| 781 |
National Test House (WR) - NTH, Mumbai
| 7107604
| IS 3854 (2023) |
Switches for Domestic and Similar Purposes - Specification (Third Revision) |
- |
13000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl-4(General Requirements) |
- |
500 |
|
- |
| Cl-5(General notes on tests) |
- |
500 |
|
- |
| Cl-6(Rating) |
- |
500 |
|
- |
| Cl-7(Classification) |
- |
500 |
|
- |
| Cl-8(Marking) |
- |
500 |
|
- |
| Cl-9(Checking of dimensions) |
- |
500 |
|
- |
| Cl-10.1, 10.2(Prevention of Access to Live Parts) |
- |
500 |
|
- |
| Cl-10.3(Requirements for Accessible Metal Parts) |
- |
500 |
|
- |
| Cl-10.4(Requirements for Insulation of the Mechanism) |
- |
500 |
|
- |
| Cl. 10.5(Requirements for Insulation of the Mechanism with Respect to the Surrounding Environment) |
- |
5000 |
|
- |
| Cl-10.6(Requirements for Switches Operated Indirectly) |
- |
500 |
|
- |
| Cl-10.7(Requirements for Switches with Replaceable Pull Cord) |
- |
500 |
|
- |
| Cl-11(Provision for earthing) |
- |
500 |
|
- |
| Cl-12(Terminals) |
- |
1000 |
|
- |
| Cl-13(Constructional requirements) |
- |
500 |
|
- |
| Cl-14(Mechanism) |
- |
1000 |
|
- |
| Cl-15.1(Resistance to Ageing) |
- |
1500 |
|
- |
| Cl-15.2(Protection Provided by Enclosures of Switches) |
- |
500 |
|
- |
| Cl-15.3(Resistance to Humidity) |
- |
1500 |
|
- |
| Cl-16.1(General) |
- |
500 |
|
- |
| Cl-16.2(Test for Measuring the Insulation Resistance) |
- |
500 |
|
- |
| Cl-16.3(Electric Strength Test) |
- |
1000 |
|
- |
| Cl-17(Temperature rise) |
- |
1000 |
|
- |
| Cl-18(Making and breaking capacity) |
- |
500 |
|
- |
| Cl-19(Normal operation) |
- |
2500 |
|
- |
| Cl-20(Mechanical strength) |
- |
500 |
|
- |
| Cl-21(Resistance to heat) |
- |
1000 |
|
- |
| Cl-22(Screws, current carrying parts and connections) |
- |
500 |
|
- |
| Cl-23(Creepage distances, clearances and distance through sealing compound) |
- |
500 |
|
- |
| Cl-24.1(Resistance to abnormal heat and fire) |
- |
1000 |
|
- |
| Cl-24.2(Resistance to tracking) |
- |
500 |
|
- |
| Cl-25(Resistance to rusting) |
- |
500 |
|
- |
| 19.1(Test for Switches Intended for Inductive Loads) |
- |
1000 |
|
- |
| 19.2(Test for Switches Intended for Externally Ballasted Lamp Loads) |
- |
2500 |
|
- |
| 19.3(Test for Switches Intended for Self-ballasted Lamp Loads) |
- |
2500 |
|
- |
| 13.5(Attachment of knobs) |
- |
1000 |
|
- |
| 12.3.11(Table 11)(Test Current for the Verification of Electrical and Thermal Stresses in Normal Use of Screwless Terminals) |
- |
1000 |
|
- |
| 12.3.12(Table 13)(Deflection Test Forces) |
- |
500 |
|
- |
|
24 Jul, 2025 |
- - |
| 782 |
National Test House (WR) - NTH, Mumbai
| 7107604
| IS 3854 (1997) |
Switches for domestic and similar purposes - Specification (Second Revision) |
- |
9000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 6(Ratings) |
- |
0 |
|
- |
| 6.1(Ratings) |
- |
0 |
|
- |
| 6.2(Ratings) |
- |
0 |
|
- |
| 7(Classification) |
- |
0 |
|
- |
| 7.1(Classification) |
- |
0 |
|
- |
| 7.1.1(Classification) |
- |
0 |
|
- |
| 7.1.2(Classification) |
- |
0 |
|
- |
| 7.1.3(Classification) |
- |
0 |
|
- |
| 7.1.4(Classification) |
- |
0 |
|
- |
| 7.1.5(Classification) |
- |
0 |
|
- |
| 7.1.6(Classification) |
- |
0 |
|
- |
| 7.1.7(Classification) |
- |
0 |
|
- |
| 7.1.8(Classification) |
- |
0 |
|
- |
| 7.2(Classification) |
- |
0 |
|
- |
| 8(Marking) |
- |
0 |
|
- |
| 8.1(Marking) |
- |
0 |
|
- |
| 8.2(Marking) |
- |
0 |
|
- |
| 8.3(Marking) |
- |
0 |
|
- |
| 8.4(Marking) |
- |
0 |
|
- |
| 8.5(Marking) |
- |
0 |
|
- |
| 8.6(Marking) |
- |
0 |
|
- |
| 8.7(Marking) |
- |
0 |
|
- |
| 8.8(Marking) |
- |
0 |
|
- |
| 8.9(Marking) |
- |
0 |
|
- |
| 10(Protection against Electric Shock) |
- |
0 |
|
- |
| 10.1(Protection against electric shock
) |
- |
0 |
|
- |
| 10.2(Protection against electric shock
) |
- |
0 |
|
- |
| 10.3(Protection against electric shock
) |
- |
0 |
|
- |
| 10.3.1(Protection against electric shock
) |
- |
0 |
|
- |
| 10.3.2(Protection against electric shock
) |
- |
0 |
|
- |
| 10.4(Protection against electric shock
) |
- |
0 |
|
- |
| 10.5(Protection against electric shock
) |
- |
0 |
|
- |
| 10.6(Protection against electric shock
) |
- |
0 |
|
- |
| 10.7(Protection against electric shock
) |
- |
0 |
|
- |
| 11.1(Provision for earthing) |
- |
0 |
|
- |
| 11.2(Provision for earthing) |
- |
0 |
|
- |
| 11.3(Provision for earthing) |
- |
0 |
|
- |
| 11.4(Provision for earthing) |
- |
0 |
|
- |
| 12(Terminals) |
- |
0 |
|
- |
| 12.1(Terminals) |
- |
0 |
|
- |
| 12.2(Terminals) |
- |
0 |
|
- |
| 12.2.1(Terminals) |
- |
0 |
|
- |
| 12.2.2(Connection of conductor) |
- |
0 |
|
- |
| 12.2.3(Mechanical strength of terminals) |
- |
0 |
|
- |
| 12.2.4(Resistance to corrosion) |
- |
0 |
|
- |
| 12.2.5(Undue damage to conductor) |
- |
0 |
|
- |
| 12.2.6(Terminals) |
- |
0 |
|
- |
| 12.2.7(Insertion of conductor) |
- |
0 |
|
- |
| 12.2.8(Terminals) |
- |
0 |
|
- |
| 12.2.9(Locking against accidental loosening) |
- |
0 |
|
- |
| 12.2.10(Terminals) |
- |
0 |
|
- |
| 12.2.11(Distance between screw and conductor) |
- |
0 |
|
- |
| 12.2.12(Terminals) |
- |
0 |
|
- |
| 12.3(Terminals) |
- |
0 |
|
- |
| 12.3.1(Terminals) |
- |
0 |
|
- |
| 12.3.2(Screwless terminals) |
- |
0 |
|
- |
| 12.3.3(Connectin of conductor) |
- |
0 |
|
- |
| 12.3.4(Material of terminals) |
- |
0 |
|
- |
| 12.3.5(Clamping) |
- |
0 |
|
- |
| 12.3.6(Connection) |
- |
0 |
|
- |
| 12.3.7(v) Interconnection of conductors [Cl. 12.3.7]) |
- |
0 |
|
- |
| 12.3.8(Screwless terminals design) |
- |
0 |
|
- |
| 12.3.9(Screwless terminal fixing) |
- |
0 |
|
- |
| 12.3.10(Terminals) |
- |
0 |
|
- |
| 12.3.11(vi) Electrical & Thermal Stresses [Cl 12.3.11]) |
- |
0 |
|
- |
| 12.3.12(vii) Deflection Stresses [Cl. 12.3.12]) |
- |
0 |
|
- |
| 13(Constructional
requirements
) |
- |
0 |
|
- |
| 13.1(a) Insulating lining, barriers and the like [Cl 13.1]) |
- |
0 |
|
- |
| 13.2(b) Construction of switch [Cl 13.2]) |
- |
0 |
|
- |
| 13.3(c) Covers,cover plates and actuating members [Cl 13.3]) |
- |
0 |
|
- |
| 13.4(d) Ordinary switches [Cl 13.4]) |
- |
0 |
|
- |
| 13.5(e) Rotary switches [Cl 13.5]) |
- |
0 |
|
- |
| 13.6(f) Screws and other means [Cl 13.6]) |
- |
0 |
|
- |
| 13.7(g) Combination of switches or switches and socket outlets [Cl 13.7]) |
- |
0 |
|
- |
| 13.8(h) Assessories combined with switches [Cl. 13.8]) |
- |
0 |
|
- |
| 13.9(j) Switches other than ordinary switches [Cl. 13.9]) |
- |
0 |
|
- |
| 13.1(k) Switches to be installed in a box [Cl. 13.10]) |
- |
0 |
|
- |
| 13.11(l) Surface type switches other than ordinary switch [Cl. 13.11]) |
- |
0 |
|
- |
| 13.12, 13.13, 13.14(m) Inlet opening [Cl. 13.12.13.13 & 13.14]) |
- |
0 |
|
- |
| 13.15(Constructional
requirements
) |
- |
0 |
|
- |
| 13.15.1(Constructional
requirements
) |
- |
0 |
|
- |
| 13.15.2(Constructional
requirements
) |
- |
0 |
|
- |
| 14(Mechanism [Cl. 14]) |
- |
0 |
|
- |
| 14.1(Mechanism) |
- |
0 |
|
- |
| 14.2(Mechanism) |
- |
0 |
|
- |
| 14.3(Mechanism) |
- |
0 |
|
- |
| 14.4(Mechanism) |
- |
0 |
|
- |
| 14.5(Mechanism) |
- |
0 |
|
- |
| 14.6(Mechanism) |
- |
0 |
|
- |
| 15(Resistance to ageing, to harmful ingress of water and to humidity
) |
- |
0 |
|
- |
| 15.1(Resistance to Ageing, to Harmful Ingress of water and to Humidity [Cl. 15]: Resistance to Ageing, [Cl. 15.1]) |
- |
0 |
|
- |
| 15.2(b)Resistance to Harmful ingress of water [Cl. 15.2]) |
- |
0 |
|
- |
| 15.3(Resistance to ageing, to harmful ingress of water and to humidity
) |
- |
0 |
|
- |
| 16(Insulation
resistance and electric strength
) |
- |
0 |
|
- |
| 16.1(Insulation resistance [Cl. 16.1]) |
- |
0 |
|
- |
| 16.2( Electric Strength [Cl. 16.2]) |
- |
0 |
|
- |
| 16.3(Flash test) |
- |
0 |
|
- |
| 17(Temperature- rise [Cl. 17]) |
- |
0 |
|
- |
| 18(Marking and breaking Capacity[Cl. 18]) |
- |
0 |
|
- |
| 18.1(Making and breaking capacity ) |
- |
0 |
|
- |
| 18.2(Making and breaking capacity ) |
- |
0 |
|
- |
| 19(Normal Operation [Cl. 19] a) General & Operation) |
- |
0 |
|
- |
| 19.1(Normal operation) |
- |
0 |
|
- |
| 19.2(Normal Operation (For AX type Switches) [Cl. 19.2]) |
- |
0 |
|
- |
| 20(Mechanical Strength Test [Cl. 20]) |
- |
0 |
|
- |
| 20.1(Mechanical Strength Test) |
- |
0 |
|
- |
| 20.2(Mechanical Strength Test) |
- |
0 |
|
- |
| 20.3(Mechanical Strength Test) |
- |
0 |
|
- |
| 20.4(Mechanical
strength
) |
- |
0 |
|
- |
| 20.4.1(Mechanical
strength
) |
- |
0 |
|
- |
| 20.4.2(Mechanical
strength
) |
- |
0 |
|
- |
| 20.5(Mechanical Strength Test) |
- |
0 |
|
- |
| 20.6(Mechanical Strength Test) |
- |
0 |
|
- |
| 20.7(Mechanical Strength Test) |
- |
0 |
|
- |
| 20.8(Mechanical Strength Test) |
- |
0 |
|
- |
| 20.9(Mechanical
strength
) |
- |
0 |
|
- |
| 21.1(Resistance to heat
) |
- |
0 |
|
- |
| 21.2(Resistance to Heat) |
- |
0 |
|
- |
| 21.3(Resistance to heat
) |
- |
0 |
|
- |
| 22(Screw, Current Carrying Part And Connection [Cl.22]) |
- |
0 |
|
- |
| 22.1(i) Screw & Nuts [Cl.22.1]) |
- |
0 |
|
- |
| 22.2(Measurement and manual test) |
- |
0 |
|
- |
| 22.3(iii) Electrical Connections [Cl.22.3]) |
- |
0 |
|
- |
| 22.4(ii) Screw & rivets [Cl . 22.4]) |
- |
0 |
|
- |
| 22.5(iv) Current carrying part [Cl.22.5]) |
- |
0 |
|
- |
| 22.6(Inspection and chemical analysis) |
- |
0 |
|
- |
| 22.7(Screws, current
carrying parts and connections
) |
- |
0 |
|
- |
| 23(Creepage distances, clearances and distance through sealing compound [Cl.23]) |
- |
0 |
|
- |
| 23.1(Creepage distances,
clearances & distance through
sealing compound
) |
- |
0 |
|
- |
| 23.2(Creepage distances, clearances and distance through sealing compound [Cl.23]) |
- |
0 |
|
- |
| 24(Resistance of insulating material to abnormal heat, to fire and to tracking
) |
- |
0 |
|
- |
| 24.1.1(Resistance to Abnormal Heat & Fire [Cl.24.1] [Glow Wire Test] [Cl.24.1.1]) |
- |
0 |
|
- |
| 24.2(Resistance to tracking [For Switch other than ordinary] [Cl.24.2]) |
- |
0 |
|
- |
| 25 of IS 3854 : 1997(Resistance to rusting) |
- |
0 |
|
- |
|
24 Jul, 2025 |
- - |
| 783 |
INDIAN TESTING LABORATORY PRIVATE LIMITED, GREATER NOIDA
| 8171306
| IS 17190 (2020) |
Grouts for Filling of Joints of Tiles and Stones - Specification |
- |
22000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 5-Table 1-(i)(Linear shrinkage, percent, Max) |
- |
3000 |
|
- |
| 5-Table 1-(ii)(Water absorption after 30 min, percent, Max) |
- |
3000 |
|
- |
| 5-Table 1-(iii)(Water absorption after 240 min, percent, Max (optional)) |
- |
3000 |
|
- |
| 5-Table 1-(iv)(Compressive strength, MPa, Min) |
- |
3000 |
|
- |
| 5-Table 1-(v)(Flexural strength, MPa, Min) |
- |
2000 |
|
- |
| 5-Table 1-(vi)(Abrasion resistance, percent, Max) |
- |
3000 |
|
- |
| 5-Table 1-(vii)(Chemical resistance (optional)) |
- |
2000 |
|
- |
| 5-Table 1-(viii)(Transverse deformation, mm, Min) |
- |
3000 |
|
- |
| 6(Packing) |
- |
500 |
|
- |
| 7(Marking) |
- |
500 |
|
- |
| 5-Table 1-(i)(Linear shrinkage, percent, Max) |
- |
0 |
|
- |
| 5-Table 1-(ii)(Water absorption after 30 min, percent, Max) |
- |
0 |
|
- |
| 5-Table 1-(iii)(Water absorption after 240 min, percent, Max (optional)) |
- |
0 |
|
- |
| 5-Table 1-(iv)(Compressive strength, MPa, Min) |
- |
0 |
|
- |
| 5-Table 1-(v)(Flexural strength, MPa, Min) |
- |
0 |
|
- |
| 5-Table 1-(vi)(Abrasion resistance, percent, Max) |
- |
0 |
|
- |
| 5-Table 1-(vii)(Chemical resistance (optional)) |
- |
0 |
|
- |
| 5-Table 1-(viii)(Transverse deformation, mm, Min) |
- |
0 |
|
- |
| 6(Packing) |
- |
0 |
|
- |
| 7(Marking) |
- |
0 |
|
- |
|
15 Aug, 2028 |
- Included w.e.f. 26.02.2026 |
| 784 |
Vimta labs Limited, Hyderabad
| 6102906
| IS 302 : Part 1 (2008) |
Safety of household and similar electrical appliances: Part 1 general requirements (Sixth Revision) |
- |
35000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 7(Marking and instructions) |
- |
500 |
|
- |
| 8.1.1(Protection against live parts in all positions) |
- |
1000 |
|
- |
| 8.1.2(Protection against live parts in openings) |
- |
0 |
|
- |
| 8.1.3(Protection against live parts in visible glowing heating elements) |
- |
0 |
|
- |
| 8.1.4(Protection against live parts against protective impedance) |
- |
0 |
|
- |
| 9(Starting of motor operation test requirements and tests) |
- |
0 |
|
- |
| 10.1(Power input) |
- |
500 |
|
- |
| 10.2(Current input) |
- |
500 |
|
- |
| 11.1(General) |
- |
0 |
|
- |
| 11.2(General) |
- |
500 |
|
- |
| 11.3(Heating) |
- |
500 |
|
- |
| 13.1(General) |
- |
1000 |
|
- |
| 13.2(Leakage current at operating temperature) |
- |
1500 |
|
- |
| 13.3(Electric Strength at operating temperature) |
- |
1000 |
|
- |
| 14(Transient Over Voltages) |
- |
3500 |
|
- |
| 15.0(General) |
- |
500 |
|
- |
| 15.1(Ingress Protection test other than IPX0 (IP test)) |
- |
1000 |
|
- |
| 15.2(Spillage Test) |
- |
1000 |
|
- |
| 15.3(Humidity Test) |
- |
1000 |
|
- |
| 16.0(General) |
- |
500 |
|
- |
| 16.1(General) |
- |
1000 |
|
- |
| 16.2(Leakage Current (after Clause 15)) |
- |
1000 |
|
- |
| 16.3(Electric Strength (after clause 15 and 16.2)) |
- |
1000 |
|
- |
| 17(Over Load Protection of Transformers and associated circuits) |
- |
2000 |
|
- |
| 18(Endurance Test requirements and tests) |
- |
0 |
|
- |
| 19(Abnormal Operation) |
- |
2000 |
|
- |
| 20(Stability test) |
- |
1000 |
|
- |
| 21(Mechanical Strength Test) |
- |
2000 |
|
- |
| 22(Construction verification related test) |
- |
500 |
|
- |
| 23(General) |
- |
500 |
|
- |
| 24(Components) |
- |
500 |
|
- |
| 25(Supply connection and external flexible cords) |
- |
500 |
|
- |
| 26(Terminals for external conductors) |
- |
500 |
|
- |
| 27(Provision for earthing) |
- |
1000 |
|
- |
| 28(Screw test and connections) |
- |
500 |
|
- |
| 29(clearance, creepage distances and solid insulation) |
- |
1000 |
|
- |
| 30.1(Ball pressure test) |
- |
1000 |
|
- |
| 30.2(Glow Wire Test) |
- |
1000 |
|
- |
| 30.2(Needle Flame Test) |
- |
1000 |
|
- |
| 31(Resistance to Rusting) |
- |
2000 |
|
- |
| 32(Radiation Toxicity and Similar Hazards) |
- |
0 |
|
- |
| 4(General requirement) |
- |
0 |
|
- |
| 16(Leakage current and electric strength) |
- |
0 |
|
- |
| 17(Overload protection of transformers and associated circuits) |
- |
0 |
|
- |
| 18(Endurance) |
- |
0 |
|
- |
| 8.1.5(Live parts of built-in appliances) |
- |
0 |
|
- |
