| 7231 |
BIS, Eastern Regional Laboratory (ERL)
| None
| IS 3626 (2001) |
Locked coil winding ropes - Specification (Second Revision) |
- |
- View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4.1-Table-1 (Diameter - IS 3626) |
- |
|
|
|
| 4.2 (Length - IS 3626) |
- |
|
|
|
| 4.1-Table-1 (Diameter - IS 3626) |
- |
|
|
|
| 5.3-Table-1 (Carbon - IS 1835) |
- |
|
|
|
| 5.3-Table-1 (Manganese - IS 1835) |
- |
|
|
|
| 5.3-Table-1 (Silicon - IS 1835) |
- |
|
|
|
| 5.3-Table-1 (Sulphur - IS 1835) |
- |
|
|
|
| 5.3-Table-1 (Phosphorur - IS 1835) |
- |
|
|
|
| 5.3-Table-1 (Copper - IS 1835) |
- |
|
|
|
| 5.3-Table-1 (Nickle - IS 1835) |
- |
|
|
|
| 5.3-Table-1 (Chromium - IS 1835) |
- |
|
|
|
|
- |
- Mech- Facility not available for Tensile and Torsion Test, Chem- Complete |
| 7232 |
Hi Physix Laboratory India Private Limited, Pune
| 7126926
| IS 17550 : Part 1 (2024) |
Household Refrigerating Appliances - Characteristics and Test Methods Part 1 General Requirements (First Revision) |
- |
265000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 5(MARKING) |
- |
2000 |
|
- |
| 8(MATERIALS, DESIGN, AND MANUFACTURE) |
- |
3000 |
|
Charges for Clause 13 Water Vapour condensation Test : Rs.50000. |
| 9(Testing The Air Tightness Of Door Or Lid Seal(S)) |
- |
5000 |
|
- |
| 10(Testing The Opening Force Of Door(S) Or Lid(S)) |
- |
10000 |
|
- |
| 11(Testing The Durability Of Hinges And Handles Of Door(S) And Lid(S) |
- |
50000 |
|
- |
| 12(Testing The Mechanical Strength Of Shelves And Similar Components) |
- |
10000 |
|
- |
| 14(Ice-Making Test (If Applicable)) |
- |
30000 |
|
- |
| 15(Test For Absence Of Odour And Taste) |
- |
50000 |
|
- |
| 16(Safety Requirements) |
- |
55000 |
|
For Production Routine tests as per clause 20.3 Rs.15000/- |
| 5(MARKING) |
- |
0 |
|
- |
| 8(MATERIALS, DESIGN, AND MANUFACTURE) |
- |
0 |
|
- |
| 9(Testing The Air Tightness Of Door Or Lid Seal(S)) |
- |
0 |
|
- |
| 10(Testing The Opening Force Of Door(S) Or Lid(S)) |
- |
0 |
|
- |
| 11(Testing The Durability Of Hinges And Handles Of Door(S) And Lid(S) |
- |
0 |
|
- |
| 12(Testing The Mechanical Strength Of Shelves And Similar Components) |
- |
0 |
|
- |
| 14(Ice-Making Test (If Applicable)) |
- |
0 |
|
- |
| 15(Test For Absence Of Odour And Taste) |
- |
0 |
|
- |
| 16(Safety Requirements) |
- |
0 |
|
- |
| 5(MARKING) |
- |
0 |
|
- |
| 8(MATERIALS, DESIGN, AND MANUFACTURE) |
- |
0 |
|
- |
| 9(Testing The Air Tightness Of Door Or Lid Seal(S)) |
- |
0 |
|
- |
| 10(Testing The Opening Force Of Door(S) Or Lid(S)) |
- |
0 |
|
- |
| 11(Testing The Durability Of Hinges And Handles Of Door(S) And Lid(S) |
- |
0 |
|
- |
| 12(Testing The Mechanical Strength Of Shelves And Similar Components) |
- |
0 |
|
- |
| 14(Ice-Making Test (If Applicable)) |
- |
0 |
|
- |
| 15(Test For Absence Of Odour And Taste) |
- |
0 |
|
- |
| 16(Safety Requirements) |
- |
0 |
|
- |
| 5(MARKING) |
- |
0 |
|
- |
| 8(MATERIALS, DESIGN, AND MANUFACTURE) |
- |
0 |
|
- |
| 9(Testing The Air Tightness Of Door Or Lid Seal(S)) |
- |
0 |
|
- |
| 10(Testing The Opening Force Of Door(S) Or Lid(S)) |
- |
0 |
|
- |
| 11(Testing The Durability Of Hinges And Handles Of Door(S) And Lid(S) |
- |
0 |
|
- |
| 12(Testing The Mechanical Strength Of Shelves And Similar Components) |
- |
0 |
|
- |
| 14(Ice-Making Test (If Applicable)) |
- |
0 |
|
- |
| 15(Test For Absence Of Odour And Taste) |
- |
0 |
|
- |
| 16(Safety Requirements) |
- |
0 |
|
- |
|
20 Jun, 2028 |
- Included w.e.f.03.03.2025 |
| 7233 |
Gravitas Laboratories Private Limited, Greater Noida
| 8182606
| IS 5522 (2014) |
Stainless steel sheets and strips for utensils - Specification (Third Revision) |
- |
6500 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl. 7.1 & 7.2 Table 1(Carbon -IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
250 |
|
- |
| Cl. 7.1 & 7.2 Table 1(Silicon -IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
250 |
|
- |
| Cl. 7.1 & 7.2 Table 1(Manganese -IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
250 |
|
- |
| Cl. 7.1 & 7.2 Table 1(Nickel -IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
250 |
|
- |
| Cl. 7.1 & 7.2 Table 1(Chromium -IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
250 |
|
- |
| Cl. 7.1 & 7.2 Table 1(Sulphur -IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
250 |
|
- |
| Cl. 7.1 & 7.2 Table 1(Phosphorus -IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
250 |
|
- |
| Cl. 7.1 & 7.2 Table 1(Nitrogen -IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
250 |
|
- |
| 8.2, Table 3(Tensile Test-1608:Part 1) |
- |
1200 |
|
- |
| 8.2, Table 3(Proof Stress, N/mm2) |
- |
1200 |
|
- |
| 8.2, Table 3(Tensile Strength, N/mm2) |
- |
1200 |
|
- |
| 8.2, Table 3(Elongation, %) |
- |
1200 |
|
- |
| 8.3(Hardness , max-IS 1500 or IS 1501 (Part 1) or IS 1586) |
- |
1200 |
|
- |
| 8.4(Bend Test) |
- |
1000 |
|
- |
| 8.5(Erichsen Cupping Test) |
- |
800 |
|
- |
| 10.1(Thickness, mm) |
- |
500 |
|
- |
| 10.2(width, mm) |
- |
500 |
|
- |
| 10.3(Length, mm) |
- |
500 |
|
- |
| 10.4(Flatness,mm) |
- |
500 |
|
- |
| 10.5(Camber, mm) |
- |
500 |
|
- |
| 11(Surface Finish) |
- |
500 |
|
- |
| Cl . 6 .0(Freedom from defect) |
- |
500 |
|
- |
|
- |
- Included w.e.f 13.05.2025 |
| 7234 |
BIS, Eastern Regional Laboratory (ERL)
| None
| IS 1363 : Part 3 (2018) |
Hexagon Head Bolts, Screws and Nuts of Product Grade ˜C ™ Part 3 (Style 1) Hexagon Nuts ( Size Range M 5 to M 64 ) ( Fifth Revision ) |
For all sizes |
- View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 3-Table 2 (Dimensions-D) |
- |
|
|
|
| 3-Table 1 (Dimensions-P) |
- |
|
|
|
| 4-Table 3 (General requirements) |
- |
|
|
|
| 4-Table 3 (Mechanical property-Rockwell hardness (ISO 898-1) HRB) |
- |
|
|
|
| 4-Table 3 (Mechanical property-Rockwell hardness (ISO 898-1) HRC) |
- |
|
|
|
| 4-Table 3 (Mechanical property-Surface integrity (ISO 898-1)-- Quench cracks (ISO 6157-3)) |
- |
|
|
|
| 4-Table 3 (Mechanical property-Surface integrity (ISO 898-1)-Forging cracks in socket head screws- (ISO 6157-3)) |
- |
|
|
|
| 4-Table 3 (Mechanical property-Surface integrity (ISO 898-1)-Damages - (ISO 6157-3)) |
- |
|
|
|
| 4-Table 3 (Mechanical property-Impact strength (ISO 898-1)) |
- |
|
|
|
| 4-Table 3 (Mechanical property-Percentage reduction of area after fracture for machined test pieces (ISO 898-1)) |
- |
|
|
|
|
- |
- Except thread properties and torque strength. |
| 7235 |
BIS, Eastern Regional Laboratory (ERL)
| None
| IS 8856 (1991) |
Hexagon weld nuts - Specification (First Revision) |
- |
Please see remarks View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 3 (Hardness) |
- |
|
|
|
| 3 (Material) |
- |
|
|
|
| 3 (Dimensions) |
- |
|
|
|
| 3 (Thread) |
- |
|
|
|
|
- |
- Except Proof load, Torque test |
| 7236 |
BIS, Eastern Regional Laboratory (ERL)
| None
| IS 18809 (2024) |
Wear and abrasion resistant steel sheet and plate � Specification |
For all grades except for the tests mentioned in remarks. |
Rs 14,250.00 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 8.1 (Table-5) (Hardness Test) |
- |
|
|
|
| 8.2 (Tensile test) |
- |
|
|
|
| 8.3 (Table 7) (Bend Test) |
- |
|
|
|
| 8.4 (Table 8) (Charpy V-Notch- Impact Test) |
- |
|
|
|
| 11 (Freedom From Defects) |
- |
|
|
|
| 12 (Dimenstions and Tolerences) |
- |
|
|
|
| Cl.7 (Carbon - IS 228 and its parts or any other intrumental/chemical methods) |
- |
|
|
|
| Cl.7 (Manganese - IS 228 and its parts or any other intrumental/chemical methods) |
- |
|
|
|
| Cl.7 (Silicon - IS 228 and its parts or any other intrumental/chemical methods) |
- |
|
|
|
| Cl.7 (Phosphorus - IS 228 and its parts or any other intrumental/chemical methods) |
- |
|
|
|
| Cl.7 (Sulphur - IS 228 and its parts or any other intrumental/chemical methods) |
- |
|
|
|
| Cl.7 (Chromium - IS 228 and its parts or any other intrumental/chemical methods) |
- |
|
|
|
| Cl.7 (Molybdenum - IS 228 and its parts or any other intrumental/chemical methods) |
- |
|
|
|
| Cl.7 (Nickel - IS 228 and its parts or any other intrumental/chemical methods) |
- |
|
|
|
| Cl.7 (Nitrogen - IS 228 and its parts or any other intrumental/chemical methods) |
- |
|
|
|
| 7.1 (Table 2) (Chemical Compostion ( B)) |
- |
|
|
|
| 7.1 (Table 3) (Chemical Compostion ( Nb)) |
- |
|
|
|
| 7.1 (Table 3) (Chemical Compostion ( Carbon Equivalent)) |
- |
|
|
|
| 7.1 (Table 3) (Chemical Compostion ( V)) |
- |
|
|
|
| 7.1 (Table 3) (Chemical Compostion ( Al)) |
- |
|
|
|
| 7.1 (Table 3) (Chemical Compostion (Ti)) |
- |
|
|
|
|
- |
- Hardness: Available for thickness above 15 mm.
Charpy impact: Available for -20 degree Celsius. |
| 7237 |
Gravitas Laboratories Private Limited, Greater Noida
| 8182606
| IS 12146 (1987) |
Specification for carbon manganese steel forgings for pressure vessels |
- |
9000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl. 5.1 & Table 1(Carbon- IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
300 |
|
- |
| Cl. 5.1 & Table 1(Silicon- IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
300 |
|
- |
| Cl. 5.1 & Table 1(Manganese- IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
300 |
|
- |
| Cl. 5.1 & Table 1(Sulphur- IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
300 |
|
- |
| Cl. 5.1 & Table 1(Phosphorus- IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
300 |
|
- |
| 7(Workmanship & Finish) |
- |
500 |
|
- |
| 8(Freedom from defects) |
- |
500 |
|
- |
| 6 and 9(Mechanical Properties and Test ) |
- |
4500 |
|
- |
| 6.1, Table 3 (Tensile Test-1608:Part 1) |
- |
1000 |
|
- |
| 6.1, Table 3 (Yield Strength, Mpa) |
- |
1000 |
|
- |
| 6.1, Table 3 (Tensile Strength, Mpa) |
- |
1000 |
|
- |
| 6.1, Table 3 (Elongation, %) |
- |
1000 |
|
- |
| 6.1, Table 3 (Reduction in area, Percent) |
- |
500 |
|
- |
| 6.1, Table 3 (Impact Test) |
- |
2500 |
|
- |
| Cl 5.1(Carbon- IS 228(Part 1)) |
- |
300 |
|
- |
| Cl 5.2(Sulphur- IS 228(Part 9)) |
- |
300 |
|
- |
| Cl 5.3(Phosphorous- IS 228(Part 3)) |
- |
300 |
|
- |
| Cl 5.4(Manganese- IS 228(Part 2)) |
- |
300 |
|
- |
| Cl 5.5(Silicon- IS 228(Part 2)) |
- |
300 |
|
- |
| Cl. 5.1 & Table 1(Carbon- IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
300 |
|
- |
| Cl. 5.1 & Table 1(Silicon- IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
300 |
|
- |
| Cl. 5.1 & Table 1(Manganese- IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
300 |
|
- |
| Cl. 5.1 & Table 1(Sulphur- IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
300 |
|
- |
| Cl. 5.1 & Table 1(Phosphorus- IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
300 |
|
- |
| 7(Workmanship & Finish) |
- |
300 |
|
- |
| 8(Freedom from defects) |
- |
300 |
|
- |
| 6 and 9(Mechanical Properties and Test ) |
- |
3000 |
|
- |
| 6.1, Table 3 (Tensile Test-1608:Part 1) |
- |
1500 |
|
- |
| 6.1, Table 3 (Yield Strength, Mpa) |
- |
1000 |
|
- |
| 6.1, Table 3 (Tensile Strength, Mpa) |
- |
1000 |
|
- |
| 6.1, Table 3 (Elongation, %) |
- |
800 |
|
- |
| 6.1, Table 3 (Reduction in area, Percent) |
- |
500 |
|
- |
| 6.1, Table 3 (Impact Test) |
- |
2500 |
|
- |
| Cl 5.1(Carbon- IS 228(Part 1)) |
- |
300 |
|
- |
| Cl 5.2(Sulphur- IS 228(Part 9)) |
- |
300 |
|
- |
| Cl 5.3(Phosphorous- IS 228(Part 3)) |
- |
300 |
|
- |
| Cl 5.4(Manganese- IS 228(Part 2)) |
- |
300 |
|
- |
| Cl 5.5(Silicon- IS 228(Part 2)) |
- |
300 |
|
- |
|
- |
- Included w.e.f 13.05.2025
Scope restricted to Grade I & II
Ultrasonic testing (optional) |
| 7238 |
Ace Test Labs & Metrology Pvt. Ltd., Sonipat
| 9162826
| IS 17541 (2021) |
Modular panel for security of premises specification |
- |
355000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Clause-5(Dimensions) |
- |
5000 |
|
- |
| Clause-6(Materials) |
- |
25000 |
|
- |
| Clause-8(Construction and General Requirements) |
- |
45000 |
|
- |
| Clause-9(Fittings) |
- |
35000 |
|
- |
| Clause-10(Finish) |
- |
15000 |
|
- |
| Clause-10.1(Cross Hatch Test) |
- |
35000 |
|
- |
| Clause-11.2, 1(Full length panel (Continuous design panel)) |
- |
150000 |
|
- |
| Clause-11.2, 2(Assemble panel/Segmented panel) |
- |
250000 |
|
- |
| Clause-12(Marking) |
- |
5000 |
|
- |
| Clause-5(Dimensions) |
- |
25000 |
|
- |
| Clause-6(Materials) |
- |
35000 |
|
- |
| Clause-8(Construction and General Requirements) |
- |
55000 |
|
- |
| Clause-9(Fittings) |
- |
55000 |
|
- |
| Clause-10(Finish) |
- |
25000 |
|
- |
| Clause-10.1(Cross Hatch Test) |
- |
55000 |
|
- |
| Clause-11.2, 1(Full length panel (Continuous design panel)) |
- |
150000 |
|
- |
| Clause-11.2, 2(Assemble panel/Segmented panel) |
- |
250000 |
|
- |
| Clause-12(Marking) |
- |
5000 |
|
- |
|
14 Nov, 2027 |
- Included w.e.f. 28.03.2025 |
| 7239 |
FARE Labs Pvt. Ltd., Gurugram
| 8135716
| IS 5982 (2003) |
Plantation white sugar - Specification (First Revision) |
-- |
7000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 5.1(Description) |
- |
500 |
|
- |
| 5.2, Table 1(Loss on drying) |
- |
500 |
|
- |
| 5.2, Table 1(Colour) |
- |
1000 |
|
- |
| 5.2, Table 1(Conductivity ash,) |
- |
500 |
|
- |
| 5.2, Table 1(Sulphur dioxide) |
- |
1000 |
|
- |
| 5.2, Table 1(Lead,) |
- |
1000 |
|
- |
| 5.2, Table 1(Polarization) |
- |
1000 |
|
- |
| 4.0(Grades) |
- |
500 |
|
- |
| 5.2, Table 1(Reducing sugars,) |
- |
1000 |
|
- |
|
09 Mar, 2029 |
- Included w.e.f.28.04.2025 |
| 7240 |
SWASTIK ELECTRONICS TESTING CENTRE (OPC) PVT. LTD., GHAZIABAD
| 8163826
| IS 16242 : Part 1 (2014) |
Uninterruptible power systems (UPS): Part 1 general and safety requirements for UPS |
-- |
40000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4.5(Components) |
- |
1000 |
|
- |
| 4.6(Power interface) |
- |
1000 |
|
- |
| 4.7(Marking & instructions) |
- |
1000 |
|
- |
| 5.1(Protection against shock and energy hazards) |
- |
1000 |
|
- |
| 5.2(Requirement of auxiliary circuits) |
- |
1000 |
|
- |
| 5.3(Protective earthing and bonding) |
- |
1000 |
|
- |
| 5.4(AC and DC power isolation) |
- |
1000 |
|
- |
| 5.5(Over current and earth fault condition) |
- |
1000 |
|
- |
| 5.6(Safety interlocks) |
- |
0 |
|
- |
| 5.7(CLEARANCES, CREEPAGE DISTANCES AND SOLID INSULATION) |
- |
1000 |
|
- |
| 6.1(Wiring, connections and supply) |
- |
1000 |
|
- |
| 6.2(Connection to power) |
- |
1000 |
|
- |
| 6.3(Wiring terminals for external power conductors) |
- |
1000 |
|
- |
| 7.1(Enclosure) |
- |
1000 |
|
- |
| 7.2(STABILITY) |
- |
1000 |
|
- |
| 7.3(MECHANICAL STRENGTH) |
- |
1000 |
|
- |
| 7.4(Construction details) |
- |
1000 |
|
- |
| 7.5(Resistance to fire) |
- |
1000 |
|
- |
| 7.6(Battery location) |
- |
1000 |
|
- |
| 7.7(Temperature rise) |
- |
2000 |
|
- |
| 8.1(General procision for earth leakage) |
- |
1000 |
|
- |
| 8.2(Electric Strength) |
- |
2000 |
|
- |
| 8.3(Abnormal operating and fault conditions) |
- |
2000 |
|
- |
| 9.0(Connection to telecommunication networks) |
- |
1000 |
|
- |
| 4.5/RD 1.5(Components) |
- |
1000 |
|
- |
| 2.10.5.11(SMPS/Main transformer) |
- |
1000 |
|
- |
| 2.10.6(PCB Material) |
- |
1000 |
|
- |
| 3.2.5(Non-rewirable plug with PVC sheathed cable) |
- |
1000 |
|
- |
| 3.2.4(Appliances inlets/connectors) |
- |
1000 |
|
- |
| 2.10.5.4(Semiconductor devices) |
- |
0 |
|
- |
| 2.10.5.13(Winding wires) |
- |
1000 |
|
- |
| 4.3.8(Batteries) |
- |
1000 |
|
- |
| 2.10.5.6(Thin sheet material) |
- |
1000 |
|
- |
| 5.6.1/ RD 2.8.7(Switches & Relays) |
- |
0 |
|
- |
| 6.1.1/ RD 3.1.4(Insulating Conductors) |
- |
1000 |
|
- |
| Annex I.5(Solid-state backfeed protection) |
- |
0 |
|
- |
| I.5(transient overvoltages) |
- |
0 |
|
- |
| I.5(voltage variations) |
- |
0 |
|
- |
| I.5(electromagnetic susceptibility) |
- |
0 |
|
- |
| I.5(electrostatic discharge) |
- |
0 |
|
- |
| Annex M(Ventilation of battery compartments) |
- |
0 |
|
- |
| 2.10.8 of RD(Tests on coated printed boards and coated components) |
- |
2000 |
|
- |
| 2.10.9 of RD(Thermal cycling) |
- |
2000 |
|
- |
| 2.10.10 of RD(Test for Pollution Degree 1 environment and for insulating compound) |
- |
2000 |
|
- |
| 2.10.11 of RD(Tests for semiconductor devices and for cemented joints) |
- |
0 |
|
- |
| Annex L.5, Cl.3.3.3(Non-linear loads) |
- |
0 |
|
- |
| 4.5(Components) |
- |
0 |
|
- |
| 4.6(Power interface) |
- |
0 |
|
- |
| 4.7(Marking & instructions) |
- |
0 |
|
- |
| 5.1(Protection against shock and energy hazards) |
- |
0 |
|
- |
| 5.2(Requirement of auxiliary circuits) |
- |
0 |
|
- |
| 5.3(Protective earthing and bonding) |
- |
0 |
|
- |
| 5.4(AC and DC power isolation) |
- |
0 |
|
- |
| 5.5(Over current and earth fault condition) |
- |
0 |
|
- |
| 5.6(Safety interlocks) |
- |
0 |
|
- |
| 5.7(CLEARANCES, CREEPAGE DISTANCES AND SOLID INSULATION) |
- |
0 |
|
- |
| 6.1(Wiring, connections and supply) |
- |
0 |
|
- |
| 6.2(Connection to power) |
- |
0 |
|
- |
| 6.3(Wiring terminals for external power conductors) |
- |
0 |
|
- |
| 7.1(Enclosure) |
- |
0 |
|
- |
| 7.2(STABILITY) |
- |
0 |
|
- |
| 7.3(MECHANICAL STRENGTH) |
- |
0 |
|
- |
| 7.4(Construction details) |
- |
0 |
|
- |
| 7.5(Resistance to fire) |
- |
0 |
|
- |
| 7.6(Battery location) |
- |
0 |
|
- |
| 7.7(Temperature rise) |
- |
0 |
|
- |
| 8.1(General procision for earth leakage) |
- |
0 |
|
- |
| 8.2(Electric Strength) |
- |
0 |
|
- |
| 8.3(Abnormal operating and fault conditions) |
- |
0 |
|
- |
| 9.0(Connection to telecommunication networks) |
- |
0 |
|
- |
| 4.5/RD 1.5(Components) |
- |
0 |
|
- |
| 2.10.5.11(SMPS/Main transformer) |
- |
0 |
|
- |
| 2.10.6(PCB Material) |
- |
0 |
|
- |
| 3.2.5(Non-rewirable plug with PVC sheathed cable) |
- |
0 |
|
- |
| 3.2.4(Appliances inlets/connectors) |
- |
0 |
|
- |
| 2.10.5.4(Semiconductor devices) |
- |
0 |
|
- |
| 2.10.5.13(Winding wires) |
- |
0 |
|
- |
| 4.3.8(Batteries) |
- |
0 |
|
- |
| 2.10.5.6(Thin sheet material) |
- |
0 |
|
- |
| 5.6.1/ RD 2.8.7(Switches & Relays) |
- |
0 |
|
- |
| 6.1.1/ RD 3.1.4(Insulating Conductors) |
- |
0 |
|
- |
| Annex I.5(Solid-state backfeed protection) |
- |
0 |
