| 7201 |
Fire Test & Research Laboratory, Sonipat
| 8123835
| IS 907 (1984) |
Specification for suction strainers, cylindrical type for fire fighting purposes (Second Revision) |
- |
10000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 3(Shape and Dimensions) |
- |
8000 |
|
Testing Charges |
| 4(Tolerances) |
- |
1000 |
|
Testing Charges |
| 5(Workmanship and Finish) |
- |
1000 |
|
Testing Charges |
|
31 Dec, 2026 |
- Except Material (Cl.2) |
| 7202 |
Fire Test & Research Laboratory, Sonipat
| 8123835
| IS 906 (1988) |
Specification for revolving branch pipe for fire fighting (Third Revision) |
- |
9500 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4(Dimension and Construction) |
- |
1500 |
|
Testing charges |
| 5(Finish) |
- |
1000 |
|
Testing Charges |
| 6(Performance Requirements) |
- |
7000 |
|
Testing charges |
|
31 Dec, 2026 |
- Excluding: Cl.3.1.1 (a) Sand casting, Cl.3.1.1 (b) re casting, Cl. 3.1.1, c (Hot forging), Cl.3.1.2 (Aluminium Alloy), Cl.3.2 Springs and Cl.3.3 (Washer) |
| 7203 |
Fire Test & Research Laboratory, Sonipat
| 8123835
| IS 4927 (1992) |
Unlined flax canvas hose for fire fighting - Specification (First Revision) |
Unlined Flax Canvas Hose |
18500 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4(Internal diameter of hose) |
- |
500 |
|
- |
| 5(Length) |
- |
750 |
|
- |
| 6.1(Average mass per meter) |
- |
500 |
|
- |
| 6.1(Average mass per meter) |
- |
500 |
|
- |
| 6.1(Average mass per meter) |
- |
500 |
|
- |
| 6.1(Average mass per meter) |
- |
500 |
|
- |
| 7.1(Coil Diameter (Flexibility)) |
- |
500 |
|
- |
| Cl. 8.1, Annexure B & Table 1(Percolation Test) |
- |
1000 |
|
- |
| Cl. 8.1, Annexure B & Table 1(Percolation Test) |
- |
1000 |
|
- |
| Cl. 8.1, Annexure B & Table 1(Percolation Test) |
- |
1000 |
|
- |
| Cl. 8.1, Annexure B & Table 1(Percolation Test) |
- |
1000 |
|
- |
| 9.1(Change in size (Increase in Length)) |
- |
1250 |
|
- |
| 9.2(Change in size (Increase in Outer Diameter)) |
- |
1250 |
|
- |
| 10(Hydrostatic Proof Pressure Test) |
- |
4000 |
|
- |
| 11(Hydrostatic Bursting Pressure Test) |
- |
4000 |
|
- |
|
31 Dec, 2026 |
- Except Material (Cl.3) |
| 7204 |
Fire Test & Research Laboratory, Sonipat
| 8123835
| IS 16018 (2012) |
Wheeled fire extinguishers - Performance and construction - Specification |
Type, Foam based Type, Powders based ABC/ BC/D Type, C |
100500 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl 5.3(Fill Density) |
- |
1000 |
|
NA |
| Cl 5.4(Filling Tolerance) |
- |
1000 |
|
NA |
| Cl 5.5.1(Nominal Charge) |
- |
1000 |
|
NA |
| Cl 6.2.1(Effective Discharge Time) |
- |
500 |
|
NA |
| Cl 6.2.2(Bulk Range) |
- |
500 |
|
NA |
| Cl 6.3(Resistance To Temperature Changes) |
- |
4000 |
|
NA |
| Cl 6.5(Intermittent Discharge Test) |
- |
2000 |
|
NA |
| Cl 4(Types of Wheeled Fire Extinguishers) |
- |
0 |
|
NA |
| 9.1(Colour) |
- |
1000 |
|
NA |
| 8.18.3(Hose Retaining Unit) |
- |
0 |
|
NA |
| 8.18.2(Mobility) |
- |
0.01 |
|
NA |
| 8.18.1(Carriage Assembly) |
- |
1000 |
|
NA |
| 8.17(Dip tubes and Filters for water based Extinguisher) |
- |
1500 |
|
NA |
| 8.15(Safety Locking Devices) |
- |
1000 |
|
NA |
| 8.14(Method of operation for gas cartridge type extinguishers) |
- |
1000 |
|
NA |
| 8.14(Method of operation for carbon dioxide extinguishers) |
- |
1000 |
|
NA |
| 8.13.3(Load test on discharge horn) |
- |
0 |
|
NA |
| 8.13.2(Requirement to prevent loosening or detachment) |
- |
0 |
|
NA |
| 8.13.1(Horn of carbon dioxide extinguisher) |
- |
2000 |
|
NA |
| 8.12(Control valve test) |
- |
1000 |
|
NA |
| 8.11.3(Requirement of burst pressure of hose assemblies for carbon dioxide fire extinguishers) |
- |
0 |
|
NA |
| 8.11.3(Requirement of burst pressure of hose assemblies for except carbon dioxide fire extinguishers) |
- |
0 |
|
NA |
| 8.11.2(Requirement of hose and coupling system) |
- |
0 |
|
NA |
| 8.11.1(Requirement of the Discharge Assemblies) |
- |
2000 |
|
NA |
| 8.9.2(Leakage Test) |
- |
0 |
|
NA |
| 8.8(Safety and Anti-overfill devices) |
- |
1500 |
|
NA |
| 8.7.6(Requirement of edges and surfaces) |
- |
0 |
|
NA |
| 8.7.5(Requirement of burst test of cap,valve and closure) |
- |
0 |
|
NA |
| 8.7.4(Requirement of collar) |
- |
0 |
|
NA |
| 8.7.3(Requirement of filling opening diameter) |
- |
0 |
|
NA |
| 8.7.2(Requirement of threaded connections on cylinder) |
- |
0 |
|
NA |
| 8.7.1(Caps valves and closure) |
- |
1000 |
|
NA |
| 8.6(Minimum wall thickness of the cylinder) |
- |
1000 |
|
NA |
| 8.3.3(Pressure cycling Test) |
- |
3000 |
|
NA |
| 8.3.2(Deformation Test) |
- |
1000 |
|
NA |
| 8.3.1(Burst Test) |
- |
3000 |
|
NA |
| 8.2(High Pressure Cylinder) |
- |
0 |
|
NA |
| 8.1.7(Drain Plug) |
- |
0 |
|
NA |
| 8.1.6(Thread of Plastic Components) |
- |
0 |
|
NA |
| 8.1.4(Construction Requirement) |
- |
0 |
|
NA |
| 8.1.3(Requirement of Welding) |
- |
0 |
|
NA |
| 8.1.2(Leakage Observation during conditioning Test) |
- |
0 |
|
NA |
| 7.2(Class 'B' Fire Test 233B) |
- |
80000 |
|
NA |
| 7.2(Class 'B' Fire Test 183B) |
- |
73000 |
|
NA |
| 7.2(Class 'B' Fire Test 144B) |
- |
62000 |
|
NA |
| 7.2(Class 'B' Fire Test 113B) |
- |
53000 |
|
NA |
| 7.2(Class 'B' Fire Test 89B) |
- |
45000 |
|
NA |
| 7.2(Class 'B' Fire Test 70B) |
- |
37000 |
|
NA |
| 7.2(Class 'B' Fire Test 55B) |
- |
30000 |
|
NA |
| 7.2(Class 'B' Fire Test 34B) |
- |
13500 |
|
NA |
| 7.2(Class 'B' Fire Test 21B) |
- |
9000 |
|
NA |
| 7.2(Class 'B' Fire Test 13B) |
- |
6000 |
|
NA |
| 7.2(Class 'B' Fire Test 8B) |
- |
4500 |
|
NA |
| 7.2(Class 'A' Fire Test 20A) |
- |
65000 |
|
NA |
| 7.2(Class 'A' Fire Test 15A) |
- |
45000 |
|
NA |
| 7.2(Class 'A' Fire Test 10A) |
- |
30000 |
|
NA |
| 7.2(Class 'A' Fire Test 6A) |
- |
32000 |
|
NA |
| 7.2(Class 'A' Fire Test 4A) |
- |
27000 |
|
NA |
| 7.2(Class 'A' Fire Test 3A) |
- |
18000 |
|
NA |
| 7.2(Class 'A' Fire Test 2A) |
- |
16000 |
|
NA |
| 7.2(Class 'A' Fire Test 1A) |
- |
14000 |
|
NA |
| 6.7.4(Displaced Test) |
- |
0 |
|
NA |
| 6.7.3(Nozzle Drop Test) |
- |
0 |
|
NA |
| 6.7.1(Observation of Durability Test after Nozzle Drop Test and Displaced Test) |
- |
4000 |
|
NA |
| 6.6.2(Internal Corrosion Test) |
- |
4000 |
|
NA |
| 6.6.1(External Corrosion Test) |
- |
2000 |
|
NA |
| 6.4(Retention of charge) |
- |
1000 |
|
NA |
| 5.5.2(Gross Mass) |
- |
0 |
|
NA |
| 3.16 and 8.1.1(Determination of maximum service pressure) |
- |
750 |
|
NA |
| 3.19 and 8.3(Determination of Service Pressure) |
- |
750 |
|
NA |
| Cl no 6.8(16018 :2012) |
- |
25000 |
|
NA |
| Cl no 6.8(16018 :2012) |
- |
0 |
|
NA |
| Cl 6.1(Operating Temperature) |
- |
300 |
|
NA |
| 6.7.2(Durability test of trailer mounted fire extinguisher) |
- |
3000 |
|
NA |
|
31 Dec, 2026 |
- Included w.e.f
17.04.2018
Except : Class D fire test
(cl.7.3)),Requirement of
the plastic component
(Cl. 8.10), Pressure
Gauge for Low Pressure
Extinguisher (Cl. 8.16)
& Gasket & O-ring (Cl.
8.19), Cl. 8.4.1.1 (carbon, sulphur, phosphorus), Cl.8.4.2.2 (Carbon) |
| 7205 |
Fire Test & Research Laboratory, Sonipat
| 8123835
| IS 15683 (2018) |
Portable Fire Extinguishers — Performance and Construction — Specification ( First Revision ) |
Water, Foam, Powder based ABC/BC/D type, Clean Agent Wa |
291800 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl. 5.3.1(Filling Requirements) |
- |
200 |
|
- |
| Cl. 5.3.2(Filling Requirements) |
- |
200 |
|
- |
| Cl. 5.3.3(Capacities) |
- |
0 |
|
- |
| Cl. 7.2 - Table 1(GENERAL OPERATING PERFORMANCE REQUIREMENTS) |
- |
500 |
|
- |
| Cl. 7.3(Resistance to Temperature changes) |
- |
2000 |
|
- |
| Cl 7.5.1(Impact Resistance Test) |
- |
500 |
|
- |
| Cl 7.5.2(Vibration Resistance Test) |
- |
2000 |
|
- |
| Cl 7.6(Resistance to Corrosion) |
- |
0 |
|
- |
| Cl 7.7(Tapping Test) |
- |
1000 |
|
- |
| Cl 7.8(Intermittent Discharge Test) |
- |
1000 |
|
- |
| Cl 8.1(Rating Suitability for the Various Classes of Fire) |
- |
0 |
|
- |
| Cl 9(CONSTRUCTION REQUIREMENTS) |
- |
0 |
|
- |
| Cl 9.2.2(Burst Test) |
- |
2000 |
|
- |
| Cl 9.2.3(Crushing Test) |
- |
2000 |
|
- |
| Cl 9.2.4(Pressure Cycling Test) |
- |
2000 |
|
- |
| Cl 9.3(Carrying Handle) |
- |
500 |
|
- |
| Cl 9.4(Mounting) |
- |
500 |
|
- |
| Cl 9.5(Caps, Valves and Closures) |
- |
500 |
|
- |
| Cl 9.7.1(Requirements for Plastics Components) |
- |
2000 |
|
- |
| Cl 9.7.2(Requirements for Plastics Components) |
- |
2000 |
|
- |
| Cl 9.7.3(Requirements for Plastics Components) |
- |
2000 |
|
- |
| Cl 9.8(Hose Assemblies) |
- |
1000 |
|
- |
| Cl 9.9 - Table 10(Method of Operation) |
- |
200 |
|
- |
| Cl 9.10(Safety-Locking Devices) |
- |
200 |
|
- |
| Cl 9.11.1(Requirements for Pressure Gauges and Indicators for Low-Pressure Extinguishers) |
- |
5000 |
|
- |
| Cl 9.12(Dip-Tubes and Filters — Water-Based Extinguishers) |
- |
500 |
|
- |
| Cl 9.13(Horn Test for Carbon Dioxide (CO2) Extinguishers) |
- |
1000 |
|
- |
| Cl 9.14(Requirements for Extinguishants Filled in the Extinguisher) |
- |
2500 |
|
For ABC = Rs. 1000/-
For BC = Rs. 500/-
For Foam = Rs. 1000/- |
| Cl 9.11.3(Burst Strength Test — Gauges and Indicators) |
- |
0 |
|
- |
| Cl 9.11.4(Water Resistance Test — Gauges and Indicators) |
- |
0 |
|
- |
| Cl 9.11.2(Calibration Test - Gauges and Indicators) |
- |
0 |
|
- |
| Cl 10(MARKING AND COLOUR) |
- |
0 |
|
- |
| 3.5 & 9.2.1.1(Determination of Service Pressure ) |
- |
50 |
|
- |
| 3.6 & 9.2.1.8(Determination of Maximum Service Pressure ) |
- |
50 |
|
- |
| 6.1(Determination of Test Pressure) |
- |
50 |
|
- |
| 6.2(Determination of Minimum Burst Pressure) |
- |
50 |
|
- |
| 7.4.1.(Retention of charge following partial discharge) |
- |
500 |
|
- |
| 7.4.2(Leakage Test) |
- |
1000 |
|
- |
| 7.6.1(External Corrosion Test for all types of extinguishers) |
- |
2000 |
|
- |
| 7.6.1(Internal Corrosion Test Test is applicable only for water based & clean agent PFEs) |
- |
2000 |
|
- |
| 8.1.1, 8.2.2 a) & 8.3(Class A Fire Test) |
- |
105000 |
|
1A = 10000/-
2A = 12000/-
3A = 14000/-
4A = 18000/-
6A = 30000/-
10A = 55000/-
15A = 80000/-
20A = 105000/- |
| 8.1.2, 8.2.2 b) & 8.4(Class B Fire Test) |
- |
80000 |
|
8B = 4500/-
13B = 6000/-
21B = 9000/-
34B = 13500/-
55B = 30000/-
70B = 37000/-
89B = 45000/-
113B = 53000/-
144B = 62000/-
183B = 73000/-
233B = 80000/- |
| 8.1.4 & 8.5(Class D Test fire) |
- |
16000 |
|
- |
| 8.1.5, 8.2.2(C) , 8.6, 8.7(Class F Splash Test) |
- |
27000 |
|
5F = 8000/-
15F = 12000/-
25F = 18000/-
75F = 27000/- |
| 8.8(Electrical Conductivity of Extinguishers Discharge ) |
- |
30000 |
|
- |
| 9.2.1.2(Construction requirement for stand vertically upright position) |
- |
500 |
|
- |
| 9.2.1.3(Requirement of Welding) |
- |
0 |
|
- |
| 9.2.1.4(Construction requirement of Neck Ring) |
- |
0 |
|
- |
| 9.2.1.5(Cast Analysis Certifcate) |
- |
0 |
|
- |
| 9.2.1.6(Type of threads on parts made of plastic component joining metal parts) |
- |
0 |
|
- |
| 9.2.1.7(Construction requirement for the bottom of the extinguisher) |
- |
0 |
|
- |
| 9.2.5.3, (Measure Thickness of the cylinder) |
- |
100 |
|
- |
| 9.2.6.3 (Measure Thickness of the cylinder (S.S. Body)) |
- |
100 |
|
- |
| 9.2.7(Measure Thickness of the cylinder (Aluminium body)) |
- |
100 |
|
- |
| 9.2.8(Composite Cylinder) |
- |
0 |
|
- |
| 9.6(Safety Device) |
- |
0 |
|
- |
| Cl. 5.3.2(Filling Requirements) |
- |
0 |
|
- |
| Cl. 5.3.2(Filling Requirements) |
- |
0 |
|
- |
| Cl. 5.3.2(Filling Requirements) |
- |
0 |
|
- |
| Cl. 5.3.2(Filling Requirements) |
- |
0 |
|
- |
| Cl. 5.3.2(Filling Requirements) |
- |
0 |
|
- |
| Cl. 5.3.3(Capacities) |
- |
0 |
|
- |
| Cl. 5.3.3(Capacities) |
- |
0 |
|
- |
| Cl. 5.3.3(Capacities) |
- |
0 |
|
- |
| Cl. 5.3.3(Capacities) |
- |
0 |
|
- |
| Cl. 5.3.3(Capacities) |
- |
0 |
|
- |
| Cl. 7.2 - Table 1(GENERAL OPERATING PERFORMANCE REQUIREMENTS) |
- |
0 |
|
- |
| Cl 7.8(Intermittent Discharge Test) |
- |
0 |
|
- |
| 7.6.2(Internal Corrosion Test for Extinguishers Using Water-Based Medium and Clean Agent) |
- |
4000 |
|
- |
| 9.14.1(Content of Mono Ammonium Phosphate) |
- |
2000 |
|
- |
| 9.14.3(Surface Tension of Foam Solution) |
- |
1000 |
|
- |
| 9.14.2(Content of Sodium Bicarbonate/Potassium Picarbonate for BC Powder) |
- |
- |
|
- |
|
31 Dec, 2026 |
- Revised version included w.e.f 03.05.2019
Excluding :
Composition of welded low carbon steel cylinders (Cl. 9.2.5.1)& (Cl.9.2.5.2)
Carbon content of Stainless Steel Cylinder (Cl.9.2.6.2)&(Cl.9.2.6.2) |
| 7206 |
Fire Test & Research Laboratory, Sonipat
| 8123835
| IS 5290 (1993) |
Landing valves - Specification (Third Revision) |
Type-A and Type-B |
10000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 5, 5.1 (a) fig-1, type A(Types AND DIMENSIONS) |
- |
200 |
|
- |
| 5, 5.1 (b) fig-2, type B(Types AND DIMENSIONS) |
- |
200 |
|
- |
| 5.2(Types AND DIMENSIONS) |
- |
1000 |
|
- |
| 6, 6.1(Finish) |
- |
300 |
|
- |
| 7, 7.1(7 PERFORMANCE REQUIREMENTS, Water Tightness Test for the Valve) |
- |
1500 |
|
- |
| 7, 7.2(hydrostatics pressure tests) |
- |
2000 |
|
- |
| 7, 7.3(Flow test, pressure 7 kgf/cm2) |
- |
4000 |
|
