| 6241 |
Alpha Test House Private Limited, Delhi
| 8131026
| IS 302 : Part 2 : Sec 15 (2009) |
Safety of household and similar electrical appliances: Part 2 particular requirements: Sec 15 appliances for heating liquids (First Revision) |
- |
14500 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 6.0(Classification) |
- |
250 |
|
- |
| 7(Marking and instructions) |
- |
250 |
|
- |
| 8(Protection against live parts) |
- |
500 |
|
- |
| 9(STARTING OF MOTOR-OPERATED APPLIANCES) |
- |
0 |
|
- |
| 10(POWER INPUT AND CURRENT) |
- |
1000 |
|
- |
| 11(HEATING) |
- |
1000 |
|
- |
| 13(LEAKAGE CURRENT AND ELECTRIC STRENGTH AT OPERATING TEMPERATURE) |
- |
1000 |
|
- |
| 14(TRANSIENT OVERVOLTAGES) |
- |
1000 |
|
- |
| 15(MOISTURE RESISTANCE) |
- |
1000 |
|
- |
| 16(LEAKAGE CURRENT AND ELECTRIC STRENGTH) |
- |
1000 |
|
- |
| 17(OVERLOAD PROTECTION OF TRANSFORMERS AND ASSOCIATED CIRCUITS) |
- |
500 |
|
- |
| 18(ENDURANCE) |
- |
0 |
|
- |
| 19(ABNORMAL OPERATION) |
- |
1000 |
|
- |
| 20(STABILITY AND MECHANICAL HAZARDS) |
- |
500 |
|
- |
| 21(MECHANICAL STRENGTH) |
- |
500 |
|
- |
| 22(CONSTRUCTION) |
- |
500 |
|
- |
| 23(INTERNAL WIRING) |
- |
500 |
|
- |
| 24(COMPONENTS) |
- |
500 |
|
- |
| 25(SUPPLY CONNECTION AND EXTERNAL FLEXIBLE CORDS) |
- |
500 |
|
- |
| 26(TERMINALS FOR EXTERNAL CONDUCTORS) |
- |
500 |
|
- |
| 27(PROVISION FOR EARTHING) |
- |
500 |
|
- |
| 28(SCREWS AND CONNECTIONS) |
- |
500 |
|
- |
| 29(CLEARANCES, CREEPAGE DISTANCES AND SOLID INSULATION) |
- |
500 |
|
- |
| 30(RESISTANCE TO HEAT AND FIRE) |
- |
500 |
|
- |
| 31(RESISTANCE TO RUSTING) |
- |
500 |
|
- |
| 32(RADIATION, TOXICITY AND SIMILAR HAZARDS) |
- |
0 |
|
- |
| 22.16(Automatic cord reel) |
- |
0 |
|
- |
| 22.32(Oxygen bomb for rubber material) |
- |
0 |
|
- |
| 22.47(Water pressure inlet) |
- |
0 |
|
- |
| 22.106(Interlocks) |
- |
0 |
|
- |
| 22.3(Flexing test) |
- |
0 |
|
- |
| 24(Components) |
- |
0 |
|
- |
| 19.11.4.1(Electrostatic discharges) |
- |
0 |
|
- |
| 19.11.4.2(Radiated fields) |
- |
0 |
|
- |
| 19.11.4.3(Fast transient bursts) |
- |
0 |
|
- |
| 19.11.4.4(Surge immunity test) |
- |
0 |
|
- |
| 19.11.4.6(Class 3 Voltage dips and interruptions) |
- |
0 |
|
- |
| 19.11.4.7(Harmonics) |
- |
0 |
|
- |
| 4(General requirements) |
- |
0 |
|
- |
| 5(General Conditions of tests) |
- |
0 |
|
- |
| 19.11.4.5(Immunity to conducted discharges) |
- |
0 |
|
- |
| 6(Classification- IS 302-1) |
- |
0 |
|
- |
| 6(Classification- IS 302-1) |
- |
0 |
|
- |
| 7.1(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.1(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.1(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.1(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.1(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.1(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.1(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.1(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.1(Marking- IS 302-2-15) |
- |
0 |
|
- |
| 7.3(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.4(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.5(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.6(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.7(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.8(Marking- IS 302-1) |
- |
0 |
|
- |
| 6(Classification- IS 302-1) |
- |
0 |
|
- |
| 6(Classification- IS 302-1) |
- |
0 |
|
- |
| 7.1(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.1(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.1(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.1(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.1(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.1(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.1(Marking- IS 302-1) |
- |
0 |
|
- |
| Marking- IS 302-1(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.1(Marking- IS 302-2-15) |
- |
0 |
|
- |
| 7.3(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.4(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.5(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.6(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.7(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.8(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.9(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.1O(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.11(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.12(Marking- IS 302-2-15) |
- |
0 |
|
- |
| 7.12(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.12.1(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.12.3(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.12.5(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.12.6(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.13(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.14(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.15(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.101(Marking- IS 302-2-15) |
- |
0 |
|
- |
| 8(Protection Against Electric Shock, IS 302-1) |
- |
0 |
|
- |
| 10(Power Input and Current, IS 302-1) |
- |
0 |
|
- |
| 11(Heating, IS 302-1) |
- |
0 |
|
- |
| 11(Heating, IS 302-1) |
- |
0 |
|
- |
| 11(Heating, IS 302-1) |
- |
0 |
|
- |
| 11(Heating, IS 302-1) |
- |
0 |
|
- |
| 13(Electrical Insulation and Leakage Current at Operating Temperature: Leakage current, IS 302-1) |
- |
0 |
|
- |
| 13(Electrical Insulation and Leakage Current at Operating Temperature: High Voltage, IS 302-1) |
- |
0 |
|
- |
| 15.1(Moisture Resistance, IS 302-1) |
- |
0 |
|
- |
| 15.2(Spillage test as 15.2, IS 3.02-1 & 302-2-15) |
- |
0 |
|
- |
| 16(Leakage current as per Cl 16, IS 302-1) |
- |
0 |
|
- |
| 16(electric strength as per Cl 16, IS 302-1) |
- |
0 |
|
- |
| 17(Overload protection of Transformers and Associated Circuits, IS 302-1) |
- |
0 |
|
- |
| 19.13(Abnormal Operation as per Cl 19, IS 302-2-15) |
- |
0 |
|
- |
| 19.13(Abnormal Operation as per Cl 19, IS 302-1) |
- |
0 |
|
- |
| 19.13(Abnormal Operation as per Cl 19, IS 302-1) |
- |
0 |
|
- |
| 19.13(Abnormal Operation as per Cl 19, IS 302-1) |
- |
0 |
|
- |
| 20.1(Stability & Mechanical Hazards, IS 302-1) |
- |
0 |
|
- |
| 21.1(Mechanical Strength, IS 302-1) |
- |
0 |
|
- |
| 21.2(Mechanical Strength, IS 302-1) |
- |
0 |
|
- |
| 22.1(Construction, IS 302-1) |
- |
0 |
|
- |
| 22.7(Construction as per Cl 22.7, IS 3.02-2-15) |
- |
0 |
|
- |
| 22.107(Construction as per Cl 22.7, IS 3.02-2-15) |
- |
0 |
|
- |
| 22.108(Construction as per Cl 22.8, IS 3.02-2-15) |
- |
0 |
|
- |
| 23.1(Internal Wiring, IS 302-1) |
- |
0 |
|
- |
| 23.2(Internal Wiring, IS 302-1) |
- |
0 |
|
- |
| 23.4(Internal Wiring, IS 302-1) |
- |
0 |
|
- |
| 23.5(Internal Wiring, IS 302-1) |
- |
0 |
|
- |
| 23.6(Internal Wiring, IS 302-1) |
- |
0 |
|
- |
| 23.7(Internal Wiring, IS 302-1) |
- |
0 |
|
- |
| 23.8(Internal Wiring, IS 302-1) |
- |
0 |
|
- |
| 23.9(Internal Wiring, IS 302-1) |
- |
0 |
|
- |
| 23.1O(Internal Wiring, IS 302-1) |
- |
0 |
|
- |
| 25.1(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
- |
| 25.2(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
- |
| 25.5(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
- |
| 25.6(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
- |
| 25.8(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
- |
| 25.9(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
- |
| 25.1(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
- |
| 25.11(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
- |
| 25.12(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
- |
| 25.13(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
- |
| 25.14(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
- |
| 25.14(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
- |
| 25.15(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
- |
| 25.16(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
- |
| 25.17(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
- |
| 25.18(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
- |
| 25.19(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
- |
| 25.2(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
- |
| 25.21(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
- |
| 25.22(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
- |
| 26(Terminals for External Conductors, IS 302-1) |
- |
0 |
|
- |
| 27.1(Provision for Earthing, IS 302-1) |
- |
0 |
|
- |
| 27.2(Provision for Earthing, IS 302-1) |
- |
0 |
|
- |
| 27.3(Provision for Earthing, IS 302-1) |
- |
0 |
|
- |
| 27.4(Provision for Earthing, IS 302-1) |
- |
0 |
|
- |
| 27.5(Provision for Earthing, IS 302-1) |
- |
0 |
|
- |
| 28(Screws & Connections, IS 302-1) |
- |
0 |
|
- |
| 29.1(Clearances, Creepage distances and Solid Insulation, IS 302-1) |
- |
0 |
|
- |
| 29.2(Clearances, Creepage distances and Solid Insulation, IS 302-1) |
- |
0 |
|
- |
| 30.1(Resistance to Heat and Fire, IS 302-1) |
- |
0 |
|
- |
| 30.2(Resistance to Heat and Fire, IS 302-1) |
- |
0 |
|
- |
| 31(Resistance of Rusting, IS 302-1) |
- |
0 |
|
- |
|
- |
- Included w.e.f 30.06.2025
Exclusion: Cl 19 (ABNORMAL OPERATION), Cl 24 (COMPONENTS) |
| 6242 |
Sleen India Biz venture Private Limited, Agra
| 9139736
| IS 1341 (2018) |
Steel Butt Hinges - Specification (Sixth Revision) |
All Type/Size |
8200 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 3 Tables 2 to 9(Types) |
- |
200 |
|
- |
| 5.1 Tables 2 to 9 (2)(Size of Hinge) |
- |
200 |
|
- |
| 5.1 Tables 2 to 9 (3)(Length A) |
- |
200 |
|
- |
| 5.1 Tables 2 to 9 (4)(Breadth B) |
- |
200 |
|
- |
| 5.1 Tables 2 to 9 (4)(Breadth B1) |
- |
200 |
|
- |
| 5.1 Tables 2 to 9 (4)(Breadth B2) |
- |
200 |
|
- |
| 5.1 Tables 2 to 9 (5)(Thickness of Flap C) |
- |
200 |
|
- |
| 5.1 Tables 2 to 9 (6)(Diameter of Hinge Pin D) |
- |
200 |
|
- |
| 5.1 Tables 2 to 9 (7)(Number of Knuckles) |
- |
200 |
|
- |
| 5.1 Tables 2 to 9 (8)(Number of Screw Holes) |
- |
200 |
|
- |
| 5.1 Tables 2 to 9 (9)(Holes for Screw No.) |
- |
200 |
|
- |
| 6.1(General) |
- |
200 |
|
- |
| 6.1(General) |
- |
200 |
|
- |
| 6.1(General) |
- |
200 |
|
- |
| 6.2.1(Knuckles) |
- |
200 |
|
- |
| 6.3(Pins) |
- |
200 |
|
- |
| 6.4(Screw Holes) |
- |
200 |
|
- |
| 6.4.2(Position of Holes) |
- |
200 |
|
- |
| 6.4.2(X) |
- |
200 |
|
- |
| 6.4.2(Y) |
- |
200 |
|
- |
| 6.4.2(Z) |
- |
200 |
|
- |
| 6.4.2.1(Position of Holes) |
- |
200 |
|
- |
| 7(Finish) |
- |
200 |
|
- |
| TABLE-1 (Clause-4)(TITANIUM) |
- |
400 |
|
- |
| TABLE-1 (Clause-4)(VANADIUM) |
- |
400 |
|
- |
| TABLE-1 (Clause-4)(NIOBIUM) |
- |
400 |
|
- |
| TABLE-1 (Clause-4)(Molybdenum) |
- |
400 |
|
- |
| TABLE-1 (Clause-4)(Chromium) |
- |
400 |
|
- |
| TABLE-1 (Clause-4)(Nickel) |
- |
400 |
|
- |
| TABLE-1 (Clause-4)( ALUMINIUM) |
- |
400 |
|
- |
| TABLE-1 (Clause-4)(SILICON) |
- |
400 |
|
- |
| TABLE-1 (Clause-4)(NITROGEN) |
- |
1000 |
|
- |
| TABLE-1 (Clause-4)(MANGANESE) |
- |
400 |
|
- |
| TABLE-1 (Clause-4)(PHOSPHURS) |
- |
400 |
|
- |
| TABLE-1 (Clause-4)(SULPHUR) |
- |
400 |
|
- |
| TABLE-1 (Clause-4)( CARBON) |
- |
400 |
|
- |
| Clause 4 Table 1(Manganese ( Pin)) |
- |
400 |
|
- |
| Clause 4 Table 1(Phosphorus ( Pin)) |
- |
400 |
|
- |
| Clause 4 Table 1(Sulphur ( Pin)) |
- |
400 |
|
- |
| Clause 4 Table 1(Carbon ( Pin)) |
- |
400 |
|
- |
| Clause 4 Table 1(Nitrogen ( Flap)) |
- |
1000 |
|
- |
| Clause 4 Table 1(Manganese ( Flap)) |
- |
400 |
|
- |
| Clause 4 Table 1(Phosphorus ( Flap)) |
- |
400 |
|
- |
| Clause 4 Table 1(Sulphur ( Flap)) |
- |
400 |
|
- |
| Clause 4 Table 1(Carbon ( Flap)) |
- |
400 |
|
- |
| 8(Marking) |
- |
200 |
|
- |
| Cl 4 & Table 1(Sulphur- IS 228(Part 9)) |
- |
400 |
|
- |
| Cl 4 & Table 1(Carbon- IS 228(Part 1)) |
- |
400 |
|
- |
| Cl 4 & Table 1(Phosphorous- IS 228(Part 3)) |
- |
400 |
|
- |
| Cl 4 & Table 1(Manganese- IS 228(Part 2)) |
- |
400 |
|
- |
| Cl 4 & Table 1(Silicon- IS 228(Part 2)) |
- |
400 |
|
- |
| Cl 4 & Table 1(Nitrogen -IS 228(Part 19)) |
- |
1000 |
|
- |
|
- |
- Included w.e.f 08.05.2025 |
| 6243 |
Ace Test Labs & Metrology Pvt. Ltd., Sonipat
| 9162826
| IS 302 : Part 2 : Sec 11 (1994) |
Safety of household and similar electrical appliances: Part 2 particular requirements: Sec 11 tumbler dryers |
- |
22000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 3(GENERAL REQUIREMENT) |
- |
1000 |
|
- |
| 4(GENERAL NOTES ON TESTS) |
- |
1000 |
|
- |
| 5(RATING) |
- |
1000 |
|
- |
| 6(CLASSIFICATION) |
- |
1000 |
|
- |
| 7(MARKING) |
- |
1000 |
|
- |
| 8(PROTECTION AGAINST ELECTRIC SHOCK) |
- |
2000 |
|
- |
| 9(STARTING OF MOTOR-OPERATED APPLIANCES) |
- |
4000 |
|
- |
| 10(INPUT AND CURRENT) |
- |
2000 |
|
- |
| 11(HEATING) |
- |
5000 |
|
- |
| 12(OPERATION TJNDER OVERLOAD CONDITIONS
OF APPLIANCES WITH HEATING ELEMENTS) |
- |
1000 |
|
- |
| 13(ELECTRICAL INSULATION AND LEAKAGE CURRENT AT
OPERATING TEMPERATURE) |
- |
1000 |
|
- |
| 14(RADIO AND TELEVISION INTERFERENCE SUPPRESSION) |
- |
1000 |
|
- |
| 15(MOISTURE RESISTANCE) |
- |
5000 |
|
- |
| 16(INSULATION RESISTANCE AND ELECTRIC STRENGTH) |
- |
2000 |
|
- |
| 17(OVERLOAD PROTECTION) |
- |
2000 |
|
- |
| 18(ENDURANCE ) |
- |
4000 |
|
- |
| 19(ABNORMAL OPERATION) |
- |
5000 |
|
- |
| 20(STABILITY AND MECHANICAL HAZARDS) |
- |
2000 |
|
- |
| 21(MECHANICAL STRENGTH) |
- |
2000 |
|
- |
| 22(CONSTRUCTION) |
- |
2000 |
|
- |
| 23(INTERNAL WIRING) |
- |
1000 |
|
- |
| 24(COMPONENTS) |
- |
2000 |
|
- |
| 25(SUPPLY CONNECTION AND EXTERNAL FLEXIBLE CABLES AND CORDS) |
- |
2000 |
|
- |
| 26(TERMINALS FOR EXTERNAL CONDUCTORS) |
- |
2000 |
|
- |
| 27(PROVISION FOR EARTHING) |
- |
2000 |
|
- |
| 28(SCREWS AND CONNECTIONS) |
- |
1000 |
|
- |
| 29(CREEPAGE DISTANCES, CLEARANCES AND DISTANCES THROUGH INSULATION) |
- |
4000 |
|
- |
| 30(RESISTANCE TO HEAT, FIRE AND TACKING) |
- |
2000 |
|
- |
| 31(RESISTANCE TO RUSTING) |
- |
3000 |
|
- |
| 32(RADIATION, TOXICITY AND SIMILAR HAZARDS) |
- |
4000 |
|
- |
| 101.1(Type Tests) |
- |
22000 |
|
- |
| 101.2(Acceptance Tests) |
- |
22000 |
|
- |
| 101.3(Routine Tests) |
- |
10000 |
|
- |
| 3(GENERAL REQUIREMENT) |
- |
1000 |
|
- |
| 4(GENERAL NOTES ON TESTS) |
- |
4000 |
|
- |
| 5(RATING) |
- |
2000 |
|
- |
| 6(CLASSIFICATION) |
- |
2000 |
|
- |
| 7(MARKING) |
- |
2000 |
|
- |
| 8(PROTECTION AGAINST ELECTRIC SHOCK) |
- |
4000 |
|
- |
| 9(STARTING OF MOTOR-OPERATED APPLIANCES) |
- |
3000 |
|
- |
| 10(INPUT AND CURRENT) |
- |
4000 |
|
- |
| 11(HEATING) |
- |
12000 |
|
- |
| 12(OPERATION TJNDER OVERLOAD CONDITIONS
OF APPLIANCES WITH HEATING ELEMENTS) |
- |
4000 |
|
- |
| 13(ELECTRICAL INSULATION AND LEAKAGE CURRENT AT
OPERATING TEMPERATURE) |
- |
2000 |
|
- |
| 14(RADIO AND TELEVISION INTERFERENCE SUPPRESSION) |
- |
3000 |
|
- |
| 15(MOISTURE RESISTANCE) |
- |
5000 |
|
- |
| 16(INSULATION RESISTANCE AND ELECTRIC STRENGTH) |
