| 5971 |
SKC COMPLIANCE LAB PRIVATE LIMITED, MAHADEVPURA
| 6170406
| IS 16333 : Part 3 (2022) |
Mobile phone handsets: Part 3 Indian language support for mobile phone handsets - Specific requirements(Second Revision) |
- |
15000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 5.1(Inputting of text) |
- |
5000 |
|
- |
| 5.2(Message Readability) |
- |
3000 |
|
- |
| 6(Marking) |
- |
4000 |
|
- |
| "Cl.6.1 "(Marking) |
- |
1000 |
|
- |
| "Cl.6.2 "(BIS Certification Marking) |
- |
1000 |
|
- |
| 6(Marking) |
- |
1000 |
|
- |
| 5(Tests) |
- |
0 |
|
- |
| 4(Requirements) |
- |
0 |
|
- |
| 5.1(Inputting of text) |
- |
0 |
|
- |
| 5.2(Message Readability) |
- |
0 |
|
- |
| 6(Marking) |
- |
0 |
|
- |
| "Cl.6.1 "(Marking) |
- |
0 |
|
- |
| "Cl.6.2 "(BIS Certification Marking) |
- |
0 |
|
- |
| 6(Marking) |
- |
0 |
|
- |
| 5(Tests) |
- |
0 |
|
- |
| 4(Requirements) |
- |
0 |
|
- |
| 5.1(Inputting of text) |
- |
0 |
|
- |
| 5.2(Message Readability) |
- |
0 |
|
- |
| 6(Marking) |
- |
0 |
|
- |
| "Cl.6.1 "(Marking) |
- |
0 |
|
- |
| "Cl.6.2 "(BIS Certification Marking) |
- |
0 |
|
- |
| 6(Marking) |
- |
0 |
|
- |
| 5(Tests) |
- |
0 |
|
- |
| 4(Requirements) |
- |
0 |
|
- |
|
24 May, 2028 |
- Included.w.e.f.26.12.2024 |
| 5972 |
Classic Testing & Research Centre (B17), Noida
| 8180826
| IS 302 : Part 2 : Sec 201 (2008) |
Safety of household and similar electrical appliances: Part 2 particular requirements: Sec 201 electric immersion water heaters (First Revision) |
- |
14500 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl.6 of IS 302-‐2-‐201:2008(Classification) |
- |
500 |
|
- |
| Cl.7 of IS 302-2-201:2008(Marking and Instruction ) |
- |
500 |
|
- |
| Cl.7 of IS 302-2-201:2008(Marking and Instruction ) |
- |
500 |
|
- |
| Cl.7 of IS 302-2-201:2008(Marking and Instruction ) |
- |
500 |
|
- |
| Cl.7 of IS 302-2-201:2008(Marking and Instruction ) |
- |
500 |
|
- |
| Cl.7 of IS 302-2-201:2008(Marking and Instruction ) |
- |
500 |
|
- |
| Cl.7 of IS 302-2-201:2008(Marking and Instruction ) |
- |
500 |
|
- |
| Cl.7 of IS 302-2-201:2008(Marking and Instruction ) |
- |
500 |
|
- |
| Cl.7 of IS 302-2-201:2008(Marking and Instruction ) |
- |
500 |
|
- |
| Cl.7 of IS 302-2-201:2008(Marking and Instruction ) |
- |
500 |
|
- |
| Cl.7 of IS 302-2-201:2008(Marking and Instruction ) |
- |
500 |
|
- |
| Cl.7 of IS 302-2-201:2008(Marking and Instruction ) |
- |
500 |
|
- |
| Cl.7 of IS 302-2-201:2008(Marking and Instruction ) |
- |
500 |
|
- |
| Cl.7 of IS 302-2-201:2008(Marking and Instruction ) |
- |
500 |
|
- |
| Cl.7 of IS 302-2-201:2008(Marking and Instruction ) |
- |
500 |
|
- |
| Cl.7 of IS 302-2-201:2008(Marking and Instruction ) |
- |
500 |
|
- |
| Cl.7 of IS 302-2-201:2008(Marking and Instruction ) |
- |
500 |
|
- |
| Cl.7 of IS 302-2-201:2008(Marking and Instruction ) |
- |
500 |
|
- |
| Cl.7 of IS 302-2-201:2008(Marking and Instruction ) |
- |
500 |
|
- |
| Cl.7 of IS 302-2-201:2008(Marking and Instruction ) |
- |
500 |
|
- |
| Cl.7 of IS 302-2-201:2008(Marking and Instruction ) |
- |
500 |
|
- |
| Cl.8 of IS 302‐2-201: 2008(Protection Against Access to Live Parts) |
- |
1000 |
|
- |
| Cl.10 of IS 302‐2‐201:2008(Power Input and Current ) |
- |
1000 |
|
- |
| Cl.11 of IS 302-2201: 2008(Heating) |
- |
1000 |
|
- |
| Cl.11 of IS 302-2201: 2008(Heating) |
- |
1000 |
|
- |
| Cl.11 of IS 302-2201: 2008(Heating) |
- |
1000 |
|
- |
| Cl.11 of IS 302-2201: 2008(Heating) |
- |
1000 |
|
- |
| Cl.11 of IS 302-2201: 2008(Heating) |
- |
1000 |
|
- |
| Cl.11 of IS 302-2201: 2008(Heating) |
- |
1000 |
|
- |
| Cl.11 of IS 302-2201: 2008(Heating) |
- |
1000 |
|
- |
| Cl.11 of IS 302-2201: 2008(Heating) |
- |
1000 |
|
- |
| Cl.11 of IS 302-2201: 2008(Heating) |
- |
1000 |
|
- |
| Cl.11 of IS 302-2201: 2008(Heating) |
- |
1000 |
|
- |
| Cl.11 of IS 302-2201: 2008(Heating) |
- |
1000 |
|
- |
| Cl.13 of IS 302-2-201: 2008(Leakage Current & Electric Strength at Operating Temperature) |
- |
1000 |
|
- |
| Cl.14 of IS 302‐2-201:2008(Transient Over Voltages ) |
- |
1000 |
|
- |
| Cl.15 of IS 302-2-201:2008(Moisture Resistance ) |
- |
1000 |
|
- |
| Cl.15 of IS 302-2-201:2008(Moisture Resistance ) |
- |
1000 |
|
- |
| Cl.16 of IS 302-2-201:2008(Leakage Current & Electric Strength) |
- |
1000 |
|
- |
| Cl.16 of IS 302-2-201:2008(Leakage Current & Electric Strength) |
- |
1000 |
|
- |
| Cl.17 of IS 302‐2-201: 2008(Overload Protection of Transformers & Associated Circuits) |
- |
1000 |
|
- |
| Cl.19 of IS 302‐2-201: 2008(Abnormal Operation ) |
- |
1000 |
|
- |
| Cl.19 of IS 302‐2-201: 2008(Abnormal Operation ) |
- |
1000 |
|
- |
| Cl.19 of IS 302‐2-201: 2008(Abnormal Operation ) |
- |
1000 |
|
- |
| Cl.19 of IS 302‐2-201: 2008(Abnormal Operation ) |
- |
1000 |
|
- |
| Cl.20 of IS 302-2-201: 2008(Stability & Mechanical Hazards) |
- |
1000 |
|
- |
| Cl.21 of IS 302-2-201: 2008(Mechanical Strength ) |
- |
1000 |
|
- |
| Cl.21 of IS 302-2-201: 2008(Mechanical Strength ) |
- |
1000 |
|
- |
| Cl.21 of IS 302-2-201: 2008(Mechanical Strength ) |
- |
1000 |
|
- |
| Cl.22 of IS 302-2-201: 2008(Construction) |
- |
1000 |
|
- |
| Cl.23 of 302-2-201:2008(Internal Wiring ) |
- |
1000 |
|
- |
| Cl.23 of 302-2-201:2008(Internal Wiring ) |
- |
1000 |
|
- |
| Cl.23 of 302-2-201:2008(Internal Wiring ) |
- |
1000 |
|
- |
| Cl.23 of 302-2-201:2008(Internal Wiring ) |
- |
1000 |
|
- |
| Cl.23 of 302-2-201:2008(Internal Wiring ) |
- |
1000 |
|
- |
| Cl.23 of 302-2-201:2008(Internal Wiring ) |
- |
1000 |
|
- |
| Cl.23 of 302-2-201:2008(Internal Wiring ) |
- |
1000 |
|
- |
| Cl.23 of 302-2-201:2008(Internal Wiring ) |
- |
1000 |
|
- |
| Cl.23 of 302-2-201:2008(Internal Wiring ) |
- |
1000 |
|
- |
| Cl.24 of IS 302-2-201: 2008(Component) |
- |
1000 |
|
- |
| Cl.24 of IS 302-2-201: 2008(Component) |
- |
1000 |
|
- |
| Cl.24 of IS 302-2-201: 2008(Component) |
- |
1000 |
|
- |
| Cl.24 of IS 302-2-201: 2008(Component) |
- |
1000 |
|
- |
| Cl.24 of IS 302-2-201: 2008(Component) |
- |
1000 |
|
- |
| Cl.24 of IS 302-2-201: 2008(Component) |
- |
1000 |
|
- |
| Cl.24 of IS 302-2-201: 2008(Component) |
- |
1000 |
|
- |
| Cl.24 of IS 302-2-201: 2008(Component) |
- |
1000 |
|
- |
| Cl.24 of IS 302-2-201: 2008(Component) |
- |
1000 |
|
- |
| Cl.25 of IS 302-2-201: 2008(Supply Connection and External Flexible Cords) |
- |
1000 |
|
- |
| Cl.25 of IS 302-2-201: 2008(Supply Connection and External Flexible Cords) |
- |
1000 |
|
- |
| Cl.25 of IS 302-2-201: 2008(Supply Connection and External Flexible Cords) |
- |
1000 |
|
- |
| Cl.25 of IS 302-2-201: 2008(Supply Connection and External Flexible Cords) |
- |
1000 |
|
- |
| Cl.25 of IS 302-2-201: 2008(Supply Connection and External Flexible Cords) |
- |
1000 |
|
- |
| Cl.25 of IS 302-2-201: 2008(Supply Connection and External Flexible Cords) |
- |
1000 |
|
- |
| Cl.25 of IS 302-2-201: 2008(Supply Connection and External Flexible Cords) |
- |
1000 |
|
- |
| Cl.25 of IS 302-2-201: 2008(Supply Connection and External Flexible Cords) |
- |
1000 |
|
- |
| Cl.25 of IS 302-2-201: 2008(Supply Connection and External Flexible Cords) |
- |
1000 |
|
- |
| Cl.25 of IS 302-2-201: 2008(Supply Connection and External Flexible Cords) |
- |
1000 |
|
- |
| Cl.25 of IS 302-2-201: 2008(Supply Connection and External Flexible Cords) |
- |
1000 |
|
- |
| Cl.25 of IS 302-2-201: 2008(Supply Connection and External Flexible Cords) |
- |
1000 |
|
- |
| Cl.25 of IS 302-2-201: 2008(Supply Connection and External Flexible Cords) |
- |
1000 |
|
- |
| Cl.25 of IS 302-2-201: 2008(Supply Connection and External Flexible Cords) |
- |
1000 |
|
- |
| Cl.25 of IS 302-2-201: 2008(Supply Connection and External Flexible Cords) |
- |
1000 |
|
- |
| Cl.25 of IS 302-2-201: 2008(Supply Connection and External Flexible Cords) |
- |
1000 |
|
- |
| Cl.25 of IS 302-2-201: 2008(Supply Connection and External Flexible Cords) |
- |
1000 |
|
- |
| Cl.25 of IS 302-2-201: 2008(Supply Connection and External Flexible Cords) |
- |
1000 |
|
- |
| Cl.25 of IS 302-2-201: 2008(Supply Connection and External Flexible Cords) |
- |
1000 |
|
- |
| Cl.25 of IS 302-2-201: 2008(Supply Connection and External Flexible Cords) |
- |
1000 |
|
- |
| Cl.26 of IS 302-2-201: 2008(Terminals for External Conductors) |
- |
1000 |
|
- |
| Cl.27 of IS 302-2-201: 2008(Provision for Earthing ) |
- |
1000 |
|
- |
| Cl.27 of IS 302-2-201: 2008(Provision for Earthing ) |
- |
1000 |
|
- |
| Cl.27 of IS 302-2-201: 2008(Provision for Earthing ) |
- |
1000 |
|
- |
| Cl.27 of IS 302-2-201: 2008(Provision for Earthing ) |
- |
1000 |
|
- |
| Cl.27 of IS 302-2-201: 2008(Provision for Earthing ) |
- |
1000 |
|
- |
| Cl.27 of IS 302-2-201: 2008(Provision for Earthing ) |
- |
1000 |
|
- |
| Cl.28 of IS 302-2-201: 2008(Screws & Connections ) |
- |
1000 |
|
- |
| Cl.29 of IS 302-2‐201:2008(Clearances, Creepage Distances and Solid Insulation ) |
- |
1000 |
|
- |
| Cl.30 of IS 302-2‐201:2008(Resistance to Heat and Fire ) |
- |
1000 |
|
- |
| Cl.31 of IS 302-2-201:2008(Resistance of Rusting ) |
- |
1000 |
|
- |
| Cl.32 of IS 302-2-201:2008(Radiation, Toxicity and Similar Hazards) |
- |
1000 |
|
- |
| 19.11.4.7(Harmonics) |
- |
1000 |
|
- |
| 19.11.4.6(Class 3 Voltage dips and interruptions) |
- |
1000 |
|
- |
| 19.11.4.4(Surge immunity test) |
- |
1000 |
|
- |
| 19.11.4.3(Fast transient bursts) |
- |
1000 |
|
- |
| 19.11.4.1(Electrostatic discharges) |
- |
1000 |
|
- |
| 4(GENERAL REQUIREMENTS) |
- |
500 |
|
- |
| 5(GENERAL CONDITIONS FOR THE TESTS) |
- |
500 |
|
- |
|
15 Oct, 2027 |
- Included w.e.f.12.12.2024
Exclusion
CL 19.11.4.2 (Radiated fields)
CL 19.11.4.5 (Immunity to conducted discharges) |
| 5973 |
Global Testing Laboratory Private limited, Ghaziabad
| 8184306
| IS 1554 : Part 1 (1988) |
Specification for pvc insulated (Heavy Duty) electric cables: Part 1 for working voltages up to and including 1100 v (Third Revision) |
- |
11500 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 3.1(MATERIALS : CONDUCTOR) |
- |
500 |
|
- |
| 4.1.1(INSULATION : General Purjose Insulaiion) |
- |
500 |
|
- |
| 4.1.2(INSULATION : Heat Resisting Insulation) |
- |
500 |
|
- |
| 5.1(MATERIALS : FILLER AND INNER SHEATH) |
- |
500 |
|
- |
| 5.2(MATERIALS : FILLER AND INNER SHEATH) |
- |
500 |
|
- |
| 6.1(MATERIALS : ARMGURING) |
- |
500 |
|
- |
| 6.2(MATERIALS : ARMGURING) |
- |
500 |
|
- |
| 7.1.1(OUTER SHEATH : For Cables with General Purpose InsuIafion) |
- |
500 |
|
- |
| 7.1.2(OUTER SHEATH : For Cables with Heat Resisting InsuIalion) |
- |
500 |
|
- |
| 8.1(CONSTRUCTION : CONDUCTOR) |
- |
500 |
|
- |
| 8.2(CONSTRUCTION : CONDUCTOR) |
- |
500 |
|
- |
| 9.1(INSULATION ) |
- |
500 |
|
- |
| 9.2(INSULATION : Thickness of Insulation) |
- |
1000 |
|
- |
| 9.3(INSULATION :Tolerance on Thickness of Insulation) |
- |
1000 |
|
- |
| 9.4(INSULATION : Application of Insulation) |
- |
500 |
|
- |
| 10.1(CORE IDENTIFICATION) |
- |
500 |
|
- |
| 10.2(CORE IDENTIFICATION) |
- |
500 |
|
- |
| 10.3(CORE IDENTIFICATION) |
- |
500 |
|
- |
| 10.3.1(Arrangement of Marking) |
- |
500 |
|
- |
| 11.1(LAYING UP OF CORES) |
- |
500 |
|
- |
| 11.2(LAYING UP OF CORES) |
- |
500 |
|
- |
| 12.1(INNER SHEATH) |
- |
500 |
|
- |
| 12.2(INNER SHEATH) |
- |
500 |
|
- |
| 12.3(INNER SHEATH :Thickness of Inner Sheath) |
- |
1000 |
|
- |
| 12.3.1(INNER SHEATH :Thickness of Inner Sheath) |
- |
1000 |
|
- |
| 13.1.1(ARMOURING : Application) |
- |
500 |
|
- |
| 13.1.2(Armouring: Coverage ) |
- |
1000 |
|
- |
| 13.1.3(ARMOURING : Direction of lay ) |
- |
500 |
|
- |
| 13.1.4(ARMOURING : Application) |
- |
500 |
|
- |
| 13.2(ARMOURING : Type of Armour) |
- |
500 |
|
- |
| 13.2.1(ARMOURING : Type of Armour) |
- |
500 |
|
- |
| 13.3(Armouring : Dimensions -Wire Diameter) |
- |
500 |
|
- |
| 13.3(Armouring : Dimensions -Formed wire ) |
- |
500 |
|
- |
| 13.4(ARMOURING : Joints) |
- |
500 |
|
- |
| 13.5.1(ARMOURING : Resistance) |
- |
1000 |
|
- |
| 13.5.2(ARMOURING : Resistance) |
- |
1000 |
|
- |
| 13.6 a)(ARMOURING: Tensile Strength) |
- |
1000 |
|
- |
| 13.6 b)(ARMOURING: Elongation ) |
- |
1000 |
|
- |
| 13.6 c)(ARMOURING: Torsion Test (For round wire ) ) |
- |
1000 |
|
- |
| 13.6 d)(ARMOURING: Winding Test(For formed wire)) |
- |
500 |
|
- |
| 13.6 e)(ARMOURING: Uniformity of zinc coating) |
- |
500 |
|
- |
| 13.6 f)(ARMOURING: Mass of zinc coating ) |
- |
500 |
|
- |
| 13.6 g)(ARMOURING: Resistivity) |
- |
1000 |
|
- |
| 14.1(OUTER SHEATH) |
- |
500 |
|
- |
| 14.2(OUTER SHEATH) |
- |
500 |
|
- |
| 14.3(OUTER SHEATH : Colour ) |
- |
500 |
|
- |
| 14.4.1(Thickness of Outer Sheath : Unarmowed Cables) |
- |
1000 |
|
- |
| 14.4.2(Thickness of Outer Sheath : Armoured Cables) |
- |
1000 |
|
- |
| 15.1 a) 1)(Tests on conductor : Annealing test ( for copper )) |
- |
1000 |
|
- |
| 15.1 a) 2)(Tensile test (for aluminium) - Before stranding ) |
- |
1000 |
|
- |
| 15.1 a) 2)(Tensile test (for aluminium) - After stranding ) |
- |
1000 |
|
- |
| 15.1 a) 3)(Tests on conductor : Wrapping test ( for aluminium )) |
- |
500 |
|
- |
| 15.1 a) 4)(Tests on conductor : Conductor resistance test) |
- |
1000 |
|
- |
| 15.1 a) 4)(Resistance test - Neutral conductor ) |
- |
1000 |
|
- |
| 15.1 d)1)(Phyaical tests for insulation : Tensile Test) |
- |
1000 |
|
- |
| 15.1 d)1)(Phyaical tests for insulation : Elongation ) |
- |
1000 |
|
- |
| 15.1 d)1)(Physical tests for sheath : Tensile stregth ) |
- |
1000 |
|
- |
| 15.1 d)1)(Physical tests for sheath : Elongation ) |
- |
1000 |
|
- |
| 15.1 d)2)(Phyaical tests for insulation- Ageing in air Oven : Tensile Test) |
- |
2000 |
|
- |
| 15.1 d)2)(Phyaical tests for insulation - Ageing in air oven : Elongation ) |
- |
2000 |
|
- |
| 15.1 d)2)(Phyaical tests for insulation - Ageing in air Oven : Tensile Variation ) |
- |
2000 |
|
- |
| 15.1 d)2)(Phyaical tests for insulation- Ageing in air oven : Elongation Variation ) |
- |
2000 |
|
- |
| 15.1 d)2)(Physical tests for outer sheath- Ageing in air oven : Tensile stregth ) |
- |
2000 |
|
- |
| 15.1 d)2)(Physical tests for outer sheath -Ageing in air oven : Elongation ) |
- |
2000 |
|
- |
| 15.1 d)2)(Physical tests for outer sheath- Ageing in air oven : Tensile stregth Variation ) |
- |
2000 |
|
- |
| 15.1 d)2)(Physical tests for outer sheath -Ageing in air oven : Elongation Variation ) |
- |
2000 |
|
- |
| 15.1 d)3)(Phyaical tests for insulation : Shrinkage ) |
- |
1000 |
|
- |
| 15.1 d)3)(Phyaical tests for insulation : Shrinkage - Crack observed ) |
- |
1000 |
|
- |
| 15.1 d)3)(Phyaical tests for Sheath : Shrinkage ) |
- |
1000 |
|
- |
| 15.1 d)3)(Phyaical tests for Sheath : Shrinkage - Crack observed ) |
- |
1000 |
|
- |
| 15.1 d)4)(Hot deformation : Insulation ) |
- |
1000 |
|
- |
| 15.1 d)4)(Hot deformation : Sheath ) |
- |
1000 |
|
- |
| 15.1 d)5)( Loss of mass in air oven- Insulation ) |
- |
2000 |
|
- |
| 15.1 d)5)( Loss of mass in air oven- sheath ) |
- |
2000 |
|
- |
| 15.1 d)6)(Heat shock test- Insulation ) |
- |
1000 |
|
- |
| 15.1 d)6)(Heat shock test- sheath ) |
- |
1000 |
|
- |
| 15.1 d)7)(Thermal stability- insulation ) |
- |
1000 |
|
- |
| 15.1 d)7)(Thermal stability- Sheath ) |
- |
1000 |
|
- |
| 15.1 e)(Insulation resistance test : Volume Resistivity ) |
- |
1000 |
|
- |
| 15.1 e)(Insulation resistance test : IR Constant ) |
- |
1000 |
|
- |
| 15.1 f)(High voltage test ( water immersion test )) |
- |
1000 |
|
- |
| 15.1 g)(High voltage test at room temperature) |
- |
1000 |
|
- |
| 15.1 g)(High voltage test at room temperature) |
- |
1000 |
|
- |
| 15.4 a)(Cold bend test- Insulation ( Optional test)) |
- |
1000 |
|
- |
| 15.4 a)(Cold bend test- Sheath ( Optional test)) |
- |
1000 |
|
- |
| 15.4 b)(Cold impact test- Insulation ( Optional test)) |
- |
1000 |
|
- |
| 15.4 b)(Cold impact test- Sheath ( Optional test)) |
- |
1000 |
|
- |
| 15.4 c)(Armour resistance test ( for other than mining cables ).- Optional test ) |
- |
1000 |
|
- |
| 16.1(DETAILS OF TESTS : General) |
- |
500 |
|
- |
| 16.2(DETAILS OF TESTS : High Voltage Test at Room Temperature) |
- |
500 |
|
- |
| 16.3.1(High Voltage Test ( Water Immersion Test ) : a.c. Test) |
- |
1000 |
|
- |
| 16.3.2(High Voltage Test ( Water Immersion Test ) : d.c. Test) |
- |
2000 |
|
- |
| 16.4(Flammability Test) |
- |
1000 |
|
- |
| 16.5(Oxygen Index Test) |
- |
3000 |
|
- |
| 16.6(Flame Retardance Test on Single Cables) |
- |
1000 |
|
- |
| 16.7(Flame Retardance Test on Bunched Cables) |
- |
5000 |
|
- |
| 16.9(Test for Halogen Acid Gas Evolution) |
- |
3000 |
|
- |
| 16.1(Temperature Index) |
- |
3000 |
|
- |
| 17.1(IDENTIFICATION : Manufacturer’s Identification) |
- |
500 |
|
- |
| 17.2(IDENTIFICATION : Cable Identification) |
- |
500 |
|
- |
| 17.2.1(IDENTIFICATION : Cable Identification) |
- |
500 |
|
- |
| 17.3(IDENTIFICATION : Cable Code) |
- |
500 |
|
- |
| 15.1.e(Insulation resistance Test- Insulation resistance At Maximum rated temperature temperature) |
- |
1000 |
|
- |
| 15.1.e(Insulation resistance Test- Insulation resistance constant At Room temperature) |
- |
1000 |
|
- |