- |
| 6, 6.2(Finish) |
- |
500 |
|
- |
|
31 Dec, 2026 |
- Excluding: Cl.4.1, Cl.4.1.1, 4.2,4.3,4.4,.4.5 |
| 7207 |
Fire Test & Research Laboratory, Sonipat
| 8123835
| IS 4989 (2018) |
Foam concentrate for producing mechanical foam for fire fighting - Specification (Fourth Revision) |
AFFF, PF, FP, FFFP, AR-AFFF,AR-FP, AR-FFFP, SF Type, |
87000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl. 4.1, Table 1, Sr. No. 1 (Visual Examination ) |
- |
500 |
|
AFFF, FFFP, FP, PF, SF, AR-AFFF, AR-FFFP & AR-FP |
| Cl. 4.1, Table 1, Sr. No. 3(pH (Original Sample)) |
- |
1000 |
|
AFFF, FFFP, FP, PF, SF, AR-AFFF, AR-FFFP & AR-FP |
| Cl. 4.1, Table 1, Sr. No. 10(spreading coefficient) |
- |
1000 |
|
AFFF, FFFP, FP, PF, SF, AR-AFFF, AR-FFFP & AR-FP |
| Cl. 4.1, Table 1, Sr. No. 8(Surface tension) |
- |
500 |
|
AFFF, FFFP, FP, PF, SF, AR-AFFF, AR-FFFP & AR-FP |
| Cl. 4.1, Table 1, Sr. No. 3(pH (ageing Sample)) |
- |
1000 |
|
AFFF, FFFP, FP, PF, SF, AR-AFFF, AR-FFFP & AR-FP |
| Clause No. 4.1(General observation regarding colour and odour) |
- |
0 |
|
AFFF, FFFP, FP, PF, SF, AR-AFFF, AR-FFFP & AR-FP |
| Clause No. 4.1(General observation regarding colour and odour) |
- |
0 |
|
AFFF, FFFP, FP, PF, SF, AR-AFFF, AR-FFFP & AR-FP |
| Clause No. 4.2, Sr. No. I of Table 1, Annex-A-1(Visual Examination) |
- |
500 |
|
AFFF, FFFP, FP, PF, SF, AR-AFFF, AR-FFFP & AR-FP |
| Clause No. 4.2, Sr. No. II of Table 1, Annex-A-2(Freezing and thawing) |
- |
500 |
|
AFFF, FFFP, FP, PF, SF, AR-AFFF, AR-FFFP & AR-FP |
| Clause No. 4.2, Sr. No. III of Table 1, Annex-B(pH of original sample) |
- |
500 |
|
AFFF, FFFP, FP, PF, SF, AR-AFFF, AR-FFFP & AR-FP |
| Clause No. 4.2, Sr. No. III of Table 1, Annex-B(pH of aged sample) |
- |
500 |
|
AFFF, FFFP, FP, PF, SF, AR-AFFF, AR-FFFP & AR-FP |
| Clause No. 4.2, Sr. No. III of Table 1, Annex-B(pH of original sample) |
- |
500 |
|
AFFF, FFFP, FP, PF, SF, AR-AFFF, AR-FFFP & AR-FP |
| Clause No. 4.2, Sr. No. III of Table 1, Annex-B(pH of aged sample) |
- |
500 |
|
AFFF, FFFP, FP, PF, SF, AR-AFFF, AR-FFFP & AR-FP |
| Clause No. 4.2, Sr. No. IV of Table 1, Annex-C(Specific Gravity of original sample) |
- |
500 |
|
AFFF, FFFP, FP, PF, SF, AR-AFFF, AR-FFFP & AR-FP |
| Clause No. 4.2, Sr. No. IV of Table 1, Annex-C(Specific Gravity of aged sample) |
- |
500 |
|
AFFF, FFFP, FP, PF, SF, AR-AFFF, AR-FFFP & AR-FP |
| Clause No. 4.2, Sr. No. IV of Table 1, Annex-C(Specific Gravity of original sample) |
- |
500 |
|
AFFF, FFFP, FP, PF, SF, AR-AFFF, AR-FFFP & AR-FP |
| Clause No. 4.2, Sr. No. IV of Table 1, Annex-C(Specific Gravity of aged sample) |
- |
500 |
|
AFFF, FFFP, FP, PF, SF, AR-AFFF, AR-FFFP & AR-FP |
| Clause No. 4.2, Sr. No. IV of Table 1, Annex-C(Specific Gravity of original sample) |
- |
500 |
|
AFFF, FFFP, FP, PF, SF, AR-AFFF, AR-FFFP & AR-FP |
| Clause No. 4.2, Sr. No. IV of Table 1, Annex-C(Specific Gravity of aged sample) |
- |
500 |
|
AFFF, FFFP, FP, PF, SF, AR-AFFF, AR-FFFP & AR-FP |
| Clause No. 4.2, Sr. No. IV of Table 1, Annex-C(Specific Gravity of original sample) |
- |
500 |
|
AFFF, FFFP, FP, PF, SF, AR-AFFF, AR-FFFP & AR-FP |
| Clause No. 4.2, Sr. No. IV of Table 1, Annex-C(Specific Gravity of aged sample) |
- |
500 |
|
AFFF, FFFP, FP, PF, SF, AR-AFFF, AR-FFFP & AR-FP |
| Clause No. 4.2, Sr. No. VI of Table 1, using viscosity meter see sl No. (iv) of table 2 of IS 1206 (Part 3)(Viscosity (Kinematic)) |
- |
1000 |
|
AFFF, FFFP, FP, PF, SF, AR-AFFF, AR-FFFP & AR-FP |
| Clause No. 4.2, Sr. No. VI of Table 1, using viscosity meter see sl No. (iv) of table 2 of IS 1206 (Part 3)(Viscosity (Kinematic)) |
- |
1000 |
|
AFFF, FFFP, FP, PF, SF, AR-AFFF, AR-FFFP & AR-FP |
| Clause No. 4.2, Sr. No. VII of Table 1, Annex-E(Pour Point) |
- |
1000 |
|
AFFF, FFFP, FP, PF, SF, AR-AFFF, AR-FFFP & AR-FP |
| Clause No. 4.2, Sr. No. V of Table 1, Annex-D(Misciblity with distilled water) |
- |
500 |
|
AFFF, FFFP, FP, PF, SF, AR-AFFF, AR-FFFP & AR-FP |
| Clause No. 4.2, Sr. No. V of Table 1, Annex-D(Misciblity with synthetic sea water) |
- |
500 |
|
AFFF, FFFP, FP, PF, SF, AR-AFFF, AR-FFFP & AR-FP |
| Clause No. 4.2, Sr. No. VIII of Table 1, Annex-F(Sludge Content for Original Sample) |
- |
1000 |
|
AFFF, FFFP, FP, PF, SF, AR-AFFF, AR-FFFP & AR-FP |
| Clause No. 4.2, Sr. No. VIII of Table 1, Annex-F(Sludge Content for Aged Sample) |
- |
1000 |
|
AFFF, FFFP, FP, PF, SF, AR-AFFF, AR-FFFP & AR-FP |
| Clause No. 4.2, Sr. No. VIII of Table 1, Annex-F(Sludge Content for Original Sample) |
- |
1000 |
|
AFFF, FFFP, FP, PF, SF, AR-AFFF, AR-FFFP & AR-FP |
| Clause No. 4.2, Sr. No. VIII of Table 1, Annex-F(Sludge Content for Aged Sample) |
- |
1000 |
|
AFFF, FFFP, FP, PF, SF, AR-AFFF, AR-FFFP & AR-FP |
| Clause No. 4.2, Sr. No. IX of Table 1, Annex-G(Surface Tension) |
- |
500 |
|
AFFF, FFFP, FP, PF, SF, AR-AFFF, AR-FFFP & AR-FP |
| Clause No. 4.2, Sr. No. X of Table 1, Annex-G(Spreading Coefficient) |
- |
1000 |
|
AFFF, FFFP, FP, PF, SF, AR-AFFF, AR-FFFP & AR-FP |
| Clause No. 4.2, Sr. No. X of Table 1, Annex-G(Spreading Coefficient) |
- |
1000 |
|
AFFF, FFFP, FP, PF, SF, AR-AFFF, AR-FFFP & AR-FP |
| Clause No. 4.2, Sr. No. I of Table 2, Annex-J(Expansion) |
- |
1000 |
|
AFFF, FFFP, FP, PF, SF, AR-AFFF, AR-FFFP & AR-FP |
| Clause No. 4.2, Sr. No. I of Table 2, Annex-J(Expansion) |
- |
1000 |
|
AFFF, FFFP, FP, PF, SF, AR-AFFF, AR-FFFP & AR-FP |
| Clause No. 4.2, Sr. No. II of Table 2, Annex-J(25% Drainage Time) |
- |
500 |
|
AFFF, FFFP, FP, PF, SF, AR-AFFF, AR-FFFP & AR-FP |
| Clause No. 4.2, Sr. No. II of Table 2, Annex-J(25% Drainage Time) |
- |
500 |
|
AFFF, FFFP, FP, PF, SF, AR-AFFF, AR-FFFP & AR-FP |
| Clause No. 4.2, Sr. No. II of Table 2, Annex-J(25% Drainage Time) |
- |
500 |
|
AFFF, FFFP, FP, PF, SF, AR-AFFF, AR-FFFP & AR-FP |
| Clause No. 4.2, Sr. No. II of Table 2, Annex-J(25% Drainage Time) |
- |
500 |
|
AFFF, FFFP, FP, PF, SF, AR-AFFF, AR-FFFP & AR-FP |
| Clause No. 4.2, Sr. No. III(a) of Table 2, Annex-K(Fire Control Time for Hydrocarbon Fires (Non Polar) with potable water) |
- |
5000 |
|
AFFF, FFFP, FP, PF, SF, AR-AFFF, AR-FFFP & AR-FP |
| Clause No. 4.2, Sr. No. III(a) of Table 2, Annex-K(Fire Control Time for Hydrocarbon Fires (Non Polar) with potable water) |
- |
5000 |
|
AFFF, FFFP, FP, PF, SF, AR-AFFF, AR-FFFP & AR-FP |
| Clause No. 4.2, Sr. No. III(b) of Table 2, Annex-K(Fire Extinction Time for Hydrocarbon Fires (Non Polar) with potable water) |
- |
5000 |
|
AFFF, FFFP, FP, PF, SF, AR-AFFF, AR-FFFP & AR-FP |
| Clause No. 4.2, Sr. No. III(b) of Table 2, Annex-K(Fire Extinction Time for Hydrocarbon Fires (Non Polar) with potable water) |
- |
5000 |
|
AFFF, FFFP, FP, PF, SF, AR-AFFF, AR-FFFP & AR-FP |
| Clause No. 4.2, Sr. No. III(b) of Table 2, Annex-K(Fire Extinction Time for Hydrocarbon Fires (Non Polar) with potable water) |
- |
5000 |
|
AFFF, FFFP, FP, PF, SF, AR-AFFF, AR-FFFP & AR-FP |
| Clause No. 4.2, Sr. No. III(c) of Table 2, Annex-K(Sealability/Film forming for Hydrocarbon Fires (Non Polar) with potable water) |
- |
5000 |
|
AFFF, FFFP, FP, PF, SF, AR-AFFF, AR-FFFP & AR-FP |
| Clause No. 4.2, Sr. No. III(d) of Table 2, Annex-K(Burn Back for Hydrocarbon Fires (Non Polar) with potable water) |
- |
5000 |
|
AFFF, FFFP, FP, PF, SF, AR-AFFF, AR-FFFP & AR-FP |
| Clause No. 4.2, Sr. No. III(d) of Table 2, Annex-K(Burn Back for Hydrocarbon Fires (Non Polar) with potable water) |
- |
5000 |
|
AFFF, FFFP, FP, PF, SF, AR-AFFF, AR-FFFP & AR-FP |
| Clause No. 4.2, Sr. No. III(a) of Table 2, Annex-K(Fire Control Time for Hydrocarbon Fires (Non Polar) with synthetic sea water) |
- |
5000 |
|
AFFF, FFFP, FP, PF, SF, AR-AFFF, AR-FFFP & AR-FP |
| Clause No. 4.2, Sr. No. III(a) of Table 2, Annex-K(Fire Control Time for Hydrocarbon Fires (Non Polar) with synthetic sea water) |
- |
5000 |
|
AFFF, FFFP, FP, PF, SF, AR-AFFF, AR-FFFP & AR-FP |
| Clause No. 4.2, Sr. No. III(b) of Table 2, Annex-K(Fire Extinction Time for Hydrocarbon Fires (Non Polar) with synthetic sea water) |
- |
5000 |
|
AFFF, FFFP, FP, PF, SF, AR-AFFF, AR-FFFP & AR-FP |
| Clause No. 4.2, Sr. No. III(b) of Table 2, Annex-K(Fire Extinction Time for Hydrocarbon Fires (Non Polar) with synthetic sea water) |
- |
5000 |
|
AFFF, FFFP, FP, PF, SF, AR-AFFF, AR-FFFP & AR-FP |
| Clause No. 4.2, Sr. No. III(b) of Table 2, Annex-K(Fire Extinction Time for Hydrocarbon Fires (Non Polar) with synthetic sea water) |
- |
5000 |
|
AFFF, FFFP, FP, PF, SF, AR-AFFF, AR-FFFP & AR-FP |
| Clause No. 4.2, Sr. No. III(c) of Table 2, Annex-K(Sealability/Film forming for Hydrocarbon Fires (Non Polar) with synthetic sea water) |
- |
5000 |
|
AFFF, FFFP, FP, PF, SF, AR-AFFF, AR-FFFP & AR-FP |
| Clause No. 4.2, Sr. No. III(d) of Table 2, Annex-K(Burn Back for Hydrocarbon Fires (Non Polar) with synthetic sea water) |
- |
5000 |
|
AFFF, FFFP, FP, PF, SF, AR-AFFF, AR-FFFP & AR-FP |
| Clause No. 4.2, Sr. No. III(d) of Table 2, Annex-K(Burn Back for Hydrocarbon Fires (Non Polar) with synthetic sea water) |
- |
5000 |
|
AFFF, FFFP, FP, PF, SF, AR-AFFF, AR-FFFP & AR-FP |
| Clause No. 4.2, Sr. No. IV(a) of Table 2, Annex-M(Fire Control Time for Polar Solvent Fire) |
- |
5000 |
|
AR-AFFF, AR-FFFP & AR-FP |
| Clause No. 4.2, Sr. No. IV(a) of Table 2, Annex-M(Fire Control Time for Polar Solvent Fire) |
- |
5000 |
|
AR-AFFF, AR-FFFP & AR-FP |
| Clause No. 4.2, Sr. No. IV(b) of Table 2, Annex-M(Fire Extinction Time Polar Solvent Fire) |
- |
5000 |
|
AR-AFFF, AR-FFFP & AR-FP |
| Clause No. 4.2, Sr. No. IV(b) of Table 2, Annex-M(Fire Extinction Time Polar Solvent Fire) |
- |
5000 |
|
AR-AFFF, AR-FFFP & AR-FP |
| Clause No. 4.2, Sr. No. IV(c) of Table 2, Annex-M(Sealability/Film forming for Polar Solvent Fires) |
- |
5000 |
|
AR-AFFF, AR-FFFP & AR-FP |
| Clause No. 4.2, Sr. No. IV(d) of Table 2, Annex-M(Burn Back for Polar Solvent Fires) |
- |
5000 |
|
AR-AFFF, AR-FFFP & AR-FP |
| Clause No. 4.2, Sr. No. IV(d) of Table 2, Annex-M(Burn Back for Polar Solvent Fires) |
- |
5000 |
|
AR-AFFF, AR-FFFP & AR-FP |
| Clause No. 4.2, Sr. No. IV(a) of Table 2, Annex-M(Fire Control Time for Polar Solvent Fire with synthetic sea water) |
- |
5000 |
|
AR-AFFF, AR-FFFP & AR-FP |
| Clause No. 4.2, Sr. No. IV(a) of Table 2, Annex-M(Fire Control Time for Polar Solvent Fire with synthetic sea water) |
- |
5000 |
|
AR-AFFF, AR-FFFP & AR-FP |
| Clause No. 4.2, Sr. No. IV(b) of Table 2, Annex-M(Fire Extinction Time Polar Solvent Fire with synthetic sea water) |
- |
5000 |
|
AR-AFFF, AR-FFFP & AR-FP |
| Clause No. 4.2, Sr. No. IV(b) of Table 2, Annex-M(Fire Extinction Time Polar Solvent Fire with synthetic sea water) |
- |
5000 |
|
AR-AFFF, AR-FFFP & AR-FP |
| Clause No. 4.2, Sr. No. IV(c) of Table 2, Annex-M(Sealability/Film forming for Polar Solvent Fires with synthetic sea water) |
- |
5000 |
|
AR-AFFF, AR-FFFP & AR-FP |
| Clause No. 4.2, Sr. No. IV(d) of Table 2, Annex-M(Burn Back for Polar Solvent Fires with synthetic sea water) |
- |
5000 |
|
AR-AFFF, AR-FFFP & AR-FP |
| Clause No. 4.2, Sr. No. IV(d) of Table 2, Annex-M(Burn Back for Polar Solvent Fires with synthetic sea water) |
- |
5000 |
|
AR-AFFF, AR-FFFP & AR-FP |
|
31 Dec, 2026 |
- Revised version included w.e.f 03.05.2019 |
| 7208 |
Fire Test & Research Laboratory, Sonipat
| 8123835
| IS 4308 (2019) |
Dry Chemical Powders for Fire Fighting — BC, ABC and D Types — Specification ( Third Revision ) |
BC Type, ABC Type, D Type |
49000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Clause 5 Table 1(iii)(Apparent density (Declared value by
the manufacturer)) |
- |
500 |
|
ABC, BC & D TYPE |
| Clause 5 Table 1(i)(Main Chemical constituent-Sodium/Potassium
bicarbonate
) |
- |
1500 |
|
BC |
| Clause 5 Table 1(iv)(Particle size / sieve analysis (Declared value by
the manufacturer)) |
- |
500 |
|
ABC, BC & D TYPE |
| Clause 5 Table 1(vi)(Water repellency) |
- |
500 |
|
ABC, BC & D TYPE |
| Clause 5 Table 1(vi)(Water repellency) |
- |
500 |
|
ABC, BC & D TYPE |
| Clause 5 Table 1(vii)(Moisture content) |
- |
500 |
|
ABC, BC & D TYPE |
| Clause 5 Table 1(viii)(Rate of flow) |
- |
500 |
|
ABC, BC & D TYPE |
| Clause 5 Table 1(ix)(Foam compatibility (required if declared by the manufacturer)) |
- |
2000 |
|
ABC, BC & D TYPE |
| Clause 5 Table 1(x)(Fire test) |
- |
30000 |
|
For A class - 12000/-
For B Class - Rs. 30000/-
For D Class - Rs. 7000/- |
| Clause 5 Table 1(xi)(Temperature resistance test) |
- |
1000 |
|
ABC, BC & D TYPE |
| Clause 5 Table 1(xii)(colour) |
- |
0 |
|
ABC, BC & D TYPE |
| Clause No. 5, Sr. No. I of Table 1, Annex-A(Main Chemical Constituent of ABC Powder) |
- |
1000 |
|
ABC |
| Clause No. 5, Sr. No. I of Table 1, Annex-A(Main Chemical Constituent for BC Powder) |
- |
500 |
|
BC |
| Clause No. 5, Sr. No. I of Table 1, Annex-A(Main Chemical Constituent for D Powder) |
- |
1500 |
|
D TYPE |
| Clause No. 5, Sr. No. II of Table 1, Annex-A(Minimum Main Chemical Constituent for ABC Powder) |
- |
1000 |
|
ABC |
| Clause No. 5, Sr. No. II of Table 1, Annex-A(Minimum Main Chemical Constituent for BC Powder) |
- |
