| 7711 |
MIGHTY TESTING PRIVATE LIMITED, GHAZIABAD
| 8185126
| IS 16333 : Part 3 (2022) |
Mobile phone handsets: Part 3 Indian language support for mobile phone handsets - Specific requirements(Second Revision) |
-- |
15000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 5.1(Inputting of text) |
- |
7000 |
|
- |
| 5.2(Message Readability) |
- |
8000 |
|
-- |
| 6(Marking) |
- |
0 |
|
-- |
| "Cl.6.1 "(Marking) |
- |
0 |
|
-- |
| "Cl.6.2 "(BIS Certification Marking) |
- |
0 |
|
-- |
| 4(Requirements) |
- |
0 |
|
- |
| 5(Tests) |
- |
0 |
|
-- |
| 6(Marking) |
- |
0 |
|
-- |
|
05 May, 2028 |
- - |
| 7712 |
MIGHTY TESTING PRIVATE LIMITED, GHAZIABAD
| 8185126
| IS 616 (2017) |
Audio, video and similar electronic apparatus - Safety requirements (Fifth Revision) |
-- |
40000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 5(Marking and instructions) |
- |
3000 |
|
- |
| 7(Heating under normal operating conditions) |
- |
4000 |
|
- |
| 8(Constructional requirements with regard to the protection against electric shock) |
- |
4000 |
|
- |
| 9(Electric shock hazard under normal operating conditions) |
- |
4000 |
|
- |
| 10(Insulation requirements) |
- |
4000 |
|
- |
| 11(Fault conditions) |
- |
4000 |
|
- |
| 12(Mechanical strength) |
- |
4000 |
|
- |
| 13(CLEARANCES and CREEPAGE DISTANCES) |
- |
2000 |
|
- |
| 14(Components) |
- |
1000 |
|
- |
| 15(TERMINALS) |
- |
2000 |
|
- |
| 16(External flexible cords) |
- |
2000 |
|
- |
| 17(Electrical connections and mechanical fixings) |
- |
2000 |
|
- |
| 19(Stability and mechanical hazards) |
- |
2000 |
|
- |
| 20(Resistance to fire) |
- |
2000 |
|
- |
| 15(Internal wires and power cords) |
- |
0 |
|
- |
| 16.3b(Cord Bending Test) |
- |
0 |
|
- |
| 20.2.4(Printed Boards) |
- |
0 |
|
- |
| 3(General requirements) |
- |
0 |
|
- |
| 4(General test conditions) |
- |
0 |
|
- |
| Annex-A(Additional requirements for apparatus with protection against splashing water) |
- |
0 |
|
- |
| Annex-B(Apparatus to be connected to the TELECOMMUNICATION NETWORKS) |
- |
0 |
|
- |
| Annex-L(Additional requirements for electronic flash apparatus for photographic purposes) |
- |
0 |
|
- |
| Cl.5.1 of Cl.5(General requirements) |
- |
0 |
|
- |
| Cl.5.1-i) of Cl.5(Comprehensible and easily discernible) |
- |
0 |
|
- |
| Cl.5.1-ii) of Cl.5(Permanent durability against water and petroleum spirit) |
- |
0 |
|
- |
| Cl.5.2 of Cl.5(Identification and supply ratings) |
- |
0 |
|
- |
| Cl.5.2 a) of Cl.5(Identification, maker) |
- |
0 |
|
- |
| Cl.5.2 b) of Cl.5(Model number or type reference) |
- |
0 |
|
- |
| Cl.5.2 d) of Cl.5(Nature of supply) |
- |
0 |
|
- |
| Cl.5.2 e) of Cl.5(Rated supply voltage) |
- |
0 |
|
- |
| Cl.5.2 f) of Cl.5(Mains frequency if safety dependant) |
- |
0 |
|
- |
| Cl.5.2 g) of Cl.5(Rated current or power consumption for apparatus supplied by supply apparatus for general use, on apparatus or in instruction manual: Measured current or power consumption: Deviation % (max 10%):) |
- |
0 |
|
- |
| Cl.5.2 h) of Cl.5(Rated current or power consumption for apparatus intended for connection to an a.c. mains supply:Measured current or power consumption for Television set: Deviation % (max 10%):) |
- |
0 |
|
- |
| Cl.5.2 h)-i) of Cl.5(appliance coupler for Class I is used for Class II equipment with functional earth connection, the requirements of Clause 15 and Clause 16 related to Class I construction shall be applied up to the connecting point of the protective(earthing) conductor to the functional earth.) |
- |
0 |
|
- |
| Cl.5.2 h)-ii) of Cl.5(Graphical symbols placed on the apparatus, whether required by this standard or not, shall be in accordance with IEC 60417 or ISO 3864-2 or ISO 7000, if available. In the absence of suitable symbols, the manufacturer may design specific graphical symbols.) |
- |
0 |
|
- |
| Cl.5.2 h)-iii) of Cl.5(Care shall be taken so that additional markings and instructions not required by this standard do not contradict the markings and instructions required by this standard . Symbols placed on the Equipment shall be explained in the user manual.) |
- |
0 |
|
- |
| Cl.5.3 of Cl.5(Terminals) |
- |
0 |
|
- |
| Cl.5.3a) of Cl.5(Earth terminal) |
- |
0 |
|
- |
| Cl.5.3b) of Cl.5(Hazardous live terminals) |
- |
0 |
|
- |
| Cl.5.3c) of Cl.5(Markings on supply output terminals) |
- |
0 |
|
- |
| Cl.5.4 of Cl.5(Caution marking) |
- |
0 |
|
- |
| Cl.5.4a) of Cl.5(Use of triangle with exclamation mark) |
- |
0 |
|
- |
| Cl.5.4b) of Cl.5(Marking on loudspeaker grille, IEC 60417-5036) |
- |
0 |
|
- |
| Cl.5.4c) of Cl.5(User-replaceable coin / button cell battery marking) |
- |
0 |
|
- |
| Cl.5.5 of Cl.5(Instructions) |
- |
0 |
|
- |
| Cl.5.5 of Cl.5(Instructions) |
- |
0 |
|
- |
| Cl.5.5 of Cl.5(Instructions) |
- |
0 |
|
- |
| Cl.5.5.1 of Cl.5.5(Safety relevant information) |
- |
0 |
|
- |
| Cl.5.5.2 a) of Cl.5.5(Mains powered equipment not exposed to dripping or splashing. Warning concerning objects filled with liquid, etc.) |
- |
0 |
|
- |
| Cl.5.5.2 b) of Cl.5.5(Hazardous live terminals, instructions for wiring) |
- |
0 |
|
- |
| Cl.5.5.2 c) of Cl.5.5(Instructions for replacing lithium battery) |
- |
0 |
|
- |
| Cl.5.5.2 d) of Cl.5.5(Class I earth connection warning) |
- |
0 |
|
- |
| Cl.5.5.2 e) of Cl.5.5(Instructions for multimedia system connection) |
- |
0 |
|
- |
| Cl.5.5.2 f) of Cl.5.5(Special stability warning for attachment of the apparatus to the floor/wall) |
- |
0 |
|
- |
| Cl.5.5.2 g) of Cl.5.5(Warning: battery exposure to heat) |
- |
0 |
|
- |
| Cl.5.5.2 h) of Cl.5.5(Warning: protective film on CRT face) |
- |
0 |
|
- |
| Cl.5.5.2 i) of Cl.5.5("Warning: Non-floor standing TV
>7kg") |
- |
0 |
|
- |
| Cl.5.5.2 j) of Cl.5.5("Warning: User replaceable coin
/ button cell battery") |
- |
0 |
|
- |
| Cl.5.5.3 (a-b) of Cl.5.5(Disconnect device: plug/coupler or all-pole mains switch location, accessibility and markings) |
- |
0 |
|
- |
| Cl.5.5.3 c) of Cl.5.5(Instructions for permanently connected equipment) |
- |
0 |
|
- |
| Cl.5.5.3 c) i) of Cl.5.5(Marking, signal lamps or similar for completely disconnection from the mains) |
- |
0 |
|
- |
| Cl.7.1 of Cl.7(General) |
- |
0 |
|
- |
| "Cl.7.1.1 of Cl.7.1 Table-3"(Requirements) |
- |
0 |
|
- |
| "Cl.7.1.2 of Cl.7.1 Table-3"(Accessible parts) |
- |
0 |
|
- |
| "Cl.7.1.3 of Cl.7.1 Table-3"(Parts, other than windings and printed boards, providing electrical insulation) |
- |
0 |
|
- |
| "Cl.7.1.4 of Cl.7.1 Table-3"(Parts acting as a support or a mechanical barrier) |
- |
0 |
|
- |
| "Cl.7.1.5 of Cl.7.1 Table-3"(Windings) |
- |
0 |
|
- |
| "Cl.7.1.6 of Cl.7.1 Table-3"(Parts not subject to a limit under7.1.1 to 7.1.4) |
- |
0 |
|
- |
| Cl.7.2 of Cl.7(Softening temperature of insulating material supporting parts conductively connected to the mains carrying a current> 0.2 A, shall be at least 150ºC) |
- |
0 |
|
- |
| Cl.8.1 of Cl.8(Conductive parts covered by lacquer, paper, untreated textile oxide films and beads etc. considered to be bare*) |
- |
0 |
|
- |
| Cl.8.2 of Cl.8(No shock hazard when changing voltage setting device, fuse-links or handling drawers etc.) |
- |
0 |
|
- |
| Cl.8.3 of Cl.8(Insulation of hazardous live parts not provided by hygroscopic material) |
- |
0 |
|
- |
| Cl.8.4 of Cl.8(No risk of electric shock from accessible parts or from parts rendered accessible following the removal of a cover which can be removed by hand) |
- |
0 |
|
- |
| Cl.8.5 of Cl.8(Class I apparatus*) |
- |
0 |
|
- |
| Cl.8.5 i) of Cl.8(Basic insulation between hazardous live parts and earthed accessible parts *) |
- |
0 |
|
- |
| Cl.8.5 ii) of Cl.8(Resistors bridging basic insulation shall complying with 14.1 a) *) |
- |
0 |
|
- |
| Cl.8.5 iii) of Cl.8(Capacitors bridging basic insulation shall complying with 14.2.1 a) *) |
- |
0 |
|
- |
| Cl.8.5 iv) of Cl.8(Protective earthing terminal *) |
- |
0 |
|
- |
| Cl.8.6 of Cl.8(Class II apparatus) |
- |
0 |
|
- |
| Cl.8.6 a) of Cl.8(Basic and supplementary insulation between hazardous live parts and accessible parts *) |
- |
0 |
|
- |
| Cl.8.6 b) of Cl.8(Reinforced insulation between hazardous live parts and accessible parts *) |
- |
0 |
|
- |
| Cl.8.7 of Cl.8(Components bridging insulation) |
- |
0 |
|
- |
| Cl.8.7 i) of Cl.8(Basic insulation bridged by components complying with 14.4.5.3) |
- |
0 |
|
- |
| Cl.8.7 ii) of Cl.8(Components bridging basic, supplementary, double or reinforced insulation complying with 14.2 a) or 14.4) |
- |
0 |
|
- |
| Cl.8.7 iii) of Cl.8(Basic and supplementary insulation each being bridged by a capacitor or RC-unit complying with 14.3.2 a)) |
- |
0 |
|
- |
| Cl.8.7 iv) of Cl.8(Double or reinforced insulation being bridged with 2 capacitors or RC-units in series complying with 14.3.2 a)) |
- |
0 |
|
- |
| Cl.8.7 v) of Cl.8(Double or reinforced insulation being bridged with a single capacitor or RC-unit complying with 14.3.2 b)) |
- |
0 |
|
- |
| Cl.8.8 of Cl.8(Insulation thickness and thin sheet materials) |
- |
0 |
|
- |
| Cl.8.8 i) of Cl.8(Basic or supplementary insulation > 0,4 mm (mm)*) |
- |
0 |
|
- |
| Cl.8.8 ii) of Cl.8(Reinforced insulation > 0,4 mm (mm) *) |
- |
0 |
|
- |
| Cl.8.8 iii) of Cl.8(Thin sheet material used inside the equipment) |
- |
0 |
|
- |
| Cl.8.8 iv) of Cl.8(Basic or supplementary insulation, atleast two layers, each meeting10.4) |
- |
0 |
|
- |
| Cl.8.8 v) of Cl.8(Basic or supplementary insulation, three layers any two of which meet10.4) |
- |
0 |
|
- |
| Cl.8.8 vi) of Cl.8(Reinforced insulation, two layers each of which meet 10.4) |
- |
0 |
|
- |
| Cl.8.9 of Cl.8(Adequate insulation between internal hazardous live conductors and accessible parts, or between internal hazardous live parts and conductors connected to accessible parts) |
- |
0 |
|
- |
| Cl.8.10 of Cl.8(Double insulation between accessible parts and conductors connected to the mains) |
- |
0 |
|
- |
| Cl.8.10 of Cl.8(Double insulation between conductors connected to accessible parts and parts connected to the mains) |
- |
0 |
|
- |
| Cl.8.11 of Cl.8(Detaching of wires) |
- |
0 |
|
- |
| Cl.8.11 i) of Cl.8(Noun due reduction of creepage or clearance distances if wires become detached) |
- |
0 |
|
- |
| Cl.8.11 ii) of Cl.8(Vibration test carried out) |
- |
0 |
|
- |
| Cl.8.12 of Cl.8(Adequate fastening of windows, lenses, lamp covers etc. (pull test 20 N for 10 s)) |
- |
0 |
|
- |
| Cl.8.13 of Cl.8(Adequate fastening of windows, lenses, lamp covers etc. (pull test 20 N for 10 s)) |
- |
0 |
|
- |
| Cl.8.14 of Cl.8(No risk of damage to the insulation of internal wiring due to hot parts or sharp edges) |
- |
0 |
|
- |
| Cl.8.15 of Cl.8(Only special supply equipment can be used*) |
- |
0 |
|
- |
| Cl.8.16 of Cl.8(Insulated winding wire without additional interleaved insulation) |
- |
0 |
|
- |
| Cl.8.18 of Cl.8(Disconnection from the mains) |
- |
0 |
|
- |
| Cl.8.18 i) of Cl.8(Disconnect device used in apparatus) |
- |
0 |
|
- |
| Cl.8.18 ii) of Cl.8(All-pole switch or circuit breaker with >3mm contact separation.) |
- |
0 |
|
- |
| Cl.8.18 iii) of Cl.8(Mains switch ON indication *) |
- |
0 |
|
- |
| Cl.8.19 of Cl.8(Switch not fitted in the mains cord *) |
- |
0 |
|
- |
| Cl.8.20 of Cl.8(Bridging components comply with clause 14) |
- |
0 |
|
- |
| Cl.8.21 of Cl.8(Non-separable thin sheet material) |
- |
0 |
|
- |
| Cl.9.1 of Cl.9(Testing on the outside) |
- |
0 |
|
- |
| Cl.9.1.1 of Cl.9.1(Requirements) |
- |
0 |
|
- |
| Cl.9.1.1 i) of Cl.9.1(Accessible parts shall not be hazardous live) |
- |
0 |
|
- |
| Cl.9.1.1 ii) of Cl.9.1(Inaccessible terminals are not accessible or comply with relevant requirements) |
- |
0 |
|
- |
| Cl.9.1.1 iii) of Cl.9.1(For voltages >1000 V ac or >1500 V dc complies with clause 13.3.1 for basic insulation) |
- |
0 |
|
- |
| Cl.9.1.1.2 of Cl.9.1.1(Determination of hazardous live parts) |
- |
0 |
|
- |
| Cl.9.1.1.2 a) of Cl.9.1.1(Open circuit voltages) |
- |
0 |
|
- |
| Touch current measured from terminal devices using the network in annex D(Touch current measured from terminal devices using the network in annex D) |
- |
0 |
|
- |
| Cl.9.1.1.2 c) of Cl.9.1.1(The charge exceeds 45 μC) |
- |
0 |
|
- |
| Cl.9.1.1.2 d) of Cl.9.1.1(Energy of discharge not exceeding 350 mJ) |
- |
0 |
|
- |
| Cl.9.1.1.3 of Cl.9.1.1(Test with test finger and test probe) |
- |
0 |
|
- |
| Cl.9.1.2 of Cl.9.1(Shafts of operating knobs, handles, levers and the like) |
- |
0 |
|
- |
| Cl.9.1.3 of Cl.9.1(Openings ofthe enclosure) |
- |
0 |
|
- |
| Cl.9.1.4 of Cl.9.1(Terminals) |
- |
0 |
|
- |
| Cl.9.1.4 i) of Cl.9.1(Terminals) |
- |
0 |
|
- |
| Cl.9.1.4 ii) of Cl.9.1(Terminals) |
- |
0 |
|
- |
| Cl.9.1.5 of Cl.9.1(Pre-set controls) |
- |
0 |
|
- |
| Cl.9.1.6 of Cl.9.1(Withdrawal of the mains plug:) |
- |
0 |
|
- |
| Cl.9.1.6 i) of Cl.9.1(Withdrawal of the mains plug:) |
- |
0 |
|
- |
| Cl.9.1.6 ii) of Cl.9.1(Withdrawal of the mains plug:) |
- |
0 |
|
- |
| Cl.9.1.6 iii) of Cl.9.1(Withdrawal of the mains plug:) |
- |
0 |
|
- |
| Cl.9.1.7 of Cl.9.1(Resistance to external forces) |
- |
0 |
|
- |
| Cl.9.1.7 a) of Cl.9.1(Resistance to external forces) |
- |
0 |
|
- |
| Cl.9.1.7 b) of Cl.9.1(Resistance to external forces) |
- |
0 |
|
- |
| Cl.9.1.7 c) of Cl.9.1(Resistance to external forces) |
- |
0 |
|
- |
| Cl.9.2 of Cl.9(Removal of protective covers) |
- |
0 |
|
- |
| Cl.10.2 of Cl.10(Surge Test) |
- |
0 |
|
- |
| Cl.10.2 a) of Cl.10(Surge Test) |
- |
0 |
|
- |
| Cl.10.2 b) of Cl.10(Surge Test) |
- |
0 |
|
- |
| Cl.10.2 b) (i) of Cl.10(Surge Test) |
- |
0 |
|
- |
| Cl.10.2 b) (ii) of Cl.10(Surge Test) |
- |
0 |
|
- |
| Cl.10.2 b) (iii) of Cl.10(Surge Test) |
- |
0 |
|
- |
| Cl.10.3 of Cl.10(Humidity treatment) |
- |
0 |
|
- |
| Cl.10.4 of Cl.10(Insulation resistance and dielectric strength) |
- |
0 |
|
- |
| Cl.10.4.1 of Cl.10.4(Insulation of the insulating materials) |
- |
0 |
|
- |
| Cl.10.4.2 of Cl.10.4(Between parts of different polarity directly connected to the mains
Between parts of different polarity directly connected to the mains) |
- |
0 |
|
- |
| Cl.10.4.2 i) of Cl.10.4(Between parts separated by BASIC or SUPPLEMENTARY insulation) |
- |
0 |
|
- |
| Cl.10.4.2 ii) of Cl.10.4(Between parts separated by REINFORCED insulation) |
- |
0 |
|
- |
| Cl.11.1 of Cl.11(Electric Shock Hazard) |
- |
0 |
|
- |
| Cl.11.1 a) of Cl.11(Electric Shock Hazard) |
- |
0 |
|
- |
| Cl.11.1 b) of Cl.11(Electric Shock Hazard) |
- |
0 |
|
- |
| Cl.11.2 of Cl.11(Heating) |
- |
0 |
|
- |
| Cl.11.2.1 of Cl.11.2(Requirements) |
- |
0 |
|
- |
| Cl.11.2.1 i) of Cl.11.2(No danger of fire to the surroundings) |
- |
0 |
|
- |
| Cl.11.2.1 ii) of Cl.11.2(Safety not impaired by abnormal heat) |
- |
0 |
|
- |
| Cl.11.2.1 of Cl.11.2(Flames extinguish within 10 seconds) |
- |
0 |
|
- |
| Cl.11.2.1 of Cl.11.2(No hazard from softening solder) |
- |
0 |
|
- |
| Cl.11.2.1 of Cl.11.2(Soldered terminations not used as protective mechanism) |
- |
0 |
|
- |
| Cl.11.2.2 of Cl.11.2(Measurement of temperature rises) |
- |
0 |
|
- |
| Cl.11.2.3 of Cl.11.2(Accessible parts) |
- |
0 |
|
- |
| Cl.11.2.4 of Cl.11.2(Parts, other than windings and printed boards, providing electrical insulation) |
- |
0 |
|
- |
| Cl.11.2.5 of Cl.11.2(Parts acting as a support or a mechanical barrier) |
- |
0 |
|
- |
| Cl.11.2.6 of Cl.11.2(Windings ) |
- |
0 |
|
- |
| Cl.11.2.7 of Cl.11.2(Printed boards) |
- |
0 |
|
- |
| Cl.11.2.7 i) of Cl.11.2(Printed boards) |
- |
0 |
|
- |
| Cl.11.2.7 i) a) of Cl.11.2(Printed boards) |
- |
0 |
|
- |
| Cl.11.2.7 i) b) of Cl.11.2(Printed boards) |
- |
0 |
|
- |
| Cl.11.2.7 ii) of Cl.11.2(Printed boards) |
- |
0 |
|
- |
| Cl.11.2.7 iii) of Cl.11.2(Printed boards) |
- |
0 |
|
- |
| Cl.11.2.8 of Cl.11.2(Parts not subject to a limit under7.1.1 to 7.1.4) |
- |
0 |
|
- |
| Cl.12.1.1 of Cl.12.1(Requirements) |
- |
0 |
|
- |
| Cl.12.1.2 of Cl.12.1(Bump test ) |
- |
0 |
|
- |
| Cl.12.1.3 of Cl.12.1(Vibration test) |
- |
0 |
|
- |
| Cl.12.1.4 of Cl.12.1(Impact test) |
- |
0 |
|
- |
| Cl.12.1.4 i) of Cl.12.1(Impact test) |
- |
0 |
|
- |
| Cl.12.1.4 ii) of Cl.12.1(Impact test) |
- |
0 |
|
- |
| Cl.12.1.5 of Cl.12.1(Drop test) |
- |
0 |
|
- |
| Cl.12.1.6 of Cl.12.1(Stress relief test) |
- |
0 |
|
- |
| Cl.12.2 of Cl.12(Fixing of actuating elements) |
- |
0 |
|
- |
| Cl.12.3 of Cl.12(Remote control devices held in hand) |
- |
0 |
|
- |
| Cl.12.4 of Cl.12(Drawers ) |
- |
0 |
|
- |
| Cl.12.5 of Cl.12(Antenna coaxial sockets mounted on the apparatus) |
- |
0 |
|
- |
| Cl.12.5 a) of Cl.12(Endurance test,) |
- |
0 |
|
- |
| Cl.12.5 b) of Cl.12(Impact test,) |
- |
0 |
|
- |
| Cl.12.5 c) of Cl.12(Torque test) |
- |
0 |
|
- |
| Cl.12.6 of Cl.12(Telescoping or rod antennas) |
- |
0 |
|
- |
| Cl.12.6.1 of Cl.12.6(General requirements) |
- |
0 |
|
- |
| Cl.12.6.1 i) of Cl.12.6(General requirements) |
- |
0 |
|
- |
| Cl.12.6.2 of Cl.12.6(Physical securement) |
- |
0 |
|
- |
| Cl.12.7 of Cl.12(Apparatus containing coin / button cell batteries) |
- |
0 |
|
- |
| Cl.12.7.1 of Cl.12.7(Coin/button cell batteries with a diameter of 32 mm or less.) |
- |
0 |
|
- |
| Cl.12.7.2 of Cl.12.7(Construction requirementss) |
- |
0 |
|
- |
| Cl.12.7.3 of Cl.12.7(Tests) |
- |
0 |
|
- |
| Cl.12.7.3.2 of Cl.12.7.3(Stress relief test) |
- |
0 |
|
- |
| Cl.12.7.3.3 of Cl.12.7.3(Battery replacement test) |
- |
0 |
|
- |
| Cl.12.7.3.4 of Cl.12.7.3(Drop test) |
- |
0 |
|
- |
| Cl.12.7.3.5 of Cl.12.7.3(Impact test) |
- |
0 |
|
- |
| Cl.12.7.3.6 of Cl.12.7.3(Crush test) |
- |
0 |
|
- |
| Cl.12.7.4 of Cl.12.7(Compliance) |
- |
0 |
|
- |
| Cl.13.1 of Cl.13(General) |
- |
0 |
|
- |
| Cl.13.2 of Cl.13(Determination of Working voltage) |
- |
0 |
|
- |
| Cl.13.3 of Cl.13(Clearances) |
- |
0 |
|
- |
| Cl.13.3.1 of Cl.13.3(General) |
- |
0 |
|
- |
| Cl.13.3.2 of Cl.13.3(Clearances in circuits conductively connected to the mains) |
- |
0 |
|
- |
| Cl.13.3.3 of Cl.13.3(Clearances in circuits not conductively connected to the mains) |
- |
0 |
|
- |
| Cl.13.3.4 of Cl.13(Measurement of transient voltages) |
- |
0 |
|
- |
| Cl.13.4 a) of Cl.13(Creepage distances ) |
- |
0 |
|
- |
| Cl.13.4 b) of Cl.13(Creepage distances ) |
- |
0 |
|
- |
| Cl.13.4 c) of Cl.13(Creepage distances ) |
- |
0 |
|
- |
| Cl.13.6 a) of Cl.13(Jointed insulation ) |
- |
0 |
|
- |
| Cl.13.6 b) of Cl.13(Jointed insulation ) |
- |
0 |
|
- |
| Cl.13.6 c) of Cl.13(Jointed insulation ) |
- |
0 |
|
- |
| Cl.13.6 d) of Cl.13(Jointed insulation ) |
- |
0 |
|
- |
| Cl.13.7 of Cl.13(Enclosed and sealed parts) |
- |
0 |
|
- |
| Cl.13.8 of Cl.13(Parts filled with insulating compound, meeting the requirements of 8.8) |
- |
0 |
|
- |
| Cl.15.1 of Cl.15(Plugs and Sockets*) |
- |
0 |
|
- |
| Cl.15.1.1 of Cl.15.1(Plugs and Sockets*) |
- |
0 |
|
- |
| Cl.15.1.1 i) of Cl.15.1(Plugs and Sockets*) |
- |
0 |
|
- |
| Cl.15.1.1 ii) of Cl.15.1(Plugs and Sockets*) |
- |
0 |
|
- |
| Cl.15.1.2 of Cl.15.1(Design of connectors other than for mains power *) |
- |
0 |
|
- |
| Cl.15.1.2 i) of Cl.15.1(Design of sockets with symbol of 5.3 b) design *) |
- |
0 |
|
- |
| Cl.15.1.3 of Cl.15.1(Design of terminals and connectors used in output circuits of supply apparatus*) |
- |
0 |
|
- |
| Cl.15.2 of Cl.15(Provisions for protective earthing) |
- |
0 |
|
- |
| Cl.15.2 i) of Cl.15(Provisions for protective earthing) |
- |
0 |
|
- |
| Cl.15.2 ii) of Cl.15(Provisions for protective earthing) |
- |
0 |
|
- |
| Cl.15.2 iii) of Cl.15(Provisions for protective earthing) |
- |
0 |
|
- |
| Cl.15.2 iv) of Cl.15(Provisions for protective earthing) |
- |
0 |
|
- |
| Cl.15.2 v) of Cl.15(Provisions for protective earthing) |
- |
0 |
|
- |
| Cl.15.3 of Cl.15(Terminals for external flexible cords and for permanent connection to the mains supply*) |
- |
0 |
|
- |
| Cl.15.3.1 of Cl.15.3(Adequate terminals for connection of permanent wiring*) |
- |
0 |
|
- |
| Cl.15.3.2 of Cl.15.3(Reliable connection of non-detachable cords) |
- |
0 |
|
- |
| Cl.15.3.2 i) of Cl.15.3(Not soldered to conductors of a printed circuit board) |
- |
0 |
|
- |
| Cl.15.3.2 ii) of Cl.15.3(Adequate clearances and creepage distances between connections should a wire break away) |
- |
0 |
|
- |
| Cl.15.3.2 iii) of Cl.15.3(Wire secured by additional means to the conductor) |
- |
0 |
|
- |
| Cl.15.3.3 of Cl.15.3(Screws and nuts clamping conductors have adequate threads: ISO 261, ISO 262 or similar*) |
- |
0 |
|
- |
| Cl.15.3.4 of Cl.15.3(Conductors adequately fixed (two independent fixings) *) |
- |
0 |
|
- |
| Cl.15.3.5 of Cl.15.3(Terminals allow connection of conductors having appropriate cross-sectional area) |
- |
0 |
|
- |
| Cl.15.3.6 of Cl.15.3(Terminals to 15.3.3 have sizes required by table 16) |
- |
0 |
|
- |
| Cl.15.3.7 of Cl.15.3(Terminals clamp conductors between metal and have adequate pressure) |
- |
0 |
|
- |
| Cl.15.3.7 i) of Cl.15.3(Terminals designed to avoid conductor slipping out when tightened) |
- |
0 |
|
- |
| Cl.15.3.7 ii) of Cl.15.3(Terminals adequately fixed when tightened or loosened (no loosening, wiring not stressed, distances not reduced)) |
- |
0 |
|
- |
| Cl.15.3.8 of Cl.15.3(Terminals carrying a current more than) |
- |
0 |
|
- |
| Cl.15.3.8 i) of Cl.15.3(0.2 A, contact pressure not transmitted by insulating material except ceramic*) |
- |
0 |
|
- |
| Cl.15.3.9 of Cl.15.3(Termination of non-detachable cords: wires terminated near to each other) |
- |
0 |
|
- |
| Cl.15.3.9 i) of Cl.15.3(Terminals located and shielded: test with 8 mm strand) |
- |
0 |
|
- |
| Cl.15.4 of Cl.15(Devices forming a part of the mains plug*) |
- |
0 |
|
- |
| Cl.15.4.1 of Cl.15.4(No undue strain on mains socket-outlets.) |
- |
0 |
|
- |
| Cl.15.4.1 i) of Cl.15.4(Device shall be tested on the equipment as per Fig.11: Torque to be applied : 0.25 Nm (Max)) |
- |
0 |
|
- |
| Cl.15.4.2 of Cl.15.4(Device complies with standard for dimensions of mains plugs) |
- |
0 |
|
- |
| Cl.15.4.3 of Cl.15.4(Device has adequate mechanical strength (tests a,b,c)) |
- |
0 |
|
- |
| Cl.16.1 a) of Cl.16(Mains supply flexible cords shall be sheathed type, complying with IEC 60227 for PVC cords or as per IEC 60245 for synthetic rubber cords) |
- |
0 |
|
- |
| Cl.16.1 b) of Cl.16(Non-detachable cords for Class I have green/yellow core for protective earth) |
- |
0 |
|
- |
| Cl.16.2 of Cl.16(Mains cords conductors shall have a nominal cross-sectional area not less than the values given in Table 18, for rated current consumption of the apparatus) |
- |
0 |
|
- |
| Cl.16.3 a) of Cl.16(Flexiblecordsnotcomplyingwith16.1, used for interconnections between separate units of equipment used in combination and carrying hazardous live voltages, have adequate dielectric strength as perCl.10.3) |
- |
0 |
|
- |
| Cl.16.4 of Cl.16(Flexible cords used for connection between equipment have adequate cross-sectional areas to avoid temperature rise under normal and fault conditions) |
- |
0 |
|
- |
| Cl.16.5 a) of Cl.16(Adequate strain relief on external flexible cords) |
- |
0 |
|
- |
| Cl.16.5 b) of Cl.16(Not possible to push cord back into equipment) |
- |
0 |
|
- |
| Cl.16.5 c) of Cl.16(Strain relief device unlikely to damage flexible cord) |
- |
0 |
|
- |
| Cl.16.5 d) of Cl.16(For mains cords of Class I equipment, hazardous live conductors become taut before earth conductor) |
- |
0 |
|
- |
| Cl.16.6 of Cl.16(Apertures for external flexible cord: no risk of damage to the cord during assembly or movement in use) |
- |
0 |
|
- |
| Cl.16.7 a) of Cl.16(Transportable apparatus fitted with detachable cord sets with appliance inlet as perIEC60320-1 or) |
- |
0 |
|
- |
| Cl.16.7 b) of Cl.16(Transportable apparatus shall have a means of stowage to protect the cord) |
- |
0 |
|
- |
| 17.1 a) of Cl.17(Screws are loosened and then tightened with a torque according to table20) |
- |
0 |
|
- |
| Cl.17.1 b) of Cl.17(5 times in the case of screws operating in a thread of metal) |
- |
0 |
|
- |
| Cl.17.1 c) of Cl.17(10 times in the case of screws operating in wood or in a thread in insulating material:) |
- |
0 |
|
- |
| Cl.17.2 of Cl.17(Correct introduction of screws into female threads in non-metallic material) |
- |
0 |
|
- |
| Cl.17.3 a) of Cl.17(Screws or other fixing devices intended to fix Covers, legs, stands or the like, shall be captive in order to prevent replacement during servicing by screws or other fixing devices……) |
- |
0 |
|
- |
| Cl.17.3 b) of Cl.17(Non-captive fixing screws: no hazard when replaced by a screw whose length is 10 times its diameter) |
- |
0 |
|
- |
| Cl.17.4 of Cl.17(No loosening of conductive parts carrying a current > 0.2 A) |
- |
0 |
|
- |
| Cl.17.5 of Cl.17(Contact pressure not transmitted through plastic other than ceramic for connections carrying a current > 0.2 A*) |
- |
0 |
|
- |
| Cl.17.6 of Cl.17(Stranded conductors of flexible supply cords carrying a current > 0.2 A with screw terminals not consolidated by solder *) |
- |
0 |
|
- |
| Cl.17.7 of Cl.17(Cover fixing devices other than screws have adequate strength and their positioning is unambiguous) |
- |
0 |
|
- |
| Cl.17.8 of Cl.17(Detachable legs or stands supplied by the manufacturer of the apparatus shall be delivered with the relevant fixing means *) |
- |
0 |
|
- |
| Cl.17.9 a) of Cl.17(Internal pluggable connections, affecting safety, unlikely to become disconnected) |
- |
0 |
|
- |
| Cl.17.9 b) of Cl.17(By applying a 2N pull force in any direction to the connection, in case of doubt) |
- |
0 |
|
- |
| Cl.19.1 of Cl.19(Stability and mechanical hazards) |
- |
0 |
|
- |
| Cl.19.1 of Cl.19(Stability requirements) |
- |
0 |
|
- |
| Cl.19.1 i) of Cl.19(Stability requirements) |
- |
0 |
|
- |
| Cl.19.2 of Cl.19(Test at 10° to the horizontal) |
- |
0 |
|
- |
| Cl.19.3 of Cl.19(Vertical force test ) |
- |
0 |
|
- |
| Cl.19.4 of Cl.19(Horizontal force test) |
- |
0 |
|
- |
| Cl.19.5 of Cl.19(Test of edges and corners) |
- |
0 |
|
- |
| Cl.19.6 of Cl.19(Mechanical strength of glass) |
- |
0 |
|
- |
| Cl.19.6.1 of Cl.19.6(Requirements) |
- |
0 |
|
- |
| Cl.19.6.2 of Cl.19.6(Fragmentation test) |
- |
0 |
|
- |
| Cl.19.7 of Cl.19(Wall or ceiling mounting means) |
- |
0 |
|
- |
| Cl.19.7.1 of Cl.19..7(Requirements) |
- |
0 |
|
- |
| Cl.19.7.3 of Cl.19.7(Compliance) |
- |
0 |
|
- |
| Cl.20.1 of Cl.20(Requirements) |
- |
0 |
|
- |
| Cl.20.2 of Cl.20(Electrical components and mechanical parts) |
- |
0 |
|
- |
| Cl.20.2.1 a) of Cl.20.2(Exemption for components contained in an enclosure of material V-0 to IEC60695- 11-10 with openings not exceeding 1 mm in width) |
- |
0 |
|
- |
| Cl.20.2.1 b) of Cl.20.2(Exemption for small components) |
- |
0 |
|
- |
| Cl.20.2.2 of Cl.20.2(Electrical components ) |
- |
0 |
|
- |
| Cl.20.2.3 of Cl.20.2(Internal wiring) |
- |
0 |
|
- |
| Cl.20.2.4 of Cl.20.2(Printed boards) |
- |
0 |
|
- |
| Cl.20.2.4 i) of Cl.20.2(Printed boards) |
- |
0 |
|
- |
| Cl.20.2.5 of Cl.20.2(Components and parts not covered by 20.2.2, 20.2.3 and 20.2.4) |
- |
0 |
|
- |
| Cl.20.2.5 i) of Cl.20.2(Components and parts not covered by 20.2.2, 20.2.3 and 20.2.4) |
- |
0 |
|
- |
| Cl.20.2.5 ii) of Cl.20.2(Components and parts not covered by 20.2.2, 20.2.3 and 20.2.4) |
- |
0 |
|
- |
| Cl.20.3 of Cl.20(Fire enclosure*) |
- |
0 |
|
- |
| Cl.20.3.1 of Cl.20.3(Fire enclosure*) |
- |
0 |
|
- |
| Cl.20.3.2 of Cl.20.3(Fire enclosure*) |
- |
0 |
|
- |
| Cl.20.3.3 of Cl.20.3(Fire enclosure*) |
- |
0 |
|
- |
|
05 May, 2028 |
- Exclusions : 6 (Hazardous radiations), 18 (Mechanical strength of picture tubes and protection against the effects of implosion), 8.16/ H 2.2/ H 2.3 (Requirements for insulated winding wires for use without additional interleaved insulation), 14 (Components), 8.16 (Wound Component) |
| 7713 |
Bombay Textiles Research Association (BTRA), Mumbai
| 7130206
| IS 758 (2023) |
MEDICAL TEXTILES � COTTON ABSORBENT GAUZE � SPECIFICATION ( Fifth Revision of IS 758 ) |
- |
8280 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl-4.2, Table 1 (i)("Count of yarn (for guidance only)
(a)-Warp") |
- |
510 |
|
- |
| Cl-4.2, Table 1 (i)("Count of yarn (for guidance only)
(b)-Weft") |
- |
0 |
|
- |
| Cl-4.2, Table 1 (ii)(Threads/dm) |
- |
510 |
|
- |
| Cl-4.2, Table 1 (iii)(Mass, g/m2) |
- |
510 |
|
- |
| Cl-4.2, Table 1 (iv)(Length, m) |
- |
510 |
|
- |
| Cl-4.2, Table 1 (v)(Width, cm) |
- |
510 |
|
- |
| Cl-3.2 a("Cloth- The fabric shall be reasonably
free from Odour") |
- |
1010 |
|
- |
| Cl-4.1(Fibre Identification) |
- |
760 |
|
- |
| Cl-4.2, Table 1 (vi)(Absorbency) |
- |
760 |
|
- |
| Cl-4.2, Table 1 (vii)(pH value of aqueous extract) |
- |
510 |
|
- |
