781 |
NAWaL Analytical Labs India Private Limited, Hosur
| 6126416
| IS 13334 : Part 1 (2014) |
Skimmed milk powder - Specification: Part 1 standard grade (Second Revision) |
Standard Grade |
8300 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
5.6(Scorched particles) |
- |
500 |
|
18% GST extra |
5.6(Titratable acidity (lactic acid)) |
- |
500 |
|
18% GST extra |
5.6(Total ash (on dry basis)) |
- |
500 |
|
18% GST extra |
5.6(Insolubility index) |
- |
500 |
|
18% GST extra |
5.6(Milk fat) |
- |
1100 |
|
18% GST extra |
5.6(Milk protein in milk solids not fat) |
- |
500 |
|
18% GST extra |
5.6(Listeria monocytogenes) |
- |
500 |
|
18% GST extra |
5.6(Spore count, Anaerobic (Sulfite reducing Clostridia)) |
- |
500 |
|
18% GST extra |
5.6(Spore count, Aerobic (Bacillus cereus)) |
- |
500 |
|
18% GST extra |
5.6(Salmonella) |
- |
500 |
|
18% GST extra |
5.6(Coagulase positive Staphylococcus aureus) |
- |
500 |
|
18% GST extra |
5.6(Escherichia coli) |
- |
500 |
|
18% GST extra |
5.6(Coliform count ) |
- |
500 |
|
18% GST extra |
5.6(Bacterial count) |
- |
500 |
|
18% GST extra |
5.6(Moisture) |
- |
500 |
|
18% GST extra |
|
21 Mar, 2028 |
- - |
782 |
Arihant Analytical Laboratory Pvt. Ltd., Sonipat
| 9167906
| IS 17790 (2022) |
INSULATED FLASK FOR DOMESTIC USE SPECIFICATION |
All Type |
28500 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
5.0(Manufacture and Workmanship) |
- |
28500 |
|
- |
5.3(Welding Defects) |
- |
28500 |
|
- |
7.1(Material) |
- |
28500 |
|
- |
7.1.2.1 & 7.1.2.2(Thickness) |
- |
28500 |
|
- |
7.1.3(Coating Thickness) |
- |
28500 |
|
- |
7.1.3(Material – coating cadmium) |
- |
28500 |
|
- |
7.1.2.2(Bisphenol A (BPA)) |
- |
28500 |
|
- |
7.1.4.3(O-Ring / Washer- Defects) |
- |
28500 |
|
- |
7.2(Capacity) |
- |
28500 |
|
- |
7.3(Heat Retention Capability) |
- |
28500 |
|
- |
7.4(Cold Retention Capability) |
- |
28500 |
|
- |
7.5.1(Drop Impact Test) |
- |
28500 |
|
- |
7.5.2(Pendulum Impact Test) |
- |
28500 |
|
- |
7.6(Fixing Strength of the Handle) |
- |
28500 |
|
- |
7.7(Test for Strength of Shoulder Strap) |
- |
28500 |
|
- |
7.8(Test for strength of cord) |
- |
28500 |
|
- |
7.9(Leakage Test) |
- |
28500 |
|
- |
7.10(Joint Leak Test) |
- |
28500 |
|
- |
7.11(Staining Test) |
- |
28500 |
|
- |
7.13(Seepage test) |
- |
28500 |
|
- |
7.14(Test for Lever, device for operating Or regulating flow test) |
- |
28500 |
|
- |
7.15(Test for length of the shoulder cap) |
- |
28500 |
|
- |
7.16(Stability of Flask) |
- |
28500 |
|
- |
7.17(Pour Test) |
- |
28500 |
|
- |
9.1(Marking) |
- |
28500 |
|
- |
9.2(BIS certification marking) |
- |
28500 |
|
- |
10(Packaging) |
- |
28500 |
|
- |
7.1.3(Coating- Adhesion test) |
- |
28500 |
|
- |
7.1.3(Coating - Thickness test) |
- |
28500 |
|
- |
7.1.3(Coating- Salt water corrosion test) |
- |
28500 |
|
- |
7.1.4.1(Stopper) |
- |
28500 |
|
- |
7.1.4.2(O-ring/washer- Overall migration) |
- |
28500 |
|
- |
7.1.4.2(O-ring/washer- Shore hardness) |
- |
28500 |
|
- |
7.1.4.2(O-ring/washer- BPA) |
- |
28500 |
|
- |
7.1.5(Auxillary closure) |
- |
28500 |
|
- |
7.12(Check for PUF (Polyurethane Foam) or Any Other Similar Thermal Insulation Material) |
- |
28500 |
|
- |
7.18(Endurance Test for O-Ring, Washer and Stopper) |
- |
28500 |
|
- |
|
02 Jun, 2027 |
- Included w.e.f.27.06.2025 |
783 |
Havells India Limited (Havells Research & Development Laboratory)
| 8187226
| IS/IEC 60947 : Part 4 : Sec 1 (2018) |
Low-Voltage switchgear and controlgear : Part 4-1 Contactors and motor starters electromechanical contactors and motor-Starters |
Contactors and Motor-Starters |
2235000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
8.1.2(Materials) |
- |
0 |
|
Only for internal testing |
8.1.2.1(General materials requirements) |
- |
0 |
|
Only for internal testing |
8.1.2.2(Glow wire testing) |
- |
15000 |
|
Only for internal testing |
8.1.3(Current-carrying parts and their connections) |
- |
0 |
|
Only for internal testing |
8.1.4(Clearances and creepage distances) |
- |
20000 |
|
Only for internal testing |
8.1.5.1(Insulation) |
- |
10000 |
|
Only for internal testing |
8.1.5.2(Direction of movement) |
- |
10000 |
|
Only for internal testing |
8.1.5.3(Mounting) |
- |
10000 |
|
Only for internal testing |
8.1.5.4(Protection) |
- |
0 |
|
Only for internal testing |
8.1.8(Terminals) |
- |
10000 |
|
Only for internal testing |
8.1.8.1(General) |
- |
10000 |
|
Only for internal testing |
8.1.8.2(Terminal identification and marking) |
- |
10000 |
|
Only for internal testing |
8.1.10(Provisions for protective earthing) |
- |
0 |
|
Only for internal testing |
8.1.11(Enclosures for equipment) |
- |
20000 |
|
Only for internal testing |
8.1.11.1(Design) |
- |
0 |
|
Only for internal testing |
8.1.11.2(Insulation) |
- |
10000 |
|
Only for internal testing |
8.1.12(Degrees of protection of enclosed equipment) |
- |
30000 |
|
Only for internal testing |
8.1.14(Limited energy source) |
- |
10000 |
|
Only for internal testing |
8.1.14.1(General) |
- |
0 |
|
Only for internal testing |
8.1.14.2(Limited energy source with galvanic separation) |
- |
0 |
|
Only for internal testing |
8.1.16(Fault and abnormal conditions) |
- |
10000 |
|
Only for internal testing |
8.1.17(Short-circuit and overload protection of ports) |
- |
10000 |
|
Only for internal testing |
8.2(Performance requirements) |
- |
0 |
|
Only for internal testing |
8.2.1(Operating conditions) |
- |
0 |
|
Only for internal testing |
8.2.1.1.1(General conditions) |
- |
0 |
|
Only for internal testing |
8.2.1.2(Limits of operation of contactors and power-operated starters) |
- |
10000 |
|
Only for internal testing |
8.2.1.3(Limits of operation of under-voltage relays and releases) |
- |
10000 |
|
Only for internal testing |
8.2.1.4(Limits of operation of shunt-coil operated releases (shunt trip)) |
- |
10000 |
|
Only for internal testing |
8.2.1.5(Limits of operation of current sensing relays and releases) |
- |
10000 |
|
Only for internal testing |
8.2.1.5.1(Limits of operation of time-delay overload relays when all poles are energized) |
- |
10000 |
|
Only for internal testing |
8.2.1.5.1.1(General tripping requirements of overload relays) |
- |
20000 |
|
Only for internal testing |
8.2.1.5.2(Limits of operation of three-pole time-delay overload relays energized on two poles) |
- |
20000 |
|
Only for internal testing |
8.2.1.5.3(Limits of operation of instantaneous magnetic overload relays) |
- |
10000 |
|
Only for internal testing |
8.2.1.5.4(Limits of operation of under-current relays and releases for automatic change over) |
- |
10000 |
|
Only for internal testing |
8.2.1.5.4.1(Limits of operation of under-current relays) |
- |
10000 |
|
Only for internal testing |
8.2.1.5.4.2(Limits of operation of automatic change over by under-current relays) |
- |
10000 |
|
Only for internal testing |
8.2.2(Temperature-rise) |
- |
30000 |
|
Only for internal testing |
8.2.2.3(Accessible parts) |
- |
10000 |
|
Only for internal testing |
8.2.2.4(Ambient air temperature) |
- |
10000 |
|
Only for internal testing |
8.2.2.5(Main circuit) |
- |
0 |
|
Only for internal testing |
8.2.2.6(Control circuits) |
- |
0 |
|
Only for internal testing |
8.2.2.7.1(Uninterrupted and eight-hour duty windings) |
- |
10000 |
|
Only for internal testing |
8.2.3(Dielectric properties) |
- |
20000 |
|
Only for internal testing |
8.2.3.2(Voltage limiting components between circuits) |
- |
0 |
|
Only for internal testing |
8.2.4.3.1(Mechanical durability) |
- |
20000 |
|
Only for internal testing |
8.2.4.3.2(Electrical durability) |
- |
20000 |
|
Only for internal testing |
8.2.4.4(Overload current withstand capability of contactors) |
- |
30000 |
|
Only for internal testing |
8.2.4.5(Coil power consumption) |
- |
30000 |
|
Only for internal testing |
8.2.4.6(Pole impedance) |
- |
30000 |
|
Only for internal testing |
8.2.4.7(Ability of a MPSD to make and break under short-circuit conditions) |
- |
100000 |
|
Only for internal testing |
8.2.5.1(Performance under short-circuit conditions) |
- |
200000 |
|
Only for internal testing, as per each rating |
8.2.5.3(Co-ordination test between AC-3e rated starter and associated SCPD) |
- |
200000 |
|
Only for internal testing, as per each rating |
8.2.5.4(Co-ordination between a MPSD and another short-circuit protective device) |
- |
200000 |
|
200000 |
9.1.5.2(Environment tests) |
- |
0 |
|
Only for internal testing |
9.2.4(Limited energy source test) |
- |
10000 |
|
Only for internal testing |
9.3.3.2(Operating limits) |
- |
20000 |
|
Only for internal testing |
9.3.3.2.1.2(Coil power consumption) |
- |
30000 |
|
Only for internal testing |
9.3.3.2.1.3(Pole impedance) |
- |
30000 |
|
Only for internal testing |
9.3.3.2.2(Relays and releases) |
- |
20000 |
|
Only for internal testing |
9.3.3.3.1(Ambient air temperature) |
- |
0 |
|
Only for internal testing |
9.3.3.3.2(Measurement of the temperature of parts) |
- |
30000 |
|
Only for internal testing |
9.3.3.3.3(Temperature-rise of a part) |
- |
30000 |
|
Only for internal testing |
9.3.3.3.4(Temperature-rise of the main circuit) |
- |
30000 |
|
Only for internal testing |
9.3.3.3.5(Temperature-rise of control circuits) |
- |
30000 |
|
Only for internal testing |
9.3.3.3.6(Temperature-rise of coils and electromagnets) |
- |
30000 |
|
Only for internal testing |
9.3.3.3.7(Temperature-rise of auxiliary circuits) |
- |
30000 |
|
Only for internal testing |
9.3.3.3.8(Temperature-rise of starting resistors for rheostatic rotor starters) |
- |
30000 |
|
Only for internal testing |
9.3.3.6(Operational performance capability) |
- |
80000 |
|
Only for internal testing |
9.3.4.2.2(prospective current) |
- |
200000 |
|
Only for internal testing, as per each rating |
9.3.4.2.3(Test at the rated conditional short-circuit current Iq) |
- |
200000 |
|
Only for internal testing, as per each rating |
9.3.5(Overload current withstand capability of contactors) |
- |
30000 |
|
Only for internal testing |
9.3.6.2(Operation and operating limits) |
- |
30000 |
|
Only for internal testing |
9.3.6.3(Dielectric tests) |
- |
20000 |
|
Only for internal testing |
9.3.6.4(Mechanical operation tests of a MPSD) |
- |
90000 |
|
Only for internal testing |
8.2.4 of IEC 60947-1:2007 (Sequence 5)(Verification of Mechanical properties of terminals) |
- |
30000 |
|
Only for internal testing |
Annex C of IEC 60947-1:2007 (Sequence 5)(Verification of Degree of protection of enclosed contactors and starters) |
- |
30000 |
|
Only for internal testing |
|
07 Aug, 2028 |
- - |
784 |
Havells India Limited (Havells Research & Development Laboratory)
| 8187226
| IS/IEC 60947 : Part 2 (2016) |
Low - Voltage switchgear and controlgear: Part 2 circuit - Breakers (First Revision) |
Circuit-Breakers |
3874000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
8.3.3.2(Tripping limits and characteristics) |
- |
100000 |
|
Only for internal testing |
8.3.3.3(Test of dielectric properties) |
- |
65000 |
|
Only for internal testing |
8.3.3.4(Mechanical operation and operational performance capability) |
- |
90000 |
|
Only for internal testing |
8.3.3.5(Overload performance) |
- |
150000 |
|
Only for internal testing |
8.3.3.6(Verification of dielectric withstand) |
- |
30000 |
|
Only for internal testing |
8.3.3.7(Verification of temperature-rise) |
- |
25000 |
|
Only for internal testing |
8.3.3.8(Verification of Overload releases) |
- |
4000 |
|
Only for internal testing |
8.3.3.9(Verification of undervoltage and shunt releases) |
- |
10000 |
|
Only for internal testing |
8.3.3.10(Verification of main contact position) |
- |
5000 |
|
Only for internal testing |
8.3.4.3(Verification of operational performance capability) |
- |
50000 |
|
Only for internal testing |
8.3.8.5(Verification of operational performance capability) |
- |
30000 |
|
Only for internal testing |
8.4.2(Mechanical operation tests) |
- |
15000 |
|
Only for internal testing |
8.4.3(Verification of the calibration of overcurrent releases) |
- |
10000 |
|
Only for internal testing |
8.4.4(Verification of the operation of undervoltage and shunt releases) |
- |
10000 |
|
Only for internal testing |
8.4.6(Dielectric tests) |
- |
60000 |
|
Only for internal testing |
8.4.7(Test for the verifiacation of clearances less than those corresponding to case A of Table 13 of IEC 60947-1:2007) |
- |
3000 |
|
Only for internal testing |
8.3.4.4(Verification of dielectric withstand) |
- |
28000 |
|
Only for internal testing |
8.3.5.4(Verification of dielectric withstand) |
- |
28000 |
|
Only for internal testing |
8.3.6.6(Verification of dielectric withstand) |
- |
28000 |
|
Only for internal testing |
8.3.8.6(Verification of dielectric withstand) |
- |
28000 |
|
Only for internal testing |
8.3.4.5(Verifiation of temperature-rise) |
- |
25000 |
|
Only for internal testing |
8.3.6.4(Verification of temperature-rise) |
- |
25000 |
|
Only for internal testing |
8.3.8.7(Verification of temperature-rise) |
- |
25000 |
|
Only for internal testing |
8.3.4.6(Verification of Overload releases) |
- |
5000 |
|
Only for internal testing |
8.3.5.2(Verification of Overload releases) |
- |
5000 |
|
Only for internal testing |
8.3.5.5(Verification of Overload releases) |
- |
5000 |
|
Only for internal testing |
8.3.6.2(Verification of Overload releases) |
- |
5000 |
|
Only for internal testing |
8.3.6.7(Verification of Overload releases) |
- |
5000 |
|
Only for internal testing |
8.3.8.2(Verification of Overload releases) |
- |
5000 |
|
Only for internal testing |
8.3.8.8(Verification of Overload releases) |
- |
5000 |
|
Only for internal testing |
8.3.4.1(General) |
- |
0 |
|
Only for internal testing |
8.3.4.2(Test of service short circuit breaking capacity) |
- |
10000 |
|
Only for internal testing |
8.3.5.1(General) |
- |
0 |
|
Only for internal testing |
8.3.5.3(Rated ultimate short-circuit breaking capacity) |
- |
200000 |
|
Only for internal testing as per each rating |
8.3.6.1(General) |
- |
0 |
|
Only for internal testing |
8.3.6.3(Rated short-time withstand current) |
- |
200000 |
|
Only for internal testing as per each rating |
8.3.6.5(Short-circuit breaking capacity at maximum short-time withstand current) |
- |
200000 |
|
Only for internal testing as per each rating |
8.3.7.1(General) |
- |
0 |
|
Only for internal testing |
8.3.8.1(General) |
- |
0 |
|
Only for internal testing |
8.3.8.3(Rated short-time withstand current) |
- |
200000 |
|
Only for internal testing as per each rating |
8.3.8.4(Rated service short-circuit breaking capacity*) |
- |
200000 |
|
Only for internal testing as per each rating |
8.3.4.1(General) |
- |
0 |
|
Only for internal testing |
8.3.4.2(rated short circuit breaking capacity (sequence II)) |
- |
200000 |
|
Only for internal testing as per each rating |
8.3.4.3(verification of operational performance capability (sequence II)) |
- |
50000 |
|
Only for internal testing |
8.3.4.4(verification of dielectric withstand (sequnce II)) |
- |
28000 |
|
Only for internal testing |
8.3.4.5(verification of temperature-rise (sequence II)) |
- |
25000 |
|
Only for internal testing |
8.3.4.6(verification of overload releases (sequence II)) |
- |
5000 |
|
Only for internal testing |
8.3.5.1(General) |
- |
0 |
|
Only for internal testing |
8.3.5.2(verification of overload releases (sequence III)) |
- |
5000 |
|
Only for internal testing |
8.3.5.3(rated short circuit breaking capacity (sequence III)) |
- |
200000 |
|
Only for internal testing as per each rating |
8.3.5.4(verification of dielectric withstand (sequnce III)) |
- |
28000 |
|
Only for internal testing |
8.3.5.5(verification of overload releases (sequence III)) |
- |
5000 |
|
Only for internal testing |
8.3.6.1(General) |
- |
0 |
|
Only for internal testing |
8.3.6.2(verification of overload releases (sequence IV)) |
- |
5000 |
|
Only for internal testing |
8.3.6.3(rated short circuit withstand current (sequence IV)) |
- |
200000 |
|
Only for internal testing as per each rating |
8.3.6.4(verification of temperature-rise (sequence IV)) |
- |
25000 |
|
Only for internal testing |
8.3.6.5(short circuit breaking capacity at maximum short time withstand current (sequence IV)) |
- |
200000 |
|
Only for internal testing as per each rating |
8.3.6.6(verification of dielectric withstand (sequence IV)) |
- |
28000 |
|
Only for internal testing |
8.3.6.7(verification of overload releases (sequence IV)) |
- |
5000 |
|
Only for internal testing |
8.3.8.1(General) |
- |
0 |
|
Only for internal testing |
8.3.8.2(verification of overload releases (sequence VI)) |
- |
5000 |
|
Only for internal testing |
8.3.8.3(rated short time withstand current (sequence VI)) |
- |
200000 |
|
Only for internal testing as per each rating |
8.3.8.4(rated service short circuit breaking capacity (sequence VI)) |
- |
200000 |
|
Only for internal testing as per each rating |
8.3.8.5(verification of operational performance capability (sequence VI)) |
- |
50000 |
|
Only for internal testing |
8.3.8.6(verification of dielectric withstand (sequence VI)) |
- |
28000 |
|
Only for internal testing |
8.3.8.7(verification of temperature-rise (sequence VI)) |
- |
25000 |
|
Only for internal testing |
8.3.8.8(verification of overload releases (sequence VI)) |
- |
5000 |
|
Only for internal testing |
C.2(individual pole short circuit breaking capacity (Isu)) |
- |
200000 |
|
Only for internal testing as per each rating |
C.3(verification of dielectric withstand) |
- |
25000 |
|
Only for internal testing |
C.4(verification of overload releases) |
- |
5000 |
|
Only for internal testing |
H.2(individual pole short circuit (IIT)) |
- |
200000 |
|
Only for internal testing as per each rating |
H.3(verification of dielectric withstand) |
- |
28000 |
|
Only for internal testing |
H.4(verification of overload releases) |
- |
5000 |
|
Only for internal testing |
|
07 Aug, 2028 |
- - |
785 |
AJEO TESTING LABS PVT LTD, GHAZIABAD
| 8178606
| IS 1554 : Part 1 (1988) |
Specification for pvc insulated (Heavy Duty) electric cables: Part 1 for working voltages up to and including 1100 v (Third Revision) |
1100 V |
12000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
3.1(MATERIALS : CONDUCTOR) |
- |
500 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
4.1.1(INSULATION : General Purjose Insulaiion) |
- |
300 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
4.1.2(INSULATION : Heat Resisting Insulation) |
- |
300 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
5.1(MATERIALS : FILLER AND INNER SHEATH) |
- |
300 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
5.2(MATERIALS : FILLER AND INNER SHEATH) |
- |
300 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
6.1(MATERIALS : ARMGURING) |
- |
300 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
6.2(MATERIALS : ARMGURING) |
- |
300 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
7.1.1(OUTER SHEATH : For Cables with General Purpose InsuIafion) |
- |
300 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
7.1.2(OUTER SHEATH : For Cables with Heat Resisting InsuIalion) |
- |
300 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
8.1(CONSTRUCTION : CONDUCTOR) |
- |
300 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
8.2(CONSTRUCTION : CONDUCTOR) |
- |
300 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
9.1(INSULATION ) |
- |
400 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
9.2(INSULATION : Thickness of Insulation) |
- |
500 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
9.3(INSULATION :Tolerance on Thickness of Insulation) |
- |
500 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
9.4(INSULATION : Application of Insulation) |
- |
300 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
10.1(CORE IDENTIFICATION) |
- |
300 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
10.2(CORE IDENTIFICATION) |
- |
300 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
10.3(CORE IDENTIFICATION) |
- |
300 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
10.3.1(Arrangement of Marking) |
- |
300 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
11.1(LAYING UP OF CORES) |
- |
400 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
11.2(LAYING UP OF CORES) |
- |
400 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
12.1(INNER SHEATH) |
- |
300 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
12.2(INNER SHEATH) |
- |
300 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
12.3(INNER SHEATH :Thickness of Inner Sheath) |
- |
500 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
12.3.1(INNER SHEATH :Thickness of Inner Sheath) |
- |
400 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
13.1.1(ARMOURING : Application) |
- |
300 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
13.1.2(Armouring: Coverage ) |
- |
300 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
13.1.3(ARMOURING : Direction of lay ) |
- |
300 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
13.1.4(ARMOURING : Application) |
- |
300 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
13.2(ARMOURING : Type of Armour) |
- |
300 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
13.2.1(ARMOURING : Type of Armour) |
- |
300 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
13.3(Armouring : Dimensions -Wire Diameter) |
- |
400 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
13.3(Armouring : Dimensions -Formed wire ) |
- |
400 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
13.4(ARMOURING : Joints) |
- |
300 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
13.5.1(ARMOURING : Resistance) |
- |
300 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
13.5.2(ARMOURING : Resistance) |
- |
1000 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
13.6 a)(ARMOURING: Tensile Strength) |
- |
800 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
13.6 b)(ARMOURING: Elongation ) |
- |
800 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
13.6 c)(ARMOURING: Torsion Test (For round wire ) ) |
- |
800 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
13.6 d)(ARMOURING: Winding Test(For formed wire)) |
- |
800 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
13.6 e)(ARMOURING: Uniformity of zinc coating) |
- |
1000 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
13.6 f)(ARMOURING: Mass of zinc coating ) |
- |
1000 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
13.6 g)(ARMOURING: Resistivity) |
- |
1000 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
14.1(OUTER SHEATH) |
- |
200 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
14.2(OUTER SHEATH) |
- |
200 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
14.3(OUTER SHEATH : Colour ) |
- |
200 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
14.4.1(Thickness of Outer Sheath : Unarmowed Cables) |
- |
300 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
14.4.2(Thickness of Outer Sheath : Armoured Cables) |
- |
200 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
15.1 a) 1)(Tests on conductor : Annealing test ( for copper )) |
- |
500 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
15.1 a) 2)(Tensile test (for aluminium) - Before stranding ) |
- |
500 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
15.1 a) 2)(Tensile test (for aluminium) - After stranding ) |
- |
500 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
15.1 a) 3)(Tests on conductor : Wrapping test ( for aluminium )) |
- |
300 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
15.1 a) 4)(Tests on conductor : Conductor resistance test) |
- |
800 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
15.1 a) 4)(Resistance test - Neutral conductor ) |
- |
800 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
15.1 d)1)(Phyaical tests for insulation : Tensile Test) |
- |
500 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
15.1 d)1)(Phyaical tests for insulation : Elongation ) |
- |
500 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
15.1 d)1)(Physical tests for sheath : Tensile stregth ) |
- |
