8761 |
UL INDIA PRIVATE LIMITED
| IS 16169 (2014) |
Utility - Interconnected photovoltaic inverters - Test procedure of islanding prevention measures |
Photovoltaic (PV) Inverter(s) |
-
|
400000 View breakup
Rs.4,00,000/-
10% discount to BIS
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
6 to 6.2, (Elec)(Test for single or multi-phase inverter to Pass/fail criteria) |
- |
320000 |
|
- |
|
Complete
|
|
12 May, 2027 |
- - |
8762 |
BLUESKY LAB LLP
| IS 302 : Part 2 : Sec 14 (2009) |
Safety of household and similar electrical appliances: Part 2 particular requirements: Sec 14 electric kitchen machines (First Revision) |
- |
-
|
14700 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
6(Classification- IS 302-1 ) |
- |
200 |
|
10% discount offered to BIS |
7.1(Marking- IS 302-1) |
- |
100 |
|
10% discount offered to BIS |
7.3(Marking- IS 302-1) |
- |
100 |
|
10% discount offered to BIS |
7.4(Marking- IS 302-1) |
- |
100 |
|
10% discount offered to BIS |
7.6(Marking- IS 302-1) |
- |
100 |
|
10% discount offered to BIS |
7.7(Marking- IS 302-1) |
- |
100 |
|
10% discount offered to BIS |
7.8(Marking- IS 302-1) |
- |
100 |
|
10% discount offered to BIS |
7.11(Marking- IS 302-1) |
- |
100 |
|
10% discount offered to BIS |
7.12(Marking- IS 302-1) |
- |
100 |
|
10% discount offered to BIS |
7.13(Marking- IS 302-1) |
- |
100 |
|
10% discount offered to BIS |
7.14(Marking- IS 302-1) |
- |
500 |
|
10% discount offered to BIS |
7.15(Marking- IS 302-1) |
- |
100 |
|
10% discount offered to BIS |
8( Protection Against Electric Shock, IS 302-1) |
- |
1000 |
|
10% discount offered to BIS |
7.101(Marking) |
- |
0 |
|
10% discount offered to BIS |
10(Power Input and Current, IS 302-1) |
- |
1000 |
|
10% discount offered to BIS |
11(Heating, IS 302-1) |
- |
1200 |
|
10% discount offered to BIS |
13(Electrical Insulation and Leakage Current at Operating Temperature: Leakage current, IS 302-1) |
- |
700 |
|
10% discount offered to BIS |
13(Electrical Insulation and Leakage Current at Operating Temperature: High Voltage, IS 302-1) |
- |
700 |
|
10% discount offered to BIS |
14(Transient Over Voltages, IS 302-1) |
- |
1200 |
|
10% discount offered to BIS |
15(Moisture Resistance, IS 302-1) |
- |
2500 |
|
10% discount offered to BIS |
16(Electrical Insulation and Leakage Current at Operating Temperature: Leakage current, IS 302-1) |
- |
1000 |
|
10% discount offered to BIS |
17(Overload protection of Transformers and Associated Circuits, IS 302-1) |
- |
700 |
|
10% discount offered to BIS |
19.1(Abnormal Operation, IS 302-1) |
- |
1000 |
|
10% discount offered to BIS |
19.7(Abnormal Operation, IS 302-1) |
- |
500 |
|
10% discount offered to BIS |
19.8(Abnormal Operation, IS 302-1) |
- |
500 |
|
10% discount offered to BIS |
19.9(Abnormal Operation, IS 302-1) |
- |
500 |
|
10% discount offered to BIS |
19.101(Abnormal Operation) |
- |
200 |
|
10% discount offered to BIS |
20.1(Stability & Mechanical Hazards, IS 302-1) |
- |
500 |
|
10% discount offered to BIS |
20.2(Stability & Mechanical Hazards, IS 302-1) |
- |
500 |
|
10% discount offered to BIS |
20.101(Stability & Mechanical Hazards) |
- |
200 |
|
10% discount offered to BIS |
20.102(Stability & Mechanical Hazards) |
- |
200 |
|
10% discount offered to BIS |
20.103(Stability & Mechanical Hazards) |
- |
200 |
|
10% discount offered to BIS |
20.104(Stability & Mechanical Hazards) |
- |
200 |
|
10% discount offered to BIS |
20.105(Stability & Mechanical Hazards) |
- |
100 |
|
10% discount offered to BIS |
20.106(Stability & Mechanical Hazards) |
- |
100 |
|
10% discount offered to BIS |
20.107(Stability & Mechanical Hazards) |
- |
100 |
|
10% discount offered to BIS |
20.108(Stability & Mechanical Hazards) |
- |
200 |
|
10% discount offered to BIS |
20.109(Stability & Mechanical Hazards) |
- |
200 |
|
10% discount offered to BIS |
20.110(Stability & Mechanical Hazards) |
- |
200 |
|
10% discount offered to BIS |
20.111(Stability & Mechanical Hazards) |
- |
200 |
|
10% discount offered to BIS |
20.112(Stability & Mechanical Hazards) |
- |
200 |
|
10% discount offered to BIS |
20.113(Stability & Mechanical Hazards) |
- |
200 |
|
10% discount offered to BIS |
20.114(Stability & Mechanical Hazards) |
- |
200 |
|
10% discount offered to BIS |
20.115(Stability & Mechanical Hazards) |
- |
200 |
|
10% discount offered to BIS |
20.116(Stability & Mechanical Hazards) |
- |
200 |
|
10% discount offered to BIS |
21.1(Mechanical Strength, IS 302-1) |
- |
500 |
|
10% discount offered to BIS |
21.2(Mechanical Strength, IS 302-1) |
- |
500 |
|
10% discount offered to BIS |
22(Construction, IS 302-1) |
- |
1000 |
|
10% discount offered to BIS |
22.101(Construction) |
- |
200 |
|
10% discount offered to BIS |
22.102(Construction) |
- |
200 |
|
10% discount offered to BIS |
23.1(Internal Wiring, IS 302-1) |
- |
600 |
|
10% discount offered to BIS |
23.2(Internal Wiring, IS 302-1) |
- |
400 |
|
10% discount offered to BIS |
23.3(Internal Wiring, IS 302-1) |
- |
400 |
|
10% discount offered to BIS |
23.4(Internal Wiring, IS 302-1) |
- |
400 |
|
10% discount offered to BIS |
23.5(Internal Wiring, IS 302-1) |
- |
400 |
|
10% discount offered to BIS |
23.6(Internal Wiring, IS 302-1) |
- |
400 |
|
10% discount offered to BIS |
23.7(Internal Wiring, IS 302-1) |
- |
400 |
|
10% discount offered to BIS |
23.8(Internal Wiring, IS 302-1) |
- |
400 |
|
10% discount offered to BIS |
23.9(Internal Wiring, IS 302-1) |
- |
400 |
|
10% discount offered to BIS |
23.10(Internal Wiring, IS 302-1) |
- |
400 |
|
10% discount offered to BIS |
24.1(Components, IS 302-1) |
- |
1000 |
|
10% discount offered to BIS |
24.2(Components, IS 302-1) |
- |
1000 |
|
10% discount offered to BIS |
24.5(Components, IS 302-1) |
- |
500 |
|
10% discount offered to BIS |
24.6(Components, IS 302-1) |
- |
400 |
|
10% discount offered to BIS |
25.1(Supply Connection and External Flexible Cords, IS 302-1) |
- |
500 |
|
10% discount offered to BIS |
25.5(Supply Connection and External Flexible Cords, IS 302-1) |
- |
400 |
|
10% discount offered to BIS |
25.6(Supply Connection and External Flexible Cords, IS 302-1) |
- |
400 |
|
10% discount offered to BIS |
25.7(Supply Connection and External Flexible Cords, IS 302-1) |
- |
400 |
|
10% discount offered to BIS |
25.8(Supply Connection and External Flexible Cords, IS 302-1) |
- |
400 |
|
10% discount offered to BIS |
26.9(Supply Connection and External Flexible Cords, IS 302-1) |
- |
400 |
|
10% discount offered to BIS |
25.1(Supply Connection and External Flexible Cords, IS 302-1) |
- |
400 |
|
10% discount offered to BIS |
25.11(Supply Connection and External Flexible Cords, IS 302-1) |
- |
400 |
|
10% discount offered to BIS |
25.12(Supply Connection and External Flexible Cords, IS 302-1) |
- |
400 |
|
10% discount offered to BIS |
25.13(Supply Connection and External Flexible Cords, IS 302-1) |
- |
400 |
|
10% discount offered to BIS |
25.14(Supply Connection and External Flexible Cords, IS 302-1) |
- |
400 |
|
10% discount offered to BIS |
25.15(Supply Connection and External Flexible Cords, IS 302-1) |
- |
400 |
|
10% discount offered to BIS |
25.16(Supply Connection and External Flexible Cords, IS 302-1) |
- |
400 |
|
10% discount offered to BIS |
25.17(Supply Connection and External Flexible Cords, IS 302-1) |
- |
400 |
|
10% discount offered to BIS |
25.18(Supply Connection and External Flexible Cords, IS 302-1) |
- |
400 |
|
10% discount offered to BIS |
25.19(Supply Connection and External Flexible Cords, IS 302-1) |
- |
400 |
|
10% discount offered to BIS |
25.2(Supply Connection and External Flexible Cords, IS 302-1) |
- |
400 |
|
10% discount offered to BIS |
25.21(Supply Connection and External Flexible Cords, IS 302-1) |
- |
200 |
|
10% discount offered to BIS |
25.22(Supply Connection and External Flexible Cords, IS 302-1) |
- |
200 |
|
10% discount offered to BIS |
26(Terminals for External Conductors, IS 302-1) |
- |
500 |
|
10% discount offered to BIS |
27(Provision for Earthing, IS 302-1) |
- |
400 |
|
10% discount offered to BIS |
27.2(Provision for Earthing, IS 302-1) |
- |
600 |
|
10% discount offered to BIS |
27.3(Provision for Earthing, IS 302-1) |
- |
400 |
|
10% discount offered to BIS |
27.4(Provision for Earthing, IS 302-1) |
- |
400 |
|
10% discount offered to BIS |
27.5(Provision for Earthing, IS 302-1) |
- |
500 |
|
10% discount offered to BIS |
28(Screws & Connections, IS 302-1) |
- |
500 |
|
10% discount offered to BIS |
29.1(Clearances, Creepage distances and Solid Insulation, IS 302-1) |
- |
600 |
|
10% discount offered to BIS |
29.2(Clearances, Creepage distances and Solid Insulation, IS 302-1) |
- |
600 |
|
10% discount offered to BIS |
30.1(Resistance to Heat and Fire, IS 302-1) |
- |
1000 |
|
10% discount offered to BIS |
30.2(Resistance to Heat and Fire, IS 302-1) |
- |
1000 |
|
10% discount offered to BIS |
31(Resistance of Rusting, IS 302-1) |
- |
1000 |
|
10% discount offered to BIS |
19.11.4.4(Surge immunity test) |
- |
2000 |
|
10% discount offered to BIS |
|
Complete
|
|
22 May, 2028 |
- EMI/EMC tests (Electrostatic discharges, radiant fields, fast transient bursts, voltage surges, injected current, voltage dip and interruption, mains signals) (Cl.19.11.4.1 to 19.11.4.7) |
8763 |
BLUESKY LAB LLP
| IS 302 : Part 1 (2008) |
Safety of household and similar electrical appliances: Part 1 general requirements (Sixth Revision) |
- |
-
|
42000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
7(Marking and instructions) |
- |
1000 |
|
10% discount offered to BIS |
8.1.1(Protection against live parts in all positions) |
- |
200 |
|
10% discount offered to BIS |
8.1.2(Protection against live parts in openings) |
- |
200 |
|
10% discount offered to BIS |
8.1.3(Protection against live parts in visible glowing heating elements) |
- |
300 |
|
10% discount offered to BIS |
8.1.4(Protection against live parts against protective impedance) |
- |
200 |
|
10% discount offered to BIS |
10.1(Power input) |
- |
800 |
|
10% discount offered to BIS |
10.2(Current input) |
- |
800 |
|
10% discount offered to BIS |
11.1(General) |
- |
800 |
|
10% discount offered to BIS |
11.2(General) |
- |
1000 |
|
10% discount offered to BIS |
11.3(Heating) |
- |
1000 |
|
10% discount offered to BIS |
13.1(General) |
- |
100 |
|
10% discount offered to BIS |
13.2(Leakage current at operating temperature) |
- |
1200 |
|
10% discount offered to BIS |
13.3(Electric Strength at operating temperature) |
- |
1200 |
|
10% discount offered to BIS |
14(Transient Over Voltages) |
- |
1400 |
|
10% discount offered to BIS |
15.0(General) |
- |
200 |
|
10% discount offered to BIS |
15.1(Ingress Protection test other than IPX0 (IP test)) |
- |
2000 |
|
10% discount offered to BIS |
15.2(Spillage Test) |
- |
500 |
|
10% discount offered to BIS |
15.3(Humidity Test) |
- |
1500 |
|
10% discount offered to BIS |
16.0(General) |
- |
100 |
|
10% discount offered to BIS |
16.1(General) |
- |
100 |
|
10% discount offered to BIS |
16.2(Leakage Current (after Clause 15)) |
- |
1000 |
|
10% discount offered to BIS |
16.3(Electric Strength (after clause 15 and 16.2)) |
- |
1000 |
|
10% discount offered to BIS |
17(Over Load Protection of Transformers and associated circuits) |
- |
1300 |
|
10% discount offered to BIS |
19(Abnormal Operation) |
- |
2000 |
|
10% discount offered to BIS |
20(Stability test) |
- |
1500 |
|
10% discount offered to BIS |
21(Mechanical Strength Test) |
- |
1850 |
|
10% discount offered to BIS |
22(Construction verification related test) |
- |
5000 |
|
10% discount offered to BIS |
23(General) |
- |
1000 |
|
10% discount offered to BIS |
24(Components) |
- |
1300 |
|
10% discount offered to BIS |
25(Supply connection and external flexible cords) |
- |
1600 |
|
10% discount offered to BIS |
26(Terminals for external conductors) |
- |
1000 |
|
10% discount offered to BIS |
27(Provision for earthing) |
- |
2100 |
|
10% discount offered to BIS |
28(Screw test and connections) |
- |
800 |
|
10% discount offered to BIS |
29(clearance, creepage distances and solid insulation) |
- |
2500 |
|
10% discount offered to BIS |
30.1(Ball pressure test) |
- |
2000 |
|
10% discount offered to BIS |
30.2(Glow Wire Test) |
- |
2000 |
|
10% discount offered to BIS |
30.2(Needle Flame Test) |
- |
2000 |
|
10% discount offered to BIS |
31(Resistance to Rusting) |
- |
2100 |
|
10% discount offered to BIS |
19.11.4.4(Surge immunity test) |
- |
2000 |
|
10% discount offered to BIS |
|
Complete
|
|
22 May, 2028 |
view Scope file Exclusions: EMI/EMC (ESD, Radiated fields, EFT Surge, Conducted Immunity, Dips & Interruptions,
Harmonics &Interharmonics) (Cl.19.11.4.1 to 19.11.4.7), Capacitor Test (Cl.
