min after) |
- |
1100 |
|
- |
| 5.1.1 and 6.2( U.V exposure of 1000 h for warp and weft) |
- |
96738 |
|
- |
| 5.1.1 and 6.2(Impact failure load, at 1524 mm drop,) |
- |
1100 |
|
- |
| 5.1.1 and 6.2( Min, gram force at 50 percent failure-Annex C) |
- |
1100 |
|
- |
| 5.1.1 and 6.2(Tear resistance, N, Min-Method A1 of
IS 7016 (Part 3)) |
- |
1100 |
|
- |
| 5.1.1 and 6.2(Puncture resistance, N, Min-Annex D) |
- |
1100 |
|
- |
| 5.1.1 and 6.2(Bursting strength (Ball burst),N/cm², Min-) |
- |
1000 |
|
- |
| 5.1.1 and 6.2(IS 7016 (Part 6)) |
- |
0 |
|
- |
| 5.1.1 and 6.2(Seam strength before UV exposure (N/mm), Min-IS 15060) |
- |
1000 |
|
- |
| Table-1(Seam strength after UV exposure N/mm, Min-Annex B and
IS 15060) |
- |
1000 |
|
- |
| 5.1.1 and 6.2(Hydrostatic resistance-Annex E) |
- |
1000 |
|
- |
| Table-1(Hydrostatic resistance after UV exposure of 1000 h -Annex B and
Annex E) |
- |
96737 |
|
- |
| 5.1.1 and 6.2(Ash content, percent, Max-Annex F) |
- |
950 |
|
- |
|
- |
- Included w.e.f 10.07.2025 |
| 5552 |
Samridhi Test House Pvt. Ltd.
| 8184706
| IS/IEC 60529 (2001) |
Degrees of protection provided by enclosures (IP Code) |
Degrees of protection provided by enclosures (IP Code) |
21500 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl-5(Degrees of protection against access to hazardous parts and against solid foreign objects indicated by the first characteristic numeral) |
- |
10500 |
|
- |
| Cl-5.1(Protection against access to hazardous parts) |
- |
8000 |
|
- |
| Cl-5.2(Protection against solid foreign objects) |
- |
8000 |
|
- |
| Cl-6(Degrees of protectlon against ingress of water indicated 'by the second characteristic numeral) |
- |
7500 |
|
- |
| Cl-7(Degrees of protection against access to hazardous parts indicated by the additional letter) |
- |
10500 |
|
- |
| Cl-8(Supplementary letter) |
- |
8000 |
|
- |
| Cl-10(Marking) |
- |
5500 |
|
- |
|
- |
- Included w.e.f 19.06.2025 |
| 5553 |
AJEO TESTING LABS PVT LTD, GHAZIABAD
| 8178606
| IS 7098 : Part 1 (1988) |
Specification for crosslinked polyethylene insulated pvc sheathed cables: Part 1 for working voltages up to and including 1100 volts (First Revision) |
1100 V |
15000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 3(CONDUCTOR: MATERIALS) |
- |
300 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
| 4(INSULATION : MATERIALS) |
- |
300 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
| 5.1(FILLER AND INNER SHEATH) |
- |
300 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
| 5.2(FILLER AND INNER SHEATH) |
- |
300 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
| 6(ARMOURING) |
- |
500 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
| 7(OUTER SHEATH) |
- |
300 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
| 8.1(CONDUCTOR: CONSTRUCTION) |
- |
300 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
| 8.2(PROTECTIVE BARRIER) |
- |
300 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
| 8.3(SIZE OF NEUTRAL CONDUCTOR) |
- |
300 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
| 9.1(Insulation Applied by extrusicn) |
- |
500 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
| 9.2(Thickness of Insulation - Average) |
- |
500 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
| 9.3(Thickness of Insulation - Minimum) |
- |
500 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
| 9.4(Application of Insulation) |
- |
500 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
| 10.1(Core Identification) |
- |
500 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
| 10.2(Core Identification- Neutral) |
- |
500 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
| 10.3(Core Identification by number ) |
- |
300 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
| 10.4(Core Identification by number - Neutral ) |
- |
500 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
| 11(LAVING UP OF CORES) |
- |
500 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
| 12.1 & 12.2(Inner sheath : Application) |
- |
500 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
| 12.3(Thickness of Inner Sheath) |
- |
500 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
| 13.1.2(Armouring: Coverage ) |
- |
500 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
| 13.1.3(Armouring: Direction of Lay ) |
- |
500 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
| 13.2(Type of armour ) |
- |
500 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
| 13.3(Armouring : Dimensions -Wire Diameter) |
- |
500 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra500 |
| 13.3(Armouring : Dimensions -Formed wire ) |
- |
500 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
| 13.4(Armour: Joint) |
- |
500 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
| 13.5(Armouring : Resistance Test) |
- |
800 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
| 13.6 a)(ARMOURING: Tensile Strength) |
- |
500 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
| 13.6 b)(ARMOURING: Elongation ) |
- |
500 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
| 13.6 c)(ARMOURING: Torsion Test (For round wire ) ) |
- |
800 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
| 13.6 d)(ARMOURING: Winding Test(For formed wire)) |
- |
800 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
| 13.6 e)(ARMOURING: Uniformity of zinc coating) |
- |
1000 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
| 13.1(Armouring: Application) |
- |
500 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
| 13.6 f)(ARMOURING: Mass of zinc coating ) |
- |
1000 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
| 13.6 g)(ARMOURING: Resistivity) |
- |
1000 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
| 14.1(Outer Sheath : Application) |
- |
500 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
| 14.2(Colour of outer sheath) |
- |
300 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
| 14.3(Thickness of outer sheath - AVERAGE) |
- |
500 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
| 14.3(Thickness of outer sheath - minimum) |
- |
500 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
| 15.1 a) i)(Annealing Test ( For copper wire ) ) |
- |
800 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
| 15.1 a) ii)(Tensile test (for aluminium) - Before stranding ) |
- |
800 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
| 15.1 a) ii)(Tensile test (for aluminium) - After stranding ) |
- |
800 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
| 15.1 a) iii)(Wrapping test (for aluminium)) |
- |
500 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
| 15.1 a) iv)(Resistance test - Main conductor) |
- |
800 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
| 15.1 a) iv)(Resistance test - Neutral conductor) |
- |
800 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
| 15.1 d) i) (Phyaical tests for insulation : Tensile Test) |
- |
800 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
| 15.1 d) i) (Phyaical tests for insulation : Elongation) |
- |
800 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
| 15.1 d) ii) (Phyaical tests for insulation - Ageing in air Oven : Tensile Variation ) |
- |
800 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
| 15.1 d) ii) (Phyaical tests for insulation- Ageing in air oven : Elongation Variation ) |
- |
1500 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
| 15.1 d) iii) (Phyaical tests for insulation : Hot set ) |
- |
1500 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
| 15.1 d) iii) (Phyaical tests for insulation : Permanent set ) |
- |
1500 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
| 15.1 d) iv) (Phyaical tests for insulation : Shrinkage ) |
- |
800 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
| 15.1 d) iv) (Phyaical tests for insulation : Shrinkage - Crack observed ) |
- |
800 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
| 15.1 d) v) (Insulation: Waterabsorption(gravimetric)) |
- |
3000 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
| 15.1 e) i) (Physical tests for outer sheath : Tensile stregth) |
- |
800 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
| 15.1 e) i) (Physical tests for outer sheath : Elongation) |
- |
800 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
| 15.1 e) ii) (Physical tests for outer sheath- Ageing in air oven : Tensile stregth ) |
- |
1500 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
| 15.1 e) ii) (Physical tests for outer sheath -Ageing in air oven : Elongation ) |
- |
1500 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
| 15.1 e) ii) (Physical tests for outer sheath- Ageing in air oven : Tensile stregth Variation ) |
- |
1500 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
| 15.1 e) ii) (Physical tests for outer sheath -Ageing in air oven : Elongation Variation ) |
- |
1500 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
| 15.1 e) iii) (Sheath: Loss of mass in air oven) |
- |
1500 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
| 15.1 e) iv) (Phyaical tests for Sheath : Shrinkage ) |
- |
800 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
| 15.1 e) iv) (Phyaical tests for Sheath : Shrinkage - Crack observed ) |
- |
800 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
| 15.1 e) v) (Sheath : Hot deformation) |
- |
1000 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
| 15.1 e) vi) (Sheath : Heat shock test) |
- |
800 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
| 15.1 e) vii) (Sheath : Thermalstability) |
- |
1000 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
| 15.1 f)(INSULATION RESISTANCE TEST : Volume resistivity ) |
- |
1200 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
| 16.2(HIGH VOLTAGE TEST ) |
- |
1200 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
| 16.3(FLAMMABILITY TEST : Period of Burning ) |
- |
1200 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
| 16.3(FLAMMABILITY TEST : Unaffected length ) |
- |
1200 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
| 16.9(Oxygen Index Test) |
- |
2500 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
| 16.1(Flame Retardance Test on Single Cables) |
- |
2000 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
| 16.11(Flame Retardance Test on Bunched Cables) |
- |
3000 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
| 16.13(Test for Halogen Acid Gas Evolution) |
- |
2500 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
| 16.14(Temperature Index) |
- |
3000 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
| 17.1(Manufacturer'. identification) |
- |
500 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
| 17.2(cable Indentification ) |
- |
300 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
| 17.3(cable Code ) |
- |
300 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
| 15.4 (a)(Cold bend) |
- |
800 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
| 15.4 (b)(Cold impact) |
- |
800 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
| Table 1(Ageing in air oven - Elongation on Insulation) |
- |
800 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
| Table 1(Ageing in air oven - Tensile strength on Insulation) |
- |
1500 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
| Table 1(Ageing in air oven - Elongation on Insulation) |
- |
1500 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
| Table 1(Ageing in air oven - Tensile strength on Insulation) |
- |
1500 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
| Table 4(Copper purity test) |
- |
3500 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
| Cl No. 16.15(Smoke density test) |
- |
3500 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
| Table 2(Cold Impact test for Outer sheath) |
- |
800 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
| Table 2(Cold bend test for Outer sheath) |
- |
800 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
| Cl 16(Halogen Acid Gas Test) |
- |
2500 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
| Cl 16(Halogen Acid Gas Test) |
- |
2500 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
| Cl 16(Halogen Acid Gas Test) |
- |
2500 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
| Cl.8(Conductor) |
- |
300 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
| Cl.8(Conductor) |
- |
300 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
| Cl.8(Conductor) |
- |
300 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
| Cl.15.4(Cold Bend Test (for outer sheath)) |
- |
800 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
| Cl.15.4(Cold Impact Test (For outer sheath)) |
- |
800 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
| Cl.13.5.1 and Table 7(Resistance Test for Armouring (other than mining Cables)) |
- |
1000 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
|
- |
- Included w.e.f.20.06.2025 |
| 5554 |
SHRI KRISHNA TEST HOUSE PVT LTD (142)
| 8185606
| IS 15558 (2024) |
INSTANTANEOUS DOMESTIC WATER HEATER FOR USE WITH LPG SPECIFICATION First Revision of IS 15558 |
All |
15000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4.1.1(Construction) |
- |
15000 |
|
- |
| 4.1.2(Construction) |
- |
15000 |
|
- |
| 4.1.3(Construction) |
- |
15000 |
|
- |
| 4.1.4(Construction) |
- |
15000 |
|
- |
| 4.1.5(Construction) |
- |