| 11.4(Heating appliances) |
- |
0 |
|
- |
| 11.5(Motor-operated appliances) |
- |
0 |
|
- |
| 11.6(Combined appliances) |
- |
0 |
|
- |
| 11.7(Duration corresponding) |
- |
0 |
|
- |
| 11.8(Temperature rise) |
- |
0 |
|
- |
| 19.11.4.1(Electrostatic discharges) |
- |
0 |
|
- |
| 19.11.4.2(Radiated fields) |
- |
0 |
|
- |
| 19.11.4.3(Fast transient bursts) |
- |
0 |
|
- |
| 19.11.4.4(Surge immunity test) |
- |
0 |
|
- |
| 19.11.4.5(Immunity to conducted discharges) |
- |
0 |
|
- |
| 19.11.4.6(Class 3 Voltage dips and interruptions) |
- |
0 |
|
- |
| 19.11.4.7(Harmonics) |
- |
0 |
|
- |
| 4(General Requirement) |
- |
0 |
|
- |
| 5(General conditions for tests) |
- |
0 |
|
- |
| 6(Classification- IS 302-1) |
- |
500 |
|
- |
| 7.1(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.1(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.1(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.1(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.1(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.1(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.1(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.3(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.4(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.5(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.6(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.7(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.8(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.9(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.1O(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.11(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.12(Marking- IS 302-2-15) |
- |
0 |
|
- |
| 7.13(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.14(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.15(Marking- IS 302-1) |
- |
0 |
|
- |
| 8(Protection Against Electric Shock, IS 302-1) |
- |
0 |
|
- |
| 11(Heating, IS 302-1, Table -3) |
- |
0 |
|
- |
| 11(Heating, IS 302-1, Table -3) |
- |
0 |
|
- |
| 11(Heating, IS 302-1, Table -3) |
- |
0 |
|
- |
| 11(Heating, IS 302-1, Table -3) |
- |
0 |
|
- |
| 11(Heating, IS 302-1, Table -3) |
- |
0 |
|
- |
| 11(Heating, IS 302-1) |
- |
0 |
|
- |
|
31 Mar, 2028 |
- Cl. No. 19.11.4.2 (EMI EMC Test), 24 (Components) |
| 785 |
JBS TESTING SOLUTIONS PVT LTD (27), JALANDHAR
| 9164606
| IS 4621 (1975) |
Specification for indicating bolts for use in public baths and lavatories (First Revision) |
- |
15000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Clause 4(DIMENSIONS AND TOLERANCES) |
- |
2000 |
|
- |
| Clause 7(WORKMANSHIP AND FINISH) |
- |
2000 |
|
- |
| Clause 4.1(Dimension and
tolerance) |
- |
2000 |
|
- |
| Clause 5.2
Table 2(i)(Body, knob and
indicating spindle) |
- |
2000 |
|
- |
| Clause 5.2
Table 2(ii)(Indicating disc) |
- |
2000 |
|
- |
| Clause 5.2
Table 2(iii)(Gears) |
- |
2000 |
|
- |
| Clause 7(Workmanship and
finish) |
- |
2000 |
|
- |
| Clause 8(Marking) |
- |
400 |
|
- |
| Clause 9(Packing) |
- |
400 |
|
- |
| Cl-6(Manufacture) |
- |
200 |
|
- |
| 5.0 Table -2(Tensile strength) |
- |
4000 |
|
- |
| IS 1868, Cl 10.0(Sulphur Dioxide test) |
- |
4000 |
|
- |
| Cl .5 Table-2(Elongation) |
- |
4000 |
|
- |
| IS 1868, cl 14(Resistance to crazing deformation) |
- |
4000 |
|
- |
| IS 1868, cl. 16(Light Reflection Property) |
- |
4000 |
|
- |
| IS 1868, cl. 15.0(Fastness of light) |
- |
4000 |
|
- |
| IS 1868, cl. 17.0(Electrical Breakdown Potential) |
- |
4000 |
|
- |
| IS 1868, cl. 18(continuity of the Anodizing Coating) |
- |
4000 |
|
- |
| IS 1868, cl. 12.0(Corrosion Resistance) |
- |
4000 |
|
- |
| IS 1868, cl. 12(CASS Test) |
- |
4000 |
|
- |
| IS 1868, cl. 12(AAS Test) |
- |
4000 |
|
- |
| IS 1868, cl. 13.0(Abrasion Resistance) |
- |
4000 |
|
- |
| Cl-5.0, Table-2(Tensile Strength) |
- |
4000 |
|
- |
| Cl-5.0, Table-2(Elongation) |
- |
4000 |
|
- |
| IS:1868, Clause-10.0(Sulphur Dioxide Test) |
- |
4000 |
|
- |
| IS:1868, Clause-14.0(Resistance to crazing deformation) |
- |
4000 |
|
- |
| IS:1868, Clause-16.0(Light reflection property) |
- |
4000 |
|
- |
| IS:1868, Clause-15.0(Fastness to light) |
- |
4000 |
|
- |
| IS:1868, Clause-15.0(Fastness to light) |
- |
4000 |
|
- |
| IS:1868, Clause-17.0(Electrical Breakdown Potential) |
- |
4000 |
|
- |
| IS:1868, Clause-18.0(Continuity of the Anodizing Coating) |
- |
4000 |
|
- |
| IS:1868, Clause-12.0(Corrosion Resistance) |
- |
4000 |
|
- |
| IS:1868, Clause-12.0(CASS Test) |
- |
4000 |
|
- |
| IS:1868, Clause-12.0(AAS Test) |
- |
4000 |
|
- |
| IS:1868, Clause-13.0(Abrasion Resistance) |
- |
4000 |
|
- |
|
- |
- included w.e.f 24.02.2026 |
| 786 |
Vimta labs Limited, Hyderabad
| 6102906
| IS 1475 (2024) |
Drinking Water Coolers - Specification (Fourth Revision) |
- |
45000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4(Classification) |
- |
500 |
|
- |
| 5(Construction) |
- |
500 |
|
- |
| 6.3(Cooling Capacity Test) |
- |
10000 |
|
- |
| 6.4(Maximum Operating Condition Test) |
- |
1000 |
|
- |
| 6.5(Pull Down Test) |
- |
1000 |
|
- |
| 9(Maximum Power Consumption Test) |
- |
2000 |
|
- |
| 10(Annual Energy Consumption Test) |
- |
15000 |
|
- |
| 11(Storage Capacity Test) |
- |
1000 |
|
- |
| 13(Functional Test) |
- |
1000 |
|
- |
| 14 a)(Protection against electric shock) |
- |
2000 |
|
- |
| 14 b)(High voltage (electric strength) test) |
- |
5000 |
|
- |
| 14 c)(Leakage current tests) |
- |
3000 |
|
- |
| 14 d)(Provision for earthing) |
- |
3000 |
|
- |
|
31 Mar, 2028 |
- included w.e.f 16.02.2026 |
| 787 |
Arihant Analytical Laboratory Pvt. Ltd., Sonipat
| 9167906
| IS 21 (2025) |
Wrought Aluminium and Aluminium Alloys for Manufacture of Utensils - Specification (Fifth Revision) |
All Type |
8000.00 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl-4(General requirements) |
- |
8000.00 |
|
- |
| Cl-5.1(Material) |
- |
8000.00 |
|
- |
| Cl-5.2(Chemical composition and mechanical properties of grades in Cl 5.1) |
- |
8000.00 |
|
- |
| Cl-5.3.1 a("Wrought Aluminium (with Minimum
99 Percent Al Content)- Iron+ Silicon") |
- |
8000.00 |
|
- |
| Cl-5.3.1 b("Wrought Aluminium (with Minimum
99 Percent Al Content)- Chromium") |
- |
8000.00 |
|
- |
| Cl-5.3.1 b("Wrought Aluminium (with Minimum
99 Percent Al Content)- Magnesium") |
- |
8000.00 |
|
- |
| Cl-5.3.1 b("Wrought Aluminium (with Minimum
99 Percent Al Content)- Manganese") |
- |
8000.00 |
|
- |
| Cl-5.3.1 b("Wrought Aluminium (with Minimum
99 Percent Al Content)- Nickel") |
- |
8000.00 |
|
- |
| Cl-5.3.1 b("Wrought Aluminium (with Minimum
99 Percent Al Content)- Zinc") |
- |
8000.00 |
|
- |
| Cl-5.3.1 b("Wrought Aluminium (with Minimum
99 Percent Al Content)- Titanium") |
- |
8000.00 |
|
- |
| Cl-5.3.1 b("Wrought Aluminium (with Minimum
99 Percent Al Content)- Tin") |
- |
8000.00 |
|
- |
| Cl-5.3.1 c("Wrought Aluminium (with Minimum
99 Percent Al Content)- Copper") |
- |
8000.00 |
|
- |
| Cl-5.3.1 Note 1("Wrought Aluminium (with Minimum
99 Percent Al Content)- Aluminium") |
- |
8000.00 |
|
- |
| Cl-5.3.1 d("Wrought Aluminium (with Minimum
99 Percent Al Content)- Others") |
- |
8000.00 |
|
- |
| Cl-5.3.2, Table-1 (i)(Wrought Aluminium Alloys-Silicon) |
- |
8000.00 |
|
- |
| Cl-5.3.2, Table-1 (ii)(Wrought Aluminium Alloys-Iron) |
- |
8000.00 |
|
- |
| Cl-5.3.2, Table-1 (iii)(Wrought Aluminium Alloys-Copper) |
- |
8000.00 |
|
- |
| Cl-5.3.2, Table-1 (iv)(Wrought Aluminium Alloys-Manganese) |
- |
8000.00 |
|
- |
| Cl-5.3.2, Table-1 (v)(Wrought Aluminium Alloys-Magnesium) |
- |
8000.00 |
|
- |
| Cl-5.3.2, Table-1 (vi)(Wrought Aluminium Alloys-Chromium) |
- |
8000.00 |
|
- |
| Cl-5.3.2, Table-1 (vii)(Wrought Aluminium Alloys-Nickel) |
- |
8000.00 |
|
- |
| Cl-5.3.2, Table-1 (viii)(Wrought Aluminium Alloys-Zinc) |
- |
8000.00 |
|
- |
| Cl-5.3.2, Table-1 (ix)(Wrought Aluminium Alloys -Zirconium) |
- |
8000.00 |
|
- |
| Cl-5.3.2, Table-1 (x)(Wrought Aluminium Alloys - Titanium) |
- |
8000.00 |
|
- |
| Cl-5.3.2, Table-1 (Note 3)(Wrought Aluminium Alloys- Aluminium) |
- |
8000.00 |
|
- |
| Cl-5.3.2, Table-1 (xi)(Wrought Aluminium Alloys- Others) |
- |
8000.00 |
|
- |
| Cl 5.4(Lead) |
- |
8000.00 |
|
- |
| Cl 5.4(Cadmium) |
- |
8000.00 |
|
- |
| Cl 5.4(Arsenic) |
- |
8000.00 |
|
- |
| Cl-7(Dimension) |
- |
8000.00 |
|
- |
| Cl-8(EARING TEST (OPTIONAL TEST)) |
- |
8000.00 |
|
- |
| Cl-5.2, (Cl-8,Table 2 of IS 737)(0.2% Proof Stress) |
- |
8000.00 |
|
- |
| Cl-5.2, (Cl-8,Table 2 of IS 737)(Tensile Strength) |
- |
8000.00 |
|
- |
| Cl-5.2, (Cl-8,Table 2 of IS 737)(Elongation) |
- |
8000.00 |
|
- |
| Cl-5.2, (Cl-8,Table 2 of IS 737)(Bend Test) |
- |
8000.00 |
|
- |
|
02 Jun, 2027 |
- Included w.e.f. 17.03.2026 |
| 788 |
Samridhi Test House Pvt. Ltd.
| 8184706
| IS 447 (1988) |
Specification for rubber hose for welding (Fourth Revision) |
All Grade / Type / Size / Designation |
5800 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl. 3.2 - Table 1(Bore size) |
- |
100 |
|
- |
| Cl. 3.2 - Table 1(Lining Thickness) |
- |
100 |
|
- |
| Cl. 3.2 - Table 1(Cover Thickness) |
- |
100 |
|
- |
| Cl. 3.2 - Table 1(Length %) |
- |
200 |
|
- |
| Cl. 3.3 - Table 2(Tensile strength - Lining MPA) |
- |
500 |
|
- |
| Cl. 3.3 - Table 2(Tensile strength - Cover Mpa) |
- |
500 |
|
- |
| Cl. 3.3 - Table 2(Elongation at break - Lining %) |
- |
500 |
|
- |
| Cl. 3.3 - Table 2(Elongation at break - Cover %) |
- |
500 |
|
- |
| Cl. 3.3 - Table 2(After Ageing Tensile strength - Lining %) |
- |
500 |
|
- |
| Cl. 3.3 - Table 2(After Ageing Tensile strength - Cover %) |
- |
500 |
|
- |
| Cl. 3.3 - Table 2(After Ageing Elongation at break - Lining %) |
- |
500 |
|
- |
| Cl. 3.3 - Table 2(After Ageing Elongation at break - Cover %) |
- |
500 |
|
- |
| Cl. 3.4 - Table3(Pressure Tests) |
- |
500 |
|
- |
| Cl. 3.4 - Table3(Adhesion KN/m Min) |
- |
500 |
|
- |
| Cl. 3.2 - Table 1(Bore size, mm) |
- |
0 |
|
- |
| Cl. 3.2 - Table 1(Lining Thickness, mm) |
- |
0 |
|
- |
| Cl. 3.2 - Table 1(Cover Thickness, mm) |
- |
0 |
|
- |
| Cl. 3.2 - Table 1(Length) |
- |
0 |
|
- |
| Cl. 3.3 - Table 2(Tensile strength - Lining, Mpa) |
- |
0 |
|
- |
| Cl. 3.3 - Table 2(Tensile strength - Cover, Mpa) |
- |
0 |
|
- |
| Cl. 3.3 - Table 2(Elongation at break - Lining) |
- |
0 |
|
- |
| Cl. 3.3 - Table 2(Elongation at break - Cover) |
- |
0 |
|
- |
| Cl. 3.3 - Table 2(After Ageing Tensile strength - Lining) |
- |
0 |
|
- |
| Cl. 3.3 - Table 2(After Ageing Tensile strength - Cover) |
- |
0 |
|
- |
| Cl. 3.3 - Table 2(After Ageing Elongation at break - Lining) |
- |
0 |
|
- |
| Cl. 3.3 - Table 2(After Ageing Elongation at break - Cover) |
- |
0 |
|
- |
| Cl. 3.4 - Table3(Pressure Tests) |
- |
0 |
|
- |
| Cl. 3.4 - Table3(Adhesion, KN/m Min) |
- |
0 |
|
- |
| Cl. 3.4 - Table3(Adhesion) |
- |
0 |
|
- |
| Cl. 3.4 - Table3(Pressure Tests) |
- |
0 |
|
- |
| Cl. 3.3 - Table 2(After Ageing Elongation at break - Cover) |
- |
0 |
|
- |
| Cl. 3.3 - Table 2(After Ageing Elongation at break - Lining) |
- |
0 |
|
- |
| Cl. 3.3 - Table 2(After Ageing Tensile strength - Cover) |
- |
0 |
|
- |
| Cl. 3.3 - Table 2(After Ageing Tensile strength - Lining) |
- |
0 |
|
- |
| Cl. 3.3 - Table 2(Elongation at break - Cover) |
- |
0 |
|
- |
| Cl. 3.3 - Table 2(Elongation at break - Lining) |
- |
0 |
|
- |
| Cl. 3.3 - Table 2(Tensile strength - Cover) |
- |
0 |
|
- |
| Cl. 3.3 - Table 2(Tensile strength - Lining) |
- |
0 |
|
- |
| Cl. 3.2 - Table 1(Length) |
- |
0 |
|
- |
| Cl. 3.2 - Table 1(Cover Thickness) |
- |
0 |
|
- |
| Cl. 3.2 - Table 1(Lining Thickness) |
- |
0 |
|
- |
| Cl. 3.2 - Table 1(Bore size) |
- |
0 |
|
- |
| Cl. 3.2 - Table 1(Bore size) |
- |
0 |
|
- |
| Cl. 3.2 - Table 1(Lining Thickness) |
- |
0 |
|
- |
| Cl. 3.2 - Table 1(Cover Thickness) |
- |
0 |
|
- |
| Cl. 3.2 - Table 1(Length %) |
- |
0 |
|
- |
| Cl. 3.3 - Table 2(Tensile strength - Lining MPA) |
- |
0 |
|
- |
| Cl. 3.3 - Table 2(Tensile strength - Cover Mpa) |
- |
0 |
|
- |
| Cl. 3.3 - Table 2(Elongation at break - Lining %) |
- |
0 |
|
- |
| Cl. 3.3 - Table 2(Elongation at break - Cover %) |
- |
0 |
|
- |
| Cl. 3.3 - Table 2(After Ageing Tensile strength - Lining %) |
- |
0 |
|
- |
| Cl. 3.3 - Table 2(After Ageing Tensile strength - Cover %) |
- |
0 |
|
- |
| Cl. 3.3 - Table 2(After Ageing Elongation at break - Lining %) |
- |
0 |
|
- |
| Cl. 3.3 - Table 2(After Ageing Elongation at break - Cover %) |
- |
0 |
|
- |
| Cl. 3.4 - Table3(Pressure Tests) |
- |
0 |
|
- |
| Cl. 3.4 - Table3(Adhesion KN/m Min) |
- |
0 |
|
- |
| Cl. 3.2 - Table 1(Bore size, mm) |
- |
0 |
|
- |
| Cl. 3.2 - Table 1(Lining Thickness, mm) |
- |
0 |
|
- |
| Cl. 3.2 - Table 1(Cover Thickness, mm) |
- |
0 |
|
- |
| Cl. 3.2 - Table 1(Length) |
- |
0 |
|
- |
| Cl. 3.3 - Table 2(Tensile strength - Lining, Mpa) |
- |
0 |
|
- |
| Cl. 3.3 - Table 2(Tensile strength - Cover, Mpa) |
- |
0 |
|
- |
| Cl. 3.3 - Table 2(Elongation at break - Lining) |
- |
0 |
|
- |
| Cl. 3.3 - Table 2(Elongation at break - Cover) |
- |
0 |
|
- |
| Cl. 3.3 - Table 2(After Ageing Tensile strength - Lining) |
- |
0 |
|
- |
| Cl. 3.3 - Table 2(After Ageing Tensile strength - Cover) |
- |
0 |
|
- |
| Cl. 3.3 - Table 2(After Ageing Elongation at break - Lining) |
- |
0 |
|
- |
| Cl. 3.3 - Table 2(After Ageing Elongation at break - Cover) |
- |
0 |
|
- |
| Cl. 3.4 - Table3(Pressure Tests) |
- |
0 |
|
- |
| Cl. 3.4 - Table3(Adhesion, KN/m Min) |
- |
0 |
|
- |
| Cl. 3.4 - Table3(Adhesion) |
- |
0 |
|
- |
| Cl. 3.4 - Table3(Pressure Tests) |
- |
0 |
|
- |
| Cl. 3.3 - Table 2(After Ageing Elongation at break - Cover) |
- |
0 |
|
- |
| Cl. 3.3 - Table 2(After Ageing Elongation at break - Lining) |
- |
0 |
|
- |
| Cl. 3.3 - Table 2(After Ageing Tensile strength - Cover) |
- |
0 |
|
- |
| Cl. 3.3 - Table 2(After Ageing Tensile strength - Lining) |
- |
0 |
|
- |
| Cl. 3.3 - Table 2(Elongation at break - Cover) |
- |
0 |
|
- |
| Cl. 3.3 - Table 2(Elongation at break - Lining) |
- |
0 |
|
- |
| Cl. 3.3 - Table 2(Tensile strength - Cover) |
- |
0 |
|
- |
| Cl. 3.3 - Table 2(Tensile strength - Lining) |
- |
0 |
|
- |
| Cl. 3.2 - Table 1(Length) |
- |
0 |
|
- |
| Cl. 3.2 - Table 1(Cover Thickness) |
- |
0 |
|
- |
| Cl. 3.2 - Table 1(Lining Thickness) |
- |
0 |
|
- |
| Cl. 3.2 - Table 1(Bore size) |
- |
0 |
|
- |
|
- |
- included w.e.f 24.02.2026 |
| 789 |
Samridhi Test House Pvt. Ltd.