| 15.1.e(Insulation resistance Test- Volume Resistivity At Maximum rated temperature temperature) |
- |
1000 |
|
- |
| 15.1.e(Insulation resistance Test- Volume Resistivity At Room temperature) |
- |
1000 |
|
- |
| 16.4(Flammability Test- Un affected portion) |
- |
1000 |
|
- |
| 16.4(Flammability Test- Period of Burning) |
- |
1000 |
|
- |
| 9.3(Minimum Thickness of Reduce core insulation) |
- |
1000 |
|
- |
| 9.2(Thickness of Reduce core insulation) |
- |
1000 |
|
- |
| 3.1 Table 2
IS 8130(Number of wires in the conductor) |
- |
500 |
|
- |
| Cl No. 16.10(Smoke density test) |
- |
3000 |
|
- |
| Cl No. 16.8(Test for specific optical density of smoke) |
- |
5000 |
|
- |
| Table 4(Copper purity test) |
- |
3000 |
|
- |
| Cl.8(Conductor, Number of wires.) |
- |
500 |
|
- |
| Cl.8(Conductor, Number of wires.) |
- |
500 |
|
- |
| Cl.8(Flexibility class) |
- |
500 |
|
- |
| [(Cl.15), (d), 2](After ageing, Elongation of Sheath [Percentage]) |
- |
2000 |
|
- |
|
11 Mar, 2028 |
- - |
| 5974 |
SKC COMPLIANCE LAB PRIVATE LIMITED, MAHADEVPURA
| 6170406
| IS 302 : Part 2 : Sec 15 (2009) |
Safety of household and similar electrical appliances: Part 2 particular requirements: Sec 15 appliances for heating liquids (First Revision) |
- |
23520 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 6.0(Classification) |
- |
0 |
|
- |
| 7(Marking and instructions) |
- |
500 |
|
- |
| 8(Protection against live parts) |
- |
750 |
|
- |
| 9(STARTING OF MOTOR-OPERATED APPLIANCES) |
- |
0 |
|
- |
| 10(POWER INPUT AND CURRENT) |
- |
2500 |
|
- |
| 11(HEATING) |
- |
3000 |
|
- |
| 13(LEAKAGE CURRENT AND ELECTRIC STRENGTH AT OPERATING TEMPERATURE) |
- |
1500 |
|
- |
| 14(TRANSIENT OVERVOLTAGES) |
- |
500 |
|
- |
| 15(MOISTURE RESISTANCE) |
- |
2500 |
|
- |
| 16(LEAKAGE CURRENT AND ELECTRIC STRENGTH) |
- |
1000 |
|
- |
| 17(OVERLOAD PROTECTION OF TRANSFORMERS AND ASSOCIATED CIRCUITS) |
- |
500 |
|
- |
| 18(ENDURANCE) |
- |
0 |
|
- |
| 19(ABNORMAL OPERATION) |
- |
2500 |
|
- |
| 20(STABILITY AND MECHANICAL HAZARDS) |
- |
750 |
|
- |
| 21(MECHANICAL STRENGTH) |
- |
750 |
|
- |
| 22(CONSTRUCTION) |
- |
1000 |
|
- |
| 23(INTERNAL WIRING) |
- |
500 |
|
- |
| 24(COMPONENTS) |
- |
100 |
|
- |
| 25(SUPPLY CONNECTION AND EXTERNAL FLEXIBLE CORDS) |
- |
500 |
|
- |
| 26(TERMINALS FOR EXTERNAL CONDUCTORS) |
- |
500 |
|
- |
| 27(PROVISION FOR EARTHING) |
- |
500 |
|
- |
| 28(SCREWS AND CONNECTIONS) |
- |
500 |
|
- |
| 29(CLEARANCES, CREEPAGE DISTANCES AND SOLID INSULATION) |
- |
350 |
|
- |
| 30(RESISTANCE TO HEAT AND FIRE) |
- |
100 |
|
- |
| 31(RESISTANCE TO RUSTING) |
- |
100 |
|
- |
| 32(RADIATION, TOXICITY AND SIMILAR HAZARDS) |
- |
500 |
|
- |
| 22.106(Interlocks) |
- |
0 |
|
- |
| 22.3(Flexing test) |
- |
0 |
|
- |
| 24(Components) |
- |
0 |
|
- |
| 4(General requirements) |
- |
0 |
|
- |
| 5(General Conditions of tests) |
- |
0 |
|
- |
| 6(Classification- IS 302-1) |
- |
0 |
|
- |
| 6(Classification- IS 302-1) |
- |
0 |
|
- |
| 7.1(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.1(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.1(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.1(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.1(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.1(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.1(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.1(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.1(Marking- IS 302-2-15) |
- |
0 |
|
- |
| 7.3(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.4(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.5(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.6(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.7(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.8(Marking- IS 302-1) |
- |
0 |
|
- |
| 6(Classification- IS 302-1) |
- |
0 |
|
- |
| 6(Classification- IS 302-1) |
- |
0 |
|
- |
| 7.1(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.1(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.1(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.1(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.1(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.1(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.1(Marking- IS 302-1) |
- |
0 |
|
- |
| Marking- IS 302-1(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.1(Marking- IS 302-2-15) |
- |
0 |
|
- |
| 7.3(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.4(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.5(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.6(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.7(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.8(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.9(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.1O(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.11(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.12(Marking- IS 302-2-15) |
- |
0 |
|
- |
| 7.12(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.12.1(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.12.3(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.12.5(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.12.6(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.13(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.14(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.15(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.101(Marking- IS 302-2-15) |
- |
0 |
|
- |
| 8(Protection Against Electric Shock, IS 302-1) |
- |
0 |
|
- |
| 10(Power Input and Current, IS 302-1) |
- |
0 |
|
- |
| 11(Heating, IS 302-1) |
- |
0 |
|
- |
| 11(Heating, IS 302-1) |
- |
0 |
|
- |
| 11(Heating, IS 302-1) |
- |
0 |
|
- |
| 11(Heating, IS 302-1) |
- |
0 |
|
- |
| 13(Electrical Insulation and Leakage Current at Operating Temperature: Leakage current, IS 302-1) |
- |
0 |
|
- |
| 13(Electrical Insulation and Leakage Current at Operating Temperature: High Voltage, IS 302-1) |
- |
0 |
|
- |
| 15.1(Moisture Resistance, IS 302-1) |
- |
0 |
|
- |
| 15.2(Spillage test as 15.2, IS 3.02-1 & 302-2-15) |
- |
0 |
|
- |
| 16(Leakage current as per Cl 16, IS 302-1) |
- |
0 |
|
- |
| 16(electric strength as per Cl 16, IS 302-1) |
- |
0 |
|
- |
| 17(Overload protection of Transformers and Associated Circuits, IS 302-1) |
- |
0 |
|
- |
| 19.13(Abnormal Operation as per Cl 19, IS 302-2-15) |
- |
0 |
|
- |
| 19.13(Abnormal Operation as per Cl 19, IS 302-1) |
- |
0 |
|
- |
| 19.13(Abnormal Operation as per Cl 19, IS 302-1) |
- |
0 |
|
- |
| 19.13(Abnormal Operation as per Cl 19, IS 302-1) |
- |
0 |
|
- |
| 20.1(Stability & Mechanical Hazards, IS 302-1) |
- |
0 |
|
- |
| 21.1(Mechanical Strength, IS 302-1) |
- |
0 |
|
- |
| 21.2(Mechanical Strength, IS 302-1) |
- |
0 |
|
- |
| 22.1(Construction, IS 302-1) |
- |
0 |
|
- |
| 22.7(Construction as per Cl 22.7, IS 3.02-2-15) |
- |
0 |
|
- |
| 22.107(Construction as per Cl 22.7, IS 3.02-2-15) |
- |
0 |
|
- |
| 22.108(Construction as per Cl 22.8, IS 3.02-2-15) |
- |
0 |
|
- |
| 23.1(Internal Wiring, IS 302-1) |
- |
0 |
|
- |
| 23.2(Internal Wiring, IS 302-1) |
- |
0 |
|
- |
| 23.4(Internal Wiring, IS 302-1) |
- |
0 |
|
- |
| 23.5(Internal Wiring, IS 302-1) |
- |
0 |
|
- |
| 23.6(Internal Wiring, IS 302-1) |
- |
0 |
|
- |
| 23.7(Internal Wiring, IS 302-1) |
- |
0 |
|
- |
| 23.8(Internal Wiring, IS 302-1) |
- |
0 |
|
- |
| 23.9(Internal Wiring, IS 302-1) |
- |
0 |
|
- |
| 23.1O(Internal Wiring, IS 302-1) |
- |
0 |
|
- |
| 25.1(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
- |
| 25.2(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
- |
| 25.5(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
- |
| 25.6(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
- |
| 25.8(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
- |
| 25.9(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
- |
| 25.1(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
- |
| 25.11(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
- |
| 25.12(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
- |
| 25.13(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
- |
| 25.14(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
- |
| 25.14(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
- |
| 25.15(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
- |
| 25.16(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
- |
| 25.17(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
- |
| 25.18(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
- |
| 25.19(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
- |
| 25.2(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
- |
| 25.21(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
- |
| 25.22(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
- |
| 26(Terminals for External Conductors, IS 302-1) |
- |
0 |
|
- |
| 27.1(Provision for Earthing, IS 302-1) |
- |
0 |
|
- |
| 27.2(Provision for Earthing, IS 302-1) |
- |
0 |
|
- |
| 27.3(Provision for Earthing, IS 302-1) |
- |
0 |
|
- |
| 27.4(Provision for Earthing, IS 302-1) |
- |
0 |
|
- |
| 27.5(Provision for Earthing, IS 302-1) |
- |
0 |
|
- |
| 28(Screws & Connections, IS 302-1) |
- |
0 |
|
- |
| 29.1(Clearances, Creepage distances and Solid Insulation, IS 302-1) |
- |
0 |
|
- |
| 29.2(Clearances, Creepage distances and Solid Insulation, IS 302-1) |
- |
0 |
|
- |
| 30.1(Resistance to Heat and Fire, IS 302-1) |
- |
0 |
|
- |
| 30.2(Resistance to Heat and Fire, IS 302-1) |
- |
0 |
|
- |
| 31(Resistance of Rusting, IS 302-1) |
- |
0 |
|
- |
| 6.0(Classification) |
- |
0 |
|
- |
| 7(Marking and instructions) |
- |
0 |
|
- |
| 8(Protection against live parts) |
- |
0 |
|
- |
| 9(STARTING OF MOTOR-OPERATED APPLIANCES) |
- |
0 |
|
- |
| 10(POWER INPUT AND CURRENT) |
- |
0 |
|
- |
| 11(HEATING) |
- |
0 |
|
- |
| 13(LEAKAGE CURRENT AND ELECTRIC STRENGTH AT OPERATING TEMPERATURE) |
- |
0 |
|
- |
| 14(TRANSIENT OVERVOLTAGES) |
- |
0 |
|
- |
| 15(MOISTURE RESISTANCE) |
- |
0 |
|
- |
| 16(LEAKAGE CURRENT AND ELECTRIC STRENGTH) |
- |
0 |
|
- |
| 17(OVERLOAD PROTECTION OF TRANSFORMERS AND ASSOCIATED CIRCUITS) |
- |
0 |
|
- |
| 18(ENDURANCE) |
- |
0 |
|
- |
| 19(ABNORMAL OPERATION) |
- |
0 |
|
- |
| 20(STABILITY AND MECHANICAL HAZARDS) |
- |
0 |
|
- |
| 21(MECHANICAL STRENGTH) |
- |
0 |
|
- |
| 22(CONSTRUCTION) |
- |
0 |
|
- |
| 23(INTERNAL WIRING) |
- |
0 |
|
- |
| 24(COMPONENTS) |
- |
0 |
|
- |
| 25(SUPPLY CONNECTION AND EXTERNAL FLEXIBLE CORDS) |
- |
0 |
|
- |
| 26(TERMINALS FOR EXTERNAL CONDUCTORS) |
- |
0 |
|
- |
| 27(PROVISION FOR EARTHING) |
- |
0 |
|
- |
| 28(SCREWS AND CONNECTIONS) |
- |
0 |
|
- |
| 29(CLEARANCES, CREEPAGE DISTANCES AND SOLID INSULATION) |
- |
0 |
|
- |
| 30(RESISTANCE TO HEAT AND FIRE) |
- |
0 |
|
- |
| 31(RESISTANCE TO RUSTING) |
- |
0 |
|
- |
| 32(RADIATION, TOXICITY AND SIMILAR HAZARDS) |
- |
0 |
|
- |
| 22.106(Interlocks) |
- |
0 |
|
- |
| 22.3(Flexing test) |
- |
0 |
|
- |
| 24(Components) |
- |
0 |
|
- |
| 4(General requirements) |
- |
0 |
|
- |
| 5(General Conditions of tests) |
- |
0 |
|
- |
| 6(Classification- IS 302-1) |
- |
0 |
|
- |
| 6(Classification- IS 302-1) |
- |
0 |
|
- |
| 7.1(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.1(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.1(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.1(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.1(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.1(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.1(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.1(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.1(Marking- IS 302-2-15) |
- |
0 |
|
- |
| 7.3(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.4(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.5(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.6(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.7(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.8(Marking- IS 302-1) |
- |
0 |
|
- |
| 6(Classification- IS 302-1) |
- |
0 |
|
- |
| 6(Classification- IS 302-1) |
- |
0 |
|
- |
| 7.1(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.1(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.1(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.1(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.1(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.1(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.1(Marking- IS 302-1) |
- |
0 |
|
- |
| Marking- IS 302-1(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.1(Marking- IS 302-2-15) |
- |
0 |
|
- |
| 7.3(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.4(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.5(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.6(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.7(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.8(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.9(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.1O(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.11(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.12(Marking- IS 302-2-15) |
- |
0 |
|
- |
| 7.12(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.12.1(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.12.3(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.12.5(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.12.6(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.13(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.14(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.15(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.101(Marking- IS 302-2-15) |
- |
0 |
|
- |
| 8(Protection Against Electric Shock, IS 302-1) |
- |
0 |
|
- |
| 10(Power Input and Current, IS 302-1) |
- |
0 |
|
- |
| 11(Heating, IS 302-1) |
- |
0 |
|
- |
| 11(Heating, IS 302-1) |
- |
0 |
|
- |
| 11(Heating, IS 302-1) |
- |
0 |
|
- |
| 11(Heating, IS 302-1) |
- |
0 |
|
- |
| 13(Electrical Insulation and Leakage Current at Operating Temperature: Leakage current, IS 302-1) |
- |
0 |
|
- |
| 13(Electrical Insulation and Leakage Current at Operating Temperature: High Voltage, IS 302-1) |
- |
0 |
|
- |
| 15.1(Moisture Resistance, IS 302-1) |
- |
0 |
|
- |
| 15.2(Spillage test as 15.2, IS 3.02-1 & 302-2-15) |
- |
0 |
|
- |
| 16(Leakage current as per Cl 16, IS 302-1) |
- |
0 |
|
- |
| 16(electric strength as per Cl 16, IS 302-1) |
- |
0 |
|
- |
| 17(Overload protection of Transformers and Associated Circuits, IS 302-1) |
- |
0 |
|
- |
| 19.13(Abnormal Operation as per Cl 19, IS 302-2-15) |
- |
0 |
|
- |
| 19.13(Abnormal Operation as per Cl 19, IS 302-1) |
- |
0 |
|
- |
| 19.13(Abnormal Operation as per Cl 19, IS 302-1) |
- |
0 |
|
- |
| 19.13(Abnormal Operation as per Cl 19, IS 302-1) |
- |
0 |
|
- |
| 20.1(Stability & Mechanical Hazards, IS 302-1) |
- |
0 |
|
- |
| 21.1(Mechanical Strength, IS 302-1) |
- |
0 |
|
- |
| 21.2(Mechanical Strength, IS 302-1) |
- |
0 |
|
- |
| 22.1(Construction, IS 302-1) |
- |
0 |
|
- |
| 22.7(Construction as per Cl 22.7, IS 3.02-2-15) |
- |
0 |
|
- |
| 22.107(Construction as per Cl 22.7, IS 3.02-2-15) |
- |
0 |
|
- |
| 22.108(Construction as per Cl 22.8, IS 3.02-2-15) |
- |
0 |
|
- |
| 23.1(Internal Wiring, IS 302-1) |
- |
0 |
|
- |
| 23.2(Internal Wiring, IS 302-1) |
- |
0 |
|
- |
| 23.4(Internal Wiring, IS 302-1) |
- |
0 |
|
- |
| 23.5(Internal Wiring, IS 302-1) |
- |
0 |
|
- |
| 23.6(Internal Wiring, IS 302-1) |
- |
0 |
|
- |
| 23.7(Internal Wiring, IS 302-1) |
- |
0 |
|
- |
| 23.8(Internal Wiring, IS 302-1) |
- |
0 |
|
- |
| 23.9(Internal Wiring, IS 302-1) |
- |
0 |
|
- |
| 23.1O(Internal Wiring, IS 302-1) |
- |
0 |
|
- |
| 25.1(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
- |
| 25.2(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
- |
| 25.5(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
- |
| 25.6(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
- |
| 25.8(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
- |
| 25.9(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
- |
| 25.1(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
- |
| 25.11(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
- |
| 25.12(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
- |
| 25.13(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
- |
| 25.14(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
- |
| 25.14(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
- |
| 25.15(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
- |
| 25.16(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
- |
| 25.17(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
- |
| 25.18(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
- |
| 25.19(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
- |
| 25.2(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
- |
| 25.21(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
- |
| 25.22(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
- |
| 26(Terminals for External Conductors, IS 302-1) |
- |
0 |
|
- |
| 27.1(Provision for Earthing, IS 302-1) |
- |