- |
5000 |
|
- |
| 17(OVERLOAD PROTECTION) |
- |
5000 |
|
- |
| 18(ENDURANCE ) |
- |
5000 |
|
- |
| 19(ABNORMAL OPERATION) |
- |
4000 |
|
- |
| 20(STABILITY AND MECHANICAL HAZARDS) |
- |
4000 |
|
- |
| 21(MECHANICAL STRENGTH) |
- |
4000 |
|
- |
| 22(CONSTRUCTION) |
- |
4000 |
|
- |
| 23(INTERNAL WIRING) |
- |
4000 |
|
- |
| 24(COMPONENTS) |
- |
4000 |
|
- |
| 25(SUPPLY CONNECTION AND EXTERNAL FLEXIBLE CABLES AND CORDS) |
- |
5000 |
|
- |
| 26(TERMINALS FOR EXTERNAL CONDUCTORS) |
- |
5000 |
|
- |
| 27(PROVISION FOR EARTHING) |
- |
5000 |
|
- |
| 28(SCREWS AND CONNECTIONS) |
- |
5000 |
|
- |
| 29(CREEPAGE DISTANCES, CLEARANCES AND DISTANCES THROUGH INSULATION) |
- |
6000 |
|
- |
| 30(RESISTANCE TO HEAT, FIRE AND TACKING) |
- |
8000 |
|
- |
| 31(RESISTANCE TO RUSTING) |
- |
8000 |
|
- |
| 32(RADIATION, TOXICITY AND SIMILAR HAZARDS) |
- |
10000 |
|
- |
| 101.1(Type Tests) |
- |
12000 |
|
- |
| 101.2(Acceptance Tests) |
- |
22000 |
|
- |
| 101.3(Routine Tests) |
- |
2500 |
|
- |
|
14 Nov, 2027 |
- Included w.e.f 04.07.2025
Exclusion: Cl 19.11.4.1-19.11.4.7(EMI/EMC) |
| 6244 |
DELHI TEST HOUSE (50) KUNDLI SONIPAT
| 9127026
| IS 12933 : Part 2 (2003) |
Solar flat plate collector - Specification: Part 2 components (Second Revision) |
-- |
4000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 12.1.1(Thermal Shock Test) |
- |
500 |
|
- |
| 11(MATERIALS) |
- |
200 |
|
- |
| 10(BACK AND SIDE INSULATION) |
- |
500 |
|
- |
| 9.2.2(Bonding Between Riser and Sheet) |
- |
500 |
|
- |
| 9.2.1(Static Pressure Leakage Test) |
- |
500 |
|
- |
| 9.1.4(Temperature Test) |
- |
500 |
|
- |
| 8(FABRICATION) |
- |
300 |
|
- |
| 7(WORKMANSHIP AND FINISH) |
- |
500 |
|
- |
| 5.1(Transmittance Test) |
- |
500 |
|
- |
| 12.1.1(Thermal Shock Test) |
- |
500 |
|
- |
| 11(MATERIALS) |
- |
200 |
|
- |
| 10(BACK AND SIDE INSULATION) |
- |
500 |
|
- |
| 9.2.2(Bonding Between Riser and Sheet) |
- |
500 |
|
- |
| 9.2.1(Static Pressure Leakage Test) |
- |
500 |
|
- |
| 9.1.4(Temperature Test) |
- |
500 |
|
- |
| 8(FABRICATION) |
- |
300 |
|
- |
| 7(WORKMANSHIP AND FINISH) |
- |
500 |
|
- |
| 5.1(Transmittance Test) |
- |
500 |
|
- |
|
23 Jun, 2028 |
- Included w.e.f.31.07.2025 |
| 6245 |
Sleen India Biz venture Private Limited, Agra
| 9139736
| IS 12817 (2020) |
Stainless Steel Butt Hinges - Specification ( Third Revision ) |
All Size/Type |
14800 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 6.2, Table 1 to 6(Length , A -IS 12817) |
- |
200 |
|
- |
| 6.2, Table 1 to 6(Breadth, B-IS 12817) |
- |
200 |
|
- |
| 6.2, Table 1 to 6(Breadth, B1-IS 12817) |
- |
0 |
|
Test price for breadth measurement is 200/-. |
| 6.2, Table 1 to 6(Breadth, B2-IS 12817) |
- |
0 |
|
Test price for breadth measurement is 200/-. |
| 6.2, Table 1 to 6(Thickness of flap, C-IS 12817) |
- |
200 |
|
- |
| 6.2, Table 1 to 6(Dia. of Hinge pin, D-IS 12817 ) |
- |
200 |
|
- |
| 6.2, Table 1 to 6(Number of Knuckles- IS 12817 ) |
- |
100 |
|
- |
| 6.2, Table 1 to 6(Number of Screw Holes -IS 12817 ) |
- |
100 |
|
- |
| 6.2, Table 1 to 6(Holes for Screw Number- IS 12817 ) |
- |
100 |
|
- |
| 7.1(General - IS 12817 ) |
- |
100 |
|
- |
| 7.2(Knuckles - IS 12817 ) |
- |
200 |
|
- |
| 7.3(Pins- IS 12817 ) |
- |
200 |
|
- |
| 7.4(Screw Holes- IS 12817 ) |
- |
200 |
|
- |
| 7.4.2(Position of screw holes - IS 12817 ) |
- |
200 |
|
- |
| 7.4.2, Fig 1(The distance of the screw holes from the end of the flap - IS 12817 ) |
- |
200 |
|
- |
| 8.0(Finish - IS 12817 ) |
- |
100 |
|
- |
| Clause 4.1.2(Silicon (Pin) ) |
- |
300 |
|
- |
| Clause 4.1.2(Phosphorus (Pin) ) |
- |
300 |
|
- |
| Clause 4.1.2(Sulphur (Pin) ) |
- |
300 |
|
- |
| Clause 4.1.2(Manganese (Pin) ) |
- |
300 |
|
- |
| Clause 4.1.2(Carbon (Pin) ) |
- |
300 |
|
- |
| Clause 4.1.1(Silicon (Flap) ) |
- |
300 |
|
- |
| Clause 4.1.1(Phosphorus (Flap) ) |
- |
300 |
|
- |
| Clause 4.1.1(Sulphur (Flap) ) |
- |
300 |
|
- |
| Clause 4.1.1(Manganese (Flap) ) |
- |
300 |
|
- |
| Clause 4.1.1(Carbon (Flap) ) |
- |
300 |
|
- |
| Clause 7.4.2 (Dimension - Z ) |
- |
200 |
|
- |
| Clause 7.4.2 (Dimension - Y ) |
- |
200 |
|
- |
| Clause 7.4.2 (Dimension - X ) |
- |
200 |
|
- |
| Clause 7.4.1(Number of holes) |
- |
100 |
|
- |
| As per Cl.4(Carbon) |
- |
300 |
|
- |
| As per Cl.4(Sulphur) |
- |
300 |
|
- |
| As per Cl.4(Phosphorus) |
- |
300 |
|
- |
| As per Cl.4(Manganese) |
- |
300 |
|
- |
| As per Cl.4(Nitrogen) |
- |
2000 |
|
- |
| As per Cl.4(Silicon) |
- |
300 |
|
- |
| As per Cl.4(Aluminium) |
- |
300 |
|
- |
| As per Cl.4(Chromium) |
- |
300 |
|
- |
| As per Cl.4(Vanadium) |
- |
300 |
|
- |
| As per Cl.4(Molybdenum) |
- |
300 |
|
- |
| As per Cl.4(Niobium) |
- |
300 |
|
- |
| As per Cl.4(Nickel) |
- |
300 |
|
- |
| As per Cl.4(Copper) |
- |
300 |
|
- |
| As per Cl.4(Titanium) |
- |
300 |
|
- |
| As per Cl.4(Zirconium) |
- |
300 |
|
- |
| As per Cl.4(Tungsten) |
- |
300 |
|
- |
| As per Cl.4(Cerium) |
- |
300 |
|
- |
|
- |
- Included w.e.f 10.07.2025 |
| 6246 |
QA TESTING LABORATORIES PRIVATE LIMITED, NOIDA
| 8169906
| IS 1161 (2014) |
Steel tubes for structural purposes - Specification (Fifth Revision) |
Y St 210, Y St 240, Y St 310 , Y St 355 |
5200 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Clause - 5.1, Table-3( CARBON) |
- |
500 |
|
Testing facility available |
| Clause - 5.1, Table-3(MANGANESE) |
- |
500 |
|
Testing facility available |
| Clause - 5.1, Table-3(SULPHUR) |
- |
500 |
|
Testing facility available |
| Clause - 5.1, Table-3(PHOSPHURS) |
- |
500 |
|
Testing facility available |
| Cl 11.3.1(Cold bend test (upto & including 50 mm NB)) |
- |
500 |
|
Testing facility available |
| 3.1 & 6.1, 6.1.1 & 6.1.3 , Table 1(Outer Diameter - SOP MT-23) |
- |
500 |
|
Testing facility available |
| 3.1 & 6.1, 6.1.1 & 6.1.3 , Table 1(Thickness - SOP MT-23) |
- |
500 |
|
Testing facility available |
| 3.1 & 6.1, 6.1.1 & 6.1.3 , Table 1(Mass - SOP MT-23) |
- |
500 |
|
Testing facility available |
| Cl. 11.2 Table 2(Yield strength) |
- |
600 |
|
Testing facility available |
| Cl. 11.2 Table 2(Elongation) |
- |
600 |
|
Testing facility available |
| Cl 11.3.1(Cold bend test (upto & including 50 mm NB)) |
- |
500 |
|
- |
| 3.1 & 6.1, 6.1.1 & 6.1.3 , Table 1(Outer Diameter - SOP MT-23) |
- |
500 |
|
- |
| 3.1 & 6.1, 6.1.1 & 6.1.3 , Table 1(Thickness - SOP MT-23) |
- |
500 |
|
- |
| 3.1 & 6.1, 6.1.1 & 6.1.3 , Table 1(Mass - SOP MT-23) |
- |
500 |
|
- |
| Cl. 11.2 Table 2(Yield strength) |
- |
500 |
|
- |
| Cl. 11.2 Table 2(Elongation) |
- |
500 |
|
- |
| Cl 11.3.1(Cold bend test (upto & including 50 mm NB)) |
- |
500 |
|
- |
| 3.1 & 6.1, 6.1.1 & 6.1.3 , Table 1(Outer Diameter - SOP MT-23) |
- |
500 |
|
- |
| 3.1 & 6.1, 6.1.1 & 6.1.3 , Table 1(Thickness - SOP MT-23) |
- |
500 |
|
- |
| 3.1 & 6.1, 6.1.1 & 6.1.3 , Table 1(Mass - SOP MT-23) |
- |
500 |
|
- |
| Cl. 11.2 Table 2(Yield strength) |
- |
500 |
|
- |
| Cl. 11.2 Table 2(Elongation) |
- |
500 |
|
- |
|
05 Apr, 2028 |
- Included w.e.f. 18.08.2025 |
| 6247 |
JBS TESTING SOLUTIONS PVT LTD (27), JALANDHAR
| 9164606
| IS 14364 (2024) |
Quaternary Ammonium Compound Based Surface Cleaner, Liquid � Specification ( First Revision ) |
- |
25000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl-4.1(Description) |
- |
25000 |
|
For complete testing |
| Cl-4.2(Composition) |
- |
25000 |
|
For complete testing |
| Cl-4.3(Odour) |
- |
25000 |
|
For complete testing |
| Cl-4.4(Colour) |
- |
25000 |
|
For complete testing |
| Cl-4.5(Stability on Dilution) |
- |
25000 |
|
For complete testing |
| Cl-4.6(Cleaning Property) |
- |
25000 |
|
For complete testing |
| Cl-4.7(Applicability) |
- |
25000 |
|
For complete testing |
| Cl-4.8(Keeping Quality) |
- |
25000 |
|
For complete testing |
| Cl-4.8 & 4.9, Table-1 (i)(Total non-volatile matter, percent by mass, Min) |
- |
25000 |
|
For complete testing |
| Cl-4.8 & 4.9, Table-1 (ii)(pH) |
- |
25000 |
|
For complete testing |
| Cl-4.8 & 4.9, Table-1 (iii)(QAC content, percent by mass, Min) |
- |
25000 |
|
For complete testing |
| Cl-6(Marking) |
- |
25000 |
|
For complete testing |
| Cl-4.1(Description) |
- |
- |
|
- |
| Cl-4.2(Composition) |
- |
- |
|
- |
| Cl-4.3(Odour) |
- |
- |
|
- |
| Cl-4.4(Colour) |
- |
- |
|
- |
| Cl-4.5(Stability on Dilution) |
- |
- |
|
- |
| Cl-4.6(Cleaning Property) |
- |
- |
|
- |
| Cl-4.7(Applicability) |
- |
- |
|
- |
| Cl-4.8(Keeping Quality) |
- |
- |
|
- |
| Cl-4.8 & 4.9, Table-1 (i)(Total non-volatile matter, percent by mass, Min) |
- |
- |
|
- |
| Cl-4.8 & 4.9, Table-1 (ii)(pH) |
- |
- |
|
- |
| Cl-4.8 & 4.9, Table-1 (iii)(QAC content, percent by mass, Min) |
- |
- |
|
- |
| Cl-6(Marking) |
- |
- |
|
- |
|
- |
- Included w.e.f.21.05.2025 |
| 6248 |
ATCC TEST LABS LLP
| 8172626
| IS 1554 : Part 1 (1988) |
Specification for pvc insulated (Heavy Duty) electric cables: Part 1 for working voltages up to and including 1100 v (Third Revision) |
- |
10000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 3.1(MATERIALS : CONDUCTOR) |
- |
500 |
|
Rs. 10000/- for single core sheathed cable, Rs. 1000/- for each additional core, Rs. 3000/- for armoured cable, Rs. 5000/- for Category C1 and Rs.10000/- for Category C2 |
| 4.1.1(INSULATION : General Purjose Insulaiion) |
- |
500 |
|
- |
| 4.1.2(INSULATION : Heat Resisting Insulation) |
- |
500 |
|
- |
| 5.1(MATERIALS : FILLER AND INNER SHEATH) |
- |
500 |
|
- |
| 5.2(MATERIALS : FILLER AND INNER SHEATH) |
- |
500 |
|
- |
| 6.1(MATERIALS : ARMGURING) |
- |
500 |
|
- |
| 6.2(MATERIALS : ARMGURING) |
- |
500 |
|
- |
| 7.1.1(OUTER SHEATH : For Cables with General Purpose InsuIafion) |
- |
500 |
|
- |
| 7.1.2(OUTER SHEATH : For Cables with Heat Resisting InsuIalion) |
- |
500 |
|
- |
| 8.1(CONSTRUCTION : CONDUCTOR) |
- |
500 |
|
- |
| 8.2(CONSTRUCTION : CONDUCTOR) |
- |
500 |
|
- |
| 9.1(INSULATION ) |
- |
500 |
|
- |
| 9.2(INSULATION : Thickness of Insulation) |
- |
1000 |
|
- |
| 9.3(INSULATION :Tolerance on Thickness of Insulation) |
- |
1000 |
|
- |
| 9.4(INSULATION : Application of Insulation) |
- |
500 |
|
- |
| 10.1(CORE IDENTIFICATION) |
- |
500 |
|
- |
| 10.2(CORE IDENTIFICATION) |
- |
500 |
|
- |
| 10.3(CORE IDENTIFICATION) |
- |
500 |
|
- |
| 10.3.1(Arrangement of Marking) |
- |
500 |
|
- |
| 11.1(LAYING UP OF CORES) |
- |
500 |
|
- |
| 11.2(LAYING UP OF CORES) |
- |
500 |
|
- |
| 12.1(INNER SHEATH) |
- |
500 |
|
- |
| 12.2(INNER SHEATH) |
- |
500 |
|
- |
| 12.3(INNER SHEATH :Thickness of Inner Sheath) |
- |
1000 |
|
- |
| 12.3.1(INNER SHEATH :Thickness of Inner Sheath) |
- |
1000 |
|
- |
| 13.1.1(ARMOURING : Application) |
- |
500 |
|
- |
| 13.1.2(Armouring: Coverage ) |
- |
1000 |
|
- |
| 13.1.3(ARMOURING : Direction of lay ) |
- |
500 |
|
- |
| 13.1.4(ARMOURING : Application) |
- |
500 |
|
- |
| 13.2(ARMOURING : Type of Armour) |
- |
500 |
|
- |
| 13.2.1(ARMOURING : Type of Armour) |
- |
500 |
|
- |
| 13.3(Armouring : Dimensions -Wire Diameter) |
- |
1000 |
|
- |
| 13.3(Armouring : Dimensions -Formed wire ) |
- |
1000 |
|
- |
| 13.4(ARMOURING : Joints) |
- |
500 |
|
- |
| 13.5.1(ARMOURING : Resistance) |
- |
1000 |
|
- |
| 13.5.2(ARMOURING : Resistance) |
- |
1000 |
|
- |
| 13.6 a)(ARMOURING: Tensile Strength) |
- |
1000 |
|
- |
| 13.6 b)(ARMOURING: Elongation ) |
- |
1000 |
|
- |
| 13.6 c)(ARMOURING: Torsion Test (For round wire ) ) |
- |
1000 |
|
- |
| 13.6 d)(ARMOURING: Winding Test(For formed wire)) |
- |
1000 |
|
- |
| 13.6 e)(ARMOURING: Uniformity of zinc coating) |
- |
1000 |
|
- |
| 13.6 f)(ARMOURING: Mass of zinc coating ) |
- |
1000 |
|
- |
| 13.6 g)(ARMOURING: Resistivity) |
- |
1000 |
|
- |
| 14.1(OUTER SHEATH) |
- |
500 |
|
- |
| 14.2(OUTER SHEATH) |
- |
500 |
|
- |
| 14.3(OUTER SHEATH : Colour ) |
- |
500 |
|
- |
| 14.4.1(Thickness of Outer Sheath : Unarmowed Cables) |
- |
1000 |
|
- |
| 14.4.2(Thickness of Outer Sheath : Armoured Cables) |
- |
1000 |
|
- |
| 15.1 a) 1)(Tests on conductor : Annealing test ( for copper )) |
- |
1000 |
|
- |
| 15.1 a) 2)(Tensile test (for aluminium) - Before stranding ) |
- |
1000 |
|
- |
| 15.1 a) 3)(Tests on conductor : Wrapping test ( for aluminium )) |
- |
1000 |
|
- |
| 15.1 a) 4)(Tests on conductor : Conductor resistance test) |
- |
1000 |
|
- |
| 15.1 a) 4)(Resistance test - Neutral conductor ) |
- |
1000 |
|
- |
| 15.1 d)1)(Phyaical tests for insulation : Tensile Test) |
- |
1000 |
|
- |
| 15.1 d)1)(Phyaical tests for insulation : Elongation ) |
- |
1000 |
|
- |
| 15.1 d)1)(Physical tests for sheath : Tensile stregth ) |
- |
1000 |
|
- |
| 15.1 d)1)(Physical tests for sheath : Elongation ) |
- |
1000 |
|
- |
| 15.1 d)2)(Phyaical tests for insulation- Ageing in air Oven : Tensile Test) |
- |
2000 |
|
- |
| 15.1 d)2)(Phyaical tests for insulation - Ageing in air oven : Elongation ) |
- |
2000 |
|
- |
| 15.1 d)2)(Phyaical tests for insulation - Ageing in air Oven : Tensile Variation ) |
- |
2000 |
|
- |
| 15.1 d)2)(Phyaical tests for insulation- Ageing in air oven : Elongation Variation ) |
- |
2000 |
|
- |
| 15.1 d)2)(Physical tests for outer sheath- Ageing in air oven : Tensile stregth ) |
- |
2000 |
|
- |
| 15.1 d)2)(Physical tests for outer sheath -Ageing in air oven : Elongation ) |
- |
2000 |
|
- |
| 15.1 d)2)(Physical tests for outer sheath- Ageing in air oven : Tensile stregth Variation ) |
- |
2000 |
|
- |
| 15.1 d)2)(Physical tests for outer sheath -Ageing in air oven : Elongation Variation ) |
- |
2000 |
|
- |
| 15.1 d)3)(Phyaical tests for insulation : Shrinkage ) |
- |
1000 |
|
- |
| 15.1 d)3)(Phyaical tests for insulation : Shrinkage - Crack observed ) |
- |
1000 |
|
- |
| 15.1 d)3)(Phyaical tests for Sheath : Shrinkage ) |
- |
1000 |
|
- |
| 15.1 d)3)(Phyaical tests for Sheath : Shrinkage - Crack observed ) |
- |
1000 |
|
- |
| 15.1 d)4)(Hot deformation : Insulation ) |
- |
1000 |
|
- |
| 15.1 d)4)(Hot deformation : Sheath ) |
- |
1000 |
|
- |
| 15.1 d)5)( Loss of mass in air oven- Insulation ) |
- |
2000 |
|
- |
| 15.1 d)5)( Loss of mass in air oven- sheath ) |
- |
2000 |
|
- |
| 15.1 d)6)(Heat shock test- Insulation ) |
- |
1000 |
|
- |
| 15.1 d)6)(Heat shock test- sheath ) |
- |
1000 |
|
- |
| 15.1 d)7)(Thermal stability- insulation ) |
- |
1000 |
|
- |
| 15.1 d)7)(Thermal stability- Sheath ) |
- |
1000 |
|
- |
| 15.1 e)(Insulation resistance test : Volume Resistivity ) |
- |
1000 |
|
- |
| 15.1 e)(Insulation resistance test : IR Constant ) |
- |
1000 |
|
- |
| 15.1 f)(High voltage test ( water immersion test )) |
- |
2000 |
|
- |
| 15.1 g)(High voltage test at room temperature) |
- |
1000 |
|
- |
| 15.1 g)(High voltage test at room temperature) |
- |
1000 |
|
- |
| 15.4 a)(Cold bend test- Insulation ( Optional test)) |
- |
1000 |
|
- |
| 15.4 a)(Cold bend test- Sheath ( Optional test)) |
- |
1000 |
|
- |