| Cl-4.2, Table 1 (viii)(Scouring loss, percent) |
- |
1010 |
|
- |
| Cl-4.2, Table 1 (ix)(Freedom from optical whitener) |
- |
760 |
|
- |
| Cl-4.2, Table 1 (x)(Sterility (optional)) |
- |
0 |
|
- |
| Cl.4.2 - Table No 1 - Sl. No.-vi(Absorbency- IS 2369) |
- |
0 |
|
- |
| Cl.4.2 - Table No 1 - Sl. No.-vii(pH value of aqueous extract - IS 1390) |
- |
0 |
|
- |
| Cl.4.2 - Table No 1 - Sl. No.-viii(Scouring loss - IS 1383 (mild method)) |
- |
0 |
|
- |
| Cl.4.2 - Table No 1 - Sl. No.-ix("Freedom from optical whitener
- viewing under ultra-violet light") |
- |
0 |
|
- |
| Medical Textiles — Absorbent Cotton Gauze — Specification (Fifth Revision)(Sterile product) |
- |
0 |
|
- |
| 4.3(Non-sterile product) |
- |
1010 |
|
- |
| Cl-3.2 b("Cloth- The fabric shall be reasonably
free from Defective Selvedge") |
- |
0 |
|
- |
| Cl-3.2 c("Cloth- The fabric shall be reasonably
free from Cracks") |
- |
0 |
|
- |
| Cl-3.2 d("Cloth- The fabric shall be reasonably
free from Double ends") |
- |
0 |
|
- |
| Cl-3.2 e("Cloth- The fabric shall be reasonably
free from Sloughing") |
- |
0 |
|
- |
| Cl-4.2, Table 1 (i)("Count of yarn (for guidance only)
(a)-Warp") |
- |
0 |
|
- |
| Cl-4.2, Table 1 (i)("Count of yarn (for guidance only)
(b)-Weft") |
- |
0 |
|
- |
| Cl-4.2, Table 1 (ii)(Threads/dm) |
- |
0 |
|
- |
| Cl-4.2, Table 1 (iii)(Mass, g/m2) |
- |
0 |
|
- |
| Cl-4.2, Table 1 (iv)(Length, m) |
- |
0 |
|
- |
| Cl-4.2, Table 1 (v)(Width, cm) |
- |
0 |
|
- |
| Cl-3.2 a("Cloth- The fabric shall be reasonably
free from Odour") |
- |
0 |
|
- |
| Cl-4.1(Fibre Identification) |
- |
0 |
|
- |
| Cl-4.2, Table 1 (vi)(Absorbency) |
- |
0 |
|
- |
| Cl-4.2, Table 1 (vii)(pH value of aqueous extract) |
- |
0 |
|
- |
| Cl-4.2, Table 1 (viii)(Scouring loss, percent) |
- |
0 |
|
- |
| Cl-4.2, Table 1 (ix)(Freedom from optical whitener) |
- |
0 |
|
- |
| Cl.4.2 - Table No 1 - Sl. No.-vi(Absorbency- IS 2369) |
- |
0 |
|
- |
| Cl.4.2 - Table No 1 - Sl. No.-vii(pH value of aqueous extract - IS 1390) |
- |
0 |
|
- |
| Cl.4.2 - Table No 1 - Sl. No.-viii(Scouring loss - IS 1383 (mild method)) |
- |
0 |
|
- |
| Cl.4.2 - Table No 1 - Sl. No.-ix("Freedom from optical whitener
- viewing under ultra-violet light") |
- |
0 |
|
- |
| Medical Textiles — Absorbent Cotton Gauze — Specification (Fifth Revision)(Sterile product) |
- |
0 |
|
- |
| 4.3(Non-sterile product) |
- |
0 |
|
- |
| Cl-3.2 b("Cloth- The fabric shall be reasonably
free from Defective Selvedge") |
- |
0 |
|
- |
| Cl-3.2 c("Cloth- The fabric shall be reasonably
free from Cracks") |
- |
0 |
|
- |
| Cl-3.2 d("Cloth- The fabric shall be reasonably
free from Double ends") |
- |
0 |
|
- |
| Cl-3.2 e("Cloth- The fabric shall be reasonably
free from Sloughing") |
- |
0 |
|
- |
| Cl-4.2, Table 1 (i)("Count of yarn (for guidance only)
(a)-Warp") |
- |
- |
|
- |
| Cl-4.2, Table 1 (i)("Count of yarn (for guidance only)
(b)-Weft") |
- |
- |
|
- |
| Cl-4.2, Table 1 (ii)(Threads/dm) |
- |
- |
|
- |
| Cl-4.2, Table 1 (iii)(Mass, g/m2) |
- |
- |
|
- |
| Cl-4.2, Table 1 (iv)(Length, m) |
- |
- |
|
- |
| Cl-4.2, Table 1 (v)(Width, cm) |
- |
- |
|
- |
| Cl-3.2 a("Cloth- The fabric shall be reasonably
free from Odour") |
- |
- |
|
- |
| Cl-4.1(Fibre Identification) |
- |
- |
|
- |
| Cl-4.2, Table 1 (vi)(Absorbency) |
- |
- |
|
- |
| Cl-4.2, Table 1 (vii)(pH value of aqueous extract) |
- |
- |
|
- |
| Cl-4.2, Table 1 (viii)(Scouring loss, percent) |
- |
- |
|
- |
| Cl-4.2, Table 1 (ix)(Freedom from optical whitener) |
- |
- |
|
- |
| Cl.4.2 - Table No 1 - Sl. No.-vi(Absorbency- IS 2369) |
- |
- |
|
- |
| Cl.4.2 - Table No 1 - Sl. No.-vii(pH value of aqueous extract - IS 1390) |
- |
- |
|
- |
| Cl.4.2 - Table No 1 - Sl. No.-viii(Scouring loss - IS 1383 (mild method)) |
- |
- |
|
- |
| Cl.4.2 - Table No 1 - Sl. No.-ix("Freedom from optical whitener
- viewing under ultra-violet light") |
- |
- |
|
- |
| Medical Textiles — Absorbent Cotton Gauze — Specification (Fifth Revision)(Sterile product) |
- |
- |
|
- |
| 4.3(Non-sterile product) |
- |
- |
|
- |
| Cl-3.2 b("Cloth- The fabric shall be reasonably
free from Defective Selvedge") |
- |
- |
|
- |
| Cl-3.2 c("Cloth- The fabric shall be reasonably
free from Cracks") |
- |
- |
|
- |
| Cl-3.2 d("Cloth- The fabric shall be reasonably
free from Double ends") |
- |
- |
|
- |
| Cl-3.2 e("Cloth- The fabric shall be reasonably
free from Sloughing") |
- |
- |
|
- |
|
- |
- Included w.e.f 26.05.2025
Exclusion: Cl-4.2, Table 1 (x) (Sterility (optional)) |
| 7714 |
Alpha Test House Private Limited, Delhi
| 8131026
| IS 16221 : Part 2 (2015) |
Safety of power converters for use in photovoltaic power systems: Part 2 particular requirements for inverters |
- |
204000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4(General Test Requireements) |
- |
1000 |
|
- |
| 5(Marking and documentation) |
- |
5000 |
|
- |
| 6(Environmental requirements and conditions) |
- |
1000 |
|
- |
| 7(Protection against electric shock and energy hazards) |
- |
5000 |
|
- |
| 8(Protection against Mechanical Hazards) |
- |
5000 |
|
- |
| 9(Protection against Fire Hazards) |
- |
5000 |
|
- |
| 10(Protection against Sonic Pressure Hazards) |
- |
5000 |
|
- |
| 11(Protection against Liquid Hazards) |
- |
5000 |
|
- |
| 12(Protection against Chemical Hazards) |
- |
5000 |
|
- |
| 13(Physical Requirements) |
- |
5000 |
|
- |
| 9.1.4.3(Hot flaming oil test) |
- |
5000 |
|
- |
| Clause No. 4.3(Thermal testing) |
- |
10000 |
|
- |
| Clause No. 4.4(Testing in single fault condition) |
- |
10000 |
|
- |
| 4.5(Humidity preconditioning) |
- |
10000 |
|
- |
| 4.6(Backfeed voltage protection) |
- |
5000 |
|
- |
| 4.7(Electrical rating tests) |
- |
3000 |
|
- |
| 4.8(Additional tests for grid interactive inverters) |
- |
5000 |
|
- |
| 4(General Test Requirements) |
- |
1000 |
|
- |
| 5(Marking and documentation) |
- |
5000 |
|
- |
| 6(Environmental requirements and conditions) |
- |
1000 |
|
- |
| 7(Protection against electric shock and energy hazards) |
- |
5000 |
|
- |
| 8(Protection against Mechanical Hazards) |
- |
5000 |
|
- |
| 9(Protection against Fire Hazards) |
- |
5000 |
|
- |
| 10(Protection against Sonic Pressure Hazards) |
- |
5000 |
|
- |
| 11(Protection against Liquid Hazards) |
- |
5000 |
|
- |
| 12(Protection against Chemical Hazards) |
- |
5000 |
|
- |
| 13(Physical Requirements) |
- |
5000 |
|
- |
| 4.4.4.15.1(Fault-tolerance of residual current monitoring) |
- |
5000 |
|
- |
| 4.4.4.15.2(Fault-tolerance of automatic disconnecting means) |
- |
5000 |
|
- |
| 4.4.4.16(Stand-alone inverters – Load transfer test) |
- |
5000 |
|
- |
| 4.4.4.17(Cooling system failure – Blanketing test) |
- |
5000 |
|
- |
| 4.7.3(Measurement requirements for AC output ports for stand-alone inverters) |
- |
5000 |
|
- |
| 4.7.4(Stand-alone Inverter AC output voltage and frequency) |
- |
5000 |
|
- |
| 4.7.4.2(Steady state output voltage at nominal DC input) |
- |
5000 |
|
- |
| 4.7.4.3(Steady state output voltage across the DC input range) |
- |
5000 |
|
- |
| 4.7.4.4(Load step response of the output voltage at nominal DC input) |
- |
5000 |
|
- |
| 4.7.4.5(Steady state output frequency) |
- |
5000 |
|
- |
| 4.7.5(Stand-alone inverter output voltage waveform) |
- |
5000 |
|
- |
| 4.7.5.2(Sinusoidal output voltage waveform requirements) |
- |
5000 |
|
- |
| 4.7.5.3(Non-sinusoidal output waveform requirements) |
- |
5000 |
|
- |
| 4.7.5.5(Output voltage waveform requirements for inverters for dedicated loads) |
- |
5000 |
|
- |
| 4.8.2.1(Array insulation resistance detection for inverters for ungrounded arrays) |
- |
5000 |
|
- |
| 4.8.2.2(Array insulation resistance detection for inverters for functionally grounded arrays) |
- |
5000 |
|
- |
| 4.8.3.2(30 mA touch current type test for isolated inverters) |
- |
5000 |
|
- |
| 4,8.3.3(Fire hazard residual current type test for isolated inverters) |
- |
5000 |
|
- |
| 4.8.3.5(Protection by residual current monitoring) |
- |
5000 |
|
- |
| 7.3.10(Additional requirements for stand-alone inverters) |
- |
5000 |
|
- |
| 9.3.4(Inverter backfeed current onto the array) |
- |
5000 |
|
- |
| 13.9(Fault indication) |
- |
5000 |
|
- |
|
- |
- Included w.e.f. 23.02.2024
Exclusion: Cl.14 (Components), CL.6.4 (UV exposure), Cl.13.6.4 (UV Resistance), Cl.Annex J (Ultraviolet light conditioning test), Cl.9.1.4.3 (Hot flaming oil test) |
| 7715 |
Alpha Test House Private Limited, Delhi
| 8131026
| IS 16221 : Part 1 (2016) |
Safety of Power Converters for use in Photovoltaic Power Systems Part 1 General Requirements |
- |
524000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 13.6.2.1(Stress relief test) |
- |
5000 |
|
- |
| 9(Protection Against Fire Hazards) |
- |
10000 |
|
- |
| 8(Protection Against mechanical Hazards) |
- |
10000 |
|
- |
| 7(Protection against electric shock and energy hazards) |
- |
5000 |
|
- |
| 5(Marking and documentation) |
- |
5000 |
|
- |
| 4(General testing requirements) |
- |
1000 |
|
- |
| 6.4(UV exposure) |
- |
1000 |
|
- |
| 4.2(Thermal testing) |
- |
10000 |
|
- |
| 4.4(Testing in single fault condition) |
- |
10000 |
|
- |
| 4.5(Humidity preconditioning) |
- |
10000 |
|
- |
| 4.6(Backfeed voltage protection) |
- |
5000 |
|
- |
| 4.7(Electrical rating tests) |
- |
3000 |
|
- |
| 4.8(Additional tests for grid interactive inverters) |
- |
5000 |
|
- |
| Annex A(Measurement of clearances and creepage distances) |
- |
3000 |
|
- |
| Annex B(Programmable equipment) |
- |
1000 |
|
- |
| Annex C(Symbols to be used in equipment markings) |
- |
1000 |
|
- |
| Annex D(Test probes for determining access) |
- |
1000 |
|
- |
| Annex E(RCDs) |
- |
1000 |
|
- |
| Annex F(Altitude correction for clearances) |
- |
1000 |
|
- |
| Annex G(Clearance and creepage distance determination for frequencies greater than 30 kHz) |
- |
1000 |
|
- |
| Annex H("Measuring instrument for touch current measurements
") |
- |
1000 |
|
- |
| Annex I("Examples of protection, insulation, and overvoltage category requirements for PCE
") |
- |
1000 |
|
- |
| 4.3, 4.3.2, 4.3.2.2, 4.3.2.3(Thermal Tests (Maximum temperatures, Touch temperature, temperature limits for mount surfaces)) |
- |
10000 |
|
- |
| 4.4.3.1(Protection against shock hazard) |
- |
5000 |
|
- |
| 4.4.3.2(Protection against spread of fire) |
- |
5000 |
|
- |
| 4.4.3.4(Protection Against parts expulsion hazards) |
- |
5000 |
|
- |
| 4.4.4.5(Output short circuit) |
- |
5000 |
|
- |
| 4.4.4.6(Backfeed current test for equipment with more than one source of supply) |
- |
5000 |
|
- |
| 4.4.4.7(Output overload) |
- |
5000 |
|
- |
| 4.4.4.8(Cooling system failure) |
- |
5000 |
|
- |
| 4.4.4.9(Heating devices) |
- |
5000 |
|
- |
| 4.4.4.10(Safety interlock systems) |
- |
5000 |
|
- |
| 4.4.4.11(Reverse d.c. connections) |
- |
5000 |
|
- |
| 4.4.4.12(Voltage selector mismatch) |
- |
5000 |
|
- |
| 4.4.4.13(Mis-wiring with incorrect phase sequence or polarity) |
- |
5000 |
|
- |
| 4.4.4.14(Printed wiring board short-circuit test) |
- |
5000 |
|
- |
| 4.6.1(Backfeed tests under normal conditions) |
- |
5000 |
|
- |
| 4.6.2(Backfeed tests under single-fault conditions) |
- |
5000 |
|
- |
| 5.1.2(Durability of markings) |
- |
5000 |
|
- |
| 5.2.1(Visibility and legibility requirements for warning markings) |
- |
1000 |
|
- |
| 7.3.2.3(Short-term limits of accessible voltages under fault conditions) |
- |
5000 |
|
- |
| 7.3.2.6(Working voltage and DVC) |
- |
5000 |
|
- |
| 7.3.4,7.3.4.2(protection against direct contact) |
- |
5000 |
|
- |
| 7.3.4.3(Protection by means of insulation of live parts) |
- |
5000 |
|
- |
| 7.3.5,7.3.5.2(Protection in case of direct contact) |
- |
5000 |
|
- |
| 7.3.5.3.1(Limitation of current through protective impedance) |
- |
5000 |
|
- |
| 7.3.5.3.2(Limitation of discharging energy through protective impedance) |
- |
5000 |
|
- |
| 7.3.5.4(Protection by means of limited voltages) |
- |
5000 |
|
- |
| 7.3.6.1,7.3.6.2(Protection against indirect contact(Creapage & clearance)) |
- |
5000 |
|
- |
| 7.3.6.3(Protective class I - Protective bonding and earthing) |
- |
5000 |
|
- |
| 7.3.6.3.3(Rating of protective bonding) |
- |
5000 |
|
- |
| 7.3.7.4(Clearance distances) |
- |
5000 |
|
- |
| 7.3.7.5(Creepage distances) |
- |
5000 |
|
- |
| 7.3.8(Residual current detection (RCD) or Monitoring (RCM) device compatibilty (DC components on AC side)) |
- |
5000 |
|
- |
| 7.3.9(Protection against shock hazard due to stored energy) |
- |
5000 |
|
- |
| 7.4(Protection against energy hazards) |
- |
5000 |
|
- |
| 7.5.1(Impulse voltage test (type test)) |
- |
5000 |
|
- |
| 7.5.2(Voltage test (dielectric strength test)) |
- |
5000 |
|
- |
| 7.5.4(Touch current measurement) |
- |
5000 |
|
- |
| 8.2(Moving parts) |
- |
5000 |
|
- |
| 8.3(Stability) |
- |
5000 |
|
- |
| 8.4(Provisions for lifting and carrying) |
- |
5000 |
|
- |
| 8.5(Wall mounting) |
- |
5000 |
|
- |
| 8.6(Expelled parts) |
- |
5000 |
|
- |
| 9.1.1(Reducing the risk of ignition and spread of flame) |
- |
5000 |
|
- |
| 9.1.2(Conditions for a fire enclosure) |
- |
5000 |
|
- |
| 9.1.3(Material requirements for protection against fire hazard) |
- |
5000 |
|
- |
| 9.1.4(Openings in fire enclosures) |
- |
5000 |
|
- |
| 9.1.4.6(Additional requirements for openings in transportable equipment) |
- |
5000 |
|
- |
| 9.2.2(Limited power source tests) |
- |
5000 |
|
- |
| 9.3(Short-circuit and overcurrent protection) |
- |
5000 |
|
- |
| 11.1(Liquid containment, pressure and leakage) |
- |
5000 |
|
- |
| 11.2(Fluid pressure and leakage) |
- |
5000 |
|
- |
| 13.1(Handles and manual controls) |
- |
5000 |
|
- |
| 13.2(Securing of parts) |
- |
5000 |
|
- |
| 13.3(Provisions for external connections) |
- |
5000 |
|
- |
| 13.4(Internal wiring and connections) |
- |
5000 |
|
- |
| 13.5(Openings in enclosures) |
- |
5000 |
|
- |
| 13.3.2.5(Cord anchorages and strain relief) |
- |
5000 |
|
- |
| 13.3.5(Wire bending space for wires 10mm2 and greater) |
- |
5000 |
|
- |
| 13.5(Openings in enclosures) |
- |
5000 |
|
- |
| 13.7(Mechanical resistance to deflection, impact, or drop) |
- |
5000 |
|
- |
| 13.8(Thickness requirements for metal enclosures) |
- |
5000 |
|
- |
| 14.2(Motor over-temperature protection) |
- |
5000 |
|
- |
| 14.3(Over-temperature protection devices) |
- |
5000 |
|
- |
| 14.6(Printed circuit boards) |
- |
5000 |
|
- |
| 14.7(Circuits or components used as transient overvoltage limiting devices) |
- |
5000 |
|
- |
| 9.1.4.3(Hot flaming oil test) |
- |
5000 |
|
- |
| 7.3.7.8.4.2(Use of coating materials (on PWBs)) |
- |
5000 |
|
- |
| 7.5.3(Partial discharge test (type test or sample test)) |
- |
20000 |
|
- |
| 10.2(Sonic pressure and sound level) |
- |
5000 |
|
- |
| 10(Protection against Sonic Pressure hazards) |
- |
5000 |
|
- |
| 6.3(Ingress protection) |
- |
10000 |
|
- |
| 15(Software and firmware performing safety functions) |
- |
5000 |
|
- |
| 12(Chemical hazards) |
- |
5000 |
|
- |
| 11(Protection against liquid hazards) |
- |
5000 |
|
- |
| 6(Environmental Requirements and conditions) |
- |
10000 |
|
- |
| 4.4.4.1(Component fault tests) |
- |
5000 |
|
- |
| 4.4.4.2(Equipment’s or parts for short-term or intermittent operation) |
- |
5000 |
|
- |
| 4.4.4.3(Motors(Lock rotor)) |
- |
5000 |
|
- |
| 4.4.4.4(Transformer short circuit tests) |
- |
5000 |
|
- |
| 13.1.1(Adjustable controls) |
- |
5000 |
|
- |
| 7.3.7.5(Creepage distances) |
- |
5000 |
|
- |
| 7.3.8(Residual current detection (RCD) or Monitoring (RCM) device compatibilty (DC components on AC side)) |
- |
5000 |
|
- |
| 7.3.9(Protection against shock hazard due to stored energy) |
- |
5000 |
|
- |
| 7.4(Protection against energy hazards) |
- |
5000 |
|
- |
| 7.5.1(Impulse voltage test (type test)) |
- |
5000 |
|
- |
| 7.5.2(Voltage test (dielectric strength test)) |
- |
5000 |
|
- |
| 7.5.2.3(Humidity preconditioning) |
- |
10000 |
|
- |
| 7.5.3(Partial discharge test (type test or sample test)) |
- |
20000 |
|
- |
| 7.5.4(Touch current measurement) |
- |
5000 |
|
- |
|
- |
- Included w.e.f. 23.02.2024
Exclusion: Cl.14 (Components), Cl.6.4 (UV exposure), Cl.13.6.4 (UV Resistance), Annex J (Ultraviolet light conditioning test), Cl.9.1.4.3 (Hot flaming oil test), Cl.14.2 (Motor over-temperature protection), Cl.14.3 (Over-temperature protection devices), Cl.14.6 (Printed circuit boards), Cl.14.7 (Circuits or components used as transient overvoltage limiting devices) |
| 7716 |
Alpha Test House Private Limited, Delhi
| 8131026
| IS 16169 (2019) |
Utility - Interconnected photovoltaic inverters - Test procedure of islanding prevention measures (First Revision) |
- |
157000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 6(Test for single or multi-phase inverter) |
- |
145000 |
|
- |
| Annex A(Islanding as it applies to PV systems) |
- |
1000 |
|
- |
| Annex B(Test for independent islanding device) |
- |
1000 |
|
- |
| 6 to 6.2(Test for single or multi-phase inverter to Pass/fail criteria) |
- |
5000 |
|
- |
| 7(Documentation) |
- |
2000 |
|
- |
| 4(Testing circuit) |
- |
1000 |
|
- |
| 5(Testing equipment) |
- |
1000 |
|
- |
| Annex C(Gate blocking signal) |
- |
1000 |
|
- |
| 6 to 6.2(Test for single or multi-phase inverter to Pass/fail criteria) |
- |
- |
|
- |
| 7(Documentation) |
- |
- |
|
- |
| 4(Testing circuit) |
- |
- |
|
- |
| 5(Testing equipment) |
- |
- |
|
- |
| Annex C(Gate blocking signal) |
- |
- |
|
- |
|
- |
- Included w.e.f. 23.02.2024 |
| 7717 |
Alpha Test House Private Limited, Delhi
| 8131026
| IS 10322 : Part 5 : Sec 1 (2012) |
Luminaires: Part 5 particular requirements: Sec 1 fixed general purpose luminaires (First Revision) |
Fixed General Purpose Luminaires |
56000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4(General Test Requireements) |
- |
0 |
|
- |
| 5(Classification of Luminaires') |
- |
2000 |
|
- |
| 6.0(Marking) |
- |
2000 |
|
- |
| 7.0(Construction) |
- |
5000 |
|
- |
| 8.0(Creepage Distance and Clearances) |
- |
3000 |
|
- |
| 9.0(Provision for earthing) |
- |
3000 |
|
- |
| 10.0(Terminals) |
- |
5000 |
|
- |
| 11.0(External & Internal Wiring) |
- |
5000 |
|
- |
| 12.0(Protection against electric shock) |
- |
3000 |
|
- |
| 13.0(Endurance Tests and Thermal Tests) |
- |
12000 |
|
- |
| 14.0(Resistance to Dust & Moisture) |
- |
5000 |
|
- |
| 15.0(Insulation Resistance and Electric Strength) |
- |
5000 |
|
- |
| 16.0(Resistance to Heat , fire and tracking) |
- |
6000 |
|
- |
| 17.0(Photometric Test) |
- |
0 |
|
- |
|
- |
- Included w.e.f. 31.08.2023 |
| 7718 |
Alpha Test House Private Limited, Delhi
| 8131026
| IS 16242 : Part 1 (2014) |
Uninterruptible power systems (UPS): Part 1 general and safety requirements for UPS |
UPS and Inverters |
76000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4.6(Power interface) |
- |
5000 |
|
- |
| 4.7(Marking & instructions) |
- |
2000 |
|
- |
| 5.1(Protection against shock and energy hazards) |
- |
3000 |
|
- |
| 5.2(Requirement of auxiliary circuits) |
- |
2000 |
|
- |
| 5.3(Protective earthing and bonding) |
- |
3000 |
|
- |
| 5.4(AC and DC power isolation) |
- |
2000 |
|
- |
| 5.5(Over current and earth fault condition) |
- |
2000 |
|
- |
| 5.6(Safety interlocks) |
- |
1000 |
|
- |
| 5.7(CLEARANCES, CREEPAGE DISTANCES AND SOLID INSULATION) |
- |
2000 |
|
- |
| 6.1(Wiring, connections and supply) |
- |
2000 |
|
- |
| 6.2(Connection to power) |
- |
1000 |
|
- |
| 6.3(Wiring terminals for external power conductors) |
- |
1000 |
|
- |
| 7.1(Enclosure) |
- |
2000 |
|
- |
| 7.2(STABILITY) |
- |
3000 |
|
- |
| 7.3(MECHANICAL STRENGTH) |
- |
5000 |
|
- |
| 7.4(Construction details) |
- |
3000 |
|
- |
| 7.5(Resistance to fire) |
- |
5000 |
|
- |
| 7.6(Battery location) |
- |
1000 |
|
- |
| 4.5(Components) |
- |
1000 |
|
- |
| 7.7(Temperature rise) |
- |
6000 |
|
- |
| 8.1(General procision for earth leakage) |
- |
5000 |
|
- |
| 8.2(Electric Strength) |
- |
3000 |
|
- |
| 8.3(Abnormal operating and fault conditions) |
- |
5000 |
|
- |
| 9.0(Connection to telecommunication networks) |
- |
1000 |
|
- |
| 4.5/RD 1.5(Components) |
- |
1000 |
|
- |
| 2.10.5.11(SMPS/Main transformer) |
- |
1000 |
|
- |
| 2.10.6(PCB Material) |
- |
1000 |
|
- |
| 3.2.5(Non-rewirable plug with PVC sheathed cable) |
- |
1000 |
|
- |
| 3.2.4(Appliances inlets/connectors) |
- |
1000 |
|
- |
| 2.10.5.4(Semiconductor devices) |
- |
1000 |
|
- |
| 2.10.5.13(Winding wires) |
- |
1000 |
|
- |
| 4.3.8(Batteries) |
- |
1000 |
|
- |
| 2.10.5.6(Thin sheet material) |
- |
1000 |
|
- |
| 5.6.1/ RD 2.8.7(Switches & Relays) |
- |
1000 |
|
- |
| 6.1.1/ RD 3.1.4(Insulating Conductors) |
- |
1000 |
|
- |
| Annex I.5(Solid-state backfeed protection) |
- |
1000 |
|
- |
| I.5(transient overvoltages) |
- |
0 |
|
- |
| I.5(voltage variations) |
- |
0 |
|
- |
| I.5(electromagnetic susceptibility) |
- |
0 |
|
- |
| I.5(electrostatic discharge) |
- |
0 |
|
- |
| Annex I.5(Solid-state backfeed protection) |
- |
0 |
|
- |
|
- |
- Included w.e.f. 02.12.2023. Exclusion: Annex I.5 (transient overvoltages, voltage variations, electromagnetic susceptibility, electrostatic discharge, Solid-state backfeed protection), Cl. 2.10.6 (PCB Material), Cl. 3.2.5 (Non-rewirable plug with PVC sheathed cable), Cl. 2.10.5.4 (Semiconductor devices), Cl. 5.6.1/ RD 2.8.7 (Switches & Relays), Annex M (Ventilation of battery compartments), Cl. 2.10.8 of RD (Tests on coated printed boards and coated components), Cl. 2.10.9 of RD (Thermal cycling), Cl. 2.10.10 of RD (Test for Pollution Degree 1 environment and for insulating compound), Cl. 2.10.11 of RD (Tests for semiconductor devices and for cemented joints) |
| 7719 |
Alpha Test House Private Limited, Delhi
| 8131026
| IS 10322 : Part 5 : Sec 9 (2017) |
Luminaires: Part 5 particular requirements: Sec 9 rope lights |
Rope Light |
45000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 21.4(General Test Requireements) |
- |
1000 |
|
- |
| 21.5(Classification of Luminaires') |
- |
2000 |
|
- |
| 21.6(Marking) |
- |
2000 |
|
- |
| 21.7(Construction) |
- |
5000 |
|
- |
| 21.8(Creepage Distance and Clearances) |
- |
3000 |
|
- |
| 21.9(Provision for earthing) |
- |
0 |
|
- |
| 21.10(Terminals) |
- |
5000 |
|
- |
| 21.11(External & Internal Wiring) |
- |
2000 |
|
- |
| 21.12(Protection against electric shock) |
- |
3000 |
|
- |
| 21.13(Endurance Tests and Thermal Tests) |
- |
12000 |
|
- |
| 21.14(Resistance to Dust & Moisture) |
- |
2000 |
|
- |
| 21.15(Insulation Resistance and Electric Strength) |
- |
2000 |
|
- |
| 21.16(Resistance to Heat , fire and tracking) |
- |
6000 |
|
- |
| 21.7.1(General) |
- |
0 |
|
- |
| 21.7.3(Terminals and supply connections) |
- |
0 |
|
- |
| 21.7.4(Control units) |
- |
0 |
|
- |
| 21.7.5(Mechanical strength) |
- |
0 |
|
- |
|
- |
- Included w.e.f. 17.11.2023 |
| 7720 |
Alpha Test House Private Limited, Delhi
| 8131026
| IS 302 : Part 2 : Sec 23 (2009) |
Safety of household and similar electrical appliances: Part 2 particular requirements: Sec 23 appliances for skin or hair care (First Revision) |
- |
24500.00 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 32(Radiation ,Toxicity and similar hazards) |
- |
1000 |
|
Testing charges |
| 31(Resistance to Rusting) |
- |
1000 |
|
Testing charges |
| 30(Resistance to Heat & Fire) |
- |
1800 |
|
Testing charges |
| 29(Clearances, Creepage Distances & Solid Insulation) |
- |
1000 |
|
Testing charges |
| 28(Screws & Connection) |
- |
1000 |
|
Testing charges |
| 27(Provision For Earthing) |
- |
1000 |
|
Testing charges |
| 26(Terminals For External Conductors) |
- |
1000 |
|
Testing charges |
| 25(Supply Connection & External Flexible Cables and Cords) |
- |
1000 |
|
Testing charges |
| 24(Component) |
- |
1000 |
|
Testing charges |
| 23(Internal wiring) |
- |
1000 |
|
Testing charges |
| 22(Construction) |
- |
1000 |
|
Testing charges |
| 21(Mechanical strength) |
- |
1000 |
|
Testing charges |
| 20(Stability & Mechanical Hazards) |
- |
1000 |
|
Testing charges |
| 19(Abnormal Operation) |
- |
1000 |
|
Testing charges |
| 18(Endurance) |
- |
0 |
|
Testing charges |
| 17(Overload Protection/ Overload Protection of Transformers & Associated Circuits) |
- |
1000 |
|
Testing charges |
| 16(Leakage Current and Electric Strength) |
- |
1000 |
|
Testing charges |
| 15(Moisture Resistance) |
- |
1000 |
|
Testing charges |
| 14(Transient Over Voltage) |
- |
1000 |
|
Testing charges |
| 13(Leakage Current and Electric Strength at Operating Temperature) |
- |
500 |
|
Testing charges |
| 11(Temperature Rise/Heating) |
- |
1800 |
|
Testing charges |
| 10(Power Input
& Current) |
- |
1000 |
|
Testing charges |
| 9(Starting Of Motor Operated Appliances) |
- |
0 |
|
Testing charges |
| 8(Protection against Electric Shock/ Protection against Access to Live Parts) |
- |
1000 |
|
Testing charges |
| 7(Marking/ Marking & Instructions) |
- |
1000 |
|
Testing charges |
| 6(Classification) |
- |
100 |
|
Testing charges |
| 22.32(CONSTRUCTION) |
- |
0 |
|
Testing charges |
|
- |
- Included w.e.f. 17.11.2023. Exclusion: Cl 19.11.4.1 to 19.11.4.7 (EMI/EMC Tests), Cl 24.1. 1,24.1.2 & 24.1.5 (Components) |
| 7721 |
Alpha Test House Private Limited, Delhi
| 8131026
| IS 302 : Part 2 : Sec 13 (1994) |
Safety of household and similar electrical appliances: Part 2 particular requirements: Sec 13 frying pans, deep fat fryers and similar appliances |
- |
24000.00 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 32(Radiation ,Toxicity and similar hazards) |
- |
1000 |
|
Testing charges |
| 31(Resistance to Rusting) |
- |
1000 |
|
Testing charges |
| 30(Resistance to Heat, Fire and Tracking) |
- |
1800 |
|
Testing charges |
| 29(Clearances, Creepage Distances & Solid Insulation) |
- |
1000 |
|
Testing charges |
| 28(Screws & Connections) |
- |
1000 |
|
Testing charges |
| 27(Provision For Earthing) |
- |
1000 |
|
Testing charges |
| 26(Terminals For External Conductors) |
- |
1000 |
|
Testing charges |
| 25(Supply Connection & External Flexible Cables and Cords) |
- |
1000 |
|
Testing charges |
| 24(Components) |
- |
1000 |
|
Testing charges |
| 23(Internal wiring) |
- |
1000 |
|
Testing charges |
| 22(Construction) |
- |
1000 |
|
Testing charges |
| 21(Mechanical strength) |
- |
1000 |
|
Testing charges |
| 20(Stability & Mechanical Hazards) |
- |
1000 |
|
Testing charges |
| 19(Abnormal Operation) |
- |
1000 |
|
Testing charges |
| 18(Endurance) |
- |
0 |
|
Testing charges |
| 17(Overload Protection/ Overload Protection of Transformers & Associated Circuits) |
- |
1000 |
|
Testing charges |
| 16(Leakage Current and Electric Strength) |
- |
0 |
|
Testing charges |
| 15(Moisture Resistance) |
- |
1800 |
|
Testing charges |
| 14(Transient Over Voltage) |
- |
1000 |
|
Testing charges |
| 13(Leakage Current and Electric Strength at Operating Temperature) |
- |
500 |
|
Testing charges |
| 11(Temperature Rise/Heating) |
- |
1800 |
|
Testing charges |
| 10(Power Input) |
- |
1000 |
|
Testing charges |
| 9(Starting Of Motor Operated Appliances) |
- |
0 |
|
Testing charges |
| 8(Protection against Electric Shock/ Protection against Access to Live Parts) |
- |
1000 |
|
Testing charges |
| 7(Marking/ Marking & Instructions) |
- |
1000 |
|
Testing charges |
| 6(Classification) |
- |
100 |
|
Testing charges |
| 5(Rating) |
- |
0 |
|
Testing charges |
|
- |
- Cl. 19.11.4.1 to 19.11.4.7
24 (Components) |
| 7722 |
Alpha Test House Private Limited, Delhi
| 8131026
| IS 302 : Part 2 : Sec 9 (2009) |
Safety of household and similar electrical appliances: Part 2 particular requirements: Sec 9 toasters, grills, roasters and similar appliances (First Revision) |
- |
9800.00 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl.32(Verification) |
- |
0 |
|
Testing charges |
| Cl.31(Verification) |
- |
0 |
|
Testing charges |
| Cl.30(Verification) |
- |
0 |
|
Testing charges |
| CL.29(Verification) |
- |
0 |
|
Testing charges |
| Cl.28(Verification) |
- |
0 |
|
Testing charges |
| Cl.27(Verification) |
- |
0 |
|
Testing charges |
| Cl.26(Verification) |
- |
0 |
|
Testing charges |
| Cl.25(Verification) |
- |
0 |
|
Testing charges |
| Cl.24(Verification) |
- |
0 |
|
Testing charges |
| Cl.23(Verification) |
- |
0 |
|
Testing charges |
| Cl.22(Verification) |
- |
0 |
|
Testing charges |
| Cl.21(Verification) |
- |
0 |
|
Testing charges |
| Cl.20(Verification) |
- |
0 |
|
Testing charges |
| Cl.19(Verification) |
- |
0 |
|
Testing charges |
| Cl. 16(Verification) |
- |
0 |
|
Testing charges |
| Cl.15.1(Moisture Resistance) |
- |
0 |
|
Testing charges |
| Cl.14(Verification) |
- |
0 |
|
Testing charges |
| Cl.13(Verification) |
- |
0 |
|