0 |
|
- |
| 27.2(Provision for Earthing, IS 302-1) |
- |
0 |
|
- |
| 27.3(Provision for Earthing, IS 302-1) |
- |
0 |
|
- |
| 27.4(Provision for Earthing, IS 302-1) |
- |
0 |
|
- |
| 27.5(Provision for Earthing, IS 302-1) |
- |
0 |
|
- |
| 28(Screws & Connections, IS 302-1) |
- |
0 |
|
- |
| 29.1(Clearances, Creepage distances and Solid Insulation, IS 302-1) |
- |
0 |
|
- |
| 29.2(Clearances, Creepage distances and Solid Insulation, IS 302-1) |
- |
0 |
|
- |
| 30.1(Resistance to Heat and Fire, IS 302-1) |
- |
0 |
|
- |
| 30.2(Resistance to Heat and Fire, IS 302-1) |
- |
0 |
|
- |
| 31(Resistance of Rusting, IS 302-1) |
- |
0 |
|
- |
|
24 May, 2028 |
- Included.w.e.f.26.12.2024
Exclusion
Cl 22.16 (Automatic cord reel)
Cl 22.32 (Oxygen bomb for rubber material)
Cl 22.47 (Water pressure inlet)
Cl Annex BB (Appliance for board ships)
Cl 19.11.4.1 (Electrostatic discharges)
Cl 19.11.4.2 (Radiated fields)
Cl 19.11.4.3 (Fast transient bursts)
Cl 19.11.4.4 (Surge immunity test)
Cl 19.11.4.6 (Class 3 Voltage dips and interruptions)
Cl 19.11.4.5 (Immunity to conducted discharges)
Cl 19.11.4.7 (Harmonics) |
| 5975 |
TUV SUD SOUTH ASIA PRIVATE LIMITED, BENGALURU
| 6180126
| IS 18663 (2024) |
Note Sorting Machines- Specifications |
- |
65000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl 4.2 Safety requirements (Cl 4.1 and subclauses of IS/IEC 62368-1)(General Requirements) |
- |
500 |
|
10% discount to BIS |
| Cl 4.2 Safety requirements (Cl 4.2 and subclauses of IS/IEC 62368-1)(Energy source classifications) |
- |
500 |
|
10% discount to BIS |
| Cl 4.2 Safety requirements (Cl 4.3 and subclauses of IS/IEC 62368-1)(Protection against energy sources) |
- |
500 |
|
10% discount to BIS |
| Cl 4.2 Safety requirements (Cl 4.4 and subclauses of IS/IEC 62368-1)(Safeguards) |
- |
500 |
|
10% discount to BIS |
| Cl 4.2 Safety requirements (Cl 4.5 and subclauses of IS/IEC 62368-1)("Explosion- Requirements
") |
- |
500 |
|
10% discount to BIS |
| Cl 4.2 Safety requirements (Cl 4.6 and subclauses of IS/IEC 62368-1)(Fixing of conductors- Requirements) |
- |
1000 |
|
10% discount to BIS |
| Cl 4.2 Safety requirements (Cl 4.7 and subclauses of IS/IEC 62368-1)(Equipment for direct insertion into mains socket-outlets) |
- |
1000 |
|
10% discount to BIS |
| Cl 4.2 Safety requirements (Cl 4.8 and subclausesof IS/IEC 62368-1)(Equipment containing coin / button cell batteries) |
- |
1000 |
|
10% discount to BIS |
| Cl 4.2 Safety requirements (Cl 4.9 and subclauses of IS/IEC 62368-1)(Likelihood of fire or shock due to entry of conductive objects) |
- |
1000 |
|
10% discount to BIS |
| Cl 4.2 Safety requirements (Cl 4.10 and subclauses of IS/IEC 62368-1)(Components requirements) |
- |
1000 |
|
10% discount to BIS |
| Cl 4.2 Safety requirements (Cl 5.2 and subclauses of IS/IEC 62368-1)(Classification and limits of electrical energy sources) |
- |
1000 |
|
10% discount to BIS |
| Cl 4.2 Safety requirements (Cl 5.3 and subclauses of IS/IEC 62368-1)(Protection against electrical energy sources) |
- |
1000 |
|
10% discount to BIS |
| Cl 4.2 Safety requirements (Cl 5.4 and subclauses of IS/IEC 62368-1)(Insulation materials and requirements) |
- |
1000 |
|
10% discount to BIS |
| Cl 4.2 Safety requirements (Cl 5.5 and subclauses of IS/IEC 62368-1)(Components as safeguards) |
- |
1000 |
|
10% discount to BIS |
| Cl 4.2 Safety requirements (Cl 5.6 and subclauses of IS/IEC 62368-1)(Protective conductor) |
- |
1000 |
|
10% discount to BIS |
| Cl 4.2 Safety requirements (Cl 5.7 and subclauses of IS/IEC 62368-1)(Prospective touch voltage, touch current and protective conductor current.) |
- |
1000 |
|
10% discount to BIS |
| Cl 4.2 Safety requirements (Cl 5.8 and subclauses of IS/IEC 62368-1)(Backfeed safeguard in battery backed up supplies) |
- |
1000 |
|
10% discount to BIS |
| Cl 4.2 Safety requirements (Cl 6.1 of IS/IEC 62368-1)(Electrically-caused fire) |
- |
1000 |
|
10% discount to BIS |
| Cl 4.2 Safety requirements (Cl 6.2 and subclauses of IS/IEC 62368-1)(Classification of power sources (PS) and potential ignition sources (PIS).) |
- |
1000 |
|
10% discount to BIS |
| Cl 4.2 Safety requirements (Cl 6.3 and subclauses of IS/IEC 62368-1)(Safeguards against fire under normal operating conditions and abnormal operating conditions) |
- |
1000 |
|
10% discount to BIS |
| Cl 4.2 Safety requirements (Cl 6.4 and subclauses of IS/IEC 62368-1)(Safeguards against fire under single fault conditions) |
- |
1000 |
|
10% discount to BIS |
| Cl 4.2 Safety requirements (Cl 6.5 and subclauses of IS/IEC 62368-1)(Internal and external wiring) |
- |
1000 |
|
10% discount to BIS |
| Cl 4.2 Safety requirements (Cl 6.6 and subclauses of IS/IEC 62368-1)(Safeguards against fire due to the connection of additional equipment) |
- |
1000 |
|
10% discount to BIS |
| Cl 4.2 Safety requirements (Cl 8, 8.1 to 8.12 and subclauses of IS/IEC 62368-1)(Mechanically-caused injury) |
- |
1000 |
|
10% discount to BIS |
| Cl 4.2 Safety requirements (Cl 9, 9.1 to 9.6 and subclauses of IS/IEC 62368-1)(Thermal burn injury) |
- |
1500 |
|
10% discount to BIS |
| Cl 4.2 Safety requirements (Annex.B, B.1 to B.4 including its subclauses of IS/IEC 62368-1))(Normal operating condition tests, abnormal operating condition tests and single fault condition tests) |
- |
2000 |
|
10% discount to BIS |
| Cl 4.2 Safety requirements (Annex. D, D.1, D.2, D.3 of IS/IEC 62368-1)(Test generators) |
- |
500 |
|
10% discount to BIS |
| Cl 4.2 Safety requirements ( Annex E, E.1, E.2, E.3 of IS/IEC 62368-1)(Test conditions for equipment containing audio amplifiers) |
- |
500 |
|
10% discount to BIS |
| Cl 4.2 Safety requirements ( Annex. F, F.1 to F.5 including its subclauses of IS/IEC 62368-1)(Equipment markings, instructions, and instructional safeguards) |
- |
500 |
|
10% discount to BIS |
| Cl 4.2 Safety requirements ( Annex. G, G.1 to G.16 including its subclauses of IS/IEC 62368-1)(Components) |
- |
1000 |
|
10% discount to BIS |
| Cl 4.2 Safety requirements ( Annex. H, H1 to H3 including its subclauses of IS/IEC 62368-1)(Criteria for telephone ringing signals .) |
- |
500 |
|
10% discount to BIS |
| Cl 4.2 Safety requirements ( Annex I of IS/IEC 62368-1)(Overvoltage categories) |
- |
500 |
|
10% discount to BIS |
| Cl 4.2 Safety requirements ( Annex. J, J.1 to J.3 including its subclauses of IS/IEC 62368-1)(Insulated winding wires for use without interleaved insulation) |
- |
500 |
|
10% discount to BIS |
| Cl 4.2 Safety requirements ( Annex. L .L1 to L.9 including its subclauses of IS/IEC 62368-1)(Disconnect devices) |
- |
500 |
|
10% discount to BIS |
| Cl 4.2 Safety requirements ( Annex. M, M.1 to M.10 including its subclauses of IS/IEC 62368-1)(Equipment containing batteries and their protection circuits) |
- |
500 |
|
10% discount to BIS |
| Cl 4.2 Safety requirements ( Annex.N of IS/IEC 62368-1)(Electrochemical potentials) |
- |
500 |
|
10% discount to BIS |
| Cl 4.2 Safety requirements ( Annex.O of IS/IEC 62368-1)(Measurement of creepage distances and clearances) |
- |
1000 |
|
10% discount to BIS |
| Cl 4.2 Safety requirements ( Annex.P, P.1 to P.4 and its subclauses of IS/IEC 62368-1)(Safeguards against conductive objects) |
- |
500 |
|
10% discount to BIS |
| Cl 4.2 Safety requirements ( Annex.Q, Q.1 to Q.2 and its subclauses of IS/IEC 62368-1)(Circuits intended for interconnection with building wiring) |
- |
1000 |
|
10% discount to BIS |
| Cl 4.2 Safety requirements ( Annex.S S.1 to S.5 and its subclauses of IS/IEC 62368-1)(Tests for resistance to heat and fire) |
- |
1000 |
|
10% discount to BIS |
| Cl 4.2 Safety requirements ( Annex T, T.1 to T.11 and its subclauses of IS/IEC 62368-1)(Mechanical strength tests) |
- |
2000 |
|
10% discount to BIS |
| Cl 4.2 Safety requirements ( Annex V, V.1 to V.2 and its subclauses of IS/IEC 62368-1)(Determination of accessible parts) |
- |
500 |
|
10% discount to BIS |
| Cl 4.2 Safety requirements ( Annex X of IS/IEC 62368-1)(Alternative method for determining clearances for insulation in circuits connected to an AC mains not exceeding 420V peak (300V rms)) |
- |
500 |
|
10% discount to BIS |
| Cl 4.2 Safety requirements ( Annex Y , Y.1 to Y.6 and its subclauses of IS/IEC 62368-1)(Construction requirements for outdoor enclosure) |
- |
500 |
|
10% discount to BIS |
| Cl-4.1, 6.2 Table-1 (i)(Objects not recognized as banknotes) |
- |
500 |
|
10% discount to BIS |
| Cl-4.1, 6.2 Table-1 (ii)(Suspect/counterfeit banknotes) |
- |
500 |
|
10% discount to BIS |
| Cl-4.1, 6.2 Table-1 (iii)(Banknotes that are not clearly authenticated) |
- |
500 |
|
10% discount to BIS |
| Cl-4.1, 6.2 Table-1 (iv) (a)(Banknotes that are identified as genuine and fit;) |
- |
500 |
|
10% discount to BIS |
| Cl-4.1, 6.2 Table-1 (iv) (b)(Banknotes that are identified as genuine and unfit) |
- |
500 |
|
10% discount to BIS |
| Cl-4.1, Table-2 (i)(Piece counting) |
- |
500 |
|
10% discount to BIS |
| Cl-4.1, Table-2 (ii)(Value counting) |
- |
500 |
|
10% discount to BIS |
| Cl-4.1, Table-2 (iii)(Authenticity determination) |
- |
500 |
|
10% discount to BIS |
| Cl-4.1, Table-2 (iv)(Fitness determination) |
- |
500 |
|
10% discount to BIS |
| Cl-4.1, Table-2 (v)(Sorting of banknotes) |
- |
500 |
|
10% discount to BIS |
| Cl-4.3, Table-3 (i)(Serial number recognition) |
- |
500 |
|
10% discount to BIS |
| Cl-4.3, Table-3 (ii)(Data storage and reproduction) |
- |
500 |
|
10% discount to BIS |
| Cl-6.1, Table-4 (i)(Marking and instructions) |
- |
500 |
|
10% discount to BIS |
| Cl-6.1, Table-4 (ii)(Protection against access to live parts) |
- |
2000 |
|
10% discount to BIS |
| Cl-6.1, Table-4 (iii)(Power input and current) |
- |
3000 |
|
10% discount to BIS |
| Cl-6.1, Table-4 (iv)(Heating) |
- |
4000 |
|
10% discount to BIS |
| Cl-6.1, Table-4 (v)(Creepage clearance and solid insulation) |
- |
1000 |
|
10% discount to BIS |
| Cl-6.1, Table-4 (vi)(Humidity conditioning) |
- |
3000 |
|
10% discount to BIS |
| Cl-6.1, Table-4 (vii)(Leakage current and electric strength at operating temperature) |
- |
1500 |
|
10% discount to BIS |
| Cl-6.1, Table-4 (viii)(Provision for earthing) |
- |
1500 |
|
10% discount to BIS |
| 6.2.1(Speed Test) |
- |
500 |
|
10% discount to BIS |
| 6.2.2(Authenticity Test) |
- |
500 |
|
10% discount to BIS |
| 6.2.3(Fitness Test) |
- |
500 |
|
10% discount to BIS |
| 6.2.4(Repeatability Test) |
- |
500 |
|
10% discount to BIS |
| 6.2.5(Stress Test) |
- |
500 |
|
10% discount to BIS |
| 6.2.6(Piece Counting Test) |
- |
500 |
|
10% discount to BIS |
| 6.2.7(Values Counting Test) |
- |
500 |
|
10% discount to BIS |
| Cl 4.2 Safety requirements ( Annex. K, K.1 to K.7 including its subclauses of IS/IEC 62368-1)(Safety Interlocks) |
- |
500 |
|
10% discount to BIS |
|
11 Sep, 2027 |
- Included w.e.f.13.12.2024
exclusion
Cl 4.2 Safety requirements (Cl 4.1 and subclauses of IS/IEC 62368-1) (General Requirements)
Cl 4.2 Safety requirements (Cl 5.4 and subclauses of IS/IEC 62368-1) (Insulation materials and requirements)
Cl 4.2 Safety requirements (Cl 10, 10.1 to 10.6 and subclauses of IS/IEC 62368-1) (Radiation)
Cl 4.2 Safety requirements ( Annex. G, G.1 to G.16 including its subclauses of IS/IEC 62368-1) (Components)
Cl 4.2 Safety requirements ( Annex. G, G.1 to G.16 including its subclauses of IS/IEC 62368-1) (Components)
Cl 4.2 Safety requirements ( Annex. G, G.1 to G.16 including its subclauses of IS/IEC 62368-1) (Components)
Cl 4.2 Safety requirements ( Annex. G, G.1 to G.16 including its subclauses of IS/IEC 62368-1) (Components)
Cl 4.2 Safety requirements ( Annex. J, J.1 to J.3 including its subclauses of IS/IEC 62368-1) (Insulated winding wires for use without interleaved insulation)
Cl 4.2 Safety requirements ( Annex. M, M.1 to M.10 including its subclauses of IS/IEC 62368-1) (Equipment containing batteries and their protection circuits)
Cl 4.2 Safety requirements ( Annex. M, M.1 to M.10 including its subclauses of IS/IEC 62368-1) (Equipment containing batteries and their protection circuits)
Cl 4.2 Safety requirements ( Annex.R, R.1 to R.4 and its subclauses of IS/IEC 62368-1) (Limited short-circuit test)
Cl 4.2 Safety requirements ( Annex Y , Y.1 to Y.6 and its subclauses of IS/IEC 62368-1) (Construction requirements for outdoor enclosure)
Cl 4.2 Safety requirements ( Annex Y , Y.1 to Y.6 and its subclauses of IS/IEC 62368-1) (Construction requirements for outdoor enclosure)
Cl 4.2 Safety requirements ( Annex Y , Y.1 to Y.6 and its subclauses of IS/IEC 62368-1) (Construction requirements for outdoor enclosure)
Cl 4.2 Safety requirements ( Annex Y , Y.1 to Y.6 and its subclauses of IS/IEC 62368-1) (Construction requirements for outdoor enclosure)
Cl 4.2 Safety requirements ( Annex. K, K.1 to K.7 including its subclauses of IS/IEC 62368-1) (Safety Interlocks)
Cl 4.2 Safety requirements ( Annex. K, K.1 to K.7 including its subclauses of IS/IEC 62368-1) (Safety Interlocks) |
| 5976 |
Classic Testing & Research Centre (B17), Noida
| 8180826
| IS 368 (2014) |
Electric immersion water heaters - Specification (Fifth Revision) |
- |
14000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl.6 of IS 302-‐2-‐201:2008(Classification) |
- |
500 |
|
- |
| Cl.7 of IS 302-2-201:2008(Marking and Instruction ) |
- |
500 |
|
- |
| Cl.7 of IS 302-2-201:2008(Marking and Instruction ) |
- |
500 |
|
- |
| Cl.7 of IS 302-2-201:2008(Marking and Instruction ) |
- |
500 |
|
- |
| Cl.7 of IS 302-2-201:2008(Marking and Instruction ) |
- |
500 |
|
- |
| Cl.7 of IS 302-2-201:2008(Marking and Instruction ) |
- |
500 |
|
- |
| Cl.7 of IS 302-2-201:2008(Marking and Instruction ) |
- |
500 |
|
- |
| Cl.7 of IS 302-2-201:2008(Marking and Instruction ) |
- |
500 |
|
- |
| Cl.7 of IS 302-2-201:2008(Marking and Instruction ) |
- |
500 |
|
- |
| Cl.7 of IS 302-2-201:2008(Marking and Instruction ) |
- |
500 |
|
- |
| Cl.7 of IS 302-2-201:2008(Marking and Instruction ) |
- |
500 |
|
- |
| Cl.7 of IS 302-2-201:2008(Marking and Instruction ) |
- |
500 |
|
- |
| Cl.7 of IS 302-2-201:2008(Marking and Instruction ) |
- |
500 |
|
- |
| Cl.7 of IS 302-2-201:2008(Marking and Instruction ) |
- |
500 |
|
- |
| Cl.7 of IS 302-2-201:2008(Marking and Instruction ) |
- |
500 |
|
- |
| Cl.7 of IS 302-2-201:2008(Marking and Instruction ) |
- |
500 |
|
- |
| Cl.7 of IS 302-2-201:2008(Marking and Instruction ) |
- |
500 |
|
- |
| Cl.7 of IS 302-2-201:2008(Marking and Instruction ) |
- |
500 |
|
- |
| Cl.7 of IS 302-2-201:2008(Marking and Instruction ) |
- |
500 |
|
- |
| Cl.7 of IS 302-2-201:2008(Marking and Instruction ) |
- |
500 |
|
- |
| Cl.7 of IS 302-2-201:2008(Marking and Instruction ) |
- |
500 |
|
- |
| Cl.8 of IS 302‐2-201: 2008(Protection Against Access to Live Parts) |
- |
1000 |
|
- |
| Cl.10 of IS 302‐2‐201:2008(Power Input and Current ) |
- |
1000 |
|
- |
| Cl.11 of IS 302-2201: 2008(Heating) |
- |
1000 |
|
- |
| Cl.11 of IS 302-2201: 2008(Heating) |
- |
1000 |
|
- |
| Cl.11 of IS 302-2201: 2008(Heating) |
- |
1000 |
|
- |
| Cl.11 of IS 302-2201: 2008(Heating) |
- |
1000 |
|
- |
| Cl.11 of IS 302-2201: 2008(Heating) |
- |
1000 |
|
- |
| Cl.11 of IS 302-2201: 2008(Heating) |
- |
1000 |
|
- |
| Cl.11 of IS 302-2201: 2008(Heating) |
- |
1000 |
|
- |
| Cl.11 of IS 302-2201: 2008(Heating) |
- |
1000 |
|
- |
| Cl.11 of IS 302-2201: 2008(Heating) |
- |
1000 |
|
- |
| Cl.11 of IS 302-2201: 2008(Heating) |
- |
1000 |
|
- |
| Cl.11 of IS 302-2201: 2008(Heating) |
- |
1000 |
|
- |
| Cl. 12 of IS 368:2014(Operation under overload conditions of appliances with heating elements) |
- |
1000 |
|
- |
| Cl.13 of IS 302-2-201: 2008(Leakage Current & Electric Strength at Operating Temperature) |
- |
1000 |
|
- |
| Cl.13 of IS 302-2-201: 2009(Leakage Current & Electric Strength at Operating Temperature) |
- |
1000 |
|
- |
| Cl.14 of IS 302‐2-201:2008(Transient Over Voltages ) |
- |
1000 |
|
- |
| Cl.15 of IS 302-2-201:2008(Moisture Resistance ) |
- |
1000 |
|
- |
| Cl.15 of IS 302-2-201:2008(Moisture Resistance ) |
- |
1000 |
|
- |
| Cl.16 of IS 302-2-201:2008(Leakage Current & Electric Strength) |
- |
1000 |
|
- |
| Cl.16 of IS 302-2-201:2008(Leakage Current & Electric Strength) |
- |
1000 |
|
- |
| Cl.17 of IS 302‐2-201: 2008(Overload Protection of Transformers & Associated Circuits) |
- |
1000 |
|
- |
| Cl.18 of IS 368:2014(Endurance) |
- |
1000 |
|
- |
| Cl.19 of IS 302‐2-201: 2008(Abnormal Operation ) |
- |
1000 |
|
- |
| Cl.19 of IS 302‐2-201: 2008(Abnormal Operation ) |
- |
1000 |
|
- |
| Cl.19 of IS 302‐2-201: 2008(Abnormal Operation ) |
- |
1000 |
|
- |
| Cl.19 of IS 302‐2-201: 2008(Abnormal Operation ) |
- |
1000 |
|
- |
| Cl.19 of IS 302‐2-201: 2008(Abnormal Operation ) |
- |
1000 |
|
- |
| Cl.20 of IS 302-2-201: 2008(Stability & Mechanical Hazards) |
- |
1000 |
|
- |
| Cl.21 of IS 302-2-201: 2008(Mechanical Strength ) |
- |
1000 |
|
- |
| Cl.21 of IS 302-2-201: 2008(Mechanical Strength ) |
- |
1000 |
|
- |
| Cl.21 of IS 302-2-201: 2008(Mechanical Strength ) |
- |
1000 |
|
- |