| 15.4 b)(Cold impact test- Insulation ( Optional test)) |
- |
1000 |
|
- |
| 15.4 b)(Cold impact test- Sheath ( Optional test)) |
- |
1000 |
|
- |
| 15.4 c)(Armour resistance test ( for other than mining cables ).- Optional test ) |
- |
1000 |
|
- |
| 16.1(DETAILS OF TESTS : General) |
- |
500 |
|
- |
| 16.2(DETAILS OF TESTS : High Voltage Test at Room Temperature) |
- |
1000 |
|
- |
| 16.3.1(High Voltage Test ( Water Immersion Test ) : a.c. Test) |
- |
2000 |
|
- |
| 16.3.2(High Voltage Test ( Water Immersion Test ) : d.c. Test) |
- |
3000 |
|
- |
| 16.4(Flammability Test) |
- |
1000 |
|
- |
| 16.5(Oxygen Index Test) |
- |
3000 |
|
- |
| 16.6(Flame Retardance Test on Single Cables) |
- |
1000 |
|
- |
| 16.7(Flame Retardance Test on Bunched Cables) |
- |
5000 |
|
- |
| 16.9(Test for Halogen Acid Gas Evolution) |
- |
3000 |
|
- |
| 16.1(Temperature Index) |
- |
3000 |
|
- |
| 17.1(IDENTIFICATION : Manufacturer’s Identification) |
- |
500 |
|
- |
| 17.2(IDENTIFICATION : Cable Identification) |
- |
500 |
|
- |
| 17.2.1(IDENTIFICATION : Cable Identification) |
- |
500 |
|
- |
| 17.3(IDENTIFICATION : Cable Code) |
- |
500 |
|
- |
| 15.1.e(Insulation resistance Test- Insulation resistance At Maximum rated temperature temperature) |
- |
1000 |
|
- |
| 15.1.e(Insulation resistance Test- Insulation resistance constant At Room temperature) |
- |
1000 |
|
- |
| 15.1.e(Insulation resistance Test- Volume Resistivity At Maximum rated temperature temperature) |
- |
1000 |
|
- |
| 15.1.e(Insulation resistance Test- Volume Resistivity At Room temperature) |
- |
1000 |
|
- |
| 16.4(Flammability Test- Un affected portion) |
- |
1000 |
|
- |
| 16.4(Flammability Test- Period of Burning) |
- |
1000 |
|
- |
| 9.3(Minimum Thickness of Reduce core insulation) |
- |
1000 |
|
- |
| 9.2(Thickness of Reduce core insulation) |
- |
1000 |
|
- |
| 3.1 Table 2
IS 8130(Number of wires in the conductor) |
- |
500 |
|
- |
| Cl No. 16.10(Smoke density test) |
- |
2000 |
|
- |
| Cl No. 16.8(Test for specific optical density of smoke) |
- |
3000 |
|
- |
| Table 4(Copper purity test) |
- |
5000 |
|
- |
| Cl.8(Conductor, Number of wires.) |
- |
500 |
|
- |
| Cl.8(Conductor, Number of wires.) |
- |
500 |
|
- |
| Cl.8(Flexibility class) |
- |
1000 |
|
- |
| [(Cl.15), (d), 2](After ageing, Elongation of Sheath [Percentage]) |
- |
2000 |
|
- |
| 15.1 a) 2)(Tensile test (for aluminium) - After stranding ) |
- |
2000 |
|
- |
| Cl No. 16.10(Smoke density test) |
- |
3000 |
|
- |
| Cl No. 16.8(Test for specific optical density of smoke) |
- |
3000 |
|
- |
| Table 4(Copper purity test) |
- |
5000 |
|
- |
| Cl.8(Conductor, Number of wires.) |
- |
500 |
|
- |
| Cl.8(Conductor, Number of wires.) |
- |
500 |
|
- |
| Cl.8(Flexibility class) |
- |
500 |
|
- |
| [(Cl.15), (d), 2](After ageing, Elongation of Sheath [Percentage]) |
- |
2000 |
|
- |
| Cl No. 16.10(Smoke density test) |
- |
3000 |
|
- |
| Cl No. 16.8(Test for specific optical density of smoke) |
- |
3000 |
|
- |
| Table 4(Copper purity test) |
- |
5000 |
|
- |
| Cl.8(Conductor, Number of wires.) |
- |
500 |
|
- |
| Cl.8(Conductor, Number of wires.) |
- |
500 |
|
- |
| Cl.8(Flexibility class) |
- |
500 |
|
- |
| [(Cl.15), (d), 2](After ageing, Elongation of Sheath [Percentage]) |
- |
2000 |
|
- |
| Cl No. 16.10(Smoke density test) |
- |
3000 |
|
- |
| Cl No. 16.8(Test for specific optical density of smoke) |
- |
3000 |
|
- |
| Table 4(Copper purity test) |
- |
5000 |
|
- |
| Cl.8(Conductor, Number of wires.) |
- |
500 |
|
- |
| Cl.8(Conductor, Number of wires.) |
- |
500 |
|
- |
| Cl.8(Flexibility class) |
- |
500 |
|
- |
| [(Cl.15), (d), 2](After ageing, Elongation of Sheath [Percentage]) |
- |
2000 |
|
- |
|
15 Jun, 2029 |
- Included w.e.f.16.07.2025 |
| 6249 |
Sleen India Biz venture Private Limited, Agra
| 9139736
| IS 14715 : Part 2 (2016) |
Jute geotextiles Part 2 Control of bank erosion in rivers and waterways – Specification (second revision) |
All type |
6500 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 1(Thickness at 2 kPa- IS 13162 (Part 3)) |
- |
200 |
|
- |
| 2(Width- IS 1954) |
- |
100 |
|
- |
| 2(Mass- IS 15891 (Part 1)) |
- |
300 |
|
- |
| 2(Thickness at 2 kPa-IS 15891 (Part 2)) |
- |
200 |
|
- |
| 2(Tensile strength MD*CD- IS 15891 (Part 3)) |
- |
1500 |
|
- |
| 1(Width- IS 1954) |
- |
100 |
|
- |
| 1(Ends × Picks- IS 1963) |
- |
200 |
|
- |
| 1(Thickness at 2 kPa- IS 13162 (Part 3)) |
- |
200 |
|
- |
| 1(Tensile strength in MD × CD,- IS 13162 (Part 5)) |
- |
0 |
|
Tensile and elongation test price is 1500/-. |
| 1(Elongation at break in MD × CD- IS 13162 (Part 5)) |
- |
0 |
|
Tensile and elongation test price is 1500/-. |
| 1(Puncture resistance- IS 16078) |
- |
1000 |
|
- |
| 1(Burst strength- IS 1966 (Part 1)) |
- |
1000 |
|
- |
| 1(Permittivity at 50 mm constant head- IS 14324) |
- |
1000 |
|
- |
| 1(Apparent opening size (A. O. S.) , O95- IS 14294) |
- |
500 |
|
- |
| 1(Apparent opening size (A. O. S.) , O95- IS 14294) |
- |
500 |
|
- |
| 4, Table 1, (ii)(Construction) |
- |
200 |
|
- |
| 4, Table 1, (ii)(Weight at 20 percent moisture regain, g/m2 , Min, for Treated Woven Jute Geotextiles) |
- |
300 |
|
- |
| 4, Table 1, (iii)(Width, cm, for Treated Woven Jute Geotextiles) |
- |
0 |
|
Test price for width test is 100/-. |
| 4, Table 1, (iv)(Ends x Picks/dm, for Treated Woven Jute Geotextiles) |
- |
0 |
|
Test price for Ends x picks/dm is 200/-. |
| 4, Table 1, (v)(Thickness at 2kPa, mm, for Treated Woven Jute Geotextiles) |
- |
0 |
|
Test price for thickness measurement is 200/-. |
| 4, Table 1, (vi)(Tensile Strength in MD x CD, kN/m, for Treated Woven Jute Geotextiles) |
- |
0 |
|
Test price for tensile and elongation test is 1500/-. |
| 4, Table 1, (vii)(Elongation at break in MD x CD, percent, for Treated Woven Jute Geotextiles) |
- |
0 |
|
Test price for tensile and elongation test is 1500/-. |
| 4, Table 1, (viii)(Puncture Resistance, kN, Min, for Treated Woven Jute Geotextiles) |
- |
0 |
|
Test price for puncturing test is 1000/-. |
| 4, Table 1, (ix)(Burst Strength, kPa. Min, for Treated Woven Jute Geotextiles) |
- |
0 |
|
Test price for bursting Strength is 1000/-. |
| 4, Table 1, (x)(Permittivity at 50 mm constant head, sec –1 , Min, for Treated Woven Jute Geotextiles) |
- |
0 |
|
Test price for permittivity test is 1000/-. |
| 4, Table 1, (xi)(Apparent opening size (A. O. S.) , O95 , Micron3, for Treated Woven Jute Geotextiles) |
- |
0 |
|
Test price for apparent size is 500/-. |
| 5(Sampling) |
- |
300 |
|
- |
| 6(Packaging) |
- |
200 |
|
- |
| 1(Thickness at 2 kPa- IS 13162 (Part 3)) |
- |
0 |
|
- |
| 2(Width- IS 1954) |
- |
0 |
|
- |
| 2(Mass- IS 15891 (Part 1)) |
- |
0 |
|
- |
| 2(Thickness at 2 kPa-IS 15891 (Part 2)) |
- |
0 |
|
- |
| 2(Tensile strength MD*CD- IS 15891 (Part 3)) |
- |
0 |
|
- |
| 1(Width- IS 1954) |
- |
0 |
|
- |
| 1(Ends × Picks- IS 1963) |
- |
0 |
|
- |
| 1(Thickness at 2 kPa- IS 13162 (Part 3)) |
- |
0 |
|
- |
| 1(Tensile strength in MD × CD,- IS 13162 (Part 5)) |
- |
0 |
|
- |
| 1(Elongation at break in MD × CD- IS 13162 (Part 5)) |
- |
0 |
|
- |
| 1(Puncture resistance- IS 16078) |
- |
0 |
|
- |
| 1(Burst strength- IS 1966 (Part 1)) |
- |
0 |
|
- |
| 1(Permittivity at 50 mm constant head- IS 14324) |
- |
0 |
|
- |
| 1(Apparent opening size (A. O. S.) , O95- IS 14294) |
- |
0 |
|
- |
| 1(Apparent opening size (A. O. S.) , O95- IS 14294) |
- |
0 |
|
- |
| 4, Table 1, (ii)(Construction) |
- |
0 |
|
- |
| 4, Table 1, (ii)(Weight at 20 percent moisture regain, g/m2 , Min, for Treated Woven Jute Geotextiles) |
- |
0 |
|
- |
| 4, Table 1, (iii)(Width, cm, for Treated Woven Jute Geotextiles) |
- |
0 |
|
- |
| 4, Table 1, (iv)(Ends x Picks/dm, for Treated Woven Jute Geotextiles) |
- |
0 |
|
- |
| 4, Table 1, (v)(Thickness at 2kPa, mm, for Treated Woven Jute Geotextiles) |
- |
0 |
|
- |
| 4, Table 1, (vi)(Tensile Strength in MD x CD, kN/m, for Treated Woven Jute Geotextiles) |
- |
0 |
|
- |
| 4, Table 1, (vii)(Elongation at break in MD x CD, percent, for Treated Woven Jute Geotextiles) |
- |
0 |
|
- |
| 4, Table 1, (viii)(Puncture Resistance, kN, Min, for Treated Woven Jute Geotextiles) |
- |
0 |
|
- |
| 4, Table 1, (ix)(Burst Strength, kPa. Min, for Treated Woven Jute Geotextiles) |
- |
0 |
|
- |
| 4, Table 1, (x)(Permittivity at 50 mm constant head, sec –1 , Min, for Treated Woven Jute Geotextiles) |
- |
0 |
|
- |
| 4, Table 1, (xi)(Apparent opening size (A. O. S.) , O95 , Micron3, for Treated Woven Jute Geotextiles) |
- |
0 |
|
- |
| 5(Sampling) |
- |
0 |
|
- |
| 6(Packaging) |
- |
0 |
|
- |
| 1(Thickness at 2 kPa- IS 13162 (Part 3)) |
- |
0 |
|
- |
| 2(Width- IS 1954) |
- |
0 |
|
- |
| 2(Mass- IS 15891 (Part 1)) |
- |
0 |
|
- |
| 2(Thickness at 2 kPa-IS 15891 (Part 2)) |
- |
0 |
|
- |
| 2(Tensile strength MD*CD- IS 15891 (Part 3)) |
- |
0 |
|
- |
| 1(Width- IS 1954) |
- |
0 |
|
- |
| 1(Ends × Picks- IS 1963) |
- |
0 |
|
- |
| 1(Thickness at 2 kPa- IS 13162 (Part 3)) |
- |
0 |
|
- |
| 1(Tensile strength in MD × CD,- IS 13162 (Part 5)) |
- |
0 |
|
- |
| 1(Elongation at break in MD × CD- IS 13162 (Part 5)) |
- |
0 |
|
- |
| 1(Puncture resistance- IS 16078) |
- |
0 |
|
- |
| 1(Burst strength- IS 1966 (Part 1)) |
- |
0 |
|
- |
| 1(Permittivity at 50 mm constant head- IS 14324) |
- |
0 |
|
- |
| 1(Apparent opening size (A. O. S.) , O95- IS 14294) |
- |
0 |
|
- |
| 1(Apparent opening size (A. O. S.) , O95- IS 14294) |
- |
0 |
|
- |
| 4, Table 1, (ii)(Construction) |
- |
0 |
|
- |
| 4, Table 1, (ii)(Weight at 20 percent moisture regain, g/m2 , Min, for Treated Woven Jute Geotextiles) |
- |
0 |
|
- |
| 4, Table 1, (iii)(Width, cm, for Treated Woven Jute Geotextiles) |
- |
0 |
|
- |
| 4, Table 1, (iv)(Ends x Picks/dm, for Treated Woven Jute Geotextiles) |
- |
0 |
|
- |
| 4, Table 1, (v)(Thickness at 2kPa, mm, for Treated Woven Jute Geotextiles) |
- |
0 |
|
- |
| 4, Table 1, (vi)(Tensile Strength in MD x CD, kN/m, for Treated Woven Jute Geotextiles) |
- |
0 |
|
- |
| 4, Table 1, (vii)(Elongation at break in MD x CD, percent, for Treated Woven Jute Geotextiles) |
- |
0 |
|
- |
| 4, Table 1, (viii)(Puncture Resistance, kN, Min, for Treated Woven Jute Geotextiles) |
- |
0 |
|
- |
| 4, Table 1, (ix)(Burst Strength, kPa. Min, for Treated Woven Jute Geotextiles) |
- |
0 |
|
- |
| 4, Table 1, (x)(Permittivity at 50 mm constant head, sec –1 , Min, for Treated Woven Jute Geotextiles) |
- |
0 |
|
- |
| 4, Table 1, (xi)(Apparent opening size (A. O. S.) , O95 , Micron3, for Treated Woven Jute Geotextiles) |
- |
0 |
|
- |
| 5(Sampling) |
- |
0 |
|
- |
| 6(Packaging) |
- |
0 |
|
- |
|
- |
- Included w.e.f 02.06.2025 |
| 6250 |
OPTIMAS TESTING SERVICES, OPTIMAS OE SOLUTIONS INDIA PRIVATE LIMITED
| 7187406
| IS 18480 : Part 1 (2023) |
Cross Recessed Tapping Screws: Part 1 Pan Head |
- |
7200 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Clause. 3.0(Dimenssions.) |
- |
100 |
|
- |
| Clause. 3.0(Thread size.) |
- |
100 |
|
- |
| Clause. 3.0(Length) |
- |
100 |
|
- |
| Clause. 4.0(Material) |
- |
100 |
|
- |
| Clause. 4.0(Cross Recess) |
- |
100 |
|
- |
| Clause. 4.0(Tolerances) |
- |
100 |
|
- |
| Clause. 4.0(Mechnical and functional properties.) |
- |
100 |
|
- |
| Clause. 4.0(Finish) |
- |
100 |
|
- |
| Clause. 4.0(Acceptability) |
- |
100 |
|
- |
| Clause.5.0(Designation) |
- |
100 |
|
- |
| Clause.5.0(Marking) |
- |
100 |
|
- |
| Clause. 4.0(Thread) |
- |
100 |
|
- |
|
20 Aug, 2028 |
- Clauses No.4 (Thread-forming capacity Drive test) |
| 6251 |
HEXIQON LABORATORY PRIVATE LIMITED, AHMEDABAD
| 7167306
| IS 2556 : Part 14 (2024) |
Vitreous China Sanitary Appliances - Specification Part 14 Specific Requirements of Integrated Squatting Pans (Second Revision) |
Long pattern 500 mm and any other patterns and size |
12000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| As per Clause 3(General requirements: - Material and manufacture as per IS 2556 (Part 1)) |
- |
200 |
|
- |
| As per Clause 3(General requirements: - Application of Glazing as per IS 2556 (Part 1)) |
- |
200 |
|
- |
| As per Clause 3(General requirements: -Permissible blemishes or defects (WC pans, Bidets, Squatting pans, Urinals, Partition plates, Pedestals, Short Pedestals and Accessories)-General-Wavy finish as per IS 2556 (Part 1)) |
- |
200 |
|
- |
| As per Clause 3(General requirements-Permissible blemishes or defects (WC pans, Bidets, Squatting pans, Urinals, Partition plates, Pedestals, Short Pedestals and Accessories)-General-Warpage as per IS 2556 (Part 1)) |
- |
200 |
|
- |
| As per Clause 3(General requirements-Permissible blemishes or defects (WC apns, Bidets, Squatting pans, Urinals, Partition plates, Pedestals, Short Pedestals and Accessories)-General-Bit as per IS 2556 (Part 1)) |
- |
200 |
|
- |
| As per Clause 3(General requirements-Permissible blemishes or defects (WC apns, Bidets, Squatting pans, Urinals, Partition plates, Pedestals, Short Pedestals and Accessories)-General-Discoloration as per IS 2556 (Part 1)) |
- |
200 |
|
- |
| As per Clause 3(General requirements-Permissible blemishes or defects (WC pans, Bidets, Squatting pans, Urinals, Partition plates, Pedestals, Short Pedestals and Accessories)-Flushing surface and horizontal face of rims of WC pans, Squatting pans bidets and urinals-Spots, blisters and pinholes as per IS 2556 (Part 1)) |
- |
200 |
|
- |
| As per Clause 3(General requirements-Permissible blemishes or defects (WC pans, Bidets, Squatting pans, Urinals, Partition plates, Pedestals, Short Pedestals and Accessories)-Flushing surface and horizontal face of rims of WC pans, Squatting pans bidets and urinals-Bubbles and specks as per IS 2556 (Part 1)) |
- |
200 |
|
- |
| As per Clause 3(General requirements-Permissible blemishes or defects (WC pans, Bidets, Squatting pans, Urinals, Partition plates, Pedestals, Short Pedestals and Accessories)-Flushing surface and horizontal face of rims of WC pans, Squatting pans bidets and urinals-Polishing Marks as per IS 2556 (Part 1)) |
- |
200 |
|
- |
| As per Clause 3(General requirements-Permissible blemishes or defects (WC Pans, Bidets, Squatting pans, Urinals, Partition plates, Pedestals, Short Pedestals and Accessories)-Visible surfaces other than above-Spots, blisters and pinholes as per IS 2556 (Part 1)) |
- |
200 |
|
- |
| As per Clause 3(General requirements-Permissible blemishes or defects (WC pans, Bidets, Squatting pans, Urinals, Partition plates, Pedestals, Short Pedestals and Accessories)-Visible surfaces other than above-Bubbles and specks as per IS 2556 (Part 1)) |
- |
200 |
|
- |
| As per Clause 3(General requirements-Permissible blemishes or defects (WC pans, Bidets, Squatting pans, Urinals, Partition plates, Pedestals, Short Pedestals and Accessories)-Visible surfaces other than above-Polishing Marks as per IS 2556 (Part 1)) |