15000 |
|
- |
| 4.1.6(Construction) |
- |
15000 |
|
- |
| 4.1.7(Construction) |
- |
15000 |
|
- |
| 4.1.8(Construction) |
- |
15000 |
|
- |
| 4.1.9(Construction) |
- |
15000 |
|
- |
| 4.1.10(Construction) |
- |
15000 |
|
- |
| 4.1.11(Construction) |
- |
15000 |
|
- |
| 4.1.12(Construction) |
- |
15000 |
|
- |
| 5.1(Materials) |
- |
15000 |
|
- |
| 5.2(Materials) |
- |
15000 |
|
- |
| 5.3(Materials) |
- |
15000 |
|
- |
| 5.4(Materials) |
- |
15000 |
|
- |
| 5.5(Materials) |
- |
15000 |
|
- |
| 6.1(Connections) |
- |
15000 |
|
- |
| 6.2(Connections) |
- |
15000 |
|
- |
| 6.3(Connections) |
- |
15000 |
|
- |
| 6.4(Connections) |
- |
15000 |
|
- |
| 6.5(Connections) |
- |
15000 |
|
- |
| 6.6(Gas Inlet Connections) |
- |
15000 |
|
- |
| 6.6(Gas Inlet Connections) |
- |
15000 |
|
- |
| 6.6(Gas Inlet Connections) |
- |
15000 |
|
- |
| 6.6(Gas Inlet Connections) |
- |
15000 |
|
- |
| 6.6(Gas Inlet Connections) |
- |
15000 |
|
- |
| 6.6(Gas Inlet Connections) |
- |
15000 |
|
- |
| 7(Flame Visibility) |
- |
15000 |
|
- |
| 8(Gas Taps) |
- |
15000 |
|
- |
| 9(Flame Failure Device) |
- |
15000 |
|
- |
| 10(Ignition Device) |
- |
15000 |
|
- |
| 11(Protection Against Accidental Overheating) |
- |
15000 |
|
- |
| 12(Water Rate Adjuster) |
- |
15000 |
|
- |
| 14(Gas Soundness) |
- |
15000 |
|
- |
| 15(Water Soundness) |
- |
15000 |
|
- |
| 16(Thermal Efficiency) |
- |
15000 |
|
- |
| 16(Thermal Efficiency) |
- |
15000 |
|
- |
| 17(Combustion) |
- |
15000 |
|
- |
| 18(Gas Consumption) |
- |
15000 |
|
- |
| 19.1(Ignition and flame travel) |
- |
15000 |
|
- |
| 19.2(Ignition and flame travel) |
- |
15000 |
|
- |
| 19.3(Ignition and flame travel) |
- |
15000 |
|
- |
| 20(Flame Stability) |
- |
15000 |
|
- |
| 21(Noise Control) |
- |
15000 |
|
- |
| 22(Flash Back) |
- |
15000 |
|
- |
| 23(Resistance to Draught) |
- |
15000 |
|
- |
| 24(Fire Hazard And Limiting Temperature ) |
- |
15000 |
|
- |
| 24(Fire Hazard And Limiting Temperature) |
- |
15000 |
|
- |
| 24(Fire Hazard And Limiting Temperature) |
- |
15000 |
|
- |
| 24(Fire Hazard And Limiting Temperature) |
- |
15000 |
|
- |
| 25(Time For Temperature Rise) |
- |
15000 |
|
- |
| 26(Hot Water Output Test) |
- |
15000 |
|
- |
| 27(Marking) |
- |
15000 |
|
- |
| Cl-4(General Requirements) |
- |
15000 |
|
- |
| Cl-5.1(water heater) |
- |
15000 |
|
- |
| Cl-5.2(copper and copper alloy) |
- |
15000 |
|
- |
| Cl-5.3(Non-metallic materials) |
- |
15000 |
|
- |
| Cl-5.4(Mixing tube and burner head) |
- |
15000 |
|
- |
| Cl-6.3(All Water connections) |
- |
15000 |
|
- |
| Cl-6.4(water inlet and outlet connections) |
- |
15000 |
|
- |
| Cl-6.6(Gas Inlet Connections) |
- |
15000 |
|
- |
| Cl-7(Flame visibility) |
- |
15000 |
|
- |
| Cl-8(Gas Taps) |
- |
15000 |
|
- |
| Cl-9(Flame failuse device) |
- |
15000 |
|
- |
| Cl-11(Protection against accidental overheating) |
- |
15000 |
|
- |
| Cl-13(General condition of test) |
- |
15000 |
|
- |
| Cl-14(Gas Soundness) |
- |
15000 |
|
- |
| Cl-15(Water Soundness) |
- |
15000 |
|
- |
| Cl-16(Thermal efficiency) |
- |
15000 |
|
- |
| Cl-17(carbon monoxide/carbon dioxide) |
- |
15000 |
|
- |
| Cl-18(Gas Consumption) |
- |
15000 |
|
- |
| Cl-19(Ignition and flame travel) |
- |
15000 |
|
- |
| Cl-20(FLAME STABILITY) |
- |
15000 |
|
- |
| Cl-21(NOISE CONTROL) |
- |
15000 |
|
- |
| Cl-22(FLASH-BACK) |
- |
15000 |
|
- |
| Cl-24("FIRE HAZARDS AND LIMITING
TEMPERATURE") |
- |
15000 |
|
- |
| Cl-25(TIME FOR TEMPERATURE RISE) |
- |
15000 |
|
- |
| Cl-26(HOT WATER OUTPUT TEST) |
- |
15000 |
|
- |
|
13 May, 2028 |
- Included w.e.f.17.06.2025 |
| 5555 |
EMC Testing and Compliance LLP, Gurugram
| 8141526
| IS 17261 (2022) |
Textiles - Polyester continuous filament fully drawn yarns - Specification (first revision) |
Textiles — Viscose Rayon Cut Staple(Spun) Yarn |
40000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4(Classification (IS 17261)) |
- |
1000 |
|
- |
| 5(Designation ( IS 17261)) |
- |
6000 |
|
5.2.1 a) 2000/- 5.2.1 b) 2000/- 5.2.2) 2000/- |
| 6.1 & Table-3(Linear Density) |
- |
2000 |
|
- |
| 6.1 & Table-3(Uneveness U) |
- |
9000 |
|
- |
| 6.1 & Table-3(Tenacity) |
- |
2000 |
|
- |
| 6.1 & Table-3(Elongation) |
- |
2000 |
|
- |
| 6.2 & Table-4(Moisture regain ( IS17261)) |
- |
2000 |
|
- |
| 6.2 & Table-4(Isophthalic acid (IPA) content (IS 16481)) |
- |
5000 |
|
- |
| 6.2 & Table-4(Water soluble matter (IS 3456)) |
- |
2000 |
|
- |
| 6.2 & Table-4(Finish oil pick-up ( IS17261)) |
- |
2000 |
|
- |
| 6.2 & Table-4(Phosphorus content ( IS17261)) |
- |
2000 |
|
- |
| 6.2 & Table-4(Ultraviolet resistance (IS 13162 (Part-2)) |
- |
5000 |
|
- |
| 6.2 & Table-4(Ultraviolet resistance (IS 13162 (Part-2)) |
- |
5000 |
|
- |
| 6.2 & Table-4(Colour strength with reference to standard yarn ( IS17261)) |
- |
2000 |
|
- |
| 6.2 & Table-4(Colour difference with reference to standard yarn, measured as ΔE ( IS17261)) |
- |
2000 |
|
- |
| 6.3(Freedom From Defects) |
- |
1000 |
|
- |
| 6.5 & Table-6(Colour Fastness Rating To Light Change in colour) |
- |
5000 |
|
- |
| 6.5 & Table-9(Colour Fastness Rating To Rubbing Dry) |
- |
2500 |
|
- |
| 6.5 & Table-10(Colour Fastness Rating To Rubbing Wet) |
- |
2500 |
|
- |
| 6.5 & Table-11(Colour Fastness Rating To Perspiration (acidic and alkaline) Change in colour) |
- |
2500 |
|
- |
| 6.5 & Table-12(Colour Fastness Rating To Perspiration (acidic and alkaline) Staining) |
- |
2500 |
|
- |
| 8(Marking (IS 17261)) |
- |
1000 |
|
- |
| 5.2(Identification and Description, Annex J of IS 16481 & IS 667) |
- |
2500 |
|
- |
| 6.1 Table -3(Boiling water shrinkage, IS 17087) |
- |
2500 |
|
- |
| 6.1 Table -3(Interlace as nips per metre, Annex B of IS 17262) |
- |
2000 |
|
- |
| 6.1 Table -3(No. of filaments in multifilament yarn) |
- |
2000 |
|
- |
| 6.2- Table -4, Sl no. 2 (a)(Isophthalic acid (IPA) content in Virgin polyester yarn, Percent, Annex C of IS 16481) |
- |
5000 |
|
- |
| 6.2- Table -4, Sl no. 2 (b)(Isophthalic acid (IPA) content in Dope dyed/white yarn, Percent, Annex C of IS 16482) |
- |
5000 |
|
- |
| 6.2- Table -4, Sl no. 2 (c)(Isophthalic acid (IPA) content in Recycled polyester yarn, Percent, Annex C of IS 16483) |
- |
5000 |
|
- |
| 6.6(Commercial Mass, IS 7703) |
- |
2000 |
|
- |
| 6.5 Table 6(Colour Fastness to Light) |
- |
5000 |
|
- |
| 6.5 Table 6(Colour Fatness to Washing, Test 2) |
- |
2500 |
|
- |
| 6.5 Table 6(Colour Fastness to Rubbing) |
- |
2500 |
|
- |
| 6.5 Table 6(Colour Fastness to perspiration) |
- |
2500 |
|
- |
| 6.2 Table 4(Moisture Regain , %) |
- |
2000 |
|
- |
| 6.2 Table 4(Water soluble matter %) |
- |
2000 |
|
- |
| 6.2 Table 4(Finish oil pickup, %) |
- |
2000 |
|
- |
| 6.2 Table 4(Phosphorus content , %) |
- |
2000 |
|
- |
| 6.2 Table 4(Phosphorus content , %) |
- |
2000 |
|
- |
| 6.2 Table 4(Colour strength with refernce to standard yarn, %) |
- |
2000 |
|
- |
| 6.2 Table 4(Colour difference with referece standard yarn, measure as DE) |
- |
2000 |
|
- |
| 6.1 Table 3(Linear Density ,Denier (dtex)) |
- |
2000 |
|
- |
| 6.1 Table 3(Unevenness ,(U %)) |
- |
9500 |
|
- |
| 6.1 Table 3(Tenacity,gpd (cN/dtex)) |
- |
2000 |
|
- |
| 6.1 Table 3(Elongation %) |
- |
2000 |
|
- |
| 6.1 Table 3(Boiling Water Shrinkage %) |
- |
2000 |
|
- |
| 6.5 & Table-7(Colour Fastness Rating To Washing Change in colour) |
- |
2000 |
|
- |
| 6.5 & Table-8(Colour Fastness Rating To Washing Staining) |
- |
2000 |
|
- |
| 4(Classification (IS 17261)) |
- |
1000 |
|
- |
| 5(Designation ( IS 17261)) |
- |
6000 |
|
- |
| 6.1 & Table-3(Linear Density) |
- |
2000 |
|
- |
| 6.1 & Table-3(Uneveness U) |
- |
9000 |
|
- |
| 6.1 & Table-3(Tenacity) |
- |
2000 |
|
- |
| 6.1 & Table-3(Elongation) |
- |
2000 |
|
- |
| 6.2 & Table-4(Moisture regain ( IS17261)) |
- |
2000 |
|
- |
| 6.2 & Table-4(Isophthalic acid (IPA) content (IS 16481)) |
- |
5000 |
|
- |
| 6.2 & Table-4(Water soluble matter (IS 3456)) |
- |
2000 |
|
- |
| 6.2 & Table-4(Finish oil pick-up ( IS17261)) |
- |
2000 |
|
- |
| 6.2 & Table-4(Phosphorus content ( IS17261)) |
- |
2000 |
|
- |
| 6.2 & Table-4(Ultraviolet resistance (IS 13162 (Part-2)) |
- |
5000 |
|
- |
| 6.2 & Table-4(Ultraviolet resistance (IS 13162 (Part-2)) |
- |
5000 |
|
- |
| 6.2 & Table-4(Colour strength with reference to standard yarn ( IS17261)) |
- |
2000 |
|
- |
| 6.2 & Table-4(Colour difference with reference to standard yarn, measured as ΔE ( IS17261)) |
- |
2000 |
|
- |
| 6.3(Freedom From Defects) |
- |
1000 |
|
- |
| 6.5 & Table-6(Colour Fastness Rating To Light Change in colour) |
- |
5000 |
|
- |
| 6.5 & Table-9(Colour Fastness Rating To Rubbing Dry) |
- |
2500 |
|
- |
| 6.5 & Table-10(Colour Fastness Rating To Rubbing Wet) |
- |
2500 |
|
- |
| 6.5 & Table-11(Colour Fastness Rating To Perspiration (acidic and alkaline) Change in colour) |
- |
2500 |
|
- |
| 6.5 & Table-12(Colour Fastness Rating To Perspiration (acidic and alkaline) Staining) |
- |
2500 |
|
- |
| 8(Marking (IS 17261)) |
- |
1000 |
|
- |
| 5.2(Identification and Description, Annex J of IS 16481 & IS 667) |
- |
2500 |
|
- |
| 6.1 Table -3(Boiling water shrinkage, IS 17087) |
- |
2500 |
|
- |
| 6.1 Table -3(Interlace as nips per metre, Annex B of IS 17262) |
- |
2000 |
|
- |
| 6.1 Table -3(No. of filaments in multifilament yarn) |
- |
2000 |
|
- |
| 6.2- Table -4, Sl no. 2 (a)(Isophthalic acid (IPA) content in Virgin polyester yarn, Percent, Annex C of IS 16481) |
- |
5000 |
|
- |
| 6.2- Table -4, Sl no. 2 (b)(Isophthalic acid (IPA) content in Dope dyed/white yarn, Percent, Annex C of IS 16482) |
- |
5000 |
|
- |
| 6.2- Table -4, Sl no. 2 (c)(Isophthalic acid (IPA) content in Recycled polyester yarn, Percent, Annex C of IS 16483) |
- |
5000 |
|
- |
| 6.6(Commercial Mass, IS 7703) |
- |
2500 |
|
- |
| 6.5 Table 6(Colour Fastness to Light) |
- |
5000 |
|
- |
| 6.5 Table 6(Colour Fatness to Washing, Test 2) |
- |
2500 |
|
- |
| 6.5 Table 6(Colour Fastness to Rubbing) |
- |
2500 |
|
- |
| 6.5 Table 6(Colour Fastness to perspiration) |
- |
5000 |
|
- |
| 6.2 Table 4(Moisture Regain , %) |
- |
2000 |
|
- |
| 6.2 Table 4(Water soluble matter %) |
- |
2000 |
|
- |
| 6.2 Table 4(Finish oil pickup, %) |
- |
2000 |
|
- |
| 6.2 Table 4(Phosphorus content , %) |
- |
2000 |
|
- |
| 6.2 Table 4(Phosphorus content , %) |
- |
2000 |
|
- |
| 6.2 Table 4(Colour strength with refernce to standard yarn, %) |
- |
2000 |
|
- |
| 6.2 Table 4(Colour difference with referece standard yarn, measure as DE) |
- |
2000 |
|
- |
| 6.1 Table 3(Linear Density ,Denier (dtex)) |
- |
2000 |
|
- |
| 6.1 Table 3(Unevenness ,(U %)) |
- |
9000 |
|
- |
| 6.1 Table 3(Tenacity,gpd (cN/dtex)) |
- |
2000 |
|
- |
| 6.1 Table 3(Elongation %) |
- |
2000 |
|
- |
| 6.1 Table 3(Boiling Water Shrinkage %) |
- |
2500 |
|
- |
| 6.5 & Table-7(Colour Fastness Rating To Washing Change in colour) |
- |
2500 |
|
- |
| 6.5 & Table-8(Colour Fastness Rating To Washing Staining) |
- |
2500 |
|
- |
| 6.4 & Table-5(Lustre/Brightness TiO2 Content) |
- |
2500 |
|
- |
|
19 Jul, 2027 |
- Included w.e.f.22.07.2025
Excluding Cl. 6.2 Table 4 Antimicrobial activity value. Table 7 (mention all) |
| 5556 |
Havells India Limited (Havells Research & Development Laboratory)
| 8187226
| IS/IEC 60947 : Part 5 : Sec 1 (2016) |
Low-Voltage Switchgear And Control Gear : Part 5-1 Control Circuit Devices And Switching Elements Electromechanical Control Circuit Devices |
Control Circuit Devices and Switching Elements |
2065000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 5.2.1(Marking : General
") |
- |
10000 |
|
Only for internal testing |
| 5.2.2(Terminal identification and marking) |
- |
10000 |
|
Only for internal testing |
| 5.2.3(Functional markings) |
- |
0 |
|
Only for internal testing |
| 5.2.5(Operating diagram) |
- |
0 |
|
Only for internal testing |
| 5.2.5.2(Terminal markings for operating diagrams) |
- |
0 |
|
Only for internal testing |
| 5.2.6(Time delay markings) |
- |
0 |
|
Only for internal testing |
| 5.3(Instructions for installation, operation and maintenance) |
- |
0 |
|
Only for internal testing |
| 7.1.2.2(Glow-wire testing) |
- |
15000 |
|
Only for internal testing |
| 7.1.3(Current-carrying parts and their connections) |
- |
0 |
|
Only for internal testing |
| 7.1.4(Clearances and creepage distances) |
- |
10000 |
|
Only for internal testing |
| 7.2.3(Dielectric properties) |
- |
20000 |
|
Only for internal testing |
| 8.2.1.1(Test of resistance to abnormal heat and fire) |
- |
15000 |
|
Only for internal testing |
| 8.2.1.1.1(Glow-wire test) |
- |
15000 |
|
Only for internal testing |
| 8.2.3(Enclosures for equipment) |
- |
0 |
|
Only for internal testing |
| 8.2.4(Mechanical and electrical properties of terminals) |
- |
30000 |
|
Only for internal testing |
| 8.2.4.2(Tests of mechanical strength of terminals) |
- |
30000 |
|
Only for internal testing |
| 8.2.4.3(Testing for damage to and accidental loosening of conductors (flexion test)) |
- |
30000 |
|
Only for internal testing |
| 8.2.4.4(Pull-out test) |
- |
30000 |
|
Only for internal testing |
| 8.2.4.5(Test for insertability of unprepared round copper conductors having the maximum cross-section) |
- |
0 |
|
Only for internal testing |
| 8.2.6(Verification of limitation of rotation (of a rotary switch)) |
- |
30000 |
|
Only for internal testing |
| 8.3.3.3(Temperature rise) |
- |
30000 |
|
Only for internal testing |