| Cl.22 of IS 302-2-201: 2008(Construction) |
- |
1000 |
|
- |
| Cl.22 of IS 302-2-201: 2008(Construction) |
- |
1000 |
|
- |
| Cl.22 of IS 302-2-201: 2008(Construction) |
- |
1000 |
|
- |
| Cl.22 of IS 302-2-201: 2008(Construction) |
- |
1000 |
|
- |
| Cl.23 of 302-2-201:2008(Internal Wiring ) |
- |
1000 |
|
- |
| Cl.23 of 302-2-201:2008(Internal Wiring ) |
- |
1000 |
|
- |
| Cl.23 of 302-2-201:2008(Internal Wiring ) |
- |
1000 |
|
- |
| Cl.23 of 302-2-201:2008(Internal Wiring ) |
- |
1000 |
|
- |
| Cl.23 of 302-2-201:2008(Internal Wiring ) |
- |
1000 |
|
- |
| Cl.23 of 302-2-201:2008(Internal Wiring ) |
- |
1000 |
|
- |
| Cl.23 of 302-2-201:2008(Internal Wiring ) |
- |
1000 |
|
- |
| Cl.23 of 302-2-201:2008(Internal Wiring ) |
- |
1000 |
|
- |
| Cl.23 of 302-2-201:2008(Internal Wiring ) |
- |
1000 |
|
- |
| Cl.24 of IS 302-2-201: 2008(Component) |
- |
1000 |
|
- |
| Cl.24 of IS 302-2-201: 2008(Component) |
- |
1000 |
|
- |
| Cl.24 of IS 302-2-201: 2008(Component) |
- |
1000 |
|
- |
| Cl.24 of IS 302-2-201: 2008(Component) |
- |
1000 |
|
- |
| Cl.24 of IS 302-2-201: 2008(Component) |
- |
1000 |
|
- |
| Cl.24 of IS 302-2-201: 2008(Component) |
- |
1000 |
|
- |
| Cl.24 of IS 302-2-201: 2008(Component) |
- |
1000 |
|
- |
| Cl.24 of IS 302-2-201: 2008(Component) |
- |
1000 |
|
- |
| Cl.24 of IS 302-2-201: 2008(Component) |
- |
1000 |
|
- |
| Cl.25 of IS 302-2-201: 2008(Supply Connection and External Flexible Cords) |
- |
1000 |
|
- |
| Cl.25 of IS 302-2-201: 2008(Supply Connection and External Flexible Cords) |
- |
1000 |
|
- |
| Cl.25 of IS 302-2-201: 2008(Supply Connection and External Flexible Cords) |
- |
1000 |
|
- |
| Cl.25 of IS 302-2-201: 2008(Supply Connection and External Flexible Cords) |
- |
1000 |
|
- |
| Cl.25 of IS 302-2-201: 2008(Supply Connection and External Flexible Cords) |
- |
1000 |
|
- |
| Cl.25 of IS 302-2-201: 2008(Supply Connection and External Flexible Cords) |
- |
1000 |
|
- |
| Cl.25 of IS 302-2-201: 2008(Supply Connection and External Flexible Cords) |
- |
1000 |
|
- |
| Cl.25 of IS 302-2-201: 2008(Supply Connection and External Flexible Cords) |
- |
1000 |
|
- |
| Cl.25 of IS 302-2-201: 2008(Supply Connection and External Flexible Cords) |
- |
1000 |
|
- |
| Cl.25 of IS 302-2-201: 2008(Supply Connection and External Flexible Cords) |
- |
1000 |
|
- |
| Cl.25 of IS 302-2-201: 2008(Supply Connection and External Flexible Cords) |
- |
1000 |
|
- |
| Cl.25 of IS 302-2-201: 2008(Supply Connection and External Flexible Cords) |
- |
1000 |
|
- |
| Cl.25 of IS 302-2-201: 2008(Supply Connection and External Flexible Cords) |
- |
1000 |
|
- |
| Cl.25 of IS 302-2-201: 2008(Supply Connection and External Flexible Cords) |
- |
1000 |
|
- |
| Cl.25 of IS 302-2-201: 2008(Supply Connection and External Flexible Cords) |
- |
1000 |
|
- |
| Cl.25 of IS 302-2-201: 2008(Supply Connection and External Flexible Cords) |
- |
1000 |
|
- |
| Cl.25 of IS 302-2-201: 2008(Supply Connection and External Flexible Cords) |
- |
1000 |
|
- |
| Cl.25 of IS 302-2-201: 2008(Supply Connection and External Flexible Cords) |
- |
1000 |
|
- |
| Cl.25 of IS 302-2-201: 2008(Supply Connection and External Flexible Cords) |
- |
1000 |
|
- |
| Cl.25 of IS 302-2-201: 2008(Supply Connection and External Flexible Cords) |
- |
1000 |
|
- |
| Cl.26 of IS 302-2-201: 2008(Terminals for External Conductors) |
- |
1000 |
|
- |
| Cl.27 of IS 302-2-201: 2008(Provision for Earthing ) |
- |
1000 |
|
- |
| Cl.27 of IS 302-2-201: 2008(Provision for Earthing ) |
- |
1000 |
|
- |
| Cl.27 of IS 302-2-201: 2008(Provision for Earthing ) |
- |
1000 |
|
- |
| Cl.27 of IS 302-2-201: 2008(Provision for Earthing ) |
- |
1000 |
|
- |
| Cl.27 of IS 302-2-201: 2008(Provision for Earthing ) |
- |
1000 |
|
- |
| Cl.27 of IS 302-2-201: 2008(Provision for Earthing ) |
- |
1000 |
|
- |
| Cl.28 of IS 302-2-201: 2008(Screws & Connections ) |
- |
1000 |
|
- |
| Cl.29 of IS 302-2‐201:2008(Clearances, Creepage Distances and Solid Insulation ) |
- |
1000 |
|
- |
| Cl.29 of IS 302-2‐201:2008(Clearances, Creepage Distances and Solid Insulation ) |
- |
1000 |
|
- |
| Cl.30 of IS 302-2‐201:2008(Resistance to Heat and Fire ) |
- |
1000 |
|
- |
| Cl.30 of IS 302-2‐201:2008(Resistance to Heat and Fire ) |
- |
1000 |
|
- |
| Cl.31 of IS 302-2-201:2008(Resistance of Rusting ) |
- |
1000 |
|
- |
| Cl.32 of IS 302-2-201:2008(Radiation, Toxicity and Similar Hazards) |
- |
1000 |
|
- |
| 19.11.4.1(Electrostatic discharges) |
- |
1000 |
|
- |
| 19.11.4.3(Fast transient bursts) |
- |
1000 |
|
- |
| 19.11.4.4(Surge immunity test) |
- |
1000 |
|
- |
| 19.11.4.6(Class 3 Voltage dips and interruptions) |
- |
1000 |
|
- |
| 19.11.4.7(Harmonics) |
- |
1000 |
|
- |
| 4(GENERAL REQUIREMENT) |
- |
1000 |
|
- |
| 5(GENERAL CONDITIONS FOR THE TESTS) |
- |
1000 |
|
- |
|
15 Oct, 2027 |
- Included w.e.f.12.12.2024
Exclusion
19.11.4.2 (Radiated fields)
19.11.4.5 (Immunity to conducted discharges) |
| 5977 |
SKC COMPLIANCE LAB PRIVATE LIMITED, MAHADEVPURA
| 6170406
| IS 302 : Part 2 : Sec 6 (2009) |
Safety of household and similar electrical appliances: Part 2 particular requirements: Sec 6 cooking ranges, hobs, ovens and similar appliances (First Revision) |
- |
22300 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 7.0(Marking and instructions) |
- |
500 |
|
10% discount for BIS |
| 8.0(Protection against access to live part test) |
- |
750 |
|
10% discount for BIS |
| 10.0(Power Input and current test) |
- |
2500 |
|
10% discount for BIS |
| 11.0(Heating test) |
- |
3000 |
|
10% discount for BIS |
| 13.0(Leakage current and electric strength test) |
- |
1500 |
|
10% discount for BIS |
| 14.0(Transient voltages) |
- |
500 |
|
10% discount for BIS |
| 15.0(Moisture Resistance) |
- |
2500 |
|
10% discount for BIS |
| 16.0(Leakage current and electric strength test) |
- |
1000 |
|
10% discount for BIS |
| 17.0(Overload protection of transformers test) |
- |
500 |
|
10% discount for BIS |
| 19.0(Abnormal Operations) |
- |
2500 |
|
10% discount for BIS |
| 20.0(Stability and Mechanical Hazards) |
- |
750 |
|
10% discount for BIS |
| 21.0(Mechanical Strength) |
- |
750 |
|
10% discount for BIS |
| 22.0(Construction verification related tests) |
- |
1000 |
|
10% discount for BIS |
| 23.0(Internal wiring) |
- |
500 |
|
10% discount for BIS |
| 24.0(Components) |
- |
100 |
|
10% discount for BIS |
| 25.0(Supply connections and External Flexible Cords) |
- |
500 |
|
10% discount for BIS |
| 26.0(Terminal for External Conductors) |
- |
500 |
|
10% discount for BIS |
| 27.0(Provision for Earthing) |
- |
500 |
|
10% discount for BIS |
| 28.0(Screws and connections) |
- |
500 |
|
10% discount for BIS |
| 29.0(Clearances and Creepage distances and solid insulation) |
- |
350 |
|
10% discount for BIS |
| 30.0(Resistance to heat and fire) |
- |
100 |
|
10% discount for BIS |
| 31.0(Resistance to rusting) |
- |
1000 |
|
10% discount for BIS |
| 32.0(Radiation, Toxicity and Similar hazards) |
- |
500 |
|
- |
| 19.11.4.1(Electrostatic discharges) |
- |
0 |
|
- |
| 19.11.4.2(Radiated fields) |
- |
0 |
|
- |
| 19.11.4.3(Fast transient bursts) |
- |
0 |
|
- |
| 19.11.4.4(Surge immunity test) |
- |
0 |
|
- |
| 6.0(Classification) |
- |
0 |
|
- |
| 19.11.4.5(Immunity to conducted discharges) |
- |
0 |
|
- |
| 19.11.4.6(Class 3 Voltage dips and interruptions) |
- |
0 |
|
- |
| 19.11.4.7(Harmonics) |
- |
0 |
|
- |
| 9.0(Starting of motor-operated appliances test) |
- |
0 |
|
- |
| 18.0(Endurance test) |
- |
0 |
|
- |
| 4(General Requirements) |
- |
0 |
|
- |
| 5(General condition for the tests) |
- |
0 |
|
- |
| 7.0(Marking and instructions) |
- |
2000 |
|
- |
| 8.0(Protection against access to live part test) |
- |
2000 |
|
- |
| 10.0(Power Input and current test) |
- |
3000 |
|
- |
| 11.0(Heating test) |
- |
5000 |
|
- |
| 13.0(Leakage current and electric strength test) |
- |
3000 |
|
- |
| 14.0(Transient voltages) |
- |
1000 |
|
- |
| 15.0(Moisture Resistance) |
- |
5000 |
|
- |
| 16.0(Leakage current and electric strength test) |
- |
3000 |
|
- |
| 17.0(Overload protection of transformers test) |
- |
2000 |
|
- |
| 19.0(Abnormal Operations) |
- |
8000 |
|
- |
| 20.0(Stability and Mechanical Hazards) |
- |
3000 |
|
- |
| 21.0(Mechanical Strength) |
- |
2000 |
|
- |
| 22.0(Construction verification related tests) |
- |
2000 |
|
- |
| 23.0(Internal wiring) |
- |
2000 |
|
- |
| 24.0(Components) |
- |
3000 |
|
- |
| 25.0(Supply connections and External Flexible Cords) |
- |
1500 |
|
- |
| 26.0(Terminal for External Conductors) |
- |
1500 |
|
- |
| 27.0(Provision for Earthing) |
- |
2000 |
|
- |
| 28.0(Screws and connections) |
- |
2000 |
|
- |
| 29.0(Clearances and Creepage distances and solid insulation) |
- |
1500 |
|
- |
| 30.0(Resistance to heat and fire) |
- |
2000 |
|
- |
| 31.0(Resistance to rusting) |
- |
2000 |
|
- |
| 32.0(Radiation, Toxicity and Similar hazards) |
- |
1500 |
|
- |
| 19.11.4.1(Electrostatic discharges) |
- |
0 |
|
- |
| 19.11.4.2(Radiated fields) |
- |
0 |
|
- |
| 19.11.4.3(Fast transient bursts) |
- |
0 |
|
- |
| 19.11.4.4(Surge immunity test) |
- |
0 |
|
- |
| 6.0(Classification) |
- |
0 |
|
- |
| 19.11.4.5(Immunity to conducted discharges) |
- |
0 |
|
- |
| 19.11.4.6(Class 3 Voltage dips and interruptions) |
- |
0 |
|
- |
| 19.11.4.7(Harmonics) |
- |
0 |
|
- |
| 9.0(Starting of motor-operated appliances test) |
- |
0 |
|
- |
| 18.0(Endurance test) |
- |
0 |
|
- |
| 4(General Requirements) |
- |
0 |
|
- |
| 5(General condition for the tests) |
- |
0 |
|
- |
| 7.0(Marking and instructions) |
- |
0 |
|
- |
| 8.0(Protection against access to live part test) |
- |
0 |
|
- |
| 10.0(Power Input and current test) |
- |
0 |
|
- |
| 11.0(Heating test) |
- |
0 |
|
- |
| 13.0(Leakage current and electric strength test) |
- |
0 |
|
- |
| 14.0(Transient voltages) |
- |
0 |
|
- |
| 15.0(Moisture Resistance) |
- |
0 |
|
- |
| 16.0(Leakage current and electric strength test) |
- |
0 |
|
- |
| 17.0(Overload protection of transformers test) |
- |
0 |
|
- |
| 19.0(Abnormal Operations) |
- |
0 |
|
- |
| 20.0(Stability and Mechanical Hazards) |
- |
0 |
|
- |
| 21.0(Mechanical Strength) |
- |
0 |
|
- |
| 22.0(Construction verification related tests) |
- |
0 |
|
- |
| 23.0(Internal wiring) |
- |
0 |
|
- |
| 24.0(Components) |
- |
0 |
|
- |
| 25.0(Supply connections and External Flexible Cords) |
- |
0 |
|
- |
| 26.0(Terminal for External Conductors) |
- |
0 |
|
- |
| 27.0(Provision for Earthing) |
- |
0 |
|
- |
| 28.0(Screws and connections) |
- |
0 |
|
- |
| 29.0(Clearances and Creepage distances and solid insulation) |
- |
0 |
|
- |
| 30.0(Resistance to heat and fire) |
- |
0 |
|
- |
| 31.0(Resistance to rusting) |
- |
0 |
|
- |
| 32.0(Radiation, Toxicity and Similar hazards) |
- |
0 |
|
- |
| 6.0(Classification) |
- |
0 |
|
- |
| 9.0(Starting of motor-operated appliances test) |
- |
0 |
|
- |
| 18.0(Endurance test) |
- |
0 |
|
- |
| 4(General Requirements) |
- |
0 |
|
- |
| 5(General condition for the tests) |
- |
0 |
|
- |
| 7.0(Marking and instructions) |
- |
0 |
|
- |
| 8.0(Protection against access to live part test) |
- |
0 |
|
- |
| 10.0(Power Input and current test) |
- |
0 |
|
- |
| 11.0(Heating test) |
- |
0 |
|
- |
| 13.0(Leakage current and electric strength test) |
- |
0 |
|
- |
| 14.0(Transient voltages) |
- |
0 |
|
- |
| 15.0(Moisture Resistance) |
- |
0 |
|
- |
| 16.0(Leakage current and electric strength test) |
- |
0 |
|
- |
| 17.0(Overload protection of transformers test) |
- |
0 |
|
- |
| 19.0(Abnormal Operations) |
- |
0 |
|
- |
| 20.0(Stability and Mechanical Hazards) |
- |
0 |
|
- |
| 21.0(Mechanical Strength) |
- |
0 |
|
- |
| 22.0(Construction verification related tests) |
- |
0 |
|
- |
| 23.0(Internal wiring) |
- |
0 |
|
- |
| 24.0(Components) |
- |
0 |
|
- |
| 25.0(Supply connections and External Flexible Cords) |
- |
0 |
|
- |
| 26.0(Terminal for External Conductors) |
- |
0 |
|
- |
| 27.0(Provision for Earthing) |
- |
0 |
|
- |
| 28.0(Screws and connections) |
- |
0 |
|
- |
| 29.0(Clearances and Creepage distances and solid insulation) |
- |
0 |
|
- |
| 30.0(Resistance to heat and fire) |
- |
0 |
|
- |
| 31.0(Resistance to rusting) |
- |
0 |
|
- |
| 32.0(Radiation, Toxicity and Similar hazards) |
- |
0 |
|
- |
| 6.0(Classification) |
- |
0 |
|
- |
| 9.0(Starting of motor-operated appliances test) |
- |
0 |
|
- |
| 18.0(Endurance test) |
- |
0 |
|
- |
| 4(General Requirements) |
- |
0 |
|
- |
| 5(General condition for the tests) |
- |
0 |
|
- |
| 7.0(Marking and instructions) |
- |
- |
|
- |
| 8.0(Protection against access to live part test) |
- |
- |
|
- |
| 10.0(Power Input and current test) |
- |
- |
|
- |
| 11.0(Heating test) |
- |
- |
|
- |
| 13.0(Leakage current and electric strength test) |
- |
- |
|
- |
| 14.0(Transient voltages) |
- |
- |
|
- |
| 15.0(Moisture Resistance) |
- |
- |
|
- |
| 16.0(Leakage current and electric strength test) |
- |
- |
|
- |
| 17.0(Overload protection of transformers test) |
- |
- |
|
- |
| 19.0(Abnormal Operations) |
- |
- |
|
- |
| 20.0(Stability and Mechanical Hazards) |
- |
- |
|
- |
| 21.0(Mechanical Strength) |
- |
- |
|
- |
| 22.0(Construction verification related tests) |
- |
- |
|
- |
| 23.0(Internal wiring) |
- |
- |
|
- |
| 24.0(Components) |
- |
- |
|
- |
| 25.0(Supply connections and External Flexible Cords) |
- |
- |
|
- |
| 26.0(Terminal for External Conductors) |
- |
- |
|
- |
| 27.0(Provision for Earthing) |
- |
- |
|
- |
| 28.0(Screws and connections) |
- |
- |
|
- |
| 29.0(Clearances and Creepage distances and solid insulation) |
- |
- |
|
- |
| 30.0(Resistance to heat and fire) |
- |
- |
|
- |
| 31.0(Resistance to rusting) |
- |
- |
|
- |
| 32.0(Radiation, Toxicity and Similar hazards) |
- |
- |
|
- |
| 6.0(Classification) |
- |
- |
|
- |
| 9.0(Starting of motor-operated appliances test) |
- |
- |
|
- |
| 18.0(Endurance test) |
- |
- |
|
- |
| 4(General Requirements) |
- |
- |
|
- |
| 5(General condition for the tests) |
- |
- |
|
- |
|
24 May, 2028 |
- Included.w.e.f.26.12.2024
Exclusion
Cl 19.11.4.1 (Electrostatic discharges)
Cl 19.11.4.2 (Radiated fields)
Cl 19.11.4.3 (Fast transient bursts)
Cl 19.11.4.4 (Surge immunity test)
Cl 19.11.4.5 (Immunity to conducted discharges)
Cl 19.11.4.6 (Class 3 Voltage dips and interruptions)
Cl 19.11.4.7 (Harmonics) |
| 5978 |
LUCID LABORATORIES PRIVATE LIMITED, HYDERABAD
| 6121636
| IS 14650 (2023) |
UNALLOYED AND ALLOYED STEEL INGOT AND SEMI-FINISHED PRODUCTS FOR RE-ROLLING PURPOSES - SPECIFICATION (First Revision) |
- |
8400 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Clause - 7.1(CARBON) |
- |
200 |
|
- |
| Clause - 7.1(SULPHUR) |
- |
200 |
|
- |
| Clause - 7.1(PHOSPHURS) |
- |
200 |
|
- |
| Clause - 7.1(MANGANESE) |
- |
200 |
|
- |
| Clause - 7.1(NITROGEN) |
- |
400 |
|
- |
| As per Clause 10(Dimension) |
- |
0 |
|
- |
| As per Clause 10.1(Dimension Width) |
- |
60 |
|
- |
| As per Clause 10.1(Dimension Thickness) |
- |
60 |
|
- |
| As per Clause 10.2(Dimension Length) |
- |
60 |
|
- |
| As per Clause 11.5(Bend) |
- |
100 |
|
- |
| As per Clause 11.6(Camber) |
- |
100 |
|
- |
| As per Clause 11.7 (i)(Out of Square) |
- |
60 |
|
- |
| As per Clause 11.7 (ii)(Round Corners) |
- |
60 |
|
- |
| As per Clause 12/12.1/12.2/12.3(Freedom from defects) |
- |
100 |
|
- |
| Clause. 13(Macro examination test.) |
- |
1500 |
|
- |
| Clause. 13(Sulphur print.) |
- |
1500 |
|
- |
| Clause. 13(Inclusion content) |
- |
1000 |
|
- |
| Clause.7.1(Silicon) |
- |
200 |
|
- |
| Clause.7.1(Carbon Equbalant) |
- |
1000 |
|
- |
| Clause.7.1(Microalloy element) |
- |
800 |
|
- |
| As per Clause 11/11.1/11.2/11.3/11.4(Tolerances) |
- |
50 |
|
- |
| As per Clause 11.7 (iii)(Ridges due to gas cutting) |
- |
50 |
|
- |
| As per Clause 11.7 (iv)(Taper (Width variation on top and bottom surface at one location) |
- |
50 |
|
- |
| As per Clause 11.7 (v)(Edge slanting (Width variation on top and bottom surface at one location) |
- |
50 |
|
- |
| As per Clause 11.7 (vi)(Convexity(Difference in thickness from edge to curve) |
- |
50 |
|
- |
| As per Clause 11.7 (vii)(Chamfering (Length variation on top and bottom surface at one location) |
- |
50 |
|
- |
| As per Clause 11.7 (viii)(Wedge (Thickness variation at the edges along the cross section) |
- |
50 |
|
- |
| As per Clause 11.7 (ix)(Scarfing pits) |
- |
50 |
|
- |
| Clause. 13(Macro examination test.) |
- |
50 |
|
- |
| Clause. 14(Marking) |
- |
50 |
|
- |
| Clause.15(Ordering information) |
- |
50 |
|
- |
| Clause.6.0(Manufacture) |
- |
50 |
|
- |
|
19 Apr, 2028 |
- - |
| 5979 |
Classic Testing & Research Centre (B17), Noida
| 8180826
| IS 4250 (1980) |
Specification for domestic electric food - Mixers (Liquidizers And Grinders) (First Revision) |
- |
20000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 6(Classification- IS 302-1 ) |
- |
500 |
|
- |
| 6(Classification- IS 302-1) |
- |
500 |
|
- |
| 7.1(Marking- IS 302-1) |
- |
500 |
|
- |
| 7.1(Marking- IS 302-1) |
- |
500 |
|
- |
| 7.1(Marking- IS 302-1) |