24.1.1), Switching Cycle Operation Test (Cl. 24.1.3), Automatic Control Cycle Operation
Test (Cl. 24.1.4), Appliance Coupler and Interconnection (Cl. 24.1.5), Lamp Holder
Test (Cl. 24.1.6), Capacitor in Auxillary Winding of Motor Test (Cl. 24.5) and
Motors Basic Insulation Test (Cl. 24.6), Components (Cl.24), ], Radiation, Toxicity & Similar Hazards (cl.32) |
8764 |
CIPET, Hyderabad
| IS 14856 (2000) |
Glass fibre reinforced plastic (GRP) panel type door shutters for internal use - Specification |
- |
-
|
11181 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
6.1(CONSTRUCTION/ FABRICATION) |
- |
1000 |
|
- |
|
Complete
|
|
23 Feb, 2027 |
- - |
8765 |
BLUESKY LAB LLP
| IS 302 : Part 2 : Sec 15 (2009) |
Safety of household and similar electrical appliances: Part 2 particular requirements: Sec 15 appliances for heating liquids (First Revision) |
- |
-
|
16838 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
6.0(Classification) |
- |
500 |
|
10% discount offered to BIS |
7(Marking and instructions) |
- |
1000 |
|
10% discount offered to BIS |
8(Protection against live parts) |
- |
1000 |
|
10% discount offered to BIS |
10(POWER INPUT AND CURRENT) |
- |
1500 |
|
10% discount offered to BIS |
11(HEATING) |
- |
2800 |
|
10% discount offered to BIS |
13(LEAKAGE CURRENT AND ELECTRIC STRENGTH AT OPERATING TEMPERATURE) |
- |
2500 |
|
10% discount offered to BIS |
14(TRANSIENT OVERVOLTAGES) |
- |
1400 |
|
10% discount offered to BIS |
15(MOISTURE RESISTANCE) |
- |
4200 |
|
10% discount offered to BIS |
16(LEAKAGE CURRENT AND ELECTRIC STRENGTH) |
- |
2200 |
|
10% discount offered to BIS |
17(OVERLOAD PROTECTION OF TRANSFORMERS AND ASSOCIATED CIRCUITS) |
- |
1300 |
|
10% discount offered to BIS |
19(ABNORMAL OPERATION) |
- |
2000 |
|
10% discount offered to BIS |
20(STABILITY AND MECHANICAL HAZARDS) |
- |
1500 |
|
10% discount offered to BIS |
21(MECHANICAL STRENGTH) |
- |
1850 |
|
10% discount offered to BIS |
22(CONSTRUCTION) |
- |
5000 |
|
10% discount offered to BIS |
23(INTERNAL WIRING) |
- |
1000 |
|
10% discount offered to BIS |
24(COMPONENTS) |
- |
1300 |
|
10% discount offered to BIS |
25(SUPPLY CONNECTION AND EXTERNAL FLEXIBLE CORDS) |
- |
1600 |
|
10% discount offered to BIS |
26(TERMINALS FOR EXTERNAL CONDUCTORS) |
- |
1000 |
|
10% discount offered to BIS |
27(PROVISION FOR EARTHING) |
- |
2100 |
|
10% discount offered to BIS |
28(SCREWS AND CONNECTIONS) |
- |
800 |
|
10% discount offered to BIS |
29(CLEARANCES, CREEPAGE DISTANCES AND SOLID INSULATION) |
- |
2550 |
|
10% discount offered to BIS |
30(RESISTANCE TO HEAT AND FIRE) |
- |
6000 |
|
10% discount offered to BIS |
31(RESISTANCE TO RUSTING) |
- |
2100 |
|
10% discount offered to BIS |
19.11.4.4(Surge immunity test) |
- |
2000 |
|
10% discount offered to BIS |
|
Complete
|
|
22 May, 2028 |
- Restricted to Non Pressure Rice cooker only. EMI/EMC tests (electrostatic Discharges,
Radiant Fields, Fast Transient burst, Voltage surges, Injected current, voltage dips & Interruptions, Mains signals) [cl.19.11.4.1 to Cl.19.11.4.7], Radiation, Toxicity & Similar Hazards (cl.32),
Components (Cl.24), |
8766 |
BIS, Western Regional Laboratory (WRL)
| IS 13489 (2000) |
Textiles – Bed mattress – Specification (first revision) |
- |
-
|
- View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
5.1 a) (Length) |
- |
|
|
|
5.1 b) (Width) |
- |
|
|
|
5.1 c) (Thickness) |
- |
|
|
|
3 (TYPES) |
- |
|
|
|
4
Table 1 (MATERIALS) |
- |
|
|
|
4
Table 1 i)a)
IS 175 (Case) |
- |
|
|
|
4
Table 1 ii) a)
1S8391 (Cushioning) |
- |
|
|
|
4
Table 1 ii) b)
IS 1741 (Cushioning) |
- |
|
|
|
4
Table 1 ii) c)
IS 7933 (Cushioning) |
- |
|
|
|
4
Table 1 iii) a)
IS 1920 (Piping) |
- |
|
|
|
4
Table 1 ii) b)
IS 1741 (Cushioning) |
- |
|
|
|
4
Table 1 ii) c)
IS 7933 (Cushioning) |
- |
|
|
|
4
Table 1 iii) a)
IS 1920 (Piping) |
- |
|
|
|
4
Table 1 iii) b)
IS 3252 (Piping) |
- |
|
|
|
4
Table 1 iv)
IS 1895 (Tying tapes) |
- |
|
|
|
5.1
Fig. l (Type 1 Mattress) |
- |
|
|
|
5.2 (Type 2 Mattress) |
- |
|
|
|
5.2 a) (Length) |
- |
|
|
|
5.2 b) (Width) |
- |
|
|
|
5.2 c) (Thickness) |
- |
|
|
|
6.1 (MANUFACTURE) |
- |
|
|
|
6.2 (MANUFACTURE) |
- |
|
|
|
6.3 (MANUFACTURE) |
- |
|
|
|
6.4 (MANUFACTURE) |
- |
|
|
|
6.5 (MANUFACTURE) |
- |
|
|
|
3 (TYPES) |
- |
|
|
|
cl. 7.2 (BIS certification marking) |
- |
|
|
|
cl. 7.1 (marking) |
- |
|
|
|
|
Partial
|
|
- |
- - |
8767 |
BIS, Western Regional Laboratory (WRL)
| IS 9873 : Part 4 (2017) |
Safety of toys: Part 4 swings, slides and similar activity toys for indoor and outdoor family domestic use |
- |
-
|
Rs.5475/- View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
4.1.1 and 6.2.1 ( Strength of toys other than swings) |
- |
|
|
|
4.1.2 and A.4.1.2 (Maximum height) |
- |
|
|
|
4.1.3 and A.4.1.3 (Corners and edges on moving parts) |
- |
|
|
|
4.1.4.1 and 6.7.1 and Fig.6 (Protruding parts) |
- |
|
|
|
4.1.4.2 and 6.7.1 and
Fig.7 (All protrusions) |
- |
|
|
|
4.1.4.3 and 6.7.1 and
Fig.8 (Upright protrusions) |
- |
|
|
|
4.1.4.4 and 6.7.2 (Motion rides) |
- |
|
|
|
4.1.4.5 and 6.7.1.2 and Fig.9 (Slides) |
- |
|
|
|
4.1.4.5 (Slides) |
- |
|
|
|
4.1.5 and A.4.1.5. (Climbing and swinging ropes, chains and cables) |
- |
|
|
|
4.1.6 (Open tubing IS 9873 -1 / ISO 8124-1.) |
- |
|
|
|
4.2 and A.4.2. (Barriers-Barriers for platforms from 760 mm to 1 000 mm above the ground) |
- |
|
|
|
4.2 and A.4.2. (Barriers-Barriers for platforms greater than 1 000 mm and up to 1 830 mm above the ground) |
- |
|
|
|
4.2 and A.4.2. (Barriers for platforms more than 1 830 mm above the ground) |
- |
|
|
|
4.2 and A.4.2. (Barriers for platforms from 760 mm to 1 000 mm above the ground shall have a maximum vertical opening of 610 mm between the lowermost member of the barrier and the platform that it surrounds.) |
- |
|
|
|
4.2 and A.4.2. (Barriers for platforms more than 1 000 mm above the ground shall be designed to minimize the likelihood of climbing. Openings within these barriers or between the barrier and the platform surface shall not permit the passage of the torso probe defined in 6.5.1) |
- |
|
|
|
4.2 and A.4.2. and 4.6.2 and 4.6.3 (For barriers with an uneven top design) |
- |
|
|
|
4.3 (Rung ladders, stepladders and stairways) |
- |
|
|
|
4.3 a and Fig.10 (The rung or tread shall have a substantial horizontal stepping surface with a lateral width of 240 mm or more) |
- |
|
|
|
4.3 b and Fig.10 (The distance between the upper surface of the rungs or treads on rung ladders or stepladders shall not be more than 310 mm and on stairways not more 230 mm when measured vertically in accordance with Figure 10.) |
- |
|
|
|
4.3 c (The surface of the tread shall not be slippery) |
- |
|
|
|
4.3 d (The diameter or cross-sectional dimension of the rungs on rung ladders) |
- |
|
|
|
4.3.e (The depth of treads on stepladders with closed risers or stairways) |
- |
|
|
|
4.3 f (The inclination of stairways) |
- |
|
|
|
4.3 f (The inclination of stepladders) |
- |
|
|
|
4.3 f (The inclination of rung ladders) |
- |
|
|
|
4.3 g (Stairways and stepladders with a height of 1 200 mm or more above the ground shall be provided with a means of continuous hand support from a height of 760 mm) |
- |
|
|
|
4.3 g (A means of continuous hand support from a height of 760 mm) |
- |
|
|
|
4.4.1 (Head and neck entrapment) |
- |
|
|
|
4.4.2 (Entrapment of clothing and hair) |
- |
|
|
|
4.4.3 (Entrapment of feet) |
- |
|
|
|
4.4.4 (Entrapment of fingers) |
- |
|
|
|
4.5.1 (Stability of activity toys other than slides, swings and toys with crossbeams - General) |
- |
|
|
|
4.5.2 (Stability of activity toys with a free height of fall of 600 mm or less) |
- |
|
|
|
4.5.3 (Stability of activity toys with a free height of fall of more than 600 mm) |
- |
|
|
|
4.6.1 and A.4.6. (Stability of slides) |
- |
|
|
|
4.6.2 a and A.4.6. (Retaining sides for slides -For slides with a height of more than 1 000 mm above the ground, the height, h, of the retaining sides shall be 100 mm or more) |
- |
|
|
|
4.6.2 b and A.4.6. (Retaining sides for slides - For slides with a height of 1 000 mm or less above the ground, the height, h, of the retaining sides shall be 50 mm or more.) |
- |
|
|
|
4.6.3 a and A.4.6. (Starting, sliding and run-out section on slides -The starting section for slides with a height of 1 000 mm or less above the ground shall have) |
- |
|
|
|
4.6.3 a and A.4.6. (Starting, sliding and run-out section on slides -The starting section for slides with a height of 1 000 mm or less above the ground shall have) |
- |
|
|
|
4.6.3 a and A.4.6. (Starting, sliding and run-out section on slides -The starting section for slides with a height of 1 000 mm or less above the ground shall have) |
- |
|
|
|
4.6.3 b and A.4.6. (Starting, sliding and run-out section on slides-The starting section for slides with a height of more than 1 000 mm above the ground shall have) |
- |
|
|
|
4.6.3 b and A.4.6. (Starting, sliding and run-out section on slides-The starting section for slides with a height of more than 1 000 mm above the ground shall have) |
- |
|
|
|
4.6.3 b and A.4.6. (Starting, sliding and run-out section on slides-The starting section for slides with a height of more than 1 000 mm above the ground shall have) |
- |
|
|
|
4.6.3 c and A.4.6. (Starting, sliding and run-out section on slides) |
- |
|
|
|
4.6.3 d and A.4.6. (The angle of inclination to the horizontal of the sliding section) |
- |
|
|
|
4.6.3 e and A.4.6. (The run-out section for the slide) |
- |
|
|
|
4.6.3 e and A.4.6. (The run-out section for the slide) |
- |
|
|
|
4.6.3 e and A.4.6. (The run-out section for the slide) |
- |
|
|
|
4.6.3 f and A.4.6. (The finishing end of the run-out section shall have a radius of 25 mm or more through at least 90°) |
- |
|
|
|
4.6.4 and A.4.6. (Roller slides) |
