| 9631 |
CEG Test House & Research Centre Private Limited, Jaipur
| 8119706
| IS 1786 (2008) |
High strength deformed steel bars and wires for concretere inforcement - Specification (Fourth Revision) |
Fe - 415, 415D, 415S, 500, 500D, 500S, 600, 650, 700 |
6300 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl 8.1(UTM) |
- |
6300 |
|
All Physical Test , Chemical Test |
| Cl 7.2(Weight) |
- |
1 |
|
NA |
| Cl 9.3(Load In One Direction) |
- |
1 |
|
NA |
| Cl 9.4(Load In Other Direction From Bend) |
- |
1 |
|
NA |
| Cl 9.3(Load In One Direction) |
- |
6300 |
|
Na |
| 4.1(CE) |
- |
6300 |
|
Na |
| Clause - 4.2 & 4.2.1(Fe- 415, Fe- 415D, Fe-500, Fe-500D, Fe-550, Fe-550D, Fe-600 CARBON ) |
- |
6300 |
|
Na |
| Cl 5(Deformations and Surface Characteristics) |
- |
1000 |
|
Na |
| Cl. 6.1(Nominal Size) |
- |
1000 |
|
Na |
| 7.1(Specified length) |
- |
1000 |
|
Na |
| Clause - 4.2 & 4.2.1(Fe- 415, Fe- 415D, Fe-500, Fe-500D, Fe-550, Fe-550D, Fe-600 SULPHUR) |
- |
1000 |
|
NA |
| Cl.4.2 of IS 1786 (Grade:- Fe 415,Fe 415D,Fe 415S,Fe 500,Fe 500D,Fe 500S,Fe 550,Fe 550D,Fe600,Fe 650,Fe 700)(Phosphorous- IS 228) |
- |
1000 |
|
NA |
| Cl. 5 (Cl.5 Mean area of ribs/unit length (Ar), ) |
- |
1000 |
|
Na |
| Cl. 5 (Cl. 5 - Mean projected area of transverse ribs (1/3 of Ar)) |
- |
1000 |
|
NA |
| 5.7(PullOut (Bond Test)) |
- |
1000 |
|
Na |
| Clause 6.3(Effective Cross-sectional Area) |
- |
1000 |
|
NA |
| Cl. 6.2, 6.3 Table 1(Gross Cross Sectional Area, A) |
- |
1000 |
|
Na |
| Cl. 8.1 Table 3(Yield Stress (YS)) |
- |
1000 |
|
Na |
| Cl. 8.1 Table 3(Elongation, percentage) |
- |
1000 |
|
Na |
| Cl. 8.1 Table 3(Tensile Strength (TS)) |
- |
1000 |
|
Na |
| Cl.4.2 of IS 1786 (Nickel- IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
1000 |
|
Na |
|
31 Dec, 2026 |
- Upto 32 mm only. Except Cr, Mn, Mo,V, N, Cu, Ni, Nb, B, Nb+V+B+Ti, AL |
| 9632 |
CEG Test House & Research Centre Private Limited, Jaipur
| 8119706
| IS 1237 (2012) |
Cement Concrete Flooring Tiles - Specification |
General Purpose & Heavy Duty Floor Tiles |
4500 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl 7.1(Length, Breadth, Minimum thickness, Difference in length of side between the longest side and shorterst side, Half tiles, Difference in Thickness between the thickest and thinnest tile, Thickness of wearing layer) |
- |
500 |
|
None |
| Cl 12.2(Concavity & Convexity ) |
- |
400 |
|
None |
| Cl 12.3(The Maximum gap between the arms of the square and the edge of the title shall notexceed 2 percent of the length.) |
- |
400 |
|
None |
| Cl 12.4(Shall not exceed 1 percent of the length of the edge.) |
- |
400 |
|
None |
| Cl 12.5(Water absorption) |
- |
500 |
|
None |
| Cl 12.6(Wet transverse strength ) |
- |
800 |
|
None |
| Cl 12.7(Resistance to wear) |
- |
1200 |
|
None |
| Cl 7.1(Length, Breadth, Minimum thickness, Difference in length of side between the longest side and shorterst side, Half tiles, Difference in Thickness between the thickest and thinnest tile, Thickness of wearing layer) |
- |
500 |
|
None |
| Cl 12.2(Concavity & Convexity ) |
- |
400 |
|
None |
| Cl 12.3(The Maximum gap between the arms of the square and the edge of the title shall notexceed 2 percent of the length.) |
- |
400 |
|
None |
| Cl 12.4(Shall not exceed 1 percent of the length of the edge.) |
- |
400 |
|
None |
| Cl 12.5(Water absorption) |
- |
500 |
|
None |
| Cl 12.6(Wet transverse strength ) |
- |
800 |
|
None |
| Cl 12.7(Resistance to wear) |
- |
1200 |
|
None |
| Cl 11(Suface Finish) |
- |
1200 |
|
None |
|
31 Dec, 2026 |
- - |
| 9633 |
CEG Test House & Research Centre Private Limited, Jaipur
| 8119706
| IS 1489 (Part 1) (2015) |
Portland pozzolana cement - Specification: Part 1 fly Ash Based |
Fly based |
8850 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 6 - Table - 1 i(Insoluble residue - Cl 7.4 of IS 4032:1985) |
- |
350 |
|
None |
| 6 - Table - 1 ii(Magnesia - Cl 7.2 of IS 4032:1985) |
- |
350 |
|
None |
| 6 - Table - 1 iii(Total Sulphur Content calculated as Sulphuric Anhydride (SO3) - Cl 7.3 of IS 4032:1985) |
- |
350 |
|
None |
| 6 - Table - 1 iv(Loss on ignition - Cl 7.1 of IS 4032:1985) |
- |
300 |
|
None |
| 6 - Table - 1 v(Chloride content - Cl 4.13 of IS 4032:1985) |
- |
350 |
|
None |
| 6 - Table - 1 vi( Alkali content as (Na2O + 0.658 K2O) - Cl 4.11 of IS 4032:1985) |
- |
350 |
|
None |
| 7 -Table 2- i(Fineness 4031 Part 2) |
- |
500 |
|
None |
| 7 -Table 2- ii- a(Expansion by Le Chatelier- 4031 Part 3) |
- |
500 |
|
None |
| 7 -Table 2- ii- b(Expansion by Autoclave- 4031 Part 3) |
- |
800 |
|
None |
| 7 -Table 2- iii- a(Setting Time Initial- 4031 Part 5) |
- |
400 |
|
None |
| 7 -Table 2-iii- b(Setting Time Final- 4031 Part 5) |
- |
400 |
|
None |
| 7 -Table 2- iv- a(Compressive Strength At 72 hrs ± 1 hr - IS 4031 Part 6) |
- |
1600 |
|
None |
| 7 -Table 2- iv- b(Compressive Strength At 168 hrs ± 2 hr - IS 4031 Part 6) |
- |
1600 |
|
None |
| 7 -Table 2- iv- c(Compressive Strength At 672 hrs ± 4 hr - IS 4031 Part 6) |
- |
1600 |
|
None |
| 7 -Table 2- v(Transverse Strength - IS 4031 Part 8 (Optional)) |
- |
1000 |
|
None |
| 7 -Table 2- vi(Drying Shrinkage- IS 4031 Part 10) |
- |
1500 |
|
None |
|
31 Dec, 2026 |
- - |
| 9634 |
CEG Test House & Research Centre Private Limited, Jaipur
| 8119706
| IS 1489 : Part 2 (2015) |
Portland - Pozzolana cement - Specification: Part 2 calcined clay based |
Calcined Clay Based |
8850 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 6 - Table - 1 i(Insoluble residue - Cl 7.4 of IS 4032:1985) |
- |
350 |
|
None |
| 6 - Table - 1 ii(Magnesia - Cl 7.2 of IS 4032:1985) |
- |
350 |
|
None |
| 6 - Table - 1 iii(Total Sulphur Content calculated as Sulphuric Anhydride (SO3) - Cl 7.3 of IS 4032:1985) |
- |
350 |
|
None |
| 6 - Table - 1 iv(Loss on ignition - Cl 7.1 of IS 4032:1985) |
- |
300 |
|
None |
| 6 - Table - 1 v(Chloride content - Cl 4.13 of IS 4032:1985) |
- |
350 |
|
None |
| 6 - Table - 1 vi( Alkali content as (Na2O + 0.658 K2O) - Cl 4.11 of IS 4032:1985) |
- |
350 |
|
None |
| 7 -Table 2- i(Fineness 4031 Part 2) |
- |
500 |
|
None |
| 7 -Table 2- ii- a(Expansion by Le Chatelier- 4031 Part 3) |
- |
500 |
|
None |
| 7 -Table 2- ii- b(Expansion by Autoclave- 4031 Part 3) |
- |
800 |
|
None |
| 7 -Table 2- iii- a(Setting Time Initial- 4031 Part 5) |
- |
400 |
|
None |
| 7 -Table 2-iii- b(Setting Time Final- 4031 Part 5) |
- |
400 |
|
None |
| 7 -Table 2- iv- a(Compressive Strength At 72 hrs ± 1 hr - IS 4031 Part 6) |
- |
1600 |
|
None |
| 7 -Table 2- iv- b(Compressive Strength At 168 hrs ± 2 hr - IS 4031 Part 6) |
- |
1600 |
|
None |
| 7 -Table 2- iv- c(Compressive Strength At 672 hrs ± 4 hr - IS 4031 Part 6) |
- |
1600 |
|
None |
| 7 -Table 2- v(Transverse Strength - IS 4031 Part 8 (Optional)) |
- |
1000 |
|
None |
| 7 -Table 2- vi(Drying Shrinkage- IS 4031 Part 10) |
- |
1500 |
|
None |
|
31 Dec, 2026 |
- - |
| 9635 |
CEG Test House & Research Centre Private Limited, Jaipur
| 8119706
| IS 383 (2016) |
Coarse and Fine Aggregate for Concrete - Specification (Third Revision) |
Coarse & Fine |
13100 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 6.1-Table 7(SIZE AND GRADING OF AGGREGATES-Single-Sized Coarse Aggregates-Nominal Size of aggregate) |
- |
6000 |
|
All Chemical,Grading, EI, FI Test |
| 5.4.1 (a)(mechanical properties- Aggregate Crushing Value/Ten Percent Fines Value) |
- |
1000 |
|
NA |
| 5.4.1 (b)(mechanical properties- Aggregate Crushing Value/Ten Percent Fines Value) |
- |
1000 |
|
NA |
| 5.4.2(a)( Aggregates Impact Value) |
- |
1000 |
|
NA |
| 5.4.3(a)( Aggregate Abrasion Value) |
- |
2000 |
|
Water Absorption, Specific Gravity and Abrasion |
| Clause 5.1(General) |
- |
800 |
|
Na |
| 5.2- TABLE-2- (Note-4) IS-2386 (P-2)(Organic impurities (fine aggregate)) |
- |
800 |
|
Na |
| 5.2- TABLE-2- (vi) IS-2386 (P-2)(Total deleterious material (fine aggregate)) |
- |
800 |
|
Na |
| 5.2- TABLE-2- (iii) IS-2386 (P-1)(Material fine aggregater than 75 micron (fine aggregate)) |
- |
800 |
|
NA |
| 5.2- TABLE-2- (ii) IS-2386 (P-2)(Clay lumps (fine aggregate )) |
- |
800 |
|
NA |
| 5.2- TABLE-2- (i) IS-2386 (P-2)(Coal and Lignite (fine aggregate )) |
- |
800 |
|
NA |
| 5.4.2(b)( Aggregates Impact Value) |
- |
800 |
|
NA |
| 5.4.3(b)( Aggregate Abrasion Value) |
- |
800 |
|
NA |
| 5.5 Na2so4/5.5.1 Maso4/5.5.1 (Soundness) |
- |
800 |
|
NA |
| 5.6(Alkali Agregate Reaction ) |
- |
800 |
|
NA |
| Clause 5.6(Dissolved Silica) |
- |
800 |
|
NA |
| Clause 5.6(Reduction in Alkalinity) |
- |
800 |
|
NA |
| 5.7-Table-3-(Iv) IS: 2386 (P-3)(Water absorption (coarse aggregate)) |
- |
800 |
|
NA |
| 5.3-IS: 2386 (P-1)(Combined elongation & flakiness index (coarse aggregate)) |
- |
800 |
|
NA |
| Table 6 Cl. 5.7 (iv)() |
- |
800 |
|
Na |
| 6.3-Table 9(i)(SIZE AND GRADING OF AGGREGATES-Fine Aggregate-Percentage Passing through 10mm Sieve ) |
- |
800 |
|
Na |
| 6.3-Table 9(SIZE AND GRADING OF AGGREGATES-Fine Aggregate-Grading Zone) |
- |
800 |
|
Na |
| 6.4-Table 10(SIZE AND GRADING OF AGGREGATES- All-in-Aggregate Grading-Nominal Size ) |
- |
800 |
|
NA |
| 5.7-Table-3-(v) IS: 2386 (P-3)(specific gravity(coarse aggregate)) |
- |
700 |
|
NA |
| 5.7-Table-3-(II) IS:4032(Total sulphate content (fine aggregate)) |
- |
700 |
|
NA |
| 5.7-Table-3-(III) IS:14959 (P-2)(Water soluble chloride content (fine aggregate)) |
- |
700 |
|
NA |
| Clause 5.7- Table 3 (i) (TotalAlkali content as Na2O equivalent ) |
- |
700 |
|
NA |
| 5.2 (5.2.2, 5.2.1, 5.2.3, shale table-2 ) (Deleterious material (Clay lumps, coal & lignite, material finer than 75 micron IS sieve, Soft fragments,shale)) |
- |
700 |
|
Na |
| 6.1.1-Table 8(SIZE AND GRADING OF AGGREGATES- Sizes of Coarse Aggregates for Mass Concrete- Class) |
- |
700 |
|
Na |
|
31 Dec, 2026 |
- Scope restricted to aggregates from natural resourcs only
Exclusion: Petrographic analysis test) |
| 9636 |
CEG Test House & Research Centre Private Limited, Jaipur
| 8119706
| IS 8887 (2018) |
Bitumen emulsion for roads (Cationic Type) - Specification (Third Revision) |
RS-1, RS-2, MS, SS-1, SS-2 |
11000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 6.6.2 Table-1; 1(i)(Residue on 600 micron IS Sieve, (Grad RS-1) IS 8, Annex 9) |
- |
700 |
|
Rate applicable for all grades |
| 6.6.2 Table-1; 1(i)(Residue on 600 micron IS Sieve, (Grad RS-2) Annex 9) |
- |
700 |
|
Rate applicable for all grades |
| 6.6.2 Table-1; 1(i)(Residue on 600 micron IS Sieve, (Grad MS) Annex 9) |
- |
700 |
|
Rate applicable for all grades |
| 6.6.2 Table-1; 1(i)(Residue on 600 micron IS Sieve, (Grad SS-1) Annex 9) |
- |
700 |
|
Rate applicable for all grades |
| 6.6.2 Table-1; 1(i)(Residue on 600 micron IS Sieve, (Grad SS-2) Annex 9) |
- |
700 |
|
Rate applicable for all grades |
| 6.6.2 Table-1; 1(ii) (1)(Viscosity by saybolt furol viscometer, seconds (Grad RS-1), IS 3117) |
- |
700 |
|
Rate applicable for all grades |
| 6.6.2 Table-1; 1(ii) (1)(Viscosity by saybolt furol viscometer, seconds (Grad RS-2) |
- |
700 |
|
Rate applicable for all grades |
| 6.6.2 Table-1; 1(ii) (1)(Viscosity by saybolt furol viscometer, seconds (Grad MS), IS 3117) |
- |
700 |
|
Rate applicable for all grades |
| 6.6.2 Table-1; 1(ii) (1)(Viscosity by saybolt furol viscometer, seconds (Grad SS-1), IS 3117) |
- |
700 |
|
Rate applicable for all grades |
| 6.6.2 Table-1; 1(ii) (1)(Viscosity by saybolt furol viscometer, seconds (Grad SS-2), IS 3117) |
- |
700 |
|
Rate applicable for all grades |
| 6.6.2 Table-1; 1(ii) (2)(Viscosity by saybolt furol viscometer, seconds (Grad RS-1), IS 3117) |
- |
700 |
|
Rate applicable for all grades |
| 6.6.2 Table-1; 1(ii) (2)(Viscosity by saybolt furol viscometer, seconds (Grad RS-2, IS 3117) |
- |
700 |
|
Rate applicable for all grades |
| 6.6.2 Table-1; 1(ii) (2)(Viscosity by saybolt furol viscometer, seconds (Grad MS), IS 3117) |
- |
700 |
|
Rate applicable for all grades |
| 6.6.2 Table-1; 1(ii) (2)(Viscosity by saybolt furol viscometer, seconds (Grad SS-1), IS 3117) |
- |
700 |
|
Rate applicable for all grades |
| 6.6.2 Table-1; 1(ii) (2)(Viscosity by saybolt furol viscometer, seconds (Grad SS-2), IS 3117) |
- |
700 |
|
Rate applicable for all grades |
| 6.6.2 Table-1; 1(iii)(Coagulation of emulsion at low temperature (Grad RS-1), Annex C) |
- |
800 |
|
Rate applicable for all grades |
| 6.6.2 Table-1; 1(iii)(Coagulation of emulsion at low temperature (Grad RS-2), Annex C) |
- |
800 |
|
Rate applicable for all grades |
| 6.6.2 Table-1; 1(iii)(Coagulation of emulsion at low temperature (Grad MS), Annex C) |
- |
800 |
|
Rate applicable for all grades |
| 6.6.2 Table-1; 1(iii)(Coagulation of emulsion at low temperature (Grad SS-1), Annex C) |
- |
800 |
|
Rate applicable for all grades |
| 6.6.2 Table-1; 1(iii)(Coagulation of emulsion at low temperature (Grad SS-2), Annex C) |
- |
800 |
|
Rate applicable for all grades |
| 6.6.2 Table-1; 1(iv)(Storage stability after 24 h (Grad RS-1), Annex D) |
- |
800 |
|
Rate applicable for all grades |
| 6.6.2 Table-1; 1(iv)(Storage stability after 24 h (Grad RS-2), Annex D) |
- |
800 |
|
Rate applicable for all grades |
| 6.6.2 Table-1; 1(iv)(Storage stability after 24 h (Grade MS), Annex D) |
- |
800 |
|
Rate applicable for all grades |
| 6.6.2 Table-1; 1(iv)(Storage stability after 24 h (Grade SS-1), Annex D) |
- |
800 |
|
Rate applicable for all grades |
| 6.6.2 Table-1; 1(iv)(Storage stability after 24 h (Grade SS-2), Annex D) |
- |
800 |
|
Rate applicable for all grades |
| 6.6.2 Table-1; 1(v)(Particle charge (Grad RS-1), Annex E) |
- |
800 |
|
Rate applicable for all grades |
| 6.6.2 Table-1; 1(v)(Particle charge (Grad RS-2), Annex E) |
- |
800 |
|
Rate applicable for all grades |
| 6.6.2 Table-1; 1(v)(Particle charge (Grad MS), Annex E) |
- |
800 |
|
Rate applicable for all grades |
| 6.6.2 Table-1; 1(v)(Particle charge (Grad SS-1), Annex E) |
- |
800 |
|
Rate applicable for all grades |
| 6.6.2 Table-1; 1(v)(Particle charge (Grad SS-2), Annex E) |
- |
800 |
|
Rate applicable for all grades |
| 6.6.2 Table-1; 1(vi) 1(Coating ability and water resistance:
Coating, dry aggregate (Grade RS-1) Annex F) |
- |
800 |
|
Rate applicable for all grades |
| 6.6.2 Table-1; 1(vi) 1(Coating ability and water resistance:
Coating, dry aggregate (Grade RS-2) Annex F) |
- |
800 |
|
Rate applicable for all grades |
| 6.6.2 Table-1; 1(vi) 1(Coating ability and water resistance:
Coating, dry aggregate (Grade MS) Annex F) |
- |
800 |
|
Rate applicable for all grades |
| 6.6.2 Table-1; 1(vi) 1(Coating ability and water resistance:
Coating, dry aggregate (Grade SS-1) Annex F) |
- |
800 |
|
Rate applicable for all grades |
| 6.6.2 Table-1; 1(vi) 1(Coating ability and water resistance:
Coating, dry aggregate (Grade SS-2) Annex F) |
- |
800 |
|
Rate applicable for all grades |
| 6.6.2 Table-1; 1(vi) 2(Coating ability and water resistance:
Coating, after spraying (Grade RS-1) Annex F) |
- |
800 |
|
Rate applicable for all grades |
| 6.6.2 Table-1; 1(vi) 2(Coating ability and water resistance:
Coating, after spraying (Grade RS-2) Annex F) |
- |
800 |
|
Rate applicable for all grades |
| 6.6.2 Table-1; 1(vi) 2(Coating ability and water resistance:
Coating, after spraying (Grade MS) Annex F) |
- |
800 |
|
Rate applicable for all grades |
| 6.6.2 Table-1; 1(vi) 2(Coating ability and water resistance:
Coating, after spraying (Grade SS-1) Annex F) |
- |
800 |
|
Rate applicable for all grades |
| 6.6.2 Table-1; 1(vi) 2(Coating ability and water resistance:
Coating, after spraying (Grade SS-2) Annex F) |
- |
800 |
|
Rate applicable for all grades |