500 |
|
BC TYPE |
| Clause No. 5, Sr. No. II of Table 1, Annex-A(Minimum Main Chemical Constituent for D Powder) |
- |
1500 |
|
D TYPE |
| Clause No. 5, Sr. No. III of Table 1, Annex-B(Aparent Denisty) |
- |
500 |
|
ABC, BC & D TYPE |
| Clause No. 5, Sr. No. IV of Table 1, Annex-C(Particle Size/ Sieve Analysis) |
- |
500 |
|
ABC, BC & D TYPE |
| Clause No. 5, Sr. No. V of Table 1, Annex-D(Hygroscopicity) |
- |
500 |
|
ABC, BC & D TYPE |
| Clause No. 5, Sr. No. VI of Table 1, Annex-E(Water Repellency) |
- |
500 |
|
ABC, BC & D TYPE |
| Clause No. 5, Sr. No. VII of Table 1, Annex-F(Moisture Content) |
- |
500 |
|
ABC, BC & D TYPE |
| Clause No. 5, Sr. No. VIII of Table 1, Annex-G(Rate of flow/ Free flowing Characteristic) |
- |
500 |
|
ABC, BC & D TYPE |
| Clause No. 5, Sr. No. VIII of Table 1, Annex-G(Rate of flow/ Free flowing Characteristic for Class D Powder) |
- |
500 |
|
D TYPE |
| Clause No. 5, Sr. No. IX of Table 1, Annex-H(Foam Compatibility) |
- |
2000 |
|
ABC, BC & D TYPE |
| Clause No. 5, Sr. No. X of Table 1, Annex-J(Fire test for Class 'A') |
- |
12000 |
|
ABC |
| Clause No. 5, Sr. No. X of Table 1, Annex-J(Fire test for Class 'B') |
- |
30000 |
|
ABC & BC |
| Clause No. 5, Sr. No. X of Table 1, Annex-J(Fire test for Class 'D') |
- |
7000 |
|
D TYPE |
| Clause No. 5, Sr. No. XI of Table 1, Annex-K(Temperature Resistance Test) |
- |
1000 |
|
ABC, BC & D TYPE |
| Clause No. 5, Sr. No. XII of Table 1(Colour of 'ABC' Powder) |
- |
0 |
|
ABC TYPE |
| Clause No. 5, Sr. No. XII of Table 1(Colour of 'BC' Powder) |
- |
0 |
|
BC TYPE |
| Clause No. 5, Sr. No. XII of Table 1(Colour of 'D' Powder) |
- |
0 |
|
D TYPE |
|
31 Dec, 2026 |
- Revised version i . Included w.e.f 03.05.2019 |
| 7209 |
Fire Test & Research Laboratory, Sonipat
| 8123835
| IS 903 (1993) |
Specification for Fire Hose Delivery Couplings, Branch Pipe, Nozzles And Nozzle Spanner - Specificaion |
- |
10000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 3(Finish and workmanship) |
- |
250 |
|
- |
| 6.3(Hydraulic test requirement) |
- |
2000 |
|
- |
| 6(Branch pipe) |
- |
750 |
|
- |
| 7(Nozzle) |
- |
500 |
|
- |
| 7.3(Hydraulic test requirement) |
- |
2000 |
|
- |
| 5.3(Size and Dimension ) |
- |
750 |
|
- |
| 5.4(Hydraulic test requirement) |
- |
2000 |
|
- |
| 5(Delivery hose coupling) |
- |
500 |
|
- |
| 3(Finish and workmanship) |
- |
250 |
|
- |
| 6(Branch pipe) |
- |
750 |
|
- |
| 6.3(Hydraulic test requirement) |
- |
2000 |
|
- |
| 7.3(Hydraulic test requirement) |
- |
2000 |
|
- |
| 5(Delivery hose coupling) |
- |
500 |
|
- |
| 5.3(Size and Dimension ) |
- |
750 |
|
- |
| 5.4(Hydraulic test requirement) |
- |
2000 |
|
- |
| 8.2(Shape & Dimensions of Spanner) |
- |
500 |
|
- |
| 8.4(Deflection test of Spanner) |
- |
500 |
|
- |
| 8.3(Coating of Nozzle Spanner) |
- |
0 |
|
- |
| 3(Finish and workmanship) |
- |
250 |
|
- |
| 7(Nozzle) |
- |
500 |
|
- |
| 5.3(Size and Dimension ) |
- |
750 |
|
- |
| 5(Delivery hose coupling) |
- |
500 |
|
- |
| 5.4(Hydraulic test requirement) |
- |
2000 |
|
- |
|
31 Dec, 2026 |
- Except Material (Cl.5.2, 6.1, 7.1 & 8.1) |
| 7210 |
Fire Test & Research Laboratory, Sonipat
| 8123835
| IS 884 (1985) |
Apecification for first - Aid hose - Reel for fire fighting (First Revision) |
Type-A and Type-B |
12750 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl 5.1(Dimensions) |
- |
150 |
|
- |
| Cl 5.2(Resistance to Leakage) |
- |
1000 |
|
- |
| Cl 5.3(Strength) |
- |
3000 |
|
- |
| Cl 5.3(Strength) |
- |
3000 |
|
- |
| Cl 5.4(Range & Water Flow Rate) |
- |
2500 |
|
- |
| Cl 5.5(Swinging) |
- |
500 |
|
- |
| Cl 5.6(Reel Action) |
- |
500 |
|
- |
| Cl 6(Workmanship) |
- |
500 |
|
- |
| Cl 7(Painting) |
- |
500 |
|
- |
| Cl 5.1(Dimensions) |
- |
250 |
|
- |
| Cl 5.1(Dimensions) |
- |
150 |
|
- |
| Cl 5.1(Dimensions) |
- |
150 |
|
- |
| Cl 5.1(Dimensions) |
- |
150 |
|
- |
| Cl 5.1(Dimensions) |
- |
150 |
|
- |
| Cl 5.1(Dimensions) |
- |
150 |
|
- |
| Cl 5.1(Dimensions) |
- |
150 |
|
- |
|
31 Dec, 2026 |
- Except Material (Cl.3.1) |
| 7211 |
Fire Test & Research Laboratory, Sonipat
| 8123835
| IS 636 (2018) |
Non - Percolating flexible fire fighting delivery hose - Specification (Fourth Revision) |
Type 1, Type 2 & Type 3 |
32000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl 6.1.1(Inner lining shall be of rubber or rubberized fabric lining which is generally smooth and practically free
from pitting and other imperfections) |
- |
500 |
|
Type - 1 = 500/-, Type - 2 = 500/-, Type-3 = 500/- |
| Cl 6.1.2(Externally applied elastomeric coating or
covering of the reinforcement, if present shall be
generally smooth and practically free from pitting and
other imperfections) |
- |
500 |
|
Type - 1 = 500/-, Type - 2 = 500/-, Type-3 = 500/- |
| Cl 6.1.3(The jacket shall be practically free from dirt, knots,
lumps, irregularities of the yarn and other visible defects.) |
- |
500 |
|
Type - 1 = 500/-, Type - 2 = 500/-, Type-3 = 500/- |
| Cl.6.2(The internal diameter of the hose shall be measured by
a suitable conical plug gauge and shall conform to the
specified diameter with a tolerance of plus 2 and minus
0.0 mm.) |
- |
500 |
|
Type - 1 = 500/-, Type - 2 = 500/-, Type-3 = 500/- |
| Cl.6.3(Unless specified otherwise, the standard length shall
be 30 m. Unless otherwise specified, a tolerance of ± 2
percent shall be permitted on the length prescribed for
the hose by the purchaser but the total of all lengths of
hose supplied shall be not less than the total quantity
specified by the purchaser.) |
- |
500 |
|
Type - 1 = 500/-, Type - 2 = 500/-, Type-3 = 500/- |
| Cl.6.4(The average mass of hose per meter of 2 m length,
without couplings attached, shall not be more than that
prescribed in Table 1. For the determination of mass,
sample of the hose shall be conditioned at 27 ± 2°C and
65 ± 5 percent relative humidity for a period of at least
48 h and then shall be weighed under the same conditions.) |
- |
1000 |
|
Type - 1 = 1000/-, Type - 2 = 1000/-, Type-3 = 1000/- |
| Cl.6.5(For 30 m length of dry hose without couplings, the coil
diameter shall not exceed 45 cm for Type 1, 50 cm for
Type 2 and 55 cm for Type 3.) |
- |
1000 |
|
Type - 1 = 1000/-, Type - 2 = 1000/-, Type-3 = 1000/- |
| Cl.6.6(Each hose length shall be subjected to an internal hydraulic pressure of 23 kgf/cm² in accordance with 8.1 of IS 443
(Part 3) increasing the pressure at the rate not exceeding
10 kgf/cm² per min and maintaining it for 1 min. Within
this 1 min, the hose shall neither develop any leakage or
sweating, nor shall any thread in the jacket break.) |
- |
3000 |
|
Type - 1 = 3000/-, Type - 2 = 3000/-, Type-3 = 3000/- |
| Cl.6.7(A test length of hose, 1 m clear of fittings when
subjected to an internal hydraulic pressure in
accordance with 8.3 of IS 443 (Part 3) while increasing
the pressure at the rate not exceeding 10 kgf/cm2 per
min shall not burst or show leakage before a pressure
of 38 kgf/cm2 is reached) |
- |
3000 |
|
Type - 1 = 3000/-, Type - 2 = 3000/-, Type-3 = 3000/- |
| Cl.6.8(There shall be no sign of leakage or rupture and no thread in the jacket shall break after retaining the internal hydraulic pressure of 23 kgf/cm2 for 30 seconds.) |
- |
3000 |
|
Type - 1 = 3000/-, Type - 2 = 3000/-, Type-3 = 3000/- |
| Cl.6.9(The increase in length shall not exceed 6 percent at an internal hydraulic pressure of 10 kgf/cm2 for 2 minutes.) |
- |
1000 |
|
Type - 1 = 1000/-, Type - 2 = 1000/-, Type-3 = 1000/- |
| Cl.6.10(The increase in diameter shall not be more than 10% at an internal hydraulic pressure of 10 kgf/cm2 for 2 minutes.) |
- |
1000 |
|
Type - 1 = 1000/-, Type - 2 = 1000/-, Type-3 = 1000/- |
| Cl 6.11 (Adhesion (Cl. 6.11.1))(Rate of separation shall not exceed 25 mm/min 1) Cover) |
- |
1000 |
|
Type - 1 = NA, Type - 2 = 1000/-, Type-3 = 1000/- |
| Cl.6.11 Acccleraled Ageing Test (Cl. 6.11.2) - 1)(After ageing, there shall be no tackiness on the surface of lining or the surface of the cover. ) |
- |
3000 |
|
Type - 1 = 3000/-, Type - 2 = 3000/-, Type-3 = 3000/- |
| Cl.6.12(When determined by the method described in Annex C,
the average number of cycles completed before bursting
of three test pieces, shall not be less than the value
specified in Table 2.) |
- |
2500 |
|
Type - 1 = 2500/-, Type - 2 = 2500/-, Type-3 = 2500/- |
| Cl.6.13(When tested in accordance with Annex D, the amount
of moisture absorbed shall not exceed 0.20 kg/m2 for
Type 2 hoses and 0.02 kg/m2 for Type 3 hoses.) |
- |
2500 |
|
Type - 1 = 2500/-, Type - 2 = 2500/-, Type-3 = 2500/- |
| Cl.6.14(When tested by the method described in Annex E, none
of the test samples shall burst at less than 8 s of the
application of the hot cube for Type 2 and 20 s for
Type 3 hose.) |
- |
1500 |
|
Type - 1 = NA, Type - 2 = 1500/-, Type-3 = 1500/- |
| Cl.6.15 (1)(The length shall be laid horizontally and
the central fully immersed portion of the hose shall be
visually examined for any swelling of rubber,
weathering and cracking in the rubber lining) |
- |
2500 |
|
Type - 1 = 2500/-, Type - 2 = 2500/-, Type-3 = 2500/- |
| Cl.6.18(When tested in accordance with Annex H, the pressure
loss per 23 m length shall not exceed the values specified
in Table 3 at the specified flow rate and inlet pressure
(Recommendations for pressure testing of hoses in
service are given at Annex G).) |
- |
3500 |
|
Type - 1 = 3500/-, Type - 2 = 3500/-, Type-3 = 3500/- |
|
31 Dec, 2026 |
- Ozone Resistance test (Cl.6.16), Hot surface rrsistance test (Cl.6.17) |
| 7212 |
Gravitas Laboratories Private Limited, Greater Noida
| 8182606
| IS 733 (1983) |
Specification for wrought aluminium and aluminium alloy bars, rods and sections (For General Engineering Purposes) (Third Revision) |
- |
7000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl. 4(Freedom from Defects) |
- |
200 |
|
- |
| Cl. 5.1, Table 2(0.2 Percent proof stress- IS 1816) |
- |
600 |
|
- |
| Cl. 5.1, Table 2(Tensile Strength- IS 1816) |
- |
800 |
|
- |
| Cl. 5.1, Table 2(Elongation on 50 mm or 5.65√So Gauge Length) |
- |
600 |
|
- |
| Cl. 0.4, 5.1, Table 1(Aluminium- IS 504 or by any other suitable instrumental method) |
- |
200 |
|
- |
| Cl. 0.4, 5.1, Table 1(Copper- IS 504 or by any other suitable instrumental method) |
- |
400 |
|
- |
| Cl. 0.4, 5.1, Table 1(Magnesium- IS 504 or by any other suitable instrumental method) |
- |
400 |
|
- |
| Cl. 0.4, 5.1, Table 1(Silicon- IS 504 or by any other suitable instrumental method) |
- |
400 |
|
- |
| Cl. 0.4, 5.1, Table 1(Iron- IS 504 or by any other suitable instrumental method) |
- |
400 |
|
- |
| Cl. 0.4, 5.1, Table 1(Zinc- IS 504 or by any other suitable instrumental method) |
- |
400 |
|
- |
| Cl. 0.4, 5.1, Table 1(Aluminium- IS 504 or by any other suitable instrumental method) |
- |
400 |
|
- |
| Cl. 0.4, 5.1, Table 1(Titanium and / or other grain refining elements - IS 504 or by any other suitable instrumental method) |
- |
400 |
|
- |
| Cl. 0.4, 5.1, Table 1(Chromium- IS 504 or by any other suitable instrumental method) |
- |
400 |
|
- |
| Cl. 0.4, 5.1, Table 1(Ti+ V- IS 504 or by any other suitable instrumental method) |
- |
400 |
|
- |
| Cl. 0.4, 5.1, Table 1(Total Impurities- IS 504 or by any other suitable instrumental method) |
- |
400 |
|
- |
| Cl. 0.4, 5.1, Table 1(Cr+ Mn- IS 504 or by any other suitable instrumental method) |
- |
400 |
|
- |
| 7(Dimension - IS 3965) |
- |
0 |
|
- |
| Table-1, Clause - 5.1(Copper) |
- |
400 |
|
- |
| Table-1, Clause - 5.1(Iron) |
- |
0 |
|
- |
| Table-1, Clause - 5.1(Magnesium) |
- |
0 |
|
- |
| Table-1, Clause - 5.1(Manganese) |
- |
0 |
|
- |
| Table-1, Clause - 5.1(Titanium) |
- |
0 |
|
- |
| Table-1, Clause - 5.1(Silicon) |
- |
0 |
|
- |
| Table-1, Clause - 5.1(Chromium) |
- |
0 |
|
- |
| Table-1, Clause - 5.1(Zinc) |
- |
0 |
|
- |
|
19 Nov, 2027 |
- - |
| 7213 |
Gravitas Laboratories Private Limited, Greater Noida
| 8182606
| IS 617 (1994) |
Cast aluminium and its alloys - Ingots and castings for general engineering purposes - Specification (Third Revision) |
- |
15000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 7(FREEDOM FROM DEFECTS) |
- |
200 |
|
- |
| 6, Table 2.(MECHANICAL PROPERTIES OF CASTINGS) |
- |
3000 |
|
- |
| 5, Table 1.(Chemical Composition) |
- |
5000 |
|
- |
| 17(Marking) |
- |
500 |
|
- |
| 11(Pressure Test) |
- |
3500 |
|
- |
| 17(Marking) |
- |
500 |
|
- |
| 11(Pressure Test) |
- |
3500 |
|
- |
| 11(Pressure Test - IS 617) |
- |
3500 |
|
- |
| 13(Marking) |
- |
500 |
|
- |
| Table-1, Clause - 5.1(Copper) |
- |
500 |
|
- |
| Table-1, Clause - 5.1(Iron) |
- |
500 |
|
- |
| Table-1, Clause - 5.1(Magnesium) |
- |
500 |
|
- |
| Table-1, Clause - 5.1(Manganese) |
- |
500 |
|
- |
| Table-1, Clause - 5.1(Silicon) |
- |
500 |
|
- |
| 9(TOLERANCES ON DIMENSIONS OF CASTINGS) |
- |
500 |
|
- |
| 6.2(Hardness) |
- |
500 |
|
- |
| Cl. 5(Copper) |
- |
500 |
|
- |
| Cl. 5(Silicon) |
- |
500 |
|
- |
| Cl. 5(Magnesium) |
- |
500 |
|
- |
| Cl. 5(Manganese) |
- |
500 |
|
- |
| Cl. 5(Iron) |
- |
500 |