| 8.3.3.4(Dielectric properties) |
- |
20000 |
|
Only for internal testing |
| 8.3.3.2(Operating limits of contactor relays) |
- |
20000 |
|
Only for internal testing |
| 8.3.4.3(Test circuit and test quantities) |
- |
0 |
|
Only for internal testing |
| 8.3.4.2(Performance under conditional short-circuit current : Test procedure) |
- |
200000 |
|
Only for internal testing as per each rating |
| 8.3.4.4 b)(Condition of the switching element after the test) |
- |
20000 |
|
Only for internal testing |
| 8.3.4.4 a)(Condition of the switching element after the test) |
- |
20000 |
|
Only for internal testing |
| 8.3.1(Degree of protection of enclosed control circuit devices) |
- |
15000 |
|
Only for internal testing |
| 5.2.1(" Marking : General
") |
- |
0 |
|
Only for internal testing |
| 5.2.2(Terminal identification and marking) |
- |
10000 |
|
Only for internal testing |
| 5.2.3(Functional markings) |
- |
0 |
|
Only for internal testing |
| 5.2.5(Operating diagram) |
- |
0 |
|
Only for internal testing |
| 5.2.5.2(Terminal markings for operating diagrams) |
- |
0 |
|
Only for internal testing |
| 5.2.6(Time delay markings) |
- |
0 |
|
Only for internal testing |
| 5.3(Instructions for installation, operation and maintenance) |
- |
0 |
|
Only for internal testing |
| 7.1.2.2(Glow-wire testing) |
- |
15000 |
|
Only for internal testing |
| 7.1.3(Current-carrying parts and their connections) |
- |
0 |
|
Only for internal testing |
| 7.1.4 of IEC 60947-1:2007 (Sequence 6)(Measurement of Clearances and creepage distances) |
- |
20000 |
|
Only for internal testing |
| 8.3.3.2(Operating limits of contactor relays) |
- |
20000 |
|
Only for internal testing |
| 7.2.3(Dielectric properties) |
- |
20000 |
|
Only for internal testing |
| 8.3.3.4(Dielectric properties) |
- |
20000 |
|
Only for internal testing |
| 8.3.3.3(Temperature rise) |
- |
30000 |
|
Only for internal testing |
| 8.2.6 (Sequence 6)(Verification of limitation of rotation (of a rotary switch)) |
- |
30000 |
|
Only for internal testing |
| 8.2.1.1(Test of resistance to abnormal heat and fire) |
- |
15000 |
|
Only for internal testing |
| 8.2.4.5(Test for insertability of unprepared round copper conductors having the maximum cross-section) |
- |
30000 |
|
Only for internal testing |
| 8.2.1.1.1(Glow-wire test) |
- |
15000 |
|
Only for internal testing |
| 8.2.4.4(Pull-out test) |
- |
30000 |
|
Only for internal testing |
| 8.2.4.3(Testing for damage to and accidental loosening of conductors (flexion test)) |
- |
30000 |
|
Only for internal testing |
| 8.2.4.2(Tests of mechanical strength of terminals) |
- |
30000 |
|
Only for internal testing |
| 8.2.4(Mechanical and electrical properties of terminals) |
- |
30000 |
|
Only for internal testing |
| 8.2.3(Enclosures for equipment) |
- |
0 |
|
Only for internal testing |
| 8.3.3.5.6 b(Dielectric verification) |
- |
20000 |
|
Only for internal testing |
| 8.3.4.1(General conditions for short-circuit tests) |
- |
200000 |
|
Only for internal testing as per each rating |
| Annex C of IEC 60947-1:2007 (Sequence 5)(Degree of protection of enclosed control circuit devices) |
- |
15000 |
|
Only for internal testing |
| 8.3.4.4 a)(Condition of the switching element after the test) |
- |
20000 |
|
Only for internal testing |
| 8.3.4.4 b)(Condition of the switching element after the test) |
- |
20000 |
|
Only for internal testing |
| 8.3.4.1(General conditions for short-circuit tests) |
- |
200000 |
|
Only for internal testing as per each rating |
| 8.3.4.2(Performance under conditional short-circuit current : Test procedure) |
- |
200000 |
|
Only for internal testing as per each rating |
| 8.3.4.3(Test circuit and test quantities) |
- |
200000 |
|
Only for internal testing as per each rating |
| 8.3.4(Performance under Conditional Short-Circuit Current) |
- |
200000 |
|
Only for internal testing as per each rating |
|
07 Aug, 2028 |
- - |
| 5557 |
POWERONIC TEST & RESEARCH CENTRE PRIVATE LIMITED, GREATER NOIDA
| 8170206
| IS 1180 : Part 3 (2021) |
Outdoor/Indoor Type Liquid Immersed Distribution Transformers Up to and Including 2 500 kVA, 33 kV — Specification Part 3 Natural/Synthetic Organic Ester Liquid Immersed |
Up to and Including 2 500 kVA, 33 kV |
115000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 6.1 Table 1(Standard Ratings) |
- |
0 |
|
- |
| 6.2, 7.2, 8.2(Rated Frequency) |
- |
0 |
|
- |
| 6.3, 7.3(Nominal System Voltage) |
- |
0 |
|
- |
| 6.4(Table 2 Minimum Basic Insulation Level) |
- |
0 |
|
- |
| 6.5, 7.5(No-Load Voltage Ratios) |
- |
0 |
|
- |
| 6.6, 7.6(Winding Connections and Phase Displacement) |
- |
0 |
|
- |
| 6.7(Tapping Range and Tapping Methods) |
- |
0 |
|
- |
| 6.8(Table 3 Losses and Impedance Values) |
- |
0 |
|
- |
| 6.9(Permissible Flux Density and Over Fluxing) |
- |
0 |
|
- |
| 6.10(Limits of Temperature-rise) |
- |
0 |
|
- |
| 7.1(Table 4 Standard Ratings) |
- |
0 |
|
- |
| 7.4(Table 5 Minimum Basic Insulation Level) |
- |
0 |
|
- |
| 7.7(Tapping Ranges and Tapping Methods) |
- |
0 |
|
- |
| 7.8(Losses and Impedance Values) |
- |
0 |
|
- |
| 7.9(Permissible Flux Density and Overfluxing) |
- |
0 |
|
- |
| 7.10(Limits of Temperature Rise) |
- |
0 |
|
- |
| 8.1 Table 7(Standard Ratings) |
- |
0 |
|
- |
| 8.3(Nominal System Voltage) |
- |
0 |
|
- |
| 8.5(No Load Voltage Ratio) |
- |
0 |
|
- |
| 8.6(Number of Phases and Polarity) |
- |
0 |
|
- |
| 8.4(Table 8 Minimum Basic Insulation Level) |
- |
0 |
|
- |
| 8.8(Losses and Impedance Values) |
- |
0 |
|
- |
| 8.9(Permissible Flux Density and Overfluxing) |
- |
0 |
|
- |
| 8.10(Limits of Temperature Rise) |
- |
0 |
|
- |
| 9(Standard Materials) |
- |
0 |
|
- |
| 10(Terminal Arrangement) |
- |
0 |
|
- |
| 11(Minimum clearances in air) |
- |
0 |
|
- |
| 12(Connectors (Applicable for bare bushing terminations only)) |
- |
0 |
|
- |
| 13(Marking) |
- |
0 |
|
- |
| 14(Mounting Arrangement) |
- |
0 |
|
- |
| 15(Transformer Tank) |
- |
0 |
|
- |
| 16(Conservator for non-sealed typetransformers) |
- |
0 |
|
- |
| 18(Efficiency and regulation) |
- |
0 |
|
- |
| 19(Tolerances) |
- |
0 |
|
- |
| 20(Fittings) |
- |
0 |
|
- |
| 21.2 a(Measurement of winding resistance
[IS 2026 (Part 1)].) |
- |
5600 |
|
- |
| 21.2 b(Measurement of voltage ratio and check of phase
displacement [IS 2026 (Part 1)].) |
- |
4400 |
|
- |
| 21.2 c(Measurement of short-circuit impedance
(principal tapping, when applicable) and load
loss at 50 percent and 100 percent load
[IS 2026 (Part 1)].) |
- |
4400 |
|
- |
| 21.2 d(Measurement of no-load loss and current
[IS 2026 (Part 1)].) |
- |
2800 |
|
- |
| 21.2 e(Measurement of insulation resistance
[IS 2026 (Part 1)].) |
- |
2000 |
|
- |
| 21.2 f(Induced over-voltage withstand test
[IS 2026 (Part 3)].) |
- |
3600 |
|
- |
| 21.2 g(Separate-source voltage withstand test
[IS 2026 (Part 3)]) |
- |
3200 |
|
- |
| 21.3 a(Lightning impulse test [IS 2026 (Part 3)].) |
- |
32800 |
|
- |
| 21.3 b(Temperature-rise test [IS 2026 (Part 2)].) |
- |
19200 |
|
- |
| 21.3 d(Pressure test) |
- |
4800 |
|
- |
| 21.4 a(Determination of sound levels [IS 2026 (Part 10)];) |
- |
6400 |
|
- |
| 21.4 c(No load current at 112.5 percent voltage
(see 6.9.2, 7.9.2, 8.9.2);) |
- |
800 |
|
- |
| 21.4 d(Paint adhesion test — The test is performed as
per ASTM D3359 (Standard Test Methods for
measuring adhesion by tape test).) |
- |
2400 |
|
- |
| 21.4 e(BDV and Moisture content of liquid in the
transformer (IS 16081, IS 16099, IS 16899 or
IS 16659, whichever is applicable).) |
- |
1600 |
|
- |
| 21.5(Pressure and Ester Liquid Leakage Test) |
- |
6400 |
|
- |
| 4(SERVICE CONDITIONS) |
- |
0 |
|
- |
| 5(General) |
- |
0 |
|
- |
| 6.1(Rating) |
- |
0 |
|
- |
| 6.2(Rated Frequceny) |
- |
0 |
|
- |
| 6.3(Nominal System Voltage) |
- |
0 |
|
- |
| 6.4(Basic Insulation Level) |
- |
0 |
|
- |
| 6.5(No-Load Voltage Ratios) |
- |
0 |
|
- |
| 6.6(Winding connection and phase displacement) |
- |
0 |
|
- |
| 6.7(Tapping range and tapping methods) |
- |
0 |
|
- |
| 6.8(Losses and Impedance Value) |
- |
0 |
|
- |
| 6.9(Permissible flux density and over fluxing) |
- |
0 |
|
- |
| 6.10(Limits of temperature-rise) |
- |
0 |
|
- |
| 7("Technical parameters of three phase distribution
transformers higher ") |
- |
0 |
|
- |
| 8(Technical parameter of single phase distribution transformers) |
- |
0 |
|
- |
| 9(Standard Materials) |
- |
0 |
|
- |
| 10(Terminal Arrangement) |
- |
0 |
|
- |
| 11(Minimum clearances in air) |
- |
0 |
|
- |
| 12(Connectors for bare bushing terminations) |
- |
0 |
|
- |
| 13(Marking) |
- |
0 |
|
- |
| 14(Mounting Arrangement) |
- |
0 |
|
- |
| 15(Trasnformer tank) |
- |
0 |
|
- |
| 16(Conservator for non-sealed type transformers) |
- |
0 |
|
- |
| 18(Efficiency and regulations) |
- |
0 |
|
- |
| 19(Tolerances) |
- |
0 |
|
- |
| 20(Fittings) |
- |
0 |
|
- |
| 21.1(General) |
- |
0 |
|
- |
| 21.2(Routine Tests) |
- |
0 |
|
- |
| 21.3(Types test) |
- |
115000 |
|
Complete testing charges Rs. 71000/- for 0 to 100 kVA, Rs. 88000/- for 100kVA to 250kVA, Rs. 94000/- for 250kVA to 630 kVA, Rs. 96000/- for 630kVA to 1000kVA, Rs. 106000/- for 1000kVA to1600kVA, Rs. 115000/- for 1600kVA to 2500kVA ( 10% Discount to BIS ) |
| 21.4(Special Test) |
- |
14600 |
|
Additional charges if applicable |
| 21.5(Pressure and Ester Liquid Leakage Test) |
- |
0 |
|
- |
| 22(Information required with enquiry and order) |
- |
0 |
|
- |
| 6.1 Table 1(Standard Ratings) |
- |
- |
|
- |
| 6.2, 7.2, 8.2(Rated Frequency) |
- |
- |
|
- |
| 6.3, 7.3(Nominal System Voltage) |
- |
- |
|
- |
| 6.4(Table 2 Minimum Basic Insulation Level) |
- |
- |
|
- |
| 6.5, 7.5(No-Load Voltage Ratios) |
- |
- |
|
- |
| 6.6, 7.6(Winding Connections and Phase Displacement) |
- |
- |
|
- |
| 6.7(Tapping Range and Tapping Methods) |
- |
- |
|
- |
| 6.8(Table 3 Losses and Impedance Values) |
- |
- |
|
- |
| 6.9(Permissible Flux Density and Over Fluxing) |
- |
- |
|
- |
| 6.10(Limits of Temperature-rise) |
- |
- |
|
- |
| 7.1(Table 4 Standard Ratings) |
- |
- |
|
- |
| 7.4(Table 5 Minimum Basic Insulation Level) |
- |
- |
|
- |
| 7.7(Tapping Ranges and Tapping Methods) |
- |
- |
|
- |
| 7.8(Losses and Impedance Values) |
- |
- |
|
- |
| 7.9(Permissible Flux Density and Overfluxing) |
- |
- |
|
- |
| 7.10(Limits of Temperature Rise) |
- |
- |
|
- |
| 8.1 Table 7(Standard Ratings) |
- |
- |
|
- |
| 8.3(Nominal System Voltage) |
- |
- |
|
- |
| 8.5(No Load Voltage Ratio) |
- |
- |
|
- |
| 8.6(Number of Phases and Polarity) |
- |
- |
|
- |
| 8.4(Table 8 Minimum Basic Insulation Level) |
- |
- |
|
- |
| 8.8(Losses and Impedance Values) |
- |
- |
|
- |
| 8.9(Permissible Flux Density and Overfluxing) |
- |
- |
|
- |
| 8.10(Limits of Temperature Rise) |
- |
- |
|
- |
| 9(Standard Materials) |
- |
- |
|
- |
| 10(Terminal Arrangement) |
- |
- |
|
- |
| 11(Minimum clearances in air) |
- |
- |
|
- |
| 12(Connectors (Applicable for bare bushing terminations only)) |
- |
- |
|
- |
| 13(Marking) |
- |
- |
|
- |
| 14(Mounting Arrangement) |
- |
- |
|
- |
| 15(Transformer Tank) |
- |
- |
|
- |
| 16(Conservator for non-sealed typetransformers) |
- |
- |
|
- |
| 18(Efficiency and regulation) |
- |
- |
|
- |
| 19(Tolerances) |
- |
- |
|
- |
| 20(Fittings) |
- |
- |
|
- |
| 21.2 a(Measurement of winding resistance
[IS 2026 (Part 1)].) |
- |
- |
|
- |
| 21.2 b(Measurement of voltage ratio and check of phase
displacement [IS 2026 (Part 1)].) |
- |
- |
|
- |
| 21.2 c(Measurement of short-circuit impedance
(principal tapping, when applicable) and load
loss at 50 percent and 100 percent load
[IS 2026 (Part 1)].) |
- |
- |
|
- |
| 21.2 d(Measurement of no-load loss and current
[IS 2026 (Part 1)].) |
- |
- |
|
- |
| 21.2 e(Measurement of insulation resistance
[IS 2026 (Part 1)].) |
- |
- |
|
- |
| 21.2 f(Induced over-voltage withstand test
[IS 2026 (Part 3)].) |
- |
- |
|
- |
| 21.2 g(Separate-source voltage withstand test
[IS 2026 (Part 3)]) |
- |
- |
|
- |
| 21.3 a(Lightning impulse test [IS 2026 (Part 3)].) |
- |
- |
|
- |
| 21.3 b(Temperature-rise test [IS 2026 (Part 2)].) |
- |
- |
|
- |
| 21.3 d(Pressure test) |
- |
- |
|
- |
| 21.4 a(Determination of sound levels [IS 2026 (Part 10)];) |
- |
- |
|
- |
| 21.4 c(No load current at 112.5 percent voltage
(see 6.9.2, 7.9.2, 8.9.2);) |
- |
- |
|
- |
| 21.4 d(Paint adhesion test — The test is performed as
per ASTM D3359 (Standard Test Methods for
measuring adhesion by tape test).) |
- |
- |
|
- |
| 21.4 e(BDV and Moisture content of liquid in the
transformer (IS 16081, IS 16099, IS 16899 or
IS 16659, whichever is applicable).) |
- |
- |
|
- |
| 21.5(Pressure and Ester Liquid Leakage Test) |
- |
- |
|
- |
| 4(SERVICE CONDITIONS) |
- |
- |
|
- |
| 5(General) |
- |
- |
|
- |
| 6.1(Rating) |
- |
- |
|
- |
| 6.2(Rated Frequceny) |
- |
- |
|
- |
| 6.3(Nominal System Voltage) |
- |
- |
|
- |
| 6.4(Basic Insulation Level) |
- |
- |
|
- |
| 6.5(No-Load Voltage Ratios) |
- |
- |
|
- |
| 6.6(Winding connection and phase displacement) |
- |
- |
|
- |
| 6.7(Tapping range and tapping methods) |
- |
- |
|
- |
| 6.8(Losses and Impedance Value) |
- |
- |
|
- |
| 6.9(Permissible flux density and over fluxing) |
- |
- |
|
- |
| 6.10(Limits of temperature-rise) |
- |
- |
|
- |
| 7("Technical parameters of three phase distribution
transformers higher ") |
- |
- |
|
- |
| 8(Technical parameter of single phase distribution transformers) |