- |
|
|
|
4.6.4 and A.4.6. (Roller slides) |
- |
|
|
|
4.6.4 and A.4.6. (Roller slides) |
- |
|
|
|
4.7.2 and A.4.7.2 (Strength of crossbeams, swing devices, suspension connectors and suspension couplings) |
- |
|
|
|
4.7.3.1 (Swings intended for children under 36 months) |
- |
|
|
|
4.7.3.1 (Swings intended for children under 36 months) |
- |
|
|
|
4.7.5 (Minimum clearance between swing elements, and similar equipment and adjacent structures) |
- |
|
|
|
4.7.5 (Free swinging elements) |
- |
|
|
|
4.7.5 (Elements excluding free swinging) |
- |
|
|
|
4.7.6 and A.4.7.6 (Lateral stability of swing elements - The minimum distance between the suspension points of a swing measured along the crossbeam) |
- |
|
|
|
4.7.7 (Minimum clearance between swing elements and the ground - The seating surface of swing elements with flexible means of suspension where the crossbeam height is greater than 1 200 mm) |
- |
|
|
|
4.7.7 (Minimum clearance between swing elements and the ground - The seating surface of swing elements with rigid means of suspension where the
crossbeam height is greater than 1 200 mm) |
- |
|
|
|
4.7.7 (Minimum clearance between swing elements and the ground - The seating surface of swing elements where the crossbeam height is 1 200 mm or less) |
- |
|
|
|
4.7.7 (Minimum clearance between swing elements and the ground - Footrests of swing elements) |
- |
|
|
|
4.7.8 a and A.4.7.8 (Suspension connectors and means of suspension) |
- |
|
|
|
4.7.8 b and A.4.7.8 (Suspension connectors and means of suspension) |
- |
|
|
|
4.7.8 c and A.4.7.8 (Ropes used as means of suspension - Diameter ) |
- |
|
|
|
4.7.8 d and A.4.7.8 (Straps and chains - Width) |
- |
|
|
|
4.7.8 d and A.4.7.8 (Accessible chains) |
- |
|
|
|
4.7.8 e and A.4.7.8 (Suspension connectors and means of suspension) |
- |
|
|
|
4.7.8 f and A.4.7.8 (Suspension connectors and means of suspension) |
- |
|
|
|
4.8 (Seesaws - The central point of the sitting or standing position of the seesaw shall not exceed a height) |
- |
|
|
|
4.8 (Seesaws - The sitting or standing position of the seesaw may swing out of the horizontal) |
- |
|
|
|
4.8 (Seesaws ) |
- |
|
|
|
4.9 (Carousels and rocking toys) |
- |
|
|
|
4.9 (Carousels and rocking toys) |
- |
|
|
|
4.10.1 and A.4.10 (Inflatable activity toys - General) |
- |
|
|
|
4.10.2 and A.4.10 (Inflatable activity toys - Anchorage) |
- |
|
|
|
4.10.2 and A.4.10 (Inflatable activity toys - Anchorage) |
- |
|
|
|
4.10.2 and A.4.10 (Inflatable activity toys - Anchorage) |
- |
|
|
|
4.10.2 and A.4.10 (Inflatable activity toys - Anchorage) |
- |
|
|
|
4.10.2 and A.4.10 (Inflatable activity toys - Anchorage) |
- |
|
|
|
4.10.3 and A.4.10 (Connection tubes for continuous inflation) |
- |
|
|
|
4.10.4.1 and A.4.10 (Containment - General) |
- |
|
|
|
4.10.4.1 and A.4.10 (Containment - General) |
- |
|
|
|
4.10.4.1 and A.4.10 (Containment - General) |
- |
|
|
|
4.10.4.1 and A.4.10 (Containment - General) |
- |
|
|
|
4.10.4.2 and A.4.10 (Platforms - Any platform intended for sitting or standing) |
- |
|
|
|
4.10.4.2 and A.4.10 (Containment walls with a minimum height ) |
- |
|
|
|
4.10.4.2 and A.4.10 (Permanently roofed Containment walls) |
- |
|
|
|
4.10.4.3 and A.4.10 (Slopes shall be treated as a platform.) |
- |
|
|
|
4.10.4.3 and A.4.10 (The first metre at the top of slopes) |
- |
|
|
|
4.10.4.3 and A.4.10 (The remaining length of slopes greater than 30° that are 760 mm or more above the ground shall be provided with containing walls with a minimum height of 900 mm.) |
- |
|
|
|
4.10.4.4 and A.4.10 (Safe collapse) |
- |
|
|
|
4.10.4.4 a and A.4.10 (When tested in accordance with 6.9 the minimum time taken for the test load to reach its lowest point ) |
- |
|
|
|
4.10.4.4 b and A.4.10 (the opening of any tunnel or squeeze point under any platform shall not be reduced in height by more than 50 % within 30 s.) |
- |
|
|
|
4.11.1 (Paddling pools - General) |
- |
|
|
|
4.11.2 (Edges, points, and small parts) |
- |
|
|
|
4.11.3 (Paddling pools with inflatable walls) |
- |
|
|
|
4.11.3 (Paddling pools with inflatable walls) |
- |
|
|
|
5.1 (Labelling) |
- |
|
|
|
5.2 (Assembly and installation instructions) |
- |
|
|
|
5.3 (Maintenance instructions) |
- |
|
|
|
5.4 (Warnings) |
- |
|
|
|
|
Partial
|
|
- |
- Test facilities are not available for the following:
1) Loads & pulling arrangements |
8768 |
BIS, Western Regional Laboratory (WRL)
| IS 9873 : Part 2 (2017) |
Safety of toys: Part 2 flammability (Third Revision) |
- |
-
|
Rs.2144/ View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
4.2.2-5.2 (Toys to be worn on the head-Beards, moustaches, wigs, etc. made from hair, pile, or material that behaves in a similar manner to hair (e.g. free-hanging ribbons, paper, cloth strands, or other flowing elements), which protrude 50 mm or more from the surface of the toy-Duration of the flame after the removal of the test flame) |
- |
|
|
|
4.2.2(a)-5.2 (Toys to be worn on the head-Test relating to Beards, moustaches, wigs, etc. made from hair, pile, or material that behaves in a similar manner to hair (e.g. free-hanging ribbons, paper, cloth strands, or other flowing elements), which protrude 50 mm or more from the surface of the toy- if ignition occurs, the maximum burnt length of hair, pile, or material that behaves in a similar manner when the initial length was 150 mm or more) |
- |
|
|
|
4.2.2(b)-5.2 (Toys to be worn on the head-Test relating to Beards, moustaches, wigs, etc. made from hair, pile, or material that behaves in a similar manner to hair (e.g. free-hanging ribbons, paper, cloth strands, or other flowing elements), which protrude 50 mm or more from the surface of the toy- if ignition occurs, the maximum burnt length of hair, pile, or material that behaves in a similar manner when the initial length was less than 150 mm) |
- |
|
|
|
4.2.3-5.3 (Toys to be worn on the head-Beards, moustaches, wigs, etc. made from hair, pile, or material that behaves in a similar manner to hair (e.g. free-hanging ribbons, paper, cloth strands, or other flowing elements), which protrude less than 50 mm and more than 5 mm from the surface of the toy-Duration of the flame after the removal of the test flame) |
- |
|
|
|
4.2.4-5.3 (Toys to be worn on the head-Full or partial moulded head masks-maximum distance between the upper edge of the burnt area and the point of application of the test flame) |
- |
|
|
|
4.2.5-5.4 (Toys to be worn on the head-Flowing elements of toys to be worn on the head (except those covered by 4.2.2 and 4.2.3), hoods, headdresses, etc. and masks not covered by 4.2.4 which partially or fully cover the head (e.g. fabric and cardboard masks, eye masks, face masks)-rate of spread of flame) |
- |
|
|
|
4.2.5-5.4 (Toys to be worn on the head-Flowing elements of toys to be worn on the head (except those covered by 4.2.2 and 4.2.3), hoods, headdresses, etc. and masks not covered by 4.2.4 which partially or fully cover the head (e.g. fabric and cardboard masks, eye masks, face masks)-Test relating to flowing elements of toys to be worn on the head (except those covered by 4.2.2 and 4.2.3), hoods, headdresses, etc. and masks not covered by 4.2.4 which partially or fully cover the head (e.g. fabric and cardboard masks, eye masks, face masks), toy disguise costumes and toys intended to be entered or worn by a child
) |
- |
|
|
|
4.3-5.4 (Toys to be worn on the head-Toy disguise costumes and toys intended to be worn by a child in play-rate of spread of flame) |
- |
|
|
|
4.3-5.4 (Toys to be worn on the head-Toy disguise costumes and toys intended to be worn by a child in play-Test relating to flowing elements of toys to be worn on the head (except those covered by 4.2.2 and 4.2.3), hoods, headdresses, etc. and masks not covered by 4.2.4 which partially or fully cover the head (e.g. fabric and cardboard masks, eye masks, face masks), toy disguise costumes and toys intended to be entered or worn by a child) |
- |
|
|
|
4.4-5.4 (Toys intended to be entered by a child-rate of spread of flame) |
- |
|
|
|
4.4-5.4 (Toys intended to be entered by a child-rate of spread of flame-Test relating to flowing elements of toys to be worn on the head (except those
covered by 4.2.2 and 4.2.3), hoods, headdresses, etc. and masks not covered by 4.2.4 which partially or fully cover the head (e.g. fabric and cardboard masks, eye masks, face masks), toy disguise costumes and toys intended to be entered or worn by a child) |
- |
|
|
|
4.4-5.4 (Toys intended to be entered by a child-rate of spread of flame-Test relating to flowing elements of toys to be worn on the head (except those
covered by 4.2.2 and 4.2.3), hoods, headdresses, etc. and masks not covered by 4.2.4 which partially or fully cover the head (e.g. fabric and cardboard masks, eye masks, face masks), toy disguise costumes and toys intended to be entered or worn by a child
) |
- |
|
|
|
4.5-5.5 (Soft-filled toys-rate of spread of flame ) |
- |
|
|
|
4.5-5.5 (Soft-filled toys-Test for soft-filled toys
) |
- |
|
|
|
|
Complete
|
|
- |
- - |
8769 |
BIS, Western Regional Laboratory (WRL)
| IS 9873 : Part 1 (2019) |
Safety of toys: Part 1 safety aspects related to mechanical and physical properties (Fourth Revision) |
- |
-
|
- View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
4.1 (Normal use) |
- |
|
|
|
|
Partial
|
|
- |
- Test facilities are not available for the following:
1) clause 4.29 Acoustic requirements, |
8770 |
SKC COMPLIANCE LAB PRIVATE LIMITED
| IS 13252 : Part 1 (2010) |
Information technology equipment - Safety: Part 1 general requirements (Second Revision) |
- |
-
|
120000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
1.7(Markings and instructions) |
- |
3500 |
|
10% discount for BIS |
1.6(Power interface .) |