- |
500 |
|
- |
| 7.1(Marking- IS 302-1) |
- |
500 |
|
- |
| 7.1(Marking- IS 302-1) |
- |
500 |
|
- |
| 7.1(Marking- IS 302-1) |
- |
500 |
|
- |
| 7.1(Marking- IS 302-1) |
- |
500 |
|
- |
| 7.1(Marking- IS 302-1) |
- |
500 |
|
- |
| 7.1(Marking- IS 302-1) |
- |
500 |
|
- |
| 7.1(Marking- IS 302-1) |
- |
500 |
|
- |
| 7.1(Marking- IS 302-1) |
- |
500 |
|
- |
| 7.1(Marking- IS 302-1) |
- |
500 |
|
- |
| 7.1(Marking- IS 302-1) |
- |
500 |
|
- |
| 7.2(Marking) |
- |
500 |
|
- |
| 7.1(Marking- IS 302-1) |
- |
500 |
|
- |
| 7.1(Marking- IS 302-1) |
- |
500 |
|
- |
| 7.1(Marking- IS 302-1) |
- |
500 |
|
- |
| 7.4(Marking) |
- |
500 |
|
- |
| 7.5(Marking) |
- |
500 |
|
- |
| 7.6(Marking) |
- |
500 |
|
- |
| 8( Protection Against Electric Shock, IS 302-1) |
- |
1000 |
|
- |
| 9(Starting, IS 302-1) |
- |
0 |
|
- |
| 10(Power Input and Current, IS 302-1) |
- |
1000 |
|
- |
| 11(Heating, IS 302-1) |
- |
1000 |
|
- |
| 11(Heating, IS 302-1) |
- |
1000 |
|
- |
| 11(Heating, IS 302-1) |
- |
1000 |
|
- |
| 11(Heating, IS 302-1) |
- |
1000 |
|
- |
| 11(Heating, IS 302-1) |
- |
1000 |
|
- |
| 13(Electrical Insulation and Leakage Current at Operating Temperature: Leakage current, IS 302-1) |
- |
1000 |
|
- |
| 13(Electrical Insulation and Leakage Current at Operating Temperature: High Voltage, IS 302-1) |
- |
1000 |
|
- |
| 14(Transient Over Voltages, IS 302-1) |
- |
1000 |
|
- |
| 15.1(Moisture Resistance, IS 302-1) |
- |
1000 |
|
- |
| 15.2(Moisture Resistance-Spillage test) |
- |
1000 |
|
- |
| 15(Moisture Resistance, IS 302-1) |
- |
1000 |
|
- |
| 16(Electrical Insulation and Leakage Current at Operating Temperature: Leakage current, IS 302-1) |
- |
1000 |
|
- |
| 16(Electrical Insulation and Leakage Current at Operating Temperature: High Voltage, IS 302-1) |
- |
1000 |
|
- |
| 19(Abnormal Operation, IS 302-1) |
- |
1000 |
|
- |
| 19(Abnormal Operation, IS 302-1) |
- |
1000 |
|
- |
| 19(Abnormal Operation, IS 302-1) |
- |
1000 |
|
- |
| 19(Abnormal Operation, IS 302-1) |
- |
1000 |
|
- |
| 20(Stability & Mechanical Hazards, IS 302-1) |
- |
1000 |
|
- |
| 20(Stability & Mechanical Hazards, IS 302-1) |
- |
1000 |
|
- |
| 21(Mechanical Strength, IS 302-1) |
- |
1000 |
|
- |
| 21(Mechanical Strength, IS 302-1) |
- |
1000 |
|
- |
| 22.1(Construction, IS 302-1) |
- |
1000 |
|
- |
| 22.2(Construction) |
- |
1000 |
|
- |
| 22.3(Construction) |
- |
1000 |
|
- |
| 22.4(Construction) |
- |
1000 |
|
- |
| 22.5(Construction) |
- |
1000 |
|
- |
| 22.6(Construction) |
- |
1000 |
|
- |
| 22.8(Construction) |
- |
1000 |
|
- |
| 22.9(Construction) |
- |
1000 |
|
- |
| 22.1(Construction) |
- |
1000 |
|
- |
| 23(Internal Wiring, IS 302-1) |
- |
1000 |
|
- |
| 23(Internal Wiring, IS 302-1) |
- |
1000 |
|
- |
| 23(Internal Wiring, IS 302-1) |
- |
1000 |
|
- |
| 23(Internal Wiring, IS 302-1) |
- |
1000 |
|
- |
| 23(Internal Wiring, IS 302-1) |
- |
1000 |
|
- |
| 23(Internal Wiring, IS 302-1) |
- |
1000 |
|
- |
| 23(Internal Wiring, IS 302-1) |
- |
1000 |
|
- |
| 23(Internal Wiring, IS 302-1) |
- |
1000 |
|
- |
| 23(Internal Wiring, IS 302-1) |
- |
1000 |
|
- |
| 23(Internal Wiring, IS 302-1) |
- |
1000 |
|
- |
| 24.1(Components, IS 302-1) |
- |
1000 |
|
- |
| 24.1(Components, IS 302-1) |
- |
1000 |
|
- |
| 24.1(Components, IS 302-1) |
- |
1000 |
|
- |
| 24.1(Components, IS 302-1) |
- |
1000 |
|
- |
| 24.2(Components) |
- |
1000 |
|
- |
| 24.4(Components) |
- |
1000 |
|
- |
| 24.5(Components) |
- |
1000 |
|
- |
| 24.6(Components) |
- |
1000 |
|
- |
| 24.7(Components) |
- |
1000 |
|
- |
| 24.8(Components) |
- |
1000 |
|
- |
| 24.9(Components) |
- |
1000 |
|
- |
| 25(Supply Connection and External Flexible Cords, IS 302-1) |
- |
1000 |
|
- |
| 25(Supply Connection and External Flexible Cords, IS 302-1) |
- |
1000 |
|
- |
| 25(Supply Connection and External Flexible Cords, IS 302-1) |
- |
1000 |
|
- |
| 25(Supply Connection and External Flexible Cords, IS 302-1) |
- |
1000 |
|
- |
| 25(Supply Connection and External Flexible Cords, IS 302-1) |
- |
1000 |
|
- |
| 25(Supply Connection and External Flexible Cords, IS 302-1) |
- |
1000 |
|
- |
| 25(Supply Connection and External Flexible Cords, IS 302-1) |
- |
1000 |
|
- |
| 25(Supply Connection and External Flexible Cords, IS 302-1) |
- |
1000 |
|
- |
| 25(Supply Connection and External Flexible Cords, IS 302-1) |
- |
1000 |
|
- |
| 25(Supply Connection and External Flexible Cords, IS 302-1) |
- |
1000 |
|
- |
| 25(Supply Connection and External Flexible Cords, IS 302-1) |
- |
1000 |
|
- |
| 25(Supply Connection and External Flexible Cords, IS 302-1) |
- |
1000 |
|
- |
| 25(Supply Connection and External Flexible Cords, IS 302-1) |
- |
1000 |
|
- |
| 25(Supply Connection and External Flexible Cords, IS 302-1) |
- |
1000 |
|
- |
| 25(Supply Connection and External Flexible Cords, IS 302-1) |
- |
1000 |
|
- |
| 25(Supply Connection and External Flexible Cords, IS 302-1) |
- |
1000 |
|
- |
| 25(Supply Connection and External Flexible Cords, IS 302-1) |
- |
1000 |
|
- |
| 26(Terminals for External Conductors, IS 302-1) |
- |
1000 |
|
- |
| 27(Provision for Earthing, IS 302-1) |
- |
1000 |
|
- |
| 27(Provision for Earthing, IS 302-1) |
- |
1000 |
|
- |
| 27(Provision for Earthing, IS 302-1) |
- |
1000 |
|
- |
| 27(Provision for Earthing, IS 302-1) |
- |
1000 |
|
- |
| 27(Provision for Earthing, IS 302-1) |
- |
1000 |
|
- |
| 28(Screws & Connections, IS 302-1) |
- |
1000 |
|
- |
| 29(Clearances and Distances through Insulation, IS 302-1) |
- |
1000 |
|
- |
| 29(Clearances and Distances through Insulation, IS 302-1) |
- |
1000 |
|
- |
| 30(Resistance to Heat, Fire, Tracking, IS 302-1) |
- |
1000 |
|
- |
| 30(Resistance to Heat, Fire, Tracking, IS 302-1) |
- |
1000 |
|
- |
| 31(Resistance of Rusting, IS 302-1) |
- |
1000 |
|
- |
| 34.2(Operational tests- Grinding coffee (for machines which have a dry grinding arrangement)) |
- |
1000 |
|
- |
| 34.2(Operational tests- Grinding coffee (for machines which have a dry grinding arrangement)) |
- |
1000 |
|
- |
| 34.2(Operational tests- Grinding coffee (for machines which have a dry grinding arrangement)) |
- |
1000 |
|
- |
| 34.3(Whisking egg whites ) |
- |
1000 |
|
- |
| 34.4(IDLI batter-Grinding of black gram) |
- |
1000 |
|
- |
| 34.4(IDLI batter-Grinding of rice) |
- |
1000 |
|
- |
| 34.4(IDLI batter-Grinding of rice) |
- |
1000 |
|
- |
| 34.4(IDLI batter-Grinding of rice) |
- |
1000 |
|
- |
| 34.5.1 (a)(Operational test for juicers ) |
- |
1000 |
|
- |
| 34.5.1 (b)(Operational test for juicers ) |
- |
1000 |
|
- |
| 34.5.2(Operational test for juicers ) |
- |
1000 |
|
- |
| 35(Temperature withstand test for bowl) |
- |
1000 |
|
- |
| 36(Test for controls ) |
- |
1000 |
|
- |
| 37(Strength of Assembly ) |
- |
1000 |
|
- |
| 37(Strength of Assembly ) |
- |
1000 |
|
- |
| Cl 37(Strength of assembly) |
- |
1000 |
|
- |
| Cl 36(Test for controls) |
- |
1000 |
|
- |
| Cl 35(Temperature withstand test for bowl) |
- |
1000 |
|
- |
| Cl 34(Operational Tests) |
- |
1000 |
|
- |
| Cl.32(Radiation, toxicity and similar hazards) |
- |
1000 |
|
- |
| Cl.31(Resistance to rusting) |
- |
1000 |
|
- |
| Cl.30(Resistance to heat and fire) |
- |
1000 |
|
- |
| CL.29(Clearances, Creepage distances and Solid Insulation) |
- |
1000 |
|
- |
| Cl.28(Screws and connections) |
- |
1000 |
|
- |
| Cl.27(Provision for Earthing) |
- |
1000 |
|
- |
| Cl.26(Terminals for external conductors) |
- |
1000 |
|
- |
| Cl.25(Supply connection and external flexible cords) |
- |
1000 |
|
- |
| Cl.24(Components) |
- |
1000 |
|
- |
| Cl.23(Internal wiring) |
- |
1000 |
|
- |
| Cl.22(Construction) |
- |
1000 |
|
- |
| Cl.21(Mechanical Strength) |
- |
1000 |
|
- |
| Cl.20(Stability & Mechanical Hazards) |
- |
1000 |
|
- |
| Cl.19(Abnormal operation) |
- |
1000 |
|
- |
| Cl.18(Endurance) |
- |
1000 |
|
- |
| Cl. 16(Leakage current and Electric strength) |
- |
1000 |
|
- |
| Cl.15(Moisture Resistance) |
- |
1000 |
|
- |
| Cl.14(Transient Over voltage) |
- |
1000 |
|
- |
| Cl.13(Leakage current and Electric strength at operating temperature) |
- |
1000 |
|
- |
| Cl.11(Temperature rise/ Heating) |
- |
1000 |
|
- |
| Cl.10(Power Input and Current) |
- |
1000 |
|
- |
| Cl.8(Protection against access to live parts/ Protection against electric shock) |
- |
1000 |
|
- |
| Cl. 7(Marking and instructions) |
- |
500 |
|
- |
| Cl. 6(Classification) |
- |
500 |
|
- |
| 3(GENERAL REQUIREMENTS) |
- |
500 |
|
- |
| 4(GENERAL NOTES ON TESTS) |
- |
500 |
|
- |
| 5(RATING) |
- |
500 |
|
- |
| 19.11.4.1(Electrostatic discharges) |
- |
1000 |
|
- |
| 19.11.4.3(Fast transient bursts) |
- |
1000 |
|
- |
| 19.11.4.4(Surge immunity test) |
- |
1000 |
|
- |
| 19.11.4.6(Class 3 Voltage dips and interruptions) |
- |
1000 |
|
- |
| 19.11.4.7(Harmonics) |
- |
1000 |
|
- |
|
15 Oct, 2027 |
- Included w.e.f.12.12.2024
Exclusion
Cl 19.11.4.2 (Radiated fields)
CL 19.11.4.5 (Immunity to conducted discharges) |
| 5980 |
DELHI TEST HOUSE, Azadhpur
| 8131406
| IS 9532 (2023) |
CHAKKA AND SHRIKHAND - SPECIFICATION (First Revision of IS 9532) |
- |
8040 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 6.1.2(Appearance and colours- IS 9532-2023) |
- |
500 |
|
COMPLETE TESTING-12500/- |
| 6.1.3(Odour and Flavour- IS 9532-2023) |
- |
500 |
|
COMPLETE TESTING-12500/- |
| 6.1.4(Texture and Consistency- IS 9532-2023) |
- |
500 |
|
COMPLETE TESTING-12500/- |
| Table 1 clause 6.1.6 (i)(Total solids-IS 11622) |
- |
1000 |
|
COMPLETE TESTING-12500/- |
| Table 1 clause 6.1.6 (iii)(Milk protein (on dry basis)- IS 11917) |
- |
1000 |
|
COMPLETE TESTING-12500/- |
| Table 1 clause 6.1.6 (iv)(Titrable acidity (as lactic acid)- 12 Of IS 1479 Part 1) |
- |
1000 |
|
COMPLETE TESTING-12500/- |
| Table 1 clause 6.1.6 (v)(Total ash (on dry basis) -Annex C of IS 14433) |
- |
500 |
|
COMPLETE TESTING-12500/- |
| Table 2 clause 6.1.6 & 6.2.6 (vi)(Listeria monocytogenes
/g) |
- |
1000 |
|
COMPLETE TESTING-12500/- |
| Table 2 clause 6.1.6 & 6.2.6 (v)(Salmonella sp.) |
- |
1000 |
|
COMPLETE TESTING-12500/- |
| Table 2 clause 6.1.6 & 6.2.6 (ii)(Staphylococcus aureus(Coagulase positive)) |
- |
1000 |
|
COMPLETE TESTING-12500/- |
| Table 2 clause 6.1.6 & 6.2.6 (i)(Coliform count) |
- |
1000 |
|
COMPLETE TESTING-12500/- |
| Table 2 clause 6.1.6 & 6.2.6 (iii)(Yeast & Mould count) |
- |
1000 |
|
COMPLETE TESTING-12500/- |
| Table 2 clause 6.1.6 & 6.2.6 (iv)(E.coli) |
- |
1000 |
|
COMPLETE TESTING-12500/- |
| Table 1 clause 6.1.6 (ii)(Milk fat (on drybasis)- IS 11762) |
- |
500 |
|
COMPLETE TESTING-12500/- |
| 6.1.2(Appearance and colours- IS 9532-2023) |
- |
250 |
|
COMPLETE TESTING-12500/- |
| 6.1.3(Odour and Flavour- IS 9532-2023) |
- |
250 |
|
COMPLETE TESTING-12500/- |
| 6.1.4(Texture and Consistency- IS 9532-2023) |
- |
250 |
|
COMPLETE TESTING-12500/- |
| Table 1 clause 6.1.6 (i)(Total solids-IS 11622) |
- |
1000 |
|
COMPLETE TESTING-12500/- |
| Table 1 clause 6.1.6 (iii)(Milk protein (on dry basis)- IS 11917) |
- |
1000 |
|
COMPLETE TESTING-12500/- |
| Table 1 clause 6.1.6 (iv)(Titrable acidity (as lactic acid)- 12 Of IS 1479 Part 1) |
- |
1000 |
|
COMPLETE TESTING-12500/- |
| Table 1 clause 6.1.6 (v)(Total ash (on dry basis) -Annex C of IS 14433) |
- |
500 |
|
COMPLETE TESTING-12500/- |
| Table 2 clause 6.1.6 & 6.2.6 (vi)(Listeria monocytogenes
/g) |
- |
1000 |
|
COMPLETE TESTING-12500/- |
| Table 2 clause 6.1.6 & 6.2.6 (v)(Salmonella sp.) |
- |
1000 |
|
COMPLETE TESTING-12500/- |
| Table 2 clause 6.1.6 & 6.2.6 (ii)(Staphylococcus aureus(Coagulase positive)) |
- |
1000 |
|
COMPLETE TESTING-12500/- |
| Table 2 clause 6.1.6 & 6.2.6 (i)(Coliform count) |
- |
1000 |
|
COMPLETE TESTING-12500/- |
| Table 2 clause 6.1.6 & 6.2.6 (iii)(Yeast & Mould count) |
- |
1000 |
|
COMPLETE TESTING-12500/- |
| Table 2 clause 6.1.6 & 6.2.6 (iv)(E.coli) |
- |
1000 |
|
COMPLETE TESTING-12500/- |
| Table 1 clause 6.1.6 (ii)(Milk fat (on drybasis)- IS 11762) |
- |
1000 |
|
COMPLETE TESTING-12500/- |
| Cl-6.2.6, Table-3 (i)(Total solids, percent by mass, Min) |
- |
1000 |
|
COMPLETE TESTING-12500/- |
| Cl-6.2.6, Table-3 (ii)(Milk fat (on dry basis), percent by mass, Min) |
- |
1000 |
|
COMPLETE TESTING-12500/- |
| Cl-6.2.6, Table-3 (Iii)(Milk Protein (on dry basis), percent by
mass, Min) |
- |
1000 |
|
COMPLETE TESTING-12500/- |
| Cl-6.2.6, Table-3 (iv)(Titratable acidity (as lactic acid),
percent by mass, Max) |
- |
1000 |
|
COMPLETE TESTING-12500/- |
| Cl-6.2.6, Table-3 (v)(Sugar (sucrose), (on dry basis), percent by mass, Max) |
- |
1000 |
|
COMPLETE TESTING-12500/- |
| Cl-6.2.6, Table-3 (vi)(Total ash (on dry basis), percent by mass, Max) |
- |
1000 |
|
COMPLETE TESTING-12500/- |
| 6.2.2(Appearance and Colour) |
- |
250 |
|
COMPLETE TESTING-12500/- |
| 6.2.3(Odour and Flavour) |
- |
250 |
|
COMPLETE TESTING-12500/- |
| 6.2.4(Texture and Consistency) |
- |
250 |
|
COMPLETE TESTING-12500/- |
| 6.1.2(Appearance and colours- IS 9532-2023) |
- |
- |
|
- |
| 6.1.3(Odour and Flavour- IS 9532-2023) |
- |
- |
|
- |
| 6.1.4(Texture and Consistency- IS 9532-2023) |
- |
- |
|
- |
| Table 1 clause 6.1.6 (i)(Total solids-IS 11622) |
- |
- |
|
- |
| Table 1 clause 6.1.6 (iii)(Milk protein (on dry basis)- IS 11917) |
- |
- |
|
- |
| Table 1 clause 6.1.6 (iv)(Titrable acidity (as lactic acid)- 12 Of IS 1479 Part 1) |
- |
- |
|
- |
| Table 1 clause 6.1.6 (v)(Total ash (on dry basis) -Annex C of IS 14433) |
- |
- |
|
- |
| Table 2 clause 6.1.6 & 6.2.6 (vi)(Listeria monocytogenes
/g) |
- |
- |
|
- |
| Table 2 clause 6.1.6 & 6.2.6 (v)(Salmonella sp.) |
- |
- |
|
- |
| Table 2 clause 6.1.6 & 6.2.6 (ii)(Staphylococcus aureus(Coagulase positive)) |
- |
- |
|
- |
| Table 2 clause 6.1.6 & 6.2.6 (i)(Coliform count) |
- |
- |
|
- |
| Table 2 clause 6.1.6 & 6.2.6 (iv)(E.coli) |
- |
- |
|
- |
| Table 2 clause 6.1.6 & 6.2.6 (iii)(Yeast & Mould count) |
- |
- |
|
- |
| Table 1 clause 6.1.6 (ii)(Milk fat (on drybasis)- IS 11762) |
- |
- |
|
- |
| Cl-6.2.6, Table-3 (i)(Total solids, percent by mass, Min) |
- |
- |
|
- |
| Cl-6.2.6, Table-3 (ii)(Milk fat (on dry basis), percent by mass, Min) |
- |
- |
|
- |
| Cl-6.2.6, Table-3 (Iii)(Milk Protein (on dry basis), percent by
mass, Min) |
- |
- |
|
- |
| Cl-6.2.6, Table-3 (iv)(Titratable acidity (as lactic acid),
percent by mass, Max) |
- |
- |
|
- |
| Cl-6.2.6, Table-3 (v)(Sugar (sucrose), (on dry basis), percent by mass, Max) |
- |
- |
|
- |
| Cl-6.2.6, Table-3 (vi)(Total ash (on dry basis), percent by mass, Max) |
- |
- |
|
- |
| 6.2.2(Appearance and Colour) |
- |
- |
|
- |
| 6.2.3(Odour and Flavour) |
- |
- |
|
- |
| 6.2.4(Texture and Consistency) |
- |
- |
|
- |
|
17 Jun, 2027 |
- Included.w.e.f.02.01.2025 |
| 5981 |
Bharat Test House Pvt. Ltd. 1668 Sonipat
| 9168306
| IS 18739 (2024) |
Textiles Bedsheets Pillow cover and Blanket Cover Specification |
Textiles-Bedsheets, Pillow Cover and Blanket Cover-Specification |
55000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 3.1, Table-1(Fibre content) |
- |
1500 |
|
- |
| 3.1, Table-1(Count of Yarn-Warp) |
- |
300 |
|
- |
| 3.1, Table-1(Count of Yarn-Weft) |
- |
300 |
|
- |
| 3.1, Table-1(Weave) |
- |
500 |
|
- |
| 3.1, Table-1(Ends/cm) |
- |
500 |
|
- |
| 3.1, Table-1(Picks/cm) |
- |
500 |
|
- |
| 3.1, Table-1(Mass g/m2, Min) |
- |
500 |
|
- |
| 3.1, Table-1, (iii)(Tolerance) |
- |
500 |
|
- |
| 3.1, Table-2(Breaking Load on 5 cm × 20 cm Strip (Ravelled Strip Method)-Warpway) |
- |
1000 |
|
- |
| 3.1, Table-2(Breaking Load on 5 cm × 20 cm Strip (Ravelled Strip Method)-Weftway) |
- |
0 |
|
- |
| 3.1, Table-2(Tear Strength,-Warpway) |
- |
1000 |
|
- |
| 3.1, Table-2(Tear Strength,-Weftway) |
- |
0 |
|
- |
| 3.1, Table-2(Fabric Skew, Percent, Max) |
- |
1000 |
|
- |
| 3.1, Table-2(Fabric Bow, Percent, Max) |
- |
0 |
|
- |
| 3.1, Table-2("Dimensional Change, Percent,-
Warpway/Weftway") |
- |
1500 |
|
- |
| 3.1, Table-2(Scouring Loss Percent, Max) |
- |
5000 |
|
- |
| 3.1, Table-2(pH Value) |
- |
1000 |
|
- |
| 3.1, Table-2(Resistance to Pilling, For 1 000 Cycles, Min) |
- |
4000 |
|
- |
| 3.1, Table-3 (i)("Light:
a) Warp direction
b) Weft direction") |
- |
4000 |
|
- |
| 3.1, Table-3 (ii)("Washing:
a) Change in colour
b) Staining of adjacent fabrics") |
- |
4000 |
|
- |
| 3.1, Table-3 (iii)(Bleaching: Hypochlorite) |
- |
5000 |
|
- |
| 3.1, Table-3 (iv)("Rubbing:
a) Dry
b) Wet") |
- |
5000 |
|
- |
| 3.1, Table-3 (v)("Perspiration, acidic and alkaline:
a) Change in colour
b) Staining of adjacent fabrics") |
- |
5000 |
|
- |
| 3.2(Fabric Content) |
- |
0 |
|
- |
| 3.3(Freedom from Defects) |
- |
1000 |
|
- |
| 3.4(Sewing Thread) |
- |
1500 |
|
- |
| 3.5(Hems) |
- |
1000 |
|
- |
| 3.6(Sewing) |
- |
1000 |
|
- |
| 3.7, Table-4(- Size) |
- |
400 |
|
- |
| 3.7, Table-4(Width,cm) |
- |
300 |
|
- |
| 3.7, Table-4(Length, cm) |
- |
300 |
|
- |
| Cl-3.8(Soil Release Efficiency) |
- |
4500 |
|
- |
| Cl-3.9(Antimicrobial Activity) |
- |
0 |
|
- |
| Cl-3.10(Whiteness Index) |
- |
2000 |
|
- |
| 3.1, Table-1(Fibre content) |
- |
0 |
|
- |
| 3.1, Table-1(Count of Yarn-Warp) |
- |
0 |
|
- |