| 8184706
| IS 1475 (2024) |
Drinking Water Coolers - Specification (Fourth Revision) |
- |
39500 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4(Classification) |
- |
1000 |
|
- |
| 5(Construction) |
- |
1000 |
|
- |
| 6.3(Cooling Capacity Test) |
- |
5000 |
|
- |
| 6.4(Maximum Operating Condition Test) |
- |
5000 |
|
- |
| 6.5(Pull Down Test) |
- |
3500 |
|
- |
| 9(Maximum Power Consumption Test) |
- |
3000 |
|
- |
| 10(Annual Energy Consumption Test) |
- |
7000 |
|
- |
| 11(Storage Capacity Test) |
- |
5000 |
|
- |
| 13(Functional Test) |
- |
5000 |
|
- |
| 14 a)(Protection against electric shock) |
- |
1000 |
|
- |
| 14 b)(High voltage (electric strength) test) |
- |
1000 |
|
- |
| 14 c)(Leakage current tests) |
- |
1000 |
|
- |
| 14 d)(Provision for earthing) |
- |
1000 |
|
- |
|
- |
- - |
| 790 |
EKO PRO ENGINEERS PRIVATE LIMITED (32/37) GHAZIABAD
| 8164006
| IS 1489 (Part 1) (2015) |
Portland pozzolana cement - Specification: Part 1 fly Ash Based |
ALL |
3340 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 7 -Table 2- vi(Drying Shrinkage- IS 4031 Part 10) |
- |
3340 |
|
- |
| 7 -Table 2- v(Transverse Strength - IS 4031 Part 8 (Optional)) |
- |
0 |
|
- |
| 7 -Table 2- iv- c(Compressive Strength At 672 hrs ± 4 hr - IS 4031 Part 6) |
- |
3340 |
|
- |
| 7 -Table 2- iv- b(Compressive Strength At 168 hrs ± 2 hr - IS 4031 Part 6) |
- |
3340 |
|
- |
| 7 -Table 2- iv- a(Compressive Strength At 72 hrs ± 1 hr - IS 4031 Part 6) |
- |
3340 |
|
- |
| 7 -Table 2-iii- b(Setting Time Final- 4031 Part 5) |
- |
3340 |
|
- |
| 7 -Table 2- iii- a(Setting Time Initial- 4031 Part 5) |
- |
3340 |
|
- |
| 7 -Table 2- ii- b(Expansion after aeration- 4031 Part 3) |
- |
3340 |
|
- |
| 7 -Table 2- ii- b(Expansion by Autoclave- 4031 Part 3) |
- |
3340 |
|
- |
| 7 -Table 2- ii- a(Expansion after aeration - 4031 Part 3) |
- |
3340 |
|
- |
| 7 -Table 2- ii- a(Expansion by Le Chatelier- 4031 Part 3) |
- |
3340 |
|
- |
| 7 -Table 2- i(Fineness 4031 Part 2) |
- |
3340 |
|
- |
| 6 - Table - 1 vi( Alkali content as (Na2O + 0.658 K2O) - Cl 4.11 of IS 4032:1985) |
- |
3340 |
|
- |
| 6 - Table - 1 v(Chloride content - Cl 4.13 of IS 4032:1985) |
- |
3340 |
|
- |
| 6 - Table - 1 iv(Loss on ignition - Cl 7.1 of IS 4032:1985) |
- |
3340 |
|
- |
| 6 - Table - 1 iii(Total Sulphur Content calculated as Sulphuric Anhydride (SO3) - Cl 7.3 of IS 4032:1985) |
- |
3340 |
|
- |
| 6 - Table - 1 ii(Magnesia - Cl 7.2 of IS 4032:1985) |
- |
3340 |
|
- |
| 6 - Table - 1 i(Insoluble residue - Cl 7.4 of IS 4032:1985) |
- |
3340 |
|
- |
| 6 - Table - 1 vi( Alkali content as (Na2O + 0.658 K2O) - Cl 4.11 of IS 4032:1985) |
- |
3340 |
|
- |
| 6 - Table - 1 v(Chloride content - Cl 4.13 of IS 4032:1985) |
- |
3340 |
|
- |
| 6 - Table - 1 iv(Loss on ignition - Cl 7.1 of IS 4032:1985) |
- |
3340 |
|
- |
| 6 - Table - 1 iii(Total Sulphur Content calculated as Sulphuric Anhydride (SO3) - Cl 7.3 of IS 4032:1985) |
- |
3340 |
|
- |
| 6 - Table - 1 ii(Magnesia - Cl 7.2 of IS 4032:1985) |
- |
3340 |
|
- |
| 6 - Table - 1 i(Insoluble residue - Cl 7.4 of IS 4032:1985) |
- |
3340 |
|
- |
| 7 -Table 2- vi(Drying Shrinkage- IS 4031 Part 10) |
- |
3340 |
|
- |
| 7 -Table 2- v(Transverse Strength - IS 4031 Part 8 (Optional)) |
- |
0 |
|
- |
| 7 -Table 2- iv- c(Compressive Strength At 672 hrs ± 4 hr - IS 4031 Part 6) |
- |
3340 |
|
- |
| 7 -Table 2- iv- b(Compressive Strength At 168 hrs ± 2 hr - IS 4031 Part 6) |
- |
3340 |
|
- |
| 7 -Table 2- iv- a(Compressive Strength At 72 hrs ± 1 hr - IS 4031 Part 6) |
- |
3340 |
|
- |
| 7 -Table 2-iii- b(Setting Time Final- 4031 Part 5) |
- |
3340 |
|
- |
| 7 -Table 2- iii- a(Setting Time Initial- 4031 Part 5) |
- |
3340 |
|
- |
| 7 -Table 2- ii- b(Expansion after aeration- 4031 Part 3) |
- |
3340 |
|
- |
| 7 -Table 2- ii- b(Expansion by Autoclave- 4031 Part 3) |
- |
3340 |
|
- |
| 7 -Table 2- ii- a(Expansion after aeration - 4031 Part 3) |
- |
3340 |
|
- |
| 7 -Table 2- ii- a(Expansion by Le Chatelier- 4031 Part 3) |
- |
3340 |
|
- |
| 7 -Table 2- i(Fineness 4031 Part 2) |
- |
3340 |
|
- |
| 6 - Table - 1 vi( Alkali content as (Na2O + 0.658 K2O) - Cl 4.11 of IS 4032:1985) |
- |
3340 |
|
- |
| 6 - Table - 1 v(Chloride content - Cl 4.13 of IS 4032:1985) |
- |
3340 |
|
- |
| 6 - Table - 1 iv(Loss on ignition - Cl 7.1 of IS 4032:1985) |
- |
3340 |
|
- |
| 6 - Table - 1 iii(Total Sulphur Content calculated as Sulphuric Anhydride (SO3) - Cl 7.3 of IS 4032:1985) |
- |
3340 |
|
- |
| 6 - Table - 1 ii(Magnesia - Cl 7.2 of IS 4032:1985) |
- |
3340 |
|
- |
| 6 - Table - 1 i(Insoluble residue - Cl 7.4 of IS 4032:1985) |
- |
3340 |
|
- |
| 6 - Table - 1 vi( Alkali content as (Na2O + 0.658 K2O) - Cl 4.11 of IS 4032:1985) |
- |
3340 |
|
- |
| 6 - Table - 1 v(Chloride content - Cl 4.13 of IS 4032:1985) |
- |
3340 |
|
- |
| 6 - Table - 1 iv(Loss on ignition - Cl 7.1 of IS 4032:1985) |
- |
3340 |
|
- |
| 6 - Table - 1 iii(Total Sulphur Content calculated as Sulphuric Anhydride (SO3) - Cl 7.3 of IS 4032:1985) |
- |
3340 |
|
- |
| 6 - Table - 1 ii(Magnesia - Cl 7.2 of IS 4032:1985) |
- |
3340 |
|
- |
| 6 - Table - 1 i(Insoluble residue - Cl 7.4 of IS 4032:1985) |
- |
3340 |
|
- |
| Clause 7
Table 2 SI No. (v)
(Compressive strength of Transverse Specimen, 672 ± 4 h) |
- |
0 |
|
- |
| Clause 7
Table 2 SI No. (v)
(Compressive strength of Transverse Specimen, 168 ± 2 h) |
- |
0 |
|
- |
| Clause 7
Table 2 SI No. (v)
(Compressive strength of Transverse Specimen, 72 ± 1 h) |
- |
0 |
|
- |
| Clause 7
Table 2 SI No. (v)
(Transverse Strength, 672 ± 4 h) |
- |
0 |
|
- |
| Clause 7Table 2 SI No. (v)(Transverse Strength, 168 ± 2 h) |
- |
0 |
|
- |
| Clause 7Table 2 SI No. (v)(Transverse Strength, 72 ± 1 h) |
- |
0 |
|
- |
| 11(Marking) |
- |
3340 |
|
- |
| 4(RAW MATERIAL) |
- |
3340 |
|
- |
| 11(MARKING) |
- |
3340 |
|
- |
|
27 May, 2028 |
- - |
| 791 |
JBS TESTING SOLUTIONS PVT LTD (27), JALANDHAR
| 9164606
| IS 1328 (2025) |
Veneered Decorative Plywood - Specification ( Fourth Revision ) |
Type 1 & Type 2 |
10000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl 4.1(Grades) |
- |
10000 |
|
- |
|
- |
- - |
| 792 |
Vimta labs Limited, Hyderabad
| 6102906
| IS 302 : Part 2 : Sec 80 (2017) |
Household and similar electrical appliances - Safety: Part 2 - 80 particular requirements for fans (First Revision) |
- |
35000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 32.0(Radiation, Toxicity and Similar Hazards) |
- |
0 |
|
- |
| 31.0(Resistance To Rusting) |
- |
2000 |
|
- |
| 30.0(Resistance To Heat and Fire) |
- |
3000 |
|
- |
| 29.0(Creepage Distances and Clearances) |
- |
1000 |
|
- |
| 28.0(Screws and Connections) |
- |
500 |
|
- |
| 27.0(Provision For Earthing) |
- |
1000 |
|
- |
| 26.0(Terminals for external conductors) |
- |
500 |
|
- |
| 25.0(Supply Connection and External Flexible Cords) |
- |
500 |
|
- |
| 24.0(Components) |
- |
500 |
|
- |
| 23.0(Internal Wiring) |
- |
500 |
|
- |
| 22.0(Construction) |
- |
500 |
|
- |
| 21.0(Mechanical Strength) |
- |
2000 |
|
- |
| 20.0(Stability and mechanical hazards) |
- |
1000 |
|
- |
| 19.0(Abnormal Operation) |
- |
2000 |
|
- |
| 17.0(Overload Protection of transformer and associated circuit) |
- |
2000 |
|
- |
| 16.0(Leakage current and Electric strength (After Humidity (Environmental) Treatment)) |
- |
3500 |
|
- |
| 15.0(Moisture resistance) |
- |
3500 |
|
- |
| 14.0(Transient Overvoltage) |
- |
3500 |
|
- |
| 13.0(Leakage Current and electric strength at operating temperature) |
- |
3500 |
|
- |
| 11.0(Heating) |
- |
1000 |
|
- |
| 10.0(Input and Current) |
- |
1000 |
|
- |
| 8.0(Protection against access to live parts) |
- |
1000 |
|
- |
| 7.0(Classification) |
- |
500 |
|
- |
| 6.0(Marking and Instructions) |
- |
500 |
|
- |
| 19.11.4.1(Electrostatic discharges) |
- |
0 |
|
- |
| 19.11.4.2(Radiated fields) |
- |
0 |
|
- |
| 19.11.4.3(Fast transient bursts) |
- |
0 |
|
- |
| 19.11.4.4(Surge immunity test) |
- |
0 |
|
- |
| 19.11.4.5(Immunity to conducted discharges) |
- |
0 |
|
- |
| 19.11.4.6(Class 3 Voltage dips and interruptions) |
- |
0 |
|
- |
| 19.11.4.7(Harmonics) |
- |
0 |
|
- |
| 4(GENERAL REQUIREMENT) |
- |
0 |
|
- |
| 5(GENERAL CONDITIONS FOR THE TESTS) |
- |
0 |
|
- |
|
31 Mar, 2028 |
- 1 32.0 (Radiation, Toxicity and Similar Hazards) Radiation, Toxicity and Similar Hazards Testing facility not available. |
| 793 |
INDIAN TESTING LABORATORY PRIVATE LIMITED, GREATER NOIDA
| 8171306
| IS 5175 (2022) |
Fibre ropes - Polypropylene split film monofilament and multifilament PP 2 and polypropylene high tenacity multifilament PP 3 3- 4- 8- and 12- strand ropes (fourth revision) |
- |
7000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Clause 6, (Table 1,2,3)(Diameter) |
- |
500 |
|
- |
| Clause 6, (Table 1,2,3)(Linear Density) |
- |
1000 |
|
- |
| Clause 6, (Table 1,2,3)(Minimum Breaking Force) |
- |
1000 |
|
- |
| 5.2(Pitch or length of lay) |
- |
500 |
|
- |
| 5.1(type A: 3-strand hawser-laid rope) |
- |
500 |
|
- |
| 5.1(type B: 4-strand shroud-laid rope) |
- |
500 |
|
- |
| 5.1(type L: 8-strand braided rope) |
- |
500 |
|
- |
| 5.1(type T: 12-strand braided rope) |
- |
300 |
|
- |
| 4(Designation) |
- |
300 |
|
- |
| 5.1(General requirements) |
- |
300 |
|
- |
| 5.2, ISO 9554:2019 Cl. 7.1.3(Marking and labelling, for Ref no. equal or greater than 14 only.) |
- |
300 |
|
- |
| 5.2, ISO 9554:2019 Cl. 7.2(Labelling) |
- |
300 |
|
- |
| 6(Physical properties) |
- |
500 |
|
- |
| 6(Physical properties) |
- |
500 |
|
- |
| Clause 6, (Table 1,2,3)(Diameter) |
- |
0 |
|
- |
| Clause 6, (Table 1,2,3)(Linear Density) |
- |
0 |
|
- |
| Clause 6, (Table 1,2,3)(Minimum Breaking Force) |
- |
0 |
|
- |
| 5.2(Pitch or length of lay) |
- |
0 |
|
- |
| 5.1(type A: 3-strand hawser-laid rope) |
- |
0 |
|
- |
| 5.1(type B: 4-strand shroud-laid rope) |
- |
0 |
|
- |
| 5.1(type L: 8-strand braided rope) |
- |
0 |
|
- |
| 5.1(type T: 12-strand braided rope) |
- |
0 |
|
- |
| 4(Designation) |
- |
0 |
|
- |
| 5.1(General requirements) |
- |
0 |
|
- |
| 5.2, ISO 9554:2019 Cl. 7.1.3(Marking and labelling, for Ref no. equal or greater than 14 only.) |
- |
0 |
|
- |
| 5.2, ISO 9554:2019 Cl. 7.2(Labelling) |
- |
0 |
|
- |
| 6(Physical properties) |
- |
0 |
|
- |
| 6(Physical properties) |
- |
0 |
|
- |
|
15 Aug, 2028 |
- included w.e.f 17.03.2026 |
| 794 |
Vimta labs Limited, Hyderabad
| 6102906
| IS 16333 : Part 3 (2022) |
Mobile phone handsets: Part 3 Indian language support for mobile phone handsets - Specific requirements(Second Revision) |
- |
10000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 5.1(Inputting of text) |
- |
5000 |
|
- |
| 5.2(Message Readability) |
- |
5000 |
|
- |
| 6(Marking) |
- |
0 |
|
- |
| "Cl.6.1 "(Marking) |
- |
0 |
|
- |
| "Cl.6.2 "(BIS Certification Marking) |
- |
0 |
|
- |
| 4(Requirements) |
- |
0 |
|
- |
| 5(Tests) |
- |
0 |
|
- |
| 6(Marking) |
- |
0 |
|
- |
|
31 Mar, 2028 |
- included w.e.f 16.02.2026 |
| 795 |
Bombay Textiles Research Association (BTRA), Mumbai
| 7130206
| IS 15869 (2020) |
Textiles – Open weave coir Bhoovastra – Specification (first revision) |
OPEN WEAVE COIR BHOOVASTRA |
29100 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Clause 5, Table 1, (i)(Mass per unit area, g/m2, Min) |
- |
510 |
|
- |
| Clause 5, Table 1, (ii)(Width, cm, Min) |
- |
510 |
|
- |
| Clause 5, Table 1, (iii)(Length, m) |
- |
510 |
|
- |
| Clause 5, Table 1, (iv)(Thickness at 20 kPa, mm, Min) |
- |
510 |
|
- |
| Clause 5, Table 1, (v)(Runnage, m/kg) |
- |
1510 |
|
- |
| Clause 5, Table 1, (vi)(Break load, dry (kN/m), Min) |
- |
1500 |
|
- |
| Clause 5, Table 1, (vii)(Break load, wet (kN/m), Min) |
- |
1500 |
|
- |
| Clause 5, Table 1, (viii)(Peak load, dry (kN/m), Min) |
- |
1500 |
|
- |
| Clause 5, Table 1, (ix)(Peak load, wet (kN/m), Min) |
- |
1500 |
|
- |
| Clause 5, Table 1, (x)(Trapezoidal Tearing Strength at 25 mm Gauge Length) |
- |
2500 |
|
- |
| Clause 5, Table 1, (xi)(Mesh size, mm, Min) |
- |
1500 |
|
- |
| Clause 6.5, Table 2, (ii)(pH of aqueous extract) |
- |
510 |
|
- |
| Clause 6.5, Table 2, (iii)(Free and releasable formaldehyde (Max)) |
- |
2510 |
|
- |
| Clause 6.5, Table 2, (iv)(Extractable heavy metals by artificial acidic sweat (ppm) (Max)) |
- |
5010 |
|
- |
| Clause 6.5, Table 2, (v)(Pentachlorophenols (PCP), (ppm)) |
- |
3010 |
|
- |
| Clause 6.5, Table 2, (vi)(Banned aryl amines from azo dyes, (ppm)) |
- |
4510 |
|
- |
|
- |
- Included w.e.f. 17.02.2026
Exclusion: Clause 6.5, Table 2, (i) (Residual pesticides (sum parameter) (ppm)) |
| 796 |
LPG Equipment Research Centre (LERC), Bengaluru
| 6141034