| 6.6.2 Table-1; 1(vi) 3(Coating ability and water resistance:
Coating, wet aggregate (Grade RS-1) Annex F) |
- |
800 |
|
Rate applicable for all grades |
| 6.6.2 Table-1; 1(vi) 3(Coating ability and water resistance:
Coating, wet aggregate (Grade RS-2) Annex F) |
- |
800 |
|
Rate applicable for all grades |
| 6.6.2 Table-1; 1(vi) 3(Coating ability and water resistance:
Coating, wet aggregate (Grade MS) Annex F) |
- |
800 |
|
Rate applicable for all grades |
| 6.6.2 Table-1; 1(vi) 3(Coating ability and water resistance:
Coating, wet aggregate (Grade SS-1) Annex F) |
- |
800 |
|
Rate applicable for all grades |
| 6.6.2 Table-1; 1(vi) 3(Coating ability and water resistance:
Coating, wet aggregate (Grade SS-2) Annex F) |
- |
800 |
|
Rate applicable for all grades |
| 6.6.2 Table-1; 1(vi) 4(Coating ability and water resistance:
Coating, After Spraying (Grade RS-1) Annex F) |
- |
800 |
|
Rate applicable for all grades |
| 6.6.2 Table-1; 1(vi) 4(Coating ability and water resistance:
Coating, After Spraying (Grade RS-2) Annex F) |
- |
800 |
|
Rate applicable for all grades |
| 6.6.2 Table-1; 1(vi) 4(Coating ability and water resistance:
Coating, After Spraying (Grade MS) Annex F) |
- |
800 |
|
Rate applicable for all grades |
| 6.6.2 Table-1; 1(vi) 4(Coating ability and water resistance:
Coating, After Spraying (Grade SS-1) Annex F) |
- |
800 |
|
Rate applicable for all grades |
| 6.6.2 Table-1; 1(vi) 4(Coating ability and water resistance:
Coating, After Spraying (Grade SS-2) Annex F) |
- |
800 |
|
Rate applicable for all grades |
| 6.6.2 Table-1; 1(vii)(Stability to mixing with cement (Grade RS-1) Annex G) |
- |
700 |
|
Rate applicable for all grades |
| 6.6.2 Table-1; 1(vii)(Stability to mixing with cement (Grade RS-2) Annex G) |
- |
700 |
|
Rate applicable for all grades |
| 6.6.2 Table-1; 1(vii)(Stability to mixing with cement (Grade MS) Annex G) |
- |
700 |
|
Rate applicable for all grades |
| 6.6.2 Table-1; 1(vii)(Stability to mixing with cement (Grade SS-1) Annex G) |
- |
700 |
|
Rate applicable for all grades |
| 6.6.2 Table-1; 1(vii)(Stability to mixing with cement (Grade SS-2) Annex G) |
- |
700 |
|
Rate applicable for all grades |
| 6.6.2 Table-1; 1(viii)(Miscibility with water (Grade RS-1) Annex H) |
- |
500 |
|
Rate applicable for all grades |
| 6.6.2 Table-1; 1(viii)(Miscibility with water (Grade RS-2) Annex H) |
- |
500 |
|
Rate applicable for all grades |
| 6.6.2 Table-1; 1(viii)(Miscibility with water (Grade MS) Annex H) |
- |
500 |
|
Rate applicable for all grades |
| 6.6.2 Table-1; 1(viii)(Miscibility with water (Grade SS-1) Annex H) |
- |
500 |
|
Rate applicable for all grades |
| 6.6.2 Table-1; 1(viii)(Miscibility with water (Grade SS-2) Annex H) |
- |
500 |
|
Rate applicable for all grades |
| 6.6.2 Table-1; 1(ix) 1(Tests on residue: Residue by evaporation (Grade RS-1) Annex J) |
- |
800 |
|
Rate applicable for all grades |
| 6.6.2 Table-1; 1(ix) 1(Tests on residue: Residue by evaporation (Grade RS-2) Annex J) |
- |
800 |
|
Rate applicable for all grades |
| 6.6.2 Table-1; 1(ix) 1(Tests on residue: Residue by evaporation (Grade MS) Annex J) |
- |
800 |
|
Rate applicable for all grades |
| 6.6.2 Table-1; 1(ix) 1(Tests on residue: Residue by evaporation (Grade SS-1) Annex J) |
- |
800 |
|
Rate applicable for all grades |
| 6.6.2 Table-1; 1(ix) 1(Tests on residue: Residue by evaporation (Grade SS-2) Annex J) |
- |
800 |
|
Rate applicable for all grades |
| 6.6.2 Table-1; 1(ix) 2(Tests on residue: Penetration (Grade RS-1) IS 1203) |
- |
800 |
|
Rate applicable for all grades |
| 6.6.2 Table-1; 1(ix) 2(Tests on residue: Penetration (Grade RS-2) IS 1203) |
- |
800 |
|
Rate applicable for all grades |
| 6.6.2 Table-1; 1(ix) 2(Tests on residue: Penetration (Grade MS) IS 1203) |
- |
800 |
|
Rate applicable for all grades |
| 6.6.2 Table-1; 1(ix) 2(Tests on residue: Penetration (Grade SS-1) IS 1203) |
- |
800 |
|
Rate applicable for all grades |
| 6.6.2 Table-1; 1(ix) 2(Tests on residue: Penetration (Grade SS-2) IS 1203) |
- |
800 |
|
Rate applicable for all grades |
| 6.6.2 Table-1; 1(ix) 3(Tests on residue: Ductility (Grade RS-1) IS 1208) |
- |
800 |
|
Rate applicable for all grades |
| 6.6.2 Table-1; 1(ix) 3(Tests on residue: Ductility (Grade RS-2) IS 1208) |
- |
800 |
|
Rate applicable for all grades |
| 6.6.2 Table-1; 1(ix) 3(Tests on residue: Ductility (Grade MS) IS 1208) |
- |
800 |
|
Rate applicable for all grades |
| 6.6.2 Table-1; 1(ix) 3(Tests on residue: Ductility (Grade SS-1) IS 1208) |
- |
800 |
|
Rate applicable for all grades |
| 6.6.2 Table-1; 1(ix) 3(Tests on residue: Ductility (Grade SS-2) IS 1208) |
- |
800 |
|
Rate applicable for all grades |
| 6.6.2 Table-1; 1(ix) 4(Tests on residue: Solubility I tricholoethylne,
(Grade RS-1) IS 1216) |
- |
600 |
|
Rate applicable for all grades |
| 6.6.2 Table-1; 1(ix) 4(Tests on residue: Solubility I tricholoethylne,
(Grade RS-2) IS 1216) |
- |
600 |
|
Rate applicable for all grades |
| 6.6.2 Table-1; 1(ix) 4(Tests on residue: Solubility I tricholoethylne,
(Grade MS) IS 1216) |
- |
600 |
|
Rate applicable for all grades |
| 6.6.2 Table-1; 1(ix) 4(Tests on residue: Solubility I tricholoethylne,
(Grade SS-1) IS 1216) |
- |
600 |
|
Rate applicable for all grades |
| 6.6.2 Table-1; 1(ix) 4(Tests on residue: Solubility I tricholoethylne,
(Grade SS-2) IS 1216) |
- |
600 |
|
Rate applicable for all grades |
| 6.6.2 Table-1; 1(x) 1(Distillation in percent volume of distillate recovered at 360°C (Grade RS-1)) |
- |
500 |
|
Rate applicable for all grades |
| 6.6.2 Table-1; 1(x) 1(Distillation in percent volume of distillate recovered at 360°C (Grade RS-2)) |
- |
500 |
|
Rate applicable for all grades |
| 6.6.2 Table-1; 1(x) 1(Distillation in percent volume of distillate recovered at 360°C (Grade MS)) |
- |
500 |
|
Rate applicable for all grades |
| 6.6.2 Table-1; 1(x) 1(Distillation in percent volume of distillate recovered at 360°C (SS-1)) |
- |
500 |
|
Rate applicable for all grades |
| 6.6.2 Table-1; 1(x) 1(Distillation in percent volume of distillate recovered at 360°C (Grade SS-2)) |
- |
500 |
|
Rate applicable for all grades |
| 6.6.2 Table-1; 1(x) 2(Distillation in percent volume of distillate recovered at 360°C (Grade RS-1)) |
- |
500 |
|
Rate applicable for all grades |
| 6.6.2 Table-1; 1(x) 2(Distillation in percent volume of distillate recovered at 360°C (Grade RS-2)) |
- |
500 |
|
Rate applicable for all grades |
| 6.6.2 Table-1; 1(x) 2(Distillation in percent volume of distillate recovered at 360°C (Grade MS)) |
- |
500 |
|
Rate applicable for all grades |
| 6.6.2 Table-1; 1(x) 2(Distillation in percent volume of distillate recovered at 360°C (SS-1)) |
- |
500 |
|
Rate applicable for all grades |
| 6.6.2 Table-1; 1(x) 2(Distillation in percent volume of distillate recovered at 360°C (Grade SS-2)) |
- |
500 |
|
Rate applicable for all grades |
| 6.6.2 Table-1; 1(x) 3(Distillation in percent volume of distillate recovered at 360°C (Grade RS-1)) |
- |
500 |
|
Rate applicable for all grades |
| 6.6.2 Table-1; 1(x) 3(Distillation in percent volume of distillate recovered at 360°C (Grade RS-2)) |
- |
500 |
|
Rate applicable for all grades |
| 6.6.2 Table-1; 1(x) 3(Distillation in percent volume of distillate recovered at 360°C (Grade MS)) |
- |
500 |
|
Rate applicable for all grades |
| 6.6.2 Table-1; 1(x) 3(Distillation in percent volume of distillate recovered at 360°C (SS-1)) |
- |
500 |
|
Rate applicable for all grades |
| 6.6.2 Table-1; 1(x) 3(Distillation in percent volume of distillate recovered at 360°C (Grade SS-2)) |
- |
500 |
|
Rate applicable for all grades |
| 6.6.2 Table-1; 1(x) 4(Distillation in percent volume of distillate recovered at 360°C (Grade RS-1)) |
- |
500 |
|
Rate applicable for all grades |
| 6.6.2 Table-1; 1(x) 4(Distillation in percent volume of distillate recovered at 360°C (Grade RS-2)) |
- |
500 |
|
Rate applicable for all grades |
| 6.6.2 Table-1; 1(x) 4(Distillation in percent volume of distillate recovered at 360°C (Grade MS)) |
- |
500 |
|
Rate applicable for all grades |
| 6.6.2 Table-1; 1(x) 4(Distillation in percent volume of distillate recovered at 360°C (SS-1)) |
- |
500 |
|
Rate applicable for all grades |
| 6.6.2 Table-1; 1(x) 4(Distillation in percent volume of distillate recovered at 360°C (Grade SS-2)) |
- |
500 |
|
Rate applicable for all grades |
| 6.6.2 Table-1; 1(x) 5(Distillation in percent volume of distillate recovered at 360°C (Grade RS-1)) |
- |
500 |
|
Rate applicable for all grades |
| 6.6.2 Table-1; 1(x) 5(Distillation in percent volume of distillate recovered at 360°C (Grade RS-2)) |
- |
500 |
|
Rate applicable for all grades |
| 6.6.2 Table-1; 1(x) 5(Distillation in percent volume of distillate recovered at 360°C (Grade MS)) |
- |
500 |
|
Rate applicable for all grades |
| 6.6.2 Table-1; 1(x) 5(Distillation in percent volume of distillate recovered at 360°C (SS-1)) |
- |
500 |
|
Rate applicable for all grades |
| 6.6.2 Table-1; 1(x) 5(Distillation in percent volume of distillate recovered at 360°C (Grade SS-2)) |
- |
500 |
|
Rate applicable for all grades |
| 6.6.2 Table-1; 1(xi)(Water content (Grade RS-1)) |
- |
500 |
|
Rate applicable for all grades |
| 6.6.2 Table-1; 1(xi)(Water content (Grade RS-2)) |
- |
500 |
|
Rate applicable for all grades |
| 6.6.2 Table-1; 1(xi)(Water content (Grade MS)) |
- |
500 |
|
Rate applicable for all grades |
| 6.6.2 Table-1; 1(xi)(Water content (Grade SS-1)) |
- |
500 |
|
Rate applicable for all grades |
| 6.6.2 Table-1; 1(xi)(Water content (Grade SS-2)) |
- |
500 |
|
Rate applicable for all grades |
| 6.6.2 Table-1; 1(i)(Residue on 600 micron IS Sieve, (Grad SS-1) Annex 9) |
- |
700 |
|
Rate applicable for all grades. |
| 6.6.2 Table-1; 1(i)(Residue on 600 micron IS Sieve, (Grad SS-2) Annex 9) |
- |
700 |
|
Rate applicable for all grades. |
| 6.6.2 Table-1; 1(iv)(Storage stability after 24 h (Grad RS-1), Annex D) |
- |
800 |
|
Rate applicable for all grades. |
| 6.6.2 Table-1; 1(iv)(Storage stability after 24 h (Grad RS-2), Annex D) |
- |
800 |
|
Rate applicable for all grades. |
| 6.6.2 Table-1; 1(iv)(Storage stability after 24 h (Grade SS-1), Annex D) |
- |
800 |
|
Rate applicable for all grades. |
| 6.6.2 Table-1; 1(iv)(Storage stability after 24 h (Grade SS-2), Annex D) |
- |
800 |
|
Rate applicable for all grades. |
| CL: 4.4.1(Material For all grades) |
- |
800 |
|
Rate applicable for all grades. |
|
31 Dec, 2026 |
- - |
| 9637 |
CEG Test House & Research Centre Private Limited, Jaipur
| 8119706
| IS 269 (2015) |
Ordinary portland cement - Specification (Sixth Revision) |
33, 43, 53, 43S, 53S |
11000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 6.1 Table-2 i.(Ratio of percentage of lime to percentage of silica, alumina and iron oxide) |
- |
700.00 |
|
Silica and Calcium, Rs 350.00 each |
| 6.1 Table-2 ii.(Ratio of percentage of alumina to that of iron oxide) |
- |
700.00 |
|
Alumina and Iron OXide, Rs 350.00 each |
| 6.1 Table-2 iii.(Insoluble residue) |
- |
350.00 |
|
None |
| 6.1 Table-2 iv(Magnesia) |
- |
350.00 |
|
None |
| 6.1 Table-2 v(Total Sulphur Content calculated as Sulphuric Anhydride) |
- |
350.00 |
|
None |
| 6.1 Table-2 vi(Loss on ignition) |
- |
300.00 |
|
None |
| 6.1 Table-2 vii(Chloride content) |
- |
350.00 |
|
None |
| 6.1 Table-2 viii(Alkali content) |
- |
350.00 |
|
None |
| 7 Table-3 i.(Fineness) |
- |
500.00 |
|
None |
| 7 Table-3 ii a(Expansion by Le Chatelier) |
- |
1000.00 |
|
500 - Expansion
500 - Consistency required for Expansion parameter as per Ref. Clause 6.3 |
| 7 Table-3 ii b(Expansion by Autoclave) |
- |
800.00 |
|
None |
| 7 Table-3 iii a(Setting Time Initial) |
- |
400.00 |
|
None |
| 7 Table-3 iii b(Setting Time Final) |
- |
400.00 |
|
None |
| 7 Table-3 iv a(Compressive Strength At 72 hrs ± 1 hr - IS 4031 Part 6) |
- |
2500.00 |
|
Rs 2500 charges for all three time frequency |
| 7 Table-3 iv b(Compressive Strength At 168 hrs ± 2 hr - IS 4031 Part 6) |
- |
2500.00 |
|
Rs 2500 charges for all three time frequency |
| 7 Table-3 iv c(Compressive Strength At 672 hrs ± 4 hr - IS 4031 Part 6) |
- |
2500.00 |
|
Rs 2500 charges for all three time frequency |
| 7 Table-3 v(Transverse Strength - IS 4031 Part 8 (Optional)) |
- |
1000 |
|
none |
|
31 Dec, 2026 |
- - |
| 9638 |
Excel Surveyors Pvt. Ltd., Kolkata
| 5135906
| IS 15138 (2010) |
Textiles – Jute bags for packing 50 kg sugar – Specification (first revision) |
All facility available |
1950 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4.1(Fabric) |
- |
200 |
|
Not Applicable. |
| 4.2
IS 9113(Seam
) |
- |
100 |
|
Not Applicable. |
| 5,5.1
Table 1(SPECIFIC REQUIREMENTS) |
- |
100 |
|
Not Applicable. |
| 5,5.1,5.2
Table 1,ii)
Cl.8.4.2 of IS 9113
Table A / B / C(Ends/dm) |
- |
50 |
|
Not Applicable. |
| 5,5.1,5.2
Table 1,iii)
Cl.8.4.2 of IS 9113
Table A / B / C(Picks/dm) |
- |
50 |
|
Not Applicable. |
| 5,5.1,5.2
Table 1,iv)
Cl.8.5.2 of IS 9113
Table A / B / C(Corrected mass per bag) |
- |
200 |
|
Not Applicable. |
| 5,5.1,5.2
Table 1,v) a)
Cl.8.6.2 of IS 9113
Table A / B / C(Average breaking load of sacking (ravelled strip method, 5.0 cm × 20.0 cm), Min, N (kgf)
Warpway:) |
- |
200 |
|
Not Applicable. |
| 5,5.1,5.2
Table 1,v) b)
Cl.8.6.2 of IS 9113
Table A / B / C(Average breaking load of sacking (ravelled stripmethod, 5.0 cm × 20.0 cm), Min, N (kgf)
Weftway :) |
- |
200 |
|
Not Applicable. |
| 5,5.1,5.2
Table 1,vi) a)
Cl.8.7 of IS 9113
Table A / B / C( Average breaking load of sacking (ravelled stripmethod, 5.0 cm × 20.0 cm), Min, N (kgf)
Warpway:) |
- |
200 |
|
Not Applicable. |
| 5,5.1,5.2
Table 1,vii)a)
Cl.8.2 of IS 9113
Table A / B / C(Moisture regain) |
- |
250 |
|
Not Applicable. |
| 5.3
(SPECIFIC REQUIREMENTS) |
- |
400 |
|
Not Applicable. |
|
31 Dec, 2026 |
- - |
| 9639 |
Excel Surveyors Pvt. Ltd., Kolkata
| 5135906
| IS 16186 (2014) |
Textiles - Light weight jute sacking bags for packing 50 kg foodgrains - Specification |
- |
1800 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4.2.iii)( Stitches/dm 10 ± 1 ) |
- |
50 |
|
Not Applicable. |
| 4.3.i)( Stitches/dm 10 ± 1 ) |
- |
50 |
|
Not Applicable. |
| 4.5(Freedom from defects) |
- |
50 |
|
Not Applicable. |
| 4.1 & 5.1, Table 1(Dimension-IS 9113 (Cl.8.3.2)) |
- |
100 |
|
Not Applicable. |
| 4.1 & 5.1, Table 1(Ends /dm-IS 9113 (Cl.8.4.2)) |
- |
50 |
|
Not Applicable. |
| 4.1 & 5.1, Table 1(Picks/dm-IS 9113 (Cl.8.4.2)) |
- |
50 |
|
Not Applicable. |
| 4.1 & 5.1, Table 1(Corrected Mass/Bag,g-IS 9113 (Cl.8.5.2)) |
- |
200 |
|
Not Applicable. |
| 4.1 & 5.1, Table 1(Average Breaking Strength in N) |
- |
400 |
|
Not Applicable. |
| 4.1 & 5.1, Table 1(Average Seam Strength in N-IS 9113 (Cl.8.7)) |
- |
200 |
|
Not Applicable. |
| 4.1 & 5.1, Table 1(Moisture Regain, Percent-IS 9113 (Cl.8.2)) |
- |
250 |
|
Not Applicable. |
| 4.1 & 5.1, Table 1(Oil content, Percent-IS 9113 (Cl.8.5.2)) |
- |
400 |
|
Not Applicable. |
| 4.1(i)The bags shall be made from single piece of 2/1 twill weave jute sacking of uniform construction with warp running along the length of the bag. ) |
- |
- |
|
- |
| 4.1(Fabric) |
- |
- |
|
- |
| 4.1(ii) The mass per square meter of sacking used in the fabric of the bag 504 g.) |
- |
- |
|
- |
| 4.2(Seam-IS 9113 (Cl.5.1.2)) |
- |
- |
|
- |
| 4.4(Hemming at the mouth-IS 9113 (Cl.5.1.2)) |
- |
- |
|
- |
|
31 Dec, 2026 |
- Exclusion: Specific requirements for Eco mark (Table-3, Cl.5.4.2.1) |
| 9640 |
Excel Surveyors Pvt. Ltd., Kolkata
| 5135906
| IS 16208 (2015) |