|
- |
| Cl. 5(Nickel) |
- |
500 |
|
- |
| Cl. 5(Zinc) |
- |
500 |
|
- |
| Cl. 5(Lead) |
- |
500 |
|
- |
| Cl. 5(Tin) |
- |
500 |
|
- |
| Cl. 5(Titanium) |
- |
500 |
|
- |
| Cl. 5(Aluminium) |
- |
500 |
|
- |
| Cl. 5(Chromium) |
- |
500 |
|
- |
| Cl. 5(Titanium) |
- |
500 |
|
- |
| Cl. 5(Other Element each) |
- |
500 |
|
- |
| Cl. 5(Other Element Total) |
- |
500 |
|
- |
| Cl. 5(Bismuth) |
- |
500 |
|
- |
|
19 Nov, 2027 |
- Exclusion: Cl.11 (Pressure Test), Cl.7 (Freedom from Defects) |
| 7214 |
Gravitas Laboratories Private Limited, Greater Noida
| 8182606
| IS 14650 (1999) |
Carbon steel cast billet ingots, billets, blooms and slabs for re-rolling purposes - Specificaation |
- |
8000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 6(Carbon- Relevant parts of IS 228 or any other established instrumental /Chemical method) |
- |
500 |
|
- |
| 6(Manganese- Relevant parts of IS 228 or any other established instrumental /Chemical method) |
- |
500 |
|
- |
| 6(Silicon- Relevant parts of IS 228 or any other established instrumental /Chemical method) |
- |
500 |
|
- |
| 6(Nitrogen- Relevant parts of IS 228 or any other established instrumental /Chemical method) |
- |
500 |
|
- |
| 6(Aluminium- Relevant parts of IS 228 or any other established instrumental /Chemical method) |
- |
500 |
|
- |
| 6(Titanium- Relevant parts of IS 228 or any other established instrumental /Chemical method) |
- |
500 |
|
- |
| 6(Vanadium- Relevant parts of IS 228 or any other established instrumental /Chemical method) |
- |
500 |
|
- |
| 6(Nickel- Relevant parts of IS 228 or any other established instrumental /Chemical method) |
- |
500 |
|
- |
| 6(Chromium- Relevant parts of IS 228 or any other established instrumental /Chemical method) |
- |
500 |
|
- |
| 6(Copper- Relevant parts of IS 228 or any other established instrumental /Chemical method) |
- |
500 |
|
- |
| 6(Molybdenum- Relevant parts of IS 228 or any other established instrumental /Chemical method) |
- |
500 |
|
- |
| 6(Niobium- Relevant parts of IS 228 or any other established instrumental /Chemical method) |
- |
500 |
|
- |
| 9 & 10(Dimensions and Tolerances ) |
- |
200 |
|
- |
| 11(Freedom from Defects ) |
- |
200 |
|
- |
| 12(Macro-examination ) |
- |
500 |
|
- |
| Cl. 6.1(Nitrogen) |
- |
500 |
|
- |
| Cl. 6.1(Niobium) |
- |
500 |
|
- |
| Cl. 6.1(Titanium) |
- |
500 |
|
- |
| Cl. 6.1(Copper) |
- |
500 |
|
- |
| Cl. 6.1(Aluminium) |
- |
500 |
|
- |
| Cl. 6.1(Molybdenum) |
- |
500 |
|
- |
| Cl. 6.1(Chromium) |
- |
500 |
|
- |
| Cl. 6.1(Vanadium) |
- |
500 |
|
- |
| Cl. 6.1(Nickel) |
- |
500 |
|
- |
| Cl. 6.1(Manganese) |
- |
500 |
|
- |
| Cl. 6.1(Silicon) |
- |
500 |
|
- |
| Cl. 6.1(Carbon) |
- |
500 |
|
- |
| 6("Total content of elements
(Cr+Cu+Ni+Mo+P)-IS:228
") |
- |
3000 |
|
- |
| 6(Sulphur + Phosphorus - IS:228) |
- |
1000 |
|
- |
| 6(Micro alloying elements (Nb+V+Ti+B)) |
- |
1000 |
|
- |
| 11.4 (i)(Bend) |
- |
200 |
|
- |
| 11.4 (ii)(Out of Square) |
- |
100 |
|
- |
| 11.4 (iii)(Scarfing pits) |
- |
100 |
|
- |
|
19 Nov, 2027 |
- Exclusion: Cl.12 (Sulphur Print Test) |
| 7215 |
Gravitas Laboratories Private Limited, Greater Noida
| 8182606
| IS 456 (2000) |
Plain and reinforced concrete - Code of practice (Fourth Revision) |
- |
6500 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 5.4-Table-1 (v)-IS: 3025(P-17)(Suspended matter) |
- |
400 |
|
- |
| 5.4-Table-1 (iv)-IS: 3025(P-32)(Chloride) |
- |
400 |
|
- |
| 5.4-Table-1 (iii)-IS: 3025(P-32)(Chloride) |
- |
400 |
|
- |
| 5.4-Table-1 (ii)-IS: 3025(P-24)(Sulphate) |
- |
400 |
|
- |
| 5.4-Table-1 (i)-IS: 3025(P-18)(In-Organic) |
- |
400 |
|
- |
| 5.4-Table-1 (i)-IS: 3025(P-18)(Organic ) |
- |
400 |
|
- |
| 5.4.2-IS: 3025(P-11)(Ph) |
- |
400 |
|
- |
| 5.4-(b)-IS: 3025 (P-23)(Volume of 0.02 N H2SO4 to neutralized 100 ml of water using mixed indicator) |
- |
400 |
|
- |
| 5.4-(a)-IS: 3025 (P-22)(Volume of 0.02 N NaOH to neutralized 100 ml of water using phenolphthalein indicator) |
- |
400 |
|
- |
| Cl 5.4 Table 1 (v)(Suspended Matter) |
- |
400 |
|
- |
| Cl 5.4 Table 1 (iv)(Chloride) |
- |
400 |
|
- |
| Cl 5.4 Table 1 (iii)(Sulphate) |
- |
400 |
|
- |
| Cl 5.4 Table 1 (ii)(Inorganic Solids) |
- |
400 |
|
- |
| Cl 5.4 Table 1 (i)(Organic Solids) |
- |
400 |
|
- |
| Cl 5.4 .2(pH) |
- |
400 |
|
- |
| Cl 5.4 (b)(Alkalinity) |
- |
400 |
|
- |
| Cl 5.4 (a)(Acidity) |
- |
400 |
|
- |
|
19 Nov, 2027 |
- Only from construction water excluding Cl.5.4.1.2 and 5.4.1.3 |
| 7216 |
The Synthetic and Art Silk Mills' Research Association (SASMIRA), MUMBAI
| 7175004
| IS 18739 (2024) |
Textiles Bedsheets Pillow cover and Blanket Cover Specification |
- |
58400 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 3.1, Table-1(Fibre content) |
- |
500 |
|
To be charged for bed sheet |
| 3.1, Table-1(Count of Yarn-Warp) |
- |
400 |
|
To be charged for bed sheet |
| 3.1, Table-1(Count of Yarn-Weft) |
- |
400 |
|
To be charged for bed sheet |
| 3.1, Table-1(Weave) |
- |
400 |
|
To be charged for bed sheet |
| 3.1, Table-1(Ends/cm) |
- |
200 |
|
To be charged for bed sheet |
| 3.1, Table-1(Picks/cm) |
- |
200 |
|
To be charged for bed sheet |
| 3.1, Table-1(Mass g/m2, Min) |
- |
400 |
|
To be charged for bed sheet |
| 3.1, Table-1, (iii)(Tolerance) |
- |
0 |
|
To be charged for bed sheet |
| 3.1, Table-2(Breaking Load on 5 cm × 20 cm Strip (Ravelled Strip Method)-Warpway) |
- |
500 |
|
To be charged for bed sheet |
| 3.1, Table-2(Breaking Load on 5 cm × 20 cm Strip (Ravelled Strip Method)-Weftway) |
- |
500 |
|
To be charged for bed sheet |
| 3.1, Table-2(Tear Strength,-Warpway) |
- |
500 |
|
To be charged for bed sheet |
| 3.1, Table-2(Tear Strength,-Weftway) |
- |
500 |
|
To be charged for bed sheet |
| 3.1, Table-2(Fabric Skew, Percent, Max) |
- |
400 |
|
To be charged for bed sheet |
| 3.1, Table-2(Fabric Bow, Percent, Max) |
- |
400 |
|
To be charged for bed sheet |
| 3.1, Table-2("Dimensional Change, Percent,-
Warpway/Weftway") |
- |
1000 |
|
To be charged for bed sheet |
| 3.1, Table-2(Scouring Loss Percent, Max) |
- |
600 |
|
To be charged for bed sheet |
| 3.1, Table-2(pH Value) |
- |
350 |
|
To be charged for bed sheet |
| 3.1, Table-2(Resistance to Pilling, For 1 000 Cycles, Min) |
- |
400 |
|
To be charged for bed sheet |
| 3.1, Table-3 (i)("Light:
a) Warp direction
b) Weft direction") |
- |
1200 |
|
To be charged for bed sheet |
| 3.1, Table-3 (ii)("Washing:
a) Change in colour
b) Staining of adjacent fabrics") |
- |
400 |
|
To be charged for bed sheet |
| 3.1, Table-3 (iii)(Bleaching: Hypochlorite) |
- |
350 |
|
To be charged for bed sheet |
| 3.1, Table-3 (iv)("Rubbing:
a) Dry
b) Wet") |
- |
250 |
|
To be charged for bed sheet |
| 3.1, Table-3 (v)("Perspiration, acidic and alkaline:
a) Change in colour
b) Staining of adjacent fabrics") |
- |
400 |
|
To be charged for bed sheet |
| 3.2(Fabric Content) |
- |
500 |
|
To be charged for bed sheet |
| 3.3(Freedom from Defects) |
- |
800 |
|
To be charged for bed sheet |
| 3.4(Sewing Thread) |
- |
600 |
|
To be charged for bed sheet |
| 3.5(Hems) |
- |
400 |
|
To be charged for bed sheet |
| 3.6(Sewing) |
- |
400 |
|
To be charged for bed sheet |
| 3.7, Table-4(- Size) |
- |
400 |
|
To be charged for bed sheet |
| 3.7, Table-4(Width,cm) |
- |
400 |
|
To be charged for bed sheet |
| 3.7, Table-4(Length, cm) |
- |
400 |
|
To be charged for bed sheet |
| Cl-3.8(Soil Release Efficiency) |
- |
11500 |
|
To be charged for bed sheet |
| Cl-3.9(Antimicrobial Activity) |
- |
2800 |
|
To be charged for bed sheet |
| Cl-3.10(Whiteness Index) |
- |
750 |
|
To be charged for bed sheet |
| 3.1, Table-1(Fibre content) |
- |
500 |
|
To be charged for pillow cover |
| 3.1, Table-1(Count of Yarn-Warp) |
- |
400 |
|
To be charged for pillow cover |
| 3.1, Table-1(Count of Yarn-Weft) |
- |
400 |
|
To be charged for pillow cover |
| 3.1, Table-1(Weave) |
- |
400 |
|
To be charged for pillow cover |
| 3.1, Table-1(Ends/cm) |
- |
200 |
|
To be charged for pillow cover |
| 3.1, Table-1(Picks/cm) |
- |
200 |
|
To be charged for pillow cover |
| 3.1, Table-1(Mass g/m2, Min) |
- |
400 |
|
To be charged for pillow cover |
| 3.1, Table-1, (iii)(Tolerance) |
- |
0 |
|
To be charged for pillow cover |
| 3.1, Table-2(Breaking Load on 5 cm × 20 cm Strip (Ravelled Strip Method)-Warpway) |
- |
500 |
|
To be charged for pillow cover |
| 3.1, Table-2(Breaking Load on 5 cm × 20 cm Strip (Ravelled Strip Method)-Weftway) |
- |
500 |
|
To be charged for pillow cover |
| 3.1, Table-2(Tear Strength,-Warpway) |
- |
500 |
|
To be charged for pillow cover |
| 3.1, Table-2(Tear Strength,-Weftway) |
- |
500 |
|
To be charged for pillow cover |
| 3.1, Table-2(Fabric Skew, Percent, Max) |
- |
400 |
|
To be charged for pillow cover |
| 3.1, Table-2(Fabric Bow, Percent, Max) |
- |
400 |
|
To be charged for pillow cover |
| 3.1, Table-2("Dimensional Change, Percent,-
Warpway/Weftway") |
- |
500 |
|
To be charged for pillow cover |
| 3.1, Table-2(Scouring Loss Percent, Max) |
- |
600 |
|
To be charged for pillow cover |
| 3.1, Table-2(pH Value) |
- |
350 |
|
To be charged for pillow cover |
| 3.1, Table-2(Resistance to Pilling, For 1 000 Cycles, Min) |
- |
400 |
|
To be charged for pillow cover |
| 3.1, Table-3 (i)("Light:
a) Warp direction
b) Weft direction") |
- |
1200 |
|
To be charged for pillow cover |
| 3.1, Table-3 (ii)("Washing:
a) Change in colour
b) Staining of adjacent fabrics") |
- |
400 |
|
To be charged for pillow cover |
| 3.1, Table-3 (iii)(Bleaching: Hypochlorite) |
- |
350 |
|
To be charged for pillow cover |
| 3.1, Table-3 (iv)("Rubbing:
a) Dry
b) Wet") |
- |
250 |
|
To be charged for pillow cover |
| 3.1, Table-3 (v)("Perspiration, acidic and alkaline:
a) Change in colour
b) Staining of adjacent fabrics") |
- |
400 |
|
To be charged for pillow cover |
| 3.2(Fabric Content) |
- |
500 |
|
To be charged for pillow cover |
| 3.3(Freedom from Defects) |
- |
800 |
|
To be charged for pillow cover |
| 3.4(Sewing Thread) |
- |
600 |
|
To be charged for pillow cover |
| 3.5(Hems) |
- |
400 |
|
To be charged for pillow cover |
| 3.6(Sewing) |
- |
400 |
|
To be charged for pillow cover |
| 3.7, Table-4(- Size) |
- |
400 |
|
To be charged for pillow cover |
| 3.7, Table-4(Width,cm) |
- |
400 |
|
To be charged for pillow cover |
| 3.7, Table-4(Length, cm) |
- |
400 |
|
To be charged for pillow cover |
| Cl-3.8(Soil Release Efficiency) |
- |
11500 |
|
To be charged for pillow cover |
| Cl-3.9(Antimicrobial Activity) |
- |
2800 |
|
To be charged for pillow cover |
| Cl-3.10(Whiteness Index) |
- |
750 |
|
To be charged for pillow cover |
|
14 Dec, 2026 |
- - |
| 7217 |
Bharat Test House Pvt. Ltd. 1668 Sonipat
| 9168306
| IS 13273 (1991) |
Vitreous enamelled inner tanks for storage water heater - specification |
- |
30000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl. 5.3.2.1(1238) |
- |
5000 |
|
- |
| Cl. 5.3.2.1(1238) |
- |
0 |
|
- |
| Cl. 5.3.2.3(13273) |
- |
6000 |
|
- |
| Cl 5.3.2.2(13273) |
- |
6000 |
|
- |
| Cl. 5.3.3(13273) |
- |
500 |
|
- |
| Cl. 5.3.2.2(3972(P-2/Sec-1)) |
- |
0 |
|
- |
| Cl. 5.3.2.2(3972(P-2/Sec-1)) |
- |
0 |
|
- |
| Cl. 5.3.2.2(3972(P-2/Sec-1)) |
- |
0 |
|
- |
| Cl. 5.3.2.2(3972(P-2/Sec-1)) |
- |
0 |
|
- |
| Cl. 5.3.2.5(13273) |
- |
3000 |
|
- |
| Cl. 5.4(13273) |
- |
2500 |
|
- |
| Cl. 5.5(13273) |
- |
5000 |
|
- |
|
26 Jul, 2027 |
- - |
| 7218 |
CIPET, Vijayawada
| 6141334
| IS 13487 (1992) |
Irrigation equipment - Emitters - Specification |
Regulated and unregulated |
5100 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 7.1(Construction and workmanship) |
- |
500 |
|
Nil |
| 7.2(Flow path in emitters) |
- |
500 |
|
Nil |
| 7.3.1(Resistance to Hydrostatic pressure) |
- |
1000 |
|
Nil |
| 7.3.2(Resistance to Hydrostatic pressure) |
- |
0 |
|
Nil |
| 7.3.3(Resistance to Hydrostatic pressure) |
- |
0 |
|
Nil |
| 7.4.1(Emitter Pull Out In-line emitters) |
- |
500 |
|
Nil |
| 7.4.2(Emitter Pull Out On-line emitters) |
- |
0 |
|
Nil |
| 8.1.2(Uniformity of Emission Rate Unregulated emitters) |
- |
1000 |
|
Nil |
| 8.1.2(Uniformity of Emission Rate Unregulated emitters) |
- |
0 |
|
Nil |
| 8.1.3(Uniformity of Emission Rate Regulated emitters) |
- |
0 |
|
Nil |
| 8.1.3(Uniformity of Emission Rate Regulated emitters) |
- |
0 |
|
Nil |
| 8.2.2(Emission rate as a function of inlet pressure Unregulated emitters) |
- |
1000 |
|
Nil |
| 8.2.3(Emission rate as a function of inlet pressure Regulated emitters) |
- |
0 |
|
Nil |
| 8.3(Determination of Emitter Exponent) |
- |
600 |
|
Nil |
| 4(Classification) |
- |
0 |
|
Nil |
| 5.1(Connections) |
- |
0 |
|
Nil |
| 5.2(Emitter Ends) |
- |
0 |
|
Nil |
| 5.3(Materials) |
- |
0 |
|
Nil |
| 6.1(Test Specimens) |
- |
0 |
|
Nil |
| 6.2(Test Conditions) |
- |
0 |
|
Nil |
| 6.3(Accuracy or Measuring Devices) |
- |
0 |
|
Nil |
| 7.1(Construction and Workmanship) |
- |
0 |
|
Nil |
| 7.2(Flow Paths In Emitter) |
- |
0 |
|
Nil |
| 7.3(Resistance to Hydrostatic Pressure) |
- |
0 |
|
Nil |
| 7.4(Emitter Pull-out) |
- |
0 |
|
Nil |