| IS 17153 (2019) |
Domestic gas stoves for use with piped natural gas (PNG) - Specification |
- |
24000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 26(Burner-5) |
- |
5000 |
|
- |
| 26(Burner-4) |
- |
0 |
|
- |
| 26(Burner-3) |
- |
0 |
|
- |
| 26(Burner-2) |
- |
0 |
|
- |
| 26(Burner-1) |
- |
0 |
|
- |
| 25.2(With the Burner lighted on full on, the flame temperature at a height of H+20 mm) |
- |
1000 |
|
- |
| 25.1(Temperature of synthetic rubber diaphragm in gas carrying components) |
- |
3000 |
|
- |
| 25.1(Temperature of the surface in normal use) |
- |
0 |
|
- |
| 25.1(Temperature of the portion of the surface other than the working surface likely to be touched accidentally.) |
- |
0 |
|
- |
| 25.1(Rise of Temperature above room temperature in (Wall, Floor, Ceiling), after two hours of operation) |
- |
0 |
|
- |
| 24(Burner-5) |
- |
5000 |
|
- |
| 24(Burner-4) |
- |
0 |
|
- |
| 24(Burner-3) |
- |
0 |
|
- |
| 24(Burner-2) |
- |
0 |
|
- |
| 24(Burner-1) |
- |
0 |
|
- |
| 23(When operated at pressure 20-25 gf/cm2 , there shall be no extinction of flame on any of the burneroperating at the max of the burner, when the appliance is placed in normal current of air with velocity of 2 m/s.) |
- |
500 |
|
- |
| 22(When operated at pressure 20-25 gf/cm2 , for one at full on position, no soot shall be deposited on burner or on the bottom of the vessel.) |
- |
500 |
|
- |
| 21(When operated at pressure 20-25 gf/cm2 for half an hour flame shall be reduced to simmer and then brought back to full on, operation shall be repeated five times, no flash back shall occur during the test.) |
- |
500 |
|
- |
| 20(Ignition of Burner flame, their operation and turning off shall not give rise to undue excessive noise during the operation.) |
- |
500 |
|
- |
| 19.3(Fixed Min Pilot flame shall be sufficient to relight the main burner at the 21 mbar gas inlet pressure.) |
- |
0 |
|
- |
| 19.2(Pilot Flame shall be Stable without lifting or soot deposition at gas inlet pressure from 20-25 gf/cm2) |
- |
0 |
|
- |
| 19.1.1(When the gas consumption of the burner is reduced to simmer after operating half an hour on full ON flame shall not extinguish, blow off, strike back or form soot at 21 mbar gas inlet pressure.) |
- |
0 |
|
- |
| 19.1(It shall be possible to operate stove with taps fully open at gas inlet pressure , without the flame extinguishing, blowing off or striking back and without the formation of soot.) |
- |
0 |
|
- |
| 18.4.1(The flame failure device if provided shall confirm to IS:5116) |
- |
0 |
|
- |
| 18.3(When the burner is ignited from a pilot flame and/or by an electric/electronic method, the ignition and flame travel shall be smooth at pressure……..) |
- |
0 |
|
- |
| 18.2(if the flame is applied to any of the outer row of the burner ports when the gas is flowing , flame travel shall be complete……..) |
- |
0 |
|
- |
| 18.1(Where the burner or burners are lighted by automatic ignition (Battery of flint operated or by a pilot flame , it shall not be possible for gas to be admitted to the main burner without being smoothly ignited by the pilot flame. Each burner should be at room temperature at the begining of the test and should be tested in turn. ) |
- |
0 |
|
- |
| 18.1(There shall be easy and safe access of lighting each burner by matchstick and it shall be easy to see that the burner is lighted) |
- |
0 |
|
- |
| 17.3(When the gas consumption of the burner is reduced to simmer, the flame shall not extinguish, blow off, strike back or form soot, when tested with commercial PNG at 21 mbar gas inlet pressure.) |
- |
0 |
|
- |
| 17.2(Burner-5) |
- |
0 |
|
- |
| 17.2(Burner-4) |
- |
0 |
|
- |
| 17.2(Burner-3) |
- |
0 |
|
- |
| 17.2(Burner-2) |
- |
0 |
|
- |
| 17.2(Burner-1) |
- |
0 |
|
- |
| 17.2(Sim Rating Declared) |
- |
0 |
|
- |
| 17.1.2(Total Gas Consumption) |
- |
0 |
|
- |
| 17.1(Burner-5) |
- |
3500 |
|
- |
| 17.1(Burner-4) |
- |
0 |
|
- |
| 17.1( Burner-3) |
- |
0 |
|
- |
| 17.1( Burner-2) |
- |
0 |
|
- |
| 17.1( Burner-1) |
- |
0 |
|
- |
| 17.1(Rating Declared) |
- |
0 |
|
- |
| 15.2(Fragmentation test of the toughened glass to ) |
- |
500 |
|
- |
| 15.1(Verification of the strength of the gas stove surface of the toughened glass top against thermal stress) |
- |
500 |
|
- |
| 15(Width wise deflection) |
- |
1500 |
|
- |
| 15(Length wise deflection) |
- |
0 |
|
- |
| 15(Vertical Deflection) |
- |
0 |
|
- |
| 14.5(The position of the gas inlet shall allow connection to a gas supply on either side of the appliances, the rear end or bottom is also permitted. It shall be possible to change gas inlet from one side to other side easily by standard tools.) |
- |
0 |
|
- |
| 14.4(Any other connection made from the main gas rail shall be only metallic.) |
- |
0 |
|
- |
| 14.4(The external surface of the gas rail shall be treated to resist corrosion) |
- |
0 |
|
- |
| 14.4(The wall thickness of main gas rail) |
- |
0 |
|
- |
| 14.4(The pipe/tube used for main gas rail shall be of mild steel) |
- |
0 |
|
- |
| 14.3(Screwed gas Inlet and outlet connections shall confirm to IS:554, Declared by party) |
- |
0 |
|
- |
| 14.2((e)) |
- |
0 |
|
- |
| 14.2((d)) |
- |
0 |
|
- |
| 14.2(( c)) |
- |
0 |
|
- |
| 14.2((b)) |
- |
0 |
|
- |
| 14.2(Shape of Nozzles as per fig. 3 : (a)) |
- |
0 |
|
- |
| 14.2(Where Nozzles for flexible tubing are fitted, they shall be so positioned as to facilitate fitting of the tubing and also to prevent heating of the tubing to more than 60°C) |
- |
0 |
|
- |
| 14.1(Nozzle shall be machined from free cutting brass, MS, SS, Zinc) |
- |
0 |
|
- |
| 13(All gas carrying parts of the appliances should be sound and these parts when connected to form complete assembly shall also be sound against any gas leakage. The complete assembly shall be checked at 14.71 kN/m²) |
- |
0 |
|
- |
| 12.1.2(The material of the pan support shall be metallic.) |
- |
0 |
|
- |
| 12.1.1(Loose Pan support shall be so designed that it is not possible to place them firmly in other than proper position) |
- |
0 |
|
- |
| 12.1(Prongs of the Support shall have suitable taper to accommodate round bottom pans.) |
- |
0 |
|
- |
| 12.1(The design of the pan supports shall be such that it is practicable to support a pan of 100 mm diameter over at least one top burner without the use of loose rings and such that 125 mm diameter vessel remains stable over each burner. ) |
- |
0 |
|
- |
| 11.7(The appliance comprising two or more burners shall include one burner having a rating of at least 1450 kCal/hr, based on net calorific value of the gas (When using domestic PNG)) |
- |
0 |
|
- |
| 11.6(For Burners having centre flame, provision shall be made to protect the centre flame from pan resting directly on burner top and smothering the centre flame. ) |
- |
0 |
|
- |
| 11.5(If the burner is made and assembled in two or more parts they shall be so designed to provide proper self locating arrangement so that they are always reassembled to its original design preventing any maladjustment in their assembly. This shall also be applicable for primary air regulators.) |
- |
0 |
|
- |
| 11.4(If primary air regulators are used, they shall be so designed that they are not easily maladjusted by the user and the construction shall be such that primary air adjustment can be made with the burner in place.) |
- |
0 |
|
- |
| 11.3(The tightness of the joints in the burner assembly shall not be depended upon adhesives or any kind of packing.) |
- |
0 |
|
- |
| 11.2(The Burner supports shall be rigid and shall be fixed in their place. Their construction shall ensure the stability of the burners and shall prevent their undue movement in a horizontal plane.) |
- |
0 |
|
- |
| 11.1(The construction of the burners and the assembly shall allow their dismantling from the supports easily with or without the use of tools) |
- |
0 |
|
- |
| 10.2(The Size of the jet in Litres per hour of flow of PNG at STP conditions shall be impressed upon it.) |
- |
0 |
|
- |
| 10.1(Dimension- Threads) |
- |
0 |
|
- |
| 10.1(Dimension- Projection from the face of mounting, Nominal) |
- |
0 |
|
- |
| 10.1(Dimension- Across Flats) |
- |
0 |
|
- |
| 10.1(The Injector Jets shall be fixed calibrated type and it shall not be possible to loosen them without the use of tools.) |
- |
0 |
|
- |
| 9.12(The noting means adopted shall be sufficiently robust to withstand normal use without distortion or damage.) |
- |
0 |
|
- |
| 9.11.1(Simmer flame shall be obtained by fixed simmer orifice.) |
- |
0 |
|
- |
| 9.11(Taps having an 'OFF' position shall have positive stops at the 'OFF' and simmer position except that special purpose taps (for appliance incorporating auto or self ignition device)) |
- |
0 |
|
- |
| 9.1(Screw-down valves shall be so designed that it is impossible to withdraw completely the valve stem in the normal operation of the tap.) |
- |
0 |
|
- |
| 9.9(Screws nuts etc., which regulate the tension of taps valve or springs shall not loosen in operation of the appliance. It shall not be possible to cause a leak during normal manual operation of tap.) |
- |
0 |
|
- |
| 9.8(All controls or taps shall be easy to operate at all temperatures normally attained in use) |
- |
0 |
|
- |
| 9.7(C1) |
- |
0 |
|
- |
| 9.7(B1) |
- |
0 |
|
- |
| 9.7(A1) |
- |
0 |
|
- |
| 9.7(D) |
- |
0 |
|
- |
| 9.7(C) |
- |
0 |
|
- |
| 9.7(B) |
- |
0 |
|
- |
| 9.7(A) |
- |
0 |
|
- |
| 9.7(Dimension of Taper plugs in off position:) |
- |
0 |
|
- |
| 9.6(Each taper plug tap shall be spring loaded to maintain a gas tight fit. Helical springs fitted in taps and valves shall have flattened ends, which shall be rounded before fitting.) |
- |
0 |
|
- |
| 9.5.1(Taps shall be lubricated with suitable grease, resistant to the action of the gas and capable of operating at the maximum temperature of 110°C.) |
- |
0 |
|
- |
| 9.5(Taps shall be so made that in normal use and reasonable application of lubricant, the gas passages do not become blocked.) |
- |
0 |
|
- |
| 9.4(Preferably all taps (Excluding pilot taps) should lock in the off position, but in all cases it shall be impossible to handle or tap to move accidentally…. ) |
- |
0 |
|
- |
| 9.3(When Taps are fitted with adjustable stops, there shall be means of looking the stops in position. If screws are used for this purpose, they shall not lead into gas passages.) |
- |
0 |
|
- |
| 9.2(Taps shall be designed so that when placed in any position and viewed from a distance of 3 m, will definitely indicate whether the valve is open, closed or in intermediate position.) |
- |
0 |
|
- |
| 9.2(All Taps shall close in the same direction. The direction of rotation of knob from off-on-simmer shall be anti-clockwise.) |
- |
0 |
|
- |
| 9.2(The 'ON' "OFF" and any fixed position of tap handles shall be clearly and durably indicated or shall be obvious by design or position else some indication shall be provided.) |
- |
0 |
|
- |
| 9.1(The Appliance shall have at least one tap for each burner) |
- |
0 |
|
- |
| 8.7(The external Finished surfaces shall be easily cleanable.) |
- |
0 |
|
- |
| 8.6(All springs, screws, nuts and bolts which are visible or to be removed for maintenance, shall be of corrosion-resistant material or treated to resist corrosion.) |
- |
0 |
|
- |
| 8.5(Concealed Gas Supplies: Concealed tubular fittings liable to corrode shall be protected by bituminous paint or other equally protective material.) |
- |
0 |
|
- |
| 8.4 (b)(Resistance to Heating) |
- |
0 |
|
- |
| 8.4 (a)(Resistance to Abrasion) |
- |
0 |
|
- |
| 8.3.3(Corrosion Resistance test) |
- |
0 |
|
- |
| 8.3.2(Adhesion Test) |
- |
0 |
|
- |
| 8.3.1(Thickness of Chromium coating) |
- |
0 |
|
- |
| 8.3(Thickness of Nickel coating of the top flat surface of the body of electroplated stove.) |
- |
0 |
|
- |
| 8.2(Vitreous enameled component shall meet the requirement when tested in accordance with Annex E of IS:5116) |
- |
0 |
|
- |
| 8.1(The finishes shall, on visual examination, show no defects, such as pin-holes, blisters, roughness or exposed area of metal, which give rise to undualy rapid deterioration in use.) |
- |
0 |
|
- |
| 8.1(Parts, which will come in contact with the foodstuff, shall be capable of being hygienically cleaned.) |
- |
0 |
|
- |
| 8.1(The Finish of exposed parts shall be durable, easy to clean and not subject to excessive deterioration in normal use.) |
- |
0 |
|
- |
| 7(Rigidity and Stability : The appliance shall be so designed that it remains stable and shall not be easily overturned.) |
- |
0 |
|
- |
| 6.7(Thickness of Sheet) |
- |