Textiles - High density polyethylene (HDPE)/polypropylene (PP) woven sacks for packaging 10 kg, 15 kg, 20 kg, 25 kg and 30 kg foodgrains - Specification |
Raw Materials (Identification of Polymer) (Cl. 4.1) |
5900 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4.2(Tapes – Width
IS 6192 and IS 11197) |
- |
50 |
|
Not Applicable |
| 4.3.1(Bottom Seam) |
- |
50 |
|
Not Applicable |
| 4.3.1(Bottom Seam) |
- |
50 |
|
Not Applicable |
| 4.3.2(Mouth) |
- |
50 |
|
Not Applicable |
| 5.2 and Table 1 ii a(Dimensions Inside Length) |
- |
50 |
|
Not Applicable |
| 5.2 and Table 1 ii b(Dimensions Inside Width) |
- |
50 |
|
Not Applicable |
| 5.2 and Table 1 iii(Ends per dm ) |
- |
50 |
|
Not Applicable |
| 5.2 and Table 1 iv(Picks per dm ) |
- |
50 |
|
Not Applicable |
| 5.1 and Table 1 v(Mass of sack ) |
- |
200 |
|
Not Applicable |
| 5.2 and Table 1 vi a(Average breaking strength of fabric Lengthwise ) |
- |
200 |
|
Not Applicable |
| 5.2 and Table 1 vi b(Average breaking strength of fabric Widthwise ) |
- |
200 |
|
Not Applicable |
| 5.2 and Table 1 vi(Breaking strength of bottom seam ) |
- |
200 |
|
Not Applicable |
| 5.2 and Table 1 viii a(Elongation at break of fabric Lengthwise) |
- |
50 |
|
Not Applicable |
| 5.2 and Table 1 viii b(Elongation at break of fabric Widthwise ) |
- |
50 |
|
Not Applicable |
| 5.2 and Table 1 ix(Average breaking strength and elongation at break of UV stabilized HDPE/PP fabric after been exposed to UV radiation and weathering ) |
- |
4200 |
|
Not Applicable |
| 5.2 and Table 1 x(Ash content ) |
- |
400 |
|
Not Applicable |
| 4.1(Raw Material) |
- |
400 |
|
- |
| 3(TYPES) |
- |
500 |
|
- |
| 4.2(Tapes – Linear Density
) |
- |
100 |
|
- |
| 4.3(Sacks) |
- |
100 |
|
- |
| 4.3.1( The two rows of stitches shall be separated from each other) |
- |
100 |
|
- |
| 4.3.1( The outer stitch) |
- |
100 |
|
- |
| 4.3.1(Stitches pass through a minimum of six layers of the fabric. ) |
- |
100 |
|
- |
| 4.2(Tapes – Width
IS 6192 and IS 11197) |
- |
200 |
|
- |
| 4.2(Construction) |
- |
100 |
|
- |
| 4.4 and Table 1 i(Capacity) |
- |
200 |
|
- |
|
31 Dec, 2026 |
- For finished product |
| 9641 |
IDMA LABORATORIES LIMITED, PANCHKULA
| 9123236
| IS 16920 (2018) |
Hexaconazole + zineb, wettable powder (WP) ? Specification |
- |
20500 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 3.1(Constituents) |
- |
0 |
|
Test Not Applicable |
| 3.2.1(Description) |
- |
1500 |
|
- |
| 3.2.2(Sieving Requirement) |
- |
2000 |
|
- |
| 3.2.3(Suspensibility) |
- |
6000 |
|
- |
| 3.2.4(Wettability) |
- |
2000 |
|
- |
| 3.3.1(Hexaconazole and Zineb Content) |
- |
7000 |
|
Testing Charges for Hexaconazole Content : INR 4000 + Zineb : INR 3000 |
| 3.3.2(Acidity or Alkalinity) |
- |
2000 |
|
- |
| 5(Packing) |
- |
0 |
|
Test not applicable |
| 6(Marking) |
- |
0 |
|
Test not applicable |
| 3.1(Constituents) |
- |
0 |
|
As above |
| 3.2.1(Description) |
- |
0 |
|
As Above |
| 3.2.2(Sieving Requirement) |
- |
0 |
|
As Above |
| 3.2.3(Suspensibility) |
- |
0 |
|
As Above |
| 3.2.4(Wettability) |
- |
0 |
|
As above |
| 3.3.1(Hexaconazole and Zineb Content) |
- |
0 |
|
As above |
| 3.3.2(Acidity or Alkalinity) |
- |
0 |
|
As Above |
| 5(Packing) |
- |
0 |
|
As Above |
| 6(Marking) |
- |
0 |
|
As Above |
|
31 Dec, 2029 |
- included w.e.f 17.10.2024 |
| 9642 |
IDMA LABORATORIES LIMITED, PANCHKULA
| 9123236
| IS 4431 (1978) |
Specification for carbon and carbon manganese free cutting steels (First Revision) |
- |
21000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl. 6(Vanadium) |
- |
1000 |
|
- |
| Cl. 6(Copper) |
- |
1000 |
|
- |
| Cl. 6(Nickel) |
- |
1000 |
|
- |
| Cl. 6(Molybdenum) |
- |
1000 |
|
- |
| Cl. 6(Chromium) |
- |
1000 |
|
- |
| Cl. 6(Phosphorus) |
- |
1000 |
|
- |
| Cl. 6(Sulphur) |
- |
1000 |
|
- |
| Cl. 6(Manganese) |
- |
1000 |
|
- |
| Cl. 6(Silicon) |
- |
1000 |
|
- |
| Cl. 6(Carbon) |
- |
1000 |
|
Testing charges for ( Chromium + Nickel + molybdenum + Copper + Vanadium ) are Rs. 900/- |
| 5(Freedom from defectes) |
- |
1000 |
|
- |
| 8.1(Tensile strength) |
- |
1200 |
|
Testing charges for Yield stress are Rs. 1200/- |
| 8.1(Elongation) |
- |
1200 |
|
Testing charges for Limiting ruling section are Rs. 2000/- |
| 8.1(Izod Impact) |
- |
2000 |
|
- |
| 9(Diameter) |
- |
1500 |
|
Total Testing Charges for Dimensions is INR 1500/- |
| 9(Out of Round) |
- |
0 |
|
As Above |
| 9(Straightness) |
- |
0 |
|
As Above |
| Cl. 6(Vanadium) |
- |
0 |
|
As Above |
| Cl. 6(Copper) |
- |
0 |
|
As Above |
| Cl. 6(Nickel) |
- |
0 |
|
As Above |
| Cl. 6(Molybdenum) |
- |
0 |
|
As Above |
| Cl. 6(Chromium) |
- |
0 |
|
As Above |
| Cl. 6(Phosphorus) |
- |
0 |
|
As Above |
| Cl. 6(Sulphur) |
- |
0 |
|
As Above |
| Cl. 6(Manganese) |
- |
0 |
|
As Above |
| Cl. 6(Silicon) |
- |
0 |
|
As Above |
| Cl. 6(Carbon) |
- |
0 |
|
As Above |
| 5(Freedom from defectes) |
- |
0 |
|
As Above |
| 8.1(Tensile strength) |
- |
0 |
|
As Above |
| 8.1(Elongation) |
- |
0 |
|
As Above |
| 8.1(Izod Impact) |
- |
0 |
|
As Above |
| 9(Diameter) |
- |
0 |
|
As Above |
| 9(Out of Round) |
- |
0 |
|
As Above |
| 9(Straightness) |
- |
0 |
|
As Above |
| Cl. 6(Vanadium) |
- |
0 |
|
As Above |
| Cl. 6(Copper) |
- |
0 |
|
As Above |
| Cl. 6(Nickel) |
- |
0 |
|
As Above |
| Cl. 6(Molybdenum) |
- |
0 |
|
As Above |
| Cl. 6(Chromium) |
- |
0 |
|
As Above |
| Cl. 6(Phosphorus) |
- |
0 |
|
As Above |
| Cl. 6(Sulphur) |
- |
0 |
|
As Above |
| Cl. 6(Manganese) |
- |
0 |
|
As Above |
| Cl. 6(Silicon) |
- |
0 |
|
As Above |
| Cl. 6(Carbon) |
- |
0 |
|
As Above |
| 5(Freedom from defectes) |
- |
0 |
|
As Above |
| 8.1(Tensile strength) |
- |
0 |
|
As Above |
| 8.1(Elongation) |
- |
0 |
|
As Above |
| 8.1(Izod Impact) |
- |
0 |
|
As Above |
| 9(Diameter) |
- |
0 |
|
As Above |
| 9(Out of Round) |
- |
0 |
|
As Above |
| 9(Straightness) |
- |
0 |
|
As Above |
|
31 Dec, 2029 |
- Included w.e.f 23.12.2024 |
| 9643 |
International Testing Centre, MSME Technology Development Centre, Meerut
| 8177804
| IS 3735 (1996) |
Canvas Shoes, Rubber Sole |
- |
15500 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl.4.5 Consolidation Test
IS 3400 (Part 5) : 1986 (From the quarter, cut a strip of 25.0 ± 0.5 mm width along the leagth of the boot
and of sufficient length to permit separation over a length of 75 mm. Carry out the test on two test pieces (one from each odd) at the rate of traverse of 100± 10mm per minute in accordance with IS 3400 (Part 5): 1986 or Static Dead Load
Method as given in Annex C. The individual adhesion value for consolidation test shall not be less than 30N (3.0 kgf) for each of the teat piecea (see Note
under 4.4).') |
- |
500 |
|
- |
| 4.1.1 Upper, Sl No. (i) of Table 1(The upper shall consist of over layer of cotton, manmade or blended
conforming' to the requirements given in Sl No. (i) of Table 1 as an overlayer and cotton drill conforming to the
requirements given in Sl No. (ii) of Table 1, as an inner layer or lining. The two fabrics shall be firmly adhered together with rubber compound. ) |
- |
500 |
|
- |
| Cl.4.1.1.1 Colour fastness(The dyed fabrics prescribed in 4.1.1 shall be fast todaylight and mechanical washing. Fastness to daylight
shall be of rating 4 or better, when tested in accordance with IS 686 : 1985 or IS 2454: 1985. However in case of dispute the method prescribed in IS 686 : 1985
shall be considered as referee method.) |
- |
500 |
|
- |
| Cl.4.1.2 Binding Material(IS 1954 : 1990)
(IS1969 : 1985)(Cotton tape NEWAR used as binding material shall conform to the requirements prescribed in col 3 of
Table 2, when tested in accordance with the methods referred to in col 4 of the table.) |
- |
500 |
|
- |
| Cl.4.1.2.1
Anmex B.(Cotton, manmade or blended shall be used as binding material.'
'Coloured cotton tapes shall have fastness to day light of rating as and if agreed
to between the purchaser and the supplier when tested in accordance with IS 686 :
1985. The black tapes shall be free from sulphur dyes when tested in accordance
with Annex B.') |
- |
300 |
|
- |
| Cl.4.1.3.1( Sewing thread cotton, manmade or blended shall be used for stitching of
upper. For cotton variety thread shall conform to variety No. 28 of IS 1720.
Polyester variety thread shall conform to variety No. 9 of IS 9543. Any other suitable thread shall have breaking load not less than above referred
requirement of specification.
Sewing thread cotton, manmade or blended shall be used for binding of upper. For cotton variety thread shall conform to variety No. 32 of IS 1720. Polyester variety thread shall conform to variety No. 5 of IS 9543.
Any other suitable thread shall have breaking load not less than above referred
requirement of specification.') |
- |
300 |
|
- |
| Cl.4.1.3.2 (IS 2454 : 1985)
IS 765 : 1979
IS 971 : 1966( The colour of the threads shall be as agreedto between the purchaser and the supplier. The dyed threads shall conform to the following requirements or IS 686 : 1985'.) |
- |
500 |
|
- |
| Cl.4.1.4(.Brass, steel or aluminium eyelets of 7.5 mm diameter and wall thickness 0.30 to
0.35 mm shall be used.') |
- |
300 |
|
- |
| Cl.4.1.5 Laces(
The shoes shall be provided with fabric braided laces
either matching the shade of the upper or black or The length of the lace shall be 60 ± 3 cm ) |
- |
300 |
|
- |
| Cl.4.1.5 Laces(and shallhave the breaking strength of not less than 250 N when tested between 18 cm grips in accordance with
IS 1969 : 1985, the rate of traverse of power actuated grip being 300 mm/min.) |
- |
500 |
|
- |
| Cl.4.1.5 Laces
Annex B(In case the laces are black,
the same shall pass the test for freedom from sulpher
dyes when tested in accordance with Annex B. The
two ends of the lace shall be provided with suitable
metal or plastic tips.) |
- |
300 |
|
- |
| Cl.4.1.6 Rubber Components(The rubber components shall conform to the requirements given in Table 4, when tested from finished boots.However in case it is not possible to cut the test pieces from the made up boots then 4.1.5.3 of IS
13695 : 1993 shall be followed.') |
- |
3000 |
|
- |
| Cl.4.1.6.2 Ageing
col 4 of Table 5.(The shoes shall be also aged at 70 ± 1°C for 168 h, on completion of which the test pieces taken from the shoes shall conform to the physical requirements
prescribed in col 4 of Table 5. ) |
- |
500 |
|
- |
| Cl.4.1.6.2 Ageing
(None of the rubber components of the shoes shall show any sign of tackiness or crack developed after ageing, when examined visually) |
- |
500 |
|
- |
| Cl.4.1.6.3 Thickness of components
in Table 6.(Individual components of the shoes shall comply with
the thickness and material requirements prescribed
in Table 6.) |
- |
500 |
|
- |
| CL.4.2 Shape and Design
IS 1638 : 1969(Cl 4.2.1 The shoes shall be made according to design
and pattern as agreed to between the purchaser and
the supplier. Size and fittings of the shoes shall be
in accordance with IS 1638 : 1969 unless otherwise
specified by the purchaser.) |
- |
300 |
|
- |
| Cl.4.2.2( The recommended design of canvas shoes is
shown in Fig. 1.) |
- |
300 |
|
- |
| Cl.4.3 Construction
Cl 4.3.1( The upper shall be stitched on a lock stitch machine and the number of stitches shall be 30 to
40 per dm.) |
- |
300 |
|
- |
| Cl.'4.3.2( Back of the upper shall be reinforced with a strip of upper material when
there is a seam.') |
- |
300 |
|
- |
| Cl.4.3.3( The counter shall be stitched at the back, set from bottom of lining and bound flat on top edge
with white/scoured binding material cut in bias and formed as a tape. T ) |
- |
300 |
|
- |
| Cl.4.3.4 (The vantp shall be strengthened with a rubber
toe-cap (see Fig. 1).) |
- |
300 |
|
- |
| Cl.4.3.5( Five pairs of eyelets shall be fitted in each
shoe. The eyelets shall be properly clenched without
any distortion. It shall properly match the colour of
the upper canvas, or as agreed to between the purchaser
and the supplier.) |
- |
300 |
|
- |
| Cl.4.3.6( The shoes shall be free from folds, wrinkles in the upper, blisters, embedded foreign matters and
excessive surface markings. In appearance, general workmanship, finish and all other respects, not defined
in the standard, the shoes shall be similar to the
sample approved by the purchaser, if any) |
- |
300 |
|
- |
| CL.4.3.7( The soles shall be of even substance and ofone layer only.) |
- |
300 |
|
- |
| Cl.4.3.8( A rubber foxing shall be fixed all round the sole and heel. The colour shall be as agreed to between the purchaser and the supplier. ) |
- |
300 |
|
- |
| Cl.4.4 Adhesion Test(From the upper-foxing portion where it is adhered to the canvas, parallel to the waist of sole, cut a strip of length 100 mm and width 8 mm. Separate out
the plies initially by breaking the bond to a length of about 75 mm. Carry out the test on two specimens in accordance with IS 3400 (Part 5) : 1986. There
shall be no further separation within 1 minute at a load of 1 kg for each of the two specimens.) |
- |
500 |
|
- |
| CL.4.6 Mass(The mass of one pair of finished shoes of size 8 shall not exceed 750 g with an increase or decrease of 25 g for each bigger or smaller size respectively) |
- |
300 |
|
- |
| Cl.4.5 Consolidation Test
IS 3400 (Part 5) : 1986 (From the quarter, cut a strip of 25.0 ± 0.5 mm width along the leagth of the boot
and of sufficient length to permit separation over a length of 75 mm. Carry out the test on two test pieces (one from each odd) at the rate of traverse of 100± 10mm per minute in accordance with IS 3400 (Part 5): 1986 or Static Dead Load
Method as given in Annex C. The individual adhesion value for consolidation test shall not be less than 30N (3.0 kgf) for each of the teat piecea (see Note
under 4.4).') |
- |
500 |
|
- |
| 4.1.1 Upper, Sl No. (i) of Table 1(The upper shall consist of over layer of cotton, manmade or blended
conforming' to the requirements given in Sl No. (i) of Table 1 as an overlayer and cotton drill conforming to the
requirements given in Sl No. (ii) of Table 1, as an inner layer or lining. The two fabrics shall be firmly adhered together with rubber compound. ) |
- |
300 |
|
- |
| Cl.4.1.1.1 Colour fastness(The dyed fabrics prescribed in 4.1.1 shall be fast todaylight and mechanical washing. Fastness to daylight
shall be of rating 4 or better, when tested in accordance with IS 686 : 1985 or IS 2454: 1985. However in case of dispute the method prescribed in IS 686 : 1985
shall be considered as referee method.) |
- |
500 |
|
- |
| Cl.4.1.2 Binding Material(IS 1954 : 1990)
(IS1969 : 1985)(Cotton tape NEWAR used as binding material shall conform to the requirements prescribed in col 3 of
Table 2, when tested in accordance with the methods referred to in col 4 of the table.) |
- |
500 |
|
- |
| Cl.4.1.2.1
Anmex B.(Cotton, manmade or blended shall be used as binding material.'
'Coloured cotton tapes shall have fastness to day light of rating as and if agreed
to between the purchaser and the supplier when tested in accordance with IS 686 :
1985. The black tapes shall be free from sulphur dyes when tested in accordance
with Annex B.') |
- |
300 |
|
- |
| Cl.4.1.3.1( Sewing thread cotton, manmade or blended shall be used for stitching of
upper. For cotton variety thread shall conform to variety No. 28 of IS 1720.
Polyester variety thread shall conform to variety No. 9 of IS 9543. Any other suitable thread shall have breaking load not less than above referred
requirement of specification.
Sewing thread cotton, manmade or blended shall be used for binding of upper. For cotton variety thread shall conform to variety No. 32 of IS 1720. Polyester variety thread shall conform to variety No. 5 of IS 9543.