500 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
15.1 d)1)(Physical tests for sheath : Elongation ) |
- |
500 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
15.1 d)2)(Phyaical tests for insulation- Ageing in air Oven : Tensile Test) |
- |
1500 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
15.1 d)2)(Phyaical tests for insulation - Ageing in air oven : Elongation ) |
- |
1500 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
15.1 d)2)(Phyaical tests for insulation - Ageing in air Oven : Tensile Variation ) |
- |
1500 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
15.1 d)2)(Phyaical tests for insulation- Ageing in air oven : Elongation Variation ) |
- |
1500 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
15.1 d)2)(Physical tests for outer sheath- Ageing in air oven : Tensile stregth ) |
- |
1500 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
15.1 d)2)(Physical tests for outer sheath -Ageing in air oven : Elongation ) |
- |
1500 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
15.1 d)2)(Physical tests for outer sheath- Ageing in air oven : Tensile stregth Variation ) |
- |
1500 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
15.1 d)2)(Physical tests for outer sheath -Ageing in air oven : Elongation Variation ) |
- |
1500 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
15.1 d)3)(Phyaical tests for insulation : Shrinkage ) |
- |
500 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
15.1 d)3)(Phyaical tests for insulation : Shrinkage - Crack observed ) |
- |
500 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
15.1 d)3)(Phyaical tests for Sheath : Shrinkage ) |
- |
500 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
15.1 d)3)(Phyaical tests for Sheath : Shrinkage - Crack observed ) |
- |
500 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
15.1 d)4)(Hot deformation : Insulation ) |
- |
500 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
15.1 d)4)(Hot deformation : Sheath ) |
- |
500 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
15.1 d)5)( Loss of mass in air oven- Insulation ) |
- |
2000 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
15.1 d)5)( Loss of mass in air oven- sheath ) |
- |
2000 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
15.1 d)6)(Heat shock test- Insulation ) |
- |
500 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
15.1 d)6)(Heat shock test- sheath ) |
- |
500 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
15.1 d)7)(Thermal stability- insulation ) |
- |
600 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
15.1 d)7)(Thermal stability- Sheath ) |
- |
600 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
15.1 e)(Insulation resistance test : Volume Resistivity ) |
- |
1000 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
15.1 e)(Insulation resistance test : IR Constant ) |
- |
1000 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
15.1 f)(High voltage test ( water immersion test )) |
- |
1500 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
15.1 g)(High voltage test at room temperature) |
- |
1500 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
15.1 g)(High voltage test at room temperature) |
- |
1500 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
15.4 a)(Cold bend test- Insulation ( Optional test)) |
- |
800 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
15.4 a)(Cold bend test- Sheath ( Optional test)) |
- |
800 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
15.4 b)(Cold impact test- Insulation ( Optional test)) |
- |
800 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
15.4 b)(Cold impact test- Sheath ( Optional test)) |
- |
800 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
15.4 c)(Armour resistance test ( for other than mining cables ).- Optional test ) |
- |
500 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
16.1(DETAILS OF TESTS : General) |
- |
200 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
16.2(DETAILS OF TESTS : High Voltage Test at Room Temperature) |
- |
1500 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
16.3.1(High Voltage Test ( Water Immersion Test ) : a.c. Test) |
- |
1500 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
16.3.2(High Voltage Test ( Water Immersion Test ) : d.c. Test) |
- |
1500 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
16.4(Flammability Test) |
- |
800 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
16.5(Oxygen Index Test) |
- |
2500 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
16.6(Flame Retardance Test on Single Cables) |
- |
2500 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
16.7(Flame Retardance Test on Bunched Cables) |
- |
3000 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
16.9(Test for Halogen Acid Gas Evolution) |
- |
2000 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
16.1(Temperature Index) |
- |
2000 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
17.1(IDENTIFICATION : Manufacturer’s Identification) |
- |
300 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
17.2(IDENTIFICATION : Cable Identification) |
- |
300 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
17.2.1(IDENTIFICATION : Cable Identification) |
- |
300 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
17.3(IDENTIFICATION : Cable Code) |
- |
300 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
15.1.e(Insulation resistance Test- Insulation resistance At Maximum rated temperature temperature) |
- |
1000 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
15.1.e(Insulation resistance Test- Insulation resistance constant At Room temperature) |
- |
1000 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
15.1.e(Insulation resistance Test- Volume Resistivity At Maximum rated temperature temperature) |
- |
1000 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
15.1.e(Insulation resistance Test- Volume Resistivity At Room temperature) |
- |
1000 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
16.4(Flammability Test- Un affected portion) |
- |
1000 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
16.4(Flammability Test- Period of Burning) |
- |
800 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
9.3(Minimum Thickness of Reduce core insulation) |
- |
500 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
9.2(Thickness of Reduce core insulation) |
- |
500 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
3.1 Table 2
IS 8130(Number of wires in the conductor) |
- |
500 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
Cl No. 16.10(Smoke density test) |
- |
500 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
Cl No. 16.8(Test for specific optical density of smoke) |
- |
500 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
Table 4(Copper purity test) |
- |
500 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
Cl.8(Conductor, Number of wires.) |
- |
500 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
Cl.8(Conductor, Number of wires.) |
- |
200 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
Cl.8(Flexibility class) |
- |
200 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
[(Cl.15), (d), 2](After ageing, Elongation of Sheath [Percentage]) |
- |
1500 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
Cl No. 16.10(Smoke density test) |
- |
3500 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
Cl No. 16.8(Test for specific optical density of smoke) |
- |
3500 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
Table 4(Copper purity test) |
- |
3500 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
Cl.8(Conductor, Number of wires.) |
- |
500 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
Cl.8(Conductor, Number of wires.) |
- |
500 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
Cl.8(Flexibility class) |
- |
500 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
[(Cl.15), (d), 2](After ageing, Elongation of Sheath [Percentage]) |
- |
1500 |
|
GST @ 18% will be charged extra as applicable presently any change by the Govt either increase or decrease will be charged extra |
|
10 Jul, 2027 |
- Included w.e.f.04.07.2025 |
786 |
JBS TESTING SOLUTIONS PVT LTD (27), JALANDHAR
| 9164606
| IS 7485 : Part 1 (2018) |
Countersunk Flat Head Screws (Common head Style) With Type H or Type Z Cross Recess - Product Grade A Part 1 Steel Screws of Property Class 4.8 ( Third Revision) |
- |
19400 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
3(Dimensions) |
- |
8000 |
|
For complete dimension and other qualitative tests |
4, table 2(Material) |
- |
5000 |
|
For chemical testing |
4, table 2(General requirements) |
- |
8000 |
|
For complete dimension and other qualitative tests |
4, table 2(Thread) |
- |
8000 |
|
For complete dimension and other qualitative tests |
4, table 2(Mechanical property) |
- |
6400 |
|
For mechanical tests |
4, table 2(Tolerances) |
- |
8000 |
|
For complete dimension and other qualitative tests |
4, table 2(Cross recess) |
- |
8000 |
|
For complete dimension and other qualitative tests |
4, table 2(Finish - coating) |
- |
8000.01 |
|
For complete dimension and other qualitative tests |
4, table 2(Surface integrity) |
- |
8000.03 |
|
For complete dimension and other qualitative tests |
4, table 2(Acceptability) |
- |
8000 |
|
For complete dimension and other qualitative tests |
5(Designation) |
- |
8000 |
|
For complete dimension and other qualitative tests |
|
04 Dec, 2028 |
- Included w.e.f 16.06.2025 |
787 |
JBS TESTING SOLUTIONS PVT LTD (27), JALANDHAR
| 9164606
| IS 13983 (1994) |
Stainless Steel Sinks For Domestic Purposes |
- |
19500 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
9(Marking) |
- |
1000 |
|
For other qualitative test |
4(Type) |
- |
1000 |
|
For other qualitative test |
Cl. 5 , As per IS 5522-2014, Cl. 7.2 , Table 1 & 2 Grade Desig X-04-Cr-19-Ni-19 (Numeric Symbol 304)(Carbon Content) |
- |
5000 |
|
For chemical test |
Cl. 5 , As per IS 5522-2014, Cl. 7.2 , Table 1 & 2 Grade Desig X-04-Cr-19-Ni-19 (Numeric Symbol 304)(Silicon Content) |
- |
5000 |
|
For chemical test |
Cl. 5 , As per IS 5522-2014, Cl. 7.2 , Table 1 & 2 Grade Desig X-04-Cr-19-Ni-19 (Numeric Symbol 304)(Manganese Content) |
- |
5000 |
|
For chemical test |
Cl. 5 , As per IS 5522-2014, Cl. 7.2 , Table 1 & 2 Grade Desig X-04-Cr-19-Ni-19 (Numeric Symbol 304)(Nickel Content) |
- |
5000 |
|
For chemical test |
Cl. 5 , As per IS 5522-2014, Cl. 7.2 , Table 1 & 2 Grade Desig X-04-Cr-19-Ni-19 (Numeric Symbol 304)(Chromium Content) |
- |
5000 |
|
For chemical test |
Cl. 5 , As per IS 5522-2014, Cl. 7.2 , Table 1 & 2 Grade Desig X-04-Cr-19-Ni-19 (Numeric Symbol 304)(Sulphur Content) |
- |
5000 |
|
For chemical test |
Cl. 5 , As per IS 5522-2014, Cl. 7.2 , Table 1 & 2 Grade Desig X-04-Cr-19-Ni-19 (Numeric Symbol 304)(Phouphorous Content) |
- |
5000 |
|
For chemical test |
Cl. 5 , As per IS 5522-2014, Cl. 7.2 , Table 1 & 2 Grade Desig X-04-Cr-19-Ni-19 (Numeric Symbol 304)(Nitrogen Content) |
- |
5000 |
|
For chemical test |
Cl. 5 , As per IS 5522-2014, Cl. 7.2 , Table 1 & 2 Grade Desig X-07-Cr-18-Ni-9 (Numeric Symbol 302)(Carbon Content) |
- |
5000 |
|
For chemical test |
Cl. 5 , As per IS 5522-2014, Cl. 7.2 , Table 1 & 2 Grade Desig X-07-Cr-18-Ni-9 (Numeric Symbol 302)(Silicon Content) |
- |
5000 |
|
For chemical test |
Cl. 5 , As per IS 5522-2014, Cl. 7.2 , Table 1 & 2 Grade Desig X-07-Cr-18-Ni-9 (Numeric Symbol 302)(Manganese Content) |
- |
5000 |
|
For chemical test |
Cl. 5 , As per IS 5522-2014, Cl. 7.2 , Table 1 & 2 Grade Desig X-07-Cr-18-Ni-9 (Numeric Symbol 302)(Nickel Content) |
- |
5000 |
|
For chemical test |
Cl. 5 , As per IS 5522-2014, Cl. 7.2 , Table 1 & 2 Grade Desig X-07-Cr-18-Ni-9 (Numeric Symbol 302)(Chromium Content) |
- |
5000 |
|
For chemical test |
Cl. 5 , As per IS 5522-2014, Cl. 7.2 , Table 1 & 2 Grade Desig X-07-Cr-18-Ni-9 (Numeric Symbol 302)(Sulphur Content) |
- |
5000 |
|
For chemical test |
Cl. 5 , As per IS 5522-2014, Cl. 7.2 , Table 1 & 2 Grade Desig X-07-Cr-18-Ni-9 (Numeric Symbol 302)(Phouphorous Content) |
- |
5000 |
|
For chemical test |
Cl. 5 , As per IS 5522-2014, Cl. 7.2 , Table 1 & 2 Grade Desig X-07-Cr-18-Ni-9 (Numeric Symbol 302)(Nitrogen Content) |
- |
5000 |
|
For chemical test |
6(Thickness of sheet/strip) |
- |
5000 |
|
For chemical test |
6(Depth of bowl) |
- |
13500 |
|
For dimensional and tolerance tests |
6(Internal dimensions of the bowl) |
- |
13500 |
|
For dimensional and tolerance tests |
6(Bowl locating limits) |
- |
13499.98 |
|
For dimensional and tolerance tests |
6(Co-ordinating sizes) |
- |
13500 |
|
For dimensional and tolerance tests |
7.1(Consruction and workmanship) |
- |
1000 |
|
For other qualitative test |
7.1.1(Consruction and workmanship) |
- |
1000 |
|
For other qualitative test |
7.2(Consruction and workmanship) |
- |
1000 |
|
For other qualitative test |
7.2.1(Consruction and workmanship) |
- |
1000 |
|
For other qualitative test |
7.3(Drainers) |
- |
1000 |
|
For other qualitative test |
7.4(Waste outlet) |
- |
1000 |
|
For other qualitative test |
7.5(Tap holes) |
- |
1000 |
|
For other qualitative test |
7.6(Overflows) |
- |
1000 |
|
For other qualitative test |
8(Finish) |
- |
1000 |
|
For other qualitative test |
5(MATERIALS) |
- |
1000 |
|
For other qualitative test |
6.1.1(Thickness of Sheet/Strip) |
- |
13500 |
|
For dimensional and tolerance tests |
6.1.2(Thickness of Sheet/Strip) |
- |
13500 |
|
For dimensional and tolerance tests |
6.2(Depth of Bowls) |
- |
13500 |
|
For dimensional and tolerance tests |
6.3(Internal Dimensions of Bowls) |
- |
13500 |
|
For dimensional and tolerance tests |
6.4.1(Bowl Locating Limits) |
- |
13500 |
|
For dimensional and tolerance tests |
6.5(Coordinating Sizes) |
- |
13500 |
|
For dimensional and tolerance tests |
7.1(CONSTRUCTION AND WORKMANSHIP) |
- |
1000 |
|
- |
7.1.1(CONSTRUCTION AND WORKMANSHIP) |
- |
1000 |
|
- |
7.2.1(CONSTRUCTION AND WORKMANSHIP) |
- |
1000 |
|
- |
7.3(CONSTRUCTION AND WORKMANSHIP) |
- |
1000 |
|
- |
7.4(Waste Outlet) |
- |
1000 |
|
- |
7.5(Tap Holes) |
- |
1000.01 |
|
- |
7.6(OVERFLOW) |
- |
13500.02 |
|
- |
Clause no. 4(types) |
- |
1000 |
|
- |
Caluse no. 5("Material -Austenitic stainless steel of
Grade Designation") |
- |
13500.01 |
|
- |
Clause no. 6.1(Thickness of sheet) |
- |
13500.03 |
|
- |
Clause no. 6.2(Depth of Bowls) |
- |
13500 |
|
- |
Clause no. 6.3(Internal dimensions of bowls) |
- |
13500 |
|
- |
Clause no. 6.4(Bowl Locating Limits) |
- |
13500 |
|
- |
Clause no. 6.5, Table No. 1(Dimension of the sink) |
- |
13500 |
|
- |
Clause no. 7(Construction and workmanship) |
- |
1000.02 |
|
- |
Clause no. 8(Finish) |
- |
1000 |
|
- |
Clause no. 9(Mark) |
- |
1000 |
|
- |
|
04 Dec, 2028 |
- Included w.e.f 16.06.2025 |
788 |
BCH Electric Limited, Faridabad
| 8186026
| IS/IEC 60947 : PART 3 (2020) |
Low-Voltage Switchgear and Controlgear: Part 3 Switches Disconnectors Switch-Disconnectors and Fuse-Combination Units |
I MCB SOLATOR, MCCB ISOLATOR SWITCH, SWITCH DISCONNECTORS, FUSE COMBINATION |
820000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
3.1(General) |
- |
2000 |
|
Only for internal testing |
4(Classification) |
- |
2000 |
|
Only for internal testing |
5.3.2(Rated voltages) |
- |
2000 |
|
Only for internal testing |
5.3.2.1(Rated operational voltage) |
- |
2000 |
|
Only for internal testing |
5.3.2.2(Rated insulation voltage) |
- |
2000 |
|
Only for internal testing |
5.3.2.3(Rated impulse withstand voltage) |
- |
2000 |
|
Only for internal testing |
5.3.3(Currents) |
- |
2000 |
|
Only for internal testing |
5.3.3.2(Conventional free air thermal current) |
- |
2000 |
|
Only for internal testing |
5.3.3.3(Conventional enclosed thermal current) |
- |
2000 |
|
Only for internal testing |
5.3.3.4(Rated operational current (Ie) or rated operational power) |
- |
2000 |
|
Only for internal testing |
5.3.3.5(Rated uninterrupted current) |
- |
2000 |
|
Only for internal testing |
5.3.4(Rated frequency) |
- |
2000 |
|
Only for internal testing |
5.3.5(Rated duty) |
- |
2000 |
|
Only for internal testing |
5.3.5.2(Eight-hour duty) |
- |
1000 |
|
Only for internal testing |
5.3.5.3(Uninterrupted duty) |
- |
1000 |
|
Only for internal testing |
5.3.6.1(Ability to withstand motor switching overload currents) |
- |
2000 |
|
Only for internal testing |
5.3.6.2(Rated making capacity) |
- |
20000 |
|
Only for internal testing |
5.3.6.3(Rated breaking capacity) |
- |
10000 |
|
Only for internal testing |
5.3.7(Short-circuit characteristics) |
- |
5000 |
|
Only for internal testing |
5.3.7.1(Rated short-time withstand current) |
- |
2000 |
|
Only for internal testing |
5.3.7.2(Rated short-circuit making capacity) |
- |
5000 |
|
Only for internal testing |
5.3.7.4(Rated conditional short-circuit current) |
- |
10000 |
|
Only for internal testing |
5.4(Utilization category) |
- |
1000 |
|
Only for internal testing |
5.5(Control circuits) |
- |
2000 |
|
Only for internal testing |
5.6(Auxiliary circuits) |
- |
2000 |
|
Only for internal testing |
5.7(Relays and releases) |
- |
2000 |
|
Only for internal testing |
5.8(Co-ordination with short-circuit protective devices (SCPD)) |
- |
3000 |
|
Only for internal testing |
6.2.2(Marking) |
- |
2000 |
|
Only for internal testing |
6.3(Instructions for installation, operation and maintenance, decommissioning and dismantling) |
- |
2000 |
|
Only for internal testing |
8.1.1(General) |
- |
2000 |
|
Only for internal testing |
8.1.2.2(Glow wire testing) |
- |
16000 |
|
Only for internal testing |
8.1.7.1(General) |
- |
2000 |
|
Only for internal testing |
8.2.1(Operating conditions) |
- |
2000 |
|
Only for internal testing |
8.2.1.1(General) |
- |
2000 |
|
Only for internal testing |
8.2.1.2(Limits of operation of power operated equipment) |
- |
2000 |
|
Only for internal testing |
8.2.1.3(Limits of operation of under-voltage relays and releases) |
- |
5000 |
|
Only for internal testing |
8.2.1.4(Limits of operation of shunt releases) |
- |
5000 |
|
Only for internal testing |
8.2.2(Temperature-rise) |
- |
20000 |
|
Only for internal testing |
8.2.3(Dielectric properties) |
- |
20000 |
|
Only for internal testing |
8.2.3.2(Impulse withstand voltage) |
- |
10000 |
|
Only for internal testing |
8.2.3.3(Power-frequency or DC withstand voltage of the main, auxiliary and control circuits) |
- |
2000 |
|
Only for internal testing |
8.2.4(Ability to make and break under no-load, normal load and overload conditions) |
- |
2000 |
|
Only for internal testing |
8.2.4.1(Making and breaking capacities) |
- |
4000 |
|
Only for internal testing |
8.2.4.2(Operational performance) |
- |
20000 |
|
Only for internal testing |
8.2.4.3(Mechanical durability) |
- |
30000 |
|
Only for internal testing |
8.2.4.4(Electrical durability) |
- |
40000 |
|
Only for internal testing |
8.2.5(Ability to make, break or withstand short-circuit currents) |
- |
10000 |
|
Only for internal testing |
8.2.7(Additional performance requirements for equipment suitable for isolation) |
- |
10000 |
|
Only for internal testing |
8.2.8(Critical load current performance: DC equipment) |
- |
10000 |
|
Only for internal testing |
8.2.9(Overload requirements for equipment incorporating fuses) |
- |
20000 |
|
Only for internal testing |
9.1.3.2(Mechanical operation test) |
- |
30000 |
|
Only for internal testing |
9.1.3.3(Dielectric test) |
- |
10000 |
|
Only for internal testing |
9.1.4(Sampling tests) |
- |
5000 |
|
Only for internal testing |
9.1.5Special tests(Special tests) |
- |
10000 |
|
Only for internal testing |
9.2(Compliance with constructional requirements) |
- |
2000 |
|
Only for internal testing |
9.3.3.6(DC test current ripple) |
- |
2000 |
|
Only for internal testing |
9.3.4.2(Temperature-rise) |
- |
20000 |
|
Only for internal testing |
9.3.4.3(Test of dielectric properties) |
- |
20000 |
|
Only for internal testing |
9.3.4.4(Making and breaking capacities) |
- |
40000 |
|
Only for internal testing |
9.3.4.4.3(Characteristics of transient recovery voltage) |
- |
2000 |
|
Only for internal testing |
9.3.4.5(Dielectric verification) |
- |
8000 |
|
Only for internal testing |
9.3.4.6(Leakage current) |
- |
5000 |
|
Only for internal testing |
9.3.5.2(Operational performance test) |
- |
15000 |
|
Only for internal testing |
9.3.6.2(Short-time withstand current test) |
- |
10000 |
|
Only for internal testing |
9.3.6.3(Short-circuit making capacity test) |
- |
30000 |
|
Only for internal testing |
9.3.7.2(Circuit-breaker protected short-circuit withstand) |
- |
5000 |
|
Only for internal testing |
9.3.7.3(Fuse protected short-circuit withstand) |
- |
5000 |
|
Only for internal testing |
9.3.8.2(Overload test) |
- |
10000 |
|
Only for internal testing |
9.3.9.2(Determination of critical load current) |
- |
2000 |
|
Only for internal testing |
9.4(Electromagnetic compatibility tests) |
- |
2000 |
|
Only for internal testing |
9.5.2(Mechanical durability) |
- |
15000 |
|
Only for internal testing |
9.5.3(Electrical durability) |
- |
30000 |
|
Only for internal testing |
D.7.1.1(Ambient air temperature) |
- |
20000 |
|
Only for internal testing |
D.8.1.4(Clearances and creepage distances) |
- |
10000 |
|
Only for internal testing |
D.8.1.12(Degrees of protection of enclosed equipment) |
- |
30000 |
|
Only for internal testing |
D.9.3.10(Thermal cycling test) |
- |
1000 |
|
Only for internal testing |
D.9.3.11(Climatic test) |
- |
10000 |
|
Only for internal testing |
D.9.3.12(Temperature-rise verification with solar effects – Outdoor units only) |
- |
20000 |
|
Only for internal testing |
E.9.2(Current cycling test) |
- |
10000 |
|
Only for internal testing |
E.9.2.4(Temperature measurements) |
- |
20000 |
|
Only for internal testing |
E.9.3.1(Flexion test) |
- |
10000 |
|
Only for internal testing |
E.9.3.2(Pull-out test) |
- |
10000 |
|
Only for internal testing |
8.1.7.2(Additional constructional requirements) |
- |
2000 |
|
Only for internal testing |
8.1.9(Additional requirements for equipment provided with a neutral pol) |
- |
2000 |
|
Only for internal testing |
9.3.4.7(Temperature-rise verification) |
- |
15000 |
|
Only for internal testing |
9.3.4.8(Strength of actuator mechanism) |
- |
10000 |
|
Only for internal testing |
9.3.5.3(Dielectric verification) |
- |
10000 |
|
Only for internal testing |
9.3.5.5(Temperature-rise verification) |
- |
15000 |
|
Only for internal testing |
9.3.6.4(Dielectric verification) |
- |
10000 |
|
Only for internal testing |
9.3.6.6(Temperature-rise verification) |
- |
15000 |
|
Only for internal testing |
9.3.7.4(Dielectric verification) |
- |
10000 |
|
Only for internal testing |
9.3.7.6(Temperature-rise verification) |
- |
15000 |
|
Only for internal testing |
9.3.8.3(Dielectric verification) |
- |
10000 |
|
Only for internal testing |
9.3.8.5(Temperature-rise verification) |
- |
15000 |
|
Only for internal testing |
9.3.9.3(Critical load current performance) |
- |
2000 |
|
Only for internal testing |
9.3.5.4(Leakage current) |
- |
10000 |
|
Only for internal testing |
9.3.6.5(Leakage current) |
- |
10000 |
|
Only for internal testing |
9.3.7.5(Leakage current) |
- |
10000 |
|
Only for internal testing |
9.3.8.4(Leakage current) |
- |
10000 |
|
Only for internal testing |
9.4.2(Immunity) |
- |
2000 |
|
Only for internal testing |
9.4.3(Emission) |
- |
2000 |
|
Only for internal testing |
9.5.4(Damp heat, salt mist, vibration and shock) |
- |
10000 |
|
Only for internal testing |
7(Normal service, mounting and transport conditions) |
- |
1000 |
|
Only for internal testing |
9.1.3.2(Mechanical operation test) |
- |
10000 |
|
Only for internal testing |
|
05 Jun, 2028 |
- Included w.e.f 23.06.2025 Restricted only for Sequence I, II, V & VI. Excluding Cl. 8.3 (Electromagnetic compatibility (EMC)), Cl. 9.3.6 (short-circuit performance capability), Cl. 9.3.7 (conditional short-circuit current), Cl. 9.3.4 (Performance under short-circuit conditions), Cl. 9.4 (EMC tests), 9.3.9.2 (Determination of critical load current), 8.2.8 (Critical load current performance: DC equipment) |