| 7.4.1(In-Line Emitters) |
- |
0 |
|
Nil |
| 7.4.2(On-Line Emitters) |
- |
0 |
|
Nil |
| 8.1(Uniformity of Emission Rate) |
- |
0 |
|
Nil |
| 8.1.1(Number of Test Samples) |
- |
0 |
|
Nil |
| 8.1.2(Unregulated Emitters) |
- |
0 |
|
Nil |
| 8.1.3(Regulated Emitters) |
- |
0 |
|
Nil |
| 8.2(Emission Rate as a Function of Inlet Pressure) |
- |
0 |
|
Nil |
| 8.2.1(Selection of Telt Sample) |
- |
0 |
|
Nil |
| 8.2.2(Unregulated Emttters) |
- |
0 |
|
Nil |
| 8.2.3(Regulated Emitters) |
- |
0 |
|
Nil |
| 8.3(Determiaatlon of Emitter Exponent) |
- |
0 |
|
Nil |
| 9(Marking) |
- |
0 |
|
Nil |
|
06 Jun, 2027 |
- Included w.e.f. 23.08.2024 |
| 7219 |
Ahmedabad Textile Industry's Research Association (ATIRA), Ahmedabad
| 7173002
| IS 16513 (2016) |
Agro textiles “ Insect nets for agriculture and horticulture purposes “ Specification |
- |
21560 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 6/6.1( REQUIREMENTS Dimensions and Mass a) Length) |
- |
200 |
|
- |
| 6/6.1( REQUIREMENTS Dimensions and Mass b) width) |
- |
200 |
|
- |
| 6/6.1( REQUIREMENTS Dimensions and Mass c) Mass gm/m2) |
- |
0 |
|
- |
| 4.2( Netting Fabric) |
- |
200 |
|
- |
| 4/4.1(b) percent on avarage value; and( MATERIAL / HDPE Monofilament Yarn) |
- |
0 |
|
- |
| 4/4.1(a) percent on individual value; and( MATERIAL / HDPE Monofilament Yarn) |
- |
0 |
|
- |
| 4.2( Netting Fabric) |
- |
200 |
|
- |
| 4.2( Netting Fabric) |
- |
200 |
|
- |
| 5.0(types a) Type I — having mesh of 30; b) Type II — having mesh of 40; andc) c) Type III — having mesh of 50) |
- |
200 |
|
- |
| 4/4.1.1/60°C / 95°C( MATERIAL / HDPE Monofilament Yarn) |
- |
1100 |
|
- |
| 4.3( Colour) |
- |
200 |
|
- |
| 6.2(Table-1) |
- |
250 |
|
- |
| 4.1(Linear Density) |
- |
500 |
|
- |
| 4.1.1(Heat Shrinkage) |
- |
900 |
|
- |
| 6.2/2(Ends per Inch) |
- |
150 |
|
- |
| 6.2/2(Picks per Inch) |
- |
150 |
|
- |
| 6.2/3(cover factor) |
- |
900 |
|
- |
| 6.2/4(Breaking strength before U.V. Exposure (MD & TD)) |
- |
450 |
|
- |
| 6.2/5(UV exposure 144 hours (100x65 + 44x40)) |
- |
13860 |
|
- |
| 6.2/5(Breaking strength after U.V. Exposure (MD & TD)) |
- |
450 |
|
- |
| 6.2/6(Bursting Pressure) |
- |
800 |
|
- |
| 6.2/7(Air Permeability @ 50 pa water head pressure) |
- |
650 |
|
- |
|
- |
- Included w.e.f 10.10.2024 |
| 7220 |
Gravitas Laboratories Private Limited, Greater Noida
| 8182606
| IS 6603 (2001) |
Stainless steel bars and flats - Specification (First Revision) |
- |
10000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl. 7.1, 7.2, 7.3 & 13.1 Table 1(Carbon -Established instrumental/ chemical method as agreed to between purchaser and the manufacturer.) |
- |
500 |
|
- |
| Cl. 7.1, 7.2, 7.3 & 13.1 Table 1(Silicon- Established instrumental/ chemical method as agreed to between purchaser and the manufacturer.) |
- |
500 |
|
- |
| Cl. 7.1, 7.2, 7.3 & 13.1 Table 1(Manganese- Established instrumental/ chemical method as agreed to between purchaser and the manufacturer.) |
- |
500 |
|
- |
| Cl. 7.1, 7.2, 7.3 & 13.1 Table 1(Nickel -Established instrumental/ chemical method as agreed to between purchaser and the manufacturer.) |
- |
2500 |
|
- |
| Cl. 7.1, 7.2, 7.3 & 13.1 Table 1(Chromium- Established instrumental/ chemical method as agreed to between purchaser and the manufacturer.) |
- |
500 |
|
- |
| Cl. 7.1, 7.2, 7.3 & 13.1 Table 1(Molybdenum- Established instrumental/ chemical method as agreed to between purchaser and the manufacturer.) |
- |
500 |
|
- |
| Cl. 7.1, 7.2, 7.3 & 13.1 Table 1(Titanium- Established instrumental/ chemical method as agreed to between purchaser and the manufacturer.) |
- |
500 |
|
- |
| Cl. 7.1, 7.2, 7.3 & 13.1 Table 1(Niobium- Established instrumental/ chemical method as agreed to between purchaser and the manufacturer.) |
- |
500 |
|
- |
| Cl. 7.1, 7.2, 7.3 & 13.1 Table 1(Sulphur- Established instrumental/ chemical method as agreed to between purchaser and the manufacturer.) |
- |
500 |
|
- |
| Cl. 7.1, 7.2, 7.3 & 13.1 Table 1(Phosphorus- Established instrumental/ chemical method as agreed to between purchaser and the manufacturer.) |
- |
500 |
|
- |
| Cl. 7.1, 7.2, 7.3 & 13.1 Table 1(Others (Nitrogen)- Established instrumental/ chemical method as agreed to between purchaser and the manufacturer.) |
- |
500 |
|
- |
| 6(Freedom from defects:) |
- |
200 |
|
- |
| 9.1, Table 3(0.2 Percent Proof Stress, MPa) |
- |
750 |
|
- |
| 9.2, Table 3(Tensile Strength, MPa) |
- |
750 |
|
- |
| 9.3, Table 3(Elongation ,Percent) |
- |
750 |
|
- |
| 9.4, Table 3(Annealed Hardness, HB-IS 1500: Pt 1) |
- |
500 |
|
- |
| 9.5, Table 3(Charpy Impact Test, J-IS 1499) |
- |
750 |
|
- |
| 12(Dimensions & Tolerances, mm-IS 6603) |
- |
200 |
|
- |
| 12(Diameter, mm) |
- |
100 |
|
- |
| 12(Out of Round , mm) |
- |
200 |
|
- |
| 12(Length , mm) |
- |
100 |
|
- |
| 12(Variation in Straightness) |
- |
200 |
|
- |
| Cl. 12
Table 9, 11 & 13 (Square Size) |
- |
200 |
|
- |
| Cl. 12
Table 11,13 & 14(Thickness of Flat) |
- |
200 |
|
- |
| Cl. 12
Table 11,13 & 14(Width of Flat) |
- |
200 |
|
- |
| Cl. 12
Table 10 & 13(Hexagonal Size) |
- |
200 |
|
- |
| Cl. 12
Table 9(Out of Square) |
- |
200 |
|
- |
| Cl. 12
Table 10(Maximum Differences in Three Measurements for Hexagons) |
- |
200 |
|
- |
| Cl. 9.3 Table 3(Bend Test) |
- |
200 |
|
- |
| 9.1/Table-3(0.2% proof stress/Yield stress) |
- |
750 |
|
- |
| 12(Diameter) |
- |
100 |
|
- |
| 9.4(Annealed Hardness) |
- |
500 |
|
- |
| Cl 9.1/Table-3(0.2% proof stress/Yield stress) |
- |
750 |
|
- |
| Cl 9.1/Table-3(Tensile strength) |
- |
750 |
|
- |
| Cl 9.1/Table-3(Elongation) |
- |
750 |
|
- |
| Cl12(Diameter) |
- |
100 |
|
- |
| Cl 9.4(Annealed Hardness) |
- |
500 |
|
- |
|
19 Nov, 2027 |
- Exclusion: Cl.4 (Corrosion test) |
| 7221 |
Lauritz Knudsen Switchgear Testing Laboratories, MSW, SEIPL, Mumbai
| 7177626
| IS/IEC 60947 : Part 4 : Sec 1 (2018) |
Low-Voltage switchgear and controlgear : Part 4-1 Contactors and motor starters electromechanical contactors and motor-Starters |
- |
2335000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 8.1.2(Materials) |
- |
0 |
|
NO TEST |
| 8.1.2.1(General materials requirements) |
- |
5000 |
|
- |
| 8.1.2.2(Glow wire testing) |
- |
20000 |
|
- |
| 8.1.2.3(Test based on flammability category) |
- |
20000 |
|
- |
| 8.1.3(Current-carrying parts and their connections) |
- |
10000 |
|
- |
| 8.1.4(Clearances and creepage distances) |
- |
5000 |
|
- |
| 8.1.5.1(Insulation) |
- |
2000 |
|
No Test |
| 8.1.5.2(Direction of movement) |
- |
2000 |
|
No Test |
| 8.1.5.3(Mounting) |
- |
2000 |
|
No Test |
| 8.1.5.4(Protection) |
- |
2000 |
|
No Test |
| 8.1.8(Terminals) |
- |
2000 |
|
No Test |
| 8.1.8.1(General) |
- |
2000 |
|
No Test |
| 8.1.8.2(Terminal identification and marking) |
- |
1000 |
|
- |
| 8.1.9(Additional requirements for equipment provided with a neutral pole) |
- |
1000 |
|
- |
| 8.1.10(Provisions for protective earthing) |
- |
1000 |
|
- |
| 8.1.11(Enclosures for equipment) |
- |
1000 |
|
- |
| 8.1.11.1(Design) |
- |
1000 |
|
No Test |
| 8.1.11.2(Insulation) |
- |
1000 |
|
No Test |
| 8.1.12(Degrees of protection of enclosed equipment) |
- |
30000 |
|
- |
| 8.1.13(Conduit pull-out, torque and bending with metallic conduits) |
- |
25000 |
|
- |
| 8.2.3(Dielectric properties) |
- |
25000 |
|
- |
| 8.2.3.2(Voltage limiting components between circuits) |
- |
25000 |
|
- |
| 9.1.5.2(Environment tests) |
- |
100000 |
|
- |
| 9.3.6.3(Dielectric tests) |
- |
25000 |
|
- |
| M.9.5(Climatic test) |
- |
50000 |
|
- |
| 8.2.4 of IEC 60947-1:2007 (Sequence 5)(Verification of Mechanical properties of terminals) |
- |
30000 |
|
- |
| Annex C of IEC 60947-1:2007 (Sequence 5)(Verification of Degree of protection of enclosed contactors and starters) |
- |
30000 |
|
- |
| M.9.11(Clearance and creepage distances) |
- |
5000 |
|
- |
| P.2.4.2(Test voltage) |
- |
25000 |
|
- |
| P.2.4.3(Application of the test voltage) |
- |
25000 |
|
- |
| 8.2.2(Temperature-rise) |
- |
15000 |
|
- |
| 8.2.2.3(Accessible parts) |
- |
15000 |
|
- |
| 8.2.2.4(Ambient air temperature) |
- |
15000 |
|
- |
| 8.2.2.5(Main circuit) |
- |
15000 |
|
- |
| 8.2.2.6(Control circuits) |
- |
15000 |
|
- |
| 8.2.2.7.1(Uninterrupted and eight-hour duty windings) |
- |
15000 |
|
- |
| 9.3.3.3.2(Measurement of the temperature of parts) |
- |
15000 |
|
- |
| 9.3.3.3.3(Temperature-rise of a part) |
- |
15000 |
|
- |
| 9.3.3.3.4(Temperature-rise of the main circuit) |
- |
15000 |
|
- |
| 9.3.3.3.5(Temperature-rise of control circuits) |
- |
15000 |
|
- |
| 9.3.3.3.6(Temperature-rise of coils and electromagnets) |
- |
15000 |
|
- |
| 9.3.3.3.7(Temperature-rise of auxiliary circuits) |
- |
15000 |
|
- |
| 9.3.3.3.8(Temperature-rise of starting resistors for rheostatic rotor starters) |
- |
15000 |
|
- |
| M.9.4(Thermal cycling test) |
- |
25000 |
|
- |
| 8.1.17(Short-circuit and overload protection of ports) |
- |
45000 |
|
- |
| 8.2.5.1(Performance under short-circuit conditions) |
- |
45000 |
|
- |
| 9.3.4.2.3(Test at the rated conditional short-circuit current Iq) |
- |
45000 |
|
- |
| P.4(Test of MPSD for IT system) |
- |
45000 |
|
- |
| M.9.7(Critical load current test) |
- |
45000 |
|
- |
| Q.5.3(Selectivity determined by test) |
- |
45000 |
|
- |
| 8.2.4.3.1(Mechanical durability) |
- |
90000 |
|
- |
| 8.2.4.3.2(Electrical durability) |
- |
140000 |
|
- |
| 9.2.2(Electrical performance of screwless-type clamping units) |
- |
140000 |
|
- |
| 9.3.3.6(Operational performance capability) |
- |
70000 |
|
- |
| 9.3.6.4(Mechanical operation tests of a MPSD) |
- |
90000 |
|
- |
| P.2.3(Verification of operational performance capability) |
- |
40000 |
|
- |
| 8.2.4.4(Overload current withstand capability of contactors) |
- |
25000 |
|
- |
| 9.3.5(Overload current withstand capability of contactors) |
- |
25000 |
|
- |
| 8.2.4.5(Coil power consumption) |
- |
15000 |
|
- |
| 8.2.4.6(Pole impedance) |
- |
10000 |
|
- |
| 9.3.3.2.1.2(Coil power consumption) |
- |
10000 |
|
- |
| 9.3.3.2.1.3(Pole impedance) |
- |
10000 |
|
- |
| 9.3.3.2.2(Relays and releases) |
- |
5000 |
|
- |
| 9.3.3.3.1(Ambient air temperature) |
- |
15000 |
|
- |
| 8.1.14(Limited energy source) |
- |
1000 |
|
- |
| 8.1.14.1(General) |
- |
1000 |
|
- |
| 8.1.14.2(Limited energy source with galvanic separation) |
- |
1000 |
|
- |
| 8.1.14.3(Limited energy source with current limiting impedance) |
- |
1000 |
|
- |
| 8.1.15(Stored charge energy circuit) |
- |
1000 |
|
- |
| 8.1.16(Fault and abnormal conditions) |
- |
1000 |
|
- |
| 8.2(Performance requirements) |
- |
20000 |
|
- |
| 8.2.1(Operating conditions) |
- |
45000 |
|
- |
| 8.2.1.1.1(General conditions) |
- |
5000 |
|
- |
| 8.2.1.2(Limits of operation of contactors and power-operated starters) |
- |
5000 |
|
- |
| 8.2.1.3(Limits of operation of under-voltage relays and releases) |
- |
5000 |
|
- |
| 8.2.1.4(Limits of operation of shunt-coil operated releases (shunt trip)) |
- |
5000 |
|
- |
| 8.2.1.5(Limits of operation of current sensing relays and releases) |
- |
5000 |
|
- |
| 8.2.1.5.1(Limits of operation of time-delay overload relays when all poles are energized) |
- |
5000 |
|
- |
| 8.2.1.5.1.1(General tripping requirements of overload relays) |
- |
15000 |
|
- |
| 8.2.1.5.1.2(Thermal memory test verification) |
- |
15000 |
|
- |
| 8.2.1.5.2(Limits of operation of three-pole time-delay overload relays energized on two poles) |
- |
5000 |
|
- |
| 8.2.1.5.3(Limits of operation of instantaneous magnetic overload relays) |
- |
5000 |
|
- |
| 8.2.1.5.4(Limits of operation of under-current relays and releases for automatic change over) |
- |
5000 |
|
- |
| 8.2.1.5.4.1(Limits of operation of under-current relays) |
- |
5000 |
|
- |
| 8.2.1.5.4.2(Limits of operation of automatic change over by under-current relays) |
- |
5000 |
|
- |
| 9.2.3(Ageing test for screwless-type clamping unit) |
- |
10000 |
|
- |
| 9.3.3.2(Operating limits) |
- |
20000 |
|
- |
| 9.3.6.2(Operation and operating limits) |
- |
20000 |
|
- |
| F.7.2(Tests on products in a new condition) |
- |
20000 |
|
- |
| F.7.3(Test after conventional operational performance) |
- |
20000 |
|
- |
| H.3(Limits of operation of control functions) |
- |
5000 |
|
- |
| H.4(Test of the control functions) |
- |
15000 |
|
- |
| 8.3(Electromagnetic compatibility (EMC)) |
- |
20000 |
|
NOT IN NABL SCOPE |
| 8.3.2(Immunity) |
- |
20000 |
|
NOT IN NABL SCOPE |
| 8.3.3(Emission) |
- |
20000 |
|
NOT IN NABL SCOPE |
| 9.2.4(Limited energy source test) |
- |
5000 |
|
- |
| 9.2.5(Breakdown of components) |
- |
5000 |
|
- |
| 9.2.5.2(Breakdown of components test) |
- |
5000 |
|
- |
| 9.4.2(Immunity) |
- |
20000 |
|
NOT IN NABL SCOPE |
| 9.4.2.2(Electrostatic discharge) |
- |
20000 |
|
NOT IN NABL SCOPE |
| 9.4.2.3(Radiated radio-frequency electromagnetic field) |
- |
20000 |
|
NOT IN NABL SCOPE |
| 9.4.2.4(Conducted disturbances induced by radio-frequency fields) |
- |
20000 |
|
NOT IN NABL SCOPE |
| 9.4.2.5(Electrical fast transient/bursts) |
- |
20000 |
|