- |
- |
|
- |
| 9(Standard Materials) |
- |
- |
|
- |
| 10(Terminal Arrangement) |
- |
- |
|
- |
| 11(Minimum clearances in air) |
- |
- |
|
- |
| 12(Connectors for bare bushing terminations) |
- |
- |
|
- |
| 13(Marking) |
- |
- |
|
- |
| 14(Mounting Arrangement) |
- |
- |
|
- |
| 15(Trasnformer tank) |
- |
- |
|
- |
| 16(Conservator for non-sealed type transformers) |
- |
- |
|
- |
| 18(Efficiency and regulations) |
- |
- |
|
- |
| 19(Tolerances) |
- |
- |
|
- |
| 20(Fittings) |
- |
- |
|
- |
| 21.1(General) |
- |
- |
|
- |
| 21.2(Routine Tests) |
- |
- |
|
- |
| 21.3(Types test) |
- |
- |
|
- |
| 21.4(Special Test) |
- |
- |
|
- |
| 21.5(Pressure and Ester Liquid Leakage Test) |
- |
- |
|
- |
| 22(Information required with enquiry and order) |
- |
- |
|
- |
|
11 Apr, 2028 |
- Included w.e.f. 04.09.2025
Exclusion: "21.3 c (Short-circuit withstand test [IS 2026 (Part 5)] (up to 200 kVA) and)
21.4 b (Short-circuit withstand test [IS 2026 (Part 5)] (above 200 kVA);)
17 (Ability of transformers to whitstand external short circuit)
" |
| 5558 |
RAJKOT ENGINEERING TESTING AND RESEARCH CENTRE, RAJKOT
| 7167626
| IS 9283 (2024) |
LINE OPERATED A.C. MOTORS FOR SUBMERSIBLE PUMPSETS - SPECIFICATION (THIRD REVISION) |
up to 54kw |
16200 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| As Per Clause 5.1.2 Table 1(Material) |
- |
16200 |
|
2% of total complete testing charge based on kW |
| As Per Clause 5.1.3(Construction-General) |
- |
2 |
|
2% of total complete testing charge based on kW |
| As per Clause 5.1.4(Construction-General) |
- |
2 |
|
2% of total complete testing charge based on kW |
| As per Clause 5.2.1(Earthing) |
- |
2 |
|
2% of total complete testing charge based on kW |
| As per Clause 5.4.1(Construction-Type of cable & Size of conductor of cable) |
- |
2 |
|
2% of total complete testing charge based on kW |
| As per Clause 5.4.2(Construction-Length of cable) |
- |
2 |
|
2% of total complete testing charge based on kW |
| As per Clause 5.4.3(Construction-Joint in Cable) |
- |
2 |
|
2% of total complete testing charge based on kW |
| As per Clause 5.5(Finish of Bearings) |
- |
2 |
|
2% of total complete testing charge based on kW |
| As per Clause 5.6(Balancing of Rotor) |
- |
2 |
|
2% of total complete testing charge based on kW |
| As per Clause 7.1(Dimensions of Motors) |
- |
2 |
|
2% of total complete testing charge based on kW |
| As per Clause 7.2(Tolerances) |
- |
2 |
|
2% of total complete testing charge based on kW |
| As per Clause 12.1(Efficiency) |
- |
2 |
|
2% of total complete testing charge based on kW |
| As per Clause 12.1(Efficiency) |
- |
2 |
|
2% of total complete testing charge based on kW |
| As per Clause 13(Terminal Marking) |
- |
2 |
|
2% of total complete testing charge based on kW |
| As per Clause 15.1(Rating Plate) |
- |
2 |
|
2% of total complete testing charge based on kW |
| As per Clause 15.1(Rating Plate) |
- |
2 |
|
2% of total complete testing charge based on kW |
| As per Clause 15.1(Rating Plate) |
- |
2 |
|
2% of total complete testing charge based on kW |
| As per Clause 15.1(Rating Plate) |
- |
2 |
|
2% of total complete testing charge based on kW |
| As per Clause 15.1(Rating Plate) |
- |
2 |
|
2% of total complete testing charge based on kW |
| As per Clause 15.1(Rating Plate) |
- |
2 |
|
2% of total complete testing charge based on kW |
| As per Clause 15.1(Rating Plate) |
- |
2 |
|
2% of total complete testing charge based on kW |
| As per Clause 15.1(Rating Plate) |
- |
2 |
|
2% of total complete testing charge based on kW |
| As per Clause 15.1(Rating Plate) |
- |
2 |
|
2% of total complete testing charge based on kW |
| As per Clause 15.1(Rating Plate) |
- |
2 |
|
2% of total complete testing charge based on kW |
| As per Clause 15.1(Rating Plate) |
- |
2 |
|
2% of total complete testing charge based on kW |
| As per Clause 15.1(Rating Plate) |
- |
2 |
|
2% of total complete testing charge based on kW |
| As per Clause 15.1(Rating Plate) |
- |
2 |
|
2% of total complete testing charge based on kW |
| As per Clause 15.1(Rating Plate) |
- |
2 |
|
2% of total complete testing charge based on kW |
| As per Clause 15.1(Rating Plate) |
- |
2 |
|
2% of total complete testing charge based on kW |
| As per Clause 15.2(Rating Plate) |
- |
2 |
|
2% of total complete testing charge based on kW |
| As per Clause 16.1(a),21(Insulationresistance test(Before HV Test)) |
- |
2 |
|
2% of total complete testing charge based on kW |
| As per Clause 16.1(a),21(Insulationresistance test(After HV Test)) |
- |
2 |
|
2% of total complete testing charge based on kW |
| As per Clause 16.1(b),20(High voltage test) |
- |
2 |
|
2% of total complete testing charge based on kW |
| As per Clause 16.[c](Measurement of stator resistance) |
- |
2 |
|
2% of total complete testing charge based on kW |
| As per Clause 16.(d)(No Load Test) |
- |
2 |
|
2% of total complete testing charge based on kW |
| As per Clause 16.(e)(Reduced voltage running up test at no load) |
- |
2 |
|
2% of total complete testing charge based on kW |
| As per Clause 16.(f)(Locked rotor readings of voltage, current, power input and torque of motors) |
- |
2 |
|
2% of total complete testing charge based on kW |
| As per Clause 16.(g)(Full load reading of voltage, current, power input, speed and frequency) |
- |
2 |
|
2% of total complete testing charge based on kW |
| As per Clause 16.(h),11(Performance characteristics) |
- |
2 |
|
2% of total complete testing charge based on kW |
| As per Clause 16.(j),19(Temperature rise test at rated voltage) |
- |
2 |
|
2% of total complete testing charge based on kW |
| As per Clause 16.(k),19(Temperature rise test at reduced voltage) |
- |
2 |
|
2% of total complete testing charge based on kW |
| As per Clause 16.(m),18(Momentary Overload Test) |
- |
2 |
|
2% of total complete testing charge based on kW |
| As per Clause 16.(n),22(Leakage Current Test at rated voltage at no load) |
- |
2 |
|
2% of total complete testing charge based on kW |
| As Per Clause 5.1.2 Table 1(Material) |
- |
2 |
|
2% of total complete testing charge based on kW |
| As Per Clause 5.1.3(Construction-General) |
- |
2 |
|
2% of total complete testing charge based on kW |
| As per Clause 5.1.4(Construction-General) |
- |
2 |
|
2% of total complete testing charge based on kW |
| As per Clause 5.2.1(Earthing) |
- |
2 |
|
2% of total complete testing charge based on kW |
| As per Clause 5.4.1(Construction-Type of cable & Size of conductor of cable) |
- |
2 |
|
2% of total complete testing charge based on kW |
| As per Clause 5.4.2(Construction-Length of cable) |
- |
2 |
|
2% of total complete testing charge based on kW |
| As per Clause 5.4.3(Construction-Joint in Cable) |
- |
2 |
|
2% of total complete testing charge based on kW |
| As per Clause 5.5(Finish of Bearings) |
- |
2 |
|
2% of total complete testing charge based on kW |
| As per Clause 5.6(Balancing of Rotor) |
- |
2 |
|
2% of total complete testing charge based on kW |
| As per Clause 7.1(Dimensions of Motors) |
- |
2 |
|
2% of total complete testing charge based on kW |
| As per Clause 7.2(Tolerances) |
- |
2 |
|
2% of total complete testing charge based on kW |
| As per Clause 12.1(Efficiency) |
- |
2 |
|
2% of total complete testing charge based on kW |
| As per Clause 12.1(Efficiency) |
- |
2 |
|
2% of total complete testing charge based on kW |
| As per Clause 13(Terminal Marking) |
- |
2 |
|
2% of total complete testing charge based on kW |
| As per Clause 15.1(Rating Plate) |
- |
2 |
|
2% of total complete testing charge based on kW |
| As per Clause 15.1(Rating Plate) |
- |
2 |
|
2% of total complete testing charge based on kW |
| As per Clause 15.1(Rating Plate) |
- |
2 |
|
2% of total complete testing charge based on kW |
| As per Clause 15.1(Rating Plate) |
- |
2 |
|
2% of total complete testing charge based on kW |
| As per Clause 15.1(Rating Plate) |
- |
2 |
|
2% of total complete testing charge based on kW |
| As per Clause 15.1(Rating Plate) |
- |
2 |
|
2% of total complete testing charge based on kW |
| As per Clause 15.1(Rating Plate) |
- |
2 |
|
2% of total complete testing charge based on kW |
| As per Clause 15.1(Rating Plate) |
- |
2 |
|
2% of total complete testing charge based on kW |
| As per Clause 15.1(Rating Plate) |
- |
2 |
|
2% of total complete testing charge based on kW |
| As per Clause 15.1(Rating Plate) |
- |
2 |
|
2% of total complete testing charge based on kW |
| As per Clause 15.1(Rating Plate) |
- |
2 |
|
2% of total complete testing charge based on kW |
| As per Clause 15.1(Rating Plate) |
- |
2 |
|
2% of total complete testing charge based on kW |
| As per Clause 15.1(Rating Plate) |
- |
2 |
|
2% of total complete testing charge based on kW |
| As per Clause 15.1(Rating Plate) |
- |
2 |
|
2% of total complete testing charge based on kW |
| As per Clause 15.1(Rating Plate) |
- |
2 |
|
2% of total complete testing charge based on kW |
| As per Clause 15.2(Rating Plate) |
- |
2 |
|
2% of total complete testing charge based on kW |
| As per Clause 16.1(a),21(Insulationresistance test(Before HV Test)) |
- |
2 |
|
2% of total complete testing charge based on kW |
| As per Clause 16.1(a),21(Insulationresistance test(After HV Test)) |
- |
2 |
|
2% of total complete testing charge based on kW |
| As per Clause 16.1(b),20(High voltage test) |
- |
2 |
|
2% of total complete testing charge based on kW |
| As per Clause 16.[c](Measurement of stator resistance) |
- |
2 |
|
2% of total complete testing charge based on kW |
| As per Clause 16.(d)(No Load Test) |
- |
2 |
|
2% of total complete testing charge based on kW |
| As per Clause 16.(e)(Reduced voltage running up test at no load) |
- |
2 |
|
2% of total complete testing charge based on kW |
| As per Clause 16.(f)(Locked rotor readings of voltage, current, power input and torque of motors) |
- |
2 |
|
2% of total complete testing charge based on kW |
| As per Clause 16.(g)(Full load reading of voltage, current, power input, speed and frequency) |
- |
2 |
|
2% of total complete testing charge based on kW |
| As per Clause 16.(h),11(Performance characteristics) |
- |
2 |
|
2% of total complete testing charge based on kW |
| As per Clause 16.(j),19(Temperature rise test at rated voltage) |
- |
2 |
|
2% of total complete testing charge based on kW |
| As per Clause 16.(k),19(Temperature rise test at reduced voltage) |
- |
2 |
|
2% of total complete testing charge based on kW |
| As per Clause 16.(m),18(Momentary Overload Test) |
- |
2 |
|
2% of total complete testing charge based on kW |
| As per Clause 16.(n),22(Leakage Current Test at rated voltage at no load) |
- |
2 |
|
2% of total complete testing charge based on kW |
| As Per Clause 5.1.2 Table 1(Material) |
- |
2 |
|
2% of total complete testing charge based on kW |
| As Per Clause 5.1.3(Construction-General) |
- |
2 |
|
2% of total complete testing charge based on kW |
| As per Clause 5.1.4(Construction-General) |
- |
2 |
|
2% of total complete testing charge based on kW |
| As per Clause 5.2.1(Earthing) |
- |
2 |
|
2% of total complete testing charge based on kW |
| As per Clause 5.4.1(Construction-Type of cable & Size of conductor of cable) |
- |
2 |
|
2% of total complete testing charge based on kW |
| As per Clause 5.4.2(Construction-Length of cable) |
- |
2 |
|
2% of total complete testing charge based on kW |
| As per Clause 5.4.3(Construction-Joint in Cable) |
- |
2 |
|
2% of total complete testing charge based on kW |
| As per Clause 5.5(Finish of Bearings) |
- |
2 |
|
2% of total complete testing charge based on kW |
| As per Clause 5.6(Balancing of Rotor) |
- |
2 |
|
2% of total complete testing charge based on kW |
| As per Clause 7.1(Dimensions of Motors) |
- |
2 |
|
2% of total complete testing charge based on kW |
| As per Clause 7.2(Tolerances) |
- |
2 |
|
2% of total complete testing charge based on kW |
| As per Clause 12.1(Efficiency) |
- |
2 |
|
2% of total complete testing charge based on kW |
| As per Clause 12.1(Efficiency) |
- |
2 |
|
2% of total complete testing charge based on kW |
| As per Clause 13(Terminal Marking) |
- |
2 |
|
2% of total complete testing charge based on kW |
| As per Clause 15.1(Rating Plate) |
- |
2 |
|
2% of total complete testing charge based on kW |
| As per Clause 15.1(Rating Plate) |
- |
2 |
|
2% of total complete testing charge based on kW |
| As per Clause 15.1(Rating Plate) |
- |
2 |
|
2% of total complete testing charge based on kW |
| As per Clause 15.1(Rating Plate) |
- |
2 |
|
2% of total complete testing charge based on kW |
| As per Clause 15.1(Rating Plate) |
- |
2 |
|
2% of total complete testing charge based on kW |
| As per Clause 15.1(Rating Plate) |
- |
2 |
|
2% of total complete testing charge based on kW |
| As per Clause 15.1(Rating Plate) |
- |
2 |
|
2% of total complete testing charge based on kW |
| As per Clause 15.1(Rating Plate) |
- |
2 |
|
2% of total complete testing charge based on kW |
| As per Clause 15.1(Rating Plate) |
- |
2 |
|
2% of total complete testing charge based on kW |
| As per Clause 15.1(Rating Plate) |
- |
2 |
|
2% of total complete testing charge based on kW |
| As per Clause 15.1(Rating Plate) |
- |
2 |
|
2% of total complete testing charge based on kW |
| As per Clause 15.1(Rating Plate) |
- |
2 |
|