|
- |
| I.5(transient overvoltages) |
- |
0 |
|
- |
| I.5(voltage variations) |
- |
0 |
|
- |
| I.5(electromagnetic susceptibility) |
- |
0 |
|
- |
| I.5(electrostatic discharge) |
- |
0 |
|
- |
| Annex M(Ventilation of battery compartments) |
- |
0 |
|
- |
| 2.10.8 of RD(Tests on coated printed boards and coated components) |
- |
0 |
|
- |
| 2.10.9 of RD(Thermal cycling) |
- |
0 |
|
- |
| 2.10.10 of RD(Test for Pollution Degree 1 environment and for insulating compound) |
- |
0 |
|
- |
| 2.10.11 of RD(Tests for semiconductor devices and for cemented joints) |
- |
0 |
|
- |
| Annex L.5, Cl.3.3.3(Non-linear loads) |
- |
0 |
|
- |
| 4.5(Components) |
- |
0 |
|
- |
| 4.6(Power interface) |
- |
0 |
|
- |
| 4.7(Marking & instructions) |
- |
0 |
|
- |
| 5.1(Protection against shock and energy hazards) |
- |
0 |
|
- |
| 5.2(Requirement of auxiliary circuits) |
- |
0 |
|
- |
| 5.3(Protective earthing and bonding) |
- |
0 |
|
- |
| 5.4(AC and DC power isolation) |
- |
0 |
|
- |
| 5.5(Over current and earth fault condition) |
- |
0 |
|
- |
| 5.6(Safety interlocks) |
- |
0 |
|
- |
| 5.7(CLEARANCES, CREEPAGE DISTANCES AND SOLID INSULATION) |
- |
0 |
|
- |
| 6.1(Wiring, connections and supply) |
- |
0 |
|
- |
| 6.2(Connection to power) |
- |
0 |
|
- |
| 6.3(Wiring terminals for external power conductors) |
- |
0 |
|
- |
| 7.1(Enclosure) |
- |
0 |
|
- |
| 7.2(STABILITY) |
- |
0 |
|
- |
| 7.3(MECHANICAL STRENGTH) |
- |
0 |
|
- |
| 7.4(Construction details) |
- |
0 |
|
- |
| 7.5(Resistance to fire) |
- |
0 |
|
- |
| 7.6(Battery location) |
- |
0 |
|
- |
| 7.7(Temperature rise) |
- |
0 |
|
- |
| 8.1(General procision for earth leakage) |
- |
0 |
|
- |
| 8.2(Electric Strength) |
- |
0 |
|
- |
| 8.3(Abnormal operating and fault conditions) |
- |
0 |
|
- |
| 9.0(Connection to telecommunication networks) |
- |
0 |
|
- |
| 4.5/RD 1.5(Components) |
- |
0 |
|
- |
| 2.10.5.11(SMPS/Main transformer) |
- |
0 |
|
- |
| 2.10.6(PCB Material) |
- |
0 |
|
- |
| 3.2.5(Non-rewirable plug with PVC sheathed cable) |
- |
0 |
|
- |
| 3.2.4(Appliances inlets/connectors) |
- |
0 |
|
- |
| 2.10.5.4(Semiconductor devices) |
- |
0 |
|
- |
| 2.10.5.13(Winding wires) |
- |
0 |
|
- |
| 4.3.8(Batteries) |
- |
0 |
|
- |
| 2.10.5.6(Thin sheet material) |
- |
0 |
|
- |
| 5.6.1/ RD 2.8.7(Switches & Relays) |
- |
0 |
|
- |
| 6.1.1/ RD 3.1.4(Insulating Conductors) |
- |
0 |
|
- |
| Annex I.5(Solid-state backfeed protection) |
- |
0 |
|
- |
| I.5(transient overvoltages) |
- |
0 |
|
- |
| I.5(voltage variations) |
- |
0 |
|
- |
| I.5(electromagnetic susceptibility) |
- |
0 |
|
- |
| I.5(electrostatic discharge) |
- |
0 |
|
- |
| Annex M(Ventilation of battery compartments) |
- |
0 |
|
- |
| 2.10.8 of RD(Tests on coated printed boards and coated components) |
- |
0 |
|
- |
| 2.10.9 of RD(Thermal cycling) |
- |
0 |
|
- |
| 2.10.10 of RD(Test for Pollution Degree 1 environment and for insulating compound) |
- |
0 |
|
- |
| 2.10.11 of RD(Tests for semiconductor devices and for cemented joints) |
- |
0 |
|
- |
| Annex L.5, Cl.3.3.3(Non-linear loads) |
- |
0 |
|
- |
|
15 May, 2028 |
- Included w.e.f.28.04.2025
Exclusion
2.10.5.4 (Semiconductor devices), 5.6.1/ RD 2.8.7 (Switches & Relays), Annex I.5 (Solid-state backfeed protection), I.5 (transient overvoltages), I.5 (voltage variations), I.5 (electromagnetic susceptibility), I.5 (electrostatic discharge), Annex M (Ventilation of battery compartments), 2.10.11 of RD (Tests for semiconductor devices and for cemented joints), Annex L.5, Cl.3.3.3 (Non-linear loads), 4.3.8 (Batteries), 4.5/RD 1.5 (Components) |
| 7241 |
Conformity Testing Labs Pvt. Ltd. Unit 2 (A33)
| 8139626
| IS 18480 : Part 1 (2023) |
Cross Recessed Tapping Screws: Part 1 Pan Head |
- |
20500 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Clause. 3.0(Dimenssions.) |
- |
3000 |
|
- |
| Clause. 3.0(Thread size.) |
- |
3000 |
|
- |
| Clause. 3.0(Length) |
- |
3000 |
|
- |
| Clause. 4.0(Material) |
- |
3000 |
|
- |
| Clause. 4.0(Thread) |
- |
3000 |
|
- |
| Clause. 4.0(Cross Recess) |
- |
3000 |
|
- |
| Clause. 4.0(Tolerances) |
- |
3000 |
|
- |
| Clause. 4.0(Mechnical and functional properties.) |
- |
3000 |
|
- |
| Clause. 4.0(Finish) |
- |
3000 |
|
- |
| Clause. 4.0(Acceptability) |
- |
3000 |
|
- |
| Clause.5.0(Designation) |
- |
3000 |
|
- |
| Clause.5.0(Marking) |
- |
3000 |
|
- |
|
05 Apr, 2027 |
- Included w.e.f. 03.03.2025 |
| 7242 |
PLANET ANALYSIS PRIVATE LIMITED, KANPUR
| 9125906
| IS 2573 (2023) |
LEATHER GAUNTLETS AND MITTENS SPECIFICATION |
- |
9000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Table 1 Cl. 5.2.1, Sl No (i)(Solvent exractable substances, percent by mass) |
- |
800 |
|
5 % DISCOUNT TO BIS SAMPLES ONLY
TESTING CHARGES Rs. 9000.00 |
| Table 1 Cl. 5.2.1, Sl No (ii)(Chromium content (as Cr2O3), percent by mass) |
- |
800 |
|
- |
| Table 1 Cl. 5.2.1, Sl No (iii)(pH of aqueous extract) |
- |
1300 |
|
(III) pH 300
(IV) DOUBLE HOLE STITCH TEAR STRENGTH 500
(V) SHRINKAGE TEMPERATURE 500 |
| 4.1(Type) |
- |
200 |
|
- |
| 4.2(Length(L)) |
- |
150 |
|
- |
| 5.1(Dimensions(fig 1 to fig 3)) |
- |
1000 |
|
Any one size dimension Rs. 1000.00 |
| 5.2.1(a)(Thickness of Leather and Flesh split) |
- |
300 |
|
- |
| 5.2.1(Table 1, serial vi)(Abrasion resistance, Dry condition) |
- |
600 |
|
- |
| 5.2.1(Table 1, serial vi)(Abrasion resistance, Wet condition) |
- |
600 |
|
- |
| 5.2.2(Table 2)(Thread Length, Min) |
- |
400 |
|
- |
| 5.2.2(Table2)(Single thread breaking load, Min) |
- |
500 |
|
- |
| 5.3.1.2(Construction(for Type 1)) |
- |
1000 |
|
- |
| 5.3.1.3(Construction(for Type 1)) |
- |
0 |
|
- |
| 5.3.1.4(Construction(for Type 1)) |
- |
0 |
|
- |
| 5.3.1.5(Construction(for Type 1)) |
- |
0 |
|
- |
| 5.3.1.6(Construction(for Type 1)) |
- |
0 |
|
- |
| 5.3.1.7(Construction(for Type 1)) |
- |
0 |
|
- |
| 5.3.1.8(Construction(for Type 1)) |
- |
0 |
|
- |
| 5.3.1.9(Construction(for Type 1)) |
- |
0 |
|
- |
| 5.3.1.10(Construction(for Type 1)) |
- |
0 |
|
- |
| 5.3.1.11(Workmanship and finish) |
- |
0 |
|
- |
| 5.3.2.2(Construction(for Type 2)) |
- |
2750 |
|
CONSTRUCTION 1000.00
TABLE 3 COTTON CANVAS 1750.00 |
| 5.3.2.3(Construction(for Type 2)) |
- |
0 |
|
- |
| 5.3.2.4(Construction(for Type 2)) |
- |
0 |
|
- |
| 5.3.2.5(Construction(for Type 2)) |
- |
0 |
|
- |
| 5.3.2.6(Construction(for Type 2)) |
- |
0 |
|
- |
| 5.3.2.7(Construction(for Type 2)) |
- |
0 |
|
- |
| 5.3.2.8(Construction(for Type 2)) |
- |
0 |
|
- |
| 5.3.2.9(Construction(for Type 2)) |
- |
0 |
|
- |
| 5.3.2.10(Construction(for Type 2)) |
- |
0 |
|
- |
| 5.3.2.11(Construction(for Type 2)) |
- |
0 |
|
- |
| 5.3.2.12(Workmanship and finish) |
- |
0 |
|
- |
| 5.3.3.2(Construction(for Type 3)) |
- |
1000 |
|
- |
| 5.3.3.3(Construction(for Type 3)) |
- |
0 |
|
- |
| 5.3.3.4(Construction(for Type 3)) |
- |
0 |
|
- |
| 5.3.3.5(Construction(for Type 3)) |
- |
0 |
|
- |
| 5.3.3.6(Construction(for Type 3)) |
- |
0 |
|
- |
| 5.3.3.7(Construction(for Type 3)) |
- |
0 |
|
- |
| 5.3.3.8(Construction(for Type 3)) |
- |
0 |
|
- |
| 5.3.3.9(Construction(for Type 3)) |
- |
0 |
|
- |
| 5.3.3.10(Construction(for Type 3)) |
- |
0 |
|
- |
| 5.3.3.11(Construction(for Type 3)) |
- |
0 |
|
- |
| 5.3.3.12(Construction(for Type 3)) |
- |
0 |
|
- |
| 5.3.3.13(Construction(for Type 3)) |
- |
0 |
|
- |
| 5.3.3.14(Construction(for Type 3)) |
- |
0 |
|
- |
| 5.3.3.15(Workmanship and finish) |
- |
500 |
|
CLAUSE 6 HEAT RESISTANCE TEST 500.00 |
|
20 Jan, 2028 |
- Included w.e.f.04.03.2025 |
| 7243 |
Gravitas Laboratories Private Limited, Greater Noida
| 8182606
| IS 17404 (2020) |
Electrogalvanized Hot Rolled and Cold Reduced Carbon Steel Sheets and Strips ” Specification |
all grades |
12000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 7.1 (As per IS 1079, IS 5986, IS 513(pt-1 & 2))(C -IS 228) |
- |
7000 |
|
- |
| 7.1 (As per IS 1079, IS 5986, IS 513(pt-1 & 2))(Mn - IS 228) |
- |
7000 |
|
- |
| 7.1 (As per IS 1079, IS 5986, IS 513(pt-1 & 2))(P - IS 228 ) |
- |
7000 |
|
- |
| 7.1 (As per IS 1079, IS 5986, IS 513(pt-1 & 2))(S - IS 228) |
- |
7000 |
|
- |
| 7.1 (As per IS 1079, IS 5986, IS 513(pt-1 & 2))(N - IS 228) |
- |
7000 |
|
- |
| 7.1 (As per IS 1079, IS 5986, IS 513(pt-1 & 2))(Al - IS 228) |
- |
7000 |
|
- |
| 7.1 (As per IS 1079, IS 5986, IS 513(pt-1 & 2))(Si - IS 228) |
- |
7000 |
|
- |
| 7.1 (As per IS 1079, IS 5986, IS 513(pt-1 & 2))(Cu - IS 228) |
- |
7000 |
|
- |
| 7.1 (As per IS 1079, IS 5986, IS 513(pt-1 & 2))(Micro alloy element- IS 228) |
- |
7000 |
|
- |
| 7.1 (As per IS 1079, IS 5986, IS 513(pt-1 & 2))(Boron in micro alloy element- IS 228) |
- |
7000 |
|
- |
| 7.1 (As per IS 5986)(CE- IS 228) |
- |
7000 |
|
- |
| 8.3.1 (As per IS 1079, IS 5986, IS 513(pt-1 & 2))(Yield strength - IS 1608(Pt-1)) |
- |
5000 |
|
- |
| 8.3.1 (As per IS 1079, IS 5986, IS 513(pt-1 & 2))(Tensile Strength - IS 1608(Pt-1)) |
- |
5000 |
|
- |
| 8.3.1 (As per IS 1079, IS 5986, IS 513(pt-1 & 2))(Elongation - IS 1608(Pt-1)) |
- |
5000 |
|
- |
| 9.1, 9.1.1-Table 1(Coating Mass per Surface, Min - IS 12860 & IS 6745) |
- |
5000 |
|
- |
| 9.1, 9.1.1-Table 1(Coating Mass per Surface, Max - IS 12860 & IS 6746) |
- |
5000 |
|
- |
| 9.2.2-Table 2(Coating Adhesion Test- IS 17404) |
- |
5000 |
|
- |
| 10.1(Coil Internal Diameter-IS17404) |
- |
5000 |
|
- |
| 10.2 (As per IS 1079, IS 5986, IS 513(pt-1 & 2))(Width) |
- |
5000 |
|
- |
| 10.2 (As per IS 1079, IS 5986, IS 513(pt-1 & 2))(Length) |
- |
5000 |
|
- |
| 10.2 (As per IS 1079, IS 5986, IS 513(pt-1 & 2))(Thickness) |
- |
5000 |
|
- |
| 7.1 (As per IS 1079, IS 5986, IS 513(pt-1 & 2))(C -IS 228) |
- |
0 |
|
- |
| 7.1 (As per IS 1079, IS 5986, IS 513(pt-1 & 2))(Mn - IS 228) |
- |
0 |
|
- |
| 7.1 (As per IS 1079, IS 5986, IS 513(pt-1 & 2))(P - IS 228 ) |
- |
0 |
|
- |
| 7.1 (As per IS 1079, IS 5986, IS 513(pt-1 & 2))(S - IS 228) |
- |
0 |
|
- |
| 7.1 (As per IS 1079, IS 5986, IS 513(pt-1 & 2))(N - IS 228) |
- |
0 |
|
- |
| 7.1 (As per IS 1079, IS 5986, IS 513(pt-1 & 2))(Al - IS 228) |
- |
0 |
|
- |
| 7.1 (As per IS 1079, IS 5986, IS 513(pt-1 & 2))(Si - IS 228) |
- |
0 |
|
- |
| 7.1 (As per IS 1079, IS 5986, IS 513(pt-1 & 2))(Cu - IS 228) |
- |
0 |
|
- |
| 7.1 (As per IS 1079, IS 5986, IS 513(pt-1 & 2))(Micro alloy element- IS 228) |
- |
0 |
|
- |
| 7.1 (As per IS 1079, IS 5986, IS 513(pt-1 & 2))(Boron in micro alloy element- IS 228) |
- |
0 |
|
- |
| 7.1 (As per IS 5986)(CE- IS 228) |
- |
0 |
|
- |
| 8.3.1 (As per IS 1079, IS 5986, IS 513(pt-1 & 2))(Yield strength - IS 1608(Pt-1)) |
- |
0 |
|
- |
| 8.3.1 (As per IS 1079, IS 5986, IS 513(pt-1 & 2))(Tensile Strength - IS 1608(Pt-1)) |
- |
0 |
|
- |
| 8.3.1 (As per IS 1079, IS 5986, IS 513(pt-1 & 2))(Elongation - IS 1608(Pt-1)) |
- |
0 |
|
- |
| 9.1, 9.1.1-Table 1(Coating Mass per Surface, Min - IS 12860 & IS 6745) |
- |
0 |
|
- |
| 9.1, 9.1.1-Table 1(Coating Mass per Surface, Max - IS 12860 & IS 6746) |
- |
0 |
|
- |
| 9.2.2-Table 2(Coating Adhesion Test- IS 17404) |
- |
0 |
|
- |
| 10.1(Coil Internal Diameter-IS17404) |
- |
0 |
|
- |
| 10.2 (As per IS 1079, IS 5986, IS 513(pt-1 & 2))(Width) |
- |
0 |
|
- |
| 10.2 (As per IS 1079, IS 5986, IS 513(pt-1 & 2))(Length) |
- |
0 |
|
- |
| 10.2 (As per IS 1079, IS 5986, IS 513(pt-1 & 2))(Thickness) |
- |
0 |
|
- |
| 7.1 (As per IS 1079, IS 5986, IS 513(pt-1 & 2))(C -IS 228) |
- |
0 |
|
- |
| 7.1 (As per IS 1079, IS 5986, IS 513(pt-1 & 2))(Mn - IS 228) |
- |
0 |
|
- |
| 7.1 (As per IS 1079, IS 5986, IS 513(pt-1 & 2))(P - IS 228 ) |
- |
0 |
|
- |
| 7.1 (As per IS 1079, IS 5986, IS 513(pt-1 & 2))(S - IS 228) |
- |
0 |
|
- |
| 7.1 (As per IS 1079, IS 5986, IS 513(pt-1 & 2))(N - IS 228) |
- |
0 |
|
- |
| 7.1 (As per IS 1079, IS 5986, IS 513(pt-1 & 2))(Al - IS 228) |
- |
0 |
|
- |
| 7.1 (As per IS 1079, IS 5986, IS 513(pt-1 & 2))(Si - IS 228) |
- |
0 |
|
- |
| 7.1 (As per IS 1079, IS 5986, IS 513(pt-1 & 2))(Cu - IS 228) |
- |
0 |
|
- |
| 7.1 (As per IS 1079, IS 5986, IS 513(pt-1 & 2))(Micro alloy element- IS 228) |
- |
0 |
|
- |
| 7.1 (As per IS 1079, IS 5986, IS 513(pt-1 & 2))(Boron in micro alloy element- IS 228) |
- |
0 |
|
- |
| 7.1 (As per IS 5986)(CE- IS 228) |
- |
0 |
|
- |
| 8.3.1 (As per IS 1079, IS 5986, IS 513(pt-1 & 2))(Yield strength - IS 1608(Pt-1)) |
- |
0 |
|
- |
| 8.3.1 (As per IS 1079, IS 5986, IS 513(pt-1 & 2))(Tensile Strength - IS 1608(Pt-1)) |
- |
0 |
|
- |
| 8.3.1 (As per IS 1079, IS 5986, IS 513(pt-1 & 2))(Elongation - IS 1608(Pt-1)) |
- |
0 |
|
- |
| 9.1, 9.1.1-Table 1(Coating Mass per Surface, Min - IS 12860 & IS 6745) |
- |
0 |
|
- |
| 9.1, 9.1.1-Table 1(Coating Mass per Surface, Max - IS 12860 & IS 6746) |
- |
0 |
|
- |
| 9.2.2-Table 2(Coating Adhesion Test- IS 17404) |
- |
0 |
|
- |
| 10.1(Coil Internal Diameter-IS17404) |
- |
0 |
|
- |
| 10.2 (As per IS 1079, IS 5986, IS 513(pt-1 & 2))(Width) |
- |
0 |
|
- |
| 10.2 (As per IS 1079, IS 5986, IS 513(pt-1 & 2))(Length) |
- |
0 |
|
- |
| 10.2 (As per IS 1079, IS 5986, IS 513(pt-1 & 2))(Thickness) |
- |
0 |
|
- |
| 7.1 (As per IS 1079, IS 5986, IS 513(pt-1 & 2))(C -IS 228) |
- |
0 |
|
- |
| 7.1 (As per IS 1079, IS 5986, IS 513(pt-1 & 2))(Mn - IS 228) |
- |
0 |
|
- |
| 7.1 (As per IS 1079, IS 5986, IS 513(pt-1 & 2))(P - IS 228 ) |
- |
0 |
|
- |
| 7.1 (As per IS 1079, IS 5986, IS 513(pt-1 & 2))(S - IS 228) |
- |
0 |
|
- |
| 7.1 (As per IS 1079, IS 5986, IS 513(pt-1 & 2))(N - IS 228) |
- |
0 |
|
- |
| 7.1 (As per IS 1079, IS 5986, IS 513(pt-1 & 2))(Al - IS 228) |
- |
0 |
|
- |
| 7.1 (As per IS 1079, IS 5986, IS 513(pt-1 & 2))(Si - IS 228) |
- |
0 |
|
- |
| 7.1 (As per IS 1079, IS 5986, IS 513(pt-1 & 2))(Cu - IS 228) |
- |
0 |
|
- |
| 7.1 (As per IS 1079, IS 5986, IS 513(pt-1 & 2))(Micro alloy element- IS 228) |
- |
0 |
|
- |
| 7.1 (As per IS 1079, IS 5986, IS 513(pt-1 & 2))(Boron in micro alloy element- IS 228) |
- |
0 |
|
- |
| 7.1 (As per IS 5986)(CE- IS 228) |
- |
0 |
|
- |
| 8.3.1 (As per IS 1079, IS 5986, IS 513(pt-1 & 2))(Yield strength - IS 1608(Pt-1)) |
- |
0 |
|
- |
| 8.3.1 (As per IS 1079, IS 5986, IS 513(pt-1 & 2))(Tensile Strength - IS 1608(Pt-1)) |
- |
0 |
|
- |
| 8.3.1 (As per IS 1079, IS 5986, IS 513(pt-1 & 2))(Elongation - IS 1608(Pt-1)) |
- |
0 |
|
- |
| 9.1, 9.1.1-Table 1(Coating Mass per Surface, Min - IS 12860 & IS 6745) |
- |
0 |
|
- |
| 9.1, 9.1.1-Table 1(Coating Mass per Surface, Max - IS 12860 & IS 6746) |
- |
0 |
|
- |
| 9.2.2-Table 2(Coating Adhesion Test- IS 17404) |
- |
0 |
|
- |
| 10.1(Coil Internal Diameter-IS17404) |
- |
0 |
|
- |
| 10.2 (As per IS 1079, IS 5986, IS 513(pt-1 & 2))(Width) |
- |
0 |
|
- |
| 10.2 (As per IS 1079, IS 5986, IS 513(pt-1 & 2))(Length) |
- |
0 |
|
- |
| 10.2 (As per IS 1079, IS 5986, IS 513(pt-1 & 2))(Thickness) |
- |
0 |
|
- |
| 7.1 (As per IS 1079, IS 5986, IS 513(pt-1 & 2))(C -IS 228) |
- |
0 |
|
- |
| 7.1 (As per IS 1079, IS 5986, IS 513(pt-1 & 2))(Mn - IS 228) |
- |
0 |
|
- |
| 7.1 (As per IS 1079, IS 5986, IS 513(pt-1 & 2))(P - IS 228 ) |
- |
0 |
|
- |
| 7.1 (As per IS 1079, IS 5986, IS 513(pt-1 & 2))(S - IS 228) |
- |
0 |
|
- |
| 7.1 (As per IS 1079, IS 5986, IS 513(pt-1 & 2))(N - IS 228) |
- |
0 |
|
- |
| 7.1 (As per IS 1079, IS 5986, IS 513(pt-1 & 2))(Al - IS 228) |
- |
0 |
|
- |
| 7.1 (As per IS 1079, IS 5986, IS 513(pt-1 & 2))(Si - IS 228) |
- |
0 |
|
- |
| 7.1 (As per IS 1079, IS 5986, IS 513(pt-1 & 2))(Cu - IS 228) |
- |
0 |
|
- |
| 7.1 (As per IS 1079, IS 5986, IS 513(pt-1 & 2))(Micro alloy element- IS 228) |
- |
0 |
|
- |
| 7.1 (As per IS 1079, IS 5986, IS 513(pt-1 & 2))(Boron in micro alloy element- IS 228) |
- |
0 |
|
- |
| 7.1 (As per IS 5986)(CE- IS 228) |
- |
0 |
|
- |
| 8.3.1 (As per IS 1079, IS 5986, IS 513(pt-1 & 2))(Yield strength - IS 1608(Pt-1)) |
- |
0 |
|
- |
| 8.3.1 (As per IS 1079, IS 5986, IS 513(pt-1 & 2))(Tensile Strength - IS 1608(Pt-1)) |
- |
0 |
|
- |
| 8.3.1 (As per IS 1079, IS 5986, IS 513(pt-1 & 2))(Elongation - IS 1608(Pt-1)) |
- |
0 |
|
- |
| 9.1, 9.1.1-Table 1(Coating Mass per Surface, Min - IS 12860 & IS 6745) |
- |
0 |
|
- |
| 9.1, 9.1.1-Table 1(Coating Mass per Surface, Max - IS 12860 & IS 6746) |
- |
0 |
|
- |
| 9.2.2-Table 2(Coating Adhesion Test- IS 17404) |
- |
0 |
|
- |
| 10.1(Coil Internal Diameter-IS17404) |
- |
0 |
|
- |
| 10.2 (As per IS 1079, IS 5986, IS 513(pt-1 & 2))(Width) |
- |
0 |
|
- |
| 10.2 (As per IS 1079, IS 5986, IS 513(pt-1 & 2))(Length) |
- |
0 |
|
- |
| 10.2 (As per IS 1079, IS 5986, IS 513(pt-1 & 2))(Thickness) |
- |
0 |
|
- |
| 7.1 (As per IS 1079, IS 5986, IS 513(pt-1 & 2))(C -IS 228) |
- |
0 |
|
- |
| 7.1 (As per IS 1079, IS 5986, IS 513(pt-1 & 2))(Mn - IS 228) |
- |
0 |
|
- |
| 7.1 (As per IS 1079, IS 5986, IS 513(pt-1 & 2))(P - IS 228 ) |
- |
0 |
|
- |
| 7.1 (As per IS 1079, IS 5986, IS 513(pt-1 & 2))(S - IS 228) |
- |
0 |
|
- |
| 7.1 (As per IS 1079, IS 5986, IS 513(pt-1 & 2))(N - IS 228) |
- |
0 |
|
- |
| 7.1 (As per IS 1079, IS 5986, IS 513(pt-1 & 2))(Al - IS 228) |
- |
0 |
|
- |
| 7.1 (As per IS 1079, IS 5986, IS 513(pt-1 & 2))(Si - IS 228) |
- |
0 |
|
- |
| 7.1 (As per IS 1079, IS 5986, IS 513(pt-1 & 2))(Cu - IS 228) |
- |
0 |
|
- |
| 7.1 (As per IS 1079, IS 5986, IS 513(pt-1 & 2))(Micro alloy element- IS 228) |
- |
0 |
|
- |
| 7.1 (As per IS 1079, IS 5986, IS 513(pt-1 & 2))(Boron in micro alloy element- IS 228) |
- |
0 |
|
- |
| 7.1 (As per IS 5986)(CE- IS 228) |
- |
0 |
|
- |
| 8.3.1 (As per IS 1079, IS 5986, IS 513(pt-1 & 2))(Yield strength - IS 1608(Pt-1)) |
- |
0 |
|
- |
| 8.3.1 (As per IS 1079, IS 5986, IS 513(pt-1 & 2))(Tensile Strength - IS 1608(Pt-1)) |
- |
0 |
|
- |
| 8.3.1 (As per IS 1079, IS 5986, IS 513(pt-1 & 2))(Elongation - IS 1608(Pt-1)) |
- |
0 |
|
- |
| 9.1, 9.1.1-Table 1(Coating Mass per Surface, Min - IS 12860 & IS 6745) |
- |
0 |
|
- |
| 9.1, 9.1.1-Table 1(Coating Mass per Surface, Max - IS 12860 & IS 6746) |
- |
0 |
|
- |
| 9.2.2-Table 2(Coating Adhesion Test- IS 17404) |
- |
0 |
|
- |
| 10.1(Coil Internal Diameter-IS17404) |
- |
0 |
|
- |
| 10.2 (As per IS 1079, IS 5986, IS 513(pt-1 & 2))(Width) |