Any other suitable thread shall have breaking load not less than above referred
requirement of specification.') |
- |
300 |
|
- |
| Cl.4.1.3.2 (IS 2454 : 1985)
IS 765 : 1979
IS 971 : 1966( The colour of the threads shall be as agreedto between the purchaser and the supplier. The dyed threads shall conform to the following requirements or IS 686 : 1985'.) |
- |
500 |
|
- |
| Cl.4.1.4(.Brass, steel or aluminium eyelets of 7.5 mm diameter and wall thickness 0.30 to
0.35 mm shall be used.') |
- |
300 |
|
- |
| Cl.4.1.5 Laces(
The shoes shall be provided with fabric braided laces
either matching the shade of the upper or black or The length of the lace shall be 60 ± 3 cm ) |
- |
300 |
|
- |
| Cl.4.1.5 Laces(and shallhave the breaking strength of not less than 250 N when tested between 18 cm grips in accordance with
IS 1969 : 1985, the rate of traverse of power actuated grip being 300 mm/min.) |
- |
500 |
|
- |
| Cl.4.1.5 Laces
Annex B(In case the laces are black,
the same shall pass the test for freedom from sulpher
dyes when tested in accordance with Annex B. The
two ends of the lace shall be provided with suitable
metal or plastic tips.) |
- |
300 |
|
- |
| Cl.4.1.6 Rubber Components(The rubber components shall conform to the requirements given in Table 4, when tested from finished boots.However in case it is not possible to cut the test pieces from the made up boots then 4.1.5.3 of IS
13695 : 1993 shall be followed.') |
- |
3000 |
|
- |
| Cl.4.1.6.2 Ageing
col 4 of Table 5.(The shoes shall be also aged at 70 ± 1°C for 168 h, on completion of which the test pieces taken from the shoes shall conform to the physical requirements
prescribed in col 4 of Table 5. ) |
- |
500 |
|
- |
| Cl.4.1.6.2 Ageing
(None of the rubber components of the shoes shall show any sign of tackiness or crack developed after ageing, when examined visually) |
- |
500 |
|
- |
| Cl.4.1.6.3 Thickness of components
in Table 6.(Individual components of the shoes shall comply with
the thickness and material requirements prescribed
in Table 6.) |
- |
500 |
|
- |
| CL.4.2 Shape and Design
IS 1638 : 1969(Cl 4.2.1 The shoes shall be made according to design
and pattern as agreed to between the purchaser and
the supplier. Size and fittings of the shoes shall be
in accordance with IS 1638 : 1969 unless otherwise
specified by the purchaser.) |
- |
300 |
|
- |
| Cl.4.2.2( The recommended design of canvas shoes is
shown in Fig. 1.) |
- |
300 |
|
- |
| Cl.4.3.3(he number of stitches shall be
30 to 40 per decimetre. The counter binding shall
meet the binding of the upper at the centre top edge
of the heel.) |
- |
300 |
|
- |
| Cl.4.3.3(The edges of quarter shall be bound with
dyed cotton binding material or matching to the colour
of the upper, cut in bias and formed as a tape.) |
- |
300 |
|
- |
| Cl.4.3.8(The foxing, not less
than 18 mm wide, shall not extend beyond the edges of the sole at the bottom) |
- |
300 |
|
- |
| Cl.4.3 Construction
Cl 4.3.1( The upper shall be stitched on a lock stitch machine and the number of stitches shall be 30 to
40 per dm.) |
- |
300 |
|
- |
| Cl.'4.3.2( Back of the upper shall be reinforced with a strip of upper material when
there is a seam.') |
- |
300 |
|
- |
| Cl.4.3.3( The counter shall be stitched at the back, set from bottom of lining and bound flat on top edge
with white/scoured binding material cut in bias and formed as a tape. T ) |
- |
300 |
|
- |
| Cl.4.3.3(he number of stitches shall be
30 to 40 per decimetre. The counter binding shall
meet the binding of the upper at the centre top edge
of the heel.) |
- |
300 |
|
- |
| Cl.4.3.3(The edges of quarter shall be bound with
dyed cotton binding material or matching to the colour
of the upper, cut in bias and formed as a tape.) |
- |
300 |
|
- |
| Cl.4.3.4 (The vantp shall be strengthened with a rubber
toe-cap (see Fig. 1).) |
- |
300 |
|
- |
| Cl.4.3.5( Five pairs of eyelets shall be fitted in each
shoe. The eyelets shall be properly clenched without
any distortion. It shall properly match the colour of
the upper canvas, or as agreed to between the purchaser
and the supplier.) |
- |
300 |
|
- |
| Cl.4.3.6( The shoes shall be free from folds, wrinkles in the upper, blisters, embedded foreign matters and
excessive surface markings. In appearance, general workmanship, finish and all other respects, not defined
in the standard, the shoes shall be similar to the
sample approved by the purchaser, if any) |
- |
300 |
|
- |
| CL.4.3.7( The soles shall be of even substance and ofone layer only.) |
- |
300 |
|
- |
| Cl.4.3.8( A rubber foxing shall be fixed all round the sole and heel. The colour shall be as agreed to between the purchaser and the supplier. ) |
- |
300 |
|
- |
| Cl.4.3.8(The foxing, not less
than 18 mm wide, shall not extend beyond the edges of the sole at the bottom) |
- |
300 |
|
- |
| Cl.4.4 Adhesion Test(From the upper-foxing portion where it is adhered to the canvas, parallel to the waist of sole, cut a strip of length 100 mm and width 8 mm. Separate out
the plies initially by breaking the bond to a length of about 75 mm. Carry out the test on two specimens in accordance with IS 3400 (Part 5) : 1986. There
shall be no further separation within 1 minute at a load of 1 kg for each of the two specimens.) |
- |
500 |
|
- |
| CL.4.6 Mass(The mass of one pair of finished shoes of size 8 shall not exceed 750 g with an increase or decrease of 25 g for each bigger or smaller size respectively) |
- |
300 |
|
- |
| Cl.4.5 Consolidation Test
IS 3400 (Part 5) : 1986 (From the quarter, cut a strip of 25.0 ± 0.5 mm width along the leagth of the boot
and of sufficient length to permit separation over a length of 75 mm. Carry out the test on two test pieces (one from each odd) at the rate of traverse of 100± 10mm per minute in accordance with IS 3400 (Part 5): 1986 or Static Dead Load
Method as given in Annex C. The individual adhesion value for consolidation test shall not be less than 30N (3.0 kgf) for each of the teat piecea (see Note
under 4.4).') |
- |
500 |
|
- |
| 4.1.1 Upper, Sl No. (i) of Table 1(The upper shall consist of over layer of cotton, manmade or blended
conforming' to the requirements given in Sl No. (i) of Table 1 as an overlayer and cotton drill conforming to the
requirements given in Sl No. (ii) of Table 1, as an inner layer or lining. The two fabrics shall be firmly adhered together with rubber compound. ) |
- |
300 |
|
- |
| Cl.4.1.1.1 Colour fastness(The dyed fabrics prescribed in 4.1.1 shall be fast todaylight and mechanical washing. Fastness to daylight
shall be of rating 4 or better, when tested in accordance with IS 686 : 1985 or IS 2454: 1985. However in case of dispute the method prescribed in IS 686 : 1985
shall be considered as referee method.) |
- |
500 |
|
- |
| Cl.4.1.2 Binding Material(IS 1954 : 1990)
(IS1969 : 1985)(Cotton tape NEWAR used as binding material shall conform to the requirements prescribed in col 3 of
Table 2, when tested in accordance with the methods referred to in col 4 of the table.) |
- |
500 |
|
- |
| Cl.4.1.2.1
Anmex B.(Cotton, manmade or blended shall be used as binding material.'
'Coloured cotton tapes shall have fastness to day light of rating as and if agreed
to between the purchaser and the supplier when tested in accordance with IS 686 :
1985. The black tapes shall be free from sulphur dyes when tested in accordance
with Annex B.') |
- |
300 |
|
- |
| Cl.4.1.3.1( Sewing thread cotton, manmade or blended shall be used for stitching of
upper. For cotton variety thread shall conform to variety No. 28 of IS 1720.
Polyester variety thread shall conform to variety No. 9 of IS 9543. Any other suitable thread shall have breaking load not less than above referred
requirement of specification.
Sewing thread cotton, manmade or blended shall be used for binding of upper. For cotton variety thread shall conform to variety No. 32 of IS 1720. Polyester variety thread shall conform to variety No. 5 of IS 9543.
Any other suitable thread shall have breaking load not less than above referred
requirement of specification.') |
- |
300 |
|
- |
| Cl.4.1.3.2 (IS 2454 : 1985)
IS 765 : 1979
IS 971 : 1966( The colour of the threads shall be as agreedto between the purchaser and the supplier. The dyed threads shall conform to the following requirements or IS 686 : 1985'.) |
- |
500 |
|
- |
| Cl.4.1.4(.Brass, steel or aluminium eyelets of 7.5 mm diameter and wall thickness 0.30 to
0.35 mm shall be used.') |
- |
300 |
|
- |
| Cl.4.1.5 Laces(
The shoes shall be provided with fabric braided laces
either matching the shade of the upper or black or The length of the lace shall be 60 ± 3 cm ) |
- |
300 |
|
- |
| Cl.4.1.5 Laces(and shallhave the breaking strength of not less than 250 N when tested between 18 cm grips in accordance with
IS 1969 : 1985, the rate of traverse of power actuated grip being 300 mm/min.) |
- |
500 |
|
- |
| Cl.4.1.5 Laces
Annex B(In case the laces are black,
the same shall pass the test for freedom from sulpher
dyes when tested in accordance with Annex B. The
two ends of the lace shall be provided with suitable
metal or plastic tips.) |
- |
300 |
|
- |
| Cl.4.1.6 Rubber Components(The rubber components shall conform to the requirements given in Table 4, when tested from finished boots.However in case it is not possible to cut the test pieces from the made up boots then 4.1.5.3 of IS
13695 : 1993 shall be followed.') |
- |
3000 |
|
- |
| Cl.4.1.6.2 Ageing
col 4 of Table 5.(The shoes shall be also aged at 70 ± 1°C for 168 h, on completion of which the test pieces taken from the shoes shall conform to the physical requirements
prescribed in col 4 of Table 5. ) |
- |
500 |
|
- |
| Cl.4.1.6.2 Ageing
(None of the rubber components of the shoes shall show any sign of tackiness or crack developed after ageing, when examined visually) |
- |
500 |
|
- |
| Cl.4.1.6.3 Thickness of components
in Table 6.(Individual components of the shoes shall comply with
the thickness and material requirements prescribed
in Table 6.) |
- |
300 |
|
- |
| CL.4.2 Shape and Design
IS 1638 : 1969(Cl 4.2.1 The shoes shall be made according to design
and pattern as agreed to between the purchaser and
the supplier. Size and fittings of the shoes shall be
in accordance with IS 1638 : 1969 unless otherwise
specified by the purchaser.) |
- |
300 |
|
- |
| Cl.4.2.2( The recommended design of canvas shoes is
shown in Fig. 1.) |
- |
300 |
|
- |
| Cl.4.3 Construction
Cl 4.3.1( The upper shall be stitched on a lock stitch machine and the number of stitches shall be 30 to
40 per dm.) |
- |
300 |
|
- |
| Cl.'4.3.2( Back of the upper shall be reinforced with a strip of upper material when
there is a seam.') |
- |
300 |
|
- |
| Cl.4.3.3( The counter shall be stitched at the back, set from bottom of lining and bound flat on top edge
with white/scoured binding material cut in bias and formed as a tape. T ) |
- |
300 |
|
- |
| Cl.4.3.3(he number of stitches shall be
30 to 40 per decimetre. The counter binding shall
meet the binding of the upper at the centre top edge
of the heel.) |
- |
300 |
|
- |
| Cl.4.3.3(The edges of quarter shall be bound with
dyed cotton binding material or matching to the colour
of the upper, cut in bias and formed as a tape.) |
- |
300 |
|
- |
| Cl.4.3.4 (The vantp shall be strengthened with a rubber
toe-cap (see Fig. 1).) |
- |
300 |
|
- |
| Cl.4.3.5( Five pairs of eyelets shall be fitted in each
shoe. The eyelets shall be properly clenched without
any distortion. It shall properly match the colour of
the upper canvas, or as agreed to between the purchaser
and the supplier.) |
- |
300 |
|
- |
| Cl.4.3.6( The shoes shall be free from folds, wrinkles in the upper, blisters, embedded foreign matters and
excessive surface markings. In appearance, general workmanship, finish and all other respects, not defined
in the standard, the shoes shall be similar to the
sample approved by the purchaser, if any) |
- |
300 |
|
- |
| CL.4.3.7( The soles shall be of even substance and ofone layer only.) |
- |
300 |
|
- |
| Cl.4.3.8( A rubber foxing shall be fixed all round the sole and heel. The colour shall be as agreed to between the purchaser and the supplier. ) |
- |
300 |
|
- |
| Cl.4.3.8(The foxing, not less
than 18 mm wide, shall not extend beyond the edges of the sole at the bottom) |
- |
300 |
|
- |
| Cl.4.4 Adhesion Test(From the upper-foxing portion where it is adhered to the canvas, parallel to the waist of sole, cut a strip of length 100 mm and width 8 mm. Separate out
the plies initially by breaking the bond to a length of about 75 mm. Carry out the test on two specimens in accordance with IS 3400 (Part 5) : 1986. There
shall be no further separation within 1 minute at a load of 1 kg for each of the two specimens.) |
- |
500 |
|
- |
| CL.4.6 Mass(The mass of one pair of finished shoes of size 8 shall not exceed 750 g with an increase or decrease of 25 g for each bigger or smaller size respectively) |
- |
300 |
|
- |
| 4.8(Adhesion ) |
- |
500 |
|
- |
| 4.7(Consolidation test ) |
- |
500 |
|
- |
| 4.6(Mass ) |
- |
300 |
|
- |
| 4.5(Finish ) |
- |
300 |
|
- |
| 4.4(Contruction ) |
- |
300 |
|
- |
| 4.3(Leg Height ) |
- |
300 |
|
- |
| 4.2(Design ) |
- |
300 |
|
- |
| 4.1.6.2(Thickness of components ) |
- |
500 |
|
- |
| 4.1.6.2(Ageing) |
- |
500 |
|
- |
| 4.1.6.2(Elongation at break after ageing ) |
- |
500 |
|
- |
| 4.1.6.2(Tensile after ageing ) |
- |
500 |
|
- |
| 4.1.6(Compression set ) |
- |
800 |
|
- |
| 4.1.6(Elongation at break ) |
- |
500 |
|
- |
| 4.1.6(Tensile strength) |
- |
500 |
|
- |
| 4.1.6(Hardness (after accelerated )) |
- |
300 |
|
- |
| 4.1.6(Flexing resistance test) |
- |
800 |
|
- |
| 4.1.6(Hardness ) |
- |
300 |
|
- |
| 4.1.6(Relative density) |
- |
300 |
|
- |
| 4.1.5(Sulpher dyes content ) |
- |
500 |
|
- |
| 4.1.5(Breaking Load ) |
- |
500 |
|
- |
| 4.1.5(Length ) |
- |
300 |
|
- |
| 4.1.4(Thickness) |
- |
300 |
|
- |
| 4.1.4(Size ) |
- |
300 |
|
- |
| 4.1.3(Color fastness to perspiration) |
- |
500 |
|
- |
| 4.1.3(Colorfastness to washing) |
- |
500 |
|
- |
| 4.1.3(Colorfastness to light ) |
- |
500 |
|
- |
| 4.1.3(Single thread breaking load) |
- |
500 |
|
- |
| 4.1.3(Construction ) |
- |
300 |
|
- |
| 4.1.2(Colorfastness to light ) |
- |
500 |
|
- |
| 4.1.2(Colorfastness to washing) |
- |
500 |
|
- |
| 4.1.2(Breaking Strength ) |
- |
500 |
|
- |
| 4.1.2(Width ) |
- |
300 |
|
- |
| 4.1.1.2(Colorfastness to washing) |
- |
500 |
|
- |
| 4.1.1.1(Colorfastness to light ) |
- |
500 |
|
- |
| 4.1.1 (Drill) (End & Picks/dm) |
- |
300 |
|
- |
| 4.1.1 (Drill) (Colorfastness to light ) |
- |
500 |
|
- |
| 4.1.1 (canvas )(End & Picks/dm) |
- |
300 |
|
- |
| 4.1.1 (canvas )(Breaking Load ) |
- |
500 |
|
- |
| 5, 5.1, Cl. 5.2, Cl. 5.2.1, Cl. 5.2.1.1(Packing and marking) |
- |
300 |
|
- |
| " CL. 5.1, Cl. 5.2, Cl. 5.2.1, Cl. 5.2.1.1(Packing and marking ") |
- |
300 |
|
- |
|
15 Apr, 2027 |
- Included w.e.f 19.09.2024 |
| 9644 |
IDMA LABORATORIES LIMITED, PANCHKULA
| 9123236
| IS 11686 (1997) |
Isopropyl alcohol, food grade - Specification (First Revision) |
- |
24000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 3(Description) |
- |
1500 |
|
- |
| 4 - Table 1 -(i)(Purity of Isopropyl alcohol percent by mass) |
- |
3500 |
|
- |
| 4 - Table 1 -(ii)(Relative density) |
- |
2500 |
|
- |
| 4 - Table 1 -(iii)(Colour) |
- |
2000 |
|
- |
| 4 - Table 1 -(iv)(Distillation range) |
- |
3500 |
|
- |
| 4 - Table 1 -(v)(Acidity percent by mass) |
- |
1500 |
|
- |
| 4 - Table 1 -(vi)(Non-volatile matter) |
- |
1500 |
|
- |
| 4 - Table 1 -(vii)(Aldehydes and ketones percent by mass) |
- |
2500 |
|
- |
| 4 - Table 1 -(viii)(Substance reducing permanganate) |
- |
1500 |
|
- |
| 4 - Table 1 -(ix)(Heavy metals) |
- |
2000 |
|
- |
| 4 - Table 1 -(x)(Moisture percent by mass) |
- |
2000 |
|
- |
| 5.1(PACKING) |
- |
0 |
|
Test not applicable |
| 5.2(STORAGE) |
- |
0 |
|
Test not applicable |
| 5.3(MARKING) |
- |
0 |
|
Test not applicable |
| 3(Description) |
- |
- |
|
- |
| 4 - Table 1 -(i)(Purity of Isopropyl alcohol percent by mass) |
- |
- |
|
- |
| 4 - Table 1 -(ii)(Relative density) |
- |
- |
|
- |
| 4 - Table 1 -(iii)(Colour) |
- |
- |
|
- |
| 4 - Table 1 -(iv)(Distillation range) |
- |
- |
|
- |
| 4 - Table 1 -(v)(Acidity percent by mass) |
- |
- |
|
- |
| 4 - Table 1 -(vi)(Non-volatile matter) |
- |
- |
|
- |
| 4 - Table 1 -(vii)(Aldehydes and ketones percent by mass) |
- |
- |
|
- |
| 4 - Table 1 -(viii)(Substance reducing permanganate) |
- |
- |
|
- |
| 4 - Table 1 -(ix)(Heavy metals) |
- |
- |
|
- |
| 4 - Table 1 -(x)(Moisture percent by mass) |
- |
- |
|
- |
| 5.1(PACKING) |
- |
- |
|
- |
| 5.2(STORAGE) |
- |
- |
|
- |
| 5.3(MARKING) |
- |
- |
|
- |
|
31 Dec, 2029 |
- Included w.e.f.07.11.2024 |
| 9645 |
IDMA LABORATORIES LIMITED, PANCHKULA
| 9123236
| IS 10301 (1982) |
Specification for isopropyl alcohol for cosmetic industry |
- |
19000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 2.1(Description) |
- |
1000 |
|
- |
| 2.2(Odour) |
- |
1000 |
|
- |
| 2.1 - Table 1 - (i)(Relative density) |
- |
2500 |
|
- |
| 2.1 - Table 1 - (ii)(Distillation range) |
- |
3500 |
|
- |
| 2.1 - Table 1 - (iii)(Residue, Max) |
- |
2500 |
|
- |
| 2.1 - Table 1 - (iv)(Acidity, Max) |
- |
2000 |
|
- |
| 2.1 - Table 1 - (v)(Aldehydes and Ketons, Max) |
- |
3500 |
|
- |
| 2.1 - Table 1 - (vi)(Water content, Max) |
- |
3000 |
|
- |
| 3(Packing and Marking) |
- |
0 |
|
Test Not Applicable |
|
31 Dec, 2029 |
- Included w.e.f.07.11.2024 |
| 9646 |
BIS, Central Laboratory (CL)
| None
| IS 4766 (2024) |
Thiram water dispersible powder for slurry seed treatment - Specification (second revision) |
- |
- View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| CL 3.1 (Description) |
- |
|
|
|
| CL 3.3, Table 1, S.No (i) (Thiram Content) |
- |
|
|
|
| CL 3.3, Table 1, S.No (ii) (Sieving) |
- |
|
|
|
| CL 3.3, Table 1, S.No (iii) (Wettability) |
- |
|
|
|
|
- |
- - |
| 9647 |
Bharat Test House Pvt Ltd 781 Sonipat Haryana
| 9137826
| IS 302 : Part 2 : Sec 207 (1994) |
Safety of household and similar electrical appliances: Part 2 particular requirements: Sec 207 electric hot plates |
Electric hot plates |
22500 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4(General) |
- |
0 |
|
- |
| 5(Rating) |
- |
100 |
|
- |
| 6(Classification) |
- |
100 |
|
- |
| 7(Marking) |
- |
100 |
|
- |
| 11(TEMPERATURE RISE) |
- |
1500 |
|
- |
| 12("OPERATION UNDER OVERLOAD
CONDITIONS OF APPLIANCES WITH
HEATING ELEMENTS") |
- |
1000 |
|
- |
| 13(" ELECTRICAL INSULATION AND LEKAGE
CURRENT AT OPERATING TEMPERATURE ") |
- |
800 |
|
- |
| 15(MOISTURE RESISTANCE) |
- |
3000 |
|
- |
| 16("INSULATION RESlSTANCE AND
specified in 16.2.