- |
5000 |
|
10% discount for BIS |
2.1(Protection from electric shock and energy hazards) |
- |
7000 |
|
10% discount for BIS |
2.2(SELV circuits) |
- |
3000 |
|
10% discount for BIS |
2.3(TNV circuits) |
- |
3000 |
|
10% discount for BIS |
2.4(Limited current circuits) |
- |
1000 |
|
10% discount for BIS |
2.5(Limited power sources .) |
- |
1500 |
|
10% discount for BIS |
2.6(Provisions for earthing and bonding) |
- |
4500 |
|
10% discount for BIS |
2.7(Overcurrent and earth fault protection in primary circuits) |
- |
1000 |
|
10% discount for BIS |
2.8(Safety interlocks) |
- |
1000 |
|
10% discount for BIS |
2.9(Electrical insulation) |
- |
10000 |
|
10% discount for BIS |
2.10(Clearances, creepage distances and distances through insulation) |
- |
8000 |
|
10% discount for BIS |
3.1(General) |
- |
1000 |
|
10% discount for BIS |
3.2(Connection to a mains supply) |
- |
2000 |
|
10% discount for BIS |
3.3(Wiring terminals for connection of external conductors) |
- |
3000 |
|
10% discount for BIS |
3.5(Interconnection of equipment) |
- |
500 |
|
10% discount for BIS |
4.1(Stability) |
- |
2500 |
|
10% discount for BIS |
4.2(Mechanical strength) |
- |
8000 |
|
10% discount for BIS |
4.3(Design and construction) |
- |
5000 |
|
10% discount for BIS |
4.4(Protection against hazardous moving parts) |
- |
500 |
|
10% discount for BIS |
4.5(Thermal requirements) |
- |
6000 |
|
10% discount for BIS |
4.6(Openings in enclosures) |
- |
2000 |
|
10% discount for BIS |
4.7(Resistance to fire) |
- |
2500 |
|
10% discount for BIS |
5.1(Touch current and protective conductor curren) |
- |
2500 |
|
10% discount for BIS |
5.2(Electric strength) |
- |
3500 |
|
10% discount for BIS |
5.3(Abnormal operating and fault conditions) |
- |
4500 |
|
10% discount for BIS |
6.1(Protection of telecommunication network service persons, and users of other equipment connected to the network, from hazards in the equipment) |
- |
500 |
|
10% discount for BIS |
6.2(Protection of equipment users from overvoltages on networks telecommunication) |
- |
500 |
|
10% discount for BIS |
6.3(Protection of the telecommunication wiring system from overheating) |
- |
500 |
|
10% discount for BIS |
7.2(Protection of cable distribution system service persons, and users of other equipment connected to the system, from hazardous voltages in the equipment) |
- |
500 |
|
10% discount for BIS |
7.3(Protection of equipment users from overvoltages on the cable distribution system) |
- |
500 |
|
10% discount for BIS |
7.4(Insulation between primary circuits and cable distribution systems) |
- |
500 |
|
10% discount for BIS |
3.4(Disconnection from the mains supply) |
- |
1000 |
|
10% discount for BIS |
7.1(General) |
- |
500 |
|
10% discount for BIS |
1.5(Components) |
- |
5000 |
|
10% discount for BIS |
1.5(Components) |
- |
5000 |
|
10% discount for BIS |
2.8.2/2.8.5(Interlock switches) |
- |
1000 |
|
10% discount for BIS |
2.8.7(Switches and Relay) |
- |
1000 |
|
10% discount for BIS |
2.10.4.2(Material Group and Comparative Tracking Index) |
- |
3000 |
|
10% discount for BIS |
2.10.5.3(Insulating Compound as Solid Insulation) |
- |
500 |
|
10% discount for BIS |
2.10.5.4(Opto-coupler) |
- |
500 |
|
10% discount for BIS |
2.10.5.6(Thin sheet materials) |
- |
500 |
|
10% discount for BIS |
2.10.5.11(SMPS Transformer and Inductor) |
- |
500 |
|
10% discount for BIS |
2.10.5.12(Wires in wound components) |
- |
500 |
|
10% discount for BIS |
2.10.5.13(Winding wire) |
- |
500 |
|
10% discount for BIS |
2.10.5.14(Additional insulation in wound components) |
- |
500 |
|
10% discount for BIS |
2.10.6(PCB material) |
- |
500 |
|
10% discount for BIS |
2.10.8.2(Thermal conditioning (thermal ageing)) |
- |
500 |
|
10% discount for BIS |
2.10.8.4(Abrasion resistance test) |
- |
500 |
|
10% discount for BIS |
2.10.9(Thermal Cycling) |
- |
1000 |
|
10% discount for BIS |
2.10.10(Test for Pollution Degree 1 environment and for insulating compound) |
- |
500 |
|
10% discount for BIS |
2.10.11(Tests for semiconductor devices and for cemented joints) |
- |
500 |
|
10% discount for BIS |
2.10.12(Enclosed and sealed parts) |
- |
500 |
|
10% discount for BIS |
3.1.4(Internal wire) |
- |
500 |
|
10% discount for BIS |
3.2.4(Appliance inlet /connector) |
- |
500 |
|
10% discount for BIS |
3.2.5(Non re-wirable plug with PVC sheathed cable) |
- |
500 |
|
10% discount for BIS |
4.3.8(Batteries) |
- |
2500 |
|
10% discount for BIS |
4.3.10(Dust, powders, liquids and gases) |
- |
500 |
|
10% discount for BIS |
4.3.11(Containers for liquids or gases) |
- |
500 |
|
10% discount for BIS |
4.3.12(Flammable liquids) |
- |
500 |
|
10% discount for BIS |
Annex A3(Hot flaming oil test) |
- |
1000 |
|
10% discount for BIS |
Annex U(Insulating winding wires for use without interleaved insulation) |
- |
500 |
|
10% discount for BIS |
Annex CC(Evaluation of integrated circuit (IC) current limiters) |
- |
500 |
|
10% discount for BIS |
Annex K(Thermal Control) |
- |
500 |
|
10% discount for BIS |
Annex Q(Voltage Dependent Resistors) |
- |
500 |
|
10% discount for BIS |
|
Complete
|
|
24 May, 2025 |
- EXCLUSIONS: Visual Display unit, video monitors of screen size restricted up to 60" EXCLUSIONS:
Cl no.: 1.5 Components (Approved component used, verified based on certificates)
Cl no. :2.8.5 Moving parts Cl no.: 2.8.7 Switches and relay Cl no.: 2.10.5.4 Semiconductor devices Cl no.:4.2.9 High Pressure Lamps (Compliance will be checked with approved test report) Cl no.: 4.3.13 Radiation Annex A. 3: Hot flaming oil test
Annex H: lonizing radiation Annex K. Thermal Controls Annex Q: Voltage dependent
Resistors (VDRs) Annex R. Examples of requirements for quality control Programmes Annex U: Insulated winding wires for use without interleaved Insulation Annex Y: Ultraviolet Light conditioning test Annex CC: Evaluation of Integrated circuits current limiters. |
8771 |
BLUESKY LAB LLP
| IS 302 : Part 2 : Sec 6 (2009) |
Safety of household and similar electrical appliances: Part 2 particular requirements: Sec 6 cooking ranges, hobs, ovens and similar appliances (First Revision) |
- |
-
|
23000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
6.0(Classification) |
- |
500 |
|
10% discount offered to BIS |
7.0(Marking and instructions) |
- |
1000 |
|
10% discount offered to BIS |
8.0(Protection against access to live part test) |
- |
1000 |
|
10% discount offered to BIS |
10.0(Power Input and current test) |
- |
1500 |
|
10% discount offered to BIS |
11.0(Heating test) |
- |
2800 |
|
10% discount offered to BIS |
13.0(Leakage current and electric strength test) |
- |
2500 |
|
10% discount offered to BIS |
14.0(Transient voltages) |
- |
1400 |
|
10% discount offered to BIS |
15.0(Moisture Resistance) |
- |
4200 |
|
10% discount offered to BIS |
16.0(Leakage current and electric strength test) |
- |
2100 |
|
10% discount offered to BIS |
17.0(Overload protection of transformers test) |
- |
1300 |
|
10% discount offered to BIS |
19.0(Abnormal Operations) |
- |
2000 |
|
10% discount offered to BIS |
20.0(Stability and Mechanical Hazards) |
- |
1500 |
|
10% discount offered to BIS |
21.0(Mechanical Strength) |
- |
1800 |
|
10% discount offered to BIS |
22.0(Construction verification related tests) |
- |
5500 |
|
10% discount offered to BIS |
23.0(Internal wiring) |
- |
800 |
|
10% discount offered to BIS |
24.0(Components) |
- |
1300 |
|
10% discount offered to BIS |
25.0(Supply connections and External Flexible Cords) |
- |
1600 |
|
10% discount offered to BIS |
26.0(Terminal for External Conductors) |
- |
1000 |
|
10% discount offered to BIS |
27.0(Provision for Earthing) |
- |
2100 |
|
10% discount offered to BIS |
28.0(Screws and connections) |
- |
800 |
|
10% discount offered to BIS |
29.0(Clearances and Creepage distances and solid insulation) |
- |
2550 |
|
10% discount offered to BIS |
30.0(Resistance to heat and fire) |
- |
6000 |
|
10% discount offered to BIS |
31.0(Resistance to rusting) |
- |
2100 |
|
10% discount offered to BIS |
19.11.4.4(Surge immunity test) |
- |
2000 |
|
10% discount offered to BIS |
|
Complete
|
|
22 May, 2028 |
- [0:26 pm, 24/05/2022] Aslam office: EMI/EMC tests (electrostatic Discharges,
Radiant Fields, Fast Transient burst, [0:26 pm, 24/05/2022] Aslam office: Voltage surges, Injected current, voltage dips & Interruptions, Mains signals) [cl.19.11.4.1 to Cl.19.11.4.7], Radiation,
Toxicity & Similar Hazards (cl.32), Components (Cl.24), endurance of switches (Cl.24.1.3),
endurance of automatic controls (Cl.24.1.4) |
8772 |
BLUESKY LAB LLP
| IS 4250 (1980) |
Specification for domestic electric food - Mixers (Liquidizers And Grinders) (First Revision) |
- |
-
|
20000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
6(Classification- IS 302-1 ) |
- |
300 |
|
10% discount offered to BIS |
7.1(Marking- IS 302-1) |
- |
0.00 |
|
- |
7.2(Marking) |
- |
0 |
|
- |
7.4(Marking) |
- |
0 |
|
- |
7.5(Marking) |
- |
0 |
|
- |
7.6(Marking) |
- |
0 |
|
- |
7.1(Marking- IS 302-1) |
- |
500 |
|
10% discount offered to BIS |
8( Protection Against Electric Shock, IS 302-1) |
- |
500 |
|
10% discount offered to BIS |
9(Starting, IS 302-1) |
- |
500 |
|
10% discount offered to BIS |
10(Power Input and Current, IS 302-1) |
- |
700 |
|
10% discount offered to BIS |
11(Heating, IS 302-1) |
- |
1000 |
|
10% discount offered to BIS |
13(Electrical Insulation and Leakage Current at Operating Temperature: Leakage current, IS 302-1) |
- |
500 |
|
10% discount offered to BIS |
14(Transient Over Voltages, IS 302-1) |
- |
500 |
|
10% discount offered to BIS |
15.1(Moisture Resistance, IS 302-1) |
- |
800 |
|
10% discount offered to BIS |
13(Electrical Insulation and Leakage Current at Operating Temperature: High Voltage, IS 302-1) |
- |
500 |
|