- |
0 |
|
- |
| 10.2 (As per IS 1079, IS 5986, IS 513(pt-1 & 2))(Length) |
- |
0 |
|
- |
| 10.2 (As per IS 1079, IS 5986, IS 513(pt-1 & 2))(Thickness) |
- |
0 |
|
- |
| 7.1 (As per IS 1079, IS 5986, IS 513(pt-1 & 2))(C -IS 228) |
- |
0 |
|
- |
| 7.1 (As per IS 1079, IS 5986, IS 513(pt-1 & 2))(Mn - IS 228) |
- |
0 |
|
- |
| 7.1 (As per IS 1079, IS 5986, IS 513(pt-1 & 2))(P - IS 228 ) |
- |
0 |
|
- |
| 7.1 (As per IS 1079, IS 5986, IS 513(pt-1 & 2))(S - IS 228) |
- |
0 |
|
- |
| 7.1 (As per IS 1079, IS 5986, IS 513(pt-1 & 2))(N - IS 228) |
- |
0 |
|
- |
| 7.1 (As per IS 1079, IS 5986, IS 513(pt-1 & 2))(Al - IS 228) |
- |
0 |
|
- |
| 7.1 (As per IS 1079, IS 5986, IS 513(pt-1 & 2))(Si - IS 228) |
- |
0 |
|
- |
| 7.1 (As per IS 1079, IS 5986, IS 513(pt-1 & 2))(Cu - IS 228) |
- |
0 |
|
- |
| 7.1 (As per IS 1079, IS 5986, IS 513(pt-1 & 2))(Micro alloy element- IS 228) |
- |
0 |
|
- |
| 7.1 (As per IS 1079, IS 5986, IS 513(pt-1 & 2))(Boron in micro alloy element- IS 228) |
- |
0 |
|
- |
| 7.1 (As per IS 5986)(CE- IS 228) |
- |
0 |
|
- |
| 8.3.1 (As per IS 1079, IS 5986, IS 513(pt-1 & 2))(Yield strength - IS 1608(Pt-1)) |
- |
0 |
|
- |
| 8.3.1 (As per IS 1079, IS 5986, IS 513(pt-1 & 2))(Tensile Strength - IS 1608(Pt-1)) |
- |
0 |
|
- |
| 8.3.1 (As per IS 1079, IS 5986, IS 513(pt-1 & 2))(Elongation - IS 1608(Pt-1)) |
- |
0 |
|
- |
| 9.1, 9.1.1-Table 1(Coating Mass per Surface, Min - IS 12860 & IS 6745) |
- |
0 |
|
- |
| 9.1, 9.1.1-Table 1(Coating Mass per Surface, Max - IS 12860 & IS 6746) |
- |
0 |
|
- |
| 9.2.2-Table 2(Coating Adhesion Test- IS 17404) |
- |
0 |
|
- |
| 10.1(Coil Internal Diameter-IS17404) |
- |
0 |
|
- |
| 10.2 (As per IS 1079, IS 5986, IS 513(pt-1 & 2))(Width) |
- |
0 |
|
- |
| 10.2 (As per IS 1079, IS 5986, IS 513(pt-1 & 2))(Length) |
- |
0 |
|
- |
| 10.2 (As per IS 1079, IS 5986, IS 513(pt-1 & 2))(Thickness) |
- |
0 |
|
- |
| 7.1 (As per IS 1079, IS 5986, IS 513(pt-1 & 2))(C -IS 228) |
- |
0 |
|
- |
| 7.1 (As per IS 1079, IS 5986, IS 513(pt-1 & 2))(Mn - IS 228) |
- |
0 |
|
- |
| 7.1 (As per IS 1079, IS 5986, IS 513(pt-1 & 2))(P - IS 228 ) |
- |
0 |
|
- |
| 7.1 (As per IS 1079, IS 5986, IS 513(pt-1 & 2))(S - IS 228) |
- |
0 |
|
- |
| 7.1 (As per IS 1079, IS 5986, IS 513(pt-1 & 2))(N - IS 228) |
- |
0 |
|
- |
| 7.1 (As per IS 1079, IS 5986, IS 513(pt-1 & 2))(Al - IS 228) |
- |
0 |
|
- |
| 7.1 (As per IS 1079, IS 5986, IS 513(pt-1 & 2))(Si - IS 228) |
- |
0 |
|
- |
| 7.1 (As per IS 1079, IS 5986, IS 513(pt-1 & 2))(Cu - IS 228) |
- |
0 |
|
- |
| 7.1 (As per IS 1079, IS 5986, IS 513(pt-1 & 2))(Micro alloy element- IS 228) |
- |
0 |
|
- |
| 7.1 (As per IS 1079, IS 5986, IS 513(pt-1 & 2))(Boron in micro alloy element- IS 228) |
- |
0 |
|
- |
| 7.1 (As per IS 5986)(CE- IS 228) |
- |
0 |
|
- |
| 8.3.1 (As per IS 1079, IS 5986, IS 513(pt-1 & 2))(Yield strength - IS 1608(Pt-1)) |
- |
0 |
|
- |
| 8.3.1 (As per IS 1079, IS 5986, IS 513(pt-1 & 2))(Tensile Strength - IS 1608(Pt-1)) |
- |
0 |
|
- |
| 8.3.1 (As per IS 1079, IS 5986, IS 513(pt-1 & 2))(Elongation - IS 1608(Pt-1)) |
- |
0 |
|
- |
| 9.1, 9.1.1-Table 1(Coating Mass per Surface, Min - IS 12860 & IS 6745) |
- |
0 |
|
- |
| 9.1, 9.1.1-Table 1(Coating Mass per Surface, Max - IS 12860 & IS 6746) |
- |
0 |
|
- |
| 9.2.2-Table 2(Coating Adhesion Test- IS 17404) |
- |
0 |
|
- |
| 10.1(Coil Internal Diameter-IS17404) |
- |
0 |
|
- |
| 10.2 (As per IS 1079, IS 5986, IS 513(pt-1 & 2))(Width) |
- |
0 |
|
- |
| 10.2 (As per IS 1079, IS 5986, IS 513(pt-1 & 2))(Length) |
- |
0 |
|
- |
| 10.2 (As per IS 1079, IS 5986, IS 513(pt-1 & 2))(Thickness) |
- |
0 |
|
- |
| 7.1 (As per IS 1079, IS 5986, IS 513(pt-1 & 2))(C -IS 228) |
- |
0 |
|
- |
| 7.1 (As per IS 1079, IS 5986, IS 513(pt-1 & 2))(Mn - IS 228) |
- |
0 |
|
- |
| 7.1 (As per IS 1079, IS 5986, IS 513(pt-1 & 2))(P - IS 228 ) |
- |
0 |
|
- |
| 7.1 (As per IS 1079, IS 5986, IS 513(pt-1 & 2))(S - IS 228) |
- |
0 |
|
- |
| 7.1 (As per IS 1079, IS 5986, IS 513(pt-1 & 2))(N - IS 228) |
- |
0 |
|
- |
| 7.1 (As per IS 1079, IS 5986, IS 513(pt-1 & 2))(Al - IS 228) |
- |
0 |
|
- |
| 7.1 (As per IS 1079, IS 5986, IS 513(pt-1 & 2))(Si - IS 228) |
- |
0 |
|
- |
| 7.1 (As per IS 1079, IS 5986, IS 513(pt-1 & 2))(Cu - IS 228) |
- |
0 |
|
- |
| 7.1 (As per IS 1079, IS 5986, IS 513(pt-1 & 2))(Micro alloy element- IS 228) |
- |
0 |
|
- |
| 7.1 (As per IS 1079, IS 5986, IS 513(pt-1 & 2))(Boron in micro alloy element- IS 228) |
- |
0 |
|
- |
| 7.1 (As per IS 5986)(CE- IS 228) |
- |
0 |
|
- |
| 8.3.1 (As per IS 1079, IS 5986, IS 513(pt-1 & 2))(Yield strength - IS 1608(Pt-1)) |
- |
0 |
|
- |
| 8.3.1 (As per IS 1079, IS 5986, IS 513(pt-1 & 2))(Tensile Strength - IS 1608(Pt-1)) |
- |
0 |
|
- |
| 8.3.1 (As per IS 1079, IS 5986, IS 513(pt-1 & 2))(Elongation - IS 1608(Pt-1)) |
- |
0 |
|
- |
| 9.1, 9.1.1-Table 1(Coating Mass per Surface, Min - IS 12860 & IS 6745) |
- |
0 |
|
- |
| 9.1, 9.1.1-Table 1(Coating Mass per Surface, Max - IS 12860 & IS 6746) |
- |
0 |
|
- |
| 9.2.2-Table 2(Coating Adhesion Test- IS 17404) |
- |
0 |
|
- |
| 10.1(Coil Internal Diameter-IS17404) |
- |
0 |
|
- |
| 10.2 (As per IS 1079, IS 5986, IS 513(pt-1 & 2))(Width) |
- |
0 |
|
- |
| 10.2 (As per IS 1079, IS 5986, IS 513(pt-1 & 2))(Length) |
- |
0 |
|
- |
| 10.2 (As per IS 1079, IS 5986, IS 513(pt-1 & 2))(Thickness) |
- |
0 |
|
- |
| 7.1 (As per IS 1079, IS 5986, IS 513(pt-1 & 2))(C -IS 228) |
- |
0 |
|
- |
| 7.1 (As per IS 1079, IS 5986, IS 513(pt-1 & 2))(Mn - IS 228) |
- |
0 |
|
- |
| 7.1 (As per IS 1079, IS 5986, IS 513(pt-1 & 2))(P - IS 228 ) |
- |
0 |
|
- |
| 7.1 (As per IS 1079, IS 5986, IS 513(pt-1 & 2))(S - IS 228) |
- |
0 |
|
- |
| 7.1 (As per IS 1079, IS 5986, IS 513(pt-1 & 2))(N - IS 228) |
- |
0 |
|
- |
| 7.1 (As per IS 1079, IS 5986, IS 513(pt-1 & 2))(Al - IS 228) |
- |
0 |
|
- |
| 7.1 (As per IS 1079, IS 5986, IS 513(pt-1 & 2))(Si - IS 228) |
- |
0 |
|
- |
| 7.1 (As per IS 1079, IS 5986, IS 513(pt-1 & 2))(Cu - IS 228) |
- |
0 |
|
- |
| 7.1 (As per IS 1079, IS 5986, IS 513(pt-1 & 2))(Micro alloy element- IS 228) |
- |
0 |
|
- |
| 7.1 (As per IS 1079, IS 5986, IS 513(pt-1 & 2))(Boron in micro alloy element- IS 228) |
- |
0 |
|
- |
| 7.1 (As per IS 5986)(CE- IS 228) |
- |
0 |
|
- |
| 8.3.1 (As per IS 1079, IS 5986, IS 513(pt-1 & 2))(Yield strength - IS 1608(Pt-1)) |
- |
0 |
|
- |
| 8.3.1 (As per IS 1079, IS 5986, IS 513(pt-1 & 2))(Tensile Strength - IS 1608(Pt-1)) |
- |
0 |
|
- |
| 8.3.1 (As per IS 1079, IS 5986, IS 513(pt-1 & 2))(Elongation - IS 1608(Pt-1)) |
- |
0 |
|
- |
| 9.1, 9.1.1-Table 1(Coating Mass per Surface, Min - IS 12860 & IS 6745) |
- |
0 |
|
- |
| 9.1, 9.1.1-Table 1(Coating Mass per Surface, Max - IS 12860 & IS 6746) |
- |
0 |
|
- |
| 9.2.2-Table 2(Coating Adhesion Test- IS 17404) |
- |
0 |
|
- |
| 10.1(Coil Internal Diameter-IS17404) |
- |
0 |
|
- |
| 10.2 (As per IS 1079, IS 5986, IS 513(pt-1 & 2))(Width) |
- |
0 |
|
- |
| 10.2 (As per IS 1079, IS 5986, IS 513(pt-1 & 2))(Length) |
- |
0 |
|
- |
| 10.2 (As per IS 1079, IS 5986, IS 513(pt-1 & 2))(Thickness) |
- |
0 |
|
- |
|
- |
- Included w.e.f 22.07.2025 |
| 7244 |
PLANET ANALYSIS PRIVATE LIMITED, KANPUR
| 9125906
| IS 15298 : part 4 (2024) |
Personal Protective Equipment Part 4 Occupational Footwear (ISO 20347 : 2021, MOD) (Third Revision) |
- |
41000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl 5.2(Design) |
- |
300 |
|
5 % DISCOUNT to BIS Sample only
Basic Test Charges Rs.41000.00
(Mechanical Test-Rs 14000.00, Chemical Test-Rs 27000.00) Additional Parameter Rs. 7500.00 as whole Individual additional parameter as per clausewise RATE |
| Cl 5.2.2(" Height of upper
") |
- |
200 |
|
5 % DISCOUNT to BIS Sample only
Basic Test Charges Rs.41000.00
(Mechanical Test-Rs 14000.00, Chemical Test-Rs 27000.00) Additional Parameter Rs. 7500.00 as whole Individual additional parameter as per clausewise RATE |
| Cl 5.2.3(Heel area) |
- |
200 |
|
- |
| Cl 5.3.1.1(Construction of whole footwear) |
- |
300 |
|
- |
| Cl 5.3.1.2(Upper/outsole bond strength) |
- |
600 |
|
- |
| Cl 5.3.2(Leak proofness) |
- |
500 |
|
- |
| Cl 5.3.3(Specific ergonomic features) |
- |
500 |
|
- |
| Cl 5.3.4.2(Slip resistance on ceramic tile floor with sodium lauryl sulphate (NaLS) solution) |
- |
1500 |
|
- |
| Cl 5.3.5, Table no 1 of IS 17011,(i)(Allergenic and carcinogenic disperse dyes) |
- |
2500 |
|
- |
| Cl 5.3.5, Table no 1 of IS 17011 (ii)(Aromatic amines released from Azo dyes (each individual amine)) |
- |
3000 |
|
- |
| Cl 5.3.5, Table no 1 of IS 17011 (iii)(Aromatic amines released from Azo dyes (each individual amine)) |
- |
3000 |
|
- |
| Cl 5.3.5, Table no 1 of IS 17011 (iv)(Chromium (VI)) |
- |
2000 |
|
- |
| Cl 5.3.5, Table no 1 of IS 17011 (v)(Dimethyl fumarate (DMFU)) |
- |
2500 |
|
- |
| Cl 5.3.5, Table no1 of IS 17011 (vi)(Formaldehyde (free or released by partial hydrolysis)) |
- |
1000 |
|
- |
| Cl 5.3.5, Table no 1 of IS 17011 (vii)(Formaldehyde) |
- |
1000 |
|
- |
| Cl 5.3.5, Table no 1 of IS 17011 (viii)(Organotin compounds) |
- |
3000 |
|
- |
| Cl 5.3.5, Table no 1 of IS 17011 (ix)(PCP-TeCP-TriCP polychlorophenols) |
- |
3000 |
|
- |
| Cl 5.3.5, Table no 1 of IS 17011 (x)(pH) |
- |
500 |
|
- |
| Cl 5.3.5, Table no 1 of IS 17011 (xi)(Phthalates (each individual phthalate)) |
- |
4000 |
|
- |
| Cl 5.3.5, Table no 1 of IS 17011 (xii)(Nickel, on skin contact) |
- |
1500 |
|
- |
| Cl 5.3.6(Seam strength) |
- |
500 |
|
- |
| Cl 5.3.7(Lead Content ( National Annex A)) |
- |
1000 |
|
- |
| Cl 5.4.1.1(Class I footwear, determination of the area where upper requirements apply of Upper) |
- |
300 |
|
- |
| Cl 5.4.1.2(Hybrid footwear, determination of the area where upper requirements apply of Upper) |
- |
300 |
|
- |
| Cl 5.4.2(Thickness) |
- |
300 |
|
- |
| Cl 5.4.3(Tear strength) |
- |
500 |
|
- |
| Cl 5.4.4, Table 9(Tensile properties- Tensile strength) |
- |
500 |
|
- |
| Cl 5.4.4, Table 9(Tensile properties- Breaking Force) |
- |
500 |
|
- |
| Cl 5.4.4, Table 9(Tensile properties-Modulus at 100 % elongation) |
- |
500 |
|
- |
| Cl 5.4.4, Table 9(Tensile properties- Elongation at break) |
- |
250 |
|
- |
| Cl 5.4.5(Flexing resistance) |
- |
750 |
|
- |
| Cl 5.4.6(Water vapour permeability and coefficient) |
- |
800 |
|
- |
| Cl 5.4.7(Resistance to hydrolysis) |
- |
2000 |
|
- |
| Cl 5.5.2(Lining- Tear strength) |
- |
500 |
|
- |
| Cl 5.5.3(Lining- Abrasion resistance) |
- |
1000 |
|
- |
| Cl 5.5.4(Lining-Water vapour permeability and coefficient) |
- |
800 |
|
- |
| Cl 5.6.2(Tear strength of tongue) |
- |
500 |
|
- |
| Cl 5.7.1(Thickness of Insole, insock and footbed) |
- |
300 |
|
- |
| Cl 5.7.2(Water permeability of insock) |
- |
500 |
|
- |
| Cl 5.7.3(Water absorption and desorption of Insole, insock and footbed) |
- |
600 |
|
- |
| Cl 5.7.4.1(Abrasion resistance of Insoles) |
- |
1000 |
|
- |
| Cl 5.7.4.2(Abrasion resistance of Insocks) |
- |
1000 |
|
- |
| Cl 5.8.2.1(Thickness of Outsole) |
- |
300 |
|
- |
| Cl 5.8.2.2(Cleated area) |
- |
300 |
|
- |
| Cl 5.8.2.3(Cleat height) |
- |
300 |
|
- |
| Cl 5.8.3(Outsole- Tear strength) |
- |
500 |
|
- |
| Cl 5.8.4(Outsole- Abrasion resistance) |
- |
800 |
|
- |
| Cl 5.8.5(Outsole-Flexing resistance) |
- |
800 |
|
- |
| Cl 5.8.6(Outsole-Resistance to hydrolysis) |
- |
1500 |
|
- |
| Cl 5.8.7(Interlayer bond strength) |
- |
600 |
|
- |
| Cl 6.2.1.1.2(Metallic perforation-resistant inserts (Type P)) |
- |
500 |
|
- |
| Cl 6.2.1.1.3(Non-metallic perforation-resistant inserts and insoles (Type PL)) |
- |
500 |
|
- |
| Cl 6.2.1.1.4(Non-metallic perforation-resistant inserts and insoles (Type PS)) |
- |
500 |
|
- |
| Cl 6.2.1.2(Construction of perforation resistant insert) |
- |
300 |
|
- |
| Cl 6.2.1.3(Dimensions of perforation resistant insert) |
- |
300 |
|
- |
| Cl 6.2.1.4.1(Flex resistance of perforation-resistant inserts) |
- |
1000 |
|
- |
| Cl 6.2.1.4.2.1(ISO 20344:2021, 5.11.2) |
- |
500 |
|
- |
| Cl 6.2.1.4.2.2(ISO 20344:2021, 5.6.2.1) |
- |
500 |
|
- |
| Cl 6.2.1.4.3(Stability against ageing and environmental influence of non-metallic perforationresistant inserts) |
- |
500 |
|
- |
| Cl 6.2.2.1(Electrical properties of Partially conductive footwear) |
- |
1000 |
|
- |
| Cl 6.2.2.2(Electrical properties of Antistatic footwear) |
- |
1000 |
|
- |
| Cl 6.2.3.1(Heat insulation of outsole complex) |
- |
500 |
|
- |
| Cl 6.2.3.2(Cold insulation of outsole complex) |
- |
800 |
|
- |
| Cl 6.2.4(Energy absorption of seat region) |
- |
500 |
|
- |
| Cl 6.2.5(Water resistance) |
- |
500 |
|
- |
| Cl 6.2.6(Ankle protection) |
- |
500 |
|
- |
| Cl 6.2.7.1(Cut resistance footwear- design) |
- |
500 |
|
- |
| Cl 6.2.7.2(Dimensions and construction of protective area of Cut resistance footwear) |
- |
300 |
|
- |
| Cl 6.2.7.3(Resistance to cutting) |
- |
500 |
|
- |
| Cl 6.2.8(Scuff cap) |
- |
600 |
|
- |
| Cl 6.2.9("Slip resistance on ceramic tile floor with glycerine
") |
- |
1500 |
|
- |
| Cl 6.3(Upper — Water penetration and absorption) |
- |
800 |
|
- |
| Cl 6.4.1(Resistance to hot contact - Outsole) |
- |
500 |
|
- |
| Cl 6.4.2(Resistance to fuel oil - Outsole) |
- |
600 |
|
- |
| Cl 6.4.3.1(Mechanical properties of Ladder grip) |
- |
800 |
|
- |
| Cl 6.4.3.2(Design of Ladder grip) |
- |
200 |
|
- |
| Cl 6.4.3.3(Cleat height in the waist area of Ladder grip) |
- |
300 |
|
- |
| Cl 6.4.3.4(Heel breast of Ladder grip) |
- |
300 |
|
- |
| Cl 7("Marking
") |
- |
0 |
|
5 % DISCOUNT to BIS Sample only
Basic Test Charges Rs.41000.00
(Mechanical Test-Rs 14000.00, Chemical Test-Rs 27000.00) Additional Parameter Rs. 7500.00 as whole Individual additional parameter as per clausewise RATE |
|
20 Jan, 2028 |
- - |
| 7245 |
Alpha Test House Private Limited, Delhi
| 8131026
| IS 302 : Part 2 : Sec 8 (2024) |
Household and Similar Electrical Appliances âSafety Part 2 Particular Requirements Section 8 Shavers, Hair Clippers and Similar Appliances (First Revision) |
- |
25000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 7(Marking and instructions) |
- |
500 |
|
- |
| 8(Protection against access to live parts) |
- |
500 |
|
- |
| 10(Power input and current) |
- |
1000 |
|
- |
| 11(Heating) |
- |
1000 |
|
- |
| 12(Charging of metal-ion batteries) |
- |
2000 |
|
- |
| 13.1 &13.2(Leakage current test) |
- |
1000 |
|
- |
| 13.1 &13.3(Electric strength test) |
- |
1000 |
|
- |
| 14(Transient overvoltages) |
- |
1000 |
|
- |
| 15(Moisture resistance) |
- |
2000 |
|
- |
| 15.3(Moisture resistance) |
- |
500 |
|
- |
| 16.1 &16.2(Leakage current test) |
- |
500 |
|
- |
| 16.1 & 16.3(Electric strength test) |
- |
500 |
|
- |
| 17(Overload protection of transformers and associated circuits) |
- |
200 |
|
- |
| 19.1 to 19.13, Table No. - 9(Abnormal operation) |
- |
1500 |
|
- |
| 19.101(Abnormal operation) |
- |
500 |
|
- |
| 20.1(Stability and mechanical hazards) |
- |
500 |
|
- |
| 20.2(Stability and mechanical hazards) |
- |
200 |
|
- |
| 21(Mechanical strength) |
- |
500 |
|
- |
| 21.101(Mechanical strength) |
- |
300 |
|
- |
| 21.102(Mechanical strength) |
- |
300 |
|
- |
| 21.103(Mechanical strength) |
- |
500 |
|
- |
| 22(Construction) |
- |
500 |
|
- |
| 22.101(Construction) |
- |
500 |
|
- |
| 22.102(Construction) |
- |
500 |
|
- |
| 22.103(Construction) |
- |
500 |
|
- |
| 23(Internal wiring) |
- |
500 |
|
- |
| 24(Components) |
- |
500 |
|
- |
| 25("Supply connection and
external flexible cords") |
- |
500 |
|
- |
| 26("Terminals for external
conductors") |
- |
500 |
|
- |
| 27(Provision for earthing) |
- |
500 |
|
- |
| 28(Screws and connections) |
- |
500 |
|
- |
| 29("Clearances, creepage
distances and solid insulation") |
- |
1000 |
|
- |
| 30(Resistance to heat and fire) |
- |
1500 |
|
- |
| 31(Resistance to rusting) |
- |
1000 |
|
- |
| 32("Radiation, toxicity and similar
hazards") |
- |
500 |
|
- |
| 7(Marking and instructions) |
- |
0 |
|
- |
| 8(Protection against access to live parts) |
- |
0 |
|
- |
| 10(Power input and current) |
- |
0 |
|
- |
| 11(Heating) |
- |
0 |
|
- |
| 12(Charging of metal-ion batteries) |
- |
0 |
|
- |
| 13.1 &13.2(Leakage current test) |
- |
0 |
|
- |
| 13.1 &13.3(Electric strength test) |
- |
0 |
|
- |
| 14(Transient overvoltages) |
- |
0 |
|
- |
| 15(Moisture resistance) |
- |
0 |
|
- |
| 15.3(Moisture resistance) |
- |
0 |
|
- |
| 16.1 &16.2(Leakage current test) |
- |
0 |
|
- |
| 16.1 & 16.3(Electric strength test) |
- |
0 |
|
- |
| 17(Overload protection of transformers and associated circuits) |
- |
0 |
|
- |
| 19.1 to 19.13, Table No. - 9(Abnormal operation) |
- |
0 |
|
- |
| 19.101(Abnormal operation) |
- |
0 |
|
- |
| 20.1(Stability and mechanical hazards) |
- |
0 |
|
- |
| 20.2(Stability and mechanical hazards) |
- |
0 |
|
- |
| 21(Mechanical strength) |
- |
0 |
|
- |
| 21.101(Mechanical strength) |
- |
0 |
|
- |
| 21.102(Mechanical strength) |
- |
0 |
|
- |
| 21.103(Mechanical strength) |
- |
0 |
|
- |
| 22(Construction) |
- |
0 |
|
- |
| 22.101(Construction) |
- |
0 |
|
- |
| 22.102(Construction) |
- |
0 |
|
- |
| 22.103(Construction) |
- |
0 |
|
- |
| 23(Internal wiring) |
- |
0 |
|
- |
| 24(Components) |
- |
0 |
|
- |
| 25("Supply connection and
external flexible cords") |
- |
0 |
|
- |
| 26("Terminals for external
conductors") |
- |
0 |
|
- |
| 27(Provision for earthing) |
- |
0 |
|
- |
| 28(Screws and connections) |
- |
0 |
|
- |
| 29("Clearances, creepage
distances and solid insulation") |
- |
0 |
|
- |
| 30(Resistance to heat and fire) |
- |
0 |
|
- |
| 31(Resistance to rusting) |
- |
0 |
|
- |
| 32("Radiation, toxicity and similar
hazards") |
- |
0 |
|
- |
|
- |
- Included w.e.f 04.08.2025
Exclusion : Cl 19.11.4.1 to 19.11.4.7(EMI/EMC) |
| 7246 |
Gravitas Laboratories Private Limited, Greater Noida
| 8182606
| IS 15965 (2012) |
Pre - Painted aluminium zinc alloy metallic coated steel strip and sheet (Plain) |
All Thickness |
25000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl 7(Workmanship) |
- |
15000 |
|
- |