2% of total complete testing charge based on kW |
| As per Clause 15.1(Rating Plate) |
- |
2 |
|
2% of total complete testing charge based on kW |
| As per Clause 15.1(Rating Plate) |
- |
2 |
|
2% of total complete testing charge based on kW |
| As per Clause 15.1(Rating Plate) |
- |
2 |
|
2% of total complete testing charge based on kW |
| As per Clause 15.2(Rating Plate) |
- |
2 |
|
2% of total complete testing charge based on kW |
| As per Clause 16.1(a),21(Insulationresistance test(Before HV Test)) |
- |
2 |
|
2% of total complete testing charge based on kW |
| As per Clause 16.1(a),21(Insulationresistance test(After HV Test)) |
- |
2 |
|
2% of total complete testing charge based on kW |
| As per Clause 16.1(b),20(High voltage test) |
- |
2 |
|
2% of total complete testing charge based on kW |
| As per Clause 16.[c](Measurement of stator resistance) |
- |
2 |
|
2% of total complete testing charge based on kW |
| As per Clause 16.(d)(No Load Test) |
- |
2 |
|
2% of total complete testing charge based on kW |
| As per Clause 16.(e)(Reduced voltage running up test at no load) |
- |
2 |
|
2% of total complete testing charge based on kW |
| As per Clause 16.(f)(Locked rotor readings of voltage, current, power input and torque of motors) |
- |
2 |
|
2% of total complete testing charge based on kW |
| As per Clause 16.(g)(Full load reading of voltage, current, power input, speed and frequency) |
- |
2 |
|
2% of total complete testing charge based on kW |
| As per Clause 16.(h),11(Performance characteristics) |
- |
2 |
|
2% of total complete testing charge based on kW |
| As per Clause 16.(j),19(Temperature rise test at rated voltage) |
- |
2 |
|
2% of total complete testing charge based on kW |
| As per Clause 16.(k),19(Temperature rise test at reduced voltage) |
- |
2 |
|
2% of total complete testing charge based on kW |
| As per Clause 16.(m),18(Momentary Overload Test) |
- |
2 |
|
2% of total complete testing charge based on kW |
| As per Clause 16.(n),22(Leakage Current Test at rated voltage at no load) |
- |
2 |
|
2% of total complete testing charge based on kW |
|
25 Mar, 2027 |
- Included w.e.f.04.07.2025 |
| 5559 |
POWERONIC TEST & RESEARCH CENTRE PRIVATE LIMITED, GREATER NOIDA
| 8170206
| IS 1180 : Part 1 (2014) |
Outdoor Type Oil Immersed Distribution Transformers Upto and Including 2 500 kVA, 33kV - Specification Part 1 Mineral Oil Immersed (Fourth Revision) |
Upto and Including 2 500 kVA, 33kV |
112000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 13.1(Marking (Rating Plates)) |
- |
0 |
|
Complete Testing Charges : Rs.70000/- For 0 to 100 kVA, Rs.81000/- For 100 to 250 kVA, Rs.85000- For 250 kVA to 630 kVA, Rs.86100/- For 630 kVA to 1000 kVA, Rs.110900/- For 1000 kVA to 1600 kVA. Rs.112000/- For 1600 kVA to 2500 kVA |
| 13.2(Terminal Marking Plate) |
- |
0 |
|
- |
| 13.3(Marking ) |
- |
0 |
|
- |
| 13.4(Marking) |
- |
0 |
|
- |
| 13.4.1(Marking) |
- |
0 |
|
- |
| 14.1(MOUNTING ARRANGEMENT) |
- |
0 |
|
- |
| 14.2(MOUNTING ARRANGEMENT) |
- |
0 |
|
- |
| 14.3(MOUNTING ARRANGEMENT) |
- |
0 |
|
- |
| 14.4(MOUNTING ARRANGEMENT) |
- |
0 |
|
- |
| 15.1.1(TRANSFORMER TANK : Construction) |
- |
0 |
|
- |
| 15.1.2(TRANSFORMER TANK : Construction) |
- |
0 |
|
- |
| 15.1.3(TRANSFORMER TANK : Construction) |
- |
0 |
|
- |
| 15.1.4(TRANSFORMER TANK : Construction) |
- |
0 |
|
- |
| 15.1.5(TRANSFORMER TANK : Construction) |
- |
0 |
|
- |
| 21.2 a)(Measurement of winding resistance ) |
- |
5400 |
|
- |
| 21.2 b)( Measurement of voltage ratio and check of
phase displacemen) |
- |
4500 |
|
- |
| 21.2 c)( Measurement of short-circuit impedance
(principal tapping, when applicable) and load
loss at 50 percent and 100 percent load) |
- |
4500 |
|
- |
| 21.2 d)(Measurement of no-load loss and current) |
- |
3150 |
|
- |
| 21.2 e)(Measurement of insulation resistance) |
- |
1800 |
|
- |
| 21.2 f)(Induced over-voltage withstand test) |
- |
4050 |
|
- |
| 21.2 g)( Separate-source voltage withstand test) |
- |
3600 |
|
- |
| 21.5.3.3(Oil leakage test) |
- |
2700 |
|
- |
| 21.3(a )(Lightning impulse test) |
- |
34200 |
|
- |
| 21.3(b)(Temperature-rise test) |
- |
20700 |
|
- |
| 21.4 a)( Determination of sound levels) |
- |
5400 |
|
- |
| 21.5.1.1(Pressure test-Type test (For Transformers up to 200 kVA
)) |
- |
5400 |
|
- |
| 21.5.1.2(Pressure test-routine test (For Transformers up to 200 kVA
)) |
- |
3600 |
|
- |
| 21.5.2.1(Type test : For Transformers Above 200 kVA and Up to Including 2 500 kVA) |
- |
108000 |
|
- |
| 21.5.2.2(routine test :For Transformers Above 200 kVA and Up to Including 2 500 kVA) |
- |
32000 |
|
Routine Testing Charges : Rs.17000/- For 0 to 100 kVA, Rs.18200/- For 100 to 250 kVA, Rs.21700/- For 250 kVA to 630 kVA, Rs.22600/- For 630 kVA to 1000 kVA, Rs.28100/- For 1000 kVA to 1600 kVA. Rs.32000/- For 1600 kVA to 2500 kVA. |
| 21.5.2.3( Oil leakage test (routine test)) |
- |
0 |
|
- |
| 21.5.3.1(For Single Phase Distribution Transformers Up to Including 25 kVA : pressure test (type test)) |
- |
0 |
|
- |
| 21.5.3.2(For Single Phase Distribution Transformers Up to Including 25 kVA : pressure test (routine test)) |
- |
0 |
|
- |
| 21.5.3.3(Oil leakage test (routine test)) |
- |
0 |
|
- |
| 21.4 c(No load current at 112.5 percent voltage.) |
- |
0 |
|
- |
| 21.4 d(Paint adhesion tests) |
- |
0 |
|
- |
| 21.4 e(BDV and moisture content of oil in the transformer) |
- |
0 |
|
- |
| 15.5(Total Dry Film Paint Thickness) |
- |
0 |
|
- |
| 6.9, 7.9, 8.9(Permissible Flux Density and Over Fluxing) |
- |
0 |
|
- |
| 11(Minimum clearance in Air) |
- |
0 |
|
- |
| 16(Conservator for Non-sealed type Transformers) |
- |
0 |
|
- |
| 20(Fittings) |
- |
0 |
|
- |
| 6.8 (50%)(Total losses at 50 % load (Watts)) |
- |
0 |
|
- |
| 7.8 (50%)(Total losses at 50 % load (Watts)) |
- |
0 |
|
- |
| 8.8 (50%)(Total losses at 50 % load (Watts)) |
- |
0 |
|
- |
| 6.8 (100%)(Total losses at 100 % load (Watts)) |
- |
0 |
|
- |
| 7.8 (100%)(Total losses at 100 % load (Watts)) |
- |
0 |
|
- |
| 8.8 (100%)(Total losses at 100 % load (Watts)) |
- |
0 |
|
- |
| 21.5.1.3(Oil leakage test upto 200 KVA) |
- |
0 |
|
- |
| 9.1a)(CRGO Electrical Steel) |
- |
0 |
|
- |
| 9.1 b)(Amorphous core material) |
- |
0 |
|
- |
| 9.1 c)(Copper/Aluminium conductor) |
- |
0 |
|
- |
| 9.1 d)(Kraft paper) |
- |
0 |
|
- |
| 9.1 e)(Press Board) |
- |
0 |
|
- |
| 9.1 f)(Mineral oil) |
- |
0 |
|
- |
| 10(Terminal Arrangement) |
- |
0 |
|
- |
| 15.2(Pressure and Vacuum Requirements) |
- |
0 |
|
- |
| 15.4(Gasket) |
- |
0 |
|
- |
| 19(Tolerances) |
- |
0 |
|
- |
| 18(Efficiency and regulation) |
- |
0 |
|
- |
| 4(Service Conditions) |
- |
0 |
|
- |
| 5(General ) |
- |
0 |
|
- |
| 6.1(Rating) |
- |
0 |
|
- |
| 6.2(Rated frequency) |
- |
0 |
|
- |
| 6.3(Nominal system voltage) |
- |
0 |
|
- |
| 6.4(Basic Insulation level ) |
- |
0 |
|
- |
| 6.5(No-Load Voltage Ratios) |
- |
0 |
|
- |
| 6.6(Winding connections and phase displacement) |
- |
0 |
|
- |
| 6.7(Tapping Range and Tapping Method) |
- |
0 |
|
- |
| 6.8(Losses and impedance values) |
- |
0 |
|
- |
| 6.9(Permissible Flux Density and Over Fluxing ) |
- |
0 |
|
- |
| 6.1(Limits of Temperature-rise) |
- |
0 |
|
- |
| 7(Technical Parameters of three phase distribution trasnformers
higher than 200kva) |
- |
0 |
|
- |
| 8(Technical Parameters of single phase distribution transformers
UP to and including 25 KVA ) |
- |
0 |
|
- |
| 9(Standard Materials) |
- |
0 |
|
- |
| 10(Terminal arrangment ) |
- |
0 |
|
- |
| 11(Minimum Clearnaces air ) |
- |
0 |
|
- |
| 12(Connectors ) |
- |
0 |
|
- |
| 13(Marking ) |
- |
0 |
|
- |
| 14(Mounting arrangement) |
- |
0 |
|
- |
| 15(Trasnformer Tank ) |
- |
0 |
|
- |
| 16(Conservator for Non-Sealed type Transformers) |
- |
0 |
|
- |
| 18(Efficiency and Regulation) |
- |
0 |
|
- |
| 19(Tolerances) |
- |
0 |
|
- |
| 20(Fittings) |
- |
0 |
|
- |
| 21(General ) |
- |
0 |
|
- |
| 22(Information required with enquiry and order ) |
- |
0 |
|
- |
| 13.1(Marking (Rating Plates)) |
- |
0 |
|
- |
| 13.2(Terminal Marking Plate) |
- |
0 |
|
- |
| 13.3(Marking ) |
- |
0 |
|
- |
| 13.4(Marking) |
- |
0 |
|
- |
| 13.4.1(Marking) |
- |
0 |
|
- |
| 14.1(MOUNTING ARRANGEMENT) |
- |
0 |
|
- |
| 14.2(MOUNTING ARRANGEMENT) |
- |
0 |
|
- |
| 14.3(MOUNTING ARRANGEMENT) |
- |
0 |
|
- |
| 14.4(MOUNTING ARRANGEMENT) |
- |
0 |
|
- |
| 15.1.1(TRANSFORMER TANK : Construction) |
- |
0 |
|
- |
| 15.1.2(TRANSFORMER TANK : Construction) |
- |
0 |
|
- |
| 15.1.3(TRANSFORMER TANK : Construction) |
- |
0 |
|
- |
| 15.1.4(TRANSFORMER TANK : Construction) |
- |
0 |
|
- |
| 15.1.5(TRANSFORMER TANK : Construction) |
- |
0 |
|
- |
| 21.2 a)(Measurement of winding resistance ) |
- |
0 |
|
- |
| 21.2 b)( Measurement of voltage ratio and check of
phase displacemen) |
- |
0 |
|
- |
| 21.2 c)( Measurement of short-circuit impedance
(principal tapping, when applicable) and load
loss at 50 percent and 100 percent load) |
- |
0 |
|
- |
| 21.2 d)(Measurement of no-load loss and current) |
- |
0 |
|
- |
| 21.2 e)(Measurement of insulation resistance) |
- |
0 |
|
- |
| 21.2 f)(Induced over-voltage withstand test) |
- |
0 |
|
- |
| 21.2 g)( Separate-source voltage withstand test) |
- |
0 |
|
- |
| 21.5.3.3(Oil leakage test) |
- |
0 |
|
- |
| 21.3(a )(Lightning impulse test) |
- |
0 |
|
- |
| 21.3(b)(Temperature-rise test) |
- |
0 |
|
- |
| 21.4 a)( Determination of sound levels) |
- |
0 |
|
- |
| 21.5.1.1(Pressure test-Type test (For Transformers up to 200 kVA
)) |
- |
0 |
|
- |
| 21.5.1.2(Pressure test-routine test (For Transformers up to 200 kVA
)) |
- |
0 |
|
- |
| 21.5.2.1(Type test : For Transformers Above 200 kVA and Up to Including 2 500 kVA) |
- |
0 |
|
- |
| 21.5.2.2(routine test :For Transformers Above 200 kVA and Up to Including 2 500 kVA) |
- |
0 |
|
- |
| 21.5.2.3( Oil leakage test (routine test)) |
- |
0 |
|
- |
| 21.5.3.1(For Single Phase Distribution Transformers Up to Including 25 kVA : pressure test (type test)) |
- |
0 |
|
- |
| 21.5.3.2(For Single Phase Distribution Transformers Up to Including 25 kVA : pressure test (routine test)) |
- |
0 |
|
- |
| 21.5.3.3(Oil leakage test (routine test)) |
- |
0 |
|
- |
| 21.4 c(No load current at 112.5 percent voltage.) |
- |
0 |
|
- |
| 21.4 d(Paint adhesion tests) |
- |
0 |
|
- |
| 21.4 e(BDV and moisture content of oil in the transformer) |
- |
0 |
|
- |
| 15.5(Total Dry Film Paint Thickness) |
- |
0 |
|
- |
| 6.9, 7.9, 8.9(Permissible Flux Density and Over Fluxing) |
- |
0 |
|
- |
| 11(Minimum clearance in Air) |
- |
0 |
|
- |
| 16(Conservator for Non-sealed type Transformers) |
- |
0 |
|
- |
| 20(Fittings) |
- |
0 |
|
- |
| 6.8 (50%)(Total losses at 50 % load (Watts)) |
- |
0 |
|
- |
| 7.8 (50%)(Total losses at 50 % load (Watts)) |
- |
0 |
|
- |
| 8.8 (50%)(Total losses at 50 % load (Watts)) |
- |
0 |
|
- |
| 6.8 (100%)(Total losses at 100 % load (Watts)) |
- |
0 |
|
- |
| 7.8 (100%)(Total losses at 100 % load (Watts)) |
- |
0 |
|
- |
| 8.8 (100%)(Total losses at 100 % load (Watts)) |
- |
0 |
|
- |
| 21.5.1.3(Oil leakage test upto 200 KVA) |
- |
0 |
|
- |
| 9.1a)(CRGO Electrical Steel) |
- |
0 |
|
- |
| 9.1 b)(Amorphous core material) |
- |
0 |
|
- |
| 9.1 c)(Copper/Aluminium conductor) |
- |
0 |
|
- |
| 9.1 d)(Kraft paper) |
- |
0 |
|
- |
| 9.1 e)(Press Board) |
- |
0 |
|
- |
| 9.1 f)(Mineral oil) |
- |
0 |
|
- |
| 10(Terminal Arrangement) |
- |
0 |
|
- |
| 15.2(Pressure and Vacuum Requirements) |
- |
0 |
|
- |
| 15.4(Gasket) |
- |
0 |
|
- |
| 19(Tolerances) |
- |
0 |
|
- |
| 18(Efficiency and regulation) |
- |
0 |
|
- |
| 4(Service Conditions) |
- |
0 |
|
- |
| 5(General ) |
- |
0 |
|
- |
| 6.1(Rating) |
- |
0 |
|
- |
| 6.2(Rated frequency) |
- |
0 |
|
- |
| 6.3(Nominal system voltage) |
- |
0 |
|
- |
| 6.4(Basic Insulation level ) |
- |
0 |
|
- |
| 6.5(No-Load Voltage Ratios) |
- |
0 |
|
- |
| 6.6(Winding connections and phase displacement) |
- |
0 |
|
- |
| 6.7(Tapping Range and Tapping Method) |
- |
0 |
|
- |
| 6.8(Losses and impedance values) |
- |
0 |
|
- |
| 6.9(Permissible Flux Density and Over Fluxing ) |
- |
0 |
|
- |
| 6.1(Limits of Temperature-rise) |
- |
0 |
|
- |
| 7(Technical Parameters of three phase distribution trasnformers
higher than 200kva) |
- |
0 |
|
- |
| 8(Technical Parameters of single phase distribution transformers
UP to and including 25 KVA ) |
- |
0 |
|
- |
| 9(Standard Materials) |
- |
0 |
|
- |
| 10(Terminal arrangment ) |
- |
0 |
|
- |
| 11(Minimum Clearnaces air ) |
- |
0 |
|
- |
| 12(Connectors ) |
- |
0 |
|
- |
| 13(Marking ) |
- |
0 |
|
- |
| 14(Mounting arrangement) |
- |
0 |
|
- |
| 15(Trasnformer Tank ) |
- |
0 |
|
- |
| 16(Conservator for Non-Sealed type Transformers) |
- |
0 |
|
- |
| 18(Efficiency and Regulation) |
- |
0 |
|
- |
| 19(Tolerances) |
- |
0 |
|
- |
| 20(Fittings) |
- |
0 |
|
- |
| 21(General ) |
- |
0 |
|
- |
| 22(Information required with enquiry and order ) |
- |
0 |
|
- |
|
11 Apr, 2028 |
- Included w.e.f. 01.09.2025
Exclusion
17 ( ABILITY OF TRANSFORMERS TO WITHSTAND EXTERNAL SHORT CIRCUIT )
21.4 b (Short-circuit withstand test IS 2026 (Part 5) (above 200 kVA))
21.3(c) (Short-circuit withstand test) |
| 5560 |
THE SOUTH INDIA TEXTILE RESEARCH ASSOCIATION (SITRA), COIMBATORE
| 6165234
| IS 12171 (2024) |
Cotton Bales Specification Fourth Revision |
- |
4248 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl-5.1.1(Staple Length) |