10% discount offered to BIS |
16(Electrical Insulation and Leakage Current at Operating Temperature: Leakage current, IS 302-1) |
- |
500 |
|
10% discount offered to BIS |
16(Electrical Insulation and Leakage Current at Operating Temperature: High Voltage, IS 302-1) |
- |
500 |
|
10% discount offered to BIS |
19(Abnormal Operation, IS 302-1) |
- |
700 |
|
10% discount offered to BIS |
20(Stability & Mechanical Hazards, IS 302-1) |
- |
500 |
|
10% discount offered to BIS |
21(Mechanical Strength, IS 302-1) |
- |
500 |
|
10% discount offered to BIS |
22.1(Construction, IS 302-1) |
- |
100 |
|
10% discount offered to BIS |
22.2(Construction) |
- |
100 |
|
10% discount offered to BIS |
22.3(Construction) |
- |
100 |
|
10% discount offered to BIS |
22.4(Construction) |
- |
100 |
|
10% discount offered to BIS |
22.5(Construction) |
- |
100 |
|
10% discount offered to BIS |
22.6(Construction) |
- |
100 |
|
10% discount offered to BIS |
22.8(Construction) |
- |
100 |
|
10% discount offered to BIS |
22.9(Construction) |
- |
100 |
|
10% discount offered to BIS |
22.1(Construction) |
- |
100 |
|
10% discount offered to BIS |
23(Internal Wiring, IS 302-1) |
- |
500 |
|
10% discount offered to BIS |
24.1(Components, IS 302-1) |
- |
500 |
|
10% discount offered to BIS |
25(Supply Connection and External Flexible Cords, IS 302-1) |
- |
700 |
|
10% discount offered to BIS |
26(Terminals for External Conductors, IS 302-1) |
- |
500 |
|
10% discount offered to BIS |
27(Provision for Earthing, IS 302-1) |
- |
700 |
|
10% discount offered to BIS |
28(Screws & Connections, IS 302-1) |
- |
400 |
|
10% discount offered to BIS |
29(Clearances and Distances through Insulation, IS 302-1) |
- |
700 |
|
10% discount offered to BIS |
30(Resistance to Heat, Fire, Tracking, IS 302-1) |
- |
1000 |
|
10% discount offered to BIS |
31(Resistance of Rusting, IS 302-1) |
- |
1000 |
|
10% discount offered to BIS |
34.2(Operational tests- Grinding coffee (for machines which have a dry grinding arrangement)) |
- |
1000 |
|
10% discount offered to BIS |
34.3(Whisking egg whites ) |
- |
1000 |
|
10% discount offered to BIS |
34.4(IDLI batter-Grinding of black gram) |
- |
1000 |
|
10% discount offered to BIS |
34.5.1 (a)(Operational test for juicers ) |
- |
500 |
|
10% discount offered to BIS |
34.5.1 (b)(Operational test for juicers ) |
- |
500 |
|
10% discount offered to BIS |
34.5.2(Operational test for juicers ) |
- |
300 |
|
10% discount offered to BIS |
35(Temperature withstand test for bowl) |
- |
500 |
|
10% discount offered to BIS |
36(Test for controls ) |
- |
1000 |
|
10% discount offered to BIS |
37(Strength of Assembly ) |
- |
1000 |
|
10% discount offered to BIS |
|
Complete
|
|
22 May, 2028 |
- EMI/EMC tests (Electrostatic discharges, radiant fields, fast transient bursts, voltage Surges, injected current, voltage dip and interruption, mains signals) (Cl.19.11.4.1 to
19.11.4.7), Radio Intreference Suppression test(Cl.14)' |
8773 |
BLUESKY LAB LLP
| IS 8978 (1992) |
Specification for electric instantaneous water heaters (Second Revision) |
- |
-
|
19000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
Cl.10 of IS 8978 : 1992(Finish) |
- |
300 |
|
10% discount for BIS |
Cl.11 of IS 8978 : 1992(Operation of flow switch) |
- |
1700 |
|
10% discount for BIS |
Cl.12 of IS 8978 : 1992(Endurance) |
- |
1700 |
|
10% discount for BIS |
Cl.6 of IS 302-2-35:2017(Classification) |
- |
600 |
|
10% discount for BIS |
Cl.7 of IS 302-2-35:2017(Marking) |
- |
600 |
|
10% discount for BIS |
Cl.8 of IS 302-2-35:2017(Protection Against Access To Live Parts) |
- |
800 |
|
10% discount for BIS |
Cl.10 of IS 302-2- 35:2011(Power Input & Current ) |
- |
900 |
|
10% discount for BIS |
Cl.11 of 302-2-35:2017(Heating) |
- |
800 |
|
10% discount for BIS |
Cl.13 of IS 302-2-35:2017(Leakage Current & Electrical Strength at Operating Temperature ) |
- |
400 |
|
10% discount for BIS |
Cl.14 of IS 302-2-35:2017(Transient Over Voltages ) |
- |
1100 |
|
10% discount for BIS |
Cl.15 of IS 302-2-35-2011(Moisture Resistance ) |
- |
1500 |
|
10% discount for BIS |
Cl.16 of IS 302-2-35:2011(Leakage Current and Electric Strength) |
- |
1200 |
|
10% discount for BIS |
Cl.17 IS 302-2-35:2017(Overload Protection of Transformers & Associated circuits ) |
- |
700 |
|
10% discount for BIS |
Cl.19 of IS 302-2-35:2017(Abnormal Operation) |
- |
1200 |
|
10% discount for BIS |
Cl.20 of IS 302-2-35-2011(Stability & Mechanical Hazards
) |
- |
600 |
|
10% discount for BIS |
Cl.21.1 of IS 302-2-35-2011(Mechanical strength) |
- |
400 |
|
10% discount for BIS |
Cl. 21.2 of IS 302-1:2008(Mechanical strength) |
- |
400 |
|
10% discount for BIS |
Cl.22 of IS 302-2-35-2011(Construction
) |
- |
400 |
|
10% discount for BIS |
Cl.23 of IS 302-2-35-2011(Internal Wiring) |
- |
500 |
|
10% discount for BIS |
Cl.24 of IS 302-2-35:2017(Component
) |
- |
600 |
|
10% discount for BIS |
Cl.25 of IS 302-2-35:2017(Supply Connection & External Flexible Cords) |
- |
600 |
|
10% discount for BIS |
Cl.26 of IS 302-2-35:2017(Terminals for External Conductors) |
- |
400 |
|
10% discount for BIS |
Cl.27 of IS 302-2-35:2017(Provision for Earthing) |
- |
600 |
|
10% discount for BIS |
Cl.28 of IS 302-2-35:2017(Screws and Connections
) |
- |
600 |
|
10% discount for BIS |
Cl.29 of IS 302-2-35:2017(Clearances, Creepage Distances and Solid Insulation) |
- |
500 |
|
10% discount for BIS |
Cl.30 of IS 302-2-35: 2011(Resistance to Heat and Fire) |
- |
1100 |
|
10% discount for BIS |
Cl.31 of IS 302-2-35: 2011(Resistance to Rusting
) |
- |
700 |
|
10% discount for BIS |
|
Complete
|
|
22 May, 2028 |
- Restricted to steel tanks only and with rated pressure upto 1.2MPA EMI/EMC tests (Electrostatic discharges, radiant fields, fast transient bursts, voltage surges, injected current, voltage dip and
interruption, mains signals) (Cl.19.11.4.1 to 19.11.4.7) |
8774 |
BLUESKY LAB LLP
| IS 2082 (2018) |
Stationary storage type electric water heaters - Specification (Fifth Revision) |
- |
-
|
20000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
Cl.15 of IS 2082:2018(Verification of the Rated Capacity) |
- |
900 |
|
10% discount offered to BIS |
Cl.16 of IS 2082:2018(Standing Loss per 24 Hours) |
- |
4000 |
|
10% discount offered to BIS |
Cl.17 of IS 2082:2018(Hot Water Output) |
- |
1000 |
|
10% discount offered to BIS |
Cl.18 of IS 2082:2018( Reheating Time) |
- |
1200 |
|
10% discount offered to BIS |
Cl.19 of IS 2082:2018(Mixing Factor) |
- |
800 |
|
10% discount offered to BIS |
Cl.20 of IS 2082:2018(Deviation of Dial Calibration) |
- |
900 |
|
10% discount offered to BIS |
Cl.21 of IS 2082:2018(Cyclic Temperature Variation) |
- |
1000 |
|
10% discount offered to BIS |
Cl.22 of IS 2082:2018(Finish) |
- |
500 |
|
10% discount offered to BIS |
6(Classification ) |
- |
600 |
|
10% discount offered to BIS |
7(Marking) |
- |
600 |
|
10% discount offered to BIS |
(Cl.8 of IS 302-2-21:2011)(Protection Against Access to Live Parts) |
- |
800 |
|
10% discount offered to BIS |
(Cl.10 of IS 302-2-21: 2011)(Power Input & Current) |
- |
1200 |
|
10% discount offered to BIS |
(Cl.11 of 302-2-21:2011)(Heating) |
- |
800 |
|
10% discount offered to BIS |
(Cl.13 of IS 302-2-21:2011)(Leakage Current ) |
- |
400 |
|
10% discount offered to BIS |
(Cl.13 of IS 302-2-21:2011)(Electrical Strength at Operating Temperature) |
- |
400 |
|
10% discount offered to BIS |
(Cl.14ofIS302-2-21:2011)(Transient Over Voltages) |
- |
1100 |
|
10% discount offered to BIS |
(Cl.15 of IS 302-2-21-2011)(Moisture Resistance) |
- |
1400 |
|
10% discount offered to BIS |
(Cl.17 of IS 302-2-21:2011)(Overload protection of transformers & associated circuits) |
- |
900 |
|
10% discount offered to BIS |
(Cl.19 of IS 302-2-21:2011)(Abnormal Operation) |
- |
1500 |
|
10% discount offered to BIS |
(Cl.20 of IS 302-2-21:2011)(Stability & Mechanical Hazards) |
- |
600 |
|
10% discount offered to BIS |
(Cl.21ofIS302-2-21:2011)(Mechanical strength) |
- |
400 |
|
10% discount offered to BIS |
(Cl.22 Of
IS 302-2-21:2011)(Construction) |
- |
400 |
|
10% discount offered to BIS |
(Cl. 23 of IS 302-2-21: 2011)(Internal Wiring
) |
- |
700 |
|
10% discount offered to BIS |
(Cl.24ofIS302-221:2011)(Component) |
- |
500 |
|
10% discount offered to BIS |
(Cl.25 of IS 302-2-21:2011)(Supply Connection & External Flexible Cords) |
- |
600 |
|
10% discount offered to BIS |
(Cl.26 of IS 302-2-21: 2011)(Terminals for External Conductors) |
- |
400 |
|
10% discount offered to BIS |
(Cl.27 of IS 302-2-21:2011)(Provision for Earthing) |
- |
600 |
|
10% discount offered to BIS |
(Cl.28 of IS 302-2-21:2011)(Screws & Connections) |
- |
600 |
|
10% discount offered to BIS |
(Cl.29ofIS302-2-21:2011)(Clearances, Creepage Distances and Solid Insulation) |
- |
500 |
|
10% discount offered to BIS |
(Cl.30 of IS 302-2-21:2011)(Resistance to Heat & Fire) |
- |
1200 |
|
10% discount offered to BIS |
(Cl.31 of IS 302-2-21:2011)(Resistance to Rusting) |
- |
800 |
|
10% discount offered to BIS |
Cl.16 of IS 302-2-21-2018(Leakage current and Electric strength (After humidity): Leakage current ) |
- |
600 |
|
10% discount offered to BIS |
Cl.16 of IS 302-2-21-2018(Leakage current and Electric strength (After humidity): Electric Strentgh ) |
- |
600 |
|
10% discount offered to BIS |
|
Complete
|
|
22 May, 2028 |
- - |
8775 |
BLUESKY LAB LLP
| IS 302 : Part 2 : Sec 35 (2017) |
Safety of household and similar electrical appliances: Part 2 particular requirements: Sec 35 electric instantaneous water heaters (Second Revision) |
- |
-
|
16613 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
Cl. 6
IS 302-2-35(Classification) |
- |
600 |
|
10% discount offered to BIS |
Cl. 7
IS 302-2-35(Marking and Instruction) |
- |
600 |
|
10% discount offered to BIS |
Cl. 8