| Cl 8.3.1(Adhesion ) |
- |
15000 |
|
- |
| Cl 8.3.2(Impact Resistance) |
- |
15000 |
|
- |
| Cl 8.4(Load Resistance) |
- |
15000 |
|
- |
| Cl 8.7(Dry Film Thickness) |
- |
15000 |
|
- |
| Cl 9.1(Workmanship) |
- |
15000 |
|
- |
| Cl 10.1(Corrosion Test) |
- |
15000 |
|
- |
| Cl 10.2(Humidity Test) |
- |
15000 |
|
- |
| Cl 11(Length, Width & Thickness) |
- |
15000 |
|
- |
| Cl 12(Camber, Deviation From Squareness (Out-of- Square) & Deviation From Flatness) |
- |
15000 |
|
- |
| Cl 12(Weight) |
- |
15000 |
|
- |
| Cl 7(Workmanship) |
- |
0 |
|
- |
| Cl 8.3.1(Adhesion ) |
- |
0 |
|
- |
| Cl 8.3.2(Impact Resistance) |
- |
0 |
|
- |
| Cl 8.4(Load Resistance) |
- |
0 |
|
- |
| Cl 8.7(Dry Film Thickness) |
- |
0 |
|
- |
| Cl 9.1(Workmanship) |
- |
0 |
|
- |
| Cl 10.1(Corrosion Test) |
- |
0 |
|
- |
| Cl 10.2(Humidity Test) |
- |
0 |
|
- |
| Cl 11(Length, Width & Thickness) |
- |
0 |
|
- |
| Cl 12(Camber, Deviation From Squareness (Out-of- Square) & Deviation From Flatness) |
- |
0 |
|
- |
| Cl 13(Weight) |
- |
0 |
|
- |
| Cl 7(Workmanship) |
- |
0 |
|
- |
| Cl 8.3.1(Adhesion ) |
- |
0 |
|
- |
| Cl 8.3.2(Impact Resistance) |
- |
0 |
|
- |
| Cl 8.4(Load Resistance) |
- |
0 |
|
- |
| Cl 8.7(Dry Film Thickness) |
- |
0 |
|
- |
| Cl 9.1(Workmanship) |
- |
0 |
|
- |
| Cl 10.1(Corrosion Test) |
- |
0 |
|
- |
| Cl 10.2(Humidity Test) |
- |
0 |
|
- |
| Cl 11(Length, Width & Thickness) |
- |
0 |
|
- |
| Cl 12(Camber, Deviation From Squareness (Out-of- Square) & Deviation From Flatness) |
- |
0 |
|
- |
| Cl 12(Weight) |
- |
0 |
|
- |
| 8.6(Solvent Resistance test) |
- |
0 |
|
- |
| 9.2(colour) |
- |
15000 |
|
- |
| 9.3(Gloss (60 Deg)) |
- |
15000 |
|
- |
| 4, 5(CARBON) |
- |
10000 |
|
- |
| 4, 5(SULPHUR) |
- |
10000 |
|
- |
| 4, 5(PHOSPHURS) |
- |
10000 |
|
- |
| 4, 5(MANGANESE) |
- |
10000 |
|
- |
| 4, 5(NITROGEN) |
- |
10000 |
|
- |
| 4, 5(SILICON) |
- |
10000 |
|
- |
| 4, 5(ALUMINIUM) |
- |
10000 |
|
- |
| Cl 12(Weight) |
- |
0 |
|
- |
| Cl 12(Camber, Deviation From Squareness (Out-of- Square) & Deviation From Flatness) |
- |
0 |
|
- |
| Cl 11(Length, Width & Thickness) |
- |
0 |
|
- |
| Cl 10.2(Humidity Test) |
- |
0 |
|
- |
| Cl 10.1(Corrosion Test) |
- |
0 |
|
- |
| Cl 9.1(Workmanship) |
- |
0 |
|
- |
| Cl 8.7(Dry Film Thickness) |
- |
0 |
|
- |
| Cl 8.4(Load Resistance) |
- |
0 |
|
- |
| Cl 8.3.2(Impact Resistance) |
- |
0 |
|
- |
| Cl 8.3.1(Adhesion ) |
- |
0 |
|
- |
| Cl 7(Workmanship) |
- |
0 |
|
- |
| Cl 7(Workmanship) |
- |
0 |
|
- |
| Cl 8.3.1(Adhesion) |
- |
0 |
|
- |
| Cl 8.3.2(Impact Resistance) |
- |
0 |
|
- |
| Cl 8.4(Load Resistance) |
- |
0 |
|
- |
| Cl 8.7(Dry Film Thickness) |
- |
0 |
|
- |
| Cl 9.1(Workmanship) |
- |
0 |
|
- |
| Cl 10.1(Corrosion Test) |
- |
0 |
|
- |
| Cl 10.2(Humidity Test) |
- |
0 |
|
- |
| Cl 11(Length, Width & Thickness) |
- |
0 |
|
- |
| Cl 12(Camber, Deviation From Squareness (Out-of- Square) & Deviation From Flatness) |
- |
0 |
|
- |
| Cl 12(Weight) |
- |
0 |
|
- |
| 13(IS 15965) |
- |
0 |
|
- |
| 12.1(IS 15965) |
- |
0 |
|
- |
| 12.2(IS/ISO 16163) |
- |
0 |
|
- |
| 12.3(IS 15965) |
- |
0 |
|
- |
| 11.0(IS/ISO 16163) |
- |
0 |
|
- |
| 11.0(IS/ISO 16163) |
- |
0 |
|
- |
| 10.1(IS 9844) |
- |
0 |
|
- |
| 10.1(IS 9844) |
- |
0 |
|
- |
| 10.1(IS 9844) |
- |
0 |
|
- |
| 10.1(IS 9844) |
- |
0 |
|
- |
| 10.1(IS 9844) |
- |
0 |
|
- |
| 10.1(IS 9844) |
- |
0 |
|
- |
| 10.2(IS 101 Part 6 Sec 1) |
- |
0 |
|
- |
| 10.2(IS 101 Part 6 Sec 1) |
- |
0 |
|
- |
| 10.2(IS 101 Part 6 Sec 1) |
- |
0 |
|
- |
| 10.2(IS 101 Part 6 Sec 1) |
- |
0 |
|
- |
| 9.1(IS 15965) |
- |
0 |
|
- |
| 8.3.1(IS 15965) |
- |
0 |
|
- |
| 8.3.2(IS 15965) |
- |
0 |
|
- |
| 8.3.2(IS 15965) |
- |
0 |
|
- |
| 8.4(IS 101 Part 5 Sec 1) |
- |
0 |
|
- |
| 7 & 7.3(ISO 2808) |
- |
0 |
|
- |
| 7 & 7.3(ISO 2808) |
- |
0 |
|
- |
| 7 & 7.4(ISO 2808) |
- |
0 |
|
- |
| 13(Mass) |
- |
0 |
|
- |
| 12.1(Chamber) |
- |
0 |
|
- |
| 12.2(Deviation from Squareness (Out of square)) |
- |
0 |
|
- |
| 12.3(Deviation from flatness (Steepness)) |
- |
0 |
|
- |
| 11.0(Length) |
- |
0 |
|
- |
| 11.0(Width) |
- |
0 |
|
- |
| 11.0(Thickness) |
- |
0 |
|
- |
| 10.1(Corrosion resistance ( Rating for Failure at scribed and panel edge)) |
- |
0 |
|
- |
| 10.1(Corrosion resistance (Under cut at scribed Lines, Rating for failure at scribe & Panel edge)) |
- |
0 |
|
- |
| 10.1(Corrosion resistance (Corrosion of base metal, Degree of deterioration for the metal substrate)) |
- |
0 |
|
- |
| 10.1(Corrosion resistance (Rating for density of Blistering)) |
- |
0 |
|
- |
| 10.1(Corrosion resistance (Rating for size of Blisters)) |
- |
0 |
|
- |
| 10.2(Humidity resistance ( Rating for Failure at scribed and panel edge)) |
- |
0 |
|
- |
| 10.2(Humidity resistance (Under cut at scribed Lines, Rating for failure at scribe & Panel edge)) |
- |
0 |
|
- |
| 10.2(Humidity resistance (Rating for density of Blistering)) |
- |
0 |
|
- |
| 10.2(Humdity resistance (Rating for size of Blisters)) |
- |
0 |
|
- |
| 9.1(Appearance (General)) |
- |
0 |
|
- |
| 8.3.1(T bend Adhesion Test) |
- |
0 |
|
- |
| 8.3.2(Reverse Impact Resistance test) |
- |
0 |
|
- |
| 8.4(Pencile hardness test) |
- |
0 |
|
- |
| 7 & 7.3(Coating (Top Side)) |
- |
0 |
|
- |
| 7 & 7.3(Coating (Bottom Side)) |
- |
0 |
|
- |
| 7 & 7.4(Coating (Primer Coating)) |
- |
0 |
|
- |
| Cl 8.5(Scratch Resistance) |
- |
0 |
|
- |
| Cl 8.5(Scratch Resistance) |
- |
0 |
|
- |
| Cl 8.5(Scratch Resistance) |
- |
0 |
|
- |
| Cl 8.5(Scratch Resistance) |
- |
0 |
|
- |
| Cl 8.5(Scratch Resistance) |
- |
0 |
|
- |
| 8.5(IS 101 Part 5 Sec 2) |
- |
0 |
|
- |
| 8.5(Scratch Hardness Test) |
- |
0 |
|
- |
| Cl 7(Workmanship) |
- |
0 |
|
- |
| Cl 8.3.1(Adhesion ) |
- |
0 |
|
- |
| Cl 8.3.2(Impact Resistance) |
- |
0 |
|
- |
| Cl 8.4(Load Resistance) |
- |
0 |
|
- |
| Cl 8.7(Dry Film Thickness) |
- |
0 |
|
- |
| Cl 9.1(Workmanship) |
- |
0 |
|
- |
| Cl 10.1(Corrosion Test) |
- |
0 |
|
- |
| Cl 10.2(Humidity Test) |
- |
0 |
|
- |
| Cl 11(Length, Width & Thickness) |
- |
0 |
|
- |
| Cl 12(Camber, Deviation From Squareness (Out-of- Square) & Deviation From Flatness) |
- |
0 |
|
- |
| Cl 12(Weight) |
- |
0 |
|
- |
| Cl 7(Workmanship) |
- |
0 |
|
- |
| Cl 8.3.1(Adhesion ) |
- |
0 |
|
- |
| Cl 8.3.2(Impact Resistance) |
- |
0 |
|
- |
| Cl 8.4(Load Resistance) |
- |
0 |
|
- |
| Cl 8.7(Dry Film Thickness) |
- |
0 |
|
- |
| Cl 9.1(Workmanship) |
- |
0 |
|
- |
| Cl 10.1(Corrosion Test) |
- |
0 |
|
- |
| Cl 10.2(Humidity Test) |
- |
0 |
|
- |
| Cl 11(Length, Width & Thickness) |
- |
0 |
|
- |
| Cl 12(Camber, Deviation From Squareness (Out-of- Square) & Deviation From Flatness) |
- |
0 |
|
- |
| Cl 13(Weight) |
- |
0 |
|
- |
| Cl 7(Workmanship) |
- |
0 |
|
- |
| Cl 8.3.1(Adhesion ) |
- |
0 |
|
- |
| Cl 8.3.2(Impact Resistance) |
- |
0 |
|
- |
| Cl 8.4(Load Resistance) |
- |
0 |
|
- |
| Cl 8.7(Dry Film Thickness) |
- |
0 |
|
- |
| Cl 9.1(Workmanship) |
- |
0 |
|
- |
| Cl 10.1(Corrosion Test) |
- |
0 |
|
- |
| Cl 10.2(Humidity Test) |
- |
0 |
|
- |
| Cl 11(Length, Width & Thickness) |
- |
0 |
|
- |
| Cl 12(Camber, Deviation From Squareness (Out-of- Square) & Deviation From Flatness) |
- |
0 |
|
- |
| Cl 12(Weight) |
- |
0 |
|
- |
| 8.6(Solvent Resistance test) |
- |
0 |
|
- |
| 9.2(colour) |
- |
0 |
|
- |
| 9.3(Gloss (60 Deg)) |
- |
0 |
|
- |
| 4, 5(CARBON) |
- |
0 |
|
- |
| 4, 5(SULPHUR) |
- |
0 |
|
- |
| 4, 5(PHOSPHURS) |
- |
0 |
|
- |
| 4, 5(MANGANESE) |
- |
0 |
|
- |
| 4, 5(NITROGEN) |
- |
0 |
|
- |
| 4, 5(SILICON) |
- |
0 |
|
- |
| 4, 5(ALUMINIUM) |
- |
0 |
|
- |
| Cl 12(Weight) |
- |
0 |
|
- |
| Cl 12(Camber, Deviation From Squareness (Out-of- Square) & Deviation From Flatness) |
- |
0 |
|
- |
| Cl 11(Length, Width & Thickness) |
- |
0 |
|
- |
| Cl 10.2(Humidity Test) |
- |
0 |
|
- |
| Cl 10.1(Corrosion Test) |
- |
0 |
|
- |
| Cl 9.1(Workmanship) |
- |
0 |
|
- |
| Cl 8.7(Dry Film Thickness) |
- |
0 |
|
- |
| Cl 8.4(Load Resistance) |
- |
0 |
|
- |
| Cl 8.3.2(Impact Resistance) |
- |
0 |
|
- |
| Cl 8.3.1(Adhesion ) |
- |
0 |
|
- |
| Cl 7(Workmanship) |
- |
0 |
|
- |
| Cl 7(Workmanship) |
- |
0 |
|
- |
| Cl 8.3.1(Adhesion) |
- |
0 |
|
- |
| Cl 8.3.2(Impact Resistance) |
- |
0 |
|
- |
| Cl 8.4(Load Resistance) |
- |
0 |
|
- |
| Cl 8.7(Dry Film Thickness) |
- |
0 |
|
- |
| Cl 9.1(Workmanship) |
- |
0 |
|
- |
| Cl 10.1(Corrosion Test) |
- |
0 |
|
- |
| Cl 10.2(Humidity Test) |
- |
0 |
|
- |
| Cl 11(Length, Width & Thickness) |
- |
0 |
|
- |
| Cl 12(Camber, Deviation From Squareness (Out-of- Square) & Deviation From Flatness) |
- |
0 |
|
- |
| Cl 12(Weight) |
- |
0 |
|
- |
| 13(IS 15965) |
- |
0 |
|
- |
| 12.1(IS 15965) |
- |
0 |
|
- |
| 12.2(IS/ISO 16163) |
- |
0 |
|
- |
| 12.3(IS 15965) |
- |
0 |
|
- |
| 11.0(IS/ISO 16163) |
- |
0 |
|
- |
| 11.0(IS/ISO 16163) |
- |
0 |
|
- |
| 10.1(IS 9844) |
- |
0 |
|
- |
| 10.1(IS 9844) |
- |
0 |
|
- |
| 10.1(IS 9844) |
- |
0 |
|
- |
| 10.1(IS 9844) |
- |
0 |
|
- |
| 10.1(IS 9844) |
- |
0 |
|
- |
| 10.1(IS 9844) |
- |
0 |
|
- |
| 10.2(IS 101 Part 6 Sec 1) |
- |
0 |
|
- |
| 10.2(IS 101 Part 6 Sec 1) |
- |
0 |
|
- |
| 10.2(IS 101 Part 6 Sec 1) |
- |
0 |
|
- |
| 10.2(IS 101 Part 6 Sec 1) |
- |
0 |
|
- |
| 9.1(IS 15965) |
- |
0 |
|
- |
| 8.3.1(IS 15965) |
- |
0 |
|
- |
| 8.3.2(IS 15965) |
- |
0 |
|
- |
| 8.3.2(IS 15965) |
- |
0 |
|
- |
| 8.4(IS 101 Part 5 Sec 1) |
- |
0 |
|
- |
| 7 & 7.3(ISO 2808) |
- |
0 |
|
- |
| 7 & 7.3(ISO 2808) |
- |
0 |
|
- |
| 7 & 7.4(ISO 2808) |
- |
0 |
|
- |
| 13(Mass) |
- |
0 |
|
- |
| 12.1(Chamber) |
- |
0 |
|
- |
| 12.2(Deviation from Squareness (Out of square)) |
- |
0 |
|
- |
| 12.3(Deviation from flatness (Steepness)) |
- |
0 |
|
- |
| 11.0(Length) |
- |
0 |
|
- |
| 11.0(Width) |
- |
0 |
|
- |
| 11.0(Thickness) |
- |
0 |
|
- |
| 10.1(Corrosion resistance ( Rating for Failure at scribed and panel edge)) |
- |
0 |
|
- |
| 10.1(Corrosion resistance (Under cut at scribed Lines, Rating for failure at scribe & Panel edge)) |
- |
0 |
|
- |
| 10.1(Corrosion resistance (Corrosion of base metal, Degree of deterioration for the metal substrate)) |
- |
0 |
|
- |
| 10.1(Corrosion resistance (Rating for density of Blistering)) |
- |
0 |
|
- |
| 10.1(Corrosion resistance (Rating for size of Blisters)) |
- |
0 |
|
- |
| 10.2(Humidity resistance ( Rating for Failure at scribed and panel edge)) |
- |
0 |
|
- |
| 10.2(Humidity resistance (Under cut at scribed Lines, Rating for failure at scribe & Panel edge)) |
- |
0 |
|
- |
| 10.2(Humidity resistance (Rating for density of Blistering)) |
- |
0 |
|
- |
| 10.2(Humdity resistance (Rating for size of Blisters)) |
- |
0 |
|
- |
| 9.1(Appearance (General)) |
- |
0 |
|
- |
| 8.3.1(T bend Adhesion Test) |
- |
0 |
|
- |
| 8.3.2(Reverse Impact Resistance test) |
- |
0 |
|
- |
| 8.4(Pencile hardness test) |
- |
0 |
|
- |
| 7 & 7.3(Coating (Top Side)) |
- |
0 |
|
- |
| 7 & 7.3(Coating (Bottom Side)) |
- |
0 |
|
- |
| 7 & 7.4(Coating (Primer Coating)) |
- |
0 |
|
- |
| Cl 8.5(Scratch Resistance) |
- |
0 |
|
- |
| Cl 8.5(Scratch Resistance) |
- |
0 |
|
- |
| Cl 8.5(Scratch Resistance) |
- |
0 |
|
- |
| Cl 8.5(Scratch Resistance) |
- |
0 |
|
- |
| Cl 8.5(Scratch Resistance) |
- |
0 |
|
- |
| 8.5(IS 101 Part 5 Sec 2) |
- |
0 |
|
- |
| 8.5(Scratch Hardness Test) |
- |
0 |
|
- |
|
- |
- Included w.e.f 11.07.2025 |
| 7247 |
BLUESKY LAB LLP, GHAZIABAD
| 8170306
| IS 302 : Part 2 : SEC 31 (2009) |
Safety of household and similar electrical appliances: Part 2 particular requirements: Sec 31 range hoods |
- |
25000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Clause No - 5(GENERAL CONDITIONS FOR THE TESTS) |
- |
500 |
|
30% discount offered to BIS |
| Clause No - 5.18(linear and angular dimension) |
- |
500 |
|
30% discount offered to BIS |
| Clause No - 6.2(harmfull ingress of water) |
- |
500 |
|
30% discount offered to BIS |
| Clause No - 8.1.1("PROTECTION AGAINST ACCESS TO LIVE
PART- test probe B") |
- |
500 |
|
30% discount offered to BIS |
| Clause No - 8.1.2("PROTECTION AGAINST ACCESS TO LIVE
PART - test probe 13") |
- |
500 |
|
30% discount offered to BIS |
| Clause No - 8.2(Addition) |
- |
2000 |
|
30% discount offered to BIS |
| Clause No - 10.1, Table No. -1(power input deviation) |
- |
2000 |
|
30% discount offered to BIS |
| Clause No - 13.3("LEAKAGE CURRENT AND ELECTRIC
STRENGTH AT OPERATING TEMPERATURE") |
- |
2000 |
|
30% discount offered to BIS |
| Clause No - 14(Impulse test voltage) |
- |
1000 |
|
30% discount offered to BIS |
| Clause No - 15.1.1(MOISTURE RESISTANCE) |
- |
1000 |
|
30% discount offered to BIS |
| Clause No -19.7(test is repeated with the capacitor short circuited) |
- |
1000 |
|
30% discount offered to BIS |
| Clause No -21.1(Mechanical strength) |
- |
1000 |
|
30% discount offered to BIS |
| Clause No -22.1(construction) |
- |
2000 |
|
30% discount offered to BIS |
| Clause No -22.11(push force applied) |
- |
2000 |
|
30% discount offered to BIS |
| Clause No -25.8, Table no -11(conductor resistance) |
- |
2000 |
|
30% discount offered to BIS |
| Clause No -25.5(dimension for pins) |
- |
2000 |
|
30% discount offered to BIS |
| Clause No -27.6(for circuit board) |
- |
2000 |
|
30% discount offered to BIS |
| Clause No -29.2(comparative tracking index) |
- |
2000 |
|
30% discount offered to BIS |
| Clause No -29.3.3(dry heat test) |
- |
2000 |
|
30% discount offered to BIS |
| Clause No -30.2.1(glow wire test) |
- |
2000 |
|
30% discount offered to BIS |
| Clause No -30.101("incorporate combustible
material") |
- |
2000 |
|
30% discount offered to BIS |
| 15(MOISTURE RESISTANCE) |
- |
2000 |
|
30% discount offered to BIS |
| 16(LEAKAGE CURRENT AND ELECTRIC STRENGTH) |
- |
2000 |
|
30% discount offered to BIS |
| 17(OVERLOAD PROTECTION OF TRANSFORMERS AND ASSOCIATED CIRCUITS) |
- |
2000 |
|
30% discount offered to BIS |
| 18(ENDURANCE) |
- |
1000 |
|
30% discount offered to BIS |
| 28(SCREWS AND CONNECTIONS) |
- |
1000 |
|
30% discount offered to BIS |
| 31(RESISTANCE TO RUSTING) |
- |
1000 |
|
30% discount offered to BIS |
| Clause No -19.11.4.4(Voltage dips and interruption) |
- |
1000 |
|
30% discount offered to BIS |
| Clause No - 13.3,Table No.- 4(voltage for electrical strength) |
- |
1000 |
|
30% discount offered to BIS |
|
22 May, 2028 |
- Included w.e.f.025.03.2025
Exclusion
Clause No -19.11.4.1 to Clause No -19.11.4.3 (EMI/EMC)
Clause No -24.1.2 (safety isolating transformer)
Clause No -24.1.3 (for switches)
Clause No -24.1.5 (for innterconnection couplers)
Clause No -24.4 (plug and socket) |
| 7248 |
Gravitas Laboratories Private Limited, Greater Noida
| 8182606
| IS 14246 (2024) |
CONTINUOUSLY PRE-PAINTED GALVANIZED STEEL SHEETS AND STRIPS - SPECIFICATION Second Revision |
All size |
25000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl-4.3(Organic Coating) |
- |
1000 |
|
- |
| Cl-4.4(Dry Film Thickness) |
- |
1000 |
|
- |
| Cl-6.1(Sampling of Test Specimen) |
- |
1000 |
|
- |
| Cl-6.2.3(Bend Test) |
- |
1000 |
|
- |
| Cl-6.3.1(Pencil Hardness Test) |
- |
1000 |
|
- |
| Cl-6.4(Impact Resistance Test) |
- |
1000 |
|
- |
| Cl-6.5(Cross Hatch Test) |
- |
1000 |
|
- |
| Cl-6.6(Solvent Resistance Test) |
- |
1000 |
|
- |
| Cl-7.3.1(Gloss) |
- |
1000 |
|
- |
| Cl-7.3.2(Colour) |
- |
1000 |
|
- |
| Cl-8.1, Table-4 (ii)(Corrosion of the base metal) |
- |
1000 |
|
- |
| Cl-8.1, Table-4 (iii)(Blistering) |
- |
1000 |
|
- |
| Cl-8.1, Table-4 (i)(Undercut at scribed lines) |
- |
1000 |
|
- |
| Cl-8.2 Table 5 (i)(Undercut at scribed lines) |
- |
1000 |
|
- |
| Cl-8.2 Table 5 (ii)(Blistering) |
- |
1000 |
|
- |
| Cl-9.1(The nominal thickness of sheets) |
- |
1000 |
|
- |
| Cl-9.2(The case of strips) |
- |
1000 |
|
- |
| Cl-10.1(Camber) |
- |
1000 |
|
- |
| Cl-10.2(Deviation from Squareness (Out-of Square) |
- |
1000 |
|
- |
| Cl-10.3(Deviation from Flatness) |
- |
1000 |
|
- |
| Cl-9.4.4(Mass) |
- |
1000 |
|
- |
| Cl-9.4.1(Tolerances on thickness sheets and strips) |
- |
1000 |
|
- |
| Cl-9.4.2(Width) |
- |
1000 |
|
- |
| Cl-9.4.3(Length) |
- |
1000 |
|
- |
| Cl-4.3(Organic Coating) |
- |
0 |
|
- |
| Cl-4.4(Dry Film Thickness) |
- |
0 |
|
- |
| Cl-6.1(Sampling of Test Specimen) |
- |
0 |
|
- |
| Cl-6.2.3(Bend Test) |
- |
0 |
|
- |
| Cl-6.3.1(Pencil Hardness Test) |
- |
0 |
|
- |
| Cl-6.4(Impact Resistance Test) |
- |
0 |
|
- |
| Cl-6.5(Cross Hatch Test) |
- |
0 |
|
- |
| Cl-6.6(Solvent Resistance Test) |
- |
0 |
|
- |
| Cl-7.3.1(Gloss) |
- |
0 |
|
- |
| Cl-7.3.2(Colour) |
- |
0 |
|
- |
| Cl-8.1, Table-4 (ii)(Corrosion of the base metal) |
- |
0 |
|
- |
| Cl-8.1, Table-4 (iii)(Blistering) |
- |
0 |
|
- |
| Cl-8.1, Table-4 (i)(Undercut at scribed lines) |
- |
0 |
|
- |
| Cl-8.2 Table 5 (i)(Undercut at scribed lines) |
- |
0 |
|
- |
| Cl-8.2 Table 5 (ii)(Blistering) |
- |
0 |
|
- |
| Cl-9.1(The nominal thickness of sheets) |
- |
0 |
|
- |
| Cl-9.2(The case of strips) |
- |
0 |
|
- |
| Cl-10.1(Camber) |
- |
0 |
|
- |
| Cl-10.2(Deviation from Squareness (Out-of Square) |
- |
0 |
|
- |
| Cl-10.3(Deviation from Flatness) |
- |
0 |
|
- |
| Cl-9.3(Mass of each pack) |
- |
0 |
|
- |
| Cl-9.4.1(Tolerances on thickness sheets and strips) |
- |
0 |
|
- |
| Cl-9.4.2(Width) |
- |
0 |
|
- |
| Cl-9.4.3(Length) |
- |
0 |
|
- |
| As per Cl.4.1(Carbon) |
- |
0 |
|
- |
| As per Cl.4.1(Sulphur) |
- |
0 |
|
- |
| As per Cl.4.1(Phosphorus) |
- |
0 |
|
- |
| As per Cl.4.1(Manganese) |
- |
0 |
|
- |
| As per Cl.4.1(Nitrogen) |
- |
0 |
|
- |
| As per Cl.4.1(Silicon) |
- |
0 |
|
- |
| As per Cl.4.1(Aluminium) |
- |
0 |
|
- |
| As per Cl.4.1(Vanadium) |
- |
0 |
|
- |
| As per Cl.4.1(Niobium) |
- |
0 |
|
- |
| As per Cl.4.1(Copper) |
- |
0 |
|
- |
| As per Cl.4.1(Titanium) |
- |
0 |
|
- |
| As per Cl.4.1(Boron) |
- |
0 |
|
- |
|
- |
- Included w.e.f 30.05.2025 |
| 7249 |
Planet Electro Labs Private Limited, Wazirpur
| 8185226
| IS 302 : Part 2 : SEC 31 (2009) |
Safety of household and similar electrical appliances: Part 2 particular requirements: Sec 31 range hoods |
- |