Testing charges |
| Cl.11(Verification) |
- |
0 |
|
Testing charges |
| Cl.10(Verification) |
- |
0 |
|
Testing charges |
| Cl.8(Verification) |
- |
0 |
|
Testing charges |
| Cl. 7(Verification) |
- |
0 |
|
Testing charges |
| Cl. 6(Classification- IS 302-1) |
- |
0 |
|
Testing charges |
| Cl. 32
IS 302-2-9(Radiation, Toxicity and similar hazards) |
- |
0 |
|
Testing charges |
| Cl. 31
IS 302-2-9(Resistance To Rusting ) |
- |
0 |
|
Testing charges |
| Cl. 30
IS 302-2-9(Resistance To Heat, Fire And Tracking) |
- |
0 |
|
Testing charges |
| Cl. 29
IS 302-2-9(Creepage Distances, Clearances And Distances Through Insulation) |
- |
0 |
|
Testing charges |
| Cl. 28
IS 302-2-9(Screws and Connections) |
- |
0 |
|
Testing charges |
| Cl. 27
IS 302-2-9(Provision For Earthing ) |
- |
0 |
|
Testing charges |
| Cl. 26
IS 302-2-9(Terminal For External Conductors ) |
- |
0 |
|
Testing charges |
| Cl. 25
IS 302-2-9(Supply Connections and External Flexible Cables and Cords ) |
- |
0 |
|
Testing charges |
| Cl. 24
IS 302-2-9(Components) |
- |
0 |
|
Testing charges |
| Cl. 23
IS 302-2-9(Internal Wiring) |
- |
0 |
|
Testing charges |
| Cl. 22
IS 302-2-9(Construction ) |
- |
0 |
|
Testing charges |
| Cl. 21
IS 302-2-9(Mechanical Strength) |
- |
0 |
|
Testing charges |
| Cl. 20
IS 302-2-9(Stability and mechanical Hazards) |
- |
0 |
|
Testing charges |
| Cl. 19
IS 302-2-9(Abnormal Operation ) |
- |
0 |
|
Testing charges |
| Cl. 18
IS 302-2-9(Endurance) |
- |
0 |
|
Testing charges |
| Cl. 17
IS 302-2-9(Overload protection of transformers and associated circuits.) |
- |
0 |
|
Testing charges |
| Cl. 16
IS 302-2-9(Leakage Current and Electric strength ) |
- |
0 |
|
Testing charges |
| Cl. 15
IS 302-2-9(Moisture Resistance) |
- |
0 |
|
Testing charges |
| Cl. 14
IS 302-2-9(Transient overvoltage) |
- |
0 |
|
Testing charges |
| Cl. 13.3 IS 302-2-9(Leakage Current & Electric Strength at Operating Temperature) |
- |
0 |
|
Testing charges |
| Cl. 11
IS 302-2-9(Heating) |
- |
0 |
|
Testing charges |
| Cl. 10
IS 302-2-9(Power Input and Current ) |
- |
0 |
|
Testing charges |
| Cl. 9
IS 302-2-9(Starting of motor operated appliances) |
- |
0 |
|
Testing charges |
| Cl. 8
IS 302-2-9(Protection against access to live parts) |
- |
0 |
|
Testing charges |
| Cl. 7
IS 302-2-9(Marking and Instruction) |
- |
0 |
|
Testing charges |
| Cl. 6 IS 302-2-9(Classification- IS 302-1) |
- |
0 |
|
Testing charges |
| 32(Radiation, toxicity and similar hazards) |
- |
0 |
|
Testing charges |
| 31(Resistance to rusting) |
- |
0 |
|
Testing charges |
| 31(Resistance to rusting) |
- |
0 |
|
Testing charges |
| 30.2.4(Resistance to heat and fire) |
- |
0 |
|
Testing charges |
| 30.2(Resistance to heat and fire) |
- |
0 |
|
Testing charges |
| 30.1(Resistance to heat and fire) |
- |
0 |
|
Testing charges |
| 29.3(Clearances, creepage distances and solid insulation) |
- |
0 |
|
Testing charges |
| 29.2(Clearances, creepage distances and solid insulation) |
- |
0 |
|
Testing charges |
| 29.2(Clearances, creepage distances and solid insulation) |
- |
0 |
|
Testing charges |
| 29.1, Table No.- 16, Table No.- 17 & Table No.18(Clearances, creepage distances and solid insulation) |
- |
0 |
|
Testing charges |
| 29.1, Table No.- 16, Table No.- 17 & Table No.18(Clearances, creepage distances and solid insulation) |
- |
0 |
|
Testing charges |
| 28.2 to 28.4(Screws and connections) |
- |
0 |
|
Testing charges |
| 28.1, Table No.-14(Screws and connections) |
- |
0 |
|
Testing charges |
| 27.6(Provision for earthing) |
- |
0 |
|
Testing charges |
| 27.5(Provision for earthing) |
- |
0 |
|
Testing charges |
| 27.1 to 27.4(Provision for earthing) |
- |
0 |
|
Testing charges |
| 26.10 & 26.11(Terminals for external conductors) |
- |
0 |
|
Testing charges |
| 26.9(Terminals for external conductors) |
- |
0 |
|
Testing charges |
| 26.1 to 26.8(Terminals for external conductors) |
- |
0 |
|
Testing charges |
| 25.16 to 25.25(Supply connection and external flexible cords) |
- |
0 |
|
Testing charges |
| 25.15(Supply connection and external flexible cords) |
- |
0 |
|
Testing charges |
| 25.14(Supply connection and external flexible cords) |
- |
0 |
|
Testing charges |
| 25.14(Supply connection and external flexible cords) |
- |
0 |
|
Testing charges |
| 25.9 to 25.13(Supply connection and external flexible cords) |
- |
0 |
|
Testing charges |
| 25.8, Table No.-11(Supply connection and external flexible cords) |
- |
0 |
|
Testing charges |
| 25.5 to 25.7(Supply connection and external flexible cords) |
- |
0 |
|
Testing charges |
| 25.4(Supply connection and external flexible cords) |
- |
0 |
|
Testing charges |
| 25.3(Supply connection and external flexible cords) |
- |
0 |
|
Testing charges |
| 25.2(Supply connection and external flexible cords) |
- |
0 |
|
Testing charges |
| 25.1(Supply connection and external flexible cords) |
- |
0 |
|
Testing charges |
| 24.101(Components) |
- |
0 |
|
Testing charges |
| 24.2 to 24.6(Components) |
- |
0 |
|
Testing charges |
| 24.1(Components) |
- |
0 |
|
Testing charges |
| 23.6 to 23.10(Internal wiring) |
- |
0 |
|
Testing charges |
| 23.5(Internal wiring) |
- |
0 |
|
Testing charges |
| 23.4(Internal wiring) |
- |
0 |
|
Testing charges |
| 23.3(Internal wiring) |
- |
0 |
|
Testing charges |
| 23.1 & 23.2(Internal wiring) |
- |
0 |
|
Testing charges |
| 22.111(Constructions) |
- |
0 |
|
Testing charges |
| 22.111(Constructions) |
- |
0 |
|
Testing charges |
| 22.11o(Constructions) |
- |
0 |
|
Testing charges |
| 22.109(Constructions) |
- |
0 |
|
Testing charges |
| 22.108(Constructions) |
- |
0 |
|
Testing charges |
| 22.101 to 22.107(Constructions) |
- |
0 |
|
Testing charges |
| 31(Resistance to rusting) |
- |
0 |
|
Testing charges |
| 22.12(Constructions) |
- |
0 |
|
Testing charges |
| 22.11(Constructions) |
- |
0 |
|
Testing charges |
| 22.11(Constructions) |
- |
0 |
|
Testing charges |
| 22.7 to 22.10(Constructions) |
- |
0 |
|
Testing charges |
| 22.13 to 22.48(Constructions) |
- |
0 |
|
Testing charges |
| 22.6(Constructions) |
- |
0 |
|
Testing charges |
| 22.5(Constructions) |
- |
0 |
|
Testing charges |
| 22.4(Constructions) |
- |
0 |
|
Testing charges |
| 22.3(Constructions) |
- |
0 |
|
Testing charges |
| 22.2(Constructions) |
- |
0 |
|
Testing charges |
| 22.1(Constructions) |
- |
0 |
|
Testing charges |
| 21.101(MECHANICAL STRENGTH) |
- |
0 |
|
Testing charges |
| 21.101(MECHANICAL STRENGTH) |
- |
0 |
|
Testing charges |
| 21.2(MECHANICAL STRENGTH) |
- |
0 |
|
Testing charges |
| 20.2(Stability and mechanical hazards) |
- |
0 |
|
Testing charges |
| 20.1(Stability and mechanical hazards) |
- |
0 |
|
Testing charges |
| 19.104(ABNORMAL OPERATION) |
- |
0 |
|
Testing charges |
| 19.103(ABNORMAL OPERATION) |
- |
0 |
|
Testing charges |
| 19.102(ABNORMAL OPERATION) |
- |
0 |
|
Testing charges |
| 19.101(ABNORMAL OPERATION) |
- |
0 |
|
Testing charges |
| 19.1 to 19.13, Table No. - 9(ABNORMAL OPERATION) |
- |
0 |
|
Testing charges |
| 17(Overload protection of transformers and associated circuits) |
- |
0 |
|
Testing charges |
| 16.3(Insulation resistance test) |
- |
0 |
|
Testing charges |
| 16.3(Electric strength test) |
- |
0 |
|
Testing charges |
| 16.1 & 16.2(Leakage current test) |
- |
0 |
|
Testing charges |
| 15.3(Moisture resistance) |
- |
0 |
|
Testing charges |
| 15.2(Moisture resistance) |
- |
0 |
|
Testing charges |
| 15.1(Moisture resistance) |
- |
0 |
|
Testing charges |
| 14, Table No.- 6 & Table No.-16(Transient over voltages) |
- |
0 |
|
Testing charges |
| 13.3 and Table No.- 4(Electric strength test) |
- |
0 |
|
Testing charges |
| 13.1, 13.2(Leakage current test) |
- |
0 |
|
Testing charges |
| 11.101(Heating) |
- |
0 |
|
Testing charges |
| 10.1 & 10.2 -Table No. 1, Table No. 2(Power Input and Current) |
- |
0 |
|
Testing charges |
| 8.1.5(Protection against access to live parts) |
- |
0 |
|
Testing charges |
| 8.1.4(Protection against access to live parts) |
- |
0 |
|
Testing charges |
| 8.1.3(Protection against access to live parts) |
- |
0 |
|
Testing charges |
| 8.1.2(Protection against access to live parts) |
- |
0 |
|
testing charges |
| 8.1, 8.1.1 & 8.2(Protection against access to live parts) |
- |
0 |
|
testing charges |
| 7.14(Legibility & Durability of Markings test) |
- |
0 |
|
testing charges |
| 32(Radiation, toxicity and similar hazards) |
- |
0 |
|
testing charges |
| 30.2.4(Resistance to heat and fire) |
- |
0 |
|
Testing charges |
| 30.1(Resistance to heat and fire) |
- |
0 |
|
Testing charges |
| 29.3(Clearances, creepage distances and solid insulation) |
- |
0 |
|
Testing charges |
| 29.2(Clearances, creepage distances and solid insulation) |
- |
0 |
|
Testing charges |
| 29.1, Table No.- 16, Table No.- 17 & Table No.18(Clearances, creepage distances and solid insulation) |
- |
0 |
|
Testing charges |
| 28.2 to 28.4(Screws and connections) |
- |
0 |
|
Testing charges |
| 28.1, Table No.-14(Screws and connections) |
- |
0 |
|
Testing charges |
| 27.6(Provision for earthing) |
- |
0 |
|
Testing charges |
| 27.5(Provision for earthing) |
- |
0 |
|
Testing charges |
| 27.1 to 27.4(Provision for earthing) |
- |
0 |
|
Testing charges |
| 26.9(Terminals for external conductors) |
- |
0 |
|
Testing charges |
| 26.1 to 26.8(Terminals for external conductors) |
- |
0 |
|
Testing charges |
| 25.16 to 25.25(Supply connection and external flexible cords) |
- |
0 |
|
Testing charges |
| 25.15(Supply connection and external flexible cords) |
- |
0 |
|
Testing charges |
| 25.14(Supply connection and external flexible cords) |
- |
0 |
|
Testing charges |
| 25.9 to 25.13(Supply connection and external flexible cords) |
- |
0 |
|
Testing charges |
| 25.8, Table No.-11(Supply connection and external flexible cords) |
- |
0 |
|
Testing charges |
| 25.5 to 25.7(Supply connection and external flexible cords) |
- |
0 |
|
Testing charges |
| 25.4(Supply connection and external flexible cords) |
- |
0 |
|
Testing charges |
| 25.3(Supply connection and external flexible cords) |
- |
0 |
|
Testing charges |
| 25.2(Supply connection and external flexible cords) |
- |
0 |
|
Testing charges |
| 25.1(Supply connection and external flexible cords) |
- |
0 |
|
Testing charges |
| 24.101(Components) |
- |
0 |
|
Testing charges |
| 24.2 to 24.6(Components) |
- |
0 |
|
Testing charges |
| 24.1(Components) |
- |
0 |
|
Testing charges |
| 23.6 to 23.10(Internal wiring) |
- |
0 |
|
Testing charges |
| 23.5(Internal wiring) |
- |
0 |
|
Testing charges |
| 23.4(Internal wiring) |
- |
0 |
|
Testing charges |
| 23.3(Internal wiring) |
- |
0 |
|
Testing charges |
| 23.1 & 23.2(Internal wiring) |
- |
0 |
|
Testing charges |
| 22.111(Constructions) |
- |
0 |
|
Testing charges |
| 22.11o(Constructions) |
- |
0 |
|
Testing charges |
| 22.109(Constructions) |
- |
0 |
|
Testing charges |
| 22.108(Constructions) |
- |
0 |
|
Testing charges |
| 22.101 to 22.107(Constructions) |
- |
0 |
|
Testing charges |
| 22.13 to 22.48(Constructions) |
- |
0 |
|
Testing charges |
| 22.11(Constructions) |
- |
0 |
|
Testing charges |
| 22.7 to 22.10(Constructions) |
- |
0 |
|
Testing charges |
| 22.6(Constructions) |
- |
0 |
|
Testing charges |
| 22.5(Constructions) |
- |
0 |
|
Testing charges |
| 22.4(Constructions) |
- |
0 |
|
Testing charges |
| 22.3(Constructions) |
- |
0 |
|
Testing charges |
| 22.2(Constructions) |
- |
0 |
|
Testing charges |
| 22.1(Constructions) |
- |
0 |
|
Testing charges |
| 21.101(MECHANICAL STRENGTH) |
- |
0 |
|
Testing charges |
| 21.2(MECHANICAL STRENGTH) |
- |
0 |
|
Testing charges |
| 21.1(MECHANICAL STRENGTH) |
- |
0 |
|
Testing charges |
| 20.2(Stability and mechanical hazards) |
- |
0 |
|
Testing charges |
| 19.104(ABNORMAL OPERATION) |
- |
0 |
|
Testing charges |
| 19.103(ABNORMAL OPERATION) |
- |
0 |
|
Testing charges |
| 19.102(ABNORMAL OPERATION) |
- |
0 |
|
Testing charges |
| 19.101(ABNORMAL OPERATION) |
- |
0 |
|
Testing charges |
| 19.1 to 19.13, Table No. - 9(ABNORMAL OPERATION) |
- |
0 |
|
Testing charges |
| 17(Overload protection of transformers and associated circuits) |
- |
0 |
|
Testing charges |
| 16.1 & 16.2(Leakage current test) |
- |
0 |
|
Testing charges |
| 15.3(Moisture resistance) |
- |
0 |
|
Testing charges |
| 15.2(Moisture resistance) |
- |
0 |
|
Testing charges |
| 15.1(Moisture resistance) |
- |
0 |
|
Testing charges |
| 13.1, 13.2(Leakage current test) |
- |
0 |
|
Testing charges |
| 11.101(Heating) |
- |
0 |
|
Testing charges |
| 10.1 & 10.2 -Table No. 1, Table No. 2(Power Input and Current) |
- |
0 |
|
Testing charges |
| 8.1.5(Protection against access to live parts) |
- |
0 |
|
Testing charges |
| 8.1.4(Protection against access to live parts) |
- |
0 |
|
Testing charges |
| 8.1.3(Protection against access to live parts) |
- |
0 |
|
Testing charges |
| 8.1.2(Protection against access to live parts) |
- |
0 |
|
Testing charges |
| 8.1, 8.1.1 & 8.2(Protection against access to live parts) |
- |
0 |
|
Testing charges |
| 7.14(Legibility & Durability of Markings test) |
- |
0 |
|
Testing charges |
| 7.1 to 7.13, 7.15, 7.16(Marking) |
- |
0 |
|
Testing charges |
| 32(Radiation ,Toxicity and similar hazards) |
- |
200 |
|
Testing charges |
| 31(Resistance to Rusting) |
- |
200 |
|
Testing charges |
| 30(Resistance to Heat & Fire) |
- |
600 |
|
Testing charges |
| 29(Clearances, Creepage Distances & Solid Insulation) |
- |
500 |
|
Testing charges |
| 28(Screws & Connections) |
- |
500 |
|
Testing charges |
| 27(Provision For Earthing) |
- |
500 |
|
Testing charges |
| 26(Terminals For External Conductors) |
- |
500 |
|
Testing charges |
| 25(Supply Connection & External Flexible Cords) |
- |
0 |
|
Testing charges |
| 24(Components) |
- |
400 |
|
Testing charges |
| 23(Internal wiring) |
- |
500 |
|
Testing charges |
| 22(Construction) |
- |
800 |
|
Testing charges |
| 21(Mechanical strength) |
- |
400 |
|
Testing charges |
| 20(Stability & Mechanical Hazards) |
- |
400 |
|
Testing charges |
| 19(Abnormal Operation) |
- |
400 |
|
Testing charges |
| 17(Overload Protection/ Overload Protection of Transformers & Associated Circuits) |
- |
400 |
|
Testing charges |
| 16(Leakage Current and Electric Strength) |
- |
300 |
|
Testing charges |
| 15(Moisture Resistance) |
- |
600 |
|
Testing charges |
| 14(Transient Over Voltage) |
- |
800 |
|
Testing charges |
| 13(Leakage Current and Electric Strength at Operating Temperature) |
- |
500 |
|
Testing charges |
| 11(Temperature Rise/ Heating) |
- |
300 |
|
Testing charges |
| 10(Power Input
& Current) |
- |
500 |
|
Testing charges |
| 9(Starting Of Motor Operated Appliances) |
- |
0 |
|
Testing charges |
|
- |
- Included w.e.f. 17.11.2023. Exclusion: Cl.19.11.4.1 to 19.11.4.7 (EMI/EMC), Cl.24.1.1, 24.1.2, 24.1.5 (Components) |
| 7723 |
Alpha Test House Private Limited, Delhi
| 8131026
| IS 302 : Part 2 : Sec 14 (2009) |
Safety of household and similar electrical appliances: Part 2 particular requirements: Sec 14 electric kitchen machines (First Revision) |
- |
12000.00 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 14(Transient Over Voltages, IS 302-1) |
- |
0 |
|
- |
| 15.1(Moisture Resistance, IS 302-1) |
- |
0 |
|
- |
| 15.2(Moisture Resistance, IS 302-1) |
- |
0 |
|
- |
| 16(Electrical Insulation and Leakage Current at Operating Temperature: Leakage current, IS 302-1) |
- |
0 |
|
- |
| 19.7(Abnormal Operation, IS 302-1) |
- |
0 |
|
- |
| 19.101(Abnormal Operation) |
- |
0 |
|
- |
| 27(Provision for Earthing) |
- |
0 |
|
- |
| 15(Moisture Resistance, IS 302-1) |
- |
0 |
|
- |
| 6(Classification- IS 302-1 ) |
- |
- |
|
- |
| 6(Classification- IS 302-1) |
- |
- |
|
- |
| 7.1(Marking- IS 302-1) |
- |
- |
|
- |
| 7.1(Marking- IS 302-1) |
- |
- |
|
- |
| 7.1(Marking- IS 302-1) |
- |
- |
|
- |
| 7.1(Marking- IS 302-1) |
- |
- |
|
- |
| 7.1(Marking- IS 302-1) |
- |
- |
|
- |
| 7.1(Marking- IS 302-1) |
- |
- |
|
- |
| 7.1(Marking- IS 302-1) |
- |
- |
|
- |
| 7.1(Marking- IS 302-1) |
- |
- |
|
- |
| 7.3(Marking- IS 302-1) |
- |
- |
|
- |
| 7.4(Marking- IS 302-1) |
- |
- |
|
- |
| 7.6(Marking- IS 302-1) |
- |
- |
|
- |
| 7.7(Marking- IS 302-1) |
- |
- |
|
- |
| 7.8(Marking- IS 302-1) |
- |
- |
|
- |
| 7.11(Marking- IS 302-1) |
- |
- |
|
- |
| 7.12(Marking- IS 302-1) |
- |
- |
|
- |
| 7.13(Marking- IS 302-1) |
- |
- |
|
- |
| 7.14(Marking- IS 302-1) |
- |
- |
|
- |
| 7.15(Marking- IS 302-1) |
- |
- |
|
- |
| 7.101(Marking) |
- |
- |
|
- |
| 8( Protection Against Electric Shock, IS 302-1) |
- |
- |
|
- |
| 10(Power Input and Current, IS 302-1) |
- |
- |
|
- |
| 11(Heating, IS 302-1) |
- |
- |
|
- |
| 11(Heating, IS 302-1) |
- |
- |
|
- |
| 11(Heating, IS 302-1) |
- |
- |
|
- |
| 11(Heating, IS 302-1) |
- |
- |
|
- |
| 11(Heating, IS 302-1) |
- |
- |
|
- |
| 13(Electrical Insulation and Leakage Current at Operating Temperature: Leakage current, IS 302-1) |
- |
- |
|
- |
| 13(Electrical Insulation and Leakage Current at Operating Temperature: High Voltage, IS 302-1) |
- |
- |
|
- |
| 17(Overload protection of Transformers and Associated Circuits, IS 302-1) |
- |
- |
|
- |
| 19.8(Abnormal Operation, IS 302-1) |
- |
- |
|
- |
| 19.9(Abnormal Operation, IS 302-1) |
- |
- |
|
- |
| 19.1(Abnormal Operation, IS 302-1) |
- |
- |
|
- |
| 19.102(Abnormal Operation) |
- |
- |
|
- |
| 20.1(Stability & Mechanical Hazards, IS 302-1) |
- |
- |
|
- |
| 20.2(Stability & Mechanical Hazards, IS 302-1) |
- |
- |
|
- |
| 20.101(Stability & Mechanical Hazards) |
- |
- |
|
- |
| 20.102(Stability & Mechanical Hazards) |
- |
- |
|
- |
| 20.103(Stability & Mechanical Hazards) |
- |
- |
|
- |
| 20.104(Stability & Mechanical Hazards) |
- |
- |
|
- |
| 20.105(Stability & Mechanical Hazards) |
- |
- |
|
- |
| 20.106(Stability & Mechanical Hazards) |
- |
- |
|
- |
| 20.107(Stability & Mechanical Hazards) |
- |
- |
|
- |
| 20.108(Stability & Mechanical Hazards) |
- |
- |
|
- |
| 20.109(Stability & Mechanical Hazards) |
- |
- |
|
- |
| 20.110(Stability & Mechanical Hazards) |
- |
- |
|
- |
| 20.111(Stability & Mechanical Hazards) |
- |
- |
|
- |
| 20.112(Stability & Mechanical Hazards) |
- |
- |
|
- |
| 20.113(Stability & Mechanical Hazards) |
- |
- |
|
- |
| 20.114(Stability & Mechanical Hazards) |
- |
- |
|
- |
| 20.115(Stability & Mechanical Hazards) |
- |
- |
|
- |
| 20.116(Stability & Mechanical Hazards) |
- |
- |
|
- |
| 21.1(Mechanical Strength, IS 302-1) |
- |
- |
|
- |
| 21.2(Mechanical Strength, IS 302-1) |
- |
- |
|
- |
| 22(Construction, IS 302-1) |
- |
- |
|
- |
| 22.101(Construction) |
- |
- |
|
- |
| 22.102(Construction) |
- |
- |
|
- |
| 23.1(Internal Wiring, IS 302-1) |
- |
- |
|
- |
| 23.2(Internal Wiring, IS 302-1) |
- |
- |
|
- |
| 23.3(Internal Wiring, IS 302-1) |
- |
- |
|
- |
| 23.4(Internal Wiring, IS 302-1) |
- |
- |
|
- |
| 23.5(Internal Wiring, IS 302-1) |
- |
- |
|
- |
| 23.6(Internal Wiring, IS 302-1) |
- |
- |
|
- |
| 23.7(Internal Wiring, IS 302-1) |
- |
- |
|
- |
| 23.8(Internal Wiring, IS 302-1) |
- |
- |
|
- |
| 23.9(Internal Wiring, IS 302-1) |
- |
- |
|
- |
| 23.10(Internal Wiring, IS 302-1) |
- |
- |
|
- |
| 24.1(Components, IS 302-1) |
- |
- |
|
- |
| 24.2(Components, IS 302-1) |
- |
- |
|
- |
| 24.5(Components, IS 302-1) |
- |
- |
|
- |
| 24.6(Components, IS 302-1) |
- |
- |
|
- |
| 25.1(Supply Connection and External Flexible Cords, IS 302-1) |
- |
- |
|
- |
| 25.5(Supply Connection and External Flexible Cords, IS 302-1) |
- |
- |
|
- |
| 25.6(Supply Connection and External Flexible Cords, IS 302-1) |
- |
- |
|
- |
| 25.7(Supply Connection and External Flexible Cords, IS 302-1) |
- |
- |
|
- |
| 25.8(Supply Connection and External Flexible Cords, IS 302-1) |
- |
- |
|
- |
| 26.9(Supply Connection and External Flexible Cords, IS 302-1) |
- |
- |
|
- |
| 25.1(Supply Connection and External Flexible Cords, IS 302-1) |
- |
- |
|
- |
| 25.11(Supply Connection and External Flexible Cords, IS 302-1) |
- |
- |
|
- |
| 25.12(Supply Connection and External Flexible Cords, IS 302-1) |
- |
- |
|
- |
| 25.13(Supply Connection and External Flexible Cords, IS 302-1) |
- |
- |
|
- |
| 25.14(Supply Connection and External Flexible Cords, IS 302-1) |
- |
- |
|
- |
| 25.14(Supply Connection and External Flexible Cords, IS 302-1) |
- |
- |
|
- |
| 25.15(Supply Connection and External Flexible Cords, IS 302-1) |
- |
- |
|
- |
| 25.16(Supply Connection and External Flexible Cords, IS 302-1) |
- |
- |
|
- |
| 25.17(Supply Connection and External Flexible Cords, IS 302-1) |
- |
- |
|
- |
| 25.18(Supply Connection and External Flexible Cords, IS 302-1) |
- |
- |
|
- |
| 25.19(Supply Connection and External Flexible Cords, IS 302-1) |
- |
- |
|
- |
| 25.2(Supply Connection and External Flexible Cords, IS 302-1) |
- |
- |
|
- |
| 25.21(Supply Connection and External Flexible Cords, IS 302-1) |
- |
- |
|
- |
| 25.22(Supply Connection and External Flexible Cords, IS 302-1) |
- |
- |
|
- |
| 26(Terminals for External Conductors, IS 302-1) |
- |
- |
|
- |
| 27(Provision for Earthing, IS 302-1) |
- |
- |
|
- |
| 27.2(Provision for Earthing, IS 302-1) |
- |
- |
|
- |
| 27.3(Provision for Earthing, IS 302-1) |
- |
- |
|
- |
| 27.4(Provision for Earthing, IS 302-1) |
- |
- |
|
- |
| 27.5(Provision for Earthing, IS 302-1) |
- |
- |
|
- |
| 28(Screws & Connections, IS 302-1) |
- |
- |
|
- |
| 29.1(Clearances, Creepage distances and Solid Insulation, IS 302-1) |
- |
- |
|
- |
| 29.2(Clearances, Creepage distances and Solid Insulation, IS 302-1) |
- |
- |
|
- |
| 30.1(Resistance to Heat and Fire, IS 302-1) |
- |
- |
|
- |
| 30.2(Resistance to Heat and Fire, IS 302-1) |
- |
- |
|
- |
| 31(Resistance of Rusting, IS 302-1) |
- |
- |
|
- |
| 32(Radiation, Toxicity and similar Hazard IS 302-1) |
- |
- |
|
- |
|
- |
- Included w.e.f. 17.11.2023. Exclusion: Cl 19.11.4.1 to 19.11.4.7 (EMI/EMC Tests), Cl 24.1. 1,24.1.2 & 24.1.5 (Components) |
| 7724 |
Alpha Test House Private Limited, Delhi
| 8131026
| IS 7809 : Part 3 : Sec 1 (1986) |
Specification for pressure sensitive adhesive insulating tapes for electrical purposes: Part 3 requirements or individual materials: Sec 1 plasticized polyvinylchloride tapes with non - Thermosetting adhesive (First Revision) |
- |
19400.00 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 3.1(Marking, Cl.9 of IS 7809 (Part 1):1975) |
- |
10 |
|
- |
| 3.1(Marking, Cl.9 of IS 7809 (Part 1):1975) |
- |
10 |
|
- |
| 3.1(Marking, Cl.9 of IS 7809 (Part 1):1975) |
- |
10 |
|
- |
| 3.1(Marking, Cl.9 of IS 7809 (Part 1):1975) |
- |
10 |
|
- |
| 3.1(Marking, Cl.9 of IS 7809 (Part 1):1975) |
- |
10 |
|
- |
| 3.1(Marking, Cl.9 of IS 7809 (Part 1):1975) |
- |
10 |
|
- |
| 3.1(Marking, Cl.9 of IS 7809 (Part 1):1975) |
- |
10 |
|
- |
| 3.1(Marking, Cl.9 of IS 7809 (Part 1):1975) |
- |
10 |
|
- |
| 3.1(Marking, Cl.9 of IS 7809 (Part 1):1975) |
- |
10 |
|
- |
| 2.1.1(Type and Desiganation) |
- |
10 |
|
- |
| 2.1.2(Type and Desiganation) |
- |
10 |
|
- |
| 3.1(General Requirments,as per IS 7809 (Part 1 ) :1975 ) |
- |
10 |
|
- |
| 3.2(General Requirments,as per IS 7809 (Part 1 ) :1975 ) |
- |
10 |
|
- |
| 3.3(General Requirments,as per IS 7809 (Part 1 ) :1975 ) |
- |
10 |
|
- |
| 3.4(General Requirments,as per IS 7809 (Part 1 ) :1975 ) |
- |
10 |
|
- |
| 4.1(Performance Requirments) |
- |
0 |
|
- |
| 4.2(Performance Requirments) |
- |
0 |
|
- |
| 4.3(Performance Requirments) |
- |
0 |
|
- |
| 4.4(Performance Requirments) |
- |
0 |
|
- |
| 4.5(Performance Requirments) |
- |
0 |
|
- |
| 4.6(Flammability ,Cl 6 of IS 7809 (Part 2): 1977) |
- |
500 |
|
- |
| 4.6(Flammability ,Cl 6 of IS 7809 (Part 2): 1977) |
- |
0 |
|
- |
| 4.6(Flammability ,Cl 6 of IS 7809 (Part 2): 1977) |
- |
0 |
|
- |
| 4.6(Flammability ,Cl 6 of IS 7809 (Part 2): 1977) |
- |
0 |
|
- |
| 4.7(Electrolytic corrosion) |
- |
3000 |
|
- |
| 4.7(Electrolytic corrosion) |
- |
0 |
|
- |
| 4.7(Electrolytic corrosion) |
- |
0 |
|
- |
| 4.8(Stability to accelerated ageing ) |
- |
800 |
|
- |
| 4.9(Insulation resistance test) |
- |
750 |
|
- |
| 3.1( Minimum Storage Life Cl. 7.1 of IS 7809(Part 1) :1975) |
- |
0 |
|
- |
| 3.1( Minimum Storage Life Cl. 7.1 of IS 7809(Part 1) :1975) |
- |
0 |
|
- |
| 3.1( Minimum Storage Life Cl. 7.1 of IS 7809(Part 1) :1975) |
- |
0 |
|
- |
| 3.1(Minimum Storage Life ,Dimensions , Cl. 7.1 of IS 7809(Part 1) :1975) |
- |
0 |
|
- |
| 3.1(Minimum Storage Life ,Dimensions , Cl. 7.1 of IS 7809(Part 1) :1975) |
- |
0 |
|
- |
| 3.1(Minimum Storage Life ,Dimensions , Cl. 7.1 of IS 7809(Part 1) :1975) |
- |
0 |
|
- |
| 3.1(Minimum Storage Life ,Dimensions , Cl. 7.1 of IS 7809(Part 1) :1975) |
- |
0 |
|
- |
| 3.1(Marking, Cl.9 of IS 7809 (Part 1):1975) |
- |
0 |
|
- |
| 3.1(Marking, Cl.9 of IS 7809 (Part 1):1975) |
- |
0 |
|
- |
| 3.1(Marking, Cl.9 of IS 7809 (Part 1):1975) |
- |
10 |
|
- |
| 3.1(Marking, Cl.9 of IS 7809 (Part 1):1975) |
- |
10 |
|
- |
| 3.1(Marking, Cl.9 of IS 7809 (Part 1):1975) |
- |
10 |
|
- |
| 3.1(Marking, Cl.9 of IS 7809 (Part 1):1975) |
- |
10 |
|
- |
| 3.1(Marking, Cl.9 of IS 7809 (Part 1):1975) |
- |
10 |
|
- |
| 3.1(Marking, Cl.9 of IS 7809 (Part 1):1975) |
- |
10 |
|
- |
| 2.1.1(Type and Desiganation) |
- |
10 |
|
- |
| 2.1.2(Type and Desiganation) |
- |
10 |
|
- |
| 3.1(General Requirments,as per IS 7809 (Part 1 ) :1975 ) |
- |
10 |
|
- |
| 3.2(General Requirments,as per IS 7809 (Part 1 ) :1975 ) |
- |
10 |
|
- |
| 3.3(General Requirments,as per IS 7809 (Part 1 ) :1975 ) |
- |
10 |
|
- |
| 3.4(General Requirments,as per IS 7809 (Part 1 ) :1975 ) |
- |
10 |
|
- |
| 4.1(Performance Requirments) |
- |
0 |
|
- |
| 4.2(Performance Requirments) |
- |
0 |
|
- |
| 4.3(Performance Requirments) |
- |
0 |
|
- |
| 4.4(Performance Requirments) |
- |
0 |
|
- |
| 4.5(Performance Requirments) |
- |
0 |
|
- |
| 4.6(Flammability ,Cl 6 of IS 7809 (Part 2): 1977) |
- |
0 |
|
- |
| 4.6(Flammability ,Cl 6 of IS 7809 (Part 2): 1977) |
- |
0 |
|
- |
| 4.6(Flammability ,Cl 6 of IS 7809 (Part 2): 1977) |
- |
0 |
|
- |
| 4.6(Flammability ,Cl 6 of IS 7809 (Part 2): 1977) |
- |
0 |
|
- |
| 4.7(Electrolytic corrosion) |
- |
0 |
|
- |
| 4.7(Electrolytic corrosion) |
- |
0 |
|
- |
| 4.7(Electrolytic corrosion) |
- |
0 |
|
- |
| 4.8(Stability to accelerated ageing ) |
- |
800 |
|
- |
| 4.9(Insulation resistance test) |
- |
750 |
|
- |
| 3.1( Minimum Storage Life Cl. 7.1 of IS 7809(Part 1) :1975) |
- |
1000 |
|
- |
| 3.1(Appearance) |
- |
1000 |
|
- |
| 3.1(Freedom from defects) |
- |
1000 |
|
- |
| 3.1(Minimum Storage Life ,Dimensions , Cl. 7.1 of IS 7809(Part 1) :1975) |
- |
1000 |
|
- |
| 3.1(Minimum Storage Life ,Dimensions , Cl. 7.1 of IS 7809(Part 1) :1975) |
- |
1000 |
|
- |
| 3.1(Minimum Storage Life ,Dimensions , Cl. 7.1 of IS 7809(Part 1) :1975) |
- |
1000 |
|
- |
| 3.1(Minimum Storage Life ,Dimensions , Cl. 7.1 of IS 7809(Part 1) :1975) |
- |
1000 |
|
- |
| Cl.No.4 of IS 7809 (Part 1)-1975(Appearance) |
- |
500 |
|
- |
| Cl.No.5 of IS 7809 (Part 1)-1975(Freedom From Deffects) |
- |
50 |
|
- |
| Cl.No.3.2(Width) |
- |
250 |
|
- |
| Cl.No.3.3(Length) |
- |
250 |
|
- |
| Cl.No.3.4(Thickness) |
- |
250 |
|
- |
| Cl.No.4.1(Tensile Strength) |
- |
750 |
|
- |
| Cl.No.4.2(Adhesion to Steel) |
- |
750 |
|
- |
| Cl.No.4.3(Adhesion to backing) |
- |
750 |
|
- |
| Cl.No.4.4(Electric Strength at RT) |
- |
750 |
|
- |
| Cl.No.4.5(Electric Strength after Humid Conditioning) |
- |
750 |
|
- |
| Cl.No.4.6(Flammability) |
- |
0 |
|
- |
| Cl.No.4.7() |
- |
0 |
|
- |
| Cl.No.4.8(Stability to accelerated ageing) |
- |
0 |
|
- |
| Cl.No.4.9(Insulation Resistance) |
- |
0 |
|
- |
| Cl.No.7 of IS 7809 (Part 1)-1975(Minimum Storage Life) |
- |
1000 |
|
- |
| Cl.No.4 of IS 7809 (Part 1)-1975(Appearance after minimum storage Life) |
- |
1000 |
|
- |
| Cl.No.5 of IS 7809 (Part 1)-1975(Freedom From Deffects after minimum storage Life) |
- |
0 |
|
- |
| Cl.No.3.2(Width after minimum storage Life) |
- |
0 |
|
- |
| Cl.No.3.3(Length after minimum storage Life) |
- |
0 |
|
- |
| Cl.No.3.4(Thickness after minimum storage Life) |
- |
0 |
|
- |
| Cl.No.4.1(Tensile Strength after minimum storage Life) |
- |
0 |
|
- |
| Cl.No.4.2(Adhesion to Steel after minimum storage Life) |
- |
0 |
|
- |
| Cl.No.4.3(Adhesion to backing after minimum storage Life) |
- |
0 |
|
- |
| Cl.No.4.4(Electric Strength at RT after minimum storage Life) |
- |
0 |
|
- |
| Cl.No.4.5(Electric Strength after Humid Conditioning after minimum storage Life) |
- |
0 |
|
- |
| Cl.No.4.6(Flammability after minimum storage Life) |
- |
0 |
|
- |
| Cl.No.4.7(Electrolytic Corrosion after minimum storage Life) |
- |
0 |
|
- |
| Cl.No.4.8(Stability to accelerated ageing after minimum storage Life) |
- |
0 |