IS 302-2-35(Protection against access to live parts) |
- |
800 |
|
10% discount offered to BIS |
Cl. 10
IS 302-2-35(Power Input and Current ) |
- |
900 |
|
10% discount offered to BIS |
Cl. 11
IS 302-2-35(Heating) |
- |
800 |
|
10% discount offered to BIS |
Cl. 13
IS 302-2-35(Leakage Current & Electric Strength at Operating Temperature) |
- |
400 |
|
10% discount offered to BIS |
Cl. 14
IS 302-2-35(Radio and television interference suppression / Transient over voltages) |
- |
1100 |
|
10% discount offered to BIS |
Cl. 15
IS 302-2-35(Moisture Resistance Test ) |
- |
1400 |
|
10% discount offered to BIS |
Cl. 16
IS 302-2-35(Leakage Current & Electric Strength at Operating Temperature (After Humidity Treatment)) |
- |
1200 |
|
10% discount offered to BIS |
Cl. 17
IS 302-2-35(Overload Protection of Transformers and Associated Circuit) |
- |
700 |
|
10% discount offered to BIS |
Cl. 19
IS 302-2-35(Abnormal Operation ) |
- |
1200 |
|
10% discount offered to BIS |
Cl. 20
IS 302-2-35(Stability & Mechanical Hazards) |
- |
600 |
|
10% discount offered to BIS |
Cl. 21
IS 302-2-35(Mechanical strength) |
- |
400 |
|
10% discount offered to BIS |
Cl. 22
IS 302-2-35(Construction ) |
- |
400 |
|
10% discount offered to BIS |
Cl. 23
IS 302-2-35(Internal Wiring) |
- |
500 |
|
10% discount offered to BIS |
Cl. 24
IS 302-2-35(Components) |
- |
600 |
|
10% discount offered to BIS |
Cl. 25
IS 302-2-35(Supply Connection & External Flexible Cords) |
- |
600 |
|
10% discount offered to BIS |
Cl. 26
IS 302-2-35(Terminals for External conductors ) |
- |
400 |
|
10% discount offered to BIS |
Cl. 27
IS 302-2-35(Provision for Earthing ) |
- |
600 |
|
10% discount offered to BIS |
Cl. 28
IS 302-2-35(Screws & Connections) |
- |
600 |
|
10% discount offered to BIS |
Cl. 29
IS 302-2-35(Clearances, Creepage Distances & Solid insulation ) |
- |
500 |
|
10% discount offered to BIS |
Cl. 30
IS 302-2-35(Resistance to Heat Fire & Tracking ) |
- |
1100 |
|
10% discount offered to BIS |
Cl.31(Verification) |
- |
700 |
|
10% discount offered to BIS |
Cl. 31
IS 302-2-35(Resistance to Rusting) |
- |
700 |
|
10% discount offered to BIS |
19.11.4.4(Surge immunity test) |
- |
2000 |
|
10% discount offered to BIS |
|
Complete
|
|
22 May, 2028 |
- Restricted to rated pressure upto 1.2MPA. EMI/EMC tests (electrostatic Discharges,
Radiant Fields, Fast Transient burst, Voltage surges, Injected current, voltage
dips & Interruptions, Mains signals) [cl.19.11.4.1 to Cl.19.11.4.7], Components
(Capacitors for radio interference suppression, isolating transformer,
coupler) (Cl.24.1.1, 24.1.2, 24.1) Note: Copper purity declared by manufacturer. |
8776 |
BLUESKY LAB LLP
| IS 302 : Part 2 : Sec 26 (2014) |
Safety of household and similar electrical appliances: Part 2 particular requirements: Sec 26 clocks (First Revision) |
- |
-
|
25000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
6.0(Classification) |
- |
500 |
|
10% discount offered to BIS |
7(Marking and instructions) |
- |
600 |
|
10% discount offered to BIS |
8(Protection against live parts) |
- |
1000 |
|
10% discount offered to BIS |
10(POWER INPUT AND CURRENT) |
- |
1800 |
|
10% discount offered to BIS |
11(HEATING) |
- |
2000 |
|
10% discount offered to BIS |
13(LEAKAGE CURRENT AND ELECTRIC STRENGTH AT OPERATING TEMPERATURE) |
- |
1100 |
|
10% discount offered to BIS |
14(TRANSIENT OVERVOLTAGES) |
- |
1500 |
|
10% discount offered to BIS |
15(MOISTURE RESISTANCE) |
- |
2000 |
|
10% discount offered to BIS |
16(LEAKAGE CURRENT AND ELECTRIC STRENGTH) |
- |
1500 |
|
10% discount offered to BIS |
17(OVERLOAD PROTECTION OF TRANSFORMERS AND ASSOCIATED CIRCUITS) |
- |
1100 |
|
10% discount offered to BIS |
19(ABNORMAL OPERATION) |
- |
1500 |
|
10% discount offered to BIS |
20(STABILITY AND MECHANICAL HAZARDS) |
- |
500 |
|
10% discount offered to BIS |
21(MECHANICAL STRENGTH) |
- |
1500 |
|
10% discount offered to BIS |
22(CONSTRUCTION) |
- |
2000 |
|
10% discount offered to BIS |
23(INTERNAL WIRING) |
- |
1100 |
|
10% discount offered to BIS |
24(COMPONENTS) |
- |
800 |
|
10% discount offered to BIS |
25(SUPPLY CONNECTION AND EXTERNAL FLEXIBLE CORDS) |
- |
1500 |
|
10% discount offered to BIS |
26(TERMINALS FOR EXTERNAL CONDUCTORS) |
- |
500 |
|
10% discount offered to BIS |
27(PROVISION FOR EARTHING) |
- |
1000 |
|
10% discount offered to BIS |
28(SCREWS AND CONNECTIONS) |
- |
900 |
|
10% discount offered to BIS |
29(CLEARANCES, CREEPAGE DISTANCES AND SOLID INSULATION) |
- |
1400 |
|
10% discount offered to BIS |
30(RESISTANCE TO HEAT AND FIRE) |
- |
1800 |
|
10% discount offered to BIS |
31(RESISTANCE TO RUSTING) |
- |
1800 |
|
10% discount offered to BIS |
|
Complete
|
|
22 May, 2028 |
- Cl. 19.11.4.1 to 19.11.4.4 EMI/EMC, Cl. 24 Components, Radiation, Toxicity & Similar
Hazards (cl.32) |
8777 |
BLUESKY LAB LLP
| IS 302 : Part 2 : Sec 25 (2014) |
Safety of household and similar electrical appliances: Part 2 Particular requirements: Section 25 Microwave ovens |
- |
-
|
40000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
6.0(Classification) |
- |
500 |
|
10% discount offered to BIS |
7(Marking and instructions) |
- |
1000 |
|
10% discount offered to BIS |
8(Protection against live parts) |
- |
900 |
|
10% discount offered to BIS |
10(POWER INPUT AND CURRENT) |
- |
1500 |
|
10% discount offered to BIS |
11(HEATING) |
- |
2500 |
|
10% discount offered to BIS |
13(LEAKAGE CURRENT AND ELECTRIC STRENGTH AT OPERATING TEMPERATURE) |
- |
1500 |
|
10% discount offered to BIS |
14(IMPULSE VOLTAGE TEST) |
- |
1800 |
|
10% discount offered to BIS |
15(HUMIDITY TREATMENT TEST) |
- |
3500 |
|
10% discount offered to BIS |
16(LEAKAGE CURRENT AND ELECTRIC STRENGTH) |
- |
2200 |
|
10% discount offered to BIS |
17(OVERLOAD PROTECTION OF TRANSFORMERS AND ASSOCIATED CIRCUITS) |
- |
1600 |
|
10% discount offered to BIS |
18(ENDURANCE) |
- |
1800 |
|
10% discount offered to BIS |
19(ABNORMAL OPERATION) |
- |
2400 |
|
10% discount offered to BIS |
20(STABILITY AND MECHANICAL HAZARDS) |
- |
1200 |
|
10% discount offered to BIS |
21(MECHANICAL STRENGTH) |
- |
1500 |
|
10% discount offered to BIS |
22(CONSTRUCTION) |
- |
4000 |
|
10% discount offered to BIS |
23(INTERNAL WIRING) |
- |
1000 |
|
10% discount offered to BIS |
24(COMPONENTS) |
- |
800 |
|
10% discount offered to BIS |
25(SUPPLY CONNECTION AND EXTERNAL FLEXIBLE CORDS) |
- |
1100 |
|
10% discount offered to BIS |
26(TERMINALS FOR EXTERNAL CONDUCTORS) |
- |
1100 |
|
10% discount offered to BIS |
27(PROVISION FOR EARTHING) |
- |
1800 |
|
10% discount offered to BIS |
28(SCREWS AND CONNECTIONS) |
- |
1100 |
|
10% discount offered to BIS |
29(CLEARANCES, CREEPAGE DISTANCES AND SOLID INSULATION) |
- |
1200 |
|
10% discount offered to BIS |
30(RESISTANCE TO HEAT AND FIRE) |
- |
4500 |
|
10% discount offered to BIS |
31(RESISTANCE TO RUSTING) |
- |
1800 |
|
10% discount offered to BIS |
32(RADIATION, TOXICITY AND SIMILAR HAZARDS) |
- |
2500 |
|
10% discount offered to BIS |
|
Complete
|
|
22 May, 2028 |
- Cl.19.11.4 EMI/EMC -- Cl.24 Components ( Magnetron, HV
transformer capacitor diode, Capacitor and RC units RF Suppression X-Y capacitor, PCB
Material, Inductor SMPS Transformer, MOV/VDR, Relays, Power cord, Thermal
Cut-out / Thermostat Appliance connector Inlet Door Interlock Switches, IP category,
Enclosure insulation material, Bridging resistor)Cyclic(Sodium Chloride solution) |
8778 |
BLUESKY LAB LLP
| IS 302 : Part 2 : Sec 21 (2018) |
Safety of household and similar electrical appliances: Part 2 particular requirements: Sec 21 stationary storage type electric water heaters (Second Revision) |
- |
-
|
16500 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
6.0(Classification) |
- |
600 |
|
10% discount offered to BIS |
7.0(Marking and Instructions) |
- |
600 |
|
10% discount offered to BIS |
8.0(Protection against access to live parts) |
- |
800 |
|
10% discount offered to BIS |
10.0(Input and Current) |
- |
1200 |
|
10% discount offered to BIS |
11.0(Heating) |
- |
800 |
|
10% discount offered to BIS |
13.0(Leakage Current and electric strength at operating temperature) |
- |
400 |
|
10% discount offered to BIS |
14.0(Transient Overvoltage) |
- |
1100 |
|
10% discount offered to BIS |
15.0(Moisture resistance) |
- |
1400 |
|
10% discount offered to BIS |
16.0(Leakage current and Electric strength (After Humidity (Environmental) Treatment)) |
- |
1200 |
|
10% discount offered to BIS |
17.0(Overload Protection of transformer and associated circuit) |
- |
900 |
|
10% discount offered to BIS |
19.0(Abnormal Operation) |
- |
1500 |
|
10% discount offered to BIS |
20.0(Stability and mechanical hazards) |
- |
600 |
|
10% discount offered to BIS |
21.0(Mechanical Strength) |
- |
400 |
|
10% discount offered to BIS |
22.0(Construction) |
- |
400 |
|
10% discount offered to BIS |
23.0(Internal Wiring) |
- |
700 |
|
10% discount offered to BIS |
25.0(Supply Connection and External Flexible Cords) |
- |
600 |
|
10% discount offered to BIS |
26.0(Terminals for external conductors) |
- |
400 |
|
10% discount offered to BIS |
27.0(Provision For Earthing) |
- |
600 |
|
10% discount offered to BIS |
28.0(Screws and Connections) |
- |
600 |
|
10% discount offered to BIS |
29.0(Creepage Distances and Clearances) |
- |
500 |
|
10% discount offered to BIS |
30.0(Resistance To Heat and Fire) |
- |
1200 |
|
10% discount offered to BIS |
31.0(Resistance To Rusting) |
- |
800 |
|
10% discount offered to BIS |
24(Components) |
- |
500 |
|
10% discount offered to BIS |
19.11.4.4(Surge immunity test) |
- |
2000 |
|
10% discount offered to BIS |
|
Complete
|
|
22 May, 2028 |
- Restricted to rated pressure upto 1.2MPA. EMI/EMC tests (electrostatic Discharges,
Radiant Fields, Fast Transient burst, Voltage surges, Injected current, voltage