789 |
BIS, Central Laboratory (CL)
| None
| IS 1538 (1993) |
Cast iron fittings for pressure pipes for water, gas and sewage - Specification (Third Revision) |
- |
- View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
5.1 (tensile strength) |
- |
|
|
|
6.1 (Brinell hardness tests) |
- |
|
|
|
8 (Hydrostatic Test) |
- |
|
|
|
9.1,Table 2 & 3 (DI) |
- |
|
|
|
9.1,Table 2 & 3 (P) |
- |
|
|
|
9.1,Table 2 & 3 (g) |
- |
|
|
|
9.1,Table 2 & 3 (h) |
- |
|
|
|
9.1,Table 2 & 3 (K) |
- |
|
|
|
9.1,Table 2 & 3 (L) |
- |
|
|
|
9.1,Table 2 & 3 (M) |
- |
|
|
|
9.1,Table 2 & 3 (N) |
- |
|
|
|
9.1,Table 2 & 3 (f) |
- |
|
|
|
9.1,Table 4 (D) |
- |
|
|
|
9.1,Table 4 (a) |
- |
|
|
|
9.1,Table 4 (b) |
- |
|
|
|
9.1,Table 4 (s) |
- |
|
|
|
9.1,Table 4 (r) |
- |
|
|
|
9.1,Table 5 (D) |
- |
|
|
|
9.1,Table 5 (g) |
- |
|
|
|
9.1,Table 5 (a) |
- |
|
|
|
9.1,Table 5 (b) |
- |
|
|
|
9.1,Table 5 (c) |
- |
|
|
|
9.1,Table 5 (f) |
- |
|
|
|
9.1,Table 5 (s) |
- |
|
|
|
9.1,Table 5 (C) |
- |
|
|
|
9.1,Table 5 (Holes No) |
- |
|
|
|
9.1,Table 5 (Holes diameter) |
- |
|
|
|
9.1,Table 6 (Diameterof Bolts) |
- |
|
|
|
9.1&11.1,Table 7,8&9 (e) |
- |
|
|
|
9.1&11.1,Table 7,8&9 (l) |
- |
|
|
|
9.1&11.1,Table 7,8&9 (Mass (Approx)) |
- |
|
|
|
9.1&11.1,Table 10 to13 (e) |
- |
|
|
|
9.1&11.1,Table 10 to13 (a) |
- |
|
|
|
9.1&11.1,Table 10 to13 (r) |
- |
|
|
|
9.1&11.1,Table 10 to13 (b) |
- |
|
|
|
9.1&11.1,Table 10 to13 (Mass (Approx)) |
- |
|
|
|
9.1&11.1,Table 14 (Nominal Diameter) |
- |
|
|
|
9.1&11.1,Table 14 (e1) |
- |
|
|
|
9.1&11.1,Table 14 (e) |
- |
|
|
|
9.1&11.1,Table 14 (l) |
- |
|
|
|
9.1&11.1,Table 14 (h) |
- |
|
|
|
9.1&11.1,Table 14 (Mass (Approx)) |
- |
|
|
|
9.1&11.1,Table 15 (e) |
- |
|
|
|
9.1&11.1,Table 15 (l) |
- |
|
|
|
9.1&11.1,Table 15 (Nominal Diameter) |
- |
|
|
|
9.1&11.1,Table 15 (e1) |
- |
|
|
|
9.1&11.1,Table 15 (k) |
- |
|
|
|
9.1&11.1,Table 15 (Mass (Approx)) |
- |
|
|
|
9.1&11.1,Table 16 (e) |
- |
|
|
|
9.1&11.1,Table 16 (l) |
- |
|
|
|
9.1&11.1,Table 16 (h) |
- |
|
|
|
9.1&11.1,Table 16 (Mass (Approx)) |
- |
|
|
|
9.1&11.1,Table 17 (e1) |
- |
|
|
|
9.1&11.1,Table 17 (l1) |
- |
|
|
|
9.1&11.1,Table 17 (Nominal Diameter) |
- |
|
|
|
9.1&11.1,Table 17 (e2) |
- |
|
|
|
9.1&11.1,Table 17 (l2) |
- |
|
|
|
9.1&11.1,Table 17 (l3) |
- |
|
|
|
9.1&11.1,Table 17 (l) |
- |
|
|
|
9.1&11.1,Table 17 (Mass) |
- |
|
|
|
9.1&11.1,Table 18 (a) |
- |
|
|
|
9.1&11.1,Table 18 (P) |
- |
|
|
|
9.1&11.1,Table 18 (Mass (Approx)) |
- |
|
|
|
9.1&11.1,Table 19 (DC) |
- |
|
|
|
9.1&11.1,Table 19 (e) |
- |
|
|
|
9.1&11.1,Table 19 (a) |
- |
|
|
|
9.1&11.1,Table 19 (l) |
- |
|
|
|
9.1&11.1,Table 19 (Mass (Approx)) |
- |
|
|
|
9.1&11.1,Table 20 (DI) |
- |
|
|
|
9.1&11.1,Table 20 (h) |
- |
|
|
|
9.1&11.1,Table 20 (Mass (Approx)) |
- |
|
|
|
9.1&11.1,Table 21 (e) |
- |
|
|
|
9.1&11.1,Table 21 (r) |
- |
|
|
|
9.1&11.1,Table 21 (a) |
- |
|
|
|
9.1&11.1,Table 21 (b) |
- |
|
|
|
9.1&11.1,Table 21 (Mass (Approx)) |
- |
|
|
|
9.1&11.1,Table 22 (e) |
- |
|
|
|
9.1&11.1,Table 22 (r) |
- |
|
|
|
9.1&11.1,Table 22 (a) |
- |
|
|
|
9.1&11.1,Table 22 (b) |
- |
|
|
|
9.1&11.1,Table 22 (c) |
- |
|
|
|
9.1&11.1,Table 22 (a) |
- |
|
|
|
9.1&11.1,Table 22 (f) |
- |
|
|
|
9.1&11.1,Table 22 (g) |
- |
|
|
|
12.1 to 12.7 (Coating ) |
- |
|
|
|
|
- |
- - |
790 |
Havells India Limited (Havells Research & Development Laboratory)
| 8187226
| IS/IEC 60947 : PART 3 (2020) |
Low-Voltage Switchgear and Controlgear: Part 3 Switches Disconnectors Switch-Disconnectors and Fuse-Combination Units |
Switches, Disconnectors, Switch- Disconnectors and Fuse-Combination Units |
2593000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
3.1(General) |
- |
0 |
|
Only for internal testing |
4(Classification) |
- |
10000 |
|
Only for internal testing |
5.3.2(Rated voltages) |
- |
0 |
|
Only for internal testing |
5.3.2.1(Rated operational voltage) |
- |
0 |
|
Only for internal testing |
5.3.2.2(Rated insulation voltage) |
- |
0 |
|
Only for internal testing |
5.3.2.3(Rated impulse withstand voltage) |
- |
0 |
|
Only for internal testing |
5.3.3(Currents) |
- |
0 |
|
Only for internal testing |
5.3.3.2(Conventional free air thermal current) |
- |
0 |
|
Only for internal testing |
5.3.3.3(Conventional enclosed thermal current) |
- |
0 |
|
Only for internal testing |
5.3.3.4(Rated operational current (Ie) or rated operational power) |
- |
0 |
|
Only for internal testing |
5.3.3.5(Rated uninterrupted current) |
- |
0 |
|
Only for internal testing |
5.3.4(Rated frequency) |
- |
0 |
|
Only for internal testing |
5.3.5(Rated duty) |
- |
0 |
|
Only for internal testing |
5.3.5.2(Eight-hour duty) |
- |
0 |
|
Only for internal testing |
5.3.5.3(Uninterrupted duty) |
- |
0 |
|
Only for internal testing |
5.3.6.1(Ability to withstand motor switching overload currents) |
- |
0 |
|
Only for internal testing |
5.3.6.2(Rated making capacity) |
- |
0 |
|
Only for internal testing |
5.3.6.3(Rated breaking capacity) |
- |
0 |
|
Only for internal testing |
5.3.7(Short-circuit characteristics) |
- |
0 |
|
Only for internal testing |
5.3.7.1(Rated short-time withstand current) |
- |
0 |
|
Only for internal testing |
5.3.7.2(Rated short-circuit making capacity) |
- |
0 |
|
Only for internal testing |
5.3.7.4(Rated conditional short-circuit current) |
- |
0 |
|
Only for internal testing |
5.4(Utilization category) |
- |
0 |
|
Only for internal testing |
5.5(Control circuits) |
- |
0 |
|
Only for internal testing |
5.6(Auxiliary circuits) |
- |
0 |
|
Only for internal testing |
5.7(Relays and releases) |
- |
0 |
|
Only for internal testing |
5.8(Co-ordination with short-circuit protective devices (SCPD)) |
- |
0 |
|
Only for internal testing |
6.2.2(Marking) |
- |
0 |
|
Only for internal testing |
6.3(Instructions for installation, operation and maintenance, decommissioning and dismantling) |
- |
0 |
|
Only for internal testing |
7(Normal service, mounting and transport conditions) |
- |
0 |
|
Only for internal testing |
8.1.1(General) |
- |
0 |
|
Only for internal testing |
8.1.2.2(Glow wire testing) |
- |
60000 |
|
Only for internal testing |
8.1.7.1(General) |
- |
0 |
|
Only for internal testing |
8.2.1(Operating conditions) |
- |
20000 |
|
Only for internal testing |
8.2.1.1(General) |
- |
0 |
|
Only for internal testing |
8.2.2(Temperature-rise) |
- |
25000 |
|
Only for internal testing |
8.2.3(Dielectric properties) |
- |
20000 |
|
Only for internal testing |
8.2.3.2(Impulse withstand voltage) |
- |
15000 |
|
Only for internal testing |
8.2.3.3(Power-frequency or DC withstand voltage of the main, auxiliary and control circuits) |
- |
0 |
|
Only for internal testing |
8.2.4(Ability to make and break under no-load, normal load and overload conditions) |
- |
50000 |
|
Only for internal testing |
8.2.4.1(Making and breaking capacities) |
- |
50000 |
|
Only for internal testing |
8.2.4.2(Operational performance) |
- |
100000 |
|
Only for internal testing |
8.2.4.3(Mechanical durability) |
- |
90000 |
|
Only for internal testing |
8.2.4.4(Electrical durability) |
- |
90000 |
|
Only for internal testing |
8.2.5(Ability to make, break or withstand short-circuit currents) |
- |
200000 |
|
Only for internal testing as per each rating |
8.2.7(Additional performance requirements for equipment suitable for isolation) |
- |
0 |
|
Only for internal testing |
8.2.9(Overload requirements for equipment incorporating fuses) |
- |
0 |
|
Only for internal testing |
9.1.3.2(Mechanical operation test) |
- |
90000 |
|
Only for internal testing |
9.1.3.3(Dielectric test) |
- |
65000 |
|
Only for internal testing |
9.1.5Special tests(Special tests) |
- |
100000 |
|
Only for internal testing |
9.2(Compliance with constructional requirements) |
- |
40000 |
|
Only for internal testing |
9.3.4.2(Temperature-rise) |
- |
25000 |
|
Only for internal testing |
9.3.4.3(Test of dielectric properties) |
- |
65000 |
|
Only for internal testing |
9.3.4.4(Making and breaking capacities) |
- |
60000 |
|
Only for internal testing |
9.3.4.4.3(Characteristics of transient recovery voltage) |
- |
0 |
|
Only for internal testing |
9.3.4.5(Dielectric verification) |
- |
28000 |
|
Only for internal testing |
9.3.4.6(Leakage current) |
- |
25000 |
|
Only for internal testing |
9.3.5.2(Operational performance test) |
- |
50000 |
|
Only for internal testing |
9.3.6.2(Short-time withstand current test) |
- |
200000 |
|
Only for internal testing as per each rating |
9.3.6.3(Short-circuit making capacity test) |
- |
200000 |
|
Only for internal testing as per each rating |
9.3.7.3(Fuse protected short-circuit withstand) |
- |
200000 |
|
Only for internal testing as per each rating |
9.3.8.2(Overload test) |
- |
60000 |
|
Only for internal testing |
9.3.9.2(Determination of critical load current) |
- |
50000 |
|
Only for internal testing |
9.5.2(Mechanical durability) |
- |
40000 |
|
Only for internal testing |
9.5.3(Electrical durability) |
- |
70000 |
|
Only for internal testing |
8.1.7.2(Additional constructional requirements) |
- |
40000 |
|
Only for internal testing |
8.1.9(Additional requirements for equipment provided with a neutral pol) |
- |
40000 |
|
Only for internal testing |
9.3.4.7(Temperature-rise verification) |
- |
25000 |
|
Only for internal testing |
9.3.4.8(Strength of actuator mechanism) |
- |
20000 |
|
Only for internal testing |
9.3.5.3(Dielectric verification) |
- |
30000 |
|
Only for internal testing |
9.3.5.5(Temperature-rise verification) |
- |
25000 |
|
Only for internal testing |
9.3.6.4(Dielectric verification) |
- |
30000 |
|
Only for internal testing |
9.3.6.6(Temperature-rise verification) |
- |
25000 |
|
Only for internal testing |
9.3.7.4(Dielectric verification) |
- |
30000 |
|
Only for internal testing |
9.3.7.6(Temperature-rise verification) |
- |
25000 |
|
Only for internal testing |
9.3.8.3(Dielectric verification) |
- |
30000 |
|
Only for internal testing |
9.3.8.5(Temperature-rise verification) |
- |
25000 |
|
Only for internal testing |
9.3.5.4(Leakage current) |
- |
25000 |
|
Only for internal testing |
9.3.6.5(Leakage current) |
- |
25000 |
|
Only for internal testing |
9.3.7.5(Leakage current) |
- |
25000 |
|
Only for internal testing |
9.3.8.4(Leakage current) |
- |
25000 |
|
Only for internal testing |
9.1.3.2(Mechanical operation test) |
- |
70000 |
|
Only for internal testing |
|
07 Aug, 2028 |
- - |
791 |
CIPET. MYSURU
| 6113734
| IS 13487 (1992) |
Irrigation equipment - Emitters - Specification |
- |
6150 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
7.1(Construction and workmanship) |
- |
225 |
|
Construction and workmanship |
7.2(Flow path in emitters) |
- |
225 |
|
Flow path in the emitter |
7.3.1(Resistance to Hydrostatic pressure) |
- |
750 |
|
Resistance to Hydrostatic pressure |
7.3.2(Resistance to Hydrostatic pressure) |
- |
750 |
|
Resistance to Hydrostatic pressure |
7.4.1(Emitter Pull Out In-line emitters) |
- |
750 |
|
Emitter Pull Out In-line emitters |
8.1.2(Uniformity of Emission Rate Unregulated emitters) |
- |
750 |
|
Uniformity of Emission Rate Unregulated emitters |
8.1.3(Uniformity of Emission Rate Regulated emitters) |
- |
749.98 |
|
Uniformity of Emission Rate Regulated emitters |
8.2.2(Emission rate as a function of inlet pressure Unregulated emitters) |
- |
750 |
|
Emission rate as a function of inlet pressure Unregulated emitters |
8.2.3(Emission rate as a function of inlet pressure Regulated emitters) |
- |
750 |
|
Emission rate as a function of inlet pressure Regulated emitters |
8.3(Determination of Emitter Exponent) |
- |
450 |
|
Determination of Emitter Exponent |
|
31 Dec, 2026 |
- - |
792 |
CIPET. MYSURU
| 6113734
| IS 13488 (2008) |
Irrigation equipment - Emitting pipe systems - Specification (First Revision) |
CATEGORY A/B/ |
14532 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
5.1.2 (Ref. Cl 4.1.a of IS 12786 : 1989)(Potyethylene - higher olefins constituent ) |
- |
1500 |
|
Polyethylene - Material |
5.1.2 (Ref. Cl 4.1.c.ii of IS 12786 : 1989)(Toluene extract - Annex A of IS 12786:1989) |
- |
750.01 |
|
Toluene extract - Annex A of IS 12786:1989 |
5.1.2 (Ref. Cl 4.1.c.iii of IS 12786 : 1989)(Volatile matter - Annex B of IS 12786:1989) |
- |
525 |
|
Volatile matter - Annex B of IS 12786:1989 |
5.1.2 (Ref. Cl 4.1.c & 4.2.a of IS 12786 : 1989)(Carbon Black content - IS 2530 : 1963) |
- |
694 |
|
Carbon Black content - IS 2530: 1963 |
5.1.2 (Ref. Cl 4.2.b of IS 12786 : 1989)(The dispersion of Carbon Black content shall be satisfactory - IS 2530 : 1963) |
- |
525 |
|
CBD |
6.2.2(Fittings) |
- |
225 |
|
Visual |
6.3(General) |
- |
225 |
|
Visual |
8.1.2(Uniformity of Emission Rate for Unregulated Emitting Pipes) |
- |
750 |
|
Uniformity of Emission Rate for Unregulated Emitting Pipes |
8.1.3(Uniformity of Emission Rate for Regulated Emitting Pipes) |
- |
749.98 |
|
Uniformity of Emission Rate for Regulated Emitting Pipes |
8.2(Emission Rate of Emitting Unit as a Function of Inlet Pressure) |
- |
750 |
|
Emission Rate of Emitting Unit as a Function of Inlet Pressure |
8.3.1(Wall Thickness ofEmitting Pipe) |
- |
188 |
|
Wall Thickness ofEmitting Pipe |
8.3.2(Inside Diameter ofEmitting Pipe) |
- |
188 |
|
Inside Diameter ofEmitting Pipe |
8.3.3(Flow Paths in Emitting Unit) |
- |
188 |
|
Flow Paths in Emitting Unit |
8.3.4(Spacing ofEmitter Units) |
- |
300 |
|
Spacing ofEmitter Units |
8.4(Resistance of Emitting Pipes to Hydrostatic
Pressure) |
- |
750 |
|
Resistance of Emitting Pipes to Hydrostatic
Pressure |
8.4.2(Resistance to Hydrostatic Pressure at Elevated Temperature) |
- |
750 |
|
Resistance to Hydrostatic Pressure at Elevated Temperature |
8.5(Resistance to Tension at Elevated Temperature) |
- |
1200 |
|
resistance to Tension at Elevated Temperature |
8.6(Resistance to Pull Out of Joints Between Fitting and Emitting
IS 13479) |
- |
300 |
|
Resistance to Pull Out of Joints Between Fitting and Emitting
IS 13479 |
8.7.1(Acceptance Test) |
- |
900 |
|
Acceptance Test |
8.7.2(Type Test) |
- |
1200 |
|
Type Test |
8.8(Determination of Emitting Unit Exponen) |
- |
450 |
|
Determination of Emitting Unit Exponenent |
9.1(Non-regulated Emitting Pipe) |
- |
225 |
|
non-regulated Emitting Pipe |
9.2(Regulated Emitting Pipe) |
- |
225.02 |
|
Regulated Emitting Pipe |
8.2(Emission Rate of Emitting Unit as a Function
of Inlet Pressure) |
- |
1000 |
|
- |
|
31 Dec, 2026 |
- - |
793 |
CIPET. MYSURU
| 6113734
| IS 13592 (2013) |
Unplasticized Polyvinyl Chloride (PVC-U) Pipes for Soil and Waste Discharge System Inside and Outside Buiildings Including Ventilation and Rainwater System |
- |
15400 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
14(Marking) |
- |
0 |
|
- |
Cl6.3(The composition shall be based on PVC resin
having a K-value of 64 or greater when tested in
accordance with IS 4669) |
- |
825 |
|
K value |
Cl.7.1(Mean outside diameter, outside diameter at any point
for Type A and Type B pipes
manufactured plain or with socket shall be as given in
Table 1. Dimensions shall be measured according to
the method given in IS 12235 (Part 1).) |
- |
375 |
|
Dimensions |
Cl.7.1( outside diameter at any point
for Type A and Type B pipes
manufactured plain or with socket shall be as given in
Table 1. Dimensions shall be measured according to
the method given in IS 12235 (Part 1).) |
- |
0 |
|
Dimensions |
Cl.7.1( wall thickness at any point
for Type A and Type B pipes
manufactured plain or with socket shall be as given in
Table 1. Dimensions shall be measured according to
the method given in IS 12235 (Part 1).) |
- |
0 |
|
Dimensions |
Cl.7.3.1(Minimum wall thickness of socket on pipes shall
be as given in Table 2 read with Fig. 2 and Fig. 3.) |
- |
0 |
|
Dimensions |
Cl.7.3.2(Dimensions of sockets for solvent cementing and
grooved sockets of pipes shall be as given in Tables 3
and 4 respectively, read with Fig. 2 and 3.) |
- |
0 |
|
Dimensions |
Cl.8.1(The internal and external surface of the pipes shall be
smooth and clean, and free from grooving and other
defects. The end shall be clearly cut and shall be square
with the axis of the pipe. The end may be chamfered
on the plain side.) |
- |
225 |
|
Visual Appearance |
Cl8.3(This test shall be carried out for socket end pipes only.
When tested by the method described in IS 12235
(Part 6), the test specimens shall not show blisters,
excessive delamination or cracking or signs of weld
line splitting.) |
- |
525 |
|
Stress Relief test |
Cl.8.2(When tested by the method described in IS 12235
(Part 5), a length of pipe sample of 200 ± 20 mm shall
not alter in length by more than 5 percent. In the case
of socket ended pipes, this test shall be carried out on
the plain portion of pipe taken at least 100 mm away
from the root of the socket.) |
- |
825 |
|
Reversion |
Cl.8.4(When determined in accordance with IS 12235 (Part 2),
the vicat softening temperature of the specimen shall
not be less than 79°C.) |
- |
8025 |
|
VST |
Cl.8.5(After the required
period of exposure, the tensile strengths of two samples when tested as per IS 12235 (Part 13) shall not show
difference of more than 20 percent of their initial tensile
strengths) |
- |
3500 |
|
Effect Of sunlight |
Cl. 9, IS 12235 Part 7(Resistance to Sulphuric Acid) |
- |
2000 |
|
Resistance to Sulphuric Acid |
Cl.10.1(When tested by method prescribed in IS 12235 (Part 9),the pipe shall have a true impact rate of not more than
10 percent. Mass of striker and height of fall shall be
as per Annex A.) |
- |
1125 |
|
Res to External Blow |
Cl.10.2(When determined in accordance with the method
described in IS 12235 (Part 13), the tensile strength at
break shall not be less than 45 MPa.) |
- |
2450 |
|
Tensile Before & After Exposure |
Cl.10.3(The axial shrinkage shall not exceed 2 percent when
determined in accordance with Annex B.) |
- |
825 |
|
Axial Shrinkage |
Cl.11.(Jointing of solvent
cementing joints is to be carried out using solvent
conforming to IS 14182.
Apply a pressure of 0.05 MPa for a period of 15 min
and there should be no leakage at any joint.) |
- |
750 |
|
Water tightness of joints |
Cl. 12, IS 12235 Part 11(Resistance to Di-Chloro-Methane) |
- |
750 |
|
Resistance to DCM |
8.6(Effect on Water Test) |
- |
2250 |
|
EOW |
|
31 Dec, 2026 |
- - |
794 |
CIPET. MYSURU
| 6113734
| IS 4985 (2021) |
UNPLASTICIZED PVC PIPES FOR POTABLE WATER SUPPLIES SPECIFICATION Fourth Revision |
up to 400mm |
23656 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
11.2(Resistance to External Blows at 0°C) |
- |
1000 |
|
Resistance to External Blows at 0°C |
11.1-Table 6(MECHANICAL PROPERTIES-Hydrostatic Pressure Test (Acceptance Test)) |
- |
637.50 |
|
(Acceptance Test) |
11.1-Table 7(MECHANICAL PROPERTIES-Hydrostatic Pressure Test (Type Test)-for Integral Sealing Ring Sockets) |
- |
637.50 |
|
MECHANICAL PROPERTIES-Hydrostatic Pressure Test (Type Test)-for Integral Sealing Ring Sockets |
11.1.1(MECHANICAL PROPERTIES-Hydrostatic Pressure Test (Acceptance Test)-for Plumbing pipes) |
- |
637.50 |
|
MECHANICAL PROPERTIES-Hydrostatic Pressure Test (Acceptance Test)-for Plumbing pipes |
10.6(PHYSICAL AND CHEMICAL CHARACTERISTICS- Density) |
- |
525 |
|
Density |
10.5(PHYSICAL AND CHEMICAL CHARACTERISTICS- Vicat Softening Temperature) |
- |
825 |
|
Vicat Softening Temperature |
10.4(PHYSICAL AND CHEMICAL CHARACTERISTICS- Reversion Test) |
- |
825 |
|
Reversion Test |
10.2(PHYSICAL AND CHEMICAL CHARACTERISTICS-Opacity) |
- |
575 |
|
Opacity |
10.1(PHYSICAL AND CHEMICAL CHARACTERISTICS-Visual Appearance) |
- |
225 |
|
-Visual Appearance |
9.1(PIPE ENDS) |
- |
0 |
|
PIPE ENDS |
8(SEALING RINGS) |
- |
0 |
|
SEALING RINGS |
10.7(Sulphated Ash Content) |
- |
900 |
|
Sulphated Ash Content |
7(DIMENSIONS-PIPE-Nominal Diameter) |
- |
500 |
|
DIMENSIONS-PIPE- All |
7.1.1.1(DIMENSIONS-PIPE-Mean O.D. (Minimum)) |
- |
0 |
|
Mean O.D. (Minimum) |
7.1.1.2(DIMENSIONS-PIPE-O.D. at any Point (Minimum)) |
- |
0 |
|
DIMENSIONS-PIPE-O.D. at any Point (Minimum) |
7.1.1.2(DIMENSIONS-PIPE-Ovality (Maximum)) |
- |
0 |
|
DIMENSIONS-PIPE-Ovality (Maximum) |
7.1.2.1(DIMENSIONS-PIPE-Thickness(Minimum)) |
- |
0 |
|
DIMENSIONS-PIPE-Thickness(Minimum) |
7.1.2.1(DIMENSIONS-PIPE-Average Thickness) |
- |
0 |
|
DIMENSIONS-PIPE-Average Thickness |
7.2.1(DIMENSIONS-Socket) |
- |
0 |
|
DIMENSIONS-Socket |
6.1.1(VCM Content) |
- |
2250 |
|
VCM Content |
6.1.2(PVC Resin) |
- |
825 |
|
K Value |
10.3(Effect on Water Test) |
- |
2250 |
|
Effect on Water Test |
10.1(Colour) |
- |
225 |
|
Colour |
10.1(Surface Finish) |
- |
0 |
|
Surface Finish |
7.2.1.1 Table3(Angle of taper (Note-1)) |
- |
0 |
|
Angle of taper (Note-1) |
|
31 Dec, 2026 |
- - |
795 |
CIPET. MYSURU
| 6113734
| IS 17425 (2020) |
Irrigation Equipment - Quick Coupled Polyethylene Pipes and Fittings for Sprinkler Irrigation Systems - Specification |
Size |
42290 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
Cl.4.1.3(Den sity Test) |
- |
1200 |
|
Density Test |
4.1.3, Table 1,(ii)(Melt flow rate) |
- |
900 |
|
Melt flow rate |
6.1(Thermal Stability (OIT)) |
- |
1650 |
|
Thermal Stability (OIT) |
4.1.1 (Table-1)(Volatile Matter) |
- |
900 |
|
Volatile Matter |
4.1.3, Table 1,(vi)(Minimum tensile strength at yield) |
- |
1975 |
|
tensile strenght at yield |
4.1.3, Table 1,(vii)(Minimum elongation at break) |
- |
0 |
|
Included |
Cl.4.1.4(Carbon Black Content) |
- |
694 |
|
Carbon Black Content |
4.1.4(The Carbon Content and Dispersion) |
- |
1219 |
|
Carbon Content and Dispersion |
5(Dimensions of pipe - i) Outside diameter) |
- |
0 |
|
included |
5(Dimensions of pipe - ii) Wall thickness minimum) |
- |
375 |
|
Dimensions of pipe - all dimensions |
6(Visual Appearance) |
- |
225 |
|
Visual Appearance |
7.1(Hydraulic Characteristics - Quality test) |
- |
3000 |
|
Hydraulic Characteristics - Quality test |
7.1(Hydraulic Characteristics - Acceptance test) |
- |
1200 |
|
Hydraulic Characteristics - Acceptance test |
Cl.7.1.3(Reversion Test) |
- |
825.01 |
|
Reversion Test |
7.1.4(Tensile strength & elongation) |
- |
975 |
|
Tensile strength & elongation |
Cl.7.1.5(Fusion Compatibility) |
- |
1200 |
|
Fusion Compatibility |
Cl.7.1.6(Corrected Density) |
- |
1200 |
|
Corrected Density |
Cl.7.1.7(MFR Test) |
- |
900 |
|
MFR Test |
Cl.6.2.L(Wall Thickness) |
- |
0 |
|
Wall Thickness |
Cl.6.2.4(Workmanship and Appearance) |
- |
225.01 |
|
Workmanship and Appearance |
6.2.5(Holding attachment for coupler parts) |
- |
0 |
|
Holding attachment for coupler parts |
6.2.6(Rubber Ring Hardness Shore – A (Before Ageing)) |
- |
375 |
|
Rubber Ring Hardness Shore – A (Before Ageing) |
7.2.1(Leakage test 1hour / 27°C) |
- |
638 |
|
Leakage test 1hour |
7.2.2(Hydraulic Proof test 1hour / 27°C) |
- |
638.01 |
|
Hydraulic Proof test 1hour |
7.2.3((a) Acceptance Test (48 hrs) / 80˚ C) |
- |
1200 |
|
Acceptance Test (48 hrs) |
7.2.3((b) Type test ( 165 hrs) / 80˚ C) |
- |
3000 |
|
Type test |
4.1.5(Carbon Black Specification) |
- |
3750 |
|
Density, Toluene ex, Volatile matt, ash content |
|
31 Dec, 2026 |
- - |
796 |
CIPET. MYSURU
| 6113734
| IS 12818 (2010) |
Unplasticized polyvinyl chloride (Pvc - U) screen and casing pipes for bore/tubewells - Specification (Second Revision) |
- |
11808 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
9.6(Vicat Softening Temperature
IS 12235 (Part 2).) |
- |
825 |
|
VST |
9.5(Tensile Strength
IS 12235(Part 13)) |
- |
1325 |
|
Tensile Strength
IS 12235(Part 13) |
9.4 and Table 14(Resistance to External Blows at 0 ?C
IS 12235 (Part 9)) |
- |
1125 |
|
Resistance to External Blows at 0 ?C
IS 12235 (Part 9) |
9.3(Density
IS 12235 (Part 14)) |
- |
375 |
|
Density
IS 12235 (Part 14) |
9.2(Internal Diameter) |
- |
262.50 |
|
Internal Diameter |
9.1( Visual Appearance) |
- |
225 |
|
Visual Appearance |
8.4.1 and Table 13
Fig 3B & 4B(Dimensions of sealing elements) |
- |
187.5 |
|
Dimensions of sealing elements |
8.4(Sealing rings - Hardness) |
- |
281.25 |
|
Sealing rings - Hardness |
8.1 to 8.3 and Table 11 &12
Fig 3A & 4A(THREADING OF SCREEN ANDCASING PIPES.