| 3.1, Table-1(Count of Yarn-Weft) |
- |
0 |
|
- |
| 3.1, Table-1(Weave) |
- |
0 |
|
- |
| 3.1, Table-1(Ends/cm) |
- |
0 |
|
- |
| 3.1, Table-1(Picks/cm) |
- |
0 |
|
- |
| 3.1, Table-1(Mass g/m2, Min) |
- |
0 |
|
- |
| 3.1, Table-1, (iii)(Tolerance) |
- |
0 |
|
- |
| 3.1, Table-2(Breaking Load on 5 cm × 20 cm Strip (Ravelled Strip Method)-Warpway) |
- |
0 |
|
- |
| 3.1, Table-2(Breaking Load on 5 cm × 20 cm Strip (Ravelled Strip Method)-Weftway) |
- |
0 |
|
- |
| 3.1, Table-2(Tear Strength,-Warpway) |
- |
0 |
|
- |
| 3.1, Table-2(Tear Strength,-Weftway) |
- |
0 |
|
- |
| 3.1, Table-2(Fabric Skew, Percent, Max) |
- |
0 |
|
- |
| 3.1, Table-2(Fabric Bow, Percent, Max) |
- |
0 |
|
- |
| 3.1, Table-2("Dimensional Change, Percent,-
Warpway/Weftway") |
- |
0 |
|
- |
| 3.1, Table-2(Scouring Loss Percent, Max) |
- |
0 |
|
- |
| 3.1, Table-2(pH Value) |
- |
0 |
|
- |
| 3.1, Table-2(Resistance to Pilling, For 1 000 Cycles, Min) |
- |
0 |
|
- |
| 3.1, Table-3 (i)("Light:
a) Warp direction
b) Weft direction") |
- |
0 |
|
- |
| 3.1, Table-3 (ii)("Washing:
a) Change in colour
b) Staining of adjacent fabrics") |
- |
0 |
|
- |
| 3.1, Table-3 (iii)(Bleaching: Hypochlorite) |
- |
0 |
|
- |
| 3.1, Table-3 (iv)("Rubbing:
a) Dry
b) Wet") |
- |
0 |
|
- |
| 3.1, Table-3 (v)("Perspiration, acidic and alkaline:
a) Change in colour
b) Staining of adjacent fabrics") |
- |
0 |
|
- |
| 3.2(Fabric Content) |
- |
0 |
|
- |
| 3.3(Freedom from Defects) |
- |
0 |
|
- |
| 3.4(Sewing Thread) |
- |
0 |
|
- |
| 3.5(Hems) |
- |
0 |
|
- |
| 3.6(Sewing) |
- |
0 |
|
- |
| 3.7, Table-4(- Size) |
- |
0 |
|
- |
| 3.7, Table-4(Width,cm) |
- |
0 |
|
- |
| 3.7, Table-4(Length, cm) |
- |
0 |
|
- |
| Cl-3.8(Soil Release Efficiency) |
- |
0 |
|
- |
| Cl-3.10(Whiteness Index) |
- |
0 |
|
- |
| Cl-3.9(Antimicrobial Activity) |
- |
0 |
|
- |
| 3.1, Table-1(Fibre content) |
- |
0 |
|
- |
| 3.1, Table-1(Count of Yarn-Warp) |
- |
0 |
|
- |
| 3.1, Table-1(Count of Yarn-Weft) |
- |
0 |
|
- |
| 3.1, Table-1(Weave) |
- |
0 |
|
- |
| 3.1, Table-1(Ends/cm) |
- |
0 |
|
- |
| 3.1, Table-1(Picks/cm) |
- |
0 |
|
- |
| 3.1, Table-1(Mass g/m2, Min) |
- |
0 |
|
- |
| 3.1, Table-1, (iii)(Tolerance) |
- |
0 |
|
- |
| 3.1, Table-2(Breaking Load on 5 cm × 20 cm Strip (Ravelled Strip Method)-Warpway) |
- |
0 |
|
- |
| 3.1, Table-2(Breaking Load on 5 cm × 20 cm Strip (Ravelled Strip Method)-Weftway) |
- |
0 |
|
- |
| 3.1, Table-2(Tear Strength,-Warpway) |
- |
0 |
|
- |
| 3.1, Table-2(Tear Strength,-Weftway) |
- |
0 |
|
- |
| 3.1, Table-2(Fabric Skew, Percent, Max) |
- |
0 |
|
- |
| 3.1, Table-2(Fabric Bow, Percent, Max) |
- |
0 |
|
- |
| 3.1, Table-2("Dimensional Change, Percent,-
Warpway/Weftway") |
- |
0 |
|
- |
| 3.1, Table-2(Scouring Loss Percent, Max) |
- |
0 |
|
- |
| 3.1, Table-2(pH Value) |
- |
0 |
|
- |
| 3.1, Table-2(Resistance to Pilling, For 1 000 Cycles, Min) |
- |
0 |
|
- |
| 3.1, Table-3 (i)("Light:
a) Warp direction
b) Weft direction") |
- |
0 |
|
- |
| 3.1, Table-3 (ii)("Washing:
a) Change in colour
b) Staining of adjacent fabrics") |
- |
0 |
|
- |
| 3.1, Table-3 (iii)(Bleaching: Hypochlorite) |
- |
0 |
|
- |
| 3.1, Table-3 (iv)("Rubbing:
a) Dry
b) Wet") |
- |
0 |
|
- |
| 3.1, Table-3 (v)("Perspiration, acidic and alkaline:
a) Change in colour
b) Staining of adjacent fabrics") |
- |
0 |
|
- |
| 3.2(Fabric Content) |
- |
0 |
|
- |
| 3.3(Freedom from Defects) |
- |
0 |
|
- |
| 3.4(Sewing Thread) |
- |
0 |
|
- |
| 3.5(Hems) |
- |
0 |
|
- |
| 3.6(Sewing) |
- |
0 |
|
- |
| 3.7, Table-4(- Size) |
- |
0 |
|
- |
| 3.7, Table-4(Width,cm) |
- |
0 |
|
- |
| 3.7, Table-4(Length, cm) |
- |
0 |
|
- |
| Cl-3.8(Soil Release Efficiency) |
- |
0 |
|
- |
| Cl-3.10(Whiteness Index) |
- |
0 |
|
- |
| Cl-3.9(Antimicrobial Activity) |
- |
0 |
|
- |
|
26 Jul, 2027 |
- Included w.e.f 05.05.2025
Exclusion: Cl-3.9 (Antimicrobial Activity) |
| 5982 |
Global Testing Laboratory Private limited, Ghaziabad
| 8184306
| IS 9968 : Part 1 (1988) |
Specification for elastomer insulatedcables: Part 1 for working voltages up to and including 1100 volts (First Revision) |
- |
10000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 3.1( Copper Cooduetor) |
- |
500 |
|
- |
| 3.2(Aluminium conductor) |
- |
500 |
|
- |
| 4.1(INSULATION : lnsulation for General Service) |
- |
500 |
|
- |
| 4.2(INSULATION : Heat Resisting insulation) |
- |
500 |
|
- |
| 4.3(INSULATION : Silicone Rubber Insulation) |
- |
500 |
|
- |
| 5.1(TAPE : Proofed Tape) |
- |
500 |
|
- |
| 5.2(TAPE : 2 Polyethyl_ Terephthalate ( PETP ) Tape or
Plastic: Tape or Any Other SlIIitable Tape ) |
- |
500 |
|
- |
| 5.3(TAPE : Giass Tape) |
- |
500 |
|
- |
| 6.1(FILLERS : ) |
- |
500 |
|
- |
| 7.1(BRAID : Textile Braid) |
- |
500 |
|
- |
| 7.2(BRAID : Glass Braid ) |
- |
500 |
|
- |
| 8.1(SHEATH : General Service Insulated Cables and Flexible
Cords) |
- |
500 |
|
- |
| 8.2(SHEATH :Heat Resisting Insulated Cables) |
- |
500 |
|
- |
| 9.1(PresenRtive Compound) |
- |
500 |
|
- |
| 9.2(Varnish) |
- |
500 |
|
- |
| 10( Conductor ) |
- |
500 |
|
- |
| 11(Separator tape) |
- |
500 |
|
- |
| 12.2(Insulation : Thickness of Insufatien) |
- |
1000 |
|
- |
| 12.4(Insulation : Allplication of Insulation) |
- |
500 |
|
- |
| 13(CORE IDENTiFICATlON) |
- |
500 |
|
- |
| 14(Tape) |
- |
500 |
|
- |
| 15(BRAIDING) |
- |
500 |
|
- |
| 16(COMPOUNDING AND VARNISHING) |
- |
500 |
|
- |
| 17(LAYING UP OF CORES) |
- |
500 |
|
- |
| 18( Binder tape) |
- |
500 |
|
- |
| 19.2(Sheath : Thickness of Sheath) |
- |
1000 |
|
- |
| 19.4( Sheath :Colour) |
- |
500 |
|
- |
| 20( Overall diameter) |
- |
1000 |
|
- |
| 21. (a)(Persulphate tests (for copper)) |
- |
1000 |
|
- |
| 21. (b)(Annealing Test (for coper)) |
- |
500 |
|
- |
| 21. (c)( Tensile Test (for aluminium)) |
- |
500 |
|
- |
| 21. (d)( Wrapping Test (for aluminium)) |
- |
500 |
|
- |
| 21. (e)(Conductor Resistance ) |
- |
1000 |
|
- |
| 21.1( Tensile strength ) |
- |
1000 |
|
- |
| 22.1( Elongation) |
- |
1000 |
|
- |
| 21.1(type test : Ageing In air oven) |
- |
2000 |
|
- |
| 21.1(type test : Ageing in air bomb) |
- |
2000 |
|
- |
| 21.1(type test : Ageing In oxygen
bomb) |
- |
2000 |
|
- |
| 21.1(type test : Hot set elongation) |
- |
2000 |
|
- |
| 21.1(type test : Tear resistance ) |
- |
1000 |
|
- |
| 22.2(type test :Insulauon resistance High voltage (water immersron ) test) |
- |
1000 |
|
- |
| 22.2(type test : Flammability test
( applicable to cables
finished With SE 3 and
SE 4 sheaths only)
) |
- |
1000 |
|
- |
| 21(Water absorption test) |
- |
3000 |
|
- |
| 23(identification) |
- |
500 |
|
- |
| Cl No. 4.1(Ageing in oxygen bomb - Elongation) |
- |
2000 |
|
- |
| Cl No. 4.1(Ageing in oxygen bomb - Tensile strength ) |
- |
2000 |
|
- |
| Cl No. 4.1(Ageing in air bomb - Elongation) |
- |
2000 |
|
- |
| Cl No. 4.1(Ageing in air bomb - Tensile strength ) |
- |
2000 |
|
- |
| Cl No. 4.1(Ageing in air oven - Elongation) |
- |
2000 |
|
- |
| Cl No. 4.1(Ageing in air oven - Tensile strength ) |
- |
2000 |
|
- |
| Cl No. 22.2(High Voltage Test (Water Immersion)) |
- |
1000 |
|
- |
| Cl No. 4.1(Insulation resistance) |
- |
1000 |
|
- |
| Cl No. 22.4, Appendix B (Flexing test for cords for use with electric iron ) |
- |
2000 |
|
- |
| Cl No. 22.2.2/22.2.3(High Voltage Test / Spark test) |
- |
1000 |
|
- |
| Cl No. 23.1, 23.2(Identification) |
- |
500 |
|
- |
| 21.1((f) Oil resistance) |
- |
2000 |
|
- |
| Cl.9.1(Compound and Varnish) |
- |
500 |
|
- |
| Cl.9.2(Compound and Varnish) |
- |
500 |
|
- |
| Cl.21.1 & Table 2 of IS: 6380-1984(Water Absorption Test) |
- |
3000 |
|
- |
| Cl.19.1(Application of Sheath) |
- |
500 |
|
- |
| Cl.21.1 & Table 3 of IS: 6380-1984(Physical Test on outer sheath (Without Ageing)) |
- |
1000 |
|
- |
| Cl.21.1 & Table 3 of IS: 6380-1984(Physical Test on outer sheath (Without Ageing)) |
- |
1000 |
|
- |
| Cl.21.1 & Table 3 of IS: 6380-1984(Physical Test on outer sheath (Without Ageing)) |
- |
1000 |
|
- |
| Cl.21.1 & Table 3 of IS: 6380-1984(Physical Test on outer sheath (After ageing in air oven)) |
- |
2000 |
|
- |
| Cl.21.1 & Table 3 of IS: 6380-1984(Physical Test on outer sheath (After ageing in air oven)) |
- |
2000 |
|
- |
| Cl.21.1 & Table 3 of IS: 6380-1984(Physical Test on outer sheath (After ageing in air Bomb )) |
- |
2000 |
|
- |
| Cl.21.1 & Table 3 of IS: 6380-1984(Physical Test on outer sheath (After ageing in air Bomb )) |
- |
2000 |
|
- |
| Cl.21.1 & Table 3 of IS: 6380-1984(Physical Test on outer sheath (Oil Resistance Test )) |
- |
2000 |
|
- |
| Cl.21.1 & Table 3 of IS: 6380-1984(Physical Test on outer sheath (Oil Resistance Test )
Variation on Elongation (Percentage)) |
- |
2000 |
|
- |
| Cl.21.1 & Table 3 of IS: 6380-1984(Physical Test on outer sheath (Hot Set Test)) |
- |
2000 |
|
- |
| Cl.21.1 & Table 3 of IS: 6380-1984(Physical Test on outer sheath (Hot Set Test)) |
- |
2000 |
|
- |
| Cl.21.1 & Table 2 of IS: 6380-1984(Insulation Resistance Test) |
- |
1000 |
|
- |
| Cl.21.1 & Table 2 of IS: 6380-1984(Insulation Resistance Test) |
- |
1000 |
|
- |
|
11 Mar, 2028 |
- - |
| 5983 |
CHOKSI LABORATORIES LIMITED, INDORE
| 8136916
| IS 17545 (2021) |
WHITE CEMENT BASED POLYMERIC PUTTY |
- |
18500 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4.5 , Table 1 , 1) , iii)(Setting time Initial, Min Final, Max) |
- |
1500 |
|
NA |
| 4.5 , Table 1 , 1) , ii)(Water retentivity, percent, min) |
- |
2500 |
|
NA |
| 4.6 , Table 2 , 1) , i)(Compressive strength, 28 days, Min) |
- |
3500 |
|
NA |
| 4.5 , Table 1 , 1) , i)(Tensile adhesion strength (avg. of min 3 readings) @14 days, N/mm2 , Min) |
- |
3500 |
|
NA |
| 4.5 , Table 1 , 1) , iv)(Polymer content (based on loss on ignition), percent by mass, Min) |
- |
2500 |
|
NA |
| 4.5 , Table 1 , 1) , v)(Degree of whiteness, percent, Min) |
- |
2500 |
|
NA |
| 4.5 , Table 1 , 1) , vi)(Cement content, percent, Min) |
- |
2500 |
|
NA |
|
31 Dec, 2026 |
- - |
| 5984 |
CHOKSI LABORATORIES LIMITED, INDORE
| 8136916
| IS 17425 (2020) |
Irrigation Equipment - Quick Coupled Polyethylene Pipes and Fittings for Sprinkler Irrigation Systems - Specification |
NM |
40500 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4.1.4(Carbon Black Content) |
- |
1000 |
|
NA |
| Cl.4.1.4(Carbon Black Di spersion) |
- |
500 |
|
NA |
| Cl.4.1.3(Den sity Test) |
- |
750 |
|
NA |
| Cl.4.1.3(MFR Test) |
- |
1250 |
|
NA |
| 4.1.3, Table 1,(iii)(Thermal stability) |
- |
1500 |
|
NA |
| 4.1.3, Table 1,(iv)(Volatile matter) |
- |
500 |
|
NA |
| 4.1.3, Table 1,(v)(Water content) |
- |
500 |
|
NA |
| 4.2(Metallic Couplers) |
- |
1500 |
|
NA |
| C. 4.1.1.1.2, IS 513 (P-1)-2016, Cl. 7.3, Table-3 , Grade O (CR1)(Carbon Content) |
- |
750 |
|
NA |
| C. 4.1.1.1.2, IS 513 (P-1)-2016, Cl. 7.3, Table-3 , Grade O (CR1)(Sulphur Content) |
- |
750 |
|
NA |
| C. 4.1.1.1.2, IS 513 (P-1)-2016, Cl. 7.3, Table-3 , Grade O (CR1)(Phosphorous Content) |
- |
750 |
|
NA |
| C. 4.1.1.1.2, IS 513 (P-1)-2016, Cl. 7.3, Table-3 , Grade O (CR1)(Manganese Content) |
- |
750 |
|
NA |
| C. 4.1.1.1.1, IS 737-2008, Cl. 6, Table-1 , Desig 31500(Silicon Content) |
- |
750 |
|
NA |
| C. 4.1.1.1.1, IS 737-2008, Cl. 6, Table-1 , Desig 31500(Aluminium Content) |
- |
750 |
|
NA |
| 5(Dimensions of pipe - i) Outside diameter) |
- |
500 |
|
NA |
| 5(Dimensions of pipe - ii) Wall thickness minimum) |
- |
500 |
|
NA |
| Cl.6.2.4(Workmanship and Appearance) |
- |
500 |
|
NA |
| 7.3(Quick Couple Fitting) |
- |
750 |
|
NA |
| Cl.7.2.3(Weld ability Test) |
- |
5000 |
|
NA |
| 7.2.1(Leakage Test) |
- |
1500 |
|
NA |
| Cl.7.2.2(Cl.7.2.2) |
- |
500 |
|
NA |
| 7.1.6(Corrected Density) |
- |
750 |
|
NA |
| 7.4(Fusion Compatibility Test- b) Acceptance test) |
- |
5000 |
|
NA |
| Cl.7.1.4(Tensile Test) |
- |
1500 |
|
NA |
| 7.1.3(Reversion) |
- |
1000 |
|
NA |
| Cl.7.1.2(Hydraulic Characteristic) |
- |
5000 |
|
NA |
| Cl.7.1.2(Hydraulic Characteristic) |
- |
5000 |
|
NA |
|
31 Dec, 2026 |
- - |
| 5985 |
CHOKSI LABORATORIES LIMITED, INDORE
| 8136916
| IS 4985 (2021) |
UNPLASTICIZED PVC PIPES FOR POTABLE WATER SUPPLIES SPECIFICATION Fourth Revision |
Type A and Type B |
22750 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 7.1.1.1(DIMENSIONS-PIPE-Mean O.D. (Minimum)) |
- |
250 |
|
NA |
| 7.1.1.1(DIMENSIONS-PIPE-Mean O.D. (Mamimum)) |
- |
0 |
|
NA |
| 7.1.1.1(DIMENSIONS-PIPE-Mean O.D. Variation) |
- |
0 |
|
NA |
| 7.1.1.2(DIMENSIONS-PIPE-O.D. at any Point (Minimum)) |
- |
250 |
|
NA |
| 7.1.1.2(DIMENSIONS-PIPE-O.D. at any Point (Maximum)) |
- |
0 |
|
NA |
| 7.1.2.1(DIMENSIONS-PIPE-Thickness(Minimum)) |
- |
250 |
|
NA |
| 7.1.2.1(DIMENSIONS-PIPE-Thickness(Maximum)) |
- |
0 |
|
NA |
| 7.1.2.1(DIMENSIONS-PIPE-Average Thickness) |
- |
0 |
|
NA |
| Cl- 7.2(Socket length (Take 4 reading & minimum will be reported)) |
- |
0 |
|
NA |
| 7.2.1.1-Table 3(DIMENSIONS-Socket-Sockets for solvent cement jointing-Minimum Length) |
- |
100 |
|
NA |
| 7.2.1.1-Table 3(DIMENSIONS-Socket-Sockets for solvent cement jointing-Diameter at mid point of the socket length (Minimum)) |
- |
250 |
|
NA |
| 7.2.1.1-Table 3(DIMENSIONS-Socket-Sockets for solvent cement jointing-Diameter at mid point of the socket length (Maximum)) |
- |
0 |
|
NA |
| 7.2.1.2-Table 4(DIMENSIONS-Sockets for elastomeric sealing ring joints-Socket inner Diameter) |
- |
100 |
|
NA |
| 7.2.1.2(a)-Table 5(DIMENSIONS-Sockets for elastomeric sealing ring joints-Minimum depth of engagement) |
- |
100 |
|
NA |
| 9.1(PIPE ENDS) |
- |
100 |
|
NA |
| 10.1(PHYSICAL AND CHEMICAL CHARACTERISTICS-Visual Appearance) |
- |
0 |
|
NA |
| 10.1.1(PHYSICAL AND CHEMICAL CHARACTERISTICS-Visual Appearance) |
- |
100 |
|
NA |
| 10.2(PHYSICAL AND CHEMICAL CHARACTERISTICS-Opacity) |
- |
350 |
|
NA |
| 10.4(PHYSICAL AND CHEMICAL CHARACTERISTICS- Reversion Test) |
- |
1250 |
|
NA |
| 10.5(PHYSICAL AND CHEMICAL CHARACTERISTICS- Vicat Softening Temperature) |
- |
950 |
|
NA |
| 10.6(PHYSICAL AND CHEMICAL CHARACTERISTICS- Density) |
- |
350 |
|
NA |
| 10.3(Effect on Water Test) |
- |
2300 |
|
NA |
| 10.7(Sulphated Ash Content) |
- |
950 |
|
NA |
| 11.1-Table 6(MECHANICAL PROPERTIES-Hydrostatic Pressure Test (Type Test)) |
- |
3050 |
|
NA |
| 11.1-Table 7(MECHANICAL PROPERTIES-Hydrostatic Pressure Test (Acceptance Test)-for Integral Sealing Ring Sockets) |
- |
1750 |
|
NA |
| 11.2(Resistance to External Blows at 0°C) |
- |
450 |
|
NA |
| 6.1.2(PVC Resin) |
- |
550 |
|
NA |
| 6.1.1(VCM Content) |
- |
2750 |
|
NA |
| 11.1-Table 7(MECHANICAL PROPERTIES-Hydrostatic Pressure Test (Type Test)-for Integral Sealing Ring Sockets) |
- |
3050 |
|
NA |
| 11.1-Table 6(MECHANICAL PROPERTIES-Hydrostatic Pressure Test (Acceptance Test)) |
- |
1750 |
|
NA |
| 11.1.1(MECHANICAL PROPERTIES-Hydrostatic Pressure Test (Acceptance Test)-for Plumbing pipes) |
- |
1750 |
|
NA |
|
31 Dec, 2026 |
- - |
| 5986 |
CHOKSI LABORATORIES LIMITED, INDORE
| 8136916
| IS 1328 (1996) |
Veneered Decorative Plywood -Specification |
Type 1 , Type 2 |
3900 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4.1(Grade - For BWR) |
- |
100 |
|
NA |
| 4.1(Grade - For MR) |
- |
100 |
|
NA |
| 4.2(Type - For Type 1) |
- |
100 |
|
NA |
| 4.2(Type - For Type 2) |
- |
100 |
|
NA |
| 7.1.1(Requirements - Open splits, checks or open joints - For Type 1 - Cl. 7.1.1) |
- |
100 |
|
NA |
| 7.2.1(Requirements - Open splits, checks or open joints - For Type 2 - Cl. 7.2.1) |
- |
100 |
|
NA |
| 7.1.2(Requirements - Other defects - For Type 1 - Cl. 7.1.2) |
- |
100 |
|
NA |
| 7.2.2(Requirements - Other defects - For Type 2 - Cl. 7.2.2.) |
- |
100 |
|
NA |
| 7.1.3(Requirements - Other Charcteristics and Manufacturing Defects - For Type 1 - Cl. 7.1.3) |
- |
100 |
|
NA |
| 7.2.3(Requirements - Other Charcteristics and Manufacturing Defects - For Type 2 - Cl. 7.2.3) |
- |
100 |
|
NA |
| 8(Dimensions & Tolerances - Length - Cl. 8) |
- |
100 |
|
NA |
| 8(Dimensions & Tolerances - Width - Cl. 8) |
- |
100 |
|
NA |
| 8(Dimensions & Tolerances - Thickness - Cl. 8) |
- |
100 |
|
NA |
| 8(Dimensions & Tolerances - Edge Straightness - Annexure C) |
- |
500 |
|
NA |
| 8(Dimensions & Tolerances - Squareness - Annexure C) |
- |
200 |
|
NA |
| 9(Finish - Cl. 9.1, 8.3) |
- |
100 |
|
NA |
| 9(Finish - Cl. 9.2, 8.3) |
- |
100 |
|
NA |
| 11(Tests - Moisture Content - Part 1 of IS 1734) |
- |
500 |
|
NA |
| 11(Tests - Water Resistance Test - Cl. 11.1.2.1 [for MR Grade]) |
- |
600 |
|
NA |
| 11(Tests - Water Resistance Test - Cl. 11.1.2.2 [for BWR Grade]) |
- |
600 |
|
NA |
|
31 Dec, 2026 |
- - |
| 5987 |
CHOKSI LABORATORIES LIMITED, INDORE
| 8136916
| IS 1659 (2004) |
Block boards - Specification (Fourth Revision) |
BWP GRADE-DECORATIVE/BWP-COMMERCIAL TYPE/MR-DECORATIVE |
6910 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 9.2.6(Spot test - Annexure L) |
- |
550 |
|
NA |
| 9.2.5(Modulus of elasticity - MINIMUM INDIVIDUAL - Annexure K) |
- |
550 |
|
NA |
| 9.2.5(Modulus of elasticity - AVERAGE - Annexure K) |
- |
550 |
|
NA |
| 9.2.5(Modulus of rupture - MINIMUM INDIVIDUAL - Annexure K) |
- |
550 |
|
NA |
| 9.2.5(Modulus of rupture - AVERAGE - Annexure K) |