|
- |
| Cl.No.4.9(Insulation Resistance after minimum storage Life) |
- |
0 |
|
- |
| 3.1(Marking) |
- |
0 |
|
- |
| 3.1(Marking, Cl.9 of IS 7809 (Part 1):1975) |
- |
0 |
|
- |
| 3.1(Marking, Cl.9 of IS 7809 (Part 1):1975) |
- |
0 |
|
- |
| 3.1(Marking, Cl.9 of IS 7809 (Part 1):1975) |
- |
0 |
|
- |
| 3.1(Marking, Cl.9 of IS 7809 (Part 1):1975) |
- |
0 |
|
- |
| 3.1(Marking, Cl.9 of IS 7809 (Part 1):1975) |
- |
0 |
|
- |
| 3.1(Marking, Cl.9 of IS 7809 (Part 1):1975) |
- |
0 |
|
- |
| 3.1(Marking, Cl.9 of IS 7809 (Part 1):1975) |
- |
0 |
|
- |
| 3.1(Marking, Cl.9 of IS 7809 (Part 1):1975) |
- |
0 |
|
- |
| 3.1(Marking, Cl.9 of IS 7809 (Part 1):1975) |
- |
0 |
|
- |
| 2.1.1(Type and Desiganation) |
- |
0 |
|
- |
| 2.1.2(Type and Desiganation) |
- |
0 |
|
- |
| 3.1(General Requirments,as per IS 7809 (Part 1 ) :1975 ) |
- |
0 |
|
- |
| 3.2(General Requirments,as per IS 7809 (Part 1 ) :1975 ) |
- |
0 |
|
- |
| 3.3(General Requirments,as per IS 7809 (Part 1 ) :1975 ) |
- |
0 |
|
- |
| 3.4(General Requirments,as per IS 7809 (Part 1 ) :1975 ) |
- |
0 |
|
- |
| 4.1(Performance Requirments) |
- |
0 |
|
- |
| 4.2(Performance Requirments) |
- |
0 |
|
- |
| 4.3(Performance Requirments) |
- |
0 |
|
- |
| 4.4(Performance Requirments) |
- |
0 |
|
- |
| 4.5(Performance Requirments) |
- |
0 |
|
- |
| 4.6(Flammability ,Cl 6 of IS 7809 (Part 2): 1977) |
- |
0 |
|
- |
| 4.6(Flammability ,Cl 6 of IS 7809 (Part 2): 1977) |
- |
0 |
|
- |
| 4.6(Flammability ,Cl 6 of IS 7809 (Part 2): 1977) |
- |
0 |
|
- |
| 4.6(Flammability ,Cl 6 of IS 7809 (Part 2): 1977) |
- |
0 |
|
- |
| 4.7(Electrolytic corrosion) |
- |
0 |
|
- |
| 4.7(Electrolytic corrosion) |
- |
0 |
|
- |
| 4.7(Electrolytic corrosion) |
- |
0 |
|
- |
| 4.8(Stability to accelerated ageing ) |
- |
0 |
|
- |
| 4.9(Insulation resistance test) |
- |
0 |
|
- |
| 3.1( Minimum Storage Life Cl. 7.1 of IS 7809(Part 1) :1975) |
- |
0 |
|
- |
| 3.1( Minimum Storage Life Cl. 7.1 of IS 7809(Part 1) :1975) |
- |
0 |
|
- |
| 3.1( Minimum Storage Life Cl. 7.1 of IS 7809(Part 1) :1975) |
- |
0 |
|
- |
| 3.1(Minimum Storage Life ,Dimensions , Cl. 7.1 of IS 7809(Part 1) :1975) |
- |
0 |
|
- |
| 3.1(Minimum Storage Life ,Dimensions , Cl. 7.1 of IS 7809(Part 1) :1975) |
- |
0 |
|
- |
| 3.1(Minimum Storage Life ,Dimensions , Cl. 7.1 of IS 7809(Part 1) :1975) |
- |
0 |
|
- |
| 3.1(Minimum Storage Life ,Dimensions , Cl. 7.1 of IS 7809(Part 1) :1975) |
- |
0 |
|
- |
| 3.1(Marking, Cl.9 of IS 7809 (Part 1):1975) |
- |
0 |
|
- |
| 3.1(Marking, Cl.9 of IS 7809 (Part 1):1975) |
- |
0 |
|
- |
| 3.1(Marking, Cl.9 of IS 7809 (Part 1):1975) |
- |
0 |
|
- |
| 3.1(Marking, Cl.9 of IS 7809 (Part 1):1975) |
- |
0 |
|
- |
| 3.1(Marking, Cl.9 of IS 7809 (Part 1):1975) |
- |
0 |
|
- |
| 3.1(Marking, Cl.9 of IS 7809 (Part 1):1975) |
- |
0 |
|
- |
| 3.1(Marking, Cl.9 of IS 7809 (Part 1):1975) |
- |
0 |
|
- |
| 3.1(Marking, Cl.9 of IS 7809 (Part 1):1975) |
- |
0 |
|
- |
| 2.1.1(Type and Desiganation) |
- |
0 |
|
- |
| 2.1.2(Type and Desiganation) |
- |
0 |
|
- |
| 3.1(General Requirments,as per IS 7809 (Part 1 ) :1975 ) |
- |
0 |
|
- |
| 3.2(General Requirments,as per IS 7809 (Part 1 ) :1975 ) |
- |
0 |
|
- |
| 3.3(General Requirments,as per IS 7809 (Part 1 ) :1975 ) |
- |
0 |
|
- |
| 3.4(General Requirments,as per IS 7809 (Part 1 ) :1975 ) |
- |
0 |
|
- |
| 4.1(Performance Requirments) |
- |
0 |
|
- |
| 4.2(Performance Requirments) |
- |
0 |
|
- |
| 4.3(Performance Requirments) |
- |
0 |
|
- |
| 4.4(Performance Requirments) |
- |
0 |
|
- |
| 4.5(Performance Requirments) |
- |
0 |
|
- |
| 4.6(Flammability ,Cl 6 of IS 7809 (Part 2): 1977) |
- |
0 |
|
- |
| 4.6(Flammability ,Cl 6 of IS 7809 (Part 2): 1977) |
- |
0 |
|
- |
| 4.6(Flammability ,Cl 6 of IS 7809 (Part 2): 1977) |
- |
0 |
|
- |
| 4.6(Flammability ,Cl 6 of IS 7809 (Part 2): 1977) |
- |
0 |
|
- |
| 4.7(Electrolytic corrosion) |
- |
0 |
|
- |
| 4.7(Electrolytic corrosion) |
- |
0 |
|
- |
| 4.7(Electrolytic corrosion) |
- |
0 |
|
- |
| 4.8(Stability to accelerated ageing ) |
- |
0 |
|
- |
| 4.9(Insulation resistance test) |
- |
0 |
|
- |
| 3.1( Minimum Storage Life Cl. 7.1 of IS 7809(Part 1) :1975) |
- |
0 |
|
- |
| 3.1(Appearance) |
- |
0 |
|
- |
| 3.1(Freedom from defects) |
- |
0 |
|
- |
| 3.1(Minimum Storage Life ,Dimensions , Cl. 7.1 of IS 7809(Part 1) :1975) |
- |
0 |
|
- |
| 3.1(Minimum Storage Life ,Dimensions , Cl. 7.1 of IS 7809(Part 1) :1975) |
- |
0 |
|
- |
| 3.1(Minimum Storage Life ,Dimensions , Cl. 7.1 of IS 7809(Part 1) :1975) |
- |
0 |
|
- |
| 3.1(Minimum Storage Life ,Dimensions , Cl. 7.1 of IS 7809(Part 1) :1975) |
- |
0 |
|
- |
| Cl.No.4 of IS 7809 (Part 1)-1975(Appearance) |
- |
0 |
|
- |
| Cl.No.5 of IS 7809 (Part 1)-1975(Freedom From Deffects) |
- |
0 |
|
- |
| Cl.No.3.2(Width) |
- |
0 |
|
- |
| Cl.No.3.3(Length) |
- |
0 |
|
- |
| Cl.No.3.4(Thickness) |
- |
0 |
|
- |
| Cl.No.4.1(Tensile Strength) |
- |
0 |
|
- |
| Cl.No.4.2(Adhesion to Steel) |
- |
0 |
|
- |
| Cl.No.4.3(Adhesion to backing) |
- |
0 |
|
- |
| Cl.No.4.4(Electric Strength at RT) |
- |
0 |
|
- |
| Cl.No.4.5(Electric Strength after Humid Conditioning) |
- |
0 |
|
- |
| Cl.No.4.6(Flammability) |
- |
0 |
|
- |
| Cl.No.4.7() |
- |
0 |
|
- |
| Cl.No.4.8(Stability to accelerated ageing) |
- |
0 |
|
- |
| Cl.No.4.9(Insulation Resistance) |
- |
0 |
|
- |
| Cl.No.7 of IS 7809 (Part 1)-1975(Minimum Storage Life) |
- |
0 |
|
- |
| Cl.No.4 of IS 7809 (Part 1)-1975(Appearance after minimum storage Life) |
- |
0 |
|
- |
| Cl.No.5 of IS 7809 (Part 1)-1975(Freedom From Deffects after minimum storage Life) |
- |
0 |
|
- |
| Cl.No.3.2(Width after minimum storage Life) |
- |
0 |
|
- |
| Cl.No.3.3(Length after minimum storage Life) |
- |
0 |
|
- |
| Cl.No.3.4(Thickness after minimum storage Life) |
- |
0 |
|
- |
| Cl.No.4.1(Tensile Strength after minimum storage Life) |
- |
0 |
|
- |
| Cl.No.4.2(Adhesion to Steel after minimum storage Life) |
- |
0 |
|
- |
| Cl.No.4.3(Adhesion to backing after minimum storage Life) |
- |
0 |
|
- |
| Cl.No.4.4(Electric Strength at RT after minimum storage Life) |
- |
0 |
|
- |
| Cl.No.4.5(Electric Strength after Humid Conditioning after minimum storage Life) |
- |
0 |
|
- |
| Cl.No.4.6(Flammability after minimum storage Life) |
- |
0 |
|
- |
| Cl.No.4.7(Electrolytic Corrosion after minimum storage Life) |
- |
0 |
|
- |
| Cl.No.4.8(Stability to accelerated ageing after minimum storage Life) |
- |
0 |
|
- |
| Cl.No.4.9(Insulation Resistance after minimum storage Life) |
- |
0 |
|
- |
| 3.1(Marking) |
- |
0 |
|
- |
| 3.1(Marking, Cl.9 of IS 7809 (Part 1):1975) |
- |
- |
|
- |
| 3.1(Marking, Cl.9 of IS 7809 (Part 1):1975) |
- |
- |
|
- |
| 3.1(Marking, Cl.9 of IS 7809 (Part 1):1975) |
- |
- |
|
- |
| 3.1(Marking, Cl.9 of IS 7809 (Part 1):1975) |
- |
- |
|
- |
| 3.1(Marking, Cl.9 of IS 7809 (Part 1):1975) |
- |
- |
|
- |
| 3.1(Marking, Cl.9 of IS 7809 (Part 1):1975) |
- |
- |
|
- |
| 3.1(Marking, Cl.9 of IS 7809 (Part 1):1975) |
- |
- |
|
- |
| 3.1(Marking, Cl.9 of IS 7809 (Part 1):1975) |
- |
- |
|
- |
| 3.1(Marking, Cl.9 of IS 7809 (Part 1):1975) |
- |
- |
|
- |
| 2.1.1(Type and Desiganation) |
- |
- |
|
- |
| 2.1.2(Type and Desiganation) |
- |
- |
|
- |
| 3.1(General Requirments,as per IS 7809 (Part 1 ) :1975 ) |
- |
- |
|
- |
| 3.2(General Requirments,as per IS 7809 (Part 1 ) :1975 ) |
- |
- |
|
- |
| 3.3(General Requirments,as per IS 7809 (Part 1 ) :1975 ) |
- |
- |
|
- |
| 3.4(General Requirments,as per IS 7809 (Part 1 ) :1975 ) |
- |
- |
|
- |
| 4.1(Performance Requirments) |
- |
- |
|
- |
| 4.2(Performance Requirments) |
- |
- |
|
- |
| 4.3(Performance Requirments) |
- |
- |
|
- |
| 4.4(Performance Requirments) |
- |
- |
|
- |
| 4.5(Performance Requirments) |
- |
- |
|
- |
| 4.6(Flammability ,Cl 6 of IS 7809 (Part 2): 1977) |
- |
- |
|
- |
| 4.6(Flammability ,Cl 6 of IS 7809 (Part 2): 1977) |
- |
- |
|
- |
| 4.6(Flammability ,Cl 6 of IS 7809 (Part 2): 1977) |
- |
- |
|
- |
| 4.6(Flammability ,Cl 6 of IS 7809 (Part 2): 1977) |
- |
- |
|
- |
| 4.7(Electrolytic corrosion) |
- |
- |
|
- |
| 4.7(Electrolytic corrosion) |
- |
- |
|
- |
| 4.7(Electrolytic corrosion) |
- |
- |
|
- |
| 4.8(Stability to accelerated ageing ) |
- |
- |
|
- |
| 4.9(Insulation resistance test) |
- |
- |
|
- |
| 3.1( Minimum Storage Life Cl. 7.1 of IS 7809(Part 1) :1975) |
- |
- |
|
- |
| 3.1( Minimum Storage Life Cl. 7.1 of IS 7809(Part 1) :1975) |
- |
- |
|
- |
| 3.1( Minimum Storage Life Cl. 7.1 of IS 7809(Part 1) :1975) |
- |
- |
|
- |
| 3.1(Minimum Storage Life ,Dimensions , Cl. 7.1 of IS 7809(Part 1) :1975) |
- |
- |
|
- |
| 3.1(Minimum Storage Life ,Dimensions , Cl. 7.1 of IS 7809(Part 1) :1975) |
- |
- |
|
- |
| 3.1(Minimum Storage Life ,Dimensions , Cl. 7.1 of IS 7809(Part 1) :1975) |
- |
- |
|
- |
| 3.1(Minimum Storage Life ,Dimensions , Cl. 7.1 of IS 7809(Part 1) :1975) |
- |
- |
|
- |
| 3.1(Marking, Cl.9 of IS 7809 (Part 1):1975) |
- |
- |
|
- |
| 3.1(Marking, Cl.9 of IS 7809 (Part 1):1975) |
- |
- |
|
- |
| 3.1(Marking, Cl.9 of IS 7809 (Part 1):1975) |
- |
- |
|
- |
| 3.1(Marking, Cl.9 of IS 7809 (Part 1):1975) |
- |
- |
|
- |
| 3.1(Marking, Cl.9 of IS 7809 (Part 1):1975) |
- |
- |
|
- |
| 3.1(Marking, Cl.9 of IS 7809 (Part 1):1975) |
- |
- |
|
- |
| 3.1(Marking, Cl.9 of IS 7809 (Part 1):1975) |
- |
- |
|
- |
| 3.1(Marking, Cl.9 of IS 7809 (Part 1):1975) |
- |
- |
|
- |
| 2.1.1(Type and Desiganation) |
- |
- |
|
- |
| 2.1.2(Type and Desiganation) |
- |
- |
|
- |
| 3.1(General Requirments,as per IS 7809 (Part 1 ) :1975 ) |
- |
- |
|
- |
| 3.2(General Requirments,as per IS 7809 (Part 1 ) :1975 ) |
- |
- |
|
- |
| 3.3(General Requirments,as per IS 7809 (Part 1 ) :1975 ) |
- |
- |
|
- |
| 3.4(General Requirments,as per IS 7809 (Part 1 ) :1975 ) |
- |
- |
|
- |
| 4.1(Performance Requirments) |
- |
- |
|
- |
| 4.2(Performance Requirments) |
- |
- |
|
- |
| 4.3(Performance Requirments) |
- |
- |
|
- |
| 4.4(Performance Requirments) |
- |
- |
|
- |
| 4.5(Performance Requirments) |
- |
- |
|
- |
| 4.6(Flammability ,Cl 6 of IS 7809 (Part 2): 1977) |
- |
- |
|
- |
| 4.6(Flammability ,Cl 6 of IS 7809 (Part 2): 1977) |
- |
- |
|
- |
| 4.6(Flammability ,Cl 6 of IS 7809 (Part 2): 1977) |
- |
- |
|
- |
| 4.6(Flammability ,Cl 6 of IS 7809 (Part 2): 1977) |
- |
- |
|
- |
| 4.7(Electrolytic corrosion) |
- |
- |
|
- |
| 4.7(Electrolytic corrosion) |
- |
- |
|
- |
| 4.7(Electrolytic corrosion) |
- |
- |
|
- |
| 4.8(Stability to accelerated ageing ) |
- |
- |
|
- |
| 4.9(Insulation resistance test) |
- |
- |
|
- |
| 3.1( Minimum Storage Life Cl. 7.1 of IS 7809(Part 1) :1975) |
- |
- |
|
- |
| 3.1(Appearance) |
- |
- |
|
- |
| 3.1(Freedom from defects) |
- |
- |
|
- |
| 3.1(Minimum Storage Life ,Dimensions , Cl. 7.1 of IS 7809(Part 1) :1975) |
- |
- |
|
- |
| 3.1(Minimum Storage Life ,Dimensions , Cl. 7.1 of IS 7809(Part 1) :1975) |
- |
- |
|
- |
| 3.1(Minimum Storage Life ,Dimensions , Cl. 7.1 of IS 7809(Part 1) :1975) |
- |
- |
|
- |
| 3.1(Minimum Storage Life ,Dimensions , Cl. 7.1 of IS 7809(Part 1) :1975) |
- |
- |
|
- |
| Cl.No.4 of IS 7809 (Part 1)-1975(Appearance) |
- |
- |
|
- |
| Cl.No.5 of IS 7809 (Part 1)-1975(Freedom From Deffects) |
- |
- |
|
- |
| Cl.No.3.2(Width) |
- |
- |
|
- |
| Cl.No.3.3(Length) |
- |
- |
|
- |
| Cl.No.3.4(Thickness) |
- |
- |
|
- |
| Cl.No.4.1(Tensile Strength) |
- |
- |
|
- |
| Cl.No.4.2(Adhesion to Steel) |
- |
- |
|
- |
| Cl.No.4.3(Adhesion to backing) |
- |
- |
|
- |
| Cl.No.4.4(Electric Strength at RT) |
- |
- |
|
- |
| Cl.No.4.5(Electric Strength after Humid Conditioning) |
- |
- |
|
- |
| Cl.No.4.6(Flammability) |
- |
- |
|
- |
| Cl.No.4.7() |
- |
- |
|
- |
| Cl.No.4.8(Stability to accelerated ageing) |
- |
- |
|
- |
| Cl.No.4.9(Insulation Resistance) |
- |
- |
|
- |
| Cl.No.7 of IS 7809 (Part 1)-1975(Minimum Storage Life) |
- |
- |
|
- |
| Cl.No.4 of IS 7809 (Part 1)-1975(Appearance after minimum storage Life) |
- |
- |
|
- |
| Cl.No.5 of IS 7809 (Part 1)-1975(Freedom From Deffects after minimum storage Life) |
- |
- |
|
- |
| Cl.No.3.2(Width after minimum storage Life) |
- |
- |
|
- |
| Cl.No.3.3(Length after minimum storage Life) |
- |
- |
|
- |
| Cl.No.3.4(Thickness after minimum storage Life) |
- |
- |
|
- |
| Cl.No.4.1(Tensile Strength after minimum storage Life) |
- |
- |
|
- |
| Cl.No.4.2(Adhesion to Steel after minimum storage Life) |
- |
- |
|
- |
| Cl.No.4.3(Adhesion to backing after minimum storage Life) |
- |
- |
|
- |
| Cl.No.4.4(Electric Strength at RT after minimum storage Life) |
- |
- |
|
- |
| Cl.No.4.5(Electric Strength after Humid Conditioning after minimum storage Life) |
- |
- |
|
- |
| Cl.No.4.6(Flammability after minimum storage Life) |
- |
- |
|
- |
| Cl.No.4.7(Electrolytic Corrosion after minimum storage Life) |
- |
- |
|
- |
| Cl.No.4.8(Stability to accelerated ageing after minimum storage Life) |
- |
- |
|
- |
| Cl.No.4.9(Insulation Resistance after minimum storage Life) |
- |
- |
|
- |
| 3.1(Marking) |
- |
- |
|
- |
|
- |
- Included w.e.f. 17.11.2023 |
| 7725 |
Alpha Test House Private Limited, Delhi
| 8131026
| IS 4289 : Part 2 (2000) |
Flexible cables for lifts and other flexible connections - Specification: Part 2 pvc insulated circular cables |
- |
21000.00 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4(Conductor) |
- |
2000 |
|
- |
| 5(Separator) |
- |
100 |
|
- |
| 6(Insulation) |
- |
2500 |
|
- |
| 7(Central heart) |
- |
100 |
|
- |
| 8(Fillers) |
- |
100 |
|
- |
| 9(tape) |
- |
100 |
|
- |
| 10(braid) |
- |
100 |
|
- |
| 11(sheath) |
- |
100 |
|
- |
| 12(GENERAL DETAILS OF CONSTRUCTION) |
- |
100 |
|
- |
| 13(Construction- Conductor) |
- |
100 |
|
- |
| 14(Construction- Insulation) |
- |
100 |
|
- |
| 14.2(Thickness of Insulation) |
- |
500 |
|
- |
| 14.3(Tolerance on Thickness of Insulation) |
- |
500 |
|
- |
| 15(Core identification) |
- |
100 |
|
- |
| 16(Core assembly) |
- |
100 |
|
- |
| 17(overall covering) |
- |
100 |
|
- |
| 17.1.1(Thickness of Sheath) |
- |
100 |
|
- |
| 17.1.2(Tolerance on Thickness of Sheath) |
- |
500 |
|
- |
| 4(Conductor) |
- |
0 |
|
- |
| 5(Separator) |
- |
0 |
|
- |
| 6(Insulation) |
- |
0 |
|
- |
| 7(Central heart) |
- |
0 |
|
- |
| 8(Fillers) |
- |
0 |
|
- |
| 9(tape) |
- |
0 |
|
- |
| 10(braid) |
- |
0 |
|
- |
| 11(sheath) |
- |
0 |
|
- |
| 12(GENERAL DETAILS OF CONSTRUCTION) |
- |
0 |
|
- |
| 13(Construction- Conductor) |
- |
0 |
|
- |
| 14(Construction- Insulation) |
- |
0 |
|
- |
| 14.2(Thickness of Insulation) |
- |
0 |
|
- |
| 14.3(Tolerance on Thickness of Insulation) |
- |
0 |
|
- |
| 15(Core identification) |
- |
0 |
|
- |
| 16(Core assembly) |
- |
0 |
|
- |
| 17(overall covering) |
- |
0 |
|
- |
| 17.1.1(Thickness of Sheath) |
- |
0 |
|
- |
| 17.1.2(Tolerance on Thickness of Sheath) |
- |
0 |
|
- |
| 18.1.a.i(IS 10810 Part-1) |
- |
0 |
|
- |
| 18.1.a.ii(IS 10810 Part-5) |
- |
0 |
|
- |
| 18.1.b(IS 10810 Part-6) |
- |
0 |
|
- |
| 18.1.c.i(IS 10810 Part-7) |
- |
0 |
|
- |
| 18.1.c.i(IS 10810 Part-7) |
- |
0 |
|
- |
| 18.1.c.ii(IS 10810 Part-11) |
- |
0 |
|
- |
| 18.1.c.ii(IS 10810 Part-11) |
- |
0 |
|
- |
| 18.1.c.iii(IS 10810 Part-10) |
- |
0 |
|
- |
| 18.1.c.iii(IS 10810 Part-10) |
- |
0 |
|
- |
| 18.1.c.iv(IS 10810 Part-14) |
- |
0 |
|
- |
| 18.1.c.iv(IS 10810 Part-14) |
- |
0 |
|
- |
| 18.1.c.v(IS 10810 Part-12) |
- |
0 |
|
- |
| 18.1.c.v(IS 10810 Part-12) |
- |
0 |
|
- |
| 18.1.c.vi(IS 10810 Part-60) |
- |
0 |
|
- |
| 18.1.c.vi(IS 10810 Part-60) |
- |
0 |
|
- |
| 18.1.d(IS 10810 Part-45) |
- |
0 |
|
- |
| 18.1.e(IS 10810 Part-43) |
- |
0 |
|
- |
| 18.1. f(IS 10810 Part-54) |
- |
0 |
|
- |
| 18.1.g(IS 10810 Part-53) |
- |
0 |
|
- |
|
- |
- Included w.e.f. 17.11.2023 |
| 7726 |
Alpha Test House Private Limited, Delhi
| 8131026
| IS 4289 : Part 1 (1984) |
Specification for flexible cables for lifts and other flexible connections: Part 1 elastomer insulated cables (First Revision) |
- |
30000.00 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 3(Conductor) |
- |
100 |
|
- |
| 4(Separator) |
- |
100 |
|
- |
| 5(Insulation) |
- |
100 |
|
- |
| 5(Central heart) |
- |
100 |
|
- |
| 7(Fillers) |
- |
100 |
|
- |
| 8(Proofed tape) |
- |
100 |
|
- |
| 9(Braid) |
- |
100 |
|
- |
| 10(Sheath) |
- |
100 |
|
- |
| 11(GENERAL DETAILS OF CONSTRUCTION) |
- |
100 |
|
- |
| 12(Conductor) |
- |
100 |
|
- |
| 13(Insulation) |
- |
100 |
|
- |
| 14(Core identification) |
- |
100 |
|
- |
| 15(Core assembly) |
- |
100 |
|
- |
| 16.1(Overall covering- sheathed cables) |
- |
100 |
|
- |
| 16.2(overall covering- braided cables) |
- |
100 |
|
- |
| 17.1.a(Persulphate test) |
- |
0 |
|
- |
| 17.1.b(Annealing test) |
- |
0 |
|
- |
| 17.1.c(Conductor resistance test) |
- |
0 |
|
- |
| 17.1.d(Test for thickness of insulation and sheath) |
- |
0 |
|
- |
| 17.1.e.1(Tensile strength and elongation at break for insulation) |
- |
0 |
|
- |
| 17.1.f.1(Tensile strength and elongation at break for Sheath) |
- |
0 |
|
- |
| 17.1.e.2(Ageing in air oven for insulation) |
- |
0 |
|
- |
| 17.1.e.3(Ageing in oxygen bomb for insulation) |
- |
0 |
|
- |
| 17.1.f.2(Ageing in air bomb for sheath) |
- |
0 |
|
- |
| 17.1.f.3(Oil resistance for sheath) |
- |
0 |
|
- |
| 17.1.f.4(Tear resistance) |
- |
0 |
|
- |
| 17.1.g(High voltage water immersion test) |
- |
0 |
|
- |
| 17.1.h(Insulation resistance test) |
- |
0 |
|
- |
| 17.1.j(Static flexibility test) |
- |
0 |
|
- |
| 17.1.k(Flammability test) |
- |
0 |
|
- |
| 17.1.a(Persulphate test) |
- |
1500 |
|
- |
| 17.1.b(Annealing test) |
- |
1000 |
|
- |
| 17.1.c(Conductor resistance test) |
- |
2000 |
|
- |
| 17.1.d(Test for thickness of insulation and sheath) |
- |
1000 |
|
- |
| 17.1.e.1(Tensile strength and elongation at break for insulation) |
- |
1000 |
|
- |
| 17.1.f.1(Tensile strength and elongation at break for Sheath) |
- |
1000 |
|
- |
| 17.1.e.2(Ageing in air oven for insulation) |
- |
3500 |
|
- |
| 17.1.e.3(Ageing in oxygen bomb for insulation) |
- |
3500 |
|
- |
| 17.1.f.2(Ageing in air bomb for sheath) |
- |
3000 |
|
- |
| 17.1.f.3(Oil resistance for sheath) |
- |
3000 |
|
- |
| 17.1.f.4(Tear resistance) |
- |
1500 |
|
- |
| 17.1.g(High voltage water immersion test) |
- |
2000 |
|
- |
| 17.1.h(Insulation resistance test) |
- |
2500 |
|
- |
| 17.1.j(Static flexibility test) |
- |
1500 |
|
- |
| 17.1.k(Flammability test) |
- |
500 |
|
- |
| 3(Conductor) |
- |
0 |
|
- |
| 4(Separator) |
- |
0 |
|
- |
| 5(Insulation) |
- |
0 |
|
- |
| 5(Central heart) |
- |
0 |
|
- |
| 7(Fillers) |
- |
0 |
|
- |
| 8(Proofed tape) |
- |
0 |
|
- |
| 9(Braid) |
- |
0 |
|
- |
| 10(Sheath) |
- |
0 |
|
- |
| 11(GENERAL DETAILS OF CONSTRUCTION) |
- |
0 |
|
- |
| 12(Conductor) |
- |
0 |
|
- |
| 13(Insulation) |
- |
0 |
|
- |
| 14(Core identification) |
- |
0 |
|
- |
| 15(Core assembly) |
- |
0 |
|
- |
| 16.1(Overall covering- sheathed cables) |
- |
0 |
|
- |
| 16.2(overall covering- braided cables) |
- |
0 |
|
- |
| 17.1.a(Persulphate test) |
- |
0 |
|
- |
| 17.1.b(Annealing test) |
- |
0 |
|
- |
| 17.1.c(Conductor resistance test) |
- |
0 |
|
- |
| 17.1.d(Test for thickness of insulation and sheath) |
- |
0 |
|
- |
| 17.1.e.1(Tensile strength and elongation at break for insulation) |
- |
0 |
|
- |
| 17.1.f.1(Tensile strength and elongation at break for Sheath) |
- |
0 |
|
- |
| 17.1.e.2(Ageing in air oven for insulation) |
- |
0 |
|
- |
| 17.1.e.3(Ageing in oxygen bomb for insulation) |
- |
0 |
|
- |
| 17.1.f.2(Ageing in air bomb for sheath) |
- |
0 |
|
- |
| 17.1.f.3(Oil resistance for sheath) |
- |
0 |
|
- |
| 17.1.f.4(Tear resistance) |
- |
0 |
|
- |
| 17.1.g(High voltage water immersion test) |
- |
0 |
|
- |
| 17.1.h(Insulation resistance test) |
- |
0 |
|
- |
| 17.1.j(Static flexibility test) |
- |
0 |
|
- |
| 17.1.k(Flammability test) |
- |
0 |
|
- |
| 17.1.a(Persulphate test) |
- |
0 |
|
- |
| 17.1.b(Annealing test) |
- |
0 |
|
- |
| 17.1.c(Conductor resistance test) |
- |
0 |
|
- |
| 17.1.d(Test for thickness of insulation and sheath) |
- |
0 |
|
- |
| 17.1.e.1(Tensile strength and elongation at break for insulation) |
- |
0 |
|
- |
| 17.1.f.1(Tensile strength and elongation at break for Sheath) |
- |
0 |
|
- |
| 17.1.e.2(Ageing in air oven for insulation) |
- |
0 |
|
- |
| 17.1.e.3(Ageing in oxygen bomb for insulation) |
- |
0 |
|
- |
| 17.1.f.2(Ageing in air bomb for sheath) |
- |
0 |
|
- |
| 17.1.f.3(Oil resistance for sheath) |
- |
0 |
|
- |
| 17.1.f.4(Tear resistance) |
- |
0 |
|
- |
| 17.1.g(High voltage water immersion test) |
- |
0 |
|
- |
| 17.1.h(Insulation resistance test) |
- |
0 |
|
- |
| 17.1.j(Static flexibility test) |
- |
0 |
|
- |
| 17.1.k(Flammability test) |
- |
0 |
|
- |
|
- |
- Included w.e.f. 17.11.2023 |
| 7727 |
Alpha Test House Private Limited, Delhi
| 8131026
| IS 5950 (1984) |
Specification for shot firing cables (For Use Other Than In Shafts) (First Revision) |
- |
10000.00 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 3.1(Conductor : Material -IS : 8130-2013) |
- |
50 |
|
- |
| 4.1(Insulation : Material -IS : 5831-1984) |
- |
50 |
|
- |
| 5.1(Sheath : materail IS : 5831-1984) |
- |
50 |
|
- |
| 6.1(Conductor : Construction IS : 8130-2013) |
- |
50 |
|
- |
| 7.1(Insulation : Application ) |
- |
50 |
|
- |
| 7.2(Thickness of Insulation - average ) |
- |
50 |
|
- |
| 7.2(Thickness of Insulation - Min. ) |
- |
375 |
|
- |
| 7.3(Colour of Insulation) |
- |
50 |
|
- |
| 8.1, 9.1 (c)(Nominal radial thickness of sheath) |
- |
50 |
|
- |
| 8.2(Thickness of Sheath) |
- |
375 |
|
- |
| 8.2(Thickness of Sheath - min.) |
- |
375 |
|
- |
| 8.3(Colour of Sheath) |
- |
50 |
|
- |
| 9.1 a)(Annealing test) |
- |
500 |
|
- |
| 9.1 b)(Conductor resistance test) |
- |
1000 |
|
- |
| 9.1 d) i)(Insulation : Tensile strength) |
- |
500 |
|
- |
| 9.1 d) i)(Insulation : elongation at break) |
- |
500 |
|
- |
| 9.1 d) i)(Sheath : Tensile strength) |
- |
500 |
|
- |
| 9.1 d) i)(Sheath : elongation at break) |
- |
500 |
|
- |
| 9.1 d) ii)(Ageing in air oven - Insulation : Tensile strength) |
- |
250 |
|
- |
| 9.1 d) ii)(Ageing in air oven - Insulation : Tensile strength Variation) |
- |
250 |
|
- |
| 9.1 d) ii)(Ageing in air oven - Insulation : elongation at break) |
- |
250 |
|
- |
| 9.1 d) ii)(Ageing in air oven - Insulation : elongation variation at break) |
- |
250 |
|
- |
| 9.1 d) ii)(Ageing in air oven - Sheath : Tensile strength) |
- |
250 |
|
- |
| 9.1 d) ii)(Ageing in air oven - Sheath : Tensile strength variation ) |
- |
250 |
|
- |
| 9.1 d) ii)(Ageing in air oven - Sheath : elongation at break) |
- |
250 |
|
- |
| 9.1 d) ii)(Ageing in air oven - Sheath : elongation variation at break) |
- |
250 |
|
- |
| 9.1 d) iii )(Loss of mass test - insulation ) |
- |
500 |
|
- |
| 9.1 d) iii )(Loss of mass test - Sheath ) |
- |
500 |
|
- |
| 9.1 d) iv )(Hot deformation - insulation ) |
- |
500 |
|
- |
| 9.1 d) iv )(Hot deformation - sheath ) |
- |
500 |
|
- |
| 9.1 d) v )(Heat shock - insulation ) |
- |
250 |
|
- |
| 9.1 d) v )(Heat shock - Sheath ) |
- |
250 |
|
- |
| 9.1 d) vi )(Shrinkage - insulation ) |
- |
250 |
|
- |
| 9.1 d) vi )(Shrinkage : Crack observed - insulation ) |
- |
250 |
|
- |
| 9.1 d) vi )(Shrinkage - Sheath ) |
- |
250 |
|
- |
| 9.1 d) vi )(Shrinkage: Crack observed - Sheath ) |
- |
250 |
|
- |
| 10.2(Voltage test ) |
- |
1000 |
|
- |
| 9.1 f)(Insulation resistance test: Volume resistivity ) |
- |
500 |
|
- |
| 9.1 f)(Insulation resistance test : IR constant) |
- |
500 |
|
- |
| 10.4(Flammability Test ) |
- |
500 |
|
- |
| 11.1(Manufacturer’s Identification) |
- |
50 |
|
- |
| 11.2(Cable Code) |
- |
50 |
|
- |
| 12.1(packing ) |
- |
50 |
|
- |
| 12.2(Marking ) |
- |
50 |
|
- |
| 12.2.1(Standard marks ) |
- |
50 |
|
- |
| 3.1(Conductor : Material -IS : 8130-2013) |
- |
0 |
|
- |
| 4.1(Insulation : Material -IS : 5831-1984) |
- |
0 |
|
- |
| 5.1(Sheath : materail IS : 5831-1984) |
- |
0 |
|
- |
| 6.1(Conductor : Construction IS : 8130-2013) |
- |
0 |
|
- |
| 7.1(Insulation : Application ) |
- |
0 |
|
- |
| 7.2(Thickness of Insulation - average ) |
- |
0 |
|
- |
| 7.2(Thickness of Insulation - Min. ) |
- |
0 |
|
- |
| 7.3(Colour of Insulation) |
- |
0 |
|
- |
| 8.1, 9.1 (c)(Nominal radial thickness of sheath) |
- |
0 |
|
- |
| 8.2(Thickness of Sheath) |
- |
0 |
|
- |
| 8.2(Thickness of Sheath - min.) |
- |
0 |
|
- |
| 8.3(Colour of Sheath) |
- |
0 |
|
- |
| 9.1 a)(Annealing test) |
- |
0 |
|
- |
| 9.1 b)(Conductor resistance test) |
- |
0 |
|
- |
| 9.1 d) i)(Insulation : Tensile strength) |
- |
0 |
|
- |
| 9.1 d) i)(Insulation : elongation at break) |
- |
0 |
|
- |
| 9.1 d) i)(Sheath : Tensile strength) |
- |
0 |
|
- |
| 9.1 d) i)(Sheath : elongation at break) |
- |
0 |
|
- |
| 9.1 d) ii)(Ageing in air oven - Insulation : Tensile strength) |
- |
0 |
|
- |
| 9.1 d) ii)(Ageing in air oven - Insulation : Tensile strength Variation) |
- |
0 |
|
- |
| 9.1 d) ii)(Ageing in air oven - Insulation : elongation at break) |
- |
0 |
|
- |
| 9.1 d) ii)(Ageing in air oven - Insulation : elongation variation at break) |
- |
0 |
|
- |
| 9.1 d) ii)(Ageing in air oven - Sheath : Tensile strength) |
- |
0 |
|
- |
| 9.1 d) ii)(Ageing in air oven - Sheath : Tensile strength variation ) |
- |
0 |
|
- |
| 9.1 d) ii)(Ageing in air oven - Sheath : elongation at break) |
- |
0 |
|
- |
| 9.1 d) ii)(Ageing in air oven - Sheath : elongation variation at break) |
- |
0 |
|
- |
| 9.1 d) iii )(Loss of mass test - insulation ) |
- |
0 |
|
- |
| 9.1 d) iii )(Loss of mass test - Sheath ) |
- |
0 |
|
- |
| 9.1 d) iv )(Hot deformation - insulation ) |
- |
0 |
|
- |
| 9.1 d) iv )(Hot deformation - sheath ) |
- |
0 |
|
- |
| 9.1 d) v )(Heat shock - insulation ) |
- |
0 |
|
- |
| 9.1 d) v )(Heat shock - Sheath ) |
- |
0 |
|
- |
| 9.1 d) vi )(Shrinkage - insulation ) |
- |
0 |
|
- |
| 9.1 d) vi )(Shrinkage : Crack observed - insulation ) |
- |
0 |
|
- |
| 9.1 d) vi )(Shrinkage - Sheath ) |
- |
0 |
|
- |
| 9.1 d) vi )(Shrinkage: Crack observed - Sheath ) |
- |
0 |
|
- |
| 10.2(Voltage test ) |
- |
0 |
|
- |
| 9.1 f)(Insulation resistance test: Volume resistivity ) |
- |
0 |
|
- |
| 9.1 f)(Insulation resistance test : IR constant) |
- |
0 |
|
- |
| 10.4(Flammability Test ) |
- |
0 |
|
- |
| 11.1(Manufacturer’s Identification) |
- |
0 |
|
- |
| 11.2(Cable Code) |
- |
0 |
|
- |
| 12.1(packing ) |
- |
0 |
|
- |
| 12.2(Marking ) |
- |
0 |
|
- |
| 12.2.1(Standard marks ) |
- |
0 |
|
- |
|
- |
- Included w.e.f. 17.11.2023 |
| 7728 |
Alpha Test House Private Limited, Delhi
| 8131026
| IS 14255 (1995) |
Aertal bunched cables - For working voltages up to and including 1100 Volts - Specification |
- |
9000.00 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4.1(Phase/Street Lighting conductor) |
- |
50 |
|
- |
| 4.2(Messenger (Neutral Conductor or Otherwise)) |
- |
50 |
|
- |
| 5.1(Insulation) |
- |
50 |
|
- |
| 6.1(Flexibility class) |
- |
50 |
|
- |
| 6.2(Compactness) |
- |
50 |
|
- |
| 6.2(No of strands) |
- |
50 |
|
- |
| 6.2(Surface) |
- |
50 |
|
- |
| 6.3(Protective barrier) |
- |
50 |
|
- |
| 6.4(size of street lighting conductor) |
- |
50 |
|
- |
| 6.5(Size of messenger conductor ) |
- |
50 |
|
- |
| 6.6(Joints in messenger conductor ) |
- |
50 |
|
- |
| 6.6(Direction of outer layer) |
- |
50 |
|
- |
| 7.1(Insulation) |
- |
50 |
|
- |
| 7.2( Thickness of insulation) |
- |
250 |
|
- |
| 7.3(Tolerance on thickness of insulation ) |
- |
250 |
|
- |
| 7.4(Aplication of the insulation ) |
- |
50 |
|
- |
| 7.5(Colour of the insulation ) |
- |
50 |
|
- |
| 8.1(Core identification) |
- |
50 |
|
- |
| 8.2(Core identification) |
- |
50 |
|
- |
| 8.3(Identification by other means) |
- |
50 |
|
- |
| 9.1(Assembly (Laying up)) |
- |
50 |
|
- |
| 9.2(Assembly (Laying up)) |
- |
50 |
|
- |
| 9.3(Direction of lay) |
- |
50 |
|
- |
| 10.1 a) i)(Tests on phase/street light conductor: tensile test - Test method IS10810:Part 2) |
- |
500 |
|
- |
| 10.1 a) ii)(Wrapping test - 10810: Part 3) |
- |
250 |
|
- |
| 10.1 a) iii)(Resistance test - IS10810: Part 5) |
- |
1000 |
|
- |
| 10.1 b) i)(Test on messenger conductor: Breaking load - IS 10810: Part 2) |
- |
1000 |
|
- |
| 10.1 b) ii)(Test on messenger conductor: Elongation test - Cl 11.3) |
- |
500 |
|
- |
| 10.1 b) iii)(Test on messenger conductor: Resistance test - IS 10810: Part 5) |
- |
1000 |
|
- |
| 10.1 c) i)(Physical tests for XLPE Insulation:
Tensile strength - IS 10810: Part 7) |
- |
500 |
|
- |
| 10.1 c) i)(Physical tests for XLPE Insulation:
elongation at break - IS 10810: part 7) |
- |
500 |
|
- |
| 10.1 c) ii)(Ageing in air oven : Tensile strength variation - IS 10810:Part 11) |
- |
500 |
|
- |
| 10.1 c) ii)(Ageing in air oven : Elongation variation- IS 10810: Part 11) |