- |
625 |
|
CHARGES INCLUSIVE OF STAPLE LENGTH, STRENGTH, MICRONAIRE VALUE IN HVI INSTRUMENT. |
| Cl-5.1.2(Trash Content) |
- |
625 |
|
TRASH CONTENT |
| Cl-5.1.3(Moisture Content) |
- |
750 |
|
MOISTURE CONTENT |
| Cl-5.1.4(Strength of Fibre) |
- |
625 |
|
CHARGES INCLUSIVE OF STAPLE LENGTH, STRENGTH, MICRONAIRE VALUE IN HVI INSTRUMENT. |
| Cl-5.1.5(Micronaire Value) |
- |
625 |
|
CHARGES INCLUSIVE OF STAPLE LENGTH, STRENGTH, MICRONAIRE VALUE IN HVI INSTRUMENT. |
| Cl-5.1.1(Staple Length) |
- |
625 |
|
CHARGES INCLUSIVE OF STAPLE LENGTH, STRENGTH, MICRONAIRE VALUE IN HVI INSTRUMENT. |
| Cl-5.1.2(Trash Content) |
- |
625 |
|
TRASH CONTENT |
| Cl-5.1.3(Moisture Content) |
- |
750 |
|
MOISTURE CONTENT |
| Cl-5.1.4(Strength of Fibre) |
- |
625 |
|
CHARGES INCLUSIVE OF STAPLE LENGTH, STRENGTH, MICRONAIRE VALUE IN HVI INSTRUMENT. |
| Cl-5.1.5(Micronaire Value) |
- |
625 |
|
CHARGES INCLUSIVE OF STAPLE LENGTH, STRENGTH, MICRONAIRE VALUE IN HVI INSTRUMENT. |
|
- |
- Included w.e.f.28.07.2025
Exclusion
For clause 5.1.5 only |
| 5561 |
Institute for Auto Parts and Hand Tools Technology, Ludhiana
| 9126034
| IS 13352 (1992) |
Stock for forgings produced from continuously cast blooms, billets and slabs - Specification |
All Grade / Type / Size / Designation as per IS 13352 |
56010 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 3.1(General requirements) |
- |
0 |
|
- |
| 5(Freedom from defects) |
- |
500 |
|
- |
| 6.1, table 2 (2)(C) |
- |
1460 |
|
C, SI, Mn, P, S,=100/PER ELEMENT
Ni, Cr, Mo, Cu, V, B, Ti, Sn, Al= 120/ PER ELEMENT |
| 6.1, table 2 (3)(Mn) |
- |
0 |
|
- |
| 6.1, table 2 (4)(Si) |
- |
0 |
|
- |
| 6.1, table 2 (5)(Ni) |
- |
0 |
|
- |
| 6.1, table 2 (6)(Cr) |
- |
0 |
|
- |
| 6.1, table 2 (7)(Mo) |
- |
0 |
|
- |
| 6.1, table 2 (8)(V) |
- |
0 |
|
- |
| 6.1, table 2 (9)(Al) |
- |
0 |
|
- |
| 6.1, table 3 (1)(Carbon
Silicon
Manganese
Nickel
Chromium
Molybdenum
Vanadium
Sulphur
Phosphorus) |
- |
0 |
|
- |
| 7(Mechanical properties) |
- |
14300 |
|
Upto 100 mmdia or RCS =3900/-
Upto 101 to 200 mm dia or RCS = 5900
Upto 201to 250 mm dia or RCS = 6900/-
For impact test
Upto 100 mmdia or RCS =4000 per set
101 to 200 mm dia or RCS = 6000 per set
201 to 250 mm dia or RCS = 7000 per set |
| 8(Grain size) |
- |
1150 |
|
- |
| 9.1(Surface defects) |
- |
6000 |
|
- |
| 9.2(Seams) |
- |
7500 |
|
UT= 1000/-
Blank hardening =6000/-
Microstructure= 500/- |
| 10.1(Inclusion rating of the steel) |
- |
400 |
|
- |
| 10.2(Step down test & magnetic particle test) |
- |
5000 |
|
- |
| 11(Hardenability) |
- |
9000 |
|
sample Up to 34-100 mm dia or RCS =7000/-
Up to 101 to 200 mm dia or RCS = 8000/-
Up to 201 to 250 mm dia or RCS = 9000/- |
| 12(Dimensions and Tolerances) |
- |
1200 |
|
- |
| 14(Retest) |
- |
9500 |
|
Blue Fracture Test
Upto 90 mmdia or RCS =7500/-
Upto 91 to 150 mm dia or RCS = 8500
Upto 151 to 250 mm dia or RCS = 9500 |
| 16(Marking) |
- |
0 |
|
- |
|
17 Feb, 2028 |
- Included w.e.f.28.07.2025 |
| 5562 |
Bharat Test House Pvt. Ltd. 1668 Sonipat
| 9168306
| IS 14606 (2022) |
Irrigation Equipment - Media Filter |
- |
7500 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Clause No.5(Technical characterstic) |
- |
500 |
|
- |
| Clause No.6.(Mechanical test) |
- |
500 |
|
- |
| Clause No.6.(Mechanical test) |
- |
1000 |
|
- |
| "Clauseno. 6.2.3.1 Table no. 2"(Test Conditions and Requirements) |
- |
1000 |
|
- |
| Clause No.7(Resistance to cyclic pressure) |
- |
1000 |
|
- |
| Clause No.8(Hydraulic Parameters And Tests) |
- |
1000 |
|
- |
| Clause No.9("BACK FLUSHING HYDRAULIC
PARAMETERS AND TESTS") |
- |
500 |
|
- |
| Clause No.10.("Automatic Back flushing and
controller") |
- |
500 |
|
- |
| Clause No.11.(information to be supplied by the manufacturer) |
- |
100 |
|
- |
| Clause No.12.(Back Flushing controller) |
- |
100 |
|
- |
| Clause No.13.(Maintance label) |
- |
100 |
|
- |
| Clause No.16(Acceptance Test) |
- |
100 |
|
- |
| Clause No.17(MARKING) |
- |
100 |
|
- |
| 5.1(General) |
- |
100 |
|
- |
| 5.2(Inlet and Expansion Space Chamber) |
- |
100 |
|
- |
| 5.3(Media (main filtering) Compartment) |
- |
100 |
|
- |
| 5.4(Underdrain (Collection) and Back Flush Unit) |
- |
100 |
|
- |
| 5.5.1(Threaded ends) |
- |
100 |
|
- |
| 5.5.2(Flanged connections) |
- |
100 |
|
- |
| 5.5.3(Dimensions) |
- |
100 |
|
- |
| 6.1(General) |
- |
500 |
|
- |
| 6.2.1(Preparation) |
- |
1000 |
|
- |
| 6.2.2(Metal Filter Housing(Tank)) |
- |
1000 |
|
- |
| 6.2.3.1(Plastics moulded material of filter housing
) |
- |
1000 |
|
- |
| 6.3(Resistance of Filter to Internal Hydrostatic Pressure
at High Temperature) |
- |
1000 |
|
- |
| 7(RESISTANCE TO CYCLIC PRESSURE) |
- |
1000 |
|
- |
| 8.1.1(Clean Pressure Drop (Pressure Loss)) |
- |
1000 |
|
- |
| 8.1.2(Test Period) |
- |
1000 |
|
- |
| 8.3.1(Flows) |
- |
500 |
|
- |
| 8.3.2(Inlet and Outlet Pressures) |
- |
500 |
|
- |
| 8.3.3(Testing Sequence) |
- |
500 |
|
- |
| 9.1(Test for Flushing Mechanism) |
- |
500 |
|
- |
| 9.2(Detecting Media Escape) |
- |
100 |
|
- |
| 10.1(Backwash Initiation) |
- |
500 |
|
- |
| 10.2.1(Mechanism Activated by Pressure
Differential Sensor) |
- |
500 |
|
- |
| 10.2.2(Mechanism Activated by Duration of Operation) |
- |
500 |
|
- |
| 10.2.3(Mechanism Activated by Volume of Filtered Water) |
- |
500 |
|
- |
| 10.2.4(Mechanism Activated by Some Other Physical Quantity) |
- |
500 |
|
- |
| 10.2.5(Test of Protective Device) |
- |
500 |
|
- |
|
- |
- Included w.e.f.12.09.2025 |
| 5563 |
EKO PRO ENGINEERS PRIVATE LIMITED (32/37) GHAZIABAD
| 8164006
| IS 14650 (2023) |
UNALLOYED AND ALLOYED STEEL INGOT AND SEMI-FINISHED PRODUCTS FOR RE-ROLLING PURPOSES - SPECIFICATION (First Revision) |
- |
6000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Clause - 7.1(CARBON) |
- |
3000 |
|
- |
| Clause - 7.1(SULPHUR) |
- |
3000 |
|
- |
| Clause - 7.1(PHOSPHURS) |
- |
3000 |
|
- |
| Clause - 7.1(MANGANESE) |
- |
3000 |
|
- |
| Clause - 7.1(NITROGEN) |
- |
3000 |
|
- |
| As per Clause 10(Dimension) |
- |
3000 |
|
- |
| As per Clause 10.1(Dimension Width) |
- |
3000 |
|
- |
| As per Clause 10.1(Dimension Thickness) |
- |
3000 |
|
- |
| As per Clause 10.2(Dimension Length) |
- |
3000 |
|
- |
| As per Clause 11/11.1/11.2/11.3/11.4(Tolerances) |
- |
3000 |
|
- |
| As per Clause 11.5(Bend) |
- |
3000 |
|
- |
| As per Clause 11.6(Camber) |
- |
3000 |
|
- |
| As per Clause 11.7 (i)(Out of Square) |
- |
3000 |
|
- |
| As per Clause 11.7 (ii)(Round Corners) |
- |
3000 |
|
- |
| As per Clause 11.7 (iii)(Ridges due to gas cutting) |
- |
3000 |
|
- |
| As per Clause 11.7 (iv)(Taper (Width variation on top and bottom surface at one location) |
- |
3000 |
|
- |
| As per Clause 11.7 (v)(Edge slanting (Width variation on top and bottom surface at one location) |
- |
3000 |
|
- |
| As per Clause 11.7 (vi)(Convexity(Difference in thickness from edge to curve) |
- |
3000 |
|
- |
| As per Clause 11.7 (vii)(Chamfering (Length variation on top and bottom surface at one location) |
- |
3000 |
|
- |
| As per Clause 11.7 (viii)(Wedge (Thickness variation at the edges along the cross section) |
- |
3000 |
|
- |
| As per Clause 11.7 (ix)(Scarfing pits) |
- |
3000 |
|
- |
| As per Clause 12/12.1/12.2/12.3(Freedom from defects) |
- |
0 |
|
- |
| Clause. 14(Marking) |
- |
0 |
|
- |
| Clause.15(Ordering information) |
- |
0 |
|
- |
| Clause.6.0(Manufacture) |
- |
0 |
|
- |
| Clause.7.1(Silicon) |
- |
3000 |
|
- |
| Clause.7.1(Carbon Equbalant) |
- |
3000 |
|
- |
| Clause.7.1(Microalloy element) |
- |
3000 |
|
- |
|
27 May, 2028 |
- Included w.e.f 31.07.2025
Exclusion: Clause. 13 (Macro examination test.), Clause. 13 (Sulphur print.), Clause. 13 (Inclusion content) |
| 5564 |
CIPET. MYSURU
| 6113734
| IS 7834 : Part 4 (1987) |
injection moulded PVC socket fittings with solvent cement joints for water supplies: Part 4 Specific requirements for 90 degree tees |
- |
7294 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 2.2.2, Table 1(Size) |
- |
375 |
|
For all Dimensions |
| 2.2.2, Table 1(90 ̊ Elbow Laying
Length) |
- |
0 |
|
Included in dimensions |
| 2.2.3( inside diameter of the socket) |
- |
0 |
|
Included in dimensions |
| 2.2.3(Socket length) |
- |
0 |
|
Included in dimensions |
| 2.1(General) |
- |
0 |
|
Included in next |
| 2.1(General) |
- |
6918.75 |
|
RS.3843 is for addition of (Stress relief test Rs. 525, OpacityRs. 431.25, EOW. Rs.2250, &Short-term hydraulic test Rs. 637.50) Rs. 637.50 for socket fitting . And
Rs. 3075 for raw material ( VCM Content Rs.2250 & K Value Rs. 825) |
| 2.2.3(Socket length) |
- |
0 |
|
- |
|
31 Dec, 2026 |
- - |
| 5565 |
CIPET. MYSURU
| 6113734
| IS 7834 : Part 2 (1987) |
injection moulded PVC socket fittings with solvent cement joints for water supplies: Part 2 Specific requirements for 45 degrees elbows |
- |
7294 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 2.2.2, Table 1(Size) |
- |
375 |
|
Thickness |
| 2.2.3(socket length) |
- |
0 |
|
Included In Thickness |
| 2.1(General) |
- |
431.25 |
|
Opacity |
| 2.2.2, Table 1(45 ̊ Elbow Laying
Length) |
- |
0 |
|
Included In Thickness |
| 2.2.3( inside diameter of the socket) |
- |
5962.75 |
|
Included In Thickness
Effect on water Rs.2250/- & hydro pressure test Rs.637.50 for pipes
VCM Content -Rs. 2250/- & K Value Rs. 825/- for raw material |
| 2.1(General) |
- |
525 |
|
Stress relief test |
| 6.1.1(VCM Content Test) |
- |
0 |
|
- |
| 2.2.2, Table 1(Size) |
- |
0 |
|
- |
|
31 Dec, 2026 |
- - |
| 5566 |
CIPET. MYSURU
| 6113734
| IS 7834 : Part 6 (1987) |
injection moulded PVC socket fittings with solvent cement joints for water supplies: Part 6 Specific requirements for sockets |
- |
7294 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 2.2.2, Table 1(Size) |
- |
375 |
|
For All Dimensions |
| 2.2.2, Table 1(Socket Laying
Length) |
- |
0 |
|
Included in above dimension charges |
| 2.2.3( inside diameter of the socket) |
- |
0 |
|
Included in above dimension charges |
| 2.2.3(Socket length) |
- |
0 |
|
Included in above dimension charges |
| 2.1(General) |
- |
0 |
|
Added in below charges |
| 2.1(General) |
- |
6918.75 |
|
RS.3843 is for addition of (Stress relief test Rs. 525, Opacity Rs. 431.25, EOW. Rs.2250, &Short-term hydraulic test Rs. 637.50) Rs. 637.50 for socket fitting . And
Rs. 3075 for raw material ( VCM Content Rs.2250 & K Value Rs. 825) |
| 6.1.1(VCM Content Test) |
- |
0 |
|
- |
|
31 Dec, 2026 |
- - |
| 5567 |
CIPET. MYSURU
| 6113734
| IS 14887 (2014) |
Textiles – High density polyethylene (HDPE)/ polypropylene (PP) woven sacks for packaging of 50 kg food grains – Specification (first revision) |
HDPE woven sacks for packaging 50kg food grains |
19117.50 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 3.2(Tapes – Width and Thickness
( IS 6192/IS 11197)) |
- |
187.50 |
|
Tapes – Width and Thickness
( IS 6192/IS 11197) |
| 3.2(Tapes – Linear Density
(IS 6192/IS 11197)) |
- |
0 |
|
Tapes – Linear Density
(IS 6192/IS 11197) |
| 3.2(Tapes – Tenacity (IS 6192/IS 11197)) |
- |
187.50 |
|
Tapes – Tenacity (IS 6192/IS 11197) |
| 4.2 and Table 1 ii(Dimensions ) |
- |
187.50 |
|
Dimension |
| 3.2(Tapes – Dimensional stability (PP)
(IS 11197)) |
- |
1500 |
|
Tapes – Dimensional stability (PP)
(IS 11197) include identification |
| 4.2 and Table 1 ix(Average breaking strength and elongation at break of UV stabilized HDPE/PP fabric after been exposed to UV radiation and weathering ) |
- |
12830 |
|
Average breaking strength and elongation at break of UV stabilized HDPE/PP fabric after been exposed to UV radiation and weathering |
| 4.2 and Table 1 vi(Average breaking strength of fabric ) |
- |
2650 |
|
Average breaking strength of fabric |
| 4.2 and Table 1 vi(Breaking strength of bottom seam ) |
- |
1325 |
|
Breaking strength of bottom seam |
| 4.2 and Table 1 viii(Elongation at break of fabric ) |
- |
0 |
|
Elongation at break of fabric |
| 4.2 and Table 1 x(Ash content ) |
- |
712.5 |
|
Ash content |
| 4.2 and Table 1 v(Mass of sack ) |
- |
225 |
|
Mass of sack |
| 5.2 and Table 1 iii(Ends per dm ) |
- |
187.5 |
|
Ends per dm |
| 5.2 and Table 1 iv(Picks per dm ) |
- |
187.5 |
|
Picks per dm |
| 3.2(MFI) |
- |
825 |
|
MFI |
| 3.1(Overall Migration) |
- |
1275 |
|
Overall Mig |
| 3.1(Material Identification) |
- |
1500 |
|
Identification |
| 3.2(Tapes – Heat Shrinkage (HDPE) (Cl. 3.2 and IS 6192)) |
- |
825 |
|
Heat Shrinkage |
| 4.1 and 3.4(Mass of bale (Cl. 4.1), Capacity (Cl 3.4)) |
- |
0 |
|
Included in dimension |
| 3.3.1(Bottom seam (IS 10789)) |
- |
0 |
|
Included in dimension |
|
31 Dec, 2026 |
- - |
| 5568 |
CIPET. MYSURU
| 6113734
| IS 7834 : Part 1 (1987) |
injection moulded PVC socket fittings with solvent cement joints for water supplies: Part 1 General requirements |
Injection moulded PVC Socket fittings |
4219 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl.4(Minimum Thickness) |
- |
375 |
|
it will cover all dimension |
| Cl. 5.1.1, 5.1.2, Table 1, Fig 1(Minimum Socket Length) |
- |
0 |
|
it will cover all dimension |
| Cl. 5.1.1, 5.1.2, Table 1, Fig 1(Mean Socket Internal Diameter at Mid-Point of Socket Length) |
- |
0 |
|
it will cover all dimension |
| Cl. 5.1.1, 5.1.2, Table 1, Fig 1(Out-of-roundness tolerances of socket inside diameter) |
- |
0 |
|
it will cover all dimension |
| Cl. 6.1(Stress Relief Test- Appendix A) |
- |
525 |
|
for stress relief |