- |
550 |
|
NA |
| 9.2.4(Mycological Test [for MR grade only] - Annexure J) |
- |
750 |
|
NA |
| 9.2.3(Adhesion of Plies - Annexure H) |
- |
250 |
|
NA |
| 9.2.2 (Resistance to water - Annexure G, Annexure H [For MR Grade]) |
- |
550 |
|
NA |
| 9.2.2 (Resistance to water - Annexure G, Annexure H [For BWP grade]) |
- |
550 |
|
NA |
| 9.2.1(Dimensional Changes caused by humidity Change in local planeness - Annexure F) |
- |
200 |
|
NA |
| 9.2.1(Dimensional Changes caused by humidity - Delamination - Annexure F) |
- |
200 |
|
NA |
| 9.2.1(Dimensional Changes caused by humidity - Change in thickness - at 40% RH - Annexure F) |
- |
200 |
|
NA |
| 9.2.1(Dimensional Changes caused by humidity - Change in Thickness - at 90% RH - Annexure F) |
- |
200 |
|
NA |
| 9.2.1(Dimensional Changes caused by humidity - Change in Length - at 40% RH - Annexure F) |
- |
200 |
|
NA |
| 9.2.1(Dimensional Changes caused by humidity - Change in Length - at 90% RH - Annexure F) |
- |
200 |
|
NA |
| 7.3(Dimensional Requirements - Variation in thickness - Annexure E) |
- |
100 |
|
NA |
| 7.3(Dimensional Requirements - Squareness - Annexure D) |
- |
180 |
|
NA |
| 7.3(Dimensional Requirements - Edge Straightness - Annexure D) |
- |
180 |
|
NA |
| 7.3(Dimensional Requirements - Thickness - Annexure E) |
- |
100 |
|
NA |
| 7.3(Dimensional Requirements - Width - 8.1.4) |
- |
100 |
|
NA |
| 7.3(Dimensional Requirements - Length - 8.1.4) |
- |
100 |
|
NA |
| 8.1.3, 6.3.3, IS 1328(Visual Inspection - Permissible Defects - IS 1328 [test method for DECORATIVE type]) |
- |
100 |
|
NA |
| 8.1.3, 6.3.3, IS 303(Visual Inspection - Permissible Defects - IS 303 [test method for COMMERCIAL type]) |
- |
100 |
|
NA |
| cl. 11(marking) |
- |
0 |
|
NA |
|
31 Dec, 2026 |
- - |
| 5988 |
CHOKSI LABORATORIES LIMITED, INDORE
| 8136916
| IS 4990 (2011) |
Plywood for concrete shuttering works - Specification (Third Revision) |
BWP/TYPE-1/TYPE-2/TYPE-3 |
7550 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4.0(Types) |
- |
100 |
|
NA |
| 7.2(DIMENSIONS &
TOLERANCES
) |
- |
150 |
|
NA |
| 7.2(DIMENSIONS &
TOLERANCES
) |
- |
150 |
|
NA |
| 7.3(DIMENSIONS &
TOLERANCES
) |
- |
150 |
|
NA |
| 7.4(DIMENSIONS &
TOLERANCES
) |
- |
100 |
|
NA |
| 7.4(DIMENSIONS &
TOLERANCES
) |
- |
50 |
|
NA |
| 8.1(WORKMANSHIP AND FINISH ) |
- |
50 |
|
NA |
| 8.3(WORKMANSHIP AND FINISH ) |
- |
50 |
|
NA |
| 10.1.1(MOISTURE CONTENT) |
- |
250 |
|
NA |
| 10.1.2, 10.1.2.1 (Table-1)(GLUE ADHESION IN DRY STATE) |
- |
250 |
|
NA |
| 10.1.2, 10.1.2.2(GLUE ADHESION IN DRY STATE) |
- |
200 |
|
NA |
| 10.1.3, 10.1.3.1.1 (Table-1)(RESISTANCE TO WATER TEST) |
- |
150 |
|
NA |
| 10.1.3, 10.1.3.1.2(RESISTANCE TO WATER TEST) |
- |
150 |
|
NA |
| 10.1.4(RESISTANCE TO WATER TEST) |
- |
150 |
|
NA |
| 10.1.5(MYCOLOGICAL TEST ) |
- |
250 |
|
NA |
| 10.1.5, 10.1.5.1 (Table-1)(MYCOLOGICAL TEST ) |
- |
250 |
|
NA |
| 10.1.5.2(MYCOLOGICAL TEST ) |
- |
150 |
|
NA |
| 10.1.6(TENSILE STRENGTH) |
- |
250 |
|
NA |
| 10.1.7 (Table-2)(STATIC BENDING STRENGTH) |
- |
250 |
|
NA |
| 10.1.7 (Table-2)(STATIC BENDING STRENGTH) |
- |
250 |
|
NA |
| 10.1.8 (Table-3)(WET BENDING STRENGTH) |
- |
250 |
|
NA |
| 10.1.8 (Table-3)(WET BENDING STRENGTH) |
- |
250 |
|
NA |
| 10.1.9(RETENTION OF PRESERVATIVE) |
- |
250 |
|
NA |
| 12, 12.1(MARKING) |
- |
100 |
|
NA |
| Cl. 10.1.8 (Table 3) (Cl. 10.1.8 (Table 3) (Modulus of Rupture: Across the Face Grain: Minimum Individual)) |
- |
100 |
|
NA |
| Cl. 10.1.8 (Table 3) (Cl. 10.1.8 (Table 3) (Modulus of Rupture: Across the Face Grain: Average)) |
- |
100 |
|
NA |
| Cl. 10.1.8 (Table 3) (Cl. 10.1.8 (Table 3) (Modulus of Rupture: Along the Face Grain: Minimum Individual)) |
- |
100 |
|
NA |
| Cl. 10.1.8 (Table 3) (Cl. 10.1.8 (Table 3) (Modulus of Rupture: Along the Face Grain: Average)) |
- |
100 |
|
NA |
| Cl. 10.1.8 (Table 3)(Cl. 10.1.8 (Table 3) (Modulus of Elasticity: Across the Face Grain: Minimum Individual)) |
- |
100 |
|
NA |
| Cl. 10.1.8 (Table 3) (Cl. 10.1.8 (Table 3) (Modulus of Elasticity: Across the Face Grain: Average)) |
- |
100 |
|
NA |
| Cl. 10.1.8 (Table 3) (Cl. 10.1.8 (Table 3) (Modulus of Elasticity: Along the Face Grain: Minimum Individual)) |
- |
100 |
|
NA |
| Cl. 10.1.8 (Table 3) (Cl. 10.1.8 (Table 3) (Modulus of Elasticity: Along the Face Grain: Average)) |
- |
100 |
|
NA |
| Cl. 10.1.7 (Table 2) (Cl. 10.1.7 (Table 2) (Modulus of Rupture: Across the Face Grain: Minimum Individual)) |
- |
100 |
|
NA |
| Cl. 10.1.7 (Table 2) (Cl. 10.1.7 (Table 2) (Modulus of Rupture: Across the Face Grain: Average)) |
- |
100 |
|
NA |
| Cl. 10.1.7 (Table 2) (Cl. 10.1.7 (Table 2) (Modulus of Rupture: Along the Face Grain: Minimum Individual)) |
- |
100 |
|
NA |
| Cl. 10.1.7 (Table 2) (Cl. 10.1.7 (Table 2) (Modulus of Rupture: Along the Face Grain: Average)) |
- |
100 |
|
NA |
| Cl. 10.1.7 (Table 2)(Cl. 10.1.7 (Table 2) (Modulus of Elasticity: Across the Face Grain: Minimum Individual)) |
- |
100 |
|
NA |
| Cl. 10.1.7 (Table 2) (Cl. 10.1.7 (Table 2) (Modulus of Elasticity: Across the Face Grain: Average)) |
- |
100 |
|
NA |
| Cl. 10.1.7 (Table 2) (Cl. 10.1.7 (Table 2) (Modulus of Elasticity: Along the Face Grain: Minimum Individual)) |
- |
100 |
|
NA |
| Cl. 10.1.7 (Table 2) (Cl. 10.1.7 (Table 2) (Modulus of Elasticity: Along the Face Grain: Average)) |
- |
100 |
|
NA |
| Cl. 10.1.6(Cl. 10.1.6 (Tensile Strength: Sum of the Tensile Strength in two directions)) |
- |
150 |
|
NA |
| Cl. 10.1.6 (Cl. 10.1.6 (Tensile Strength: Perpendicular to grain)) |
- |
150 |
|
NA |
| Cl. 10.1.6(Cl. 10.1.6 (Tensile Strength: Parallel to grain)) |
- |
100 |
|
NA |
| 10.1.9(Chem)(RETENTION OF PRESERVATIVE) |
- |
500 |
|
NA |
| cl. 10.1.2.1(glue adhesion in dry state - glue shear strength - AVERAGE) |
- |
150 |
|
NA |
| cl. 10.1.2.1(glue adhesion in dry state - glue shear strength - WOOD FAILURE, Average) |
- |
150 |
|
NA |
| cl. 10.1.3.1(resistance to water test - glue shear strength - AVERAGE) |
- |
150 |
|
NA |
| cl. 10.1.3.1(resistance to water test - glue shear strength - WOOD FAILURE, Average) |
- |
100 |
|
NA |
| cl. 10.1.5.1(mycological test - glue shear strength - AVERAGE) |
- |
100 |
|
NA |
| cl. 10.1.5.1(mycological test - glue shear strength - WOOD FAILURE, Average) |
- |
100 |
|
NA |
|
31 Dec, 2026 |
- - |
| 5989 |
CHOKSI LABORATORIES LIMITED, INDORE
| 8136916
| IS 303 (1989) |
Plywood for General Purposes - |
BWR AND MR/ AA TYPE/AB TYPE/BB TYPE |
6300 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 11.4, Table 4(Static Bending Strength - Modulus of Rupture - Across the Face Grain - Minimum Individual) |
- |
350 |
|
NA |
| 11.4, Table 4(Static Bending Strength - Modulus of Rupture - Across the Face Grain - Average) |
- |
350 |
|
NA |
| 11.4, Table 4(Static Bending Strength - Modulus of Rupture - Along the Face Grain - Minimum Individual) |
- |
350 |
|
NA |
| 11.4, Table 4(Static Bending Strength - Modulus of Rupture - Along the Face Grain - Average) |
- |
350 |
|
NA |
| 11.4, Table 4(Static Bending Strength - Modulus of Elasticity - Across the Face Grain - Minimum Individual) |
- |
350 |
|
NA |
| 11.4, Table 4(Static Bending Strength - Modulus of Elasticity - Across the Face Grain - Average) |
- |
350 |
|
NA |
| 11.4, Table 4(Static Bending Strength - Modulus of Elasticity - Along the Face Grain - Minimum Individual) |
- |
350 |
|
NA |
| 11.4, Table 4(Static Bending Strength - Modulus of Elasticity - Along the Face Grain - Average) |
- |
350 |
|
NA |
| 11.2.2(Glue Adhesion - Mycological test - 11.2.2, Part 7 of IS 1734 [for MR Garde only]) |
- |
500 |
|
NA |
| 11.2.1(Glue Adhesion - Water resistance test - 11.2.1.1 [for MR Grade]) |
- |
500 |
|
NA |
| 11.2.1(Glue Adhesion - Water resistance test - 11.2.1.1 [for BWR Grade]) |
- |
500 |
|
NA |
| 11.3(Moisture Content - Part 1 of IS 1734) |
- |
350 |
|
NA |
| 8(Dimensions & Tolerances - Edge Straightness - Annexure C) |
- |
200 |
|
NA |
| 8(Dimensions & Tolerances - Squareness - Annexure C) |
- |
200 |
|
NA |
| 8(Dimensions & Tolerances - Thickness - Cl. 8) |
- |
100 |
|
NA |
| 8(Dimensions & Tolerances - Width - Cl. 8) |
- |
100 |
|
NA |
| 8(Dimensions & Tolerances - Length - Cl. 8) |
- |
100 |
|
NA |
| 9(Workmanship and Finish - Cl.9, 8.3, Annexure C) |
- |
100 |
|
NA |
| 9(Workmanship and Finish - Cl.9, 8.3, Annexure C) |
- |
0 |
|
NA |
| 5.2, Table 1, Table 2(Quality Requirements - Cl. 5.2) |
- |
250 |
|
NA |
| 5.1(Type - For BB Type) |
- |
100 |
|
NA |
| 5.1(Type - For AB Type) |
- |
100 |
|
NA |
| 5.1(Type - For AA Type) |
- |
100 |
|
NA |
| 4(Grade - For MR grade) |
- |
100 |
|
NA |
| 4(Grade - For BWR grade) |
- |
100 |
|
NA |
| cl. 13.1(marking) |
- |
100 |
|
NA |
|
31 Dec, 2026 |
- - |
| 5990 |
CHOKSI LABORATORIES LIMITED, INDORE
| 8136916
| IS 15410 (2003) |
Containers for packaging of natural mineral water and packaged drinking water - Specification |
- |
9900 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4.0 (chem)(MATERIAL) |
- |
250 |
|
NA |
| 4.6.2(TRANSPARANCY) |
- |
250 |
|
NA |
| 4.6.3(LEAKAGE TEST) |
- |
200 |
|
NA |
| 4.6.4(DROP TEST) |
- |
200 |
|
NA |
| 4.6.5(MIGRATION TEST) |
- |
350 |
|
NA |
| 4.6.6(PORTABILITY TEST) |
- |
550 |
|
NA |
| 4.6.5.1 (chem)(Colour migration (Caps)) |
- |
500 |
|
NA |
| 4.6.3, clause 6 of IS:2798:1998(Leakage test- c. Air pressure leakage) |
- |
100 |
|
NA |
| 4.6.3, clause 6 of IS:2798:1998(Leakage test- b. Vibration leakage) |
- |
100 |
|
NA |
| 4.6.3, clause 6 of IS:2798:1998(Leakage test- a. Closure leakage ) |
- |
100 |
|
NA |
| 4.5, IS:2798:1998(Wall thickness- Bottom, in mm) |
- |
100 |
|
NA |
| 4.5, IS:2798:1998(Wall thickness- Middle , in mm) |
- |
100 |
|
NA |
| Cl. 4.5(Cl. 4.5 Wall Thickness (Top)) |
- |
100 |
|
NA |
| Cl. 4.4 (a)(Capacity) |
- |
100 |
|
NA |
| 4.3(Workmanship, Finish & Appearance) |
- |
100 |
|
NA |
| 4.2 (chem)(Design, Shape & Dimension) |
- |
100 |
|
NA |
| 4.4 , clause 5 of IS:2798:1998(Brimful capacity in ml) |
- |
200 |
|
NA |
| Cl. 4.6.5 (chem)(Cl. 4.6.5 Overall migration (Caps)) |
- |
500 |
|
NA |
| Cl.4.6.7.2 and 4.6.7.3, Table 3, (i)(Barium) |
- |
350 |
|
NA |
| Cl.4.6.7.2 and 4.6.7.3, Table 3, (ii)(Cobalt) |
- |
350 |
|
NA |
| Cl.4.6.7.2 and 4.6.7.3, Table 3, (iii)(Copper) |
- |
350 |
|
NA |
| Cl.4.6.7.2 and 4.6.7.3, Table 3, (iv)(Iron) |
- |
350 |
|
NA |
| Cl.4.6.7.2 and 4.6.7.3, Table 3, (v)(Lithium) |
- |
350 |
|
NA |
| CL 4.6.7.2 and 4.6.7.3, Table 3 (vi)(Manganese) |
- |
350 |
|
NA |
| Cl.4.6.7.2 and 4.6.7.3, Table 3, (vii)(Zinc) |
- |
350 |
|
NA |
| Cl.4.6.7.2 and 4.6.7.3, Table 3, (viii)(Antimony) |
- |
350 |
|
NA |
| Cl.4.6.7.2 and 4.6.7.3, Table 3, (ix)(Phthalic acid, bis(2-ethylhexyl) ester (DEHP)) |
- |
2500 |
|
NA |
| 4.6.5 , IS:9845:1998 (chem)(Migration- b. Amount of extractive) |
- |
350 |
|
NA |
| 4.6.5 , IS:9845:1998 (chem)(Migration- a. Amount of extractive) |
- |
350 |
|
NA |
|
31 Dec, 2026 |
- - |
| 5991 |
CHOKSI LABORATORIES LIMITED, INDORE
| 8136916
| IS 1489 (Part 1) (2015) |
Portland pozzolana cement - Specification: Part 1 fly Ash Based |
- |
7500 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 7 -Table 2- vi(Drying Shrinkage- IS 4031 Part 10) |
- |
600 |
|
- |
| 7 -Table 2- iv- c(Compressive Strength At 672 hrs ± 4 hr - IS 4031 Part 6) |
- |
400 |
|
- |
| 7 -Table 2- iv- b(Compressive Strength At 168 hrs ± 2 hr - IS 4031 Part 6) |
- |
400 |
|
- |
| 7 -Table 2- iv- a(Compressive Strength At 72 hrs ± 1 hr - IS 4031 Part 6) |
- |
400 |
|
- |
| 7 -Table 2-iii- b(Setting Time Final- 4031 Part 5) |
- |
300 |
|
- |
| 7 -Table 2- iii- a(Setting Time Initial- 4031 Part 5) |
- |
300 |
|
- |
| 7 -Table 2- ii- b(Expansion after aeration- 4031 Part 3) |
- |
300 |
|
- |
| 7 -Table 2- ii- b(Expansion by Autoclave- 4031 Part 3) |
- |
300 |
|
- |
| 7 -Table 2- ii- a(Expansion after aeration - 4031 Part 3) |
- |
300 |
|
- |
| 7 -Table 2- ii- a(Expansion by Le Chatelier- 4031 Part 3) |
- |
300 |
|
- |
| 7 -Table 2- i(Fineness 4031 Part 2) |
- |
900 |
|
- |
| 6 - Table - 1 i(Insoluble residue - Cl 7.4 of IS 4032:1985) |
- |
600 |
|
- |
| 6 - Table - 1 ii(Magnesia - Cl 7.2 of IS 4032:1985) |
- |
600 |
|
- |
| 6 - Table - 1 iii(Total Sulphur Content calculated as Sulphuric Anhydride (SO3) - Cl 7.3 of IS 4032:1985) |
- |
600 |
|
- |
| 6 - Table - 1 iv(Loss on ignition - Cl 7.1 of IS 4032:1985) |
- |
600 |
|
- |
| 6 - Table - 1 v(Chloride content - Cl 4.13 of IS 4032:1985) |
- |
600 |
|
- |
| 6 - Table - 1 vi( Alkali content as (Na2O + 0.658 K2O) - Cl 4.11 of IS 4032:1985) |
- |
0 |
|
- |
|
31 Dec, 2026 |
- - |
| 5992 |
CHOKSI LABORATORIES LIMITED, INDORE
| 8136916
| IS 1165 (2022) |
WHOLE MILK POWDER - SPECIFICATION (Sixth Revision of IS 1165) |
- |
26500 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 3.1(Description) |
- |
0 |
|
- |
| 3.2(Flavour and Taste) |
- |
0 |
|
- |
| 3.4.5(Moisture) |
- |
0 |
|
- |
| 3.4.5(Total solids) |
- |
0 |
|
- |
| 3.4.5(Fat) |
- |
0 |
|
- |
| 3.4.5(Insolubility index) |
- |
0 |
|
- |
| 3.4.5(Total ash) |
- |
0 |
|
- |
| 3.4.5(Titratable acidity (lactic acid)) |
- |
0 |
|
- |
| 3.5(Bacterial count) |
- |
0 |
|
- |
| 3.5.2(Coliform count) |
- |
0 |
|
- |
| 3.5.3(Staphylococcus Aureus) |
- |
0 |
|
- |
| 3.5.4(Salmonella) |
- |
0 |
|
- |
| 3.5.5(Shigella) |
- |
0 |
|
- |
| Clause 3.5,Table 1 ,Sl No i)(Moisture) |
- |
500 |
|
- |
| Clause 3.5,Table 1 ,Sl No ii)(Total solids) |
- |
500 |
|
- |
| Clause 3.5,Table 1 ,Sl No iii)(Milk fat) |
- |
500 |
|
- |
| Clause 3.5,Table 1 ,Sl No iv)(Milk protein in milk solids not fat) |
- |
500 |
|
- |
| Clause 3.5,Table 1 ,Sl No v)(Insolubility index) |
- |
500 |
|
- |
| Clause 3.5,Table 1 ,Sl No vi)(Total ash(on dry basis)) |
- |
500 |
|
- |
| Clause 3.5,Table 1 ,Sl No vii)(Titratable acidity (lactic acid),) |
- |
500 |
|
- |
| Clause 3.5,Table 1 ,Sl No viii)(Scorched particle) |
- |
500 |
|
- |
| Clause 3.5,Table 2 ,Sl No i)(Aerobic plate count) |
- |
1000 |
|
- |
| Clause 3.5,Table 2 ,Sl No ii)(Coliform Count) |
- |
1000 |
|
- |
| Clause 3.5,Table 2 ,Sl No iii)(Staphylococcus aureus(Coagulase positive)) |
- |
1000 |
|
- |
| Clause 3.5,Table 2 ,Sl No v)(Salmonella sp) |
- |
1000 |
|
- |
| Clause 3.5,Table 2 ,Sl No vi)(Listeria monocytogenes) |
- |
1000 |
|
- |
| Clause 3.5,Table 2 ,Sl No iv)(Yeast and mould count) |
- |
1000 |
|
- |
| Clause 3.5,Table 2 ,Sl No vii)(Bacillus cereus) |
- |
1000 |
|
- |
| Clause 3.5,Table 2 ,Sl No viii)(Sulphite reducing clostridia) |
- |
1000 |
|
- |
| Clause 3.5,Table 2 ,Sl No ix)(E. coli) |
- |
1000 |
|
- |
| Clause 3.7,Table 3, Sl No i)(Lead) |
- |
1000 |
|
- |
| Clause 3.7,Table 3 ,Sl No ii)(Arsenic) |
- |
1000 |
|
- |
| Clause 3.7,Table 3,Sl No iii)(Aflaoxin) |
- |
2500 |
|
- |
| Clause 3.7,Table 3, Sl No iv)(Melamine) |
- |
2500 |
|
- |
| 3.1(Discription) |
- |
0 |
|
- |
| 3.2(Flavour and Taste) |
- |
250 |
|
- |
| 3.3(extraneous matter) |
- |
250 |
|
- |
| 3.6(Pesticide residue) |
- |
6000 |
|
- |
|
31 Dec, 2026 |
- - |
| 5993 |
CHOKSI LABORATORIES LIMITED, INDORE
| 8136916
| IS 1011 (2002) |
Biscuits - Specification (Fourth Revision) |
- |
3280 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 6.1(General Requirement) |
- |
0 |
|
- |
| 6.3 Table 2 i (Moisture) |
- |
750 |
|
- |
| 6.3 Table 2 ii (Acid insoluble ash (on dry basis)) |
- |
1510 |
|
- |
| 6.3 Table 2 iii (Acidity of extracted fat (as oleic acid)) |
- |
1020 |
|
- |
|
31 Dec, 2026 |
- - |
| 5994 |
CHOKSI LABORATORIES LIMITED, INDORE
| 8136916
| IS 1166 (2022) |
SWEETENED CONDENSED MILK, SWEETENED CONDENSED PARTLY SKIMMED MILK, SWEETENED CONDENSED SKIMMED MILK AND SWEETENED CONDENSD HIGH FAT MILK- SPECIFICATION (Third Revision of IS 1166) |
- |
22600 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Table 1 (i) (Apendix B)(Total milk solids -Condensed Milk) |
- |
0 |
|
- |
| Table 1 (i) (Apendix B)(Total milk solids - Partly Skimmed Condenied Milk) |
- |
0 |
|
na |
| Table 1 (i) (Apendix B)(Total milk solids - Skirmned Condensed Milk) |
- |
0 |
|
na |
| Table 1 (ii) (IS : 11762-
1986)(Fat -Condensed Milk) |
- |
0 |
|
- |
| Table 1 (ii) (IS : 11762-
1986)(Fat -Partly Skimmed Condenied Milk) |
- |
0 |
|
NA |
| Table 1 (ii) (IS : 11762-
1986)(Fat -Skirmned Condensed Milk) |
- |
0 |
|
NA |
| Table 1 (iii) (Apendix C)(Sucrose -Condensed Milk) |
- |
0 |
|
NA |
| Table 1 (iii) (Apendix C)(Sucrose -Partly Skimmed Condenied Milk) |
- |
0 |
|
NA |
| Table 1 (iii) (Apendix C)(Sucrose -Skirmned Condensed Milk) |
- |
0 |
|
NA |
| Table 1 (vi) (Apendix D)(Titratable acidity (as lactic acid) -Condensed Milk) |
- |
0 |
|
NA |
| Table 1 (vi) (Apendix D)(Titratable acidity (as lactic acid) -Partly Skimmed Condenied Milk) |
- |
0 |
|
NA |
| Table 1 (vi) (Apendix D)(Titratable acidity (as lactic acid) -Skirmned Condensed Milk) |
- |
0 |
|
NA |
| Table 1 (v) (Apendix E)(Accelerated starage test -Condensed Milk) |
- |
0 |
|
- |
| Table 1 (v) (Apendix E)(Accelerated starage test -Partly Skimmed Condenied Milk) |
- |
0 |
|
- |
| Table 1 (v) (Apendix E)(Accelerated starage test -Skirmned Condensed Milk) |
- |
0 |
|
- |
| 4.1.10.1(Bacterial Count) |