34000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Clause No - 8.1.1("PROTECTION AGAINST ACCESS TO LIVE
PART- test probe B") |
- |
700 |
|
N/A |
| Clause No - 8.1.2("PROTECTION AGAINST ACCESS TO LIVE
PART - test probe 13") |
- |
700 |
|
N/A |
| Clause No - 8.2(Addition) |
- |
600 |
|
N/A |
| Clause No - 10.1, Table No. -1(power input deviation) |
- |
5000 |
|
N/A |
| Clause No - 13.3("LEAKAGE CURRENT AND ELECTRIC
STRENGTH AT OPERATING TEMPERATURE") |
- |
5000 |
|
N/A |
| Clause No - 13.3,Table No.- 4(voltage for electrical strength) |
- |
5000 |
|
N/A |
| Clause No - 14(Impulse test voltage) |
- |
5000 |
|
N/A |
| Clause No - 15.1.1(MOISTURE RESISTANCE) |
- |
5000 |
|
N/A |
| Clause No -19.7(test is repeated with the capacitor short circuited) |
- |
0 |
|
N/A |
| Clause No -19.11.4.1(electrostatic discharge) |
- |
0 |
|
N/A |
| Clause No -19.11.4.2(radiated field) |
- |
0 |
|
N/A |
| Clause No -19.11.4.3(fast transient) |
- |
0 |
|
N/A |
| Clause No -19.11.4.4(Voltage dips and interruption) |
- |
0 |
|
N/A |
| Clause No -21.1(Mechanical strength) |
- |
5000 |
|
N/A |
| Clause No -22.1(construction) |
- |
2500 |
|
N/A |
| Clause No -22.11(push force applied) |
- |
2500 |
|
N/A |
| Clause No -24.1.2(safety isolating transformer) |
- |
1000 |
|
N/A |
| Clause No -24.1.3(for switches) |
- |
1000 |
|
N/A |
| Clause No -24.1.4(for automatic control) |
- |
1000 |
|
N/A |
| Clause No -24.1.5(for innterconnection couplers) |
- |
1000 |
|
N/A |
| Clause No -24.4(plug and socket) |
- |
1000 |
|
N/A |
| Clause No -25.8, Table no -11(conductor resistance) |
- |
2500 |
|
N/A |
| Clause No -25.5(dimension for pins) |
- |
2500 |
|
N/A |
| Clause No -27.6(for circuit board) |
- |
5000 |
|
N/A |
| Clause No -29.2(comparative tracking index) |
- |
2500 |
|
N/A |
| Clause No -29.3.3(dry heat test) |
- |
2500 |
|
N/A |
| Clause No -30.2.1(glow wire test) |
- |
3000 |
|
N/A |
| Clause No -30.101("incorporate combustible
material") |
- |
2000 |
|
N/A |
| 15(MOISTURE RESISTANCE) |
- |
5000 |
|
N/A |
| 16(LEAKAGE CURRENT AND ELECTRIC STRENGTH) |
- |
5000 |
|
N/A |
| 17(OVERLOAD PROTECTION OF TRANSFORMERS AND ASSOCIATED CIRCUITS) |
- |
5000 |
|
N/A |
| 18(ENDURANCE) |
- |
0 |
|
N/A |
| 28(SCREWS AND CONNECTIONS) |
- |
5000 |
|
N/A |
| 31(RESISTANCE TO RUSTING) |
- |
5000 |
|
N/A |
| Clause No - 5(GENERAL CONDITIONS FOR THE TESTS) |
- |
3000 |
|
N/A |
| Clause No - 5.18(linear and angular dimension) |
- |
2000 |
|
N/A |
| Clause No - 6.2(harmfull ingress of water) |
- |
5000 |
|
N/A |
|
08 May, 2028 |
- - |
| 7250 |
Amit Test and Calibration Centre (8172006)
| 8172006
| IS 1554 : Part 2 (1988) |
Specification for pvc insulated (Heavy Duty) electric cables: Part 2 for working voltages from 3.3 kV up to and including 11 kV (Second Revision) |
- |
175000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 3.1(CONDUCTOR) |
- |
200 |
|
For BIS Samples – 1.5 times the BIS testing charges. For others : Rs. 1,75,000/- for type test of single core cable. Rs. 2,10,000/- for type test of three core cable Rs. 8500/- for additional test for C1(FR) Rs. 12500/- for additional test for C2(FR-LSH) |
| 3.1.1(CONDUCTOR) |
- |
200 |
|
For BIS Samples – 1.5 times the BIS testing charges. For others : Rs. 1,75,000/- for type test of single core cable. Rs. 2,10,000/- for type test of three core cable Rs. 8500/- for additional test for C1(FR) Rs. 12500/- for additional test for C2(FR-LSH) |
| 4.1(INSULATION) |
- |
200 |
|
For BIS Samples – 1.5 times the BIS testing charges. For others : Rs. 1,75,000/- for type test of single core cable. Rs. 2,10,000/- for type test of three core cable Rs. 8500/- for additional test for C1(FR) Rs. 12500/- for additional test for C2(FR-LSH) |
| 5.1(SCREENING) |
- |
200 |
|
For BIS Samples – 1.5 times the BIS testing charges. For others : Rs. 1,75,000/- for type test of single core cable. Rs. 2,10,000/- for type test of three core cable Rs. 8500/- for additional test for C1(FR) Rs. 12500/- for additional test for C2(FR-LSH) |
| 5.1.1(Non-magnetic Metallic Tape for SingleCore Unscreened and Unarmoured Cables) |
- |
200 |
|
For BIS Samples – 1.5 times the BIS testing charges. For others : Rs. 1,75,000/- for type test of single core cable. Rs. 2,10,000/- for type test of three core cable Rs. 8500/- for additional test for C1(FR) Rs. 12500/- for additional test for C2(FR-LSH) |
| 6.1(FILLERS AND INNER SHEATH) |
- |
200 |
|
For BIS Samples – 1.5 times the BIS testing charges. For others : Rs. 1,75,000/- for type test of single core cable. Rs. 2,10,000/- for type test of three core cable Rs. 8500/- for additional test for C1(FR) Rs. 12500/- for additional test for C2(FR-LSH) |
| 6.2(FILLERS AND INNER SHEATH) |
- |
200 |
|
For BIS Samples – 1.5 times the BIS testing charges. For others : Rs. 1,75,000/- for type test of single core cable. Rs. 2,10,000/- for type test of three core cable Rs. 8500/- for additional test for C1(FR) Rs. 12500/- for additional test for C2(FR-LSH) |
| 7.1(ARMOURING) |
- |
200 |
|
For BIS Samples – 1.5 times the BIS testing charges. For others : Rs. 1,75,000/- for type test of single core cable. Rs. 2,10,000/- for type test of three core cable Rs. 8500/- for additional test for C1(FR) Rs. 12500/- for additional test for C2(FR-LSH) |
| 7.2(ARMOURING) |
- |
200 |
|
For BIS Samples – 1.5 times the BIS testing charges. For others : Rs. 1,75,000/- for type test of single core cable. Rs. 2,10,000/- for type test of three core cable Rs. 8500/- for additional test for C1(FR) Rs. 12500/- for additional test for C2(FR-LSH) |
| 8.1(OUTER SHEATH) |
- |
2000 |
|
For BIS Samples – 1.5 times the BIS testing charges. For others : Rs. 1,75,000/- for type test of single core cable. Rs. 2,10,000/- for type test of three core cable Rs. 8500/- for additional test for C1(FR) Rs. 12500/- for additional test for C2(FR-LSH) |
| 9.1(CONDUCTOR) |
- |
200 |
|
For BIS Samples – 1.5 times the BIS testing charges. For others : Rs. 1,75,000/- for type test of single core cable. Rs. 2,10,000/- for type test of three core cable Rs. 8500/- for additional test for C1(FR) Rs. 12500/- for additional test for C2(FR-LSH) |
| 9.2(CONDUCTOR) |
- |
200 |
|
For BIS Samples – 1.5 times the BIS testing charges. For others : Rs. 1,75,000/- for type test of single core cable. Rs. 2,10,000/- for type test of three core cable Rs. 8500/- for additional test for C1(FR) Rs. 12500/- for additional test for C2(FR-LSH) |
| 10.1(CONDUCTOR SCREENING) |
- |
200 |
|
For BIS Samples – 1.5 times the BIS testing charges. For others : Rs. 1,75,000/- for type test of single core cable. Rs. 2,10,000/- for type test of three core cable Rs. 8500/- for additional test for C1(FR) Rs. 12500/- for additional test for C2(FR-LSH) |
| 11.1(INSULATION) |
- |
200 |
|
For BIS Samples – 1.5 times the BIS testing charges. For others : Rs. 1,75,000/- for type test of single core cable. Rs. 2,10,000/- for type test of three core cable Rs. 8500/- for additional test for C1(FR) Rs. 12500/- for additional test for C2(FR-LSH) |
| 11.2(INSULATION : Thickness of Insulation) |
- |
1000 |
|
For BIS Samples – 1.5 times the BIS testing charges. For others : Rs. 1,75,000/- for type test of single core cable. Rs. 2,10,000/- for type test of three core cable Rs. 8500/- for additional test for C1(FR) Rs. 12500/- for additional test for C2(FR-LSH) |
| 11.3(INSULATION : Tolerance on Thickness of Insulation) |
- |
1000 |
|
For BIS Samples – 1.5 times the BIS testing charges. For others : Rs. 1,75,000/- for type test of single core cable. Rs. 2,10,000/- for type test of three core cable Rs. 8500/- for additional test for C1(FR) Rs. 12500/- for additional test for C2(FR-LSH) |
| 11.4(INSULATION : Application of Insulation) |
- |
200 |
|
For BIS Samples – 1.5 times the BIS testing charges. For others : Rs. 1,75,000/- for type test of single core cable. Rs. 2,10,000/- for type test of three core cable Rs. 8500/- for additional test for C1(FR) Rs. 12500/- for additional test for C2(FR-LSH) |
| 12.1(INSULATION SCREENING) |
- |
200 |
|
For BIS Samples – 1.5 times the BIS testing charges. For others : Rs. 1,75,000/- for type test of single core cable. Rs. 2,10,000/- for type test of three core cable Rs. 8500/- for additional test for C1(FR) Rs. 12500/- for additional test for C2(FR-LSH) |
| 12.2(INSULATION SCREENING) |
- |
200 |
|
For BIS Samples – 1.5 times the BIS testing charges. For others : Rs. 1,75,000/- for type test of single core cable. Rs. 2,10,000/- for type test of three core cable Rs. 8500/- for additional test for C1(FR) Rs. 12500/- for additional test for C2(FR-LSH) |
| 12.3(INSULATION SCREENING) |
- |
200 |
|
For BIS Samples – 1.5 times the BIS testing charges. For others : Rs. 1,75,000/- for type test of single core cable. Rs. 2,10,000/- for type test of three core cable Rs. 8500/- for additional test for C1(FR) Rs. 12500/- for additional test for C2(FR-LSH) |
| 12.4(INSULATION SCREENING) |
- |
200 |
|
For BIS Samples – 1.5 times the BIS testing charges. For others : Rs. 1,75,000/- for type test of single core cable. Rs. 2,10,000/- for type test of three core cable Rs. 8500/- for additional test for C1(FR) Rs. 12500/- for additional test for C2(FR-LSH) |
| 13.1(CORE IDENTIFICATION) |
- |
200 |
|
For BIS Samples – 1.5 times the BIS testing charges. For others : Rs. 1,75,000/- for type test of single core cable. Rs. 2,10,000/- for type test of three core cable Rs. 8500/- for additional test for C1(FR) Rs. 12500/- for additional test for C2(FR-LSH) |
| 13.1.1(CORE IDENTIFICATION) |
- |
200 |
|
For BIS Samples – 1.5 times the BIS testing charges. For others : Rs. 1,75,000/- for type test of single core cable. Rs. 2,10,000/- for type test of three core cable Rs. 8500/- for additional test for C1(FR) Rs. 12500/- for additional test for C2(FR-LSH) |
| 14.1(LAYING UP OF CORES) |
- |
200 |
|
For BIS Samples – 1.5 times the BIS testing charges. For others : Rs. 1,75,000/- for type test of single core cable. Rs. 2,10,000/- for type test of three core cable Rs. 8500/- for additional test for C1(FR) Rs. 12500/- for additional test for C2(FR-LSH) |
| 15.1(INNER SHEATH (COMMON COVERING)) |
- |
200 |
|
For BIS Samples – 1.5 times the BIS testing charges. For others : Rs. 1,75,000/- for type test of single core cable. Rs. 2,10,000/- for type test of three core cable Rs. 8500/- for additional test for C1(FR) Rs. 12500/- for additional test for C2(FR-LSH) |
| 15.2(INNER SHEATH (COMMON COVERING)) |
- |
200 |
|
For BIS Samples – 1.5 times the BIS testing charges. For others : Rs. 1,75,000/- for type test of single core cable. Rs. 2,10,000/- for type test of three core cable Rs. 8500/- for additional test for C1(FR) Rs. 12500/- for additional test for C2(FR-LSH) |
| 15.3(INNER SHEATH (COMMON COVERING)) |
- |
200 |
|
For BIS Samples – 1.5 times the BIS testing charges. For others : Rs. 1,75,000/- for type test of single core cable. Rs. 2,10,000/- for type test of three core cable Rs. 8500/- for additional test for C1(FR) Rs. 12500/- for additional test for C2(FR-LSH) |
| 15.4(INNER SHEATH (COMMON COVERING) : Thickness of Inner Sheath) |
- |
1000 |
|
For BIS Samples – 1.5 times the BIS testing charges. For others : Rs. 1,75,000/- for type test of single core cable. Rs. 2,10,000/- for type test of three core cable Rs. 8500/- for additional test for C1(FR) Rs. 12500/- for additional test for C2(FR-LSH) |
| 15.4.1(INNER SHEATH (COMMON COVERING) : Thickness of Inner Sheath) |
- |
1000 |
|
For BIS Samples – 1.5 times the BIS testing charges. For others : Rs. 1,75,000/- for type test of single core cable. Rs. 2,10,000/- for type test of three core cable Rs. 8500/- for additional test for C1(FR) Rs. 12500/- for additional test for C2(FR-LSH) |
| 16.1.1(ARMOURING : Application) |
- |
200 |
|
For BIS Samples – 1.5 times the BIS testing charges. For others : Rs. 1,75,000/- for type test of single core cable. Rs. 2,10,000/- for type test of three core cable Rs. 8500/- for additional test for C1(FR) Rs. 12500/- for additional test for C2(FR-LSH) |
| 16.1.2(ARMOURING : Application) |
- |
200 |
|
For BIS Samples – 1.5 times the BIS testing charges. For others : Rs. 1,75,000/- for type test of single core cable. Rs. 2,10,000/- for type test of three core cable Rs. 8500/- for additional test for C1(FR) Rs. 12500/- for additional test for C2(FR-LSH) |
| 16.1.3(ARMOURING : Direction of lay ) |
- |
500 |
|
For BIS Samples – 1.5 times the BIS testing charges. For others : Rs. 1,75,000/- for type test of single core cable. Rs. 2,10,000/- for type test of three core cable Rs. 8500/- for additional test for C1(FR) Rs. 12500/- for additional test for C2(FR-LSH) |
| 16.1.4(ARMOURING : Application) |
- |
200 |
|
For BIS Samples – 1.5 times the BIS testing charges. For others : Rs. 1,75,000/- for type test of single core cable. Rs. 2,10,000/- for type test of three core cable Rs. 8500/- for additional test for C1(FR) Rs. 12500/- for additional test for C2(FR-LSH) |
| 16.2.1(ARMOURING : Type of Armour) |
- |
200 |
|
For BIS Samples – 1.5 times the BIS testing charges. For others : Rs. 1,75,000/- for type test of single core cable. Rs. 2,10,000/- for type test of three core cable Rs. 8500/- for additional test for C1(FR) Rs. 12500/- for additional test for C2(FR-LSH) |
| 16.2.2(ARMOURING : Type of Armour) |
- |
200 |
|
For BIS Samples – 1.5 times the BIS testing charges. For others : Rs. 1,75,000/- for type test of single core cable. Rs. 2,10,000/- for type test of three core cable Rs. 8500/- for additional test for C1(FR) Rs. 12500/- for additional test for C2(FR-LSH) |
| 16.3(Armouring : Dimensions -Wire Diameter) |
- |
1000 |
|
For BIS Samples – 1.5 times the BIS testing charges. For others : Rs. 1,75,000/- for type test of single core cable. Rs. 2,10,000/- for type test of three core cable Rs. 8500/- for additional test for C1(FR) Rs. 12500/- for additional test for C2(FR-LSH) |
| 16.3(Armouring : Dimensions -Formed wire ) |
- |
500 |
|
For BIS Samples – 1.5 times the BIS testing charges. For others : Rs. 1,75,000/- for type test of single core cable. Rs. 2,10,000/- for type test of three core cable Rs. 8500/- for additional test for C1(FR) Rs. 12500/- for additional test for C2(FR-LSH) |
| 16.4(ARMOURING : Joints) |
- |
200 |
|
For BIS Samples – 1.5 times the BIS testing charges. For others : Rs. 1,75,000/- for type test of single core cable. Rs. 2,10,000/- for type test of three core cable Rs. 8500/- for additional test for C1(FR) Rs. 12500/- for additional test for C2(FR-LSH) |
| 16.5(ARMOURING : Resistance) |
- |
1500 |
|
For BIS Samples – 1.5 times the BIS testing charges. For others : Rs. 1,75,000/- for type test of single core cable. Rs. 2,10,000/- for type test of three core cable Rs. 8500/- for additional test for C1(FR) Rs. 12500/- for additional test for C2(FR-LSH) |
| 13.6 a)(ARMOURING: Tensile Strength) |
- |
1500 |
|
For BIS Samples – 1.5 times the BIS testing charges. For others : Rs. 1,75,000/- for type test of single core cable. Rs. 2,10,000/- for type test of three core cable Rs. 8500/- for additional test for C1(FR) Rs. 12500/- for additional test for C2(FR-LSH) |
| 13.6 b)(ARMOURING: Elongation ) |
- |
1500 |
|
For BIS Samples – 1.5 times the BIS testing charges. For others : Rs. 1,75,000/- for type test of single core cable. Rs. 2,10,000/- for type test of three core cable Rs. 8500/- for additional test for C1(FR) Rs. 12500/- for additional test for C2(FR-LSH) |
| 13.6 c)(ARMOURING: Torsion Test (For round wire ) ) |
- |
1500 |
|
For BIS Samples – 1.5 times the BIS testing charges. For others : Rs. 1,75,000/- for type test of single core cable. Rs. 2,10,000/- for type test of three core cable Rs. 8500/- for additional test for C1(FR) Rs. 12500/- for additional test for C2(FR-LSH) |
| 13.6 d)(ARMOURING: Winding Test(For formed wire)) |
- |
1500 |
|
For BIS Samples – 1.5 times the BIS testing charges. For others : Rs. 1,75,000/- for type test of single core cable. Rs. 2,10,000/- for type test of three core cable Rs. 8500/- for additional test for C1(FR) Rs. 12500/- for additional test for C2(FR-LSH) |
| 13.6 e)(ARMOURING: Uniformity of zinc coating) |
- |
1500 |
|
For BIS Samples – 1.5 times the BIS testing charges. For others : Rs. 1,75,000/- for type test of single core cable. Rs. 2,10,000/- for type test of three core cable Rs. 8500/- for additional test for C1(FR) Rs. 12500/- for additional test for C2(FR-LSH) |
| 13.6 f)(ARMOURING: Mass of zinc coating ) |
- |
1000 |
|
For BIS Samples – 1.5 times the BIS testing charges. For others : Rs. 1,75,000/- for type test of single core cable. Rs. 2,10,000/- for type test of three core cable Rs. 8500/- for additional test for C1(FR) Rs. 12500/- for additional test for C2(FR-LSH) |
| 13.6 g)(ARMOURING: Resistivity) |
- |
2000 |
|
For BIS Samples – 1.5 times the BIS testing charges. For others : Rs. 1,75,000/- for type test of single core cable. Rs. 2,10,000/- for type test of three core cable Rs. 8500/- for additional test for C1(FR) Rs. 12500/- for additional test for C2(FR-LSH) |
| 17.1(OUTER SHEATH) |
- |
200 |
|
For BIS Samples – 1.5 times the BIS testing charges. For others : Rs. 1,75,000/- for type test of single core cable. Rs. 2,10,000/- for type test of three core cable Rs. 8500/- for additional test for C1(FR) Rs. 12500/- for additional test for C2(FR-LSH) |
| 17.2(OUTER SHEATH : colour ) |
- |
200 |
|
For BIS Samples – 1.5 times the BIS testing charges. For others : Rs. 1,75,000/- for type test of single core cable. Rs. 2,10,000/- for type test of three core cable Rs. 8500/- for additional test for C1(FR) Rs. 12500/- for additional test for C2(FR-LSH) |
| 17.3.1(Thickness of Outer Sheath : Unarmoured Cables) |
- |
1000 |
|
For BIS Samples – 1.5 times the BIS testing charges. For others : Rs. 1,75,000/- for type test of single core cable. Rs. 2,10,000/- for type test of three core cable Rs. 8500/- for additional test for C1(FR) Rs. 12500/- for additional test for C2(FR-LSH) |