- |
500 |
|
- |
| 10.1 c) iii)(Hot set test: Elongation under load - IS 10810: Part 30) |
- |
250 |
|
- |
| 10.1 c) iii)(Hot set test: Permanent elongation (set) after cooling - IS 10810: Part 30) |
- |
250 |
|
- |
| 10.1 c) iv)(Shrinkage test : Shrinkage - 10810:Part 12) |
- |
200 |
|
- |
| 10.1 c) iv)(Shrinkage test : Crack Observed - 10810:Part 12) |
- |
200 |
|
- |
| 10.1 c) v)(Water ahsorption (Gravimetric) - IS 10810: Part 33 ) |
- |
1500 |
|
- |
| 10.1 d) i)(Physical test for PE insulation:
Tensile strength - IS 10810: Part 7 ) |
- |
250 |
|
- |
| 10.1 d) i)(Physical test for PE insulation: elongation at break - IS 10810: Part 7) |
- |
250 |
|
- |
| 10.1 d) ii)(Melt flow index- IS 10810: Part 23) |
- |
500 |
|
- |
| 10.1 d) iv)(Vicat softening point -IS 10810: Part 22) |
- |
500 |
|
- |
| 10.1 d) v)(Environmental stress cracking -IS 10810:Part29) |
- |
500 |
|
- |
| 10.1 f)(Insulation resistance (Volume resistivity) test a) volume resistivity at 27°C - IS 10810: Part 43) |
- |
250 |
|
- |
| 10.1 f)(Insulation resistance (Volume resistivity) test b) volume resistivity at 70°C - IS 10810: Part 43) |
- |
250 |
|
- |
| 10.1 g)(High voltage test - IS10810:Part 45) |
- |
500 |
|
- |
| 11.4(Bending Test on the Completed Cable ( Optional) ) |
- |
2000 |
|
- |
| 11.4(Bending Test on the Completed Cable ( Optional)) |
- |
2000 |
|
- |
| 4.1(Phase/Street Lighting conductor) |
- |
0 |
|
- |
| 4.2(Messenger (Neutral Conductor or Otherwise)) |
- |
0 |
|
- |
| 5.1(Insulation) |
- |
0 |
|
- |
| 6.1(Flexibility class) |
- |
0 |
|
- |
| 6.2(Compactness) |
- |
0 |
|
- |
| 6.2(No of strands) |
- |
0 |
|
- |
| 6.2(Surface) |
- |
0 |
|
- |
| 6.3(Protective barrier) |
- |
0 |
|
- |
| 6.4(size of street lighting conductor) |
- |
0 |
|
- |
| 6.5(Size of messenger conductor ) |
- |
0 |
|
- |
| 6.6(Joints in messenger conductor ) |
- |
0 |
|
- |
| 6.6(Direction of outer layer) |
- |
0 |
|
- |
| 7.1(Insulation) |
- |
0 |
|
- |
| 7.2( Thickness of insulation) |
- |
0 |
|
- |
| 7.3(Tolerance on thickness of insulation ) |
- |
0 |
|
- |
| 7.4(Aplication of the insulation ) |
- |
0 |
|
- |
| 7.5(Colour of the insulation ) |
- |
0 |
|
- |
| 8.1(Core identification) |
- |
0 |
|
- |
| 8.2(Core identification) |
- |
0 |
|
- |
| 8.3(Identification by other means) |
- |
0 |
|
- |
| 9.1(Assembly (Laying up)) |
- |
0 |
|
- |
| 9.2(Assembly (Laying up)) |
- |
0 |
|
- |
| 9.3(Direction of lay) |
- |
0 |
|
- |
| 10.1 a) i)(Tests on phase/street light conductor: tensile test - Test method IS10810:Part 2) |
- |
0 |
|
- |
| 10.1 a) ii)(Wrapping test - 10810: Part 3) |
- |
0 |
|
- |
| 10.1 a) iii)(Resistance test - IS10810: Part 5) |
- |
0 |
|
- |
| 10.1 b) i)(Test on messenger conductor: Breaking load - IS 10810: Part 2) |
- |
0 |
|
- |
| 10.1 b) ii)(Test on messenger conductor: Elongation test - Cl 11.3) |
- |
0 |
|
- |
| 10.1 b) iii)(Test on messenger conductor: Resistance test - IS 10810: Part 5) |
- |
0 |
|
- |
| 10.1 c) i)(Physical tests for XLPE Insulation:
Tensile strength - IS 10810: Part 7) |
- |
0 |
|
- |
| 10.1 c) i)(Physical tests for XLPE Insulation:
elongation at break - IS 10810: part 7) |
- |
0 |
|
- |
| 10.1 c) ii)(Ageing in air oven : Tensile strength variation - IS 10810:Part 11) |
- |
0 |
|
- |
| 10.1 c) ii)(Ageing in air oven : Elongation variation- IS 10810: Part 11) |
- |
0 |
|
- |
| 10.1 c) iii)(Hot set test: Elongation under load - IS 10810: Part 30) |
- |
0 |
|
- |
| 10.1 c) iii)(Hot set test: Permanent elongation (set) after cooling - IS 10810: Part 30) |
- |
0 |
|
- |
| 10.1 c) iv)(Shrinkage test : Shrinkage - 10810:Part 12) |
- |
0 |
|
- |
| 10.1 c) iv)(Shrinkage test : Crack Observed - 10810:Part 12) |
- |
0 |
|
- |
| 10.1 c) v)(Water ahsorption (Gravimetric) - IS 10810: Part 33 ) |
- |
0 |
|
- |
| 10.1 d) i)(Physical test for PE insulation:
Tensile strength - IS 10810: Part 7 ) |
- |
0 |
|
- |
| 10.1 d) i)(Physical test for PE insulation: elongation at break - IS 10810: Part 7) |
- |
0 |
|
- |
| 10.1 d) ii)(Melt flow index- IS 10810: Part 23) |
- |
0 |
|
- |
| 10.1 d) iv)(Vicat softening point -IS 10810: Part 22) |
- |
0 |
|
- |
| 10.1 d) v)(Environmental stress cracking -IS 10810:Part29) |
- |
0 |
|
- |
| 10.1 f)(Insulation resistance (Volume resistivity) test a) volume resistivity at 27°C - IS 10810: Part 43) |
- |
0 |
|
- |
| 10.1 f)(Insulation resistance (Volume resistivity) test b) volume resistivity at 70°C - IS 10810: Part 43) |
- |
0 |
|
- |
| 10.1 g)(High voltage test - IS10810:Part 45) |
- |
0 |
|
- |
| 11.4(Bending Test on the Completed Cable ( Optional) ) |
- |
0 |
|
- |
| 11.4(Bending Test on the Completed Cable ( Optional)) |
- |
0 |
|
- |
| 10.1 d) iii)(Carbon Black Content) |
- |
0 |
|
- |
|
- |
- Included w.e.f. 17.11.2023 |
| 7729 |
Alpha Test House Private Limited, Delhi
| 8131026
| IS 8784 (1987) |
Specification for thermocouple compensating cables (Second Revision) |
- |
20000.00 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 3.1(Type of thermocouple) |
- |
50 |
|
- |
| 4.1(Conductor) |
- |
50 |
|
- |
| 5(INSULATION AND SHEATH) |
- |
50 |
|
- |
| 6(ARMOURING) |
- |
4550 |
|
- |
| 7(SHIELDING) |
- |
50 |
|
- |
| 8.1(NOISE REDUCTION: Drain Wire) |
- |
50 |
|
- |
| 8.2(NOISE REDUCTION) |
- |
50 |
|
- |
| 9.1(DIMENSION : Single Wire) |
- |
50 |
|
- |
| 9.1.1(DIMENSION : Single Wire (Tolerances)) |
- |
50 |
|
- |
| 9.1.2(DIMENSION : Single Wire (Ovality)) |
- |
50 |
|
- |
| 9.2.1(Thickness of Insulation ) |
- |
750 |
|
- |
| 9.2.2(Thickness of Sheath ) |
- |
750 |
|
- |
| 9.3(Dimension of cable ) |
- |
750 |
|
- |
| 10.1(Colour Code ) |
- |
50 |
|
- |
| 11.1(ENVIRONMENTS FOR USE OF DIFFERENT THERMOCOUPLE
COMPENSATING CABLES) |
- |
50 |
|
- |
| 12.1(INFORMATION TO BE SUPPLIED BY THE MANUFACTURER) |
- |
50 |
|
- |
| 13.1(PACKING AND MARKING) |
- |
50 |
|
- |
| 13.2(PACKING AND MARKING) |
- |
50 |
|
- |
| 13.2.1(Standard Mark) |
- |
50 |
|
- |
| 14.2(Thermal emf Test ) |
- |
7000 |
|
- |
| 14.3(Resistance Test) |
- |
2000 |
|
- |
| 14.4.1( Thickness of Insulation) |
- |
750 |
|
- |
| 14.4.2.1( Thickness of Sheath : Round ) |
- |
750 |
|
- |
| 14.4.2.2( Thickness of Sheath : Oval ) |
- |
750 |
|
- |
| 14.5(Insulation Resistance Test :Volume resistivity ( Before High Voltage test )) |
- |
750 |
|
- |
| 15.5(Insulation Resistance Test :Insulation resistance constant ( Before High Voltage test )) |
- |
750 |
|
- |
| 14.5(Insulation Resistance Test: Volume resistivity ( After High Voltage test )) |
- |
750 |
|
- |
| 15.5(Insulation Resistance Test: Insulation Resisatnce constant ( After High Voltage test )) |
- |
750 |
|
- |
| 14.6(Drain Wire Continuity Test ) |
- |
500 |
|
- |
| 14.7(H.V. Test ) |
- |
1500 |
|
- |
| 14.8(Heat Shock Test) |
- |
800 |
|
- |
| 3.1(Type of thermocouple) |
- |
0 |
|
- |
| 4.1(Conductor) |
- |
0 |
|
- |
| 5(INSULATION AND SHEATH) |
- |
0 |
|
- |
| 6(ARMOURING) |
- |
0 |
|
- |
| 7(SHIELDING) |
- |
0 |
|
- |
| 8.1(NOISE REDUCTION: Drain Wire) |
- |
0 |
|
- |
| 8.2(NOISE REDUCTION) |
- |
0 |
|
- |
| 9.1(DIMENSION : Single Wire) |
- |
0 |
|
- |
| 9.1.1(DIMENSION : Single Wire (Tolerances)) |
- |
0 |
|
- |
| 9.1.2(DIMENSION : Single Wire (Ovality)) |
- |
0 |
|
- |
| 9.2.1(Thickness of Insulation ) |
- |
0 |
|
- |
| 9.2.2(Thickness of Sheath ) |
- |
0 |
|
- |
| 9.3(Dimension of cable ) |
- |
0 |
|
- |
| 10.1(Colour Code ) |
- |
0 |
|
- |
| 11.1(ENVIRONMENTS FOR USE OF DIFFERENT THERMOCOUPLE
COMPENSATING CABLES) |
- |
0 |
|
- |
| 12.1(INFORMATION TO BE SUPPLIED BY THE MANUFACTURER) |
- |
0 |
|
- |
| 13.1(PACKING AND MARKING) |
- |
0 |
|
- |
| 13.2(PACKING AND MARKING) |
- |
0 |
|
- |
| 13.2.1(Standard Mark) |
- |
0 |
|
- |
| 14.2(Thermal emf Test ) |
- |
0 |
|
- |
| 14.3(Resistance Test) |
- |
0 |
|
- |
| 14.4.1( Thickness of Insulation) |
- |
0 |
|
- |
| 14.4.2.1( Thickness of Sheath : Round ) |
- |
0 |
|
- |
| 14.4.2.2( Thickness of Sheath : Oval ) |
- |
0 |
|
- |
| 14.5(Insulation Resistance Test :Volume resistivity ( Before High Voltage test )) |
- |
0 |
|
- |
| 15.5(Insulation Resistance Test :Insulation resistance constant ( Before High Voltage test )) |
- |
0 |
|
- |
| 14.5(Insulation Resistance Test: Volume resistivity ( After High Voltage test )) |
- |
0 |
|
- |
| 15.5(Insulation Resistance Test: Insulation Resisatnce constant ( After High Voltage test )) |
- |
0 |
|
- |
| 14.6(Drain Wire Continuity Test ) |
- |
0 |
|
- |
| 14.7(H.V. Test ) |
- |
0 |
|
- |
| 14.8(Heat Shock Test) |
- |
0 |
|
- |
| 14.1.1, f)(Test for armour wires) |
- |
0 |
|
- |
|
- |
- Included w.e.f. 17.11.2023 |
| 7730 |
Alpha Test House Private Limited, Delhi
| 8131026
| IS 17048 (2018) |
Halogen free flame retardant (HFFR) cables for working voltages up to and including 1 100 Volts - Specification |
- |
195000.00 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4.1.1 a) (Conductor : Material ) |
- |
100 |
|
- |
| 4.1.1 b) (Material : Seperator tape ) |
- |
100 |
|
- |
| 4.1.1 d) , 11.1, 12.1, 13.1,14.1(Class of conductor ) |
- |
100 |
|
- |
| 4.1.1 e) (Shape of conductor ) |
- |
100 |
|
- |
| 4.1.1 f) (Nominal size of conductor ) |
- |
100 |
|
- |
| 4.2.1, 11.2, 12.2, 13.2, 14.2(Insulation : Material ) |
- |
100 |
|
- |
| 4.2.2, 11.2, 12.2, 13.2, 14.2(Insulation : Application ) |
- |
100 |
|
- |
| 4.2.3,11.2, 12.2, 13.2(Thickness of insulation - Avearge : IS 10810 ( Part 6 )) |
- |
200 |
|
- |
| 4.2.3, 11.2, 12.2, 13.2, 14.2(Thickness of insulation - miniumum : IS 10810 ( Part 6 )) |
- |
500 |
|
- |
| 4.2.4(Insulation : Tensile stregth ( Before ageing)-IS 10810 (Part 7) ) |
- |
2500 |
|
- |
| 4.2.4(Insulation : Elongation ( Before ageing) -IS 10810 (Part 7)) |
- |
2500 |
|
- |
| 4.2.4(Insulation : Tensile stregth ( After ageing) - IS 10810 (Part 7) ) |
- |
2500 |
|
- |
| 4.2.5(Insulation : Tensile stregth variation ( After ageing) - IS 10810 (Part 7) ) |
- |
2500 |
|
- |
| 4.2.4(Insulation : Elongation (after ageing) - IS 10810 (Part 7) ) |
- |
2500 |
|
- |
| 4.2.5(Insulation : Elongation variation (after ageing) - IS 10810 (Part 7) ) |
- |
2500 |
|
- |
| 4.3(Fillers) |
- |
1000 |
|
- |
| 4.4(Binder Tape) |
- |
1000 |
|
- |
| 4.5.1,13.4, 14.4(Sheath : Compound ) |
- |
500 |
|
- |
| 4.5.2, 13.4, 14.4(Sheath : Application) |
- |
500 |
|
- |
| 4.5.3,13.4, 14.4(Thickness of sheath - Average : IS 10810 (Part 6)) |
- |
500 |
|
- |
| 4.5.3,13.4, 14.4(Thickness of sheath - Minimum : IS 10810 (Part 6)) |
- |
500 |
|
- |
| 4.5.4, 13.4(Sheath : Tensile stregth ( Before ageing)-IS 10810 (Part 7) ) |
- |
0 |
|
- |
| 4.5.4,13.4(Sheath : Elongation ( Before ageing) -IS 10810 (Part 7)) |
- |
0 |
|
- |
| 4.5.4, 13.4, 14.4(Sheath : Tensile stregth ( After ageing) - IS 10810 (Part 7) ) |
- |
0 |
|
- |
| 4.5.5, 13.4, 14.4(Sheath : Tensile stregth variation ( After ageing) - IS 10810 (Part 7) ) |
- |
0 |
|
- |
| 4.5.4, 13.4, 14.4(Sheath : Elongation (after ageing) - IS 10810 (Part 7) ) |
- |
0 |
|
- |
| 4.5.5, 13.4,14.4(Sheath : Elongation variation (after ageing) - IS 10810 (Part 7) ) |
- |
0 |
|
- |
| 4.5.5, 11.3, 12.3, 13.6, 14.6(Overall Dimensions) |
- |
500 |
|
- |
| 4.5.5.1, 11.3, 12.3,13.5, 14.5(Ovality) |
- |
1000 |
|
- |
| 4.5.6, 13.4(Colour of Sheath) |
- |
1000 |
|
- |
| 5.1(High Voltage Test (at Room Temperature)) |
- |
5000 |
|
- |
| 5.3(Flammability Test- IS 10810 (Part 53).) |
- |
5000 |
|
- |
| 5.4(Oxygen Index Test- IS 10810 (Part 58)) |
- |
5000 |
|
- |
| 5.5(Temperature Index-IS 10810 (Part 64).) |
- |
5000 |
|
- |
| 5.6(Smoke Density-IS 10810 (Part 63).) |
- |
15000 |
|
- |
| 5.7(Assessment of Halogen- Table 1 of Annex D) |
- |
40000 |
|
- |
| 5.1(Persulphate Test- IS 10810 (Part 4).) |
- |
3000 |
|
- |
| 5.11(Flame Retardant Test- IS 10810 (Part 61),) |
- |
5000 |
|
- |
| 5.12(Hot Set Test- IS 10810 (Part 30).) |
- |
5000 |
|
- |
| 5.12(Permanent Set - IS 10810 (Part 30).) |
- |
5000 |
|
- |
| 5.13(Water Immersion Test (Effect of Water on Sheath) : Tensile strength -IS 10810 (Part 7).) |
- |
4000 |
|
- |
| 5.13(Water Immersion Test (Effect of Water on Sheath) : Elogation -IS 10810 (Part 7).) |
- |
4000 |
|
- |
| 5.14(Ozone Resistance Test -IS 10810 (Part 13 )) |
- |
15000 |
|
- |
| 5.15(Cold Bend Test-IS 10810 (Part 20).) |
- |
5000 |
|
- |
| 5.16(Cold Impact Test- IS 10810 (Part 21).) |
- |
5000 |
|
- |
| 6.1, Table 1(CORE IDENTIFICATION) |
- |
500 |
|
- |
| 6.2.1(Preferred Arrangement of Marking) |
- |
250 |
|
- |
| 6.2.2(Durability) |
- |
250 |
|
- |
| 7.0(CABLE CODE) |
- |
1000 |
|
- |
| 9.0( IDENTIFICATION) |
- |
1000 |
|
- |
| 10.1(Packing ) |
- |
100 |
|
- |
| 10.2(marking) |
- |
100 |
|
- |
| 10.2.1(Standards marking) |
- |
100 |
|
- |
| 13.3, 14.3(assembly of cores ) |
- |
1000 |
|
- |
| 6.1(General Requirements) |
- |
100 |
|
- |
| 6.1.1(Colour Combination Green Yellow) |
- |
100 |
|
- |
| 12.1(Conductor) |
- |
1000 |
|
- |
| 12.2, Table 4(insulation) |
- |
500 |
|
- |
| 4.3.1 (e)(Fluorine content test (Fillers)) |
- |
0 |
|
- |
| 4.3.1 (d)(Presence of fluorine test (Fillers)) |
- |
0 |
|
- |
| 4.3.1 (c)(Conductivity test (Fillers)) |
- |
0 |
|
- |
| 4.3.1 (b)(pH test (Fillers)) |
- |
0 |
|
- |
| 4.3.1 (a)(HCl test (Fillers)) |
- |
0 |
|
- |
| 5.7 (a)(HCl test (Assessment of halogen test)) |
- |
0 |
|
- |
| 5.7 (d)(Presence of fluorine test (Assessment of halogen test)) |
- |
0 |
|
- |
| 5.7 (e)(Fluorine content test (Assessment of halogen test)) |
- |
0 |
|
- |
| Table 2 ,( Clause 11.4, 12.4, 13.7 14.7 and 15.7 )(Insulation Resistance) |
- |
5000 |
|
- |
| "Table 2 ( Clause 11.4, 12.4, 13.7 14.7 and 15.7 )"(Conductor Resistance) |
- |
6000 |
|
- |
| Table 2 , Clause .5.13(Water immersion test (Effect of water on sheath) - TS Variation of Sheath) |
- |
4000 |
|
- |
| Table 2 , Clause 5.13(Water immersion test (Effect of water on sheath) - Elongation Variation of Sheath) |
- |
4000 |
|
- |
| "Table 2 ( Clause 11.4, 12.4, 13.7 14.7 and 15.7 )"(Hot Deformation) |
- |
5000 |
|
- |
| Table 2, III.a.ii(Annealing test (for Cu,
before stranding)) |
- |
2500 |
|
- |
| Table 2, II.a, b(Wrapping test before
stranding (for Al)) |
- |
1000 |
|
- |
| 6.1, Table 1(CORE IDENTIFICATION) |
- |
0 |
|
- |
| 6.1(General Requirements) |
- |
0 |
|
- |
| 6.1.1(Colour Combination Green Yellow) |
- |
0 |
|
- |
| 12.1(Conductor) |
- |
0 |
|
- |
| 12.2, Table 4(insulation) |
- |
0 |
|
- |
| 4.3.1 (e)(Fluorine content test (Fillers)) |
- |
0 |
|
- |
| 4.3.1 (d)(Presence of fluorine test (Fillers)) |
- |
0 |
|
- |
| 4.3.1 (c)(Conductivity test (Fillers)) |
- |
0 |
|
- |
| 4.3.1 (b)(pH test (Fillers)) |
- |
0 |
|
- |
| 4.3.1 (a)(HCl test (Fillers)) |
- |
0 |
|
- |
| 5.7 (a)(HCl test (Assessment of halogen test)) |
- |
0 |
|
- |
| 5.7 (d)(Presence of fluorine test (Assessment of halogen test)) |
- |
0 |
|
- |
| 5.7 (e)(Fluorine content test (Assessment of halogen test)) |
- |
0 |
|
- |
| Table 2 ,( Clause 11.4, 12.4, 13.7 14.7 and 15.7 )(Insulation Resistance) |
- |
0 |
|
- |
| "Table 2 ( Clause 11.4, 12.4, 13.7 14.7 and 15.7 )"(Conductor Resistance) |
- |
0 |
|
- |
| Table 2 , Clause .5.13(Water immersion test (Effect of water on sheath) - TS Variation of Sheath) |
- |
0 |
|
- |
| Table 2 , Clause 5.13(Water immersion test (Effect of water on sheath) - Elongation Variation of Sheath) |
- |
0 |
|
- |
| "Table 2 ( Clause 11.4, 12.4, 13.7 14.7 and 15.7 )"(Hot Deformation) |
- |
0 |
|
- |
| Table 2, III.a.ii(Annealing test (for Cu,
before stranding)) |
- |
0 |
|
- |
| Table 2, II.a, b(Wrapping test before
stranding (for Al)) |
- |
0 |
|
- |
|
- |
- Included w.e.f. 17.11.2023. Exclusion: Cl.5.2 (Spark Test (Routine test)), Table-4 (Copper Purity test) |
| 7731 |
Alpha Test House Private Limited, Delhi
| 8131026
| IS 2593 (1984) |
Flexible Cables for Miners' Cap-lamps |
- |
35000.00 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 3.1(CONDUCTOR) |
- |
50 |
|
- |
| 3.1.1(Per sulphate test ) |
- |
2000 |
|
- |
| 3.1.2(Resistance test ) |
- |
2000 |
|
- |
| 4.1(INSULATION) |
- |
50 |
|
- |
| 6.1(SHEATH) |
- |
50 |
|
- |
| 7.1(Construction : Conductor ) |
- |
50 |
|
- |
| 8.1(Thickness of Insulation - Average ) |
- |
250 |
|
- |
| 8.1(Thickness of Insulation - minimum) |
- |
250 |
|
- |
| 9.1(IDENTIFICATION OF CORES) |
- |
50 |
|
- |
| 10.1(LAYING UP) |
- |
50 |
|
- |
| 11.1(SHEATH : Application ) |
- |
50 |
|
- |
| 11.2(Thickness of Sheath -average ) |
- |
250 |
|
- |
| 12.2(Thickness of Sheath - Minimum) |
- |
250 |
|
- |
| 11.3(Coulor of sheath ) |
- |
50 |
|
- |
| 12.1(OVERALL DIAMETER) |
- |
500 |
|
- |
| 13.1 b)(Annealing test) |
- |
500 |
|
- |
| 13.1 e) 1)(Physical tests for insulation: Tensile strength ) |
- |
750 |
|
- |
| 13.1 e) 1)(Physical tests for insulation: elongation at break ) |
- |
750 |
|
- |
| 13.1 e) 1)(Physical tests for Sheath : Tensile strength ) |
- |
750 |
|
- |
| 13.1 e) 1)(Physical tests for Sheath: elongation at break ) |
- |
750 |
|
- |
| 13.1 e) 2)(Ageing in air oven ( for insulation ) : Tensile Strength ) |
- |
750 |
|
- |
| 13.1 e) 2)(Ageing in air oven ( for insulation ) : Tensile Strength variation ) |
- |
750 |
|
- |
| 13.1 e) 2)(Ageing in air oven ( for insulation ) : elongation variation at break) |
- |
750 |
|
- |
| 13.1 e) 2)(Ageing in air oven ( for insulation ) : elongation variation at break) |
- |
750 |
|
- |
| 13.1 e) 3)(Ageing in oxygen bomb ( for insulation ) : Tensile Strength variation ) |
- |
1750 |
|
- |
| 13.1 e) 3)(Ageing in oxygen bomb ( for insulation ) : elongation variation at break) |
- |
1750 |
|
- |
| 13.1 e) 3)(Ageing in air bomb ( for sheath ) : Tensile Strength variation ) |
- |
1750 |
|
- |
| 13.1 e) 3)(Ageing in air bomb ( for sheath ) : elongation variation at break) |
- |
1750 |
|
- |
| 13.1 e) 4)(Oil resistance test ( for sheath ) : Tensile strength variation ) |
- |
1250 |
|
- |
| 13.1 e) 4)(Oil resistance test ( for sheath ) : Elongation variation ) |
- |
1250 |
|
- |
| 14.1(Voltage test) |
- |
3000 |
|
- |
| 14.2(Flammability test) |
- |
1000 |
|
- |
| 14.3.1(Centre Strain Cord : Breaking Load ) |
- |
50 |
|
- |
| 14.3.2(Centre Strain Cord : Determination of Copper and Manganese Content) |
- |
50 |
|
- |
| 14.4(Checking of overall diameter of cable) |
- |
0 |
|
- |
| 14.5(Resistance of sheath to fatty acids : Weigth Increase ) |
- |
750 |
|
- |
| 14.5(Resistance of sheath to fatty acids : Diameter Increase ) |
- |
750 |
|
- |
| 15.1(MANUFACTURER'S IDENTIFICATION) |
- |
50 |
|
- |
| 16.1(Packing ) |
- |
50 |
|
- |
| 16.2(Marking ) |
- |
50 |
|
- |
| 16.2.1(Standards Mark ) |
- |
50 |
|
- |
| 6.1(Resistance of Sheath to Fatty Acids - 14.5 - diameter increase) |
- |
0 |
|
- |
| 6.1(Resistance of Sheath to Fatty Acids - 14.5 - weight increase) |
- |
0 |
|
- |
| 5.1(Copper and Manganese Content - Cl 14.3.2) |
- |
50 |
|
- |
| 3.1.1(mass of copper - Cl 7.1 of IS 8130 read with Method B of IS 10810 (Part 4)) |
- |
0 |
|
- |
| 3.1(CONDUCTOR) |
- |
0 |
|
- |
| 3.1.1(Per sulphate test ) |
- |
0 |
|
- |
| 3.1.2(Resistance test ) |
- |
0 |
|
- |
| 4.1(INSULATION) |
- |
0 |
|
- |
| 6.1(SHEATH) |
- |
0 |
|
- |
| 7.1(Construction : Conductor ) |
- |
0 |
|
- |
| 8.1(Thickness of Insulation - Average ) |
- |
0 |
|
- |
| 8.1(Thickness of Insulation - minimum) |
- |
0 |
|
- |
| 9.1(IDENTIFICATION OF CORES) |
- |
0 |
|
- |
| 10.1(LAYING UP) |
- |
0 |
|
- |
| 11.1(SHEATH : Application ) |
- |
0 |
|
- |
| 11.2(Thickness of Sheath -average ) |
- |
0 |
|
- |
| 12.2(Thickness of Sheath - Minimum) |
- |
0 |
|
- |
| 11.3(Coulor of sheath ) |
- |
0 |
|
- |
| 12.1(OVERALL DIAMETER) |
- |
0 |
|
- |
| 13.1 b)(Annealing test) |
- |
0 |
|
- |
| 13.1 e) 1)(Physical tests for insulation: Tensile strength ) |
- |
0 |
|
- |
| 13.1 e) 1)(Physical tests for insulation: elongation at break ) |
- |
0 |
|
- |
| 13.1 e) 1)(Physical tests for Sheath : Tensile strength ) |
- |
0 |
|
- |
| 13.1 e) 1)(Physical tests for Sheath: elongation at break ) |
- |
0 |
|
- |
| 13.1 e) 2)(Ageing in air oven ( for insulation ) : Tensile Strength ) |
- |
0 |
|
- |
| 13.1 e) 2)(Ageing in air oven ( for insulation ) : Tensile Strength variation ) |
- |
0 |
|
- |
| 13.1 e) 2)(Ageing in air oven ( for insulation ) : elongation variation at break) |
- |
0 |
|
- |
| 13.1 e) 2)(Ageing in air oven ( for insulation ) : elongation variation at break) |
- |
0 |
|
- |
| 13.1 e) 3)(Ageing in oxygen bomb ( for insulation ) : Tensile Strength variation ) |
- |
0 |
|
- |
| 13.1 e) 3)(Ageing in oxygen bomb ( for insulation ) : elongation variation at break) |
- |
0 |
|
- |
| 13.1 e) 3)(Ageing in air bomb ( for sheath ) : Tensile Strength variation ) |
- |
0 |
|
- |
| 13.1 e) 3)(Ageing in air bomb ( for sheath ) : elongation variation at break) |
- |
0 |
|
- |
| 13.1 e) 4)(Oil resistance test ( for sheath ) : Tensile strength variation ) |
- |
0 |
|
- |
| 13.1 e) 4)(Oil resistance test ( for sheath ) : Elongation variation ) |
- |
0 |
|
- |
| 14.1(Voltage test) |
- |
0 |
|
- |
| 14.2(Flammability test) |
- |
0 |
|
- |
| 14.3.1(Centre Strain Cord : Breaking Load ) |
- |
0 |
|
- |
| 14.3.2(Centre Strain Cord : Determination of Copper and Manganese Content) |
- |
0 |
|
- |
| 14.4(Checking of overall diameter of cable) |
- |
0 |
|
- |
| 14.5(Resistance of sheath to fatty acids : Weigth Increase ) |
- |
0 |
|
- |
| 14.5(Resistance of sheath to fatty acids : Diameter Increase ) |
- |
0 |
|
- |
| 15.1(MANUFACTURER'S IDENTIFICATION) |
- |
0 |
|
- |
| 16.1(Packing ) |
- |
0 |
|
- |
| 16.2(Marking ) |
- |
0 |
|
- |
| 16.2.1(Standards Mark ) |
- |
0 |
|
- |
|
- |
- Included w.e.f. 17.11.2023. Exclusion: Cl.14.3.2 (Centre Strain Cord : Determination of Copper and Manganese Content) |
| 7732 |
Alpha Test House Private Limited, Delhi
| 8131026
| IS 2465 (1984) |
Specification for cables for motor vehicles (Second Revision) |
- |
15000.00 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 7.1(Insulation) |
- |
10 |
|
- |
| 7.3(Insulation) |
- |
10 |
|
- |
| 8(Core Identification) |
- |
20 |
|
- |
| 9(Laying up of cores) |
- |
20 |
|
- |
| 10.1.1(Sheathing ) |
- |
20 |
|
- |
| 10.2(Sheathing ) |
- |
20 |
|
- |
| 3 & 6(Flexibility class) |
- |
20 |
|
- |
| 3 & 6(Construction) |
- |
20 |
|
- |
| 3 & 6(Diameter of wire(mm)) |
- |
20 |
|
- |
| 3 & 6(Annealing test) |
- |
20 |
|
- |
| 3 & 6(Persulphate Test) |
- |
20 |
|
- |
| 3 & 6(Conductor resistance Test (ohm/km at 20Ëšc)) |
- |
20 |
|
- |
| 7.2, 10.3, 11(Dimensions & thickness ) |
- |
350 |
|
- |
| 7.2, 10.3, 11(Dimensions & thickness ) |
- |
0 |
|
- |
| 7.2, 10.3, 11(Overall Dimension (mm)) |
- |
0 |
|
- |
| 4.2 & 12.1(Without Ageing For Insulation
Tensile Strength (N/mm²)) |
- |
250 |
|
- |
| 4.2 & 12.1, (f), 1(elongation at break (N/mm²)) |
- |
250 |
|
- |
| 4.2 & 12.1, (f), 1(Tensile Strength at break (N/mm²)) |
- |
0 |
|
- |
| 4.2 & 12.1, (e), 1(elongation test at break) |
- |
0 |
|
- |
| 4.2 & 12.1, (e), 1(Tensile strength at break) |
- |
0 |
|
- |
| 4.2 & 12.1, (f), 2(Ageing in air oven) |
- |
750 |
|
- |
| 4.2 & 12.1, (f), 3(Ageing in oxygen bomb) |
- |
700 |
|
- |
| 4.2 & 12.1, (e), 2(After Ageing in air oven) |
- |
0 |
|
- |
| 4.2 & 12.1, (e), 3(Loss of mass test (mg/cm²) of Insulation) |
- |
750 |
|
- |
| 4.2 & 12.1, (e), 3(Loss of mass test (mg/cm²) of Sheath) |
- |
0 |
|
- |
| 4.2 & 12.1, (e), 4(Hot deformation test (%) of Insulation) |
- |
250 |
|
- |
| 4.2 & 12.1, (e), 4(Hot deformation test (%) of Sheath) |
- |
250 |
|
- |
| 4.2 & 12.1, (e), 5(Heat Shock Test of Insulation) |
- |
125 |
|
- |
| 4.2 & 12.1, (e), 5(Heat Shock Test of Sheath) |
- |
125 |
|
- |
| 4.2 & 12.1, (e), 6(Shrinkage Test (%) of Insulation) |
- |
100 |
|
- |
| 4.2 & 12.1, (e), 6(Shrinkage Test (%) of Sheath) |
- |
100 |
|
- |
| 14(High Voltage Test) |
- |
1500 |
|
- |
| 16.1(CAPACITANCE TEST FOR PVC INSULATION IGNITION CABLE) |
- |
1000 |
|
- |
| 17.1(OZONE RESISTANCE TEST FOR IGNITION CABLES) |
- |
1000 |
|
- |
| 18.1(EFFECT OF HEAT ON FLEXIBILITY FOR IGNITION CABLES) |
- |
1000 |
|
- |
| 19.1(EFFECT OF OIL ON IGNITION CABLES) |
- |
200 |
|
- |
| 19.2(EFFECT OF OIL ON IGNITION CABLES) |
- |
200 |
|
- |
| 20.3(EFFECT OF LUBRICATING OIL) |
- |
200 |
|
- |
| 20.3(EFFECT OF BRAKE FLUID) |
- |
200 |
|
- |
| 20.3(EFFECT OF DIESEL) |
- |
200 |
|
- |
| 20.3(Increase in average diameter %) |
- |
0 |
|
- |
| 20.3(Wrapping test) |
- |
0 |
|
- |
| 21.1(EFFECT OF COOLING ON FLEXIBILITY) |
- |
1000 |
|
- |
| 21.2(EFFECT OF COOLING ON FLEXIBILITY) |
- |
0 |
|
- |
| 21.2(EFFECT OF COOLING ON FLEXIBILITY) |
- |
0 |
|
- |
| 22.1(FLAMMABILITY TEST) |
- |
250 |
|
- |
| 22.1(FLAMMABILITY TEST) |
- |
0 |
|
- |
| 23.1(Manufacturer's Identification) |
- |
20 |
|
- |
| 23.1(Manufacturer's Identification) |
- |
0 |
|
- |
| 24.1(PACKING AND MARKING) |
- |
10 |
|
- |
| 24.2.1(PACKING AND MARKING) |
- |
10 |
|
- |
| 7.1(Insulation) |
- |
0 |
|
- |
| 7.3(Insulation) |
- |
0 |
|
- |
| 8(Core Identification) |
- |
0 |
|
- |
| 9(Laying up of cores) |
- |
0 |
|
- |
| 10.1.1(Sheathing ) |
- |
0 |
|
- |
| 10.2(Sheathing ) |
- |
0 |
|
- |
| 3 & 6(Flexibility class) |
- |
0 |
|
- |
| 3 & 6(Construction) |
- |
0 |
|
- |
| 3 & 6(Diameter of wire(mm)) |
- |
0 |
|
- |
| 3 & 6(Annealing test) |
- |
0 |
|
- |
| 3 & 6(Persulphate Test) |
- |
0 |
|
- |
| 3 & 6(Conductor resistance Test (ohm/km at 20Ëšc)) |
- |
0 |
|
- |
| 7.2, 10.3, 11(Dimensions & thickness ) |
- |
0 |
|
- |
| 7.2, 10.3, 11(Dimensions & thickness ) |
- |
0 |
|
- |
| 7.2, 10.3, 11(Overall Dimension (mm)) |
- |
0 |
|
- |
| 4.2 & 12.1(Without Ageing For Insulation
Tensile Strength (N/mm²)) |
- |
0 |
|
- |
| 4.2 & 12.1, (f), 1(elongation at break (N/mm²)) |
- |
0 |
|
- |
| 4.2 & 12.1, (f), 1(Tensile Strength at break (N/mm²)) |
- |
0 |
|
- |
| 4.2 & 12.1, (e), 1(elongation test at break) |
- |
0 |
|
- |
| 4.2 & 12.1, (e), 1(Tensile strength at break) |
- |
0 |
|
- |
| 4.2 & 12.1, (f), 2(Ageing in air oven) |
- |
0 |
|
- |
| 4.2 & 12.1, (f), 3(Ageing in oxygen bomb) |
- |
0 |
|
- |
| 4.2 & 12.1, (e), 2(After Ageing in air oven) |
- |
0 |
|
- |
| 4.2 & 12.1, (e), 3(Loss of mass test (mg/cm²) of Insulation) |
- |
0 |
|
- |
| 4.2 & 12.1, (e), 3(Loss of mass test (mg/cm²) of Sheath) |
- |
0 |
|
- |
| 4.2 & 12.1, (e), 4(Hot deformation test (%) of Insulation) |
- |
0 |
|
- |
| 4.2 & 12.1, (e), 4(Hot deformation test (%) of Sheath) |
- |
0 |
|
- |
| 4.2 & 12.1, (e), 5(Heat Shock Test of Insulation) |
- |
0 |
|
- |
| 4.2 & 12.1, (e), 5(Heat Shock Test of Sheath) |
- |
0 |
|
- |
| 4.2 & 12.1, (e), 6(Shrinkage Test (%) of Insulation) |
- |
0 |
|
- |
| 4.2 & 12.1, (e), 6(Shrinkage Test (%) of Sheath) |
- |
0 |
|
- |
| 14(High Voltage Test) |
- |
0 |
|
- |
| 16.1(CAPACITANCE TEST FOR PVC INSULATION IGNITION CABLE) |
- |
0 |
|
- |
| 17.1(OZONE RESISTANCE TEST FOR IGNITION CABLES) |
- |
0 |
|
- |
| 18.1(EFFECT OF HEAT ON FLEXIBILITY FOR IGNITION CABLES) |
- |
0 |
|
- |
| 19.1(EFFECT OF OIL ON IGNITION CABLES) |
- |
0 |
|
- |
| 19.2(EFFECT OF OIL ON IGNITION CABLES) |
- |
0 |
|
- |
| 20.3(EFFECT OF LUBRICATING OIL) |
- |
0 |
|
- |
| 20.3(EFFECT OF BRAKE FLUID) |
- |
0 |
|
- |
| 20.3(EFFECT OF DIESEL) |
- |
0 |
|
- |
| 20.3(Increase in average diameter %) |
- |
0 |
|
- |
| 20.3(Wrapping test) |
- |
0 |
|
- |
| 21.1(EFFECT OF COOLING ON FLEXIBILITY) |
- |
0 |
|
- |
| 21.2(EFFECT OF COOLING ON FLEXIBILITY) |
- |
0 |
|
- |
| 21.2(EFFECT OF COOLING ON FLEXIBILITY) |
- |
0 |
|
- |
| 22.1(FLAMMABILITY TEST) |
- |
0 |
|
- |
| 22.1(FLAMMABILITY TEST) |
- |
0 |
|
- |
| 23.1(Manufacturer's Identification) |
- |
0 |
|
- |
| 23.1(Manufacturer's Identification) |
- |
0 |
|
- |
| 24.1(PACKING AND MARKING) |
- |
0 |
|
- |
| 24.2.1(PACKING AND MARKING) |
- |
0 |
|
- |
|
- |
- Included w.e.f. 17.11.2023. Exclusion: Cl.15 (SPARK TEST FOR SINGLE CORE GENERAL WIRING CABLES) |
| 7733 |
Alpha Test House Private Limited, Delhi
| 8131026
| IS 398 : Part 4 (1994) |
Aluminium conductors for overhead transmission purposes: Part 4 aluminium alloy stranded conductors (Aluminium - Magnesium - Silicon Type) - Specification (Third Revision) |
- |
10000.00 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 6.1(Freedom from Defects) |
- |
100 |
|
- |
| 7.1 Table-1(Dimensional measurement of wires) |
- |
1200 |
|
- |
| 7.2.2 Table-2, Table-4(Calculated resistance of Stranded Conductor) |
- |
1300 |
|
- |
| 8.1(Joints in wires-Conductors Containing Seven Wires) |
- |
100 |
|
- |
| 8.2(Joints in wires-Conductors Containing More Than Seven Wires) |
- |
150 |
|
- |
| 9.1(Stranding) |
- |
100 |
|
- |
| 9.2 Table 3(Lay Ratio of stranded conductors) |
- |
350 |
|
- |
| 9.3(Direction of Lay) |
- |
350 |
|
- |
| 9.4(Multiple layers of wires) |
- |
0 |
|
- |
| 11(Packing and Marking) |
- |
0 |
|
- |
| 12.2 Table 1(Breaking Load Test- Before Stranding) |