- |
0 |
|
- |
| Clause no 4.1.10.2(coliform count) |
- |
0.01 |
|
- |
| Clause no 4.1.10.4(S.aureus) |
- |
0.01 |
|
- |
| Cl.5.1.10.1(Salmonella IS 5887 Part 3) |
- |
0 |
|
- |
| Cl.5.1.10.1(Shigella IS 5887 Part 7) |
- |
0 |
|
NA |
| Clause no 4.1.10.5(E.coli) |
- |
0.01 |
|
- |
| Clause no 4.1.10.3(Yeast & Mould count) |
- |
0 |
|
- |
| Clause no 4.1.1(Description) |
- |
0 |
|
- |
| 4.1.4(Colour) |
- |
0 |
|
- |
| ( Clauses 4.1 and 4.7) Tabel 1 (i)(Total milk solid) |
- |
500 |
|
- |
| 4.1,Table 1(ii)(Milk Fat -IS 11721) |
- |
500 |
|
- |
| 4.1,Table 1(iv)(Milk protein in milk solids not fat IS -11917) |
- |
500 |
|
- |
| 4.1,Table 1(iii)(Milk solid not fat- IS1166) |
- |
500 |
|
- |
| 4.1,Table 1(v)(Accelerated Storage Test -IS 1166) |
- |
2000 |
|
- |
| "4.7 Table 2 (i) "(Aerobic plate count-IS 5402 (Part 1)) |
- |
800 |
|
- |
| "4.7 Table 2 (ii) "(Coliform count-IS 5401 (Part 1)) |
- |
800 |
|
- |
| "4.7 Table 2 (iii) "(Staphylococcuus aureus-IS 5887 (Part 8/Sec-1)) |
- |
800 |
|
- |
| "4.7 Table 2 (v) "(Salmonella sp.-IS 5887 (Part 3/Sec-1)) |
- |
800 |
|
- |
| "4.7 Table 2 (vi) "(Listeria monocytogenes-IS 14988 (Part 1)) |
- |
800 |
|
- |
| "4.7 Table 2 (vii) "(Escherichia coli-IS 5887 (Part 1)) |
- |
800 |
|
- |
| "4.7 Table 2 (iv) "(Yeast & mould count-IS 5403) |
- |
800 |
|
- |
| 4.9,Table 3(i)(Lead -IS 12074) |
- |
1000 |
|
- |
| 4.9,Table 3(ii)(Arsenic - IS 11124) |
- |
1000 |
|
- |
| 4.9,Table 3(iii)(Aflatoxin M1 - ISO 14501 or ISO 14674 or any other international validated method) |
- |
2000 |
|
- |
| 4.9,Table 3(iv)(Melamine - IS 16195) |
- |
2000 |
|
- |
| 4.2(Taste , Flavour,Colour & Odour. Free from rancid , fruity , moldy , tallowy , cooked , sour, sandy and any other objectionable odour and taste -IS 1166) |
- |
500 |
|
- |
| 4.6(Size of lactose crystals- IS 1166) |
- |
500 |
|
- |
| 4.8(Pesticide Residues) |
- |
6000 |
|
- |
|
31 Dec, 2026 |
- - |
| 5995 |
CHOKSI LABORATORIES LIMITED, INDORE
| 8136916
| IS 269 (2015) |
Ordinary portland cement - Specification (Sixth Revision) |
- |
9500 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 7 Table-3 iv c(Compressive Strength At 672 hrs ± 4 hr - IS 4031 Part 6) |
- |
250 |
|
- |
| 7 Table-3 iv c(Compressive Strength At 672 hrs ± 4 hr - IS 4031 Part 6) |
- |
250 |
|
- |
| 7 Table-3 iv c(Compressive Strength At 672 hrs ± 4 hr - IS 4031 Part 6) |
- |
250 |
|
- |
| 7 Table-3 iv b(Compressive Strength At 168 hrs ± 2 hr - IS 4031 Part 6) |
- |
250 |
|
- |
| 7 Table-3 iv b(Compressive Strength At 168 hrs ± 2 hr - IS 4031 Part 6) |
- |
250 |
|
- |
| 7 Table-3 iv a(Compressive Strength At 72 hrs ± 1 hr - IS 4031 Part 6) |
- |
250 |
|
- |
| 7 Table-3 iv a(Compressive Strength At 72 hrs ± 1 hr - IS 4031 Part 6) |
- |
250 |
|
- |
| 7 Table-3 iv a(Compressive Strength At 72 hrs ± 1 hr - IS 4031 Part 6) |
- |
250 |
|
- |
| 7 Table-3 iii b(Setting Time Final) |
- |
500 |
|
- |
| 7 Table-3 iii a(Setting Time Initial) |
- |
500 |
|
- |
| 7 Table-3 ii b(Expansion after aeration) |
- |
250 |
|
- |
| 7 Table-3 ii b(Expansion by Autoclave) |
- |
500 |
|
- |
| 7 Table-3 ii a(Expansion after aeration) |
- |
250 |
|
- |
| 7 Table-3 i.(Fineness) |
- |
1000 |
|
- |
| 6.1 Table-2 vii(Chloride content) |
- |
100 |
|
- |
| 6.1 Table-2 vi(Loss on ignition) |
- |
200 |
|
- |
| 6.1 Table-2 v(Total Sulphur Content calculated as Sulphuric Anhydride) |
- |
400 |
|
- |
| 6.1 Table-2 iv(Magnesia) |
- |
400 |
|
- |
| 6.1 Table-2 iii.(Insoluble residue) |
- |
400 |
|
- |
| 6.1 Table-2 ii.(Ratio of percentage of alumina to that of iron oxide) |
- |
500 |
|
- |
| 6.1 Table-2 i.(Ratio of percentage of lime to percentage of silica, alumina and iron oxide) |
- |
400 |
|
- |
| 6 - Table - 1 viii(Alkali content as (Na2O + 0.658 K2O) - Cl 4.11 of IS 4032:1985) |
- |
200 |
|
- |
| 6.1 Table-2 viii(Alkali content) |
- |
200 |
|
- |
| 6 - Table - 1 vii(Chloride content - Cl 4.13 of IS 4032:1985) |
- |
400 |
|
- |
| 6 - Table - 1 vi(Loss on ignition - Cl 4.2 of IS 4032:1985) |
- |
250 |
|
- |
| 6 - Table - 1 v(Total Sulphur Content calculated as Sulphuric Anhydride (SO3) - Cl 4.9 of IS 4032:1985) |
- |
200 |
|
- |
| 6 - Table - 1 iv(Magnesia - Cl 4.8 of IS 4032:1985) |
- |
200 |
|
- |
| 6 - Table - 1 iii(Insoluble residue - Cl 4.10 of IS 4032:1985) |
- |
200 |
|
- |
| 6 - Table - 1 ii(Ratio of percentage of alumina to that of iron oxide - Cl 4 of IS 4032:1985) |
- |
250 |
|
- |
| 6 - Table - 1 i(Ratio of percentage of lime to percentages of silica, alumina and iron oxide - Cl 4 of IS 4032:1985) |
- |
200 |
|
- |
|
31 Dec, 2026 |
- - |
| 5996 |
CHOKSI LABORATORIES LIMITED, INDORE
| 8136916
| IS 2831 (2012) |
Carbon steel cast billet ingots, billets, blooms and slabs for re-rolling into structural steel (Ordinary Quality) - Specification (Fourth Revision) |
- |
4500 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl. 6.1, Table 1(Carbon- IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
270 |
|
- |
| Cl. 6.1, Table 1(Manganese- IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
270 |
|
- |
| Cl. 6.1, Table 1(Sulphur- IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
270 |
|
- |
| Cl. 6.1, Table 1(Phosphorus- IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
270 |
|
- |
| Cl. 6.1, Table 1(Silicon- IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
270 |
|
- |
| Cl. 6.1, Table 1(Aluminium- IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
270 |
|
- |
| Cl. 6.1, Table 1(Nitrogen- IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
270 |
|
- |
| Cl. 6.1, Table 1(Copper- IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
270 |
|
- |
| Cl. 6.1, Table 1(Niobium- IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
270 |
|
- |
| Cl. 6.1, Table 1(Vanadium- IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
270 |
|
- |
| Cl. 6.1, Table 1(Titanium- IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
270 |
|
- |
| Clause 6.1.1(Carbon Equivalent (CE)) |
- |
260 |
|
- |
| Table 1 Note 2(Nb+V+Ti) |
- |
270 |
|
- |
| Table 1 Note 2(Any Instrumental Method/Chemical Method) |
- |
270 |
|
- |
| 9( FREEDOM FROM DEFECTS) |
- |
350 |
|
- |
| 11(Dimensions) |
- |
400 |
|
- |
| 10.2(Bend) |
- |
250 |
|
- |
|
31 Dec, 2026 |
- - |
| 5997 |
CHOKSI LABORATORIES LIMITED, INDORE
| 8136916
| IS 13334 : Part 2 (2014) |
Skimmed milk powder - Specification: Part 2 extra grade (First Revision) |
Extra Grade |
18000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Table 1 (i)(Moisture (IS 116231or 16072)) |
- |
500 |
|
- |
| Table 1 (ii)(Milk protein in milk solids not fat (IS 72192)) |
- |
500 |
|
- |
| Table 1 (iii)(Milk fat (IS 117213) or Annex B) |
- |
500 |
|
- |
| Table 1 (iv)(Insolubility index (IS 12759)) |
- |
500 |
|
- |
| Table 1 (v)(Total ash (on dry basis), Annex B of IS 14433) |
- |
500 |
|
- |
| Table 1 (vi)(Titratable acidity (IS 11766)) |
- |
500 |
|
- |
| Table 1 (vii)(Lactate content (IS 11202)) |
- |
500 |
|
- |
| Table 1 (viii)(Scorched particles (equivalent to Disc B) (IS 13500)) |
- |
500 |
|
- |
| Table 1 (ix)(Bacterial count (IS 5402)) |
- |
500 |
|
- |
| Table 1 (x)(Coliform count (IS 5401 - Part 1)) |
- |
500 |
|
- |
| Table 1 (xi)(Escherichia coli (IS 5887 - Part 1)) |
- |
500 |
|
- |
| Table 1 (xii)(Coagulase positive Staphylococcus aureus (IS 5887 - Part 2)) |
- |
500 |
|
- |
| Table 1 (xiii)(Salmonella (IS 5887 - Part 3)) |
- |
500 |
|
- |
| Table 1 (xiv)(a)(Spore Count: a)Aerobic (Bacillus cereus) Type m (IS 5887 - Part 6)) |
- |
1000 |
|
- |
| Table 1 (xiv)(a)(Spore Count: a) Aerobic (Bacillus cereus) Type M (IS 5887 - Part 6)) |
- |
1000 |
|
- |
| Table 1 (xiv)(b)(Spore Count: b) Anaerobic (Sulfite reducing Clostridia) Type m (ISO 15213 : 2003)) |
- |
1000 |
|
- |
| Table 1 (xiv)(b)(Spore Count: b) Anaerobic (Sulfite reducing Clostridia) Type M (ISO 15213 : 2003)) |
- |
1000 |
|
- |
| Table 1 (xv)(Listeria monocytogenes (IS 14988 - Part 2 : 2001)) |
- |
1000 |
|
- |
| Clause no 5.4(Flavour) |
- |
0 |
|
- |
| Clause no 5.2(freedom from extraneous matter) |
- |
0 |
|
- |
| Clause no 4(Description) |
- |
0 |
|
- |
| 5.8(Pesticides, Heavy metals, toxins & contaminants) |
- |
6000 |
|
- |
| 5.1(freedom from preservatives, neutralizers and adulterants) |
- |
0 |
|
- |
|
31 Dec, 2026 |
- - |
| 5998 |
CHOKSI LABORATORIES LIMITED, INDORE
| 8136916
| IS 14433 (2022) |
INFANT MILK SUBSTITUTES - SPECIFICATION (Second Revision of IS 14433) |
- |
45250 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 6.9.1(Bacterial count) |
- |
1000 |
|
- |
| 6.9.2(Coliform count) |
- |
1000 |
|
- |
| 6.9.3(Escherichia coli) |
- |
1000 |
|
- |
| 6.9.4(Staphylococcus Aureus) |
- |
1000 |
|
- |
| 6.9.5(Salmonella and shigella) |
- |
0 |
|
- |
| 6.9.6(Yeast and mould count) |
- |
1000 |
|
- |
| 6.1(Moisture) |
- |
500 |
|
- |
| 6.1(Milk protein) |
- |
500 |
|
- |
| 6.1(Milk fat) |
- |
500 |
|
- |
| 6.1(Total fat) |
- |
500 |
|
- |
| 6.1(Total ash) |
- |
500 |
|
- |
| 6.1(Acid insoluble ash) |
- |
500 |
|
- |
| 6.1(Insolubility index) |
- |
500 |
|
- |
| 6.1(Vitamin A (as Retinol)) |
- |
1000 |
|
- |
| 6.1(Iron) |
- |
1000 |
|
- |
| 6.1(Lead) |
- |
1000 |
|
- |
| 6.1(Arsenic) |
- |
1000 |
|
- |
| 6.1(Tin) |
- |
1000 |
|
- |
| 6.1(Cadmium) |
- |
1000 |
|
- |
| 6.1(Added Vitamin D (expressed as chole-calciferol)) |
- |
1000 |
|
- |
| 6.1(Thiamin) |
- |
1000 |
|
- |
| 6.1(Niacin) |
- |
1000 |
|
- |
| 6.1(Riboflavin) |
- |
1000 |
|
- |
| 6.1(Vitamin B6) |
- |
1000 |
|
- |
| 6.1(Vitamin B12) |
- |
1000 |
|
- |
| 6.1(Folic acid) |
- |
1000 |
|
- |
| 6.1(Pentothenic acid) |
- |
1000 |
|
- |
| 6.1(Biotin ) |
- |
1000 |
|
- |
| 6.1(Vitamin C) |
- |
500 |
|
- |
| 6.1(Vitamin K) |
- |
1000 |
|
- |
| 6.1(Calcium) |
- |
1000 |
|
- |
| 6.1(Phosphorus) |
- |
1000 |
|
- |
| 6.1(Iodine) |
- |
500 |
|
- |
| 6.1(Copper) |
- |
1000 |
|
- |
| 6.1(Manganese) |
- |
1000 |
|
- |
| 6.1(Zinc) |
- |
1000 |
|
- |
| 6.1(Sodium) |
- |
1000 |
|
- |
| 6.1(Potassium) |
- |
1000 |
|
- |
| 6.1(Chloride) |
- |
500 |
|
- |
| 6.1(Magnesium) |
- |
1000 |
|
- |
| 6.1(Choline) |
- |
0 |
|
- |
| 6.1(Selenium) |
- |
1000 |
|
- |
| 5(Description) |
- |
0 |
|
- |
| 6.3(Flavour taste and odour) |
- |
0 |
|
- |
| 6.4(Scorched particles) |
- |
0 |
|
- |
| 6.5(Linoleate) |
- |
1500 |
|
- |
| 6.1(Vitamin E ( as alpha tocopherol compounds)) |
- |
1000 |
|
- |
| 6.5(Vitamin E (for type 2 only)) |
- |
1000 |
|
- |
| 6.10.1(Protein content) |
- |
500 |
|
- |
| 6.10.1(Mineral content) |
- |
0 |
|
- |
| 6.10.1(Calcium:phosphorus ratio) |
- |
0 |
|
- |
| 6.10.1(Sodium, Potassium & Chloride) |
- |
0 |
|
- |
| 6.10.1(Whey:casein ratio) |
- |
500 |
|
- |
| Clause no 6.1(freedom from extraneous matter) |
- |
0 |
|
- |
| 6.10 vi b(Solubility percent) |
- |
1000 |
|
- |
| Clause 5.10,Table 3, Sl No i)(Aerobic plate count) |
- |
1000 |
|
- |
| Clause 5.10,Table 3, ,Sl No ix)(Enterobacteriaceae) |
- |
1000 |
|
- |
| Clause 5.10,Table 3, ,Sl No x)(Enterobacter sakazakii ( Cronobacter sp.)) |
- |
1000 |
|
- |
| Clause 5.10,Table 3, ,Sl No iii)(Staphylococcus aureus) |
- |
1000 |
|
- |
| Clause 5.10,Table 3, ,Sl No v)(Salmonella sp.) |
- |
1000 |
|
- |
| Clause 5.10,Table 3, ,Sl No iv)(yeast and mould count) |
- |
1000 |
|
- |
| Clause 5.7 and 5.10, Table 2 ,Sl No i)(Moisture) |
- |
500 |
|
- |
| Clause 5.7 and 5.10, Table 2 ,Sl No ii)(a) Total protein, including milk fat b) Milk fat) |
- |
500 |
|
- |
| Clause 5.7 and 5.10, Table 2 ,Sl No iii)(Fat, a) Total fat, including milk fat (for type II)) |
- |
500 |
|
- |
| Clause 5.7 and 5.10, Table 2 ,Sl No iii)(b) Milk fat) |
- |
500 |
|
- |
| Clause 5.7 and 5.10, Table 2 ,Sl No vi)(Total ash) |
- |
500 |
|
- |
| Clause 5.7 and 5.10, Table 2 ,Sl No vii)(Acid insoluble ash) |
- |
500 |
|
- |
| Clause 5.7 and 5.10, Table 2 ,Sl No viii)(Solubility index) |
- |
500 |
|
- |
| Clause 5.7 and 5.10, Table 2 ,Sl No ix)(Vitamin A (as retinol equivalent, RE)) |
- |
1000 |
|
- |
| Clause 5.7 and 5.10, Table 2 ,Sl No xxiii)(Iron) |
- |
1000 |
|
- |
| Clause 5.12, Table 4 ,Sl No i)(Lead) |
- |
1000 |
|
- |
| Clause 5.12, Table 4, Table 2 ,Sl No ii)(Arsenic) |
- |
1000 |
|
- |
| Clause 5.12, Table 4, Table 2 ,Sl No iii)(Tin) |
- |
1000 |
|
- |
| Clause 5.12, Table 4, Table 2 ,Sl No iv)(Cadmium) |
- |
1000 |
|
- |
| Clause 5.7 and 5.10, Table 2 ,Sl No x)(Vitamin D) |
- |
1000 |
|
- |
| Clause 5.7 and 5.10, Table 2 ,Sl No xiv)(Thiamine) |
- |
1000 |
|
- |
| Clause 5.7 and 5.10, Table 2 ,Sl No xvi)(Niacin equivalent) |
- |
1000 |
|
- |
| Clause 5.7 and 5.10, Table 2 ,Sl No xv)(Riboflavin) |
- |
1000 |
|
- |
| Clause 5.7 and 5.10, Table 2 ,Sl No xvii)(Vitamin B6) |
- |
1000 |
|
- |
| Clause 5.7 and 5.10, Table 2 ,Sl No xx)(Vitamin B12) |
- |
1000 |
|
- |
| Clause 5.7 and 5.10, Table 2 ,Sl No xviii)(Dietary folate equivalent (DFE)) |
- |
1000 |
|
- |
| Clause 5.7 and 5.10, Table 2 ,Sl No xix)(Pantothenic acid) |
- |
1000 |
|
- |
| Clause 5.7 and 5.10, Table 2 ,Sl No xxi)(Biotin) |
- |
1000 |
|
- |
| Clause 5.7 and 5.10, Table 2 ,Sl No xiii)(Vitamin C) |
- |
500 |
|
- |
| Clause 5.7 and 5.10, Table 2 ,Sl No xii)(Vitamin K) |
- |
1000 |
|
- |
| Clause 5.7 and 5.10, Table 2 ,Sl No xxvii)(Calcium) |
- |
1000 |
|
- |
| Clause 5.7 and 5.10, Table 2 ,Sl No xxviii)(Phosphorous) |
- |
1000 |
|
- |
| Clause 5.7 and 5.10, Table 2 ,Sl No xxxi)(Iodine) |
- |
500 |
|
- |
| Clause 5.7 and 5.10, Table 2 ,Sl No xxxii)(Copper) |
- |
1000 |
|
- |
| Clause 5.7 and 5.10, Table 2 ,Sl No xxxiv)(Manganese) |
- |
1000 |
|
- |
| Clause 5.7 and 5.10, Table 2 ,Sl No xxxiii)(Zinc) |
- |
1000 |
|
- |
| Clause 5.7 and 5.10, Table 2 ,Sl No xxiv)(Sodium) |
- |
1000 |
|
- |
| Clause 5.7 and 5.10, Table 2 ,Sl No xxv)(Potassium) |
- |
1000 |
|
- |
| Clause 5.7 and 5.10, Table 2 ,Sl No xxvi)(Chloride) |
- |
1000 |
|
- |
| Clause 5.7 and 5.10, Table 2 ,Sl No xxx)(Magnesium) |
- |
1000 |
|
- |
| Clause 5.7 and 5.10, Table 2 ,Sl No xxii)(Choline) |
- |
2000 |
|
- |
| Clause 5.7 and 5.10, Table 2 ,Sl No xxxv)(Selenium) |
- |
1000 |
|
- |
| 5.1(Description) |
- |
0 |
|
- |
| CL 5.2(Scorched particle) |
- |
500 |
|
- |
| Clause 5.7 and 5.10, Table 2 ,Sl No iv)(a) Linoleic acid) |
- |
1000 |
|
- |
| Clause 5.7 and 5.10, Table 2 ,Sl No xi)(Vitamin E (as α-tocopherol equivalent) (only for type II)) |
- |
1000 |
|
- |
| Clause 5.12, Table 4, Table 2 ,Sl No v)(Melamine) |
- |
2000 |
|
- |
| Clause 5.7 and 5.10, Table 2 ,Sl No xxix)(Calcium : Phosphorous ratio) |
- |
1000 |
|
- |
| Clause 5.7,Table 1 ,Sl No xii)(Cholestrol) |
- |
1000 |
|
- |
| Clause 5.7 and 5.10, Table 2 ,Sl No v)(Carbohydrates) |
- |
500 |
|
- |
| Clause 5.7 and 5.10, Table 2 ,Sl No iv)(b) α-Linoleic acid) |
- |
1000 |
|
- |
| Clause 5.7 and 5.10, Table 2 ,Sl No iv)(c) Ratio of linoleic acid and α-Linoleic acid) |
- |
1000 |
|
- |
| Clause 5.10,Table 3, ,Sl No vi)(Listeria monocytogenes) |
- |
1000 |
|
- |
| Clause 5.10,Table 3, ,Sl No vii)(Bacillus cereus) |
- |
1000 |
|
- |
| Clause 5.10,Table 3, ,Sl No viii)(Sulphitr reducing clostridia) |
- |
1000 |
|
- |
| Infant Milk Substitute(Vitamin B12, µg) |
- |
1000 |
|
- |
|
31 Dec, 2026 |
- - |
| 5999 |
CHOKSI LABORATORIES LIMITED, INDORE
| 8136916
| IS 9873 : Part 3 (2017) |
Safety of toys: Part 3 migration of certain elements (Second Revision) |
- |
4000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4.1 - Table 1(Antimony (Sb) - Cl 7,8,9 of IS 9873-3 : 2017 and
ISO 8124-3 : 2010) |
- |
500 |
|
- |
| 4.1 - Table 1(Arsenic (As) - Cl 7,8,9 of IS 9873-3 : 2017 and
ISO 8124-3 : 2010) |
- |
500 |
|
- |
| 4.1 - Table 1(Barium (Ba) - Cl 7,8,9 of IS 9873-3 : 2017 and
ISO 8124-3 : 2010) |
- |
500 |
|
- |
| 4.1 - Table 1(Cadmium (Cd) - Cl 7,8,9 of IS 9873-3 : 2017 and
ISO 8124-3 : 2010) |
- |
500 |
|
- |
| 4.1 - Table 1(Chromium (Cr) - Cl 7,8,9 of IS 9873-3 : 2017 and
ISO 8124-3 : 2010) |
- |
500 |
|
- |
| 4.1 - Table 1(Lead (Pb) - Cl 7,8,9 of IS 9873-3 : 2017 and
ISO 8124-3 : 2010) |
- |
500 |
|
- |
| 4.1 - Table 1(Mercury (Hg) - Cl 7,8,9 of IS 9873-3 : 2017 and
ISO 8124-3 : 2010) |
- |
500 |
|
- |
| 4.1 - Table 1(Selenium (Se) - Cl 7,8,9 of IS 9873-3 : 2017 and
ISO 8124-3 : 2010) |
- |
500 |
|
- |
|
31 Dec, 2026 |
- - |
| 6000 |
CHOKSI LABORATORIES LIMITED, INDORE
| 8136916
| IS 6444 (2023) |
Sulphur Dusting Powders - Specification second revision |
- |
2100 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 2.2 Table 1(Sulphur Content, NV upto 9) |
- |
1500 |
|
- |
| 2.2 Table 1(Sulphur Content, NV Above 9 below 50) |
- |
1500 |
|
- |
| 2.2 Table 1(Sulphur Content, NV above 50) |
- |
1500 |
|
- |
| 2.2 Table 1(Material passing through 75 micron sieve) |
- |
300 |
|
- |
| 2.2 Table 1(Bulk Density after compacting) |
- |
300 |
|
- |
| 2.1(Description) |
- |
0 |
|
- |
| 3.2.1 & 3.2 Table 1 (i)(Sulphr Content - IS 6444:2023) |
- |
1500 |
|
- |
| 3.2 Table 1 (ii)(Material passing through 75 micron IS Sieve - IS 6940:1982) |
- |
300 |
|
300 |
| 3.2 Table 1 (iii)(Bulk Density after compacting - IS 6940:1982) |
- |
300 |
|
- |
| 3.1(Description - IS 6444:2023) |
- |
0 |
|
- |
|
31 Dec, 2026 |
- - |