IS 554.) |
- |
187.5 |
|
THREADING OF SCREEN ANDCASING PIPES.
IS 554. |
7.4 Table 8 & 9
Fig 1(Effective length, l2) |
- |
750 |
|
Effective length, l2 |
7.2 and Table 5, 6 & 7
Fig 1B(Wall thickness, Max) |
- |
0 |
|
Wall thickness, Max included |
7.2 and Table 5, 6 & 7
Fig 1B(Wall thickness, Min) |
- |
0 |
|
Wall thickness, Min included in dim |
7.2 and Table 5, 6 & 7
Fig 1B(Mean Outer Diameter over Connection) |
- |
0 |
|
Mean Outer Diameter over Connection included |
7.1 and Table 1, 2, 3, & 4
Fig 1A & 1B(Outer Diameter at any point ) |
- |
0 |
|
Outer Diameter at any point included |
7.2 and Table 5, 6 & 7
Fig 1B(DIMENSIONS - Casing Pipes) |
- |
0 |
|
DIMENSIONS - Casing Pipes included |
4.1.2 (Ref. Cl 11 of IS 4669)(Composition -Sulphated ash content ) |
- |
714.5 |
|
EOW, Raw material |
9.7(Effect on Water
a) Lead (first extraction)
b) Lead (Third extraction)
c) Dialkyl Tin C4 & higher homologues measured as Tin (Third extraction)
d) Cadmium (All three extracts)
e) Mercury (All three extracts)
f) Other Toxic Substances
) |
- |
2250 |
|
- |
4.1.2(K-Value as per IS-4669) |
- |
825 |
|
- |
4.1.1
(VCM Content as per IS 10151 (Annex A)) |
- |
2250 |
|
- |
5(COLOUR) |
- |
225 |
|
- |
|
31 Dec, 2026 |
- - |
797 |
CIPET. MYSURU
| 6113734
| IS 4984 (2016) |
Polyethylene pipes for water supply - Specification (Fifth Revision) |
upto 400mm diameter |
38275 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
5.2(Density) |
- |
525 |
|
Density |
5.2(MFI @ 1900C/5.0 Kg) |
- |
825 |
|
MFI |
Table-2 (iii, iv)(Thermal Stability (Oxidation Induction Time), Volatile Matter) |
- |
1650 |
|
Oxidation Induction Time |
5.2(Volatile matter Content) |
- |
525 |
|
Volatile matter Content |
6.2(Colour) |
- |
225 |
|
Colour |
6.2.1(6.1.1 Identification Stripes) |
- |
187.5 |
|
6.1.1 Identification Stripes |
7.1(Visual Appearance) |
- |
225 |
|
VA |
7.4 table -3 & 4(6.1 Dimensions) |
- |
375 |
|
6.1 Dimensions |
6.1.4(PIPE DESCRIPTION) |
- |
0.0 |
|
PIPE DESCRIPTION |
8,/8.1/8.1.1 table-5(PERFORMANCE REQUIREMENTS / Hydraulic Characteristics/ Internal Pressure Creep Rupture Test of Pipe) |
- |
16050 |
|
PERFORMANCE REQUIREMENTS / Hydraulic Characteristics/ Internal Pressure Creep Rupture Test of Pipe |
8.2(Longitudinal Reversion Test) |
- |
725 |
|
Reversion Test |
Cl 8.3(Carbon Black Content) |
- |
694 |
|
CBC |
Clause 8.3(Carbon Black Dispersion) |
- |
525 |
|
CBD |
8.4( Melt Flow Rate) |
- |
825 |
|
Melt Flow Rate |
8.5 (Oxidation Induction Time) |
- |
1650 |
|
Oxidation Induction Time |
6, 6.1(PIPE DESCRIPTION) |
- |
225 |
|
PIPE DESCRIPTION |
6, 6.1.1(PIPE DESCRIPTION) |
- |
0 |
|
PIPE DESCRIPTION |
6, 6.1.2(PIPE DESCRIPTION) |
- |
0 |
|
PIPE DESCRIPTION |
6.1.3 (PIPE DESCRIPTION) |
- |
0 |
|
PIPE DESCRIPTION |
7.2(Length) |
- |
0 |
|
Length |
7.4.1.2(Ovality) |
- |
0 |
|
Ovality |
8.1.2 table -5(Internal Pressure Creep Rupture Test of Pipe Joints) |
- |
1200 |
|
Internal Pressure Creep Rupture Test of Pipe Joints |
8.7(Density) |
- |
1000 |
|
Density |
8.8(Tensile Strength for Butt-fusion) |
- |
1325 |
|
Tensile Strength for Butt-fusion |
8.9 table-6(Elongation at Break) |
- |
1325 |
|
Elongation at Break |
8.10(Slow Crack Growth Rate) |
- |
4625 |
|
Slow Crack Growth Rate |
Clause 8.6(Overall migration (stimulate)) |
- |
1275 |
|
Overall Mig |
5.3 (a)(Carbon Black Master Batch) |
- |
693.75 |
|
Carbon black content |
5.3(b)(Carbon Black Master Batch) |
- |
525 |
|
Carbon black dispersion |
5.3(c)(Carbon Black Master Batch) |
- |
1650 |
|
Thermal Stability (Oxidation Induction Time) |
5.3(d)(Carbon Black Master Batch) |
- |
525 |
|
Volatile matter |
5.3(e)(Carbon Black Master Batch) |
- |
0 |
|
Water content |
|
31 Dec, 2026 |
- - |
798 |
BIS, Central Laboratory (CL)
| None
| IS 2508 (2024) |
Polyethylene Films and Sheets â Specification (Fourth Revision) |
- |
- View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
5.2.1.1/ Table-1,2,3 &4 (Nominal Thickness, Annex C,) |
- |
|
|
|
5.2.1.2 (Nominal Width) |
- |
|
|
|
5.2.1.1/ Table-1,2,3 &4 (Nominal Thickness, Annex C,) |
- |
|
|
|
|
- |
- - |
799 |
CIPET, Lucknow
| 9102534
| IS 2508 (2024) |
Polyethylene Films and Sheets â Specification (Fourth Revision) |
- |
16731.00 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
5.1.4 Sl No. (i) of Table 1, Table 2, Table 3 & Table 4.(Density - IS 13360 : Part 3 : Sec 10 : 2021) |
- |
500 |
|
- |
5.1.6(Black Film- Carbon black - IS 2508:2024) |
- |
750 |
|
- |
5.1.6(Ash content - IS 2508: 2024) |
- |
1200 |
|
- |
5.1.6(carbon black dispersion - IS 2530: 1963) |
- |
500 |
|
- |
5.1.1(Appearance) |
- |
500 |
|
- |
5.1.2(Film Form) |
- |
500 |
|
- |
5.1.3(Odour) |
- |
500 |
|
- |
5.1.5(Melt Flow Index- IS 13360 : Part 4 : Sec 1 : subsec 1 or IS 13360 : Part 4 : Sec 1 : subsec 2) |
- |
1100 |
|
- |
5.2.1.1/ Table-1,2,3 &4(Nominal Thickness, Annex C,) |
- |
500 |
|
- |
5.2.1.2(Nominal Width) |
- |
500 |
|
- |
6, Type 1 (LDPE/LLDPE) /Table-1("Tensile strength at break-Machine direction, IS 13360 (Part 5/Sec 1) and
IS 13360 (Part 5/ Sec 3)") |
- |
1800 |
|
- |
6/Table-1("Tensile strength at break-Transverse direction, IS 13360 (Part 5/Sec 1) and
IS 13360 (Part 5/ Sec 3)") |
- |
1800 |
|
- |
6/Table-1("Elongation % at break, -Machine direction,IS 13360 (Part 5/Sec 1) and
IS 13360 (Part 5/ Sec 3)") |
- |
0 |
|
- |
6/Table-1("Elongation % at break, -Transverse direction,IS 13360 (Part 5/Sec 1) and
IS 13360 (Part 5/ Sec 3)") |
- |
0 |
|
- |
6/Table-1("Ageing test at (70 ± 1) ºC for 7 days-Machine Direction, IS 7016 (Part 8)
followed by IS 13360 (Part 5/Sec 1) and IS 13360 (Part 5/Sec 3)") |
- |
4200 |
|
- |
6/Table-1("Ageing test at (70 ± 1) ºC for 7 days- Transverse Direction, IS 7016 (Part 8)
followed by IS 13360 (Part 5/Sec 1) and IS 13360 (Part 5/Sec 3)") |
- |
1800 |
|
- |
6/Table-1(Dart impact strength,Method B of IS 13360 (Part 5/Sec 6)) |
- |
850 |
|
- |
6/Table-1(Tear resistance -Machine direction, IS 13360 (Part 5/Sec 23)) |
- |
1600 |
|
- |
6/Table-1(Tear resistance-Transverse direction, IS 13360 (Part 5/Sec 23)) |
- |
1600 |
|
- |
" 7, Type 2 (HDPE/PE) /Table-2"("Tensile strength at break-Machine direction, IS 13360 (Part 5/Sec 1) and
IS 13360 (Part 5/ Sec 3)") |
- |
1800 |
|
- |
" 7/Table-2"("Tensile strength at break-Transverse direction, IS 13360 (Part 5/Sec 1) and
IS 13360 (Part 5/ Sec 3)") |
- |
1800 |
|
- |
" 7/Table-2"("Elongation % at break, -Machine direction,IS 13360 (Part 5/Sec 1) and
IS 13360 (Part 5/ Sec 3)") |
- |
0 |
|
- |
" 7/Table-2"("Elongation % at break, -Transverse direction,IS 13360 (Part 5/Sec 1) and
IS 13360 (Part 5/ Sec 3)") |
- |
0 |
|
- |
" 7/Table-2"("Ageing test at (70 ± 1) ºC for 7 days-Machine Direction, IS 7016 (Part 8)
followed by IS 13360 (Part 5/Sec 1) and IS 13360 (Part 5/Sec 3)") |
- |
4200 |
|
- |
" 7/Table-2"("Ageing test at (70 ± 1) ºC for 7 days- Transverse Direction, IS 7016 (Part 8)
followed by IS 13360 (Part 5/Sec 1) and IS 13360 (Part 5/Sec 3)") |
- |
1800 |
|
- |
" 7/Table-2"(Dart impact strength,Method B of IS 13360 (Part 5/Sec 6)) |
- |
850 |
|
- |
8, Type 3 (LDPE/LLDPE, PE) /Table-3("Average Tensile Break strength- Machine Direction, IS 13360 (Part 5/Sec 1) and
IS 13360 (Part 5/Sec 3)") |
- |
1800 |
|
- |
8/Table-3("Average Tensile Break strength- Transverse Direction, IS 13360 (Part 5/Sec 1) and
IS 13360 (Part 5/Sec 3)") |
- |
1300 |
|
- |
8/Table-3("Average Tensile Break Elongation %-Machine Direction, IS 13360 (Part 5/Sec 1) and
IS 13360 (Part 5/Sec 3)") |
- |
0 |
|
- |
8/Table-3("Average Tensile Break Elongation %-Transverse Direction, IS 13360 (Part 5/Sec 1) and
IS 13360 (Part 5/Sec 3)") |
- |
0 |
|
- |
8/Table-3(Average Tear resistance, IS 2508: 2024 Annex-D) |
- |
1600 |
|
- |
8/Table-3(Average Puncture resistance, IS 2508: 2024 Annex-E) |
- |
1100 |
|
- |
9, Type 4 (HDPE/PE) /Table-4("Average Yield strength- Machine Direction, IS 13360 (Part 5/Sec 1) and
IS 13360 (Part 5/Sec 3)") |
- |
1800 |
|
- |
9/Table-4("Average Yield strength- Transverse Direction, IS 13360 (Part 5/Sec 1) and
IS 13360 (Part 5/Sec 3)") |
- |
1300 |
|
- |
9/Table-4("Average Tensile Break strength- Machine Direction, IS 13360 (Part 5/Sec 1) and
IS 13360 (Part 5/Sec 3)") |
- |
1300 |
|
- |
9/Table-4("Average Tensile Break strength- Transverse Direction, IS 13360 (Part 5/Sec 1) and
IS 13360 (Part 5/Sec 3)") |
- |
1300 |
|
- |
9/Table-4("Average Tensile yield Elongation %-Machine Direction, IS 13360 (Part 5/Sec 1) and
IS 13360 (Part 5/Sec 3)") |
- |
0 |
|
- |
9/Table-4("Average Tensile yield Elongation %-Transverse Direction, IS 13360 (Part 5/Sec 1) and
IS 13360 (Part 5/Sec 3)") |
- |
0 |
|
- |
9/Table-4(Average Tensile Break Elongation %-Machine Direction, IS 13360 (Part 5/Sec 1) and IS 13360 (Part 5/Sec 3)) |
- |
0 |
|
- |
9/Table-4(Average Tensile Break Elongation -Transverse Direction, IS 13360 (Part 5/Sec 1) and S 13360 (Part 5/Sec 3)) |
- |
1300 |
|
- |
9/Table-4(Average Tear resistance, IS 2508: 2024 Annex-D) |
- |
1600 |
|
- |
|
31 Dec, 2026 |
- Included w.e.f 16.06.2025 |
800 |
SHRI KRISHNA TEST HOUSE PVT LTD (142)
| 8185606
| IS 302 : Part 2 : SEC 31 (2009) |
Safety of household and similar electrical appliances: Part 2 particular requirements: Sec 31 range hoods |
All |
34000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
Clause No - 5(GENERAL CONDITIONS FOR THE TESTS) |
- |
34000 |
|
- |
Clause No - 5.18(linear and angular dimension) |
- |
34000 |
|
- |
Clause No - 6.2(harmfull ingress of water) |
- |
34000 |
|
- |
Clause No - 8.1.1("PROTECTION AGAINST ACCESS TO LIVE
PART- test probe B") |
- |
34000 |
|
- |
Clause No - 8.1.2("PROTECTION AGAINST ACCESS TO LIVE
PART - test probe 13") |
- |
34000 |
|
- |
Clause No - 8.2(Addition) |
- |
34000 |
|
- |
Clause No - 10.1, Table No. -1(power input deviation) |
- |
34000 |
|
- |
Clause No - 13.3("LEAKAGE CURRENT AND ELECTRIC
STRENGTH AT OPERATING TEMPERATURE") |
- |
34000 |
|
- |
Clause No - 13.3,Table No.- 4(voltage for electrical strength) |
- |
34000 |
|
- |
Clause No - 14(Impulse test voltage) |
- |
34000 |
|
- |
Clause No - 15.1.1(MOISTURE RESISTANCE) |
- |
34000 |
|
- |
Clause No -19.7(test is repeated with the capacitor short circuited) |
- |
34000 |
|
- |
Clause No -19.11.4.1(electrostatic discharge) |
- |
34000 |
|
- |
Clause No -19.11.4.2(radiated field) |
- |
34000 |
|
- |
Clause No -19.11.4.3(fast transient) |
- |
34000 |
|
- |
Clause No -19.11.4.4(Voltage dips and interruption) |
- |
34000 |
|
- |
Clause No -21.1(Mechanical strength) |
- |
34000 |
|
- |
Clause No -22.1(construction) |
- |
34000 |
|
- |
Clause No -22.11(push force applied) |
- |
34000 |
|
- |
Clause No -24.1.2(safety isolating transformer) |
- |
34000 |
|
- |
Clause No -24.1.3(for switches) |
- |
34000 |
|
- |
Clause No -24.1.4(for automatic control) |
- |
34000 |
|
- |
Clause No -24.1.5(for innterconnection couplers) |
- |
34000 |
|
- |
Clause No -24.4(plug and socket) |
- |
34000 |
|
- |
Clause No -25.8, Table no -11(conductor resistance) |
- |
34000 |
|
- |
Clause No -25.5(dimension for pins) |
- |
34000 |
|
- |
Clause No -27.6(for circuit board) |
- |
34000 |
|
- |
Clause No -29.2(comparative tracking index) |
- |
34000 |
|
- |
Clause No -29.3.3(dry heat test) |
- |
34000 |
|
- |
Clause No -30.2.1(glow wire test) |
- |
34000 |
|
- |
Clause No -30.101("incorporate combustible
material") |
- |
34000 |
|
- |
15(MOISTURE RESISTANCE) |
- |
34000 |
|
- |
16(LEAKAGE CURRENT AND ELECTRIC STRENGTH) |
- |
34000 |
|
- |
17(OVERLOAD PROTECTION OF TRANSFORMERS AND ASSOCIATED CIRCUITS) |
- |
34000 |
|
- |
18(ENDURANCE) |
- |
34000 |
|
- |
28(SCREWS AND CONNECTIONS) |
- |
34000 |
|
- |
31(RESISTANCE TO RUSTING) |
- |
34000 |
|
- |
19.11.4.5(Immunity to conducted discharges) |
- |
34000 |
|
- |
19.11.4.6(Class 3 Voltage dips and interruptions) |
- |
34000 |
|
- |
19.11.4.7(Harmonics) |
- |
34000 |
|
- |
22(CONSTRUCTION) |
- |
34000 |
|
- |
24(COMPONENTS) |
- |
34000 |
|
- |
32(RADIATION, TOXICITY AND SIMILAR
HAZARDS) |
- |
34000 |
|
- |
11(Heating) |
- |
34000 |
|
- |
Clause No - 5(GENERAL CONDITIONS FOR THE TESTS) |
- |
34000 |
|
- |
Clause No - 5.18(linear and angular dimension) |
- |
34000 |
|
- |
Clause No - 6.2(harmfull ingress of water) |
- |
34000 |
|
- |
Clause No - 8.1.1("PROTECTION AGAINST ACCESS TO LIVE
PART- test probe B") |
- |
34000 |
|
- |
Clause No - 8.1.2("PROTECTION AGAINST ACCESS TO LIVE
PART - test probe 13") |
- |
34000 |
|
- |
Clause No - 8.2(Addition) |
- |
34000 |
|
- |
Clause No - 10.1, Table No. -1(power input deviation) |
- |
34000 |
|
- |
Clause No - 13.3("LEAKAGE CURRENT AND ELECTRIC
STRENGTH AT OPERATING TEMPERATURE") |
- |
34000 |
|
- |
Clause No - 13.3,Table No.- 4(voltage for electrical strength) |
- |
34000 |
|
- |
Clause No - 14(Impulse test voltage) |
- |
34000 |
|
- |
Clause No - 15.1.1(MOISTURE RESISTANCE) |
- |
34000 |
|
- |
Clause No -19.7(test is repeated with the capacitor short circuited) |
- |
34000 |
|
- |
Clause No -19.11.4.1(electrostatic discharge) |
- |
34000 |
|
- |
Clause No -19.11.4.2(radiated field) |
- |
34000 |
|
- |
Clause No -19.11.4.3(fast transient) |
- |
34000 |
|
- |
Clause No -19.11.4.4(Voltage dips and interruption) |
- |
34000 |
|
- |
Clause No -21.1(Mechanical strength) |
- |
34000 |
|
- |
Clause No -22.1(construction) |
- |
34000 |
|
- |
Clause No -22.11(push force applied) |
- |
34000 |
|
- |
Clause No -24.1.2(safety isolating transformer) |
- |
34000 |
|
- |
Clause No -24.1.3(for switches) |
- |
34000 |
|
- |
Clause No -24.1.4(for automatic control) |
- |
34000 |
|
- |
Clause No -24.1.5(for innterconnection couplers) |
- |
34000 |
|
- |
Clause No -24.4(plug and socket) |
- |
34000 |
|
- |
Clause No -25.8, Table no -11(conductor resistance) |
- |
34000 |
|
- |
Clause No -25.5(dimension for pins) |
- |
34000 |
|
- |
Clause No -27.6(for circuit board) |
- |
34000 |
|
- |
Clause No -29.2(comparative tracking index) |
- |
34000 |
|
- |
Clause No -29.3.3(dry heat test) |
- |
34000 |
|
- |
Clause No -30.2.1(glow wire test) |
- |
34000 |
|
- |
Clause No -30.101("incorporate combustible
material") |
- |
34000 |
|
- |
15(MOISTURE RESISTANCE) |
- |
34000 |
|
- |
16(LEAKAGE CURRENT AND ELECTRIC STRENGTH) |
- |
34000 |
|
- |
17(OVERLOAD PROTECTION OF TRANSFORMERS AND ASSOCIATED CIRCUITS) |
- |
34000 |
|
- |
18(ENDURANCE) |
- |
34000 |
|
- |
28(SCREWS AND CONNECTIONS) |
- |
34000 |
|
- |
31(RESISTANCE TO RUSTING) |
- |
34000 |
|
- |
19.11.4.5(Immunity to conducted discharges) |
- |
34000 |
|
- |
19.11.4.6(Class 3 Voltage dips and interruptions) |
- |
34000 |
|
- |
19.11.4.7(Harmonics) |
- |
34000 |
|
- |
22(CONSTRUCTION) |
- |
34000 |
|
- |
24(COMPONENTS) |
- |
34000 |
|
- |
32(RADIATION, TOXICITY AND SIMILAR
HAZARDS) |
- |
34000 |
|
- |
11(Heating) |
- |
34000 |
|
- |
Clause No - 5(GENERAL CONDITIONS FOR THE TESTS) |
- |
34000 |
|
- |
Clause No - 5.18(linear and angular dimension) |
- |
34000 |
|
- |
Clause No - 6.2(harmfull ingress of water) |
- |
34000 |
|
- |
Clause No - 8.1.1("PROTECTION AGAINST ACCESS TO LIVE
PART- test probe B") |
- |
34000 |
|
- |
Clause No - 8.1.2("PROTECTION AGAINST ACCESS TO LIVE
PART - test probe 13") |
- |
34000 |
|
- |
Clause No - 8.2(Addition) |
- |
34000 |
|
- |
Clause No - 10.1, Table No. -1(power input deviation) |
- |
34000 |
|
- |
Clause No - 13.3("LEAKAGE CURRENT AND ELECTRIC
STRENGTH AT OPERATING TEMPERATURE") |
- |
34000 |
|
- |
Clause No - 13.3,Table No.- 4(voltage for electrical strength) |
- |
34000 |
|
- |
Clause No - 14(Impulse test voltage) |
- |
34000 |
|
- |
Clause No - 15.1.1(MOISTURE RESISTANCE) |
- |
34000 |
|
- |
Clause No -19.7(test is repeated with the capacitor short circuited) |
- |
34000 |
|
- |
Clause No -19.11.4.1(electrostatic discharge) |
- |
34000 |
|
- |
Clause No -19.11.4.2(radiated field) |
- |
34000 |
|
- |
Clause No -19.11.4.3(fast transient) |
- |
34000 |
|
- |
Clause No -19.11.4.4(Voltage dips and interruption) |
- |
34000 |
|
- |
Clause No -21.1(Mechanical strength) |
- |
34000 |
|
- |
Clause No -22.1(construction) |
- |
34000 |
|
- |
Clause No -22.11(push force applied) |
- |
34000 |
|
- |
Clause No -24.1.2(safety isolating transformer) |
- |
34000 |
|
- |
Clause No -24.1.3(for switches) |
- |
34000 |
|
- |
Clause No -24.1.4(for automatic control) |
- |
34000 |
|
- |
Clause No -24.1.5(for innterconnection couplers) |
- |
34000 |
|
- |
Clause No -24.4(plug and socket) |
- |
34000 |
|
- |
Clause No -25.8, Table no -11(conductor resistance) |
- |
34000 |
|
- |
Clause No -25.5(dimension for pins) |
- |
34000 |
|
- |
Clause No -27.6(for circuit board) |
- |
34000 |
|
- |
Clause No -29.2(comparative tracking index) |
- |
34000 |
|
- |
Clause No -29.3.3(dry heat test) |
- |
34000 |
|
- |
Clause No -30.2.1(glow wire test) |
- |
34000 |
|
- |
Clause No -30.101("incorporate combustible
material") |
- |
34000 |
|
- |
15(MOISTURE RESISTANCE) |
- |
34000 |
|
- |
16(LEAKAGE CURRENT AND ELECTRIC STRENGTH) |
- |
34000 |
|
- |
17(OVERLOAD PROTECTION OF TRANSFORMERS AND ASSOCIATED CIRCUITS) |
- |
34000 |
|
- |
18(ENDURANCE) |
- |
34000 |
|
- |
28(SCREWS AND CONNECTIONS) |
- |
34000 |
|
- |
31(RESISTANCE TO RUSTING) |
- |
34000 |
|
- |
19.11.4.5(Immunity to conducted discharges) |
- |
34000 |
|
- |
19.11.4.6(Class 3 Voltage dips and interruptions) |
- |
34000 |
|
- |
19.11.4.7(Harmonics) |
- |
34000 |
|
- |
22(CONSTRUCTION) |
- |
34000 |
|
- |
24(COMPONENTS) |
- |
34000 |
|
- |
32(RADIATION, TOXICITY AND SIMILAR
HAZARDS) |
- |
34000 |
|
- |
11(Heating) |
- |
34000 |
|
- |
|
13 May, 2028 |
- Included w.e.f 02.07.2025 Exclusion: Cl 19.11.4.1-19.11.4.7(EMI/EMC) |
801 |
ATCC TEST LABS LLP
| 8172626
| IS 2993 : Part 1 (2024) |
a.c. Motor Capacitors Part 1 General - Performance, Testing and Rating - Safety Requirements - Guidance for Installation and Operation ( Third Revision ) |
- |
450000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
5.1.1(General) |
- |
5000 |
|
- |
5.5(Tangent of loss angle) |
- |
10000 |
|
- |
5.7("Voltage test between terminals
") |
- |
5000 |
|
- |
5.8(Voltage test between terminals and case) |
- |
5000 |
|
- |
5.9(Capacitance measurement) |
- |
5000 |
|
- |
5.9(Capacitance measurement) |
- |
5000 |
|
- |
5.1(Check of dimensions) |
- |
5000 |
|
- |
5.11(Mechanical tests) |
- |
20000 |
|
- |
5.12(Sealing test) |
- |
10000 |
|
- |
5.13(Endurance test) |
- |
110000 |
|
- |
5.14(Damp heat test) |
- |
60000 |
|
- |
5.15(Self-healing test) |
- |
10000 |
|
- |
5.16(Destruction test) |
- |
40000 |
|
- |
5.17(Resistance to heat, fire and tracking) |
- |
20000 |
|
- |
5.17.1(Ball-pressure test) |
- |
5000 |
|
- |
5.17.2(Glow-wire test) |
- |
5000 |
|
- |
5.17.3(Tracking test) |
- |
5000 |
|
- |
6.1(Maximum permissible voltage) |
- |
5000 |
|
- |
6.2("Maximum permissible current
") |
- |
5000 |
|
- |
6.3(Maximum permissible reactive output) |
- |
10000 |
|
- |
7(Safety requirements) |
- |
10000 |
|
- |
7.1(Requirements for Creepage distances and clearances) |
- |
5000 |
|
- |
7.2(Terminals and connecting cables) |
- |
5000 |
|
- |
7.3(Earth connections) |
- |
5000 |
|
- |
7.4(Discharge devices) |
- |
40000 |
|
- |
8(Marking) |
- |
5000 |
|
- |
9.2.1(Measurements of working voltage) |
- |
5000 |
|
- |
9.2.2(Influence of capacitance) |