0 |
|
- |
| 6.6(All nuts, bolts and fittings having spanner flats shall be capable of being moved by suitable spanner or be readily accessible to an adjustable spanner.) |
- |
0 |
|
- |
| 6.5(Parts, which are intented to be removable by the user, shall be easy to replace correctly and difficult to assemble incorrectly.) |
- |
0 |
|
- |
| 6.4(Burners and parts of Burner only of same rating , model and make shall be interchangeable or replaceable without effecting performance.) |
- |
0 |
|
- |
| 6.3(Burner ports shall be so designed and located that in normal use spilage of food shall not cause internal fouling of mixing tube and or blockage of injector jet.) |
- |
0 |
|
- |
| 6.2(The relative distance between the centres of the adjoining burner-) |
- |
0 |
|
- |
| 6.2(the parts of the burner shall not become disconnected during operation of the appliance.) |
- |
0 |
|
- |
| 6.1(The appliance, including all the component parts, shall be easy to clean and maintain in good working order, there shall be easy access to the accessories and controls for maintenance and adjustment.) |
- |
0 |
|
- |
| 5.8.3(The number of glass fragments contained in a 50 mm side square, when tested as Cl. 15.2) |
- |
0 |
|
- |
| 5.8.3(Toughened glass shall fragment into small particles.) |
- |
0 |
|
- |
| 5.8.2(Pan support for an uncovered burner in contact with the glass ceramic surface.The surface area of the pan support in contact with the glass ceramic) |
- |
0 |
|
- |
| 5.8.2(The toughened glass top shall ensure durability against damage in normal use) |
- |
0 |
|
- |
| 5.8.2(The means to hold the glass top of the gas stove shall not allow any stress or risk of mechanical change to the glass top.) |
- |
0 |
|
- |
| 5.8.1(Toughened glass top including their edges or corners shall not have fissures or scratches) |
- |
0 |
|
- |
| 5.7(Drip tray if provided shall be made of non-corrosive material) |
- |
0 |
|
- |
| 5.6(Meltiing poin of metal used in oven, griller or auxilliary or anyother combination) |
- |
0 |
|
- |
| 5.6(Melting point of metal for burner top) |
- |
0 |
|
- |
| 5.5(The main body of the burner including mixer head, mixing tube and burner head shall be of substantial and durable construction) |
- |
0 |
|
- |
| 5.4(Change in weight or volume of a non metallic material, when immerse in n-Pentane or PNG for 72 hours) |
- |
0 |
|
- |
| 5.3(Mercurous Nitrate test for copper and copper alloy Parts) |
- |
0 |
|
- |
| 5.2(The burner parts shall not melt or distort when burner is operated with flames flashed back for half an hour in the mixing tube.) |
- |
0 |
|
- |
| 5.1.1(Plastic components which are liable to heating (For example, tap handles push buttons etc.) shall be free of fissures, distortion, blemishes and discolouration) |
- |
0 |
|
- |
| 5.1(The use of low pressure rubber or plastic tubing fitted or pushed on nozzle is not recommended.) |
- |
0 |
|
- |
| 5.1(If flexible tubing is used, it shall not be fitted on the outlet side of any control which is capable of cutting of the gas completely, except where screwed metal connection are fitted.) |
- |
0 |
|
- |
| 5.1(The appliance shall be free from swarf, grit and other foreign matters.) |
- |
0 |
|
- |
| 4.3(No pressure regulator shall be included as part of the stove.) |
- |
0 |
|
- |
| 4.2(Rivets, Fastening screws and plugs , etc. shall not lead into gas passages.) |
- |
0 |
|
- |
| 4.1(The construction of all the parts of equipment shall be sound and of high standard of workmanship and appropriate finish. The construction shall ensure durability and shall comply with the safety requirements.) |
- |
0 |
|
- |
| 4.1(General) |
- |
0 |
|
- |
| 4.2(General) |
- |
0 |
|
- |
| 4.3(General) |
- |
0 |
|
- |
| 5.1(Materials) |
- |
0 |
|
- |
| 5.1(Materials) |
- |
0 |
|
- |
| 5.1(Materials) |
- |
0 |
|
- |
| 5.1(Materials) |
- |
0 |
|
- |
| 5.1.1(Materials) |
- |
0 |
|
- |
| 5.2(Materials) |
- |
0 |
|
- |
| 5.3(Materials) |
- |
0 |
|
- |
| 5.4(Materials) |
- |
0 |
|
- |
| 5.5(Materials) |
- |
0 |
|
- |
| 5.5(Materials) |
- |
0 |
|
- |
| 5.5(Materials) |
- |
0 |
|
- |
| 5.7(Materials) |
- |
0 |
|
- |
| 5.8.1(Materials) |
- |
0 |
|
- |
| 26(Thermal Efficiency) |
- |
0 |
|
- |
| 5.8.2 (a)(Materials) |
- |
0 |
|
- |
| 5.8.2 (a)(Materials) |
- |
0 |
|
- |
| 5.8.2 (a)(Materials) |
- |
0 |
|
- |
| 26(Thermal Efficiency) |
- |
0 |
|
- |
| 5.8.2 (a)(Materials) |
- |
0 |
|
- |
| 5.8.2 (a)(Materials) |
- |
0 |
|
- |
| 26(Thermal Efficiency) |
- |
0 |
|
- |
| 5.8.2 (a)(Materials) |
- |
0 |
|
- |
| 26(Thermal Efficiency) |
- |
0 |
|
- |
| 5.8.2 (b)(Materials) |
- |
0 |
|
- |
| 26(Thermal Efficiency) |
- |
0 |
|
- |
| 5.8.2 (c )(Materials) |
- |
0 |
|
- |
| 25.2(Fire Hazard and Limiting Temperature) |
- |
0 |
|
- |
| 5.8.2 (d)(Materials) |
- |
0 |
|
- |
| 25.1(Fire Hazard and Limiting Temperature) |
- |
0 |
|
- |
| 5.8.2 (d)(Materials) |
- |
0 |
|
- |
| 25.1(Fire Hazard and Limiting Temperature) |
- |
0 |
|
- |
| 25.1(Fire Hazard and Limiting Temperature) |
- |
0 |
|
- |
| 5.8.2 (e)(Materials) |
- |
0 |
|
- |
| 25.1(Fire Hazard and Limiting Temperature) |
- |
0 |
|
- |
| 5.8.2 (e)(Materials) |
- |
0 |
|
- |
| 5.8.2 (e)(Materials) |
- |
0 |
|
- |
| 24.2(Combustion) |
- |
0 |
|
- |
| 5.8.2 (e)(Materials) |
- |
0 |
|
- |
| 24.1(Combustion) |
- |
0 |
|
- |
| 5.8.2 (e)(Materials) |
- |
0 |
|
- |
| 24.1(Combustion) |
- |
0 |
|
- |
| 5.8.3 (a)(Materials) |
- |
0 |
|
- |
| 23(Resistance to Draught) |
- |
0 |
|
- |
| 5.8.3 (b)(Materials) |
- |
0 |
|
- |
| 5.8.3 (c)(Materials) |
- |
0 |
|
- |
| 22(Formation of soot) |
- |
0 |
|
- |
| 21(Flash Back) |
- |
0 |
|
- |
| 5.8.3 (d)(Materials) |
- |
0 |
|
- |
| 20(Noise Control) |
- |
0 |
|
- |
| 5.8.3 (e)(Materials) |
- |
0 |
|
- |
| 5.8.3 (f)(Materials) |
- |
0 |
|
- |
| 19.3(Flame Stability) |
- |
500 |
|
- |
| 6.1(Design for Maintenance) |
- |
0 |
|
- |
| 19.2(Flame Stability) |
- |
0 |
|
- |
| 6.1(Design for Maintenance) |
- |
0 |
|
- |
| 19.1.1(Flame Stability) |
- |
0 |
|
- |
| 6.2(Design for Maintenance) |
- |
0 |
|
- |
| 6.2(Design for Maintenance) |
- |
0 |
|
- |
| 19.1(Flame Stability) |
- |
0 |
|
- |
| 6.3(Design for Maintenance) |
- |
0 |
|
- |
| 18.4(Ignition and Flame Travel) |
- |
500 |
|
- |
| 6.4(Design for Maintenance) |
- |
0 |
|
- |
| 18.3(Ignition and Flame Travel) |
- |
0 |
|
- |
| 6.5(Design for Maintenance) |
- |
0 |
|
- |
| 18.2(Ignition and Flame Travel) |
- |
0 |
|
- |
| 18.1(Ignition and Flame Travel) |
- |
0 |
|
- |
| 18.1(Ignition and Flame Travel) |
- |
0 |
|
- |
| 6.6(Design for Maintenance) |
- |
0 |
|
- |
| 17.0(Gas Consumption) |
- |
0 |
|
- |
| 6.7(Design for Maintenance) |
- |
0 |
|
- |
| 17.0(Gas Consumption) |
- |
0 |
|
- |
| 17.0(Gas Consumption) |
- |
0 |
|
- |
| 17.0(Gas Consumption) |
- |
0 |
|
- |
| 17.0(Gas Consumption) |
- |
0 |
|
- |
| 17.0(Gas Consumption) |
- |
0 |
|
- |
| 17.0(Gas Consumption) |
- |
0 |
|
- |
| 17.0(Gas Consumption) |
- |
0 |
|
- |
| 17.0(Gas Consumption) |
- |
0 |
|
- |
| 9.11(Gas Taps) |
- |
0 |
|
- |
| 7.1(Rigidity and Stability) |
- |
0 |
|
- |
| 7.2(Rigidity and Stability) |
- |
0 |
|
- |
| 7.3(Rigidity and Stability) |
- |
0 |
|
- |
| 8.1(Workmanship and Finish) |
- |
0 |
|
- |
| 8.1(Workmanship and Finish) |
- |
0 |
|
- |
| 8.2 & 8.2.1(Workmanship and Finish) |
- |
0 |
|
- |
| 8.3(Workmanship and Finish) |
- |
0 |
|
- |
| 8.3(Workmanship and Finish) |
- |
0 |
|
- |
| 8.3.2(Workmanship and Finish) |
- |
0 |
|
- |
| 8.4 (a)(Workmanship and Finish) |
- |
0 |
|
- |
| 8.4 (b)(Workmanship and Finish) |
- |
0 |
|
- |
| 8.5(Workmanship and Finish) |
- |
0 |
|
- |
| 8.6(Workmanship and Finish) |
- |
0 |
|
- |
| 8.7(Workmanship and Finish) |
- |
0 |
|
- |
| 9.1(Gas Taps) |
- |
0 |
|
- |
| 9.2(Gas Taps) |
- |
0 |
|
- |
| 9.2(Gas Taps) |
- |
0 |
|
- |
| 9.2(Gas Taps) |
- |
0 |
|
- |
| 9.3(Gas Taps) |
- |
0 |
|
- |
| 9.4(Gas Taps) |
- |
0 |
|
- |
| 9.5(Gas Taps) |
- |
0 |
|
- |
| 9.11.1(Gas Taps) |
- |
0 |
|
- |
| 9.12(Gas Taps) |
- |
0 |
|
- |
| 10.1(Injector Jets) |
- |
0 |
|
- |
| 10.1 (a)(Injector Jets) |
- |
0 |
|
- |
| 10.1 (b)(Injector Jets) |
- |
0 |
|
- |
| 10.1 (c )(Injector Jets) |
- |
0 |
|
- |
| 10.1.1(Injector Jets) |
- |
0 |
|
- |
| 9.5.1(Gas Taps) |
- |
0 |
|
- |
| 10.2(Injector Jets) |
- |
0 |
|
- |
| 9.6(Gas Taps) |
- |
0 |
|
- |
| 11.1(Burners) |
- |
0 |
|
- |
| 9.7(Gas Taps) |
- |
0 |
|
- |
| 11.2(Burners) |
- |
0 |
|
- |
| 9.7(Gas Taps) |
- |
0 |
|
- |
| 11.3(Burners) |
- |
0 |
|
- |
| 9.7(Gas Taps) |
- |
0 |
|
- |
| 11.4(Burners) |
- |
0 |
|
- |
| 9.7(Gas Taps) |
- |
0 |
|
- |
| 9.7(Gas Taps) |
- |
0 |
|
- |
| 11.5(Burners) |
- |
0 |
|
- |
| 9.7(Gas Taps) |
- |
0 |
|
- |
| 11.6(Burners) |
- |
0 |
|
- |
| 9.7(Gas Taps) |
- |
0 |
|
- |
| 11.7(Burners) |
- |
0 |
|
- |
| 9.7(Gas Taps) |
- |
0 |
|
- |
| 9.8(Gas Taps) |
- |
0 |
|
- |
| 9.9(Gas Taps) |
- |
0 |
|
- |
| 9.10(Gas Taps) |
- |
0 |
|
- |
| 12.1(Pan Supports) |
- |
0 |
|
- |
| 12.1.1(Pan Supports) |
- |
0 |
|
- |
| 12.1.2(Pan Supports) |
- |
0 |
|
- |
| 13.1(Gas Soundness) |
- |
1000 |
|
- |
| 14.1(Gas Inlet Connection) |
- |
0 |
|
- |
| 14.2(Gas Inlet Connection) |
- |
0 |
|
- |
| 14.2(Gas Inlet Connection) |
- |
0 |
|
- |
| 14.2(Gas Inlet Connection) |
- |
0 |
|
- |
| 14.2(Gas Inlet Connection) |
- |
0 |
|
- |
| 14.2(Gas Inlet Connection) |
- |
0 |
|
- |
| 14.2(Gas Inlet Connection) |
- |
0 |
|
- |
| 14.2(Gas Inlet Connection) |
- |
0 |
|
- |
| 14.3(Gas Inlet Connection) |
- |
0 |
|
- |
| 14.4(Gas Inlet Connection) |
- |
0 |
|
- |
| 14.4(Gas Inlet Connection) |
- |
0 |
|
- |
| 14.4(Gas Inlet Connection) |
- |
0 |
|
- |
| 14.4(Gas Inlet Connection) |
- |
0 |
|
- |
| 14.5(Gas Inlet Connection) |
- |
0 |
|
- |
| 14.5(Gas Inlet Connection) |
- |
0 |
|
- |
| 14.5(Gas Inlet Connection) |
- |
0 |
|
- |
| 15.0(Strength and Rigidity) |
- |
0 |
|
- |
| 15.0(Strength and Rigidity) |
- |
0 |
|
- |
| 15.0(Strength and Rigidity) |
- |
0 |
|
- |
| 15.0(Strength and Rigidity) |
- |
0 |
|
- |
| 17.0(Gas Consumption) |
- |
0 |
|
- |
| 17.0(Gas Consumption) |
- |
0 |
|
- |
| 10.1.1(Injector Jet shall be made of metal , with or without ceramic tip. The melting point of the metal shall not be less than 650°C) |
- |
0 |
|
- |
|
- |
- included w.e.f 24.02.2026 |
| 797 |
Vimta labs Limited, Hyderabad
| 6102906
| IS 2997 (1964) |
Specification for air circulator type electric fans and regulators |
- |
40000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4.1(Preffered voltages) |
- |
0 |
|
- |
| 5.1(standard frequency) |
- |
0 |
|
- |
| 6.1(Number of Phases) |
- |
0 |
|
- |
| 7.1(Induction motors) |
- |
0 |
|
- |
| 8.1(Stampings ) |
- |
1000 |
|
- |
| 8.2(Enclosures) |
- |
0 |
|
- |
| 8.3(Blades) |
- |
0 |
|
- |
| 8.4(Guard) |
- |
0 |
|
- |
| 8.5(Heat Resistance) |
- |
0 |
|
- |
| 8.6(Moisture Resistance -) |
- |
0 |
|
- |
| 8.7(Bearings -) |
- |
0 |
|
- |
| 8.8(Commutator segments) |
- |
0 |
|
- |
| 8.9(Carbon brushes) |
- |
0 |
|
- |
| 8.1(Brush Holder Springs -) |
- |
0 |
|
- |
| 8.11(Supply Cord-) |
- |
0 |
|
- |
| 8.12(Cord-Grip) |
- |
0 |
|
- |
| 8.13(Protective Measures ) |
- |
0 |
|
- |
| 8.14(Protection Against Direct Contact -) |
- |
0 |
|
- |
| 8.15(Method of Mounting -) |
- |
0 |
|
- |
| 8.16(Capacitors -) |
- |
0 |
|
- |
| 8.17(Stability -) |
- |
0 |
|
- |
| 8.18(Finish -) |
- |
0 |
|
- |
| 8.19(Insulating Material -) |
- |
0 |
|
- |
| 9(Height of the Fan) |
- |
500 |
|
- |
| 10(SPEED REGULATORS ) |
- |
1000 |
|
- |
| 11(Starting) |
- |
1000 |
|
- |
| 12(Interchangeability) |
- |
1000 |
|
- |
| 13(SILENT OPERATION) |
- |
1000 |
|
- |
| 14(COMMUTATION) |
- |
1000 |
|
- |
| 15(OSCILLATING MECHANISM) |
- |
1000 |
|
- |
| 16(STANDARD OF PERFORMANCE) |
- |
0 |
|
- |
| 17(TOLERANCES ON RATINGS) |
- |
0 |
|
- |
| 18(Marking) |
- |
500 |
|
- |
| 19 a)(Type test) |
- |
0 |
|
- |
| 19 b)(Acceptance test) |
- |
0 |
|
- |
| 19 c)(Routine test) |
- |
0 |
|
- |
| 19.2(Air Delivery Test) |
- |
15000 |
|
- |
| 19.3(Temperature-Rise of Fan Motor and Regulator) |
- |
1000 |
|
- |
| 19.4(Moisture-Proofness Test) |
- |
2000 |
|
- |
| 19.5(Cord-Grip Test) |
- |
2000 |
|
- |
| 19.6(Mechanical Endurance Test for Regulator) |
- |
2000 |
|
- |
| 19.7(Power Factor Test) |
- |
1000 |
|
- |
| 19.8(ac Leakage Test) |
- |
1500 |
|
- |
| 19.9(High Voltage Test) |
- |
1500 |
|
- |
| 19.1(Insulation Resistance Test) |
- |
1500 |
|
- |
| 19.11(Earthing Continuity test) |
- |
1500 |
|
- |
| 19.12(Electrical Input Test) |
- |
1000 |
|
- |
| 19.13(Measurement of Fan Speed) |
- |
1000 |
|
- |
| 19.14(Flash Test -) |
- |
1000 |
|
- |
|
31 Mar, 2028 |
- included w.e.f 18.03.2026 |
| 798 |
Samridhi Test House Pvt. Ltd.