- |
200 |
|
- |
| As per Clause 3(General requirements - Minimum Thickness as per IS 2556 (Part 1)) |
- |
100 |
|
- |
| As per Clause 3(General requirements - Warpage as per IS 2556 (Part 1)) |
- |
200 |
|
- |
| As per Clause 3(General requirements - Crazing as per IS 2556 (Part 1)) |
- |
1200 |
|
- |
| As per Clause 3(General requirements - Water Absorption as per IS 2556 (Part 1)) |
- |
1500 |
|
- |
| As per Clause 3(General requirements - Modulus of Rupture IS 2556 (Part 1)) |
- |
600 |
|
- |
| As per Clause 3(General requirements - Chemical Resistance Test as per IS 2556 (Part 1)) |
- |
1500 |
|
- |
| As per Clause 3(General requirements - Resistance to Staining and Burning as per IS 2556 (Part 1)) |
- |
1000 |
|
- |
| As per Clause 4(PATTERN) |
- |
50 |
|
- |
| As per Clause 5.1 - Table 1 - i)(DIMENSIONS AND TOLERANCES - L) |
- |
200 |
|
- |
| As per Clause 5.1 - Table 1 - ii)(DIMENSIONS AND TOLERANCES - L1) |
- |
200 |
|
- |
| As per Clause 5.1 - Table 1 - iii)(DIMENSIONS AND TOLERANCES - L2) |
- |
200 |
|
- |
| As per Clause 5.1 - Table 1 - iv)(DIMENSIONS AND TOLERANCES - W1) |
- |
200 |
|
- |
| As per Clause 5.1 - Table 1 - v)(DIMENSIONS AND TOLERANCES - W2) |
- |
200 |
|
- |
| As per Clause 5.1 - Table 1 - vi)(DIMENSIONS AND TOLERANCES - h1) |
- |
200 |
|
- |
| As per Clause 5.1 - Table 1 - vii)(Slope of bottom of pan - ∝) |
- |
200 |
|
- |
| As per Clause 5.1 - Table 1 - viii)(DIMENSIONS AND TOLERANCES - T) |
- |
200 |
|
- |
| As per Clause 5.1 - Table 2 - i)(DIMENSIONS AND TOLERANCES - a) |
- |
200 |
|
- |
| As per Clause 6.1 - Table 2 - ii)(DIMENSIONS AND TOLERANCES - b) |
- |
200 |
|
- |
| As per Clause 6.1 - Table 2 - iii)(DIMENSIONS AND TOLERANCES - d1) |
- |
200 |
|
- |
| As per Clause 5 - Table 2 - iv)(DIMENSIONS AND TOLERANCES - d2) |
- |
200 |
|
- |
| As per Clause 5 - Table 2 - v)(DIMENSIONS AND TOLERANCES - d3) |
- |
200 |
|
- |
| As per Clause 5 - Table 2 - vi)(DIMENSIONS AND TOLERANCES - m) |
- |
200 |
|
- |
| As per Clause 5 - Table 2 - vii)(DIMENSIONS AND TOLERANCES - h2) |
- |
200 |
|
- |
| As per Clause 5 - Table 2 - viii)(DIMENSIONS AND TOLERANCES - ∅1) |
- |
200 |
|
- |
| As per Clause 6.3 - Table 3 - i)(DIMENSIONS AND TOLERANCES - d1) |
- |
200 |
|
- |
| As per Clause 6.3 - Table 3 - ii)(DIMENSIONS AND TOLERANCES - d2) |
- |
200 |
|
- |
| As per Clause 6.3 - Table 2 - iii)(DIMENSIONS AND TOLERANCES - d5) |
- |
200 |
|
- |
| As per Clause 6.3 - Table 2 - iv)(DIMENSIONS AND TOLERANCES - f) |
- |
200 |
|
- |
| As per Clause 6.3 - Table 2 - v)(DIMENSIONS AND TOLERANCES - h) |
- |
200 |
|
- |
| As per Clause 6.1(CONSTRUCTION) |
- |
200 |
|
- |
| As per Clause 6.2(CONSTRUCTION) |
- |
200 |
|
- |
| As per Clause 6.3(CONSTRUCTION) |
- |
200 |
|
- |
| As per Clause 7(FINISH) |
- |
200 |
|
- |
| As per Clause 8.2(Flushing tests - Toilet Paper Test) |
- |
400 |
|
- |
| As per Clause 8.3(Flushing tests - Smudge Test) |
- |
400 |
|
- |
| As per Clause 8.4(Flushing tests - Holding Capacity Test) |
- |
400 |
|
- |
| As per Clause 8.5(Flushing tests - Single Ball Test) |
- |
400 |
|
- |
| As per Clause 10(Additional requirements for water effeciency as per IS 17650 part 1) |
- |
3000 |
|
- |
|
07 Feb, 2030 |
- Included w.e.f.30.04.2025 |
| 6252 |
DELHI TEST HOUSE (A Unit of Delhii Test House Global LLP) (65) KUNDLI-2 SONIPAT
| 9138006
| IS 613 (2000) |
Copper rods and bars for electrical purposes - Specification (Third Revision) |
-- |
10000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Clause no.3(SUPPLY OF MATERIAL) |
- |
50 |
|
- |
| Clause no.6(FREEDOM FROM DEFECTS) |
- |
200 |
|
- |
| Clause no.7(CONDITION OF SUPPLY) |
- |
50 |
|
- |
| Clause no.8(CHEMICAL COMPOSITION) |
- |
4000 |
|
- |
| Clause no.9.1, table no,1("
tensile test ") |
- |
2100 |
|
- |
| Clause no.9.2(Bend test) |
- |
400 |
|
- |
| "Clause no.10.1 and 11.1.1 Table No. 2"(Dimensions and Tolerances) |
- |
400 |
|
- |
| "Clause no.10.2 and Table No. 3"("Tolerances on Length of Bar Rod in
Straight Length ") |
- |
250 |
|
- |
| "Clause no.10.4 and Table No. 4"(Corner Radius and Tolerances) |
- |
250 |
|
- |
| "Clause no.11 and Table No. 5"(Electrical Resistivity) |
- |
2100 |
|
- |
| Clause no. 13(packing) |
- |
50 |
|
- |
| Clause no. 14(Marking) |
- |
150 |
|
- |
| Clause no.3(SUPPLY OF MATERIAL) |
- |
50 |
|
- |
| Clause no.6(FREEDOM FROM DEFECTS) |
- |
200 |
|
- |
| Clause no.7(CONDITION OF SUPPLY) |
- |
50 |
|
- |
| Clause no.8(CHEMICAL COMPOSITION) |
- |
4000 |
|
- |
| Clause no.9.1, table no,1("
tensile test ") |
- |
2100 |
|
- |
| Clause no.9.2(Bend test) |
- |
400 |
|
- |
| "Clause no.10.1 and 11.1.1 Table No. 2"(Dimensions and Tolerances) |
- |
400 |
|
- |
| "Clause no.10.2 and Table No. 3"("Tolerances on Length of Bar Rod in
Straight Length ") |
- |
250 |
|
- |
| "Clause no.10.4 and Table No. 4"(Corner Radius and Tolerances) |
- |
250 |
|
- |
| "Clause no.11 and Table No. 5"(Electrical Resistivity) |
- |
2100 |
|
- |
| Clause no. 13(packing) |
- |
50 |
|
- |
| Clause no. 14(Marking) |
- |
150 |
|
- |
| Clause no.3(SUPPLY OF MATERIAL) |
- |
50 |
|
- |
| Clause no.6(FREEDOM FROM DEFECTS) |
- |
200 |
|
- |
| Clause no.7(CONDITION OF SUPPLY) |
- |
50 |
|
- |
| Clause no.8(CHEMICAL COMPOSITION) |
- |
4000 |
|
- |
| Clause no.9.1, table no,1("
tensile test ") |
- |
2100 |
|
- |
| Clause no.9.2(Bend test) |
- |
400 |
|
- |
| "Clause no.10.1 and 11.1.1 Table No. 2"(Dimensions and Tolerances) |
- |
400 |
|
- |
| "Clause no.10.2 and Table No. 3"("Tolerances on Length of Bar Rod in
Straight Length ") |
- |
250 |
|
- |
| "Clause no.10.4 and Table No. 4"(Corner Radius and Tolerances) |
- |
250 |
|
- |
| "Clause no.11 and Table No. 5"(Electrical Resistivity) |
- |
2100 |
|
- |
| Clause no. 13(packing) |
- |
50 |
|
- |
| Clause no. 14(Marking) |
- |
150 |
|
- |
|
31 Dec, 2029 |
- Included w.e.f.02.06.2025 |
| 6253 |
OPTIMAS TESTING SERVICES, OPTIMAS OE SOLUTIONS INDIA PRIVATE LIMITED
| 7187406
| IS 18471 : Part 2 (2023) |
Fasteners � Cross Recessed Drilling Screws with Tapping Screw Thread Part 2 Countersunk Head |
- |
7200 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Clause. 3.0(Dimenssions.) |
- |
100 |
|
NO ANY REMARK |
| Clause. 3.0(Thread size.) |
- |
100 |
|
NO ANY REMARK |
| Clause. 3.0(Length) |
- |
100 |
|
NO ANY REMARK |
| Clause. 4.0(Material) |
- |
100 |
|
NO ANY REMARK |
| Clause. 4.0(Thread) |
- |
100 |
|
NO ANY REMARK |
| Clause. 4.0(Cross recesses) |
- |
100 |
|
NO ANY REMARK |
| Clause. 4.0(Mechnical and functional properties.) |
- |
100 |
|
NO ANY REMARK |
| Clause. 4.0(Finish) |
- |
100 |
|
NO ANY REMARK |
| Clause. 4.0(Acceptability) |
- |
100 |
|
NO ANY REMARK |
| Clause.5.0(Designation) |
- |
100 |
|
NO ANY REMARK |
| Clause.5.0(Marking) |
- |
100 |
|
NO ANY REMARK |
|
20 Aug, 2028 |
- Clauses No.4 (Hydrogen embrittlement, Inspection of the drilled hole, drilling and screwing-in-test) |
| 6254 |
OPTIMAS TESTING SERVICES, OPTIMAS OE SOLUTIONS INDIA PRIVATE LIMITED
| 7187406
| IS 18471 : Part 1 (2023) |
Fasteners � Cross Recessed Drilling Screws with Tapping Screw Thread Part 1 Pan Head |
All |
7200 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Clause. 3.0(Dimenssions.) |
- |
100 |
|
NO ANY REMARK |
| Clause. 3.0(Dimenssions.) |
- |
100 |
|
NO ANY REMARK |
| Clause. 3.0(Thread size.) |
- |
100 |
|
NO ANY REMARK |
| Clause. 3.0(Length) |
- |
100 |
|
NO ANY REMARK |
| Clause. 4.0(Material) |
- |
100 |
|
NO ANY REMARK |
| Clause. 4.0(Thread) |
- |
100 |
|
NO ANY REMARK |
| Clause. 4.0(Cross recesses) |
- |
100 |
|
NO ANY REMARK |
| Clause. 4.0(Mechnical and functional properties.) |
- |
100 |
|
NO ANY REMARK |
| Clause. 4.0(Finish) |
- |
100 |
|
NO ANY REMARK |
| Clause. 4.0(Acceptability) |
- |
100 |
|
NO ANY REMARK |
| Clause.5.0(Designation) |
- |
100 |
|
NO ANY REMARK |
| Clause.5.0(Marking) |
- |
100 |
|
NO ANY REMARK |
|
20 Aug, 2028 |
- Clauses No.4 (Hydrogen embrittlement, Inspection of the drilled hole, drilling and screwing-in-test) |
| 6255 |
Sleen India Biz venture Private Limited, Agra
| 9139736
| IS 14715 : Part 1 (2016) |
Jute geotextiles Part 1 Strengthening of sub-grade in roads – Specification (second revision) |
All Type |
6500 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 1(Weight at 20% moisture Regain- IS 14716) |
- |
300 |
|
- |
| 1(Width- IS 1954) |
- |
100 |
|
- |
| 1(Ends × Picks- IS 1963) |
- |
200 |
|
- |
| 1(Tensile strength in MD × CD- IS 13162 (Part 5)) |
- |
1500 |
|
- |
| 1("Elongation at break in MD × CD-
IS 13162 (Part 5)") |
- |
0 |
|
Tensile test and elongation test price is 1500/-. |
| 1(Puncture resistance- IS 16078) |
- |
1000 |
|
- |
| 1(Burst strength- IS 1966 (Part 1)) |
- |
1000 |
|
- |
| 1(Permittivity at 50mm constant head- IS 14324) |
- |
1000 |
|
- |
| 1(Apparent opening size (A. O. S.) , O95- IS 14294) |
- |
500 |
|
- |
| 2(Elongation at break MD * CD - IS 15891 (Part 3)) |
- |
0 |
|
Tensile test and elongation test price is 1500/-. |
| 2(Permittivity at 50 mm constant head- IS 14324) |
- |
0 |
|
Test price for Permittivity test is 1000/-. |
| 2(Bursting strength- IS 1966 (Part 1)) |
- |
0 |
|
Test price for bursting test is 1000/-. |
| 2(Apparent opening size (A. O. S.), O95- IS 14294) |
- |
0 |
|
Test price for apparent size is 500/-. |
| 1(Weight at 20 percent moisture regain- IS 14716) |
- |
0 |
|
Test Price for Weight at 20 % moisture regain is 300/-. |
| 4, Table 1, (i)(Construction) |
- |
1 |
|
Test price for construction is 200/-. |
| 4, Table 1, (ii)(Weight at 20 percent moisture regain, g/m2 for Woven Jute Geotextiles) |
- |
0 |
|
Test Price for Weight at 20 % moisture regain is 300/-. |
| 4, Table 1, (iii)(Width cm, for Woven Jute Geotextiles) |
- |
0 |
|
Test price for width test is 100/-. |
| 4, Table 1, (iv)(Ends X Picks/ dm, for Woven Jute Geotextiles) |
- |
0 |
|
Test price for Endx picks/dm test is 200/-. |
| 4, Table 1, (v)(Thickness at 2kPA, mm, for Woven Jute Geotextiles) |
- |
200 |
|
- |
| 4, Table 1, (vi)(Tensile strength in MD × CD, kN/m, Min, for Woven Jute Geotextiles) |
- |
0 |
|
Test price for tensile test and elongation is 1500/-. |
| 4, Table 1, (vii)(Elongation at break in MD × CD, for Woven Jute Geotextiles) |
- |
0 |
|
Test price for tensile test and elongation is 1500/-. |
| 4, Table 1, (viii)(Puncture resistance, kN, Min, for Woven Jute Geotextiles) |
- |
0 |
|
Test price for puncturing test is 1000/-. |
| 4, Table 1, (ix)(Burst strength, kPa, Min, for Woven Jute Geotextiles) |
- |
0 |
|
Test price for bursting test is 1000/-. |
| 4, Table 1, (x)(Permittivity at 50mm constant head, sec -1 , Min, for Woven Jute Geotextiles) |
- |
0 |
|
Test price for bursting test is 1000/-. |
| 4, Table 1, (xi)(Apparent opening size (A. O. S.) , O 95 , Micron, for Woven Jute Geotextiles) |
- |
0 |
|
Test price for apparent size is 500/-. |
| 4, Table 2, (i)(Width, cm, for Non-Woven Jute Geotextiles) |
- |
0 |
|
Test price for width test is 100/-. |
| 4, Table 2, (ii)(Mass, g/m2, for Non-Woven Jute Geotextiles) |
- |
0 |
|
Test price for Mass and weight measurement is 300/-. |
| 4, Table 2, (iii)(Thickness at 2 kPa, mm, for Non-Woven Jute Geotextiles) |
- |
0 |
|
Test price for thickness measurement is 200/-. |
| 4, Table 2, (iv)(Tensile strength, kN/m, Min, for Non-Woven Jute Geotextiles) |
- |
0 |
|
Test price for tensile test and elongation is 1500/-. |
| 4, Table 2, (v)(Elongation at break, percent, for Non-Woven Jute Geotextiles) |
- |
0 |
|
Test price for tensile test and elongation is 1500/-. |
| 4, Table 2, (vi)(Permittivity at 50 mm constant head, sec–1 , Min, for Non-Woven Jute Geotextiles) |
- |
0 |
|
Test price for bursting test is 1000/-. |
| 4, Table 2, (vii)(Bursting strength, kPa, Min, for Non-Woven Jute Geotextiles) |
- |
0 |
|
Test price for bursting test is 1000/-. |
| 4, Table 2, (viii)(Apparent opening size (A. O. S.), O 95 , Micron, for Non-Woven Jute Geotextiles) |
- |
0 |
|
Test price for apparent size is 500/-. |
| 5(Sampling) |
- |
200 |
|
- |
| 6(Packaging) |
- |
300 |
|
- |
| 1(Weight at 20% moisture Regain- IS 14716) |
- |
0 |
|
- |
| 1(Width- IS 1954) |
- |
0 |
|
- |
| 1(Ends × Picks- IS 1963) |
- |
0 |
|
- |
| 1(Tensile strength in MD × CD- IS 13162 (Part 5)) |
- |
0 |
|
- |
| 1("Elongation at break in MD × CD-
IS 13162 (Part 5)") |
- |
0 |
|
- |
| 1(Puncture resistance- IS 16078) |
- |
0 |
|
- |
| 1(Burst strength- IS 1966 (Part 1)) |
- |
0 |
|
- |
| 1(Permittivity at 50mm constant head- IS 14324) |
- |
0 |
|
- |
| 1(Apparent opening size (A. O. S.) , O95- IS 14294) |
- |
0 |
|
- |
| 2(Elongation at break MD * CD - IS 15891 (Part 3)) |
- |
0 |
|
- |
| 2(Permittivity at 50 mm constant head- IS 14324) |
- |
0 |
|
- |
| 2(Bursting strength- IS 1966 (Part 1)) |
- |
0 |
|
- |
| 2(Apparent opening size (A. O. S.), O95- IS 14294) |
- |
0 |
|
- |
| 1(Weight at 20 percent moisture regain- IS 14716) |
- |
0 |
|
- |
| 4, Table 1, (i)(Construction) |
- |
0 |
|
- |
| 4, Table 1, (ii)(Weight at 20 percent moisture regain, g/m2 for Woven Jute Geotextiles) |
- |
0 |
|
- |
| 4, Table 1, (iii)(Width cm, for Woven Jute Geotextiles) |
- |
0 |
|
- |
| 4, Table 1, (iv)(Ends X Picks/ dm, for Woven Jute Geotextiles) |
- |
0 |
|
- |
| 4, Table 1, (v)(Thickness at 2kPA, mm, for Woven Jute Geotextiles) |
- |
0 |
|
- |
| 4, Table 1, (vi)(Tensile strength in MD × CD, kN/m, Min, for Woven Jute Geotextiles) |
- |
0 |
|
- |
| 4, Table 1, (vii)(Elongation at break in MD × CD, for Woven Jute Geotextiles) |
- |
0 |
|
- |
| 4, Table 1, (viii)(Puncture resistance, kN, Min, for Woven Jute Geotextiles) |
- |
0 |
|
- |
| 4, Table 1, (ix)(Burst strength, kPa, Min, for Woven Jute Geotextiles) |
- |
0 |
|
- |
| 4, Table 1, (x)(Permittivity at 50mm constant head, sec -1 , Min, for Woven Jute Geotextiles) |
- |
0 |
|
- |
| 4, Table 1, (xi)(Apparent opening size (A. O. S.) , O 95 , Micron, for Woven Jute Geotextiles) |
- |
0 |
|
- |
| 4, Table 2, (i)(Width, cm, for Non-Woven Jute Geotextiles) |
- |
0 |
|
- |
| 4, Table 2, (ii)(Mass, g/m2, for Non-Woven Jute Geotextiles) |
- |
0 |
|
- |
| 4, Table 2, (iii)(Thickness at 2 kPa, mm, for Non-Woven Jute Geotextiles) |
- |
0 |
|
- |
| 4, Table 2, (iv)(Tensile strength, kN/m, Min, for Non-Woven Jute Geotextiles) |
- |
0 |
|
- |
| 4, Table 2, (v)(Elongation at break, percent, for Non-Woven Jute Geotextiles) |
- |
0 |
|
- |
| 4, Table 2, (vi)(Permittivity at 50 mm constant head, sec–1 , Min, for Non-Woven Jute Geotextiles) |
- |
0 |
|
- |
| 4, Table 2, (vii)(Bursting strength, kPa, Min, for Non-Woven Jute Geotextiles) |
- |
0 |
|
- |
| 4, Table 2, (viii)(Apparent opening size (A. O. S.), O 95 , Micron, for Non-Woven Jute Geotextiles) |
- |
0 |
|
- |
| 5(Sampling) |
- |