ELECTRIC SHOCK STRENGTH ( AFTER
HUMIDITY TREATMENT )") |
- |
800 |
|
- |
| 19(ABNORMAL OPERATION) |
- |
2000 |
|
- |
| 20("STABILITY AND MECHANICAL
HAZARDS") |
- |
500 |
|
- |
| 21(MECHANICAL STRENGTH) |
- |
800 |
|
- |
| 22(CONSTRUCTION) |
- |
2000 |
|
- |
| 23(INTERNAL WIRING) |
- |
500 |
|
- |
| 24(COMPONENTS) |
- |
500 |
|
- |
| 25("SUPPLY CONNECTION AND EXTERNAL
FLEXIBLE CABLES AND CORDS ") |
- |
750 |
|
- |
| 26("TERMINALS FOR EXTERNAL
CONDUCTORS") |
- |
500 |
|
- |
| 27(PROVISION FOR EARTHING) |
- |
500 |
|
- |
| 28(SCREWS AND CONNECTIONS) |
- |
600 |
|
- |
| 30("RESISTANCE TO HEAT, FIRE AND
TRACKING ") |
- |
2000 |
|
- |
| 31(RESISTANCE TO RUSTING) |
- |
750 |
|
- |
| 8("PROTECTION AGAINST ELECTRIC
SHOCK ") |
- |
500 |
|
- |
|
31 Dec, 2029 |
- Included.w.e.f.13.11.2024. Exclusion : 19.11.4.1 to 19.11.4.7 (EMI/EMC) |
| 9648 |
Hi Physix Laboratory India Private Limited, Pune
| 7126926
| IS 2993 : Part 1 (2024) |
a.c. Motor Capacitors Part 1 General - Performance, Testing and Rating - Safety Requirements - Guidance for Installation and Operation ( Third Revision ) |
- |
455750 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 5.1.1(General) |
- |
4000 |
|
- |
| 5.5(Tangent of loss angle) |
- |
18000 |
|
- |
| 5.7("Voltage test between terminals
") |
- |
9000 |
|
- |
| 5.8(Voltage test between terminals and case) |
- |
9000 |
|
- |
| 5.9(Capacitance measurement) |
- |
13500 |
|
- |
| 5.9(Capacitance measurement) |
- |
0 |
|
- |
| 5.1(Check of dimensions) |
- |
4000 |
|
Actual Cl. no. is 5.10 |
| 5.11(Mechanical tests) |
- |
62500 |
|
- |
| 5.12(Sealing test) |
- |
9000 |
|
- |
| 5.13(Endurance test) |
- |
192500 |
|
- |
| 5.14(Damp heat test) |
- |
66000 |
|
- |
| 5.15(Self-healing test) |
- |
9000 |
|
- |
| 5.16(Destruction test) |
- |
44250 |
|
- |
| 5.17(Resistance to heat, fire and tracking) |
- |
0 |
|
- |
| 5.17.1(Ball-pressure test) |
- |
3000 |
|
- |
| 5.17.2(Glow-wire test) |
- |
3000 |
|
- |
| 5.17.3(Tracking test) |
- |
5000 |
|
- |
| 6.1(Maximum permissible voltage) |
- |
0 |
|
- |
| 6.2("Maximum permissible current
") |
- |
0 |
|
- |
| 6.3(Maximum permissible reactive output) |
- |
0 |
|
- |
| 7(Safety requirements) |
- |
0 |
|
- |
| 7.1(Requirements for Creepage distances and clearances) |
- |
0 |
|
- |
| 7.2(Terminals and connecting cables) |
- |
0 |
|
- |
| 7.3(Earth connections) |
- |
0 |
|
- |
| 7.4(Discharge devices) |
- |
0 |
|
- |
| 8(Marking) |
- |
4000 |
|
- |
| 9.2.1(Measurements of working voltage) |
- |
0 |
|
- |
| 9.2.2(Influence of capacitance) |
- |
0 |
|
- |
| 9.3(Checking capacitor temperature) |
- |
0 |
|
- |
| 9.4(Checking transients) |
- |
0 |
|
- |
| 9.5(Leakage current) |
- |
0 |
|
- |
| 5.1.1(General) |
- |
0 |
|
- |
| 5.5(Tangent of loss angle) |
- |
0 |
|
- |
| 5.7("Voltage test between terminals
") |
- |
0 |
|
- |
| 5.8(Voltage test between terminals and case) |
- |
0 |
|
- |
| 5.9(Capacitance measurement) |
- |
0 |
|
- |
| 5.9(Capacitance measurement) |
- |
0 |
|
- |
| 5.1(Check of dimensions) |
- |
0 |
|
- |
| 5.11(Mechanical tests) |
- |
0 |
|
- |
| 5.12(Sealing test) |
- |
0 |
|
- |
| 5.13(Endurance test) |
- |
0 |
|
- |
| 5.14(Damp heat test) |
- |
0 |
|
- |
| 5.15(Self-healing test) |
- |
0 |
|
- |
| 5.16(Destruction test) |
- |
0 |
|
- |
| 5.17(Resistance to heat, fire and tracking) |
- |
0 |
|
- |
| 5.17.1(Ball-pressure test) |
- |
0 |
|
- |
| 5.17.2(Glow-wire test) |
- |
0 |
|
- |
| 5.17.3(Tracking test) |
- |
0 |
|
- |
| 6.1(Maximum permissible voltage) |
- |
0 |
|
- |
| 6.2("Maximum permissible current
") |
- |
0 |
|
- |
| 6.3(Maximum permissible reactive output) |
- |
0 |
|
- |
| 7(Safety requirements) |
- |
0 |
|
- |
| 7.1(Requirements for Creepage distances and clearances) |
- |
0 |
|
- |
| 7.2(Terminals and connecting cables) |
- |
0 |
|
- |
| 7.3(Earth connections) |
- |
0 |
|
- |
| 7.4(Discharge devices) |
- |
0 |
|
- |
| 8(Marking) |
- |
0 |
|
- |
| 9.2.1(Measurements of working voltage) |
- |
0 |
|
- |
| 9.2.2(Influence of capacitance) |
- |
0 |
|
- |
| 9.3(Checking capacitor temperature) |
- |
0 |
|
- |
| 9.4(Checking transients) |
- |
0 |
|
- |
| 9.5(Leakage current) |
- |
0 |
|
- |
| 5.1.1(General) |
- |
0 |
|
- |
| 5.5(Tangent of loss angle) |
- |
0 |
|
- |
| 5.7("Voltage test between terminals
") |
- |
0 |
|
- |
| 5.8(Voltage test between terminals and case) |
- |
0 |
|
- |
| 5.9(Capacitance measurement) |
- |
0 |
|
- |
| 5.9(Capacitance measurement) |
- |
0 |
|
- |
| 5.1(Check of dimensions) |
- |
0 |
|
- |
| 5.11(Mechanical tests) |
- |
0 |
|
- |
| 5.12(Sealing test) |
- |
0 |
|
- |
| 5.13(Endurance test) |
- |
0 |
|
- |
| 5.14(Damp heat test) |
- |
0 |
|
- |
| 5.15(Self-healing test) |
- |
0 |
|
- |
| 5.16(Destruction test) |
- |
0 |
|
- |
| 5.17(Resistance to heat, fire and tracking) |
- |
0 |
|
- |
| 5.17.1(Ball-pressure test) |
- |
0 |
|
- |
| 5.17.2(Glow-wire test) |
- |
0 |
|
- |
| 5.17.3(Tracking test) |
- |
0 |
|
- |
| 6.1(Maximum permissible voltage) |
- |
0 |
|
- |
| 6.2("Maximum permissible current
") |
- |
0 |
|
- |
| 6.3(Maximum permissible reactive output) |
- |
0 |
|
- |
| 7(Safety requirements) |
- |
0 |
|
- |
| 7.1(Requirements for Creepage distances and clearances) |
- |
0 |
|
- |
| 7.2(Terminals and connecting cables) |
- |
0 |
|
- |
| 7.3(Earth connections) |
- |
0 |
|
- |
| 7.4(Discharge devices) |
- |
0 |
|
- |
| 8(Marking) |
- |
0 |
|
- |
| 9.2.1(Measurements of working voltage) |
- |
0 |
|
- |
| 9.2.2(Influence of capacitance) |
- |
0 |
|
- |
| 9.3(Checking capacitor temperature) |
- |
0 |
|
- |
| 9.4(Checking transients) |
- |
0 |
|
- |
| 9.5(Leakage current) |
- |
0 |
|
- |
|
20 Jun, 2028 |
- Included w.e.f.08.11.2024 |
| 9649 |
IDMA LABORATORIES LIMITED, PANCHKULA
| 9123236
| IS 2630 (2021) |
NITROBENZENE SPECIFICATION |
- |
29000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Clause 3.1(Description) |
- |
1000 |
|
- |
| Clause 3.2
Table 1(i)(Relative density
at 27 °C/27 °C) |
- |
2500 |
|
- |
| Clause 3.2
Table 1(ii)(Distillation range
at 760 mm Hg.) |
- |
4000 |
|
- |
| Clause 3.2
Table 1(iii)(Crystallization
point °C, Min) |
- |
3000 |
|
- |
| Clause 3.2
Table 1(iv)(Moisture, percent
by Mass, Max) |
- |
2500 |
|
- |
| Clause 3.2
Table 1(v)(pH, Min) |
- |
1500 |
|
- |
| Clause 3.2
Table 1(vi)(Dinitrobenzene, percent
by Mass, Max) |
- |
3000 |
|
- |
| Clause 3.2
Table 1(vii)(Assay, percent by Mass, Max) |
- |
4000 |
|
- |
| Clause 3.2
Table 1(viii)(Low boilers (Benzene)
percent by Mass, Max) |
- |
3500 |
|
- |
| Clause 3.2
Table 1(ix)(High boilers (o-nitrotoluene,
p-nitrotoluene, p-nitrochlorobenzene, and
m-dinitrobenzene), percent by mass, Max) |
- |
4000 |
|
- |
| Clause 4.1(Packing) |
- |
0 |
|
Test not applicable |
| Clause 4.2(Marking) |
- |
0 |
|
Test not Applicable |
| Clause 3.1(Description) |
- |
1000 |
|
- |
| Clause 3.2
Table 1(i)(Relative density
at 27 °C/27 °C) |
- |
2500 |
|
- |
| Clause 3.2
Table 1(ii)(Distillation range
at 760 mm Hg.) |
- |
4000 |
|
- |
| Clause 3.2
Table 1(iii)(Crystallization
point °C, Min) |
- |
3000 |
|
- |
| Clause 3.2
Table 1(iv)(Moisture, percent
by Mass, Max) |
- |
2500 |
|
- |
| Clause 3.2
Table 1(v)(pH, Min) |
- |
1500 |
|
- |
| Clause 3.2
Table 1(vi)(Dinitrobenzene, percent
by Mass, Max) |
- |
3000 |
|
- |
| Clause 3.2
Table 1(vii)(Assay, percent by Mass, Max) |
- |
4000 |
|
- |
| Clause 3.2
Table 1(viii)(Low boilers (Benzene)
percent by Mass, Max) |
- |
3500 |
|
- |
| Clause 3.2
Table 1(ix)(High boilers (o-nitrotoluene,
p-nitrotoluene, p-nitrochlorobenzene, and
m-dinitrobenzene), percent by mass, Max) |
- |
4000 |
|
- |
| Clause 4.1(Packing) |
- |
0 |
|
Test not applicable |
| Clause 4.2(Marking) |
- |
0 |
|
Test not applicable |
|
31 Dec, 2029 |
- Included w.e.f 09.10.2024 |
| 9650 |
Central Institute of Petrochemicals Engineering & Technology (CIPET), Chandrapur
| 7173804
| IS 7180 (1973) |
Specification for disposable artificial insemination gloves |
Disposable Artificial Insemination Gloves |
7450.0 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 2.1(Glove Material) |
- |
1050.0 |
|
GST EXTRA |
| 3.1(Thickness) |
- |
1000.0 |
|
Charges Including Clause 3 & 3.2
GST EXTRA |
| 4.1(Appearance) |
- |
500.0 |
|
GST EXTRA |
| 5.1(Tensile Strength of the film) |
- |
2600.0 |
|
Charges 1300.0 + 1300.0 = 2600.0 (Lengthwise & Widthwise)
GST EXTRA |
| 7.1(Density) |
- |
700.0 |
|
GST EXTRA |
| 10.2(Marking) |
- |
1600.0 |
|
Charges Including for Clause 8 =500.0, Clause 9 =600.0 & Clause 12.1 =500.0
GST EXTRA |
| 2.1(Glove Material) |
- |
0.00 |
|
- |
| 3.1(Thickness) |
- |
0.00 |
|
- |
| 4.1(Appearance) |
- |
0.00 |
|
- |
| 5.1(Tensile Strength of the film) |
- |
0.00 |
|
- |
| 7.1(Density) |
- |
0.00 |
|
- |
| 10.2(Marking) |
- |
0.00 |
|
- |
| 2.1(Glove Material) |
- |
0.00 |
|
- |
| 3.1(Thickness) |
- |
0.00 |
|
- |
| 4.1(Appearance) |
- |
0.00 |
|
- |
| 5.1(Tensile Strength of the film) |
- |
0.00 |
|
- |
| 7.1(Density) |
- |
0.00 |
|
- |
| 10.2(Marking) |
- |
0.00 |
|
- |
| 2.1(Glove Material) |
- |
0.00 |
|
- |
| 3.1(Thickness) |
- |
0.00 |
|
- |
| 4.1(Appearance) |
- |
0.00 |
|
- |
| 5.1(Tensile Strength of the film) |
- |
0.00 |
|
- |
| 7.1(Density) |
- |
0.00 |
|
- |
| 10.2(Marking) |
- |
0.00 |
|
- |
|
10 Sep, 2029 |
- Included w.e.f 19.09.2024 |
| 9651 |
WELL TECH TEST AND RESEARCH CENTER, DERABASSI
| 9177306
| IS 7092 : Part 2 (1987) |
Specification for aluminium alloy tube for irrigation purposes: Part 2 extruded tube (Second Revision) |
TABLE 2 |
17500 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl.4(Workmanship & Finish) |
- |
1000 |
|
- |
| Cl.6.2(Ultimate Tensile Strength- IS 2657) |
- |
2000 |
|
- |
| Cl.6.2(0.2 percent proof strength- IS 2657) |
- |
2000 |
|
- |
| Cl.6.2(Elongation on 50 mm gauge length- IS 2657) |
- |
1500 |
|
- |
| Cl. 6.3(Drift Expanding Test ( Expanded Inside Diameter- IS 2335) |
- |
2500 |
|
- |
| Cl. 6.4(Hydrostatic Pressure Test-Cl. 6.4) |
- |
2500 |
|
- |
| Cl.7.1, Table 2(Outside Diameter-) |
- |
1000 |
|
- |
| Cl.7.1, Table 2(Roundness or Ovality) |
- |
1000 |
|
- |
| Cl.7.1, Table 2(Wall Thickness) |
- |
1000 |
|
- |
| Cl. 7.2(Length) |
- |
500 |
|
- |
| Cl. 6.1(Copper- IS 504 or any other established instrumental/ chemical method) |
- |
500 |
|
- |
| Cl. 6.1(Magnesium- IS 504 or any other established instrumental/ chemical method) |
- |
500 |
|
- |
| Cl. 6.1(Silicon- IS 504 or any other established instrumental/ chemical method) |
- |
500 |
|
- |
| Cl. 6.1(Iron- IS 504 or any other established instrumental/ chemical method) |
- |
500 |
|
- |
| Cl. 6.1(Manganese- IS 504 or any other established instrumental/ chemical method) |
- |
500 |
|
- |
| Cl. 6.1(Zinc- IS 504 or any other established instrumental/ chemical method) |
- |
500 |
|
- |
| Cl. 6.1(Chromium- IS 504 or any other established instrumental/ chemical method) |
- |
500 |
|
- |
| Cl. 6.1(Titanium and/ other grain refining elements) |
- |
1000 |
|
- |
| Cl. 6.1(Aluminium- IS 504 or any other established instrumental/ chemical method) |
- |
1000 |
|
- |
| 9.1(Marking) |
- |
500 |
|
- |
| 14(Workmanship & Finish) |
- |
0 |
|
- |
| 7.1(Dimensions) |
- |
0 |
|
- |
| 6.2(Mechanical properties) |
- |
0 |
|
- |
| 6.3(Drift Expanding Test) |
- |
0 |
|
- |
| 6.4(Drift Expanding Testt) |
- |
0 |
|
- |
| 5.3.2(hydrostatic pressure test) |
- |
0 |
|
- |
| 6.3(Drift expanding test) |
- |
0 |
|
- |
| 7.1 table 2(Dimensions and tolerances for extruded tubes) |
- |
0 |
|
- |
| 6.1(chemical composition) |
- |
0 |
|
- |
| 6.2(ultimate tensile strength) |
- |
0 |
|
- |
| 6.2(0.2% proof strength) |
- |
0 |
|
- |
| 6.2(Elongation on 50 mm gauge length) |
- |
0 |
|
- |
| Cl.4(Workmanship & Finish) |
- |
0 |
|
- |
| Cl.6.2(Ultimate Tensile Strength- IS 2657) |
- |
0 |
|
- |
| Cl.6.2(0.2 percent proof strength- IS 2657) |
- |
0 |
|
- |
| Cl.6.2(Elongation on 50 mm gauge length- IS 2657) |
- |
0 |
|
- |
| Cl. 6.3(Drift Expanding Test ( Expanded Inside Diameter- IS 2335) |
- |
0 |
|
- |
| Cl. 6.4(Hydrostatic Pressure Test-Cl. 6.4) |
- |
0 |
|
- |
| Cl.7.1, Table 2(Outside Diameter-) |
- |
0 |
|
- |
| Cl.7.1, Table 2(Roundness or Ovality) |
- |
0 |
|
- |
| Cl.7.1, Table 2(Wall Thickness) |
- |
0 |
|
- |
| Cl. 7.2(Length) |
- |
0 |
|
- |
| Cl. 6.1(Copper- IS 504 or any other established instrumental/ chemical method) |
- |
0 |
|
- |
| Cl. 6.1(Magnesium- IS 504 or any other established instrumental/ chemical method) |
- |
0 |
|
- |
| Cl. 6.1(Silicon- IS 504 or any other established instrumental/ chemical method) |
- |
0 |
|
- |
| Cl. 6.1(Iron- IS 504 or any other established instrumental/ chemical method) |
- |
0 |
|
- |
| Cl. 6.1(Manganese- IS 504 or any other established instrumental/ chemical method) |
- |
0 |
|
- |
| Cl. 6.1(Zinc- IS 504 or any other established instrumental/ chemical method) |
- |
0 |
|
- |
| Cl. 6.1(Chromium- IS 504 or any other established instrumental/ chemical method) |
- |
0 |
|
- |
| Cl. 6.1(Titanium and/ other grain refining elements) |
- |
0 |
|
- |
| Cl. 6.1(Aluminium- IS 504 or any other established instrumental/ chemical method) |
- |
0 |
|
- |
| 9.1(Marking) |
- |
0 |
|
- |
| 14(Workmanship & Finish) |
- |
0 |
|
- |
| 7.1(Dimensions) |
- |
0 |
|
- |
| 6.2(Mechanical properties) |
- |
0 |
|
- |
| 6.3(Drift Expanding Test) |
- |
0 |
|
- |
| 6.4(Drift Expanding Testt) |
- |
0 |
|
- |
| 5.3.2(hydrostatic pressure test) |
- |
0 |
|
- |
| 6.3(Drift expanding test) |
- |
0 |
|
- |
| 7.1 table 2(Dimensions and tolerances for extruded tubes) |
- |
0 |
|
- |
| 6.1(chemical composition) |
- |
0 |
|
- |
| 6.2(ultimate tensile strength) |
- |
0 |
|
- |
| 6.2(0.2% proof strength) |
- |
0 |
|
- |
| 6.2(Elongation on 50 mm gauge length) |
- |
0 |
|
- |
|
30 Mar, 2027 |
- Included w.e.f 07.01.2025 |
| 9652 |
Aaditech Test and Calibration Lab LLP
| 8179926
| IS 3854 (2023) |
Switches for Domestic and Similar Purposes - Specification (Third Revision) |
- |
10000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl-4(General Requirements) |
- |
500 |
|
- |
| Cl-5(General notes on tests) |
- |
500 |
|
- |
| Cl-6(Rating) |
- |
500 |
|
- |
| Cl-8(Marking) |
- |
700 |
|
- |
| Cl-9(Checking of dimensions) |
- |
700 |
|
- |
| Cl-10.1, 10.2(Prevention of Access to Live Parts) |
- |
500 |
|
- |