- |
5000 |
|
- |
9.3(Checking capacitor temperature) |
- |
5000 |
|
- |
9.4(Checking transients) |
- |
10000 |
|
- |
9.5(Leakage current) |
- |
10000 |
|
- |
5.1.1(General) |
- |
5000 |
|
- |
5.5(Tangent of loss angle) |
- |
10000 |
|
- |
5.7("Voltage test between terminals
") |
- |
5000 |
|
- |
5.8(Voltage test between terminals and case) |
- |
5000 |
|
- |
5.9(Capacitance measurement) |
- |
5000 |
|
- |
5.9(Capacitance measurement) |
- |
5000 |
|
- |
5.1(Check of dimensions) |
- |
5000 |
|
- |
5.11(Mechanical tests) |
- |
20000 |
|
- |
5.12(Sealing test) |
- |
10000 |
|
- |
5.13(Endurance test) |
- |
110000 |
|
- |
5.14(Damp heat test) |
- |
60000 |
|
- |
5.15(Self-healing test) |
- |
10000 |
|
- |
5.16(Destruction test) |
- |
40000 |
|
- |
5.17(Resistance to heat, fire and tracking) |
- |
20000 |
|
- |
5.17.1(Ball-pressure test) |
- |
5000 |
|
- |
5.17.2(Glow-wire test) |
- |
5000 |
|
- |
5.17.3(Tracking test) |
- |
5000 |
|
- |
6.1(Maximum permissible voltage) |
- |
5000 |
|
- |
6.2("Maximum permissible current
") |
- |
5000 |
|
- |
6.3(Maximum permissible reactive output) |
- |
10000 |
|
- |
7(Safety requirements) |
- |
10000 |
|
- |
7.1(Requirements for Creepage distances and clearances) |
- |
5000 |
|
- |
7.2(Terminals and connecting cables) |
- |
5000 |
|
- |
7.3(Earth connections) |
- |
5000 |
|
- |
7.4(Discharge devices) |
- |
40000 |
|
- |
8(Marking) |
- |
5000 |
|
- |
9.2.1(Measurements of working voltage) |
- |
5000 |
|
- |
9.2.2(Influence of capacitance) |
- |
5000 |
|
- |
9.3(Checking capacitor temperature) |
- |
5000 |
|
- |
9.4(Checking transients) |
- |
10000 |
|
- |
9.5(Leakage current) |
- |
10000 |
|
- |
|
15 Jun, 2026 |
- - |
802 |
EMC Testing and Compliance LLP, Gurugram
| 8141526
| IS 9873 : Part 1 (2019) |
Safety of toys: Part 1 safety aspects related to mechanical and physical properties (Fourth Revision) |
Electric & Non-Electric Toys |
4500 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
4.2 - 5.24.2( Reasonably foreseeable abuse -Drop Test) |
- |
200 |
|
- |
4.2 - 5.24.3( Reasonably foreseeable abuse -Tip-over test for large and bulky toys) |
- |
200 |
|
- |
4.2 - 5.24.4( Reasonably foreseeable abuse -Dynamic strength test for wheeled ride-on toys other than toy scooters) |
- |
200 |
|
- |
4.2 - 5.24.5( Reasonably foreseeable abuse -Torque test) |
- |
200 |
|
- |
4.2 - 5.24.6.2( Reasonably foreseeable abuse -Tension test for seams in soft-filled (stuffed) toys. beanbag-type toys, and other similar filled toys) |
- |
200 |
|
- |
4.2 - 5.24.6.3( Reasonably foreseeable abuse -Tension test for pompoms) |
- |
200 |
|
- |
4.2 - 5.24.6.4( Reasonably foreseeable abuse -Tension test for protective components) |
- |
200 |
|
- |
4.2 - 5.24.6.5( Reasonably foreseeable abuse -Tension test for a projectile with a suction cup) |
- |
200 |
|
- |
4.2 - 5.24.7( Reasonably foreseeable abuse -Compression test) |
- |
200 |
|
- |
4.2 - 5.24.8.2( Reasonably foreseeable abuse-Flexure test-Wires and other metallic components intended to be bent) |
- |
200 |
|
- |
4.2 - 5.24.8.3( Reasonably foreseeable abuse -Flexure test-Wires likely to be bent) |
- |
200 |
|
- |
4.3.2 - 5.21( Expanding materials) |
- |
2000 |
|
- |
4.4.1 - 5.2(Small parts-For children under 36 months) |
- |
200 |
|
- |
4.4.2 - 5.2(Small parts-For children 36 months and over but under 72 months
) |
- |
200 |
|
- |
4.5.1.2 - 5.3(Shape, size and strength of certain toys-Squeeze toys, rattles, and certain other toys and components of toys-Test for shape and size of certain toys) |
- |
200 |
|
- |
4.5.1.3 - 5.3(Shape, size and strength of certain toys-Other toys or components of toys with nearly spherical, hemispherical, circular
flared, or dome-shaped ends of toys having a mass less than 0,5 kg and intended for children
under 18 months-Test for shape and size of certain toys) |
- |
200 |
|
- |
4.5.1.4 - 5.3(Shape, size and strength of certain toys-Toy fasteners (e.g. nails, bolts, screws, and pegs) with nearly spherical, hemispherical,
or dome-shaped ends intended for children 18 months and over but under 48 months-Test for shape and size of certain toys) |
- |
200 |
|
- |
4.5.2 - 5.4(Shape, size and strength of certain toys-Small balls-Small balls test) |
- |
200 |
|
- |
4.5.3 - 5.5(Shape, size and strength of certain toys-Pompoms-Test for pompoms) |
- |
200 |
|
- |
4.5.4 - 5.6(Shape, size and strength of certain toys- Pre-school play figures-Test for pre-school play figures) |
- |
200 |
|
- |
4.5.5(Shape, size and strength of certain toys-Toy pacifiers-Nipple length) |
- |
200 |
|
- |
4.5.6(Shape, size and strength of certain toys-Balloons) |
- |
200 |
|
- |
4.5.7(Shape, size and strength of certain toys-Marbles) |
- |
200 |
|
- |
4.5.8 - a(Shape, size and strength of certain toys-Hemispheric-shaped toys-No of Opening) |
- |
200 |
|
- |
4.5.8 - a(Shape, size and strength of certain toys-Hemispheric-shaped toys-Position of opening in Base) |
- |
200 |
|
- |
4.5.8 - b(Shape, size and strength of certain toys-Hemispheric-shaped toys-Extension of divider) |
- |
200 |
|
- |
4.5.8 - c(Shape, size and strength of certain toys-Hemispheric-shaped toys-No of Opening) |
- |
200 |
|
- |
4.5.8 - c(Shape, size and strength of certain toys-Hemispheric-shaped toys-Position of opening ) |
- |
200 |
|
- |
4.5.8 - d(Shape, size and strength of certain toys-Hemispheric-shaped toys) |
- |
200 |
|
- |
4.5.8 - d(Shape, size and strength of certain toys-Hemispheric-shaped toys-The maximum distance between centrelines of adjacent peaks ) |
- |
200 |
|
- |
4.5.8 - d(Shape, size and strength of certain toys-Hemispheric-shaped toys-Minimum depth) |
- |
200 |
|
- |
4.6.1 a - 5.8(Edges-Accessible sharp edges of glass or metal-Sharp edge test) |
- |
200 |
|
- |
4.6.1 b(Edges-Accessible sharp edges of glass or metal- gap between the edge and the adjacent surface) |
- |
200 |
|
- |
4.6.2(Edges-Functional sharp edges) |
- |
200 |
|
- |
4.6.3 - 5.8(Edges-Edges on metal toys-Sharp edge test) |
- |
200 |
|
- |
4.6.4( Edges-Edges on moulded toys) |
- |
200 |
|
- |
4.6.5( Edges-Edges on exposed bolts or threaded rod) |
- |
200 |
|
- |
4.7.1 - 5.9(Points-Accessible sharp points-sharp-point test) |
- |
200 |
|
- |
4.7.2 - a(Points-Functional sharp points) |
- |
200 |
|
- |
4.7.2 - b(Points-Functional sharp points) |
- |
200 |
|
- |
4.7.3 (Wooden toys) |
- |
200 |
|
- |
4.8.1(Projections-General requirments) |
- |
200 |
|
- |
4.9(a) - 5.24.8.2( Metal wires and rods-wires and other metallic components intended to be bent) |
- |
200 |
|
- |
4.9(b) - 5.24.8.3( Metal wires and rods-wires likely to be bent) |
- |
200 |
|
- |
4.9 - c( Metal wires and rods) |
- |
200 |
|
- |
4.9 - c - 5.8( Metal wires and rods-Sharp edge test) |
- |
200 |
|
- |
4.9 - c - 5.9( Metal wires and rods-Sharp Point test) |
- |
200 |
|
- |
4.9 - c( Metal wires and rods-Minimum dia of spokes) |
- |
200 |
|
- |
4.10(a) - 5.10(Plastic film or plastic bags in packaging and in toys-average thickness) |
- |
200 |
|
- |
4.10(a) - 5.10(Plastic film or plastic bags in packaging and in toys- individual thickness) |
- |
200 |
|
- |
4.11.2.1(a) - 5.11.2( Cords-Cords in toys intended for children under 18 months-Cords with the potential to tangle-Length of cords and electrical cables) |
- |
200 |
|
- |
4.11.2.1(b) - 5.11.3( Cords-Cords in toys intended for children under 18 months-Cords with the potential to tangle-breakaway feature separation test) |
- |
200 |
|
- |
4.11.2.1(b) - 5.11.2( Cords-Cords in toys intended for children under 18 months-Cords with the potential to tangle-Length of cords and electrical cables after breakaway feature separation test) |
- |
200 |
|
- |
4.11.2.2 - 5.11.2( Cords-Cords in toys intended for children under 18 months--Other cords-free length ) |
- |
200 |
|
- |
4.11.3.3 ( Cords-Cords in toys intended for children 18 months and over but under 36 months-Other cords without a free end
) |
- |
200 |
|
- |
4.11.3.2( Cords-Cords in toys intended for children 18 months and over but under 36 months-Other cords) |
- |
200 |
|
- |
4.11.4(a) - 5.11.4.1(Cords-Fixed loops and nooses intended for children under 36 months-Test for fixed loops and nooses-Head probe push test) |
- |
200 |
|
- |
4.11.4(a) - 5.11.4.2(Cords-Fixed loops and nooses intended for children under 36 months-Test for fixed loops and nooses-Elastic materials) |
- |
200 |
|
- |
4.11.4(b) - 5.11.3(Cords-Fixed loops and nooses intended for children under 36 months-Breakaway feature separation test) |
- |
200 |
|
- |
4.11.5 - 5.11.2(Cords-Cords on pull toys-free length) |
- |
200 |
|
- |
4.11.6(Cords- Electrical cables) |
- |
500 |
|
- |
4.11.7 - 5.11.1(Cords- Diameter of certain cords intended for children under 36 months-cords cross-sectional
dimension) |
- |
200 |
|
- |
4.11.8 - 5.11.5(Cords- Self-retracting cords intended for children under 36 months-self-retracting cords) |
- |
200 |
|
- |
4.11.9.1(Cords-Toys intended to be strung across a cradle, cot, perambulator or carriage) |
- |
200 |
|
- |
4.11.9.2 (Cords-Toys otherwise intended to be attached to a cradle, cot, perambulator or carriage) |
- |
200 |
|
- |
4.11.10(Cords-Cords on toy bags) |
- |
200 |
|
- |
4.11.11 - 5.11.6( Cords, strings and lines for flying toys- electrical resistance) |
- |
200 |
|
- |
4.11.11( Cords, strings and lines for flying toys- ) |
- |
200 |
|
- |
4.12.1(a - 1)(Folding mechanisms-Toy pushchairs, perambulators and similar toys) |
- |
200 |
|
- |
4.12.1(a - 2)(Folding mechanisms-Toy pushchairs, perambulators and similar toys) |
- |
200 |
|
- |
4.12.1(a - 3) - 5.22.2(Folding mechanisms-Toy pushchairs, perambulators and similar toys-toy pushchairs and perambulators) |
- |
200 |
|
- |
4.12.2 (a) - 5.22.3(Folding mechanisms-Other toys with folding mechanisms) |
- |
500 |
|
- |
4.12.1(a - 4)(Folding mechanisms-Toy pushchairs, perambulators and similar toys) |
- |
500 |
|
- |
4.12.3(Folding mechanisms-Hinge line clearance) |
- |
500 |
|
- |
4.13.1(Holes, clearances and accessibility of mechanisms-Circular holes in rigid materials) |
- |
500 |
|
- |
4.13.2 (Holes, clearances and accessibility of mechanisms-Accessible clearances for movable segments) |
- |
500 |
|
- |
4.13.3(Holes, clearances and accessibility of mechanisms- Chains or belts in ride-on toys) |
- |
500 |
|
- |
4.13.3 - 5.7(Holes, clearances and accessibility of mechanisms- Chains or belts in ride-on toys-accessibility of a part or component) |
- |
500 |
|
- |
4.13.3(Holes, clearances and accessibility of mechanisms- Chains or belts in ride-on toys) |
- |
500 |
|
- |
4.13.4(Holes, clearances and accessibility of mechanisms-Other driving mechanisms) |
- |
500 |
|
- |
4.13.5(Holes, clearances and accessibility of mechanisms-Winding keys) |
- |
500 |
|
- |
4.14(a)(Springs) |
- |
500 |
|
- |
4.14(b)(Springs) |
- |
500 |
|
- |
4.14(c)(Springs) |
- |
500 |
|
- |
4.15.1.1 - 5.12.2( Stability and overload requirements-Stability of ride-on toys and seats-Sideways stability, feet available for stabilization) |
- |
500 |
|
- |
4.15.1.2 - 5.12.3( Stability and overload requirements-Stability of ride-on toys and seats-Sideways stability, feet unavailable for stabilization) |
- |
500 |
|
- |
4.15.1.3 - 5.12.4( Stability and overload requirements-Stability of ride-on toys and seats-Fore and aft stability Test) |
- |
500 |
|
- |
4.15.2 - 5.12.5( Stability and overload requirements-Overload requirements for ride-on toys and seats-overload test for ride-on toys and seats) |
- |
500 |
|
- |
4.15.2 - 5.24.4( Stability and overload requirements-Overload requirements for ride-on toys and seats-dynamic strength test for wheeled ride-on toys other than toy scooters) |
- |
500 |
|
- |
4.15.3 - 5.12.6( Stability and overload requirements-Stability of stationary floor toy-Stability test of stationary floor toys) |
- |
500 |
|
- |
4.16.1(Enclosures-Ventilation) |
- |
500 |
|
- |
4.16.2.1 - 5.13.1(Enclosures-Closures-Lids, doors and similar devices-Test For closures) |
- |
500 |
|
- |
4.16.2.2(a)(Enclosures-Closures-Lid support for toy chests and similar toys) |
- |
500 |
|
- |
4.16.1(Enclosures-Ventilation-No of openings) |
- |
500 |
|
- |
4.16.1(Enclosures-Ventilation-Area of Each openings(If two openings)) |
- |
500 |
|
- |
4.16.1(Enclosures-Ventilation-Distance between openings(If two openings)) |
- |
500 |
|
- |
4.16.1(Enclosures-Ventilation-Area of Each openings(If One opening)) |
- |
500 |
|
- |
4.16.2.2(a) - 5.13.2.1(Enclosures-Closures-Lid support for toy chests and similar toys-Test For lid support) |
- |
500 |
|
- |
4.16.2.2(a) - 5.13.2.2(Enclosures-Closures-Lid support for toy chests and similar toys- After durability test for toy chest lids) |
- |
500 |
|
- |
4.16.2.2(a) - 5.13.2.2(Enclosures-Closures-Lid support for toy chests and similar toys-Test For lid support After durability test for toy chest lids) |
- |
500 |
|
- |
4.16.2.2(b) - 5.13.2.2(Enclosures-Closures-Lid support for toy chests and similar toys-durability test for toy chest lids) |
- |
500 |
|
- |
4.16.2.2(c) - 5.13.2.2 - 4.12.1(a - 1)(Enclosures-Closures-Lid support for toy chests and similar toys-Folding mechanisms-Toy pushchairs, perambulators and similar toys) |
- |
500 |
|
- |
4.16.2.2(c) - 5.13.2.2 - 4.12.1(a - 2)(Enclosures-Closures-Lid support for toy chests and similar toys-Folding mechanisms-Toy pushchairs, perambulators and similar toys) |
- |
500 |
|
- |
4.16.2.2(c) - 5.13.2.2 - 4.12.1(a - 3) - 5.22.2(Enclosures-Closures-Lid support for toy chests and similar toys-Folding mechanisms-Toy pushchairs, perambulators and similar toys-toy pushchairs and perambulators) |
- |
500 |
|
- |
4.16.2.2(c) - 5.13.2.2 - 4.12.1(a - 4)(Enclosures-Closures-Lid support for toy chests and similar toys-Folding mechanisms-Toy pushchairs, perambulators and similar toys) |
- |
500 |
|
- |
4.16.2.2(c) - 5.13.2.2 - 4.12.1(a - 5) - 5.22.2(Enclosures-Closures-Lid support for toy chests and similar toys-Folding mechanisms-Toy pushchairs, perambulators and similar toys) |
- |
500 |
|
- |
4.16.2.2(c) - 5.13.2.2 - 4.12.1(b - 1)(Enclosures-Closures-Lid support for toy chests and similar toys-Folding mechanisms-Toy pushchairs, perambulators and similar toys) |
- |
500 |
|
- |
4.16.2.2(c) - 5.13.2.2 - 4.12.1(b - 2) - 5.22.2(Enclosures-Closures-Lid support for toy chests and similar toys-Folding mechanisms-Toy pushchairs, perambulators and similar toys) |
- |
500 |
|
- |
4.16.2.2(c) - 5.13.2.2 - 4.12.1(b - 3) - 5.22.2(Enclosures-Closures-Lid support for toy chests and similar toys-Folding mechanisms-Toy pushchairs, perambulators and similar toys) |
- |
500 |
|
- |
4.16.2.2(c) - 5.13.2.2 - 4.12.2 (a) - 5.22.3(Enclosures-Closures-Lid support for toy chests and similar toys-Folding mechanisms-Other toys with folding mechanisms) |
- |
500 |
|
- |
4.16.2.2(c) - 5.13.2.2 - 4.12.2 (b)(Enclosures-Closures-Lid support for toy chests and similar toys-Folding mechanisms-Other toys with folding mechanisms) |
- |
500 |
|
- |
4.16.2.2(c) - 5.13.2.2 - 4.12.3(Enclosures-Closures-Lid support for toy chests and similar toys-Folding mechanisms-Hinge line clearance) |
- |
500 |
|
- |
4.16.2.2(d)(Enclosures-Closures-Lid support for toy chests and similar toys) |
- |
500 |
|
- |
4.16.3(Enclosures-Toys that enclose the head) |
- |
500 |
|
- |
4.16.3(Enclosures-Toys that enclose the head-No of openings) |
- |
500 |
|
- |
4.16.3(Enclosures-Toys that enclose the head-Area of Each openings(If two openings)) |
- |
500 |
|
- |
4.16.3(Enclosures-Toys that enclose the head-Distance between openings(If two openings)) |
- |
500 |
|
- |
4.17 - 5.14(Simulated protective equipment, such as helmets, hats and goggles-Impact test for toys that cover the face) |
- |
500 |
|
- |
4.17(Simulated protective equipment, such as helmets, hats and goggles) |
- |
500 |
|
- |
4.18.2(a) - 5.36(Projectile toys-Projectiles-tip assessment of rigid projectiles) |
- |
500 |
|
- |
4.18.2(b)(Projectile toys-Projectiles) |
- |
500 |
|
- |
4.18.2(c)(Projectile toys-Projectiles) |
- |
500 |
|
- |
4.18.2(c)(Projectile toys-Projectiles-Radius) |
- |
500 |
|
- |
4.18.2(d) - 5.37(Projectile toys-Projectiles-length of suction cup projectiles) |
- |
500 |
|
- |
4.18.2(d) - 5.37 - 5.24.5(Projectile toys-Projectiles-length of suction cup projectiles After torque test) |
- |
500 |
|
- |
4.18.2(d) - 5.37 - 5.24.6.5(Projectile toys-Projectiles-length of suction cup projectiles After tension test for a projectile with a suction cup) |
- |
500 |
|
- |
4.18.2 - e - 5.24.5(Projectile toys-Projectiles-torque test) |
- |
500 |
|
- |
4.18.2 - e - 5.24.6.5(Projectile toys-Projectiles-tension test for a projectile with a suction cup) |
- |
500 |
|
- |
4.18.3(a) - 5.2(Projectile toys-Projectile toys with stored energy-small parts test) |
- |
500 |
|
- |
4.18.3(a) - 5.3 - 5.24(Projectile toys-Projectile toys with stored energy-small parts test after reasonably foreseeable abuse testing) |
- |
500 |
|
- |
4.18.3(a) - 5.4(Projectile toys-Projectile toys with stored energy--small parts test after (wall impact test for projectiles) |
- |
500 |
|
- |
4.18.3(b) - 5.15.1.3.3(Projectile toys-Projectile toys with stored energy-determination of kinetic energy per area of contact) |
- |
500 |
|
- |
4.18.3(c ) - 5.24.5(Projectile toys-Projectile toys with stored energy-torque test) |
- |
500 |
|
- |
4.18.3(c ) - 5.24.6.4(Projectile toys-Projectile toys with stored energy- tension test for protective components) |
- |
500 |
|
- |
4.18.3(c )(Projectile toys-Projectile toys with stored energy) |
- |
500 |
|
- |
4.18.3(d) - 5.15.2(Projectile toys-Projectile toys with stored energy-Wall impact test for projectiles) |
- |
500 |
|
- |
4.18.3(e )(Projectile toys-Projectile toys with stored energystored energy-Discharge mechanism) |
- |
500 |
|
- |
4.18.4.1 - 5.20(Projectile toys-Projectile toys without stored energy-Mouth-actuated projectile toys-durability of mouth-actuated toys) |
- |
500 |
|
- |
4.18.4.2(a) - 5.15.1.3.3(Projectile toys-Projectile toys without stored energy-Projectiles in the form of a dart-determination of the kinetic energy per area of contact when the contact area of the dart shall be at least 3 cm^2) |
- |
500 |
|
- |
4.18.4.2(b)(Projectile toys-Projectile toys without stored energy-Projectiles in the form of a dart) |
- |
500 |
|
- |
4.18.4.2(c ) - 5.24.5(Projectile toys-Projectile toys without stored energy-Projectiles in the form of a dart-After torque test) |
- |
500 |
|
- |
4.18.4.2(c ) - 5.24.5(Projectile toys-Projectile toys without stored energy-Projectiles in the form of a dart-Contact area After torque test) |
- |
500 |
|
- |
4.18.4.2(c ) - 5.24.6.4(Projectile toys-Projectile toys without stored energy-Projectiles in the form of a dart-After tension test for protective
components) |
- |
500 |
|
- |
4.18.4.3 - 5.15.1.3.3(Projectile toys-Projectile toys without stored energy-Arrows (e.g. bow and arrow set)-kinetic energy per area) |
- |
500 |
|
- |
4.18.4.6 - 5.24.6.4(Projectile toys-Projectile toys without stored energy-Arrows (e.g. bow and arrow set-After tension test for protective
components) |
- |
500 |
|
- |