0 |
|
- |
| 6(Packaging) |
- |
0 |
|
- |
| 1(Weight at 20% moisture Regain- IS 14716) |
- |
0 |
|
- |
| 1(Width- IS 1954) |
- |
0 |
|
- |
| 1(Ends × Picks- IS 1963) |
- |
0 |
|
- |
| 1(Tensile strength in MD × CD- IS 13162 (Part 5)) |
- |
0 |
|
- |
| 1("Elongation at break in MD × CD-
IS 13162 (Part 5)") |
- |
0 |
|
- |
| 1(Puncture resistance- IS 16078) |
- |
0 |
|
- |
| 1(Burst strength- IS 1966 (Part 1)) |
- |
0 |
|
- |
| 1(Permittivity at 50mm constant head- IS 14324) |
- |
0 |
|
- |
| 1(Apparent opening size (A. O. S.) , O95- IS 14294) |
- |
0 |
|
- |
| 2(Elongation at break MD * CD - IS 15891 (Part 3)) |
- |
0 |
|
- |
| 2(Permittivity at 50 mm constant head- IS 14324) |
- |
0 |
|
- |
| 2(Bursting strength- IS 1966 (Part 1)) |
- |
0 |
|
- |
| 2(Apparent opening size (A. O. S.), O95- IS 14294) |
- |
0 |
|
- |
| 1(Weight at 20 percent moisture regain- IS 14716) |
- |
0 |
|
- |
| 4, Table 1, (i)(Construction) |
- |
0 |
|
- |
| 4, Table 1, (ii)(Weight at 20 percent moisture regain, g/m2 for Woven Jute Geotextiles) |
- |
0 |
|
- |
| 4, Table 1, (iii)(Width cm, for Woven Jute Geotextiles) |
- |
0 |
|
- |
| 4, Table 1, (iv)(Ends X Picks/ dm, for Woven Jute Geotextiles) |
- |
0 |
|
- |
| 4, Table 1, (v)(Thickness at 2kPA, mm, for Woven Jute Geotextiles) |
- |
0 |
|
- |
| 4, Table 1, (vi)(Tensile strength in MD × CD, kN/m, Min, for Woven Jute Geotextiles) |
- |
0 |
|
- |
| 4, Table 1, (vii)(Elongation at break in MD × CD, for Woven Jute Geotextiles) |
- |
0 |
|
- |
| 4, Table 1, (viii)(Puncture resistance, kN, Min, for Woven Jute Geotextiles) |
- |
0 |
|
- |
| 4, Table 1, (ix)(Burst strength, kPa, Min, for Woven Jute Geotextiles) |
- |
0 |
|
- |
| 4, Table 1, (x)(Permittivity at 50mm constant head, sec -1 , Min, for Woven Jute Geotextiles) |
- |
0 |
|
- |
| 4, Table 1, (xi)(Apparent opening size (A. O. S.) , O 95 , Micron, for Woven Jute Geotextiles) |
- |
0 |
|
- |
| 4, Table 2, (i)(Width, cm, for Non-Woven Jute Geotextiles) |
- |
0 |
|
- |
| 4, Table 2, (ii)(Mass, g/m2, for Non-Woven Jute Geotextiles) |
- |
0 |
|
- |
| 4, Table 2, (iii)(Thickness at 2 kPa, mm, for Non-Woven Jute Geotextiles) |
- |
0 |
|
- |
| 4, Table 2, (iv)(Tensile strength, kN/m, Min, for Non-Woven Jute Geotextiles) |
- |
0 |
|
- |
| 4, Table 2, (v)(Elongation at break, percent, for Non-Woven Jute Geotextiles) |
- |
0 |
|
- |
| 4, Table 2, (vi)(Permittivity at 50 mm constant head, sec–1 , Min, for Non-Woven Jute Geotextiles) |
- |
0 |
|
- |
| 4, Table 2, (vii)(Bursting strength, kPa, Min, for Non-Woven Jute Geotextiles) |
- |
0 |
|
- |
| 4, Table 2, (viii)(Apparent opening size (A. O. S.), O 95 , Micron, for Non-Woven Jute Geotextiles) |
- |
0 |
|
- |
| 5(Sampling) |
- |
0 |
|
- |
| 6(Packaging) |
- |
0 |
|
- |
|
- |
- Included w.e.f 02.06.2025 |
| 6256 |
JBS TESTING SOLUTIONS PVT LTD (27), JALANDHAR
| 9164606
| IS 1367 : Part 13 (2020) |
Technical Supply Conditions for Threaded Steel Fasteners Part 13 Hot Dip Galvanized Coatings on Threaded Fasteners ( Third Revision ) |
- |
7500 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4.1.1(Chemical Composition) |
- |
7500 |
|
For complete testing |
| 7.0(Mechanical Propoerties ( Proof load & Tesnsile Strength)) |
- |
7500 |
|
For complete testing |
| 8.1(Appearance of zinc coating) |
- |
7500 |
|
For complete testing |
| 8.3(Zinc coating thickness) |
- |
7500 |
|
For complete testing |
| 8.4(Adhesion of Zinc Coating) |
- |
7500 |
|
For complete testing |
|
- |
- Included w.e.f.16.07.2025 |
| 6257 |
JBS TESTING SOLUTIONS PVT LTD (27), JALANDHAR
| 9164606
| IS 1367 : Part 6 (2018) |
Technical supply conditions for threaded steel fasteners: Part 6 mechanical properties of fasteners made of carbon steel and alloy steel - Nuts with specified property classes - Coarse thread and fine pitch thread (Fourth Revision) |
- |
7500 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 6.0(Material Testing) |
- |
7500 |
|
For complete test |
| 9.1(Proof Load) |
- |
7500 |
|
For complete test |
| 9.2(Hardness Test) |
- |
7500 |
|
For complete test |
| 9.3(Surface Integrity) |
- |
7500 |
|
For complete test |
| Cl-4.3(Ranges of nominal diameters in relation to nut style and property class) |
- |
7500 |
|
For complete test |
|
- |
- Included w.e.f.16.07.2025 |
| 6258 |
JBS TESTING SOLUTIONS PVT LTD (27), JALANDHAR
| 9164606
| IS 1367 : Part 3 (2017) |
Technical supply conditions for threaded steel fasteners: Part 3 mechanical properties of fasteners made of carbon steel and bolts, screws and studs (Fifth Revision) |
- |
21500 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 6.0(Material Testing) |
- |
6500 |
|
For complete material tests |
| 7.0(Mechanical testing (Ys, TS, %EL, RA)) |
- |
10000 |
|
For complete mechanical testing and Cl 9. |
| 9.6(Proof Load test for finished bolts scrwes, and studs) |
- |
10000 |
|
For complete mechanical testing and Cl 9. |
| 9.8(Head soundness test) |
- |
10000 |
|
For complete mechanical testing and Cl 9. |
| 9.9(Hardness Test) |
- |
1000 |
|
For hardness test |
| 9.10(Decarburization test) |
- |
2500 |
|
For carb and Decarb |
| 9.11(Carburization test) |
- |
2500 |
|
For carb and Decarb |
| 9.12(Reducing of hardnes after retempering , Hv) |
- |
10000 |
|
For complete mechanical testing and Cl 9. |
| 9.13(Torsional Test) |
- |
10000 |
|
For complete mechanical testing and Cl 9. |
| 9.14(Impact Test) |
- |
10000 |
|
For complete mechanical testing and Cl 9. |
| 9.15(Surface discounity) |
- |
10000 |
|
For complete mechanical testing and Cl 9. |
| 6.0(Material Testing) |
- |
0 |
|
- |
| 7.0(Mechanical testing (Ys, TS, %EL, RA)) |
- |
0 |
|
- |
| 9.6(Proof Load test for finished bolts scrwes, and studs) |
- |
0 |
|
- |
| 9.8(Head soundness test) |
- |
0 |
|
- |
| 9.9(Hardness Test) |
- |
0 |
|
- |
| 9.10(Decarburization test) |
- |
0 |
|
- |
| 9.11(Carburization test) |
- |
0 |
|
- |
| 9.12(Reducing of hardnes after retempering , Hv) |
- |
0 |
|
- |
| 9.13(Torsional Test) |
- |
0 |
|
- |
| 9.14(Impact Test) |
- |
0 |
|
- |
| 9.15(Surface discounity) |
- |
0 |
|
- |
| Clause 7(Mechanical and physical properties) |
- |
0 |
|
- |
| Clause 9(Test Method) |
- |
0 |
|
- |
| Clause 9.1(Tensile Test under wedge loading of finished bolts and screws (excluding studs)) |
- |
0 |
|
- |
| Clause 9.2(Tensile Test for finished bolts, screws and studs for determination of tensile) |
- |
0 |
|
- |
| Clause 9.3(Tensile Test for full-size bolts, screws and studs for determination of elongation after fracture A and stress at 0,0048d non-proportional elongation) |
- |
0 |
|
- |
| Clause 9.4(Tensile Test for bolts and screws with reduced loadability due to head design) |
- |
0 |
|
- |
| Clause 9.5(Tensile test of fasteners with waisted shank) |
- |
0 |
|
- |
| Clause 9.7(Tensile test for machined test pieces) |
- |
0 |
|
- |
| Clause 10(MARKING) |
- |
0 |
|
- |
|
- |
- - |
| 6259 |
Stellar Test House, Noida
| 8171606
| IS 9968 : Part 1 (1988) |
Specification for elastomer insulatedcables: Part 1 for working voltages up to and including 1100 volts (First Revision) |
NA |
12000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 3.1( Copper Cooduetor) |
- |
250 |
|
Single core Rs.12,000/- additional each extra core Rs.1,500/ |
| 3.2(Aluminium conductor) |
- |
250 |
|
- |
| 4.1(INSULATION : lnsulation for General Service) |
- |
250 |
|
- |
| 4.2(INSULATION : Heat Resisting insulation) |
- |
250 |
|
- |
| 4.3(INSULATION : Silicone Rubber Insulation) |
- |
250 |
|
- |
| 5.1(TAPE : Proofed Tape) |
- |
250 |
|
- |
| 5.2(TAPE : 2 Polyethyl_ Terephthalate ( PETP ) Tape or
Plastic: Tape or Any Other SlIIitable Tape ) |
- |
250 |
|
- |
| 5.3(TAPE : Giass Tape) |
- |
250 |
|
- |
| 6.1(FILLERS : ) |
- |
250 |
|
- |
| 7.1(BRAID : Textile Braid) |
- |
250 |
|
- |
| 7.2(BRAID : Glass Braid ) |
- |
250 |
|
- |
| 8.1(SHEATH : General Service Insulated Cables and Flexible
Cords) |
- |
250 |
|
- |
| 8.2(SHEATH :Heat Resisting Insulated Cables) |
- |
250 |
|
- |
| 9.1(PresenRtive Compound) |
- |
250 |
|
- |
| 9.2(Varnish) |
- |
100 |
|
- |
| 10( Conductor ) |
- |
250 |
|
- |
| 11(Separator tape) |
- |
100 |
|
- |
| 12.2(Insulation : Thickness of Insufatien) |
- |
100 |
|
- |
| 12.4(Insulation : Allplication of Insulation) |
- |
100 |
|
- |
| 13(CORE IDENTiFICATlON) |
- |
100 |
|
- |
| 14(Tape) |
- |
100 |
|
- |
| 15(BRAIDING) |
- |
250 |
|
- |
| 16(COMPOUNDING AND VARNISHING) |
- |
250 |
|
- |
| 17(LAYING UP OF CORES) |
- |
250 |
|
- |
| 18( Binder tape) |
- |
250 |
|
- |
| 19.2(Sheath : Thickness of Sheath) |
- |
250 |
|
- |
| 19.4( Sheath :Colour) |
- |
250 |
|
- |
| 20( Overall diameter) |
- |
250 |
|
- |
| 21. (a)(Persulphate tests (for copper)) |
- |
250 |
|
- |
| 21. (b)(Annealing Test (for coper)) |
- |
250 |
|
- |
| 21. (c)( Tensile Test (for aluminium)) |
- |
250 |
|
- |
| 21. (d)( Wrapping Test (for aluminium)) |
- |
250 |
|
- |
| 21. (e)(Conductor Resistance ) |
- |
250 |
|
- |
| 21.1( Tensile strength ) |
- |
500 |
|
- |
| 22.1( Elongation) |
- |
500 |
|
- |
| 21.1(type test : Ageing In air oven) |
- |
500 |
|
- |
| 21.1(type test : Ageing in air bomb) |
- |
500 |
|
- |
| 21.1(type test : Ageing In oxygen
bomb) |
- |
500 |
|
- |
| 21.1(type test : Hot set elongation) |
- |
500 |
|
- |
| 21.1(type test : Tear resistance ) |
- |
500 |
|
- |
| 22.2(type test :Insulauon resistance High voltage (water immersron ) test) |
- |
500 |
|
- |
| 22.2(type test : Flammability test
( applicable to cables
finished With SE 3 and
SE 4 sheaths only)
) |
- |
500 |
|
- |
| 21(Water absorption test) |
- |
500 |
|
- |
| 23(identification) |
- |
500 |
|
- |
| Cl No. 4.1(Ageing in oxygen bomb - Elongation) |
- |
500 |
|
- |
| Cl No. 4.1(Ageing in oxygen bomb - Tensile strength ) |
- |
500 |
|
- |
| Cl No. 4.1(Ageing in air bomb - Elongation) |
- |
500 |
|
- |
| Cl No. 4.1(Ageing in air bomb - Tensile strength ) |
- |
500 |
|
- |
| Cl No. 4.1(Ageing in air oven - Elongation) |
- |
500 |
|
- |
| Cl No. 4.1(Ageing in air oven - Tensile strength ) |
- |
500 |
|
- |
| Cl No. 22.2(High Voltage Test (Water Immersion)) |
- |
500 |
|
- |
| Cl No. 4.1(Insulation resistance) |
- |
500 |
|
- |
| Cl No. 22.4, Appendix B (Flexing test for cords for use with electric iron ) |
- |
500 |
|
- |
| Cl No. 22.2.2/22.2.3(High Voltage Test / Spark test) |
- |
500 |
|
- |
| Cl No. 23.1, 23.2(Identification) |
- |
500 |
|
- |
| 21.1((f) Oil resistance) |
- |
500 |
|
- |
| Cl.9.1(Compound and Varnish) |
- |
500 |
|
- |
| Cl.9.2(Compound and Varnish) |
- |
500 |
|
- |
| Cl.21.1 & Table 2 of IS: 6380-1984(Water Absorption Test) |
- |
500 |
|
- |
| Cl.19.1(Application of Sheath) |
- |
500 |
|
- |
| Cl.21.1 & Table 3 of IS: 6380-1984(Physical Test on outer sheath (Without Ageing)) |
- |
500 |
|
- |
| Cl.21.1 & Table 3 of IS: 6380-1984(Physical Test on outer sheath (Without Ageing)) |
- |
500 |
|
- |
| Cl.21.1 & Table 3 of IS: 6380-1984(Physical Test on outer sheath (Without Ageing)) |
- |
500 |
|
- |
| Cl.21.1 & Table 3 of IS: 6380-1984(Physical Test on outer sheath (After ageing in air oven)) |
- |
500 |
|
- |
| Cl.21.1 & Table 3 of IS: 6380-1984(Physical Test on outer sheath (After ageing in air oven)) |
- |
500 |
|
- |
| Cl.21.1 & Table 3 of IS: 6380-1984(Physical Test on outer sheath (After ageing in air Bomb )) |
- |
500 |
|
- |
| Cl.21.1 & Table 3 of IS: 6380-1984(Physical Test on outer sheath (After ageing in air Bomb )) |
- |
500 |
|
- |
| Cl.21.1 & Table 3 of IS: 6380-1984(Physical Test on outer sheath (Oil Resistance Test )) |
- |
500 |
|
- |
| Cl.21.1 & Table 3 of IS: 6380-1984(Physical Test on outer sheath (Oil Resistance Test )
Variation on Elongation (Percentage)) |
- |
500 |
|
- |
| Cl.21.1 & Table 3 of IS: 6380-1984(Physical Test on outer sheath (Hot Set Test)) |
- |
500 |
|
- |
| Cl.21.1 & Table 3 of IS: 6380-1984(Physical Test on outer sheath (Hot Set Test)) |
- |
500 |
|
- |
| Cl.21.1 & Table 2 of IS: 6380-1984(Insulation Resistance Test) |
- |
500 |
|
- |
| Cl.21.1 & Table 2 of IS: 6380-1984(Insulation Resistance Test) |
- |
500 |
|
- |
|
26 Sep, 2028 |
- Included w.e.f 16.07.2025 |
| 6260 |
JBS TESTING SOLUTIONS PVT LTD (27), JALANDHAR
| 9164606
| IS 1367 : Part 5 (2018) |
Technical supply conditions for threaded steel fasteners: Part 5 mechanical properties of fasteners made of carbon steel and alloy steel - Set screws and similar threaded fasteners with specified hardness classes - Coarse thread and fine pitch thread (Fourth Revision) |
- |
21500 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 6.0(Material test) |
- |
6500 |
|
For complete Chemical testing |
| 7.0(Mechanical Testing (Ys, Ts, %El)) |
- |
10000 |
|
For complete mechanical testing and Cl 9. |
| 9.1(Hardness) |
- |
10000 |
|
For complete mechanical testing and Cl 9. |
| 9.2(Decarburization test) |
- |
2500 |
|
For carb and Decarb testing |
| 9.3(Carburization test) |
- |
2500 |
|
For carb and Decarb testing |
| 9.4(Proof Torque Test) |
- |
10000 |
|
For complete mechanical testing and Cl 9. |
| 9.5(Proof Torque Test) |
- |
10000 |
|
For complete mechanical testing and Cl 9. |
| 3.0(Surface Integrity) |
- |
10000 |
|
For complete mechanical testing and Cl 9. |
| 6.0(Material test) |
- |
0 |
|
- |
| 7.0(Mechanical Testing (Ys, Ts, %El)) |
- |
0 |
|
- |
| 9.1(Hardness) |
- |
0 |
|
- |
| 9.2(Decarburization test) |
- |
0 |
|
- |
| 9.3(Carburization test) |
- |
0 |
|
- |
| 9.4(Proof Torque Test) |
- |
0 |
|
- |
| 9.5(Proof Torque Test) |
- |
0 |
|
- |
| 3.0(Surface Integrity) |
- |
0 |
|
- |
| Clause 7(Mechanical and physical properties) |
- |
0 |
|
- |
| Clause 8(Applicability of test method) |
- |
0 |
|
- |
| Clause 10(MARKING) |
- |
0 |
|
- |
|
- |
- Included w.e.f.16.07.2025 |
| 6261 |
Aaditech Test and Calibration Lab LLP
| 8179926
| IS 302 : Part 1 (2024) |
Household and Similar Electrical Appliances â Safety Part 1 General Requirements (Seventh Revision) |
- |
22000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 12(Charging of metal-ion batteries) |
- |
1000 |
|
- |
| 6(Classification- IS 302-1) |
- |
500 |
|
- |
| 5(General conditions for the tests) |
- |
500 |
|
- |
| 11.8(Temperature rise) |
- |
1000 |
|
- |
| 11.7(Duration corresponding) |
- |
1000 |
|
- |
| 11.6(Combined appliances) |
- |
1000 |
|
- |
| 11.5(Motor-operated appliances) |
- |
1000 |
|
- |
| 11.4(Heating appliances) |
- |
1000 |
|
- |
| 8.1.5(Live parts of built-in appliances) |
- |
1000 |
|
- |
| 18(Endurance) |
- |
2000 |
|
- |
| 17(Overload protection of transformers and associated circuits) |
- |
1000 |
|
- |
| 16(Leakage current and electric strength) |
- |
1000 |
|
- |
| 4(General requirement) |
- |
500 |
|
- |
| 32.1(Radiation Toxicity and Similar Hazards) |
- |
1000 |
|
- |
| 31(Resistance to Rusting) |
- |
1000 |
|
