| 7471 |
Ahmedabad Textile Industry's Research Association (ATIRA), Ahmedabad
| 7173002
| IS 17371 (2020) |
Geosynthetics – Geogrids for flexible pavements – Specification |
- |
188350 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 1("Ultimate tensile strength, (MD × CD)- IS 16635
30/30
40/40
50/50
60/60
80/80
100/100") |
- |
1650 |
|
- |
| 1("Tensile strength at 2 percent strain, (MD × CD- IS 16635
20/20
30/30
40/40") |
- |
350 |
|
- |
| 1("Tensile strength at 5 percent strain, (MD × CD- IS 16635
20/20
30/30
40/40") |
- |
350 |
|
- |
| 1(UV resistance, strength retained after 500 h exposure- IS 13162 (part 2)) |
- |
46650 |
|
- |
| 1(Chemical resistance, strength retained after 72 h immersion- IS 17363) |
- |
11940 |
|
- |
| 2("Ultimate tensile strength, (MD × CD)- IS 16635
20/20
30/30
40/40") |
- |
0 |
|
- |
| 2("Tensile strength at 2 percent strain, (MD × CD- IS 16635
20/20
30/30
40/40") |
- |
0 |
|
- |
| 2("Tensile strength at 5 percent strain, (MD × CD- IS 16635
20/20
30/30
40/40") |
- |
0 |
|
- |
| 2(UV resistance, strength retained after 500 h exposure- IS 13162 (part 2)) |
- |
0 |
|
- |
| 2(Chemical resistance, strength retained after 72 h immersion- IS 17363) |
- |
0 |
|
- |
| 2("Junction strength- IS 17371 AnnexB
20/20
30/30
40/40") |
- |
1300 |
|
- |
| Clause No. 4.1(Geogrid Raw Materials) |
- |
82290 |
|
Resistance to Oxidation |
| Clause No. 4.1(Carbon Black content of Geogrid) |
- |
550 |
|
- |
| Clause No. 4.5(Identification of Geogrid) |
- |
700 |
|
Fibre Identification & 1 visual (woven/knitted) |
| Clause No. 5.2, Table No. 1 (ii)(Tensile strength at 2 percent strain, (MD × CD) kN/m of PET Geogrids) |
- |
0 |
|
- |
| Clause No. 5.2, Table No. 1 (iii)(Tensile strength at 5 percent strain, (MD × CD) kN/m of PET Geogrids) |
- |
0 |
|
- |
| Clause No. 5.2, table No. 1 (iv)(UV resistance, strength retained after 500 h exposure of PET Geogrids) |
- |
0 |
|
- |
| Clause No. 5.2, Table No. 1 (v)(Chemical resistance, strength retained after 72 h immersion of PET Geogrids) |
- |
0 |
|
- |
| Clause No. 5.2, table No. 1 (vi)(Width of PET Geogrids) |
- |
300 |
|
- |
| Clause No. 5.2, Table No. 1 (vii)(Roll length of PET Geogrids) |
- |
300 |
|
- |
| Clause No. 5.2, Table No. 2 (i)(Ultimate tensile strength, (MD × CD) kN/m of PP Geogrids) |
- |
0 |
|
- |
| Clause No. 5.2, Table No. 2 (ii)(Tensile strength at 2 percent strain, (MD × CD) kN/m of PP Geogrids) |
- |
0 |
|
- |
| Clause No. 5.2, Table No. 2 (iii)(Tensile strength at 5 percent strain, (MD × CD) kN/m of PP Geogrids) |
- |
0 |
|
- |
| Clause No. 5.2, table No. 2 (iv)(UV resistance, strength retained after 500 h exposure of PP Geogrids) |
- |
0 |
|
- |
| Clause No. 5.2, Table No. 2 (v)(Chemical resistance, strength retained after 72 h immersion of PP Geogrids) |
- |
0 |
|
- |
| Clause No. 5.2, Table No. 2 (vi)(Junction strength, percent strength of original strength) |
- |
0 |
|
- |
| Clause No. 5.2, table No. 2 (vii)(Width of PP Geogrids) |
- |
0 |
|
- |
| Clause No. 5.2, Table No. 2 (viii)(Roll length of PP Geogrids) |
- |
0 |
|
- |
| 4.1(MATERIALS - Geogrid materials shall be inert to all chemicals naturally found in commonly encountered soils not containing adverse solvents and at ambient temperatures) |
- |
41970 |
|
Resistance to hydrolysis |
| 4.2(MATERIALS - Geogrids shall be rendered resistant to UV. Rigid geogrids shall have minimum 2 percent (mass/mass) of carbon black content) |
- |
0 |
|
- |
| 4.5(MATERIALS - Identification of Geogrid) |
- |
0 |
|
- |
| 5.2- Table 1- i)(REQUIREMENTS FOR PET GEOGRIDS - Ultimate tensile strength, (MD × CD) kN/m) |
- |
0 |
|
- |
| 5.2- Table 1- ii)(REQUIREMENTS FOR PET GEOGRIDS - Tensile strength at 2 percent strain, (MD × CD) kN/m,) |
- |
0 |
|
- |
| 5.2- Table 1- iii)(REQUIREMENTS FOR PET GEOGRIDS - Tensile strength at 5 percent strain, (MD × CD) kN/m,) |
- |
0 |
|
- |
| 5.2- Table 1- iv)(REQUIREMENTS FOR PET GEOGRIDS - UV resistance, strength retained after 500 h exposure) |
- |
0 |
|
- |
| 5.2- Table 1- v)(REQUIREMENTS FOR GEOGRIDS - Chemical resistance, strength retained after 72 h immersion) |
- |
0 |
|
- |
| 5.2- Table 1- vi)(REQUIREMENTS FOR PET GEOGRIDS - Width) |
- |
0 |
|
- |
| 5.2- Table 1- vii)(REQUIREMENTS FOR PET GEOGRIDS - Roll length) |
- |
0 |
|
- |
| 5.2- Table 2- i)(REQUIREMENTS FOR PP GEOGRIDS - Ultimate tensile strength, (MD × CD) kN/m) |
- |
0 |
|
- |
| 5.2- Table 2- ii)(REQUIREMENTS FOR PP GEOGRIDS - Tensile strength at 2 percent strain, (MD × CD) kN/m) |
- |
0 |
|
- |
| 5.2- Table 2- iii)(REQUIREMENTS FOR PP GEOGRIDS - Tensile strength at 5 percent strain, (MD × CD) kN/m,) |
- |
0 |
|
- |
| 5.2- Table 2- iv)(REQUIREMENTS FOR PP GEOGRIDS - UV resistance, strength retained after 500 h exposure) |
- |
0 |
|
- |
| 5.2- Table 2- v)(REQUIREMENTS FOR PP GEOGRIDS - Chemical resistance, strength retained after 72 h immersion) |
- |
0 |
|
- |
| 5.2- Table 2- vi)(REQUIREMENTS FOR PP GEOGRIDS - Junction strength, percent strength of original strength) |
- |
0 |
|
- |
| 5.2- Table 2- vii)(REQUIREMENTS FOR PP GEOGRIDS - Width) |
- |
0 |
|
- |
| 5.2- Table 2- vIii)(REQUIREMENTS FOR PET GEOGRIDS - Roll length) |
- |
0 |
|
- |
|
- |
- - |
| 7472 |
Ahmedabad Textile Industry's Research Association (ATIRA), Ahmedabad
| 7173002
| IS 17373 (2020) |
Geosynthetics – Geogrids used in reinforced soil retaining structures – Specification |
- |
186950 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 1("Ultimate tensile strength- (MD/CD)
IS- 16635
60/20
80/30
100/30
120/30
150/30
180/30
200/30
250/30
300/30
350/30
400/30") |
- |
1650 |
|
- |
| 1("Elongation at designated load- IS 16635
MD
CD") |
- |
350 |
|
- |
| 1("UV resistance, strength retained after
500 h exposure- IS 13162 (part-2)") |
- |
46650 |
|
- |
| 1(Chemical resistance, strength retained after 72 h immersion- IS 17363) |
- |
11940 |
|
- |
| 1(Width) |
- |
300 |
|
- |
| 1(Roll Length) |
- |
300 |
|
- |
| 2("Ultimate tensile strength - IS 16635
MD/CD
30/5
40/5
50/5
60/5
70/5
80/5
90/5
100/5
120/5
120/5
150/5
175/5
200/5") |
- |
0 |
|
- |
| 2("Elongation at designated load - IS 16635
MD and CD") |
- |
0 |
|
- |
| 2("UV resistance, strength retained after
500 h exposure- IS 13162 (part-2)") |
- |
0 |
|
- |
| 2(Chemical resistance, strength retained after 72 h immersion- IS 17363) |
- |
0 |
|
- |
| 2(Width) |
- |
0 |
|
- |
| 2(Roll Length) |
- |
0 |
|
- |
| 3("Ultimate tensile strength - IS 16635
MD/CD
50
100
150
200
250
300
350
400
500
600
700
800
900
1000
1100
1200
1300") |
- |
0 |
|
- |
| 3("Elongation at designated load - IS 16635
MD and CD") |
- |
0 |
|
- |
| 3("UV resistance, strength retained after
500 h exposure- IS 13162 (part-2)") |
- |
0 |
|
- |
| 3(Chemical resistance, strength retained after 72 h immersion- IS 17363) |
- |
0 |
|
- |
| 3(Width) |
- |
0 |
|
- |
| 3(Roll Length) |
- |
0 |
|
- |
| CL 3.2(Aperature Size) |
- |
250 |
|
- |
| CL 6.3.3(Resistance to hydrolysis) |
- |
41970 |
|
- |
| CL 6.3.2(Resistance to oxidation) |
- |
82290 |
|
- |
| CL 5.1(Carbon black content) |
- |
550 |
|
- |
| CL 5.1(Identification of material) |
- |
500 |
|
- |
| 4(TYPES OF GEOGRIDS - a) Type 1 b) Type 2 c) Type 3) |
- |
200 |
|
- |
|
- |
- - |
| 7473 |
Gravitas Laboratories Private Limited, Greater Noida
| 8182606
| IS 6911 (2017) |
Stainless steel plate, sheet and strip - Specification (Second Revision) |
- |
15000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl. 7.1 & 7.2 Table 1(Carbon -IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
200 |
|
- |
| Cl. 7.1 & 7.2 Table 1(Silicon -IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
200 |
|
- |
| Cl. 7.1 & 7.2 Table 1(Manganese -IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
200 |
|
- |
| Cl. 7.1 & 7.2 Table 1(Nickel -IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
200 |
|
- |
| Cl. 7.1 & 7.2 Table 1(Chromium -IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
200 |
|
- |
| Cl. 7.1 & 7.2 Table 1(Molybdenum -IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
200 |
|
- |
| Cl. 7.1 & 7.2 Table 1(Sulphur -IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
200 |
|
- |
| Cl. 7.1 & 7.2 Table 1(Phosphorus -IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
200 |
|
- |
| Cl. 7.1 & 7.2 Table 1(Nitrogen -IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
200 |
|
- |
| Cl. 7.1 & 7.2 Table 1(Copper -IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
200 |
|
- |
| Cl. 7.1 & 7.2 Table 1(Others-IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
200 |
|
- |
| Cl. 7.1 & 7.2 Table 1(Titanium-IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
200 |
|
- |
| Cl. 7.1 & 7.2 Table 1(Niobium-IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
200 |
|
- |
| Cl.12(Corrosion Resistance- IS 10461(Part1)) |
- |
2000 |
|
- |
| Cl.12(Corrosion Resistance- IS 10461(Part2)) |
- |
2000 |
|
- |
| 6(Freedom from defects , IS 6911) |
- |
200 |
|
- |
| 10.1,Table 4&Table 6(Tensile Test - IS 1608(Pt -1)) |
- |
500 |
|
- |
| 10.2,Table 4&Table 5(Hardness Test- IS 1500(Pt -1),IS 1501 (Pt-1),IS 1586 (Pt -1)) |
- |
200 |
|
- |
| 10.3(Bend Test - IS 1599) |
- |
200 |
|
- |
| 11,Table 7(Erichsen cupping test-IS 10175) |
- |
200 |
|
- |
| 17(Dimension and tolerance) |
- |
200 |
|
- |
| 10.1 Amd 2(Yeild Strength) |
- |
500 |
|
- |
| 10.1 Amd 2(0.2 Percent Proof Stress) |
- |
500 |
|
- |
| 10.1 Amd 2(Elongation) |
- |
500 |
|
- |
| Clause 17 , Table 9 to Table 19(Dimension (Length)) |
- |
200 |
|
- |
| Clause 17 , Table 9 to Table 19(Dimension (Width)) |
- |
200 |
|
- |
| Clause 17 , Table 9 to Table 19(Dimension (Thickness)) |
- |
200 |
|
- |
| Clause 17 , Table 9 to Table 19(Flatness) |
- |
200 |
|
- |
| Clause 17 , Table 9 to Table 19(Camber) |
- |
200 |
|
- |
| Table 1(Any Instrumental Method/Chemical Method) |
- |
2000 |
|
- |
| Table 1, Amendment 2(Any Instrumental Method/Chemical Method) |
- |
2000 |
|
- |
| Table 1, Amendment 2(Any Instrumental Method/Chemical Method) |
- |
2000 |
|
- |
| Table 1, Amendment 2(Any Instrumental Method/Chemical Method) |
- |
2000 |
|
- |
| Table 1, Amendment 2(Any Instrumental Method/Chemical Method) |
- |
2000 |
|
- |
| Table 1, Amendment 2(Any Instrumental Method/Chemical Method) |
- |
2000 |
|
- |
| 10.1 Amd 2(Yeild Strength) |
- |
500 |
|
- |
| 10.1 Amd 2(0.2 Percent Proof Stress) |
- |
500 |
|
- |
| 10.1 Amd 2(Elongation) |
- |
500 |
|
- |
| Clause 17 , Table 9 to Table 19(Dimension (Length)) |
- |
200 |
|
- |
| Clause 17 , Table 9 to Table 19(Dimension (Width)) |
- |
200 |
|
- |
| Clause 17 , Table 9 to Table 19(Dimension (Thickness)) |
- |
200 |
|
- |
| Clause 17 , Table 9 to Table 19(Flatness) |
- |
200 |
|
- |
| Clause 17 , Table 9 to Table 19(Camber) |
- |
200 |
|
- |
| Table 1(Any Instrumental Method/Chemical Method) |
- |
2000 |
|
- |
| Table 1, Amendment 2(Any Instrumental Method/Chemical Method) |
- |
2000 |
|
- |
| Table 1, Amendment 2(Any Instrumental Method/Chemical Method) |
- |
2000 |
|
- |
| Table 1, Amendment 2(Any Instrumental Method/Chemical Method) |
- |
2000 |
|
- |
| Table 1, Amendment 2(Any Instrumental Method/Chemical Method) |
- |
2000 |
|
- |
| Table 1, Amendment 2(Any Instrumental Method/Chemical Method) |
- |
2000 |
|
- |
| 10.1 Amd 2(Yeild Strength) |
- |
500 |
|
- |
| 10.1 Amd 2(0.2 Percent Proof Stress) |
- |
500 |
|
- |
| 10.1 Amd 2(Elongation) |
- |
500 |
|
- |
| Clause 17 , Table 9 to Table 19(Dimension (Length)) |
- |
200 |
|
- |
| Clause 17 , Table 9 to Table 19(Dimension (Width)) |
- |
200 |
|
- |
| 10.1 Amd 2(Yeild Strength) |
- |
500 |
|
- |
| 10.1 Amd 2(0.2 Percent Proof Stress) |
- |
500 |
|
- |
| 10.1 Amd 2(Yeild Strength) |
- |
500 |
|
- |
| 10.1 Amd 2(0.2 Percent Proof Stress) |
- |
500 |
|
- |
| 10.1 Amd 2(Elongation) |
- |
500 |
|
- |
| Clause 17 , Table 9 to Table 19(Dimension (Length)) |
- |
200 |
|
- |
| Clause 17 , Table 9 to Table 19(Dimension (Width)) |
- |
200 |
|
- |
| Clause 17 , Table 9 to Table 19(Dimension (Thickness)) |
- |
200 |
|
- |
| Clause 17 , Table 9 to Table 19(Flatness) |
- |
200 |
|
- |
| Clause 17 , Table 9 to Table 19(Camber) |
- |
200 |
|
- |
| Table 1(Any Instrumental Method/Chemical Method) |
- |
2000 |
|
- |
| Table 1, Amendment 2(Any Instrumental Method/Chemical Method) |
- |
2000 |
|
- |
| Table 1, Amendment 2(Any Instrumental Method/Chemical Method) |
- |
2000 |
|
- |
| Table 1, Amendment 2(Any Instrumental Method/Chemical Method) |
- |
2000 |
|
- |
| Table 1, Amendment 2(Any Instrumental Method/Chemical Method) |
- |
2000 |
|
- |
| Table 1, Amendment 2(Any Instrumental Method/Chemical Method) |
- |
2000 |
|
- |
| Table 1, Amendment 2(Any Instrumental Method/Chemical Method) |
- |
2000 |
|
- |
| 10.1 Amd 2(Yeild Strength) |
- |
500 |
|
- |
| 10.1 Amd 2(0.2 Percent Proof Stress) |
- |
500 |
|
- |
| 10.1 Amd 2(Elongation) |
- |
500 |
|
- |
| Clause 17 , Table 9 to Table 19(Dimension (Length)) |
- |
200 |
|
- |
| Clause 17 , Table 9 to Table 19(Dimension (Width)) |
- |
200 |
|
- |
| Clause 17 , Table 9 to Table 19(Dimension (Thickness)) |
- |
200 |
|
- |
| Clause 17 , Table 9 to Table 19(Flatness) |
- |
200 |
|
- |
| Clause 17 , Table 9 to Table 19(Camber) |
- |
200 |
|
- |
| Table 1(Alumium) |
- |
200 |
|
- |
| Table 1, Amendment 2(Zirconium) |
- |
200 |
|
- |
| Table 1, Amendment 2(Tungstun) |
- |
200 |
|
- |
| Table 1, Amendment 2(Tungstun) |
- |
200 |
|
- |
| Table 1, Amendment 2(Ce) |
- |
200 |
|
- |
| Table 1, Amendment 2(Cobalt) |
- |
200 |
|
- |
| Table 1, Amendment 2(Ta) |
- |
200 |
|
- |
| 5.1 - 1(Carbon) |
- |
200 |
|
- |
| 5.1 - 1(Sulphur) |
- |
200 |
|
- |
| 5.1 - 1(Phosphorus) |
- |
200 |
|
- |
| 5.1 - 1(Manganese) |
- |
200 |
|
- |
| 5.1 - 1(Silicon) |
- |
200 |
|
- |
| 5.1 - 1(Nitrogen) |
- |
200 |
|
- |
| 5.1 - 1(Copper) |
- |
200 |
|
- |
| 5.1 - 1(Titanium) |
- |
200 |
|
- |
| 5.1 - 1(Aluminium) |
- |
200 |
|
- |
| 5.1 - 1(Niobium) |
- |
200 |
|
- |
| 5.1 - 1(Nickel) |
- |
200 |
|
- |
| 5.1 - 1(Chromium) |
- |
200 |
|
- |
| 5.1 - 1(Molybdenum) |
- |
200 |
|
- |
| 6(Freedom from defect) |
- |
200 |
|
- |
| 10.1 - 4(Tensile Test) |
- |
500 |
|
- |
| 10.1 - 4(Yield strength) |
- |
500 |
|
- |
| 10.1 - 4(Elongation % on 50mm) |
- |
500 |
|
- |
| 10.2(Hardness Test) |
- |
200 |
|
- |
| 10.3(Bend Test) |
- |
200 |
|
- |
| 11(Erichsen Cupping Test) |
- |
200 |
|
- |
| 17(Dimension and tolerance) |
- |
200 |
|
- |
| 12(Corrosion resistance) |
- |
2000 |
|
- |
| 5.1 - 1(Carbon) |
- |
200 |
|
- |
| 5.1 - 1(Sulphur) |
- |
200 |
|
- |
| 5.1 - 1(Phosphorus) |
- |
200 |
|
- |
| 5.1 - 1(Manganese) |
- |
200 |
|
- |
| 5.1 - 1(Silicon) |
- |
200 |
|
- |
| 5.1 - 1(Nitrogen) |
- |
200 |
|
- |
| 5.1 - 1(Copper) |
- |
200 |
|
- |
| 5.1 - 1(Titanium) |
- |
200 |
|
- |
| 5.1 - 1(Aluminium) |
- |
200 |
|
- |
| 5.1 - 1(Niobium) |
- |
200 |
|
- |
| 5.1 - 1(Nickel) |
- |
200 |
|
- |
| 5.1 - 1(Chromium) |
- |
200 |
|
- |
| 5.1 - 1(Molybdenum) |
- |
200 |
|
- |
| 6(Freedom from defect) |
- |
200 |
|
- |
| 10.1 - 4(Tensile Test) |
- |
500 |
|
- |
| 10.1 - 4(Yield strength) |
- |
500 |
|
- |
| 10.1 - 4(Elongation % on 50mm) |
- |
500 |
|
- |
| 10.2(Hardness Test) |
- |
200 |
|
- |
| 10.3(Bend Test) |
- |
200 |
|
- |
| 11(Erichsen Cupping Test) |
- |
200 |
|
- |
| 17(Dimension and tolerance) |
- |
200 |
|
- |
| 12(Corrosion resistance) |
- |
2000 |
|
- |
| Cl. 7.1 & 7.2 Table 1(Carbon -IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
200 |
|
- |
| Cl. 7.1 & 7.2 Table 1(Silicon -IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
200 |
|
- |
| Cl. 7.1 & 7.2 Table 1(Manganese -IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
200 |
|
- |
| Cl. 7.1 & 7.2 Table 1(Nickel -IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
200 |
|
- |
| Cl. 7.1 & 7.2 Table 1(Chromium -IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
200 |
|
- |
| Cl. 7.1 & 7.2 Table 1(Molybdenum -IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
200 |
|
- |
| Cl. 7.1 & 7.2 Table 1(Sulphur -IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
200 |
|
- |
| Cl. 7.1 & 7.2 Table 1(Phosphorus -IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
200 |
|
- |
| Cl. 7.1 & 7.2 Table 1(Nitrogen -IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
200 |
|
- |
| Cl. 7.1 & 7.2 Table 1(Copper -IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
200 |
|
- |
| Cl. 7.1 & 7.2 Table 1(Others-IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
200 |
|
- |
| Cl. 7.1 & 7.2 Table 1(Titanium-IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
200 |
|
- |
| Cl. 7.1 & 7.2 Table 1(Niobium-IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
200 |
|
- |
| Cl.12(Corrosion Resistance- IS 10461(Part1)) |
- |
2000 |
|
- |
| Cl.12(Corrosion Resistance- IS 10461(Part2)) |
- |
2000 |
|
- |
| 6(Freedom from defects , IS 6911) |
- |
300 |
|
- |
| 10.1,Table 4&Table 6(Tensile Test - IS 1608(Pt -1)) |
- |
800 |
|
- |
| 10.2,Table 4&Table 5(Hardness Test- IS 1500(Pt -1),IS 1501 (Pt-1),IS 1586 (Pt -1)) |
- |
500 |
|
- |
| 10.3(Bend Test - IS 1599) |
- |
500 |
|
- |
| 11,Table 7(Erichsen cupping test-IS 10175) |
- |
500 |
|
- |
| 17(Dimension and tolerance) |
- |
500 |
|
- |
| 10.1 Amd 2(Yeild Strength) |
- |
500 |
|
- |
| 10.1 Amd 2(0.2 Percent Proof Stress) |
- |
500 |
|
- |
| 10.1 Amd 2(Elongation) |
- |
500 |
|
- |
| Clause 17 , Table 9 to Table 19(Dimension (Length)) |
- |
300 |
|
- |
| Clause 17 , Table 9 to Table 19(Dimension (Width)) |
- |
300 |
|
- |
| Clause 17 , Table 9 to Table 19(Dimension (Thickness)) |
- |
300 |
|
- |
| Clause 17 , Table 9 to Table 19(Flatness) |
- |
300 |
|
- |
| Clause 17 , Table 9 to Table 19(Camber) |
- |
300 |
|
- |
| Table 1(Any Instrumental Method/Chemical Method) |
- |
300 |
|
- |
| Table 1, Amendment 2(Any Instrumental Method/Chemical Method) |
- |
300 |
|
- |
| Table 1, Amendment 2(Any Instrumental Method/Chemical Method) |
- |
300 |
|
- |
| Table 1, Amendment 2(Any Instrumental Method/Chemical Method) |
- |
300 |
|
- |
| Table 1, Amendment 2(Any Instrumental Method/Chemical Method) |
- |
300 |
|
- |
| Table 1, Amendment 2(Any Instrumental Method/Chemical Method) |
- |
300 |
|
- |
| 10.1 Amd 2(Yeild Strength) |
- |
500 |
|
- |
| 10.1 Amd 2(0.2 Percent Proof Stress) |
- |
500 |
|
- |
| 10.1 Amd 2(Elongation) |
- |
500 |
|
- |
| Clause 17 , Table 9 to Table 19(Dimension (Length)) |
- |
500 |
|
- |
| Clause 17 , Table 9 to Table 19(Dimension (Width)) |
- |
300 |
|
- |
| Clause 17 , Table 9 to Table 19(Dimension (Thickness)) |
- |
300 |
|
- |
| Clause 17 , Table 9 to Table 19(Flatness) |
- |
300 |
|
- |
| Clause 17 , Table 9 to Table 19(Camber) |
- |
300 |
|
- |
| Table 1(Any Instrumental Method/Chemical Method) |
- |
300 |
|
- |
| Table 1, Amendment 2(Any Instrumental Method/Chemical Method) |
- |
300 |
|
- |
| Table 1, Amendment 2(Any Instrumental Method/Chemical Method) |
- |
300 |
|
- |
| Table 1, Amendment 2(Any Instrumental Method/Chemical Method) |
- |
300 |
|
- |
| Table 1, Amendment 2(Any Instrumental Method/Chemical Method) |
- |
300 |
|
- |
| Table 1, Amendment 2(Any Instrumental Method/Chemical Method) |
- |
300 |
|
- |
| 10.1 Amd 2(Yeild Strength) |
- |
800 |
|
- |
| 10.1 Amd 2(0.2 Percent Proof Stress) |
- |
500 |
|
- |
| 10.1 Amd 2(Elongation) |
- |
500 |
|
- |
| Clause 17 , Table 9 to Table 19(Dimension (Length)) |
- |
500 |
|
- |
| Clause 17 , Table 9 to Table 19(Dimension (Width)) |
- |
500 |
|
- |
| 10.1 Amd 2(Yeild Strength) |
- |
500 |
|
- |
| 10.1 Amd 2(0.2 Percent Proof Stress) |
- |
500 |
|
- |
| 10.1 Amd 2(Yeild Strength) |
- |
500 |
|
- |
| 10.1 Amd 2(0.2 Percent Proof Stress) |
- |
500 |
|
- |
| 10.1 Amd 2(Elongation) |
- |
500 |
|
- |
| Clause 17 , Table 9 to Table 19(Dimension (Length)) |
- |
500 |
|
- |
| Clause 17 , Table 9 to Table 19(Dimension (Width)) |
- |
300 |