NOT IN NABL SCOPE |
| 9.4.2.6(Surges) |
- |
20000 |
|
NOT IN NABL SCOPE |
| 9.4.2.7(Power frequency magnetic field) |
- |
20000 |
|
- |
| 9.4.2.8(Voltage dips and short-time interruptions) |
- |
20000 |
|
NOT IN NABL SCOPE |
| 9.4.2.9(Harmonics in the supply) |
- |
20000 |
|
NOT IN NABL SCOPE |
| 9.4.3(Emission) |
- |
20000 |
|
NOT IN NABL SCOPE |
| M.8.3(Electromagnetic compatibility (EMC)) |
- |
20000 |
|
NOT IN NABL SCOPE |
| N.3.2(Touch current measurement) |
- |
5000 |
|
- |
| 8.2.4.7(Ability of a MPSD to make and break under short-circuit conditions) |
- |
45000 |
|
- |
| 8.2.5.3(Co-ordination test between AC-3e rated starter and associated SCPD) |
- |
45000 |
|
- |
| 8.2.5.4(Co-ordination between a MPSD and another short-circuit protective device) |
- |
45000 |
|
- |
| 9.3.4.2.2(prospective current) |
- |
1000 |
|
- |
| 8.1.2(Materials) |
- |
0 |
|
NO TEST |
| 8.1.2.1(General materials requirements) |
- |
5000 |
|
- |
| 8.1.2.2(Glow wire testing) |
- |
20000 |
|
- |
| 8.1.2.3(Test based on flammability category) |
- |
20000 |
|
- |
| 8.1.3(Current-carrying parts and their connections) |
- |
20000 |
|
- |
| 8.1.4(Clearances and creepage distances) |
- |
5000 |
|
- |
| 8.1.5.1(Insulation) |
- |
2000 |
|
NO TEST |
| 8.1.5.2(Direction of movement) |
- |
2000 |
|
NO TEST |
| 8.1.5.3(Mounting) |
- |
2000 |
|
NO TEST |
| 8.1.5.4(Protection) |
- |
2000 |
|
NO TEST |
| 8.1.8(Terminals) |
- |
2000 |
|
NO TEST |
| 8.1.8.1(General) |
- |
2000 |
|
NO TEST |
| 8.1.8.2(Terminal identification and marking) |
- |
1000 |
|
- |
| 8.1.9(Additional requirements for equipment provided with a neutral pole) |
- |
1000 |
|
- |
| 8.1.10(Provisions for protective earthing) |
- |
1000 |
|
- |
| 8.1.11(Enclosures for equipment) |
- |
1000 |
|
- |
| 8.1.11.1(Design) |
- |
2000 |
|
- |
| 8.1.11.2(Insulation) |
- |
2000 |
|
- |
| 8.1.12(Degrees of protection of enclosed equipment) |
- |
30000 |
|
- |
| 8.1.13(Conduit pull-out, torque and bending with metallic conduits) |
- |
25000 |
|
- |
| 8.2.3(Dielectric properties) |
- |
25000 |
|
- |
| 8.2.3.2(Voltage limiting components between circuits) |
- |
25000 |
|
- |
| 9.1.5.2(Environment tests) |
- |
100000 |
|
- |
| 9.3.6.3(Dielectric tests) |
- |
25000 |
|
- |
| M.9.5(Climatic test) |
- |
50000 |
|
- |
| 8.2.4 of IEC 60947-1:2007 (Sequence 5)(Verification of Mechanical properties of terminals) |
- |
30000 |
|
- |
| Annex C of IEC 60947-1:2007 (Sequence 5)(Verification of Degree of protection of enclosed contactors and starters) |
- |
30000 |
|
- |
| M.9.11(Clearance and creepage distances) |
- |
5000 |
|
- |
| P.2.4.2(Test voltage) |
- |
25000 |
|
- |
| P.2.4.3(Application of the test voltage) |
- |
25000 |
|
- |
| 8.2.2(Temperature-rise) |
- |
15000 |
|
- |
| 8.2.2.3(Accessible parts) |
- |
15000 |
|
- |
| 8.2.2.4(Ambient air temperature) |
- |
15000 |
|
- |
| 8.2.2.5(Main circuit) |
- |
15000 |
|
- |
| 8.2.2.6(Control circuits) |
- |
15000 |
|
- |
| 8.2.2.7.1(Uninterrupted and eight-hour duty windings) |
- |
15000 |
|
- |
| 9.3.3.3.2(Measurement of the temperature of parts) |
- |
15000 |
|
- |
| 9.3.3.3.3(Temperature-rise of a part) |
- |
15000 |
|
- |
| 9.3.3.3.4(Temperature-rise of the main circuit) |
- |
15000 |
|
- |
| 9.3.3.3.5(Temperature-rise of control circuits) |
- |
15000 |
|
- |
| 9.3.3.3.6(Temperature-rise of coils and electromagnets) |
- |
15000 |
|
- |
| 9.3.3.3.7(Temperature-rise of auxiliary circuits) |
- |
15000 |
|
- |
| 9.3.3.3.8(Temperature-rise of starting resistors for rheostatic rotor starters) |
- |
15000 |
|
- |
| M.9.4(Thermal cycling test) |
- |
25000 |
|
- |
| 8.1.17(Short-circuit and overload protection of ports) |
- |
45000 |
|
- |
| 8.2.5.1(Performance under short-circuit conditions) |
- |
45000 |
|
- |
| 9.3.4.2.3(Test at the rated conditional short-circuit current Iq) |
- |
45000 |
|
- |
| P.4(Test of MPSD for IT system) |
- |
45000 |
|
- |
| M.9.7(Critical load current test) |
- |
45000 |
|
- |
| Q.5.3(Selectivity determined by test) |
- |
45000 |
|
- |
| 8.2.4.3.1(Mechanical durability) |
- |
90000 |
|
- |
| 8.2.4.3.2(Electrical durability) |
- |
140000 |
|
- |
| 9.2.2(Electrical performance of screwless-type clamping units) |
- |
140000 |
|
- |
| 9.3.3.6(Operational performance capability) |
- |
70000 |
|
- |
| 9.3.6.4(Mechanical operation tests of a MPSD) |
- |
90000 |
|
- |
| P.2.3(Verification of operational performance capability) |
- |
40000 |
|
- |
| 8.2.4.4(Overload current withstand capability of contactors) |
- |
25000 |
|
- |
| 9.3.5(Overload current withstand capability of contactors) |
- |
25000 |
|
- |
| 8.2.4.5(Coil power consumption) |
- |
15000 |
|
- |
| 8.2.4.6(Pole impedance) |
- |
10000 |
|
- |
| 9.3.3.2.1.2(Coil power consumption) |
- |
15000 |
|
- |
| 9.3.3.2.1.3(Pole impedance) |
- |
10000 |
|
- |
| 9.3.3.2.2(Relays and releases) |
- |
5000 |
|
- |
| 9.3.3.3.1(Ambient air temperature) |
- |
15000 |
|
- |
| 8.1.14(Limited energy source) |
- |
1000 |
|
- |
| 8.1.14.1(General) |
- |
1000 |
|
- |
| 8.1.14.2(Limited energy source with galvanic separation) |
- |
1000 |
|
- |
| 8.1.14.3(Limited energy source with current limiting impedance) |
- |
1000 |
|
- |
| 8.1.15(Stored charge energy circuit) |
- |
1000 |
|
- |
| 8.1.16(Fault and abnormal conditions) |
- |
1000 |
|
- |
| 8.2(Performance requirements) |
- |
1000 |
|
- |
| 8.2.1(Operating conditions) |
- |
45000 |
|
- |
| 8.2.1.1.1(General conditions) |
- |
5000 |
|
- |
| 8.2.1.2(Limits of operation of contactors and power-operated starters) |
- |
5000 |
|
- |
| 8.2.1.3(Limits of operation of under-voltage relays and releases) |
- |
5000 |
|
- |
| 8.2.1.4(Limits of operation of shunt-coil operated releases (shunt trip)) |
- |
5000 |
|
- |
| 8.2.1.5(Limits of operation of current sensing relays and releases) |
- |
5000 |
|
- |
| 8.2.1.5.1(Limits of operation of time-delay overload relays when all poles are energized) |
- |
5000 |
|
- |
| 8.2.1.5.1.1(General tripping requirements of overload relays) |
- |
15000 |
|
- |
| 8.2.1.5.1.2(Thermal memory test verification) |
- |
15000 |
|
- |
| 8.2.1.5.2(Limits of operation of three-pole time-delay overload relays energized on two poles) |
- |
5000 |
|
- |
| 8.2.1.5.3(Limits of operation of instantaneous magnetic overload relays) |
- |
5000 |
|
- |
| 8.2.1.5.4(Limits of operation of under-current relays and releases for automatic change over) |
- |
5000 |
|
- |
| 8.2.1.5.4.1(Limits of operation of under-current relays) |
- |
5000 |
|
- |
| 8.2.1.5.4.2(Limits of operation of automatic change over by under-current relays) |
- |
5000 |
|
- |
| 9.2.3(Ageing test for screwless-type clamping unit) |
- |
10000 |
|
- |
| 9.3.3.2(Operating limits) |
- |
5000 |
|
- |
| 9.3.6.2(Operation and operating limits) |
- |
20000 |
|
- |
| F.7.2(Tests on products in a new condition) |
- |
20000 |
|
- |
| F.7.3(Test after conventional operational performance) |
- |
20000 |
|
- |
| H.3(Limits of operation of control functions) |
- |
5000 |
|
- |
| H.4(Test of the control functions) |
- |
15000 |
|
- |
| 8.3(Electromagnetic compatibility (EMC)) |
- |
20000 |
|
NOT IN NABL SCOPE |
| 8.3.2(Immunity) |
- |
20000 |
|
NOT IN NABL SCOPE |
| 9.2.4(Limited energy source test) |
- |
5000 |
|
- |
| 9.2.5(Breakdown of components) |
- |
5000 |
|
- |
| 9.2.5.2(Breakdown of components test) |
- |
5000 |
|
- |
| 9.4.2(Immunity) |
- |
20000 |
|
NOT IN NABL SCOPE |
| 9.4.2.2(Electrostatic discharge) |
- |
20000 |
|
NOT IN NABL SCOPE |
| 9.4.2.3(Radiated radio-frequency electromagnetic field) |
- |
20000 |
|
NOT IN NABL SCOPE |
| 9.4.2.5(Electrical fast transient/bursts) |
- |
20000 |
|
NOT IN NABL SCOPE |
| 9.4.2.6(Surges) |
- |
20000 |
|
NOT IN NABL SCOPE |
| 9.4.2.7(Power frequency magnetic field) |
- |
20000 |
|
NOT IN NABL SCOPE |
| 9.4.2.8(Voltage dips and short-time interruptions) |
- |
20000 |
|
NOT IN NABL SCOPE |
| 9.4.2.9(Harmonics in the supply) |
- |
20000 |
|
NOT IN NABL SCOPE |
| M.8.3(Electromagnetic compatibility (EMC)) |
- |
20000 |
|
NOT IN NABL SCOPE |
| N.3.2(Touch current measurement) |
- |
5000 |
|
- |
| 8.2.4.7(Ability of a MPSD to make and break under short-circuit conditions) |
- |
45000 |
|
- |
| 8.2.5.3(Co-ordination test between AC-3e rated starter and associated SCPD) |
- |
45000 |
|
- |
| 8.2.5.4(Co-ordination between a MPSD and another short-circuit protective device) |
- |
45000 |
|
- |
| 9.3.4.2.2(prospective current) |
- |
1000 |
|
- |
|
11 Apr, 2027 |
- Included w.e.f. 17.09.2024
Exclusion: Cl.9.4.3 (Emission), Cl.8.3.3 (Emission), Cl.9.4.2.4 (Conducted disturbances induced by radio-frequency fields) |
| 7222 |
Gravitas Laboratories Private Limited, Greater Noida
| 8182606
| IS 210 (2009) |
Grey iron castings - Specification (First Revision) |
- |
6500 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 6(Chemical Composition(chemical
composition shall be as agreed to between the
purchaser and the manufacturer.)) |
- |
1000 |
|
- |
| 7.1(WORKMANSHIP AND FINISH) |
- |
200 |
|
- |
| 10.1(FREEDOM FROM DEFECTS) |
- |
200 |
|
- |
| 10.2(FREEDOM FROM DEFECTS) |
- |
200 |
|
- |
| 13(SIZE OF TEST BARS-Diameter) |
- |
100 |
|
- |
| 13(SIZE OF TEST BARS-Length) |
- |
100 |
|
- |
| 15, Table 3(TENSIL.E TEST- IS 1608 Part1 ) |
- |
750 |
|
- |
| 16, Table 3(Hardness Test) |
- |
500 |
|
- |
| 6(Chemical Composition(chemical
composition shall be as agreed to between the
purchaser and the manufacturer.)) |
- |
1000 |
|
- |
| 7.1(WORKMANSHIP AND FINISH) |
- |
200 |
|
- |
| 10.1(FREEDOM FROM DEFECTS) |
- |
200 |
|
- |
| 10.2(FREEDOM FROM DEFECTS) |
- |
200 |
|
- |
| 13(SIZE OF TEST BARS-Diameter) |
- |
100 |
|
- |
| 13(SIZE OF TEST BARS-Length) |
- |
100 |
|
- |
| 15, Table 3(TENSIL.E TEST- IS 1608 Part1 ) |
- |
750 |
|
- |
| 16, Table 3(Hardness Test) |
- |
500 |
|
- |
| 9(Microstructure) |
- |
500 |
|
- |
| 9(Microstructure) |
- |
500 |
|
- |
|
19 Nov, 2027 |
- Exclusion: Cl.17 (Transverse), Cl.18 (Hydrostatic) |
| 7223 |
IDMA LABORATORIES LIMITED, PANCHKULA
| 9123236
| IS 14364 (2024) |
Quaternary Ammonium Compound Based Surface Cleaner, Liquid � Specification ( First Revision ) |
- |
25800 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl-4.1(Description) |
- |
800 |
|
Total testing charges including Keeping Quality are Rs. 25,800/-
Testing charges excluding Keeping Quality are Rs. 12,900/- |
| Cl-4.3(Odour) |
- |
800 |
|
- |
| Cl-4.4(Colour) |
- |
800 |
|
- |
| Cl-4.5(Stability on Dilution) |
- |
1500 |
|
- |
| Cl-4.6(Cleaning Property) |
- |
1500 |
|
- |
| Cl-4.7(Applicability) |
- |
1500 |
|
- |
| Cl-4.8(Keeping Quality) |
- |
12900 |
|
- |
| Cl-4.8 & 4.9, Table-1 (i)(Total non-volatile matter, percent by mass, Min) |
- |
2000 |
|
- |
| Cl-4.8 & 4.9, Table-1 (ii)(pH) |
- |
1500 |
|
- |
| Cl-4.8 & 4.9, Table-1 (iii)(QAC content, percent by mass, Min) |
- |
2000 |
|
- |
| Cl-4.2(Composition) |
- |
500 |
|
- |
| Cl-6(Marking) |
- |
0 |
|
NA |
|
31 Dec, 2026 |
- Included w.e.f. 12.09.2024 |
| 7224 |
CIPET, Hajipur
| 5118334
| IS 17399 (2020) |
Textiles - Polypropylene ( PP )/ High Density Polyethylene ( HDPE ) Laminated Woven Sacks for Mail Sorting, Storage, Transport and Distribution - Specification |
- |
42280 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 5.1(MANUFACTURE - Raw Materials) |
- |
1050 |
|
25% discount for BIS. |
| 5.2(MANUFACTURE - Fabric for PP tapes & for HDPE tapes) |
- |
1000 |
|
Fabric Construction - Rs 500
Tape Width - Rs 500
25% discount for BIS. |
| 5.2- Table 1- i)("REQUIREMENTS - Inside dimensions
a) Bottom panel (L × W), mm b) Open top (L × W), mm c) Height (H), mm") |
- |
500 |
|
Width of the Tape - Rs 500
25% discount for BIS. |
| 5.2- Table 1- ii)(REQUIREMENTS - Ends per dm) |
- |
500 |
|
25% discount for BIS. |
| 5.2- Table 1- iii)(REQUIREMENTS - Picks per dm) |
- |
500 |
|
25% discount for BIS. |
| 5.2- Table 1- iv)(REQUIREMENTS - Mass of laminated sack, g) |
- |
500 |
|
25% discount for BIS. |
| 5.2- Table 1- v)(REQUIREMENTS - Breaking strength of laminated fabric (Cut strip method1)), Min, N2) (kgf) a) Lengthwise b) Widthwise) |
- |
2700 |
|
Avg. breaking strength of Fabric (min)
a. Length wise Rs 1100
b. Width wise Rs 1100
Specimen Preparation - Rs 500
25% discount for BIS. |
| 5.2- Table 1- vi)(REQUIREMENTS - Seam strength of bottom and side panel seam (Cut strip method), Min, N2), (kgf)) |
- |
500 |
|
25% discount for BIS. |
| 5.2- Table 1- vii)("REQUIREMENTS - Elongation at break of fabric, percent:
a) Lengthwise b) Widthwise") |
- |
0 |
|
- |
| 5.2- Table 1- viii)(REQUIREMENTS - Ash content, Max, percent (a) For UV stabilized sacks (b) For non-UV stabilized sacks) |
- |
1200 |
|
Ash Content Rs 1200
25% discount for BIS. |
| 5.3(Lamination) |
- |
2050 |
|
Mass of lamination film Rs 500
Total Mass of Laminated woven fabric Rs 500
Material Identification of lamination Rs 1050
25% discount for BIS. |
| 5.4(Sack Fabrication) |
- |
1500 |
|
Sacks Construction Rs 500
Gromet construction & dimensions Rs 1000
25% discount for BIS. |
| 5.5(Capacity) |
- |
500 |
|
Capacity Rs 500.