dips & Interruptions, Mains signals) [cl.19.11.4.1 to Cl.19.11.4.7], Radiation, Toxicity & Similar Hazards (cl.32), Components (C1.24) Note: Copper purity declared by manufacturer. |
8779 |
Bharat Test House Pvt Ltd 1474 Haryana
| IS/IEC 61730 : PART 1 (2004) |
Photovoltaic (PV) Module Safety Qualification Part 1 Requirements for Construction |
- |
-
|
468500 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
3(Application classes) |
- |
0 |
|
- |
4(Construction requirements) |
- |
0 |
|
- |
5(Polymeric materials) |
- |
250000 |
|
- |
6(Internal wiring and current-carrying parts) |
- |
7500 |
|
- |
7(Connections) |
- |
75000 |
|
- |
8(Bonding and grounding) |
- |
7500 |
|
- |
9(Creepage and clearance distances) |
- |
17500 |
|
- |
10(Field wiring compartments with covers) |
- |
110000 |
|
- |
11(Marking) |
- |
1000 |
|
- |
12() |
- |
0 |
|
- |
3(Application classes) |
- |
0 |
|
5% discount for BIS |
4(Construction requirements) |
- |
0 |
|
5% discount for BIS |
5(Polymeric materials) |
- |
250000 |
|
5% discount for BIS |
6(Internal wiring and current-carrying parts) |
- |
7500 |
|
5% discount for BIS |
7(Connections) |
- |
75000 |
|
5% discount for BIS |
8(Bonding and grounding) |
- |
7500 |
|
5% discount for BIS |
9(Creepage and clearance distances) |
- |
17500 |
|
5% discount for BIS |
10(Field wiring compartments with covers) |
- |
110000 |
|
5% discount for BIS |
11(Marking) |
- |
1000 |
|
5% discount for BIS |
12() |
- |
0 |
|
5% discount for BIS |
|
Complete
|
|
19 Mar, 2026 |
- - |
8780 |
BLUESKY LAB LLP
| IS 368 (2014) |
Electric immersion water heaters - Specification (Fifth Revision) |
- |
-
|
19000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
Cl.6 of IS 302-‐2-‐201:2008(Classification) |
- |
500 |
|
10% discount offered to BIS |
Cl.7 of IS 302-2-201:2008(Marking and Instruction ) |
- |
600 |
|
10% discount offered to BIS |
Cl.8 of IS 302‐2-201: 2008(Protection Against Access to Live Parts) |
- |
1000 |
|
10% discount offered to BIS |
Cl.10 of IS 302‐2‐201:2008(Power Input and Current ) |
- |
1200 |
|
10% discount offered to BIS |
Cl.11 of IS 302-2201: 2008(Heating) |
- |
1100 |
|
10% discount offered to BIS |
Cl. 12 of IS 368:2014(Operation under overload conditions of appliances with heating elements) |
- |
1000 |
|
10% discount offered to BIS |
Cl.13 of IS 302-2-201: 2008(Leakage Current & Electric Strength at Operating Temperature) |
- |
600 |
|
10% discount offered to BIS |
Cl.14 of IS 302‐2-201:2008(Transient Over Voltages ) |
- |
900 |
|
10% discount offered to BIS |
Cl.15 of IS 302-2-201:2008(Moisture Resistance ) |
- |
1200 |
|
10% discount offered to BIS |
Cl.16 of IS 302-2-201:2008(Leakage Current & Electric Strength) |
- |
1100 |
|
10% discount offered to BIS |
Cl.17 of IS 302‐2-201: 2008(Overload Protection of Transformers & Associated Circuits) |
- |
900 |
|
10% discount offered to BIS |
Cl.18 of IS 368:2014(Endurance) |
- |
1100 |
|
10% discount offered to BIS |
Cl.19 of IS 302‐2-201: 2008(Abnormal Operation ) |
- |
1500 |
|
10% discount offered to BIS |
Cl.20 of IS 302-2-201: 2008(Stability & Mechanical Hazards) |
- |
500 |
|
10% discount offered to BIS |
Cl.21 of IS 302-2-201: 2008(Mechanical Strength ) |
- |
600 |
|
10% discount offered to BIS |
Cl.22 of IS 302-2-201: 2008(Construction) |
- |
400 |
|
10% discount offered to BIS |
Cl.23 of 302-2-201:2008(Internal Wiring ) |
- |
500 |
|
10% discount offered to BIS |
Cl.24 of IS 302-2-201: 2008(Component) |
- |
500 |
|
10% discount offered to BIS |
Cl.25 of IS 302-2-201: 2008(Supply Connection and External Flexible Cords) |
- |
600 |
|
10% discount offered to BIS |
Cl.26 of IS 302-2-201: 2008(Terminals for External Conductors) |
- |
400 |
|
10% discount offered to BIS |
Cl.27 of IS 302-2-201: 2008(Provision for Earthing ) |
- |
700 |
|
10% discount offered to BIS |
Cl.28 of IS 302-2-201: 2008(Screws & Connections ) |
- |
400 |
|
10% discount offered to BIS |
Cl.29 of IS 302-2‐201:2008(Clearances, Creepage Distances and Solid Insulation ) |
- |
600 |
|
10% discount offered to BIS |
Cl.30 of IS 302-2‐201:2008(Resistance to Heat and Fire ) |
- |
1200 |
|
10% discount offered to BIS |
Cl.31 of IS 302-2-201:2008(Resistance of Rusting ) |
- |
700 |
|
10% discount offered to BIS |
19.11.4.4(Surge immunity test) |
- |
2000 |
|
10% discount offered to BIS |
|
Complete
|
|
22 May, 2028 |
- Restricted Upto 5KW EMI/EMC tests (Electrostatic discharges, radiant fields, fast transient bursts, voltage
surges, injected current, voltage dip and interruption, mains signals) (Cl.19.11.4.1 to
19.11.4.7), Components (Capacitors for radio interference suppression, isolating transformer, coupler) (Cl.24.1.1, 24.1.2, 24.1.5) |
8781 |
BLUESKY LAB LLP
| IS 16333 : Part 3 (2017) |
Mobile phone handsets: Part 3 indian language support for mobile phone handsets - Specific requirements (First Revision) |
- |
-
|
15000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
5.1(Inputting of text) |
- |
7500 |
|
10% discount to BIS |
5.2(Message Readability) |
- |
7500 |
|
10% discount to BIS |
|
Complete
|
|
22 May, 2028 |
- - |
8782 |
BLUESKY LAB LLP
| IS 16103 : Part 1 (2012) |
Led modules for general lighting: Part 1 safety requirements |
- |
-
|
37500 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
7(Marking) |
- |
1500 |
|
10% discount offered to BIS |
8(Terminals) |
- |
2500 |
|
10% discount offered to BIS |
9(PROVISION FOR EARTHING) |
- |
2000 |
|
10% discount offered to BIS |
10(Protection against accidental contact with live parts) |
- |
2500 |
|
10% discount offered to BIS |
11(Mositure Resistance and Insulation) |
- |
8000 |
|
10% discount offered to BIS |
12(Electric Strength) |
- |
2000 |
|
10% discount offered to BIS |
13(Fault conditions) |
- |
5000 |
|
10% discount offered to BIS |
15(Construction) |
- |
5000 |
|
10% discount offered to BIS |
16(Creepage distance and clearances) |
- |
4000 |
|
10% discount offered to BIS |
17(Screws, current carrying parts and connections) |
- |
2500 |
|
10% discount offered to BIS |
18(Resistance to heat, fire and tracking) |
- |
4000 |
|
10% discount offered to BIS |
19(Resistance to corrosion) |
- |
2000 |
|
10% discount offered to BIS |
21(Heat management) |
- |
500 |
|
10% discount offered to BIS |
|
Complete
|
|
22 May, 2028 |
- Components (Cl.102) |
8783 |
BLUESKY LAB LLP
| IS 616 (2017) |
Audio, video and similar electronic apparatus - Safety requirements (Fifth Revision) |
- |
-
|
45000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
5(Marking and instructions) |
- |
1000.00 |
|
10% discount offered to BIS |
6(Hazardous radiations) |
- |
0.00 |
|
- |
7(Heating under normal operating conditions) |
- |
8000 |
|
10% discount offered to BIS |
8(Constructional requirements with regard to the protection against electric shock) |
- |
5000 |
|
10% discount offered to BIS |
9(Electric shock hazard under normal operating conditions) |
- |
7000 |
|
10% discount offered to BIS |
10(Insulation requirements) |
- |
5000 |
|
10% discount offered to BIS |
11(Fault conditions) |
- |
8000 |
|
10% discount offered to BIS |
12(Mechanical strength) |
- |
3000 |
|
10% discount offered to BIS |
13(CLEARANCES and CREEPAGE DISTANCES) |
- |
5000 |
|
10% discount offered to BIS |
15(TERMINALS) |
- |
2000 |
|
10% discount offered to BIS |
16(External flexible cords) |
- |
3000 |
|
10% discount offered to BIS |
17(Electrical connections and mechanical fixings) |
- |
2000 |
|
10% discount offered to BIS |
18(Mechanical strength of picture tubes and protection against the effects of implosion) |
- |
0.00 |
|
- |
19(Stability and mechanical hazards) |
- |
6000 |
|
10% discount offered to BIS |
20(Resistance to fire) |
- |
5000 |
|
10% discount offered to BIS |
14(Components) |
- |
1000 |
|
10% discount offered to BIS |
Annex-A(Additional requirements for apparatus with protection against splashing water) |
- |
1500 |
|
10% discount offered to BIS |
Annex-B(Apparatus to be connected to the TELECOMMUNICATION NETWORKS) |
- |
1200 |
|
10% discount offered to BIS |
|
Complete
|
|
22 May, 2028 |
- Ionizing radiation (Cl.6.1), Products other than with laser system class 1 (Cl. 6.2), Light a emitting (6.3), Endurance test for wound components with insulated winding wires without additional interleaved insulation (Cl.8.16), Endurance test for wound components with insulated winding wires without additional interleaved insulation (Cl.8.17), Printed boards (CL.13.5), Enclosed, enveloped or hermetically connected to the mains, clearness and creepage distanced (Cl. 13.7), Components (CL..14.0), 8 Plugs & sockets (Cl. 15.1), terminals for external flexible cords and for permanent connection to the mains supply (Cl 15.3), Mains cords sheathed type, complying with (Cl.16.1), Mechanical strength of Picture tubes & protection against the effect of implosion (Cl.18), Electrical component & mech. Parts (Cl.20.2),Resistors (Cl.14.2), Capacitors & RC units (Cl .14.3), Inductors & windings (Cl.14.4), High voltage components & assemblies (Cl.14.5), Protective devices (Cl.14.6), Thermal releases (14.6.2), Fuse & fuse holder (Cl.14.6.3), PTC thermistor (Cl.14.6.4), Switch (14.7), Batteries (Cl.14.11), Opto coupler (.14.12), Surge suppression varistors (14.13) |
8784 |
BLUESKY LAB LLP
| IS 10322 : Part 5 : Sec 9 (2017) |
Luminaires: Part 5 particular requirements: Sec 9 rope lights |
- |
-
|
55000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
21.4(General Test Requireements) |
- |
500 |
|
10% discount offered to BIS |
21.5(Classification of Luminaires') |
- |
500 |
|
10% discount offered to BIS |
21.6(Marking) |
- |
1500 |
|
10% discount offered to BIS |
21.7(Construction) |
- |
10000 |
|
10% discount offered to BIS |
21.8(Creepage Distance and Clearances) |
- |
3000 |
|
10% discount offered to BIS |