|
- |
| Clause 17 , Table 9 to Table 19(Dimension (Thickness)) |
- |
300 |
|
- |
| Clause 17 , Table 9 to Table 19(Flatness) |
- |
300 |
|
- |
| Clause 17 , Table 9 to Table 19(Camber) |
- |
300 |
|
- |
| Table 1(Any Instrumental Method/Chemical Method) |
- |
300 |
|
- |
| Table 1, Amendment 2(Any Instrumental Method/Chemical Method) |
- |
300 |
|
- |
| Table 1, Amendment 2(Any Instrumental Method/Chemical Method) |
- |
300 |
|
- |
| Table 1, Amendment 2(Any Instrumental Method/Chemical Method) |
- |
300 |
|
- |
| Table 1, Amendment 2(Any Instrumental Method/Chemical Method) |
- |
300 |
|
- |
| Table 1, Amendment 2(Any Instrumental Method/Chemical Method) |
- |
300 |
|
- |
| Table 1, Amendment 2(Any Instrumental Method/Chemical Method) |
- |
300 |
|
- |
| 10.1 Amd 2(Yeild Strength) |
- |
500 |
|
- |
| 10.1 Amd 2(0.2 Percent Proof Stress) |
- |
500 |
|
- |
| 10.1 Amd 2(Elongation) |
- |
500 |
|
- |
| Clause 17 , Table 9 to Table 19(Dimension (Length)) |
- |
300 |
|
- |
| Clause 17 , Table 9 to Table 19(Dimension (Width)) |
- |
500 |
|
- |
| Clause 17 , Table 9 to Table 19(Dimension (Thickness)) |
- |
500 |
|
- |
| Clause 17 , Table 9 to Table 19(Flatness) |
- |
500 |
|
- |
| Clause 17 , Table 9 to Table 19(Camber) |
- |
500 |
|
- |
| Table 1(Alumium) |
- |
300 |
|
- |
| Table 1, Amendment 2(Zirconium) |
- |
300 |
|
- |
| Table 1, Amendment 2(Tungstun) |
- |
300 |
|
- |
| Table 1, Amendment 2(Tungstun) |
- |
300 |
|
- |
| Table 1, Amendment 2(Ce) |
- |
300 |
|
- |
| Table 1, Amendment 2(Cobalt) |
- |
300 |
|
- |
| Table 1, Amendment 2(Ta) |
- |
300 |
|
- |
| 5.1 - 1(Carbon) |
- |
300 |
|
- |
| 5.1 - 1(Sulphur) |
- |
300 |
|
- |
| 5.1 - 1(Phosphorus) |
- |
300 |
|
- |
| 5.1 - 1(Manganese) |
- |
300 |
|
- |
| 5.1 - 1(Silicon) |
- |
300 |
|
- |
| 5.1 - 1(Nitrogen) |
- |
300 |
|
- |
| 5.1 - 1(Copper) |
- |
300 |
|
- |
| 5.1 - 1(Titanium) |
- |
300 |
|
- |
| 5.1 - 1(Aluminium) |
- |
300 |
|
- |
| 5.1 - 1(Niobium) |
- |
300 |
|
- |
| 5.1 - 1(Nickel) |
- |
300 |
|
- |
| 5.1 - 1(Chromium) |
- |
300 |
|
- |
| 5.1 - 1(Molybdenum) |
- |
300 |
|
- |
| 6(Freedom from defect) |
- |
300 |
|
- |
| 10.1 - 4(Tensile Test) |
- |
800 |
|
- |
| 10.1 - 4(Yield strength) |
- |
500 |
|
- |
| 10.1 - 4(Elongation % on 50mm) |
- |
500 |
|
- |
| 10.2(Hardness Test) |
- |
500 |
|
- |
| 10.3(Bend Test) |
- |
500 |
|
- |
| 11(Erichsen Cupping Test) |
- |
500 |
|
- |
| 17(Dimension and tolerance) |
- |
500 |
|
- |
| 12(Corrosion resistance) |
- |
2000 |
|
- |
| 5.1 - 1(Carbon) |
- |
200 |
|
- |
| 5.1 - 1(Sulphur) |
- |
200 |
|
- |
| 5.1 - 1(Phosphorus) |
- |
200 |
|
- |
| 5.1 - 1(Manganese) |
- |
200 |
|
- |
| 5.1 - 1(Silicon) |
- |
200 |
|
- |
| 5.1 - 1(Nitrogen) |
- |
200 |
|
- |
| 5.1 - 1(Copper) |
- |
200 |
|
- |
| 5.1 - 1(Titanium) |
- |
200 |
|
- |
| 5.1 - 1(Aluminium) |
- |
200 |
|
- |
| 5.1 - 1(Niobium) |
- |
200 |
|
- |
| 5.1 - 1(Nickel) |
- |
200 |
|
- |
| 5.1 - 1(Chromium) |
- |
200 |
|
- |
| 5.1 - 1(Molybdenum) |
- |
200 |
|
- |
| 6(Freedom from defect) |
- |
500 |
|
- |
| 10.1 - 4(Tensile Test) |
- |
800 |
|
- |
| 10.1 - 4(Yield strength) |
- |
500 |
|
- |
| 10.1 - 4(Elongation % on 50mm) |
- |
500 |
|
- |
| 10.2(Hardness Test) |
- |
500 |
|
- |
| 10.3(Bend Test) |
- |
500 |
|
- |
| 11(Erichsen Cupping Test) |
- |
500 |
|
- |
| 17(Dimension and tolerance) |
- |
300 |
|
- |
| 12(Corrosion resistance) |
- |
2000 |
|
- |
| Cl. 7.1 & 7.2 Table 1(Carbon -IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
200 |
|
- |
| Cl. 7.1 & 7.2 Table 1(Silicon -IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
200 |
|
- |
| Cl. 7.1 & 7.2 Table 1(Manganese -IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
200 |
|
- |
| Cl. 7.1 & 7.2 Table 1(Nickel -IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
200 |
|
- |
| Cl. 7.1 & 7.2 Table 1(Chromium -IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
200 |
|
- |
| Cl. 7.1 & 7.2 Table 1(Molybdenum -IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
200 |
|
- |
| Cl. 7.1 & 7.2 Table 1(Sulphur -IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
200 |
|
- |
| Cl. 7.1 & 7.2 Table 1(Phosphorus -IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
200 |
|
- |
| Cl. 7.1 & 7.2 Table 1(Nitrogen -IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
200 |
|
- |
| Cl. 7.1 & 7.2 Table 1(Copper -IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
200 |
|
- |
| Cl. 7.1 & 7.2 Table 1(Others-IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
200 |
|
- |
| Cl. 7.1 & 7.2 Table 1(Titanium-IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
200 |
|
- |
| Cl. 7.1 & 7.2 Table 1(Niobium-IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
200 |
|
- |
| Cl.12(Corrosion Resistance- IS 10461(Part1)) |
- |
1500 |
|
- |
| Cl.12(Corrosion Resistance- IS 10461(Part2)) |
- |
1500 |
|
- |
| 6(Freedom from defects , IS 6911) |
- |
200 |
|
- |
| 10.1,Table 4&Table 6(Tensile Test - IS 1608(Pt -1)) |
- |
1000 |
|
- |
| 10.2,Table 4&Table 5(Hardness Test- IS 1500(Pt -1),IS 1501 (Pt-1),IS 1586 (Pt -1)) |
- |
500 |
|
- |
| 10.3(Bend Test - IS 1599) |
- |
1500 |
|
- |
| 11,Table 7(Erichsen cupping test-IS 10175) |
- |
1000 |
|
- |
| 17(Dimension and tolerance) |
- |
500 |
|
- |
| 10.1 Amd 2(Yeild Strength) |
- |
1500 |
|
- |
| 10.1 Amd 2(0.2 Percent Proof Stress) |
- |
1500 |
|
- |
| 10.1 Amd 2(Elongation) |
- |
1500 |
|
- |
| Clause 17 , Table 9 to Table 19(Dimension (Length)) |
- |
500 |
|
- |
| Clause 17 , Table 9 to Table 19(Dimension (Width)) |
- |
500 |
|
- |
| Clause 17 , Table 9 to Table 19(Dimension (Thickness)) |
- |
500 |
|
- |
| Clause 17 , Table 9 to Table 19(Flatness) |
- |
500 |
|
- |
| Clause 17 , Table 9 to Table 19(Camber) |
- |
500 |
|
- |
| Table 1(Any Instrumental Method/Chemical Method) |
- |
200 |
|
- |
| Table 1, Amendment 2(Any Instrumental Method/Chemical Method) |
- |
200 |
|
- |
| Table 1, Amendment 2(Any Instrumental Method/Chemical Method) |
- |
200 |
|
- |
| Table 1, Amendment 2(Any Instrumental Method/Chemical Method) |
- |
200 |
|
- |
| Table 1, Amendment 2(Any Instrumental Method/Chemical Method) |
- |
200 |
|
- |
| Table 1, Amendment 2(Any Instrumental Method/Chemical Method) |
- |
200 |
|
- |
| 10.1 Amd 2(Yeild Strength) |
- |
200 |
|
- |
| 10.1 Amd 2(0.2 Percent Proof Stress) |
- |
200 |
|
- |
| 10.1 Amd 2(Elongation) |
- |
200 |
|
- |
| Clause 17 , Table 9 to Table 19(Dimension (Length)) |
- |
200 |
|
- |
| Clause 17 , Table 9 to Table 19(Dimension (Width)) |
- |
200 |
|
- |
| Clause 17 , Table 9 to Table 19(Dimension (Thickness)) |
- |
200 |
|
- |
| Clause 17 , Table 9 to Table 19(Flatness) |
- |
200 |
|
- |
| Clause 17 , Table 9 to Table 19(Camber) |
- |
200 |
|
- |
| Table 1(Any Instrumental Method/Chemical Method) |
- |
200 |
|
- |
| Table 1, Amendment 2(Any Instrumental Method/Chemical Method) |
- |
200 |
|
- |
| Table 1, Amendment 2(Any Instrumental Method/Chemical Method) |
- |
200 |
|
- |
| Table 1, Amendment 2(Any Instrumental Method/Chemical Method) |
- |
200 |
|
- |
| Table 1, Amendment 2(Any Instrumental Method/Chemical Method) |
- |
200 |
|
- |
| Table 1, Amendment 2(Any Instrumental Method/Chemical Method) |
- |
200 |
|
- |
| 10.1 Amd 2(Yeild Strength) |
- |
1500 |
|
- |
| 10.1 Amd 2(0.2 Percent Proof Stress) |
- |
1500 |
|
- |
| 10.1 Amd 2(Elongation) |
- |
1500 |
|
- |
| Clause 17 , Table 9 to Table 19(Dimension (Length)) |
- |
500 |
|
- |
| Clause 17 , Table 9 to Table 19(Dimension (Width)) |
- |
500 |
|
- |
| 10.1 Amd 2(Yeild Strength) |
- |
1500 |
|
- |
| 10.1 Amd 2(0.2 Percent Proof Stress) |
- |
1500 |
|
- |
| 10.1 Amd 2(Yeild Strength) |
- |
1500 |
|
- |
| 10.1 Amd 2(0.2 Percent Proof Stress) |
- |
1500 |
|
- |
| 10.1 Amd 2(Elongation) |
- |
1500 |
|
- |
| Clause 17 , Table 9 to Table 19(Dimension (Length)) |
- |
500 |
|
- |
| Clause 17 , Table 9 to Table 19(Dimension (Width)) |
- |
500 |
|
- |
| Clause 17 , Table 9 to Table 19(Dimension (Thickness)) |
- |
500 |
|
- |
| Clause 17 , Table 9 to Table 19(Flatness) |
- |
500 |
|
- |
| Clause 17 , Table 9 to Table 19(Camber) |
- |
500 |
|
- |
| Table 1(Any Instrumental Method/Chemical Method) |
- |
200 |
|
- |
| Table 1, Amendment 2(Any Instrumental Method/Chemical Method) |
- |
200 |
|
- |
| Table 1, Amendment 2(Any Instrumental Method/Chemical Method) |
- |
200 |
|
- |
| Table 1, Amendment 2(Any Instrumental Method/Chemical Method) |
- |
200 |
|
- |
| Table 1, Amendment 2(Any Instrumental Method/Chemical Method) |
- |
200 |
|
- |
| Table 1, Amendment 2(Any Instrumental Method/Chemical Method) |
- |
200 |
|
- |
| Table 1, Amendment 2(Any Instrumental Method/Chemical Method) |
- |
200 |
|
- |
| 10.1 Amd 2(Yeild Strength) |
- |
1500 |
|
- |
| 10.1 Amd 2(0.2 Percent Proof Stress) |
- |
1500 |
|
- |
| 10.1 Amd 2(Elongation) |
- |
1500 |
|
- |
| Clause 17 , Table 9 to Table 19(Dimension (Length)) |
- |
500 |
|
- |
| Clause 17 , Table 9 to Table 19(Dimension (Width)) |
- |
500 |
|
- |
| Clause 17 , Table 9 to Table 19(Dimension (Thickness)) |
- |
500 |
|
- |
| Clause 17 , Table 9 to Table 19(Flatness) |
- |
500 |
|
- |
| Clause 17 , Table 9 to Table 19(Camber) |
- |
500 |
|
- |
| Table 1(Alumium) |
- |
200 |
|
- |
| Table 1, Amendment 2(Zirconium) |
- |
200 |
|
- |
| Table 1, Amendment 2(Tungstun) |
- |
200 |
|
- |
| Table 1, Amendment 2(Tungstun) |
- |
200 |
|
- |
| Table 1, Amendment 2(Ce) |
- |
200 |
|
- |
| Table 1, Amendment 2(Cobalt) |
- |
200 |
|
- |
| Table 1, Amendment 2(Ta) |
- |
200 |
|
- |
| 5.1 - 1(Carbon) |
- |
200 |
|
- |
| 5.1 - 1(Sulphur) |
- |
200 |
|
- |
| 5.1 - 1(Phosphorus) |
- |
200 |
|
- |
| 5.1 - 1(Manganese) |
- |
200 |
|
- |
| 5.1 - 1(Silicon) |
- |
200 |
|
- |
| 5.1 - 1(Nitrogen) |
- |
200 |
|
- |
| 5.1 - 1(Copper) |
- |
200 |
|
- |
| 5.1 - 1(Titanium) |
- |
200 |
|
- |
| 5.1 - 1(Aluminium) |
- |
200 |
|
- |
| 5.1 - 1(Niobium) |
- |
200 |
|
- |
| 5.1 - 1(Nickel) |
- |
200 |
|
- |
| 5.1 - 1(Chromium) |
- |
200 |
|
- |
| 5.1 - 1(Molybdenum) |
- |
200 |
|
- |
| 6(Freedom from defect) |
- |
500 |
|
- |
| 10.1 - 4(Tensile Test) |
- |
1500 |
|
- |
| 10.1 - 4(Yield strength) |
- |
1500 |
|
- |
| 10.1 - 4(Elongation % on 50mm) |
- |
1500 |
|
- |
| 10.2(Hardness Test) |
- |
500 |
|
- |
| 10.3(Bend Test) |
- |
1500 |
|
- |
| 11(Erichsen Cupping Test) |
- |
1500 |
|
- |
| 17(Dimension and tolerance) |
- |
500 |
|
- |
| 12(Corrosion resistance) |
- |
1500 |
|
- |
| 5.1 - 1(Carbon) |
- |
200 |
|
- |
| 5.1 - 1(Sulphur) |
- |
200 |
|
- |
| 5.1 - 1(Phosphorus) |
- |
200 |
|
- |
| 5.1 - 1(Manganese) |
- |
200 |
|
- |
| 5.1 - 1(Silicon) |
- |
200 |
|
- |
| 5.1 - 1(Nitrogen) |
- |
200 |
|
- |
| 5.1 - 1(Copper) |
- |
200 |
|
- |
| 5.1 - 1(Titanium) |
- |
200 |
|
- |
| 5.1 - 1(Aluminium) |
- |
200 |
|
- |
| 5.1 - 1(Niobium) |
- |
200 |
|
- |
| 5.1 - 1(Nickel) |
- |
200 |
|
- |
| 5.1 - 1(Chromium) |
- |
200 |
|
- |
| 5.1 - 1(Molybdenum) |
- |
200 |
|
- |
| 6(Freedom from defect) |
- |
500 |
|
- |
| 10.1 - 4(Tensile Test) |
- |
1500 |
|
- |
| 10.1 - 4(Yield strength) |
- |
1500 |
|
- |
| 10.1 - 4(Elongation % on 50mm) |
- |
1500 |
|
- |
| 10.2(Hardness Test) |
- |
500 |
|
- |
| 10.3(Bend Test) |
- |
1500 |
|
- |
| 11(Erichsen Cupping Test) |
- |
1500 |
|
- |
| 17(Dimension and tolerance) |
- |
500 |
|
- |
| 12(Corrosion resistance) |
- |
1500 |
|
- |
|
- |
- Included w.e.f. 10.01.2025 |
| 7474 |
AADHAR TESTING SOLUTIONS LLP, GHAZIABAD
| 8185026
| IS 694 (2010) |
Polyvinyl chloride insulated unsheathed and sheathed cables/cords with rigid and flexible conductor for rated voltages up to and including 450/750 v (Fourth Revision) |
450/750 V |
32500.0 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 10.9(Additional ageing test (OU cables only) -HV test (at 60±3oC)) |
- |
4500.00 |
|
30% Discount for BIS |
| 10.4(Flammability test- Unaffected portion) |
- |
750.00 |
|
30% Discount for BIS |
| 10.4(Flammability test-Burning after flame removal) |
- |
750.00 |
|
30% Discount for BIS |
| table 1 e) 3) (IR constant- max. Temp) |
- |
1500.00 |
|
30% Discount for BIS |
| table 1 e) 3) (IR constant- Room temp ) |
- |
500.00 |
|
30% Discount for BIS |
| table 1 e) 3) (Volume Resistivity - Maximum temp) |
- |
1500.00 |
|
30% Discount for BIS |
| table 1 e) 3) (Volume Resistivity - Room temp ) |
- |
500.00 |
|
30% Discount for BIS |
| 10.2(HV (room temperature)) |
- |
500.00 |
|
30% Discount for BIS |
| 10.1(HV (water immersion)) |
- |
2500.00 |
|
30% Discount for BIS |
| 10.8(Smoke density rating) |
- |
2500.00 |
|
30% Discount for BIS |
| 10.6(Halogen evolution) |
- |
3000.00 |
|
30% Discount for BIS |
| 10.7(Temperature index) |
- |
2500.00 |
|
30% Discount for BIS |
| 10.5(Oxygen index) |
- |
2500.00 |
|
30% Discount for BIS |
| Table 1 iii) d) 9)(Cold impact for sheath) |
- |
500.00 |
|
30% Discount for BIS |
| Table 1 iii) d) 8)(Cold bend for sheath) |
- |
500.00 |
|
30% Discount for BIS |
| Table 1 iii) c) 9)(Cold impact for insulation) |
- |
500.00 |
|
30% Discount for BIS |
| Table 1 iii) c) 8)(Cold bend for insulation) |
- |
500.00 |
|
30% Discount for BIS |
| Table 1 iii) d) 7)(Thermal stability- Sheath ) |
- |
1000.00 |
|
30% Discount for BIS |
| Table 1 iii) c) 7)(Thermal stability- Insulation ) |
- |
1000.00 |
|
30% Discount for BIS |
| Table 1 iii) d) 6)(Hot deformation -Indentation depth - Sheath ) |
- |
1000.00 |
|
30% Discount for BIS |
| Table 1 iii) c) 6)(Hot deformation - Indentation depth- Insulation) |
- |
1000.00 |
|
30% Discount for BIS |
| Table 1 iii) d) 5)(Heat shock-Sheath ) |
- |
500.00 |
|
30% Discount for BIS |
| Table 1 iii) c) 5)(Heat shock-Insulation ) |
- |
500.00 |
|
30% Discount for BIS |
| Table 1 iii) d) 4)(Shrinkage- Sheath ) |
- |
500.00 |
|
30% Discount for BIS |
| Table 1 iii) c) 4)(Shrinkage-Insulation) |
- |
500.00 |
|
30% Discount for BIS |
| Table 1 iii) d) 2)(Loss of mass- Sheath ) |
- |
2500.00 |
|
30% Discount for BIS |
| Table 1 iii) c) 2)(Loss of mass- Insulation ) |
- |
2500.00 |
|
30% Discount for BIS |
| Table 1 iii) d) 3)(Sheath- Elongation variation) |
- |
2500.00 |
|
30% Discount for BIS |
| Table 1 iii) d) 3)(Sheath- TS variation) |
- |
2500.00 |
|
30% Discount for BIS |
| Table 1 iii) d) 3)(Sheath- Elongation (After ageing)) |
- |
2500.00 |
|
30% Discount for BIS |
| Table 1 iii) d) 3)(Sheath- Tensile strength (After ageing)) |
- |
2500.00 |
|
30% Discount for BIS |
| Table 1 iii) d) 1)(Sheath- Elongation (Without ageing)) |
- |
500.00 |
|
30% Discount for BIS |
| Table 1 iii) d) 1)(Sheath -Tensile strength (Without ageing)) |
- |
500.00 |
|
30% Discount for BIS |
| 8.3(Thickness of Sheath) |
- |
500.00 |
|
30% Discount for BIS |
| 5.3(Thickness of Insulation) |
- |
500.00 |
|
30% Discount for BIS |
| 9(Overall dimensions) |
- |
200.00 |
|
30% Discount for BIS |
| 10.11(Per sulphate test (for tinned Cu cable only)) |
- |
2500.00 |
|
30% Discount for BIS |
| 4.2(Conductor resistance test) |
- |
1100.00 |
|
30% Discount for BIS |
| 4.1(Tensile test (for Al)-Before Stranding) |
- |
500.00 |
|
30% Discount for BIS |
| 4.1(Annealing test (for copper)) |
- |
500.00 |
|
30% Discount for BIS |
| 4.1(Wrapping test (for Al)) |
- |
500.00 |
|
30% Discount for BIS |
| 9.1(Ovality) |
- |
200.00 |
|
30% Discount for BIS |
| Table 1 iii) c) 1)(Elongation (Without ageing)) |
- |
500.00 |
|
30% Discount for BIS |
| Table 1 iii) c) 1)(Tensile strength (Without ageing)) |
- |
500.00 |
|
30% Discount for BIS |
| 11(Identification) |
- |
0.00 |
|
- |
| 13(Cable code) |
- |
0.00 |
|
- |
| 11.2(Legibility) |
- |
0.00 |
|
- |
| 11.1(Durability) |
- |
200.00 |
|
30% Discount for BIS |
| (Cl.6.1.3 of IS 8130:2013)(Solid Conductor (Class 1)) |
- |
0.00 |
|
- |
| Cl. 8.2(Application of Sheath) |
- |
0.00 |
|
- |
| Cl.19.1.4(Assembly of Cores) |
- |
0.00 |
|
- |
| ( 6.4.3 of IS 8130:2013)(Flexible Conductors (Class 5)) |
- |
0.00 |
|
-- |
| (6.4.2 of IS 8130:2013)(Flexible Conductors (Class 5)) |
- |
0.00 |
|
- |
| ( 6.4.1 of IS 8130:2013)(Flexible Conductors (Class 5)) |
- |
0.00 |
|
- |
| (6.3.3 of IS 8130:2013)(Stranded Compacted Circular Conductors and Shaped Conductors (Class 2)) |
- |
0.00 |
|
- |
| (6.3.2 of IS 8130:2013)(Stranded Compacted Circular Conductors and Shaped Conductors (Class 2)) |
- |
0.00 |
|
- |
| (6.3.1 of IS 8130:2013)(Stranded Compacted Circular Conductors and Shaped Conductors (Class 2)) |
- |
0.00 |
|
- |
| (6.2.3 of IS 8130:2013)(Stranded Circular Non-compacted Conductors (Class 2)) |
- |
0.00 |
|
- |
| (6.2.2 of IS 8130:2013)(Stranded Circular Non-compacted Conductors (Class 2)) |
- |
0.00 |
|
- |
| (6.2.1 of IS 8130:2013)(Stranded Circular Non-compacted Conductors (Class 2)) |
- |
0.00 |
|
- |
| (Cl.6.1.2 of IS 8130:2013)(Solid Conductor (Class 1)) |
- |
0.00 |
|
- |
| (Cl.6.1.1 of IS 8130:2013)(Solid Conductor (Class 1)) |
- |
0.00 |
|
- |
| (4.4.2 of IS 8130:2013)(Joints in Conductor Solid Conductors (Aluminium Conductors only)) |
- |
0.00 |
|
- |
| ( 4.4.1 of IS 8130:2013)(Joints in Conductor) |
- |
0.00 |
|
- |
| (4.3 of IS 8130:2013)(Form of Conductor) |
- |
0.00 |
|
- |
| 22(TWO AND THREE CORE FLAT CABLES WITH PVC INSULATION
AND SHEATHED (CLASS 2 OR 5) FOR GENERAL PURPOSE( FOR MAXIMUM CONDUCTOR TEMPERA TURE 70°C OR 85°C)) |
- |
0.00 |
|
- |
| 21(ARALLEL TWIN AND TWISTED TWIN FLEXIBLE PVC INSULATED
UNSHEATHED CORDS (CLASS 5) FOR GENERAL PURPOSE (FOR MAXIMUM CONDUCTOR TEMPERATURE 70°C OR 85°C)) |
- |
0.00 |
|
- |
| 20(MULTICORE CIRCULAR PVC INSULATED AND SHEATHED
CABLES WITH FLEXIBLE CONDUCTOR (CLASS 5) FOR GENERAL PURPOSE (FOR MAXIMUM CONDUCTOR TEMPERATURE 70°C OR 85°C)) |
- |
0.00 |
|
- |
| 19(SINGLE AND MULTICORE CIRCULAR PVC INSULATED AND SHEATHED CABLES/CORDS WITH FLEXIBLE CONDUCTOR (CLASS 5)
FOR GENERAL PURPOSE (MAXIMUM CONDUCTOR TEMPERATURE 70°C OR 85°C)) |
- |
0.00 |
|
- |
| 18(SINGLE AND MULTICORE CIRCULAR PVC INSULATED
AND SHEATHED CABLES WITH RIGID CONDUCTOR (CLASS 1 AND CLASS 2) FOR GENERAL PURPOSE ) FOR MAXIMUM CONDUCTOR TEMPERATURE (70°C OR 85°C)) |
- |
0.00 |
|
- |
| 17(SINGLE CORE NON-SHEATHED CABLES WITH
FLEXIBLE CONDUCTOR FOR GENERAL PURPOSE (MAXIMUM CONDUCTOR TEMPERATURE 70°C OR 85°C)) |
- |
0.00 |
|
- |
| 16.2(Tests) |
- |
0.00 |
|
-- |
| 16.1(Construction) |
- |
0.00 |
|
- |
| (Cl.6.1.3 of IS 8130:2013)(Flexible Conductors (Classes 5)) |
- |
0.00 |
|
- |
| (Cl.6.1.3 of IS 8130:2013)( Flexible Conductors (Classes 5)) |
- |
0.00 |
|
- |
| (Cl.6.1.3 of IS 8130:2013)(Stranded circular non compacted conductors(Class-2)) |
- |
0.00 |
|
- |
| (Cl.6.1.3 of IS 8130:2013)(Stranded compacted circular conductors and shaped conductors (Class 2)) |
- |
0.00 |
|
- |
| (Cl.6.1.3 of IS 8130:2013)(Stranded circular non compacted conductors (Class-2)) |
- |
0.00 |
|
- |
| (Cl.6.1.3 of IS 8130:2013)(Stranded circular non compacted conductors (Class-2)) |
- |
0.00 |
|
- |
| (Cl.6.1.3 of IS 8130:2013)(Solid Conductor (Class 1)) |
- |
0.00 |
|
- |
| (Cl.6.1 of IS 8130:2013)(Solid Conductor (Class 1)) |
- |
0.00 |
|
- |
| (Cl.6.1 of IS 8130:2013)(Solid Conductor (Class 1)) |
- |
0.00 |
|
- |
| (Cl.16.1)
(Cl.19.1)(Conductor- Diameter ) |
- |
200.00 |
|
30% Discount for BIS |
| (Cl.16.1)
(Cl.19.1)(Conductor) |
- |
0.00 |
|
- |
| (Cl.16.1)
(Cl.19.1)(Conductor) |
- |
0.00 |
|
- |
| (Cl.16.1)
(Cl.19.1)(Conductor) |
- |
0.00 |
|
- |
| (Cl. 18.1.3)
(Cl. 19.1.4)
(Cl. 20.1.3)
(Cl. 21.1.3)
(Cl. 22.1.3)(Assembly of cores ) |
- |
0.00 |
|
- |
| 12(CONSTRUCTION Core Identification) |
- |
200.00 |
|
30% Discount for BIS |
| 8.1(Sheath Material ) |
- |
0.00 |
|
-- |
| 7(Binder Tape) |
- |
0.00 |
|
30% Discount for BIS |
| (Cl. 18.1.4)
(Cl. 19.1.5)
(Cl. 20.1.4)
(Cl. 22.1.4)(Colour of Sheath) |
- |
100.00 |
|
30% Discount for BIS |
| 5.2(Application ) |
- |
0.00 |
|
-- |
| 4.1(Conductor - Material) |
- |
0.00 |
|
-- |
| 4.4(Joints in Conductor) |
- |
0.00 |
|
-- |
| 12.0(Core identification) |