25% discount for BIS. |
| 6.1- Table 1- i)(REQUIREMENTS - Inside dimensions a) Bottom panel (L × W), mm b) Open top (L × W), mm c) Height (H), mm) |
- |
1500 |
|
Inside dimensions
a) Bottom panel (L × W), mm Rs 500
b) Open top (L × W), mm Rs 500
c) Height (H), mm Rs 500
25% discount for BIS. |
| 6.1- Table 1- ii)(REQUIREMENTS - Ends per dm) |
- |
0 |
|
- |
| 6.1- Table 1- iii)(REQUIREMENTS - Picks per dm) |
- |
0 |
|
- |
| 6.1- Table 1- iv)(REQUIREMENTS - Mass of laminated sack, g) |
- |
0 |
|
- |
| 6.1- Table 1- v)(REQUIREMENTS - Breaking strength of laminated fabric (Cut strip method1)), Min, N2) (kgf)) |
- |
2200 |
|
"Breaking strength before UV Exposure (min)
a) Length wise " 1100
b) Width wise 1100
25% discount for BIS. |
| 6.1- Table 1- vi)(REQUIREMENTS - Seam strength of bottom and side panel seam (Cut strip method), Min) |
- |
0 |
|
- |
| 6.1- Table 1- vii)(REQUIREMENTS - Elongation at break of fabric, percent a) Lengthwise b) Widthwise) |
- |
0 |
|
- |
| 6.1- Table 1- viii)(REQUIREMENTS - Ash content, Max, percent (a) For UV stabilized sacks (b) For non-UV stabilized sacks) |
- |
0 |
|
- |
| 6.4(UV Resistance Test) |
- |
10180 |
|
UV Resistance(192 hrs)* 8 hour at 60°C Light cycle without condensation, 4 hour at 50°C Dark cycle with condensation, Irradiance 0.63 W/m2 (100 x 60 +92 x40)
Specimen / Conditioning * - Rs 10180 |
| 7(PRINTING, PACKAGING AND MARKING) |
- |
0 |
|
- |
| 8(ATMOSPHERIC CONDITIONS FOR SAMPLE CONDITIONING AND TESTING) |
- |
0 |
|
- |
| Clause 5.1(Raw Materials) |
- |
0 |
|
- |
| "Clause 5.2 Table 1(i)"(Inside dimensions) |
- |
4450 |
|
Identification (Chemical Analysis) Rs 1050
Melt flow rate (MFR) Rs 1100
Linear Density Rs 700
Tanacity Rs 1100
Elongation of the Tape & Thickness of the Tape Rs 500
25% discount for BIS. |
| "Clause 5.2 Table 1(i)"(Inside dimensions) |
- |
1900 |
|
Dimensional Stability (100 °C & 10 min.) Rs 700
Dimensional Stability (125 °C & 10 min.) Rs 700
GSM of Unlaminated fabric Rs 500
25% discount for BIS. |
| "Clause 5.2 Table 1(ii)"(Ends per dm) |
- |
0 |
|
- |
| "Clause 5.2 Table 1(iii)"(Picks per dm) |
- |
0 |
|
- |
| "Clause 5.2 Table 1(iv)"("Mass of laminated
sack, g") |
- |
0 |
|
- |
| "Clause 5.2 Table 1(v)"("Breaking strength of
laminated fabric") |
- |
0 |
|
- |
| "Clause 5.2 Table 1(vi)"(Seam strength of bottom and side panel seam) |
- |
0 |
|
- |
| "Clause 5.2 Table 1(vii)"("Elongation at break
of fabric, percent:") |
- |
0 |
|
- |
| "Clause 5.2 Table 1(viii)"("Ash content, Max,
percent") |
- |
0 |
|
- |
| Clause 5.3(Lamination with a thin film of polypropylene) |
- |
0 |
|
- |
| Clause 5.4(Sack Fabrication) |
- |
3750 |
|
Stitches Separation (Min), Outer stitches (Min) Depth of seam over doubled fold (Min) Rs 500
No Stitches per dm Rs1100
Bottom seam Construction Rs500
Stitching thread material Identification Rs1050
Breaking load of stitching thread Rs1100
25% disc |
| Clause 7.3(Marking on Sacks) |
- |
2000 |
|
Presence of UV stabiliser : Rs 2000
25% discount for BIS. |
| Clause 5.1(Raw Materials) |
- |
0 |
|
- |
| "Clause 5.2 Table 1(i)"(Inside dimensions) |
- |
0 |
|
- |
| "Clause 5.2 Table 1(ii)"(Ends per dm) |
- |
0 |
|
- |
| "Clause 5.2 Table 1(iii)"(Picks per dm) |
- |
0 |
|
- |
| "Clause 5.2 Table 1(iv)"("Mass of laminated
sack, g") |
- |
0 |
|
- |
| "Clause 5.2 Table 1(v)"("Breaking strength of
laminated fabric") |
- |
0 |
|
- |
| "Clause 5.2 Table 1(vi)"(Seam strength of bottom and side panel seam) |
- |
0 |
|
- |
| "Clause 5.2 Table 1(vii)"("Elongation at break
of fabric, percent:") |
- |
2700 |
|
Breaking strength after UV Exposure (min)
a) Length wise " Rs 1100
b) Width wise Rs 1100
Specimen Preparation: Rs 500
25% discount for BIS. |
| "Clause 5.2 Table 1(viii)"("Ash content, Max,
percent") |
- |
0 |
|
- |
| Clause 5.3(Lamination with a thin film of polypropylene) |
- |
0 |
|
- |
| Clause 7.3(Marking on Sacks) |
- |
0 |
|
- |
|
07 Oct, 2028 |
- Included w.e.f. 22.08.2024 |
| 7225 |
CIPET, Hajipur
| 5118334
| IS 16703 (2017) |
Textiles - High density polyethylene (HDPE) polypropylene (PP) woven sacks for packaging of 25 kg polymer materials - Specification |
- |
38230 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 5.1(Mass of Bale) |
- |
500 |
|
25% discount for BIS. |
| 5.2 Table 1(Dimensions) |
- |
500 |
|
25% discount for BIS. |
| 5.2 Table 1(Dimensions) |
- |
2900 |
|
Thickness of the Tape
Width of the Tape
Dimensional Stability (100 °C & 10 min.)
Dimensional Stability (125 °C & 10 min.)
Weight of fabric (unlaminated)
25% discount for BIS. |
| 5.2 Table 1(Dimensions) |
- |
3150 |
|
Tape Width
Mesh size
Identification
Melt flow rate (MFR)
25% discount for BIS. |
| 5.2 Table 1(Dimensions) |
- |
2500 |
|
Linear Density of tape
Tanacity & Elongation
Density of tape Raw Material
25% discount for BIS. |
| 5.2 Table 1(Ends per dm) |
- |
500 |
|
25% discount for BIS. |
| 5.2 Table 1(Picks per dm) |
- |
500 |
|
25% discount for BIS. |
| 5.2 Table 1(Mass of sack, Gusseted type, g - IS 1964) |
- |
1050 |
|
4.1 Raw Material identification Rs 1050
25% discount for BIS. |
| 5.2 Table 1(Average breaking strength of fabric [Ravelled strip
method, 325 mm × 70mm1)] Min, N) (kgf): - IS 1969 (Part 1)) |
- |
2700 |
|
Avg. breaking strength of Fabric & Elongation
Length wise & Width wise
25% discount for BIS. |
| 5.2 Table 1(Average breaking strength of fabric [Ravelled strip
method, 325 mm × 70mm1)] Min, N2) (kgf): - IS 1969 (Part 1)) |
- |
1100 |
|
Minimum breaking strength of Bottom seam
25% discount for BIS. |
| 5.2 Table 1(Breaking strength of bottom seam (Ravelled strip
method), Min, N) (kgf) - IS 9030) |
- |
1600 |
|
Breaking Load of stitching thread
25% discount for BIS. |
| 5.2 Table 1(Elongation at break of fabric (Ravelled strip method),
percent : IS 1969 (Part 1)) |
- |
2700 |
|
Breaking strength of fabric after 192 hrs of UV exposure length wise &Width wise
25% discount for BIS. |
| 5.2 Table 1(Elongation at break of fabric (Ravelled strip method),
percent : IS 1969 (Part 1)) |
- |
0 |
|
Already Included |
| 5.2 Table 1(Drop impact strength) |
- |
1600 |
|
25% discount for BIS. |
| (Clauses 4.2, 5.1, 5.2, 5.3 and 5.4) Table 1 (Ash Content ,a) For UV stabilized sacks) |
- |
1200 |
|
Ash content
25% discount for BIS. |
| (Clauses 4.2, 5.1, 5.2, 5.3 and 5.4) Table 1 (Ash Content ,b) For non- UV stabilized sacks) |
- |
0 |
|
25% discount for BIS. |
| 4.6(Capacity) |
- |
500 |
|
Sacks
25% discount for BIS. |
| 4.3.1(Bottom Seam) |
- |
1500 |
|
1. Snitches Separation (Min)
2. Outer stitches (Min)
3. Depth of seam over doubled fold (Min)
25% discount for BIS. |
| 4.3(Sacks) |
- |
0 |
|
25% discount for BIS. |
| 4.2,5.1,5.2,5.3,5.4(Breaking strenght after U.V. Exposure (Warp/Weft)) |
- |
3550 |
|
Bottom Seam –No Stitches per dm
Stitching thread (Material Identification)
Presence of UV stabiliser in stitching thread
25% discount for BIS. |
| 4.2,5.1,5.2,5.3,5.4,(UV Resistance (192 hrs)(100 x 65+92x40)) |
- |
10180 |
|
Specimen Charge Breaking strength of fabric after 192 hrs of UV exposure[UV Resistance(192 hrs)*8 hour at 60°C Light cycle without condensation, 4 hour at 50°C Dark cycle with condensation,Irradiance 0.63 W/m2 (100 x 60 +92 x40)]
25% discount for BIS. |
| 4.2(Linear Density) |
- |
0 |
|
25% discount for BIS. |
| 4.2(Width of tape) |
- |
0 |
|
Already Included |
|
07 Oct, 2028 |
- Included w.e.f. 22.08.2024 |
| 7226 |
Gravitas Laboratories Private Limited, Greater Noida
| 8182606
| IS 383 (2016) |
Coarse and Fine Aggregate for Concrete - Specification (Third Revision) |
- |
10500 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 5.4.1 (a)(mechanical properties- Aggregate Crushing Value/Ten Percent Fines Value) |
- |
500 |
|
- |
| 5.4.1 (b)(mechanical properties- Aggregate Crushing Value/Ten Percent Fines Value) |
- |
500 |
|
- |
| 5.4.2(a)( Aggregates Impact Value) |
- |
500 |
|
- |
| 5.4.2(b)( Aggregates Impact Value) |
- |
500 |
|
- |
| 5.4.3(a)( Aggregate Abrasion Value) |
- |
500 |
|
- |
| 5.4.3(b)( Aggregate Abrasion Value) |
- |
500 |
|
- |
| 6.1-Table 7(SIZE AND GRADING OF AGGREGATES-Single-Sized Coarse Aggregates-Nominal Size of aggregate) |
- |
500 |
|
- |
| 6.1-Table 7(i)(SIZE AND GRADING OF AGGREGATES-Single-Sized Coarse Aggregates-Percentage Passing through 80 mm sieve ) |
- |
500 |
|
- |
| 6.1-Table 7(ii)(SIZE AND GRADING OF AGGREGATES-Single-Sized Coarse Aggregates-Percentage Passing through 63 mm sieve ) |
- |
500 |
|
- |
| 6.1-Table 7(iii)(SIZE AND GRADING OF AGGREGATES-Single-Sized Coarse Aggregates-Percentage Passing through 40 mm sieve ) |
- |
0 |
|
- |
| 6.1-Table 7(iv)(SIZE AND GRADING OF AGGREGATES-Single-Sized Coarse Aggregates-Percentage Passing through 20 mm sieve ) |
- |
500 |
|
- |
| 6.1-Table 7(v)(SIZE AND GRADING OF AGGREGATES-Single-Sized Coarse Aggregates-Percentage Passing through 16 mm sieve ) |
- |
500 |
|
- |
| 6.1-Table 7(vi)(SIZE AND GRADING OF AGGREGATES-Single-Sized Coarse Aggregates-Percentage Passing through 12.5 mm sieve ) |
- |
500 |
|
- |
| 6.1-Table 7(vii)(SIZE AND GRADING OF AGGREGATES-Single-Sized Coarse Aggregates-Percentage Passing through 10 mm sieve ) |
- |
500 |
|
- |
| 6.1-Table 7(viii)(SIZE AND GRADING OF AGGREGATES-Single-Sized Coarse Aggregates-Percentage Passing through 4.75 mm sieve ) |
- |
500 |
|
- |
| 6.1-Table 7(ix)(SIZE AND GRADING OF AGGREGATES-Single-Sized Coarse Aggregates-Percentage Passing through 2.36 mm sieve ) |
- |
500 |
|
- |
| 6.1.1-Table 8(SIZE AND GRADING OF AGGREGATES- Sizes of Coarse Aggregates for Mass Concrete- Class) |
- |
500 |
|
- |
| 6.1.1-Table 8(SIZE AND GRADING OF AGGREGATES- Sizes of Coarse Aggregates for Mass Concrete- Size) |
- |
500 |
|
- |
| 6.1.1-Table 8(i)(SIZE AND GRADING OF AGGREGATES- Sizes of Coarse Aggregates for Mass Concrete- Percentage Passing through 160 mm Sieve) |
- |
500 |
|
- |
| 6.1.1-Table 8(i)(SIZE AND GRADING OF AGGREGATES- Sizes of Coarse Aggregates for Mass Concrete- Percentage Passing through 80 mm Sieve) |
- |
500 |
|
- |
| 6.1.1-Table 8(ii)(SIZE AND GRADING OF AGGREGATES- Sizes of Coarse Aggregates for Mass Concrete- Percentage Passing through 80 mm Sieve) |
- |
500 |
|
- |
| 6.1.1-Table 8(ii)(SIZE AND GRADING OF AGGREGATES- Sizes of Coarse Aggregates for Mass Concrete- Percentage Passing through 40 mm Sieve) |
- |
500 |
|
- |
| 6.1.1-Table 8(iii)(SIZE AND GRADING OF AGGREGATES- Sizes of Coarse Aggregates for Mass Concrete- Percentage Passing through 40 mm Sieve) |
- |
500 |
|
- |
| 6.1.1-Table 8(iii)(SIZE AND GRADING OF AGGREGATES- Sizes of Coarse Aggregates for Mass Concrete- Percentage Passing through 20 mm Sieve) |
- |
500 |
|
- |
| 6.1.1-Table 8(iv)(SIZE AND GRADING OF AGGREGATES- Sizes of Coarse Aggregates for Mass Concrete- Percentage Passing through 20 mm Sieve) |
- |
500 |
|
- |
| 6.1.1-Table 8(iv)(SIZE AND GRADING OF AGGREGATES- Sizes of Coarse Aggregates for Mass Concrete- Percentage Passing through 4.75 mm Sieve) |
- |
500 |
|
- |
| 6.1.1-Table 8(iv)(SIZE AND GRADING OF AGGREGATES- Sizes of Coarse Aggregates for Mass Concrete- Percentage Passing through 2.36 mm Sieve) |
- |
500 |
|
- |
| 6.2-Table 7(SIZE AND GRADING OF AGGREGATES- Graded Coarse Aggregates-Nominal Size of aggregate) |
- |
500 |
|
- |
| 6.2-Table 7(i)(SIZE AND GRADING OF AGGREGATES- Graded Coarse Aggregates-Percentage Passing through 80 mm sieve) |
- |
500 |
|
- |
| 6.2-Table 7(ii)(SIZE AND GRADING OF AGGREGATES- Graded Coarse Aggregates-Percentage Passing through 63 mm sieve) |
- |
500 |
|
- |
| 6.2-Table 7(iii)(SIZE AND GRADING OF AGGREGATES- Graded Coarse Aggregates-Percentage Passing through 40 mm sieve) |
- |
500 |
|
- |
| 6.2-Table 7(iv)(SIZE AND GRADING OF AGGREGATES- Graded Coarse Aggregates-Percentage Passing through 20 mm sieve) |
- |
500 |
|
- |
| 6.2-Table 7(v)(SIZE AND GRADING OF AGGREGATES- Graded Coarse Aggregates-Percentage Passing through 16 mm sieve) |
- |
500 |
|
- |
| 6.2-Table 7(vi)(SIZE AND GRADING OF AGGREGATES- Graded Coarse Aggregates-Percentage Passing through 12.5 mm sieve) |
- |
500 |
|
- |
| 6.2-Table 7(vii)(SIZE AND GRADING OF AGGREGATES- Graded Coarse Aggregates-Percentage Passing through 10 mm sieve) |
- |
500 |
|
- |
| 6.2-Table 7(viii)(SIZE AND GRADING OF AGGREGATES- Graded Coarse Aggregates-Percentage Passing through 4.75 mm sieve) |
- |
500 |
|
- |
| 6.2-Table 7(ix)(SIZE AND GRADING OF AGGREGATES- Graded Coarse Aggregates-Percentage Passing through 2.36 mm sieve) |
- |
500 |
|
- |
| 6.3-Table 9(SIZE AND GRADING OF AGGREGATES-Fine Aggregate-Grading Zone) |
- |
500 |
|
- |
| 6.3-Table 9(i)(SIZE AND GRADING OF AGGREGATES-Fine Aggregate-Percentage Passing through 10mm Sieve ) |
- |
500 |
|
- |
| 6.3-Table 9(ii)(SIZE AND GRADING OF AGGREGATES-Fine Aggregate-Percentage Passing through 4.75mm Sieve ) |
- |
500 |
|
- |
| 6.3-Table 9(iii)(SIZE AND GRADING OF AGGREGATES-Fine Aggregate-Percentage Passing through 2.36mm Sieve ) |
- |
500 |
|
- |
| 6.3-Table 9(iv)(SIZE AND GRADING OF AGGREGATES-Fine Aggregate-Percentage Passing through 1.18mm Sieve ) |
- |
500 |
|
- |
| 6.3-Table 9(v)(SIZE AND GRADING OF AGGREGATES-Fine Aggregate-Percentage Passing through 600µm Sieve ) |
- |
500 |
|
- |
| 6.3-Table 9(vi)(SIZE AND GRADING OF AGGREGATES-Fine Aggregate-Percentage Passing through 300µm Sieve ) |
- |
500 |
|
- |
| 6.3-Table 9(vii)(SIZE AND GRADING OF AGGREGATES-Fine Aggregate-Percentage Passing through 150µm Sieve ) |
- |
500 |
|
- |
| 6.4-Table 10(SIZE AND GRADING OF AGGREGATES- All-in-Aggregate Grading-Nominal Size ) |
- |
500 |
|
- |
| 6.4-Table 10(i)(SIZE AND GRADING OF AGGREGATES- All-in-Aggregate Grading-Percentage Passing through 80mm Sieve ) |
- |
500 |
|
- |
| 6.4-Table 10(ii)(SIZE AND GRADING OF AGGREGATES- All-in-Aggregate Grading-Percentage Passing through 40mm Sieve ) |