| Cl. 6.2(Opacity- Appendix B) |
- |
431.25 |
|
for opacity |
| Cl. 6.3(Effect on Water[(Lead ( first extraction )]- Appendix C) |
- |
2250 |
|
for complete effect on water |
| Cl. 6.3(Effect on Water[(Lead ( third extraction )]- Appendix C) |
- |
0 |
|
for complete effect on water |
| Cl. 6.3(Effect on Water [Dialkyl tin C4, and higher homologues, measured as tin ( third extraction )]- Appendix C) |
- |
0 |
|
for complete effect on water |
| Cl. 6.3(Effect on Water [Other toxic substances ( third extraction )]- Appendix C) |
- |
0 |
|
for complete effect on water |
| Cl. 6.4(Short-Term Hydraulic Test- Appendix D) |
- |
637.50 |
|
for short term test |
| 6.1.1(VCM Content Test) |
- |
0 |
|
- |
| 3(Size of Fitting -) |
- |
0 |
|
- |
|
31 Dec, 2026 |
- - |
| 5569 |
CIPET. MYSURU
| 6113734
| IS 7834 : Part 3 (1987) |
injection moulded PVC socket fittings with solvent cement joints for water supplies: Part 3 Specific requirements for 90 degree elbows |
- |
7294 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| cl 2.2.2(Dimensions) |
- |
375 |
|
For Dimensions Thickness & Socket length) |
| Cl. 2.1 (Ref. Cl. 6.3 of IS 7834 (part 1) : 1987(Effect on water - Lead (first extraction) - Appendix C ) |
- |
2250 |
|
For EOW Including all element detection |
| Cl. 2.1 (Ref. Cl. 6.3 of IS 7834 (part 1) : 1987(Effect on water - Lead (third extraction) - Appendix C) |
- |
0 |
|
Included above |
| Cl. 2.1 (Ref. Cl. 6.3 of IS 7834 (part 1) : 1987(Effect on water - Dialkyl tin C4 and higher homologues measured as tin (third extraction) - Appendix C) |
- |
0 |
|
Included above |
| Cl. 2.1 (Ref. Cl. 6.3 of IS 7834 (part 1) : 1987(Effect on water - Other toxic substances (third extraction) - Appendix C) |
- |
4668.75 |
|
EOW water charges included above,
RS.1593 is for addition of (Stress relief test Rs. 525, OpacityRs. 431.25, Short-term hydraulic test Rs. 637.50) Rs. 637.50 for socket fitting . And
Rs. 3075 for raw material ( VCM Content Rs.2250 & K Value Rs. 825) |
| 2.2.2 table 1(Laying length) |
- |
0 |
|
- |
| 6.1.1(VCM Content Test) |
- |
2250 |
|
- |
|
31 Dec, 2026 |
- - |
| 5570 |
CIPET. MYSURU
| 6113734
| IS 7834 : Part 5 (1987) |
Injection Moulded PVC Socket Fittings With Solvent Cement Joints for Water Supplies - Part 5 : Specific Requirements for 45 degree Tees |
- |
7294 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 2.2.2, Table 1(Size) |
- |
375 |
|
All DImensions |
| 2.2.2, Table 1(45 ̊ Tees Laying
Length, Z) |
- |
0 |
|
Included in above dimension charges |
| 2.2.3( inside diameter of the socket) |
- |
0 |
|
Included in above dimension charges |
| 2.2.3(Socket length) |
- |
0 |
|
Included in above dimension charges |
| 2.1(General) |
- |
6918 |
|
RS.3843 is for addition of (Stress relief test Rs. 525, OpacityRs. 431.25, EOW. Rs.2250, &Short-term hydraulic test Rs. 637.50) Rs. 637.50 for socket fitting . And
Rs. 3075 for raw material ( VCM Content Rs.2250 & K Value Rs. 825) |
| 6.1.1(VCM Content Test) |
- |
0 |
|
- |
|
31 Dec, 2026 |
- - |
| 5571 |
CIPET. MYSURU
| 6113734
| IS 7834 : Part 7 (1987) |
injection moulded PVC socket fittings with solvent cement joints for water supplies: Part 7 Specific requirements for unions |
- |
7294 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 2.2.2, Table 1(Size) |
- |
375 |
|
For All Dimensions |
| 2.2.2, Table 1(Union Laying
Length) |
- |
0 |
|
Included in above dimension charges |
| 2.2.3( inside diameter of the socket) |
- |
0 |
|
Included in above dimension charges |
| 2.2.3(Socket length) |
- |
0 |
|
Included in above dimension charges |
| 2.1(General) |
- |
0 |
|
Added in below charges |
| 2.1(General) |
- |
6918.75 |
|
RS.3843 is for addition of (Stress relief test Rs. 525, OpacityRs. 431.25, EOW. Rs.2250, &Short-term hydraulic test Rs. 637.50) Rs. 637.50 for socket fitting . And
Rs. 3075 for raw material ( VCM Content Rs.2250 & K Value Rs. 825) |
| 6.1.1(VCM Content Test) |
- |
0 |
|
- |
|
31 Dec, 2026 |
- - |
| 5572 |
CIPET. MYSURU
| 6113734
| IS 12701 (1996) |
Rotational moulded polyethylene water storage tanks - specification (First Revision) |
Upto 20000 litres |
17144 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4.2.3(Carbon Black Content ) |
- |
693.75 |
|
CBC |
| 4.2.3(Carbon Dispersion Test) |
- |
525 |
|
CBD |
| 5(Types and Features ) |
- |
1200 |
|
CL. 4.1.1 density & MFI |
| 5.1 Table 1(Dimensioas of Cylinderical Vertical Tank) |
- |
2512.50 |
|
5.1,5.2,5.3&5.4 & 6.1 |
| 7.1.1(Resistance to Deformation) |
- |
525 |
|
Resistance to Deformation |
| 7.2(Resistance to Impact) |
- |
825 |
|
Resistance to Impact |
| 7.3(Test for Top Load Resistance) |
- |
675 |
|
Test for Top Load Resistance |
| 7.4(Tensile Strength) |
- |
1325 |
|
Tensile Strength |
| 7.5(Flexural Modulus) |
- |
1325 |
|
Flexural Modulus |
| 7.6(overall Migration) |
- |
7537.50 |
|
Cl. 7.6, 9.1, 8.2 & Raw material |
| 5.4(Wall Thickness) |
- |
0 |
|
- |
| 6.1(Finish) |
- |
0 |
|
- |
| 9.2.1(Man-Hole and Hand-Hole Lids) |
- |
0 |
|
- |
| 4.2.2(MFR) |
- |
0 |
|
- |
|
31 Dec, 2026 |
- - |
| 5573 |
CIPET. MYSURU
| 6113734
| IS 7834 : Part 8 (1987) |
injection moulded PVC socket fittings with solvent cement joints for water supplies: Part 8 Specific requirements for caps |
- |
7294 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 2.2.2(diameter of the socket of cap) |
- |
375 |
|
For All Dimensions |
| 2.1(General) |
- |
6918.75 |
|
RS.3843 is for addition of (Stress relief test Rs. 525, OpacityRs. 431.25, EOW. Rs.2250, &Short-term hydraulic test Rs. 637.50) Rs. 637.50 for socket fitting . And
Rs. 3075 for raw material ( VCM Content Rs.2250 & K Value Rs. 825) |
| 6.1.1(VCM Content Test) |
- |
0 |
|
- |
|
31 Dec, 2026 |
- - |
| 5574 |
Institute for Auto Parts and Hand Tools Technology, Ludhiana
| 9126034
| IS 6149 (1984) |
Specification for single - Ended open - Jaw adjustable wrenches (First Revision) |
All Grade, Type, Size and Designation |
6840 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4 Table-1(Dimensions- Nominal Size) |
- |
1200 |
|
- |
| 4 Table-1(Dimensions- a) |
- |
0 |
|
-- |
| 4 Table-1(Dimensions- b) |
- |
0 |
|
-- |
| 4 Table-1(Dimensions- t) |
- |
0 |
|
-- |
| 4 Table-1(Dimensions- d) |
- |
0 |
|
-- |
| 4 Table-1(Dimensions- Opening of adjustable jaws) |
- |
0 |
|
-- |
| 6(Hardness- Frame, handle and Jaw) |
- |
3560 |
|
Hardness= 400
Coating Thickness- 460
Adhesion Test- 200
Corrosion Resistance- 2000
Workmanship=500 |
| 8(Longitudinal Play of Adjustable Jaw) |
- |
300 |
|
--- |
| 8(Transverse Play of Adjustable Jaw) |
- |
300 |
|
--- |
| 8(Torque) |
- |
500 |
|
--- |
| 5(Chemical Composition) |
- |
980 |
|
- |
|
17 Feb, 2028 |
- - |
| 5575 |
CIPET. MYSURU
| 6113734
| IS 12786 (1989) |
Irrigation equipment - Polyethylene pipes for irrigation laterals - Specification |
Diameter - 32 mm |
13325 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4.1.a (Potyethylene - higher olefins constituent ) |
- |
1500 |
|
Potyethylene - higher olefins constituent |
| 7.3(Tensile Test) |
- |
975 |
|
For tensile & Elongation |
| 7.3(Elongation at Break) |
- |
0.00 |
|
included in tensile |
| 7.4(SusceptibiIity to Environmental Stress
Cracking) |
- |
900.00 |
|
E s c r |
| 5 and Table 1(DIMENSIONS OF PIPES - outside diameters) |
- |
0 |
|
For all dim |
| 7.2(Reversion Test) |
- |
825.00 |
|
reversion
Rs. 525 test & RS. 300 Specimen prep |
| 5 and Table 1(DIMENSIONS OF PIPES - wall thickness shall) |
- |
375 |
|
Dimension charges |
| 4.1.c.ii (Toluene extract - Annex A) |
- |
900 |
|
Toluene extract - |
| 4.1.c.iii (Volatile matter - Annex B ) |
- |
900 |
|
Volatile matter |
| 4.1.c & 4.2.a (Carbon Black content - IS 2530 : 1963) |
- |
694 |
|
CBC |
| 4.2.b (The dispersion of Carbon Black content shall be satisfactory - IS 2530 : 1963) |
- |
525.03 |
|
The dispersion of Carbon Black content shall be satisfactory - IS 2530 : 1963 |
| 7.1
Table-2
(b)Acceptance Test for 01 hour at 20°C & 6.9MPa induced stress) |
- |
638 |
|
b) Acceptance Test for 01 hour at 20°C & 6.9MPa induced stress |
| Cl. 7.1 Table -2(Quality Test for 100 hrs @ 70 c & 2.2 Mpa) |
- |
2250.01 |
|
Quality Test for 100 hrs @ 70 c & 2.2 Mpa |
| 6(VISUAL APPEARANCE) |
- |
225 |
|
VISUAL APPEARANCE |
| 4.1.c.i (Density) |
- |
1200 |
|
Density |
| 4.1d(MATERIAL) |
- |
1500 |
|
MATERIAL |
|
31 Dec, 2026 |
- - |
| 5576 |
CIPET. MYSURU
| 6113734
| IS 14333 (2022) |
Polyethylene Pipes for Sewerage and Industrial Chemicals and Effluent � Specification (First Revision) |
Diameter upto 400mm |
39545 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 7.4,T3 of IS 4984(Outside Diameter-IS 4984-2016) |
- |
375 |
|
Dimension all |
| 5.2.1,T2("Base Density
(At 27°C Temp.)-IS 7328:2020 ") |
- |
1200 |
|
Density |
| 6.2(Colour- IS 14333-2022) |
- |
225 |
|
Colour |
| 8.1.1, T4(Internal Pressure creep Rupture test, Temperature - 27 oC , Test Period - 100 hrs.-IS 4984-2016 (Annexure-E)) |
- |
2250 |
|
100 hrs Pressure test |
| 8.1.1, T4(Internal Pressure creep Rupture test, Temperature - 80 oC , Test Period - 48 hrs.-IS 4984-2016 (Annexure-E)) |
- |
1200 |
|
48 hrs pressure test |
| 8.2("Longitudinal Reversion Test - IS 4984-2016
(Annexure-F)") |
- |
825 |
|
Reversion |
| 8.6(Density-IS 7328:2020) |
- |
1200.01 |
|
Density |
| 8.4(Melt Flow rate(Temperature - 190oC,Mass 5kg)-IS 2530-1963) |
- |
900 |
|
MFI |
| 8.3(Carbon black content- IS 2530-1963) |
- |
694 |
|
CBC |
| 8.3(Carbon black content Dispersion- IS 2530-1963) |
- |
525 |
|
CBD |
| 7.4,T4 of IS 4984(wall Thickness-IS 4984-2016) |
- |
0 |
|
Dimension |
| 7.4,T3 of IS 4984(Ovality-IS 4984-2016) |
- |
0 |
|
Dimension |
| 5.2.1,T2(Melt Flow Rate (At 190°C /5kg)-IS 2530:1963) |
- |
900 |
|
MFI |
| 5.2.1,T2(Thermal Stability(Oxidation Induction Time)-IS 4984:2016(Annexure-B)) |
- |
1650 |
|
OIT |
| 5.2.1,T2("Volatile Matter- IS 4984:2016
(Annexure-C)") |
- |
900 |
|
Volatile |
| 5.2.1.1, T2(Compound Density-IS 7328:2020) |
- |
525 |
|
Density |
| 5.2.1.1, T2("Compound carbon black -IS 2530:1963
content") |
- |
694.01 |
|
CBC |
| 5.2.1.1, T2(Compound Toluene extract - Any Method) |
- |
900 |
|
Toluene |
| 5.2.1.1, T2(Compound maximum volatile matter -IS 4984:2016 (Annexure-C)) |
- |
900 |
|
Volatile matter |
| 5.2.1.1, T2(Compound ash content - Any Method) |
- |
900 |
|
Ash |
| 5.2.1.1, T2("Compound carbon black -IS 2530:1963
dispersion") |
- |
694 |
|
CBC |
| 5.3(Density of Higher olefin - IS 7328:2020) |
- |
525 |
|
Density |
| 5.3(Loading of Carbon Black - IS 2530:1963) |
- |
694 |
|
Carbon Black |
| 5.3(Ash content- Any Method) |
- |
900 |
|
Ash Content |
| 5.3(Toluene extract - Any Method) |
- |
825 |
|
Toluene |
| 5.3("Maximum volatile matter -IS 4984:2016
(Annexure-C)") |
- |
825 |
|
volatile matter |
| 6(Pipe Description - IS 14333-2022) |
- |
225 |
|
Visual |
| 8.1.1, T4(Internal Pressure creep Rupture test, Temperature - 80 oC , Test Period - 165 hrs.-IS 4984-2016 (Annexure-E)) |
- |
2249.97 |
|
165 hrs.-Internal Pressure creep Rupture test, |
| 8.1.1, T4(Internal Pressure creep Rupture test, Temperature - 80 oC , Test Period - 1000 hrs.-IS 4984-2016 (Annexure-E)) |
- |
8250 |
|
1000 hrs.-Internal Pressure creep Rupture test, |
| 8.1.2, T4(Internal Pressure creep Rupture test, Temperature - 80 oC , Test Period - 48 hrs.-IS 4984-2016 (Annexure-E)) |
- |
1200 |
|
48 hrs.-Internal Pressure creep Rupture test, |
| 8.5(Oxidation Induction Time -IS 4984:2016(Annexure-B)) |
- |
1650.01 |
|
OIT |
| 8.7("Tensile Strength for Butt Fusion - IS 4984-2016
(Annexure-G)") |
- |
975 |
|
Butt Fusion tensile |
| 8.8,T5("Tensile - IS 4984-2016
(Annexure-H)") |
- |
975 |
|
Tensile |
| 8.8,T5("Elongation -IS 4984-2016
(Annexure-H)") |
- |
0 |
|
Included in tensile |
| 8.9(Slow Crack Growth Rate{Internal Pressure creep Rupture test, Temperature - 80±1 oC , Test Pressure – 0.80MPa, Test Period - 500 hrs.-IS 4984-2016 (Annexure-E &J)) |
- |
1200 |
|
Slow Crack Growth Rate |
|
31 Dec, 2026 |
- - |
| 5577 |
CIPET. MYSURU
| 6113734
| IS 2508 (2016) |
Polyethylene films and sheets - Specification (Third Revision) |
Films |
24106.25 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 5.1.1(Appearance) |
- |
225 |
|
Test charges after 25% BIS Discount from our actual Approved charges |
| 5.1.2(Film Form) |
- |
0 |
|
Test charges included In Appearance |
| 5.1.3(Odour) |
- |
0 |
|
Test charges included In Appearance |
| 5.1.4(Density, Cl.5 of IS 13360(Part-3/Section-1)) |
- |
375 |
|
Test charges after 25% BIS Discount from our actual Approved charges |
| 5.1.5(Melt Flow Index. Cl 6, 7 of IS 13360(Part-4/Section-1)) |
- |
825 |
|
Test charges after 25% BIS Discount from our actual Approved charges |
| 5.1.6a(Carbon Black Content, Annex-A) |
- |
693.75 |
|
Test charges after 25% BIS Discount from our actual Approved charges |
| 5.1.6b(Ash Content, Annex-A) |
- |
600 |
|
Test charges after 25% BIS Discount from our actual Approved charges |
| 5.1.6c(Carbon Black Dispersion, Cl.16 of IS 2530) |
- |
525 |
|
Test charges after 25% BIS Discount from our actual Approved charges |
| 5.2.2(Tolerance on Thickness, Annex-A) |
- |
187.50 |
|
Test charges after 25% BIS Discount from our actual Approved charges |
| 6.1, Table 1(Tensile strength at break. A) Machine Direction. IS 13360 (Part 5/Sec 1)) |
- |
1075 |
|
Test charges after 25% BIS Discount from our actual Approved charges |