- |
100.00 |
|
30% Discount for BIS |
| 10.11(Persulphate Test) |
- |
2500.00 |
|
30% Discount for BIS |
| 4.1(Material) |
- |
0.00 |
|
30% Discount for BIS |
| 5(INSULATION) |
- |
0.00 |
|
-- |
| 6(FILLER) |
- |
0.00 |
|
-- |
| 7(BINDER TAPE) |
- |
0.00 |
|
-- |
| 8(SHEATH) |
- |
0.00 |
|
-- |
| 9(OVERALL DIMENSIONS) |
- |
200.00 |
|
30% Discount for BIS |
| 10.1(High Voltage Test (Water Immersion Test)) |
- |
2500.00 |
|
30% Discount for BIS |
| 10.2(High Voltage Test (at Room Temperature)) |
- |
500.00 |
|
30% Discount for BIS |
| 10.3(Spark Test) |
- |
0.00 |
|
-- |
| 10.4(Flammability Test) |
- |
1500.00 |
|
30% Discount for BIS |
| 10.5(Oxygen Index Test) |
- |
2500.00 |
|
30% Discount for BIS |
| 10.6(Test for Halogen Acid Gas Evolution) |
- |
3000.00 |
|
30% Discount for BIS |
| 10.7(Test for Temperature Index) |
- |
2500.0 |
|
30% Discount for BIS |
| 10.8(Smoke Density Rating) |
- |
2500.00 |
|
30% Discount for BIS |
| 10.9(Additional Ageing Test (for Cables for Outdoor Use) |
- |
4500.00 |
|
30% Discount for BIS |
| 10.1(Flex Test) |
- |
0.00 |
|
-- |
| 11(IDENTIFICATION) |
- |
500.00 |
|
30% Discount for BIS |
| 12(CORE IDENTIFICATION) |
- |
500.00 |
|
30% Discount for BIS |
| 13(CABLE CODE) |
- |
200.00 |
|
30% Discount for BIS |
| 15(PACKING AND MARKING) |
- |
0.00 |
|
-- |
| Table 1 iii) d) 4)(Cracks Observed) |
- |
500.00 |
|
30% Discount for BIS |
| Table 1 iii) c) 4)(Cracks Observed) |
- |
500.00 |
|
30% Discount for BIS |
| Table 1 iii) c) 3)(Elongation (After ageing)) |
- |
2500.00 |
|
30% Discount for BIS |
| Table 1 iii) c) 3)(TS variation) |
- |
2500.00 |
|
30% Discount for BIS |
| 4.1(Tensile test (for Al)- After Stranding) |
- |
500.00 |
|
30% Discount for BIS |
| 6.2(Filler) |
- |
0.00 |
|
-- |
| 6.1(Filler) |
- |
0.00 |
|
-- |
| 5.1(Insulation) |
- |
0.00 |
|
-- |
| 4.4(Joints in Conductor) |
- |
0.00 |
|
- |
| 4.1(Conductor - Material) |
- |
0.00 |
|
- |
| 10.11(Persulphate Test ) |
- |
2500.00 |
|
30% Discount for BIS |
| Table 2, IS 8130(No fo wire in a conductor) |
- |
200.00 |
|
30% Discount for BIS |
| 8.3(Minimum thickness of Sheath) |
- |
500.00 |
|
30% Discount for BIS |
| 8.3(Avarage thickness of Sheath) |
- |
500.00 |
|
30% Discount for BIS |
| 5.3(Minimum thickness of insulation) |
- |
500.00 |
|
30% Discount for BIS |
| 5.3(Avarage thickness of insulation) |
- |
500.00 |
|
30% Discount for BIS |
| 10.3(Spark test) |
- |
0.00 |
|
- |
| table 1, 4.2(insulation resistance test) |
- |
1500.00 |
|
30% Discount for BIS |
| 5.4(Mechanical properties before and after ageing) |
- |
5000.00 |
|
30% Discount for BIS |
| 10.1(HV (water immersion)) |
- |
2500.00 |
|
30% Discount for BIS |
| Table 1(Category Code) |
- |
0.00 |
|
-- |
| Table 1 iii) c) 3)(Elongation variation) |
- |
2500.00 |
|
30% Discount for BIS |
| Table 1 iii) c) 3)(Tensile strength (After ageing)) |
- |
2500.00 |
|
30% Discount for BIS |
| 4, IS 8130(Construction of conductor) |
- |
0.00 |
|
-- |
| 4.2(Electrical Resistance) |
- |
1500.00 |
|
30% Discount for BIS |
| 10.3(Spark Test) |
- |
0.00 |
|
-- |
|
01 May, 2028 |
- Exclusion: Table 4 (Copper purity test) |
| 7475 |
DELHI TEST HOUSE, Azadhpur
| 8131406
| IS 1151 (2021) |
Refined sugar - Specification Second Revision |
- |
15500 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4.1(Description) |
- |
500 |
|
COMPLETE TESTING - 15500/- |
| 4.2, Table No.1 , 1) , i)(Loss on drying percent by mass, Max) |
- |
800 |
|
COMPLETE TESTING - 15500/- |
| 4.2, Table No.1 , 1) , ii)(Reducing sugar, percent by mass, Max) |
- |
1200 |
|
COMPLETE TESTING - 15500/- |
| 4.2, Table No.1 , 1) , ii)(Polarization, °Z, Min,) |
- |
1000 |
|
COMPLETE TESTING - 15500/- |
| 4.2, Table No.1 , 1) , iv)(Reducing sugar, percent by mass, Max) |
- |
1200 |
|
COMPLETE TESTING - 15500/- |
| 4.2, Table No.1 , 1) , iii)(Reducing sugar, percent by mass, Max) |
- |
1200 |
|
COMPLETE TESTING - 15500/- |
| 4.2, Table No.1 , 1) , iv)(Colour in ICUMSA units, Max) |
- |
3000 |
|
COMPLETE TESTING - 15500/- |
| 4.2, Table No.1 , 1) , v)(Conductivity ash, percent by mass, Max) |
- |
2000 |
|
COMPLETE TESTING - 15500/- |
| 4.2, Table No.1 , 1) , vi)(Sulphur dioxide, mg/kg, Max) |
- |
2000 |
|
COMPLETE TESTING - 15500/- |
| 4.2, Table No.1 , 1) , vii)(Lead, mg/kg, Max) |
- |
500 |
|
COMPLETE TESTING - 15500/- |
| 4.2, Table No.1 , 1) , viii)(Chromium, µg/mg, Max) |
- |
500 |
|
COMPLETE TESTING - 15500/- |
| 4.2, Table No.1 , 1) , ix)(Sediment mg/kg Max) |
- |
500 |
|
COMPLETE TESTING - 15500/- |
| 4.2, Table No.1 , 1) , x)(Iron mg/kg Max) |
- |
500 |
|
COMPLETE TESTING - 15500/- |
| 4.2, Table No.1 , 1) , xi)(Floc test) |
- |
500 |
|
COMPLETE TESTING - 15500/- |
| 4.1(Description) |
- |
0 |
|
COMPLETE TESTING - 15500/- |
| 4.2, Table No.1 , 1) , i)(Loss on drying percent by mass, Max) |
- |
0 |
|
COMPLETE TESTING - 15500/- |
| 4.2, Table No.1 , 1) , ii)(Reducing sugar, percent by mass, Max) |
- |
0 |
|
COMPLETE TESTING - 15500/- |
| 4.2, Table No.1 , 1) , ii)(Polarization, °Z, Min,) |
- |
0 |
|
COMPLETE TESTING - 15500/- |
| 4.2, Table No.1 , 1) , iv)(Reducing sugar, percent by mass, Max) |
- |
0 |
|
COMPLETE TESTING - 15500/- |
| 4.2, Table No.1 , 1) , iii)(Reducing sugar, percent by mass, Max) |
- |
0 |
|
COMPLETE TESTING - 15500/- |
| 4.2, Table No.1 , 1) , iv)(Colour in ICUMSA units, Max) |
- |
0 |
|
COMPLETE TESTING - 15500/- |
| 4.2, Table No.1 , 1) , v)(Conductivity ash, percent by mass, Max) |
- |
0 |
|
COMPLETE TESTING - 15500/- |
| 4.2, Table No.1 , 1) , vi)(Sulphur dioxide, mg/kg, Max) |
- |
0 |
|
COMPLETE TESTING - 15500/- |
| 4.2, Table No.1 , 1) , vii)(Lead, mg/kg, Max) |
- |
0 |
|
COMPLETE TESTING - 15500/- |
| 4.2, Table No.1 , 1) , viii)(Chromium, µg/mg, Max) |
- |
0 |
|
COMPLETE TESTING - 15500/- |
| 4.2, Table No.1 , 1) , ix)(Sediment mg/kg Max) |
- |
0 |
|
COMPLETE TESTING - 15500/- |
| 4.2, Table No.1 , 1) , x)(Iron mg/kg Max) |
- |
0 |
|
COMPLETE TESTING - 15500/- |
| 4.2, Table No.1 , 1) , xi)(Floc test) |
- |
0 |
|
COMPLETE TESTING - 15500/- |
| 4.1(Description) |
- |
0 |
|
COMPLETE TESTING - 15500/- |
| 4.2, Table No.1 , 1) , i)(Loss on drying percent by mass, Max) |
- |
0 |
|
COMPLETE TESTING - 15500/- |
| 4.2, Table No.1 , 1) , ii)(Reducing sugar, percent by mass, Max) |
- |
0 |
|
COMPLETE TESTING - 15500/- |
| 4.2, Table No.1 , 1) , ii)(Polarization, °Z, Min,) |
- |
0 |
|
COMPLETE TESTING - 15500/- |
| 4.2, Table No.1 , 1) , iv)(Reducing sugar, percent by mass, Max) |
- |
0 |
|
COMPLETE TESTING - 15500/- |
| 4.2, Table No.1 , 1) , iii)(Reducing sugar, percent by mass, Max) |
- |
0 |
|
COMPLETE TESTING - 15500/- |
| 4.2, Table No.1 , 1) , iv)(Colour in ICUMSA units, Max) |
- |
0 |
|
COMPLETE TESTING - 15500/- |
| 4.2, Table No.1 , 1) , v)(Conductivity ash, percent by mass, Max) |
- |
0 |
|
COMPLETE TESTING - 15500/- |
| 4.2, Table No.1 , 1) , vi)(Sulphur dioxide, mg/kg, Max) |
- |
0 |
|
COMPLETE TESTING - 15500/- |
| 4.2, Table No.1 , 1) , vii)(Lead, mg/kg, Max) |
- |
0 |
|
COMPLETE TESTING - 15500/- |
| 4.2, Table No.1 , 1) , viii)(Chromium, µg/mg, Max) |
- |
0 |
|
COMPLETE TESTING - 15500/- |
| 4.2, Table No.1 , 1) , ix)(Sediment mg/kg Max) |
- |
0 |
|
COMPLETE TESTING - 15500/- |
| 4.2, Table No.1 , 1) , x)(Iron mg/kg Max) |
- |
0 |
|
COMPLETE TESTING - 15500/- |
| 4.2, Table No.1 , 1) , xi)(Floc test) |
- |
0 |
|
COMPLETE TESTING - 15500/- |
| 4.1(Description) |
- |
0 |
|
COMPLETE TESTING - 15500/- |
| 4.2, Table No.1 , 1) , i)(Loss on drying percent by mass, Max) |
- |
0 |
|
COMPLETE TESTING - 15500/- |
| 4.2, Table No.1 , 1) , ii)(Reducing sugar, percent by mass, Max) |
- |
0 |
|
COMPLETE TESTING - 15500/- |
| 4.2, Table No.1 , 1) , ii)(Polarization, °Z, Min,) |
- |
0 |
|
COMPLETE TESTING - 15500/- |
| 4.2, Table No.1 , 1) , iv)(Reducing sugar, percent by mass, Max) |
- |
0 |
|
COMPLETE TESTING - 15500/- |
| 4.2, Table No.1 , 1) , iii)(Reducing sugar, percent by mass, Max) |
- |
0 |
|
COMPLETE TESTING - 15500/- |
| 4.2, Table No.1 , 1) , iv)(Colour in ICUMSA units, Max) |
- |
0 |
|
COMPLETE TESTING - 15500/- |
| 4.2, Table No.1 , 1) , v)(Conductivity ash, percent by mass, Max) |
- |
0 |
|
COMPLETE TESTING - 15500/- |
| 4.2, Table No.1 , 1) , vi)(Sulphur dioxide, mg/kg, Max) |
- |
0 |
|
COMPLETE TESTING - 15500/- |
| 4.2, Table No.1 , 1) , vii)(Lead, mg/kg, Max) |
- |
0 |
|
COMPLETE TESTING - 15500/- |
| 4.2, Table No.1 , 1) , viii)(Chromium, µg/mg, Max) |
- |
0 |
|
COMPLETE TESTING - 15500/- |
| 4.2, Table No.1 , 1) , ix)(Sediment mg/kg Max) |
- |
0 |
|
COMPLETE TESTING - 15500/- |
| 4.2, Table No.1 , 1) , x)(Iron mg/kg Max) |
- |
0 |
|
COMPLETE TESTING - 15500/- |
| 4.2, Table No.1 , 1) , xi)(Floc test) |
- |
3000 |
|
COMPLETE TESTING - 15500/- |
| 4.1(Description) |
- |
- |
|
- |
| 4.2, Table No.1 , 1) , i)(Loss on drying percent by mass, Max) |
- |
- |
|
- |
| 4.2, Table No.1 , 1) , ii)(Reducing sugar, percent by mass, Max) |
- |
- |
|
- |
| 4.2, Table No.1 , 1) , ii)(Polarization, °Z, Min,) |
- |
- |
|
- |
| 4.2, Table No.1 , 1) , iv)(Reducing sugar, percent by mass, Max) |
- |
- |
|
- |
| 4.2, Table No.1 , 1) , iii)(Reducing sugar, percent by mass, Max) |
- |
- |
|
- |
| 4.2, Table No.1 , 1) , iv)(Colour in ICUMSA units, Max) |
- |
- |
|
- |
| 4.2, Table No.1 , 1) , v)(Conductivity ash, percent by mass, Max) |
- |
- |
|
- |
| 4.2, Table No.1 , 1) , vi)(Sulphur dioxide, mg/kg, Max) |
- |
- |
|
- |
| 4.2, Table No.1 , 1) , vii)(Lead, mg/kg, Max) |
- |
- |
|
- |
| 4.2, Table No.1 , 1) , viii)(Chromium, µg/mg, Max) |
- |
- |
|
- |
| 4.2, Table No.1 , 1) , ix)(Sediment mg/kg Max) |
- |
- |
|
- |
| 4.2, Table No.1 , 1) , x)(Iron mg/kg Max) |
- |
- |
|
- |
| 4.2, Table No.1 , 1) , xi)(Floc test) |
- |
- |
|
- |
|
17 Jun, 2027 |
- Included.w.e.f.15.01.2025 |
| 7476 |
Classic Testing & Research Centre (B17), Noida
| 8180826
| IS 302 : Part 2 : Sec 4 (1993) |
Safety of household and similar electrical appliances: Part 2 particular requirements: Sec 4 spin extractors |
- |
60000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 3(GENERAL REQUIREMENTS) |
- |
1000 |
|
20% Discount to BIS |
| 4(GENERAL NOTES ON TESTS) |
- |
1000 |
|
20% Discount to BIS |
| 5(RATING) |
- |
1000 |
|
20% Discount to BIS |
| 6(CLASSIFICATION) |
- |
1000 |
|
20% Discount to BIS |
| 7(MARKING) |
- |
1000 |
|
20% Discount to BIS |
| 8(PROTECTION AGAINST ELECTRIC SHOCK) |
- |
2000 |
|
20% Discount to BIS |
| 9(STARTING OF MOTOR-OPERATED APPLIANCES) |
- |
2000 |
|
20% Discount to BIS |
| 10(INPUT AND CURRENT) |
- |
2000 |
|
20% Discount to BIS |
| 11(HEATING) |
- |
2000 |
|
20% Discount to BIS |
| 13(ELECTRICAL INSULATION AND LEAKAGE CURRENT AT OPERATING TEMPERATURE) |
- |
2000 |
|
20% Discount to BIS |
| 14(RADIO AND TELEVISION INTERFERENCE SUPPRESSION) |
- |
2000 |
|
20% Discount to BIS |
| 15(MOISTURE RESISTANCE) |
- |
2000 |
|
20% Discount to BIS |
| 16(INSULATION RESISTANCE AND ELECTRIC STRENGTH (AFTER HUMIDITY TREATMENT)) |
- |
2000 |
|
20% Discount to BIS |
| 17(OVERLOAD PROTECTION) |
- |
2000 |
|
20% Discount to BIS |
| 19(ABNORMAL OPERATION) |
- |
2000 |
|
20% Discount to BIS |
| 20(STABILITY AND MECHANICAL HAZARDS) |
- |
2000 |
|
20% Discount to BIS |
| 21(MECHANICAL STRENGTH) |
- |
2000 |
|
20% Discount to BIS |
| 22(CONSTRUCTION) |
- |
2000 |
|
20% Discount to BIS |
| 23(INTERNAL WIRING) |
- |
2000 |
|
20% Discount to BIS |
| 24(COMPONENTS) |
- |
2000 |
|
20% Discount to BIS |
| 25(SUPPLY CONNECTION AND EXTERNAL FLEXIBLE CABLES AND CORDS) |
- |
2000 |
|
20% Discount to BIS |
| 26(TERMINALS FOR EXTERNAL CONDUCTORS) |
- |
2000 |
|
20% Discount to BIS |
| 27(PROVISION FOR EARTHING) |
- |
2000 |
|
20% Discount to BIS |
| 28(SCREWS AND CONNECTIONS) |
- |
2000 |
|
20% Discount to BIS |
| 29(CREEPAGE DISTANCES, CLEARANCES AND DISTANCES THROUGH INSULATION) |
- |
2000 |
|
20% Discount to BIS |
| 30(RESISTANCE TO HEAT, FIRE AND TRACKING) |
- |
2000 |
|
20% Discount to BIS |
| 31(RESISTANCE TO RUSTING) |
- |
2000 |
|
20% Discount to BIS |
| 19.11.4.1(Electrostatic discharges) |
- |
2000 |
|
20% Discount to BIS |
| 19.11.4.3(Fast transient bursts) |
- |
2000 |
|
20% Discount to BIS |
| 19.11.4.4(Surge immunity test) |
- |
2000 |
|
20% Discount to BIS |
| 19.11.4.6(Class 3 Voltage dips and interruptions) |
- |
2000 |
|
20% Discount to BIS |
| 19.11.4.7(Harmonics) |
- |
2000 |
|
20% Discount to BIS |
|
15 Oct, 2027 |
- Included w.e.f.12.12.2024 Exclusion Cl 19.11.4.2 (Radiated fields) CL 19.11.4.5 (Immunity to conducted discharges) |
| 7477 |
Gravitas Laboratories Private Limited, Greater Noida
| 8182606
| IS 15997 (2012) |
Low nickel austenitic stainless steel sheet and strip for utensils and kitchen appliances - Specification |
- |
10000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl. 8.1, 8.1.1 & 10.1 Table 1(Carbon -IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
250 |
|
- |
| Cl. 8.1, 8.1.1 & 10.1 Table 1(Silicon -IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
250 |
|
- |
| Cl. 8.1, 8.1.1 & 10.1 Table 1(Manganese -IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
250 |
|
- |
| Cl. 8.1, 8.1.1 & 10.1 Table 1(Nickel -IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
250 |
|
- |
| Cl. 8.1, 8.1.1 & 10.1 Table 1(Chromium -IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
250 |
|
- |
| Cl. 8.1, 8.1.1 & 10.1 Table 1(Sulphur -IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
250 |
|
- |
| Cl. 8.1, 8.1.1 & 10.1 Table 1(Phosphorus -IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
250 |
|
- |
| Cl. 8.1, 8.1.1 & 10.1 Table 1(Copper -IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
250 |
|
- |
| Cl. 8.1, 8.1.1 & 10.1 Table 1(Nitrogen -IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
250 |
|
- |
| 6(Freedom From Defects) |
- |
500 |
|
- |
| 9.3(Tensile Test-1608:Part 1) |
- |
1000 |
|
- |
| 9.3, Table 3 (Yield Strength, Mpa) |
- |
800 |
|
- |
| 9.3, Table 3 (Tensile Strength, Mpa) |
- |
1000 |
|
- |
| 9.3, Table 3 (Elongation, %) |
- |
800 |
|
- |
| 9.4(Erichsen Cupping Test,(Average depth of cupping) mm) |
- |
900 |
|
- |
| 11(Surface finish) |
- |
0 |
|
- |
| 12(Dimensions) |
- |
500 |
|
- |
| 14.1(Thickness,mm) |
- |
280 |
|
- |
| 14.2( Width, mm) |
- |
250 |
|
- |
| 14.3(Length, mm) |
- |
250 |
|
- |
| 14.4(Flatness, mm) |
- |
350 |
|
- |
| 14.5(Camber, mm) |
- |
350 |
|
- |
| Clause 9.1, 9.2 & Table 3(IS 1608 Part 1) |
- |
1000 |
|
- |
| 17(Marking) |
- |
0 |
|
- |
| Clause 9.1, 9.2 & Table 3(0.2 Percent Yield Strength) |
- |
800 |
|
- |
| 4.1(General requirements) |
- |
0 |
|
- |
| 6(Freedom from defects) |
- |
500 |
|
- |
| 7(Heat treatment) |
- |
0 |
|
- |
| 8.1, table 1(C
Si
Mn
Ni
Cr
S
P
Cu
Ni) |
- |
700 |
|
- |
| 8.1.1, table 2(Carbon
Silicon
Manganese
Nickel
Chromium
Sulphur
Phosphorus
Copper
Nitrogen) |
- |
900 |
|
- |
| 9.1(Sample plan) |
- |
0 |
|
- |
| 9.2(Tensile test) |
- |
1000 |
|
- |
| 9.3(Mechanical properties) |
- |
1250 |
|
- |
| 9.4(Erichsen cupping test) |
- |
800 |
|
- |
| 10(Retests) |
- |
1000 |
|
- |
| 11(Surface finish) |
- |
0 |
|
- |
| 12(Dimensions) |
- |
750 |
|
- |
| 13(Edge condition) |
- |
0 |
|
- |
| 14.1(Thickness) |
- |
250 |
|
- |
| 14.2.1(Mill Edge) |
- |
250 |
|
- |
| 14.2.2(Trimmed Edge) |
- |
250 |
|
- |
| 14.3(Length) |
- |
250 |
|
- |
| 14.4(Flatness) |
- |
300 |
|
- |
| 14.5(Camber) |
- |
300 |
|
- |
| 15(Inspection) |
- |
0 |
|
- |
| 17(Marking) |
- |
0 |
|
- |
| Cl. 8.1, 8.1.1 & 10.1 Table 1(Carbon -IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
300 |
|
- |
| Cl. 8.1, 8.1.1 & 10.1 Table 1(Silicon -IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
300 |
|
- |
| Cl. 8.1, 8.1.1 & 10.1 Table 1(Manganese -IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
300 |
|
- |
| Cl. 8.1, 8.1.1 & 10.1 Table 1(Nickel -IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
300 |
|
- |
| Cl. 8.1, 8.1.1 & 10.1 Table 1(Chromium -IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
300 |
|
- |
| Cl. 8.1, 8.1.1 & 10.1 Table 1(Sulphur -IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
300 |
|
- |
| Cl. 8.1, 8.1.1 & 10.1 Table 1(Phosphorus -IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
300 |
|
- |
| Cl. 8.1, 8.1.1 & 10.1 Table 1(Copper -IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
300 |
|
- |
| Cl. 8.1, 8.1.1 & 10.1 Table 1(Nitrogen -IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
300 |
|
- |
| 6(Freedom From Defects) |
- |
250 |
|
- |
| 9.3(Tensile Test-1608:Part 1) |
- |
1200 |
|
- |
| 9.3, Table 3 (Yield Strength, Mpa) |
- |
1000 |
|
- |
| 9.3, Table 3 (Tensile Strength, Mpa) |
- |
1000 |
|
- |
| 9.3, Table 3 (Elongation, %) |
- |
1000 |
|
- |
| 9.4(Erichsen Cupping Test,(Average depth of cupping) mm) |
- |
1200 |
|
- |
| 11(Surface finish) |
- |
650 |
|
- |
| 12(Dimensions) |
- |
500 |
|
- |
| 14.1(Thickness,mm) |
- |
250 |
|
- |
| 14.2( Width, mm) |
- |
250 |
|
- |
| 14.3(Length, mm) |
- |
250 |
|
- |
| 14.4(Flatness, mm) |
- |
25 |
|
- |
| 14.5(Camber, mm) |
- |
250 |
|
- |
| Clause 9.1, 9.2 & Table 3(IS 1608 Part 1) |
- |
250 |
|
- |
| 17(Marking) |
- |
0 |
|
- |
| Clause 9.1, 9.2 & Table 3(0.2 Percent Yield Strength) |
- |
1200 |
|
- |
| 4.1(General requirements) |
- |
0 |
|
- |
| 6(Freedom from defects) |
- |
500 |
|
- |
| 7(Heat treatment) |
- |
0 |
|
- |
| 8.1, table 1(C
Si
Mn
Ni
Cr
S
P
Cu
Ni) |
- |
1100 |
|
- |
| 8.1.1, table 2(Carbon
Silicon
Manganese
Nickel
Chromium
Sulphur
Phosphorus
Copper
Nitrogen) |
- |
500 |
|
- |
| 9.1(Sample plan) |
- |
0 |
|
- |
| 9.2(Tensile test) |
- |
1200 |
|
- |
| 9.3(Mechanical properties) |
- |
1200 |
|
- |
| 9.4(Erichsen cupping test) |
- |
1200 |
|
- |
| 10(Retests) |
- |
1500 |
|
- |
| 11(Surface finish) |
- |
300 |
|
- |
| 12(Dimensions) |
- |
300 |
|
- |
| 13(Edge condition) |
- |
0 |
|
- |
| 14.1(Thickness) |
- |
250 |
|
- |
| 14.2.1(Mill Edge) |
- |
250 |
|
- |
| 14.2.2(Trimmed Edge) |
- |
250 |
|
- |
| 14.3(Length) |
- |
250 |
|
- |
| 14.4(Flatness) |
- |
250 |
|
- |
| 14.5(Camber) |
- |
250 |
|
- |
| 15(Inspection) |
- |
0 |
|
- |
| 17(Marking) |
- |
0 |
|
- |
| Cl. 8.1, 8.1.1 & 10.1 Table 1(Carbon -IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
0 |
|
- |
| Cl. 8.1, 8.1.1 & 10.1 Table 1(Silicon -IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
0 |
|
- |
| Cl. 8.1, 8.1.1 & 10.1 Table 1(Manganese -IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
0 |
|
- |
| Cl. 8.1, 8.1.1 & 10.1 Table 1(Nickel -IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
0 |
|
- |
| Cl. 8.1, 8.1.1 & 10.1 Table 1(Chromium -IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
0 |
|
- |
| Cl. 8.1, 8.1.1 & 10.1 Table 1(Sulphur -IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
0 |
|
- |
| Cl. 8.1, 8.1.1 & 10.1 Table 1(Phosphorus -IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
0 |
|
- |
| Cl. 8.1, 8.1.1 & 10.1 Table 1(Copper -IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
0 |
|
- |
| Cl. 8.1, 8.1.1 & 10.1 Table 1(Nitrogen -IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
0 |
|
- |
| 6(Freedom From Defects) |
- |
0 |
|
- |
| 9.3(Tensile Test-1608:Part 1) |
- |
0 |
|
- |
| 9.3, Table 3 (Yield Strength, Mpa) |
- |
0 |
|
- |
| 9.3, Table 3 (Tensile Strength, Mpa) |
- |
0 |
|
- |
| 9.3, Table 3 (Elongation, %) |
- |
0 |
|
- |
| 9.4(Erichsen Cupping Test,(Average depth of cupping) mm) |
- |
0 |
|
- |
| 11(Surface finish) |
- |
0 |
|
- |
| 12(Dimensions) |
- |
0 |
|
- |
| 14.1(Thickness,mm) |
- |
0 |
|
- |
| 14.2( Width, mm) |
- |
0 |
|
- |
| 14.3(Length, mm) |
- |
0 |
|
- |
| 14.4(Flatness, mm) |
- |
0 |
|
- |
| 14.5(Camber, mm) |
- |
0 |
|
- |
| Clause 9.1, 9.2 & Table 3(IS 1608 Part 1) |
- |
0 |
|
- |
| 17(Marking) |
- |
0 |
|
- |
| Clause 9.1, 9.2 & Table 3(0.2 Percent Yield Strength) |
- |
0 |
|
- |
| 4.1(General requirements) |