| 17.3.2(Thickness of Outer Sheath : Armoured Cables) |
- |
1000 |
|
For BIS Samples – 1.5 times the BIS testing charges. For others : Rs. 1,75,000/- for type test of single core cable. Rs. 2,10,000/- for type test of three core cable Rs. 8500/- for additional test for C1(FR) Rs. 12500/- for additional test for C2(FR-LSH) |
| 18.1 a) 1)(Tests on Conductor : Annealing test (for copper)) |
- |
1000 |
|
For BIS Samples – 1.5 times the BIS testing charges. For others : Rs. 1,75,000/- for type test of single core cable. Rs. 2,10,000/- for type test of three core cable Rs. 8500/- for additional test for C1(FR) Rs. 12500/- for additional test for C2(FR-LSH) |
| 18.1 a) 2)(Tensile test (for aluminium) - Before stranding ) |
- |
1000 |
|
For BIS Samples – 1.5 times the BIS testing charges. For others : Rs. 1,75,000/- for type test of single core cable. Rs. 2,10,000/- for type test of three core cable Rs. 8500/- for additional test for C1(FR) Rs. 12500/- for additional test for C2(FR-LSH) |
| 18.1 a) 2)(Tensile test (for aluminium) - After stranding ) |
- |
1000 |
|
For BIS Samples – 1.5 times the BIS testing charges. For others : Rs. 1,75,000/- for type test of single core cable. Rs. 2,10,000/- for type test of three core cable Rs. 8500/- for additional test for C1(FR) Rs. 12500/- for additional test for C2(FR-LSH) |
| 18.1 a) 3)(Tests on Conductor : Wrapping test ( for aluminium)) |
- |
1000 |
|
For BIS Samples – 1.5 times the BIS testing charges. For others : Rs. 1,75,000/- for type test of single core cable. Rs. 2,10,000/- for type test of three core cable Rs. 8500/- for additional test for C1(FR) Rs. 12500/- for additional test for C2(FR-LSH) |
| 18.1 a)4)(Tests on conductor : Conductor resistance test - Main conductor ) |
- |
5000 |
|
For BIS Samples – 1.5 times the BIS testing charges. For others : Rs. 1,75,000/- for type test of single core cable. Rs. 2,10,000/- for type test of three core cable Rs. 8500/- for additional test for C1(FR) Rs. 12500/- for additional test for C2(FR-LSH) |
| 18.1 a)4)(Resistance test - Neutral conductor ) |
- |
5000 |
|
For BIS Samples – 1.5 times the BIS testing charges. For others : Rs. 1,75,000/- for type test of single core cable. Rs. 2,10,000/- for type test of three core cable Rs. 8500/- for additional test for C1(FR) Rs. 12500/- for additional test for C2(FR-LSH) |
| 18.1 d) 1)(Phyaical tests for insulation : Tensile Test) |
- |
2000 |
|
For BIS Samples – 1.5 times the BIS testing charges. For others : Rs. 1,75,000/- for type test of single core cable. Rs. 2,10,000/- for type test of three core cable Rs. 8500/- for additional test for C1(FR) Rs. 12500/- for additional test for C2(FR-LSH) |
| 18.1 d) 1)(Phyaical tests for insulation : Elongation ) |
- |
2000 |
|
For BIS Samples – 1.5 times the BIS testing charges. For others : Rs. 1,75,000/- for type test of single core cable. Rs. 2,10,000/- for type test of three core cable Rs. 8500/- for additional test for C1(FR) Rs. 12500/- for additional test for C2(FR-LSH) |
| 18.1 d) 1)(Physical tests for sheath : Tensile stregth ) |
- |
2000 |
|
For BIS Samples – 1.5 times the BIS testing charges. For others : Rs. 1,75,000/- for type test of single core cable. Rs. 2,10,000/- for type test of three core cable Rs. 8500/- for additional test for C1(FR) Rs. 12500/- for additional test for C2(FR-LSH) |
| 18.1 d) 1)(Physical tests for sheath : Elongation ) |
- |
2000 |
|
For BIS Samples – 1.5 times the BIS testing charges. For others : Rs. 1,75,000/- for type test of single core cable. Rs. 2,10,000/- for type test of three core cable Rs. 8500/- for additional test for C1(FR) Rs. 12500/- for additional test for C2(FR-LSH) |
| 18.1 d) 2)(Phyaical tests for insulation- Ageing in air Oven : Tensile Test) |
- |
5000 |
|
For BIS Samples – 1.5 times the BIS testing charges. For others : Rs. 1,75,000/- for type test of single core cable. Rs. 2,10,000/- for type test of three core cable Rs. 8500/- for additional test for C1(FR) Rs. 12500/- for additional test for C2(FR-LSH) |
| 18.1 d) 2)(Phyaical tests for insulation - Ageing in air oven : Elongation ) |
- |
5000 |
|
For BIS Samples – 1.5 times the BIS testing charges. For others : Rs. 1,75,000/- for type test of single core cable. Rs. 2,10,000/- for type test of three core cable Rs. 8500/- for additional test for C1(FR) Rs. 12500/- for additional test for C2(FR-LSH) |
| 18.1 d) 2)(Phyaical tests for insulation - Ageing in air Oven : Tensile Variation ) |
- |
5000 |
|
For BIS Samples – 1.5 times the BIS testing charges. For others : Rs. 1,75,000/- for type test of single core cable. Rs. 2,10,000/- for type test of three core cable Rs. 8500/- for additional test for C1(FR) Rs. 12500/- for additional test for C2(FR-LSH) |
| 18.1 d) 2)(Phyaical tests for insulation- Ageing in air oven : Elongation Variation ) |
- |
5000 |
|
For BIS Samples – 1.5 times the BIS testing charges. For others : Rs. 1,75,000/- for type test of single core cable. Rs. 2,10,000/- for type test of three core cable Rs. 8500/- for additional test for C1(FR) Rs. 12500/- for additional test for C2(FR-LSH) |
| 18.1 d) 2)(Physical tests for outer sheath- Ageing in air oven : Tensile stregth ) |
- |
5000 |
|
For BIS Samples – 1.5 times the BIS testing charges. For others : Rs. 1,75,000/- for type test of single core cable. Rs. 2,10,000/- for type test of three core cable Rs. 8500/- for additional test for C1(FR) Rs. 12500/- for additional test for C2(FR-LSH) |
| 18.1 d) 2)(Physical tests for outer sheath -Ageing in air oven : Elongation ) |
- |
5000 |
|
For BIS Samples – 1.5 times the BIS testing charges. For others : Rs. 1,75,000/- for type test of single core cable. Rs. 2,10,000/- for type test of three core cable Rs. 8500/- for additional test for C1(FR) Rs. 12500/- for additional test for C2(FR-LSH) |
| 18.1 d) 2)(Physical tests for outer sheath- Ageing in air oven : Tensile stregth Variation ) |
- |
5000 |
|
For BIS Samples – 1.5 times the BIS testing charges. For others : Rs. 1,75,000/- for type test of single core cable. Rs. 2,10,000/- for type test of three core cable Rs. 8500/- for additional test for C1(FR) Rs. 12500/- for additional test for C2(FR-LSH) |
| 18.1 d) 2)(Physical tests for outer sheath -Ageing in air oven : Elongation Variation ) |
- |
5000 |
|
For BIS Samples – 1.5 times the BIS testing charges. For others : Rs. 1,75,000/- for type test of single core cable. Rs. 2,10,000/- for type test of three core cable Rs. 8500/- for additional test for C1(FR) Rs. 12500/- for additional test for C2(FR-LSH) |
| 18.1 d) 3)(Phyaical tests for insulation : Shrinkage ) |
- |
1500 |
|
For BIS Samples – 1.5 times the BIS testing charges. For others : Rs. 1,75,000/- for type test of single core cable. Rs. 2,10,000/- for type test of three core cable Rs. 8500/- for additional test for C1(FR) Rs. 12500/- for additional test for C2(FR-LSH) |
| 18.1 d) 3)(Phyaical tests for insulation : Shrinkage - Crack observed ) |
- |
1500 |
|
For BIS Samples – 1.5 times the BIS testing charges. For others : Rs. 1,75,000/- for type test of single core cable. Rs. 2,10,000/- for type test of three core cable Rs. 8500/- for additional test for C1(FR) Rs. 12500/- for additional test for C2(FR-LSH) |
| 18.1 d) 3)(Phyaical tests for Sheath : Shrinkage ) |
- |
1500 |
|
For BIS Samples – 1.5 times the BIS testing charges. For others : Rs. 1,75,000/- for type test of single core cable. Rs. 2,10,000/- for type test of three core cable Rs. 8500/- for additional test for C1(FR) Rs. 12500/- for additional test for C2(FR-LSH) |
| 18.1 d) 3)(Phyaical tests for Sheath : Shrinkage - Crack observed ) |
- |
1500 |
|
For BIS Samples – 1.5 times the BIS testing charges. For others : Rs. 1,75,000/- for type test of single core cable. Rs. 2,10,000/- for type test of three core cable Rs. 8500/- for additional test for C1(FR) Rs. 12500/- for additional test for C2(FR-LSH) |
| 18.1 d) 4)(Hot deformation : Insulation ) |
- |
5000 |
|
For BIS Samples – 1.5 times the BIS testing charges. For others : Rs. 1,75,000/- for type test of single core cable. Rs. 2,10,000/- for type test of three core cable Rs. 8500/- for additional test for C1(FR) Rs. 12500/- for additional test for C2(FR-LSH) |
| 18.1 d) 4)(Hot deformation : Sheath ) |
- |
5000 |
|
For BIS Samples – 1.5 times the BIS testing charges. For others : Rs. 1,75,000/- for type test of single core cable. Rs. 2,10,000/- for type test of three core cable Rs. 8500/- for additional test for C1(FR) Rs. 12500/- for additional test for C2(FR-LSH) |
| 18.1 d) 5)( Loss of mass in air oven- Insulation ) |
- |
5000 |
|
For BIS Samples – 1.5 times the BIS testing charges. For others : Rs. 1,75,000/- for type test of single core cable. Rs. 2,10,000/- for type test of three core cable Rs. 8500/- for additional test for C1(FR) Rs. 12500/- for additional test for C2(FR-LSH) |
| 18.1 d) 5)( Loss of mass in air oven- sheath ) |
- |
5000 |
|
For BIS Samples – 1.5 times the BIS testing charges. For others : Rs. 1,75,000/- for type test of single core cable. Rs. 2,10,000/- for type test of three core cable Rs. 8500/- for additional test for C1(FR) Rs. 12500/- for additional test for C2(FR-LSH) |
| 18.1 d) 6)(Heat shock test- Insulation ) |
- |
1500 |
|
For BIS Samples – 1.5 times the BIS testing charges. For others : Rs. 1,75,000/- for type test of single core cable. Rs. 2,10,000/- for type test of three core cable Rs. 8500/- for additional test for C1(FR) Rs. 12500/- for additional test for C2(FR-LSH) |
| 18.1 d) 6)(Heat shock test- sheath ) |
- |
1500 |
|
For BIS Samples – 1.5 times the BIS testing charges. For others : Rs. 1,75,000/- for type test of single core cable. Rs. 2,10,000/- for type test of three core cable Rs. 8500/- for additional test for C1(FR) Rs. 12500/- for additional test for C2(FR-LSH) |
| 18.1 d) 7)(Thermal stability- insulation ) |
- |
2500 |
|
For BIS Samples – 1.5 times the BIS testing charges. For others : Rs. 1,75,000/- for type test of single core cable. Rs. 2,10,000/- for type test of three core cable Rs. 8500/- for additional test for C1(FR) Rs. 12500/- for additional test for C2(FR-LSH) |
| 18.1 d) 7)(Thermal stability- Sheath ) |
- |
2500 |
|
For BIS Samples – 1.5 times the BIS testing charges. For others : Rs. 1,75,000/- for type test of single core cable. Rs. 2,10,000/- for type test of three core cable Rs. 8500/- for additional test for C1(FR) Rs. 12500/- for additional test for C2(FR-LSH) |
| 18.1 d) 8)(Water absorption (gravimetric)(for insulation, where applicable)) |
- |
7000 |
|
For BIS Samples – 1.5 times the BIS testing charges. For others : Rs. 1,75,000/- for type test of single core cable. Rs. 2,10,000/- for type test of three core cable Rs. 8500/- for additional test for C1(FR) Rs. 12500/- for additional test for C2(FR-LSH) |
| 18.1 e)(Insulation resistance test : Volume Resistivity ) |
- |
5000 |
|
For BIS Samples – 1.5 times the BIS testing charges. For others : Rs. 1,75,000/- for type test of single core cable. Rs. 2,10,000/- for type test of three core cable Rs. 8500/- for additional test for C1(FR) Rs. 12500/- for additional test for C2(FR-LSH) |
| 18.1 e)(Insulation resistance test : IR Constant ) |
- |
5000 |
|
For BIS Samples – 1.5 times the BIS testing charges. For others : Rs. 1,75,000/- for type test of single core cable. Rs. 2,10,000/- for type test of three core cable Rs. 8500/- for additional test for C1(FR) Rs. 12500/- for additional test for C2(FR-LSH) |
| 19.2(Partial discharge test) |
- |
45000 |
|
For BIS Samples – 1.5 times the BIS testing charges. For others : Rs. 1,75,000/- for type test of single core cable. Rs. 2,10,000/- for type test of three core cable Rs. 8500/- for additional test for C1(FR) Rs. 12500/- for additional test for C2(FR-LSH) |
| 19.3(Bending test) |
- |
30000 |
|
For BIS Samples – 1.5 times the BIS testing charges. For others : Rs. 1,75,000/- for type test of single core cable. Rs. 2,10,000/- for type test of three core cable Rs. 8500/- for additional test for C1(FR) Rs. 12500/- for additional test for C2(FR-LSH) |
| 19.4(Dielectric power factor test) |
- |
30000 |
|
For BIS Samples – 1.5 times the BIS testing charges. For others : Rs. 1,75,000/- for type test of single core cable. Rs. 2,10,000/- for type test of three core cable Rs. 8500/- for additional test for C1(FR) Rs. 12500/- for additional test for C2(FR-LSH) |
| 19.4(Dielectric power factor test) |
- |
30000 |
|
For BIS Samples – 1.5 times the BIS testing charges. For others : Rs. 1,75,000/- for type test of single core cable. Rs. 2,10,000/- for type test of three core cable Rs. 8500/- for additional test for C1(FR) Rs. 12500/- for additional test for C2(FR-LSH) |
| 19.5(Heating cycle test) |
- |
25000 |
|
For BIS Samples – 1.5 times the BIS testing charges. For others : Rs. 1,75,000/- for type test of single core cable. Rs. 2,10,000/- for type test of three core cable Rs. 8500/- for additional test for C1(FR) Rs. 12500/- for additional test for C2(FR-LSH) |
| 19.6(Impulse withstand test) |
- |
30000 |
|
For BIS Samples – 1.5 times the BIS testing charges. For others : Rs. 1,75,000/- for type test of single core cable. Rs. 2,10,000/- for type test of three core cable Rs. 8500/- for additional test for C1(FR) Rs. 12500/- for additional test for C2(FR-LSH) |
| 19.7(High voltage test) |
- |
10000 |
|
For BIS Samples – 1.5 times the BIS testing charges. For others : Rs. 1,75,000/- for type test of single core cable. Rs. 2,10,000/- for type test of three core cable Rs. 8500/- for additional test for C1(FR) Rs. 12500/- for additional test for C2(FR-LSH) |
| 19.8(Flammability test) |
- |
2500 |
|
For BIS Samples – 1.5 times the BIS testing charges. For others : Rs. 1,75,000/- for type test of single core cable. Rs. 2,10,000/- for type test of three core cable Rs. 8500/- for additional test for C1(FR) Rs. 12500/- for additional test for C2(FR-LSH) |
| 19.9(Oxygen Index Test) |
- |
5000 |
|
For BIS Samples – 1.5 times the BIS testing charges. For others : Rs. 1,75,000/- for type test of single core cable. Rs. 2,10,000/- for type test of three core cable Rs. 8500/- for additional test for C1(FR) Rs. 12500/- for additional test for C2(FR-LSH) |
| 19.10(Flame Retardance Test on Single Cables) |
- |
5000 |
|
For BIS Samples – 1.5 times the BIS testing charges. For others : Rs. 1,75,000/- for type test of single core cable. Rs. 2,10,000/- for type test of three core cable Rs. 8500/- for additional test for C1(FR) Rs. 12500/- for additional test for C2(FR-LSH) |
| 19.11(Flame Retardance Test on Bunched Cables) |
- |
5000 |
|
For BIS Samples – 1.5 times the BIS testing charges. For others : Rs. 1,75,000/- for type test of single core cable. Rs. 2,10,000/- for type test of three core cable Rs. 8500/- for additional test for C1(FR) Rs. 12500/- for additional test for C2(FR-LSH) |
| 19.13(Test for Halogen Acid Gas Evolution) |
- |
5000 |
|
For BIS Samples – 1.5 times the BIS testing charges. For others : Rs. 1,75,000/- for type test of single core cable. Rs. 2,10,000/- for type test of three core cable Rs. 8500/- for additional test for C1(FR) Rs. 12500/- for additional test for C2(FR-LSH) |
| 19.14(Temperature Index) |
- |
5000 |
|
For BIS Samples – 1.5 times the BIS testing charges. For others : Rs. 1,75,000/- for type test of single core cable. Rs. 2,10,000/- for type test of three core cable Rs. 8500/- for additional test for C1(FR) Rs. 12500/- for additional test for C2(FR-LSH) |
| 18.4(Optional Test : Cold Impact ) |
- |
2500 |
|
For BIS Samples – 1.5 times the BIS testing charges. For others : Rs. 1,75,000/- for type test of single core cable. Rs. 2,10,000/- for type test of three core cable Rs. 8500/- for additional test for C1(FR) Rs. 12500/- for additional test for C2(FR-LSH) |
| 20.1(IDENTIFICATION : Manufacturer's Identification) |
- |
200 |
|
For BIS Samples – 1.5 times the BIS testing charges. For others : Rs. 1,75,000/- for type test of single core cable. Rs. 2,10,000/- for type test of three core cable Rs. 8500/- for additional test for C1(FR) Rs. 12500/- for additional test for C2(FR-LSH) |
| 20.2(IDENTIFICATION : Cable Identification) |
- |
200 |
|
For BIS Samples – 1.5 times the BIS testing charges. For others : Rs. 1,75,000/- for type test of single core cable. Rs. 2,10,000/- for type test of three core cable Rs. 8500/- for additional test for C1(FR) Rs. 12500/- for additional test for C2(FR-LSH) |
| 20.3(IDENTIFICATION : Cable Code) |
- |
200 |
|
For BIS Samples – 1.5 times the BIS testing charges. For others : Rs. 1,75,000/- for type test of single core cable. Rs. 2,10,000/- for type test of three core cable Rs. 8500/- for additional test for C1(FR) Rs. 12500/- for additional test for C2(FR-LSH) |
| Cl. 18.1 d) 8)(Water absorption Test (Gravimetric)) |
- |
7000 |
|
For BIS Samples – 1.5 times the BIS testing charges. For others : Rs. 1,75,000/- for type test of single core cable. Rs. 2,10,000/- for type test of three core cable Rs. 8500/- for additional test for C1(FR) Rs. 12500/- for additional test for C2(FR-LSH) |
| Cl.20.1(Manufacturer's Identification) |
- |
200 |
|
For BIS Samples – 1.5 times the BIS testing charges. For others : Rs. 1,75,000/- for type test of single core cable. Rs. 2,10,000/- for type test of three core cable Rs. 8500/- for additional test for C1(FR) Rs. 12500/- for additional test for C2(FR-LSH) |
| Cl.20.2(Cable Identification) |
- |
200 |
|
For BIS Samples – 1.5 times the BIS testing charges. For others : Rs. 1,75,000/- for type test of single core cable. Rs. 2,10,000/- for type test of three core cable Rs. 8500/- for additional test for C1(FR) Rs. 12500/- for additional test for C2(FR-LSH) |
| Cl.20.3(Cable Code) |
- |
200 |
|