4.18.4.6 - 5.24.6.4 - 5.15.1.3.3(Projectile toys-Projectile toys without stored energy-Arrows (e.g. bow and arrow set-kinetic energy per area After tension test for protective components) |
- |
500 |
|
- |
4.19(Rotors and propellers) |
- |
500 |
|
- |
4.2(Aquatic toys) |
- |
500 |
|
- |
4.21(a)(Braking) |
- |
500 |
|
- |
4.21(a)(Braking-brake performance for mechanically or electrically
powered ride-on toys other than toy bicycles) |
- |
500 |
|
- |
4.21(b)(braking) |
- |
500 |
|
- |
4.22.1(Toy bicycles-Instructions for use) |
- |
500 |
|
- |
4.22.2(Toy bicycles-Determination of maximum saddle height) |
- |
500 |
|
- |
4.22.3 - 5.16.1(Toy bicycles-Braking requirements-determination of free-wheeling
facility) |
- |
500 |
|
- |
4.22.3 (Toy bicycles-Braking requirements- brake lever dimension(d)) |
- |
500 |
|
- |
4.22.3 (Toy bicycles-Braking requirements- lever Length(l)) |
- |
500 |
|
- |
4.22.3 - 5.16.3(Toy bicycles-Braking requirements- brake performance for toy bicycles) |
- |
500 |
|
- |
4.23 - 5.17(Speed limitation of electrically driven ride-on toys-determination of speed of electrically driven ride-on toys) |
- |
5000 |
|
- |
4.24(a) - 5.18(Toys containing a heat source-determination of temperature increases) |
- |
2000 |
|
- |
4.24(b) - 5.18(Toys containing a heat source-rise in temperature of handles, knobs and similar parts which are likely to be touched by hand-(Parts made of metals)) |
- |
2000 |
|
- |
4.24(b) - 5.18(Toys containing a heat source-rise in temperature of handles, knobs and similar parts which are likely to be touched by hand(Parts made of glass or porcelain)) |
- |
2000 |
|
- |
4.24(b) - 5.18(Toys containing a heat source-rise in temperature of handles, knobs and similar parts which are likely to be touched by hand(Parts made of Plastic or wood )) |
- |
2000 |
|
- |
4.24(c) - 5.18(Toys containing a heat source- rise in temperature of other accessible parts of the toy(Parts made of metals)) |
- |
2000 |
|
- |
4.24(c) - 5.18(Toys containing a heat source- rise in temperature of other accessible parts of the toy( Parts made of other materials)) |
- |
2000 |
|
- |
4.25 - 5.19(Liquid-filled toys-leakage of liquid-filled toys) |
- |
500 |
|
- |
4.25(Liquid-filled toys) |
- |
500 |
|
- |
4.26(a) - 5.2( Mouth-actuated toys-small parts test) |
- |
500 |
|
- |
4.26(b) - 5.24.5 - 5.3( Mouth-actuated toys-small parts test after torque test) |
- |
500 |
|
- |
4.26(b) - 5.24.6.1 - 5.4( Mouth-actuated toys-small parts test after tension test, general procedure) |
- |
500 |
|
- |
4.26(c ) - 5.20 - 5.2( Mouth-actuated toys-small parts test after durability of mouth-actuated toys) |
- |
500 |
|
- |
4.27(Toy roller skates, toy inline skates and toy skateboards) |
- |
500 |
|
- |
4.28( Percussion caps specifically designed for use in toys) |
- |
500 |
|
- |
4.29(a) - 5.25(Acoustic requirements-determination of sound pressure levels) |
- |
5000 |
|
- |
4.29(b) - 5.25(Acoustic requirements-determination of sound pressure levels) |
- |
5000 |
|
- |
4.29(c) - 5.25(Acoustic requirements-determination of sound pressure levels) |
- |
5000 |
|
- |
4.29(d) - 5.25(Acoustic requirements-determination of sound pressure levels) |
- |
5000 |
|
- |
4.29(e) - 5.25(Acoustic requirements-determination of sound pressure levels) |
- |
5000 |
|
- |
4.29(f) - 5.25(Acoustic requirements-determination of sound pressure levels) |
- |
5000 |
|
- |
4.29(g) - 5.25(Acoustic requirements-determination of sound pressure levels) |
- |
5000 |
|
- |
4.30.2(Toy scooters-Warnings and instructions for use) |
- |
100 |
|
- |
4.30.3 - 5.26 - 5.8(Toy scooters-Strength-After static strength for toy scooters- sharp edge test) |
- |
200 |
|
- |
4.30.3 - 5.26 - 5.9(Toy scooters-Strength-static strength for toy scooters-sharp-point test) |
- |
200 |
|
- |
4.30.3 - 5.26(Toy scooters-Strength-static strength for toy scooters) |
- |
200 |
|
- |
4.30.3 - 5.27 - 5.8(Toy scooters-Strength-dynamic strength for toy scooters- sharp-edge test) |
- |
200 |
|
- |
4.30.3 - 5.27(Toy scooters-Strength-dynamic strength for toy scooters) |
- |
200 |
|
- |
4.30.3 - 5.29(Toy scooters-Strength-strength of toy scooter steering tubes) |
- |
5000 |
|
- |
4.30.4 - 5.12.2(Toy scooters-Stability-sideways stability test, feet available for stabilization) |
- |
200 |
|
- |
4.30.5(a)( Toy scooters-Adjustable and folding steering tubes and handlebars) |
- |
500 |
|
- |
4.30.5(b)( Toy scooters-Adjustable and folding steering tubes and handlebars) |
- |
500 |
|
- |
4.30.5(c)( Toy scooters-Adjustable and folding steering tubes and handlebars) |
- |
500 |
|
- |
4.30.5(d)( Toy scooters-Adjustable and folding steering tubes and handlebars) |
- |
500 |
|
- |
4.30.5(e)( Toy scooters-Adjustable and folding steering tubes and handlebars) |
- |
500 |
|
- |
4.30.5(f) - 5.30( Toy scooters-Adjustable and folding steering tubes and handlebars-resistance to separation of handlebar) |
- |
500 |
|
- |
4.30.6 ( Toy scooters-Braking) |
- |
500 |
|
- |
4.30.6 - 5.28( Toy scooters-Braking- force required to hold the toy) |
- |
500 |
|
- |
4.30.7( Toy scooters-Wheel size(diameter)) |
- |
500 |
|
- |
4.30.8(Toy scooters-Projections) |
- |
500 |
|
- |
4.30.8(Toy scooters-Projections(rounded handlebar grips or plugs Diameter)) |
- |
500 |
|
- |
4.30.8(Toy scooters-Projections(rounded handlebar grips or plugs space from end)) |
- |
500 |
|
- |
4.31(Magnets and magnetic components-Magnetic/electrical experimental sets intended for children 8 years and over) |
- |
500 |
|
- |
4.31.1 - 5.32(Magnets and magnetic components-Magnetic/electrical experimental sets intended for children 8 years and over-magnetic flux index) |
- |
500 |
|
- |
4.31.1 - 5.2(Magnets and magnetic components-Magnetic/electrical experimental sets intended for children 8 years and over-small parts test) |
- |
500 |
|
- |
4.31.2(a) - 5.32(Magnets and magnetic components-All other toys with magnets and magnetic components-magnetic flux index) |
- |
500 |
|
- |
4.31.2(b) - 5.34 - 5.2(Magnets and magnetic components-All other toys with magnets and magnetic components-soaking test for magnets-small parts test) |
- |
500 |
|
- |
4.31.2(c ) - 5.31 - 5.24.2 - 5.24.3 - 5.24.5 - 5.24.6.1 - 5.24.6.2 - 5.33 - 5.31 - 5.32(Magnets and magnetic components-All other toys with magnets and magnetic components-magnetic flux index After Following tests:
-tension test for magnets;
-drop test/tip over test for large and bulky toys;
-torque test;
-tension test, general procedure;
-tension test for seams in soft-filled (stuffed) toys, beanbag-type toys and other similar filled toys, if applicable;
-impact test for magnets;
-compression test;
-tension test for magnets;) |
- |
500 |
|
- |
4.31.2(c ) - 5.31 - 5.24.2 - 5.24.3 - 5.24.5 - 5.24.6.1 - 5.24.6.2 - 5.33 - 5.31 - 5.2(Magnets and magnetic components-All other toys with magnets and magnetic components-small parts test After Following tests:
-tension test for magnets;
-drop test/tip over test for large and bulky toys;
-torque test;
-tension test, general procedure;
-tension test for seams in soft-filled (stuffed) toys, beanbag-type toys and other similar filled toys, if applicable;
-impact test for magnets;
-compression test;
-tension test for magnets;) |
- |
500 |
|
- |
4.32 - 5.38.2( Yo-yo balls - length (lo) of the yo-yo ball tether) |
- |
500 |
|
- |
4.32 - 5.38.1( Yo-yo balls - The ratio of the mass m (in grams) to the elastic constant k of the yo-yo ball tether(m/k)) |
- |
500 |
|
- |
4.33 - 5.11.3(Straps intended to be worn fully or partially around the neck-breakaway feature separation test) |
- |
500 |
|
- |
4.34(Sledges and toboggans with cords for pulling) |
- |
500 |
|
- |
4.35.3 - 5.39(Jaw entrapment in handles and steering wheels-jaw entrapment test) |
- |
500 |
|
- |
9873 (Part - 2) 4.5 - 5.5(Soft-filled toys-Test for soft-filled toys
) |
- |
2000 |
|
- |
9873 (Part - 2) 4.5 - 5.5(Soft-filled toys-rate of spread of flame ) |
- |
2000 |
|
For Single unit |
9873 (Part - 2) 4.4(Toys intended to be entered by a child-rate of spread of flame-Test relating to flowing elements of toys to be worn on the head (except those
covered by 4.2.2 and 4.2.3), hoods, headdresses, etc. and masks not covered by 4.2.4 which partially or fully cover the head (e.g. fabric and cardboard masks, eye masks, face masks), toy disguise costumes and toys intended to be entered or worn by a child
) |
- |
2000 |
|
For Single unit |
9873 (Part - 2) 4.4 - 5.4(Toys intended to be entered by a child-rate of spread of flame-Test relating to flowing elements of toys to be worn on the head (except those
covered by 4.2.2 and 4.2.3), hoods, headdresses, etc. and masks not covered by 4.2.4 which partially or fully cover the head (e.g. fabric and cardboard masks, eye masks, face masks), toy disguise costumes and toys intended to be entered or worn by a child
) |
- |
2000 |
|
For Single unit |
9873 (Part - 2) 4.4 - 5.4(Toys intended to be entered by a child-rate of spread of flame) |
- |
2000 |
|
For Single unit |
9873 (Part - 2) 4.3(Toys to be worn on the head-Toy disguise costumes and toys intended to be worn by a child in play) |
- |
2000 |
|
For Single unit |
9873 (Part - 9) 3(Vinyl in any part of the toy or childcare article that can be placed in mouth of a child under 4 years of age - a) Di-iso-Nonyl Phthalate (DINP), b) Di-iso-Decyl Phthalate (DIDP), c) Di-n-Octyl Phthalate (DNOP) - IS 9873 Part 6) |
- |
5000 |
|
For Single unit |
9873 (Part - 9) 3(Vinyl in toys or childcare articles - a) Bis-(2-ethlyhexyl) Phthalates (DEHP), b) Di-Butyl phthalate (DBP), c) Benzyl butyl Phthalate (BBP) - IS 9873 Part 6) |
- |
5000 |
|
For Single unit |
9873 (Part - 9) 3(Vinyl in any part of the toy or childcare article that can be placed in mouth of a child under 4 years of age - a) Di-iso-Nonyl Phthalate (DINP), b) Di-iso-Decyl Phthalate (DIDP), c) Di-n-Octyl Phthalate (DNOP) - IS 9873 Part 6) |
- |
5000 |
|
For Single unit |
9873 (Part - 9) 3(Vinyl in toys or childcare articles - a) Bis-(2-ethlyhexyl) Phthalates (DEHP), b) Di-Butyl phthalate (DBP), c) Benzyl butyl Phthalate (BBP) - IS 9873 Part 6) |
- |
5000 |
|
For Single unit |
9873 (Part - 3) 4.1 - Table 1(Selenium (Se) - Cl 7,8,9 ) |
- |
3000 |
|
For Single unit |
9873 (Part - 3) 4.1 - Table 1(Mercury (Hg) - Cl 7,8,9 ) |
- |
3000 |
|
For Single unit |
9873 (Part - 3) 4.1 - Table 1(Lead (Pb) - Cl 7,8,9 ) |
- |
3000 |
|
For Single unit |
9873 (Part - 3) 4.1 - Table 1(Chromium (Cr) - Cl 7,8,9 ) |
- |
3000 |
|
For Single unit |
9873 (Part - 3) 4.1 - Table 1(Cadmium (Cd) - Cl 7,8,9) |
- |
3000 |
|
For Single unit |
9873 (Part - 3) 4.1 - Table 1(Barium (Ba) - Cl 7,8,9 ) |
- |
3000 |
|
For Single unit |
9873 (Part - 3) 4.1 - Table 1(Arsenic (As) - Cl 7,8,9 ) |
- |
3000 |
|
For Single unit |
9873 (Part - 3) 4.1 - Table 1(Antimony (Sb) - Cl 7,8,9) |
- |
3000 |
|
For Single unit |
5.24.6.1(Tension Test General procedure) |
- |
200 |
|
- |
4.1(Normal use) |
- |
200 |
|
- |
4.3.1(Material quality) |
- |
200 |
|
- |
4.1(General) |
- |
200 |
|
- |
|
19 Jul, 2027 |
- - |
803 |
EMC Testing and Compliance LLP, Gurugram
| 8141526
| IS 15298 : Part 2 (2024) |
Personal Protective Equipment Part 2 Safety Footwear (ISO 20345 : 2021, MOD) (Third Revision) |
- |
60000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
Cl 5.2(Design) |
- |
1000 |
|
- |
Cl 5.2.2, Table 4(" Height of upper
") |
- |
1000 |
|
- |
Cl 5.2.3(Heel area) |
- |
1000 |
|
- |
Cl 5.3.1.1(Construction of whole footwear) |
- |
1000 |
|
- |
Cl 5.3.1.2(Upper/outsole bond strength) |
- |
1000 |
|
- |
Cl 5.3.2.1(Toe protection - general) |
- |
1000 |
|
- |
Cl 5.3.2.2(Internal length) |
- |
1000 |
|
- |
Cl 5.3.2.3(Width of toecap flange) |
- |
1000 |
|
- |
Cl 5.3.2.4.1(Corrosion resistance of Class I footwear and hybrid mounted footwear) |
- |
1000 |
|
- |
Cl 5.3.2.4.2(Corrosion resistance of Class II and hybrid moulded footwear) |
- |
1000 |
|
- |
Cl 5.3.2.5(Behaviour of toecaps (thermal and chemical) of Corrosion resistance) |
- |
1000 |
|
- |
Cl 5.3.2.6(Impact resistance) |
- |
1000 |
|
- |
Cl 5.3.2.7(Compression resistance) |
- |
1000 |
|
- |
Cl 5.3.3(Leak proofness) |
- |
1000 |
|
- |
Cl 5.3.4("Specific ergonomic features
") |
- |
1000 |
|
- |
Cl 5.3.5.2, Table 7(Slip resistance on ceramic tile floor with sodium lauryl sulphate (NaLS) solution) |
- |
1000 |
|
- |
Cl 5.3.6, Table no 1 of IS 17011,(i)(Allergenic and carcinogenic disperse dyes) |
- |
1000 |
|
- |
Cl 5.3.6, Table no 1 of IS 17011 (ii)(Aromatic amines released from Azo dyes (each individual amine)) |
- |
1000 |
|
- |
Cl 5.3.6, Table no 1 of IS 17011 (iii)(Aromatic amines released from Azo dyes (each individual amine)) |
- |
1000 |
|
- |
Cl 5.3.6, Table no 1 of IS 17011 (iv)(Chromium (VI)) |
- |
1000 |
|
- |
Cl 5.3.6, Table no 1 of IS 17011 (v)(Dimethyl fumarate (DMFU)) |
- |
1000 |
|
- |
Cl 5.3.6, Table no1 of IS 17011 (vi)(Formaldehyde (free or released by partial hydrolysis)) |
- |
1000 |
|
- |
Cl 5.3.6, Table no 1 of IS 17011 (vii)(Formaldehyde) |
- |
1000 |
|
- |
Cl 5.3.6, Table no 1 of IS 17011 (viii)(Organotin compounds) |
- |
1000 |
|
- |
Cl 5.3.6, Table no 1 of IS 17011 (ix)(PCP-TeCP-TriCP polychlorophenols) |
- |
1000 |
|
- |
Cl 5.3.6, Table no 1 of IS 17011 (x)(pH) |
- |
1000 |
|
- |
Cl 5.3.6, Table no 1 of IS 17011 (xi)(Phthalates (each individual phthalate)) |
- |
1000 |
|
- |
Cl 5.3.6, Table no 1 of IS 17011 (xii)(Nickel, on skin contact) |
- |
1000 |
|
- |
Cl 5.3.7(Seam strength) |
- |
1000 |
|
- |
Cl 5.3.8(Lead Content ( National Annex A)) |
- |
1000 |
|
- |
Cl 5.4.1.1(Class I footwear, determination of the area where upper requirements apply of Upper) |
- |
1000 |
|
- |
Cl 5.4.1.2(Hybrid footwear, determination of the area where upper requirements apply of Upper) |
- |
1000 |
|
- |
Cl 5.4.2(Thickness) |
- |
1000 |
|
- |
Cl 5.4.3(Tear strength) |
- |
1000 |
|
- |
Cl 5.4.4, Table 11(Tensile properties- Tensile strength) |
- |
1000 |
|
- |
Cl 5.4.4, Table 11(Tensile properties- Breaking Force) |
- |
1000 |
|
- |
Cl 5.4.4, Table 11(Tensile properties-Modulus at 100 % elongation) |
- |
1000 |
|
- |
Cl 5.4.4, Table 11(Tensile properties- Elongation at break) |
- |
1000 |
|
- |
Cl 5.4.5(Flexing resistance) |
- |
1000 |
|
- |
Cl 5.4.6(Water vapour permeability and coefficient) |
- |
1000 |
|
- |
Cl 5.4.7(Resistance to hydrolysis) |
- |
1000 |
|
- |
Cl 5.5.2(Lining- Tear strength) |
- |
1000 |
|
- |
Cl 5.5.3(Lining- Abrasion resistance) |
- |
1000 |
|
- |
Cl 5.5.4(Lining-Water vapour permeability and coefficient) |
- |
1000 |
|
- |
Cl 5.6.2, Table 14(Tear strength of tongue) |
- |
1000 |
|
- |
Cl 5.7.1(Thickness of Insole, insock and footbed) |
- |
1000 |
|
- |
Cl 5.7.2(Water permeability of insock) |
- |
1000 |
|
- |
Cl 5.7.3(Water absorption and desorption of Insole, insock and footbed) |
- |
1000 |
|
- |
Cl 5.7.4.1(Abrasion resistance of Insoles) |
- |
1000 |
|
- |
Cl 5.7.4.2(Abrasion resistance of Insocks) |
- |
1000 |
|
- |
Cl 5.8.2.1, Table 15(Thickness of Outsole) |
- |
1000 |
|
- |
Cl 5.8.2.2(Cleated area) |
- |
1000 |
|
- |
Cl 5.8.2.3(Cleat height) |
- |
1000 |
|
- |
Cl 5.8.3(Outsole- Tear strength) |
- |
1000 |
|
- |
Cl 5.8.4(Outsole- Abrasion resistance) |
- |
1000 |
|
- |
Cl 5.8.5(Outsole-Flexing resistance) |
- |
1000 |
|
- |
Cl 5.8.6(Outsole-Resistance to hydrolysis) |
- |
1000 |
|
- |
Cl 5.8.7(Interlayer bond strength) |
- |
1000 |
|
- |
Cl 6.2.1.1.2(Metallic perforation-resistant inserts (Type P)) |
- |
1000 |
|
- |
Cl 6.2.1.1.3(Non-metallic perforation-resistant inserts and insoles (Type PL)) |
- |
1000 |
|
- |
Personal protective equipment: Part 2 safety footwear(Non-metallic perforation-resistant inserts and insoles (Type PS)) |
- |
1000 |
|
- |
Cl 6.2.1.2(Construction of perforation resistant insert) |
- |
1000 |
|
- |
Cl 6.2.1.3(Dimensions of perforation resistant insert) |
- |
1000 |
|
- |
Cl 6.2.1.4.1(Flex resistance of perforation-resistant inserts) |
- |
1000 |
|
- |
Cl 6.2.1.4.2.1(Corrosion resistance of perforation resistant metallic insert for Class I footwear and hybrid mounted footwear) |
- |
1000 |
|
- |
Cl 6.2.1.4.2.2(Corrosion resistance of perforation resistant metallic insert for Class II footwear and hybrid moulded footwear) |
- |
1000 |
|
- |
Cl 6.2.1.4.3(Stability against ageing and environmental influence of non-metallic perforationresistant inserts) |
- |
1000 |
|
- |
Cl 6.2.2.1(Electrical properties of Partially conductive footwear) |
- |
1000 |
|
- |
Cl 6.2.2.2(Electrical properties of Antistatic footwear) |
- |
1000 |
|
- |
Cl 6.2.3.1(Heat insulation of outsole complex) |
- |
1000 |
|
- |
Cl 6.2.3.2(Cold insulation of outsole complex) |
- |
1000 |
|
- |
Cl 6.2.5(Water resistance) |
- |
1000 |
|
- |
Cl 6.2.4(Energy absorption of seat region) |
- |
1000 |
|
- |
Cl 6.2.6.1(Metatarsal protection - Construction) |
- |
1000 |
|
- |
Cl 6.2.6.2("Metatarsal protection-Impact resistance of metatarsal protective device
") |
- |
1000 |
|
- |
Cl 6.2.7(Ankle protection) |
- |
1000 |
|
- |
Cl 6.2.8.2(Cut resistance footwear- design) |
- |
1000 |
|
- |
Cl 6.2.8.2(Dimensions and construction of protective area of Cut resistance footwear) |
- |
1000 |
|
- |
Cl 6.2.8.3(Resistance to cutting) |
- |
1000 |
|
- |
Cl 6.2.9(Scuff cap) |
- |
1000 |
|
- |
Cl 6.2.10 , Table 19("Slip resistance on ceramic tile floor with glycerine
") |
- |
1000 |
|
- |
Cl 6.3(Upper — Water penetration and absorption) |
- |
1000 |
|
- |
Cl 6.4.1(Resistance to hot contact - Outsole) |
- |
1000 |
|
- |
Cl 6.4.2(Resistance to fuel oil - Outsole) |
- |
1000 |
|
- |
Cl 6.4.3.1(Mechanical properties of Ladder grip) |
- |
1000 |
|
- |
Cl 6.4.3.2(Design of Ladder grip) |
- |
1000 |
|
- |
Cl 6.4.3.3(Cleat height in the waist area of Ladder grip) |
- |
1000 |
|
- |
Cl 6.4.3.4(Heel breast of Ladder grip) |
- |
1000 |
|
- |
Cl 7, Table 20("Marking
") |
- |
1000 |
|
- |
|
19 Jul, 2027 |
- - |
804 |
EMC Testing and Compliance LLP, Gurugram
| 8141526
| IS 15844 : Part 3 (2024) |
Sports Footwear Part 3 Professional Sports Footwear |
- |
50000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
Cl-6(Size and Fittings) |
- |
100 |
|
- |
Cl-5(Design) |
- |
100 |
|
- |
Cl-6(Size and Fittings) |
- |
100 |
|
- |
Cl.7.1.1(Upper to Mid Sole/Out Sole, Upper to Composite Sole (Applicable Only When the Sole is Composite) and Out Sole to Mid Sole (Multilayer, if Present), Bond Performance) |
- |
1080 |
|
- |
Cl.7.1.2(Energy Absorption at Seat Region) |
- |
700 |
|
- |
Cl.7.1.1(Upper to Mid Sole/Out Sole, Upper to Composite Sole (Applicable Only When the Sole is Composite) and Out Sole to Mid Sole (Multilayer, if Present), Bond Performance) |
- |
1080 |
|
- |
Cl.7.1.2(Energy Absorption at Seat Region) |
- |
700 |
|
- |
Cl.7.1.3(Complete Shoe Flexing) |
- |
1500 |
|
- |
Cl.7.1.4(Washability) |
- |
1000 |
|
- |
Cl.7.1.5(Slip Resistance) |
- |
2500 |
|
- |
Cl.7.1.6(Heel Drop) |
- |
180 |
|
- |
Cl.7.2 Table-2 S.No- (i)("Flexing resistance, Min
a) Dry condition
b) Wet condition") |
- |
1500 |
|
- |
Cl.7.2 Table-2 S.No- (ii)(Tear strength (average force), N, Min) |
- |
500 |
|
- |
Cl.7.2 Table-2 S.No- (iii)("Colour fastness rubbing
a-Dry
b-Wet") |
- |
500 |
|
- |
Cl.7.2 Table-2 S.No- (iv)("a) Water vapour permeability