- |
0 |
|
- |
| 6(Freedom from defects) |
- |
0 |
|
- |
| 7(Heat treatment) |
- |
0 |
|
- |
| 8.1, table 1(C
Si
Mn
Ni
Cr
S
P
Cu
Ni) |
- |
0 |
|
- |
| 8.1.1, table 2(Carbon
Silicon
Manganese
Nickel
Chromium
Sulphur
Phosphorus
Copper
Nitrogen) |
- |
0 |
|
- |
| 9.1(Sample plan) |
- |
0 |
|
- |
| 9.2(Tensile test) |
- |
0 |
|
- |
| 9.3(Mechanical properties) |
- |
0 |
|
- |
| 9.4(Erichsen cupping test) |
- |
0 |
|
- |
| 10(Retests) |
- |
0 |
|
- |
| 11(Surface finish) |
- |
0 |
|
- |
| 12(Dimensions) |
- |
0 |
|
- |
| 13(Edge condition) |
- |
0 |
|
- |
| 14.1(Thickness) |
- |
0 |
|
- |
| 14.2.1(Mill Edge) |
- |
0 |
|
- |
| 14.2.2(Trimmed Edge) |
- |
0 |
|
- |
| 14.3(Length) |
- |
0 |
|
- |
| 14.4(Flatness) |
- |
0 |
|
- |
| 14.5(Camber) |
- |
0 |
|
- |
| 15(Inspection) |
- |
0 |
|
- |
| 17(Marking) |
- |
0 |
|
- |
|
- |
- Included w.e.f 16.05.2025 |
| 7478 |
Gravitas Laboratories Private Limited, Greater Noida
| 8182606
| IS 737 (2024) |
WROUGHT ALUMINIUM AND ALUMINIUM ALLOY SHEET AND STRIP FOR GENERAL ENGINEERING PURPOSES SPECIFICATION (Fifth Revision) |
- |
13500 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl. 4(Ordering Information - IS 737) |
- |
0 |
|
- |
| Cl. 4 (a)(Grade/ Thickness - IS 737) |
- |
0 |
|
- |
| Cl. 4 (b)(Condition - IS 737) |
- |
0 |
|
- |
| Cl. 4 (c)(Quantity in Kg - IS 737) |
- |
0 |
|
- |
| Cl. 4 (d)(Size - Thickness X Width X Length (T X W X L) in mm for sheets and (T X W) in mm for Strips/ Coils - IS 737) |
- |
0 |
|
- |
| Cl. 4 (e)(Coil ID and Coil Weight for Strips/ Coils - IS 737) |
- |
0 |
|
- |
| Cl. 4 (f)(Core/ Spool Requirement for Coils - IS 737) |
- |
0 |
|
- |
| Cl. 4 (g)(Packing Mode - IS 737) |
- |
0 |
|
- |
| Cl. 5(Supply for Material - IS 737/ IS 10259) |
- |
0 |
|
- |
| Cl. 6(Freedom from Defects - IS 737) |
- |
600 |
|
- |
| Cl. 7(Chemical Composition - IS 504/ IS 504 (Part-1 to 12)/ IS 504 (Part-13 to 16)/ ASTM E 1251/ IS 11035) |
- |
350 |
|
- |
| Cl. 7(Si - IS 504 (Part-1)/ ASTM E 1251/ IS 11035) |
- |
350 |
|
- |
| Cl. 7(Fe - IS 504 (Part-2)/ ASTM E 1251/ IS 11035) |
- |
350 |
|
- |
| Cl. 7(Cu - IS 504 (Part-3)/ ASTM E 1251/ IS 11035) |
- |
300 |
|
- |
| Cl. 7(Mn - IS 504 (Part-5)/ ASTM E 1251/ IS 11035) |
- |
350 |
|
- |
| Cl. 7(Mg - IS 504 (Part-6)/ ASTM E 1251/ IS 11035) |
- |
350 |
|
- |
| Cl. 7(Cr - IS 504 (Part-8)/ ASTM E 1251/ IS 11035) |
- |
300 |
|
- |
| Cl. 7(Zn - IS 504 (Part-4)/ ASTM E 1251/ IS 11035) |
- |
350 |
|
- |
| Cl. 7(Ti - IS 504 (Part-11)/ ASTM E 1251/ IS 11035) |
- |
350 |
|
- |
| Cl. 7(Others (Each) - IS 504/ IS 504 (Part-1 to 12)/ IS 504 (Part-13 to 16)/ ASTM E 1251/ IS 11035) |
- |
800 |
|
- |
| Cl. 7(Others (Total) - IS 504/ IS 504 (Part-1 to 12)/ IS 504 (Part-13 to 16)/ ASTM E 1251/ IS 11035) |
- |
800 |
|
- |
| Cl. 7(Al - IS 504) |
- |
400 |
|
- |
| Cl. 8(Mechanical Properties - IS 1608 (Part-1)) |
- |
1250 |
|
- |
| Cl. 8.1(0.2% Proof Stress - IS 1608 (Part-1)) |
- |
800 |
|
- |
| Cl. 8.1(Tensile Strength - IS 1608 (Part-1)) |
- |
1250 |
|
- |
| Cl. 8.1(Elongation on 50mm Gauge Length - IS 1608 (Part-1)) |
- |
800 |
|
- |
| Cl. 8.2(Bend Test - IS 1599) |
- |
900 |
|
- |
| Cl. 9(Condition - IS 737/ IS 5052) |
- |
0 |
|
- |
| Cl. 10(Dimensions and Tolerances - IS 737/ IS 2676) |
- |
700 |
|
- |
| Cl. 11(Selection of Test Samples - IS 737) |
- |
0 |
|
- |
| Cl. 11.1(Sheet and Strip of Aluminium or Non - Heat Treatable Aluminium Alloy - IS 737) |
- |
0 |
|
- |
| Cl. 11.2(Sheet and Strip of Heat - Treatable Aluminium Alloys - IS 737) |
- |
0 |
|
- |
| Cl. 12(Retests - IS 737/ IS 10259) |
- |
1200 |
|
- |
| Cl. 13(Packaging - IS 737/ IS 10259) |
- |
0 |
|
- |
| Cl. 13.1(Marking - IS 737) |
- |
0 |
|
- |
| Cl. 4(Ordering Information - IS 737) |
- |
0 |
|
- |
| Cl. 4 (a)(Grade/ Thickness - IS 737) |
- |
0 |
|
- |
| Cl. 4 (b)(Condition - IS 737) |
- |
0 |
|
- |
| Cl. 4 (c)(Quantity in Kg - IS 737) |
- |
0 |
|
- |
| Cl. 4 (d)(Size - Thickness X Width X Length (T X W X L) in mm for sheets and (T X W) in mm for Strips/ Coils - IS 737) |
- |
0 |
|
- |
| Cl. 4 (e)(Coil ID and Coil Weight for Strips/ Coils - IS 737) |
- |
0 |
|
- |
| Cl. 4 (f)(Core/ Spool Requirement for Coils - IS 737) |
- |
0 |
|
- |
| Cl. 4 (g)(Packing Mode - IS 737) |
- |
0 |
|
- |
| Cl. 5(Supply for Material - IS 737/ IS 10259) |
- |
0 |
|
- |
| Cl. 6(Freedom from Defects - IS 737) |
- |
500 |
|
- |
| Cl. 7(Chemical Composition - IS 504/ IS 504 (Part-1 to 12)/ IS 504 (Part-13 to 16)/ ASTM E 1251/ IS 11035) |
- |
500 |
|
- |
| Cl. 7(Si - IS 504 (Part-1)/ ASTM E 1251/ IS 11035) |
- |
500 |
|
- |
| Cl. 7(Fe - IS 504 (Part-2)/ ASTM E 1251/ IS 11035) |
- |
500 |
|
- |
| Cl. 7(Cu - IS 504 (Part-3)/ ASTM E 1251/ IS 11035) |
- |
500 |
|
- |
| Cl. 7(Mn - IS 504 (Part-5)/ ASTM E 1251/ IS 11035) |
- |
500 |
|
- |
| Cl. 7(Mg - IS 504 (Part-6)/ ASTM E 1251/ IS 11035) |
- |
500 |
|
- |
| Cl. 7(Cr - IS 504 (Part-8)/ ASTM E 1251/ IS 11035) |
- |
500 |
|
- |
| Cl. 7(Zn - IS 504 (Part-4)/ ASTM E 1251/ IS 11035) |
- |
500 |
|
- |
| Cl. 7(Ti - IS 504 (Part-11)/ ASTM E 1251/ IS 11035) |
- |
500 |
|
- |
| Cl. 7(Others (Each) - IS 504/ IS 504 (Part-1 to 12)/ IS 504 (Part-13 to 16)/ ASTM E 1251/ IS 11035) |
- |
500 |
|
- |
| Cl. 7(Others (Total) - IS 504/ IS 504 (Part-1 to 12)/ IS 504 (Part-13 to 16)/ ASTM E 1251/ IS 11035) |
- |
500 |
|
- |
| Cl. 7(Al - IS 504) |
- |
500 |
|
- |
| Cl. 8(Mechanical Properties - IS 1608 (Part-1)) |
- |
1000 |
|
- |
| Cl. 8.1(0.2% Proof Stress - IS 1608 (Part-1)) |
- |
1000 |
|
- |
| Cl. 8.1(Tensile Strength - IS 1608 (Part-1)) |
- |
1000 |
|
- |
| Cl. 8.1(Elongation on 50mm Gauge Length - IS 1608 (Part-1)) |
- |
1000 |
|
- |
| Cl. 8.2(Bend Test - IS 1599) |
- |
1000 |
|
- |
| Cl. 9(Condition - IS 737/ IS 5052) |
- |
0 |
|
- |
| Cl. 10(Dimensions and Tolerances - IS 737/ IS 2676) |
- |
1000 |
|
- |
| Cl. 11(Selection of Test Samples - IS 737) |
- |
0 |
|
- |
| Cl. 11.1(Sheet and Strip of Aluminium or Non - Heat Treatable Aluminium Alloy - IS 737) |
- |
0 |
|
- |
| Cl. 11.2(Sheet and Strip of Heat - Treatable Aluminium Alloys - IS 737) |
- |
0 |
|
- |
| Cl. 12(Retests - IS 737/ IS 10259) |
- |
2000 |
|
- |
| Cl. 13(Packaging - IS 737/ IS 10259) |
- |
0 |
|
- |
| Cl. 13.1(Marking - IS 737) |
- |
0 |
|
- |
| Cl. 4(Ordering Information - IS 737) |
- |
0 |
|
- |
| Cl. 4 (a)(Grade/ Thickness - IS 737) |
- |
0 |
|
- |
| Cl. 4 (b)(Condition - IS 737) |
- |
0 |
|
- |
| Cl. 4 (c)(Quantity in Kg - IS 737) |
- |
0 |
|
- |
| Cl. 4 (d)(Size - Thickness X Width X Length (T X W X L) in mm for sheets and (T X W) in mm for Strips/ Coils - IS 737) |
- |
0 |
|
- |
| Cl. 4 (e)(Coil ID and Coil Weight for Strips/ Coils - IS 737) |
- |
0 |
|
- |
| Cl. 4 (f)(Core/ Spool Requirement for Coils - IS 737) |
- |
0 |
|
- |
| Cl. 4 (g)(Packing Mode - IS 737) |
- |
0 |
|
- |
| Cl. 6(Freedom from Defects - IS 737) |
- |
500 |
|
- |
| Cl. 7(Chemical Composition - IS 504/ IS 504 (Part-1 to 12)/ IS 504 (Part-13 to 16)/ ASTM E 1251/ IS 11035) |
- |
500 |
|
- |
| Cl. 7(Si - IS 504 (Part-1)/ ASTM E 1251/ IS 11035) |
- |
500 |
|
- |
| Cl. 7(Fe - IS 504 (Part-2)/ ASTM E 1251/ IS 11035) |
- |
500 |
|
- |
| Cl. 7(Cu - IS 504 (Part-3)/ ASTM E 1251/ IS 11035) |
- |
500 |
|
- |
| Cl. 7(Mn - IS 504 (Part-5)/ ASTM E 1251/ IS 11035) |
- |
500 |
|
- |
| Cl. 7(Mg - IS 504 (Part-6)/ ASTM E 1251/ IS 11035) |
- |
500 |
|
- |
| Cl. 7(Cr - IS 504 (Part-8)/ ASTM E 1251/ IS 11035) |
- |
500 |
|
- |
| Cl. 7(Zn - IS 504 (Part-4)/ ASTM E 1251/ IS 11035) |
- |
500 |
|
- |
| Cl. 7(Ti - IS 504 (Part-11)/ ASTM E 1251/ IS 11035) |
- |
500 |
|
- |
| Cl. 7(Others (Each) - IS 504/ IS 504 (Part-1 to 12)/ IS 504 (Part-13 to 16)/ ASTM E 1251/ IS 11035) |
- |
500 |
|
- |
| Cl. 7(Others (Total) - IS 504/ IS 504 (Part-1 to 12)/ IS 504 (Part-13 to 16)/ ASTM E 1251/ IS 11035) |
- |
500 |
|
- |
| Cl. 7(Al - IS 504) |
- |
500 |
|
- |
| Cl. 8(Mechanical Properties - IS 1608 (Part-1)) |
- |
1000 |
|
- |
| Cl. 8.1(0.2% Proof Stress - IS 1608 (Part-1)) |
- |
1000 |
|
- |
| Cl. 8.1(Tensile Strength - IS 1608 (Part-1)) |
- |
1000 |
|
- |
| Cl. 8.1(Elongation on 50mm Gauge Length - IS 1608 (Part-1)) |
- |
1000 |
|
- |
| Cl. 8.2(Bend Test - IS 1599) |
- |
1000 |
|
- |
| Cl. 9(Condition - IS 737/ IS 5052) |
- |
0 |
|
- |
| Cl. 10(Dimensions and Tolerances - IS 737/ IS 2676) |
- |
1000 |
|
- |
| Cl. 11(Selection of Test Samples - IS 737) |
- |
0 |
|
- |
| Cl. 11.1(Sheet and Strip of Aluminium or Non - Heat Treatable Aluminium Alloy - IS 737) |
- |
0 |
|
- |
| Cl. 11.2(Sheet and Strip of Heat - Treatable Aluminium Alloys - IS 737) |
- |
0 |
|
- |
| Cl. 12(Retests - IS 737/ IS 10259) |
- |
2000 |
|
- |
| Cl. 13(Packaging - IS 737/ IS 10259) |
- |
0 |
|
- |
| Cl. 13.1(Marking - IS 737) |
- |
0 |
|
- |
| Cl. 4(Ordering Information - IS 737) |
- |
500 |
|
- |
| Cl. 4 (a)(Grade/ Thickness - IS 737) |
- |
500 |
|
- |
| Cl. 4 (b)(Condition - IS 737) |
- |
500 |
|
- |
| Cl. 4 (c)(Quantity in Kg - IS 737) |
- |
500 |
|
- |
| Cl. 4 (d)(Size - Thickness X Width X Length (T X W X L) in mm for sheets and (T X W) in mm for Strips/ Coils - IS 737) |
- |
500 |
|
- |
| Cl. 4 (e)(Coil ID and Coil Weight for Strips/ Coils - IS 737) |
- |
500 |
|
- |
| Cl. 4 (f)(Core/ Spool Requirement for Coils - IS 737) |
- |
500 |
|
- |
| Cl. 4 (g)(Packing Mode - IS 737) |
- |
500 |
|
- |
| Cl. 6(Freedom from Defects - IS 737) |
- |
500 |
|
- |
| Cl. 7(Chemical Composition - IS 504/ IS 504 (Part-1 to 12)/ IS 504 (Part-13 to 16)/ ASTM E 1251/ IS 11035) |
- |
500 |
|
- |
| Cl. 7(Si - IS 504 (Part-1)/ ASTM E 1251/ IS 11035) |
- |
500 |
|
- |
| Cl. 7(Fe - IS 504 (Part-2)/ ASTM E 1251/ IS 11035) |
- |
500 |
|
- |
| Cl. 7(Cu - IS 504 (Part-3)/ ASTM E 1251/ IS 11035) |
- |
500 |
|
- |
| Cl. 7(Mn - IS 504 (Part-5)/ ASTM E 1251/ IS 11035) |
- |
500 |
|
- |
| Cl. 7(Mg - IS 504 (Part-6)/ ASTM E 1251/ IS 11035) |
- |
500 |
|
- |
| Cl. 7(Cr - IS 504 (Part-8)/ ASTM E 1251/ IS 11035) |
- |
500 |
|
- |
| Cl. 7(Zn - IS 504 (Part-4)/ ASTM E 1251/ IS 11035) |
- |
500 |
|
- |
| Cl. 7(Ti - IS 504 (Part-11)/ ASTM E 1251/ IS 11035) |
- |
500 |
|
- |
| Cl. 7(Others (Each) - IS 504/ IS 504 (Part-1 to 12)/ IS 504 (Part-13 to 16)/ ASTM E 1251/ IS 11035) |
- |
500 |
|
- |
| Cl. 7(Others (Total) - IS 504/ IS 504 (Part-1 to 12)/ IS 504 (Part-13 to 16)/ ASTM E 1251/ IS 11035) |
- |
500 |
|
- |
| Cl. 7(Al - IS 504) |
- |
500 |
|
- |
| Cl. 8(Mechanical Properties - IS 1608 (Part-1)) |
- |
500 |
|
- |
| Cl. 8.1(0.2% Proof Stress - IS 1608 (Part-1)) |
- |
500 |
|
- |
| Cl. 8.1(Tensile Strength - IS 1608 (Part-1)) |
- |
500 |
|
- |
| Cl. 8.1(Elongation on 50mm Gauge Length - IS 1608 (Part-1)) |
- |
500 |
|
- |
| Cl. 8.2(Bend Test - IS 1599) |
- |
500 |
|
- |
| Cl. 9(Condition - IS 737/ IS 5052) |
- |
500 |
|
- |
| Cl. 10(Dimensions and Tolerances - IS 737/ IS 2676) |
- |
500 |
|
- |
| Cl. 11(Selection of Test Samples - IS 737) |
- |
500 |
|
- |
| Cl. 11.1(Sheet and Strip of Aluminium or Non - Heat Treatable Aluminium Alloy - IS 737) |
- |
500 |
|
- |
| Cl. 11.2(Sheet and Strip of Heat - Treatable Aluminium Alloys - IS 737) |
- |
500 |
|
- |
| Cl. 12(Retests - IS 737/ IS 10259) |
- |
500 |
|
- |
| Cl. 13(Packaging - IS 737/ IS 10259) |
- |
500 |
|
- |
| Cl. 13.1(Marking - IS 737) |
- |
500 |
|
- |
|
- |
- Included w.e.f. 18.02.2025 |
| 7479 |
Gravitas Laboratories Private Limited, Greater Noida
| 8182606
| IS 617 (2024) |
Aluminium and Aluminium Alloys Ingots for Remelting and Castings for General Engineering Purposes â Specification (Fourth Revision) |
- |
15000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl-6.1, Table-1(Si) |
- |
250 |
|
- |
| Cl-6.1, Table-1(Fe) |
- |
250 |
|
- |
| Cl-6.1, Table-1(Cu) |
- |
200 |
|
- |
| Cl-6.1, Table-1(Mn) |
- |
200 |
|
- |
| Cl-6.1, Table-1(Mg) |
- |
200 |
|
- |
| Cl-6.1, Table-1(Cr) |
- |
200 |
|
- |
| Cl-6.1, Table-1(Ni) |
- |
200 |
|
- |
| Cl-6.1, Table-1(Zn) |
- |
200 |
|
- |
| Cl-6.1, Table-1(Pb) |
- |
200 |
|
- |
| Cl-6.1, Table-1(Sn) |
- |
250 |
|
- |
| Cl-6.1, Table-1(Ti) |
- |
200 |
|
- |
| Cl-6.1, Table-1(Others elements Each) |
- |
200 |
|
- |
| Cl-6.1, Table-1(Others elements Total) |
- |
300 |
|
- |
| Cl-6.1, Table-1(Aluminium) |
- |
250 |
|
- |
| Cl-6.2(The chemical analysis) |
- |
250 |
|
- |
| Cl-7.1, Table-2(Sand-Cast Alloys- Tensile Strength) |
- |
600 |
|
- |
| Cl-7.1, Table-2(Sand-Cast Alloys- Proof Stress) |
- |
500 |
|
- |
| Cl-7.1, Table-2(Sand-Cast Alloys- Elongation) |
- |
500 |
|
- |
| Cl-7.1, Table-2(Sand-Cast Alloys- Brinell Hardness HBW) |
- |
600 |
|
- |
| Cl-7.1, Table-3(Chill Cast Alloys- Tensile Strength) |
- |
600 |
|
- |
| Cl-7.1, Table-3(Chill Cast Alloys- Proof Stress) |
- |
600 |
|
- |
| Cl-7.1, Table-3(Chill Cast Alloys- Elongation) |
- |
500 |
|
- |
| Cl-7.1, Table-3(Chill Cast Alloys- Brinell Hardness HBW) |
- |
500 |
|
- |
| Cl-7.1, Table-4(Investment-Cast Alloys- Tensile Strength) |
- |
500 |
|
- |
| Cl-7.1, Table-4(Investment-Cast Alloys- Proof Stress) |
- |
600 |
|
- |
| Cl-7.1, Table-4(Investment-Cast Alloys- Elongation) |
- |
500 |
|
- |
| Cl-7.1, Table-4(Investment-Cast Alloys-Brinell Hardness) |
- |
600 |
|
- |
| Cl-7.2(Tensile Tests) |
- |
600 |
|
- |
| Cl-7.3(Test Pieces) |
- |
0 |
|
- |
| Cl-7.4(Hardness) |
- |
600 |
|
- |
| Cl-8(Freedom from Defects) |
- |
500 |
|
- |
| Cl-11(RETEST) |
- |
650 |
|
- |
| Cl. 6(Silicon) |
- |
250 |
|
- |
| Cl. 6(Iron) |
- |
250 |
|
- |
| Cl. 6(Copper) |
- |
250 |
|
- |
| Cl. 6(Manganese) |
- |
250 |
|
- |
| Cl. 6(Magnesium) |
- |
250 |
|
- |
| Cl. 6(Chromium) |
- |
250 |
|
- |
| Cl. 6(Nickel) |
- |
250 |
|
- |
| Cl. 6(Zinc) |
- |
250 |
|
- |
| Cl. 6(Lead) |
- |
250 |
|
- |
| Cl. 6(Tin) |
- |
250 |
|
- |
| Cl. 6(Titanium) |
- |
250 |
|
- |
| Cl. 6(Others Element Each) |
- |
300 |
|
- |
| Cl. 6(Others Element Total) |
- |
300 |
|
- |
| Cl. 6(Aluminium) |
- |
250 |
|
- |
| Cl. 6(Silver) |
- |
250 |
|
- |
| Cl. 6(Zirconium) |
- |
250 |
|
- |
| Cl. 6(Titanium+Zirconium) |
- |
300 |
|
- |
| Cl. 6(Antimony) |
- |
250 |
|
- |
| Cl. 6(Cobalt) |
- |
200 |
|
- |
| Cl. 6(Antimony+Cobalt) |
- |
300 |
|
- |
| Cl. 6(Beryllium) |
- |
250 |
|
- |
| Cl-6.1, Table-1(Si) |
- |
250 |
|
- |
| Cl-6.1, Table-1(Fe) |
- |
250 |
|
- |
| Cl-6.1, Table-1(Cu) |
- |
250 |
|
- |
| Cl-6.1, Table-1(Mn) |
- |
250 |
|
- |
| Cl-6.1, Table-1(Mg) |
- |
250 |
|
- |
| Cl-6.1, Table-1(Cr) |
- |
250 |
|
- |
| Cl-6.1, Table-1(Ni) |
- |
250 |
|
- |
| Cl-6.1, Table-1(Zn) |
- |
250 |
|
- |
| Cl-6.1, Table-1(Pb) |
- |
250 |
|
- |
| Cl-6.1, Table-1(Sn) |
- |
250 |
|
- |
| Cl-6.1, Table-1(Ti) |
- |
250 |
|
- |
| Cl-6.1, Table-1(Others elements Each) |
- |
250 |
|
- |
| Cl-6.1, Table-1(Others elements Total) |
- |
250 |
|
- |
| Cl-6.1, Table-1(Aluminium) |
- |
250 |
|
- |
| Cl-6.2(The chemical analysis) |
- |
250 |
|
- |
| Cl-7.1, Table-2(Sand-Cast Alloys- Tensile Strength) |
- |
500 |
|
- |
| Cl-7.1, Table-2(Sand-Cast Alloys- Proof Stress) |
- |
500 |
|
- |
| Cl-7.1, Table-2(Sand-Cast Alloys- Elongation) |
- |
500 |
|
- |
| Cl-7.1, Table-2(Sand-Cast Alloys- Brinell Hardness HBW) |
- |
500 |
|
- |
| Cl-7.1, Table-3(Chill Cast Alloys- Tensile Strength) |
- |
500 |
|
- |
| Cl-7.1, Table-3(Chill Cast Alloys- Proof Stress) |
- |
500 |
|
- |
| Cl-7.1, Table-3(Chill Cast Alloys- Elongation) |
- |
500 |
|
- |
| Cl-7.1, Table-3(Chill Cast Alloys- Brinell Hardness HBW) |
- |
500 |
|
- |
| Cl-7.1, Table-4(Investment-Cast Alloys- Tensile Strength) |
- |
500 |
|
- |
| Cl-7.1, Table-4(Investment-Cast Alloys- Proof Stress) |
- |
500 |
|
- |
| Cl-7.1, Table-4(Investment-Cast Alloys- Elongation) |
- |
500 |
|
- |
| Cl-7.1, Table-4(Investment-Cast Alloys-Brinell Hardness) |
- |
500 |
|
- |
| Cl-7.2(Tensile Tests) |
- |
1500 |
|
- |
| Cl-7.3(Test Pieces) |
- |
0 |
|
- |
| Cl-7.4(Hardness) |
- |
500 |
|
- |
| Cl-8(Freedom from Defects) |
- |
500 |
|
- |
| Cl-11(RETEST) |
- |
2000 |
|
- |
| Cl. 6(Silicon) |
- |
250 |
|
- |
| Cl. 6(Iron) |
- |
250 |
|
- |
| Cl. 6(Copper) |
- |
250 |
|
- |
| Cl. 6(Manganese) |
- |
250 |
|
- |
| Cl. 6(Magnesium) |
- |
250 |
|
- |
| Cl. 6(Chromium) |
- |
250 |
|
- |
| Cl. 6(Nickel) |
- |
250 |
|
- |
| Cl. 6(Zinc) |
- |
250 |
|
- |
| Cl. 6(Lead) |
- |
250 |
|
- |
| Cl. 6(Tin) |
- |
250 |
|
- |
| Cl. 6(Titanium) |
- |
250 |
|
- |
| Cl. 6(Others Element Each) |
- |
250 |
|
- |
| Cl. 6(Others Element Total) |
- |
250 |
|
- |
| Cl. 6(Aluminium) |
- |
250 |
|
- |
| Cl. 6(Silver) |
- |
250 |
|
- |
| Cl. 6(Zirconium) |
- |
250 |
|
- |
| Cl. 6(Titanium+Zirconium) |
- |
250 |
|
- |
| Cl. 6(Antimony) |
- |
250 |
|
- |
| Cl. 6(Cobalt) |
- |
250 |
|
- |
| Cl. 6(Antimony+Cobalt) |
- |
250 |
|
- |
| Cl. 6(Beryllium) |
- |
250 |
|
- |
|
- |
- Included w.e.f. 13.12.2024
Exclusion: Cl.10 (Pressure Test) |
| 7480 |
Unique Test House LLP
| 9134536
| IS 14650 (2023) |
UNALLOYED AND ALLOYED STEEL INGOT AND SEMI-FINISHED PRODUCTS FOR RE-ROLLING PURPOSES - SPECIFICATION (First Revision) |
- |
9000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Clause - 7.1(CARBON) |
- |
300 |
|
- |
| Clause - 7.1(SULPHUR) |
- |
300 |
|
- |
| Clause - 7.1(PHOSPHURS) |
- |
300 |
|
- |
| Clause - 7.1(MANGANESE) |
- |
300 |
|
- |
| Clause - 7.1(NITROGEN) |
- |
4000 |
|
- |
| As per Clause 10(Dimension) |
- |
200 |
|
- |
| As per Clause 10.1(Dimension Width) |
- |
300 |
|
- |
| As per Clause 10.1(Dimension Thickness) |
- |
300 |
|
- |
| As per Clause 10.2(Dimension Length) |
- |
300 |
|
- |
| As per Clause 11/11.1/11.2/11.3/11.4(Tolerances) |
- |
200 |
|
- |
| As per Clause 11.5(Bend) |
- |
500 |
|
- |
| As per Clause 11.6(Camber) |
- |
300 |
|
- |
| As per Clause 11.7 (i)(Out of Square) |
- |
300 |
|
- |
| As per Clause 11.7 (ii)(Round Corners) |
- |
300 |
|
- |
| As per Clause 11.7 (iii)(Ridges due to gas cutting) |
- |
300 |
|
- |
| As per Clause 11.7 (iv)(Taper (Width variation on top and bottom surface at one location) |
- |
300 |
|
- |
| As per Clause 11.7 (v)(Edge slanting (Width variation on top and bottom surface at one location) |
- |
300 |
|
- |
| As per Clause 11.7 (vi)(Convexity(Difference in thickness from edge to curve) |
- |
300 |
|
- |
| As per Clause 11.7 (vii)(Chamfering (Length variation on top and bottom surface at one location) |
- |
300 |
|
- |
| As per Clause 11.7 (viii)(Wedge (Thickness variation at the edges along the cross section) |
- |
300 |
|
- |
| As per Clause 11.7 (ix)(Scarfing pits) |
- |
300 |
|
- |
| As per Clause 12/12.1/12.2/12.3(Freedom from defects) |
- |
200 |
|
- |
| Clause. 13(Macro examination test.) |
- |
500 |
|
- |
| Clause. 13(Macro examination test.) |
- |
500 |
|
- |
| Clause. 14(Marking) |
- |
200 |
|
- |
| Clause.15(Ordering information) |
- |
200 |
|
- |
| Clause.6.0(Manufacture) |
- |
200 |
|
- |
| Clause.7.1(Silicon) |
- |
300 |
|
- |
| Clause.7.1(Carbon Equbalant) |
- |
300 |
|
- |
| Clause.7.1(Microalloy element) |
- |
300 |
|
- |
|
07 Sep, 2028 |
- Included w.e.f. 29.11.2024
Exclusion: Clause. 13 (Sulphur print, INCLUSION CONTENT) |
| 7481 |
BIS, Eastern Regional Laboratory (ERL)
| None
| IS 7466 (1994) |
Rubber gaskets for pressure cookers - Specifications (First Revison) |
- |
Rs.9480/- View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 3.2 (Workmanship and Finish ) |
- |
|
|
|
| 3.4-Table 1(i) (Requirements of Rubber Used for Gaskets-Hardness IRHD) |
- |
|
|
|
| 3.4-Table 1(ii) (Requirements of Rubber Used for Gaskets-Tensile strength,) |
- |
|
|
|
| 3.4-Table 1(iii) (Requirements of Rubber Used for Gaskets-Elongation at break) |
- |
|
|
|
| 3.4-Table 1(iv-a) (Requirements of Rubber Used for Gaskets-Hardness IRHD(After ageing 3 days in Aie-oven Change From Original Value)) |
- |
|
|
|
| 3.4-Table 1(iv-b) (Requirements of Rubber Used for Gaskets-Tensile strength(After ageing 3 days in Aie-oven Change From Original Value)) |
- |
|
|
|
| 3.4-Table 1(iv-c) (Requirements of Rubber Used for Gaskets-Elongation at break(After ageing 3 days in Aie-oven Change From Original Value)) |