For BIS Samples – 1.5 times the BIS testing charges. For others : Rs. 1,75,000/- for type test of single core cable. Rs. 2,10,000/- for type test of three core cable Rs. 8500/- for additional test for C1(FR) Rs. 12500/- for additional test for C2(FR-LSH) |
| Cl.21.1(Packing & Marking) |
- |
200 |
|
For BIS Samples – 1.5 times the BIS testing charges. For others : Rs. 1,75,000/- for type test of single core cable. Rs. 2,10,000/- for type test of three core cable Rs. 8500/- for additional test for C1(FR) Rs. 12500/- for additional test for C2(FR-LSH) |
| Cl.21.2(Packing & Marking) |
- |
200 |
|
For BIS Samples – 1.5 times the BIS testing charges. For others : Rs. 1,75,000/- for type test of single core cable. Rs. 2,10,000/- for type test of three core cable Rs. 8500/- for additional test for C1(FR) Rs. 12500/- for additional test for C2(FR-LSH) |
| Cl.21.2.1(Packing & Marking) |
- |
200 |
|
For BIS Samples – 1.5 times the BIS testing charges. For others : Rs. 1,75,000/- for type test of single core cable. Rs. 2,10,000/- for type test of three core cable Rs. 8500/- for additional test for C1(FR) Rs. 12500/- for additional test for C2(FR-LSH) |
|
16 Apr, 2029 |
- Included w.e.f.05.03.2025 |
| 7251 |
Planet Electro Labs Private Limited, Wazirpur
| 8185226
| IS 302 : Part 2 : Sec 23 (2009) |
Safety of household and similar electrical appliances: Part 2 particular requirements: Sec 23 appliances for skin or hair care (First Revision) |
- |
48000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 7(Marking/ Marking & Instructions) |
- |
1000 |
|
N/A |
| 8(Protection against Electric Shock/ Protection against Access to Live Parts) |
- |
1000 |
|
N/A |
| 9(Starting Of Motor Operated Appliances) |
- |
1000 |
|
N/A |
| 10(Power Input
& Current) |
- |
2000 |
|
N/A |
| 11(Temperature Rise/Heating) |
- |
2000 |
|
N/A |
| 13(Leakage Current and Electric Strength at Operating Temperature) |
- |
1000 |
|
N/A |
| 14(Transient Over Voltage) |
- |
1000 |
|
N/A |
| 15(Moisture Resistance) |
- |
2000 |
|
N/A |
| 16(Leakage Current and Electric Strength) |
- |
1000 |
|
N/A |
| 17(Overload Protection/ Overload Protection of Transformers & Associated Circuits) |
- |
1000 |
|
N/A |
| 18(Endurance) |
- |
2000 |
|
N/A |
| 19(Abnormal Operation) |
- |
1000 |
|
N/A |
| 20(Stability & Mechanical Hazards) |
- |
3000 |
|
N/A |
| 21(Mechanical strength) |
- |
3000 |
|
N/A |
| 22(Construction) |
- |
2000 |
|
N/A |
| 23(Internal wiring) |
- |
2000 |
|
N/A |
| 24(Component) |
- |
2000 |
|
N/A |
| 25(Supply Connection & External Flexible Cables and Cords) |
- |
2000 |
|
N/A |
| 26(Terminals For External Conductors) |
- |
2000 |
|
N/A |
| 27(Provision For Earthing) |
- |
2000 |
|
N/A |
| 28(Screws & Connection) |
- |
1000 |
|
N/A |
| 29(Clearances, Creepage Distances & Solid Insulation) |
- |
1000 |
|
N/A |
| 30(Resistance to Heat & Fire) |
- |
2000 |
|
N/A |
| 31(Resistance to Rusting) |
- |
2000 |
|
N/A |
| 32(Radiation ,Toxicity and similar hazards) |
- |
2000 |
|
N/A |
| 6(Classification) |
- |
1000 |
|
N/A |
| 22.32(CONSTRUCTION) |
- |
1000 |
|
N/A |
| 19.11.4.1(Electrostatic discharges) |
- |
0 |
|
N/A |
| 19.11.4.2(Radiated fields) |
- |
0 |
|
N/A |
| 19.11.4.3(Fast transient bursts) |
- |
0 |
|
N/A |
| 19.11.4.4(Surge immunity test) |
- |
0 |
|
N/A |
| 19.11.4.5(Immunity to conducted discharges) |
- |
0 |
|
N/A |
| 19.11.4.6(Class 3 Voltage dips and interruptions) |
- |
0 |
|
N/A |
| 19.11.4.7(Harmonics) |
- |
0 |
|
N/A |
|
08 May, 2028 |
- 19.11.4.1 TO 19.11.4.7 |
| 7252 |
Conformity Testing Labs Pvt. Ltd. Unit 2 (A33)
| 8139626
| IS 18476 (2023) |
Fasteners � Hexagon Washer Head Drilling Screws with Tapping Screw Thread |
- |
20000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Clause. 4.0(Dimenssions.) |
- |
3000 |
|
- |
| Clause. 4.0(Thread size.) |
- |
3000 |
|
- |
| Clause. 4.0(Length) |
- |
3000 |
|
- |
| Clause. 5.0(Material) |
- |
3000 |
|
- |
| Clause. 5.0(Thread) |
- |
3000 |
|
- |
| Clause. 5.0(Tolerances) |
- |
3000 |
|
- |
| Clause. 5.0(Mechnical and functional properties.) |
- |
5000 |
|
- |
| Clause. 5.0(Finish) |
- |
3000 |
|
- |
| Clause. 5.0(Acceptability) |
- |
3000 |
|
- |
| Clause.6.0(Designation) |
- |
3000 |
|
- |
| Clause.6.0(Marking) |
- |
3000 |
|
- |
|
05 Apr, 2027 |
- Included w.e.f. 03.03.2025 |
| 7253 |
Planet Electro Labs Private Limited, Wazirpur
| 8185226
| IS 302 : Part 2 : Sec 6 (2009) |
Safety of household and similar electrical appliances: Part 2 particular requirements: Sec 6 cooking ranges, hobs, ovens and similar appliances (First Revision) |
- |
39000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 6.0(Classification) |
- |
1000 |
|
N/A |
| 7.0(Marking and instructions) |
- |
2000 |
|
N/A |
| 8.0(Protection against access to live part test) |
- |
2000 |
|
N/A |
| 9.0(Starting of motor-operated appliances test) |
- |
1000 |
|
N/A |
| 10.0(Power Input and current test) |
- |
2000 |
|
N/A |
| 11.0(Heating test) |
- |
2000 |
|
N/A |
| 13.0(Leakage current and electric strength test) |
- |
1000 |
|
N/A |
| 14.0(Transient voltages) |
- |
1000 |
|
N/A |
| 16.0(Leakage current and electric strength test) |
- |
1000 |
|
N/A |
| 15.0(Moisture Resistance) |
- |
2000 |
|
N/A |
| 17.0(Overload protection of transformers test) |
- |
1000 |
|
N/A |
| 19.0(Abnormal Operations) |
- |
2000 |
|
N/A |
| 20.0(Stability and Mechanical Hazards) |
- |
2000 |
|
N/A |
| 21.0(Mechanical Strength) |
- |
2000 |
|
N/A |
| 22.0(Construction verification related tests) |
- |
2000 |
|
N/A |
| 23.0(Internal wiring) |
- |
1000 |
|
N/A |
| 24.0(Components) |
- |
1000 |
|
N/A |
| 25.0(Supply connections and External Flexible Cords) |
- |
1000 |
|
N/A |
| 26.0(Terminal for External Conductors) |
- |
1000 |
|
N/A |
| 27.0(Provision for Earthing) |
- |
2000 |
|
N/A |
| 28.0(Screws and connections) |
- |
1000 |
|
N/A |
| 29.0(Clearances and Creepage distances and solid insulation) |
- |
1000 |
|
N/A |
| 30.0(Resistance to heat and fire) |
- |
2000 |
|
N/A |
| 31.0(Resistance to rusting) |
- |
2000 |
|
N/A |
| 18.0(Endurance test) |
- |
1000 |
|
N/A |
| 32.0(Radiation, Toxicity and Similar hazards) |
- |
1000 |
|
N/A |
| 19.11.4.1(Electrostatic discharges) |
- |
0 |
|
N/A |
| 19.11.4.2(Radiated fields) |
- |
0 |
|
N/A |
| 19.11.4.3(Fast transient bursts) |
- |
0 |
|
N/A |
| 19.11.4.4(Surge immunity test) |
- |
0 |
|
N/A |
| 19.11.4.5(Immunity to conducted discharges) |
- |
0 |
|
N/A |
| 19.11.4.6(Class 3 Voltage dips and interruptions) |
- |
0 |
|
N/A |
| 19.11.4.7(Harmonics) |
- |
0 |
|
N/A |
| 4(General Requirements) |
- |
1000 |
|
N/A |
| 5(General condition for the tests) |
- |
1000 |
|
N/A |
|
08 May, 2028 |
- 19.11.4.1 TO 19.11.4.7 |
| 7254 |
Gravitas Laboratories Private Limited, Greater Noida
| 8182606
| IS 15961 (2012) |
Hot dip aluminium - Zinc alloy metallic coated steel strip and sheet (Plain) |
All Size |
7000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl 8(UTM) |
- |
5000 |
|
- |
| Cl 9 & Table 2(Workmanship) |
- |
5000 |
|
- |
| Cl 10(Coating Adhesion ) |
- |
5000 |
|
- |
| Cl 11(Workmanship) |
- |
5000 |
|
- |
| Cl 12(Weight) |
- |
5000 |
|
- |
| Cl 13(Length, Width, Thickness, Camber, Deviation From Squareness & Deviation From Flatness) |
- |
5000 |
|
- |
| Cl 8(UTM) |
- |
5000 |
|
- |
| Cl 9 & Table 2(Workmanship) |
- |
5000 |
|
- |
| Cl 10(Coating Adhesion ) |
- |
5000 |
|
- |
| Cl 11(Workmanship) |
- |
5000 |
|
- |
| Cl 12(Weight) |
- |
5000 |
|
- |
| Cl 13(Length, Width, Thickness, Camber, Deviation From Squareness & Deviation From Flatness) |
- |
5000 |
|
- |
| Cl 8(UTM) |
- |
5000 |
|
- |
| Cl 9 & Table 2(Workmanship) |
- |
5000 |
|
- |
| Cl 10(Coating Adhesion ) |
- |
5000 |
|
- |
| Cl 11(Workmanship) |
- |
5000 |
|
- |
| Cl 12(Weight) |
- |
5000 |
|
- |
| Cl 13(Length, Width, Thickness, Camber, Deviation From Squareness & Deviation From Flatness) |
- |
5000 |
|
- |
| Cl. 13.7(Deviation from Flatness (Steepness)) |
- |
5000 |
|
- |
| Cl. 13.6(Deviation from Squareness (Out of Square)) |
- |
5000 |
|
- |
| Cl. 13.5(Camber) |
- |
5000 |
|
- |
| Cl. 13.4(Thickness) |
- |
5000 |
|
- |
| Cl. 13.3(Width) |
- |
5000 |
|
- |
| 4, 5(CARBON) |
- |
5000 |
|
- |
| 4, 5(SULPHUR) |
- |
5000 |
|
- |
| 4, 5(PHOSPHURS) |
- |
5000 |
|
- |
| 4.5(MANGANESE) |
- |
5000 |
|
- |
| 4, 5(NITROGEN) |
- |
5000 |
|
- |
| 4, 5(SILICON) |
- |
5000 |
|
- |
| 4, 5(ALUMINIUM) |
- |
5000 |
|
- |
| Cl 13(Length, Width, Thickness, Camber, Deviation From Squareness & Deviation From Flatness) |
- |
5000 |
|
- |
| Cl 12(Weight) |
- |
5000 |
|
- |
| Cl 11(Workmanship) |
- |
5000 |
|
- |
| Cl 10(Coating Adhesion ) |
- |
5000 |
|
- |
| Cl 9 & Table 2(Workmanship) |
- |
5000 |
|
- |
| Cl 8(UTM) |
- |
5000 |
|
- |
| Cl 8(UTM) |
- |
5000 |
|
- |
| Cl 9 & Table 2(Workmanship) |
- |
5000 |
|
- |
| Cl 10(Coating Adhesion) |
- |
5000 |
|
- |
| Cl 11(Workmanship) |
- |
5000 |
|
- |
| Cl 12(Weight) |
- |
5000 |
|
- |
| Cl 13(Length, Width, Thickness, Camber, Deviation From Squareness & Deviation From Flatness) |
- |
5000 |
|
- |
| Clause 8, Table 1(IS 1608 Part 1) |
- |
5000 |
|
- |
| Clause 8, Table 1(IS 1608 Part 1) |
- |
5000 |
|
- |
| Clause 8, Table 1(IS 1608 Part 1) |
- |
5000 |
|
- |
| Clause 9(IS 15961) |
- |
5000 |
|
- |
| Clause 9(IS 15961) |
- |
5000 |
|
- |
| Clause 9(IS 15961) |
- |
5000 |
|
- |
| Clause 9.7(IS 15961) |
- |
5000 |
|
- |
| Clause 11(IS 15961) |
- |
5000 |
|
- |
| Clause 12(IS 15961) |
- |
5000 |
|
- |
| Clause 13.1(IS 15961) |
- |
5000 |
|
- |
| Clause 13.2(IS 15961) |
- |
5000 |
|
- |
| Clause 7.1(Any Instrumental Method/Chemical Method) |
- |
5000 |
|
- |
| Clause 7.1(Any Instrumental Method/Chemical Method) |
- |
5000 |
|
- |
| Clause 7.1(Any Instrumental Method/Chemical Method) |
- |
5000 |
|
- |
| Clause 7.1(Any Instrumental Method/Chemical Method) |
- |
500 |
|
- |
| Clause 7.1(Any Instrumental Method/Chemical Method) |
- |
5000 |
|
- |
| Clause 7.1(Any Instrumental Method/Chemical Method) |
- |
5000 |
|
- |
| Clause 7.1(Any Instrumental Method/Chemical Method) |
- |
5000 |
|
- |
| Clause 7.1(Any Instrumental Method/Chemical Method) |
- |
5000 |
|
- |
| Clause 7.1(By Calculation) |
- |
5000 |
|
- |
| 7.1(Chemical composition %, IS 513) |
- |
5000 |
|
- |
| 8.0 (Table No.- 1)(Tensile Test MPa(T.S., Y.S. & El) - IS 1608) |
- |
5000 |
|
- |
| 9.0 (Table No.- 2)(Coating test, g/m2) |
- |
5000 |
|
- |
| 10.0 (Table No.-3)(Coating adhesion test) |
- |
5000 |
|
- |
| 11(Freedom from defects) |
- |
5000 |
|
- |
| 12(Mass, kg) |
- |
5000 |
|
- |
| 13(Dimensions, Shape and Tolerances,mm-IS/ISO 16163) |
- |
5000 |
|
- |
| 7.1(Chemical composition %, IS 513) |
- |
5000 |
|
- |
| 8.0 (Table No.- 1)(Tensile Test MPa(T.S., Y.S. & El) - IS 1608) |
- |
5000 |
|
- |
| 9.0 (Table No.- 2)(Coating test, g/m2) |
- |
5000 |
|
- |
| 10.0 (Table No.-3)(Coating adhesion test) |
- |
5000 |
|
- |
| 11(Freedom from defects) |
- |
5000 |
|
- |
| 12(Mass, kg) |
- |
5000 |
|
- |
| 13(Dimensions, Shape and Tolerances,mm-IS/ISO 16163) |
- |
5000 |
|
- |
| 7.1(Chemical composition %, IS 513) |
- |
5000 |
|
- |
| 8.0 (Table No.- 1)(Tensile Test MPa(T.S., Y.S. & El) - IS 1608) |
- |
5000 |
|
- |
| 9.0 (Table No.- 2)(Coating test, g/m2) |
- |
5000 |
|
- |
| 10.0 (Table No.-3)(Coating adhesion test) |
- |
5000 |
|
- |
| 11(Freedom from defects) |
- |
5000 |
|
- |
| 12(Mass, kg) |
- |
5000 |
|
- |
| 13(Dimensions, Shape and Tolerances,mm-IS/ISO 16163) |
- |
5000 |
|
- |
| Clause 8, Table 1(Tensile Strength) |
- |
5000 |
|
- |
| Clause 8, Table 1(Yield Strength) |
- |
5000 |
|
- |
| Clause 8, Table 1(Elongation) |
- |
5000 |
|
- |
| Clause 9(Coating Test (Triple Spot Test) (Total Both Surface)) |
- |
5000 |
|
- |
| Clause 9(Coating Test (Triple Spot Test) (Total Both Surface)) |
- |
5000 |
|
- |
| Clause 9(Coating Test (Single Spot Test) (Total Both Surface)) |
- |
5000 |
|
- |
| Clause 9(Coating Test (Single Spot Test) (One Surface)) |
- |
5000 |
|
- |
| Clause 9.7(Differential Coating) |
- |
5000 |
|
- |
| Clause 11(Freedom from Defect) |
- |
5000 |
|
- |
| Clause 12(Mass) |
- |
5000 |
|
- |
| Clause 13.1(Coil Internal Diameter) |
- |
5000 |
|
- |
| Clause 13.2(Length Tolerance) |
- |
5000 |
|
- |
| Clause 7.1(Chromium) |
- |
5000 |
|
- |
| Clause 7.1(Nickel) |
- |
5000 |
|
- |
| Clause 7.1(Niobium) |
- |
5000 |
|
- |
| Clause 7.1(Vanadium) |
- |
5000 |
|
- |
| Clause 7.1(Titanium) |
- |
5000 |
|
- |
| Clause 7.1(Molybdenum) |
- |
5000 |
|
- |
| Clause 7.1(Boron) |
- |
5000 |
|
- |
| Clause 7.1(Calcium) |
- |
5000 |
|
- |
| Clause 7.1(Chromium + Nickel + Niobium, Vanadium + Titanium + Molybdenum + Boron + Calcium) |
- |
5000 |
|
- |
| Cl 8(UTM) |
- |
0 |
|
- |
| Cl 9 & Table 2(Workmanship) |
- |
0 |
|
- |
| Cl 10(Coating Adhesion ) |
- |
0 |
|
- |
| Cl 11(Workmanship) |
- |
0 |
|
- |
| Cl 12(Weight) |
- |
0 |
|
- |
| Cl 13(Length, Width, Thickness, Camber, Deviation From Squareness & Deviation From Flatness) |
- |
0 |
|
- |
| Cl 8(UTM) |
- |
0 |
|
- |
| Cl 9 & Table 2(Workmanship) |
- |
0 |
|
- |
| Cl 10(Coating Adhesion ) |
- |
0 |
|
- |
| Cl 11(Workmanship) |
- |
0 |
|
- |
| Cl 12(Weight) |
- |
0 |
|
- |
| Cl 13(Length, Width, Thickness, Camber, Deviation From Squareness & Deviation From Flatness) |
- |
0 |
|
- |
| Cl 8(UTM) |
- |
0 |
|
- |
| Cl 9 & Table 2(Workmanship) |
- |
0 |
|
- |
| Cl 10(Coating Adhesion ) |
- |
0 |
|
- |
| Cl 11(Workmanship) |
- |
0 |
|
- |
| Cl 12(Weight) |
- |
0 |
|
- |
| Cl 13(Length, Width, Thickness, Camber, Deviation From Squareness & Deviation From Flatness) |
- |
0 |
|
- |
| Cl. 13.7(Deviation from Flatness (Steepness)) |
- |
0 |
|
- |
| Cl. 13.6(Deviation from Squareness (Out of Square)) |
- |
0 |
|
- |
| Cl. 13.5(Camber) |
- |
0 |
|
- |
| Cl. 13.4(Thickness) |
- |
0 |
|
- |
| Cl. 13.3(Width) |
- |
0 |
|
- |
| 4, 5(CARBON) |
- |
0 |
|
- |
| 4, 5(SULPHUR) |
- |
0 |
|
- |
| 4, 5(PHOSPHURS) |
- |
0 |
|
- |
| 4.5(MANGANESE) |
- |
0 |
|
- |
| 4, 5(NITROGEN) |
- |
0 |
|
- |
| 4, 5(SILICON) |
- |
0 |
|
- |
| 4, 5(ALUMINIUM) |
- |
0 |
|
- |
| Cl 13(Length, Width, Thickness, Camber, Deviation From Squareness & Deviation From Flatness) |
- |
0 |
|
- |
| Cl 12(Weight) |
- |
0 |
|
- |
| Cl 11(Workmanship) |
- |
0 |
|
- |
| Cl 10(Coating Adhesion ) |
- |
0 |
|
- |
| Cl 9 & Table 2(Workmanship) |
- |
0 |
|
- |
| Cl 8(UTM) |
- |
0 |
|
- |
| Cl 8(UTM) |
- |
0 |
|
- |
| Cl 9 & Table 2(Workmanship) |
- |
0 |
|
- |
| Cl 10(Coating Adhesion) |
- |
0 |
|
- |
| Cl 11(Workmanship) |
- |
0 |
|
- |
| Cl 12(Weight) |
- |
0 |
|
- |
| Cl 13(Length, Width, Thickness, Camber, Deviation From Squareness & Deviation From Flatness) |
- |
0 |
|
- |
| Clause 8, Table 1(IS 1608 Part 1) |
- |
0 |
|
- |
| Clause 8, Table 1(IS 1608 Part 1) |
- |
0 |
|
- |
| Clause 8, Table 1(IS 1608 Part 1) |
- |
0 |
|
- |
| Clause 9(IS 15961) |
- |
0 |
|
- |
| Clause 9(IS 15961) |
- |
0 |
|
- |
| Clause 9(IS 15961) |
- |
0 |
|
- |
| Clause 9.7(IS 15961) |
- |
0 |
|
- |
| Clause 11(IS 15961) |
- |
0 |
|
- |
| Clause 12(IS 15961) |
- |
0 |
|
- |
| Clause 13.1(IS 15961) |
- |
0 |
|
- |
| Clause 13.2(IS 15961) |
- |
0 |
|
- |
| Clause 7.1(Any Instrumental Method/Chemical Method) |
- |
0 |
|
- |
| Clause 7.1(Any Instrumental Method/Chemical Method) |
- |
0 |
|
- |
| Clause 7.1(Any Instrumental Method/Chemical Method) |
- |
0 |
|
- |
| Clause 7.1(Any Instrumental Method/Chemical Method) |
- |
0 |
|
- |
| Clause 7.1(Any Instrumental Method/Chemical Method) |
- |
0 |
|
- |
| Clause 7.1(Any Instrumental Method/Chemical Method) |
- |
0 |
|
- |
| Clause 7.1(Any Instrumental Method/Chemical Method) |
- |
0 |
|
- |
| Clause 7.1(Any Instrumental Method/Chemical Method) |
- |
0 |
|
- |
| Clause 7.1(By Calculation) |
- |
0 |
|
- |
| 7.1(Chemical composition %, IS 513) |
- |
0 |
|
- |
| 8.0 (Table No.- 1)(Tensile Test MPa(T.S., Y.S. & El) - IS 1608) |
- |
0 |
|
- |
| 9.0 (Table No.- 2)(Coating test, g/m2) |
- |
0 |
|
- |
| 10.0 (Table No.-3)(Coating adhesion test) |
- |
0 |
|
- |
| 11(Freedom from defects) |
- |
0 |
|
- |
| 12(Mass, kg) |
- |
0 |
|
- |
| 13(Dimensions, Shape and Tolerances,mm-IS/ISO 16163) |
- |
0 |
|
- |
| 7.1(Chemical composition %, IS 513) |
- |
0 |
|
- |
| 8.0 (Table No.- 1)(Tensile Test MPa(T.S., Y.S. & El) - IS 1608) |
- |
0 |
|
- |
| 9.0 (Table No.- 2)(Coating test, g/m2) |
- |
0 |
|
- |
| 10.0 (Table No.-3)(Coating adhesion test) |
- |
0 |
|
- |
| 11(Freedom from defects) |
- |
0 |
|
- |
| 12(Mass, kg) |
- |
0 |
|
- |
| 13(Dimensions, Shape and Tolerances,mm-IS/ISO 16163) |
- |
0 |
|
- |
| 7.1(Chemical composition %, IS 513) |
- |
0 |
|
- |
| 8.0 (Table No.- 1)(Tensile Test MPa(T.S., Y.S. & El) - IS 1608) |
- |
0 |
|
- |
| 9.0 (Table No.- 2)(Coating test, g/m2) |
- |
0 |
|
- |
| 10.0 (Table No.-3)(Coating adhesion test) |
- |
0 |
|
- |
| 11(Freedom from defects) |
- |
0 |
|
- |
| 12(Mass, kg) |
- |
0 |
|
- |
| 13(Dimensions, Shape and Tolerances,mm-IS/ISO 16163) |
- |
0 |
|
- |
| Clause 8, Table 1(Tensile Strength) |
- |
0 |
|
- |
| Clause 8, Table 1(Yield Strength) |
- |
0 |
|
- |
| Clause 8, Table 1(Elongation) |
- |
0 |
|
- |
| Clause 9(Coating Test (Triple Spot Test) (Total Both Surface)) |
- |
0 |
|
- |
| Clause 9(Coating Test (Triple Spot Test) (Total Both Surface)) |
- |
0 |
|
- |
| Clause 9(Coating Test (Single Spot Test) (Total Both Surface)) |
- |
0 |
|
- |
| Clause 9(Coating Test (Single Spot Test) (One Surface)) |
- |
0 |
|
- |
| Clause 9.7(Differential Coating) |
- |
0 |
|
- |
| Clause 11(Freedom from Defect) |
- |
0 |
|
- |
| Clause 12(Mass) |
- |
0 |
|
- |
| Clause 13.1(Coil Internal Diameter) |
- |
0 |
|
- |
| Clause 13.2(Length Tolerance) |
- |
0 |
|
- |
| Clause 7.1(Chromium) |
- |
0 |
|
- |
| Clause 7.1(Nickel) |
- |
0 |
|
- |
| Clause 7.1(Niobium) |
- |
0 |
|
- |
| Clause 7.1(Vanadium) |
- |
0 |
|
- |
| Clause 7.1(Titanium) |
- |
0 |
|
- |
| Clause 7.1(Molybdenum) |
- |
0 |
|
- |
| Clause 7.1(Boron) |
- |
0 |
|
- |
| Clause 7.1(Calcium) |
- |
0 |
|
- |
| Clause 7.1(Chromium + Nickel + Niobium, Vanadium + Titanium + Molybdenum + Boron + Calcium) |
- |
0 |
|
- |
|
- |
- Included w.e.f 30.05.2025 |