- |
500 |
|
- |
| 6.4-Table 10(iii)(SIZE AND GRADING OF AGGREGATES- All-in-Aggregate Grading-Percentage Passing through 20mm Sieve ) |
- |
500 |
|
- |
| 6.4-Table 10(iv)(SIZE AND GRADING OF AGGREGATES- All-in-Aggregate Grading-Percentage Passing through 4.75mm Sieve ) |
- |
500 |
|
- |
| 6.4-Table 10(v)(SIZE AND GRADING OF AGGREGATES- All-in-Aggregate Grading-Percentage Passing through 600µm Sieve ) |
- |
500 |
|
- |
| 6.4-Table 10(vi)(SIZE AND GRADING OF AGGREGATES- All-in-Aggregate Grading-Percentage Passing through 150µm Sieve ) |
- |
500 |
|
- |
| 5.7-Table-3-(v) IS: 2386 (P-3)(specific gravity(fine aggregate)) |
- |
500 |
|
- |
| 5.7-Table-3-(Iv) IS: 2386 (P-3)(Water absorption (fine aggregate)) |
- |
500 |
|
- |
| 5.7-Table-3-(III) IS:14959 (P-2)(Water soluble chloride content (fine aggregate)) |
- |
500 |
|
- |
| 5.7-Table-3-(II) IS:4032(Total sulphate content (fine aggregate)) |
- |
500 |
|
- |
| 5.6-IS: 2386 (P-7)(Alkali Aggregate Reaction (fine aggregate)) |
- |
500 |
|
- |
| 5.5-IS: 2386 (P-5)(Soundness (fine aggregate)) |
- |
500 |
|
- |
| 5.2- TABLE-2- (Note-3) IS-2386 (P-2)(Mica content (fine aggregate)) |
- |
500 |
|
- |
| 5.2- TABLE-2- (Note-4) IS-2386 (P-2)(Effect of organic impurities on strength of mortar (fine aggregate)) |
- |
500 |
|
- |
| 5.2- TABLE-2- (Note-4) IS-2386 (P-2)(Effect of organic impurities on strength of mortar (fine aggregate)) |
- |
500 |
|
- |
| 5.2- TABLE-2- (Note-4) IS-2386 (P-2)(Organic impurities (fine aggregate)) |
- |
500 |
|
- |
| 5.2- TABLE-2- (vi) IS-2386 (P-2)(Total deleterious material (fine aggregate)) |
- |
500 |
|
- |
| 5.2- TABLE-2- (iii) IS-2386 (P-1)(Material fine aggregater than 75 micron (fine aggregate)) |
- |
500 |
|
- |
| 5.2- TABLE-2- (ii) IS-2386 (P-2)(Clay lumps (fine aggregate )) |
- |
500 |
|
- |
| 5.2- TABLE-2- (i) IS-2386 (P-2)(Coal and Lignite (fine aggregate )) |
- |
500 |
|
- |
| 5.7-Table-3-(v) IS: 2386 (P-3)(specific gravity(coarse aggregate)) |
- |
500 |
|
- |
| 5.7-Table-3-(Iv) IS: 2386 (P-3)(Water absorption (coarse aggregate)) |
- |
500 |
|
- |
| 5.7-Table-3-(III) BN EN: 1744(Water soluble chloride content (coarse aggregate)) |
- |
500 |
|
- |
| 5.7-Table-3-(II) BN EN: 1744(Total sulphate content (coarse aggregate)) |
- |
500 |
|
- |
| 5.6-IS: 2386 (P-7)(Alkali Aggregate Reaction (coarse aggregate)) |
- |
500 |
|
- |
| 5.5-IS: 2386 (P-5)(Soundness (coarse aggregate)) |
- |
500 |
|
- |
| 5.3-IS: 2386 (P-1)(Combined elongation & flakiness index (coarse aggregate)) |
- |
500 |
|
- |
| 5.2- TABLE-2- (vi) IS-2386 (P-2)(Total deleterious material (coarse aggregate)) |
- |
500 |
|
- |
| 5.2- TABLE-2- (iv) IS-2386 (P-2)(Soft fragments (coarse aggregate)) |
- |
500 |
|
- |
| 5.2- TABLE-2- (iii) IS-2386 (P-1)(Material fine aggregater than 75 micron (coarse aggregate)) |
- |
500 |
|
- |
| 5.2- TABLE-2- (ii) IS-2386 (P-2)(Clay lumps (coarse aggregate )) |
- |
500 |
|
- |
| 5.2- TABLE-2- (i) IS-2386 (P-2)(Coal and Lignite (coarse aggregate )) |
- |
500 |
|
- |
| 5.5(Soundness By Magnesium Sulphate) |
- |
500 |
|
- |
| 7.2(Moisture Content) |
- |
500 |
|
- |
| 7.2(Bulking Of Fine Aggregate) |
- |
500 |
|
- |
| 7.2(Bulk Density loose) |
- |
500 |
|
- |
| 7.2(Bulk Density Rodded) |
- |
500 |
|
- |
| 5.5(Soundness By Magnesium Sulphate) |
- |
500 |
|
- |
| 7.2(Moisture Content) |
- |
500 |
|
- |
| 7.2(Bulk Density loose) |
- |
500 |
|
- |
| 7.2(Bulk Density Rodded) |
- |
500 |
|
- |
| 5.3(Elongation Index) |
- |
500 |
|
- |
| 5.3(Flakiness Index) |
- |
500 |
|
- |
| 5.6(Alkali Agregate Reaction ) |
- |
500 |
|
- |
| 5.7 table 3(WaterAbsorption) |
- |
500 |
|
- |
| 5.7 table 3(Specific Gravity) |
- |
500 |
|
- |
| 5.3(Flakiness & Elongation) |
- |
500 |
|
- |
| 5.5 Na2so4/5.5.1 Maso4/5.5.1 (Soundness) |
- |
500 |
|
- |
| 5.5 Na2so4/5.5.1 Maso4/5.5.1 (Soundness) |
- |
500 |
|
- |
| 5.2 (5.2.2, 5.2.1, 5.2.3, shale table-2 ) (Deleterious material (Clay lumps, coal & lignite, material finer than 75 micron IS sieve, Soft fragments,shale)) |
- |
500 |
|
- |
| Clause 5.7- Table 3 (i) (TotalAlkali content as Na2O equivalent ) |
- |
500 |
|
- |
| Clause 5.6(Nature of Aggregate) |
- |
500 |
|
- |
| Clause 5.6(Dissolved Silica) |
- |
500 |
|
- |
| Clause 5.6(Reduction in Alkalinity) |
- |
500 |
|
- |
| Clause 5.1(General) |
- |
500 |
|
- |
| Clause 5.1(General) |
- |
500 |
|
- |
|
19 Nov, 2027 |
- Only for aggregates from natural sources |
| 7227 |
CIPET, Hajipur
| 5118334
| IS 16709 (2017) |
Textiles - Polypropylene (PP) woven, laminated, block bottom valve sacks for packaging of 50 kg cement - Specification |
- |
24150 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4.1.1(Sack Length) |
- |
500 |
|
25% Discount for BIS. |
| 4.1.2(Sack Width) |
- |
0 |
|
25% Discount for BIS. |
| 4.1.3(Top Closure Width and Bottom Closure Width) |
- |
500 |
|
Fabric Construction.25% Discount for BIS. |
| 4.1.4(Patch Length) |
- |
0 |
|
- |
| 4.1.5(Patch Height) |
- |
0 |
|
- |
| 4.1.6(Length of Valve) |
- |
2150 |
|
Identification (Chemical Analysis)
Melt flow rate (MFR)
25% Discount for BIS. |
| 4.1.7(Width of Valve Sleeve) |
- |
1100 |
|
Tanacity
Elongation of the Tape
25% Discount for BIS. |
| 4.1.8(Length of Valve Sleeve) |
- |
1500 |
|
Sacks Construction
Construction of top & bottom closures
Filling valves construction
25% Discount for BIS. |
| 5.1(Raw Material) |
- |
1050 |
|
25% Discount for BIS. |
| 5.2(Fabric) |
- |
2400 |
|
Thickness of the Tape
Width of the Tape
Dimensional Stability (100 °C & 10 min.)
Dimensional Stability (125 °C & 10 min.)
25% Discount for BIS. |
| 5.2(Tape density and width) |
- |
700 |
|
Linear Density.25% Discount for BIS. |
| 5.4(Lamination for PP) |
- |
1550 |
|
mass of lamination film & Material Identification of lamination .25% Discount for BIS. |
| 5.4(Lamination for LDPE) |
- |
1000 |
|
Total mass of laminated woven fabric& Overhung width. 25% Discount for BIS. |
| 6.1(Mass of Bale) |
- |
500 |
|
25% Discount for BIS. |
| 6.2.1(Breaking Strength and Elongation at Break of Fabric) |
- |
2700 |
|
Length Wise (Rs 1100) & Width Wise (Rs 1100) Specimen Preparation (Rs 500). 25% Discount for BIS. |
| 6.2.2(Weld Strength of Top and Bottom Closures) |
- |
1100 |
|
25% Discount for BIS. |
| 6.3(Drop Impact Testing of Filled Sacks) |
- |
1100 |
|
25% Discount for BIS. |
| 6.4(Ash Content) |
- |
1200 |
|
25% Discount for BIS. |
| 6.5(Air Permeability) |
- |
1100 |
|
25% Discount for BIS. |
| 8(Atomspheric Conditions for Conditioning and Testing) |
- |
500 |
|
Perforation Construction.25% Discount for BIS. |
| Cl-5.6(Capacity) |
- |
500 |
|
25% Discount for BIS. |
| Cl- 6.6, Table.-1 (ii)(Ends per dm) |
- |
500 |
|
25% Discount for BIS. |
| Cl-6.6, Table-1 (iii)(Picks per dm) |
- |
500 |
|
25% Discount for BIS. |
| Cl.6.6, Table-1 (vii)(Elongation at break of fabric) |
- |
2000 |
|
Dimensions: Sack, Closure, Patch and Valve, in mm.
25% Discount for BIS. |
|
07 Oct, 2028 |
- Included w.e.f. 22.08.2024 |
| 7228 |
Bharat Test House Pvt. Ltd. 1668 Sonipat
| 9168306
| IS 14261 (1995) |
Transmission devices - V - Belts endless narrowv - Belts for industrial use - Specification |
V - Belts |
35500 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl 4(Material And Workmanship) |
- |
5000 |
|
- |
| Cl 5.1(Cross-Section Dimensions) |
- |
13000 |
|
- |
| Cl 5.2(Cross-Section Dimensions) |
- |
13000 |
|
- |
| Cl 6(DESIGNATION) |
- |
1000 |
|
- |
| Cl 7(Length Measurement And Tolerances) |
- |
7500 |
|
- |
| Cl 7.2.1(Determination of Pitch Length) |
- |
5000 |
|
- |
| Cl 7.2.2(Determination of Pitch Length) |
- |
3500 |
|
- |
| Cl 7.2.3(Determination of Pitch Length) |
- |
0 |
|
- |
| Cl 7.3(Matched Belts) |
- |
0 |
|
- |
| Cl 4(Material And Workmanship) |
- |
0 |
|
- |
| Cl 5.1(Cross-Section Dimensions) |
- |
0 |
|
- |
| Cl 5.2(Cross-Section Dimensions) |
- |
0 |
|
- |
| Cl 6(DESIGNATION) |
- |
0 |
|
- |
| Cl 7(Length Measurement And Tolerances) |
- |
0 |
|
- |
| Cl 7.2.1(Determination of Pitch Length) |
- |
0 |
|
- |
| Cl 7.2.2(Determination of Pitch Length) |
- |
0 |
|
- |
| Cl 7.2.3(Determination of Pitch Length) |
- |
0 |
|
- |
| Cl 7.3(Matched Belts) |
- |
0 |
|
- |
| Cl 4(Material And Workmanship) |
- |
0 |
|
- |
| Cl 5.1(Cross-Section Dimensions) |
- |
0 |
|
- |
| Cl 5.2(Cross-Section Dimensions) |
- |
0 |
|
- |
| Cl 6(DESIGNATION) |
- |
0 |
|
- |
| Cl 7(Length Measurement And Tolerances) |
- |
0 |
|
- |
| Cl 7.2.1(Determination of Pitch Length) |
- |
0 |
|
- |
| Cl 7.2.2(Determination of Pitch Length) |
- |
0 |
|
- |
| Cl 7.2.3(Determination of Pitch Length) |
- |
0 |
|
- |
| Cl 7.3(Matched Belts) |
- |
0 |
|
- |
| Cl 4(Material And Workmanship) |
- |
0 |
|
- |
| Cl 5.1(Cross-Section Dimensions) |
- |
0 |
|
- |
| Cl 5.2(Cross-Section Dimensions) |
- |
0 |
|
- |
| Cl 6(DESIGNATION) |
- |
0 |
|
- |
| Cl 7(Length Measurement And Tolerances) |
- |
0 |
|
- |
| Cl 7.2.1(Determination of Pitch Length) |
- |
0 |
|
- |
| Cl 7.2.2(Determination of Pitch Length) |
- |
0 |
|
- |
| Cl 7.2.3(Determination of Pitch Length) |
- |
0 |
|
- |
| Cl 7.3(Matched Belts) |
- |
0 |
|
- |
|
26 Jul, 2027 |
- - |
| 7229 |
BIS, Central Laboratory (CL)
| None
| IS 617 (2024) |
Aluminium and Aluminium Alloys Ingots for Remelting and Castings for General Engineering Purposes â Specification (Fourth Revision) |
- |
- View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl-6.1, Table-1 (Fe) |
- |
|
|
|
| Cl-6.1, Table-1 (Cu) |
- |
|
|
|
| Cl-6.1, Table-1 (Mn) |
- |
|
|
|
| Cl-6.1, Table-1 (Mg) |
- |
|
|
|
| Cl-6.1, Table-1 (Cr) |
- |
|
|
|
| Cl-6.1, Table-1 (Ni) |
- |
|
|
|
| Cl-6.1, Table-1 (Zn) |
- |
|
|
|
| Cl-6.1, Table-1 (Pb) |
- |
|
|
|
| Cl-6.1, Table-1 (Sn) |
- |
|
|
|
| Cl-6.1, Table-1 (Ti) |
- |
|
|
|
| Cl-6.1, Table-1 (Others elements Each) |
- |
|
|
|
| Cl-6.1, Table-1 (Others elements Total) |
- |
|
|
|
| Cl-6.1, Table-1 (Aluminium) |
- |
|
|
|
| Cl-6.2 (The chemical analysis) |
- |
|
|
|
| Cl. 6 (Silicon) |
- |
|
|
|
| Cl. 6 (Silver) |
- |
|
|
|
| Cl. 6 (Zirconium) |
- |
|
|
|
| Cl. 6 (Titanium+Zirconium) |
- |
|
|
|
| Cl. 6 (Antimony) |
- |
|
|
|
| Cl. 6 (Cobalt) |
- |
|
|
|
| Cl. 6 (Antimony+Cobalt) |
- |
|
|
|
| Cl. 6 (Beryllium) |
- |
|
|
|
| Cl-7.2 (Tensile Tests) |
- |
|
|
|
| Cl-7.4 (Hardness) |
- |
|
|
|
| Cl-8 (Freedom from Defects) |
- |
|
|
|
|
- |
- - |
| 7230 |
CENTRAL INSTITUTE OF PETROCHEMICALS ENGINEERING & TECHNOLOGY (CIPET), RANCHI
| 5173614
| IS 16703 (2017) |
Textiles - High density polyethylene (HDPE) polypropylene (PP) woven sacks for packaging of 25 kg polymer materials - Specification |
25 KG POLYMER BAG |
20555 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4.2(Linear Density) |
- |
700 |
|
For Fabric tape: (Extra charges)
Material Identification: 1050/-
Melt Flow Index: 1100/-
Mesh Size:500/-
Tenacity: 1100/-
Density (Raw Material): 700/- |
| 4.2(Width of tape) |
- |
500 |
|
Clause No: 4.2
Thickness of tape: 500/-
Heat Shrinkage: 1700/-
Dimensional Stability: 700/- (Each condition)
GSM: 500
Clause No: 4.1 (Optional)
Raw Material Identification: 1050/- |
| 4.3(Sacks) |
- |
500 |
|
Visual |
| 4.3.1(Bottom Seam) |
- |
500 |
|
Outer Stitching: 500/-
Depth of seam over double fold: 500/-
No of Stitches per dm: 500/-
Identification of Stitching material: 1050/-
Breaking load of thread: 1100/- (500/- for sample preparation)
Presence of UV in Thread, 2000/- |
| 4.6(Capacity) |
- |
500 |
|
Extra charges as per Standard Clause no: 4.4 (For Lamination)
Identification of Lamination: 2000/-
GSM: 500/-
Lamination overhang: 500/-
For Clause no: 4.5
Identification of Liner: 2000/-
Dimensions of Liner: 500/-
Visual of Liner: 500/- |
| 5.2 Table 1(Dimensions) |
- |
500 |
|
Including Length, Width & Width of the gusset |
| 5.2 Table 1(Dimensions) |
- |
0 |
|
- |
| 5.2 Table 1(Ends per dm) |
- |
500 |
|
- |
| 5.2 Table 1(Picks per dm) |
- |
500 |
|
- |
| 5.2 Table 1(Mass of sack, Gusseted type, g - IS 1964) |
- |
500 |
|
- |
| 5.2 Table 1(Average breaking strength of fabric [Ravelled strip
method, 325 mm × 70mm1)] Min, N) (kgf): - IS 1969 (Part 1)) |
- |
2700 |
|
2200/- Including Warp + Weft Direction (Avg. Breaking Strength + Elongation at break) and 500/- for Specimen preparation |
| 5.2 Table 1(Average breaking strength of fabric [Ravelled strip
method, 325 mm × 70mm1)] Min, N2) (kgf): - IS 1969 (Part 1)) |
- |
0 |
|
- |
| 5.2 Table 1(Breaking strength of bottom seam (Ravelled strip
method), Min, N) (kgf) - IS 9030) |
- |
1100 |
|
- |
| 5.2 Table 1(Elongation at break of fabric (Ravelled strip method),
percent : IS 1969 (Part 1)) |
- |
0 |
|
- |
| 5.2 Table 1(Elongation at break of fabric (Ravelled strip method),
percent : IS 1969 (Part 1)) |
- |
0 |
|
- |
| 5.2 Table 1(Drop impact strength) |
- |
1600 |
|
500 for sample preparation/Conditioning |
| (Clauses 4.2, 5.1, 5.2, 5.3 and 5.4) Table 1 (Ash Content ,a) For UV stabilized sacks) |
- |
1200 |
|
Ash Content |
| (Clauses 4.2, 5.1, 5.2, 5.3 and 5.4) Table 1 (Ash Content ,b) For non- UV stabilized sacks) |
- |
0 |
|
- |
| 4.2,5.1,5.2,5.3,5.4(Breaking strenght after U.V. Exposure (Warp/Weft)) |
- |
2700 |
|
2200/- Including Warp + Weft Direction (Avg. Breaking Strength ) and 500/- for Specimen preparation |
| 4.2,5.1,5.2,5.3,5.4,(UV Resistance (192 hrs)(100 x 65+92x40)) |
- |
10180 |
|
- |
| 5.1(Mass of Bale) |
- |
0 |
|
- |
| 5.2 Table 1(Dimensions) |
- |
0 |
|
- |
| 5.2 Table 1(Dimensions) |
- |
0 |
|
- |
| 4.2(Linear Density) |
- |
0 |
|
- |
| 4.2(Width of tape) |
- |
0 |
|
- |
| 4.3(Sacks) |
- |
0 |
|
- |
| 4.3.1(Bottom Seam) |
- |
0 |
|
- |
| 4.6(Capacity) |
- |
0 |
|
- |
| 4.2,5.1,5.2,5.3,5.4(Breaking strenght after U.V. Exposure (Warp/Weft)) |
- |
0 |
|
- |
| 4.2,5.1,5.2,5.3,5.4,(UV Resistance (192 hrs)(100 x 65+92x40)) |
- |
0 |
|
- |
|
09 Aug, 2026 |