| Cl-10.3(Requirements for Accessible Metal Parts) |
- |
500 |
|
- |
| Cl-10.4(Requirements for Insulation of the Mechanism) |
- |
500 |
|
- |
| Cl. 10.5(Requirements for Insulation of the Mechanism with Respect to the Surrounding Environment) |
- |
500 |
|
- |
| Cl-10.6(Requirements for Switches Operated Indirectly) |
- |
500 |
|
- |
| Cl-10.7(Requirements for Switches with Replaceable Pull Cord) |
- |
500 |
|
- |
| Cl-11(Provision for earthing) |
- |
1000 |
|
- |
| Cl-12(Terminals) |
- |
1000 |
|
- |
| Cl-13(Constructional requirements) |
- |
1500 |
|
- |
| Cl-14(Mechanism) |
- |
1000 |
|
- |
| Cl-15.1(Resistance to Ageing) |
- |
2000 |
|
- |
| Cl-15.2(Protection Provided by Enclosures of Switches) |
- |
1000 |
|
- |
| Cl-15.3(Resistance to Humidity) |
- |
1500 |
|
- |
| Cl-16.1(General) |
- |
500 |
|
- |
| Cl-16.2(Test for Measuring the Insulation Resistance) |
- |
1000 |
|
- |
| Cl-16.3(Electric Strength Test) |
- |
1000 |
|
- |
| Cl-17(Temperature rise) |
- |
1500 |
|
- |
| Cl-18(Making and breaking capacity) |
- |
1000 |
|
- |
| Cl-19(Normal operation) |
- |
1500 |
|
- |
| Cl-20(Mechanical strength) |
- |
1000 |
|
- |
| Cl-21(Resistance to heat) |
- |
1000 |
|
- |
| Cl-22(Screws, current carrying parts and connections) |
- |
1000 |
|
- |
| Cl-23(Creepage distances, clearances and distance through sealing compound) |
- |
700 |
|
- |
| Cl-24.1(Resistance to abnormal heat and fire) |
- |
1500 |
|
- |
| Cl-24.2(Resistance to tracking) |
- |
1500 |
|
- |
| Cl-25(Resistance to rusting) |
- |
1000 |
|
- |
| 19.1(Test for Switches Intended for Inductive Loads) |
- |
1000 |
|
- |
| 19.2(Test for Switches Intended for Externally Ballasted Lamp Loads) |
- |
1000 |
|
- |
| 19.3(Test for Switches Intended for Self-ballasted Lamp Loads) |
- |
1000 |
|
- |
| 13.5(Attachment of knobs) |
- |
1500 |
|
- |
| 12.3.11(Table 11)(Test Current for the Verification of Electrical and Thermal Stresses in Normal Use of Screwless Terminals) |
- |
1000 |
|
- |
| 12.3.12(Table 13)(Deflection Test Forces) |
- |
1000 |
|
- |
| Cl-7(Classification) |
- |
500 |
|
- |
| Cl-4(General Requirements) |
- |
500 |
|
- |
| Cl-5(General notes on tests) |
- |
0 |
|
- |
| Cl-6(Rating) |
- |
500 |
|
- |
| Cl-8(Marking) |
- |
700 |
|
- |
| Cl-9(Checking of dimensions) |
- |
700 |
|
- |
| Cl-10.1, 10.2(Prevention of Access to Live Parts) |
- |
500 |
|
- |
| Cl-10.3(Requirements for Accessible Metal Parts) |
- |
500 |
|
- |
| Cl-10.4(Requirements for Insulation of the Mechanism) |
- |
500 |
|
- |
| Cl. 10.5(Requirements for Insulation of the Mechanism with Respect to the Surrounding Environment) |
- |
500 |
|
- |
| Cl-10.6(Requirements for Switches Operated Indirectly) |
- |
500 |
|
- |
| Cl-10.7(Requirements for Switches with Replaceable Pull Cord) |
- |
500 |
|
- |
| Cl-11(Provision for earthing) |
- |
1000 |
|
- |
| Cl-12(Terminals) |
- |
1000 |
|
- |
| Cl-13(Constructional requirements) |
- |
1500 |
|
- |
| Cl-14(Mechanism) |
- |
1000 |
|
- |
| Cl-15.1(Resistance to Ageing) |
- |
2000 |
|
- |
| Cl-15.2(Protection Provided by Enclosures of Switches) |
- |
1000 |
|
- |
| Cl-15.3(Resistance to Humidity) |
- |
1500 |
|
- |
| Cl-16.1(General) |
- |
500 |
|
- |
| Cl-16.2(Test for Measuring the Insulation Resistance) |
- |
1000 |
|
- |
| Cl-16.3(Electric Strength Test) |
- |
1000 |
|
- |
| Cl-17(Temperature rise) |
- |
1500 |
|
- |
| Cl-18(Making and breaking capacity) |
- |
1000 |
|
- |
| Cl-19(Normal operation) |
- |
1500 |
|
- |
| Cl-20(Mechanical strength) |
- |
1000 |
|
- |
| Cl-21(Resistance to heat) |
- |
1000 |
|
- |
| Cl-22(Screws, current carrying parts and connections) |
- |
1000 |
|
- |
| Cl-23(Creepage distances, clearances and distance through sealing compound) |
- |
700 |
|
- |
| Cl-24.1(Resistance to abnormal heat and fire) |
- |
1500 |
|
- |
| Cl-24.2(Resistance to tracking) |
- |
1500 |
|
- |
| Cl-25(Resistance to rusting) |
- |
1000 |
|
- |
| 19.1(Test for Switches Intended for Inductive Loads) |
- |
1000 |
|
- |
| 19.2(Test for Switches Intended for Externally Ballasted Lamp Loads) |
- |
1000 |
|
- |
| 19.3(Test for Switches Intended for Self-ballasted Lamp Loads) |
- |
1000 |
|
- |
| 13.5(Attachment of knobs) |
- |
1500 |
|
- |
| 12.3.11(Table 11)(Test Current for the Verification of Electrical and Thermal Stresses in Normal Use of Screwless Terminals) |
- |
1000 |
|
- |
| 12.3.12(Table 13)(Deflection Test Forces) |
- |
1000 |
|
- |
| Cl-7(Classification) |
- |
500 |
|
- |
| Cl-4(General Requirements) |
- |
0 |
|
- |
| Cl-5(General notes on tests) |
- |
0 |
|
- |
| Cl-6(Rating) |
- |
0 |
|
- |
| Cl-8(Marking) |
- |
0 |
|
- |
| Cl-9(Checking of dimensions) |
- |
0 |
|
- |
| Cl-10.1, 10.2(Prevention of Access to Live Parts) |
- |
0 |
|
- |
| Cl-10.3(Requirements for Accessible Metal Parts) |
- |
0 |
|
- |
| Cl-10.4(Requirements for Insulation of the Mechanism) |
- |
0 |
|
- |
| Cl. 10.5(Requirements for Insulation of the Mechanism with Respect to the Surrounding Environment) |
- |
0 |
|
- |
| Cl-10.6(Requirements for Switches Operated Indirectly) |
- |
0 |
|
- |
| Cl-10.7(Requirements for Switches with Replaceable Pull Cord) |
- |
0 |
|
- |
| Cl-11(Provision for earthing) |
- |
0 |
|
- |
| Cl-12(Terminals) |
- |
0 |
|
- |
| Cl-13(Constructional requirements) |
- |
0 |
|
- |
| Cl-14(Mechanism) |
- |
0 |
|
- |
| Cl-15.1(Resistance to Ageing) |
- |
0 |
|
- |
| Cl-15.2(Protection Provided by Enclosures of Switches) |
- |
0 |
|
- |
| Cl-15.3(Resistance to Humidity) |
- |
0 |
|
- |
| Cl-16.1(General) |
- |
0 |
|
- |
| Cl-16.2(Test for Measuring the Insulation Resistance) |
- |
0 |
|
- |
| Cl-16.3(Electric Strength Test) |
- |
0 |
|
- |
| Cl-17(Temperature rise) |
- |
0 |
|
- |
| Cl-18(Making and breaking capacity) |
- |
0 |
|
- |
| Cl-19(Normal operation) |
- |
0 |
|
- |
| Cl-20(Mechanical strength) |
- |
0 |
|
- |
| Cl-21(Resistance to heat) |
- |
0 |
|
- |
| Cl-22(Screws, current carrying parts and connections) |
- |
0 |
|
- |
| Cl-23(Creepage distances, clearances and distance through sealing compound) |
- |
0 |
|
- |
| Cl-24.1(Resistance to abnormal heat and fire) |
- |
0 |
|
- |
| Cl-24.2(Resistance to tracking) |
- |
0 |
|
- |
| Cl-25(Resistance to rusting) |
- |
0 |
|
- |
| 19.1(Test for Switches Intended for Inductive Loads) |
- |
0 |
|
- |
| 19.2(Test for Switches Intended for Externally Ballasted Lamp Loads) |
- |
0 |
|
- |
| 19.3(Test for Switches Intended for Self-ballasted Lamp Loads) |
- |
0 |
|
- |
| 13.5(Attachment of knobs) |
- |
0 |
|
- |
| 12.3.11(Table 11)(Test Current for the Verification of Electrical and Thermal Stresses in Normal Use of Screwless Terminals) |
- |
0 |
|
- |
| 12.3.12(Table 13)(Deflection Test Forces) |
- |
0 |
|
- |
| Cl-7(Classification) |
- |
0 |
|
- |
| Cl-4(General Requirements) |
- |
0 |
|
- |
| Cl-5(General notes on tests) |
- |
0 |
|
- |
| Cl-6(Rating) |
- |
0 |
|
- |
| Cl-8(Marking) |
- |
0 |
|
- |
| Cl-9(Checking of dimensions) |
- |
0 |
|
- |
| Cl-10.1, 10.2(Prevention of Access to Live Parts) |
- |
0 |
|
- |
| Cl-10.3(Requirements for Accessible Metal Parts) |
- |
0 |
|
- |
| Cl-10.4(Requirements for Insulation of the Mechanism) |
- |
0 |
|
- |
| Cl. 10.5(Requirements for Insulation of the Mechanism with Respect to the Surrounding Environment) |
- |
0 |
|
- |
| Cl-10.6(Requirements for Switches Operated Indirectly) |
- |
0 |
|
- |
| Cl-10.7(Requirements for Switches with Replaceable Pull Cord) |
- |
0 |
|
- |
| Cl-11(Provision for earthing) |
- |
0 |
|
- |
| Cl-12(Terminals) |
- |
0 |
|
- |
| Cl-13(Constructional requirements) |
- |
0 |
|
- |
| Cl-14(Mechanism) |
- |
0 |
|
- |
| Cl-15.1(Resistance to Ageing) |
- |
0 |
|
- |
| Cl-15.2(Protection Provided by Enclosures of Switches) |
- |
0 |
|
- |
| Cl-15.3(Resistance to Humidity) |
- |
0 |
|
- |
| Cl-16.1(General) |
- |
0 |
|
- |
| Cl-16.2(Test for Measuring the Insulation Resistance) |
- |
0 |
|
- |
| Cl-16.3(Electric Strength Test) |
- |
0 |
|
- |
| Cl-17(Temperature rise) |
- |
0 |
|
- |
| Cl-18(Making and breaking capacity) |
- |
0 |
|
- |
| Cl-19(Normal operation) |
- |
0 |
|
- |
| Cl-20(Mechanical strength) |
- |
0 |
|
- |
| Cl-21(Resistance to heat) |
- |
0 |
|
- |
| Cl-22(Screws, current carrying parts and connections) |
- |
0 |
|
- |
| Cl-23(Creepage distances, clearances and distance through sealing compound) |
- |
0 |
|
- |
| Cl-24.1(Resistance to abnormal heat and fire) |
- |
0 |
|
- |
| Cl-24.2(Resistance to tracking) |
- |
0 |
|
- |
| Cl-25(Resistance to rusting) |
- |
0 |
|
- |
| 19.1(Test for Switches Intended for Inductive Loads) |
- |
0 |
|
- |
| 19.2(Test for Switches Intended for Externally Ballasted Lamp Loads) |
- |
0 |
|
- |
| 19.3(Test for Switches Intended for Self-ballasted Lamp Loads) |
- |
0 |
|
- |
| 13.5(Attachment of knobs) |
- |
0 |
|
- |
| 12.3.11(Table 11)(Test Current for the Verification of Electrical and Thermal Stresses in Normal Use of Screwless Terminals) |
- |
0 |
|
- |
| 12.3.12(Table 13)(Deflection Test Forces) |
- |
0 |
|
- |
| Cl-7(Classification) |
- |
0 |
|
- |
|
28 Aug, 2027 |
- - |
| 9653 |
WELL TECH TEST AND RESEARCH CENTER, DERABASSI
| 9177306
| IS 7092 : Part 1 (1992) |
Aluminium alloy tubes for irrigation purposes - Specification: Part 1 welded tubes (Second Revision) |
WELDED TUBES AS PER TABLE 1 |
17000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 10(Marking) |
- |
1000 |
|
- |
| 5(Workmanship and Finish) |
- |
1000 |
|
- |
| 8(Dimensions) |
- |
3000 |
|
- |
| 7.2(Mechanical properties) |
- |
5000 |
|
- |
| 7.3(Flattening test) |
- |
3000 |
|
- |
| 7.4(Hydrostatic test) |
- |
4000 |
|
- |
| 10(Marking) |
- |
0 |
|
TEST FACILITY FOR CHEMICAL ANALYSIS IS AVAILABLE AND TESTING CHARGES ARE 3500/- |
| 5(Workmanship and Finish) |
- |
0 |
|
- |
| 8(Dimensions) |
- |
0 |
|
- |
| 7.2(Mechanical properties) |
- |
0 |
|
- |
| 7.3(Flattening test) |
- |
0 |
|
- |
| 7.4(Hydrostatic test) |
- |
0 |
|
- |
|
30 Mar, 2027 |
- Included w.e.f 07.01.2025 |
| 9654 |
SGS India Private Limited-Multilaboratory, Chennai
| 6114716
| IS 14543 (2024) |
Packaged Drinking Water Other than Packaged Natural Mineral Water Specification Third Revision |
- |
15250 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 5.3(Appearance) |
- |
0 |
|
- |
| 5.4/Annex D/i(P,P-DDT) |
- |
0 |
|
- |
| 5.4/Annex D/ii(Lindane) |
- |
0 |
|
- |
| 5.4/Annex D/iv(b-Endosulfan) |
- |
0 |
|
- |
| 5.4/Annex D/xvi(Dieldrin) |
- |
0 |
|
- |
| 5.4/Annex D/xvi(Aldrin) |
- |
0 |
|
- |
| 5.4/Annex D/i(O,P-DDT) |
- |
0 |
|
- |
| 5.4/Annex D/iv(a-Endosulfan) |
- |
0 |
|
- |
| 5.4/Annex D/iii(d-HCH) |
- |
0 |
|
- |
| 5.4/Annex D/i(O,P-DDD) |
- |
0 |
|
- |
| 5.4/Annex D/i(P,P-DDE) |
- |
0 |
|
- |
| 5.4/Annex D/iii(a-HCH) |
- |
0 |
|
- |
| 5.4/Annex D/iii(β- HCH) |
- |
0 |
|
- |
| 5.4/Annex D/iv(Endosulfan sulfate) |
- |
0 |
|
- |
| 5.4/Annex D/i(P,P-DDD) |
- |
0 |
|
- |
| 5.4/Annex D/xii(Alachlor) |
- |
0 |
|
- |
| 5.4/Annex D/vii(Chlorpyrifos) |
- |
0 |
|
- |
| 5.4/Annex D/x(Butachlor) |
- |
0 |
|
- |
| 5.4/Annex D/vi(Ethion) |
- |
0 |
|
- |
| 5.4/Annex D/xiv(Methyl parathion) |
- |
0 |
|
- |
| 5.4/Annex D/xv(Malathion) |
- |
0 |
|
- |
| 5.4/Annex D/viii(Phorate) |
- |
0 |
|
- |
| 5.4/Annex D/v(Monochrotophos) |
- |
0 |
|
- |
| 5.4/Annex D/xiii(Atrazine) |
- |
0 |
|
- |
| 5.4/Annex D/viii(Phorate sulphoxide) |
- |
0 |
|
- |
| 5.4/Annex D/viii(Phorate sulfone) |
- |
0 |
|
- |
| 5.4/Annex D/xxvii(Methyl paraoxon) |
- |
0 |
|
- |
| 5.4/Annex D/xxviii(Malaoxon) |
- |
0 |
|
- |
| 5.4/Annex D/xi(Isoproturon) |
- |
0 |
|
- |
| 5.4/Annex D/ix(2,4 –D) |
- |
0 |
|
- |
| Cl-5.2.1(Escherichia coli or thermotolerant bacteria) |
- |
300 |
|
- |
| Cl-5.2.2(Coliform) |
- |
150 |
|
- |
| Cl-5.2.3(Staphylococcus aureus) |
- |
375 |
|
- |
| Cl-5.2.4(Sulphite Reducing Anaerobes) |
- |
150 |
|
- |
| Cl-5.2.5(Pseudomonas Aeruginosa) |
- |
300 |
|
- |
| Cl-5.2.6(Aerobic Microbial Count @ 37 deg C) |
- |
150 |
|
- |
| Cl-5.2.7(Yeast and mould) |
- |
150 |
|
- |
| Cl-5.2.8(Salmonella) |
- |
675.99 |
|
- |
| Cl-5.2.9(Vibrio cholera) |
- |
450 |
|
- |
| Cl-5.3, Table-1 (i)(Colour, true colour units, Max) |
- |
75 |
|
- |
| Cl-5.3, Table-1 (ii)(Odour) |
- |
37.5 |
|
- |
| Cl-5.3, Table-1 (iii)(Taste) |
- |
37.5 |
|
- |
| Cl-5.3, Table-1 (iv)(Turbidity, nephelometric turbidity unit (NTU), Max) |
- |
37.5 |
|
- |
| Cl-5.3, Table-1 (v)(Total dissolved solids, mg/l, Max) |
- |
75 |
|
- |
| Cl-5.3, Table-1 (vi)(pH) |
- |
37.5 |
|
- |
| Cl-5.3, Table-2 (i)(Barium (as Ba)) |
- |
150 |
|
- |
| Cl-5.3, Table-2 (ii)(Copper (as Cu)) |
- |
75 |
|
- |
| Cl-5.3, Table-2 (iii)(Iron (as Fe)) |
- |
75 |
|
- |
| Cl-5.3, Table-2 (iv)(Manganese (as Mn)) |
- |
75 |
|
- |
| Cl-5.3, Table-2 (v)(Nitrate (as NO3 )) |
- |
300 |
|
- |
| Cl-5.3, Table-2 (vi)(Nitrite (as NO2 )) |
- |
225 |
|
- |
| Cl-5.3, Table-2 (vii)(Fluoride (as F)) |
- |
150 |
|
- |
| Cl-5.3, Table-2 (viii)(Zinc (as Zn)) |
- |
75 |
|
- |
| Cl-5.3, Table-2 (ix)(Silver (as Ag)) |
- |
75 |
|
- |
| Cl-5.3, Table-2 (x)(Aluminium (as A1)) |
- |
75 |
|
- |
| Cl-5.3, Table-2 (xi)(Chloride (as Cl)) |
- |
75 |
|
- |
| Cl-5.3, Table-2 (xii)(Selenium (as Se)) |
- |
150 |
|
- |
| Cl-5.3, Table-2 (xiii)(Sulphate (as SO4 )) |
- |
150 |
|
- |
| Cl-5.3, Table-2 (xiv)(Alkalinity (as HCO3 )) |
- |
75 |
|
- |
| Cl-5.3, Table-2 (xv)(Calcium (as Ca)) |
- |
75 |
|
- |
| Cl-5.3, Table-2 (xvi)(Magnesium (as Mg)) |
- |
75 |
|
- |
| Cl-5.3, Table-2 (xvii)(Sodium (as Na)) |
- |
75 |
|
- |
| Cl-5.3, Table-2 (xviii)(Residual free chlorine) |
- |
75 |
|
- |
| Cl-5.3, Table-2 (xix)(Phenolic compounds (as C6H5OH)) |
- |
300 |
|
- |
| Cl-5.3, Table-2 (xx)(Mineral oil) |
- |
75 |
|
- |
| Cl-5.3, Table-2 (xxi)(Anionic surface active agents) |
- |
375 |
|
- |
| Cl-5.3, Table-2 (xxii)(Sulphide) |
- |
150 |
|
- |
| Cl-5.3, Table-2 (xxiii)(Antimony (as Sb)) |
- |
149.99 |
|
- |
| Cl-5.3, Table-2 (xxiv)(Borates (as B)) |
- |
150 |
|
- |
| Cl-5.3, Table-2 (xxv)(Bromates (as BrO3 )) |
- |
2500 |
|
- |
| Cl-5.3, Table-3 (i)(Mercury (as Hg)) |
- |
150 |
|
- |
| Cl-5.3, Table-3 (ii)(Cadmium (as Cd)) |
- |
150 |
|
- |
| Cl-5.3, Table-3 (iii)(Arsenic (as As)) |
- |
150 |
|
- |
| Cl-5.3, Table-3 (iv)(Cyanide (as CN)) |
- |
75 |
|
- |
| Cl-5.3, Table-3 (v)(Lead (as Pb)) |
- |
150 |
|
- |
| Cl-5.3, Table-3 (vi)(Chromium (as Cr)) |
- |
75 |
|
- |