- |
| 30.2(Needle Flame Test) |
- |
1000 |
|
- |
| 30.2(Glow Wire Test) |
- |
1000 |
|
- |
| 30.1(Ball pressure test) |
- |
1000 |
|
- |
| 29(clearance, creepage distances and solid insulation) |
- |
1000 |
|
- |
| 28(Screw test and connections) |
- |
1000 |
|
- |
| 27.1(Provision for Earthing, IS 302-1) |
- |
1000 |
|
- |
| 26(Terminals for external conductors) |
- |
1000 |
|
- |
| 25.8(Supply Connection and External Flexible Cords, IS 302-1) |
- |
1000 |
|
- |
| 24(Components) |
- |
1000 |
|
- |
| 23.1(Internal Wiring, IS 302-1) |
- |
1000 |
|
- |
| 22.1(Construction, IS 302-1) |
- |
2000 |
|
- |
| 21.1(Mechanical Strength, IS 302-1) |
- |
1000 |
|
- |
| 20.1(Stability & Mechanical Hazards, IS 302-1) |
- |
1000 |
|
- |
| 19(Abnormal Operation) |
- |
2000 |
|
- |
| 18(Endurance) |
- |
2000 |
|
- |
| 16.3(Electric Strength (after clause 15 and 16.2)) |
- |
1000 |
|
- |
| 16.2(Leakage Current (after Clause 15)) |
- |
1000 |
|
- |
| 16.1(General) |
- |
1000 |
|
- |
| 16.0(General) |
- |
1000 |
|
- |
| 15.3(Humidity Test) |
- |
2000 |
|
- |
| 15.2(Spillage Test) |
- |
1000 |
|
- |
| 15.1(Ingress Protection test other than IPX0 (IP test)) |
- |
1000 |
|
- |
| 15.0(Moisture resistance) |
- |
1000 |
|
- |
| 14(Transient Over Voltages) |
- |
1000 |
|
- |
| 13.3(Electric Strength at operating temperature) |
- |
1000 |
|
- |
| 13.2(Leakage current at operating temperature) |
- |
1000 |
|
- |
| 13(Leakage current and electric strength at operating temperature) |
- |
1000 |
|
- |
| 11.3(Heating) |
- |
1000 |
|
- |
| 11.2(General) |
- |
500 |
|
- |
| 11.1(General) |
- |
500 |
|
- |
| 10.2(Current input) |
- |
1000 |
|
- |
| 10.1(Power input) |
- |
1000 |
|
- |
| 9(Starting of motor operation test requirements and tests) |
- |
1000 |
|
- |
| 8.1.4(Protection against live parts against protective impedance) |
- |
1000 |
|
- |
| 8.1.3(Protection against live parts in visible glowing heating elements) |
- |
1000 |
|
- |
| 8.1.2(Protection against live parts in openings) |
- |
1000 |
|
- |
| 8.1.1(Protection against live parts in all positions) |
- |
1000 |
|
- |
| 7(Marking and instructions) |
- |
1000 |
|
- |
| A.2(Earth continuity test) |
- |
1000 |
|
- |
| Annex C(Ageing test on motors) |
- |
2000 |
|
- |
| Annex D(Thermal motor protectors) |
- |
2000 |
|
- |
| 15.2(Moisture resistance) |
- |
2000 |
|
- |
| 19.17(Abnormal Operation, IS 302-1) |
- |
2000 |
|
- |
| 20.2(Stability & Mechanical Hazards, IS 302-1) |
- |
1000 |
|
- |
| 21.2(Mechanical Strength, IS 302-1) |
- |
1000 |
|
- |
| 21.3(Mechanical Strength, IS 302-1) |
- |
1000 |
|
- |
| 22.5(Construction) |
- |
1000 |
|
- |
| 22.6(Construction, IS 302-1) |
- |
1000 |
|
- |
| 22.11(Construction, IS 302-1) |
- |
1000 |
|
- |
| 22.16(Construction) |
- |
1000 |
|
- |
| 22.32(Construction, IS 302-1) |
- |
1000 |
|
- |
| 22.42(Construction) |
- |
1000 |
|
- |
| 23.3(Internal Wiring, IS 302-1) |
- |
1000 |
|
- |
| 25.6(Supply connection and external flexible cords, IS 302-1) |
- |
1000 |
|
- |
| 25.7(Supply Connection and External Flexible Cords, IS 302-1) |
- |
1000 |
|
- |
| 25.14(Supply Connection and External Flexible Cords, IS 302-1) |
- |
1000 |
|
- |
| 25.15(Supply Connection and External Flexible Cords, IS 302-1) |
- |
1000 |
|
- |
| 26.5(Terminals for external conductors) |
- |
1000 |
|
- |
| 27.5(Provision for Earthing, IS 302-1) |
- |
1000 |
|
- |
| 28.1(Screws and connections) |
- |
1000 |
|
- |
| 22.2(Construction, IS 302-1) |
- |
1000 |
|
- |
| 22.3(Construction, IS 302-1) |
- |
1000 |
|
- |
| B.22.4(Construction, IS 302-1) |
- |
1000 |
|
- |
| B.22.5(Construction, IS 302-1) |
- |
1000 |
|
- |
| 17(Over Load Protection of Transformers and associated circuits) |
- |
1000 |
|
- |
|
- |
- Included w.e.f 19.05.2025
Exclusion: Cl 19.11.4.1-Cl 19.11.4.7(EMI/EMC)
"Domestic Electric Clothes Washing Machines
(For testing charges please refer part 2 standard in LIMS)" |
| 6262 |
JBS TESTING SOLUTIONS PVT LTD (27), JALANDHAR
| 9164606
| IS 638 (2024) |
SHEET RUBBER JOINTING AND RUBBER INSERTION JOINTING - SPECIFICATION (Third Revision) |
- |
19250 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 2.1(Types) |
- |
19250 |
|
5000 - -For tensile and Elongation at break
3000 - For accelerated ageing
3000 - For compression set
3500 - For resistance to bending
3500 - For adhesion testing
1250 - For hardness testing |
| 2.2(Grades) |
- |
19250 |
|
5000 - -For tensile and Elongation at break
3000 - For accelerated ageing
3000 - For compression set
3500 - For resistance to bending
3500 - For adhesion testing
1250 - For hardness testing |
| 3.1.1(Jointing Material) |
- |
19250 |
|
5000 - -For tensile and Elongation at break
3000 - For accelerated ageing
3000 - For compression set
3500 - For resistance to bending
3500 - For adhesion testing
1250 - For hardness testing |
| 3.1.2(Composition of Rubber Compound) |
- |
19250 |
|
5000 - -For tensile and Elongation at break
3000 - For accelerated ageing
3000 - For compression set
3500 - For resistance to bending
3500 - For adhesion testing
1250 - For hardness testing |
| 3.1.3(Fabric Reinforcementfor Rubber Insertion Jointing) |
- |
19250 |
|
5000 - -For tensile and Elongation at break
3000 - For accelerated ageing
3000 - For compression set
3500 - For resistance to bending
3500 - For adhesion testing
1250 - For hardness testing |
| 3.2.2(Thickness and Number of Plies) |
- |
19250 |
|
5000 - -For tensile and Elongation at break
3000 - For accelerated ageing
3000 - For compression set
3500 - For resistance to bending
3500 - For adhesion testing
1250 - For hardness testing |
| 3.2.2.1(Positon of Plies) |
- |
19250 |
|
5000 - -For tensile and Elongation at break
3000 - For accelerated ageing
3000 - For compression set
3500 - For resistance to bending
3500 - For adhesion testing
1250 - For hardness testing |
| 3.3(Size of Sheet Rubber Jointing and Rubber Insertion Jointing) |
- |
19250 |
|
5000 - -For tensile and Elongation at break
3000 - For accelerated ageing
3000 - For compression set
3500 - For resistance to bending
3500 - For adhesion testing
1250 - For hardness testing |
| 3.4(Tensile Strength and Elongation at Break) |
- |
19250 |
|
5000 - -For tensile and Elongation at break
3000 - For accelerated ageing
3000 - For compression set
3500 - For resistance to bending
3500 - For adhesion testing
1250 - For hardness testing |
| 3.5.1(Jointing to be Used for Joints Subjects to Water and Air Pressure) |
- |
19250 |
|
5000 - -For tensile and Elongation at break
3000 - For accelerated ageing
3000 - For compression set
3500 - For resistance to bending
3500 - For adhesion testing
1250 - For hardness testing |
| 3.5.2(Jointing to be Used for Joints Subjected to Steam Pressure) |
- |
19250 |
|
5000 - -For tensile and Elongation at break
3000 - For accelerated ageing
3000 - For compression set
3500 - For resistance to bending
3500 - For adhesion testing
1250 - For hardness testing |
| 3.6.1(Jointing to be Used for Joints Subject to Water and Air Pressure) |
- |
19250 |
|
5000 - -For tensile and Elongation at break
3000 - For accelerated ageing
3000 - For compression set
3500 - For resistance to bending
3500 - For adhesion testing
1250 - For hardness testing |
| 3.6.2(Jointing to be Used for Joints Subjects to Steam Pressure) |
- |
19250 |
|
5000 - -For tensile and Elongation at break
3000 - For accelerated ageing
3000 - For compression set
3500 - For resistance to bending
3500 - For adhesion testing
1250 - For hardness testing |
| 3.7(Resistance to Bending) |
- |
19250 |
|
5000 - -For tensile and Elongation at break
3000 - For accelerated ageing
3000 - For compression set
3500 - For resistance to bending
3500 - For adhesion testing
1250 - For hardness testing |
| 3.8(Adhesive) |
- |
19250 |
|
5000 - -For tensile and Elongation at break
3000 - For accelerated ageing
3000 - For compression set
3500 - For resistance to bending
3500 - For adhesion testing
1250 - For hardness testing |
| 3.9(Hardness) |
- |
19250.03 |
|
5000 - -For tensile and Elongation at break
3000 - For accelerated ageing
3000 - For compression set
3500 - For resistance to bending
3500 - For adhesion testing
1250 - For hardness testing |
| 4(Marking and Packing) |
- |
19250 |
|
5000 - -For tensile and Elongation at break
3000 - For accelerated ageing
3000 - For compression set
3500 - For resistance to bending
3500 - For adhesion testing
1250 - For hardness testing |
| Cl- 3.2.2.2(Outer layer thickness) |
- |
19250 |
|
5000 - -For tensile and Elongation at break
3000 - For accelerated ageing
3000 - For compression set
3500 - For resistance to bending
3500 - For adhesion testing
1250 - For hardness testing |
| (clause 4.2)(Construction and Workmanship) |
- |
19250 |
|
5000 - -For tensile and Elongation at break
3000 - For accelerated ageing
3000 - For compression set
3500 - For resistance to bending
3500 - For adhesion testing
1250 - For hardness testing |
| (clause 4.4)(Tensile Strength and Elongation at Break) |
- |
5000 |
|
For complete tensile and elongation testing |
| (clause 4.5)(Accelerated Ageing) |
- |
3000 |
|
For complete accelerated ageing test |
| (clause 4.6)(Compression Set) |
- |
3000 |
|
For complete compression set |
| (clause 4.7)(Resistance to Bending) |
- |
3500 |
|
For complete resistance to bending |
| (clause 4.8)(Adhesion) |
- |
3500 |
|
For complete adhesion testing |
| (clause 4.9)(Hardness) |
- |
1250 |
|
For complete hardness testing |
| (clause 4.2)(Construction and Workmanship) |
- |
19250 |
|
5000 - -For tensile and Elongation at break
3000 - For accelerated ageing
3000 - For compression set
3500 - For resistance to bending
3500 - For adhesion testing
1250 - For hardness testing |
| (clause 4.4)(Tensile Strength and Elongation at Break) |
- |
5000 |
|
For complete tensile and elongation testing |
| (clause 4.5)(Accelerated Ageing) |
- |
3000 |
|
For complete accelerated ageing test |
| (clause 4.6)(Compression Set) |
- |
3000 |
|
For complete compression set |
| (clause 4.7)(Resistance to Bending) |
- |
3500 |
|
For complete resistance to bending |
| (clause 4.8)(Adhesion) |
- |
3500 |
|
For complete adhesion testing |
| (clause 4.9)(Hardness) |
- |
1250 |
|
For complete hardness testing |
| (clause 4.2)(Construction and Workmanship) |
- |
- |
|
- |
| (clause 4.4)(Tensile Strength and Elongation at Break) |
- |
- |
|
- |
| (clause 4.5)(Accelerated Ageing) |
- |
- |
|
- |
| (clause 4.6)(Compression Set) |
- |
- |
|
- |
| (clause 4.7)(Resistance to Bending) |
- |
- |
|
- |
| (clause 4.8)(Adhesion) |
- |
- |
|
- |
| (clause 4.9)(Hardness) |
- |
- |
|
- |
|
- |
- Included w.e.f.11.08.2025 |
| 6263 |
QA TESTING LABORATORIES PRIVATE LIMITED, NOIDA
| 8169906
| IS 15658 (2021) |
Concrete Paving Blocks - Specification ( First Revision ) |
- |
6500 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Clause 7.3 & 9.1.4, Table 3, SI No. (v) b)(Average Flexural strength ) |
- |
200 |
|
Testing facility available |
| Clause 7.3 & 9.1.4, Table 3, SI No. (v) a)(Indivdual Flexural strength (i)) |
- |
300 |
|
Testing facility available |
| Clause 7.3 & 9.1.4, Table 3, SI No. (iv) b)(Average Tensile splitting strength ) |
- |
300 |
|
Testing facility available |
| Clause 7.3 & 9.1.4, Table 3, SI No. (iv) a)(Indivdual Tensile splitting strength (i)) |
- |
300 |
|
Testing facility available |
| Clause 7.3 & 9.1.4, Table 3, SI No. (iii) b) ii)(Wet Abrasion resistance (Average of three test specimens)) |
- |
300 |
|
Testing facility available |
| Clause 7.3 & 9.1.4, Table 3, SI No. (iii) b) i)( Indivdual Wet Abrasion Resistance ) |
- |
300 |
|
Testing facility available |
| Clause 7.3 & 9.1.4, Table 3, SI No. (iii) a) ii)(Dry Abrasion resistance (Average of three test specimens)) |
- |
300 |
|
Testing facility available |
| Clause 7.3 & 9.1.4, Table 3, SI No. (iii) a) i)( Indivdual Dry Abrasion Resistance ) |
- |
300 |
|
Testing facility available |
| Clause 7.3 & 9.1.4, Table 3, SI No. (ii) b)(Compressive strength (Average of eight test specimens)) |
- |
300 |
|
Testing facility available |
| Clause 7.3 & 9.1.4, Table 3, SI No. (ii) a)(Indivdual Compressive strength (i)) |
- |
300 |
|
Testing facility available |
| Clause 7.3 & 9.1.4, Table 3, SI No. (i) b)(Water absorption (Average of three test specimens)) |
- |
300 |
|
Testing facility available |
| Clause 7.2 & 9.1.3, Table 2, SI No. (ix)(Deviation from squareness) |
- |
300 |
|
Testing facility available |
| Clause 7.2 & 9.1.3, Table 2, SI No. (viii)(Indivdual Ratio of wearing face area and Plan area (Asw/Asp)) |
- |
300 |
|
Testing facility available |
| Clause 7.2 & 9.1.3, Table 2, SI No. (viii)(Ratio of wearing face area and Plan area (Asw/Asp)) |
- |
300 |
|
Testing facility available |
| Clause 7.2 & 9.1.3, Table 2, SI No. (vii)(Plan Area (Asp)) |
- |
300 |
|
Testing facility available |
| Clause 7.2 & 9.1.3, Table 2, SI No. (vi)(Thickness of wearing Layer) |
- |
300 |
|
Testing facility available |
| Clause 7.2, Table No. 2, SI No. (iii)
(Thickness, Th) |
- |
300 |
|
Testing facility available |
| Clause 7.2, Table No. 2, SI No. (ii)
(Length, L) |
- |
300 |
|
Testing facility available |
| Clause 7.2, Table No. 2, SI No. (i)
(Width, W) |
- |
300 |
|
Testing facility available |
| Clause 7.2, Table No. 2, SI No. (iv)
(Aspect Ratio, L/Th) |
- |
300 |
|
Testing facility available |
| Clause 7.2 & 9.1.3, Table 2, SI No. (v)(Arris/chamfer, Depth) |
- |
300 |
|
Testing facility available |
| Clause 7.2 & 9.1.3, Table 2, SI No. (v)(Arris/chamfer, Width) |
- |
300 |
|
Testing facility available |
| Clause 7.3 & 9.1.4, Table 3, SI No. (v) b)(Average Flexural strength ) |
- |
300 |
|
Testing facility available |
| Clause 7.3 & 9.1.4, Table 3, SI No. (v) a)(Indivdual Flexural strength (i)) |
- |
300 |
|
Testing facility available |
| Clause 7.3 & 9.1.4, Table 3, SI No. (iv) b)(Average Tensile splitting strength ) |
- |
300 |
|
Testing facility available |
| Clause 7.3 & 9.1.4, Table 3, SI No. (iv) a)(Indivdual Tensile splitting strength (i)) |
- |
300 |
|
Testing facility available |
| Clause 7.3 & 9.1.4, Table 3, SI No. (iii) b) ii)(Wet Abrasion resistance (Average of three test specimens)) |
- |
300 |
|
Testing facility available |
| Clause 7.3 & 9.1.4, Table 3, SI No. (iii) b) i)( Indivdual Wet Abrasion Resistance ) |
- |
300 |
|
Testing facility available |
| Clause 7.3 & 9.1.4, Table 3, SI No. (iii) a) ii)(Dry Abrasion resistance (Average of three test specimens)) |
- |
300 |
|
Testing facility available |
| Clause 7.3 & 9.1.4, Table 3, SI No. (iii) a) i)( Indivdual Dry Abrasion Resistance ) |
- |
300 |
|
Testing facility available |
| Clause 7.3 & 9.1.4, Table 3, SI No. (ii) b)(Compressive strength (Average of eight test specimens)) |
- |
300 |
|