21.9(Provision for earthing) |
- |
2500 |
|
10% discount offered to BIS |
21.10(Terminals) |
- |
2500 |
|
10% discount offered to BIS |
21.11(External & Internal Wiring) |
- |
5000 |
|
10% discount offered to BIS |
21.12(Protection against electric shock) |
- |
2500 |
|
10% discount offered to BIS |
21.13(Endurance Tests and Thermal Tests) |
- |
10000 |
|
10% discount offered to BIS |
21.14(Resistance to Dust & Moisture) |
- |
7000 |
|
10% discount offered to BIS |
21.15(Insulation Resistance and Electric Strength) |
- |
3000 |
|
10% discount offered to BIS |
21.16(Resistance to Heat , fire and tracking) |
- |
5000 |
|
10% discount offered to BIS |
|
Complete
|
|
22 May, 2028 |
- Electrical endurance (CBC) (cl.20.7.4 & Cl.6.14.2 of Annex A), Bendings
(Nonrewireable connectors) (cl.20.7.4 & Cl.6.14.3 of Annex A), Control Unit
(Cl.20.7.8 & IEC 61347-2-11) IPX8 upto 1.3m |
8785 |
BLUESKY LAB LLP
| IS 10322 : Part 5 : Sec 7 (2017) |
Luminaires: Part 5 particular requirements: Sec 7 lighting chains (First Revision) |
- |
-
|
55000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
20.4(General Test Requireements) |
- |
500 |
|
10% discount offered to BIS |
20.5(Classification of Luminaires') |
- |
500 |
|
10% discount offered to BIS |
20.6(Marking) |
- |
1500 |
|
10% discount offered to BIS |
20.7(Construction) |
- |
10000 |
|
10% discount offered to BIS |
20.8(Creepage Distance and Clearances) |
- |
3000 |
|
10% discount offered to BIS |
20.9(Provision for earthing) |
- |
2500 |
|
10% discount offered to BIS |
20.10(Terminals) |
- |
2500 |
|
10% discount offered to BIS |
20.11(External & Internal Wiring) |
- |
5000 |
|
10% discount offered to BIS |
20.12(Protection against electric shock) |
- |
2500 |
|
10% discount offered to BIS |
20.13(Endurance Tests and Thermal Tests) |
- |
10000 |
|
10% discount offered to BIS |
20.14(Resistance to Dust & Moisture) |
- |
7000 |
|
10% discount offered to BIS |
20.15(Insulation Resistance and Electric Strength) |
- |
3000 |
|
10% discount offered to BIS |
20.16(Resistance to Heat , fire and tracking) |
- |
5000 |
|
10% discount offered to BIS |
|
Complete
|
|
22 May, 2028 |
- [0:22 pm, 24/05/2022] Aslam office: UV Radiations as per C. 4.24 & Annex P of
IS 10322 (Part 1):2014, Electrical endurance [0:23 pm, 24/05/2022] Aslam office: (CBC) (cl.20.7.4 & Cl.6.14.2 of Annex A), Bendings (Nonrewireable connectors) (cl.20.7.4 & Cl.6.14.3 of Annex A), Control
Unit (Cl.20.7.8 & IEC 61347-2-11) IPX8 upto 1.3m |
8786 |
BLUESKY LAB LLP
| IS 10322 : Part 5 : Sec 6 (2013) |
Luminaires: Part 5 particular requirements: Sec 6 handlamps |
- |
-
|
55000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
4(General Test Requireements) |
- |
500 |
|
10% discount offered to BIS |
5(Classification of Luminaires') |
- |
500 |
|
10% discount offered to BIS |
7.0(Construction) |
- |
10000 |
|
10% discount offered to BIS |
8.0(Creepage Distance and Clearances) |
- |
3000 |
|
10% discount offered to BIS |
9.0(Provision for earthing) |
- |
2500 |
|
10% discount offered to BIS |
10.0(Terminals) |
- |
2500 |
|
10% discount offered to BIS |
11.0(External & Internal Wiring) |
- |
5000 |
|
10% discount offered to BIS |
12.0(Protection against electric shock) |
- |
2500 |
|
10% discount offered to BIS |
13.0(Endurance Tests and Thermal Tests) |
- |
10000 |
|
10% discount offered to BIS |
14.0(Resistance to Dust & Moisture) |
- |
7000 |
|
10% discount offered to BIS |
15.0(Insulation Resistance and Electric Strength) |
- |
3000 |
|
10% discount offered to BIS |
16.0(Resistance to Heat , fire and tracking) |
- |
5000 |
|
10% discount offered to BIS |
6.0(Marking) |
- |
1500 |
|
10% discount offered to BIS |
|
Complete
|
|
22 May, 2028 |
- UV Radiation for Metal halide lamps (Cl.4.24, Annex-P) IPX8 upto 1.3m |
8787 |
BLUESKY LAB LLP
| IS 10322 : Part 5 : Sec 5 (2013) |
Luminaires: Part 5 particular requirements: Sec 5 floodlights (First Revision) |
- |
-
|
55000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
4(General Test Requireements) |
- |
500 |
|
10% discount offered to BIS |
5(Classification of Luminaires') |
- |
500 |
|
10% discount offered to BIS |
6.0(Marking) |
- |
1500 |
|
10% discount offered to BIS |
7.0(Construction) |
- |
8000 |
|
10% discount offered to BIS |
8.0(Creepage Distance and Clearances) |
- |
3000 |
|
10% discount offered to BIS |
9.0(Provision for earthing) |
- |
2500 |
|
10% discount offered to BIS |
10.0(Terminals) |
- |
2500 |
|
10% discount offered to BIS |
11.0(External & Internal Wiring) |
- |
5000 |
|
10% discount offered to BIS |
12.0(Protection against electric shock) |
- |
2500 |
|
10% discount offered to BIS |
13.0(Endurance Tests and Thermal Tests) |
- |
10000 |
|
10% discount offered to BIS |
14.0(Resistance to Dust & Moisture) |
- |
7000 |
|
10% discount offered to BIS |
15.0(Insulation Resistance and Electric Strength) |
- |
3000 |
|
10% discount offered to BIS |
16.0(Resistance to Heat , fire and tracking) |
- |
5000 |
|
10% discount offered to BIS |
17.0(Photometric Test) |
- |
25000 |
|
10% discount offered to BIS |
|
Complete
|
|
22 May, 2028 |
- Luminaries size restricted to 1000 mm for photometric test, UV Radiations as per C. 4
.24 & Annex P of IS 10322 (Part 1):2014, Short-circuit protection as per cl.4.26 IPX8 upto 1.3m |
8788 |
BLUESKY LAB LLP
| IS 10322 : PART 5 : SEC 3 (2012) |
Luminaires: Part 5 particular requirements: Sec 3 luminaires for road and street lighting (First Revision) |
- |
-
|
55000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
4(General Test Requireements) |
- |
500 |
|
10% discount offered to BIS |
5(Classification of Luminaires') |
- |
500 |
|
10% discount offered to BIS |
6.0(Marking) |
- |
1500 |
|
10% discount offered to BIS |
7.0(Construction) |
- |
8000 |
|
10% discount offered to BIS |
8.0(Creepage Distance and Clearances) |
- |
3000 |
|
10% discount offered to BIS |
9.0(Provision for earthing) |
- |
2500 |
|
10% discount offered to BIS |
10.0(Terminals) |
- |
2500 |
|
10% discount offered to BIS |
11.0(External & Internal Wiring) |
- |
5000 |
|
10% discount offered to BIS |
12.0(Protection against electric shock) |
- |
2500 |
|
10% discount offered to BIS |
13.0(Endurance Tests and Thermal Tests) |
- |
10000 |
|
10% discount offered to BIS |
14.0(Resistance to Dust & Moisture) |
- |
7000 |
|
10% discount offered to BIS |
15.0(Insulation Resistance and Electric Strength) |
- |
3000 |
|
10% discount offered to BIS |
16.0(Resistance to Heat , fire and tracking) |
- |
5000 |
|
10% discount offered to BIS |
17.0(Photometric Test) |
- |
25000 |
|
10% discount offered to BIS |
|
Complete
|
|
22 May, 2028 |
- Luminaries size restricted to 1000 mmfor photometric test, UV Radiations as per C. 4
.24 & Annex P of IS 10322 (Part 1):2014, Short-circuit protection as per cl.4.26 IPX8 upto 1.3m |
8789 |
BLUESKY LAB LLP
| IS 10322 : Part 5 : Sec 2 (2012) |
Luminaires: Part 5 particular requirements: Sec 2 recessed luminaires (First Revision) |
- |
-
|
55000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
4(General Test Requireements) |
- |
500 |
|
10% discount offered to BIS |
5(Classification of Luminaires') |
- |
500 |
|
10% discount offered to BIS |
6(Marking) |
- |
1500 |
|
10% discount offered to BIS |
7(Construction) |
- |
8000 |
|
10% discount offered to BIS |
8(Creepage Distance and Clearances) |
- |
3000 |
|
10% discount offered to BIS |
9(Provision for earthing) |
- |
2500 |
|
10% discount offered to BIS |
10(Terminals) |
- |
2500 |
|
10% discount offered to BIS |
11(External & Internal Wiring) |
- |
5000 |
|
10% discount offered to BIS |
12(Protection against electric shock) |
- |
2500 |
|
10% discount offered to BIS |
13(Endurance Tests and Thermal Tests) |
- |
10000 |
|
10% discount offered to BIS |
14(Resistance to Dust and Moisture) |
- |
7000 |
|
10% discount offered to BIS |
15(Insulation Resistance and Electric Strength) |
- |
3000 |
|
10% discount offered to BIS |
16(Resistance to Heat , fire and tracking) |
- |
5000 |
|
10% discount offered to BIS |
17(Photometric Test) |
- |
25000 |
|
10% discount offered to BIS |
|
Complete
|
|
22 May, 2028 |
- Luminaries size restricted to 1000 mm for photometric test, UV Radiations as per C. 4
.24 & Annex P of IS 10322 (Part 1):2014, Short-circuit protection as per cl.4.26 IPX8 upto 1.3m |
8790 |
BLUESKY LAB LLP
| IS 16102 : Part 1 (2012) |
Self - Ballasted led lamps for general lighting services: Part 1 safety requirements |
- |
-
|
40000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
5(Marking) |
- |
1500 |
|
10% discount offered to BIS |
6(Interchangeability) |
- |
3000 |
|
10% discount offered to BIS |
7(Protection against accidental contact with live parts) |
- |
2000 |
|
10% discount offered to BIS |
8(Insulation Resistance and Electric Strength) |
- |
10000 |
|
10% discount offered to BIS |
9(MECHANICAL STRENGTH) |
- |
2500 |
|
10% discount offered to BIS |
10(cap temperature) |
- |
5000 |
|
10% discount offered to BIS |
11(Resistance to Heat) |
- |
4000 |
|
10% discount offered to BIS |
12(Resistance to Flame and Ignition) |
- |
5500 |
|
10% discount offered to BIS |
13(Fault conditions) |
- |
6500 |
|
10% discount offered to BIS |
14(Creepage distance and clearances) |
- |
5500 |
|
10% discount offered to BIS |
Annex A(Ovreview of systems composed of LED modules and control gear) |
- |
400 |
|
10% discount offered to BIS |
Annex B(Lamps with operating position limitations) |
- |
400 |
|
10% discount offered to BIS |
15(Selection of lamps for tests (Sampling)) |
- |
500 |
|
10% discount offered to BIS |
16(Condition of compliance) |
- |
400 |
|
10% discount offered to BIS |
17(Tests) |
- |
200 |
|
10% discount offered to BIS |
|
Complete
|
|
22 May, 2028 |
- Restricted only to Cap type B22d, E14 & E27 |