- |
|
|
|
| 3.4-Table 1(v-a) (Requirements of Rubber Used for Gaskets-Hardness IRHD(After ageing in an autoclave Change From Original Value)) |
- |
|
|
|
| 3.4-Table 1(v-b) (Requirements of Rubber Used for Gaskets-Tensile strength(After ageing in an autoclave Change From Original Value)) |
- |
|
|
|
| 3.4-Table 1(v-c) (Requirements of Rubber Used for Gaskets-Elongation at break(After ageing in an autoclave Change From Original Value)) |
- |
|
|
|
| 3.4-Table 1(vi) (Compression set) |
- |
|
|
|
| 3.5-ANNEX C (PERFORMANCE TEST FOR PRESSURE COOKER ) |
- |
|
|
|
| Clause 4.3 Table 1 (Zinc oxide) |
- |
|
|
|
| Clause 3.4 Table 1 (Heavy metal content) |
- |
|
|
|
|
- |
- Chem- C (Total ZnO & Heavy metals only)
SL NO. 1 xii) N-Nitrosamines
xiii) N-Nitrosatables
Mech: Hydrostatic test |
| 7482 |
DELHI TEST HOUSE, Azadhpur
| 8131406
| IS 2785 (2022) |
CHEESE - SPECIFICATION (Second Revision of IS 2785) |
- |
9480 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 5.2.1(Appearance - IS 2785 :2022) |
- |
500 |
|
FOR COMPLETE TESTING - 12000 |
| 5.2.2(Odour and Flavour-IS 2785 :2022) |
- |
500 |
|
FOR COMPLETE TESTING - 12000 |
| 5.2.3(Texture and Consistency) |
- |
500 |
|
FOR COMPLETE TESTING - 12000 |
| 3 and 5.3 Table 1 (i) (a) Hard Pressed Cheese(Moisture IS- 2785-2022) |
- |
1000 |
|
FOR COMPLETE TESTING - 12000 |
| 3 and 5.3 Table 1 (i) (b) Semi Hard Chesse(Moisture IS- 2785-2022) |
- |
1000 |
|
FOR COMPLETE TESTING - 12000 |
| 3 and 5.3 Table 1 (i) (a) Hard Pressed Cheese(Milk fat (On dry basis) IS 12758-2005) |
- |
1000 |
|
FOR COMPLETE TESTING - 12000 |
| 3 and 5.3 Table 1 (i) (b) Semi Hard Chesse(Milk fat (On dry basis) IS 12758-2005) |
- |
1000 |
|
FOR COMPLETE TESTING - 12000 |
| 3 and 5.3 Table 1 (i) © Semi Soft chesse(Moisture IS- 2785-2022) |
- |
1000 |
|
FOR COMPLETE TESTING - 12000 |
| 3 and 5.3 Table 1 (i) © Semi Soft chesse(Milk fat (On dry basis) IS 12758-2005) |
- |
1000 |
|
FOR COMPLETE TESTING - 12000 |
| 3 and 5.3 Table 1 (i) (d) Soft Chesse(Moisture IS- 2785-2022) |
- |
1000 |
|
FOR COMPLETE TESTING - 12000 |
| 3 and 5.3 Table 1 (i) (d) Soft Chesse(Milk fat (On dry basis) IS 12758-2005) |
- |
1000 |
|
FOR COMPLETE TESTING - 12000 |
| 3 and 5.3 Table 1 (i) (d) Extra hard Cheese(Moisture IS- 2785-2022) |
- |
1000 |
|
FOR COMPLETE TESTING - 12000 |
| 3 and 5.3 Table 1 (i) (d) Extra hard Cheese(Milk fat (On dry basis) IS 12758-2005) |
- |
1000 |
|
FOR COMPLETE TESTING - 12000 |
| 3 and 5.3 Table 1 (i) (a) Cheddar(Moisture IS- 2785-2022) |
- |
1000 |
|
FOR COMPLETE TESTING - 12000 |
| 3 and 5.3 Table 1 (i)(Individual or Named Variety Chesses) |
- |
1000 |
|
FOR COMPLETE TESTING - 12000 |
| 3 and 5.3 Table 1 (i) (a) Cheddar(Milk fat (On dry basis) IS 12758-2005) |
- |
1000 |
|
FOR COMPLETE TESTING - 12000 |
| 3 and 5.3 Table 1 (i) (b) Danbo(Moisture IS- 2785-2022) |
- |
1000 |
|
FOR COMPLETE TESTING - 12000 |
| 3 and 5.3 Table 1 (i) (b) Danbo(Milk fat (On dry basis) IS 12758-2005) |
- |
1000 |
|
FOR COMPLETE TESTING - 12000 |
| 3 and 5.3 Table 1 (i) © Edam(Moisture IS- 2785-2022) |
- |
1000 |
|
FOR COMPLETE TESTING - 12000 |
| 3 and 5.3 Table 1 (i) © Edam(Milk fat (On dry basis) IS 12758-2005) |
- |
1000 |
|
FOR COMPLETE TESTING - 12000 |
| 3 and 5.3 Table 1 (i) (d)Gouda(Moisture IS- 2785-2022) |
- |
1000 |
|
FOR COMPLETE TESTING - 12000 |
| 3 and 5.3 Table 1 (i) (d)Gouda(Milk fat (On dry basis) IS 12758-2005) |
- |
1000 |
|
FOR COMPLETE TESTING - 12000 |
| 3 and 5.3 Table 1 (i) (e) Harvati(Moisture IS- 2785-2022) |
- |
1000 |
|
FOR COMPLETE TESTING - 12000 |
| 3 and 5.3 Table 1 (i) (e) Harvati(Milk fat (On dry basis) IS 12758-2005) |
- |
1000 |
|
FOR COMPLETE TESTING - 12000 |
| 3 and 5.3 Table 1 (i) (e) Harvati 30 percent(Moisture IS- 2785-2022) |
- |
1000 |
|
FOR COMPLETE TESTING - 12000 |
| 3 and 5.3 Table 1 (i) (e) Harvati 30 percent(Milk fat (On dry basis) IS 12758-2005) |
- |
1000 |
|
FOR COMPLETE TESTING - 12000 |
| 3 and 5.3 Table 1 (i) (e) Harvati 60 percent(Moisture IS- 2785-2022) |
- |
1000 |
|
FOR COMPLETE TESTING - 12000 |
| 3 and 5.3 Table 1 (i) (e) Harvati 60 percent(Milk fat (On dry basis) IS 12758-2005) |
- |
1000 |
|
FOR COMPLETE TESTING - 12000 |
| 3 and 5.3 Table 1 (i) (f) Tilsiter(Moisture IS- 2785-2022) |
- |
1000 |
|
FOR COMPLETE TESTING - 12000 |
| 3 and 5.3 Table 1 (i) (f) Tilsiter(Milk fat (On dry basis) IS 12758-2005) |
- |
1000 |
|
FOR COMPLETE TESTING - 12000 |
| 3 and 5.3 Table 1 (i) (f) Tilsiter(Milk fat (On dry basis) IS 12758-2005) |
- |
1000 |
|
FOR COMPLETE TESTING - 12000 |
| 3 and 5.3 Table 1 (i) (f) Tilsiter 30 percent(Moisture IS- 2785-2022) |
- |
1000 |
|
FOR COMPLETE TESTING - 12000 |
| 3 and 5.3 Table 1 (i) (f) Tilsiter 30 percent(Milk fat (On dry basis) IS 12758-2005) |
- |
1000 |
|
FOR COMPLETE TESTING - 12000 |
| 3 and 5.3 Table 1 (i) (f) Tilsiter 60 percent(Moisture IS- 2785-2022) |
- |
1000 |
|
FOR COMPLETE TESTING - 12000 |
| 3 and 5.3 Table 1 (i) (f) Tilsiter 60 percent(Milk fat (On dry basis) IS 12758-2005) |
- |
1000 |
|
FOR COMPLETE TESTING - 12000 |
| 3 and 5.3 Table 1 (i) (g) Cottage cheese and creamed cottage cheese(Moisture IS- 2785-2022) |
- |
1000 |
|
FOR COMPLETE TESTING - 12000 |
| 3 and 5.3 Table 1 (i) (g) Cottage cheese and creamed cottage cheese(Milk fat (On dry basis) IS 12758-2005) |
- |
1000 |
|
FOR COMPLETE TESTING - 12000 |
| 3 and 5.3 Table 1 (i) (h) Cream cheese(Moisture IS- 2785-2022) |
- |
1000 |
|
FOR COMPLETE TESTING - 12000 |
| 3 and 5.3 Table 1 (i) (h) Cream cheese(Milk fat (On dry basis) IS 12758-2005) |
- |
1000 |
|
FOR COMPLETE TESTING - 12000 |
| 3 and 5.3 Table 1 (i) (h) Cream cheese(Milk fat (On dry basis) IS 12758-2005) |
- |
1000 |
|
FOR COMPLETE TESTING - 12000 |
| 3 and 5.3 Table 1 (i) (j) Coulommiers(Moisture IS- 2785-2022) |
- |
1000 |
|
FOR COMPLETE TESTING - 12000 |
| 3 and 5.3 Table 1 (i) (j) Coulommiers(Milk fat (On dry basis) IS 12758-2005) |
- |
1000 |
|
FOR COMPLETE TESTING - 12000 |
| 3 and 5.3 Table 1 (i) (k) Camembert 30 percent(Moisture IS- 2785-2022) |
- |
1000 |
|
FOR COMPLETE TESTING - 12000 |
| 3 and 5.3 Table 1 (i) (k) Camembert 30 percent(Milk fat (On dry basis) IS 12758-2005) |
- |
1000 |
|
FOR COMPLETE TESTING - 12000 |
| 3 and 5.3 Table 1 (i) (k) Camembert 40 percent(Moisture IS- 2785-2022) |
- |
1000 |
|
FOR COMPLETE TESTING - 12000 |
| 3 and 5.3 Table 1 (i) (k) Camembert 40 percent(Milk fat (On dry basis) IS 12758-2005) |
- |
1000 |
|
FOR COMPLETE TESTING - 12000 |
| 3 and 5.3 Table 1 (i) (k) Camembert 45 percent(Moisture IS- 2785-2022) |
- |
1000 |
|
FOR COMPLETE TESTING - 12000 |
| 3 and 5.3 Table 1 (i) (k) Camembert 55 percent(Moisture IS- 2785-2022) |
- |
1000 |
|
FOR COMPLETE TESTING - 12000 |
| 3 and 5.3 Table 1 (i) (k) Camembert 55 percent(Milk fat (On dry basis) IS 12758-2005) |
- |
1000 |
|
FOR COMPLETE TESTING - 12000 |
| 3 and 5.3 Table 1 (i) (m) Brie(Moisture IS- 2785-2022) |
- |
1000 |
|
FOR COMPLETE TESTING - 12000 |
| 3 and 5.3 Table 1 (i) (m) Brie(Milk fat (On dry basis) IS 12758-2005) |
- |
1000 |
|
FOR COMPLETE TESTING - 12000 |
| 3 and 5.3 Table 1 (i) (n) Saint Paulin(Moisture IS- 2785-2022) |
- |
1000 |
|
FOR COMPLETE TESTING - 12000 |
| 3 and 5.3 Table 1 (i) (n) Saint Paulin(Milk fat (On dry basis) IS 12758-2005) |
- |
1000 |
|
FOR COMPLETE TESTING - 12000 |
| 3 and 5.3 Table 1 (i) (p) Samsoe(Moisture IS- 2785-2022) |
- |
1000 |
|
FOR COMPLETE TESTING - 12000 |
| 3 and 5.3 Table 1 (i) (p) Samsoe(Milk fat (On dry basis) IS 12758-2005) |
- |
1000 |
|
FOR COMPLETE TESTING - 12000 |
| 3 and 5.3 Table 1 (i) (p) Samsoe 30percent(Moisture IS- 2785-2022) |
- |
1000 |
|
FOR COMPLETE TESTING - 12000 |
| 3 and 5.3 Table 1 (i) (p) Samsoe 30percent(Milk fat (On dry basis) IS 12758-2005) |
- |
1000 |
|
FOR COMPLETE TESTING - 12000 |
| 3 and 5.3 Table 1 (i) (q) Emmentaler(Moisture IS- 2785-2022) |
- |
1000 |
|
FOR COMPLETE TESTING - 12000 |
| 3 and 5.3 Table 1 (i) (q) Emmentaler(Milk fat (On dry basis) IS 12758-2005) |
- |
1000 |
|
FOR COMPLETE TESTING - 12000 |
| 3 and 5.3 Table 1 (i) ® Provolone Smoked(Moisture IS- 2785-2022) |
- |
1000 |
|
FOR COMPLETE TESTING - 12000 |
| 3 and 5.3 Table 1 (i) ® Provolone Smoked(Milk fat (On dry basis) IS 12758-2005) |
- |
1000 |
|
FOR COMPLETE TESTING - 12000 |
| 3 and 5.3 Table 1 (i) ® Provolone Umsmoked(Moisture IS- 2785-2022) |
- |
1000 |
|
FOR COMPLETE TESTING - 12000 |
| 3 and 5.3 Table 1 (i) (r|)Provolone Umsmoked(Milk fat (On dry basis) IS 12758-2005) |
- |
1000 |
|
FOR COMPLETE TESTING - 12000 |
| 3 and 5.3 Table 1 (i) (s) Extra hard grating cheese(Moisture IS- 2785-2022) |
- |
1000 |
|
FOR COMPLETE TESTING - 12000 |
| 3 and 5.3 Table 1 (i) (s) Extra hard grating cheese(Milk fat (On dry basis) IS 12758-2005) |
- |
1000 |
|
FOR COMPLETE TESTING - 12000 |
| 3 and 5.3 Table 1 (i) (t) Mozzarella Cheese(Moisture IS- 2785-2022) |
- |
1000 |
|
FOR COMPLETE TESTING - 12000 |
| 3 and 5.3 Table 1 (i) (t) Mozzarella Cheese(Milk fat (On dry basis) IS 12758-2005) |
- |
1000 |
|
FOR COMPLETE TESTING - 12000 |
| 3 and 5.3 Table 1 (i) (u) Pizza Cheese(Moisture IS- 2785-2022) |
- |
1000 |
|
FOR COMPLETE TESTING - 12000 |
| 3 and 5.3 Table 1 (i) (u) Pizza Cheese(Milk fat (On dry basis) IS 2785-2022) |
- |
1000 |
|
FOR COMPLETE TESTING - 12000 |
| 3 and 5.3 Table 1 (iii) (a) Processed Cheese(a) Moisture IS- 2785-2022 (Processed cheeze when sold in package othen than tin)) |
- |
1000 |
|
FOR COMPLETE TESTING - 12000 |
| 3 and 5.3 Table 1 (iii) (a) Processed Cheese(a) Moisture IS- 2785-2022 (Processed cheeze when sold in package othen than tin)) |
- |
1000 |
|
FOR COMPLETE TESTING - 12000 |
| 4 and 5.3 Table 1 (iii) (a) Processed Cheese(b) Moisture IS- 2785-2022 (Processed cheeze in chiplets, packed sliced)) |
- |
1000 |
|
FOR COMPLETE TESTING - 12000 |
| 3 and 5.3 Table 1 (iii) (a) Processed Cheese(Milk fat (On dry basis) IS 12758-2005) |
- |
1000 |
|
FOR COMPLETE TESTING - 12000 |
| 3 and 5.3 Table 1 (iii) (a) Processed Cheese(Lactose IS 11963) |
- |
1000 |
|
FOR COMPLETE TESTING - 12000 |
| 3 and 5.3 Table 1 (iii) (b) Processed Cheese Spread(Moisture IS- 2785-2022) |
- |
1000 |
|
FOR COMPLETE TESTING - 12000 |
| 3 and 5.3 Table 1 (iii) (b) Processed Cheese Spread(Milk fat (On dry basis) IS 12758-2005) |
- |
1000 |
|
FOR COMPLETE TESTING - 12000 |
| 3 and 5.3 Table 1 (i) (b) Processed Cheese Spread(Lactose -IS 11963) |
- |
1000 |
|
FOR COMPLETE TESTING - 12000 |
| 3 and 5.3 Table 1 (i) (b) Processed Cheese Spread(Lactose -IS 11963) |
- |
1000 |
|
FOR COMPLETE TESTING - 12000 |
| 3 and 5.3 Table 1 (iv) (a) Creamed whey chesses(Milk fat (On dry basis) IS 12758-2005) |
- |
1000 |
|
FOR COMPLETE TESTING - 12000 |
| 3 and 5.3 Table 1 (iv) (b) Whey Cheese(Milk fat (On dry basis) IS 12758-2005) |
- |
1000 |
|
FOR COMPLETE TESTING - 12000 |
| 3 and 5.3 Table 1 (iv) (c) Skimmed whey chesse(Milk fat (On dry basis) IS 12758-2005) |
- |
1000 |
|
FOR COMPLETE TESTING - 12000 |
| 3 and 5.3 Table 1 (a) Soft Cheese in brine(Milk fat (On dry basis) IS 12758-2005) |
- |
1000 |
|
FOR COMPLETE TESTING - 12000 |
| 3 and 5.3 Table 1 (b) Semi-hard cheese in brine(Milk fat (On dry basis) IS 12758-2005) |
- |
1000 |
|
FOR COMPLETE TESTING - 12000 |
| 5.4 Table 2-i(Coliform-IS 5401(P-1):2012) |
- |
1000 |
|
FOR COMPLETE TESTING - 12000 |
| 5.4 Table 2-ii(S.aureus-IS 5887(P-8/Sec-1):2002) |
- |
1000 |
|
FOR COMPLETE TESTING - 12000 |
| 5.4 Table 2-iii(Yeast & Mould count-IS 5403:1999) |
- |
1000 |
|
FOR COMPLETE TESTING - 12000 |
| 5.4 Table 2-iv(E.coli-IS 5887(P-1):1976) |
- |
1000 |
|
FOR COMPLETE TESTING - 12000 |
| 5.4 Table 2-v(Salmonella spp.-IS 5887(P-3/Sec-1):2020) |
- |
1000 |
|
FOR COMPLETE TESTING - 12000 |
| 5.4 Table 2-vi(L.monocytogenes-IS 14988(P-1):2020) |
- |
1000 |
|
FOR COMPLETE TESTING - 12000 |
| 5.5 Table 3-i(Aerobic Colony count - IS 5402 (Part 2)) |
- |
1000 |
|
FOR COMPLETE TESTING - 12000 |
| 5.5 Table 3-ii(Coliform-IS 5401(P-1):2012) |
- |
1000 |
|
FOR COMPLETE TESTING - 12000 |
| 5.5 Table 3-iii(S.aureus-IS 5887(P-8/Sec-1):2002) |
- |
1000 |
|
FOR COMPLETE TESTING - 12000 |
| 5.5 Table 3-iv(E.coli-IS 5887(P-1):1976) |
- |
1000 |
|
FOR COMPLETE TESTING - 12000 |
| 5.5 Table 3-v(Salmonella spp.-IS 5887(P-3/Sec-1):2020) |
- |
1000 |
|
FOR COMPLETE TESTING - 12000 |
| 5.5 Table 3-vi(L.monocytogenes-IS 14988(P-1):2020) |
- |
1000 |
|
FOR COMPLETE TESTING - 12000 |
| CL 5.4, Table 2 (i)(Coliform Count) |
- |
1000 |
|
FOR COMPLETE TESTING - 12000 |
| CL 5.4, Table 2 (iii)(Yeast and Mold Count) |
- |
1000 |
|
FOR COMPLETE TESTING - 12000 |
| CL 5.4, Table 2 (iv)(E. coli) |
- |
1000 |
|
FOR COMPLETE TESTING - 12000 |
| CL 5.4, Table 2 (v)(Salmonella sp) |
- |
1000 |
|
FOR COMPLETE TESTING - 12000 |
| CL 5.4, Table 2 (vi)(Listeria monocytogenes) |
- |
1000 |
|
FOR COMPLETE TESTING - 12000 |
| CL 5.5, Table 3 (i)(Aerobic Colony Count) |
- |
1000 |
|
FOR COMPLETE TESTING - 12000 |
| CL 5.5, Table 3 (ii)(Coliform Count) |
- |
1000 |
|
FOR COMPLETE TESTING - 12000 |
| CL 5.5, Table 3 (iii)(Staphylococcus aureus (Coagulase positive)) |
- |
1000 |
|
FOR COMPLETE TESTING - 12000 |
| CL 5.5, Table 3 (iv)(E. coli) |
- |
1000 |
|
FOR COMPLETE TESTING - 12000 |
| CL 5.5, Table 3 (v)(Salmonella sp) |
- |
1000 |
|
FOR COMPLETE TESTING - 12000 |
| CL 5.5, Table 3 (vi)(Listeria monocytogenes) |
- |
1000 |
|
FOR COMPLETE TESTING - 12000 |
| 3 and 5.3 Table 1 (i) (k) Camembert(Camembert) |
- |
500 |
|
FOR COMPLETE TESTING - 12000 |
| 3 and 5.3 Table 1 (i) (k) Camembert 45 percent(%) |
- |
500 |
|
FOR COMPLETE TESTING - 12000 |
| 3 and 5.3 Table 1 (i) (p) Samsoe(Samsoe) |
- |
500 |
|
FOR COMPLETE TESTING - 12000 |
| 3 and 5.3 Table 1 (i) ® Provolone(Provolone) |
- |
500 |
|
FOR COMPLETE TESTING - 12000 |
| CL 5.4, Table 2 (ii)(Staphylococcus aureus (Coagulase positive)) |
- |
1000 |
|
FOR COMPLETE TESTING - 12000 |
| 3 and 5.3 Table 1 (i)(Cheese) |
- |
500 |
|
FOR COMPLETE TESTING - 12000 |
|
17 Jun, 2027 |
- Included.w.e.f.02.01.2025 |
| 7483 |
Gravitas Laboratories Private Limited, Greater Noida
| 8182606
| IS 2501 (1995) |
Solid drawn copper tubesfor general engineering purposes - Specification (Third Revision) |
- |
15000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl. No.5(Grades) |
- |
1500 |
|
- |
| Cl. No.6(CONDITION) |
- |
500 |
|
- |
| Cl. No. 7(FREEDOM FROM DEFECTS) |
- |
500 |
|
- |
| Cl. No. 8.1(Dimensions) |
- |
800 |
|
- |
| Cl. No. 8.2(Tolerances) |
- |
650 |
|
- |
| Cl. No. 9(CHEMICAL COMPOSITION) |
- |
1300 |
|
- |
| Cl. No. 10.1.1, Table no. 1(Tensile Test) |
- |
1000 |
|
- |
| Cl. No. 10.2(Flattening and Doubling-Over Test) |
- |
950 |
|
- |
| Cl. No. 10.3(Drift Expanding Test) |
- |
850 |
|
- |
| Cl. No. 10.4(Non-Destructive Testing) |
- |
0 |
|
- |
| Cl. No. 10.5("Microscopic Examination ( for 0 Condition
Only )") |
- |
1000 |
|
- |
| Cl. No. 13(Marking) |
- |
0 |
|
- |
| 10.6(Hydrogen Embrittlement Test) |
- |
5000 |
|
- |
| Cl. No.5(Grades) |
- |
0 |
|
- |
| Cl. No.6(CONDITION) |
- |
0 |
|
- |
| Cl. No. 7(FREEDOM FROM DEFECTS) |
- |
500 |
|
- |
| Cl. No. 8.1(Dimensions) |
- |
500 |
|
- |
| Cl. No. 8.2(Tolerances) |
- |
400 |
|
- |
| Cl. No. 9(CHEMICAL COMPOSITION) |
- |
1000 |
|
- |
| Cl. No. 10.1.1, Table no. 1(Tensile Test) |
- |
1000 |
|
- |
| Cl. No. 10.2(Flattening and Doubling-Over Test) |
- |
700 |
|
- |
| Cl. No. 10.3(Drift Expanding Test) |
- |
800 |
|
- |
| Cl. No. 10.4(Non-Destructive Testing) |
- |
0 |
|
- |
| Cl. No. 10.5("Microscopic Examination ( for 0 Condition
Only )") |
- |
1000 |
|
- |
| Cl. No. 13(Marking) |
- |
0 |
|
- |
| 10.6(Hydrogen Embrittlement Test) |
- |
5000 |
|
- |
| Cl. No.5(Grades) |
- |
0 |
|
- |
| Cl. No.6(CONDITION) |
- |
0 |
|
- |
| Cl. No. 7(FREEDOM FROM DEFECTS) |
- |
0 |
|
- |
| Cl. No. 8.1(Dimensions) |
- |
0 |
|
- |
| Cl. No. 8.2(Tolerances) |
- |
0 |
|
- |
| Cl. No. 9(CHEMICAL COMPOSITION) |
- |
0 |
|
- |
| Cl. No. 10.1.1, Table no. 1(Tensile Test) |
- |
0 |
|
- |
| Cl. No. 10.2(Flattening and Doubling-Over Test) |
- |
0 |
|
- |
| Cl. No. 10.3(Drift Expanding Test) |
- |
0 |
|
- |
| Cl. No. 10.4(Non-Destructive Testing) |
- |
0 |
|
- |
| Cl. No. 10.5("Microscopic Examination ( for 0 Condition
Only )") |
- |
0 |
|
- |
| Cl. No. 13(Marking) |
- |
0 |
|
- |
| 10.6(Hydrogen Embrittlement Test) |
- |
0 |
|
- |
|
- |
- Included w.e.f 22.07.2025
Excluding Non destructive testing. |
| 7484 |
Classic Testing & Research Centre (B17), Noida
| 8180826
| IS 302 : Part 2 : SEC 31 (2009) |
Safety of household and similar electrical appliances: Part 2 particular requirements: Sec 31 range hoods |
- |
40000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Clause No - 5(GENERAL CONDITIONS FOR THE TESTS) |
- |
1000 |
|
20% Discount to BIS |
| Clause No - 5.18(linear and angular dimension) |
- |
2000 |
|
20% Discount to BIS |
| Clause No - 6.2(harmfull ingress of water) |
- |
1500 |
|
20% Discount to BIS |
| Clause No - 8.1.1("PROTECTION AGAINST ACCESS TO LIVE
PART- test probe B") |
- |
1500 |
|
20% Discount to BIS |
| Clause No - 8.1.2("PROTECTION AGAINST ACCESS TO LIVE
PART - test probe 13") |
- |
1500 |
|
20% Discount to BIS |
| Clause No - 8.2(Addition) |
- |
1000 |
|
20% Discount to BIS |
| Clause No - 10.1, Table No. -1(power input deviation) |
- |
1000 |
|
20% Discount to BIS |
| Clause No - 13.3("LEAKAGE CURRENT AND ELECTRIC
STRENGTH AT OPERATING TEMPERATURE") |
- |
1500 |
|
20% Discount to BIS |
| Clause No - 13.3,Table No.- 4(voltage for electrical strength) |
- |
1200 |
|
20% Discount to BIS |
| Clause No - 14(Impulse test voltage) |
- |
2000 |
|
20% Discount to BIS |
| Clause No - 15.1.1(MOISTURE RESISTANCE) |
- |
1000 |
|
20% Discount to BIS |
| Clause No -19.7(test is repeated with the capacitor short circuited) |
- |
1000 |
|
20% Discount to BIS |
| Clause No -19.11.4.1(electrostatic discharge) |
- |
1500 |
|
20% Discount to BIS |
| Clause No -19.11.4.3(fast transient) |
- |
1500 |
|
20% Discount to BIS |
| Clause No -19.11.4.4(Voltage dips and interruption) |
- |
1500 |
|
20% Discount to BIS |
| Clause No -21.1(Mechanical strength) |
- |
1000 |
|
20% Discount to BIS |
| Clause No -22.1(construction) |
- |
1000 |
|
20% Discount to BIS |
| Clause No -22.11(push force applied) |
- |
1000 |
|
20% Discount to BIS |
| Clause No -24.1.2(safety isolating transformer) |
- |
1000 |
|
20% Discount to BIS |
| Clause No -24.1.3(for switches) |
- |
1000 |
|
20% Discount to BIS |
| Clause No -24.1.4(for automatic control) |
- |
1000 |
|
20% Discount to BIS |
| Clause No -24.1.5(for innterconnection couplers) |
- |
1000 |
|
20% Discount to BIS |
| Clause No -24.4(plug and socket) |
- |
1000 |
|
20% Discount to BIS |
| Clause No -25.8, Table no -11(conductor resistance) |
- |
1000 |
|
20% Discount to BIS |
| Clause No -25.5(dimension for pins) |
- |
1000 |
|
20% Discount to BIS |
| Clause No -27.6(for circuit board) |
- |
1000 |
|
20% Discount to BIS |
| Clause No -29.2(comparative tracking index) |
- |
1000 |
|
20% Discount to BIS |
| Clause No -29.3.3(dry heat test) |
- |
1000 |
|
20% Discount to BIS |
| Clause No -30.2.1(glow wire test) |
- |
1500 |
|
20% Discount to BIS |
| Clause No -30.101("incorporate combustible
material") |
- |
1000 |
|
20% Discount to BIS |
| 15(MOISTURE RESISTANCE) |
- |
1500 |
|
20% Discount to BIS |
| 16(LEAKAGE CURRENT AND ELECTRIC STRENGTH) |
- |
1500 |
|
20% Discount to BIS |
| 17(OVERLOAD PROTECTION OF TRANSFORMERS AND ASSOCIATED CIRCUITS) |
- |
1500 |
|
20% Discount to BIS |
| 18(ENDURANCE) |
- |
1000 |
|
20% Discount to BIS |
| 28(SCREWS AND CONNECTIONS) |
- |
1500 |
|
20% Discount to BIS |
| 31(RESISTANCE TO RUSTING) |
- |
1000 |
|
20% Discount to BIS |
|
15 Oct, 2027 |
- Included w.e.f.12.12.2024 Exclusion Cl 19.11.4.2 (Radiated fields) |
| 7485 |
Bharat Test House Pvt. Ltd. 1668 Sonipat