| 6.1, Table 1(Tensile strength at break. B) Transverse Direction. IS 13360 (Part 5/Sec 3)) |
- |
1075 |
|
Test charges after 25% BIS Discount from our actual Approved charges |
| 6.1, Table 1(Ageing test at (70-1)c for 7 days , cl 4 IS 7016 ) |
- |
525 |
|
Test charges after 25% BIS Discount from our actual Approved charges |
| 6.1, Table 1(Elongation at break ,A) Machine direction .IS 13360(Part-5/sec-1) ) |
- |
0 |
|
Test charges included In Tensile properties |
| 6.1, Table 1(Elongation at break ,B) Cross-machine direction..IS 13360(Part-5/sec-3) ) |
- |
0 |
|
Test charges included In Tensile properties |
| 6.1, Table 1(Dartimpact strength Method B of IS 13360 (Part-5/sec-6) ) |
- |
637.50 |
|
Test charges after 25% BIS Discount from our actual Approved charges |
| 6.1, Table 1(Tear resistence. A) Machine direction Annex B) |
- |
825 |
|
Test charges after 25% BIS Discount from our actual Approved charges |
| 6.1, Table 1(Tear resistence. B) Transverse direction ) |
- |
825 |
|
Test charges after 25% BIS Discount from our actual Approved charges |
| 7.1. Table 2(Tensile strength at break A) Machine direction IS 13360 (Part-5/sec-1) ) |
- |
1075 |
|
Test charges after 25% BIS Discount from our actual Approved charges |
| 7.1. Table 2(Tensile strength at break,B) Crosse machine direction IS 13360 (Part-5/sec-3) ) |
- |
1075 |
|
Test charges after 25% BIS Discount from our actual Approved charges |
| 7.1. Table 2(Ageing test at (70-1)c for 7 days , cl 4 IS 7016 ) |
- |
525 |
|
Test charges after 25% BIS Discount from our actual Approved charges |
| 7.1. Table 2(Elongation at break , A) Machine direction IS 13360 (Part-5/sec-3) IS 13360 (Part-5/sec-1) ) |
- |
0 |
|
Test charges included In Tensile properties |
| 7.1. Table 2(Elongation at break , A) Transverse direction IS 13360 (Part-5/sec-3) ) |
- |
0 |
|
Test charges included In Tensile properties |
| 7.1. Table 2(Dart impact strenght , Method A of IS 3360 (Part-5/sec-6) ) |
- |
637.50 |
|
Test charges after 25% BIS Discount from our actual Approved charges |
| 8.1, Table 3(Tensile properties ,A) Yield strenght . IS 3360 (Part-5/sec-1) and IS 3360 (Part-5/sec-3) Test condition- specimen type 5 and test speed 51 mm/min do) |
- |
1075 |
|
Test charges after 25% BIS Discount from our actual Approved charges |
| 8.1, Table 3(Tensile properties , B) Break strenght . IS 3360 (Part-5/sec-1) and IS 3360 (Part-5/sec-3) Test condition- specimen type 5 and test speed 51 mm/min do) |
- |
1075 |
|
Test charges after 25% BIS Discount from our actual Approved charges |
| 8.1, Table 3(Tensile properties ,C) Yield elongation . IS 3360 (Part-5/sec-1) and IS 3360 (Part-5/sec-3) Test condition- specimen type 5 and test speed 51 mm/min do) |
- |
1075 |
|
Test charges after 25% BIS Discount from our actual Approved charges |
| 8.1, Table 3(Tensile properties ,D) Break elongation . IS 3360 (Part-5/sec-1) and IS 3360 (Part-5/sec-3) Test condition- specimen type 5 and test speed 51 mm/min do) |
- |
1075 |
|
Test charges after 25% BIS Discount from our actual Approved charges |
| 8.1, Table 3(Tear resistance , Annex B) |
- |
825 |
|
Test charges after 25% BIS Discount from our actual Approved charges |
| 8.1, Table 3(Puncture resistance , Annex C) |
- |
1075 |
|
Test charges after 25% BIS Discount from our actual Approved charges |
| 9.1, Table 4(Tensile properties ,A) Yield strenght . IS 3360 (Part-5/sec-1) and IS 3360 (Part-5/sec-3) Test condition- specimen type 5 and test speed 51 mm/min do) |
- |
1075 |
|
Test charges after 25% BIS Discount from our actual Approved charges |
| 9.1, Table 4(Tensile properties , B) Break strenght . IS 3360 (Part-5/sec-1) and IS 3360 (Part-5/sec-3) Test condition- specimen type 5 and test speed 51 mm/min do) |
- |
1075 |
|
Test charges after 25% BIS Discount from our actual Approved charges |
| 9.1, Table 4(Tensile properties ,C) Yield elongation . IS 3360 (Part-5/sec-1) and IS 3360 (Part-5/sec-3) Test condition- specimen type 5 and test speed 51 mm/min do) |
- |
1075 |
|
Test charges after 25% BIS Discount from our actual Approved charges |
| 9.1, Table 4(Tensile properties ,D) Break elongation . IS 3360 (Part-5/sec-1) and IS 3360 (Part-5/sec-3) Test condition- specimen type 5 and test speed 51 mm/min do) |
- |
1075 |
|
Test charges after 25% BIS Discount from our actual Approved charges |
| 9.1, Table 4(Tear resistance , Annex B) |
- |
825 |
|
Test charges after 25% BIS Discount from our actual Approved charges |
| 9.1, Table 4(Puncture resistance , Annex C) |
- |
1075 |
|
Test charges after 25% BIS Discount from our actual Approved charges |
| 5.2.1.2(Nominal width) |
- |
0 |
|
- |
|
31 Dec, 2026 |
- - |
| 5578 |
Planet Electro Labs Private Limited, Wazirpur
| 8185226
| IS/IEC 60947 : Part 5 : Sec 2 (2019) |
LLow-Voltage Switchgear and Controlgear Part 5 Control Circuit Devices and Switching Elements Section 2 Proximity Switches ( First Revision ) |
- |
2200000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 5.1(General) |
- |
2000 |
|
- |
| 5.2(Operating conditions) |
- |
10000 |
|
- |
| 6.2(Marking) |
- |
5000 |
|
- |
| 5.3(Rated and limiting values for the proximity switch and switching element(s)) |
- |
35000 |
|
- |
| 6.4(Environmental information) |
- |
5000 |
|
- |
| 7(Normal service, mounting and transport conditions) |
- |
5000 |
|
- |
| 8(Constructional and performance requirements) |
- |
180000 |
|
- |
| 8.1.1.2(Glow-wire testing) |
- |
10000 |
|
- |
| 8.1.1.3(Test based on flammability categor) |
- |
45000 |
|
- |
| 8.1.2(Current-carrying parts and their connections) |
- |
35000 |
|
- |
| 8.1.3(Clearances and creepage distances) |
- |
5000 |
|
- |
| 8.1.7.1(Constructional requirements) |
- |
45000 |
|
- |
| 8.1.9(Provisions for protective earthing) |
- |
35000 |
|
- |
| 8.1.10(Degree of protection) |
- |
45000 |
|
- |
| 8.1.11(Requirements for proximity switches with integrally connected cables) |
- |
65000 |
|
- |
| 8.2(Performance requirements) |
- |
125000 |
|
- |
| 8.2.2(Temperature-rise) |
- |
35000 |
|
- |
| 8.2.3(Dielectric properties) |
- |
25000 |
|
- |
| 8.2.3.2(Impulse withstand voltage) |
- |
65000 |
|
- |
| 8.2.4(Ability to make and break under normal load and abnormal load conditions) |
- |
125000 |
|
- |
| 8.2.5(Conditional short-circuit current) |
- |
125000 |
|
- |
| 8.3(Physical dimensions) |
- |
5000 |
|
- |
| 8.4(Shock and vibration and special environmental conditions) |
- |
65000 |
|
- |
| 9.2(Compliance with constructional requirements) |
- |
45000 |
|
- |
| 9.2.2.1(Test of resistance to abnormal heat and fire) |
- |
45000 |
|
- |
| 9.2.2.1.2(Flammability, hot wire ignition and arc ignition tests (on materials)) |
- |
85000 |
|
- |
| 9.3.3.4(Dielectric properties) |
- |
25000 |
|
- |
| 9.3.3.4.5(Impulse withstand voltage test) |
- |
35000 |
|
- |
| 9.3.3.5(Making and breaking capacities) |
- |
125000 |
|
- |
| B.9.1.2.3(Cable tests) |
- |
35000 |
|
- |
| B.9.1.2.4(Change of temperature test) |
- |
55000 |
|
- |
| B.9.1.2.5(Impact test) |
- |
25000 |
|
- |
| B.9.1.2.6(Damp heat, cyclic test) |
- |
75000 |
|
- |
| B.9.1.2.7(Dielectric test after stresses) |
- |
25000 |
|
- |
| C.9.1.2(Pull test) |
- |
25000 |
|
- |
| C.9.1.3(Torque test) |
- |
25000 |
|
- |
| C.9.1.4(Push test) |
- |
25000 |
|
- |
| C.9.1.5(Bend test) |
- |
15000 |
|
- |
| 9.3.4(Performance under short-circuit current conditions) |
- |
125000 |
|
- |
| 9.4(Testing of operating distances) |
- |
10000 |
|
- |
| 9.5(Testing for the frequency of operating cycles) |
- |
55000 |
|
- |
| 8.1.10(Degree of protection) |
- |
45000 |
|
- |
| 9.3.3.2(Operating limits) |
- |
125000 |
|
- |
| 9.3.3.3(Temperature-rise) |
- |
45000 |
|
- |
| E.8(Construction and performance requirements) |
- |
185000 |
|
- |
|
08 May, 2028 |
- Included w.e.f 26.12.2025
Exclusion: Cl. No. 8.4.1, Cl. No. 8.4.2, Cl. No. 9.4, Cl. No. 9.5, Cl. No. 8.2.6, Cl. No. 8.2.5, Cl. No. 9.3.4, Cl. No. E.9.1, Cl. No. 8.1.15 |
| 5579 |
Classic Instrumentation Pvt. Ltd. (8135126), Noida
| 8135126
| IS 16103 : Part 1 (2012) |
Led modules for general lighting: Part 1 safety requirements |
- |
40000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 7(Marking) |
- |
2000 |
|
- |
| 8(Terminals) |
- |
30000 |
|
- |
| 9(PROVISION FOR EARTHING) |
- |
3500 |
|
- |
| 10(Protection against accidental contact with live parts) |
- |
3500 |
|
- |
| 11(Mositure Resistance and Insulation) |
- |
4000 |
|
- |
| 12(Electric Strength) |
- |
3000 |
|
- |
| 13(Fault conditions) |
- |
3000 |
|
- |
| 15(Construction) |
- |
3000 |
|
- |
| 16(Creepage distance and clearances) |
- |
3000 |
|
- |
| 17(Screws, current carrying parts and connections) |
- |
3000 |
|
- |
| 18(Resistance to heat, fire and tracking) |
- |
3000 |
|
- |
| 19(Resistance to corrosion) |
- |
3000 |
|
- |
| 21(Heat management) |
- |
3000 |
|
- |
|
23 Oct, 2028 |
- Included w.e.f 16.07.2025 |
| 5580 |
Arihant Analytical Laboratory Pvt. Ltd., Sonipat
| 9167906
| IS 1660 (2024) |
Wrought and Cast Aluminium Utensils Specification ( Second Revision ) |
All Type |
25000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl-3.1.1, 3.1.2(Minimum Thickness of Sheet) |
- |
25000 |
|
- |
| Cl-3.1.3, Table-2(Minimum Thickness at the Bottom) |
- |
25000 |
|
- |
| Cl-3.1.3, Table-2(Minimium Thickness of Wall at the Top Edge) |
- |
25000 |
|
- |
| Cl-3.1.3, Table-2(Minimum Cover Thickness) |
- |
25000 |
|
- |
| Cl-4.1(Main body of utensil) |
- |
25000 |
|
- |
| Cl-4.1(Cast cookware) |
- |
25000 |
|
- |
| Cl-4.1(Other aluminum components and parts) |
- |
25000 |
|
- |
| Cl-4.1.1(Lids (material)) |
- |
25000 |
|
- |
| Cl-4.1.1(Minimum thickness of lid) |
- |
25000 |
|
- |
| Cl-4.1.2(Minimum thickness of glass) |
- |
25000 |
|
- |
| Cl-4.1.2(Material of rim) |
- |
25000 |
|
- |
| Cl-4.1.2(Minimum thickness of rim) |
- |
25000 |
|
- |
| Cl-4.2(Material of strips) |
- |
25000 |
|
- |
| Cl-4.2(Stainless steel handles, rivets and fittings) |
- |
25000 |
|
- |
| Cl-4.3(Clips of lunch box) |
- |
25000 |
|
- |
| Cl-4.3(Clips of lunch box) |
- |
25000 |
|
- |
| Cl-4.3(Rivets used in lunch box) |
- |
25000 |
|
- |
| Cl-4.4(Screws, studs/nuts, and locking loop) |
- |
25000 |
|
- |
| Cl-4.5(Rivets for fixing of handles) |
- |
25000 |
|
- |
| Cl-4.5(Material of cap) |
- |
25000 |
|
- |
| Cl-4.6(Strips used for flame guards) |
- |
25000 |
|
- |
| Cl-4.6(stainless steel) |
- |
25000 |
|
- |
| Cl-5(Fabrication) |
- |
25000 |
|
- |
| Cl-6(Shape and Dimensions) |
- |
25000 |
|
- |
| Cl-7.1(Handles, when fitted) |
- |
25000 |
|
- |
| Cl-7.2(Handles) |
- |
25000 |
|
- |
| Cl-7.3 (Cl- 4.1 of IS 13395)(Construction) |
- |
25000 |
|
- |
| Cl-7.3 (Cl- 4.2 of IS 13395)(Materials) |
- |
25000 |
|
- |
| Cl-7.3 (Cl- 4.3 of IS 13395)(Selection and Size) |
- |
25000 |
|
- |
| Cl-7.3 (Cl- 4.4 of IS 13395)(Position of Handle and Knob with Respect to Cookware) |
- |
25000 |
|
- |
| Cl-7.3 (Cl- 4.5 of IS 13395)(Attachment to Cookware) |
- |
25000 |
|
- |
| Cl-7.3 (Cl- 5.2 of IS 13395)(Bending Strength) |
- |
25000 |
|
- |
| Cl-7.3 (Cl- 5.3 of IS 13395)(Torque Strength) |
- |
25000 |
|
- |
| Cl-7.3 (Cl- 5.4 of IS 13395)(Impact Strength) |
- |
25000 |
|
- |
| Cl-7.3 (Cl- 5.5 of IS 13395)(Fatigue Resistance) |
- |
25000 |
|
- |
| Cl-7.3 (Cl- 5.6 of IS 13395)(Leakage) |
- |
25000 |
|
- |
| Cl-7.3 (Cl- 5.7 of IS 13395)(Thermal Insulation) |
- |
25000 |
|
- |
| Wrought and Cast Aluminium Utensils — Specification(Heat Resistance) |
- |
25000 |
|
- |
| Cl-7.3 (Cl- 5.9 of IS 13395)(Washing Resistance (Type Test)) |
- |
25000 |
|
- |
| Cl-7.3 (Cl- 5.10 of IS 13395)(Burning Resistance) |
- |
25000 |
|
- |
| Cl-8(Workmanship and Finish) |
- |
25000 |
|
- |
| Cl-8.3(Utensils, if anodized, fully or partially) |
- |
25000 |
|
- |
| Cl-8.3(Minimum nominal thickness) |
- |
25000 |
|
- |
| Cl-8.3(Thickness of hard anodized) |
- |
25000 |
|
- |
| Cl-8.3(Finish and appearance of hard anodized) |
- |
25000 |
|
- |
| Cl-8.3(Abrasion resistance of hard anodized) |
- |
25000 |
|
- |
| Cl-8.3(Colour of hard anodized) |
- |
25000 |
|
- |
| Cl-8.3(Hardness of hard anodized) |
- |
25000 |
|
- |
| Wrought and Cast Aluminium Utensils — Specification(Lid of the cookware) |
- |
25000 |
|
- |
| Cl-8.5(Non-stick unreinforced PTFE) |
- |
25000 |
|
- |
| Cl-8.6(Ceramic coating) |
- |
25000 |
|
- |
| Cl-8.7(The thickness test, adhesion test) |
- |
25000 |
|
- |
| Cl-8.7(Minimum thickness of coating) |
- |
25000 |
|
- |
| Cl-8.7.1(Dry heat the cookware) |
- |
25000 |
|
- |
| Cl-8.8(Requirements of PTFE) |
- |
25000 |
|
- |
| Cl-8.9(Material for induction plate) |
- |
25000 |
|
- |
| Cl-8.9(Test for Induction compatible base) |
- |
25000 |
|
- |
| Cl-8.10.1(Tests for Lunch Boxes- Performance Test) |
- |
25000 |
|
- |
| Cl-8.10.1(Tests for Lunch Boxes- Performance Test) |
- |
25000 |
|
- |
| Cl-8.10.2(Tests for Lunch Boxes- Ground Nut Oil Test for Leakage) |
- |
25000 |
|
- |
| Cl-8.11.1(Test(s) on Tempered Glass Lid- Fragmentation Test) |
- |
25000 |
|
- |
| Cl-8.11.2(Test(s) on Tempered Glass Lid-Ball Drop Test) |
- |
25000 |
|
- |
| Cl-8.11.3(Test(s) on Tempered Glass Lid- Thermal Shock Test) |
- |
25000 |
|
- |
| Cl-8.11.4(Test(s) on Tempered Glass Lid- Free Fall Test) |
- |
25000 |
|
- |
| Cl-9.1(Normal Capacity) |
- |
25000 |
|
- |
| Cl-9.2(Normal Capacity of internal diameter) |
- |
25000 |
|
- |
|
02 Jun, 2027 |
- Included w.e.f.29.07.2025 |