| 8184706
| IS 1867 (2023) |
Rubber hot water bottles - Specification (Second Revision) |
- |
20500 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl-3.1(Size) |
- |
1000 |
|
- |
| Cl-3.2(Capacity) |
- |
1000 |
|
- |
| Cl-4.1(Raw Material, Construction and Workmanship) |
- |
7500 |
|
- |
| Cl-4.2(Thickness) |
- |
500 |
|
- |
| Cl-4.3(Leakage Test) |
- |
1500 |
|
- |
| Cl-4.4.1(Before Ageing) |
- |
2500 |
|
- |
| Cl-4.4.2(After Ageing) |
- |
2500 |
|
- |
| Cl-4.4.3(After Immersion) |
- |
2500 |
|
- |
| Cl-4.5(Tension Set) |
- |
2500 |
|
- |
| Cl-5.2, Table-1 (iii)(Marking) |
- |
500 |
|
- |
|
- |
- Included w.e.f 09.02.2026 |
| 799 |
ELCA Laboratories, Navi Mumbai
| 7169736
| IS 12592 (2002) |
Precast concrete manhole cover and frame - Specification (First Revision) |
All |
15200 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 3(Grade) |
- |
500 |
|
- |
| 3(Type/Shape of Cover) |
- |
500 |
|
- |
| 4.4(Reinforcement) |
- |
500 |
|
- |
| 4.4(Reinforcement) |
- |
500 |
|
- |
| 4.5(Steel Fibres - Diameter / equivalent diameterofsteel tibres) |
- |
500 |
|
- |
| 4.5(Steel Fibres - The aspect ratio of the tibres) |
- |
500 |
|
- |
| 5.2 and Table 1(Dimensions of Frame - A) |
- |
500 |
|
- |
| 5.2 and Table 1(Dimensions of Frame - B) |
- |
500 |
|
- |
| 5.2 and Table 1(Dimensions of Frame - C) |
- |
500 |
|
- |
| 5.2 and Table 1(Dimensions of Frame - D) |
- |
500 |
|
- |
| 5.2 and Table 1(Dimensions of Frame - E) |
- |
500 |
|
- |
| 5.2 and Table 1(Dimensions of Frame - F) |
- |
500 |
|
- |
| 5.2(Dimensions of cover- Diameter) |
- |
500 |
|
- |
| 5.2(Clearance at top between the frame and the cover all round the periphery) |
- |
500 |
|
- |
| 5.2(Top surface ofthe frame and cover is in level) |
- |
500 |
|
- |
| 5.2(Suitable taper matching with taper given for the frame shall be provided to the periphery of the cover) |
- |
500 |
|
- |
| 5.2 and Fig 1(Clear cover to reinforcement) |
- |
1500 |
|
- |
| 5.2 and Fig 1(Distance of housing from the edge) |
- |
1500 |
|
- |
| 7.4.1(Edge Protection and Finishing - Frame) |
- |
1500 |
|
- |
| 7.4.1(Edge Protection and Finishing - Frame) |
- |
1500 |
|
- |
| 7.4.1(Edge Protection and Finishing - Frame) |
- |
1500 |
|
- |
| 7.4.1(Edge Protection and Finishing - Frame) |
- |
1500 |
|
- |
| 7.4.2(Edge Protection and Finishing - Cover) |
- |
1500 |
|
- |
| 7.4.2(Edge Protection and Finishing - Cover) |
- |
1500 |
|
- |
| 7.4.2(Edge Protection and Finishing - Cover) |
- |
1500 |
|
- |
| 7.4.2(Edge Protection and Finishing - Cover) |
- |
1500 |
|
- |
| 8(LIFTING HOOKS) |
- |
3000 |
|
- |
| 8(LIFTING HOOKS) |
- |
3000 |
|
- |
| 9.1(General) |
- |
1000 |
|
- |
| 9.3 and Table and
Annex C(Load Test) |
- |
8500 |
|
- |
| Clause No. 5.2, Figure 1(Typical Illustration of circular precast concrete manhole cover) |
- |
8500 |
|
- |
| Clause No. 9.3 Annex C(Adhesion between concrete and reinforcing steel) |
- |
8500 |
|
- |
| Clause No. 9.3 Annex C(Cracks at bottom side of the cover ) |
- |
8500 |
|
- |
| Clause No. 9.3 Annex C(Permanent set of cover) |
- |
8500 |
|
- |
| Clause No. 9.3, 12.3 & C-1.1, Table No. 2(2/3rd of Test Load) |
- |
8500 |
|
- |
| Clause No. 9.3, 12.3 & C-1.1, Table No. 2(Test Load) |
- |
8500 |
|
- |
| Clause No. 8(Lifting Device) |
- |
1500 |
|
- |
| Clause No. 8(Lifting Hooks (Diameter of MS rod)) |
- |
1500 |
|
- |
| Clause No. 7.4.4(Compatitbilty of Seating of cover and frame) |
- |
1500 |
|
- |
| Clause No. 7.4.2(Edge protection and finishing of cover (Thikness of MS sheet)) |
- |
1500 |
|
- |
| Clause No. 7.4.2(Edge protection and finishing of cover (Cover finish of top surface)) |
- |
1500 |
|
- |
| Clause No. 7.4.1(Edge protection and finishing of frame (Steel connectors)) |
- |
1500 |
|
- |
| Clause No. 7.4.1(Edge protection and finishing of frame (Size of mild steel flat)) |
- |
1500 |
|
- |
| Clause No. 6(Design) |
- |
1500 |
|
- |
| 3(Grade) |
- |
- |
|
- |
| 3(Type/Shape of Cover) |
- |
- |
|
- |
| 4.4(Reinforcement) |
- |
- |
|
- |
| 4.4(Reinforcement) |
- |
- |
|
- |
| 4.5(Steel Fibres - Diameter / equivalent diameterofsteel tibres) |
- |
- |
|
- |
| 4.5(Steel Fibres - The aspect ratio of the tibres) |
- |
- |
|
- |
| 5.2 and Table 1(Dimensions of Frame - A) |
- |
- |
|
- |
| 5.2 and Table 1(Dimensions of Frame - B) |
- |
- |
|
- |
| 5.2 and Table 1(Dimensions of Frame - C) |
- |
- |
|
- |
| 5.2 and Table 1(Dimensions of Frame - D) |
- |
- |
|
- |
| 5.2 and Table 1(Dimensions of Frame - E) |
- |
- |
|
- |
| 5.2 and Table 1(Dimensions of Frame - F) |
- |
- |
|
- |
| 5.2(Dimensions of cover- Diameter) |
- |
- |
|
- |
| 5.2(Clearance at top between the frame and the cover all round the periphery) |
- |
- |
|
- |
| 5.2(Top surface ofthe frame and cover is in level) |
- |
- |
|
- |
| 5.2(Suitable taper matching with taper given for the frame shall be provided to the periphery of the cover) |
- |
- |
|
- |
| 5.2 and Fig 1(Clear cover to reinforcement) |
- |
- |
|
- |
| 5.2 and Fig 1(Distance of housing from the edge) |
- |
- |
|
- |
| 7.4.1(Edge Protection and Finishing - Frame) |
- |
- |
|
- |
| 7.4.1(Edge Protection and Finishing - Frame) |
- |
- |
|
- |
| 7.4.1(Edge Protection and Finishing - Frame) |
- |
- |
|
- |
| 7.4.1(Edge Protection and Finishing - Frame) |
- |
- |
|
- |
| 7.4.2(Edge Protection and Finishing - Cover) |
- |
- |
|
- |
| 7.4.2(Edge Protection and Finishing - Cover) |
- |
- |
|
- |
| 7.4.2(Edge Protection and Finishing - Cover) |
- |
- |
|
- |
| 7.4.2(Edge Protection and Finishing - Cover) |
- |
- |
|
- |
| 8(LIFTING HOOKS) |
- |
- |
|
- |
| 8(LIFTING HOOKS) |
- |
- |
|
- |
| 9.1(General) |
- |
- |
|
- |
| 9.3 and Table and
Annex C(Load Test) |
- |
- |
|
- |
| Clause No. 5.2, Figure 1(Typical Illustration of circular precast concrete manhole cover) |
- |
- |
|
- |
| Clause No. 9.3 Annex C(Adhesion between concrete and reinforcing steel) |
- |
- |
|
- |
| Clause No. 9.3 Annex C(Cracks at bottom side of the cover ) |
- |
- |
|
- |
| Clause No. 9.3 Annex C(Permanent set of cover) |
- |
- |
|
- |
| Clause No. 9.3, 12.3 & C-1.1, Table No. 2(2/3rd of Test Load) |
- |
- |
|
- |
| Clause No. 9.3, 12.3 & C-1.1, Table No. 2(Test Load) |
- |
- |
|
- |
| Clause No. 8(Lifting Device) |
- |
- |
|
- |
| Clause No. 8(Lifting Hooks (Diameter of MS rod)) |
- |
- |
|
- |
| Clause No. 7.4.4(Compatitbilty of Seating of cover and frame) |
- |
- |
|
- |
| Clause No. 7.4.2(Edge protection and finishing of cover (Thikness of MS sheet)) |
- |
- |
|
- |
| Clause No. 7.4.2(Edge protection and finishing of cover (Cover finish of top surface)) |
- |
- |
|
- |
| Clause No. 7.4.1(Edge protection and finishing of frame (Steel connectors)) |
- |
- |
|
- |
| Clause No. 7.4.1(Edge protection and finishing of frame (Size of mild steel flat)) |
- |
- |
|
- |
| Clause No. 6(Design) |
- |
- |
|
- |
|
02 Feb, 2028 |
- Included w.e.f 24.03.2026 |
| 800 |
Vimta labs Limited, Hyderabad
| 6102906
| IS 2312 (1967) |
Specification for propeller type AC ventilating fans (First Revision) |
- |
40000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 13.1(Marking) |
- |
1000 |
|
- |
| 13.1 (a)(Marking) |
- |
0 |
|
- |
| 13.1 (b)(Marking) |
- |
0 |
|
- |
| 13.1 (c)(Marking) |
- |
0 |
|
- |
| 13.1 (d)(Marking) |
- |
0 |
|
- |
| 13.1 (e)(Marking) |
- |
0 |
|
- |
| 13.1 (f)(Marking) |
- |
0 |
|
- |
| 13.1 (g)(Marking) |
- |
0 |
|
- |
| 13.1 (h)(Marking) |
- |
0 |
|
- |
| 13.1 (j)(Marking) |
- |
0 |
|
- |
| 13.2(Marking) |
- |
0 |
|
- |
| 13.4(Marking) |
- |
0 |
|
- |
| 3.1(Sizes ) |
- |
0 |
|
- |
| 4.1(Rated Voltage) |
- |
0 |
|
- |
| 5.1(Rated frequency) |
- |
0 |
|
- |
| 6.1(Design and General Construction) |
- |
1000 |
|
- |
| 6.3(Design and General Construction) |
- |
0 |
|
- |
| 6.3(Design and General Construction) |
- |
0 |
|
- |
| 6.4(Design and General Construction) |
- |
0 |
|
- |
| 6.5(Design and General Construction) |
- |
0 |
|
- |
| 6.6(Design and General Construction) |
- |
0 |
|
- |
| 6.7(Design and General Construction) |
- |
0 |
|
- |
| 6.9(Design and General Construction) |
- |
0 |
|
- |
| 6.1(Design and General Construction) |
- |
0 |
|
- |
| 6.11(Design and General Construction) |
- |
0 |
|
- |
| 6.12(Design and General Construction) |
- |
0 |
|
- |
| 7.1(Design and General Construction) |
- |
1000 |
|
- |
| 8.1(Design and General Construction) |
- |
1000 |
|
- |
| 9(Design and General Construction) |
- |
1000 |
|
- |
| 10.1(Starting ) |
- |
1000 |
|
- |
| 11.1(Interchangeability) |
- |
1000 |
|
- |
| 14.2 & 15.1(Air Delivery) |
- |
15000 |
|
- |
| 14.3.A(Temperature-Rise (for motors)) |
- |
1000 |
|
- |
| 14.3.A(Temperature-Rise (for motors)) |
- |
0 |
|
- |
| 14.3.A(Temperature-Rise (for motors)) |
- |
0 |
|
- |
| 14.3.A(Temperature-Rise (for motors)) |
- |
0 |
|
- |
| 14.3.B(Temperature-Rise (for regulators)) |
- |
0 |
|
- |
| 14.3.B(Temperature-Rise (for regulators)) |
- |
0 |
|
- |
| 14.3.B(Moistureproofness (for regulators only)) |
- |
2000 |
|
- |
| 14.3.B(Moistureproofness (for regulators only)) |
- |
0 |
|
- |
| 14.5(Mechanical Endurance (for regulators only)) |
- |
3000 |
|
- |
| 14.1 & 14.6(Power factor) |
- |
1000 |
|
- |
| 14.7(ac leakage) |
- |
2000 |
|
- |
| 14.8(High voltage test) |
- |
1500 |
|
- |
| 14.9(Insulation-Resistance) |
- |
1500 |
|
- |
| 14.1(Earthing continuity) |
- |
1500 |
|
- |
| 14.11 & 15.1(Electrical Input) |
- |
1000 |
|
- |
| 14.12 & 16(Fan Speed) |
- |
1500 |
|
- |
| 13.1(Marking) |
- |
0 |
|
- |
| 13.1 (a)(Marking) |
- |
0 |
|
- |
| 13.1 (b)(Marking) |
- |
0 |
|
- |
| 13.1 (c)(Marking) |
- |
0 |
|
- |
| 13.1 (d)(Marking) |
- |
0 |
|
- |
| 13.1 (e)(Marking) |
- |
0 |
|
- |
| 13.1 (f)(Marking) |
- |
0 |
|
- |
| 13.1 (g)(Marking) |
- |
0 |
|
- |
| 13.1 (h)(Marking) |
- |
0 |
|
- |
| 13.1 (j)(Marking) |
- |
0 |
|
- |
| 13.2(Marking) |
- |
0 |
|
- |
| 13.4(Marking) |
- |
0 |
|
- |
| 3.1(Sizes ) |
- |
0 |
|
- |
| 4.1(Rated Voltage) |
- |
0 |
|
- |
| 5.1(Rated frequency) |
- |
0 |
|
- |
| 6.1(Design and General Construction) |
- |
0 |
|
- |
| 6.3(Design and General Construction) |
- |
0 |
|
- |
| 6.3(Design and General Construction) |
- |
0 |
|
- |
| 6.4(Design and General Construction) |
- |
0 |
|
- |
| 6.5(Design and General Construction) |
- |
0 |
|
- |
| 6.6(Design and General Construction) |
- |
0 |
|
- |
| 6.7(Design and General Construction) |
- |
0 |
|
- |
| 6.9(Design and General Construction) |
- |
0 |
|
- |
| 6.1(Design and General Construction) |
- |
0 |
|
- |
| 6.11(Design and General Construction) |
- |
0 |
|
- |
| 6.12(Design and General Construction) |
- |
0 |
|
- |
| 7.1(Design and General Construction) |
- |
0 |
|
- |
| 8.1(Design and General Construction) |
- |
0 |
|
- |
| 9(Design and General Construction) |
- |
0 |
|
- |
| 10.1(Starting ) |
- |
0 |
|
- |
| 11.1(Interchangeability) |
- |
0 |
|
- |
| 14.2 & 15.1(Air Delivery) |
- |
0 |
|
- |
| 14.3(Temperature-Rise) |
- |
0 |
|
- |
| 14.3(Temperature-Rise) |
- |
0 |
|
- |
| 14.3(Temperature-Rise) |
- |
0 |
|
- |
| 14.3(Temperature-Rise) |
- |
0 |
|
- |
| 14.3(Temperature-Rise) |
- |
0 |
|
- |
| 14.3(Temperature-Rise) |
- |
0 |
|
- |
| 14.3(Temperature-Rise) |
- |
0 |
|
- |
| 14.4(Moistureproofness (for regulators only)) |
- |
0 |
|
- |
| 14.4(Moistureproofness (for regulators only)) |
- |
0 |
|
- |
| 14.5(Mechanical Endurance (for regulators only)) |
- |
0 |
|
- |
| 14.1 & 14.6(Power factor) |
- |
0 |
|
- |
| 14.7(ac leakage) |
- |
0 |
|
- |
| 14.8(High voltage test) |
- |
0 |
|
- |
| 14.9(Insulation-Resistance) |
- |
0 |
|
- |
| 14.1(Earthing continuity) |
- |
0 |
|
- |
| 14.11 & 15.1(Electrical Input) |
- |
0 |
|
- |
| 14.12 & 16(Fan Speed) |
- |
0 |
|
- |
| 14.13(Flash Test) |
- |
1000 |
|
- |
| 12(Silent Operation) |
- |
1000 |
|
- |
| Cl-16(Tolerances on ratings) |
- |
0 |
|
- |
|
31 Mar, 2028 |
- included w.e.f 18.03.2026 |
| 801 |
INTERNATIONAL TESTING AND COMPLIANCE (OPC) PRIVATE LIMITED
| 8188026
| IS 16046 : Part 1 (2018) |
Secondary Cells and Batteries Containing Alkaline or Other Non-Acid Electrolytes ” Safety Requirements for Portable Sealed Secondary Cells and for Batteries Made from Them for Use in Portable Applications Part 1 Nickel Systems ( Second Revision ) |
- |
45000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4(Parameter Measurement Tolerances) |
- |
2000 |
|
- |
| 5(General Safety Considerations) |
- |
2000 |
|
- |
| 5.1(General) |
- |
2000 |
|
- |
| 5.2(Insulation and Wiring) |
- |
2000 |
|
- |
| 5.3(Venting) |
- |
2000 |
|
- |
| 5.4(Temperature, Voltage and Current Management) |
- |
2000 |
|
- |
| 5.5(Terminal Contacts) |
- |
2000 |
|
- |
| 5.6(Assembly of Cells into batteries) |
- |
2000 |
|
- |
| 5.7(Quality Plan) |
- |
2000 |
|
- |
| 6(Tyoe Test amd Sample Size) |
- |
2000 |
|
- |
| 7(Specific requirements and tests) |
- |
2000 |
|
- |
| 7.1(Charging procedure for test purposes) |
- |
2000 |
|
- |
| 7.2(Intended Use) |
- |
2000 |
|
- |
| 7.3(Reasonably foreseeable misuse) |
- |
2000 |
|
- |
| 8(Information for safety) |
- |
2000 |
|
- |
| 8.1(General) |
- |
2000 |
|
- |
| 8.2(Small Cell and battery safety information) |
- |
2000 |
|
- |
| 9(Marking) |
- |
2000 |
|
- |
| 9.1(Cell Marking) |
- |
2000 |
|
- |
| 9.2(Battery Marking) |
- |
2000 |
|
- |