| 9168306
| IS 1254 (2007) |
Corrugated aluminium sheet (Fourth Revision) |
Corrugated Aluminum Sheet |
14000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 3(FREEDOM FROM DEFECTS) |
- |
1500 |
|
- |
| 4(SUPPLY OF MATERIAL) |
- |
0 |
|
- |
| 5(PROFILE) |
- |
0 |
|
- |
| 6(MATERIAL) |
- |
7000 |
|
- |
| 7.2(WIDTH) |
- |
1000 |
|
- |
| 7.3(LENGTH) |
- |
1000 |
|
- |
| 7.4(SQUARENESS) |
- |
1000 |
|
- |
| 7.5(Depth and Pitch of the Corrugation) |
- |
1000 |
|
- |
| 8(FINISH) |
- |
1300 |
|
- |
| 9(MARKING) |
- |
200 |
|
- |
|
- |
- Included w.e.f 13.02.2025 |
| 7486 |
Gravitas Laboratories Private Limited, Greater Noida
| 8182606
| IS 10773 (1995) |
Wrought copper tubes for refrigeration and air - Conditioning purposes - Specification (First Revision) |
- |
14500 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 7(Freedom from defect) |
- |
200 |
|
- |
| 8(Dimension and Tolerance) |
- |
300 |
|
- |
| 9.1 - 1(Copper) |
- |
400 |
|
- |
| 9.1 - 1(Arsenic) |
- |
400 |
|
- |
| 9.1 - 1(Iron) |
- |
400 |
|
- |
| 9.1 - 1(Lead) |
- |
400 |
|
- |
| 9.1 - 1(Nickel) |
- |
400 |
|
- |
| 9.1 - 1(Tin) |
- |
300 |
|
- |
| 9.1 - 1(Phosphorus) |
- |
300 |
|
- |
| 9.1 - 1(Total impurities) |
- |
1000 |
|
- |
| 10.1.1 - 2(Tensile Test) |
- |
600 |
|
- |
| 10.1.1 - 2(0.2 Proof stress) |
- |
500 |
|
- |
| 10.1.1 - 2(Percentage elongation on 50mm gauge length) |
- |
400 |
|
- |
| 9.1 - 1(Manganese) |
- |
300 |
|
- |
| 9.1 - 1(Aluminium) |
- |
300 |
|
- |
| 9.1 - 1(Zinc) |
- |
300 |
|
- |
| 10.2(Flattening Test) |
- |
500 |
|
- |
| 10.3(Drift Expanding Test) |
- |
500 |
|
- |
| 10.5(Microscopic Examination) |
- |
1000 |
|
- |
| 10.6(Hydrogen Embrittlement Test) |
- |
1200 |
|
- |
| 11.1(Residue Test Or cleanliness test) |
- |
1200 |
|
- |
| Cl-11.2(Residue Test Or cleanliness test) |
- |
1200 |
|
- |
| 7(Freedom from defect) |
- |
500 |
|
- |
| 8(Dimension and Tolerance) |
- |
450 |
|
- |
| 9.1 - 1(Copper) |
- |
300 |
|
- |
| 9.1 - 1(Arsenic) |
- |
250 |
|
- |
| 9.1 - 1(Iron) |
- |
300 |
|
- |
| 9.1 - 1(Lead) |
- |
300 |
|
- |
| 9.1 - 1(Nickel) |
- |
300 |
|
- |
| 9.1 - 1(Tin) |
- |
300 |
|
- |
| 9.1 - 1(Phosphorus) |
- |
300 |
|
- |
| 9.1 - 1(Total impurities) |
- |
700 |
|
- |
| 10.1.1 - 2(Tensile Test) |
- |
700 |
|
- |
| 10.1.1 - 2(0.2 Proof stress) |
- |
650 |
|
- |
| 10.1.1 - 2(Percentage elongation on 50mm gauge length) |
- |
500 |
|
- |
| 9.1 - 1(Manganese) |
- |
250 |
|
- |
| 9.1 - 1(Aluminium) |
- |
250 |
|
- |
| 9.1 - 1(Zinc) |
- |
250 |
|
- |
| 10.2(Flattening Test) |
- |
400 |
|
- |
| 10.3(Drift Expanding Test) |
- |
500 |
|
- |
| 10.5(Microscopic Examination) |
- |
1000 |
|
- |
| 10.6(Hydrogen Embrittlement Test) |
- |
1200 |
|
- |
| 11.1(Residue Test Or cleanliness test) |
- |
800 |
|
- |
| Cl-11.2(Residue Test Or cleanliness test) |
- |
750 |
|
- |
| 7(Freedom from defect) |
- |
0 |
|
- |
| 8(Dimension and Tolerance) |
- |
0 |
|
- |
| 9.1 - 1(Copper) |
- |
0 |
|
- |
| 9.1 - 1(Arsenic) |
- |
0 |
|
- |
| 9.1 - 1(Iron) |
- |
0 |
|
- |
| 9.1 - 1(Lead) |
- |
0 |
|
- |
| 9.1 - 1(Nickel) |
- |
0 |
|
- |
| 9.1 - 1(Tin) |
- |
0 |
|
- |
| 9.1 - 1(Phosphorus) |
- |
0 |
|
- |
| 9.1 - 1(Total impurities) |
- |
0 |
|
- |
| 10.1.1 - 2(Tensile Test) |
- |
0 |
|
- |
| 10.1.1 - 2(0.2 Proof stress) |
- |
0 |
|
- |
| 10.1.1 - 2(Percentage elongation on 50mm gauge length) |
- |
0 |
|
- |
| 9.1 - 1(Manganese) |
- |
0 |
|
- |
| 9.1 - 1(Aluminium) |
- |
0 |
|
- |
| 9.1 - 1(Zinc) |
- |
0 |
|
- |
| 10.2(Flattening Test) |
- |
0 |
|
- |
| 10.3(Drift Expanding Test) |
- |
0 |
|
- |
| 10.5(Microscopic Examination) |
- |
0 |
|
- |
| 10.6(Hydrogen Embrittlement Test) |
- |
0 |
|
- |
| 11.1(Residue Test Or cleanliness test) |
- |
0 |
|
- |
| Cl-11.2(Residue Test Or cleanliness test) |
- |
0 |
|
- |
|
- |
- Included w.e.f 22.07.2025
Excluding hydrostatic test pneumatic test eddy current test |
| 7487 |
WELL TECH TEST AND RESEARCH CENTER, DERABASSI
| 9177306
| IS 737 (2024) |
WROUGHT ALUMINIUM AND ALUMINIUM ALLOY SHEET AND STRIP FOR GENERAL ENGINEERING PURPOSES SPECIFICATION (Fifth Revision) |
AS PER TABLE 1 |
15000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl. 4(Ordering Information - IS 737) |
- |
100 |
|
- |
| Cl. 4 (a)(Grade/ Thickness - IS 737) |
- |
500 |
|
- |
| Cl. 4 (b)(Condition - IS 737) |
- |
100 |
|
- |
| Cl. 4 (c)(Quantity in Kg - IS 737) |
- |
100 |
|
- |
| Cl. 4 (d)(Size - Thickness X Width X Length (T X W X L) in mm for sheets and (T X W) in mm for Strips/ Coils - IS 737) |
- |
500 |
|
- |
| Cl. 4 (e)(Coil ID and Coil Weight for Strips/ Coils - IS 737) |
- |
250 |
|
- |
| Cl. 4 (f)(Core/ Spool Requirement for Coils - IS 737) |
- |
100 |
|
- |
| Cl. 4 (g)(Packing Mode - IS 737) |
- |
100 |
|
- |
| Cl. 5(Supply for Material - IS 737/ IS 10259) |
- |
250 |
|
- |
| Cl. 6(Freedom from Defects - IS 737) |
- |
500 |
|
- |
| Cl. 7(Chemical Composition - IS 504/ IS 504 (Part-1 to 12)/ IS 504 (Part-13 to 16)/ ASTM E 1251/ IS 11035) |
- |
4500 |
|
- |
| Cl. 7(Si - IS 504 (Part-1)/ ASTM E 1251/ IS 11035) |
- |
500 |
|
- |
| Cl. 7(Fe - IS 504 (Part-2)/ ASTM E 1251/ IS 11035) |
- |
500 |
|
- |
| Cl. 7(Cu - IS 504 (Part-3)/ ASTM E 1251/ IS 11035) |
- |
500 |
|
- |
| Cl. 7(Mn - IS 504 (Part-5)/ ASTM E 1251/ IS 11035) |
- |
500 |
|
- |
| Cl. 7(Mg - IS 504 (Part-6)/ ASTM E 1251/ IS 11035) |
- |
500 |
|
- |
| Cl. 7(Cr - IS 504 (Part-8)/ ASTM E 1251/ IS 11035) |
- |
500 |
|
- |
| Cl. 7(Zn - IS 504 (Part-4)/ ASTM E 1251/ IS 11035) |
- |
500 |
|
- |
| Cl. 7(Ti - IS 504 (Part-11)/ ASTM E 1251/ IS 11035) |
- |
800 |
|
- |
| Cl. 7(Others (Each) - IS 504/ IS 504 (Part-1 to 12)/ IS 504 (Part-13 to 16)/ ASTM E 1251/ IS 11035) |
- |
500 |
|
- |
| Cl. 7(Others (Total) - IS 504/ IS 504 (Part-1 to 12)/ IS 504 (Part-13 to 16)/ ASTM E 1251/ IS 11035) |
- |
500 |
|
- |
| Cl. 7(Al - IS 504) |
- |
1000 |
|
- |
| Cl. 8(Mechanical Properties - IS 1608 (Part-1)) |
- |
2500 |
|
- |
| Cl. 8.1(0.2% Proof Stress - IS 1608 (Part-1)) |
- |
2000 |
|
- |
| Cl. 8.1(Tensile Strength - IS 1608 (Part-1)) |
- |
2500 |
|
- |
| Cl. 8.1(Elongation on 50mm Gauge Length - IS 1608 (Part-1)) |
- |
1500 |
|
- |
| Cl. 8.2(Bend Test - IS 1599) |
- |
1500 |
|
- |
| Cl. 9(Condition - IS 737/ IS 5052) |
- |
100 |
|
- |
| Cl. 10(Dimensions and Tolerances - IS 737/ IS 2676) |
- |
2500 |
|
- |
| Cl. 11(Selection of Test Samples - IS 737) |
- |
100 |
|
- |
| Cl. 11.1(Sheet and Strip of Aluminium or Non - Heat Treatable Aluminium Alloy - IS 737) |
- |
100 |
|
- |
| Cl. 11.2(Sheet and Strip of Heat - Treatable Aluminium Alloys - IS 737) |
- |
100 |
|
- |
| Cl. 12(Retests - IS 737/ IS 10259) |
- |
50 |
|
- |
| Cl. 13(Packaging - IS 737/ IS 10259) |
- |
100 |
|
- |
| Cl. 13.1(Marking - IS 737) |
- |
500 |
|
- |
| Cl. 4(Ordering Information - IS 737) |
- |
0 |
|
- |
| Cl. 4 (a)(Grade/ Thickness - IS 737) |
- |
0 |
|
- |
| Cl. 4 (b)(Condition - IS 737) |
- |
0 |
|
- |
| Cl. 4 (c)(Quantity in Kg - IS 737) |
- |
0 |
|
- |
| Cl. 4 (d)(Size - Thickness X Width X Length (T X W X L) in mm for sheets and (T X W) in mm for Strips/ Coils - IS 737) |
- |
0 |
|
- |
| Cl. 4 (e)(Coil ID and Coil Weight for Strips/ Coils - IS 737) |
- |
0 |
|
- |
| Cl. 4 (f)(Core/ Spool Requirement for Coils - IS 737) |
- |
0 |
|
- |
| Cl. 4 (g)(Packing Mode - IS 737) |
- |
0 |
|
- |
| Cl. 5(Supply for Material - IS 737/ IS 10259) |
- |
0 |
|
- |
| Cl. 6(Freedom from Defects - IS 737) |
- |
0 |
|
- |
| Cl. 7(Chemical Composition - IS 504/ IS 504 (Part-1 to 12)/ IS 504 (Part-13 to 16)/ ASTM E 1251/ IS 11035) |
- |
0 |
|
- |
| Cl. 7(Si - IS 504 (Part-1)/ ASTM E 1251/ IS 11035) |
- |
0 |
|
- |
| Cl. 7(Fe - IS 504 (Part-2)/ ASTM E 1251/ IS 11035) |
- |
0 |
|
- |
| Cl. 7(Cu - IS 504 (Part-3)/ ASTM E 1251/ IS 11035) |
- |
0 |
|
- |
| Cl. 7(Mn - IS 504 (Part-5)/ ASTM E 1251/ IS 11035) |
- |
0 |
|
- |
| Cl. 7(Mg - IS 504 (Part-6)/ ASTM E 1251/ IS 11035) |
- |
0 |
|
- |
| Cl. 7(Cr - IS 504 (Part-8)/ ASTM E 1251/ IS 11035) |
- |
0 |
|
- |
| Cl. 7(Zn - IS 504 (Part-4)/ ASTM E 1251/ IS 11035) |
- |
0 |
|
- |
| Cl. 7(Ti - IS 504 (Part-11)/ ASTM E 1251/ IS 11035) |
- |
0 |
|
- |
| Cl. 7(Others (Each) - IS 504/ IS 504 (Part-1 to 12)/ IS 504 (Part-13 to 16)/ ASTM E 1251/ IS 11035) |
- |
0 |
|
- |
| Cl. 7(Others (Total) - IS 504/ IS 504 (Part-1 to 12)/ IS 504 (Part-13 to 16)/ ASTM E 1251/ IS 11035) |
- |
0 |
|
- |
| Cl. 7(Al - IS 504) |
- |
0 |
|
- |
| Cl. 8(Mechanical Properties - IS 1608 (Part-1)) |
- |
0 |
|
- |
| Cl. 8.1(0.2% Proof Stress - IS 1608 (Part-1)) |
- |
0 |
|
- |
| Cl. 8.1(Tensile Strength - IS 1608 (Part-1)) |
- |
0 |
|
- |
| Cl. 8.1(Elongation on 50mm Gauge Length - IS 1608 (Part-1)) |
- |
0 |
|
- |
| Cl. 8.2(Bend Test - IS 1599) |
- |
0 |
|
- |
| Cl. 9(Condition - IS 737/ IS 5052) |
- |
0 |
|
- |
| Cl. 10(Dimensions and Tolerances - IS 737/ IS 2676) |
- |
0 |
|
- |
| Cl. 11(Selection of Test Samples - IS 737) |
- |
0 |
|
- |
| Cl. 11.1(Sheet and Strip of Aluminium or Non - Heat Treatable Aluminium Alloy - IS 737) |
- |
0 |
|
- |
| Cl. 11.2(Sheet and Strip of Heat - Treatable Aluminium Alloys - IS 737) |
- |
0 |
|
- |
| Cl. 12(Retests - IS 737/ IS 10259) |
- |
0 |
|
- |
| Cl. 13(Packaging - IS 737/ IS 10259) |
- |
0 |
|
- |
| Cl. 13.1(Marking - IS 737) |
- |
0 |
|
- |
| Cl. 4(Ordering Information - IS 737) |
- |
0 |
|
- |
| Cl. 4 (a)(Grade/ Thickness - IS 737) |
- |
0 |
|
- |
| Cl. 4 (b)(Condition - IS 737) |
- |
0 |
|
- |
| Cl. 4 (c)(Quantity in Kg - IS 737) |
- |
0 |
|
- |
| Cl. 4 (d)(Size - Thickness X Width X Length (T X W X L) in mm for sheets and (T X W) in mm for Strips/ Coils - IS 737) |
- |
0 |
|
- |
| Cl. 4 (e)(Coil ID and Coil Weight for Strips/ Coils - IS 737) |
- |
0 |
|
- |
| Cl. 4 (f)(Core/ Spool Requirement for Coils - IS 737) |
- |
0 |
|
- |
| Cl. 4 (g)(Packing Mode - IS 737) |
- |
0 |
|
- |
| Cl. 5(Supply for Material - IS 737/ IS 10259) |
- |
0 |
|
- |
| Cl. 6(Freedom from Defects - IS 737) |
- |
0 |
|
- |
| Cl. 7(Chemical Composition - IS 504/ IS 504 (Part-1 to 12)/ IS 504 (Part-13 to 16)/ ASTM E 1251/ IS 11035) |
- |
0 |
|
- |
| Cl. 7(Si - IS 504 (Part-1)/ ASTM E 1251/ IS 11035) |
- |
0 |
|
- |
| Cl. 7(Fe - IS 504 (Part-2)/ ASTM E 1251/ IS 11035) |
- |
0 |
|
- |
| Cl. 7(Cu - IS 504 (Part-3)/ ASTM E 1251/ IS 11035) |
- |
0 |
|
- |
| Cl. 7(Mn - IS 504 (Part-5)/ ASTM E 1251/ IS 11035) |
- |
0 |
|
- |
| Cl. 7(Mg - IS 504 (Part-6)/ ASTM E 1251/ IS 11035) |
- |
0 |
|
- |
| Cl. 7(Cr - IS 504 (Part-8)/ ASTM E 1251/ IS 11035) |
- |
0 |
|
- |
| Cl. 7(Zn - IS 504 (Part-4)/ ASTM E 1251/ IS 11035) |
- |
0 |
|
- |
| Cl. 7(Ti - IS 504 (Part-11)/ ASTM E 1251/ IS 11035) |
- |
0 |
|
- |
| Cl. 7(Others (Each) - IS 504/ IS 504 (Part-1 to 12)/ IS 504 (Part-13 to 16)/ ASTM E 1251/ IS 11035) |
- |
0 |
|
- |
| Cl. 7(Others (Total) - IS 504/ IS 504 (Part-1 to 12)/ IS 504 (Part-13 to 16)/ ASTM E 1251/ IS 11035) |
- |
0 |
|
- |
| Cl. 7(Al - IS 504) |
- |
0 |
|
- |
| Cl. 8(Mechanical Properties - IS 1608 (Part-1)) |
- |
0 |
|
- |
| Cl. 8.1(0.2% Proof Stress - IS 1608 (Part-1)) |
- |
0 |
|
- |
| Cl. 8.1(Tensile Strength - IS 1608 (Part-1)) |
- |
0 |
|
- |
| Cl. 8.1(Elongation on 50mm Gauge Length - IS 1608 (Part-1)) |
- |
0 |
|
- |
| Cl. 8.2(Bend Test - IS 1599) |
- |
0 |
|
- |
| Cl. 9(Condition - IS 737/ IS 5052) |
- |
0 |
|
- |
| Cl. 10(Dimensions and Tolerances - IS 737/ IS 2676) |
- |
0 |
|
- |
| Cl. 11(Selection of Test Samples - IS 737) |
- |
0 |
|
- |
| Cl. 11.1(Sheet and Strip of Aluminium or Non - Heat Treatable Aluminium Alloy - IS 737) |
- |
0 |
|
- |
| Cl. 11.2(Sheet and Strip of Heat - Treatable Aluminium Alloys - IS 737) |
- |
0 |
|
- |
| Cl. 12(Retests - IS 737/ IS 10259) |
- |
0 |
|
- |
| Cl. 13(Packaging - IS 737/ IS 10259) |
- |
0 |
|
- |
| Cl. 13.1(Marking - IS 737) |
- |
0 |
|
- |
|
30 Mar, 2027 |
- Included w.e.f 28.03.2025 |
| 7488 |
Atmy Analytical Labs Pvt. Ltd., Faridabad
| 8167506
| IS 737 (2024) |
WROUGHT ALUMINIUM AND ALUMINIUM ALLOY SHEET AND STRIP FOR GENERAL ENGINEERING PURPOSES SPECIFICATION (Fifth Revision) |
ALL |
14900 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl. 4(Ordering Information - IS 737) |
- |
14900 |
|
- |
| Cl. 4 (a)(Grade/ Thickness - IS 737) |
- |
14900 |
|
- |
| Cl. 4 (b)(Condition - IS 737) |
- |
14900 |
|
- |
| Cl. 4 (c)(Quantity in Kg - IS 737) |
- |
14900 |
|
- |
| Cl. 4 (d)(Size - Thickness X Width X Length (T X W X L) in mm for sheets and (T X W) in mm for Strips/ Coils - IS 737) |
- |
14900 |
|
- |
| Cl. 4 (e)(Coil ID and Coil Weight for Strips/ Coils - IS 737) |
- |
14900 |
|
- |
| Cl. 4 (f)(Core/ Spool Requirement for Coils - IS 737) |
- |
14900 |
|
- |
| Cl. 4 (g)(Packing Mode - IS 737) |
- |
14900 |
|
- |
| Cl. 5(Supply for Material - IS 737/ IS 10259) |
- |
14900 |
|
- |
| Cl. 6(Freedom from Defects - IS 737) |
- |
14900 |
|
- |
| Cl. 7(Chemical Composition - IS 504/ IS 504 (Part-1 to 12)/ IS 504 (Part-13 to 16)/ ASTM E 1251/ IS 11035) |
- |
14900 |
|
- |
| Cl. 7(Si - IS 504 (Part-1)/ ASTM E 1251/ IS 11035) |
- |
14900 |
|
- |
| Cl. 7(Fe - IS 504 (Part-2)/ ASTM E 1251/ IS 11035) |
- |
14900 |
|
- |
| Cl. 7(Cu - IS 504 (Part-3)/ ASTM E 1251/ IS 11035) |
- |
14900 |
|
- |
| Cl. 7(Mn - IS 504 (Part-5)/ ASTM E 1251/ IS 11035) |
- |
14900 |
|
- |
| Cl. 7(Mg - IS 504 (Part-6)/ ASTM E 1251/ IS 11035) |
- |
14900 |
|
- |
| Cl. 7(Cr - IS 504 (Part-8)/ ASTM E 1251/ IS 11035) |
- |
14900 |
|
- |
| Cl. 7(Zn - IS 504 (Part-4)/ ASTM E 1251/ IS 11035) |
- |
14900 |
|
- |
| Cl. 7(Ti - IS 504 (Part-11)/ ASTM E 1251/ IS 11035) |
- |
14900 |
|
- |
| Cl. 7(Others (Each) - IS 504/ IS 504 (Part-1 to 12)/ IS 504 (Part-13 to 16)/ ASTM E 1251/ IS 11035) |
- |
14900 |
|
- |
| Cl. 7(Others (Total) - IS 504/ IS 504 (Part-1 to 12)/ IS 504 (Part-13 to 16)/ ASTM E 1251/ IS 11035) |
- |
14900 |
|
- |
| Cl. 7(Al - IS 504) |
- |
14900 |
|
- |
| Cl. 8(Mechanical Properties - IS 1608 (Part-1)) |
- |
14900 |
|
- |
| Cl. 8.1(0.2% Proof Stress - IS 1608 (Part-1)) |
- |
14900 |
|
- |
| Cl. 8.1(Tensile Strength - IS 1608 (Part-1)) |
- |
14900 |
|
- |
| Cl. 8.1(Elongation on 50mm Gauge Length - IS 1608 (Part-1)) |
- |
14900 |
|
- |
| Cl. 8.2(Bend Test - IS 1599) |
- |
14900 |
|
- |
| Cl. 9(Condition - IS 737/ IS 5052) |
- |
14900 |
|
- |
| Cl. 10(Dimensions and Tolerances - IS 737/ IS 2676) |
- |
14900 |
|
- |
| Cl. 11(Selection of Test Samples - IS 737) |
- |
14900 |
|
- |
| Cl. 11.1(Sheet and Strip of Aluminium or Non - Heat Treatable Aluminium Alloy - IS 737) |
- |
14900 |
|
- |
| Cl. 11.2(Sheet and Strip of Heat - Treatable Aluminium Alloys - IS 737) |
- |
14900 |
|
- |
| Cl. 12(Retests - IS 737/ IS 10259) |
- |
14900 |
|
- |
| Cl. 13(Packaging - IS 737/ IS 10259) |
- |
14900 |
|
- |
| Cl. 13.1(Marking - IS 737) |
- |
14900 |
|
- |
| Cl. 4(Ordering Information - IS 737) |
- |
- |
|
- |
| Cl. 4 (a)(Grade/ Thickness - IS 737) |
- |
- |
|
- |
| Cl. 4 (b)(Condition - IS 737) |
- |
- |
|
- |
| Cl. 4 (c)(Quantity in Kg - IS 737) |
- |
- |
|
- |
| Cl. 4 (d)(Size - Thickness X Width X Length (T X W X L) in mm for sheets and (T X W) in mm for Strips/ Coils - IS 737) |
- |
- |
|
- |
| Cl. 4 (e)(Coil ID and Coil Weight for Strips/ Coils - IS 737) |
- |
- |
|
- |
| Cl. 4 (f)(Core/ Spool Requirement for Coils - IS 737) |
- |
- |
|
- |
| Cl. 4 (g)(Packing Mode - IS 737) |
- |
- |
|
- |
| Cl. 5(Supply for Material - IS 737/ IS 10259) |
- |
- |
|
- |
| Cl. 6(Freedom from Defects - IS 737) |
- |
- |
|
- |
| Cl. 7(Chemical Composition - IS 504/ IS 504 (Part-1 to 12)/ IS 504 (Part-13 to 16)/ ASTM E 1251/ IS 11035) |
- |
- |
|
- |
| Cl. 7(Si - IS 504 (Part-1)/ ASTM E 1251/ IS 11035) |
- |
- |
|
- |
| Cl. 7(Fe - IS 504 (Part-2)/ ASTM E 1251/ IS 11035) |
- |
- |
|
- |
| Cl. 7(Cu - IS 504 (Part-3)/ ASTM E 1251/ IS 11035) |
- |
- |
|
- |
| Cl. 7(Mn - IS 504 (Part-5)/ ASTM E 1251/ IS 11035) |
- |
- |
|
- |
| Cl. 7(Mg - IS 504 (Part-6)/ ASTM E 1251/ IS 11035) |
- |
- |
|
- |
| Cl. 7(Cr - IS 504 (Part-8)/ ASTM E 1251/ IS 11035) |
- |
- |
|
- |
| Cl. 7(Zn - IS 504 (Part-4)/ ASTM E 1251/ IS 11035) |
- |
- |
|
- |
| Cl. 7(Ti - IS 504 (Part-11)/ ASTM E 1251/ IS 11035) |
- |
- |
|
- |
| Cl. 7(Others (Each) - IS 504/ IS 504 (Part-1 to 12)/ IS 504 (Part-13 to 16)/ ASTM E 1251/ IS 11035) |
- |
- |
|
- |
| Cl. 7(Others (Total) - IS 504/ IS 504 (Part-1 to 12)/ IS 504 (Part-13 to 16)/ ASTM E 1251/ IS 11035) |
- |
- |
|
- |
| Cl. 7(Al - IS 504) |
- |
- |
|
- |
| Cl. 8(Mechanical Properties - IS 1608 (Part-1)) |
- |
- |
|
- |
| Cl. 8.1(0.2% Proof Stress - IS 1608 (Part-1)) |
- |
- |
|
- |
| Cl. 8.1(Tensile Strength - IS 1608 (Part-1)) |
- |
- |
|
- |
| Cl. 8.1(Elongation on 50mm Gauge Length - IS 1608 (Part-1)) |
- |
- |
|
- |
| Cl. 8.2(Bend Test - IS 1599) |
- |
- |
|
- |
| Cl. 9(Condition - IS 737/ IS 5052) |
- |
- |
|
- |
| Cl. 10(Dimensions and Tolerances - IS 737/ IS 2676) |
- |
- |
|
- |
| Cl. 11(Selection of Test Samples - IS 737) |
- |
- |
|
- |
| Cl. 11.1(Sheet and Strip of Aluminium or Non - Heat Treatable Aluminium Alloy - IS 737) |
- |
- |
|
- |
| Cl. 11.2(Sheet and Strip of Heat - Treatable Aluminium Alloys - IS 737) |
- |
- |
|
- |
| Cl. 12(Retests - IS 737/ IS 10259) |
- |
- |
|
- |
| Cl. 13(Packaging - IS 737/ IS 10259) |
- |
- |
|
- |
| Cl. 13.1(Marking - IS 737) |
- |
- |
|
- |
|
25 Feb, 2027 |
- - |
| 7489 |
Gravitas Laboratories Private Limited, Greater Noida
| 8182606
| IS 5484 (2023) |
EC GRADE ALUMINIUM ROD PRODUCED BY CONTINUOUS CASTING AND ROLLING - SPECIFICATION |
- |
9000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl-6.1(Grades and chemical composition of EC grade aluminium rod produced) |
- |
2000 |
|
- |
| Cl-6.2(Chemical analysis of the material) |
- |
2000 |
|
- |
| Cl-7.1(General condition for delivery and inspection relating) |
- |
500 |
|
- |
| Cl-9(Ultimate tensile strength and elongation) |
- |
750 |
|
- |
| Cl-10.1(Resistivity) |
- |
1000 |
|
- |
| Cl-10.1(electrical conductivity) |
- |
1000 |
|
- |
| Cl-10.1.1(Resistivity and Conductivity Limit) |
- |
1000 |
|
- |
| Cl-11(Dimensions) |
- |
500 |
|
- |
| Cl-13(Finish and freedom from defects) |
- |
200 |
|
- |
| CL 9(ULTIMATE TENSILE STRENGTH AND ELONGATION) |
- |
750 |
|
- |
| CL 11(DIMENSIONS) |
- |
500 |
|
- |
| CL 13(FINISH AND FREEDOM FROM DEFECTS) |
- |
200 |
|
- |
| 9(Elongation) |
- |
750 |
|
- |
| Cl-6.1(Grades and chemical composition of EC grade aluminium rod produced) |
- |
2000 |
|
- |
| Cl-6.2(Chemical analysis of the material) |
- |
2000 |
|
- |
| Cl-7.1(General condition for delivery and inspection relating) |
- |
1500 |
|
- |
| Cl-9(Ultimate tensile strength and elongation) |
- |
750 |
|
- |
| Cl-10.1(Resistivity) |
- |
2000 |
|
- |
| Cl-10.1(electrical conductivity) |
- |
2000 |
|
- |
| Cl-10.1.1(Resistivity and Conductivity Limit) |
- |
2000 |
|
- |
| Cl-11(Dimensions) |
- |
500 |
|
- |
| Cl-13(Finish and freedom from defects) |
- |
500 |
|
- |
| CL 9(ULTIMATE TENSILE STRENGTH AND ELONGATION) |
- |
750 |
|
- |
| CL 11(DIMENSIONS) |
- |
500 |
|
- |
| CL 13(FINISH AND FREEDOM FROM DEFECTS) |
- |
500 |
|
- |
| 9(Elongation) |
- |
750 |
|
- |
|
- |
- Included w.e.f. 24.12.2024 |
| 7490 |
BIS, Eastern Regional Laboratory (ERL)
| None
| IS 16581 (2018) |
High density polyethylene (HDPE)/polypropylene (PP) woven sacks for packing of solid ammonium nitrate for explosives - Specification |
For all type |
Rs.6550/- View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 5.1 Table 1 (i) (Dimensions, mm
a) Length) |
- |
|
|
|
| 5.1 Table 1 (i) (Dimensions, mm
b) Width) |
- |
|
|
|
| 5.1 Table 1 (iii) (Picks per dm) |
- |
|
|
|
| 5.1 Table 1 (iv) (Mass of fabric, g/m2) |
- |
|
|
|
| 5.1 Table 1 (v) (Average breaking strength of fabric, Min [Raveled strip method, 200 mm × 50 mm1), N²) (kgf)]:) |
- |
|
|
|
| 5.1 Table 1 (vi) (Minimum breaking strength of bottom seam (Strip method), N²) (kgf), Min) |
- |
|
|
|
| 5.1 Table 1 (vii) (Elongation at break of fabric (Raveled strip method), percent :) |