- |
625 |
|
- |
| 12.2 Table 1(Breaking Load Test- After Stranding) |
- |
625 |
|
- |
| 12.3 Table 1(Elongation Test- Before Stranding) |
- |
625 |
|
- |
| 12.3 Table 1(Elongation Test- After Stranding) |
- |
625 |
|
- |
| 12.4 Table 1(Resistance of Aluminium wire) |
- |
2000 |
|
- |
| 9.2(Lay Ratio 24 wire layer) |
- |
700 |
|
- |
| 9.2(Lay Ratio 18 wire layer) |
- |
175 |
|
- |
| 9.2(Lay Ratio 12 wire layer) |
- |
700 |
|
- |
| 9.2(Lay Ratio 3/6 wire layer) |
- |
175 |
|
- |
| 6.1(Freedom from Defects) |
- |
0 |
|
- |
| 7.1 Table-1(Dimensional measurement of wires) |
- |
0 |
|
- |
| 7.2.2 Table-2, Table-4(Calculated resistance of Stranded Conductor) |
- |
0 |
|
- |
| 8.1(Joints in wires-Conductors Containing Seven Wires) |
- |
0 |
|
- |
| 8.2(Joints in wires-Conductors Containing More Than Seven Wires) |
- |
0 |
|
- |
| 9.1(Stranding) |
- |
0 |
|
- |
| 9.2 Table 3(Lay Ratio of stranded conductors) |
- |
0 |
|
- |
| 9.3(Direction of Lay) |
- |
0 |
|
- |
| 9.4(Multiple layers of wires) |
- |
0 |
|
- |
| 11(Packing and Marking) |
- |
0 |
|
- |
| 12.2 Table 1(Breaking Load Test- Before Stranding) |
- |
0 |
|
- |
| 12.2 Table 1(Breaking Load Test- After Stranding) |
- |
0 |
|
- |
| 12.3 Table 1(Elongation Test- Before Stranding) |
- |
0 |
|
- |
| 12.3 Table 1(Elongation Test- After Stranding) |
- |
0 |
|
- |
| 12.4 Table 1(Resistance of Aluminium wire) |
- |
0 |
|
- |
| 9.2(Lay Ratio 24 wire layer) |
- |
0 |
|
- |
| 9.2(Lay Ratio 18 wire layer) |
- |
0 |
|
- |
| 9.2(Lay Ratio 12 wire layer) |
- |
0 |
|
- |
| 9.2(Lay Ratio 3/6 wire layer) |
- |
0 |
|
- |
|
- |
- Included w.e.f. 17.11.2023 |
| 7734 |
Alpha Test House Private Limited, Delhi
| 8131026
| IS 398 : Part 2 (1996) |
Aluminium conductors for overhead transmission purposes - Specification: Part 2 aluminium conuuctors, galvanized steel - Reinforced (Third Revision) |
- |
10000.00 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 8.1.1 & 13.2 Table-1 (mech)(Diameter of Aluminium Wires Before Stranding) |
- |
250 |
|
- |
| 8.1.1 & 13.2 Table 2 (mech)(Diameter of Steel Wires Before Stranding) |
- |
250 |
|
- |
| 8.1.1 & 13.2 Table-1 (mech)(Diameter of Aluminium Wires After Stranding) |
- |
250 |
|
- |
| 8.1.1 & 13.2 Table 2 (mech)(Diameter of Steel Wires After Stranding) |
- |
250 |
|
- |
| 10 (elec)(Stranding) |
- |
100 |
|
- |
| 10 (elec)(Stranding) |
- |
0 |
|
- |
| 10 (elec)(Stranding) |
- |
0 |
|
- |
| 10 (mech)(Stranding) |
- |
0 |
|
- |
| 13.3 Table 1 (mech)(Breaking Load of Aluminium Wires Before Stranding) |
- |
250 |
|
- |
| 13.3 Table 2 (mech)(Breaking Load of Steel Wires Before Stranding) |
- |
250 |
|
- |
| 13.3 Table 1 (mech)(Breaking Load of Aluminium Wires After Stranding) |
- |
250 |
|
- |
| 13.3 Table 2 (mech)(Breaking Load of Steel Wires After Stranding) |
- |
250 |
|
- |
| 13.4.1 (mech)(Ductility by Torsion Test before stranding) |
- |
500 |
|
- |
| 13.4.1 (mech)(Ductility by Torsion Test before stranding) |
- |
0 |
|
- |
| 13.4.1 (mech)(Ductility by Torsion Test after stranding) |
- |
500 |
|
- |
| 13.4.1 (mech)(Ductility by Torsion Test after stranding) |
- |
0 |
|
- |
| 13.4.2 (elec)(Ductility by Elongation Test before stranding) |
- |
350 |
|
- |
| 13.4.2 (elec)(Ductility by Elongation Test after stranding) |
- |
350 |
|
- |
| 13.5.1 (mech)(Wrapping Test Aluminium Wires Before Stranding) |
- |
175 |
|
- |
| 13.5.1 (mech)(Wrapping Test Aluminium Wires After Stranding) |
- |
175 |
|
- |
| 13.5.2 (mech)(Wrapping Test Galvanized Steel Wires Before Stranding) |
- |
175 |
|
- |
| 13.5.2 (mech)(Wrapping Test Galvanized Steel Wires After Stranding) |
- |
175 |
|
- |
| 13.6 (elec)(Resistance test-Aluminium wire before Stranding) |
- |
750 |
|
- |
| 13.6 (elec)(Resistance test-Aluminium wire after stranding) |
- |
750 |
|
- |
| 13.7.2 (chem)(Mass of Zinc coating) |
- |
700 |
|
- |
| 13.7.2 (chem)(Uniformity of Zinc coating) |
- |
700 |
|
- |
| 13.8 Table-4 (mech)(Lay Ratio- Aluminium Wire Outermost Layer) |
- |
75 |
|
- |
| 13.8 Table-4 (mech)(Lay Ratio- Aluminium Wire Layer Immediately Beneath Outermost Layer) |
- |
75 |
|
- |
| 13.8 Table-4 (mech)(Lay Ratio- Aluminium Wire Innermost Layer of Conductors with 3 Aluminium Wire Layers) |
- |
75 |
|
- |
| 13.8 Table-4 (mech)(Lay Ratio- Steel Core (6 Wire Layer)) |
- |
75 |
|
- |
| 13.8 Table-4 (elec)(Lay Ratio- Steel Core (6 Wire Layer)) |
- |
75 |
|
- |
| 13.8 Table-4 (elec)(Lay Ratio- Steel Core (6 Wire Layer)) |
- |
75 |
|
- |
| 13.8 Table-4 (elec)(Lay Ratio- Aluminium Wire Innermost Layer of Conductors with 3 Aluminium Wire Layers) |
- |
75 |
|
- |
| 13.8 Table-4 (elec)(Lay Ratio- Aluminium Wire Layer Immediately Beneath Outermost Layer) |
- |
75 |
|
- |
| 13.7.2 (elec)(Uniformity of Zinc coating) |
- |
700 |
|
- |
| 13.7.2 (elec)(Mass of Zinc coating) |
- |
700 |
|
- |
| 13.5.2 (elec)(Wrapping Test Galvanized Steel Wires After Stranding) |
- |
600 |
|
- |
| 13.5.2 (elec)(Wrapping Test Galvanized Steel Wires Before Stranding) |
- |
0 |
|
- |
| 13.5.1 (elec)(Wrapping Test Aluminium Wires After Stranding) |
- |
0 |
|
- |
| 13.5.1 (elec)(Wrapping Test Aluminium Wires Before Stranding) |
- |
0 |
|
- |
| 13.4.1 (elec)(Ductility by Torsion Test after stranding) |
- |
0 |
|
- |
| 13.4.1 (elec)(Ductility by Torsion Test after stranding) |
- |
0 |
|
- |
| 13.4.1 (elec)(Ductility by Torsion Test before stranding) |
- |
0 |
|
- |
| 13.4.1 (elec)(Ductility by Torsion Test before stranding) |
- |
0 |
|
- |
| 13.3 Table 2 (elec)(Breaking Load of Steel Wires After Stranding) |
- |
0 |
|
- |
| 13.3 Table 1 (elec)(Breaking Load of Steel Wires After Stranding) |
- |
0 |
|
- |
| 13.3 Table 1 (elec)(Breaking Load of Aluminium Wires Before Stranding) |
- |
0 |
|
- |
| 10 (elec)(Stranding) |
- |
0 |
|
- |
| 8.1.1 & 13.2 Table 2 (elec)(Diameter of Steel Wires After Stranding) |
- |
0 |
|
- |
| 8.1.1 & 13.2 Table-1 (elec)(Diameter of Aluminium Wires After Stranding) |
- |
0 |
|
- |
| 8.1.1 & 13.2 Table 2 (elec)(Diameter of Steel Wires Before Stranding) |
- |
0 |
|
- |
| 8.1.1 & 13.2 Table-1 (elec)(Diameter of Aluminium Wires Before Stranding) |
- |
0 |
|
- |
| 8.1.1 & 13.2 Table-1 (mech)(Diameter of Aluminium Wires Before Stranding) |
- |
0 |
|
- |
| 8.1.1 & 13.2 Table 2 (mech)(Diameter of Steel Wires Before Stranding) |
- |
0 |
|
- |
| 8.1.1 & 13.2 Table-1 (mech)(Diameter of Aluminium Wires After Stranding) |
- |
0 |
|
- |
| 8.1.1 & 13.2 Table 2 (mech)(Diameter of Steel Wires After Stranding) |
- |
0 |
|
- |
| 10 (elec)(Stranding) |
- |
0 |
|
- |
| 10 (elec)(Stranding) |
- |
0 |
|
- |
| 10 (elec)(Stranding) |
- |
0 |
|
- |
| 10 (mech)(Stranding) |
- |
0 |
|
- |
| 13.3 Table 1 (mech)(Breaking Load of Aluminium Wires Before Stranding) |
- |
0 |
|
- |
| 13.3 Table 2 (mech)(Breaking Load of Steel Wires Before Stranding) |
- |
0 |
|
- |
| 13.3 Table 1 (mech)(Breaking Load of Aluminium Wires After Stranding) |
- |
0 |
|
- |
| 13.3 Table 2 (mech)(Breaking Load of Steel Wires After Stranding) |
- |
0 |
|
- |
| 13.4.1 (mech)(Ductility by Torsion Test before stranding) |
- |
0 |
|
- |
| 13.4.1 (mech)(Ductility by Torsion Test before stranding) |
- |
0 |
|
- |
| 13.4.1 (mech)(Ductility by Torsion Test after stranding) |
- |
0 |
|
- |
| 13.4.1 (mech)(Ductility by Torsion Test after stranding) |
- |
0 |
|
- |
| 13.4.2 (elec)(Ductility by Elongation Test before stranding) |
- |
0 |
|
- |
| 13.4.2 (elec)(Ductility by Elongation Test after stranding) |
- |
0 |
|
- |
| 13.5.1 (mech)(Wrapping Test Aluminium Wires Before Stranding) |
- |
0 |
|
- |
| 13.5.1 (mech)(Wrapping Test Aluminium Wires After Stranding) |
- |
0 |
|
- |
| 13.5.2 (mech)(Wrapping Test Galvanized Steel Wires Before Stranding) |
- |
0 |
|
- |
| 13.5.2 (mech)(Wrapping Test Galvanized Steel Wires After Stranding) |
- |
0 |
|
- |
| 13.6 (elec)(Resistance test-Aluminium wire before Stranding) |
- |
0 |
|
- |
| 13.6 (elec)(Resistance test-Aluminium wire after stranding) |
- |
0 |
|
- |
| 13.7.2 (chem)(Mass of Zinc coating) |
- |
0 |
|
- |
| 13.7.2 (chem)(Uniformity of Zinc coating) |
- |
0 |
|
- |
| 13.8 Table-4 (mech)(Lay Ratio- Aluminium Wire Outermost Layer) |
- |
0 |
|
- |
| 13.8 Table-4 (mech)(Lay Ratio- Aluminium Wire Layer Immediately Beneath Outermost Layer) |
- |
0 |
|
- |
| 13.8 Table-4 (mech)(Lay Ratio- Aluminium Wire Innermost Layer of Conductors with 3 Aluminium Wire Layers) |
- |
0 |
|
- |
| 13.8 Table-4 (mech)(Lay Ratio- Steel Core (6 Wire Layer)) |
- |
0 |
|
- |
| 13.8 Table-4 (elec)(Lay Ratio- Steel Core (6 Wire Layer)) |
- |
0 |
|
- |
| 13.8 Table-4 (elec)(Lay Ratio- Steel Core (6 Wire Layer)) |
- |
0 |
|
- |
| 13.8 Table-4 (elec)(Lay Ratio- Aluminium Wire Innermost Layer of Conductors with 3 Aluminium Wire Layers) |
- |
0 |
|
- |
| 13.8 Table-4 (elec)(Lay Ratio- Aluminium Wire Layer Immediately Beneath Outermost Layer) |
- |
0 |
|
- |
| 13.7.2 (elec)(Uniformity of Zinc coating) |
- |
0 |
|
- |
| 13.7.2 (elec)(Mass of Zinc coating) |
- |
0 |
|
- |
| 13.5.2 (elec)(Wrapping Test Galvanized Steel Wires After Stranding) |
- |
0 |
|
- |
| 13.5.2 (elec)(Wrapping Test Galvanized Steel Wires Before Stranding) |
- |
0 |
|
- |
| 13.5.1 (elec)(Wrapping Test Aluminium Wires After Stranding) |
- |
0 |
|
- |
| 13.5.1 (elec)(Wrapping Test Aluminium Wires Before Stranding) |
- |
0 |
|
- |
| 13.4.1 (elec)(Ductility by Torsion Test after stranding) |
- |
0 |
|
- |
| 13.4.1 (elec)(Ductility by Torsion Test after stranding) |
- |
0 |
|
- |
| 13.4.1 (elec)(Ductility by Torsion Test before stranding) |
- |
0 |
|
- |
| 13.4.1 (elec)(Ductility by Torsion Test before stranding) |
- |
0 |
|
- |
| 13.3 Table 2 (elec)(Breaking Load of Steel Wires After Stranding) |
- |
0 |
|
- |
| 13.3 Table 1 (elec)(Breaking Load of Steel Wires After Stranding) |
- |
0 |
|
- |
| 13.3 Table 1 (elec)(Breaking Load of Aluminium Wires Before Stranding) |
- |
0 |
|
- |
| 10 (elec)(Stranding) |
- |
0 |
|
- |
| 8.1.1 & 13.2 Table 2 (elec)(Diameter of Steel Wires After Stranding) |
- |
0 |
|
- |
| 8.1.1 & 13.2 Table-1 (elec)(Diameter of Aluminium Wires After Stranding) |
- |
0 |
|
- |
| 8.1.1 & 13.2 Table 2 (elec)(Diameter of Steel Wires Before Stranding) |
- |
0 |
|
- |
| 8.1.1 & 13.2 Table-1 (elec)(Diameter of Aluminium Wires Before Stranding) |
- |
0 |
|
- |
|
- |
- Included w.e.f. 17.11.2023. Restricted up to 100 sq. mm: [Cl.13.9 (Surface condition test), Cl. 13.10 (Ultimate breaking load), Cl. 13.11 (Stress-strain test)] |
| 7735 |
Alpha Test House Private Limited, Delhi
| 8131026
| IS 398 : Part 1 (1996) |
Aluminium conductors for overhead transmission purposes - Specification: Part 1 aluminium stranded conductors (Third Revision) |
- |
5625 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 12.2, Table-1(Measurement of diameter of individual aluminium wire) |
- |
750 |
|
- |
| 12.3, Table-1(Breaking load before stranding) |
- |
750 |
|
- |
| 12.3, Table-1(Breaking load after stranding) |
- |
750 |
|
- |
| 12.4(Wrapping test) |
- |
350 |
|
- |
| 12.5, Table 1(Resistance test) |
- |
1000 |
|
- |
| 12.6, Table 3(Measurement of lay ratio) |
- |
400 |
|
- |
| 9.3(Stranding) |
- |
50 |
|
- |
| 6(Freedom from defects) |
- |
50 |
|
- |
| 12.2, Table-1(Measurement of diameter of individual aluminium wire) |
- |
0 |
|
- |
| 12.3, Table-1(Breaking load before stranding) |
- |
0 |
|
- |
| 12.3, Table-1(Breaking load after stranding) |
- |
0 |
|
- |
| 12.4(Wrapping test) |
- |
0 |
|
- |
| 12.5, Table 1(Resistance test) |
- |
0 |
|
- |
| 12.6, Table 3(Measurement of lay ratio) |
- |
0 |
|
- |
| 9.3(Stranding) |
- |
0 |
|
- |
| 6(Freedom from defects) |
- |
0 |
|
- |
| 12.3, Table-1(Breaking load after stranding) |
- |
750 |
|
- |
| 12.4(Wrapping test) |
- |
700 |
|
- |
|
- |
- Included w.e.f. 17.11.2023 |
| 7736 |
Alpha Test House Private Limited, Delhi
| 8131026
| IS 302 : Part 2 : Sec 3 (2007) |
Safety of household and similar electrical appliances: Part 2 particular requirements: Sec 3 electric iron (First Revision) |
- |
3500 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 7.14(Marking- IS 302-1) |
- |
100 |
|
Testing charges |
| 8( Protection Against Electric Shock, IS 302-1) |
- |
150 |
|
Testing charges |
| 10(Power Input and Current, IS 302-1) |
- |
150 |
|
Testing charges |
| 11(Heating, IS 302-1) |
- |
150 |
|
Testing charges |
| 13(Electrical Insulation and Leakage Current at Operating Temperature: Leakage current, IS 302-1) |
- |
150 |
|
Testing charges |
| 13(Electrical Insulation and Leakage Current at Operating Temperature: High Voltage, IS 302-1) |
- |
0 |
|
Testing charges |
| 14(Transient Over Voltages, IS 302-1) |
- |
150 |
|
Testing charges |
| 15.1(Moisture Resistance, IS 302-1) |
- |
75 |
|
Testing charges |
| 15.3(Moisture Resistance, IS 302-1) |
- |
75 |
|
Testing charges |
| 16(Electrical Insulation and Leakage Current at Operating Temperature: Leakage current, IS 302-1) |
- |
150 |
|
Testing charges |
| 16(Electrical Insulation and Leakage Current at Operating Temperature: High Voltage, IS 302-1) |
- |
0 |
|
Testing charges |
| 19.4(Abnormal Operation, IS 302-1) |
- |
50 |
|
Testing charges |
| 19.5(Abnormal Operation, IS 302-1) |
- |
50 |
|
Testing charges |
| 19.7(Abnormal Operation) |
- |
0 |
|
Testing charges |
| 19.9(Abnormal Operation) |
- |
50 |
|
Testing charges |
| 20.1(Stability & Mechanical Hazards, IS 302-1) |
- |
100 |
|
Testing charges |
| 20.2(Stability & Mechanical Hazards, IS 302-1) |
- |
50 |
|
Testing charges |
| 21.1(Mechanical Strength, IS 302-1) |
- |
50 |
|
Testing charges |
| 21.2(Mechanical Strength, IS 302-1) |
- |
50 |
|
Testing charges |
| 21.101(Mechanical Strength, IS 302-2-3) |
- |
50 |
|
Testing charges |
| 22(Construction, IS 302-1) |
- |
75 |
|
Testing charges |
| 22.104(Construction) |
- |
75 |
|
Testing charges |
| 23.5(Internal Wiring, IS 302-1) |
- |
150 |
|
Testing charges |
| 24.1(Components, IS 302-1) |
- |
100 |
|
Testing charges |
| 24.6(Components, IS 302-1) |
- |
50 |
|
Testing charges |
| 25.2(Supply Connection and External Flexible Cords, IS 302-1) |
- |
50 |
|
Testing charges |
| 25.14(Supply Connection and External Flexible Cords, IS 302-1) |
- |
50 |
|
Testing charges |
| 25.15(Supply Connection and External Flexible Cords, IS 302-1) |
- |
50 |
|
Testing charges |
| 25.21(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
Testing charges |
| 26(Terminals for External Conductors, IS 302-1) |
- |
150 |
|
Testing charges |
| 27.2(Provision for Earthing, IS 302-1) |
- |
50 |
|
Testing charges |
| 27.5(Provision for Earthing, IS 302-1) |
- |
100 |
|
Testing charges |
| 28(Screws & Connections, IS 302-1) |
- |
150 |
|
Testing charges |
| 29.1(Clearances, Creepage distances and Solid Insulation, IS 302-1) |
- |
75 |
|
Testing charges |
| 29.2(Clearances, Creepage distances and Solid Insulation, IS 302-1) |
- |
75 |
|
Testing charges |
| 30.1(Resistance to Heat, Fire & Tracking, IS 302-1) |
- |
150 |
|
Testing charges |
| 30.2(Resistance to Heat, Fire & Tracking, IS 302-1) |
- |
150 |
|
Testing charges |
| 31(Resistance of Rusting, IS 302-1) |
- |
150 |
|
Testing charges |
|
- |
- Restricted to Dry Iron only. |
| 7737 |
Alpha Test House Private Limited, Delhi
| 8131026
| IS 3854 (1997) |
Switches for domestic and similar purposes - Specification (Second Revision) |
- |
10000.00 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 8(Marking) |
- |
20 |
|
- |
| 8(Marking) |
- |
20 |
|
- |
| 8(Marking) |
- |
20 |
|
- |
| 8(Marking) |
- |
20 |
|
- |
| 8(Marking) |
- |
20 |
|
- |
| 8(Marking) |
- |
20 |
|
- |
| 8(Marking) |
- |
20 |
|
- |
| 8(Marking) |
- |
20 |
|
- |
| 8(Marking) |
- |
20 |
|
- |
| 8.9(Marking) |
- |
20 |
|
Test |
| 8(Marking) |
- |
20 |
|
- |
| 6(Rating) |
- |
20 |
|
- |
| 6(Rating) |
- |
20 |
|
- |
| 7(Classification) |
- |
20 |
|
- |
| 7(Classification) |
- |
20 |
|
- |
| 7(Classification) |
- |
20 |
|
- |
| 7(Classification) |
- |
20 |
|
- |
| 7(Classification) |
- |
20 |
|
- |
| 7(Classification) |
- |
20 |
|
- |
| 7(Classification) |
- |
20 |
|
- |
| 7(Classification) |
- |
20 |
|
- |
| 7(Classification) |
- |
20 |
|
- |
| 10(Protection against Electric Shock) |
- |
20 |
|
Test |
| 11.1(Provision for earthing) |
- |
20 |
|
Test |
| 12(Terminals) |
- |
20 |
|
Test |
| 12.2.1(Terminals) |
- |
20 |
|
- |
| 12(Terminals) |
- |
20 |
|
- |
| 12.2.2(Connection of conductor) |
- |
20 |
|
- |
| 12.2.3(Mechanical strength of terminals) |
- |
20 |
|
- |
| 12.2.3(Mechanical strength of terminals) |
- |
20 |
|
- |
| 12.2.4(Resistance to corrosion) |
- |
20 |
|
- |
| 12.2.4(Resistance to corrosion) |
- |
20 |
|
- |
| 12.2.5(Undue damage to conductor) |
- |
50 |
|
Test |
| 12.2.7(Insertion of conductor) |
- |
20 |
|
Test |
| 12.2.9(Locking against accidental loosening) |
- |
20 |
|
Test |
| 12.2.11(Distance between screw and conductor) |
- |
20 |
|
Test |
| 12.2.11(Distance between screw and conductor) |
- |
20 |
|
- |
| 12.3.2(Screwless terminals) |
- |
20 |
|
Test |
| 12.3.3(Connectin of conductor) |
- |
20 |
|
- |
| 12.3.4(Material of terminals) |
- |
20 |
|
- |
| 12.3.5(Clamping) |
- |
20 |
|
Test |
| 12.3.5(Clamping) |
- |
20 |
|
- |
| 12.3.7(v) Interconnection of conductors [Cl. 12.3.7]) |
- |
20 |
|
- |
| 12.3.7(v) Interconnection of conductors [Cl. 12.3.7]) |
- |
20 |
|
- |
| 12.3.11(vi) Electrical & Thermal Stresses [Cl 12.3.11]) |
- |
20 |
|
Test |
| 12.3.11(vi) Electrical & Thermal Stresses [Cl 12.3.11]) |
- |
20 |
|
- |
| 12.3.12(vii) Deflection Stresses [Cl. 12.3.12]) |
- |
20 |
|
Test |
| 13.1(a) Insulating lining, barriers and the like [Cl 13.1]) |
- |
20 |
|
- |
| 13.2(b) Construction of switch [Cl 13.2]) |
- |
20 |
|
- |
| 13.2(i) Installation Test) |
- |
20 |
|
Test |
| 13.3(c) Covers,cover plates and actuating members [Cl 13.3]) |
- |
20 |
|
Test |
| 13.4(d) Ordinary switches [Cl 13.4]) |
- |
20 |
|
Test |
| 13.5(e) Rotary switches [Cl 13.5]) |
- |
20 |
|
Test |
| 13.6(f) Screws and other means [Cl 13.6]) |
- |
20 |
|
- |
| 13.7(g) Combination of switches or switches and socket outlets [Cl 13.7]) |
- |
20 |
|
- |
| 13.8(h) Assessories combined with switches [Cl. 13.8]) |
- |
20 |
|
- |
| 13.9(j) Switches other than ordinary switches [Cl. 13.9]) |
- |
20 |
|
Test |
| 13.9(j) Switches other than ordinary switches [Cl. 13.9]) |
- |
20 |
|
- |
| 13.9(j) Switches other than ordinary switches [Cl. 13.9]) |
- |
20 |
|
- |
| 13.9(j) Switches other than ordinary switches [Cl. 13.9]) |
- |
20 |
|
- |
| 13.9(j) Switches other than ordinary switches [Cl. 13.9]) |
- |
20 |
|
- |
| 13.9(j) Switches other than ordinary switches [Cl. 13.9]) |
- |
20 |
|
- |
| 13.9(j) Switches other than ordinary switches [Cl. 13.9]) |
- |
20 |
|
- |
| 13.1(k) Switches to be installed in a box [Cl. 13.10]) |
- |
20 |
|
- |
| 13.11(l) Surface type switches other than ordinary switch [Cl. 13.11]) |
- |
20 |
|
Test |
| 13.12, 13.13, 13.14(m) Inlet opening [Cl. 13.12.13.13 & 13.14]) |
- |
20 |
|
Test |
| 13.15(q) Requirements for membrane in inlet opening [ Cl. 13.15]) |
- |
20 |
|
Test |
| 13.15(q) Requirements for membrane in inlet opening [ Cl. 13.15]) |
- |
20 |
|
- |
| 13.15(q) Requirements for membrane in inlet opening [ Cl. 13.15]) |
- |
20 |
|
- |
| 13.15(q) Requirements for membrane in inlet opening [ Cl. 13.15]) |
- |
20 |
|
- |
| 14(Mechanism [Cl. 14]) |
- |
20 |
|
- |
| 14.4(Mechanism) |
- |
20 |
|
Test |
| 15.1(Resistance to Ageing, to Harmful Ingress of water and to Humidity [Cl. 15]: Resistance to Ageing, [Cl. 15.1]) |
- |
100 |
|
Test |
| 15.2(b)Resistance to Harmful ingress of water [Cl. 15.2]) |
- |
100 |
|
Test |
| 15.2(b)Resistance to Harmful ingress of water [Cl. 15.2]) |
- |
100 |
|
- |
| 15.3(c) Resistance to Humidity [Cl. 15.3]) |
- |
200 |
|
Test |
| 16.1(Insulation resistance [Cl. 16.1]) |
- |
200 |
|
Test |
| 16.2( Electric Strength [Cl. 16.2]) |
- |
200 |
|
Test |
| 17(Temperature- rise [Cl. 17]) |
- |
200 |
|
Test |
| 18(Marking and breaking Capacity[Cl. 18]) |
- |
250 |
|
- |
| 18(Marking and breaking Capacity[Cl. 18]) |
- |
250 |
|
Test |
| 19(Normal Operation [Cl. 19] a) General & Operation) |
- |
500 |
|
- |
| 19.2(Normal Operation (For AX type Switches) [Cl. 19.2]) |
- |
500 |
|
- |
| 19(b) Electric Strength) |
- |
200 |
|
- |
| 19(c)Temperature-rise ) |
- |
200 |
|
- |
| 14.3(d)Test for arcing and sparking [Cl 14.3]) |
- |
200 |
|
Test |
| 19.2(Normal Operation (For AX type Switches) [Cl. 19.2]) |
- |
200 |
|
Test |
| 20(Mechanical Strength Test [Cl. 20]) |
- |
20 |
|
Test |
| 21(Resistance to Heat [Cl.21]) |
- |
20 |
|
Test |
| 21(Resistance to Heat [Cl.21]) |
- |
20 |
|
- |
| 21(Resistance to Heat [Cl.21]) |
- |
20 |
|
- |
| 22(Screw, Current Carrying Part And Connection [Cl.22]) |
- |
20 |
|
- |
| 22.1(i) Screw & Nuts [Cl.22.1]) |
- |
20 |
|
Test |
| 22.4(ii) Screw & rivets [Cl . 22.4]) |
- |
20 |
|
- |
| 22.3(iii) Electrical Connections [Cl.22.3]) |
- |
20 |
|
- |
| 22.5(iv) Current carrying part [Cl.22.5]) |
- |
20 |
|
- |
| 23.2(Creepage distances, clearances and distance through sealing compound [Cl.23]) |
- |
20 |
|
Test |
| 23(Creepage distances, clearances and distance through sealing compound [Cl.23]) |
- |
20 |
|
- |
| 23(Creepage distances, clearances and distance through sealing compound [Cl.23]) |
- |
20 |
|
- |
| 24.1.1(Resistance to Abnormal Heat & Fire [Cl.24.1] [Glow Wire Test] [Cl.24.1.1]) |
- |
200 |
|
Test |
| 24.2(Resistance to tracking [For Switch other than ordinary] [Cl.24.2]) |
- |
200 |
|
Test |
| 24.2(Resistance to tracking [For Switch other than ordinary] [Cl.24.2]) |
- |
200 |
|
- |
| 25 of IS 3854 : 1997(Resistance to rusting) |
- |
200 |
|
- |
| 11.3(Provision for earthing) |
- |
20 |
|
- |
| 11.2(Provision for earthing) |
- |
20 |
|
- |
| 12.3.9(Screwless terminal fixing) |
- |
20 |
|
- |
| 12.3.8(Screwless terminals design) |
- |
20 |
|
- |
| 12.3.6(Connection) |
- |
20 |
|
- |
| 12.3.1(Screwless terminals) |
- |
20 |
|
- |
| 14.6(Mechanism) |
- |
20 |
|
- |
| 14.5(Mechanism) |
- |
20 |
|
- |
| 16.3(Flash test) |
- |
20 |
|
- |
| 20.8(Mechanical Strength Test) |
- |
20 |
|
- |
| 20.7(Mechanical Strength Test) |
- |
20 |
|
- |
| 20.6(Mechanical Strength Test) |
- |
20 |
|
- |
| 20.5(Mechanical Strength Test) |
- |
20 |
|
- |
| 20.4(Mechanical Strength Test) |
- |
20 |
|
- |
| 20.3(Mechanical Strength Test) |
- |
20 |
|
- |
| 20.2(Mechanical Strength Test) |
- |
20 |
|
- |
| 20.1(Mechanical Strength Test) |
- |
20 |
|
- |
| 21.2(Resistance to Heat) |
- |
20 |
|
- |
| 21.1(Resistance to Heat) |
- |
20 |
|
- |
| 22.2(Measurement and manual test) |
- |
20 |
|
- |
| 22.6(Inspection and chemical analysis) |
- |
20 |
|
- |
| 24.1(Resistance of insulating material to abnormal heat, to fire and to tracking
) |
- |
200 |
|
- |
| 24(Resistance of insulating material to abnormal heat, to fire and to tracking
) |
- |
200 |
|
- |
| 23.2(Creepage distances,
clearances & distance through
sealing compound
) |
- |
20 |
|
- |
| 23.1(Creepage distances,
clearances & distance through
sealing compound
) |
- |
20 |
|
- |
| 22.7(Screws, current
carrying parts and connections
) |
- |
20 |
|
- |
| 22.6(Screws, current
carrying parts and connections
) |
- |
20 |
|
- |
| 22.5(Screws, current
carrying parts and connections
) |
- |
20 |
|
- |
| 22.4(Screws, current
carrying parts and connections
) |
- |
20 |
|
- |
| 22.3(Screws, current
carrying parts and connections
) |
- |
20 |
|
- |
| 22.2(Screws, current
carrying parts and connections
) |
- |
20 |
|
- |
| 22.1(Screws, current
carrying parts and connections
) |
- |
20 |
|
- |
| 21.3(Resistance to heat
) |
- |
40 |
|
- |
| 21.2(Resistance to heat
) |
- |
20 |
|
- |
| 21.1(Resistance to heat
) |
- |
20 |
|
- |
| 20.9(Mechanical
strength
) |
- |
20 |
|
- |
| 20.8(Mechanical
strength
) |
- |
10 |
|
- |
| 20.7(Mechanical
strength
) |
- |
10 |
|
- |
| 20.6 & 24.4.2(Mechanical
strength
) |
- |
20 |
|
- |
| 20.6 & 24.4.1(Mechanical
strength
) |
- |
20 |
|
- |
| 20.5 & 24.4.2(Mechanical
strength
) |
- |
20 |
|
- |
| 20.5 & 24.4.1(Mechanical
strength
) |
- |
20 |
|
- |
| 20.4.2(Mechanical
strength
) |
- |
20 |
|
- |
| 20.4.1(Mechanical
strength
) |
- |
20 |
|
- |
| 20.4(Mechanical
strength
) |
- |
20 |
|
- |
| 20.3(Mechanical
strength
) |
- |
20 |
|
- |
| 20.2(Mechanical
strength
) |
- |
20 |
|
- |
| 20.1(Mechanical
strength
) |
- |
20 |
|
- |
| 19.2(Normal operation) |
- |
20 |
|
- |
| 19.1(Normal operation) |
- |
500 |
|
- |
| 18.2(Making and breaking capacity ) |
- |
200 |
|
- |
| 18.1(Making and breaking capacity ) |
- |
200 |
|
- |
| 16.3(Insulation
resistance and electric strength
) |
- |
100 |
|
- |
| 16(Insulation
resistance and electric strength
) |
- |
100 |
|
- |
| 15.3(Resistance to ageing, to harmful ingress of water and to humidity
) |
- |
100 |
|
- |
| 15.2.3(Resistance to ageing, to harmful ingress of water and to humidity
) |
- |
100 |
|
- |
| 15.2.2(Resistance to ageing, to harmful ingress of water and to humidity
) |
- |
100 |
|
- |
| 15.2.1(Resistance to ageing, to harmful ingress of water and to humidity
) |
- |
100 |
|
- |
| 15.2(Resistance to ageing, to harmful ingress of water and to humidity
) |
- |
100 |
|
- |
| 15.1(Resistance to ageing, to harmful ingress of water and to humidity
) |
- |
100 |
|
- |
| 15(Resistance to ageing, to harmful ingress of water and to humidity
) |
- |
100 |
|
- |
| 14.6(Mechanism) |
- |
10 |
|
- |
| 14.5(Mechanism) |
- |
10 |
|
- |
| 14.4(Mechanism) |
- |
10 |
|
- |
| 14.3(Mechanism) |
- |
10 |
|
- |
| 14.2(Mechanism) |
- |
10 |
|
- |
| 14.1(Mechanism) |
- |
20 |
|
- |
| 13.15.2(Constructional
requirements
) |
- |
20 |
|
- |
| 13.15.1(Constructional
requirements
) |
- |
20 |
|
- |
| 13.15(Constructional
requirements
) |
- |
20 |
|
- |
| 13.14(Constructional
requirements
) |
- |
20 |
|
- |
| 13.13(Constructional
requirements
) |
- |
20 |
|
- |
| 13.12(Constructional
requirements
) |
- |
20 |
|
- |
| 13.11(Constructional
requirements
) |
- |
20 |
|
- |
| 13.1(Constructional
requirements
) |
- |
20 |
|
- |
| 13.9(Constructional
requirements
) |
- |
20 |
|
- |
| 13.8(Constructional
requirements
) |
- |
20 |
|
- |
| 13.7(Constructional
requirements
) |
- |
20 |
|
- |
| 13.6(Constructional
requirements
) |
- |
20 |
|
- |
| 13.5(Constructional
requirements
) |
- |
20 |
|
- |
| 13.4(Constructional
requirements
) |
- |
20 |
|
- |
| 13.3.3(Constructional
requirements
) |
- |
20 |
|
- |
| 13.3.2(Constructional
requirements
) |
- |
20 |
|
- |
| 13.3.1(Constructional
requirements
) |
- |
20 |
|
- |
| 13.3(Constructional
requirements
) |
- |
20 |
|
- |
| 13.2(Constructional
requirements
) |
- |
20 |
|
- |
| 13.1(Constructional
requirements
) |
- |
20 |
|
- |
| 13(Constructional
requirements
) |
- |
20 |
|
- |
| 12.3.12(Terminals) |
- |
20 |
|
- |
| 12.3.11.b(Terminals) |
- |
20 |
|
- |
| 12.3.11.a(Terminals) |
- |
20 |
|
- |
| 12.3.10(Terminals) |
- |
20 |
|
- |
| 12.3.9(Terminals) |
- |
20 |
|
- |
| 12.3.8(Terminals) |
- |
20 |
|
- |
| 12.3.6(Terminals) |
- |
20 |
|
- |
| 12.2.6(Terminals) |
- |
20 |
|
- |
| 12.2(Terminals) |
- |
20 |
|
- |
| 12.1(Terminals) |
- |
20 |
|
- |
| 11.4(Provision for earthing) |
- |
20 |
|
- |
| 11.3(Provision for earthing) |
- |
20 |
|
- |
| 11.2(Provision for earthing) |
- |
20 |
|
- |
| 11.1(Provision for earthing) |
- |
20 |
|
- |
| 10.7(Protection against electric shock
) |
- |
20 |
|
- |
| 10.6(Protection against electric shock
) |
- |
20 |
|
- |
| 10.5(Protection against electric shock
) |
- |
20 |
|
- |
| 10.4(Protection against electric shock
) |
- |
20 |
|
- |
| 10.3.2(Protection against electric shock
) |
- |
20 |
|
- |
| 10.3.1(Protection against electric shock
) |
- |
20 |
|
- |
| 10.3(Protection against electric shock
) |
- |
20 |
|
- |
| 10.2(Protection against electric shock
) |
- |
20 |
|
- |
| 10.1(Protection against electric shock
) |
- |
20 |
|
- |
| 8.1(Marking) |
- |
20 |
|
- |
| 8.8(Marking) |
- |
20 |
|
- |
| 8.7(Marking) |
- |
20 |
|
- |
| 8.6(Marking) |
- |
20 |
|
- |
| 8.5(Marking) |
- |
20 |
|
- |
| 8.4(Marking) |
- |
20 |
|
- |
| 8.3(Marking) |
- |
20 |
|
- |
| 8.2(Marking) |
- |
20 |
|
- |
| 8.1(Marking) |
- |
20 |
|
- |
| 7.2(Classification) |
- |
20 |
|
- |
| 7.1.8(Classification) |
- |
20 |
|
- |
| 7.1.7(Classification) |
- |
20 |
|
- |
| 7.1.6(Classification) |
- |
20 |
|
- |
| 7.1.5(Classification) |
- |
20 |
|
- |
| 7.1.4(Classification) |
- |
20 |
|
- |
| 7.1.3(Classification) |
- |
20 |
|
- |
| 7.1.2(Classification) |
- |
20 |
|
- |
| 7.1.1(Classification) |
- |
20 |
|
- |
| 7.1(Classification) |
- |
20 |
|
- |
| 6.2(Ratings) |
- |
20 |
|
- |
| 6.1(Ratings) |
- |
20 |
|
- |
| 6(Ratings) |
- |
20 |
|
- |
| 25(Resistance to Rusting) |
- |
200 |
|
- |
|
- |
- Included w.e.f.