Testing facility available |
| Clause 7.3 & 9.1.4, Table 3, SI No. (ii) a)(Indivdual Compressive strength (i)) |
- |
300 |
|
Testing facility available |
| Clause 7.3 & 9.1.4, Table 3, SI No. (i) b)(Water absorption (Average of three test specimens)) |
- |
300 |
|
Testing facility available |
| Clause 7.2 & 9.1.3, Table 2, SI No. (ix)(Deviation from squareness) |
- |
300 |
|
Testing facility available |
| Clause 7.2 & 9.1.3, Table 2, SI No. (viii)(Indivdual Ratio of wearing face area and Plan area (Asw/Asp)) |
- |
300 |
|
Testing facility available |
| Clause 7.2 & 9.1.3, Table 2, SI No. (viii)(Ratio of wearing face area and Plan area (Asw/Asp)) |
- |
300 |
|
Testing facility available |
| Clause 7.2 & 9.1.3, Table 2, SI No. (vii)(Plan Area (Asp)) |
- |
300 |
|
Testing facility available |
| Clause 7.2 & 9.1.3, Table 2, SI No. (vi)(Thickness of wearing Layer) |
- |
300 |
|
Testing facility available |
| Clause 7.2, Table No. 2, SI No. (iii)
(Thickness, Th) |
- |
300 |
|
Testing facility available |
| Clause 7.2, Table No. 2, SI No. (ii)
(Length, L) |
- |
300 |
|
Testing facility available |
| Clause 7.2, Table No. 2, SI No. (i)
(Width, W) |
- |
300 |
|
Testing facility available |
| Clause 7.2, Table No. 2, SI No. (iv)
(Aspect Ratio, L/Th) |
- |
300 |
|
Testing facility available |
| Clause 7.2 & 9.1.3, Table 2, SI No. (v)(Arris/chamfer, Depth) |
- |
300 |
|
Testing facility available |
| Clause 7.2 & 9.1.3, Table 2, SI No. (v)(Arris/chamfer, Width) |
- |
300 |
|
Testing facility available |
| 5.4(Coarse and Fine
Aggregates) |
- |
300 |
|
Testing facility available |
| Clause 7.3 & 9.1.4, Table 3, SI No. (v) b)(Average Flexural strength ) |
- |
300 |
|
- |
| Clause 7.3 & 9.1.4, Table 3, SI No. (v) a)(Indivdual Flexural strength (i)) |
- |
300 |
|
- |
| Clause 7.3 & 9.1.4, Table 3, SI No. (iv) b)(Average Tensile splitting strength ) |
- |
300 |
|
- |
| Clause 7.3 & 9.1.4, Table 3, SI No. (iv) a)(Indivdual Tensile splitting strength (i)) |
- |
300 |
|
- |
| Clause 7.3 & 9.1.4, Table 3, SI No. (iii) b) ii)(Wet Abrasion resistance (Average of three test specimens)) |
- |
300 |
|
- |
| Clause 7.3 & 9.1.4, Table 3, SI No. (iii) b) i)( Indivdual Wet Abrasion Resistance ) |
- |
300 |
|
- |
| Clause 7.3 & 9.1.4, Table 3, SI No. (iii) a) ii)(Dry Abrasion resistance (Average of three test specimens)) |
- |
300 |
|
- |
| Clause 7.3 & 9.1.4, Table 3, SI No. (iii) a) i)( Indivdual Dry Abrasion Resistance ) |
- |
300 |
|
- |
| Clause 7.3 & 9.1.4, Table 3, SI No. (ii) b)(Compressive strength (Average of eight test specimens)) |
- |
300 |
|
- |
| Clause 7.3 & 9.1.4, Table 3, SI No. (ii) a)(Indivdual Compressive strength (i)) |
- |
300 |
|
- |
| Clause 7.3 & 9.1.4, Table 3, SI No. (i) b)(Water absorption (Average of three test specimens)) |
- |
300 |
|
- |
| Clause 7.2 & 9.1.3, Table 2, SI No. (ix)(Deviation from squareness) |
- |
300 |
|
- |
| Clause 7.2 & 9.1.3, Table 2, SI No. (viii)(Indivdual Ratio of wearing face area and Plan area (Asw/Asp)) |
- |
300 |
|
- |
| Clause 7.2 & 9.1.3, Table 2, SI No. (viii)(Ratio of wearing face area and Plan area (Asw/Asp)) |
- |
300 |
|
- |
| Clause 7.2 & 9.1.3, Table 2, SI No. (vii)(Plan Area (Asp)) |
- |
300 |
|
- |
| Clause 7.2 & 9.1.3, Table 2, SI No. (vi)(Thickness of wearing Layer) |
- |
300 |
|
- |
| Clause 7.2, Table No. 2, SI No. (iii)
(Thickness, Th) |
- |
300 |
|
- |
| Clause 7.2, Table No. 2, SI No. (ii)
(Length, L) |
- |
300 |
|
- |
| Clause 7.2, Table No. 2, SI No. (i)
(Width, W) |
- |
300 |
|
- |
| Clause 7.2, Table No. 2, SI No. (iv)
(Aspect Ratio, L/Th) |
- |
300 |
|
- |
| Clause 7.2 & 9.1.3, Table 2, SI No. (v)(Arris/chamfer, Depth) |
- |
300 |
|
- |
| Clause 7.2 & 9.1.3, Table 2, SI No. (v)(Arris/chamfer, Width) |
- |
300 |
|
- |
| 5.4(Coarse and Fine
Aggregates) |
- |
300 |
|
. |
|
05 Apr, 2028 |
- Included w.e.f 04.07.2025
Except freeze thaw durability |
| 6264 |
Shri Krishna Test House
| 8122336
| IS 18573 (2024) |
Cold formed welded carbon steel square and rectangular hollow sections for mechanical, general engineering and decorative purposes � Specification |
ALL GRADES |
17000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Clause. 3.0(Types) |
- |
17000 |
|
- |
| Clause.4.0(Carbon) |
- |
17000 |
|
- |
| Clause.4.0(Sulphur) |
- |
17000 |
|
- |
| Clause.4.0(Sulphur) |
- |
17000 |
|
- |
| Clause.4.0(Phosphorus) |
- |
17000 |
|
- |
| Clause.4.0(Silicon) |
- |
17000 |
|
- |
| Clause.4.0(Manganese) |
- |
17000 |
|
- |
| Clause.5.0(Supply of Material) |
- |
17000 |
|
- |
| Clause.5.0(Supply of Material) |
- |
17000 |
|
- |
| Clause.6.0(Workmanship) |
- |
17000 |
|
- |
| Clause.7.0(Straightness) |
- |
17000 |
|
- |
| Clause.8.0(Basis of Calculation) |
- |
17000 |
|
- |
| Clause.9.0(Length) |
- |
17000 |
|
- |
| Clause.10.0(Dimensions and properties) |
- |
17000 |
|
- |
| Clause.10.0(Dimensions and properties) |
- |
17000 |
|
- |
| Clause.11.0(General) |
- |
17000 |
|
- |
| Clause.11.0(Outside Dimension) |
- |
17000 |
|
- |
| Clause.11.0(Thickness) |
- |
17000 |
|
- |
| Clause.11.0(Thickness) |
- |
17000 |
|
- |
| Clause.11.0(Concavity and Convexity) |
- |
17000 |
|
- |
| Clause.11.0(Squareness of Sides) |
- |
17000 |
|
- |
| Clause.11.0(External Corner Radiius) |
- |
17000 |
|
- |
| Clause.11.0(Straightness and twist) |
- |
17000 |
|
- |
| Clause.12.0(Dimension Tolerances) |
- |
17000 |
|
- |
| Clause.12.0(Dimension Tolerances) |
- |
17000 |
|
- |
| Clause.13.0(Surface Protection) |
- |
17000 |
|
- |
| Clause.14.0(Testing) |
- |
17000 |
|
- |
| Clause.15.0(Tensile test) |
- |
17000 |
|
- |
| Clause.15.0(Yield strength) |
- |
17000 |
|
- |
| Clause.15.0(Elognation Percent) |
- |
17000 |
|
- |
| Clause.18.0(Marking) |
- |
17000 |
|
- |
| 6(Workmanship) |
- |
17000 |
|
- |
| 10(Dimensions and Properties) |
- |
17000 |
|
- |
| 11(Measurement of Shape and Size) |
- |
17000 |
|
- |
| 12(Dimensions and Tolerances) |
- |
17000 |
|
- |
| 13(Surface Protection) |
- |
17000 |
|
- |
| 15(Tensile Test) |
- |
17000 |
|
- |
|
05 Oct, 2028 |
- Included w.e.f.30.04.2025 |
| 6265 |
DELHI TEST HOUSE (50) KUNDLI SONIPAT
| 9127026
| IS 16543 (2016) |
All glass evacuated solar collector tubes - Specification |
-- |
15000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 7.3 (Annex - A)(Stagnation Performance Parameter Test) |
- |
1000 |
|
- |
| 7.4 (Annex - B)(Stagnation Solar Irradiance Test) |
- |
1500 |
|
- |
| 7.5 (Annex - C)(Average Heat Loss Coefficient Test) |
- |
1500 |
|
- |
| 7.6 (Annex - D-1)(Air Pressure Test Inside the Vacuum Jacket) |
- |
1500 |
|
- |
| 7.6 (Annex - D-2)(Vacuum Quality Test) |
- |
1500 |
|
- |
| 7.7 (Annex - E)(Resistance to Thermal Shock Test) |
- |
2000 |
|
- |
| 7.8 (Annex - F)(Resistance to Impact Test) |
- |
1000 |
|
- |
| 7.9 (Annex - G)(Resistance to Internal Pressure Test) |
- |
1500 |
|
- |
| 7.10 (Annex - H-2)(Absorptivity Test of Selective Coating) |
- |
1000 |
|
- |
| 7.10 (Annex - H-3)(Emissivity Test of selective coating) |
- |
1000 |
|
- |
| 7.1(Dimensions) |
- |
500 |
|
- |
| 7.2(Appearance and Dimensions) |
- |
500 |
|
- |
| 5(GENERAL REQUIREMENTS) |
- |
500 |
|
- |
|
23 Jun, 2028 |
- Included w.e.f.30.04.2025 |
| 6266 |
Gravitas Laboratories Private Limited, Greater Noida
| 8182606
| IS 7904 (2018) |
High carbon steel wire rods - Specification (Second Revision) |
- |
10000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Table-1,(Clauses 5.1 and 7.2)(S+P) |
- |
500 |
|
- |
| Table-1,(Clauses 5.1 and 7.2)(Nitrogen) |
- |
500 |
|
- |
| Table-1,(Clauses 5.1 and 7.2)(Titanium) |
- |
500 |
|
- |
| Table-1,(Clauses 5.1 and 7.2)(Vanadium) |
- |
500 |
|
- |
| Table-1,(Clauses 5.1 and 7.2)(Boron) |
- |
500 |
|
- |
| Table-1,(Clauses 5.1 and 7.2)(Copper) |
- |
500 |
|
- |
| Table-1,(Clauses 5.1 and 7.2)(Molybdenum) |
- |
500 |
|
- |
| Table-1,(Clauses 5.1 and 7.2)(Nickel) |
- |
500 |
|
- |
| Table-1,(Clauses 5.1 and 7.2)(Chromium) |
- |
500 |
|
- |
| Table-1,(Clauses 5.1 and 7.2)(Aluminium) |
- |
500 |
|
- |
| Table-1,(Clauses 5.1 and 7.2)(Silicon) |
- |
500 |
|
- |
| Table-1,(Clauses 5.1 and 7.2)(Manganese) |
- |
500 |
|
- |
| Table-1,(Clauses 5.1 and 7.2)(Phosphorous) |
- |
500 |
|
- |
| Table-1,(Clauses 5.1 and 7.2)(Sulphor) |
- |
500 |
|
- |
| Table-1,(Clauses 5.1 and 7.2)(Carbon) |
- |
500 |
|
- |
| Cl 9 (Dimensions & tolerances)() |
- |
500 |
|
- |
| 9(Dimesion (Diameter)) |
- |
500 |
|
- |
| 9(Dimesion (Out of Roundness)) |
- |
500 |
|
- |
| 10(Mechanical Properties (Tensile strength)) |
- |
1500 |
|
- |
| 10(Mechanical Properties (Reduction in Area)) |
- |
800 |
|
- |
| 12(Surface Defects) |
- |
500 |
|
- |
| 13(Decarburization Test) |
- |
1500 |
|
- |
| 14(Non-metallic Inclusions (Type A (Sulphide Type) (Thin, worse)) |
- |
1500 |
|
- |
| 14(Type B (Alumina Type) (Thin, worse)) |
- |
600 |
|
- |
| 14(Type C (Silicate Type) (Thin, worse)) |
- |
600 |
|
- |
| 14(Type D( Globular Oxide Type ) (Thin, worse)) |
- |
600 |
|
- |
| 14(Non-metallic Inclusions (Type A (Sulphide Type) (Thin, Mean)) |
- |
600 |
|
- |
| 14(Type B (Alumina Type) (Thin, Mean)) |
- |
600 |
|
- |
| 14(Type C (Silicate Type) (Thin, Mean)) |
- |
600 |
|
- |
| 14(Type D( Globular Oxide Type ) (Thin, Mean)) |
- |
600 |
|
- |
| 14(Non-metallic Inclusions (Type A (Sulphide Type) (Thick, worse)) |
- |
600 |
|
- |
| 14(Type B (Alumina Type) (Thick, worse)) |
- |
600 |
|
- |
| 14(Type C (Silicate Type) (Thick, worse)) |
- |
600 |
|
- |
| 14(Type D( Globular Oxide Type ) (Thick, worse)) |
- |
600 |
|
- |
| 14(Non-metallic Inclusions (Type A (Sulphide Type) (Thick, Mean)) |
- |
600 |
|
- |
| 14(Type B (Alumina Type) (Thick, Mean)) |
- |
600 |
|
- |
| 14(Type C (Silicate Type) (Thick, Mean)) |
- |
600 |
|
- |
| 14(Type D( Globular Oxide Type ) (Thick, Mean)) |
- |
600 |
|
- |
| 15(Microstructure) |
- |
600 |
|
- |
| 16(Axial Segregation (Optional)) |
- |
600 |
|
- |
| TABLE 1 NOTE 1(Any Validated test method) |
- |
600 |
|
- |
| TABLE 1 NOTE 1(By Calculation) |
- |
600 |
|
- |
| TABLE 1 NOTE 6() |
- |
600 |
|
- |
| TABLE 1 NOTE 1(Any Validated test method) |
- |
600 |
|
- |
| TABLE 1 NOTE 1(By Calculation) |
- |
600 |
|
- |
| TABLE 1 NOTE 6(Tramp Element (Cr+ Ni+ Mo+ Cu)) |
- |
600 |
|
- |
| TABLE 1 NOTE 1(Any Validated test method) |
- |
600 |
|
- |
| TABLE 1 NOTE 1(By Calculation) |
- |
600 |
|
- |
| TABLE 1 NOTE 6() |
- |
600 |
|
- |
| TABLE 1 NOTE 1(Niobium) |
- |
600 |
|
- |
| TABLE 1 NOTE 1(Micro Alloy Element (Nb+V+Ti)) |
- |
600 |
|
- |
| TABLE 1 NOTE 6(Tramp Element (Cr+ Ni+ Mo+ Cu)) |
- |
600 |
|
- |
| TABLE 1 NOTE 6(Tramp Element (Cr+ Ni+ Mo+ Cu)) |
- |
600 |
|
- |
| Cl 9 (Dimensions & tolerances)() |
- |
0 |
|
- |
| 9(Dimesion (Diameter)) |
- |
0 |
|
- |
| 9(Dimesion (Out of Roundness)) |
- |
0 |
|
- |
| 10(Mechanical Properties (Tensile strength)) |
- |
0 |
|
- |
| 10(Mechanical Properties (Reduction in Area)) |
- |
0 |
|
- |
| 12(Surface Defects) |
- |
0 |
|
- |
| 13(Decarburization Test) |
- |
0 |
|
- |
| 14(Non-metallic Inclusions (Type A (Sulphide Type) (Thin, worse)) |
- |
0 |
|
- |
| 14(Type B (Alumina Type) (Thin, worse)) |
- |
0 |
|
- |
| 14(Type C (Silicate Type) (Thin, worse)) |
- |
0 |
|
- |
| 14(Type D( Globular Oxide Type ) (Thin, worse)) |
- |
0 |
|
- |
| 14(Non-metallic Inclusions (Type A (Sulphide Type) (Thin, Mean)) |
- |
0 |
|
- |
| 14(Type B (Alumina Type) (Thin, Mean)) |
- |
0 |
|
- |
| 14(Type C (Silicate Type) (Thin, Mean)) |
- |
0 |
|
- |
| 14(Type D( Globular Oxide Type ) (Thin, Mean)) |
- |
0 |
|
- |
| 14(Non-metallic Inclusions (Type A (Sulphide Type) (Thick, worse)) |
- |
0 |
|
- |
| 14(Type B (Alumina Type) (Thick, worse)) |
- |
0 |
|
- |
| 14(Type C (Silicate Type) (Thick, worse)) |
- |
0 |
|
- |
| 14(Type D( Globular Oxide Type ) (Thick, worse)) |
- |
0 |
|
- |
| 14(Non-metallic Inclusions (Type A (Sulphide Type) (Thick, Mean)) |
- |
0 |
|
- |
| 14(Type B (Alumina Type) (Thick, Mean)) |
- |
0 |
|
- |
| 14(Type C (Silicate Type) (Thick, Mean)) |
- |
0 |
|
- |
| 14(Type D( Globular Oxide Type ) (Thick, Mean)) |
- |
0 |
|
- |
| 15(Microstructure) |
- |
0 |
|
- |
| 16(Axial Segregation (Optional)) |
- |
0 |
|
- |
| TABLE 1 NOTE 1(Any Validated test method) |
- |
0 |
|
- |
| TABLE 1 NOTE 1(By Calculation) |
- |
0 |
|
- |
| TABLE 1 NOTE 6() |
- |
0 |
|
- |
| TABLE 1 NOTE 1(Any Validated test method) |
- |
0 |
|
- |
| TABLE 1 NOTE 1(By Calculation) |
- |
0 |
|
- |
| TABLE 1 NOTE 6(Tramp Element (Cr+ Ni+ Mo+ Cu)) |
- |
0 |
|
- |
| TABLE 1 NOTE 1(Any Validated test method) |
- |
0 |
|
- |
| TABLE 1 NOTE 1(By Calculation) |
- |
0 |
|
- |
| TABLE 1 NOTE 6() |
- |
0 |
|
- |
| TABLE 1 NOTE 1(Niobium) |
- |
0 |
|
- |
| TABLE 1 NOTE 1(Micro Alloy Element (Nb+V+Ti)) |
- |
0 |
|
- |
| TABLE 1 NOTE 6(Tramp Element (Cr+ Ni+ Mo+ Cu)) |
- |
0 |
|
- |
| TABLE 1 NOTE 6(Tramp Element (Cr+ Ni+ Mo+ Cu)) |
- |
0 |
|
- |
| Cl 9 (Dimensions & tolerances)() |
- |
- |
|
- |
| 9(Dimesion (Diameter)) |
- |
- |
|
- |
| 9(Dimesion (Out of Roundness)) |
- |
- |
|
- |
| 10(Mechanical Properties (Tensile strength)) |
- |
- |
|
- |
| 10(Mechanical Properties (Reduction in Area)) |
- |
- |
|
- |
| 12(Surface Defects) |
- |
- |
|
- |
| 13(Decarburization Test) |
- |
- |
|
- |
| 14(Non-metallic Inclusions (Type A (Sulphide Type) (Thin, worse)) |
- |
- |
|
- |
| 14(Type B (Alumina Type) (Thin, worse)) |
- |
- |
|
- |
| 14(Type C (Silicate Type) (Thin, worse)) |
- |
- |
|
- |
| 14(Type D( Globular Oxide Type ) (Thin, worse)) |
- |
- |
|
- |
| 14(Non-metallic Inclusions (Type A (Sulphide Type) (Thin, Mean)) |
- |
- |
|
- |
| 14(Type B (Alumina Type) (Thin, Mean)) |
- |
- |
|
- |
| 14(Type C (Silicate Type) (Thin, Mean)) |
- |
- |
|
- |
| 14(Type D( Globular Oxide Type ) (Thin, Mean)) |
- |
- |
|
- |
| 14(Non-metallic Inclusions (Type A (Sulphide Type) (Thick, worse)) |
- |
- |
|
- |
| 14(Type B (Alumina Type) (Thick, worse)) |
- |
- |
|
- |
| 14(Type C (Silicate Type) (Thick, worse)) |
- |
- |
|
- |
| 14(Type D( Globular Oxide Type ) (Thick, worse)) |
- |
- |
|
- |
| 14(Non-metallic Inclusions (Type A (Sulphide Type) (Thick, Mean)) |
- |
- |
|
- |
| 14(Type B (Alumina Type) (Thick, Mean)) |
- |
- |
|
- |
| 14(Type C (Silicate Type) (Thick, Mean)) |
- |
- |
|
- |
| 14(Type D( Globular Oxide Type ) (Thick, Mean)) |
- |
- |
|
- |
| 15(Microstructure) |
- |
- |
|
- |
| 16(Axial Segregation (Optional)) |
- |
- |
|
- |
| TABLE 1 NOTE 1(Any Validated test method) |
- |
- |
|
- |
| TABLE 1 NOTE 1(By Calculation) |
- |
- |
|
- |
| TABLE 1 NOTE 6() |
- |
- |
|
- |
| TABLE 1 NOTE 1(Any Validated test method) |
- |
- |
|
- |
| TABLE 1 NOTE 1(By Calculation) |
- |
- |
|
- |
| TABLE 1 NOTE 6(Tramp Element (Cr+ Ni+ Mo+ Cu)) |
- |
- |
|
- |
| TABLE 1 NOTE 1(Any Validated test method) |
- |
- |
|
- |
| TABLE 1 NOTE 1(By Calculation) |
- |
- |
|
- |