b) Water vapour coefficient") |
- |
700 |
|
- |
Cl.7.2 Table-2 S.No- (v)(Stitch tear strength N/mm, Min) |
- |
500 |
|
- |
Cl.7.2 Table-2 S.No- (vii)(Tensile strength) |
- |
250 |
|
- |
Cl.7.2 Table-2 S.No- (viii)(Elongation at break, percent) |
- |
250 |
|
- |
Cl.7.2 Table-2 S.No- (ix)("Abrasion test
a) Dry
b) Wet") |
- |
1350 |
|
- |
Cl.7.2 Table-3 S.No- (i)(Breaking strength, N/mm, Min) |
- |
250 |
|
- |
Cl.7.2 Table-3 S.No- (ii)(Elongation at break, percent, Min) |
- |
250 |
|
- |
Cl.7.2 Table-3 S.No- (iii)(Tear strength, N, Min) |
- |
500 |
|
- |
Cl.7.2 Table-3 S.No- (iv)(Strength at needle perforation) |
- |
600 |
|
- |
Cl.7.2 Table-3 S.No- (v)("Flexing resistance
a-Dry condition, b) Wet condition") |
- |
1500 |
|
- |
Cl.7.2 Table-3 S.No- (vi)("a) Water vapour permeability
b) Water vapour coefficient") |
- |
700 |
|
- |
Cl.7.2 Table-3 S.No- (vii)(Hydrolysis resistance) |
- |
2700 |
|
- |
Cl.7.2 Table-3 S.No- (ix)(Bursting strength) |
- |
1000 |
|
- |
Cl.7.3 Table-4 S.No- (i)(Tear strength, N, Min) |
- |
500 |
|
- |
Cl.7.3 Table-4 S.No- (ii)("Abrasion resistance,
a) Dry
b) Wet
") |
- |
500 |
|
- |
Cl.7.3 Table-4 S.No- (iii)(Colour fastness to rubbing, grey scale rate with 10 rubs on dry or wet, Min) |
- |
300 |
|
- |
Cl.7.3 Table-4 S.No- (iv)(Colour fastness to perspiration (contact method) grey scale rate, Min) |
- |
500 |
|
- |
Cl.7.3 Table-4 S.No- (v)("a-Water vapour permeability
b-Water vapour coefficient") |
- |
700 |
|
- |
Cl.7.4 Table-5 S.No- (i)(Flexing index, Min) |
- |
800 |
|
- |
Cl.7.4 Table-5 S.No- (ii)(Abrasion resistance) |
- |
1350 |
|
- |
Cl.7.4 Table-5 S.No- (iii)("a) Water absorption
b) Water desorption") |
- |
700 |
|
- |
Cl.7.5 Table-6 S.No- (i)("Abrasion resistance
a) Dry condition
b) Wet condition") |
- |
1350 |
|
- |
Cl.7.5 Table-6 S.No- (ii)("a) Water absorption
b) Water desorption") |
- |
700 |
|
- |
Cl.7.5 Table-6 S.No- (iii)(Heat resistance shrinkage linear, percent, Max) |
- |
1000 |
|
- |
Cl.7.6 Table-7 S.No- (i)(Abrasion resistance) |
- |
1080 |
|
- |
Cl.7.6 Table-7 S.No- (ii)("Flexing resistance
a) Bennewart Method
b) Ross flexing method") |
- |
1080 |
|
- |
Cl.7.6 Table-7 S.No- (iii)(Hydrolysis resistance) |
- |
2700 |
|
- |
Cl.7.6 Table-7 S.No- (iv)(Tear strength, N/mm, Min) |
- |
500 |
|
- |
Cl.7.6 Table-7 S.No- (v)(Tensile strength) |
- |
250 |
|
- |
Cl.7.6 Table-7 S.No- (vi)(Elongation at break percent, Min) |
- |
250 |
|
- |
Cl.7.6 Table-7 S.No- (vii)(Compression set percent, Max) |
- |
1000 |
|
- |
Cl.7.7 Table-8 S.No- (i)("Compression set, percent, Max
a) For EVA
b) For all other material") |
- |
1000 |
|
- |
Cl.7.7 Table-8 S.No- (ii)(Split tear strength) |
- |
500 |
|
- |
Cl.7.7 Table-8 S.No- (iii)(Heat shrinkage, percent, Ma) |
- |
1000 |
|
- |
Cl.7.7 Table-8 S.No- (iii)(Elongation at break, percent, Min) |
- |
250 |
|
- |
Cl.7.7 Table-8 S.No- (iv)(Elongation at break, percent, Min) |
- |
250 |
|
- |
Cl.7.8 Table-9 S.No- (i)(First dry collapsing load, hardness, N, Min) |
- |
800 |
|
- |
Cl.7.8 Table-9 S.No- (ii)(Resilience, percent, Min) |
- |
800 |
|
- |
Cl.7.8 Table-9 S.No- (iii)(Moisture resistance, percent, Min) |
- |
800 |
|
- |
Cl.7.8 Table-9 S.No- (iv)("a) Initial dry area shape retention, percent, Min
b) Area shape retention after 10th
collapse, dry, percent, Min
") |
- |
800 |
|
- |
Cl.7.8 Table-9 S.No- (v)(Peel strength, N/nm, Min) |
- |
1080 |
|
- |
Cl.7.9 Table-10 S.No- (i)("Peel strength, N/mm, Min
a) Initial
b) After 5 000 wear cycles") |
- |
1500 |
|
- |
Cl.7.9 Table-10 S.No- (ii)("Shear strength, kPa, Min
a) Initial
b) After 5 000 wear cycles") |
- |
1500 |
|
- |
Cl.7.10 Table-11 S.No- (i)(Limit of useful extension, percent, Min) |
- |
1000 |
|
- |
Cl.7.10 Table-11 S.No- (ii)(Needle strength, N/mm, Min) |
- |
600 |
|
- |
Cl.7.11 Table-12 S.No- (i)(Breaking strength of lace) |
- |
250 |
|
- |
Cl.7.11 Table-12 S.No- (ii)(Lace tag strength) |
- |
250 |
|
- |
Cl.7.11 Table-12 S.No- (iii)(Lace to lace abrasion) |
- |
800 |
|
- |
Cl.7.11 Table-12 S.No- (iv)(Colour fastness to water (for lace) (Contact method)) |
- |
500 |
|
- |
Cl.7.11 Table-12 S.No- (v)(Strength of buckle/ski hook/D-ring,) |
- |
800 |
|
- |
Cl.7.11 Table-12 S.No- (vi)("Corrosion resistance (applicable for all including decorative metal part)
") |
- |
900 |
|
- |
Cl.7.11 Table-13 S.No- (i)(Corrosion resistance (applicable for metallic spikes)) |
- |
900 |
|
- |
Cl-7.12.1, Table no. 1 of IS 17011,(i)(Allergenic and carcinogenic disperse dyes) |
- |
4500 |
|
- |
Cl-7.12.1, Table no. 1 of IS 17011,(ii)(Aromatic amines released from Azo dyes (each individual amine)) |
- |
2000 |
|
- |
Cl-7.12.1, Table no. 1 of IS 17011,(iii)(Aromatic amines released from Azo dyes (each individual amine)) |
- |
2000 |
|
- |
Cl-7.12.1, Table no. 1 of IS 17011,(iv)(Chromium (VI)) |
- |
1350 |
|
- |
Cl-7.12.1, Table no. 1 of IS 17011,(v)(Dimethyl fumarate (DMFU)) |
- |
3700 |
|
- |
Cl-7.12.1, Table no. 1 of IS 17011,(vi)(Formaldehyde (free or released by partial hydrolysis)) |
- |
2500 |
|
- |
Cl-7.12.1, Table no. 1 of IS 17011,(vii)(Formaldehyde) |
- |
2500 |
|
- |
Cl-7.12.1, Table no. 1 of IS 17011,(viii)(Organotin compounds) |
- |
3600 |
|
- |
Cl-7.12.1, Table no. 1 of IS 17011,(ix)(PCP-TeCP-TriCP polychlorophenols) |
- |
3000 |
|
- |
Cl-7.12.1, Table no. 1 of IS 17011,(viii)(Organotin compounds) |
- |
3600 |
|
- |
Cl-7.12.1, Table no. 1 of IS 17011,(vi)(Formaldehyde (free or released by partial hydrolysis)) |
- |
2500 |
|
- |
Cl-7.12.1, Table no. 1 of IS 17011,(v)(Dimethyl fumarate (DMFU)) |
- |
3700 |
|
- |
Cl-7.12.1, Table no. 1 of IS 17011,(iv)(Chromium (VI)) |
- |
1350 |
|
- |
Cl-7.12.1, Table no. 1 of IS 17011,(x)(pH) |
- |
300 |
|
- |
Cl-7.12.1, Table no. 1 of IS 17011,(xi)(Phthalates (each individual phthalate)) |
- |
3600 |
|
- |
C-7.12.1, Table no. 1 of IS 17011,(xii)(Nickel, on skin contact 2-(thiocyanomethylthio) -benzothiazole (TCMTB)) |
- |
1500 |
|
- |
Cl-7.12.2(PVC is present in sports shoe) |
- |
500 |
|
- |
Cl- 8.1(Marking) |
- |
150 |
|
- |
|
19 Jul, 2027 |
- - |
805 |
EMC Testing and Compliance LLP, Gurugram
| 8141526
| IS 17043 : Part 2 (2024) |
Shoes: Shoes for General Purpose |
- |
45000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
Cl-5.1(Shape and Design) |
- |
100 |
|
- |
Cl-5.3(Material) |
- |
100 |
|
- |
Cl-5.4, Table-1 (i)(Bond strength, N/mm, Min Upper to outsole, N/mm, Min) |
- |
1080 |
|
- |
Cl-5.4, Table-1 (ii)(Inter layer bond strength,= N/mm, Min Midsole to outsole, N/mm, Min) |
- |
1080 |
|
- |
Cl-5.4, Table-1 (iii)(Whole shoe flexing, flexes) |
- |
1080 |
|
- |
Cl-5.4, Table-1 (iv)(Water proofness on complete shoe) |
- |
1500 |
|
- |
Cl-5.4, Table-1 (v)(Slip resistance, Cof(1), Min dry and wet* (quarry tile)) |
- |
2500 |
|
- |
Cl-5.4, Table-1 (vi)(Attachment strength of strap and buckle/D-ring N) |
- |
800 |
|
- |
Cl-5.4, Table-1 (vii)(Attachment strength of strap and velcro , N, Min) |
- |
1000 |
|
- |
Cl-5.4, Table-1 (viii)(Strength of eyelet attachment, N, Min) |
- |
100 |
|
- |
Cl-5.4, Table-1 (ix)(Heel pull off strength, N, Min) |
- |
1200 |
|
- |
Cl-5.4, Table-1 (x)(Top piece attachment strength, N, Min) |
- |
800 |
|
- |
Cl-5.4, Table-1 (xi)(Seam strength, N/mm, Min) |
- |
900 |
|
- |
Cl-5.4, Table-1 (xii)(Whole shoe topline strength, N, Min) |
- |
800 |
|
- |
Cl-5.4, Table-1 (xiii)(Abrasion resistance (volume loss), mm3) |
- |
1080 |
|
- |
Cl-5.4, Table-1 (xiv)(Chemical requirements(3)) |
- |
30000 |
|
- |
Cl-5.4, Table-1 (xv)(Lead content (as Pb) ppm, Max) |
- |
630 |
|
- |
Cl-5.4, Table-1 (xvi)(Hydrolysis resistance,(4) cut growth at 150 000 flexes, mm, Max) |
- |
2700 |
|
- |
Cl-6.1.1, Table-2 (i)(Tear trength, N) |
- |
500 |
|
- |
Cl-6.1.1, Table-2 (ii)(Flexing resistance, flexes) |
- |
1080 |
|
- |
Cl-6.1.1, Table-2 (iii)(Colour fastness to rubbing (marring/staining)) |
- |
1000 |
|
- |
Cl-6.1.1, Table-2 (iv)(Colour fastness to water (contact method- multi fabrics)) |
- |
1000 |
|
- |
Cl-6.1.1, Table-2 (v)(Water vapour permeability,mg/cm2 /h, Min Water vapour coefficient,mg/cm2 , Min) |
- |
700 |
|
- |
Cl-6.1.1, Table-2 (vi)(Stitch tear strength, N/mm, Min) |
- |
500 |
|
- |
Cl-6.1.3, Table- 4 (vii)(Abrasion resistance) |
- |
1080 |
|
- |
Cl-6.1.2, Table-3 (i)(Colour fastness to light, Marring, Min) |
- |
1000 |
|
- |
Cl-6.1.2, Table-3 (ii)(Water resistance) |
- |
1000 |
|
- |
Cl-6.1.2, Table-3 (iii)(Flexing resistance, flexes at (-) 5 °C 25 000 flexes) |
- |
1080 |
|
- |
Cl-6.1.3, Table- 4 (i)(Breaking strength, N/mm, Min Elongation at break, percent, Min) |
- |
250 |
|
- |
Cl-6.1.3, Table- 4 (ii)(Tear Strength, N, Min) |
- |
500 |
|
- |
Cl-6.1.3, Table- 4 (iii)(Strength at needle perforation, N/mm, Min) |
- |
600 |
|
- |
Cl-6.1.3, Table- 4 (iv)(Flexing resistance, Flexes) |
- |
1500 |
|
- |
Cl-6.1.3, Table- 4 (v)(Water vapour permeability (WVP), mg/cm2 /h, Min) |
- |
700 |
|
- |
Cl-6.1.3, Table- 4 (vi)(Hydrolysis resistance) |
- |
2700 |
|
- |
Cl-6.1.4, Table-5 (i)(Colour fastness to light, Marring, Min) |
- |
1000 |
|
- |
Cl-6.1.4, Table- 5 (ii)(Flexing resistance, flexes at (-) 5 ºC, s 25 000 flexes) |
- |
1500 |
|
- |
Cl-6.2, Table-6 (i)(Tear strength, N, Min) |
- |
500 |
|
- |
Cl-6.2, Table-6 (ii)(Abrasion resistance) |
- |
1080 |
|
- |
Cl-6.2, Table-6 (iii)(Colour fastness rubbing (crocking)) |
- |
1000 |
|
- |
Cl-6.2, Table-6 (iv)(Colour fastness to perspiration) |
- |
1000 |
|
- |
Cl-6.2, Table-6 (v)(Water vapour permeability, mg/cm2 /h, Min Water vapour coefficient, mg/cm2, Min) |
- |
700 |
|
- |
Cl-6.3, Table-7 (i)(Flexing index, Min) |
- |
800 |
|
- |
Cl-6.3, Table-7 (ii)(Abrasion resistance at 400 cycles) |
- |
1080 |
|
- |
Cl-6.3, Table-7 (iii)(Water absorption, mg/cm2 , Min
Water desorption, percent, Min) |
- |
700 |
|
- |
Cl-6.4, Table-8 (i)(Thickness, mm, Min) |
- |
180 |
|
- |
Cl-6.4, Table-8 (ii)(Abrasion resistance) |
- |
1080 |
|
- |
Cl-6.4, Table-8 (iii)(Water absorption, mg/cm2 , Min
Water desorption, percent, Min) |
- |
700 |
|
- |
Cl-6.5.1, , Table-9 (i)(Flexing resistance) |
- |
1080 |
|
- |
Cl-6.5.1, , Table-9 (ii)(Hydrolysis resistance, cut growth at 150 000 flexes, mm, Max) |
- |
2700 |
|
- |
Cl-6.5.1, , Table-9 (iii)(Compression set, percent, Max) |
- |
1000 |
|
- |
Cl-6.5.2.1, Table-10 (i)(Grain crack index, Min) |
- |
900 |
|
- |
Cl-6.5.2.1, Table-10 (ii)(Density, g/cm3 , Min) |
- |
300 |
|
- |
Cl-6.5.2.1, Table-10 (iii)(Abrasion resistance, mm/kcs, Max) |
- |
1080 |
|
- |
Cl-6.5.2.2, Table-11 (i)(Water resistance, (dynamic method)) |
- |
1000 |
|
- |
Cl-6.5.2.3, Table-12 (i)(Hardness, Min) |
- |
600 |
|
- |
Cl-6.5.2.3, Table-12 (ii)(Density, g/cm3 , Max) |
- |
300 |
|
- |
Cl-6.5.2.3, Table-12 (iii)(Abrasion resistance (volume loss), mm3 , Max) |
- |
1080 |
|
- |
Cl-6.5.2.3, Table-12 (iv)(Bond Strength between Rubber top-lift and adjacent material, N/mm, Min) |
- |
1080 |
|
- |
Cl-6.6, Table-13 (i)(Heat shrinkage, percent, Max) |
- |
1000 |
|
- |
Cl-6.6, Table-13 (ii)(Split tear strength, kg/25 mm, Min) |
- |
500 |
|
- |
Cl-6.6, Table-13 (iii)(Compression set, percent, Max) |
- |
1000 |
|
- |
Cl-6.7, Table-14 (i)(Hardness, N) |
- |
600 |
|
- |
Cl-6.7, Table-14 (ii)(Resilience, percent) |
- |
800 |
|
- |
Cl-6.7, Table-14 (iii)(Moisture resistance, percent) |
- |
800 |
|
- |
Cl-6.10, Table-17 (i)(Lace breaking strength, N, Min) |
- |
250 |
|
- |
Cl-6.10, Table-17 (ii)(Lace tag strength, N, Min) |
- |
250 |
|
- |
Cl-6.10, Table-17 (iii)(Lace to lace abrasion resistance, cycles) |
- |
800 |
|
- |
Cl-6.10, Table-17 (iv)(Colour fastness to water for lace contact methodstaining Gray scale rate , Min) |
- |
500 |
|
- |
Cl-6.10, Table-17 (v)(Corrosion resistance) |
- |
900 |
|
- |
Cl-6.11, Table-18 (i)(Fatigue resistance, cycles, Min) |
- |
1500 |
|
- |
Cl-6.11, Table-18 (ii)(Security of puller attachment strength, N, Min) |
- |
800 |
|
- |
Cl-6.11, Table-18 (iii)(Lateral load, N, Min) |
- |
800 |
|
- |
Cl-6.11, Table-18 (iv)(End attachment strength, N, Min) |
- |
800 |
|
- |
Cl-8.1(Marking) |
- |
150 |
|
- |
Cl-6.7, Table-14 (iv)(Area shape retention, percent
(a) Initial, Min
b) After 10 collapsing load, Min) |
- |
800 |
|
- |
Cl-6.7, Table-14 (v)(Adhesion strength, N/mm) |
- |
1080 |
|
- |
Cl-6.8, Table-15 (i)(Peel strength, N/mm
a) Initial, Min
b) After 5 000 wear cycles, Min) |
- |
1500 |
|
- |
Cl- 6.8, Table-15 (ii)(a) Shear strength, kPa
b) Initial, Min) |
- |
1500 |
|
- |
Cl- 6.9, Table-16 (i)(Limit of useful extension, percent,
Min) |
- |
1000 |
|
- |
Cl- 6.9, Table-16 (ii)(Needle strength, N/mm, Min) |
- |
600 |
|
- |
Cl-6.1.1, Table-2 (vii)(Abrasion resistance) |
- |
1080 |
|
- |
|
19 Jul, 2027 |
- - |
806 |
EMC Testing and Compliance LLP, Gurugram
| 8141526
| IS 15844 : Part 1 (2023) |
SPORTS FOOTWEAR PART -1 GENERAL PURPOSEFirst Revision |
- |
63000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
Cl No.4.1(Sampling and Conditioning) |
- |
180 |
|
- |
Cl No.4.2(Construction) |
- |
100 |
|
- |
Cl No.4.3(Whole Footwear) |
- |
100 |
|
- |
4.3.1(Insole) |
- |
100 |
|
- |
4.3.2(Toe spring height) |
- |
180 |
|
- |
4.3.3(Upper to Mid Sole/Out Sole Bond Performance) |
- |
1080 |
|
- |
4.3.4("Upper to Composite Sole Bond Performance
(Applicable Only When the Sole is Composite)") |
- |
1080 |
|
- |
4.3.5(Out Sole to Mid Sole (Multilayer) Bond Performance) |
- |
1080 |
|
- |
4.3.6(Energy Absorption at Seat Region) |
- |
630 |
|
- |
4.3.7(Complete Shoe Flexing) |
- |
1500 |
|
- |
4.3.8(Washability) |
- |
1000 |
|
- |
4.3.9(Slip Resistance) |
- |
2500 |
|
- |
Cl No.4.4 , Table No. 2 , i) , a)(Flexing resistance, Dry condition) |
- |
1500 |
|
- |
Cl No.4.4 , Table No. 2 , i) , b)(Flexing resistance, Wet condition) |
- |
1500 |
|
- |
Cl No.4.4 , Table No. 2 , ii)(Tear strength (average force), Min, N) |
- |
500 |
|
- |
Cl No.4.4 , Table No. 2 , iii) , a)("Colour fastness rubbing (To and fro) Grey scale rate, Min ,
Dry: (rubbing) Rating: (Marring and staining) ") |
- |
500 |
|
- |
Cl No.4.4 , Table No. 2 , iii) , b)("Colour fastness rubbing (To and fro) Grey scale rate, Min ,
Wet: (rubbing) Rating: (Marring and staining)") |
- |
500 |
|
- |
Cl No.4.4 , Table No. 2 , iv) , a)(Water vapour permeability, mg/cm2h, Min) |
- |
700 |
|
- |
Cl No.4.4 , Table No. 2 , iv) , b)(Water vapour coefficient, mg/cm2 , Min) |
- |
700 |
|
- |
Cl No.4.4 , Table No. 2 , v)(Stitch tear strength (double hole), N/mm, Min) |
- |
500 |
|
- |
Cl No.4.4 , Table No. 2 , vi)("Colour fastness to light (Optional) Grey scale rate,
Min Rating: (Marring)") |
- |
1000 |
|
- |
Cl No.4.4 , Table No. 2 , i)(Breaking strength, N/mm, Min) |
- |
500 |
|
- |
Cl No.4.4 , Table No. 2 , ii)(Elongation at break, percent Min) |
- |
500 |
|
- |
Cl No.4.4 , Table No. 2 , iii)(Tear strength, N, Min For Fabric: For all other materials) |
- |
500 |
|
- |
Cl No.4.4 , Table No. 2 , iv) , a)(Flexing resistance, Dry condition) |
- |
1500 |
|
- |
Cl No.4.4 , Table No. 2 , iv) , b)(Flexing resistance, ,Wet condition) |
- |
1500 |
|
- |
Cl No.4.4 , Table No. 2 , v) , a)(Water vapour permeability, mg/cm2h, Min) |
- |
700 |
|
- |
Cl No.4.4 , Table No. 2 , v) , b)("Water vapour coefficient, mg/cm2 , Min
") |
- |
700 |
|
- |
Cl No.4.6 , Table No. 4 , i)(Thickness, mm, Min) |
- |
180 |
|
- |
Cl No.4.6 , Table No. 4 , ii)(Flexing index, Min) |
- |
500 |
|
- |
Cl No.4.6 , Table No. 4 , iii)(Abrasion resistance, at 400 cycles) |
- |
1350 |
|
- |
Cl No.4.6 , Table No. 4 , iv) , a)(Water Absorption, mg/cm2 , Min) |
- |
700 |
|
- |
Cl No.4.6 , Table No. 4 , iv) , b)(Water Desorption, percent, Min) |
- |
700 |
|
- |
Cl No.4.7, Table No. 5 , i)(Thickness, mm, Min) |
- |
180 |
|
- |
Cl No.4.7, Table No. 5 , ii)(Abrasion resistance, cycles) |
- |
1080 |
|
- |
Cl No.4.7, Table No. 5 , iii) , a)(Water Absorption, mg/cm2 , Min) |
- |
700 |
|
- |
Cl No.4.7, Table No. 5 , iii) , b)(Water Desorption, percent, Min) |
- |
700 |
|
- |
Cl No.4.8 , Table No. 6 , i)(Abrasion resistance (Volume loss), mm3 , Max) |
- |
1080 |
|
- |
Cl No.4.8 , Table No. 6 , ii)("Flexing resistance Belt Method at 90 diameter Mandrel
or
Bennewart method, cut growth, Max") |
- |
1080 |
|
- |
Cl No.4.8 , Table No. 6 , iii)("Hydrolysis resistance, cut growth after 150 000
flexes, in mm, Max") |
- |
2700 |
|
- |
Cl No.4.9 , Table No. 7 , i)(Compression set, percent, Max) |
- |
1000 |
|
- |
Cl No.4.9 , Table No. 7 , ii)(Split tear strength, kg/25 mm, Min) |
- |
500 |
|
- |
Cl No.4.9 , Table No. 7 , iii)(Heat shrinkage, percent, Max) |
- |
1000 |
|
- |
Cl No.4.10 , Table No. 8 , i)(First dry collapsing load, hardness, N, Min) |
- |
800 |
|
- |
Cl No.4.10 , Table No. 8 , ii)(Resilience, percent, Min) |
- |
800 |
|
- |
Cl No.4.10 , Table No. 8 , iii)(Moisture resistance, percent, Min) |
- |
800 |
|
- |
Cl No.4.10 , Table No. 8 , iv) , a)(Initial dry area shape retention, percent, Min) |
- |
800 |
|
- |
Cl No.4.11 , Table No. 9 , i)(Peel strength, N/mm, Min) |
- |
1500 |
|
- |
Cl No.4.11 , Table No. 9 , ii)(Shear strength, kPa , Min) |
- |
1500 |
|
- |
Cl No.4.12 , Table No. 10 , i)(Limit of useful extension, percent, Min) |
- |
1000 |
|
- |
Cl No.4.13 , Table No. 11 , i)(Breaking strength of lace, N, Min) |
- |
800 |
|
- |
Cl No.4.13 , Table No. 11 , ii)(Lace tag strength, N, Min) |
- |
800 |
|
- |
Cl No.4.13 , Table No. 11 , iii)(Lace to lace abrasion,) |
- |
1000 |
|
- |
Cl No.4.13 , Table No. 11 , iv)("Colour fastness to water
Gray Scale Rate, Min Rating") |
- |
500 |
|
- |
Cl No.4.13 , Table No. 11 , v)(Strength of Buckle/Ski hook, N, Min) |
- |
800 |
|
- |
Cl No.4.13 , Table No. 11 , vi)(Corrosion resistance) |
- |
900 |
|
- |
Cl No . 4.14("Chemical Requirement on Complete Product
for all Types of Sports Shoe") |
- |
35000 |
|
with chemical test 63000; without 28000 per sample
10% discount to BIS |
Cl No . 5(MARKING AND PACKING) |
- |
180 |
|
- |
Cl No . 4.14, Table no. 1 of IS 17011(i)(Allergenic and carcinogenic disperse dyes) |
- |
4500 |
|
- |
Cl No . 4.14, Table no. 1 of IS 17011(ii)(Aromatic amines released from Azo dyes (each individual amine)) |
- |
3700 |
|
- |
Cl No . 4.14, Table no. 1 of IS 17011(iv)(Chromium (VI)) |
- |
2100 |
|
- |
Cl No . 4.14, Table no. 1 of IS 17011(v)(Dimethyl fumarate (DMFU)) |
- |
5000 |
|
- |
Cl No . 4.14, Table no. 1 of IS 17011(vi)(Formaldehyde (free or released by partial hydrolysis)) |
- |
2500 |
|
- |
Cl No . 4.14, Table no. 1 of IS 17011(vii)(Formaldehyde) |
- |
2500 |
|
- |
Cl No . 4.14, Table no. 1 of IS 17011(viii)(Organotin compounds) |
- |
7000 |
|
- |
Cl No . 4.14, Table no. 1 of IS 17011(ix)(PCP-TeCP-TriCP polychlorophenols) |
- |
4500 |
|
- |
Cl No . 4.14, Table no. 1 of IS 17011(x)(pH) |
- |
500 |
|
- |
Cl No . 4.14, Table no. 1 of IS 17011(xi)(Phthalates (each individual phthalate)) |
- |
6000 |
|
- |
Cl No . 4.14, Table no. 1 of IS 17011(xii)(Nickel, on skin contact 2-(thiocyanomethylthio) -benzothiazole (TCMTB)) |
- |
3500 |
|
- |
Cl-5, Table -1 S. No-(i) (Amendment No-1)(Insole) |
- |
100 |
|
- |
Cl-5, Table -1 S. No- (ii) (Amendment No-1)(Toe spring height) |
- |
180 |
|
- |
Cl-5, Table -1 S. No- (iii) (Amendment No-1)("Bond performance
(a) Upper to sole/mid sole/composite sole
(b) Interlayer bond strength") |
- |
2160 |
|
- |