11.10.2018 |
| 7738 |
Alpha Test House Private Limited, Delhi
| 8131026
| IS 1293 (2005) |
Plugs and socket- outlets of rated voltage up to and including 250 volts and rated current up to 16 amperes |
250 Volts and rated current up to and including 16 A |
15000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 29.0(Resistance to Rusting) |
- |
100 |
|
- |
| 28.2(Resistance to Tracking) |
- |
100 |
|
- |
| 28.1.1(Glow-Wire Test ) |
- |
100 |
|
- |
| 27.3(Creepage distances, clearances and distances through sealing compound ) |
- |
20 |
|
- |
| 27.2(Creepage distances, clearances and distances through sealing compound ) |
- |
20 |
|
- |
| 27.1(Creepage distances, clearances and distances through sealing compound ) |
- |
20 |
|
- |
| 26.7(Screws, current carrying parts and connections) |
- |
20 |
|
- |
| 26.2(Screws, current carrying parts and connections) |
- |
20 |
|
- |
| 26.1(Screws, current carrying parts and connections) |
- |
20 |
|
- |
| 25.4(Resistance to heat) |
- |
100 |
|
- |
| 25.3(Resistance to heat) |
- |
100 |
|
- |
| 25.2(Resistance to heat) |
- |
100 |
|
- |
| 25.1(Resistance to heat) |
- |
100 |
|
- |
| 25.1(Resistance to heat) |
- |
100 |
|
- |
| 24.14.2(f)Verification of the Removal of Covers or Cover-Plates ) |
- |
20 |
|
- |
| 24.14.1(e)Verification of the Non-removal of Covers or Cover-Plates ) |
- |
20 |
|
- |
| 24.8(c) For shuttered socket-outlets ) |
- |
20 |
|
- |
| 24.6(b) For screwed glands of accessories other than ordinary) |
- |
20 |
|
- |
| 24.3(a) For surface type socket outlet) |
- |
20 |
|
- |
| 24.1(a) Mechanical Strength
) |
- |
20 |
|
- |
| 22.2(Verification of Minimum withdrawal force) |
- |
20 |
|
- |
| 22.1(Verification of Max withdrawal force) |
- |
20 |
|
- |
| 21.0(Normal Operation) |
- |
300 |
|
- |
| 21.0(Normal Operation) |
- |
300 |
|
- |
| 21.0(Normal Operation) |
- |
300 |
|
- |
| 21.0(Normal Operation) |
- |
300 |
|
- |
| 20.0(Making & Breaking Capacity) |
- |
300 |
|
- |
| 19.0(Temperature Rise ) |
- |
100 |
|
- |
| 18.0(Operation of Earthing Contacts) |
- |
20 |
|
- |
| 17.2( Electric Strength) |
- |
100 |
|
- |
| 17.1(Insulation Resistance) |
- |
100 |
|
- |
| 16.3(Resistance to humidity) |
- |
100 |
|
- |
| 16.2(Resistance to Harmful Ingress of Water) |
- |
20 |
|
- |
| 16.1(Resistance to Ageing ) |
- |
100 |
|
- |
| 15.0(Interlocked socket-outlets) |
- |
20 |
|
- |
| 13.17(Construction of fixed Socket Outlets) |
- |
20 |
|
- |
| 13.14(Construction of fixed Socket Outlets) |
- |
20 |
|
- |
| 13.16(Construction of fixed Socket Outlets) |
- |
20 |
|
- |
| 13.1(Construction of fixed Socket Outlets) |
- |
20 |
|
- |
| 13.9(Construction of fixed Socket Outlets) |
- |
20 |
|
- |
| 13.5(Construction of fixed Socket Outlets) |
- |
20 |
|
- |
| 13.4(Construction of fixed Socket Outlets) |
- |
20 |
|
- |
| 13.4(Construction of fixed Socket Outlets) |
- |
20 |
|
- |
| 13.4(Construction of fixed Socket Outlets) |
- |
20 |
|
- |
| 13.4(Construction of fixed Socket Outlets) |
- |
20 |
|
- |
| 13.4(Construction of fixed Socket Outlets) |
- |
20 |
|
- |
| 13.3(Construction of fixed Socket Outlets) |
- |
20 |
|
- |
| 13.2(Construction of fixed Socket Outlets) |
- |
20 |
|
- |
| 13.1(Construction of fixed Socket Outlets) |
- |
20 |
|
- |
| 12.2.11(Terminals) |
- |
20 |
|
- |
| 12.2.10(Terminals) |
- |
20 |
|
- |
| 12.2.9(Terminals) |
- |
20 |
|
- |
| 12.2.7(Terminals) |
- |
20 |
|
- |
| 12.2.5(Terminals) |
- |
20 |
|
- |
| 12.2.4(Terminals) |
- |
20 |
|
- |
| 12.2.3(Terminals) |
- |
20 |
|
- |
| 12.2.2(Terminals) |
- |
20 |
|
- |
| 12.2.1(Terminals) |
- |
20 |
|
- |
| 11.5(Provision for Earthing) |
- |
20 |
|
- |
| 11.2(Provision for Earthing) |
- |
20 |
|
- |
| 11.1(Provision for Earthing) |
- |
20 |
|
- |
| 10.6(Protection against Electric Shock) |
- |
20 |
|
- |
| 10.5(Protection against Electric Shock) |
- |
20 |
|
- |
| 10.3(Protection against Electric Shock) |
- |
20 |
|
- |
| 10.1(Protection against Electric Shock) |
- |
20 |
|
- |
| 10.1(Protection against Electric Shock) |
- |
20 |
|
- |
| 9.0(16 A) |
- |
20 |
|
- |
| 9.0(16 A) |
- |
20 |
|
- |
| 9.0(16 A) |
- |
20 |
|
- |
| 9.0(6A/10A ) |
- |
20 |
|
- |
| 9.0(6A/10A ) |
- |
20 |
|
- |
| 9.0(6A/10A ) |
- |
20 |
|
- |
| 9.0(Checking of dimensions) |
- |
20 |
|
- |
| 8.0(Marking) |
- |
20 |
|
- |
| 8.0(Marking) |
- |
20 |
|
- |
| 8.0(Marking) |
- |
20 |
|
- |
| 8.0(Marking) |
- |
20 |
|
- |
| 8.0(Marking) |
- |
20 |
|
- |
| 8.0(Marking) |
- |
20 |
|
- |
| 8.0(Marking) |
- |
20 |
|
- |
| 8.0(Marking) |
- |
20 |
|
- |
| 8.0(Marking) |
- |
20 |
|
- |
| 8.0(Marking) |
- |
20 |
|
- |
| 7.0(Classification) |
- |
20 |
|
- |
| 7.0(Classification) |
- |
20 |
|
- |
| 7.0(Classification) |
- |
20 |
|
- |
| 7.0(Classification) |
- |
20 |
|
- |
| 7.0(Classification) |
- |
20 |
|
- |
| 7.0(Classification) |
- |
20 |
|
- |
| 7.0(Classification) |
- |
20 |
|
- |
| 7.0(Classification) |
- |
20 |
|
- |
| 7.0(Classification) |
- |
20 |
|
- |
| 7.0(Classification) |
- |
20 |
|
- |
| 6.0(Ratings) |
- |
20 |
|
- |
| 6.0(Ratings) |
- |
20 |
|
- |
| 30.4(Addiitional tests on pins provided with insulating sleeves - Tests at Low Temperature) |
- |
100 |
|
- |
| 30.3(Addiitional tests on pins provided with insulating sleeves - Impact Test at Low Temperature) |
- |
100 |
|
- |
| 30.2(Addiitional tests on pins provided with insulating sleeves - Static Damp Heat Test) |
- |
100 |
|
- |
| 30.1(Addiitional tests on pins provided with insulating sleeves - Pressure Test at High Temperature) |
- |
100 |
|
- |
| 30.4(Addiitional tests on pins provided with insulating sleeves - Tests at Low Temperature) |
- |
100 |
|
- |
| 30.3(Addiitional tests on pins provided with insulating sleeves - Impact Test at Low Temperature) |
- |
100 |
|
- |
| 30.2(Addiitional tests on pins provided with insulating sleeves - Static Damp Heat Test) |
- |
100 |
|
- |
| 30.1(Addiitional tests on pins provided with insulating sleeves - Pressure Test at High Temperature) |
- |
100 |
|
- |
| 28.1.2(Addiitional tests for plugs with pins provided with insulating sleeves) |
- |
100 |
|
- |
| 24.18(Verification of the Removal of Covers or Cover-Plates ) |
- |
20 |
|
- |
| 24.17(Verification of the Removal of Covers or Cover-Plates ) |
- |
20 |
|
- |
| 24.16(Verification of the Removal of Covers or Cover-Plates ) |
- |
20 |
|
- |
| 24.15(Verification of the Removal of Covers or Cover-Plates ) |
- |
20 |
|
- |
| 24.13(For portable socket outlets having means for suspension on a wall) |
- |
20 |
|
- |
| 24.12(For portable socket outlets having means for suspension on a wall) |
- |
20 |
|
- |
| 24.11(For portable socket outlets having means for suspension on a wall) |
- |
20 |
|
- |
| 24.1(For plugs) |
- |
20 |
|
- |
| 24.9(For portable multiple and combined socket outlets) |
- |
20 |
|
- |
| 24.7(For plug pins provided with insulating sleeves) |
- |
20 |
|
- |
| 24.5(For Portable single socket outlets/ plugs) |
- |
20 |
|
- |
| 24.4(For Portable socket outlets/ plugs) |
- |
20 |
|
- |
| 24.2(For Portable single socket outlets/ plugs) |
- |
20 |
|
- |
| 23.4(Flexible cables & their connection ) |
- |
20 |
|
- |
| 23.3(Flexible cables & their connection ) |
- |
20 |
|
- |
| 23.2(Flexible cables & their connection ) |
- |
20 |
|
- |
| 23.1(Flexible cables & their connection ) |
- |
20 |
|
- |
| 14.15(Construction of Plugs & Portables socket outlet ) |
- |
20 |
|
- |
| 14.11(Construction of Plugs & Portables socket outlet ) |
- |
20 |
|
- |
| 14.1(Construction of Plugs & Portables socket outlet ) |
- |
20 |
|
- |
| 14.9(Construction of Plugs & Portables socket outlet ) |
- |
20 |
|
- |
| 14.9(Construction of Plugs & Portables socket outlet ) |
- |
20 |
|
- |
| 14.8(Construction of Plugs & Portables socket outlet ) |
- |
20 |
|
- |
| 14.7(Construction of Plugs & Portables socket outlet ) |
- |
20 |
|
- |
| 14.3(Construction of Plugs & Portables socket outlet ) |
- |
20 |
|
- |
| 14.2(Construction of Plugs & Portables socket outlet ) |
- |
20 |
|
- |
| 14.1(Construction of Plugs & Portables socket outlet ) |
- |
20 |
|
- |
| 12.1(Terminals) |
- |
20 |
|
- |
| 10.4(Protection against Electric Shock) |
- |
20 |
|
- |
| 10.1(Protection against Electric Shock) |
- |
20 |
|
- |
| 10.1(Protection against Electric Shock) |
- |
20 |
|
- |
| 9(16 A) |
- |
20 |
|
- |
| 9(16 A) |
- |
20 |
|
- |
| 9(16 A) |
- |
20 |
|
- |
| 9(6A/10A ) |
- |
20 |
|
- |
| 9(16 A) |
- |
20 |
|
- |
| 9(6A/10A ) |
- |
20 |
|
- |
| 9(6A/10A ) |
- |
20 |
|
- |
| 9(6A/10A ) |
- |
20 |
|
- |
| 9(6A/10A ) |
- |
20 |
|
- |
| 8(Marking) |
- |
20 |
|
- |
| 28.1.2(RESISTANCE OF INSULATING MATERIAL TO ABNORMAL HEAT, TO FIRE AND TO TRACKING) |
- |
100 |
|
- |
| 28.1(RESISTANCE OF INSULATING MATERIAL TO ABNORMAL HEAT, TO FIRE AND TO TRACKING) |
- |
100 |
|
- |
| 27(CREEPAGE DISTANCES, CLEARANCES AND DISTANCES THROUGH SEALING COMPOUND) |
- |
20 |
|
- |
| 26.6(SCREWS, CURRENT-CARRYING PARTS AND CONNECTIONS) |
- |
20 |
|
- |
| 26.5(SCREWS, CURRENT-CARRYING PARTS AND CONNECTIONS) |
- |
20 |
|
- |
| 26.4(SCREWS, CURRENT-CARRYING PARTS AND CONNECTIONS) |
- |
20 |
|
- |
| 26.3(SCREWS, CURRENT-CARRYING PARTS AND CONNECTIONS) |
- |
20 |
|
- |
| 26(SCREWS, CURRENT-CARRYING PARTS AND CONNECTIONS) |
- |
20 |
|
- |
| 25(RESISTANCE TO HEAT) |
- |
20 |
|
- |
| 24.18(MECHANICAL STRENGTH) |
- |
20 |
|
- |
| 24.17(MECHANICAL STRENGTH) |
- |
20 |
|
- |
| 24.16 & 24.14.2(MECHANICAL STRENGTH) |
- |
20 |
|
- |
| 24.16 & 24.14.1(MECHANICAL STRENGTH) |
- |
20 |
|
- |
| 24.15 & 24.14.2(MECHANICAL STRENGTH) |
- |
20 |
|
- |
| 24.15 & 24.14.1(MECHANICAL STRENGTH) |
- |
20 |
|
- |
| 24.14.2(MECHANICAL STRENGTH) |
- |
20 |
|
- |
| 24.14.1(MECHANICAL STRENGTH) |
- |
20 |
|
- |
| 24.14(MECHANICAL STRENGTH) |
- |
20 |
|
- |
| 24.13(MECHANICAL STRENGTH) |
- |
20 |
|
- |
| 24.12(MECHANICAL STRENGTH) |
- |
20 |
|
- |
| 24.11(MECHANICAL STRENGTH) |
- |
20 |
|
- |
| 24.1(MECHANICAL STRENGTH) |
- |
20 |
|
- |
| 24.9(MECHANICAL STRENGTH) |
- |
20 |
|
- |
| 24.8(MECHANICAL STRENGTH) |
- |
20 |
|
- |
| 24.7(MECHANICAL STRENGTH) |
- |
20 |
|
- |
| 24.6(MECHANICAL STRENGTH) |
- |
20 |
|
- |
| 24.5(MECHANICAL STRENGTH) |
- |
20 |
|
- |
| 24.4(MECHANICAL STRENGTH) |
- |
20 |
|
- |
| 24.3(MECHANICAL STRENGTH) |
- |
20 |
|
- |
| 24.2(MECHANICAL STRENGTH) |
- |
20 |
|
- |
| 24.1(MECHANICAL STRENGTH) |
- |
20 |
|
- |
| 24(MECHANICAL STRENGTH) |
- |
20 |
|
- |
| 23.4(FLEXIBLE CABLES AND THEIR CONNECTION) |
- |
20 |
|
- |
| 23.3(FLEXIBLE CABLES AND THEIR CONNECTION) |
- |
20 |
|
- |
| 23.2(FLEXIBLE CABLES AND THEIR CONNECTION) |
- |
20 |
|
- |
| 23.1(FLEXIBLE CABLES AND THEIR CONNECTION) |
- |
20 |
|
- |
| 23(FLEXIBLE CABLES AND THEIR CONNECTION) |
- |
20 |
|
- |
| 22(FORCE NECESSARY TO WITHDRAW THE PLUG) |
- |
20 |
|
- |
| 17.3(INSULATION RESISTANCE AND ELECTRIC STRENGTH) |
- |
100 |
|
- |
| 17.1.2(INSULATION RESISTANCE AND ELECTRIC STRENGTH) |
- |
100 |
|
- |
| 17.1.1(INSULATION RESISTANCE AND ELECTRIC STRENGTH) |
- |
100 |
|
- |
| 17(INSULATION RESISTANCE AND ELECTRIC STRENGTH) |
- |
100 |
|
- |
| 16.2.4(RESISTANCE TO AGEING, TO HARMFUL INGRESS OF WATER AND TO HUMIDITY) |
- |
100 |
|
- |
| 16.2.3(RESISTANCE TO AGEING, TO HARMFUL INGRESS OF WATER AND TO HUMIDITY) |
- |
100 |
|
- |
| 16.2.2(RESISTANCE TO AGEING, TO HARMFUL INGRESS OF WATER AND TO HUMIDITY) |
- |
100 |
|
- |
| 16.2.1(RESISTANCE TO AGEING, TO HARMFUL INGRESS OF WATER AND TO HUMIDITY) |
- |
100 |
|
- |
| 16(RESISTANCE TO AGEING, TO HARMFUL INGRESS OF WATER AND TO HUMIDITY) |
- |
100 |
|
- |
| 14.25(CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
20 |
|
- |
| 14.24(CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
20 |
|
- |
| 14.23.2(CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
20 |
|
- |
| 14.23.1(CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
20 |
|
- |
| 14.23(CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
20 |
|
- |
| 14.22(CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
20 |
|
- |
| 14.21(CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
20 |
|
- |
| 14.2(CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
20 |
|
- |
| 14.19(CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
20 |
|
- |
| 14.18(CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
20 |
|
- |
| 14.17(CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
20 |
|
- |
| 14.16(CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
20 |
|
- |
| 14.15(CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
20 |
|
- |
| 14.14(CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
20 |
|
- |
| 14.13(CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
20 |
|
- |
| 14.12(CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
20 |
|
- |
| 14.11(CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
20 |
|
- |
| 14.1(CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
20 |
|
- |
| 14.9(CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
20 |
|
- |
| 14.8(CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
20 |
|
- |
| 14.7(CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
20 |
|
- |
| 14.6(CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
20 |
|
- |
| 14.5(CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
20 |
|
- |
| 14.4(CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
20 |
|
- |
| 14.3(CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
20 |
|
- |
| 14.2(CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
20 |
|
- |
| 14.1(CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
20 |
|
- |
| 14(CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
20 |
|
- |
| 13.23(CONSTRUCTION OF FIXED SOCKETOUTLETS) |
- |
20 |
|
- |
| 13.22(CONSTRUCTION OF FIXED SOCKETOUTLETS) |
- |
20 |
|
- |
| 13.21(CONSTRUCTION OF FIXED SOCKETOUTLETS) |
- |
20 |
|
- |
| 13.2(CONSTRUCTION OF FIXED SOCKETOUTLETS) |
- |
20 |
|
- |
| 13.19(CONSTRUCTION OF FIXED SOCKETOUTLETS) |
- |
20 |
|
- |
| 13.18(CONSTRUCTION OF FIXED SOCKETOUTLETS) |
- |
20 |
|
- |
| 13.15(CONSTRUCTION OF FIXED SOCKETOUTLETS) |
- |
20 |
|
- |
| 13.13(CONSTRUCTION OF FIXED SOCKETOUTLETS) |
- |
20 |
|
- |
| 13.12(CONSTRUCTION OF FIXED SOCKETOUTLETS) |
- |
20 |
|
- |
| 13.11(CONSTRUCTION OF FIXED SOCKETOUTLETS) |
- |
20 |
|
- |
| 13.8(CONSTRUCTION OF FIXED SOCKETOUTLETS) |
- |
20 |
|
- |
| 13.7.3 (CONSTRUCTION OF FIXED SOCKETOUTLETS) |
- |
20 |
|
- |
| 13.7.2 (CONSTRUCTION OF FIXED SOCKETOUTLETS) |
- |
20 |
|
- |
| 13.7.1(CONSTRUCTION OF FIXED SOCKETOUTLETS) |
- |
20 |
|
- |
| 13.7(CONSTRUCTION OF FIXED SOCKETOUTLETS) |
- |
20 |
|
- |
| 13(CONSTRUCTION OF FIXED SOCKETOUTLETS) |
- |
20 |
|
- |
| 12.3.12 (TERMINALS) |
- |
20 |
|
- |
| 12.3.11 (b)(TERMINALS) |
- |
20 |
|
- |
| 12.3.11 (a)(TERMINALS) |
- |
20 |
|
- |
| 12.3.10(TERMINALS) |
- |
20 |
|
- |
| 12.3.9(TERMINALS) |
- |
20 |
|
- |
| 12.3.8(TERMINALS) |
- |
20 |
|
- |
| 12.3.7(TERMINALS) |
- |
20 |
|
- |
| 12.3.6(TERMINALS) |
- |
20 |
|
- |
| 12.3.5(TERMINALS) |
- |
20 |
|
- |
| 12.3.4(TERMINALS) |
- |
20 |
|
- |
| 12.3.3(TERMINALS) |
- |
20 |
|
- |
| 12.3.2(TERMINALS) |
- |
20 |
|
- |
| 12.3.1(TERMINALS) |
- |
20 |
|
- |
| 12.3(TERMINALS) |
- |
20 |
|
- |
| 12.2.8(TERMINALS) |
- |
20 |
|
- |
| 12.2.6(TERMINALS) |
- |
20 |
|
- |
| 12.2(TERMINALS) |
- |
20 |
|
- |
| 12.1.2(TERMINALS) |
- |
20 |
|
- |
| 12.1.1(TERMINALS) |
- |
20 |
|
- |
| 12(TERMINALS) |
- |
20 |
|
- |
| 11.4(PROVISION FOR EARTHING) |
- |
20 |
|
- |
| 11.3(PROVISION FOR EARTHING) |
- |
20 |
|
- |
| 11(PROVISION FOR EARTHING) |
- |
20 |
|
- |
| 10.7(PROTECTION AGAINST ELECTRIC SHOCK) |
- |
20 |
|
- |
| 10.4(PROTECTION AGAINST ELECTRIC SHOCK) |
- |
20 |
|
- |
| 10.2.2(PROTECTION AGAINST ELECTRIC SHOCK) |
- |
20 |
|
- |
| 10.2.1(PROTECTION AGAINST ELECTRIC SHOCK) |
- |
20 |
|
- |
| 10.2(PROTECTION AGAINST ELECTRIC SHOCK) |
- |
20 |
|
- |
| 10(PROTECTION AGAINST ELECTRIC SHOCK) |
- |
20 |
|
- |
| 9.3(CHECKING OF DIMENSIONS) |
- |
100 |
|
- |
| 9.2(CHECKING OF DIMENSIONS) |
- |
100 |
|
- |
| 9.1(CHECKING OF DIMENSIONS) |
- |
100 |
|
- |
| 8.8(MARKING) |
- |
20 |
|
- |
| 8.7(MARKING) |
- |
20 |
|
- |
| 8.6(MARKING) |
- |
20 |
|
- |
| 8.5(MARKING) |
- |
20 |
|
- |
| 8.4(MARKING) |
- |
20 |
|
- |
| 8.3(MARKING) |
- |
20 |
|
- |
| 8.2(MARKING) |
- |
20 |
|
- |
| 8.1(MARKING) |
- |
20 |
|
- |
| 7.3(CLASSIFICATION) |
- |
20 |
|
- |
| 7.2.5(CLASSIFICATION) |
- |
20 |
|
- |
| 7.2.4(CLASSIFICATION) |
- |
20 |
|
- |
| 7.2.3(CLASSIFICATION) |
- |
20 |
|
- |
| 7.2.2 (CLASSIFICATION) |
- |
20 |
|
- |
| 7.2.1(CLASSIFICATION) |
- |
20 |
|
- |
| 7.2(CLASSIFICATION) |
- |
20 |
|
- |
| 7.1.4(CLASSIFICATION) |
- |
20 |
|
- |
| 7.1.3 (CLASSIFICATION) |
- |
20 |
|
- |
| 7.1.2(CLASSIFICATION) |
- |
20 |
|
- |
| 7.1.1 (CLASSIFICATION) |
- |
20 |
|
- |
| 7.1(CLASSIFICATION) |
- |
20 |
|
- |
| 6.2(RATINGS) |
- |
20 |
|
- |
| 6.1(RATINGS) |
- |
20 |
|
- |
| 30(ADDITIONAL TESTS ON PINS PROVIDED WITH INSULATING SLEEVES) |
- |
100 |
|
- |
| 29(RESISTANCE TO RUSTING) |
- |
100 |
|
- |
| 28.2(RESISTANCE OF INSULATING MATERIAL TO ABNORMAL HEAT, TO FIRE AND TO TRACKING) |
- |
100 |
|
- |
| 28.1.1(RESISTANCE OF INSULATING MATERIAL TO ABNORMAL HEAT, TO FIRE AND TO TRACKING) |
- |
100 |
|
- |
| 28.1(RESISTANCE OF INSULATING MATERIAL TO ABNORMAL HEAT, TO FIRE AND TO TRACKING) |
- |
100 |
|
- |
| 28(RESISTANCE OF INSULATING MATERIAL TO ABNORMAL HEAT, TO FIRE AND TO TRACKING) |
- |
100 |
|
- |
| 27.3(CREEPAGE DISTANCES, CLEARANCES AND DISTANCES THROUGH SEALING COMPOUND) |
- |
100 |
|
- |
| 27.2(CREEPAGE DISTANCES, CLEARANCES AND DISTANCES THROUGH SEALING COMPOUND) |
- |
100 |
|
- |
| 27.1(CREEPAGE DISTANCES, CLEARANCES AND DISTANCES THROUGH SEALING COMPOUND) |
- |
20 |
|
- |
| 27(CREEPAGE DISTANCES, CLEARANCES AND DISTANCES THROUGH SEALING COMPOUND) |
- |
20 |
|
- |
| 26.7(SCREWS, CURRENT-CARRYING PARTS AND CONNECTIONS) |
- |
20 |
|
- |
| 26.6(SCREWS, CURRENT-CARRYING PARTS AND CONNECTIONS) |
- |
20 |
|
- |
| 26.5(SCREWS, CURRENT-CARRYING PARTS AND CONNECTIONS) |
- |
20 |
|
- |
| 26.4(SCREWS, CURRENT-CARRYING PARTS AND CONNECTIONS) |
- |
20 |
|
- |
| 26.3(SCREWS, CURRENT-CARRYING PARTS AND CONNECTIONS) |
- |
20 |
|
- |
| 26.2(SCREWS, CURRENT-CARRYING PARTS AND CONNECTIONS) |
- |
20 |
|
- |
| 26.1(SCREWS, CURRENT-CARRYING PARTS AND CONNECTIONS) |
- |
20 |
|
- |
| 26(SCREWS, CURRENT-CARRYING PARTS AND CONNECTIONS) |
- |
20 |
|
- |
| 25.4(RESISTANCE TO HEAT) |
- |
20 |
|
- |
| 25.3(RESISTANCE TO HEAT) |
- |
20 |
|
- |
| 25.2(RESISTANCE TO HEAT) |
- |
20 |
|
- |
| 25.1(RESISTANCE TO HEAT) |
- |
20 |
|
- |
| 25(RESISTANCE TO HEAT) |
- |
20 |
|
- |
| 24.16 & 24.14.2(MECHANICAL STRENGTH) |
- |
20 |
|
- |
| 24.16 & 24.14.1(MECHANICAL STRENGTH) |
- |
20 |
|
- |
| 24.15 & 24.14.1(MECHANICAL STRENGTH) |
- |
20 |
|
- |
| 24.14.2(MECHANICAL STRENGTH) |
- |
20 |
|
- |
| 24.14.1(MECHANICAL STRENGTH) |
- |
20 |
|
- |
| 24.14(MECHANICAL STRENGTH) |
- |
20 |
|
- |
| 24.8(MECHANICAL STRENGTH) |
- |
20 |
|
- |
| 24.6(MECHANICAL STRENGTH) |
- |
20 |
|
- |
| 24.3(MECHANICAL STRENGTH) |
- |
20 |
|
- |
| 24.1(MECHANICAL STRENGTH) |
- |
20 |
|
- |
| 24(MECHANICAL STRENGTH) |
- |
20 |
|
- |
| 23(FLEXIBLE CABLES AND THEIR CONNECTION) |
- |
20 |
|
- |
| 21(NORMAL OPERATION) |
- |
300 |
|
- |
| 20(MAKING AND BREAKING CAPACITY) |
- |
300 |
|
- |
| 19(TEMPERATURE RISE) |
- |
100 |
|
- |
| 18(OPERATION OF EARTHING CONTACTS) |
- |
100 |
|
- |
| 17.3(INSULATION RESISTANCE AND ELECTRIC STRENGTH) |
- |
100 |
|
- |
| 17.1.1(INSULATION RESISTANCE AND ELECTRIC STRENGTH) |
- |
100 |
|
- |
| 17(INSULATION RESISTANCE AND ELECTRIC STRENGTH) |
- |
100 |
|
- |
| 16.3(RESISTANCE TO AGEING, TO HARMFUL INGRESS OF WATER AND TO HUMIDITY) |
- |
100 |
|
- |
| 16.2.4(RESISTANCE TO AGEING, TO HARMFUL INGRESS OF WATER AND TO HUMIDITY) |
- |
100 |
|
- |
| 16.2.3(RESISTANCE TO AGEING, TO HARMFUL INGRESS OF WATER AND TO HUMIDITY) |
- |
100 |
|
- |
| 16.2.2(RESISTANCE TO AGEING, TO HARMFUL INGRESS OF WATER AND TO HUMIDITY) |
- |
100 |
|
- |
| 16(RESISTANCE TO AGEING, TO HARMFUL INGRESS OF WATER AND TO HUMIDITY) |
- |
20 |
|
- |
| 14.25(CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
20 |
|
- |
| 14.24(CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
20 |
|
- |
| 14.23.2(CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
20 |
|
- |
| 14.23.1(CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
20 |
|
- |
| 14.22(CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
20 |
|
- |
| 14.21(CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
20 |
|
- |
| 14.2(CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
20 |
|
- |
| 14.19(CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
20 |
|
- |
| 14.18(CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
20 |
|
- |
| 14.17(CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
20 |
|
- |
| 14.16(CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
20 |
|
- |
| 14.14(CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
20 |
|
- |
| 14.13(CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
20 |
|
- |
| 14.12(CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
20 |
|
- |
| 14.6(CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
20 |
|
- |
| 14.5(CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
20 |
|
- |
| 14.4(CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
20 |
|
- |
| 12.3.12 (TERMINALS) |
- |
20 |
|
- |
| 12.3.11 (b)(TERMINALS) |
- |
20 |
|
- |
| 12.3.11 (a)(TERMINALS) |
- |
20 |
|
- |
| 12.3.10(TERMINALS) |
- |
20 |
|
- |
| 12.3.9(TERMINALS) |
- |
20 |
|
- |
| 12.3.8(TERMINALS) |
- |
20 |
|
- |
| 12.3.7(TERMINALS) |
- |
20 |
|
- |
| 12.3.6(TERMINALS) |
- |
20 |
|
- |
| 12.3.5(TERMINALS) |
- |
20 |
|
- |
| 12.3.4(TERMINALS) |
- |
20 |
|
- |
| 12.3.3(TERMINALS) |
- |
20 |
|
- |
| 12.3.2(TERMINALS) |
- |
20 |
|
- |
| 12.3.1(TERMINALS) |
- |
20 |
|
- |
| 12.3(TERMINALS) |
- |
20 |
|
- |
| 12.2.11(TERMINALS) |
- |
20 |
|
- |
| 12.2.10(TERMINALS) |
- |
20 |
|
- |
| 12.2.9(TERMINALS) |
- |
20 |
|
- |
| 12.2.8(TERMINALS) |
- |
20 |
|
- |
| 12.2.7(TERMINALS) |
- |
20 |
|
- |
| 12.2.6(TERMINALS) |
- |
20 |
|
- |
| 12.2.5(TERMINALS) |
- |
20 |
|
- |
| 12.2.4(TERMINALS) |
- |
20 |
|
- |
| 12.2.3(TERMINALS) |
- |
20 |
|
- |
| 12.2.2(TERMINALS) |
- |
20 |
|
- |
| 12.2.1(TERMINALS) |
- |
20 |
|
- |
| 12.2(TERMINALS) |
- |
20 |
|
- |
| 12.1.2(TERMINALS) |
- |
20 |
|
- |
| 12(TERMINALS) |
- |
20 |
|
- |
| 11.5(PROVISION FOR EARTHING) |
- |
20 |
|
- |
| 11.4(PROVISION FOR EARTHING) |
- |
20 |
|
- |
| 11.3(PROVISION FOR EARTHING) |
- |
20 |
|
- |
| 11.2(PROVISION FOR EARTHING) |
- |
20 |
|
- |
| 11.1(PROVISION FOR EARTHING) |
- |
20 |
|
- |
| 11(PROVISION FOR EARTHING) |
- |
20 |
|
- |
| 10.7(PROTECTION AGAINST ELECTRIC SHOCK) |
- |
20 |
|
- |
| 10.6(PROTECTION AGAINST ELECTRIC SHOCK) |
- |
20 |
|
- |
| 10.5(PROTECTION AGAINST ELECTRIC SHOCK) |
- |
20 |
|
- |
| 10.3(PROTECTION AGAINST ELECTRIC SHOCK) |
- |
20 |
|
- |
| 10.2.2(PROTECTION AGAINST ELECTRIC SHOCK) |
- |
20 |
|
- |
| 10.2.1(PROTECTION AGAINST ELECTRIC SHOCK) |
- |
20 |
|
- |
| 10.2(PROTECTION AGAINST ELECTRIC SHOCK) |
- |
20 |
|
- |
| 10(PROTECTION AGAINST ELECTRIC SHOCK) |
- |
20 |
|
- |
| 9.3(CHECKING OF DIMENSIONS) |
- |
100 |
|
- |
| 9.2(CHECKING OF DIMENSIONS) |
- |
100 |
|
- |
| 9.1(CHECKING OF DIMENSIONS) |
- |
100 |
|
- |
| 8.8(MARKING) |
- |
20 |
|
- |
| 8.7(MARKING) |
- |
20 |
|
- |
| 8.6(MARKING) |
- |
20 |
|
- |
| 8.5(MARKING) |
- |
20 |
|
- |
| 8.4(MARKING) |
- |
20 |
|
- |
| 8.3(MARKING) |
- |
20 |
|
- |
| 8.2(MARKING) |
- |
20 |
|
- |
| 8.1(MARKING) |
- |
20 |
|
- |
| 7.3(CLASSIFICATION) |
- |
20 |
|
- |
| 7.2.5(CLASSIFICATION) |
- |
20 |
|
- |
| 7.2.4(CLASSIFICATION) |
- |
20 |
|
- |
| 7.2.3(CLASSIFICATION) |
- |
20 |
|
- |
| 7.2.2 (CLASSIFICATION) |
- |
20 |
|
- |
| 7.2.1(CLASSIFICATION) |
- |
20 |
|
- |
| 7.2(CLASSIFICATION) |
- |
20 |
|
- |
| 7.1.4(CLASSIFICATION) |
- |
20 |
|
- |
| 7.1.3 (CLASSIFICATION) |
- |
20 |
|
- |
| 7.1(CLASSIFICATION) |
- |
20 |
|
- |
| 7(CLASSIFICATION) |
- |
20 |
|
- |
| 6.2(RATINGS) |
- |
20 |
|
- |
| 6.1(RATINGS) |
- |
20 |
|
- |
| 6(RATINGS) |
- |
20 |
|
- |
|
- |
- - |
| 7739 |
Alpha Test House Private Limited, Delhi
| 8131026
| IS 366 (1991) |
Electric iron - Specification (Fourth Revision) |
- |
9800 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 7.0(Classification (as per Cl.6 of IS 302-2-3 and Cl.6.1 of IS 302-1)) |
- |
25 |
|
Testing charges |
| 7.0(Classification (as per Cl.6 of IS 302-2-3 and Cl.6.2 of IS 302-1)) |
- |
25 |
|
Testing charges |
| 9.0(Protection against access to live parts (as per Cl. 8 of IS 302-2-3 and IS 302-1)) |
- |
50 |
|
Testing charges |
| 9.0(Power input and current (as per Cl. 10 of IS 302-2-3 and IS 302-1)) |
- |
250 |
|
Testing charges |
| 9.0(Temperature Rise (as per Cl. 11 of IS 302-2-3 and IS 302-1)) |
- |
100 |
|
Testing charges |
| 9.0(Temperature Rise (as per Cl. 11 of IS 302-2-3 and IS 302-1)) |
- |
100 |
|
Testing charges |
| 9.0(Temperature Rise (as per Cl. 11 of IS 302-2-3 and IS 302-1)) |
- |
100 |
|
Testing charges |
| 9.0(Temperature Rise (as per Cl. 11 of IS 302-2-3 and IS 302-1)) |
- |
100 |
|
Testing charges |
| 9.0(Leakage current and Electric Strength at Operating Temperature (as per Cl. 13 of IS 302-2-3 and IS 302-1)) |
- |
200 |
|
Testing charges |
| 9.0(Leakage current and Electric Strength at Operating Temperature (as per Cl. 13 of IS 302-2-3 and IS 302-1)) |
- |
100 |
|
Testing charges |
| 9.0(Transient Overvoltage (as per of Cl. 14 of IS 302-2-3 and Table 6 of IS 302-1)) |
- |
250 |
|
Testing charges |
| 9.0(Moisture Resistance (as per of Cl.15 of IS 302-2-3 and IS 302-1)) |
- |
200 |
|
Testing charges |
| 9.0(Moisture Resistance (as per of Cl.15 of IS 302-2-3 and IS 302-1)) |