| Cl-5.3, Table-3 (vii)(Nickel (as Ni)) |
- |
75 |
|
- |
| Cl-5.3, Table-3 (viii)(Polychlorinated biphenyl (PCB)) |
- |
300 |
|
- |
| Cl-5.3, Table-3 (ix)(Polynuclear aromatic hydrocarbons) |
- |
450 |
|
- |
| Cl-5.3, Table-3 (x)(Uranium) |
- |
750 |
|
- |
| Cl-5.2.3(Faecal streptococci) |
- |
0 |
|
- |
| Cl-5.2.8(shigella) |
- |
0 |
|
- |
| Cl-5.2.9(V.parahaemolyticus) |
- |
0 |
|
- |
| 5.2.6(Aerobic Microbial Count @ 20 to 22 deg C) |
- |
0 |
|
- |
| 5.4 i)(Dieldrin) |
- |
0 |
|
- |
| 5.4 i)(Aldrin) |
- |
0 |
|
- |
| 5.4 i)(Malathion) |
- |
0 |
|
- |
| 5.4, i)("oxygen analogue of Malathion (Malaoxon)") |
- |
0 |
|
- |
| 5.4 i)(Methyl Paraoxon) |
- |
0 |
|
- |
| 5.4 i)(Methyl Parathion) |
- |
0 |
|
- |
| 5.4 i)(Atrazine) |
- |
0 |
|
- |
| 5.4 i)(Alachlor) |
- |
0 |
|
- |
| 5.4 i)(Isoproturon) |
- |
0 |
|
- |
| 5.4 i)(Butachlor) |
- |
0 |
|
- |
| 5.4 i)(2,4-D) |
- |
0 |
|
- |
| 5.4 i)(Phorate sulphone) |
- |
0 |
|
- |
| 5.4 i)(Phorate sulphoxide) |
- |
0 |
|
- |
| 5.4 i)(Phorate) |
- |
0 |
|
- |
| 5.4 i)(Chlorpyrifos) |
- |
0 |
|
- |
| 5.4 i)(Ethion) |
- |
0 |
|
- |
| 5.4 i)(Monocrotophos) |
- |
0 |
|
- |
| 5.4 i)(Endosulfan Sulphate) |
- |
0 |
|
- |
| 5.4 i)(beta-Endosulfan) |
- |
0 |
|
- |
| 5.4 i)(alpha-Endosulfan) |
- |
0 |
|
- |
| 5.4 i)(Delta-HCH) |
- |
0 |
|
- |
| 5.4 i)(beta-HCH) |
- |
0 |
|
- |
| 5.4 i)(alpha-HCH) |
- |
0 |
|
- |
| 5.4 i)(Gamma-HCH (Lindane)) |
- |
0 |
|
- |
| 5.4 i)(p,p DDD) |
- |
0 |
|
- |
| 5.4 i)(o,p DDD) |
- |
0 |
|
- |
| 5.4 i)(p,p DDE) |
- |
0 |
|
- |
| 5.4, i)(o,p DDE) |
- |
0 |
|
- |
| 5.4 i)(p,p DDT) |
- |
0 |
|
- |
| 5.4 i)(o,p DDT) |
- |
0 |
|
- |
| Table 3, x)(Uranium) |
- |
750 |
|
- |
| Cl-5.1(General Requirements) |
- |
0 |
|
- |
| Cl-5.4 (i)(Pesticide residues considered individually) |
- |
0 |
|
- |
| Cl-5.4 (ii)(Total pesticide residue) |
- |
2775 |
|
- |
| 5.4/Annex D/i(O,P-DDE) |
- |
0 |
|
- |
|
14 Feb, 2028 |
- Included w.e.f 30.04.2025
Exclusion: Cl-5.3, Table-4 (i) (Alpha emitters, Becquerel (Bq/l)), Cl-5.3, Table-4 (ii) (Beta emitters, Becquerel (Bq/l),) |
| 9655 |
International Testing Centre, MSME Technology Development Centre, Meerut
| 8177804
| IS 15844 : Part 3 (2024) |
Sports Footwear Part 3 Professional Sports Footwear |
- |
55000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl-6(Size and Fittings) |
- |
300 |
|
- |
| Cl-5(Design) |
- |
300 |
|
- |
| Cl-6(Size and Fittings) |
- |
300 |
|
- |
| Cl.7.1.1(Upper to Mid Sole/Out Sole, Upper to Composite Sole (Applicable Only When the Sole is Composite) and Out Sole to Mid Sole (Multilayer, if Present), Bond Performance) |
- |
500 |
|
- |
| Cl.7.1.2(Energy Absorption at Seat Region) |
- |
500 |
|
- |
| Cl.7.1.1(Upper to Mid Sole/Out Sole, Upper to Composite Sole (Applicable Only When the Sole is Composite) and Out Sole to Mid Sole (Multilayer, if Present), Bond Performance) |
- |
300 |
|
- |
| Cl.7.1.2(Energy Absorption at Seat Region) |
- |
500 |
|
- |
| Cl.7.1.3(Complete Shoe Flexing) |
- |
1000 |
|
- |
| Cl.7.1.4(Washability) |
- |
500 |
|
- |
| Cl.7.1.5(Slip Resistance) |
- |
1500 |
|
- |
| Cl.7.1.6(Heel Drop) |
- |
300 |
|
- |
| Cl.7.2 Table-2 S.No- (ii)(Tear strength (average force), N, Min) |
- |
500 |
|
- |
| Cl.7.2 Table-2 S.No- (i)("Flexing resistance, Min
a) Dry condition
b) Wet condition") |
- |
1000 |
|
- |
| Cl.7.2 Table-2 S.No- (iii)("Colour fastness rubbing
a-Dry
b-Wet") |
- |
500 |
|
- |
| Cl.7.2 Table-2 S.No- (iv)("a) Water vapour permeability
b) Water vapour coefficient") |
- |
1000 |
|
- |
| Cl.7.2 Table-2 S.No- (v)(Stitch tear strength N/mm, Min) |
- |
500 |
|
- |
| Cl.7.2 Table-2 S.No- (vi)(Colour fastness to light grey scale rate) |
- |
500 |
|
- |
| Cl.7.2 Table-2 S.No- (vii)(Tensile strength) |
- |
500 |
|
- |
| Cl.7.2 Table-2 S.No- (viii)(Elongation at break, percent) |
- |
500 |
|
- |
| Cl.7.2 Table-2 S.No- (ix)("Abrasion test
a) Dry
b) Wet") |
- |
1000 |
|
- |
| Cl.7.2 Table-3 S.No- (i)(Breaking strength, N/mm, Min) |
- |
500 |
|
- |
| Cl.7.2 Table-3 S.No- (ii)(Elongation at break, percent, Min) |
- |
500 |
|
- |
| Cl.7.2 Table-3 S.No- (iii)(Tear strength, N, Min) |
- |
500 |
|
- |
| Cl.7.2 Table-3 S.No- (iv)(Strength at needle perforation) |
- |
500 |
|
- |
| Cl.7.2 Table-3 S.No- (v)("Flexing resistance
a-Dry condition, b) Wet condition") |
- |
800 |
|
- |
| Cl.7.2 Table-3 S.No- (vi)("a) Water vapour permeability
b) Water vapour coefficient") |
- |
1000 |
|
- |
| Cl.7.2 Table-3 S.No- (vii)(Hydrolysis resistance) |
- |
500 |
|
- |
| Cl.7.2 Table-3 S.No- (viii)(Colour fastness to light grey scale rate) |
- |
500 |
|
- |
| Cl.7.2 Table-3 S.No- (ix)(Bursting strength) |
- |
500 |
|
- |
| Cl.7.3 Table-4 S.No- (i)(Tear strength, N, Min) |
- |
500 |
|
- |
| Cl.7.3 Table-4 S.No- (ii)("Abrasion resistance,
a) Dry
b) Wet
") |
- |
800 |
|
- |
| Cl.7.3 Table-4 S.No- (iii)(Colour fastness to rubbing, grey scale rate with 10 rubs on dry or wet, Min) |
- |
500 |
|
- |
| Cl.7.3 Table-4 S.No- (iv)(Colour fastness to perspiration (contact method) grey scale rate, Min) |
- |
500 |
|
- |
| Cl.7.3 Table-4 S.No- (v)("a-Water vapour permeability
b-Water vapour coefficient") |
- |
500 |
|
- |
| Cl.7.4 Table-5 S.No- (ii)(Abrasion resistance) |
- |
800 |
|
- |
| Cl.7.4 Table-5 S.No- (iii)("a) Water absorption
b) Water desorption") |
- |
800 |
|
- |
| Cl.7.5 Table-6 S.No- (i)("Abrasion resistance
a) Dry condition
b) Wet condition") |
- |
800 |
|
- |
| Cl.7.5 Table-6 S.No- (ii)("a) Water absorption
b) Water desorption") |
- |
1000 |
|
- |
| Cl.7.5 Table-6 S.No- (iii)(Heat resistance shrinkage linear, percent, Max) |
- |
500 |
|
- |
| Cl.7.6 Table-7 S.No- (i)(Abrasion resistance) |
- |
500 |
|
- |
| Cl.7.6 Table-7 S.No- (ii)("Flexing resistance
a) Bennewart Method
b) Ross flexing method") |
- |
1000 |
|
- |
| Cl.7.6 Table-7 S.No- (iii)(Hydrolysis resistance) |
- |
2000 |
|
- |
| Cl.7.6 Table-7 S.No- (iv)(Tear strength, N/mm, Min) |
- |
500 |
|
- |
| Cl.7.6 Table-7 S.No- (v)(Tensile strength) |
- |
500 |
|
- |
| Cl.7.6 Table-7 S.No- (vi)(Elongation at break percent, Min) |
- |
500 |
|
- |
| Cl.7.6 Table-7 S.No- (vii)(Compression set percent, Max) |
- |
800 |
|
- |
| Cl.7.7 Table-8 S.No- (i)("Compression set, percent, Max
a) For EVA
b) For all other material") |
- |
800 |
|
- |
| Cl.7.7 Table-8 S.No- (ii)(Split tear strength) |
- |
500 |
|
- |
| Cl.7.7 Table-8 S.No- (iii)(Heat shrinkage, percent, Ma) |
- |
1000 |
|
- |
| Cl.7.7 Table-8 S.No- (iv)(Elongation at break, percent, Min) |
- |
500 |
|
- |
| Cl.7.8 Table-9 S.No- (i)(First dry collapsing load, hardness, N, Min) |
- |
1000 |
|
- |
| Cl.7.8 Table-9 S.No- (ii)(Resilience, percent, Min) |
- |
500 |
|
- |
| Cl.7.8 Table-9 S.No- (iii)(Moisture resistance, percent, Min) |
- |
1700 |
|
- |
| Cl.7.8 Table-9 S.No- (v)(Peel strength, N/nm, Min) |
- |
500 |
|
- |
| Cl.7.9 Table-10 S.No- (i)("Peel strength, N/mm, Min
a) Initial
b) After 5 000 wear cycles") |
- |
500 |
|
- |
| Cl.7.9 Table-10 S.No- (ii)("Shear strength, kPa, Min
a) Initial
b) After 5 000 wear cycles") |
- |
500 |
|
- |
| Cl.7.10 Table-11 S.No- (i)(Limit of useful extension, percent, Min) |
- |
500 |
|
- |
| Cl.7.10 Table-11 S.No- (ii)(Needle strength, N/mm, Min) |
- |
500 |
|
- |
| Cl.7.11 Table-12 S.No- (i)(Breaking strength of lace) |
- |
500 |
|
- |
| Cl.7.11 Table-12 S.No- (ii)(Lace tag strength) |
- |
500 |
|
- |
| Cl.7.11 Table-12 S.No- (iii)(Lace to lace abrasion) |
- |
500 |
|
- |
| Cl.7.11 Table-12 S.No- (iv)(Colour fastness to water (for lace) (Contact method)) |
- |
500 |
|
- |
| Cl.7.11 Table-12 S.No- (v)(Strength of buckle/ski hook/D-ring,) |
- |
500 |
|
- |
| Cl.7.11 Table-12 S.No- (vi)("Corrosion resistance (applicable for all including decorative metal part)
") |
- |
500 |
|
- |
| Cl.7.11 Table-13 S.No- (i)(Corrosion resistance (applicable for metallic spikes)) |
- |
500 |
|
- |
| Cl-7.12.1, Table no. 1 of IS 17011,(i)(Allergenic and carcinogenic disperse dyes) |
- |
3000 |
|
- |
| Cl-7.12.1, Table no. 1 of IS 17011,(ii)(Aromatic amines released from Azo dyes (each individual amine)) |
- |
3000 |
|
- |
| Cl-7.12.1, Table no. 1 of IS 17011,(iii)(Aromatic amines released from Azo dyes (each individual amine)) |
- |
3000 |
|
- |
| Cl-7.12.1, Table no. 1 of IS 17011,(iv)(Chromium (VI)) |
- |
2000 |
|
- |
| Cl-7.12.1, Table no. 1 of IS 17011,(v)(Dimethyl fumarate (DMFU)) |
- |
2000 |
|
- |
| Cl-7.12.1, Table no. 1 of IS 17011,(vi)(Formaldehyde (free or released by partial hydrolysis)) |
- |
2000 |
|
- |
| Cl-7.12.1, Table no. 1 of IS 17011,(vii)(Formaldehyde) |
- |
2000 |
|
- |
| Cl-7.12.1, Table no. 1 of IS 17011,(viii)(Organotin compounds) |
- |
4500 |
|
- |
| Cl-7.12.1, Table no. 1 of IS 17011,(ix)(PCP-TeCP-TriCP polychlorophenols) |
- |
3000 |
|
- |
| Cl-7.12.1, Table no. 1 of IS 17011,(viii)(Organotin compounds) |
- |
4500 |
|
- |
| Cl-7.12.1, Table no. 1 of IS 17011,(vi)(Formaldehyde (free or released by partial hydrolysis)) |
- |
2000 |
|
- |
| Cl-7.12.1, Table no. 1 of IS 17011,(v)(Dimethyl fumarate (DMFU)) |
- |
2000 |
|
- |
| Cl-7.12.1, Table no. 1 of IS 17011,(iv)(Chromium (VI)) |
- |
2000 |
|
- |
| Cl-7.12.1, Table no. 1 of IS 17011,(x)(pH) |
- |
500 |
|
- |
| Cl-7.12.1, Table no. 1 of IS 17011,(xi)(Phthalates (each individual phthalate)) |
- |
4500 |
|
- |
| C-7.12.1, Table no. 1 of IS 17011,(xii)(Nickel, on skin contact 2-(thiocyanomethylthio) -benzothiazole (TCMTB)) |
- |
1000 |
|
- |
| Cl-7.12.2(PVC is present in sports shoe) |
- |
2000 |
|
- |
| Cl- 8.1(Marking) |
- |
300 |
|
- |
| Cl.7.7 Table-8 S.No- (iii)(Elongation at break, percent, Min) |
- |
500 |
|
- |
| Cl.7.8 Table-9 S.No- (iv)("a) Initial dry area shape retention, percent, Min
b) Area shape retention after 10th
collapse, dry, percent, Min
") |
- |
500 |
|
- |
| Cl-6(Size and Fittings) |
- |
300 |
|
- |
| Cl-5(Design) |
- |
300 |
|
- |
| Cl-6(Size and Fittings) |
- |
300 |
|
- |
| Cl.7.1.1(Upper to Mid Sole/Out Sole, Upper to Composite Sole (Applicable Only When the Sole is Composite) and Out Sole to Mid Sole (Multilayer, if Present), Bond Performance) |
- |
500 |
|
- |
| Cl.7.1.2(Energy Absorption at Seat Region) |
- |
500 |
|
- |
| Cl.7.1.1(Upper to Mid Sole/Out Sole, Upper to Composite Sole (Applicable Only When the Sole is Composite) and Out Sole to Mid Sole (Multilayer, if Present), Bond Performance) |
- |
500 |
|
- |
| Cl.7.1.2(Energy Absorption at Seat Region) |
- |
500 |
|
- |
| Cl.7.1.3(Complete Shoe Flexing) |
- |
1500 |
|
- |
| Cl.7.1.4(Washability) |
- |
1000 |
|
- |
| Cl.7.1.5(Slip Resistance) |
- |
1500 |
|
- |
| Cl.7.1.6(Heel Drop) |
- |
300 |
|
- |
| Cl.7.2 Table-2 S.No- (ii)(Tear strength (average force), N, Min) |
- |
500 |
|
- |
| Cl.7.2 Table-2 S.No- (i)("Flexing resistance, Min
a) Dry condition
b) Wet condition") |
- |
1500 |
|
- |
| Cl.7.2 Table-2 S.No- (iii)("Colour fastness rubbing
a-Dry
b-Wet") |
- |
500 |
|
- |
| Cl.7.2 Table-2 S.No- (iv)("a) Water vapour permeability
b) Water vapour coefficient") |
- |
500 |
|
- |
| Cl.7.2 Table-2 S.No- (v)(Stitch tear strength N/mm, Min) |
- |
500 |
|
- |
| Cl.7.2 Table-2 S.No- (vi)(Colour fastness to light grey scale rate) |
- |
500 |
|
- |
| Cl.7.2 Table-2 S.No- (vii)(Tensile strength) |
- |
500 |
|
- |
| Cl.7.2 Table-2 S.No- (viii)(Elongation at break, percent) |
- |
500 |
|
- |
| Cl.7.2 Table-2 S.No- (ix)("Abrasion test
a) Dry
b) Wet") |
- |
800 |
|
- |
| Cl.7.2 Table-3 S.No- (i)(Breaking strength, N/mm, Min) |
- |
500 |
|
- |
| Cl.7.2 Table-3 S.No- (ii)(Elongation at break, percent, Min) |
- |
500 |
|
- |
| Cl.7.2 Table-3 S.No- (iii)(Tear strength, N, Min) |
- |
500 |
|
- |
| Cl.7.2 Table-3 S.No- (iv)(Strength at needle perforation) |
- |
500 |
|
- |
| Cl.7.2 Table-3 S.No- (v)("Flexing resistance
a-Dry condition, b) Wet condition") |
- |
800 |
|
- |
| Cl.7.2 Table-3 S.No- (vi)("a) Water vapour permeability
b) Water vapour coefficient") |
- |
800 |
|
- |
| Cl.7.2 Table-3 S.No- (vii)(Hydrolysis resistance) |
- |
1500 |
|
- |
| Cl.7.2 Table-3 S.No- (viii)(Colour fastness to light grey scale rate) |
- |
500 |
|
- |
| Cl.7.2 Table-3 S.No- (ix)(Bursting strength) |
- |
500 |
|
- |
| Cl.7.3 Table-4 S.No- (i)(Tear strength, N, Min) |
- |
500 |
|
- |
| Cl.7.3 Table-4 S.No- (ii)("Abrasion resistance,
a) Dry
b) Wet
") |
- |
800 |
|
- |
| Cl.7.3 Table-4 S.No- (iii)(Colour fastness to rubbing, grey scale rate with 10 rubs on dry or wet, Min) |
- |
500 |
|
- |
| Cl.7.3 Table-4 S.No- (iv)(Colour fastness to perspiration (contact method) grey scale rate, Min) |
- |
500 |
|
- |
| Cl.7.3 Table-4 S.No- (v)("a-Water vapour permeability
b-Water vapour coefficient") |
- |
500 |
|
- |
| Cl.7.4 Table-5 S.No- (ii)(Abrasion resistance) |
- |
800 |
|
- |
| Cl.7.4 Table-5 S.No- (iii)("a) Water absorption
b) Water desorption") |
- |
500 |
|
- |
| Cl.7.5 Table-6 S.No- (i)("Abrasion resistance
a) Dry condition
b) Wet condition") |
- |
500 |
|
- |
| Cl.7.5 Table-6 S.No- (ii)("a) Water absorption
b) Water desorption") |
- |
500 |
|
- |
| Cl.7.5 Table-6 S.No- (iii)(Heat resistance shrinkage linear, percent, Max) |
- |
800 |
|
- |
| Cl.7.6 Table-7 S.No- (i)(Abrasion resistance) |
- |
800 |
|
- |
| Cl.7.6 Table-7 S.No- (ii)("Flexing resistance
a) Bennewart Method
b) Ross flexing method") |
- |
1500 |
|
- |
| Cl.7.6 Table-7 S.No- (iii)(Hydrolysis resistance) |
- |
1500 |
|
- |
| Cl.7.6 Table-7 S.No- (iv)(Tear strength, N/mm, Min) |
- |
500 |
|
- |
| Cl.7.6 Table-7 S.No- (v)(Tensile strength) |
- |
500 |
|
- |
| Cl.7.6 Table-7 S.No- (vi)(Elongation at break percent, Min) |
- |
500 |
|
- |
| Cl.7.6 Table-7 S.No- (vii)(Compression set percent, Max) |
- |
800 |
|
- |
| Cl.7.7 Table-8 S.No- (i)("Compression set, percent, Max
a) For EVA
b) For all other material") |
- |
800 |
|
- |
| Cl.7.7 Table-8 S.No- (ii)(Split tear strength) |
- |
500 |
|
- |
| Cl.7.7 Table-8 S.No- (iii)(Heat shrinkage, percent, Ma) |
- |
500 |
|
- |
| Cl.7.7 Table-8 S.No- (iv)(Elongation at break, percent, Min) |
- |
500 |
|
- |
| Cl.7.8 Table-9 S.No- (i)(First dry collapsing load, hardness, N, Min) |
- |
500 |
|
- |
| Cl.7.8 Table-9 S.No- (ii)(Resilience, percent, Min) |
- |
500 |
|
- |
| Cl.7.8 Table-9 S.No- (iii)(Moisture resistance, percent, Min) |
- |
500 |
|
- |
| Cl.7.8 Table-9 S.No- (v)(Peel strength, N/nm, Min) |
- |
500 |
|
- |