Cl-5, Table -1 S. No- (iv) (Amendment No-1)(Energy absorption at seat region) |
- |
630 |
|
- |
Cl-5, Table -1 S. No- (v) (Amendment No-1)(Complete shoe flexing) |
- |
1500 |
|
- |
Cl-5, Table -1 S. No-(vi) (Amendment No-1)(Washability) |
- |
1000 |
|
- |
Cl-5, Table -1 S. No- (vii) (Amendment No-1)(Slip resistance, coefficient of friction (COF),) |
- |
2500 |
|
- |
Cl-5, Table -1 S. No- (viii) (Amendment No-1)("Abrasion resistance
a-Cellular sole
b-Solid sole") |
- |
1500 |
|
- |
Cl-5, Table -1 S. No- (x) (Amendment No-1)(Chemical requirements) |
- |
35000 |
|
- |
Cl-5, Table -1 S. No- (xi) (Amendment No-1)(Hydrolysis resistance) |
- |
2700 |
|
- |
Cl-5, Table -1 S. No- (xii) (Amendment No-1)(Lead content) |
- |
650 |
|
- |
Cl-6, Table -2 S. No- (i) (Amendment No-1)(Tear strength) |
- |
500 |
|
- |
Cl-6, Table -2 S. No- (ii) (Amendment No-1)("Colour fastness rubbing
a-Dry: (rubbing)
b-Wet: (rubbing)") |
- |
500 |
|
- |
Cl-6, Table -4 S. No- (iii),(Amendment No-1)(Colour fastness to rubbing , grey scale rate with 10 rubs on dry or wet, Min) |
- |
500 |
|
- |
Cl-6, Table -2 S. No- (iii), b) (Amendment No-1)(Water vapour coefficient) |
- |
630 |
|
- |
Cl-6, Table -2 S. No- (iv),(Amendment No-1)(Stitch tear strength) |
- |
500 |
|
- |
Cl-6, Table -2 S. No- (v),(Amendment No-1)(Colour fastness to light grey scale rate,) |
- |
1000 |
|
- |
Cl-6, Table -3 S. No- (i),(Amendment No-1)(Breaking strength, N/mm, Min) |
- |
500 |
|
- |
Cl-6, Table -3 S. No- (ii),(Amendment No-1)("Elongation at break
a-Tighter direction
b-Stretch direction") |
- |
500 |
|
- |
Cl-6, Table -5 S. No-(iii), (Amendment No-1)(Abrasion resistance,) |
- |
1350 |
|
- |
Cl-6, Table -5 S. No- (iv), a (Amendment No-1)(Water absorption) |
- |
630 |
|
- |
Cl-6, Table -6 S. No- (i), (Amendment No-1)(Thickness, mm, Min) |
- |
100 |
|
- |
Cl-6, Table -6 S. No- (ii), (Amendment No-1)("Abrasion resistance, cycles
a- Dry condition
b-Wet condition") |
- |
1080 |
|
- |
Cl-6, Table -6 S. No- (iii),a (Amendment No-1)(Water absorption) |
- |
350 |
|
- |
Cl-6, Table -6 S. No- (iv), b (Amendment No-1)(Water desorption, percent) |
- |
350 |
|
- |
Cl-6, Table -7 S. No- (i), (Amendment No-1)(Flexing resistance (Belt method or Bennewart method)) |
- |
1080 |
|
- |
Cl-6, Table -7 S. No- (ii), (Amendment No-1)(Hydrolysis resistance, cut growth after flexes) |
- |
2700 |
|
- |
Cl-6, Table -8 S. No- (i), (Amendment No-1)("Compression set, percent, Max
a) For EVA
b) For all other materials") |
- |
1000 |
|
- |
Cl-6, Table -8 S. No- (ii), (Amendment No-1)(Split tear strength) |
- |
500 |
|
- |
Cl-6, Table -8 S. No- (iii), (Amendment No-1)(Heat shrinkage) |
- |
1000 |
|
- |
Cl-6, Table -9 S. No- (i), (Amendment No-1)(First dry collapsing load, hardness) |
- |
800 |
|
- |
Cl-6, Table -9 S. No- (ii), (Amendment No-1)(Resilience, percent) |
- |
800 |
|
- |
Cl-6, Table -9 S. No- (iii), (Amendment No-1)(Moisture resistance) |
- |
800 |
|
- |
Cl-6, Table -9 S. No- (iv), a (Amendment No-1)(Initial dry area shape retention) |
- |
800 |
|
- |
Cl-6, Table -10 S. No- (i), (Amendment No-1)("Peel strength
a) Initial
b) After 5 000 wear cycles") |
- |
1500 |
|
- |
Cl-6, Table -10 S. No- (ii), (Amendment No-1)("Shear strength
a) Initial
b) After 5 000 wear cycles") |
- |
1500 |
|
- |
Cl-6, Table -11 S. No- (i), (Amendment No-1)(Limit of useful extension) |
- |
1000 |
|
- |
Cl-6, Table -12 S. No- (i), (Amendment No-1)(Breaking strength of lace) |
- |
500 |
|
- |
Cl-6, Table -12 S. No- (ii), (Amendment No-1)(Lace tag strength) |
- |
500 |
|
- |
Cl-6, Table -12 S. No- (iii), (Amendment No-1)(Lace to lace abrasion) |
- |
800 |
|
- |
Cl-6, Table -12 S. No- (iv), (Amendment No-1)(Colour fastness to water (for lace) (contact method)) |
- |
500 |
|
- |
Cl-6, Table -12 S. No (v), (Amendment No-1)(Strength of buckle/ski hook) |
- |
800 |
|
- |
Cl-6, Table -12 S. No- (vi), (Amendment No-1)(Corrosion resistance) |
- |
900 |
|
- |
|
19 Jul, 2027 |
- - |
807 |
Bharat Test House Pvt. Ltd. 1668 Sonipat
| 9168306
| IS 17813 (2022) |
Multi Layer Polyethylene-Stainless Steel Stainless Steel Pliable Corrugated Gas Tubing Kits in Buildings Indoor Outdoor with an Operating Pressure up to 5 Kgcm 5 bar Specification |
- |
25000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
Clause-5.1(General) |
- |
1000 |
|
- |
Clause-5.2(Tightness) |
- |
500 |
|
- |
Clause-5.3(Dimensional Check) |
- |
500 |
|
- |
Clause-5.4(Bending Performance) |
- |
500 |
|
- |
Clause-5.5(Crushing Resistance) |
- |
1500 |
|
- |
Clause-5.6(Stability under Pressure) |
- |
1500 |
|
- |
Clause-5.7(Wear Resistance of Outer Cover) |
- |
1000 |
|
- |
Clause-5.9(Impact Resistance) |
- |
1000 |
|
- |
Clause-5.10(Penetration Resistance) |
- |
1000 |
|
- |
Clause-5.11(Resistance to Pullout) |
- |
1500 |
|
- |
Clause-5.12(Chemical Resistance) |
- |
4000 |
|
- |
Clause-7.2(Marking, Labeling and Packaging) |
- |
500 |
|
- |
Clause-4.12.2.11(Torque test (End fittings bodies manufactured from more than one part)) |
- |
500 |
|
- |
|
26 Jul, 2027 |
- Included w.e.f.10.07.2025 |
808 |
Conformity Testing Labs Pvt. Ltd. Unit 2 (A33)
| 8139626
| IS 302 : Part 1 (2024) |
Household and Similar Electrical Appliances â Safety Part 1 General Requirements (Seventh Revision) |
- |
275000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
12(Charging of metal-ion batteries) |
- |
20000 |
|
Reduced Charges may apply for non complex Product depending upon parameters not applicable |
19.11.4.6(Class 3 Voltage dips and interruptions) |
- |
15000 |
|
Reduced Charges may apply for non complex Product depending upon parameters not applicable |
19.11.4.4(Surge immunity test) |
- |
15000 |
|
Reduced Charges may apply for non complex Product depending upon parameters not applicable |
19.11.4.3(Fast transient bursts) |
- |
15000 |
|
Reduced Charges may apply for non complex Product depending upon parameters not applicable |
19.11.4.1(Electrostatic discharges) |
- |
15000 |
|
Reduced Charges may apply for non complex Product depending upon parameters not applicable |
11.8(Temperature rise) |
- |
5000 |
|
Reduced Charges may apply for non complex Product depending upon parameters not applicable |
11.7(Duration corresponding) |
- |
5000 |
|
Reduced Charges may apply for non complex Product depending upon parameters not applicable |
11.6(Combined appliances) |
- |
5000 |
|
Reduced Charges may apply for non complex Product depending upon parameters not applicable |
11.5(Motor-operated appliances) |
- |
5000 |
|
Reduced Charges may apply for non complex Product depending upon parameters not applicable |
11.4(Heating appliances) |
- |
5000 |
|
Reduced Charges may apply for non complex Product depending upon parameters not applicable |
8.1.5(Live parts of built-in appliances) |
- |
5000 |
|
Reduced Charges may apply for non complex Product depending upon parameters not applicable |
17(Overload protection of transformers and associated circuits) |
- |
5000 |
|
Reduced Charges may apply for non complex Product depending upon parameters not applicable |
16(Leakage current and electric strength) |
- |
5000 |
|
Reduced Charges may apply for non complex Product depending upon parameters not applicable |
31(Resistance to Rusting) |
- |
5000 |
|
Reduced Charges may apply for non complex Product depending upon parameters not applicable |
30.2(Needle Flame Test) |
- |
5000 |
|
Reduced Charges may apply for non complex Product depending upon parameters not applicable |
30.2(Glow Wire Test) |
- |
5000 |
|
Reduced Charges may apply for non complex Product depending upon parameters not applicable |
30.1(Ball pressure test) |
- |
5000 |
|
Reduced Charges may apply for non complex Product depending upon parameters not applicable |
29(clearance, creepage distances and solid insulation) |
- |
5000 |
|
Reduced Charges may apply for non complex Product depending upon parameters not applicable |
28(Screw test and connections) |
- |
5000 |
|
Reduced Charges may apply for non complex Product depending upon parameters not applicable |
27(Provision for earthing) |
- |
5000 |
|
Reduced Charges may apply for non complex Product depending upon parameters not applicable |
26(Terminals for external conductors) |
- |
5000 |
|
Reduced Charges may apply for non complex Product depending upon parameters not applicable |
25(Supply connection and external flexible cords) |
- |
5000 |
|
Reduced Charges may apply for non complex Product depending upon parameters not applicable |
24(Components) |
- |
5000 |
|
Reduced Charges may apply for non complex Product depending upon parameters not applicable |
23(Internal wiring) |
- |
5000 |
|
Reduced Charges may apply for non complex Product depending upon parameters not applicable |
22(Construction) |
- |
85000 |
|
Reduced Charges may apply for non complex Product depending upon parameters not applicable |
20(Stability and mechanical hazards) |
- |
5000 |
|
Reduced Charges may apply for non complex Product depending upon parameters not applicable |
19(Abnormal Operation) |
- |
10000 |
|
Reduced Charges may apply for non complex Product depending upon parameters not applicable |
17(Over Load Protection of Transformers and associated circuits) |
- |
5000 |
|
Reduced Charges may apply for non complex Product depending upon parameters not applicable |
16.3(Electric Strength (after clause 15 and 16.2)) |
- |
5000 |
|
Reduced Charges may apply for non complex Product depending upon parameters not applicable |
16.2(Leakage Current (after Clause 15)) |
- |
5000 |
|
Reduced Charges may apply for non complex Product depending upon parameters not applicable |
16.1(General) |
- |
5000 |
|
Reduced Charges may apply for non complex Product depending upon parameters not applicable |
15.3(Humidity Test) |
- |
5000 |
|
Reduced Charges may apply for non complex Product depending upon parameters not applicable |
15.2(Spillage Test) |
- |
5000 |
|
Reduced Charges may apply for non complex Product depending upon parameters not applicable |
15.1(Ingress Protection test other than IPX0 (IP test)) |
- |
5000 |
|
Reduced Charges may apply for non complex Product depending upon parameters not applicable |
15.0(Moisture resistance) |
- |
7000 |
|
Reduced Charges may apply for non complex Product depending upon parameters not applicable |
14(Transient Over Voltages) |
- |
7000 |
|
Reduced Charges may apply for non complex Product depending upon parameters not applicable |
13.3(Electric Strength at operating temperature) |
- |
5000 |
|
Reduced Charges may apply for non complex Product depending upon parameters not applicable |
13.2(Leakage current at operating temperature) |
- |
5000 |
|
Reduced Charges may apply for non complex Product depending upon parameters not applicable |
13(Leakage current and electric strength at operating temperature) |
- |
10000 |
|
Reduced Charges may apply for non complex Product depending upon parameters not applicable |
11.3(Heating) |
- |
5000 |
|
Reduced Charges may apply for non complex Product depending upon parameters not applicable |
11.2(General) |
- |
5000 |
|
Reduced Charges may apply for non complex Product depending upon parameters not applicable |
11.1(General) |
- |
5000 |
|
Reduced Charges may apply for non complex Product depending upon parameters not applicable |
10.2(Current input) |
- |
5000 |
|
Reduced Charges may apply for non complex Product depending upon parameters not applicable |
10.1(Power input) |
- |
5000 |
|
Reduced Charges may apply for non complex Product depending upon parameters not applicable |
8.1.4(Protection against live parts against protective impedance) |
- |
5000 |
|
Reduced Charges may apply for non complex Product depending upon parameters not applicable |
8.1.3(Protection against live parts in visible glowing heating elements) |
- |
5000 |
|
Reduced Charges may apply for non complex Product depending upon parameters not applicable |
8.1.2(Protection against live parts in openings) |
- |
5000 |
|
Reduced Charges may apply for non complex Product depending upon parameters not applicable |
8.1.1(Protection against live parts in all positions) |
- |
5000 |
|
Reduced Charges may apply for non complex Product depending upon parameters not applicable |
7(Marking and instructions) |
- |
3000 |
|
Reduced Charges may apply for non complex Product depending upon parameters not applicable |
Annex C(Ageing test on motors) |
- |
5000 |
|
Reduced Charges may apply for non complex Product depending upon parameters not applicable |
15.2(Moisture resistance) |
- |
10000 |
|
Reduced Charges may apply for non complex Product depending upon parameters not applicable |
19.17(Abnormal operation) |
- |
10000 |
|
Reduced Charges may apply for non complex Product depending upon parameters not applicable |
20.1(Stability and mechanical hazards) |
- |
5000 |
|
Reduced Charges may apply for non complex Product depending upon parameters not applicable |
21.2(Mechanical strength) |
- |
5000 |
|
Reduced Charges may apply for non complex Product depending upon parameters not applicable |
21.3(Mechanical strength) |
- |
5000 |
|
Reduced Charges may apply for non complex Product depending upon parameters not applicable |
21(Mechanical Strength) |
- |
5000 |
|
Reduced Charges may apply for non complex Product depending upon parameters not applicable |
22.5(Construction) |
- |
5000 |
|
Reduced Charges may apply for non complex Product depending upon parameters not applicable |
22.6(Construction) |
- |
5000 |
|
Reduced Charges may apply for non complex Product depending upon parameters not applicable |
22.11(Construction) |
- |
5000 |
|
Reduced Charges may apply for non complex Product depending upon parameters not applicable |
22.16(Construction) |
- |
5000 |
|
Reduced Charges may apply for non complex Product depending upon parameters not applicable |
22.32(Construction) |
- |
5000 |
|
Reduced Charges may apply for non complex Product depending upon parameters not applicable |
22.42(Construction) |
- |
5000 |
|
Reduced Charges may apply for non complex Product depending upon parameters not applicable |
23.3(Internal wiring) |
- |
5000 |
|
Reduced Charges may apply for non complex Product depending upon parameters not applicable |
25(Supply connection and external flexible cords) |
- |
5000 |
|
Reduced Charges may apply for non complex Product depending upon parameters not applicable |
25.7(Supply connection and external flexible cords) |
- |
5000 |
|
Reduced Charges may apply for non complex Product depending upon parameters not applicable |
25.14(Supply connection and external flexible cords) |
- |
5000 |
|
Reduced Charges may apply for non complex Product depending upon parameters not applicable |
25.15(Supply connection and external flexible cords) |
- |
5000 |
|
Reduced Charges may apply for non complex Product depending upon parameters not applicable |
26.5(Terminals for external conductors) |
- |
5000 |
|
Reduced Charges may apply for non complex Product depending upon parameters not applicable |
27.5(Provision for earthing) |
- |
5000 |
|
Reduced Charges may apply for non complex Product depending upon parameters not applicable |
28.1(Screws and connections) |
- |
5000 |
|
Reduced Charges may apply for non complex Product depending upon parameters not applicable |
B.22.1(Construction) |
- |
5000 |
|
Reduced Charges may apply for non complex Product depending upon parameters not applicable |
B.22.3(Construction) |
- |
5000 |
|
Reduced Charges may apply for non complex Product depending upon parameters not applicable |
B.22.4(Construction) |
- |
5000 |
|
Reduced Charges may apply for non complex Product depending upon parameters not applicable |
B.22.5(Construction) |
- |
5000 |
|
Reduced Charges may apply for non complex Product depending upon parameters not applicable |
18(Endurance) |
- |
50000 |
|
Reduced Charges may apply for non complex Product depending upon parameters not applicable |
6(Classification) |
- |
5000 |
|
Reduced Charges may apply for non complex Product depending upon parameters not applicable |
5(General conditions for the tests) |
- |
5000 |
|
Reduced Charges may apply for non complex Product depending upon parameters not applicable |
4(General requirement) |
- |
5000 |
|
Reduced Charges may apply for non complex Product depending upon parameters not applicable |
9(Starting of motor operation test requirements and tests) |
- |
10000 |
|
Reduced Charges may apply for non complex Product depending upon parameters not applicable |
Annex D(Thermal motor protectors) |
- |
5000 |
|
Reduced Charges may apply for non complex Product depending upon parameters not applicable |
32(Radiation Toxicity and Similar Hazards) |
- |
5000 |
|
Reduced Charges may apply for non complex Product depending upon parameters not applicable |
A.2(Earth continuity test) |
- |
15000 |
|
Reduced Charges may apply for non complex Product depending upon parameters not applicable |
18(Endurance) |
- |
50000 |
|
Reduced Charges may apply for non complex Product depending upon parameters not applicable |
16.0(General) |
- |
5000 |
|
Reduced Charges may apply for non complex Product depending upon parameters not applicable |
|
05 Apr, 2027 |
- - |
809 |
EAMP Laboratories LLP, Palghar
| 7171526
| IS 10322 : PART 5 : SEC 3 (2012) |
Luminaires: Part 5 particular requirements: Sec 3 luminaires for road and street lighting (First Revision) |
- |
30000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
4(General Test Requireements) |
- |
1000 |
|
- |
5(Classification of Luminaires') |
- |
1000 |
|
- |
6.0(Marking) |
- |
500 |
|
- |
7.0(Construction) |
- |
2000 |
|
- |
8.0(Creepage Distance and Clearances) |
- |
1500 |
|
- |
9.0(Provision for earthing) |
- |
1500 |
|
- |
10.0(Terminals) |
- |
2000 |
|
- |
11.0(External & Internal Wiring) |
- |
2000 |
|
- |
12.0(Protection against electric shock) |
- |
1500 |
|
- |
13.0(Endurance Tests and Thermal Tests) |
- |
4000 |
|
- |
14.0(Resistance to Dust & Moisture) |
- |
4000 |
|
- |
15.0(Insulation Resistance and Electric Strength) |
- |
3000 |
|
- |
16.0(Resistance to Heat , fire and tracking) |
- |
2000 |
|
- |
17.0(Photometric Test) |
- |
4000 |
|
- |
|
13 Sep, 2025 |
- - |
810 |
EAMP Laboratories LLP, Palghar
| 7171526
| IS 10322 : Part 5 : Sec 5 (2013) |
Luminaires: Part 5 particular requirements: Sec 5 floodlights (First Revision) |
- |
30000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
4(General Test Requireements) |
- |
500 |
|
- |
5(Classification of Luminaires') |
- |
1000 |
|
- |
6.0(Marking) |
- |
1000 |
|
- |
7.0(Construction) |
- |
1500 |
|
- |
8.0(Creepage Distance and Clearances) |
- |
1500 |
|
- |
9.0(Provision for earthing) |
- |
1500 |
|
- |
10.0(Terminals) |
- |
1000 |
|
- |
11.0(External & Internal Wiring) |
- |
1500 |
|
- |
12.0(Protection against electric shock) |
- |
1500 |
|
- |
13.0(Endurance Tests and Thermal Tests) |
- |
5000 |
|
- |
14.0(Resistance to Dust & Moisture) |
- |
11000 |
|
- |
15.0(Insulation Resistance and Electric Strength) |
- |
5000 |
|
- |
16.0(Resistance to Heat , fire and tracking) |
- |
3000 |
|
- |
17.0(Photometric Test) |
- |
15000 |
|
- |
|
13 Sep, 2025 |
- - |