| 7255 |
Planet Electro Labs Private Limited, Wazirpur
| 8185226
| IS 13252 : Part 1 (2010) |
Information technology equipment - Safety: Part 1 general requirements (Second Revision) |
--- |
40000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 1.5(Components) |
- |
1000 |
|
N/A |
| 1.6(Power interface .) |
- |
1000 |
|
N/A |
| 1.7(Markings and instructions) |
- |
2000 |
|
N/A |
| 2.1(Protection from electric shock and energy hazards) |
- |
1000 |
|
N/A |
| 2.2(SELV circuits) |
- |
1000 |
|
N/A |
| 2.3(TNV circuits) |
- |
2000 |
|
N/A |
| 2.4(Limited current circuits) |
- |
1000 |
|
N/A |
| 2.5(Limited power sources .) |
- |
1000 |
|
N/A |
| 2.6(Provisions for earthing and bonding) |
- |
1000 |
|
N/A |
| 2.7(Overcurrent and earth fault protection in primary circuits) |
- |
1000.01 |
|
N/A |
| 2.8(Safety interlocks) |
- |
1000 |
|
N/A |
| 2.9(Electrical insulation) |
- |
5000 |
|
N/A |
| 2.10(Clearances, creepage distances and distances through insulation) |
- |
2000 |
|
N/A |
| 3.1(General) |
- |
1000 |
|
N/A |
| 3.2(Connection to a mains supply) |
- |
1000 |
|
N/A |
| 3.3(Wiring terminals for connection of external conductors) |
- |
1000 |
|
N/A |
| 3.4(Disconnection from the mains supply) |
- |
1000 |
|
N/AA |
| 3.5(Interconnection of equipment) |
- |
1000 |
|
N/A |
| 4.1(Stability) |
- |
1000 |
|
N/A |
| 4.2(Mechanical strength) |
- |
1000 |
|
N/A |
| 4.3(Design and construction) |
- |
1000 |
|
N/A |
| 4.4(Protection against hazardous moving parts) |
- |
1000 |
|
N/A |
| 4.5(Thermal requirements) |
- |
1000 |
|
N/A |
| 4.6(Openings in enclosures) |
- |
1000 |
|
N/A |
| 4.7(Resistance to fire) |
- |
1000 |
|
N/A |
| 5.1(Touch current and protective conductor curren) |
- |
1000 |
|
N/A |
| 5.2(Electric strength) |
- |
1000 |
|
N/A |
| 5.3(Abnormal operating and fault conditions) |
- |
1000 |
|
N/A |
| 6.1(Protection of telecommunication network service persons, and users of other equipment connected to the network, from hazards in the equipment) |
- |
1000 |
|
N/A |
| 6.2(Protection of equipment users from overvoltages on networks telecommunication) |
- |
1000 |
|
N/A |
| 6.3(Protection of the telecommunication wiring system from overheating) |
- |
1000 |
|
N/A |
| 7.1(General) |
- |
500 |
|
N/A |
| 7.2(Protection of cable distribution system service persons, and users of other equipment connected to the system, from hazardous voltages in the equipment) |
- |
500 |
|
N/A |
| 7.3(Protection of equipment users from overvoltages on the cable distribution system) |
- |
500 |
|
N/A |
| 7.4(Insulation between primary circuits and cable distribution systems) |
- |
500 |
|
N/A |
| 2.8.2/2.8.5(Interlock switches) |
- |
1000 |
|
N/A |
| 2.8.7(Switches and Relay) |
- |
0 |
|
N/A |
| 2.10.4.2(Material Group and Comparative Tracking Index) |
- |
1000 |
|
N/A |
| 2.10.5.3(Insulating Compound as Solid Insulation) |
- |
1000 |
|
N/A |
| 2.10.5.6(Thin sheet materials) |
- |
1000 |
|
N/A |
| 2.10.5.11(SMPS Transformer and Inductor) |
- |
0 |
|
N/A |
| 2.10.5.12(Wires in wound components) |
- |
1000 |
|
N/A |
| 2.10.5.13(Winding wire) |
- |
1000 |
|
N/A |
| 2.10.5.14(Additional insulation in wound components) |
- |
1000 |
|
N/A |
| 2.10.6(PCB material) |
- |
1000 |
|
N/A |
| 2.10.8.2(Thermal conditioning (thermal ageing)) |
- |
1000 |
|
N/A |
| 2.10.8.4(Abrasion resistance test) |
- |
1000 |
|
N/A |
| 2.10.9(Thermal Cycling) |
- |
5000 |
|
N/A |
| 2.10.10(Test for Pollution Degree 1 environment and for insulating compound) |
- |
1000 |
|
N/A |
| 2.10.11(Tests for semiconductor devices and for cemented joints) |
- |
1000 |
|
N/A |
| 2.10.12(Enclosed and sealed parts) |
- |
1000 |
|
N/A |
| 3.1.4(Internal wire) |
- |
1000 |
|
N/A |
| 3.2.4(Appliance inlet /connector) |
- |
1000 |
|
N/A |
| 3.2.5(Non re-wirable plug with PVC sheathed cable) |
- |
1000 |
|
N/A |
| 4.2.8(Cathode Ray Tubes) |
- |
0 |
|
N/A |
| 4.3.8(Batteries) |
- |
1000 |
|
N/A |
| 4.3.10(Dust, powders, liquids and gases) |
- |
1000 |
|
N/A |
| 4.3.11(Containers for liquids or gases) |
- |
1000 |
|
N/A |
| 4.3.12(Flammable liquids) |
- |
1000 |
|
N/A |
| 4.3.13.2(Ionizing radiation) |
- |
0 |
|
N/A |
| 4.3.13.3/ Annex Y(Effect of UV radiation on material/Ultraviolet conditioning test) |
- |
1000 |
|
N/A |
| 4.3.13.4(Human exposure to ultraviolet (UV) radiation) |
- |
0 |
|
N/A |
| 4.3.13.5(LED, laser class) |
- |
0 |
|
N/A |
| Annex A3(Hot flaming oil test) |
- |
0 |
|
N/A |
| Annex U(Insulating winding wires for use without interleaved insulation) |
- |
0 |
|
N/A |
| Annex CC(Evaluation of integrated circuit (IC) current limiters) |
- |
0 |
|
N/A |
| Annex K(Thermal Control) |
- |
1000 |
|
N/A |
| Annex Q(Voltage Dependent Resistors) |
- |
1000 |
|
N/A |
| Annex B(Motor tests under abnormal conditions) |
- |
1000 |
|
N/A |
| Annex C(Transformers) |
- |
1000 |
|
N/A |
| Annex DD(Requirements for the mounting means of a rack mounted equipment) |
- |
1000 |
|
N/A |
| Annex EE(Household and home/ office document/ media shredders) |
- |
1000 |
|
N/A |
| 4.6.2(Bottoms of fire enclosures) |
- |
0 |
|
N/A |
| 1.5(Components) |
- |
0 |
|
N/A |
| 2.10.5.4(Opto-coupler) |
- |
0 |
|
N/A |
| 3.2.4(Appliance inlet /connector) |
- |
1000 |
|
N/A |
|
08 May, 2028 |
- - |
| 7256 |
YORLAB LLP
| 7188606
| IS 210 (2009) |
Grey iron castings - Specification (First Revision) |
FG 150/200/220/260/300/350/400 |
5500 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 6(Chemical Composition(chemical
composition shall be as agreed to between the
purchaser and the manufacturer.)) |
- |
1000 |
|
- |
| 7.1(WORKMANSHIP AND FINISH) |
- |
1000 |
|
- |
| 10.1(FREEDOM FROM DEFECTS) |
- |
1500 |
|
- |
| 10.2(FREEDOM FROM DEFECTS) |
- |
500 |
|
- |
| 13(SIZE OF TEST BARS-Diameter) |
- |
250 |
|
- |
| 13(SIZE OF TEST BARS-Length) |
- |
250 |
|
- |
| 15, Table 3(TENSIL.E TEST- IS 1608 Part1 ) |
- |
2000 |
|
- |
| 16, Table 3(Hardness Test) |
- |
1000 |
|
- |
| 17,Annex B(TRANSVERSE TEST) |
- |
2500 |
|
- |
| 18(HYDROSTATIC TEST) |
- |
3000 |
|
- |
| 6(Chemical Composition(chemical
composition shall be as agreed to between the
purchaser and the manufacturer.)) |
- |
1000 |
|
- |
| 7.1(WORKMANSHIP AND FINISH) |
- |
500 |
|
- |
| 10.1(FREEDOM FROM DEFECTS) |
- |
500 |
|
- |
| 10.2(FREEDOM FROM DEFECTS) |
- |
500 |
|
- |
| 13(SIZE OF TEST BARS-Diameter) |
- |
250 |
|
- |
| 13(SIZE OF TEST BARS-Length) |
- |
250 |
|
- |
| 15, Table 3(TENSIL.E TEST- IS 1608 Part1 ) |
- |
2000 |
|
- |
| 16, Table 3(Hardness Test) |
- |
1500 |
|
- |
| 17,Annex B(TRANSVERSE TEST) |
- |
2500 |
|
- |
| 18(HYDROSTATIC TEST) |
- |
3000 |
|
- |
| 9(IS 7754) |
- |
1500 |
|
- |
| 9(IS 7754) |
- |
1500 |
|
- |
| 9(Microstructure) |
- |
1500 |
|
- |
| 21(Marking) |
- |
0 |
|
- |
| 9(Microstructure) |
- |
1500 |
|
- |
| 7.2(Casting dimensions) |
- |
500 |
|
- |
| Cl-6(Phosprorus (P) - IS 12308 ( P-5)) |
- |
500 |
|
- |
|
- |
- - |
| 7257 |
JAWAHARLAL NEHRU ALUMINIUM RESEARCH DEVELOPMENT AND DESIGN CENTER, NAGPUR
| 7184804
| IS 734 (1975) |
Specification for wrought aluminium and aluminium alloy forging stock and forgings (For General Engineering Purposes) (Second Revision) |
- |
2200 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 5.1 table 1(chemical composition) |
- |
1200 |
|
- |
| 5.1 table 2(0.2% proof strength) |
- |
1000 |
|
- |
| 5.1 table 2(Tensile strength) |
- |
1000 |
|
- |
| 5.1 table 2(Elongation) |
- |
1000 |
|
- |
| Cl.5.1(Aluminium - IS 504 and its parts or any other intrumental/chemical methods) |
- |
0 |
|
- |
| Cl.5.1(Copper - IS 504 and its parts or any other intrumental/chemical methods) |
- |
1200 |
|
- |
| Cl.5.1(Magnesium - IS 504 and its parts or any other intrumental/chemical methods) |
- |
1200 |
|
- |
| Cl.5.1(Silicon - IS 504 and its parts or any other intrumental/chemical methods) |
- |
1200 |
|
- |
| Cl.5.1(Iron - IS 504 and its parts or any other intrumental/chemical methods) |
- |
1200 |
|
- |
| Cl.5.1(Manganese - IS 504 and its parts or any other intrumental/chemical methods) |
- |
1200 |
|
- |
| Cl.5.1(Zinc - IS 504 and its parts or any other intrumental/chemical methods) |
- |
1200 |
|
- |
| Cl.5.1(Titanium And/or Other Grain Refining Elements - IS 504 and its parts or any other intrumental/chemical methods) |
- |
1200 |
|
- |
| Cl.5.1(Chromium - IS 504 and its parts or any other intrumental/chemical methods) |
- |
1200 |
|
- |
| Cl.5.1(Remarks (Cu + Mg + Si + Fe + Mn + Zn) - IS 504 and its parts or any other intrumental/chemical methods) |
- |
1200 |
|
- |
| 9.1(Tensile test) |
- |
1000 |
|
- |
|
24 Apr, 2028 |
- - |
| 7258 |
BLUESKY LAB LLP, GHAZIABAD
| 8170306
| IS 302 : Part 2 : Sec 23 (2009) |
Safety of household and similar electrical appliances: Part 2 particular requirements: Sec 23 appliances for skin or hair care (First Revision) |
- |
25000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 31(Resistance to Rusting) |
- |
500 |
|
30% discount offered to BIS |
| 30(Resistance to Heat & Fire) |
- |
1000 |
|
30% discount offered to BIS |
| 29(Clearances, Creepage Distances & Solid Insulation) |
- |
1000 |
|
30% discount offered to BIS |
| 28(Screws & Connection) |
- |
1000 |
|
30% discount offered to BIS |
| 27(Provision For Earthing) |
- |
1000 |
|
30% discount offered to BIS |
| 26(Terminals For External Conductors) |
- |
1000 |
|
30% discount offered to BIS |
| 25(Supply Connection & External Flexible Cables and Cords) |
- |
1000 |
|
30% discount offered to BIS |
| 23(Internal wiring) |
- |
1000 |
|
30% discount offered to BIS |
| 22(Construction) |
- |
1000 |
|
30% discount offered to BIS |
| 21(Mechanical strength) |
- |
1500 |
|
30% discount offered to BIS |
| 20(Stability & Mechanical Hazards) |
- |
1500 |
|
30% discount offered to BIS |
| 19(Abnormal Operation) |
- |
1500 |
|
30% discount offered to BIS |
| 17(Overload Protection/ Overload Protection of Transformers & Associated Circuits) |
- |
1500 |
|
30% discount offered to BIS |
| 16(Leakage Current and Electric Strength) |
- |
1500 |
|
30% discount offered to BIS |
| 15(Moisture Resistance) |
- |
1500 |
|
30% discount offered to BIS |
| 14(Transient Over Voltage) |
- |
1500 |
|
30% discount offered to BIS |
| 13(Leakage Current and Electric Strength at Operating Temperature) |
- |
1500 |
|
30% discount offered to BIS |
| 11(Temperature Rise/Heating) |
- |
1500 |
|
30% discount offered to BIS |
| 10(Power Input
& Current) |
- |
1500 |
|
30% discount offered to BIS |
| 9(Starting Of Motor Operated Appliances) |
- |
1500 |
|
30% discount offered to BIS |
| 8(Protection against Electric Shock/ Protection against Access to Live Parts) |
- |
1500 |
|
30% discount offered to BIS |
| 7(Marking/ Marking & Instructions) |
- |
1000 |
|
30% discount offered to BIS |
| 19.11.4.4(Surge immunity test) |
- |
1500 |
|
30% discount offered to BIS |
| 18(Endurance) |
- |
1500 |
|
30% discount offered to BIS |
| 6(Classification) |
- |
500 |
|
30% discount offered to BIS |
| 22.32(CONSTRUCTION) |
- |
1000 |
|
30% discount offered to BIS |
| 31(Resistance to Rusting) |
- |
- |
|
- |
| 30(Resistance to Heat & Fire) |
- |
- |
|
- |
| 29(Clearances, Creepage Distances & Solid Insulation) |
- |
- |
|
- |
| 28(Screws & Connection) |
- |
- |
|
- |
| 27(Provision For Earthing) |
- |
- |
|
- |
| 26(Terminals For External Conductors) |
- |
- |
|
- |
| 25(Supply Connection & External Flexible Cables and Cords) |
- |
- |
|
- |
| 23(Internal wiring) |
- |
- |
|
- |
| 22(Construction) |
- |
- |
|
- |
| 21(Mechanical strength) |
- |
- |
|
- |
| 20(Stability & Mechanical Hazards) |
- |
- |
|
- |
| 19(Abnormal Operation) |
- |
- |
|
- |
| 17(Overload Protection/ Overload Protection of Transformers & Associated Circuits) |
- |
- |
|
- |
| 16(Leakage Current and Electric Strength) |
- |
- |
|
- |
| 15(Moisture Resistance) |
- |
- |
|
- |
| 14(Transient Over Voltage) |
- |
- |
|
- |
| 13(Leakage Current and Electric Strength at Operating Temperature) |
- |
- |
|
- |
| 11(Temperature Rise/Heating) |
- |
- |
|
- |
| 10(Power Input
& Current) |
- |
- |
|
- |
| 9(Starting Of Motor Operated Appliances) |
- |
- |
|
- |
| 8(Protection against Electric Shock/ Protection against Access to Live Parts) |
- |
- |
|
- |
| 7(Marking/ Marking & Instructions) |
- |
- |
|
- |
| 19.11.4.4(Surge immunity test) |
- |
- |
|
- |
| 18(Endurance) |
- |
- |
|
- |
| 6(Classification) |
- |
- |
|
- |
| 22.32(CONSTRUCTION) |
- |
- |
|
- |
|
22 May, 2028 |
- Included w.e.f.27.02.2025
Exclusion
Cl 19.11.4.1 Electrostatic discharge
Cl 19.11.4.2 (Radiated fields) 24 (Components)
Cl 19.11.4.3 (Fast transient bursts)
Cl 19.11.4.4 (Surge immunity test)
Cl 19.11.4.5 (Immunity to conducted discharges)
Cl 19.11.4.6 (Class 3 Voltage dips and interruptions)
Cl 19.11.4.7 (Harmonics) |
| 7259 |
CIPET, Hyderabad
| 6111634
| IS 14885 (2022) |
Polyethylene Pipes for the Supply of Gaseous Fuels � Specification (First Revision) |
Polyethylene Pipes for the Supply of Gaseous Fuels |
520000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4.2(Grade of material) |
- |
500 |
|
25 % DISCOUNT FOR BIS |
| 4.3(Nominal Diameter) |
- |
500 |
|
25 % DISCOUNT FOR BIS |
| 4.4(Colour) |
- |
500 |
|
25 % DISCOUNT FOR BIS |
| 5.1(Polyethylene
compound) |
- |
6100 |
|
25 % DISCOUNT FOR BIS |
| 5.3(Anti-oxidant) |
- |
0 |
|
25 % DISCOUNT FOR BIS |
| 5.4(U-V stabilizer) |
- |
2500 |
|
25 % DISCOUNT FOR BIS |
| 5.7(PE Compound Quality Evaluation) |
- |
400000 |
|
25 % DISCOUNT FOR BIS |
| 5.5(Effect of Gas
condensate on the
Hydrostatic strength) |
- |
5000 |
|
25 % DISCOUNT FOR BIS |
| 5.6(Resistance to Weathering) |
- |
36000 |
|
25 % DISCOUNT FOR BIS |
| 6.1(Mean out side Diameter (For less than or equal to 25 mm- Average of 8 , For higher diameters average of 6)) |
- |
500 |
|
25 % DISCOUNT FOR BIS |
| 6.1(Out of Roundness (Ovality)) |
- |
500 |
|
25 % DISCOUNT FOR BIS |
| 6.2(Wall thickness (Take 8 reading and Average will be repoted)) |
- |
500 |
|
25 % DISCOUNT FOR BIS |
| 7(Finish) |
- |
500 |
|
25 % DISCOUNT FOR BIS |
| 8.1(Internal pressure creep
rupture test for plain at 80 deg. C for
165h) |
- |
5300 |
|
25 % DISCOUNT FOR BIS |
| 8.1(Internal pressure creep
rupture test for plain
pipes at 20 deg. C for
100h) |
- |
4500 |
|
25 % DISCOUNT FOR BIS |
| 8.1(Internal pressure creep
rupture test for plain
pipes at 80 deg. C for
1000 h) |
- |
11000 |
|
25 % DISCOUNT FOR BIS |
| 8.2(Reversion Test) |
- |
700 |
|
25 % DISCOUNT FOR BIS |
| 8.3(Density) |
- |
700 |
|
25 % DISCOUNT FOR BIS |
| 8.6(Thermal Stability (Oxidation Induction Time)) |
- |
2200 |
|
25 % DISCOUNT FOR BIS |
| 8.7(Volatile Matter Content) |
- |
700 |
|
25 % DISCOUNT FOR BIS |
| 8.8(Tensile Properties (Tensile Yield Strength and
Elongation at Break)) |
- |
1800 |
|
25 % DISCOUNT FOR BIS |
| 8.9(Resistance to Weathering) |
- |
36000 |
|
25 % DISCOUNT FOR BIS |
| 6.4(Length of Pipe) |
- |
500 |
|
25 % DISCOUNT FOR BIS |
| 8.4(Melt Flow Rate (MFR)) |
- |
1100 |
|
25 % DISCOUNT FOR BIS |
| 8.5(Pigment Dispersion) |
- |
700 |
|
25 % DISCOUNT FOR BIS |
| 8.10(Slow Crack Growth Rate Test) |
- |
10800 |
|
25 % DISCOUNT FOR BIS |
| 8.11(Squeeze-off) |
- |
1300 |
|
25 % DISCOUNT FOR BIS |
| 5.1, 5.7 Table 2(i) Conventional density (of base polymer)) |
- |
700 |
|
25 % DISCOUNT FOR BIS |
| 5.1, 5.7 Table 2(ii) Melt flow rate (MFR)) |
- |
1100 |
|
25 % DISCOUNT FOR BIS |
| 5.1, 5.7 Table 2(iii) Thermal stability (oxidation induction time)) |
- |
2200 |
|
25 % DISCOUNT FOR BIS |
| 5.1, 5.7 Table 2(iv) Volatile content) |
- |
700 |
|
25 % DISCOUNT FOR BIS |
| 5.1, 5.7 Table 2(v) Water content1)) |
- |
700 |
|
25 % DISCOUNT FOR BIS |
| 5.1, 5.7 Table 2(vi) Pigment dispersion) |
- |
700 |
|
25 % DISCOUNT FOR BIS |
| 5.1, 5.7 Table 3(iv) Resistance to slow crack growth rate) |
- |
400000 |
|
25 % DISCOUNT FOR BIS |
| 5.3(Anti-Oxidant) |
- |
0 |
|
25 % DISCOUNT FOR BIS |
| 5.4(U.V. Stabilizer) |
- |
2500 |
|
25 % DISCOUNT FOR BIS |
| 5.5(Effects of Gas Condensate on the Hydrostatic Strength) |
- |
5000 |
|
25 % DISCOUNT FOR BIS |
| 5.6(ii) Hydraulic characteristics) |
- |
36000 |
|
25 % DISCOUNT FOR BIS |
| 5.6(iii) Thermal stability (Oxidation induction time)) |
- |
2200 |
|
25 % DISCOUNT FOR BIS |
| 6(Dimensions of pipes) |
- |
1500 |
|
25 % DISCOUNT FOR BIS |
| 7(Finish) |
- |
500 |
|
25 % DISCOUNT FOR BIS |
| 8.1(Hydraulic Characteristics) |
- |
20800 |
|
25 % DISCOUNT FOR BIS |
| 8.2(Reversion test) |
- |
700 |
|
25 % DISCOUNT FOR BIS |
| 8.3(Density) |
- |
700 |
|
25 % DISCOUNT FOR BIS |
| 8.4(Melt Flow Rate) |
- |
1100 |
|
25 % DISCOUNT FOR BIS |
| 8.5(Pigment Dispersion) |
- |
700 |
|
25 % DISCOUNT FOR BIS |
| 8.6(Thermal Stability (Oxidation Induction Time)) |
- |
2200 |
|
25 % DISCOUNT FOR BIS |
| 8.7(Volatile Matter Content) |
- |
700 |
|
25 % DISCOUNT FOR BIS |
| 8.9(Resistance to Weathering) |
- |
36000 |
|
25 % DISCOUNT FOR BIS |
| 8.8(Tensile Properties (Tensile Yield Strength and Elongation at Break)) |
- |
1800 |
|
25 % DISCOUNT FOR BIS |
| 8.10(Slow Crack Growth Rate Test) |
- |
10800 |
|
25 % DISCOUNT FOR BIS |
| 8.11(Squeeze-of) |
- |
1300 |
|
25 % DISCOUNT FOR BIS |
| 10(Marking) |
- |
0 |
|
25 % DISCOUNT FOR BIS |
|
23 Feb, 2027 |
- Included w.e.f.22.05.2025 |
| 7260 |
JAWAHARLAL NEHRU ALUMINIUM RESEARCH DEVELOPMENT AND DESIGN CENTER, NAGPUR
| 7184804
| IS 4026 (2007) |
Aluminium ingots, billets and wire bars (Ec Grade) (Fourth Revision) |
- |
1200 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Clause 8 Table 1(CHEMICAL COMPOSITION
1) Aluminium ,& min) |
- |
1200 |
|
- |
| Clause 8 Table 1(2) Silicon) |
- |
1200 |
|
- |
| Clause 8 Table 1(Chemical Composition
3) Iron) |
- |
1200 |
|
- |
| Clause 8 Table 1(Chemical Composition
4) Copper) |
- |
1200 |
|
- |
| Clause 8 Table 1(Chemical Composition
5) Titanium+ Vanadiun) |
- |
1200 |
|
- |
| Clause 8 Table 1(Chemical Composition
6) Manganese, Zirconium and Chromium) |
- |
1200 |
|
- |
|
24 Apr, 2028 |
- - |