| 9.3(Caution for ingestion of small cells and batteries) |
- |
2000 |
|
- |
| 9.4(Other information) |
- |
2000 |
|
- |
| 10(Packaging) |
- |
2000 |
|
- |
|
- |
- included w.e.f 18.03.2026 |
| 802 |
INTERNATIONAL TESTING AND COMPLIANCE (OPC) PRIVATE LIMITED
| 8188026
| IS 16046 : Part 2 (2018) |
Secondary Cells and Batteries Containing Alkaline or Other Non-Acid Electrolytes ” Safety Requirements for Portable Sealed Secondary Cells and for Batteries Made from Them for Use in Portable Applications Part 2 Lithium Systems ( Second Revision ) |
- |
45000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4(Parameter Measurement Tolerances) |
- |
2000 |
|
- |
| 5(General Safety Considerations) |
- |
2000 |
|
- |
| 5.1(General) |
- |
2000 |
|
- |
| 5.2(Insulation and Wiring) |
- |
2000 |
|
- |
| 5.3(Venting) |
- |
2000 |
|
- |
| 5.4(Temperature, Voltage and Current Management) |
- |
2000 |
|
- |
| 5.5(Terminal Contacts) |
- |
2000 |
|
- |
| 5.6(Assembly of Cells into batteries) |
- |
2000 |
|
- |
| 5.7(Quality Plan) |
- |
2000 |
|
- |
| 5.8(Battery Safety Components) |
- |
2000 |
|
- |
| 6(Type Test and Sample Size) |
- |
2000 |
|
- |
| 7(Specific requirements and tests) |
- |
2000 |
|
- |
| 7.1(Charging procedure for test purposes) |
- |
2000 |
|
- |
| 7.2(Intended Use) |
- |
2000 |
|
- |
| 7.3(Reasonably foreseeable misuse) |
- |
2000 |
|
- |
| 8(Information for safety) |
- |
2000 |
|
- |
| 8.1(General) |
- |
2000 |
|
- |
| 8.2(Small Cell and battery safety information) |
- |
2000 |
|
- |
| 9(Marking) |
- |
2000 |
|
- |
| 9.1(Cell Marking) |
- |
2000 |
|
- |
| 9.2(Battery Marking) |
- |
2000 |
|
- |
| 9.3(Caution for ingestion of small cells and batteries) |
- |
2000 |
|
- |
| 9.4(Other information) |
- |
2000 |
|
- |
| 10(Packaging) |
- |
2000 |
|
- |
|
- |
- Exclusion : Clause 7.3.1 of IS 16047: Part 3 |
| 803 |
LPG Equipment Research Centre (LERC), Bengaluru
| 6141034
| IS 18380 (2023) |
DOMESTIC ETHANOL COOKSTOVE WITH FIXED AND REMOVABLE CANISTER TYPE SPECIFICATION |
- |
25000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl-4(Fuel Capacity) |
- |
500 |
|
- |
| Cl-4.1(Fixed Canister Type) |
- |
500 |
|
- |
| Cl-4.2(Removable Canister Type) |
- |
500 |
|
- |
| Cl-6.1(Materials) |
- |
500 |
|
- |
| Cl-6.2(Fuel Canister) |
- |
1000 |
|
- |
| Cl-6.3(Plastic components) |
- |
500 |
|
- |
| Cl-6.4(Cookstoves body) |
- |
500 |
|
- |
| Cl-6.5(Holding part/handle of the lever) |
- |
500 |
|
- |
| Cl-6.6(Fuel Tank) |
- |
500 |
|
- |
| Cl-7(Shape and Dimensions) |
- |
500 |
|
- |
| Cl-8(Construction) |
- |
500 |
|
- |
| Cl-10(Workmanship and Finish) |
- |
500 |
|
- |
| Cl-11(Stove Lever) |
- |
500 |
|
- |
| Cl-12(Pan Supports) |
- |
500 |
|
- |
| Cl-13(Strength and Rigidity of body of the Cookstove) |
- |
1500 |
|
- |
| Cl-15.1(Fixed/Removable Canister Type) |
- |
500 |
|
- |
| Cl-16(Thermal Efficiency) |
- |
5000 |
|
- |
| Cl-17(Surface Temperature) |
- |
3000 |
|
- |
| Cl-18(Combustion Efficiency) |
- |
5000 |
|
- |
| Cl-19(Resistance to Draught) |
- |
1000 |
|
- |
| Cl-20(Fuel Creep) |
- |
1000 |
|
- |
| Cl-22(Instructions) |
- |
500 |
|
- |
|
- |
- Included w.e.f 09.02.2026 |
| 804 |
INDIAN TESTING LABORATORY PRIVATE LIMITED, GREATER NOIDA
| 8171306
| IS 1269 : Part 2 (1997) |
Legal metrology - Material measures of length: Part 2 steel tape measures |
- |
20000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 3(Nominal Length) |
- |
500 |
|
- |
| 4(Materials) |
- |
300 |
|
- |
| 4(Materials) |
- |
300 |
|
- |
| 4(Materials) |
- |
300 |
|
- |
| 5(Construction) |
- |
300 |
|
- |
| 5(Construction) |
- |
300 |
|
- |
| 5(Construction) |
- |
300 |
|
- |
| 5(Construction) |
- |
300 |
|
- |
| 5(Construction) |
- |
300 |
|
- |
| 5(Construction) |
- |
300 |
|
- |
| 5(Construction) |
- |
300 |
|
- |
| 5(Construction) |
- |
300 |
|
- |
| 5(Construction) |
- |
300 |
|
- |
| 6.1(Graduation) |
- |
300 |
|
- |
| 6.2(Graduation) |
- |
300 |
|
- |
| 6.2(Graduation) |
- |
300 |
|
- |
| 6.2(Graduation) |
- |
300 |
|
- |
| 6.2(Graduation) |
- |
300 |
|
- |
| 6.3(Graduation) |
- |
300 |
|
- |
| 6.3.1(Graduation) |
- |
300 |
|
- |
| 6.3.2(Graduation) |
- |
300 |
|
- |
| 6.4(Graduation) |
- |
300 |
|
- |
| 6.5(Graduation) |
- |
300 |
|
- |
| 6.6(Graduation) |
- |
300 |
|
- |
| 6.7(Graduation) |
- |
300 |
|
- |
| 6.7(Graduation) |
- |
300 |
|
- |
| 6.7(Graduation) |
- |
300 |
|
- |
| 6.8(Graduation) |
- |
300 |
|
- |
| 6.9(Graduation) |
- |
300 |
|
- |
| 6.1O(Graduation) |
- |
300 |
|
- |
| 6.1O(Graduation) |
- |
300 |
|
- |
| 6.1O(Graduation) |
- |
300 |
|
- |
| 6.1O(Graduation) |
- |
300 |
|
- |
| 6.1O(Graduation) |
- |
300 |
|
- |
| 7.1.1(Numbering-General Requirements) |
- |
400 |
|
- |
| 7.1.2(Numbering-General Requirements) |
- |
400 |
|
- |
| 7.1.3(Numbering-General Requirements) |
- |
400 |
|
- |
| 7.2(Numbering) |
- |
400 |
|
- |
| 7.2(Numbering) |
- |
400 |
|
- |
| 7.3(Numbering) |
- |
400 |
|
- |
| 7.4(Numbering) |
- |
400 |
|
- |
| 7.5(Numbering) |
- |
400 |
|
- |
| 7.6(Numbering) |
- |
400 |
|
- |
| 7.6(Numbering) |
- |
400 |
|
- |
| 7.6(Numbering) |
- |
400 |
|
- |
| 7.7(Numbering) |
- |
400 |
|
- |
| 8(Accuracy Classes & Maximum permissible error) |
- |
400 |
|
- |
| 8(Accuracy Classes & Maximum permissible error) |
- |
400 |
|
- |
| 8(Accuracy Classes & Maximum permissible error) |
- |
400 |
|
- |
| 8(Accuracy Classes & Maximum permissible error) |
- |
400 |
|
- |
| 9.1.1(Automtic Winding Device- Winding Device) |
- |
300 |
|
- |
| 9.1.1(Automtic Winding Device- Winding Device) |
- |
300 |
|
- |
| 9.1.1(Automtic Winding Device- Winding Device) |
- |
300 |
|
- |
| 9.1.2(Automtic Winding Device- Case) |
- |
300 |
|
- |
| 9.1.2(Automtic Winding Device- Case) |
- |
300 |
|
- |
| 9.1.2(Automtic Winding Device- Case) |
- |
300 |
|
- |
| 9.2.1(Hand Winding Device- Handle) |
- |
200 |
|
- |
| 9.2.2(Hand Winding Device- Reel) |
- |
200 |
|
- |
| 9.2.3(Hand Winding Device- Case) |
- |
200 |
|
- |
| 9.3(Winding Device) |
- |
200 |
|
- |
| 9.3.1(Winding Device) |
- |
200 |
|
- |
| 8(Accuracy Classes & Maximum permissible error) |
- |
200 |
|
- |
| 3(Nominal Length) |
- |
- |
|
- |
| 4(Materials) |
- |
- |
|
- |
| 4(Materials) |
- |
- |
|
- |
| 4(Materials) |
- |
- |
|
- |
| 5(Construction) |
- |
- |
|
- |
| 5(Construction) |
- |
- |
|
- |
| 5(Construction) |
- |
- |
|
- |
| 5(Construction) |
- |
- |
|
- |
| 5(Construction) |
- |
- |
|
- |
| 5(Construction) |
- |
- |
|
- |
| 5(Construction) |
- |
- |
|
- |
| 5(Construction) |
- |
- |
|
- |
| 5(Construction) |
- |
- |
|
- |
| 6.1(Graduation) |
- |
- |
|
- |
| 6.2(Graduation) |
- |
- |
|
- |
| 6.2(Graduation) |
- |
- |
|
- |
| 6.2(Graduation) |
- |
- |
|
- |
| 6.2(Graduation) |
- |
- |
|
- |
| 6.3(Graduation) |
- |
- |
|
- |
| 6.3.1(Graduation) |
- |
- |
|
- |
| 6.3.2(Graduation) |
- |
- |
|
- |
| 6.4(Graduation) |
- |
- |
|
- |
| 6.5(Graduation) |
- |
- |
|
- |
| 6.6(Graduation) |
- |
- |
|
- |
| 6.7(Graduation) |
- |
- |
|
- |
| 6.7(Graduation) |
- |
- |
|
- |
| 6.7(Graduation) |
- |
- |
|
- |
| 6.8(Graduation) |
- |
- |
|
- |
| 6.9(Graduation) |
- |
- |
|
- |
| 6.1O(Graduation) |
- |
- |
|
- |
| 6.1O(Graduation) |
- |
- |
|
- |
| 6.1O(Graduation) |
- |
- |
|
- |
| 6.1O(Graduation) |
- |
- |
|
- |
| 6.1O(Graduation) |
- |
- |
|
- |
| 7.1.1(Numbering-General Requirements) |
- |
- |
|
- |
| 7.1.2(Numbering-General Requirements) |
- |
- |
|
- |
| 7.1.3(Numbering-General Requirements) |
- |
- |
|
- |
| 7.2(Numbering) |
- |
- |
|
- |
| 7.2(Numbering) |
- |
- |
|
- |
| 7.3(Numbering) |
- |
- |
|
- |
| 7.4(Numbering) |
- |
- |
|
- |
| 7.5(Numbering) |
- |
- |
|
- |
| 7.6(Numbering) |
- |
- |
|
- |
| 7.6(Numbering) |
- |
- |
|
- |
| 7.6(Numbering) |
- |
- |
|
- |
| 7.7(Numbering) |
- |
- |
|
- |
| 8(Accuracy Classes & Maximum permissible error) |
- |
- |
|
- |
| 8(Accuracy Classes & Maximum permissible error) |
- |
- |
|
- |
| 8(Accuracy Classes & Maximum permissible error) |
- |
- |
|
- |
| 8(Accuracy Classes & Maximum permissible error) |
- |
- |
|
- |
| 9.1.1(Automtic Winding Device- Winding Device) |
- |
- |
|
- |
| 9.1.1(Automtic Winding Device- Winding Device) |
- |
- |
|
- |
| 9.1.1(Automtic Winding Device- Winding Device) |
- |
- |
|
- |
| 9.1.2(Automtic Winding Device- Case) |
- |
- |
|
- |
| 9.1.2(Automtic Winding Device- Case) |
- |
- |
|
- |
| 9.1.2(Automtic Winding Device- Case) |
- |
- |
|
- |
| 9.2.1(Hand Winding Device- Handle) |
- |
- |
|
- |
| 9.2.2(Hand Winding Device- Reel) |
- |
- |
|
- |
| 9.2.3(Hand Winding Device- Case) |
- |
- |
|
- |
| 9.3(Winding Device) |
- |
- |
|
- |
| 9.3.1(Winding Device) |
- |
- |
|
- |
| 8(Accuracy Classes & Maximum permissible error) |
- |
- |
|
- |
|
15 Aug, 2028 |
- Included w.e.f. 26.02.2026 |
| 805 |
PIONEER TESTING LABORATORY PRIVATE LIMITED
| 8176806
| IS 15683 (2018) |
Portable Fire Extinguishers — Performance and Construction — Specification ( First Revision ) |
All Type |
289000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl. 5.3.1(Filling Requirements) |
- |
8000 |
|
- |
| Cl. 5.3.2(Filling Requirements) |
- |
8000 |
|
- |
| Cl. 5.3.2(Filling Requirements) |
- |
0 |
|
- |
| Cl. 5.3.2(Filling Requirements) |
- |
0 |
|
- |
| Cl. 5.3.2(Filling Requirements) |
- |
0 |
|
- |
| Cl. 5.3.2(Filling Requirements) |
- |
0 |
|
- |
| Cl. 5.3.2(Filling Requirements) |
- |
0 |
|
- |
| Cl. 5.3.3(Capacities) |
- |
1000 |
|
- |
| Cl. 5.3.3(Capacities) |
- |
0 |
|
- |
| Cl. 5.3.3(Capacities) |
- |
0 |
|
- |
| Cl. 5.3.3(Capacities) |
- |
0 |
|
- |
| Cl. 5.3.3(Capacities) |
- |
0 |
|
- |
| Cl. 5.3.3(Capacities) |
- |
0 |
|
- |
| Cl. 6(PRESSURE REQUIREMENTS FOR LOW PRESSURE EXTINGUISHERS) |
- |
8000 |
|
- |
| Cl. 6(PRESSURE REQUIREMENTS FOR LOW PRESSURE EXTINGUISHERS) |
- |
0 |
|
- |
| Cl. 7.2 - Table 1(GENERAL OPERATING PERFORMANCE REQUIREMENTS) |
- |
1000 |
|
- |
| Cl. 7.2 - Table 1(GENERAL OPERATING PERFORMANCE REQUIREMENTS) |
- |
0 |
|
- |
| Cl. 7.3(Resistance to Temperature changes) |
- |
1000 |
|
- |
| Cl 7.4.3( Leakage Test) |
- |
3000 |
|
- |
| Cl 7.5.1(Impact Resistance Test) |
- |
1000 |
|
- |
| Cl. 7.1(GENERAL OPERATING PERFORMANCE REQUIREMENTS) |
- |
1000 |
|
- |
| Cl 7.5.2(Vibration Resistance Test) |
- |
2000 |
|
- |
| Cl 7.6(Resistance to Corrosion) |
- |
2000 |
|
- |
| Cl 7.7(Tapping Test) |
- |
2000 |
|
- |
| Cl 7.8(Intermittent Discharge Test) |
- |
2000 |
|
- |
| Cl 7.8(Intermittent Discharge Test) |
- |
0 |
|
- |
| Cl 8.1(Rating Suitability for the Various Classes of Fire) |
- |
5500 |
|
- |
| Cl 8.6(Electrical Conductivity of Extinguisher Discharge) |
- |
25000 |
|
- |
| Cl 9(CONSTRUCTION REQUIREMENTS) |
- |
2000 |
|
- |
| Cl 9.2.2(Burst Test) |
- |
2000 |
|
- |
| Cl 9.2.3(Crushing Test) |
- |
2000 |
|
- |
| Cl 9.2.4(Pressure Cycling Test) |
- |
2000 |
|
- |
| Cl 9.2.5(Welded Low Carbon Steel Cylinder) |
- |
2000 |
|
- |
| Cl 9.2.6(Stainless Steel Cylinders) |
- |
2000 |
|
- |
| Cl 9.2.7(Aluminium Cylinders) |
- |
2000 |
|
- |
| Cl 9.3(Carrying Handle) |
- |
1000 |
|
- |
| Cl 9.4(Mounting) |
- |
1000 |
|
- |
| Cl 9.5(Caps, Valves and Closures) |
- |
1000 |
|
- |
| Cl 9.7.1(Requirements for Plastics Components) |
- |
2000 |
|
- |
| Cl 9.7.2(Requirements for Plastics Components) |
- |
2000 |
|
- |
| Cl 9.7.3(Requirements for Plastics Components) |
- |
2000 |
|
- |
| Cl 9.8(Hose Assemblies) |
- |
2000 |
|
- |
| Cl 9.8(Hose Assemblies) |
- |
0 |
|
- |
| Cl 9.9 - Table 10(Method of Operation) |
- |
2000 |
|
- |
| Cl 9.10(Safety-Locking Devices) |
- |
1000 |
|
- |
| Cl 9.11.1(Requirements for Pressure Gauges and Indicators for Low-Pressure Extinguishers) |
- |
3000 |
|
- |
| Cl 9.11.2(Calibration Test - Gauges and Indicators) |
- |
3000 |
|
- |
| Cl 9.11.3(Burst Strength Test — Gauges and Indicators) |
- |
2000 |
|
- |
| Cl 9.11.4(Water Resistance Test — Gauges and Indicators) |
- |
2000 |
|
- |
| Cl 9.12(Dip-Tubes and Filters — Water-Based Extinguishers) |
- |
1000 |
|
- |
| Cl 9.13(Horn Test for Carbon Dioxide (CO2) Extinguishers) |
- |
1000 |
|
- |
| Cl 9.14(Requirements for Extinguishants Filled in the Extinguisher) |
- |
1000 |
|
- |
| Cl 10(MARKING AND COLOUR) |
- |
1000 |
|
- |
| 9.6(Safety Device) |
- |
1000 |
|
- |
| 9.2.8(Composite Cylinder) |
- |
1000 |
|
- |
| 9.2.7(Measure Thickness of the cylinder (Aluminium body)) |
- |
1000 |
|
- |
| 9.2.6.3 (Measure Thickness of the cylinder (S.S. Body)) |
- |
1000 |
|
- |
| 9.2.6.1 & 9.2.6.2 (Carbon composition of stainless steel cylinder) |
- |
1000 |
|
- |
| 9.2.5.3, (Measure Thickness of the cylinder) |
- |
1000 |
|
- |
| 9.2.5.1 & 9.2.5.2(Composition of welded low carbon steel cylinders) |
- |
1000 |
|
- |
| 9.2.1.7(Construction requirement for the bottom of the extinguisher) |
- |
1000 |
|
- |
| 9.2.1.6(Type of threads on parts made of plastic component joining metal parts) |
- |
1000 |
|
- |
| 9.2.1.4(Construction requirement of Neck Ring) |
- |
1000 |
|
- |
| 9.2.1.3(Requirement of Welding) |
- |
1500 |
|
- |
| 9.2.1.2(Construction requirement for stand vertically upright position) |
- |
2000 |
|
- |
| 9.1(General Requirements of High Pressure Extinguisher) |
- |
5000 |
|
- |
| 9.2.1.5(Cast Analysis Certifcate) |
- |
2000 |
|
- |
| 8.8(Electrical Conductivity of Extinguishers Discharge ) |
- |
2000 |
|
- |