| TABLE 1 NOTE 6() |
- |
- |
|
- |
| TABLE 1 NOTE 1(Niobium) |
- |
- |
|
- |
| TABLE 1 NOTE 1(Micro Alloy Element (Nb+V+Ti)) |
- |
- |
|
- |
| TABLE 1 NOTE 6(Tramp Element (Cr+ Ni+ Mo+ Cu)) |
- |
- |
|
- |
| TABLE 1 NOTE 6(Tramp Element (Cr+ Ni+ Mo+ Cu)) |
- |
- |
|
- |
|
- |
- Included w.e.f 02.06.2025 |
| 6267 |
Gravitas Laboratories Private Limited, Greater Noida
| 8182606
| IS 7902 (2001) |
Aluminium alloy forging stock and forgings (Alloy 24345) for aerospace applications - Specification (First Revision) |
All grades |
20000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 6(FREEDOM FROM DEFECTS) |
- |
500 |
|
- |
| 7 table 1(CHEMICAL COMPOSITION) |
- |
2000 |
|
- |
| 10.1(Tensile Test) |
- |
1200 |
|
- |
| 10.2(Hardness) |
- |
1200 |
|
- |
| 11(DIMENSIONS AND TOLERANCES) |
- |
500 |
|
- |
| 13(RETEST) |
- |
1500 |
|
- |
| Cl.7(Copper - IS 504 and its parts or any other intrumental/chemical methods) |
- |
500 |
|
- |
| Cl.7(Magnesium - IS 504 and its parts or any other intrumental/chemical methods) |
- |
500 |
|
- |
| Cl.7(Manganese - IS 504 and its parts or any other intrumental/chemical methods) |
- |
500 |
|
- |
| Cl.7(Titanium - IS 504 and its parts or any other intrumental/chemical methods) |
- |
500 |
|
- |
| Cl.7(Titanium+Zirconium - IS 504 and its parts or any other intrumental/chemical methods) |
- |
500 |
|
- |
| Cl.7(Iron - IS 504 and its parts or any other intrumental/chemical methods) |
- |
500 |
|
- |
| Cl.7(Zinc - IS 504 and its parts or any other intrumental/chemical methods) |
- |
500 |
|
- |
| Cl.7(Tin - IS 504 and its parts or any other intrumental/chemical methods) |
- |
500 |
|
- |
| Cl.7(Chromium - IS 504 and its parts or any other intrumental/chemical methods) |
- |
500 |
|
- |
| Cl.7(Nickel - IS 504 and its parts or any other intrumental/chemical methods) |
- |
500 |
|
- |
| Cl.7(Lead - IS 504 and its parts or any other intrumental/chemical methods) |
- |
500 |
|
- |
| Cl.7(Copper - IS 504 and its parts or any other intrumental/chemical methods) |
- |
500 |
|
- |
| Cl.7(Magnesium - IS 504 and its parts or any other intrumental/chemical methods) |
- |
500 |
|
- |
| Cl.7(Silicon - IS 504 and its parts or any other intrumental/chemical methods) |
- |
500 |
|
- |
| Cl.7(Manganese - IS 504 and its parts or any other intrumental/chemical methods) |
- |
500 |
|
- |
| Cl.7(Titanium - IS 504 and its parts or any other intrumental/chemical methods) |
- |
500 |
|
- |
| Cl.7(Titanium+Zirconium - IS 504 and its parts or any other intrumental/chemical methods) |
- |
500 |
|
- |
| Cl.7(Iron - IS 504 and its parts or any other intrumental/chemical methods) |
- |
500 |
|
- |
| Cl.7(Zinc - IS 504 and its parts or any other intrumental/chemical methods) |
- |
500 |
|
- |
| Cl.7(Tin - IS 504 and its parts or any other intrumental/chemical methods) |
- |
500 |
|
- |
| Cl.7(Chromium - IS 504 and its parts or any other intrumental/chemical methods) |
- |
500 |
|
- |
| Cl.7(Nickel - IS 504 and its parts or any other intrumental/chemical methods) |
- |
500 |
|
- |
| Cl.7(Nickel - IS 504 and its parts or any other intrumental/chemical methods) |
- |
500 |
|
- |
| 6(Freedom from defect) |
- |
500 |
|
- |
| 10.1(Tensile strength) |
- |
1200 |
|
- |
| 12.1(Inspection and Testing) |
- |
1500 |
|
- |
| 12.2.1(Dye Penetrant Test) |
- |
560 |
|
- |
| 12.2.2(Macro and Micro-Examination) |
- |
1500 |
|
- |
| 10.1(0.2 % proof stress) |
- |
1500 |
|
- |
| 10.1(Elongation) |
- |
500 |
|
- |
| 10.2(Hardness Test) |
- |
1200 |
|
- |
| 11(Dimensions and Tolerance) |
- |
500 |
|
- |
| 6(Freedom from defect) |
- |
500 |
|
- |
| 10.1(Tensile strength) |
- |
1500 |
|
- |
| 10.1(0.2 % proof stress) |
- |
1500 |
|
- |
| 10.1(Elongation) |
- |
500 |
|
- |
| 10.2(Hardness Test) |
- |
1500 |
|
- |
| 11(DIMENSIONS AND TOLEF&WtCES) |
- |
500 |
|
- |
|
- |
- Included w.e.f 02.06.2025
Exclusion: Cl 12.2.1 Ultrasonic test |
| 6268 |
EKO PRO ENGINEERS PVT LTD
| 8188216
| IS 14203 (2023) |
FIRE RESISTING RECORD PROTECTION CABINETS SPECIFICATION Second Revision of IS 14203 |
- |
250000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 3 and 6 (Table 1)(Nominal Sizes - Height) |
- |
2000 |
|
- |
| 3 and 6 (Table 1)(Nominal Sizes - Width) |
- |
2000 |
|
- |
| 3 and 6 (Table 1)(Nominal Sizes - Depth) |
- |
2000 |
|
- |
| 3 and 6 (Table 1)(Height of Pedestal) |
- |
2000 |
|
- |
| 7(Designation) |
- |
2000 |
|
- |
| 8.1(Cabinet Construction) |
- |
2000 |
|
- |
| 8.2(Locking Mechanism) |
- |
2000 |
|
- |
| 8.3(Locks) |
- |
2000 |
|
- |
| 8.4(Handles) |
- |
2000 |
|
- |
| 9(Internal Fixtures) |
- |
2000 |
|
- |
| 10.1(Minimum overall thinckness of coating) |
- |
2000 |
|
- |
| 10.2(Cross Hatch Test) |
- |
10000 |
|
- |
| 11, Annex-B, 3.1(Fire Endurance Test) |
- |
103000 |
|
- |
| 11, Annex-B, 3.2(Fire and Impact test) |
- |
115000 |
|
- |
|
19 Sep, 2028 |
- FR30, FR 60, FR 90, FR 120
(All type, all sizes) |
| 6269 |
Atmy Analytical Labs Private Limited (Unit-2), Greater Noida
| 8176106
| IS 4250 (2025) |
Electric Food-Mixers (Liquidizers and Grinders) and Centrifugal Juicers � Specification ( Second Revision ) |
All |
33000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl-4(General Requirements) |
- |
0 |
|
- |
| Cl-5(General Conditions for the tests) |
- |
0 |
|
- |
| Cl-6(Classification) |
- |
0 |
|
- |
| Cl-7(Marking) |
- |
0 |
|
- |
| Cl-8(Safety Requirements) |
- |
20000 |
|
- |
| Cl-9(Endurance fpr motor and base assembly) |
- |
14000 |
|
- |
| Cl-10.2("Grinding Coffee (for Machines that Have a
Dry Grinding Arrangement)") |
- |
0 |
|
Test charges included in the clause 10.5 |
| Cl-10.3(Whisking Egg Whites (for Machines that have Whisking Egg Arrangement)) |
- |
0 |
|
Test charges included in the clause 10.5 |
| Cl-10.4(Idli Batter) |
- |
0 |
|
Test charges included in the clause 10.5 |
| Cl-10.5(Operational Tests for Juicers) |
- |
7500 |
|
- |
| Cl-11(Temperature Withstand Test for Bowl) |
- |
4000 |
|
- |
| Cl-12.1(Test for Switches) |
- |
4000 |
|
- |
| Cl-13(Strength of Assembly) |
- |
3500 |
|
- |
| Cl-14.2, 14.3 Table-2 (i)(Protection against access to live parts) |
- |
0 |
|
- |
| Cl-14.2, Table-2 (ii)(Power input and current) |
- |
0 |
|
- |
| Cl-14.2, 14.3 Table-2 (iii)(Leakage current and electric strength at operating temperature) |
- |
0 |
|
- |
| Cl-14.2, Table-2 (iv)(Moisture resistance) |
- |
0 |
|
- |
| Cl-14.2, Table-2 (v)(Leakage current and electric strength) |
- |
0 |
|
- |
| Cl-14.2, 14.3 Table-2 (vi)(Provision for earthing) |
- |
0 |
|
- |
| Cl-19.11.4.1(Electrostatic discharges) |
- |
0 |
|
- |
| Cl-19.11.4.2(Radiated fields) |
- |
0 |
|
- |
| Cl-19.11.4.3(Fast transient bursts) |
- |
0 |
|
- |
| Cl-19.11.4.4(Surge immunity test) |
- |
0 |
|
- |
| Cl-19.11.4.5(Immunity to conducted discharges) |
- |
0 |
|
- |
| Cl-19.11.4.6(Class 3 Voltage dips and interruptions) |
- |
0 |
|
- |
| Cl-19.11.4.7(Harmonics) |
- |
4000 |
|
- |
| Cl-4(General Requirements) |
- |
0 |
|
- |
| Cl-5(General Conditions for the tests) |
- |
0 |
|
- |
| Cl-6(Classification) |
- |
0 |
|
- |
| Cl-7(Marking) |
- |
0 |
|
- |
| Cl-8(Safety Requirements) |
- |
0 |
|
- |
| Cl-9(Endurance fpr motor and base assembly) |
- |
0 |
|
- |
| Cl-10.2("Grinding Coffee (for Machines that Have a
Dry Grinding Arrangement)") |
- |
0 |
|
- |
| Cl-10.3(Whisking Egg Whites (for Machines that have Whisking Egg Arrangement)) |
- |
0 |
|
- |
| Cl-10.4(Idli Batter) |
- |
0 |
|
- |
| Cl-10.5(Operational Tests for Juicers) |
- |
0 |
|
- |
| Cl-11(Temperature Withstand Test for Bowl) |
- |
0 |
|
- |
| Cl-12.1(Test for Switches) |
- |
0 |
|
- |
| Cl-13(Strength of Assembly) |
- |
0 |
|
- |
| Cl-14.2, 14.3 Table-2 (i)(Protection against access to live parts) |
- |
0 |
|
- |
| Cl-14.2, Table-2 (ii)(Power input and current) |
- |
0 |
|
- |
| Cl-14.2, 14.3 Table-2 (iii)(Leakage current and electric strength at operating temperature) |
- |
0 |
|
- |
| Cl-14.2, Table-2 (iv)(Moisture resistance) |
- |
0 |
|
- |
| Cl-14.2, Table-2 (v)(Leakage current and electric strength) |
- |
0 |
|
- |
| Cl-14.2, 14.3 Table-2 (vi)(Provision for earthing) |
- |
0 |
|
- |
| Cl-4(General Requirements) |
- |
0 |
|
- |
| Cl-5(General Conditions for the tests) |
- |
0 |
|
- |
| Cl-6(Classification) |
- |
0 |
|
- |
| Cl-7(Marking) |
- |
0 |
|
- |
| Cl-8(Safety Requirements) |
- |
0 |
|
- |
| Cl-9(Endurance fpr motor and base assembly) |
- |
0 |
|
- |
| Cl-10.2("Grinding Coffee (for Machines that Have a
Dry Grinding Arrangement)") |
- |
0 |
|
- |
| Cl-10.3(Whisking Egg Whites (for Machines that have Whisking Egg Arrangement)) |
- |
0 |
|
- |
| Cl-10.4(Idli Batter) |
- |
0 |
|
- |
| Cl-10.5(Operational Tests for Juicers) |
- |
0 |
|
- |
| Cl-11(Temperature Withstand Test for Bowl) |
- |
0 |
|
- |
| Cl-12.1(Test for Switches) |
- |
0 |
|
- |
| Cl-13(Strength of Assembly) |
- |
0 |
|
- |
| Cl-14.2, 14.3 Table-2 (i)(Protection against access to live parts) |
- |
0 |
|
- |
| Cl-14.2, Table-2 (ii)(Power input and current) |
- |
0 |
|
- |
| Cl-14.2, 14.3 Table-2 (iii)(Leakage current and electric strength at operating temperature) |
- |
0 |
|
- |
| Cl-14.2, Table-2 (iv)(Moisture resistance) |
- |
0 |
|
- |
| Cl-14.2, Table-2 (v)(Leakage current and electric strength) |
- |
0 |
|
- |
| Cl-14.2, 14.3 Table-2 (vi)(Provision for earthing) |
- |
0 |
|
- |
| Cl-19.11.4.7(Harmonics) |
- |
0 |
|
- |
| Cl-4(General Requirements) |
- |
0 |
|
- |
| Cl-5(General Conditions for the tests) |
- |
0 |
|
- |
| Cl-6(Classification) |
- |
0 |
|
- |
| Cl-7(Marking) |
- |
0 |
|
- |
| Cl-8(Safety Requirements) |
- |
0 |
|
- |
| Cl-9(Endurance fpr motor and base assembly) |
- |
0 |
|
- |
| Cl-10.2("Grinding Coffee (for Machines that Have a
Dry Grinding Arrangement)") |
- |
0 |
|
- |
| Cl-10.3(Whisking Egg Whites (for Machines that have Whisking Egg Arrangement)) |
- |
0 |
|
- |
| Cl-10.4(Idli Batter) |
- |
0 |
|
- |
| Cl-10.5(Operational Tests for Juicers) |
- |
0 |
|
- |
| Cl-11(Temperature Withstand Test for Bowl) |
- |
0 |
|
- |
| Cl-12.1(Test for Switches) |
- |
0 |
|
- |
| Cl-13(Strength of Assembly) |
- |
0 |
|
- |
| Cl-14.2, 14.3 Table-2 (i)(Protection against access to live parts) |
- |
0 |
|
- |
| Cl-14.2, Table-2 (ii)(Power input and current) |
- |
0 |
|
- |
| Cl-14.2, 14.3 Table-2 (iii)(Leakage current and electric strength at operating temperature) |
- |
0 |
|
- |
| Cl-14.2, Table-2 (iv)(Moisture resistance) |
- |
0 |
|
- |
| Cl-14.2, Table-2 (v)(Leakage current and electric strength) |
- |
0 |
|
- |
| Cl-14.2, 14.3 Table-2 (vi)(Provision for earthing) |
- |
0 |
|
- |
| Cl-19.11.4.7(Harmonics) |
- |
0 |
|
- |
|
08 Feb, 2027 |
- Included w.e.f 15.07.2025
Exclusion: Cl 19.11.4.1-19.11.4.6(EMI/EMC) |
| 6270 |
Gravitas Laboratories Private Limited, Greater Noida
| 8182606
| IS 513 : Part 2 (2016) |
Cold reduced carbon steel sheet and strip: Part 2 high tensile and multi - Phase steel (Sixth Revision) |
- |
12500 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl 7(UTM) |
- |
1200 |
|
- |
| Cl 8.5(Workmanship) |
- |
500 |
|
- |
| Cl 8.6(Workmanship) |
- |
500 |
|
- |
| Cl 9(Workmanship) |
- |
500 |
|
- |
| Cl 10(Length, Width & Thickness) |
- |
500 |
|
- |
| Cl 7(UTM) |
- |
1200 |
|
- |
| Cl 8.5(Workmanship) |
- |
500 |
|
- |
| Cl 8.6(Workmanship) |
- |
500 |
|
- |
| Cl 9(Workmanship) |
- |
500 |
|
- |
| Cl 10(Length, Width & Thickness) |
- |
500 |
|
- |
| Cl 7(UTM) |
- |
1200 |
|
- |
| Cl 8.5(Workmanship) |
- |
500 |
|
- |
| Cl 8.6(Workmanship) |
- |
500 |
|
- |
| Cl 9(Workmanship) |
- |
500 |
|
- |
| Cl 10(Length, Width & Thickness) |
- |
500 |
|
- |
| 6.0(ALUMINIUM) |
- |
500 |
|
- |
| 6.0(MICRO ALLOYS) |
- |
500 |
|
- |
| 6.0(NITROGEN) |
- |
500 |
|
- |
| 6.0(SILICON) |
- |
500 |
|
- |
| 6.0(MANGANESE) |
- |
500 |
|
- |
| 6.0(PHOSPHORUS) |
- |
500 |
|
- |
| 6.0(SULPHUR) |
- |
500 |
|
- |
| 6.0(CARBON) |
- |
500 |
|
- |
| Cl. 10(Out of square) |
- |
500 |
|
- |
| Cl. 10(Flatness) |
- |
500 |
|
- |
| Cl. 10(Camber) |
- |
500 |
|
- |
| Cl. 10(Width (04)) |
- |
500 |
|
- |
| Cl. 10(Thickness (08)) |
- |
500 |
|
- |
| Cl. 8.5.3 Table 6(Surface Roughness) |
- |
500 |
|
- |
| Cl. 7.3 Table 4A & 4B(Tensile Strain Hardening) |
- |
1500 |
|
- |
| Cl. 7.2 Table 7(Bend Test) |
- |
500 |
|
- |
| Cl 10(Length, Width & Thickness) |
- |
500 |
|
- |
| Cl 9(Workmanship) |
- |
500 |
|
- |
| Cl 8.6(Workmanship) |
- |
500 |
|
- |
| Cl 8.5(Workmanship) |
- |
500 |
|
- |
| Cl 7(UTM) |
- |
1500 |
|
- |
| Cl 7(UTM) |
- |
1500 |
|
- |
| Cl 8.5(Workmanship) |
- |
500 |
|
- |
| Cl 8.6(Workmanship) |
- |
500 |
|
- |
| Cl 9(Workmanship) |
- |
500 |
|
- |
| Cl 10(Length, Width & Thickness) |
- |
500 |
|
- |
| 7.0 & table 3(Chromium as Cr) |
- |
500 |
|
- |
| 7.0 & table 3(Nickel as Ni) |
- |
500 |
|
- |
| 7.0 & table 3(Niobium as Nb) |
- |
500 |
|
- |
| 7.0 & table 3(Vanadium as V) |
- |
500 |
|
- |
| 7.0 & table 3(Titanium as Ti) |
- |
500 |
|
- |
| 7.0 & table 3(Molybdenum as Mp) |
- |
500 |
|
- |
| 7.0 & table 3(Boron as B) |
- |
500 |
|
- |
| 7.0 & table 3(Calcium as Ca) |
- |
500 |
|
- |
| 7.2(Bend test - IS 1599) |
- |
500 |
|
- |
| 8.2(Erichson cupping test - IS 10175 for CR2, CR3, CR4 Grades from 0.5 - 2.0 mm Thickness) |
- |
500 |
|
- |
| 8.3(Rockwell Hardness test -HRB - IS:1586) |
- |
500 |
|
- |
| 7.3(Tensile strain hardening component - IS 15756) |
- |
500 |
|
- |
| 8.0(Surface Roughness) |
- |
500 |
|
- |
| 9(Freedom from defects) |
- |
500 |
|
- |
| Cl. 10(Out of square) |
- |
0 |
|
- |
| Cl. 10(Flatness) |
- |
0 |
|
- |
| Cl. 10(Camber) |
- |
0 |
|
- |
| Cl. 10(Width (04)) |
- |
0 |
|
- |
| Cl. 10(Thickness (08)) |
- |
0 |
|
- |
| Cl. 8.5.3 Table 6(Surface Roughness) |
- |
0 |
|
- |
| Cl. 7.3 Table 4A & 4B(Tensile Strain Hardening) |
- |
0 |
|
- |
| Cl. 7.2 Table 7(Bend Test) |
- |
0 |
|
- |
| Cl 10(Length, Width & Thickness) |
- |
0 |
|
- |
| Cl 9(Workmanship) |
- |
0 |
|
- |
| Cl 8.6(Workmanship) |
- |
0 |
|
- |
| Cl 8.5(Workmanship) |
- |
0 |
|
- |
| Cl 7(UTM) |
- |
0 |
|
- |
| Cl 7(UTM) |
- |
0 |
|
- |
| Cl 8.5(Workmanship) |
- |
0 |
|
- |
| Cl 8.6(Workmanship) |
- |
0 |
|
- |
| Cl 9(Workmanship) |
- |
0 |
|
- |
| Cl 10(Length, Width & Thickness) |
- |
0 |
|
- |
| 7.0 & table 3(Chromium as Cr) |
- |
0 |
|
- |
| 7.0 & table 3(Nickel as Ni) |
- |
0 |
|
- |
| 7.0 & table 3(Niobium as Nb) |
- |
0 |
|
- |
| 7.0 & table 3(Vanadium as V) |
- |
0 |
|
- |
| 7.0 & table 3(Titanium as Ti) |
- |
0 |
|
- |
| 7.0 & table 3(Molybdenum as Mp) |
- |
0 |
|
- |
| 7.0 & table 3(Boron as B) |
- |
0 |
|
- |
| 7.0 & table 3(Calcium as Ca) |
- |
0 |
|
- |
| 7.2(Bend test - IS 1599) |
- |
0 |
|
- |
| 7.3(Tensile strain hardening component - IS 15756) |
- |
0 |
|
- |
| 8.0(Surface Roughness) |
- |
0 |
|
- |
| 9(Freedom from defects) |
- |
0 |
|
- |
|
- |
- Included w.e.f 02.06.2025 |