- |
|
|
|
| 5.1 Table 1 (v) (Average breaking strength of fabric, Min [Raveled strip method, 200 mm × 50 mm1), N²) (kgf)]:
a) Length-wise
b) Width-wise) |
- |
|
|
|
| 5.1 Table 1 (ii) (Ends per dm) |
- |
|
|
|
| 5.1 Table 1 (iii) (Picks per dm) |
- |
|
|
|
| 5.1 Table 1 (iv) (Mass of fabric, g/m2) |
- |
|
|
|
| 5.1 Table 1 (vi) (Minimum breaking strength of bottom seam (Strip method), N²) (kgf), Min) |
- |
|
|
|
| 5.1 Table 1 (vii) (Elongation at break of fabric (Raveled strip method), percent :) |
- |
|
|
|
| 6 (PRINTING, PACKING AND MARKING) |
- |
|
|
|
| 6 (PRINTING, PACKING AND MARKING) |
- |
|
|
|
|
- |
- Complete |
| 7491 |
CIPET, Hyderabad
| 6111634
| IS 17546 (2021) |
Chlorinated polyvinyl chloride CPVC fittings for potable hot and cold water distribution supplies Specification |
CPVC fittings |
164250 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 3.1(Nominal Size(DN)) |
- |
500 |
|
FOR BIS 25 % DISCOUNT |
| 3.2(Nominal Outside Diameter) |
- |
500 |
|
FOR BIS 25 % DISCOUNT |
| 3.3(Mean Inside Diameter of Socket at Entry) |
- |
500 |
|
FOR BIS 25 % DISCOUNT |
| 3.4(Mean Inside Diameter of Socket at Shoulder (Bottom)) |
- |
500 |
|
FOR BIS 25 % DISCOUNT |
| 3.4(Mean Inside Diameter of Socket at Shoulder (Bottom)) |
- |
500 |
|
FOR BIS 25 % DISCOUNT |
| 3.5(Out-of-Roundness (Ovality)) |
- |
500 |
|
FOR BIS 25 % DISCOUNT |
| 3.6(Nominal Wall Thickness) |
- |
500 |
|
FOR BIS 25 % DISCOUNT |
| 3.7(Minimum Wall Thickness) |
- |
500 |
|
FOR BIS 25 % DISCOUNT |
| 3.8(Tolerance) |
- |
500 |
|
FOR BIS 25 % DISCOUNT |
| 3.9(Working Pressure) |
- |
0 |
|
FOR BIS 25 % DISCOUNT |
| 3.1(Standard Dimension Ratio) |
- |
0 |
|
FOR BIS 25 % DISCOUNT |
| 3.11(Type Tests) |
- |
15800 |
|
FOR BIS 25 % DISCOUNT |
| 3.11(Acceptance Tests) |
- |
850 |
|
FOR BIS 25 % DISCOUNT |
| 6(Composition) |
- |
16900 |
|
FOR BIS 25 % DISCOUNT |
| 7(Dimensions of fitting) |
- |
500 |
|
FOR BIS 25 % DISCOUNT |
| 8.2(Opacity) |
- |
700 |
|
FOR BIS 25 % DISCOUNT |
| 8.1(Visual Appearance) |
- |
500 |
|
FOR BIS 25 % DISCOUNT |
| 8.3(Stress Relief Test) |
- |
700 |
|
FOR BIS 25 % DISCOUNT |
| 8.4(Vicat softening Temperature) |
- |
1100 |
|
FOR BIS 25 % DISCOUNT |
| 8.5(Density) |
- |
700 |
|
FOR BIS 25 % DISCOUNT |
| 8.6(Effect on water) |
- |
2000 |
|
FOR BIS 25 % DISCOUNT |
| 9(Mechanical Properties) |
- |
127150 |
|
FOR BIS 25 % DISCOUNT |
| 11(Marking) |
- |
500 |
|
FOR BIS 25 % DISCOUNT |
| Cl-6.2.2(Compound Chlorine Content) |
- |
16900 |
|
FOR BIS 25 % DISCOUNT |
| Cl-6.2.5(Verification of the Malfunction Temperature) |
- |
16000 |
|
FOR BIS 25 % DISCOUNT |
| Cl-9.1(Hydrostatic Characteristics) |
- |
16650 |
|
FOR BIS 25 % DISCOUNT |
| Cl-9.2(Thermal Stability by Hydrostatic Pressure Testing) |
- |
110500 |
|
FOR BIS 25 % DISCOUNT |
| 3.1(Nominal Size(DN)) |
- |
0 |
|
- |
| 3.2(Nominal Outside Diameter) |
- |
0 |
|
- |
| 3.3(Mean Inside Diameter of Socket at Entry) |
- |
0 |
|
- |
| 3.4(Mean Inside Diameter of Socket at Shoulder (Bottom)) |
- |
0 |
|
- |
| 3.4(Mean Inside Diameter of Socket at Shoulder (Bottom)) |
- |
0 |
|
- |
| 3.5(Out-of-Roundness (Ovality)) |
- |
0 |
|
- |
| 3.6(Nominal Wall Thickness) |
- |
0 |
|
- |
| 3.7(Minimum Wall Thickness) |
- |
0 |
|
- |
| 3.8(Tolerance) |
- |
0 |
|
- |
| 3.9(Working Pressure) |
- |
0 |
|
- |
| 3.1(Standard Dimension Ratio) |
- |
0 |
|
- |
| 3.11(Type Tests) |
- |
0 |
|
- |
| 3.11(Acceptance Tests) |
- |
0 |
|
- |
| 6(Composition) |
- |
0 |
|
- |
| 7(Dimensions of fitting) |
- |
0 |
|
- |
| 8.2(Opacity) |
- |
0 |
|
- |
| 8.1(Visual Appearance) |
- |
0 |
|
- |
| 8.3(Stress Relief Test) |
- |
0 |
|
- |
| 8.4(Vicat softening Temperature) |
- |
0 |
|
- |
| 8.5(Density) |
- |
0 |
|
- |
| 8.6(Effect on water) |
- |
0 |
|
- |
| 9(Mechanical Properties) |
- |
0 |
|
- |
| 11(Marking) |
- |
0 |
|
- |
| Cl-6.2.2(Compound Chlorine Content) |
- |
0 |
|
- |
| Cl-6.2.5(Verification of the Malfunction Temperature) |
- |
0 |
|
- |
| Cl-9.1(Hydrostatic Characteristics) |
- |
0 |
|
- |
| Cl-9.2(Thermal Stability by Hydrostatic Pressure Testing) |
- |
0 |
|
- |
| 3.1(Nominal Size(DN)) |
- |
0 |
|
- |
| 3.2(Nominal Outside Diameter) |
- |
0 |
|
- |
| 3.3(Mean Inside Diameter of Socket at Entry) |
- |
0 |
|
- |
| 3.4(Mean Inside Diameter of Socket at Shoulder (Bottom)) |
- |
0 |
|
- |
| 3.4(Mean Inside Diameter of Socket at Shoulder (Bottom)) |
- |
0 |
|
- |
| 3.5(Out-of-Roundness (Ovality)) |
- |
0 |
|
- |
| 3.6(Nominal Wall Thickness) |
- |
0 |
|
- |
| 3.7(Minimum Wall Thickness) |
- |
0 |
|
- |
| 3.8(Tolerance) |
- |
0 |
|
- |
| 3.9(Working Pressure) |
- |
0 |
|
- |
| 3.1(Standard Dimension Ratio) |
- |
0 |
|
- |
| 3.11(Type Tests) |
- |
0 |
|
- |
| 3.11(Acceptance Tests) |
- |
0 |
|
- |
| 6(Composition) |
- |
0 |
|
- |
| 7(Dimensions of fitting) |
- |
0 |
|
- |
| 8.2(Opacity) |
- |
0 |
|
- |
| 8.1(Visual Appearance) |
- |
0 |
|
- |
| 8.3(Stress Relief Test) |
- |
0 |
|
- |
| 8.4(Vicat softening Temperature) |
- |
0 |
|
- |
| 8.5(Density) |
- |
0 |
|
- |
| 8.6(Effect on water) |
- |
0 |
|
- |
| 9(Mechanical Properties) |
- |
0 |
|
- |
| 11(Marking) |
- |
0 |
|
- |
| Cl-6.2.2(Compound Chlorine Content) |
- |
0 |
|
- |
| Cl-6.2.5(Verification of the Malfunction Temperature) |
- |
0 |
|
- |
| Cl-9.1(Hydrostatic Characteristics) |
- |
0 |
|
- |
| Cl-9.2(Thermal Stability by Hydrostatic Pressure Testing) |
- |
0 |
|
- |
|
23 Feb, 2027 |
- Included.w.e.f.30.01.2025 |
| 7492 |
Classic Testing & Research Centre (B17), Noida
| 8180826
| IS 302 : Part 2 : Sec 75 (2018) |
Safety of Household and Similar Electrical Appliances Part 2 Particular Requirements Section 75 Commercial Dispensing Appliances and Vending Machines |
- |
35000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 32(Radiation, toxicity and similar hazards) |
- |
500 |
|
20% Discount to BIS |
| 31(Resistance to rusting) |
- |
1000 |
|
20% Discount to BIS |
| 30.2.4(Resistance to heat and fire) |
- |
1000 |
|
20% Discount to BIS |
| 30.2(Resistance to heat and fire) |
- |
1000 |
|
20% Discount to BIS |
| 30.1(Resistance to heat and fire) |
- |
1000 |
|
20% Discount to BIS |
| 29.3(Clearances, creepage distances and solid insulation) |
- |
1000 |
|
20% Discount to BIS |
| 29.2(Clearances, creepage distances and solid insulation) |
- |
1000 |
|
20% Discount to BIS |
| 29.2(Clearances, creepage distances and solid insulation) |
- |
1000 |
|
20% Discount to BIS |
| 29.1, Table No.- 16, Table No.- 17 & Table No.18(Clearances, creepage distances and solid insulation) |
- |
1000 |
|
20% Discount to BIS |
| 29.1, Table No.- 16, Table No.- 17 & Table No.18(Clearances, creepage distances and solid insulation) |
- |
1000 |
|
20% Discount to BIS |
| 28.2 to 28.4(Screws and connections) |
- |
1000 |
|
20% Discount to BIS |
| 28.1, Table No.-14(Screws and connections) |
- |
1000 |
|
20% Discount to BIS |
| 27.6(Provision for earthing) |
- |
1000 |
|
20% Discount to BIS |
| 27.5(Provision for earthing) |
- |
1000 |
|
20% Discount to BIS |
| 27.1 to 27.4(Provision for earthing) |
- |
1000 |
|
20% Discount to BIS |
| 26.10 & 26.11(Terminals for external conductors) |
- |
1000 |
|
20% Discount to BIS |
| 26.9(Terminals for external conductors) |
- |
1000 |
|
20% Discount to BIS |
| 26.1 to 26.8(Terminals for external conductors) |
- |
1000 |
|
20% Discount to BIS |
| 25.16 to 25.25(Supply connection and external flexible cords) |
- |
1000 |
|
20% Discount to BIS |
| 25.15(Supply connection and external flexible cords) |
- |
1000 |
|
20% Discount to BIS |
| 25.14(Supply connection and external flexible cords) |
- |
1000 |
|
20% Discount to BIS |
| 25.9 to 25.13(Supply connection and external flexible cords) |
- |
1000 |
|
20% Discount to BIS |
| 25.8, Table No.-11(Supply connection and external flexible cords) |
- |
1000 |
|
20% Discount to BIS |
| 25.5 to 25.7(Supply connection and external flexible cords) |
- |
1000 |
|
20% Discount to BIS |
| 25.4(Supply connection and external flexible cords) |
- |
1000 |
|
20% Discount to BIS |
| 25.3(Supply connection and external flexible cords) |
- |
1000 |
|
20% Discount to BIS |
| 25.2(Supply connection and external flexible cords) |
- |
1000 |
|
20% Discount to BIS |
| 25.1(Supply connection and external flexible cords) |
- |
1000 |
|
20% Discount to BIS |
| 24.101 to 24.103(Components) |
- |
500 |
|
20% Discount to BIS |
| 24.2 to 24.6(Components) |
- |
500 |
|
20% Discount to BIS |
| 24.1(Components) |
- |
500 |
|
20% Discount to BIS |
| 23.101 to 23.102(Internal wiring) |
- |
500 |
|
20% Discount to BIS |
| 23.6 to 23.10(Internal wiring) |
- |
500 |
|
20% Discount to BIS |
| 23.5(Internal wiring) |
- |
500 |
|
20% Discount to BIS |
| 23.4(Internal wiring) |
- |
500 |
|
20% Discount to BIS |
| 23.3(Internal wiring) |
- |
500 |
|
20% Discount to BIS |
| 23.1 & 23.2(Internal wiring) |
- |
500 |
|
20% Discount to BIS |
| 22.101 to 22.114(Constructions) |
- |
500 |
|
20% Discount to BIS |
| 22.13 to 22.48(Constructions) |
- |
500 |
|
20% Discount to BIS |
| 22.12(Constructions) |
- |
500 |
|
20% Discount to BIS |
| 22.11(Constructions) |
- |
500 |
|
20% Discount to BIS |
| 22.11(Constructions) |
- |
500 |
|
20% Discount to BIS |
| 22.7 to 22.10(Constructions) |
- |
500 |
|
20% Discount to BIS |
| 22.6(Constructions) |
- |
500 |
|
20% Discount to BIS |
| 22.5(Constructions) |
- |
500 |
|
20% Discount to BIS |
| 22.4(Constructions) |
- |
500 |
|
20% Discount to BIS |
| 22.3(Constructions) |
- |
500 |
|
20% Discount to BIS |
| 22.2(Constructions) |
- |
500 |
|
20% Discount to BIS |
| 22.1(Constructions) |
- |
500 |
|
20% Discount to BIS |
| 21.2(MECHANICAL STRENGTH) |
- |
1000 |
|
20% Discount to BIS |
| 21.1(MECHANICAL STRENGTH) |
- |
1000 |
|
20% Discount to BIS |
| 20.2(Stability and mechanical hazards) |
- |
1000 |
|
20% Discount to BIS |
| 20.1(Stability and mechanical hazards) |
- |
1000 |
|
20% Discount to BIS |
| 19.101 and 19.102(ABNORMAL OPERATION) |
- |
1000 |
|
20% Discount to BIS |
| 19.1 to 19.13, Table No. - 9(ABNORMAL OPERATION) |
- |
1000 |
|
20% Discount to BIS |
| 17(Overload protection of transformers and associated circuits) |
- |
1000 |
|
20% Discount to BIS |
| 16.3(Insulation resistance test) |
- |
1000 |
|
20% Discount to BIS |
| 16.3(Electric strength test) |
- |
1000 |
|
20% Discount to BIS |
| 16.1 & 16.2(Leakage current test) |
- |
1000 |
|
20% Discount to BIS |
| 15.102(Moisture resistance) |
- |
1000 |
|
20% Discount to BIS |
| 15.102(Moisture resistance) |
- |
1000 |
|
20% Discount to BIS |
| 15.101(Moisture resistance) |
- |
1000 |
|
20% Discount to BIS |
| 15.3(Moisture resistance) |
- |
1000 |
|
20% Discount to BIS |
| 15.2(Moisture resistance) |
- |
1000 |
|
20% Discount to BIS |
| 15.1(Moisture resistance) |
- |
1000 |
|
20% Discount to BIS |
| 14, Table No.- 6 & Table No.-16(Transient over voltages) |
- |
1000 |
|
20% Discount to BIS |
| 13.3 and Table No.- 4(Electric strength test) |
- |
1000 |
|
20% Discount to BIS |
| 13.1, 13.2(Leakage current test) |
- |
1000 |
|
20% Discount to BIS |
| 11.1 to 11.8, Table No.-3(Heating) |
- |
1000 |
|
20% Discount to BIS |
| 10.1 & 10.2 -Table No. 1, Table No. 2(Power Input and Current) |
- |
1000 |
|
20% Discount to BIS |
| 8.1.5(Protection against access to live parts) |
- |
1000 |
|
20% Discount to BIS |
| 8.1.4(Protection against access to live parts) |
- |
1000 |
|
20% Discount to BIS |
| 8.1.3(Protection against access to live parts) |
- |
1000 |
|
20% Discount to BIS |
| 8.1.2(Protection against access to live parts) |
- |
1000 |
|
20% Discount to BIS |
| 8.1, 8.1.1 & 8.2(Protection against access to live parts) |
- |
1000 |
|
20% Discount to BIS |
| 7.14(Legibility & Durability of Markings test) |
- |
1000 |
|
20% Discount to BIS |
| 7.1 to 7.13, 7.15, 7.16(Marking) |
- |
1000 |
|
20% Discount to BIS |
| 32(Radiation, toxicity and similar hazards) |
- |
1000 |
|
20% Discount to BIS |
| 31(Resistance to rusting) |
- |
1000 |
|
20% Discount to BIS |
| 30.2.4(Resistance to heat and fire) |
- |
1000 |
|
20% Discount to BIS |
| 30.2(Resistance to heat and fire) |
- |
1000 |
|
20% Discount to BIS |
| 30.1(Resistance to heat and fire) |
- |
1000 |
|
20% Discount to BIS |
| 29.3(Clearances, creepage distances and solid insulation) |
- |
1000 |
|
20% Discount to BIS |
| 29.2(Clearances, creepage distances and solid insulation) |
- |
1000 |
|
20% Discount to BIS |
| 29.2(Clearances, creepage distances and solid insulation) |
- |
1000 |
|
20% Discount to BIS |
| 29.1, Table No.- 16, Table No.- 17 & Table No.18(Clearances, creepage distances and solid insulation) |
- |
1000 |
|
20% Discount to BIS |
| 29.1, Table No.- 16, Table No.- 17 & Table No.18(Clearances, creepage distances and solid insulation) |
- |
1000 |
|
20% Discount to BIS |
| 28.2 to 28.4(Screws and connections) |
- |
1000 |
|
20% Discount to BIS |
| 28.1, Table No.-14(Screws and connections) |
- |
1000 |
|
20% Discount to BIS |
| 27.6(Provision for earthing) |
- |
1000 |
|
20% Discount to BIS |
| 27.5(Provision for earthing) |
- |
1000 |
|
20% Discount to BIS |
| 27.1 to 27.4(Provision for earthing) |
- |
1000 |
|
20% Discount to BIS |
| 26.10 & 26.11(Terminals for external conductors) |
- |
1000 |
|
20% Discount to BIS |
| 26.9(Terminals for external conductors) |
- |
1000 |
|
20% Discount to BIS |
| 26.1 to 26.8(Terminals for external conductors) |
- |
1000 |
|
20% Discount to BIS |
| 25.16 to 25.25(Supply connection and external flexible cords) |
- |
1000 |
|
20% Discount to BIS |
| 25.15(Supply connection and external flexible cords) |
- |
1000 |
|
20% Discount to BIS |
| 25.14(Supply connection and external flexible cords) |
- |
1000 |
|
20% Discount to BIS |
| 25.9 to 25.13(Supply connection and external flexible cords) |
- |
1000 |
|
20% Discount to BIS |
| 25.8, Table No.-11(Supply connection and external flexible cords) |
- |
1000 |
|
20% Discount to BIS |
| 25.5 to 25.7(Supply connection and external flexible cords) |
- |
1000 |
|
20% Discount to BIS |
| 25.4(Supply connection and external flexible cords) |
- |
1000 |
|
20% Discount to BIS |
| 25.3(Supply connection and external flexible cords) |
- |
1000 |
|
20% Discount to BIS |
| 25.2(Supply connection and external flexible cords) |
- |
1000 |
|
20% Discount to BIS |
| 25.1(Supply connection and external flexible cords) |
- |
1000 |
|
20% Discount to BIS |
| 24.101 to 24.103(Components) |
- |
500 |
|
20% Discount to BIS |
| 24.2 to 24.6(Components) |
- |
500 |
|
20% Discount to BIS |
| 24.1(Components) |
- |
500 |
|
20% Discount to BIS |
| 23.101 to 23.102(Internal wiring) |
- |
500 |
|
20% Discount to BIS |
| 23.6 to 23.10(Internal wiring) |
- |
500 |
|
20% Discount to BIS |
| 23.5(Internal wiring) |
- |
500 |
|
20% Discount to BIS |
| 23.4(Internal wiring) |
- |
500 |
|
20% Discount to BIS |
| 23.3(Internal wiring) |
- |
500 |
|
20% Discount to BIS |
| 23.1 & 23.2(Internal wiring) |
- |
500 |
|
20% Discount to BIS |
| 22.101 to 22.114(Constructions) |
- |
500 |
|
20% Discount to BIS |
| 22.13 to 22.48(Constructions) |
- |
500 |
|
20% Discount to BIS |
| 22.12(Constructions) |
- |
500 |
|
20% Discount to BIS |
| 22.11(Constructions) |
- |
500 |
|
20% Discount to BIS |
| 22.11(Constructions) |
- |
500 |
|
20% Discount to BIS |
| 22.7 to 22.10(Constructions) |
- |
500 |
|
20% Discount to BIS |
| 22.6(Constructions) |
- |
500 |
|
20% Discount to BIS |
| 22.5(Constructions) |
- |
500 |
|
20% Discount to BIS |
| 22.4(Constructions) |
- |
500 |
|
20% Discount to BIS |
| 22.3(Constructions) |
- |
500 |
|
20% Discount to BIS |
| 22.2(Constructions) |
- |
500 |
|
20% Discount to BIS |
| 22.1(Constructions) |
- |
500 |
|
20% Discount to BIS |
| 21.2(MECHANICAL STRENGTH) |
- |
1000 |
|
20% Discount to BIS |
| 21.1(MECHANICAL STRENGTH) |
- |
1000 |
|
20% Discount to BIS |
| 20.2(Stability and mechanical hazards) |
- |
1000 |
|
20% Discount to BIS |
| 20.1(Stability and mechanical hazards) |
- |
1000 |
|
20% Discount to BIS |
| 19.101 and 19.102(ABNORMAL OPERATION) |
- |
1000 |
|
20% Discount to BIS |
| 19.1 to 19.13, Table No. - 9(ABNORMAL OPERATION) |
- |
1000 |
|
20% Discount to BIS |
| 17(Overload protection of transformers and associated circuits) |
- |
1000 |
|
20% Discount to BIS |
| 16.3(Insulation resistance test) |
- |
1000 |
|
20% Discount to BIS |
| 16.3(Electric strength test) |
- |
1000 |
|
20% Discount to BIS |
| 16.1 & 16.2(Leakage current test) |
- |
1000 |
|
20% Discount to BIS |
| 15.102(Moisture resistance) |
- |
1000 |
|
20% Discount to BIS |
| 15.102(Moisture resistance) |
- |
1000 |
|
20% Discount to BIS |
| 15.101(Moisture resistance) |
- |
1000 |
|
20% Discount to BIS |
| 15.3(Moisture resistance) |
- |
1000 |
|
20% Discount to BIS |
| 15.2(Moisture resistance) |
- |
1000 |
|
20% Discount to BIS |
| 15.1(Moisture resistance) |
- |
1000 |
|
20% Discount to BIS |
| 14, Table No.- 6 & Table No.-16(Transient over voltages) |
- |
1000 |
|
20% Discount to BIS |
| 13.3 and Table No.- 4(Electric strength test) |
- |
1000 |
|
20% Discount to BIS |
| 13.1, 13.2(Leakage current test) |
- |
1000 |
|
20% Discount to BIS |
| 11.1 to 11.8, Table No.-3(Heating) |
- |
1000 |
|
20% Discount to BIS |
| 10.1 & 10.2 -Table No. 1, Table No. 2(Power Input and Current) |
- |
1000 |
|
20% Discount to BIS |
| 8.1.5(Protection against access to live parts) |
- |
1000 |
|
20% Discount to BIS |
| 8.1.4(Protection against access to live parts) |
- |
1000 |
|
20% Discount to BIS |
| 8.1.3(Protection against access to live parts) |
- |
1000 |
|
20% Discount to BIS |
| 8.1.2(Protection against access to live parts) |
- |
1000 |
|
20% Discount to BIS |
| 8.1, 8.1.1 & 8.2(Protection against access to live parts) |
- |
1000 |
|
20% Discount to BIS |
| 7.14(Legibility & Durability of Markings test) |
- |
500 |
|
20% Discount to BIS |
| 7.1 to 7.13, 7.15, 7.16(Marking) |
- |
500 |
|
20% Discount to BIS |
| 19.11.4.1(Electrostatic discharges) |
- |
1000 |
|
20% Discount to BIS |
| 19.11.4.3(Fast transient bursts) |
- |
1000 |
|
20% Discount to BIS |
| 19.11.4.4(Surge immunity test) |
- |
1000 |
|
20% Discount to BIS |
| 19.11.4.6(Class 3 Voltage dips and interruptions) |
- |
1000 |
|
20% Discount to BIS |
| 19.11.4.7(Harmonics) |
- |
1000 |
|
20% Discount to BIS |
|
15 Oct, 2027 |
- Included w.e.f.12.12.2024 Exclusion Cl 19.11.4.2 (Radiated fields) CL 19.11.4.5 (Immunity to conducted discharges) |
| 7493 |
Shriram Research Institute
| 6104206
| IS 2052 (2023) |
Compounded feeds for cattle � Specification |
Type 1 & Type 2 |
10800 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl no.4.1(General) |
- |
100 |
|
- |
| Cl no.4.3,7.1, Table no. 1(i)(Moisture) |
- |
500 |
|
Moisture |
| Cl no.4.3,7.1, Table no. 1(ii)(Crude protein (N × 6.25)) |
- |
400 |
|
Crude protein |
| Cl no.4.3, 7.1,Table no. 1(iii)(Crude fat) |
- |
450 |
|
Crude fat |
| Cl no.4.3 ,7.1, Table no. 1(iv)(Crude fibre) |
- |
550 |
|
Crude Fibre |
| Cl no.4.3 ,7.1, Table no. 1(v)(Acid insoluble ash) |
- |
550 |
|
Acid insoluble ash |
| Cl no.4.3,7.1Table no. 1(vi)("Salt (as NaCl based on Na or
Cl), percent by mass") |
- |
300 |
|
Salt |
| Cl no.4.3 7.1,Table no. 1(vii)(Calcium (as Ca)) |
- |
250 |
|
Calcium |
| Cl no.4.3,7.1,Table no. 1(viii)(Total phosphorus) |
- |
750 |
|
Total phosphorus |
| Cl no.4.3,7.1,Table no. 1(ix)(Available phosphorus) |
- |
350 |
|
Available phosphorus |
| Cl no.4.3 ,7.1, Table no. 1(x)(Urea, percent by mass) |
- |
350 |
|
Urea |
| Cl no.4.3,7.1, Table no. 1(xi)(Vitamin A) |
- |
1250 |
|
Vitamin A |
| Cl no.4.3,7.1,Table no. 1(xii)(Vitamin D) |
- |
1000 |
|
Vitamin D3 |
| Cl no.4.3 ,7.1, Table no. 1(xiii)(Vitamin E) |
- |
1000 |
|
Vitamin E |
| Cl no.4.3 ,7.1, Table no. 1(xiv)(Aflatoxin B1) |
- |
1500 |
|
Aflatoxin B1 |
| Cl no.4.3 ,7.1, Table no. 1(xv)(Cadmium) |