- |
200 |
|
Testing charges |
| 9.0(Abnormal Operation (as per of Cl.19 of IS 302-2-3 and IS 302-1) ) |
- |
250 |
|
Testing charges |
| 9.0(Abnormal Operation (as per of Cl.19 of IS 302-2-3 and IS 302-1) ) |
- |
250 |
|
Testing charges |
| 9.0(Abnormal Operation (as per of Cl.19 of IS 302-2-3 and IS 302-1) ) |
- |
100 |
|
Testing charges |
| 9.0(Abnormal Operation (as per of Cl.19 of IS 302-2-3 and IS 302-1) ) |
- |
100 |
|
Testing charges |
| 9.0(Staibilty and mechanical hazards (as per of Cl.20 of IS 302-2-3 and IS 302-1) ) |
- |
150 |
|
Testing charges |
| 9.0(Mechanical strength (as per of Cl.21 of IS 302-2-3 and IS 302-1) ) |
- |
200 |
|
Testing charges |
| 9.0(Construction (as per of Cl.22 of IS 302-2-3 and IS 302-1) ) |
- |
50 |
|
Testing charges |
| 9.0(Construction (as per of Cl.22 of IS 302-2-3 and IS 302-1) ) |
- |
50 |
|
Testing charges |
| 9.0(Construction (as per of Cl.22 of IS 302-2-3 and IS 302-1) ) |
- |
50 |
|
Testing charges |
| 9.0(Construction (as per of Cl.22 of IS 302-2-3 and IS 302-1) ) |
- |
50 |
|
Testing charges |
| 9.0(Construction (as per of Cl.22 of IS 302-2-3 and IS 302-1) ) |
- |
50 |
|
Testing charges |
| 9.0(Construction (as per of Cl.22 of IS 302-2-3 and IS 302-1) ) |
- |
50 |
|
Testing charges |
| 9.0(Construction (as per of Cl.22 of IS 302-2-3 and IS 302-1) ) |
- |
50 |
|
Testing charges |
| 9.0(Internal wiring (as per of Cl.23 of IS 302-2-3 and IS 302-1) ) |
- |
150 |
|
Testing charges |
| 9.0(Internal wiring (as per of Cl.23 of IS 302-2-3 and IS 302-1) ) |
- |
150 |
|
Testing charges |
| 9.0(Internal wiring (as per of Cl.23 of IS 302-2-3 and IS 302-1) ) |
- |
100 |
|
Testing charges |
| 9.0(Internal wiring (as per of Cl.23 of IS 302-2-3 and IS 302-1) ) |
- |
100 |
|
Testing charges |
| 9.0(Components (as per of Cl.24 of IS 302-2-3 and IS 302-1) ) |
- |
250 |
|
Testing charges |
| 9.0(Supply connection and external flexible cord (as per of Cl.25 of IS 302-2-3 and IS 302-1) ) |
- |
150 |
|
Testing charges |
| 9.0(Supply connection and external flexible cord (as per of Cl.25 of IS 302-2-3 and IS 302-1) ) |
- |
150 |
|
Testing charges |
| 9.0(Supply connection and external flexible cord (as per of Cl.25 of IS 302-2-3 and IS 302-1) ) |
- |
150 |
|
Testing charges |
| 9.0(Supply connection and external flexible cord (as per of Cl.25 of IS 302-2-3 and IS 302-1) ) |
- |
100 |
|
Testing charges |
| 9.0(Supply connection and external flexible cord (as per of Cl.25 of IS 302-2-3 and IS 302-1) ) |
- |
100 |
|
Testing charges |
| 9.0(Terminals for external conductors (as per of Cl.26 of IS 302-2-3 and IS 302-1) ) |
- |
200 |
|
Testing charges |
| 9.0(Provision for earthing (as per of Cl.27 of IS 302-2-3 and IS 302-1) ) |
- |
50 |
|
Testing charges |
| 9.0(Provision for earthing (as per of Cl.27 of IS 302-2-3 and IS 302-1) ) |
- |
50 |
|
Testing charges |
| 9.0(Provision for earthing (as per of Cl.27 of IS 302-2-3 and IS 302-1) ) |
- |
50 |
|
Testing charges |
| 9.0(Provision for earthing (as per of Cl.27 of IS 302-2-3 and IS 302-1) ) |
- |
200 |
|
Testing charges |
| 9.0(Screw and connections (as per of Cl.28 of IS 302-2-3 and IS 302-1)) |
- |
150 |
|
Testing charges |
| 9.0(Screw and connections (as per of Cl.28 of IS 302-2-3 and IS 302-1)) |
- |
150 |
|
Testing charges |
| 9.0(Clearances, creepage distances and solid insulation (as per of Cl.29 of IS 302-2-3 and IS 302-1)) |
- |
200 |
|
Testing charges |
| 9.0(Clearances, creepage distances and solid insulation (as per of Cl.29 of IS 302-2-3 and IS 302-1)) |
- |
150 |
|
Testing charges |
| 9.0(Resistance to Heat and Fire (as per of Cl.30 of IS 302-2-3 and IS 302-1)) |
- |
250 |
|
Testing charges |
| 9.0(Resistance to Rusting (as per of Cl.31 of IS 302-2-3 and IS 302-1)) |
- |
250 |
|
Testing charges |
| 10.0(Measurement of Heating up time) |
- |
150 |
|
Testing charges |
| 10.0(Measurement of Heating up time) |
- |
150 |
|
Testing charges |
| 11.0(Measurement of sole plate temperature) |
- |
100 |
|
Testing charges |
| 11.0(Measurement of sole plate temperature) |
- |
100 |
|
Testing charges |
| 11.0(Measurement of sole plate temperature) |
- |
100 |
|
Testing charges |
| 11.0(Measurement of sole plate temperature) |
- |
100 |
|
Testing charges |
| 13.0(Measurement of Initial overswing temperature and Heating up excess temperature) |
- |
750 |
|
Testing charges |
| 13.0(Measurement of Initial overswing temperature and Heating up excess temperature) |
- |
400 |
|
Testing charges |
| 14.0(Measurement of Cyclic fluctuation of temperature of hottest point ) |
- |
500 |
|
Testing charges |
| 16.0(Measurement of Thermostatic staibility) |
- |
250 |
|
Testing charges |
| 16.0(Measurement of Thermostatic staibility) |
- |
250 |
|
Testing charges |
| 16.0(Measurement of Thermostatic staibility) |
- |
350 |
|
Testing charges |
| 16.0(Measurement of Thermostatic staibility) |
- |
150 |
|
Testing charges |
| 16.0(Measurement of Thermostatic staibility) |
- |
150 |
|
Testing charges |
| 16.0(Measurement of Thermostatic staibility) |
- |
150 |
|
Testing charges |
|
- |
- Restricted to dry iron only |
| 7740 |
Alpha Test House Private Limited, Delhi
| 8131026
| IS 8978 (1992) |
Specification for electric instantaneous water heaters (Second Revision) |
- |
15000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl.7 of IS 302-2-35:2017(Marking) |
- |
100 |
|
Test |
| Cl.8 of IS 302-2-35:2017(Protection Against Access To Live Parts) |
- |
350 |
|
Test |
| Cl.10 of IS 302-2- 35:2011(Power Input & Current ) |
- |
500 |
|
Test |
| Cl.11 of 302-2-35:2017(Heating) |
- |
650 |
|
Test |
| Cl.13 of IS 302-2-35:2017(Leakage Current & Electrical Strength at Operating Temperature ) |
- |
700 |
|
Test |
| Cl.14 of IS 302-2-35:2017(Transient Over Voltages ) |
- |
700 |
|
Test |
| Cl.15 of IS 302-2-35-2011(Moisture Resistance ) |
- |
700 |
|
Test |
| Cl.16 of IS 302-2-Â35:2011(Leakage Current and Electric Strength) |
- |
700 |
|
Test |
| Cl.17 IS 302-2-35:2017(Overload Protection of Transformers & Associated circuits ) |
- |
350 |
|
Test |
| Cl.19 of IS 302-2-35:2017(Abnormal Operation) |
- |
700 |
|
Test |
| Cl.20 of IS 302-2-35-2011(Stability & Mechanical Hazards
) |
- |
500 |
|
Test |
| Cl.21.1 of IS 302-2-35-2011(Mechanical strength) |
- |
500 |
|
Test |
| Cl.22 of IS 302-2-35-2011(Construction
) |
- |
400 |
|
Test |
| Cl.23 of IS 302-2-35-2011(Internal Wiring) |
- |
500 |
|
Test |
| Cl.24 of IS 302-2-35:2017(Component
) |
- |
400 |
|
Test |
| Cl.25 of IS 302-2-35:2017(Supply Connection & External Flexible Cords) |
- |
300 |
|
Test |
| Cl.26 of IS 302-2-35:2017(Terminals for External Conductors) |
- |
500 |
|
Test |
| Cl.27 of IS 302-2-35:2017(Provision for Earthing) |
- |
700 |
|
Test |
| Cl.28 of IS 302-2-35:2017(Screws and Connections
) |
- |
300 |
|
Test |
| Cl.29 of IS 302-2-35:2017(Clearances, Creepage Distances and Solid Insulation) |
- |
400 |
|
Test |
| Cl.30 of IS 302-2-35: 2011(Resistance to Heat and Fire) |
- |
600 |
|
Test |
| Cl.31 of IS 302-2-35: 2011(Resistance to Rusting
) |
- |
400 |
|
Test |
| Cl.11 of IS 8978 : 1992(Operation of flow switch) |
- |
600 |
|
Test |
| Cl.7 of IS 302-2-35:2017(Marking) |
- |
0 |
|
Test |
| Cl.7 of IS 302-2-35:2017(Marking) |
- |
0 |
|
Test |
| Cl.7 of IS 302-2-35:2017(Marking) |
- |
0 |
|
Test |
| Cl.7 of IS 302-2-35:2017(Marking) |
- |
0 |
|
Test |
| Cl.7 of IS 302-2-35:2017(Marking) |
- |
0 |
|
Test |
| Cl.7 of IS 302-2-35:2017(Marking) |
- |
0 |
|
Test |
| Cl.7 of IS 302-2-35:2017(Marking) |
- |
0 |
|
Test |
| Cl.7 of IS 302-2-35:2017(Marking) |
- |
0 |
|
Test |
| Cl.7 of IS 302-2-35:2017(Marking) |
- |
0 |
|
Test |
| Cl.7 of IS 302-2-35:2017(Marking) |
- |
0 |
|
Test |
| Cl.7 of IS 302-2-35:2017(Marking) |
- |
0 |
|
Test |
| Cl.7 of IS 302-2-35:2017(Marking) |
- |
0 |
|
Test |
| Cl.7 of IS 302-2-35:2017(Marking) |
- |
0 |
|
Test |
| Cl.7 of IS 302-2-35:2017(Marking) |
- |
0 |
|
Test |
| Cl.7 of IS 302-2-35:2017(Marking) |
- |
0 |
|
Test |
| Cl.7 of IS 302-2-35:2017(Marking) |
- |
0 |
|
Test |
| Cl.7 of IS 302-2-35:2017(Marking) |
- |
0 |
|
Test |
| Cl.7 of IS 302-2-35:2017(Marking) |
- |
0 |
|
Test |
| Cl.7 of IS 302-2-35:2017(Marking) |
- |
0 |
|
Test |
| Cl.7 of IS 302-2-35:2017(Marking) |
- |
0 |
|
Test |
| Cl.7 of IS 302-2-35:2017(Marking) |
- |
0 |
|
Test |
| Cl.7 of IS 302-2-35:2017(Marking) |
- |
0 |
|
Test |
| Cl.7 of IS 302-2-35:2017(Marking) |
- |
0 |
|
Test |
| Cl.7 of IS 302-2-35:2017(Marking) |
- |
0 |
|
Test |
| Cl.6 of IS 302-2-35:2017(Classification) |
- |
0 |
|
Test |
| Cl.6 of IS 302-2-35:2017(Classification) |
- |
0 |
|
Test |
| Cl.11 of 302-2-35:2017(Heating) |
- |
0 |
|
Test |
| Cl.11 of 302-2-35:2017(Heating) |
- |
0 |
|
Test |
| Cl.11 of 302-2-35:2017(Heating) |
- |
0 |
|
Test |
| Cl.13 of IS 302-2-35:2017(Leakage Current & Electrical Strength at Operating Temperature ) |
- |
0 |
|
Test |
| Cl.15 of IS 302-2-35-2011(Moisture Resistance ) |
- |
0 |
|
Test |
| Cl.16 of IS 302-2-Â35:2011(Leakage Current and Electric Strength) |
- |
0 |
|
Test |
| Cl.19 of IS 302-2-35:2017(Abnormal Operation) |
- |
0 |
|
Test |
| Cl.19 of IS 302-2-35:2017(Abnormal Operation) |
- |
0 |
|
Test |
| Cl.19 of IS 302-2-35:2017(Abnormal Operation) |
- |
0 |
|
Test |
| Cl.19 of IS 302-2-35:2017(Abnormal Operation) |
- |
0 |
|
Test |
| Cl. 21.2 of IS 302-1:2008(Mechanical strength) |
- |
0 |
|
Test |
| Cl.22 of IS 302-2-35-2011(Construction
) |
- |
0 |
|
Test |
| Cl.22 of IS 302-2-35-2011(Construction
) |
- |
0 |
|
Test |
| Cl.22 of IS 302-2-35-2011(Construction
) |
- |
0 |
|
Test |
| Cl.22 of IS 302-2-35-2011(Construction
) |
- |
0 |
|
Test |
| Cl.22 of IS 302-2-35-2011(Construction
) |
- |
0 |
|
Test |
| Cl.22 of IS 302-2-35-2011(Construction
) |
- |
0 |
|
Test |
| Cl.22 of IS 302-2-35-2011(Construction
) |
- |
0 |
|
Test |
| Cl.22 of IS 302-2-35-2011(Construction
) |
- |
0 |
|
Test |
| Cl.22 of IS 302-2-35-2011(Construction
) |
- |
0 |
|
Test |
| Cl.22 of IS 302-2-35-2011(Construction
) |
- |
0 |
|
Test |
| Cl.22 of IS 302-2-35-2011(Construction
) |
- |
0 |
|
Test |
| Cl.22 of IS 302-2-35-2011(Construction
) |
- |
0 |
|
Test |
| Cl.22 of IS 302-2-35-2011(Construction
) |
- |
0 |
|
Test |
| Cl.22 of IS 302-2-35-2011(Construction
) |
- |
0 |
|
Test |
| Cl.22 of IS 302-2-35-2011(Construction
) |
- |
0 |
|
Test |
| Cl.22 of IS 302-2-35-2011(Construction
) |
- |
0 |
|
Test |
| Cl.22 of IS 302-2-35-2011(Construction
) |
- |
0 |
|
Test |
| Cl.22 of IS 302-2-35-2011(Construction
) |
- |
0 |
|
Test |
| Cl.22 of IS 302-2-35-2011(Construction
) |
- |
0 |
|
Test |
| Cl.22 of IS 302-2-35-2011(Construction
) |
- |
0 |
|
Test |
| Cl.22 of IS 302-2-35-2011(Construction
) |
- |
0 |
|
Test |
| Cl.22 of IS 302-2-35-2011(Construction
) |
- |
0 |
|
Test |
| Cl.22 of IS 302-2-35-2011(Construction
) |
- |
0 |
|
Test |
| Cl.22 of IS 302-2-35-2011(Construction
) |
- |
0 |
|
Test |
| Cl.22 of IS 302-2-35-2011(Construction
) |
- |
0 |
|
Test |
| Cl.22 of IS 302-2-35-2011(Construction
) |
- |
0 |
|
Test |
| Cl.22 of IS 302-2-35-2011(Construction
) |
- |
0 |
|
Test |
| Cl.22 of IS 302-2-35-2011(Construction
) |
- |
0 |
|
Test |
| Cl.22 of IS 302-2-35-2011(Construction
) |
- |
0 |
|
Test |
| Cl.22 of IS 302-2-35-2011(Construction
) |
- |
0 |
|
Test |
| Cl.22 of IS 302-2-35-2011(Construction
) |
- |
0 |
|
Test |
| Cl.22 of IS 302-2-35-2011(Construction
) |
- |
0 |
|
Test |
| Cl.22 of IS 302-2-35-2011(Construction
) |
- |
0 |
|
Test |
| Cl.22 of IS 302-2-35-2011(Construction
) |
- |
0 |
|
Test |
| Cl.22 of IS 302-2-35-2011(Construction
) |
- |
0 |
|
Test |
| Cl.22 of IS 302-2-35-2011(Construction
) |
- |
0 |
|
Test |
| Cl.22 of IS 302-2-35-2011(Construction
) |
- |
0 |
|
Test |
| Cl.22 of IS 302-2-35-2011(Construction
) |
- |
0 |
|
Test |
| Cl.22 of IS 302-2-35-2011(Construction
) |
- |
0 |
|
Test |
| Cl.22 of IS 302-2-35-2011(Construction
) |
- |
0 |
|
Test |
| Cl.22 of IS 302-2-35-2011(Construction
) |
- |
0 |
|
Test |
| Cl.22 of IS 302-2-35-2011(Construction
) |
- |
0 |
|
Test |
| Cl.22 of IS 302-2-35-2011(Construction
) |
- |
0 |
|
Test |
| Cl.22 of IS 302-2-35-2011(Construction
) |
- |
0 |
|
Test |
| Cl.22 of IS 302-2-35-2011(Construction
) |
- |
0 |
|
Test |
| Cl.22 of IS 302-2-35-2011(Construction
) |
- |
0 |
|
Test |
| Cl.22 of IS 302-2-35-2011(Construction
) |
- |
0 |
|
Test |
| Cl.22 of IS 302-2-35-2011(Construction
) |
- |
0 |
|
Test |
| Cl.22 of IS 302-2-35-2011(Construction
) |
- |
0 |
|
Test |
| Cl.22 of IS 302-2-35-2011(Construction
) |
- |
0 |
|
Test |
| Cl.22 of IS 302-2-35-2011(Construction
) |
- |
0 |
|
Test |
| Cl.22 of IS 302-2-35-2011(Construction
) |
- |
0 |
|
Test |
| Cl.22 of IS 302-2-35-2011(Construction
) |
- |
0 |
|
Test |
| Cl.23 of IS 302-2-35-2011(Internal Wiring) |
- |
0 |
|
Test |
| Cl.23 of IS 302-2-35-2011(Internal Wiring) |
- |
0 |
|
Test |
| Cl.23 of IS 302-2-35-2011(Internal Wiring) |
- |
0 |
|
Test |
| Cl.23 of IS 302-2-35-2011(Internal Wiring) |
- |
0 |
|
Test |
| Cl.23 of IS 302-2-35-2011(Internal Wiring) |
- |
0 |
|
Test |
| Cl.23 of IS 302-2-35-2011(Internal Wiring) |
- |
0 |
|
Test |
| Cl.23 of IS 302-2-35-2011(Internal Wiring) |
- |
0 |
|
Test |
| Cl.23 of IS 302-2-35-2011(Internal Wiring) |
- |
0 |
|
Test |
| Cl.23 of IS 302-2-35-2011(Internal Wiring) |
- |
0 |
|
Test |
| Cl.23 of IS 302-2-35-2011(Internal Wiring) |
- |
0 |
|
Test |
| Cl.23 of IS 302-2-35-2011(Internal Wiring) |
- |
0 |
|
Test |
| Cl.23 of IS 302-2-35-2011(Internal Wiring) |
- |
0 |
|
Test |
| Cl.23 of IS 302-2-35-2011(Internal Wiring) |
- |
0 |
|
Test |
| Cl.24 of IS 302-2-35:2017(Component
) |
- |
0 |
|
Test |
| Cl.24 of IS 302-2-35:2017(Component
) |
- |
0 |
|
Test |
| Cl.24 of IS 302-2-35:2017(Component
) |
- |
0 |
|
Test |
| Cl.24 of IS 302-2-35:2017(Component
) |
- |
0 |
|
Test |
| Cl.25 of IS 302-2-35:2017(Supply Connection & External Flexible Cords) |
- |
0 |
|
Test |
| Cl.25 of IS 302-2-35:2017(Supply Connection & External Flexible Cords) |
- |
0 |
|
Test |
| Cl.25 of IS 302-2-35:2017(Supply Connection & External Flexible Cords) |
- |
0 |
|
Test |
| Cl.25 of IS 302-2-35:2017(Supply Connection & External Flexible Cords) |
- |
0 |
|
Test |
| Cl.25 of IS 302-2-35:2017(Supply Connection & External Flexible Cords) |
- |
10 |
|
Test |
| Cl.25 of IS 302-2-35:2017(Supply Connection & External Flexible Cords) |
- |
0 |
|
Test |
| Cl.25 of IS 302-2-35:2017(Supply Connection & External Flexible Cords) |
- |
0 |
|
Test |
| Cl.25 of IS 302-2-35:2017(Supply Connection & External Flexible Cords) |
- |
0 |
|
Test |
| Cl.25 of IS 302-2-35:2017(Supply Connection & External Flexible Cords) |
- |
0 |
|
Test |
| Cl.25 of IS 302-2-35:2017(Supply Connection & External Flexible Cords) |
- |
0 |
|
Test |
| Cl.25 of IS 302-2-35:2017(Supply Connection & External Flexible Cords) |
- |
0 |
|
Test |
| Cl.25 of IS 302-2-35:2017(Supply Connection & External Flexible Cords) |
- |
0 |
|
Test |
| Cl.25 of IS 302-2-35:2017(Supply Connection & External Flexible Cords) |
- |
0 |
|
Test |
| Cl.25 of IS 302-2-35:2017(Supply Connection & External Flexible Cords) |
- |
0 |
|
Test |
| Cl.25 of IS 302-2-35:2017(Supply Connection & External Flexible Cords) |
- |
0 |
|
Test |
| Cl.25 of IS 302-2-35:2017(Supply Connection & External Flexible Cords) |
- |
0 |
|
Test |
| Cl.25 of IS 302-2-35:2017(Supply Connection & External Flexible Cords) |
- |
0 |
|
Test |
| Cl.25 of IS 302-2-35:2017(Supply Connection & External Flexible Cords) |
- |
0 |
|
Test |
| Cl.25 of IS 302-2-35:2017(Supply Connection & External Flexible Cords) |
- |
0 |
|
Test |
| Cl.25 of IS 302-2-35:2017(Supply Connection & External Flexible Cords) |
- |
0 |
|
Test |
| Cl.25 of IS 302-2-35:2017(Supply Connection & External Flexible Cords) |
- |
0 |
|
Test |
| Cl.25 of IS 302-2-35:2017(Supply Connection & External Flexible Cords) |
- |
0 |
|
Test |
| Cl.25 of IS 302-2-35:2017(Supply Connection & External Flexible Cords) |
- |
0 |
|
Test |
| Cl.25 of IS 302-2-35:2017(Supply Connection & External Flexible Cords) |
- |
0 |
|
Test |
| Cl.25 of IS 302-2-35:2017(Supply Connection & External Flexible Cords) |
- |
0 |
|
Test |
| Cl.26 of IS 302-2-35:2017(Terminals for External Conductors) |
- |
0 |
|
Test |
| Cl.26 of IS 302-2-35:2017(Terminals for External Conductors) |
- |
0 |
|
Test |
| Cl.26 of IS 302-2-35:2017(Terminals for External Conductors) |
- |
0 |
|
Test |
| Cl.26 of IS 302-2-35:2017(Terminals for External Conductors) |
- |
0 |
|
Test |
| Cl.26 of IS 302-2-35:2017(Terminals for External Conductors) |
- |
0 |
|
Test |
| Cl.26 of IS 302-2-35:2017(Terminals for External Conductors) |
- |
0 |
|
Test |
| Cl.26 of IS 302-2-35:2017(Terminals for External Conductors) |
- |
0 |
|
Test |
| Cl.26 of IS 302-2-35:2017(Terminals for External Conductors) |
- |
0 |
|
Test |
| Cl.26 of IS 302-2-35:2017(Terminals for External Conductors) |
- |
0 |
|
Test |
| Cl.27 of IS 302-2-35:2017(Provision for Earthing) |
- |
0 |
|
Test |
| Cl.27 of IS 302-2-35:2017(Provision for Earthing) |
- |
0 |
|
Test |
| Cl.27 of IS 302-2-35:2017(Provision for Earthing) |
- |
0 |
|
Test |
| Cl.27 of IS 302-2-35:2017(Provision for Earthing) |
- |
0 |
|
Test |
| Cl.27 of IS 302-2-35:2017(Provision for Earthing) |
- |
0 |
|
Test |
| Cl.27 of IS 302-2-35:2017(Provision for Earthing) |
- |
0 |
|
Test |
| Cl.29 of IS 302-2-35:2017(Clearances, Creepage Distances and Solid Insulation) |
- |
0 |
|
Test |
| Cl.29 of IS 302-2-35:2017(Clearances, Creepage Distances and Solid Insulation) |
- |
0 |
|
Test |
| Cl.30 of IS 302-2-35: 2011(Resistance to Heat and Fire) |
- |
0 |
|
Test |
| Cl.32 of IS 302-2-35: 2011(Radiation, Toxicity and Similar Hazards
) |
- |
40 |
|
Test |
| Cl.10 of IS 8978 : 1992(Finish) |
- |
10 |
|
Test |
| Cl.12 of IS 8978 : 1992(Endurance) |
- |
500 |
|
Test |
| Cl.12 of IS 8978 : 1992(Endurance) |
- |
10 |
|
Test |
| Cl.10 of IS 8978 : 1992(Finish) |
- |
10 |
|
Test |
| Cl.31 of IS 302-2-35: 2017(Resistance to Rusting
) |
- |
10 |
|
Test |
| Cl.30.2 of IS 302-1:2008(Resistance to Heat and Fire) |
- |
10 |
|
Test |
| Cl.30.1 of IS 302-1:2008(Resistance to Heat and Fire) |
- |
10 |
|
Test |
| Cl.29.2 of IS 302-2-35:2017(Clearances, Creepage Distances and Solid Insulation : Creepage distance ) |
- |
10 |
|
Test |
| Cl.29.1 of IS 302-2-35:2017(Clearances, Creepage Distances and Solid Insulation : Clearance distance ) |
- |
10 |
|
Test |
| Cl.28 of IS 302-2-35:2017(Screws and Connections
) |
- |
10 |
|
Test |
| Cl.27.5 of IS 302-2-35:2017(Provision for Earthing : ECR ) |
- |
10 |
|
Test |
| Cl.27 of IS 302-2-35:2017(Provision for Earthing) |
- |
10 |
|
Test |
| Cl.26 of IS 302-2-35:2017(Terminals for External Conductors) |
- |
10 |
|
Test |
| Cl.25.18 of IS 302-2-35:2017(Supply Connection & External Flexible Cords) |
- |
10 |
|
Test |
| Cl.25.15 of IS 302-2-35:2017(Supply Connection & External Flexible Cords : Cord grip test - displacement ) |
- |
10 |
|
Test |
| Cl.25.15 of IS 302-2-35:2017(Supply Connection & External Flexible Cords : Cord grip test ) |
- |
10 |
|
Test |
| Cl.25.12 of IS 302-2-35:2017(Supply Connection & External Flexible Cords : Moulding of supply cord ) |
- |
10 |
|
Test |
| Cl.25.10 of IS 302-2-35:2017(Supply Connection & External Flexible Cords : Colour of Earthing conductor ) |
- |
10 |
|
Test |
| Cl.25.8 of IS 302-2-35:2017(Supply Connection & External Flexible Cords : Resistance of supply cord ) |
- |
10 |
|
Test |
| Cl.25.5 of IS 302-2-35:2017(Supply Connection & External Flexible Cords : Type of attachment ) |
- |
10 |
|
Test |
| Cl.25.1 of IS 302-2-35:2017(Supply Connection & External Flexible Cords : connection to the supply mains) |
- |
10 |
|
Test |
| Cl.25 of IS 302-2-35:2017(Supply Connection & External Flexible Cords) |
- |
10 |
|
Test |
| Cl.24 of IS 302-2-35:2017(Component
) |
- |
10 |
|
Test |
| Cl.23 of IS 302-2-35:2017(Internal Wiring ; Colour of earthing conductor) |
- |
10 |
|
Test |
| Cl.23 of IS 302-2-35:2017(Internal Wiring) |
- |
10 |
|
Test |
| Cl.22.110 of IS 302-2-35:2017(Construction : Provision for fixing to wall
) |
- |
10 |
|
Test |
| Cl.22.109 of IS 302-2-35:2017(Construction : Operation of presure switch of open outlet water heater
) |
- |
10 |
|
Test |
| Cl.22.108 of IS 302-2-35:2017(Construction : Temperature of outlet water intended to supply for showring
) |
- |
10 |
|
Test |
| Cl.22.107 of IS 302-2-35:2017(Construction : Temperature of outlet
) |
- |
10 |
|
Test |
| Cl.22.106 of IS 302-2-35:2017(Construction : Operation of thermal cut out for closed water heater
) |
- |
10 |
|
Test |
| Cl.22.104 of IS 302-2-35:2017(Construction : Pressure in open outlet water heaters
) |
- |
10 |
|
Test |
| Cl.22.103 of IS 302-2-35:2017(Construction : Pressure relief device operation for closed water heater
) |
- |
10 |
|
Test |
| Cl.22.102 of IS 302-2-35:2017(Construction : excessive temperature of outlet
) |
- |
10 |
|
Test |
| Cl.22.101 of IS 302-2-35:2017(Construction : Rated pressure of closed water heater
) |
- |
10 |
|
Test |
| Cl.22.47 of IS 302-2-35:2017(Construction : Water pressure test
) |
- |
10 |
|
Test |
| Cl.22.44 of IS 302-1:2008(Construction : Shape and decoration
) |
- |
10 |
|
Test |
| Cl.22.34, Cl 22.35 of
IS 302-1:2008(Construction : Shaft of operating Knobs ) |
- |
10 |
|
Test |
| Cl.22.33 of
IS 302-1:2008(Construction : Direct contact of liquids ) |
- |
10 |
|
Test |
| Cl 22.26 ,Cl.22.28, Cl 22.29, Cl 22.30 , Cl 22.31, Cl 22.32 of
IS 302-1:2008(Construction : Supplymentry/ double / reinforced insulation for Class II/ Class III appliance ) |
- |
10 |
|
Test |
| Cl.22.18 of IS 302-1:2008(Construction : Resistance to corrosion
) |
- |
10 |
|
Test |
| Cl.22.17 of IS 302-1:2008(Construction : Spacers
) |
- |
10 |
|
Test |
| Cl.22.14 of IS 302-1:2008(Construction : Ragged or sharp edges
) |
- |
10 |
|
Test |
| Cl.22.12 of IS 302-1:2008(Construction : Fixing of Handle, knob, grips, levers and similar parts
) |
- |
10 |
|
Test |
| Cl.22.11 of IS 302-1:2008(Construction : Fixing of non detachable parts
) |
- |
10 |
|
Test |
| Cl.22.7 of IS 302-1:2008(Construction : safeguards against the risk of excessive pressure.
) |
- |
10 |
|
Test |
| Cl.22.6 of IS 302-2-35:2017(Construction : size of drain hole
) |
- |
10 |
|
Test |
| Cl.22.6 of IS 302-1:2008(Construction : effect of water on 3 insulation
) |
- |
10 |
|
Test |
| Cl.22.2 of IS 302-1:2008(Construction : connection to supply mains
) |
- |
10 |
|
Test |
| Cl.22.1 of IS 302-1:2008(Construction : IP test
) |
- |
10 |
|
Test |
| Cl. 21.2 of IS 302-1:2008(Mechanical strength : prevent penetration by sharp implements. ) |
- |
10 |
|
Test |
| Cl.21.1 of IS 302-1:2008(Mechanical strength : Rough handling in normal use) |
- |
10 |
|
Test |
| Cl.20 of IS 302-2-35:2017(Stability & Mechanical Hazards
) |
- |
10 |
|
Test |
| Cl.19 of IS 302-2-35:2017(Abnormal Operation : effect on container) |
- |
10 |
|
Test |
| Cl.19 of IS 302-2-35:2017(Abnormal Operation : High voltage) |
- |
10 |
|
Test |
| Cl.19 of IS 302-2-35:2017(Abnormal Operation : Temperature rise of insulation of supply cord) |
- |
10 |
|
Test |
| Cl.19 of IS 302-2-35:2017(Abnormal Operation : Temperature rise of test corner) |
- |
10 |
|
Test |
| Cl.19 of IS 302-2-35:2017(Abnormal Operation : Emission of flames, molten metal ,or poisonous or ignitable gas) |
- |
10 |
|
Test |
| Cl.16 of IS 302-2-Â35:2017(Leakage Current and Electric Strength (After Humidity)) |
- |
10 |
|
Test |
| Cl.16 of IS 302-2-Â35:2017(Leakage Current and Electric Strength (After Humidity)) |
- |
10 |
|
Test |
| Cl.15 of IS 302-2-35:2017(Moisture Resistance ) |
- |
10 |
|
Test |
| Cl.14 of IS 302-2-35:2017(Transient Over Voltages ) |
- |
10 |
|
Test |
| Cl.13 of IS 302-2-35:2017(Leakage Current & 3 Strength at Operating Temperature : High voltage ) |
- |
10 |
|
Test |
| Cl.13 of IS 302-2-35:2017(Leakage Current & 3 Strength at Operating Temperature ) |
- |
10 |
|
Test |
| Cl.11 of 302-2-35:2017(Heating : room temperature) |
- |
10 |
|
Test |
| Cl.11 of 302-2-35:2017(Heating : Insulation of supply cord) |
- |
10 |
|
Test |
| Cl.11 of 302-2-35:2017(Heating : Temperature rise of test corner) |
- |
10 |
|
Test |
| Cl.10 of IS 302-2- 35:2017(Power Input & Current ) |
- |
10 |
|
Test |
| Cl.8 of IS 302-2-35:2017(Protection Against Access To Live Parts) |
- |
10 |
|
Test |
| Cl.7.102 of IS 302-2-35:2017(Marking : Standard mark) |
- |
10 |
|
Test |
| Cl.7.101 of IS 302-2-35:2017(Marking : Woter inlet and outlet idetification) |
- |
10 |
|
Test |
| Cl.7.15 of IS 302-1:2008(Marking : Position of marking) |
- |
10 |
|
Test |
| Cl.7.14 of IS 302-1:2008(Marking ; Legibility and durability) |
- |
10 |
|
Test |
| Cl.7.13 of IS 302-1:2008(Marking : Language) |
- |
10 |
|
Test |
| Cl.7.10 & 7.11 of IS 302-1:2008(Marking : Indication for direction of control) |
- |
10 |
|
Test |
| Cl.7.8 of IS 302-1:2008(Marking : Terminal for connection ) |
- |
10 |
|
Test |
| Cl.7.6 of IS 302-1:2008(Marking : Symbols) |
- |
10 |
|
Test |
| Cl.7.1 of IS 302-2-35:2017(Marking : rated pressure) |
- |
10 |
|
Test |
| Cl.7.1 of IS 302-1:2008(Marking : Country of manufacture) |
- |
10 |
|
Test |
| Cl.7.1 of IS 302-1:2008(Marking : IP number ) |
- |
10 |
|
Test |
| Cl.7.1 of IS 302-1:2008(Marking : Symbol for class II) |
- |
10 |
|
Test |
| Cl.7.1 of IS 302-1:2008(Marking : Molel or type) |
- |
10 |
|
Test |
| Cl.7.1 of IS 302-1:2008(Marking : Manufacture identification) |
- |
10 |
|
Test |
| Cl.7.1 of IS 302-1:2008(Marking : Rated power input) |
- |
10 |
|
Test |
| Cl.7.1 of IS 302-1:2008(Marking : Nature of supply) |
- |
10 |
|
Test |
| Cl.7.1 of IS 302-1:2008(Marking : Rated Voltage) |
- |
10 |
|
Test |
| 15.4 (b)(Cold impact) |
- |
10 |
|
Test |
|
- |
- - |