| 8.1.5, 8.2.2(C) , 8.6, 8.7(Class F Splash Test) |
- |
25000 |
|
- |
| 8.1.4 & 8.5(Class D Test fire) |
- |
17000 |
|
- |
| 8.1.2, 8.2.2 b) & 8.4(Class B Fire Test) |
- |
75000 |
|
- |
| 8.1.1, 8.2.2 a) & 8.3(Class A Fire Test) |
- |
11000 |
|
- |
| 7.6.1(Internal Corrosion Test Test is applicable only for water based & clean agent PFEs) |
- |
2000 |
|
- |
| 7.6.1(External Corrosion Test for all types of extinguishers) |
- |
0 |
|
- |
| 7.4.2(Leakage Test) |
- |
2000 |
|
- |
| 7.4.1.(Retention of charge following partial discharge) |
- |
2000 |
|
- |
| 6.2(Determination of Minimum Burst Pressure) |
- |
2000 |
|
- |
| 6.1(Determination of Test Pressure) |
- |
2000 |
|
- |
| 3.6 & 9.2.1.8(Determination of Maximum Service Pressure ) |
- |
2000 |
|
- |
| 3.5 & 9.2.1.1(Determination of Service Pressure ) |
- |
2000 |
|
- |
| 7.6.2(Internal Corrosion Test for Extinguishers Using Water-Based Medium and Clean Agent) |
- |
1000 |
|
- |
| 9.14.1(Content of Mono Ammonium Phosphate) |
- |
2000 |
|
- |
| 9.14.2(Content of Sodium Bicarbonate/Potassium Picarbonate for BC Powder) |
- |
2000 |
|
- |
| 9.14.3(Surface Tension of Foam Solution) |
- |
1000 |
|
- |
| 9.8.2(Requirement of hose and coupling system) |
- |
1000 |
|
- |
| 9.8.3("Requirement of Burst Pressure of Hose fitted with shut-off nozzle
") |
- |
1000 |
|
- |
| 9.8.3("Requirement of Burst Pressure of Hose fitted with shut-off nozzle
for CO2 Fire Extinguisher") |
- |
0 |
|
- |
| 9.8.4(A hose assembly without a shut-off nozzle shall be capable of withstanding, without leakage, a pressure equal to the extinguisher test pressure i.e Max (1.43 × Pms , 35 bar) held for at least 30 seconds.) |
- |
1000 |
|
- |
| 9.10.2(Requirement of safety device material) |
- |
1000 |
|
- |
| 9.10.3, 9.10.4, 9.10.5 & 9.10.6(Requirement of safety-locking pin or other device) |
- |
1000 |
|
- |
|
10 Mar, 2027 |
- Included w.e.f 01.04.2026 |
| 806 |
Vimta labs Limited, Hyderabad
| 6102906
| IS 1169 (1967) |
Specification for electric pedestal type fans and regulators (First Revision) |
- |
30000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 18( Tolerances on rating) |
- |
0 |
|
- |
| 17(Performance Reqirement) |
- |
0 |
|
- |
| 16.14(Insulation-resistance ) |
- |
1000 |
|
- |
| 16.13(Flash Test) |
- |
0 |
|
- |
| 16.12(Measurement of Fan Speed) |
- |
1000 |
|
- |
| 16.11(Electrical Input Test) |
- |
1000 |
|
- |
| 16.1(Earthing Continuity Test) |
- |
1000 |
|
- |
| 16.9(High Voltage) |
- |
1000 |
|
- |
| 16.8(AC Leakage Test) |
- |
2000 |
|
- |
| 16.7(Power Factor) |
- |
500 |
|
- |
| 16.6(Mechanical Endurance Test (for
Regulators only)) |
- |
3000 |
|
- |
| 16.5(Cord grip test) |
- |
2000 |
|
- |
| 16.4(Moisture Proofness Test (for
Regulators only)) |
- |
2000 |
|
- |
| 16.3(Temperature-rise) |
- |
1000 |
|
- |
| 16.2(Air Delivery Test) |
- |
10000 |
|
- |
| 15(Marking) |
- |
500 |
|
- |
| 14(Oscillating Mechanism) |
- |
0 |
|
- |
| 13(Silent Operation) |
- |
750 |
|
- |
| 12(Interchangeability) |
- |
500 |
|
- |
| 11(Starting) |
- |
750 |
|
- |
| 10(Speed Regulators) |
- |
1000 |
|
- |
| 9(Insulating Materials) |
- |
0 |
|
- |
| 8(Height of the Fan) |
- |
1000 |
|
- |
| 7(Finish) |
- |
0 |
|
- |
| 6(Design and General
Construction) |
- |
0 |
|
- |
| 5(Rated Frequency) |
- |
0 |
|
- |
| 4(Rated Voltage) |
- |
0 |
|
- |
| 3(Sizes, Speed & Types) |
- |
0 |
|
- |
| 18( Tolerances on rating) |
- |
0 |
|
- |
| 17(Performance Reqirement) |
- |
0 |
|
- |
| 16.14(Insulation-resistance ) |
- |
1000 |
|
- |
| 16.13(Flash Test) |
- |
0 |
|
- |
| 16.12(Measurement of Fan Speed) |
- |
1000 |
|
- |
| 16.11(Electrical Input Test) |
- |
1000 |
|
- |
| 16.1(Earthing Continuity Test) |
- |
1000 |
|
- |
| 16.9(High Voltage) |
- |
1000 |
|
- |
| 16.8(AC Leakage Test) |
- |
2000 |
|
- |
| 16.7(Power Factor) |
- |
500 |
|
- |
| 16.6(Mechanical Endurance Test (for
Regulators only)) |
- |
3000 |
|
- |
| 16.5(Cord grip test) |
- |
2000 |
|
- |
| 16.4(Moisture Proofness Test (for
Regulators only)) |
- |
2000 |
|
- |
| 16.3(Temperature-rise) |
- |
1000 |
|
- |
| 16.2(Air Delivery Test) |
- |
10000 |
|
- |
| 15(Marking) |
- |
500 |
|
- |
| 14(Oscillating Mechanism) |
- |
0 |
|
- |
| 13(Silent Operation) |
- |
750 |
|
- |
| 12(Interchangeability) |
- |
500 |
|
- |
| 11(Starting) |
- |
750 |
|
- |
| 10(Speed Regulators) |
- |
1000 |
|
- |
| 9(Insulating Materials) |
- |
0 |
|
- |
| 8(Height of the Fan) |
- |
1000 |
|
- |
| 7(Finish) |
- |
0 |
|
- |
| 6(Design and General
Construction) |
- |
0 |
|
- |
| 5(Rated Frequency) |
- |
0 |
|
- |
| 4(Rated Voltage) |
- |
0 |
|
- |
| 3(Sizes, Speed & Types) |
- |
0 |
|
- |
|
31 Mar, 2028 |
- included w.e.f 18.03.2026 |
| 807 |
MORBI TEST HOUSE LLP
| 7195306
| IS 848 (2025) |
Synthetic Resin Adhesives for Plywood (Phenolic, Aminoplastic and Bio-Materials Based) - Specification ( Third Revision ) |
All |
7500 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| As per Clause 4 Table 1(TYPES) |
- |
100 |
|
- |
| As per Clause 6.6(SETTING TIMES AND CONDITIONS) |
- |
0 |
|
- |
| As per Clause 7.3.2 Table 1(i)(Cyclic Test For BWP Type) |
- |
2000 |
|
- |
| As per Clause 7.3.2 Table 1(ii)(Cyclic Test For BWR Type) |
- |
2000 |
|
- |
| As per Clause 7.3.2 Table 1(iii)(Cyclic Test For MR Type) |
- |
2000 |
|
- |
| As per Clause 7.4(Acidity And Alkalinity (pH)) |
- |
1500 |
|
- |
| As per Clause 9(Marking) |
- |
0 |
|
- |
|
02 Jan, 2029 |
- Included w.e.f 09.02.2026 |
| 808 |
Vimta labs Limited, Hyderabad
| 6102906
| IS 555 (1979) |
Specification for electric table type fans and regulators (Third Revision) |
- |
30000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 10.16(Creepage Distances and Clearances) |
- |
2000 |
|
- |
| 10.14(Cord Grip Test) |
- |
2000 |
|
- |
| 10.13, 7.4(Mechanical Endurance Test (for Regulators Only)) |
- |
3000 |
|
- |
| 10.12(Moisture Resistance Test) |
- |
2000 |
|
- |
| 10.11(Protection against Electric Shock) |
- |
2000 |
|
- |
| 10.1(Earthing Connection) |
- |
1000 |
|
- |
| 10.9(Fan Speed and Input) |
- |
2000 |
|
- |
| 10.8(Construction) |
- |
1000 |
|
- |
| 10.7(Insulation-Resistance Test (Shall follow Moisture Resistance Test Cl.10.12)) |
- |
1000 |
|
- |
| 10.6(High Voltage Test) |
- |
1000 |
|
- |
| 10.5(Leakage Current) |
- |
2000 |
|
- |
| 10.4(Temperature-Rise Test) |
- |
1000 |
|
- |
| 10.3(Air Delivery Test) |
- |
10000 |
|
- |
| 9.0(Marking) |
- |
0 |
|
- |
| 7.11(Oscillating Mechanism) |
- |
0 |
|
- |
| 7.9(Interchangeability) |
- |
0 |
|
- |
| 7.8(Speed Regulators) |
- |
0 |
|
- |
| 6.0(Design and General Construction) |
- |
0 |
|
- |
| 5.0(Rated Frequency) |
- |
0 |
|
- |
| 4.0(Rated Voltages) |
- |
0 |
|
- |
| 3.0(Size, Speed and Types) |
- |
0 |
|
- |
| 7.1(Protection Against Electric Shock) |
- |
0 |
|
- |
| 7.2(Electrical Insulation Under Normal Operating Conditions) |
- |
0 |
|
- |
| 7.3(Temperature-rise) |
- |
0 |
|
- |
| 7.5(Creepage Distances and Clearances) |
- |
0 |
|
- |
| 7.6(Finish) |
- |
0 |
|
- |
| 7.7(Insulating Materials) |
- |
0 |
|
- |
| 7.10(Oscillating Mechanism) |
- |
0 |
|
- |
| 8.1, 8.2(Air delivery and service value) |
- |
0 |
|
- |
| 10.13, 7.4(Mechanical Endurance Test (for Regulators Only)) |
- |
3000 |
|
- |
| 7.1(Protection Against Electric Shock) |
- |
0 |
|
- |
| 7.2(Electrical Insulation Under Normal Operating Conditions) |
- |
0 |
|
- |
| 7.3(Temperature-rise) |
- |
0 |
|
- |
| 7.5(Creepage Distances and Clearances) |
- |
0 |
|
- |
| 7.6(Finish) |
- |
0 |
|
- |
| 7.7(Insulating Materials) |
- |
0 |
|
- |
| 7.10(Oscillating Mechanism) |
- |
0 |
|
- |
| 8.1, 8.2(Air delivery and service value) |
- |
0 |
|
- |
|
31 Mar, 2028 |
- included w.e.f 16.02.2026 |
| 809 |
LPG Equipment Research Centre (LERC), Bengaluru
| 6141034
| IS/ISO 22702 (2018) |
Utility lighters Safety specifications First Revision |
- |
14000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4.1(Flame generation) |
- |
500 |
|
- |
| 4.2(Flame heights) |
- |
500 |
|
- |
| 4.3(Flame- height adjustment) |
- |
500 |
|
- |
| 4.4("Resistance to Spitting or
Sputtering and flaring") |
- |
500 |
|
- |
| 4.5(Flame extinction) |
- |
500 |
|
- |
| 4.6(Volumetric Displacement) |
- |
500 |
|
- |
| 5.2(Resistance to dropping) |
- |
500 |
|
- |
| 5.3(Resistance to elevated temperature) |
- |
3500 |
|
- |
| 5.4(Burning behavior) |
- |
500 |
|
- |
| 5.5(Resistance to continuous burn) |
- |
1000 |
|
- |
| 5.6(Resistance to cyclic burn) |
- |
1000 |
|
- |
| 5.7(External Finish) |
- |
500 |
|
- |
| 5.8(Compatibility with fuel) |
- |
500 |
|
- |
| 5.9(Resistance to internal pressure) |
- |
3000 |
|
- |
| 6(Refilling Test) |
- |
500 |
|
- |
|
- |
- Included w.e.f 09.02.2026 |
| 810 |
INDIAN RUBBER MATERIALS RESEARCH INSTITUTE (IRMRI)
| 7119305
| IS 10908 (2023) |
FLEXIBLE RUBBER TUBING FOR LIQUEFIED PETROLEUM GAS SPECIFICATION Second Revision |
- |
16300 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4.1(The materials used in the manufacture of tubing shall be homogeneous and shall be resistant to outdoor exposure.) |
- |
100 |
|
- |
| 4.1(The tubing made out of this material shall be green in colour and shall be supplied normally in cut lengths or in rolls of running length) |
- |
100 |
|
- |
| 4.1("when supplied in cut lengths, the pieces
shall be of minimum 1.0 m to maximum of 1.5 m in length.
") |
- |
100 |
|
- |
| 4.2(The walls shall be seamless and free from all visible defects, such as lumps, blow-holes, cracks etc and the bore shall be clean and free from loose particles which might be carried forward by the gas.) |
- |
100 |
|
- |
| 4.3.1(The tubing when supplied in 6.4 mm inside diameter; the tolerance as per table-1) |
- |
200 |
|
- |
| 4.3.1(The tubing when supplied in 7.00 mm inside diameter; the tolerance as per table-1) |
- |
200 |
|
- |
| 4.3.2(It shall comply with thickness as given in Table 1, when measured according to IS 443 (Part 8). The readings shall be taken on a set of six test pieces cut from different sample sections.(For Wall thickness 3.20 mm)) |
- |
200 |
|
- |
| 4.3.2(It shall comply with thickness as given in Table 1, when measured according to IS 443 (Part 8). The readings shall be taken on a set of six test pieces cut from different sample sections.(For Wall thickness 3.50 mm)) |
- |
200 |
|
- |
| 4.4.1(When tested in accordance with the method given in Annex B, the tubing shall fit over the standard and oversize metal nozzle shown in Fig. 1, 2 and 3.) |
- |
1300 |
|
- |
| 4.4.2("When tested in accordance with the method given in Annex B, the tubing shall remain attached to both nozzles throughout the test period.
") |
- |
1300 |
|
- |
| 4.5(When immersed in water for 5 min under an internal air pressure of 0.25 MPa or 250 kPa (2.5 bar), the increase in the outside diameter or the tubing shall not be more than 15 percent.) |
- |
1000 |
|
- |
| 4.12("When tested in accordance with the method
described in Annex F, the tubing shall not burn to either of the outer marks within the test period of 45 s") |
- |
1000 |
|
- |
| 4.11("When tested in accordance with the method
described in Annex E, the slit tube shall not show any breakage on surface or cracks or defects.") |
- |
3000 |
|
- |
| 4.10(When tested in accordance with Annex D, the npentane absorbed shall not exceed 15 percent of the initial mass of the tubing and the amount of npentane extractable matter shall not exceed 10 percent of the initial mass of tubing.) |
- |
2000 |
|
- |
| 4.9(60 cm long tubing shall be subjected to a crushing force of 350 N applied on the middle of the tubing evenly over a length of 25 mm for 5 minutes, and 30 min after removal of the force it shall not show any deformation or collapse, nor shall it leak when subjected to an internal air pressure of 250 kPa) |
- |
1000 |
|
- |
| 4.8.2(The tubing shall be so flexible that it will make contact with a cylindrical former of radius 68 mm for at least 110° of its circumference when the immersed tubing is placed over the former and a mass of 1.6 kg is attached to each end.) |
- |
1000 |
|
- |
| 4.8.1("The tubing shall be immersed for 72 h in liquid pentane and then conditioned at room temperature for 24 h, after which it shall be tested in accordance with the method prescribed in Annex C, the gas pressure shown on the manometer shall not drop by
more than 1 kPa") |
- |
1000 |
|
- |
| 4.7("The flexible tubing or suitable portion of the tubing shall be subjected to accelerated ageing at a temperature of 100 °C for 72 h in accordance with the normal method prescribed in IS 3400 (Part 4). It shall not show a change of + 10° A of its original
shore hardness value (see 4.6) after accelerated ageing") |
- |
1000 |
|
- |
| 4.6(The hardness on the flat surface of the cut/slit tubing shall be measured as prescribed in IS 3400 (Part 2/Sec 4), the shore hardness shall be 60 ± 5°A.) |
- |
500 |
|
- |
| 4.5(When immersed in water for 5 min under an internal air pressure of 0.25 MPa or 250 kPa (2.5 bar), there shall be no sign of leakage in the tubing. Also the same shall not burst when the pressure is increased to 0.5 MPa or 500 kPa (5 bar), The test shall be carried out on a length of 60 cm.) |
- |
1000 |
|
- |
|
- |
- included w.e.f 17.02.2026 |