- |
750 |
|
Cadmium |
| 4.2.2(Ratio of total nitrogen to sulphur/ IS/ISO 5983 (Part 1)* or IS/ISO 5983 (Part 2) ISO 16634-Sulphur-AnnexB (IS 1664 or EN 15621)) |
- |
750 |
|
Sulphur |
| Cl no.4.2(Ingredients) |
- |
0 |
|
NA |
| 4.3 Table no.1 (i)(Moisture/4 of IS 7874 (Part 1)) |
- |
500 |
|
Moisture |
| 4.3 Table no.1 (ii)("Crude Protein(ODB)/IS/ISO 5983 (Part 1)* or IS 5983 (Part 2) or
ISO 16634-1") |
- |
400 |
|
Crude Protein |
| 4.3 Table no.1 (iii)(Crude fat (ODB) /IS/ISO 6492) |
- |
450 |
|
Crude fat |
| 4.3 Table no.1 (iv)("Crude fibre (ODB)/IS/ISO 6865
") |
- |
550 |
|
Crude fibre |
| 4.3 Table no.1 (v)(Acid insoluble ash (ODB)/Annex A of IS 1712 or IS 14826*) |
- |
550 |
|
Acid insoluble ash |
| 4.3 Table no.1 (vi)("Salt (ODB)(as NaCl based on Na or
Cl)/4 of IS 7874 (Part 2)") |
- |
300 |
|
Salt |
| 4.3 Table no.1 (viii)(Total phosphorus (ODB)/IS 14828* or EN 15621) |
- |
750 |
|
Total phosphorus |
| 4.3 Table no.1 (vii)(Calcium(ODB) (as Ca)/IS 13433 (Part 1) or IS 15121* or EN 15621) |
- |
250 |
|
Calcium |
| 4.3 Table no.1 (ix)(Available phosphorus (ODB)/Annex F of IS 1374) |
- |
350 |
|
Available phosphorus |
| 4.3 Table no.1 (x)(Urea (ODB)/IS 7874 (Part 1) or AOAC 967.07) |
- |
350 |
|
Urea |
| 4.3 Table no.1 (xi)(Vitamin A(ODB)/IS 15120) |
- |
1250 |
|
Vitamin A |
| 4.3 Table no.1 (xii)("Vitamin D3 (ODB)/Annex C * or
J. AOAC Int. 2012, Vol. 95, No. 5, Pages
1487–1494") |
- |
1000 |
|
Vitamin D3 |
| 4.3 Table no.1 (xiii)(Vitamin E(ODB)/IS 15948) |
- |
1000 |
|
Vitamin E |
| 4.3 Table no.1 (xiv)("Aflatoxin B1 (ODB)/IS/ISO 14718* or ISO 17375 or AOAC
2003.02") |
- |
1500 |
|
Aflatoxin B1 |
| 4.3 Table no.1 (xv)(Cadmium (ODB)/EN 17053) |
- |
750 |
|
Cadmium |
| 4.1(General) |
- |
100 |
|
Description |
| Cl no.4.1(General) |
- |
100 |
|
- |
| Cl no.4.3,7.1, Table no. 1(i)(Moisture) |
- |
500 |
|
- |
| Cl no.4.3,7.1, Table no. 1(ii)(Crude protein (N × 6.25)) |
- |
400 |
|
- |
| Cl no.4.3, 7.1,Table no. 1(iii)(Crude fat) |
- |
450 |
|
- |
| Cl no.4.3 ,7.1, Table no. 1(iv)(Crude fibre) |
- |
550 |
|
- |
| Cl no.4.3 ,7.1, Table no. 1(v)(Acid insoluble ash) |
- |
550 |
|
- |
| Cl no.4.3,7.1Table no. 1(vi)("Salt (as NaCl based on Na or
Cl), percent by mass") |
- |
300 |
|
- |
| Cl no.4.3 7.1,Table no. 1(vii)(Calcium (as Ca)) |
- |
250 |
|
- |
| Cl no.4.3,7.1,Table no. 1(viii)(Total phosphorus) |
- |
750 |
|
- |
| Cl no.4.3,7.1,Table no. 1(ix)(Available phosphorus) |
- |
350 |
|
- |
| Cl no.4.3 ,7.1, Table no. 1(x)(Urea, percent by mass) |
- |
350 |
|
- |
| Cl no.4.3,7.1, Table no. 1(xi)(Vitamin A) |
- |
1250 |
|
- |
| Cl no.4.3,7.1,Table no. 1(xii)(Vitamin D) |
- |
1000 |
|
- |
| Cl no.4.3 ,7.1, Table no. 1(xiii)(Vitamin E) |
- |
1000 |
|
- |
| Cl no.4.3 ,7.1, Table no. 1(xiv)(Aflatoxin B1) |
- |
1500 |
|
- |
| Cl no.4.3 ,7.1, Table no. 1(xv)(Cadmium) |
- |
750 |
|
- |
| 4.2.2(Ratio of total nitrogen to sulphur/ IS/ISO 5983 (Part 1)* or IS/ISO 5983 (Part 2) ISO 16634-Sulphur-AnnexB (IS 1664 or EN 15621)) |
- |
750 |
|
- |
| Cl no.4.2(Ingredients) |
- |
0 |
|
- |
| 4.3 Table no.1 (i)(Moisture/4 of IS 7874 (Part 1)) |
- |
500 |
|
- |
| 4.3 Table no.1 (ii)("Crude Protein(ODB)/IS/ISO 5983 (Part 1)* or IS 5983 (Part 2) or
ISO 16634-1") |
- |
400 |
|
- |
| 4.3 Table no.1 (iii)(Crude fat (ODB) /IS/ISO 6492) |
- |
450 |
|
- |
| 4.3 Table no.1 (iv)("Crude fibre (ODB)/IS/ISO 6865
") |
- |
550 |
|
- |
| 4.3 Table no.1 (v)(Acid insoluble ash (ODB)/Annex A of IS 1712 or IS 14826*) |
- |
550 |
|
- |
| 4.3 Table no.1 (vi)("Salt (ODB)(as NaCl based on Na or
Cl)/4 of IS 7874 (Part 2)") |
- |
300 |
|
- |
| 4.3 Table no.1 (viii)(Total phosphorus (ODB)/IS 14828* or EN 15621) |
- |
750 |
|
- |
| 4.3 Table no.1 (vii)(Calcium(ODB) (as Ca)/IS 13433 (Part 1) or IS 15121* or EN 15621) |
- |
250 |
|
- |
| 4.3 Table no.1 (ix)(Available phosphorus (ODB)/Annex F of IS 1374) |
- |
350 |
|
- |
| 4.3 Table no.1 (x)(Urea (ODB)/IS 7874 (Part 1) or AOAC 967.07) |
- |
350 |
|
- |
| 4.3 Table no.1 (xi)(Vitamin A(ODB)/IS 15120) |
- |
1250 |
|
- |
| 4.3 Table no.1 (xii)("Vitamin D3 (ODB)/Annex C * or
J. AOAC Int. 2012, Vol. 95, No. 5, Pages
1487–1494") |
- |
1000 |
|
- |
| 4.3 Table no.1 (xiii)(Vitamin E(ODB)/IS 15948) |
- |
1000 |
|
- |
| 4.3 Table no.1 (xiv)("Aflatoxin B1 (ODB)/IS/ISO 14718* or ISO 17375 or AOAC
2003.02") |
- |
1500 |
|
- |
| 4.3 Table no.1 (xv)(Cadmium (ODB)/EN 17053) |
- |
750 |
|
- |
| 4.1(General) |
- |
100 |
|
- |
| Cl no.4.1(General) |
- |
99.98 |
|
- |
| Cl no.4.3,7.1, Table no. 1(i)(Moisture) |
- |
500 |
|
- |
| Cl no.4.3,7.1, Table no. 1(ii)(Crude protein (N × 6.25)) |
- |
400 |
|
- |
| Cl no.4.3, 7.1,Table no. 1(iii)(Crude fat) |
- |
450 |
|
- |
| Cl no.4.3 ,7.1, Table no. 1(iv)(Crude fibre) |
- |
549.99 |
|
- |
| Cl no.4.3 ,7.1, Table no. 1(v)(Acid insoluble ash) |
- |
550 |
|
- |
| Cl no.4.3,7.1Table no. 1(vi)("Salt (as NaCl based on Na or
Cl), percent by mass") |
- |
300 |
|
- |
| Cl no.4.3 7.1,Table no. 1(vii)(Calcium (as Ca)) |
- |
250 |
|
- |
| Cl no.4.3,7.1,Table no. 1(viii)(Total phosphorus) |
- |
750 |
|
- |
| Cl no.4.3,7.1,Table no. 1(ix)(Available phosphorus) |
- |
350 |
|
- |
| Cl no.4.3 ,7.1, Table no. 1(x)(Urea, percent by mass) |
- |
350 |
|
- |
| Cl no.4.3,7.1, Table no. 1(xi)(Vitamin A) |
- |
1250 |
|
- |
| Cl no.4.3,7.1,Table no. 1(xii)(Vitamin D) |
- |
1000 |
|
- |
| Cl no.4.3 ,7.1, Table no. 1(xiii)(Vitamin E) |
- |
1000 |
|
- |
| Cl no.4.3 ,7.1, Table no. 1(xiv)(Aflatoxin B1) |
- |
1500 |
|
- |
| Cl no.4.3 ,7.1, Table no. 1(xv)(Cadmium) |
- |
750 |
|
- |
| 4.2.2(Ratio of total nitrogen to sulphur/ IS/ISO 5983 (Part 1)* or IS/ISO 5983 (Part 2) ISO 16634-Sulphur-AnnexB (IS 1664 or EN 15621)) |
- |
750 |
|
- |
| Cl no.4.2(Ingredients) |
- |
0 |
|
- |
| 4.3 Table no.1 (i)(Moisture/4 of IS 7874 (Part 1)) |
- |
500 |
|
- |
| 4.3 Table no.1 (ii)("Crude Protein(ODB)/IS/ISO 5983 (Part 1)* or IS 5983 (Part 2) or
ISO 16634-1") |
- |
400 |
|
- |
| 4.3 Table no.1 (iii)(Crude fat (ODB) /IS/ISO 6492) |
- |
450 |
|
- |
| 4.3 Table no.1 (iv)("Crude fibre (ODB)/IS/ISO 6865
") |
- |
550 |
|
- |
| 4.3 Table no.1 (v)(Acid insoluble ash (ODB)/Annex A of IS 1712 or IS 14826*) |
- |
550 |
|
- |
| 4.3 Table no.1 (vi)("Salt (ODB)(as NaCl based on Na or
Cl)/4 of IS 7874 (Part 2)") |
- |
300 |
|
- |
| 4.3 Table no.1 (viii)(Total phosphorus (ODB)/IS 14828* or EN 15621) |
- |
750 |
|
- |
| 4.3 Table no.1 (vii)(Calcium(ODB) (as Ca)/IS 13433 (Part 1) or IS 15121* or EN 15621) |
- |
250 |
|
- |
| 4.3 Table no.1 (ix)(Available phosphorus (ODB)/Annex F of IS 1374) |
- |
350 |
|
- |
| 4.3 Table no.1 (x)(Urea (ODB)/IS 7874 (Part 1) or AOAC 967.07) |
- |
350 |
|
- |
| 4.3 Table no.1 (xi)(Vitamin A(ODB)/IS 15120) |
- |
1250 |
|
- |
| 4.3 Table no.1 (xii)("Vitamin D3 (ODB)/Annex C * or
J. AOAC Int. 2012, Vol. 95, No. 5, Pages
1487–1494") |
- |
1000 |
|
- |
| 4.3 Table no.1 (xiii)(Vitamin E(ODB)/IS 15948) |
- |
1000 |
|
- |
| 4.3 Table no.1 (xiv)("Aflatoxin B1 (ODB)/IS/ISO 14718* or ISO 17375 or AOAC
2003.02") |
- |
1500 |
|
- |
| 4.3 Table no.1 (xv)(Cadmium (ODB)/EN 17053) |
- |
750 |
|
- |
| 4.1(General) |
- |
100 |
|
- |
| Cl no.4.1(General) |
- |
100 |
|
- |
| Cl no.4.3,7.1, Table no. 1(i)(Moisture) |
- |
499.99 |
|
- |
| Cl no.4.3,7.1, Table no. 1(ii)(Crude protein (N × 6.25)) |
- |
400 |
|
- |
| Cl no.4.3, 7.1,Table no. 1(iii)(Crude fat) |
- |
450 |
|
- |
| Cl no.4.3 ,7.1, Table no. 1(iv)(Crude fibre) |
- |
550 |
|
- |
| Cl no.4.3 ,7.1, Table no. 1(v)(Acid insoluble ash) |
- |
500 |
|
- |
| Cl no.4.3,7.1Table no. 1(vi)("Salt (as NaCl based on Na or
Cl), percent by mass") |
- |
300 |
|
- |
| Cl no.4.3 7.1,Table no. 1(vii)(Calcium (as Ca)) |
- |
250 |
|
- |
| Cl no.4.3,7.1,Table no. 1(viii)(Total phosphorus) |
- |
750 |
|
- |
| Cl no.4.3,7.1,Table no. 1(ix)(Available phosphorus) |
- |
350 |
|
- |
| Cl no.4.3 ,7.1, Table no. 1(x)(Urea, percent by mass) |
- |
350 |
|
- |
| Cl no.4.3,7.1, Table no. 1(xi)(Vitamin A) |
- |
1250 |
|
- |
| Cl no.4.3,7.1,Table no. 1(xii)(Vitamin D) |
- |
1000 |
|
- |
| Cl no.4.3 ,7.1, Table no. 1(xiii)(Vitamin E) |
- |
1000 |
|
- |
| Cl no.4.3 ,7.1, Table no. 1(xiv)(Aflatoxin B1) |
- |
1500 |
|
- |
| Cl no.4.3 ,7.1, Table no. 1(xv)(Cadmium) |
- |
750 |
|
- |
| 4.2.2(Ratio of total nitrogen to sulphur/ IS/ISO 5983 (Part 1)* or IS/ISO 5983 (Part 2) ISO 16634-Sulphur-AnnexB (IS 1664 or EN 15621)) |
- |
750 |
|
- |
| Cl no.4.2(Ingredients) |
- |
0 |
|
- |
| 4.3 Table no.1 (i)(Moisture/4 of IS 7874 (Part 1)) |
- |
500 |
|
- |
| 4.3 Table no.1 (ii)("Crude Protein(ODB)/IS/ISO 5983 (Part 1)* or IS 5983 (Part 2) or
ISO 16634-1") |
- |
400 |
|
- |
| 4.3 Table no.1 (iii)(Crude fat (ODB) /IS/ISO 6492) |
- |
450 |
|
- |
| 4.3 Table no.1 (iv)("Crude fibre (ODB)/IS/ISO 6865
") |
- |
550 |
|
- |
| 4.3 Table no.1 (v)(Acid insoluble ash (ODB)/Annex A of IS 1712 or IS 14826*) |
- |
550 |
|
- |
| 4.3 Table no.1 (vi)("Salt (ODB)(as NaCl based on Na or
Cl)/4 of IS 7874 (Part 2)") |
- |
300 |
|
- |
| 4.3 Table no.1 (viii)(Total phosphorus (ODB)/IS 14828* or EN 15621) |
- |
750 |
|
- |
| 4.3 Table no.1 (vii)(Calcium(ODB) (as Ca)/IS 13433 (Part 1) or IS 15121* or EN 15621) |
- |
250 |
|
- |
| 4.3 Table no.1 (ix)(Available phosphorus (ODB)/Annex F of IS 1374) |
- |
350 |
|
- |
| 4.3 Table no.1 (x)(Urea (ODB)/IS 7874 (Part 1) or AOAC 967.07) |
- |
350 |
|
- |
| 4.3 Table no.1 (xi)(Vitamin A(ODB)/IS 15120) |
- |
1250 |
|
- |
| 4.3 Table no.1 (xii)("Vitamin D3 (ODB)/Annex C * or
J. AOAC Int. 2012, Vol. 95, No. 5, Pages
1487–1494") |
- |
1000 |
|
- |
| 4.3 Table no.1 (xiii)(Vitamin E(ODB)/IS 15948) |
- |
1000 |
|
- |
| 4.3 Table no.1 (xiv)("Aflatoxin B1 (ODB)/IS/ISO 14718* or ISO 17375 or AOAC
2003.02") |
- |
1500 |
|
- |
| 4.3 Table no.1 (xv)(Cadmium (ODB)/EN 17053) |
- |
750 |
|
- |
| 4.1(General) |
- |
100 |
|
- |
|
- |
- Included w.e.f.28.03.2025 |
| 7494 |
BIS, Central Laboratory (CL)
| None
| IS 3993 (1993) |
Trays, instruments - Specification (Second Revision) |
- |
Please see remarks. View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4.1 & 4.2 (C - IS 228) |
- |
|
|
|
| 4.1 & 4.2 (Si - IS 228) |
- |
|
|
|
| 4.1 & 4.2 (Mn - IS 228) |
- |
|
|
|
| 4.1 & 4.2 (Ni - IS 228) |
- |
|
|
|
| 4.1 & 4.2 (Cr - IS 228) |
- |
|
|
|
| 4.1 & 4.2 (S - IS 228) |
- |
|
|
|
| 4.1 & 4.2 (P - IS 228) |
- |
|
|
|
| 6.1 & 6.4 (Manufacture, workmanship and finish of Glass Trays - IS 3993) |
- |
|
|
|
| 6.1 & 6.3 (Manufacture, workmanship and finish of Enamelled Iron Trays - IS 3993) |
- |
|
|
|
| 6.1 & 6.2 (Manufacture, workmanship and finish of Stainless Steel Tray) |
- |
|
|
|
| 5.2 -Table-1 (Length -A - IS 3993) |
- |
|
|
|
| 5.2 -Table-1 (Width -B - IS 3993) |
- |
|
|
|
| 5.2 -Table-1 (Height -C - IS 3993) |
- |
|
|
|
| 5.2 -Table-1 (Minimum no of Ribs - IS 3993) |
- |
|
|
|
| 5.2.1 (Thickness of enamel - IS 3993) |
- |
|
|
|
| 6.1 & 6.2 (Manufacture, workmanship and finish of Stainless Steel Tray) |
- |
|
|
|
| 6.1 & 6.3 (Manufacture, workmanship and finish of Enamelled Iron Trays - IS 3993) |
- |
|
|
|
| 6.1 & 6.4 (Manufacture, workmanship and finish of Glass Trays - IS 3993) |
- |
|
|
|
| 8 (MARKING) |
- |
|
|
|
|
- |
- - |
| 7495 |
Classic Testing & Research Centre (B17), Noida
| 8180826
| IS 302 : Part 2 : Sec 8 (1994) |
Safety of household and similar electrical appliances : part 2 particular requirements, section 8 electrical shavers hair, clippers and similar appliances |
- |
25000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 32(Radiation ,Toxicity and similar hazards) |
- |
1000 |
|
- |
| 31(Resistance to Rusting) |
- |
1000 |
|
- |
| 30(Resistance to Heat & Fire) |
- |
1000 |
|
- |
| 29(Clearances, Creepage Distances & Solid Insulation) |
- |
1000 |
|
- |
| 28(Screws & Connection) |
- |
1000 |
|
- |
| 27(Provision For Earthing) |
- |
1000 |
|
- |
| 26(Terminals For External Conductors) |
- |
1000 |
|
- |
| 25(Supply Connection & External Flexible Cables and Cords) |
- |
1000 |
|
- |
| 24(Component) |
- |
1000 |
|
- |
| 23(Internal wiring) |
- |
1000 |
|
- |
| 22(Construction) |
- |
1000 |
|
- |
| 21(Mechanical strength) |
- |
1000 |
|
- |
| 20(Stability & Mechanical Hazards) |
- |
1000 |
|
- |
| 19(Abnormal Operation) |
- |
1000 |
|
- |
| 18(Endurance) |
- |
1000 |
|
- |
| 17(Overload Protection/ Overload Protection of Transformers & Associated Circuits) |
- |
1000 |
|
- |
| 16(Leakage Current and Electric Strength) |
- |
1000 |
|
- |
| 15(Moisture Resistance) |
- |
1000 |
|
- |
| 14(Radio and Television Interference Suppression/ Transient Over Voltage) |
- |
1000 |
|
- |
| 13(Leakage Current and Electric Strength at Operating Temperature) |
- |
1000 |
|
- |
| 11(Temperature Rise/Heating) |
- |
1000 |
|
- |
| 10(Power Input
& Current) |
- |
1000 |
|
- |
| 9(Starting Of Motor Operated Appliances) |
- |
1000 |
|
- |
| 8(Protection against Electric Shock/ Protection against Access to Live Parts) |
- |
1000 |
|
- |
| 7(Marking/ Marking & Instructions) |
- |
1000 |
|
- |
| 6(Classification) |
- |
1000 |
|
- |
| 5(Rating) |
- |
1000 |
|
- |
| 19.11.4.1(Electrostatic discharges) |
- |
1000 |
|
- |
| 19.11.4.3(Fast transient bursts) |
- |
1000 |
|
- |
| 19.11.4.4(Surge immunity test) |
- |
1000 |
|
- |
| 19.11.4.6(Class 3 Voltage dips and interruptions) |
- |
1000 |
|
- |
| 19.11.4.7(Harmonics) |
- |
1000 |
|
- |
|
15 Oct, 2027 |
- Included w.e.f.12.12.2024 Exclusion Cl 19.11.4.2 (Radiated fields) CL 19.11.4.5 (Immunity to conducted discharges) |
| 7496 |
National Council for Cement and Building Materials (NCCBM), Hyderabad
| 6114835
| IS 456 (2000) |
Plain and reinforced concrete - Code of practice (Fourth Revision) |
- |
9011 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl 5.4 .2(pH) |
- |
1750 |
|
-- |
| Cl 5.4 (a)(Acidity) |
- |
605 |
|
-- |
| Cl 5.4 (b)(Alkalinity) |
- |
605 |
|
-- |
| Cl 5.4 Table 1 (i)(Organic Solids) |
- |
880 |
|
-- |
| Cl 5.4 Table 1 (ii)(Inorganic Solids) |
- |
880 |
|
-- |
| Cl 5.4 Table 1 (iii)(Sulphate) |
- |
1750 |
|
-- |
| Cl 5.4 Table 1 (iv)(Chloride) |
- |
2340 |
|
-- |
| Cl 5.4 Table 1 (v)(Suspended Matter) |
- |
880 |
|
-- |
|
14 Aug, 2027 |
- Included w.e.f. 28.05.2019 |
| 7497 |
National Council for Cement and Building Materials (NCCBM), Hyderabad
| 6114835
| IS 3812 : Part 2 (2013) |
Pulverized Fuel Ash - Part 2 : For Use as Admixture in Cement Mortar and Concrete |
- |
39820 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 5.1, 6.1, Table 1(Silicon dioxide (SiO2 ) plus aluminium oxide (Al2O3 ) plus iron oxide (Fe2O3 )) |
- |
7525 |
|
No remarks |
| 5.1, 6.1, Table 1(Silicon dioxide (SiO2 )) |
- |
2145 |
|
No remarks |
| 5.1, 6.1, Table 1(Magnesium oxide (MgO) |
- |
3040 |
|
No remarks |
| 5.1, 6.1, Table 1(Total sulphur as sulphur trioxide (SO3) |
- |
2340 |
|
No remarks |
| 5.1, 6.1, Table 1(Available alkalies as equivalent sodium oxide (Na2O)) |
- |
3990 |
|
No remarks |
| 5.1, 6.1, Table 1(Total chlorides) |
- |
2340 |
|
No remarks |
| 5.1, 6.1, Table 1(Loss on ignition) |
- |
1180 |
|
No remarks |
| 6.2(moisture content) |
- |
2440 |
|
No remarks |
| 7.1, Table 1(Fineness — Specific surface in m2 /kg) |
- |
1950 |
|
No remarks |
| 7.1, Table 1(Particles retained on 45 micron IS sieve (wet sieving)) |
- |
2820 |
|
No remarks |
| 7.1, Table 1(Soundnes) |
- |
3510 |
|
No remarks |
|
14 Aug, 2027 |
- - |
| 7498 |
National Council for Cement and Building Materials (NCCBM), Hyderabad
| 6114835
| IS 12089 (1987) |
Specification for granulated slag for the manufacture portland slag cement |
- |
29850 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 3.1(Physical State) |
- |
2340 |
|
No remarks |
| 3.4.1(glass content ) |
- |
7500 |
|
no |
| 3.2(composition of granulated slag, Manganese Oxide) |
- |
1950 |
|
no |
| 3.2(composition of granulated slag, Magnesium Oxide) |
- |
3040 |
|
no |
| 3.2(composition of granulated slag, Sulphide Sulphur) |
- |
2340 |
|
no |
| 3.3(percentages of major oxides) |
- |
11045 |
|
no |
| 3.4(insoluble residue of dried samples) |
- |
2340 |
|
no |
|
14 Aug, 2027 |
- - |
| 7499 |
National Council for Cement and Building Materials (NCCBM), Hyderabad
| 6114835
| IS 8042 (2015) |
White portland cement - Specification (Third Revision) |
- |
40010 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 5 - Table - 1 i(Ratio of percentage of lime to percentages of silica, alumina and iron oxide - Cl 4 of IS 4032:1985) |
- |
10345 |
|
These testing charges are for determination of CaO, SO3, SiO2, Fe2O3 & Al2O3 to calculate the above mentioned ratio. |
| 5 - Table - 1 ii(Iron oxide - Cl 4.5 of IS 4032:1985) |
- |
2340 |
|
No Remarks |
| 5 - Table - 1 iii(Insoluble residue - Cl 4.10 of IS 4032:1985) |
- |
2340 |
|
No Remarks |
| 5 - Table - 1 iv(Magnesia - Cl 4.8 of IS 4032:1985) |
- |
3040 |
|
No Remarks |
| 5 - Table - 1 v(Total Sulphur Content calculated as Sulphuric Anhydride (SO3) - Cl 4.9 of IS 4032:1985) |
- |
2340 |
|
No Remarks |
| 5 - Table - 1 vi(Loss on ignition - Cl 4.2 of IS 4032:1985) |
- |
1180 |
|
No Remarks |
| 5 - Table - 1 vii(Chloride content - Cl 4.13 of IS 4032:1985) |
- |
2340 |
|
No Remarks |
| 6 -Table 2- i(Fineness 4031 Part 2) |
- |
1950 |
|
No Remarks |
| 6 -Table 2- ii- a(Expansion by Le Chatelier- 4031 Part 3) |
- |
1950 |
|
No Remarks |
| 6 -Table 2- ii- b(Expansion by Autoclave- 4031 Part 3) |
- |
3510 |
|
No Remarks |
| 6 -Table 2- iii- a(Setting Time Initial- 4031 Part 5) |
- |
875 |
|
No Remarks |
| 6 -Table 2-iii- b(Setting Time Final- 4031 Part 5) |
- |
875 |
|
No Remarks |
| 6 -Table 2- iv- a(Compressive Strength At 72 hrs ± 1 hr - IS 4031 Part 6) |
- |
2000 |
|
No Remarks |
| 6 -Table 2- iv- b(Compressive Strength At 168 hrs ± 2 hr - IS 4031 Part 6) |
- |
2270 |
|
No Remarks |
| 6 -Table 2- iv- c(Compressive Strength At 672 hrs ± 4 hr - IS 4031 Part 6) |
- |
2660 |
|
No Remarks |
| 6 -Table 2- v(Transverse Strength - IS 4031 Part 8 (Optional)) |
- |
14240 |
|
For 3, 7 & 28 days |
| 6 -Table 2- vi(Degree of whiteness-Annex B) |
- |
2340 |
|
No Remarks |
|
14 Aug, 2027 |
- - |
| 7500 |
National Council for Cement and Building Materials (NCCBM), Hyderabad
| 6114835
| IS 12330 (1988) |
Specificatioon for sulphate resisting Portland cement |
- |
39620 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4.1 - Table - 1 i(Ratio of percentage of lime to percentages of silica, alumina and iron oxide - Cl 4 of IS 4032:1985) |
- |
10345 |
|
-- |
| 4.1 - Table - 1 ii(Insoluble residue - Cl 4.10 of IS 4032:1985) |
- |
2340 |
|
No remarks |
| 4.1 - Table - 1 iii(Magnesia - Cl 4.8 of IS 4032:1985) |
- |
3040 |
|
No remarks |
| 4.1 - Table - 1 iv(Total Sulphur Content calculated as Sulphuric Anhydride (SO3) - Cl 4.9 of IS 4032:1985) |
- |
2340 |
|
No remarks |
| 4.1 - Table - 1 v(Tricalcium aluminate (C3A) - Cl 4 of IS 4032:1985) |
- |
5380 |
|
No remarks |
| 4.1 - Table - 1 vi(Tetracalcium alumino ferrite phase plus twice the tricalcium aluminate ( C4AF + 2C3A ) - Cl 4 of IS 4032:1985) |
- |
5380 |
|
No remarks |
| 4.1 - Table - 1 vii(Total loss on ignition - Cl 4.2 of IS 4032:1985) |
- |
1180 |
|
No remarks |
| 5.1(Fineness 4031 Part 2) |
- |
1950 |
|
No remarks |
| 5.2.1(Expansion by Le Chatelier- 4031 Part 3) |
- |
1950 |
|
No remarks |
| 5.2.1(Expansion by Autoclave- 4031 Part 3) |
- |
3510 |
|
No remarks |
| 5.3 a)(Setting Time Initial- 4031 Part 5) |
- |
875 |
|
No remarks |
| 5.3 b)(Setting Time Final- 4031 Part 5) |
- |
875 |
|
No remarks |
| 5.5 i)(Compressive Strength At 72 hrs ± 1 hr - IS 4031 Part 6) |
- |
2000 |
|
No remarks |
| 5.5 ii)(Compressive Strength At 168 hrs ± 2 hr - IS 4031 Part 6) |
- |
2660 |
|
No remarks |
| 5.5 iii)(Compressive Strength At 672 hrs ± 4 hr - IS 4031 Part 6) |
- |
2820 |
|
No remarks |
| 5.6(Transverse Strength - IS 4031 Part 8 (Optional)) |
- |
14240 |
|
For 3, 7 & 28 days Strength |
|
14 Aug, 2027 |
- - |