| Cl.7.9 Table-10 S.No- (i)("Peel strength, N/mm, Min
a) Initial
b) After 5 000 wear cycles") |
- |
500 |
|
- |
| Cl.7.9 Table-10 S.No- (ii)("Shear strength, kPa, Min
a) Initial
b) After 5 000 wear cycles") |
- |
500 |
|
- |
| Cl.7.10 Table-11 S.No- (i)(Limit of useful extension, percent, Min) |
- |
500 |
|
- |
| Cl.7.10 Table-11 S.No- (ii)(Needle strength, N/mm, Min) |
- |
500 |
|
- |
| Cl.7.11 Table-12 S.No- (i)(Breaking strength of lace) |
- |
500 |
|
- |
| Cl.7.11 Table-12 S.No- (ii)(Lace tag strength) |
- |
500 |
|
- |
| Cl.7.11 Table-12 S.No- (iii)(Lace to lace abrasion) |
- |
500 |
|
- |
| Cl.7.11 Table-12 S.No- (iv)(Colour fastness to water (for lace) (Contact method)) |
- |
500 |
|
- |
| Cl.7.11 Table-12 S.No- (v)(Strength of buckle/ski hook/D-ring,) |
- |
500 |
|
- |
| Cl.7.11 Table-12 S.No- (vi)("Corrosion resistance (applicable for all including decorative metal part)
") |
- |
500 |
|
- |
| Cl.7.11 Table-13 S.No- (i)(Corrosion resistance (applicable for metallic spikes)) |
- |
500 |
|
- |
| Cl-7.12.1, Table no. 1 of IS 17011,(i)(Allergenic and carcinogenic disperse dyes) |
- |
3000 |
|
- |
| Cl-7.12.1, Table no. 1 of IS 17011,(ii)(Aromatic amines released from Azo dyes (each individual amine)) |
- |
3500 |
|
- |
| Cl-7.12.1, Table no. 1 of IS 17011,(iii)(Aromatic amines released from Azo dyes (each individual amine)) |
- |
3500 |
|
- |
| Cl-7.12.1, Table no. 1 of IS 17011,(iv)(Chromium (VI)) |
- |
1000 |
|
- |
| Cl-7.12.1, Table no. 1 of IS 17011,(v)(Dimethyl fumarate (DMFU)) |
- |
2000 |
|
- |
| Cl-7.12.1, Table no. 1 of IS 17011,(vi)(Formaldehyde (free or released by partial hydrolysis)) |
- |
1000 |
|
- |
| Cl-7.12.1, Table no. 1 of IS 17011,(vii)(Formaldehyde) |
- |
1000 |
|
- |
| Cl-7.12.1, Table no. 1 of IS 17011,(viii)(Organotin compounds) |
- |
3500 |
|
- |
| Cl-7.12.1, Table no. 1 of IS 17011,(ix)(PCP-TeCP-TriCP polychlorophenols) |
- |
3000 |
|
- |
| Cl-7.12.1, Table no. 1 of IS 17011,(viii)(Organotin compounds) |
- |
3000 |
|
- |
| Cl-7.12.1, Table no. 1 of IS 17011,(vi)(Formaldehyde (free or released by partial hydrolysis)) |
- |
2000 |
|
- |
| Cl-7.12.1, Table no. 1 of IS 17011,(v)(Dimethyl fumarate (DMFU)) |
- |
2000 |
|
- |
| Cl-7.12.1, Table no. 1 of IS 17011,(iv)(Chromium (VI)) |
- |
1000 |
|
- |
| Cl-7.12.1, Table no. 1 of IS 17011,(x)(pH) |
- |
500 |
|
- |
| Cl-7.12.1, Table no. 1 of IS 17011,(xi)(Phthalates (each individual phthalate)) |
- |
4500 |
|
- |
| C-7.12.1, Table no. 1 of IS 17011,(xii)(Nickel, on skin contact 2-(thiocyanomethylthio) -benzothiazole (TCMTB)) |
- |
1000 |
|
- |
| Cl-7.12.2(PVC is present in sports shoe) |
- |
500 |
|
- |
| Cl- 8.1(Marking) |
- |
300 |
|
- |
| Cl.7.7 Table-8 S.No- (iii)(Elongation at break, percent, Min) |
- |
500 |
|
- |
| Cl.7.8 Table-9 S.No- (iv)("a) Initial dry area shape retention, percent, Min
b) Area shape retention after 10th
collapse, dry, percent, Min
") |
- |
500 |
|
- |
| Cl.7.4 Table-5 S.No- (i)(Flexing index, Min) |
- |
1500 |
|
- |
|
15 Apr, 2027 |
- Included w.e.f.29.11.2024 |
| 9656 |
Stellar Test House, Noida
| 8171606
| IS 302 : Part 2 : Sec 202 (1992) |
Safety of household and similar electrical appliances: Part 2 particular requirements: Sec 202 electric stoves |
- |
14000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 6(Classification- IS 302-1 ) |
- |
50 |
|
5% Discount for BIS |
| 6(Classification- IS 302-1) |
- |
50 |
|
5% Discount for BIS |
| 7.1(Marking- IS 302-1) |
- |
50 |
|
5% Discount for BIS |
| 7.1(Marking- IS 302-1) |
- |
50 |
|
5% Discount for BIS |
| 7.1(Marking- IS 302-1) |
- |
50 |
|
5% Discount for BIS |
| 7.1(Marking- IS 302-1) |
- |
50 |
|
5% Discount for BIS |
| 7.1(Marking- IS 302-1) |
- |
50 |
|
5% Discount for BIS |
| 7.1(Marking- IS 302-1) |
- |
50 |
|
5% Discount for BIS |
| 7.1(Marking- IS 302-1) |
- |
50 |
|
5% Discount for BIS |
| 7.1(Marking- IS 302-1) |
- |
50 |
|
5% Discount for BIS |
| 7.1(Marking- IS 302-1) |
- |
50 |
|
5% Discount for BIS |
| 7.3(Marking- IS 302-1) |
- |
50 |
|
5% Discount for BIS |
| 7.4(Marking- IS 302-1) |
- |
50 |
|
5% Discount for BIS |
| 7.6(Marking- IS 302-1) |
- |
50 |
|
5% Discount for BIS |
| 7.11(Marking- IS 302-1) |
- |
50 |
|
5% Discount for BIS |
| 7.12(Marking- IS 302-1) |
- |
50 |
|
5% Discount for BIS |
| 7.13(Marking- IS 302-1) |
- |
50 |
|
5% Discount for BIS |
| 7.14(Marking- IS 302-1) |
- |
50 |
|
5% Discount for BIS |
| 7.15(Marking- IS 302-1) |
- |
50 |
|
5% Discount for BIS |
| 7.101(Marking) |
- |
50 |
|
5% Discount for BIS |
| 8( Protection Against Electric Shock, IS 302-1) |
- |
400 |
|
5% Discount for BIS |
| 10(Power Input and Current, IS 302-1) |
- |
800 |
|
5% Discount for BIS |
| 11(Heating, IS 302-1) |
- |
100 |
|
5% Discount for BIS |
| 11(Heating, IS 302-1) |
- |
200 |
|
5% Discount for BIS |
| 11(Heating, IS 302-1) |
- |
100 |
|
5% Discount for BIS |
| 11(Heating, IS 302-1) |
- |
100 |
|
5% Discount for BIS |
| 11(Heating, IS 302-1) |
- |
100 |
|
5% Discount for BIS |
| 11(Heating, IS 302-1) |
- |
100 |
|
5% Discount for BIS |
| 11(Heating, IS 302-1) |
- |
100 |
|
5% Discount for BIS |
| 12(Operation under overload conditions of appliances with heating elements, IS 302-2-202: 1992) |
- |
100 |
|
5% Discount for BIS |
| 13(Electrical Insulation and Leakage Current at Operating Temperature: Leakage current, IS 302-1) |
- |
250 |
|
5% Discount for BIS |
| 13(Electrical Insulation and Leakage Current at Operating Temperature: High Voltage, IS 302-1) |
- |
250 |
|
5% Discount for BIS |
| 15.1(Moisture Resistance, IS 302-1) |
- |
500 |
|
5% Discount for BIS |
| 15.3(Moisture Resistance, IS 302-1) |
- |
500 |
|
5% Discount for BIS |
| 16(Electrical Insulation and Leakage Current at Operating Temperature: Leakage current, IS 302-1) |
- |
250 |
|
5% Discount for BIS |
| 16(Electrical Insulation and Leakage Current at Operating Temperature: High Voltage, IS 302-1) |
- |
250 |
|
5% Discount for BIS |
| 19.2(Abnormal Operation, IS 302-1) |
- |
250 |
|
5% Discount for BIS |
| 19.2(Abnormal Operation, IS 302-1) |
- |
250 |
|
5% Discount for BIS |
| 19.3(Abnormal Operation, IS 302-1) |
- |
250 |
|
5% Discount for BIS |
| 19.3(Abnormal Operation, IS 302-1) |
- |
250 |
|
5% Discount for BIS |
| 20.1(Stability & Mechanical Hazards, IS 302-1) |
- |
500 |
|
5% Discount for BIS |
| 21.1(Mechanical Strength, IS 302-1 & IS 302-2-202) |
- |
500 |
|
5% Discount for BIS |
| 22(Construction, IS 302-1) |
- |
100 |
|
5% Discount for BIS |
| 22.101(Construction) |
- |
100 |
|
5% Discount for BIS |
| 22.102(Construction) |
- |
100 |
|
5% Discount for BIS |
| 22.103(Construction) |
- |
100 |
|
5% Discount for BIS |
| 22.104(Construction) |
- |
100 |
|
5% Discount for BIS |
| 22.105(Construction) |
- |
100 |
|
5% Discount for BIS |
| 22.105.1(Construction) |
- |
100 |
|
5% Discount for BIS |
| 22.105.2(Construction) |
- |
100 |
|
5% Discount for BIS |
| 22.106(Construction) |
- |
100 |
|
5% Discount for BIS |
| 11.107.1(Construction) |
- |
100 |
|
5% Discount for BIS |
| 23.1(Internal Wiring, IS 302-1) |
- |
100 |
|
5% Discount for BIS |
| 23.2(Internal Wiring, IS 302-1) |
- |
100 |
|
5% Discount for BIS |
| 23.8(Internal Wiring, IS 302-1) |
- |
100 |
|
5% Discount for BIS |
| 23.9(Internal Wiring, IS 302-1) |
- |
100 |
|
5% Discount for BIS |
| 23.10(Internal Wiring, IS 302-1) |
- |
100 |
|
5% Discount for BIS |
| 24.1(Components, IS 302-1) |
- |
100 |
|
5% Discount for BIS |
| 24.2(Components, IS 302-1) |
- |
100 |
|
5% Discount for BIS |
| 24.101(Components) |
- |
100 |
|
5% Discount for BIS |
| 22.107(Construction) |
- |
100 |
|
5% Discount for BIS |
| 25.1(Supply Connection and External Flexible Cords, IS 302-1) |
- |
50 |
|
5% Discount for BIS |
| 25.4(Supply Connection and External Flexible Cords) |
- |
50 |
|
5% Discount for BIS |
| 25.5(Supply Connection and External Flexible Cords, IS 302-1) |
- |
50 |
|
5% Discount for BIS |
| 25.6(Supply Connection and External Flexible Cords, IS 302-1) |
- |
50 |
|
5% Discount for BIS |
| 25.8(Supply Connection and External Flexible Cords, IS 302-1) |
- |
50 |
|
5% Discount for BIS |
| 26.9(Supply Connection and External Flexible Cords, IS 302-1) |
- |
50 |
|
5% Discount for BIS |
| 25.1(Supply Connection and External Flexible Cords, IS 302-1) |
- |
50 |
|
5% Discount for BIS |
| 25.11(Supply Connection and External Flexible Cords, IS 302-1) |
- |
50 |
|
5% Discount for BIS |
| 25.12(Supply Connection and External Flexible Cords, IS 302-1) |
- |
50 |
|
5% Discount for BIS |
| 25.15(Supply Connection and External Flexible Cords, IS 302-1) |
- |
50 |
|
5% Discount for BIS |
| 25.16(Supply Connection and External Flexible Cords, IS 302-1) |
- |
50 |
|
5% Discount for BIS |
| 25.17(Supply Connection and External Flexible Cords, IS 302-1) |
- |
50 |
|
5% Discount for BIS |
| 25.18(Supply Connection and External Flexible Cords, IS 302-1) |
- |
50 |
|
5% Discount for BIS |
| 25.19(Supply Connection and External Flexible Cords, IS 302-1) |
- |
50 |
|
5% Discount for BIS |
| 25.2(Supply Connection and External Flexible Cords, IS 302-1) |
- |
50 |
|
5% Discount for BIS |
| 25.21(Supply Connection and External Flexible Cords, IS 302-1) |
- |
50 |
|
5% Discount for BIS |
| 25.22(Supply Connection and External Flexible Cords, IS 302-1) |
- |
50 |
|
5% Discount for BIS |
| 26(Terminals for External Conductors, IS 302-1) |
- |
500 |
|
5% Discount for BIS |
| 27.1(Provision for Earthing, IS 302-1) |
- |
100 |
|
5% Discount for BIS |
| 27.2(Provision for Earthing, IS 302-1) |
- |
100 |
|
5% Discount for BIS |
| 27.3(Provision for Earthing, IS 302-1) |
- |
100 |
|
5% Discount for BIS |
| 27.4(Provision for Earthing, IS 302-1) |
- |
100 |
|
5% Discount for BIS |
| 27.5(Provision for Earthing, IS 302-1) |
- |
100 |
|
5% Discount for BIS |
| 28(Screws & Connections, IS 302-1) |
- |
500 |
|
5% Discount for BIS |
| 29.1(Clearances, Creepage distances and Solid Insulation, IS 302-1) |
- |
250 |
|
5% Discount for BIS |
| 29.2(Clearances, Creepage distances and Solid Insulation, IS 302-1) |
- |
250 |
|
5% Discount for BIS |
| 30.1(Resistance to Heat, Fire & Tracking, IS 302-1) |
- |
500 |
|
5% Discount for BIS |
| 30.2(Resistance to Heat, Fire & Tracking, IS 302-1) |
- |
500 |
|
5% Discount for BIS |
| 31(Resistance of Rusting, IS 302-1) |
- |
500 |
|
5% Discount for BIS |
| 6(Classification- IS 302-1 ) |
- |
50 |
|
5% Discount for BIS |
| 6(Classification- IS 302-1) |
- |
50 |
|
5% Discount for BIS |
| 7.1(Marking- IS 302-1) |
- |
50 |
|
5% Discount for BIS |
| 7.1(Marking- IS 302-1) |
- |
50 |
|
5% Discount for BIS |
| 7.1(Marking- IS 302-1) |
- |
50 |
|
5% Discount for BIS |
| 7.1(Marking- IS 302-1) |
- |
50 |
|
5% Discount for BIS |
| 7.1(Marking- IS 302-1) |
- |
50 |
|
5% Discount for BIS |
| 7.1(Marking- IS 302-1) |
- |
50 |
|
5% Discount for BIS |
| 7.1(Marking- IS 302-1) |
- |
50 |
|
5% Discount for BIS |
| 7.1(Marking- IS 302-1) |
- |
50 |
|
5% Discount for BIS |
| 7.1(Marking- IS 302-1) |
- |
50 |
|
5% Discount for BIS |
| 7.3(Marking- IS 302-1) |
- |
50 |
|
5% Discount for BIS |
| 7.4(Marking- IS 302-1) |
- |
50 |
|
5% Discount for BIS |
| 7.6(Marking- IS 302-1) |
- |
50 |
|
5% Discount for BIS |
| 7.11(Marking- IS 302-1) |
- |
50 |
|
5% Discount for BIS |
| 7.12(Marking- IS 302-1) |
- |
50 |
|
5% Discount for BIS |
| 7.13(Marking- IS 302-1) |
- |
50 |
|
5% Discount for BIS |
| 7.14(Marking- IS 302-1) |
- |
50 |
|
5% Discount for BIS |
| 7.15(Marking- IS 302-1) |
- |
50 |
|
5% Discount for BIS |
| 7.101(Marking) |
- |
50 |
|
5% Discount for BIS |
| 8( Protection Against Electric Shock, IS 302-1) |
- |
400 |
|
5% Discount for BIS |
| 10(Power Input and Current, IS 302-1) |
- |
800 |
|
5% Discount for BIS |
| 11(Heating, IS 302-1) |
- |
200 |
|
5% Discount for BIS |
| 11(Heating, IS 302-1) |
- |
100 |
|
5% Discount for BIS |
| 11(Heating, IS 302-1) |
- |
100 |
|
5% Discount for BIS |
| 11(Heating, IS 302-1) |
- |
100 |
|
5% Discount for BIS |
| 11(Heating, IS 302-1) |
- |
100 |
|
5% Discount for BIS |
| 11(Heating, IS 302-1) |
- |
100 |
|
5% Discount for BIS |
| 11(Heating, IS 302-1) |
- |
100 |
|
5% Discount for BIS |
| 12(Operation under overload conditions of appliances with heating elements, IS 302-2-202: 1992) |
- |
100 |
|
5% Discount for BIS |
| 13(Electrical Insulation and Leakage Current at Operating Temperature: Leakage current, IS 302-1) |
- |
250 |
|
5% Discount for BIS |
| 13(Electrical Insulation and Leakage Current at Operating Temperature: High Voltage, IS 302-1) |
- |
250 |
|
5% Discount for BIS |
| 15.1(Moisture Resistance, IS 302-1) |
- |
1000 |
|
5% Discount for BIS |
| 15.3(Moisture Resistance, IS 302-1) |
- |
1000 |
|
5% Discount for BIS |
| 16(Electrical Insulation and Leakage Current at Operating Temperature: Leakage current, IS 302-1) |
- |
250 |
|
5% Discount for BIS |
| 16(Electrical Insulation and Leakage Current at Operating Temperature: High Voltage, IS 302-1) |
- |
250 |
|
5% Discount for BIS |
| 19.2(Abnormal Operation, IS 302-1) |
- |
250 |
|
5% Discount for BIS |
| 19.2(Abnormal Operation, IS 302-1) |
- |
250 |
|
5% Discount for BIS |
| 19.3(Abnormal Operation, IS 302-1) |
- |
250 |
|
5% Discount for BIS |
| 19.3(Abnormal Operation, IS 302-1) |
- |
250 |
|
5% Discount for BIS |
| 20.1(Stability & Mechanical Hazards, IS 302-1) |
- |
500 |
|
5% Discount for BIS |
| 21.1(Mechanical Strength, IS 302-1 & IS 302-2-202) |
- |
500 |
|
5% Discount for BIS |
| 22(Construction, IS 302-1) |
- |
100 |
|
5% Discount for BIS |
| 22.101(Construction) |
- |
100 |
|
5% Discount for BIS |
| 22.102(Construction) |
- |
100 |
|
5% Discount for BIS |
| 22.103(Construction) |
- |
100 |
|
5% Discount for BIS |
| 22.104(Construction) |
- |
100 |
|
5% Discount for BIS |
| 22.105(Construction) |
- |
100 |
|
5% Discount for BIS |
| 22.105.1(Construction) |
- |
100 |
|
5% Discount for BIS |
| 22.105.2(Construction) |
- |
100 |
|
5% Discount for BIS |
| 22.106(Construction) |
- |
100 |
|
5% Discount for BIS |
| 11.107.1(Construction) |
- |
100 |
|
5% Discount for BIS |
| 23.1(Internal Wiring, IS 302-1) |
- |
100 |
|
5% Discount for BIS |
| 23.2(Internal Wiring, IS 302-1) |
- |
100 |
|
5% Discount for BIS |
| 23.8(Internal Wiring, IS 302-1) |
- |
100 |
|
5% Discount for BIS |
| 23.9(Internal Wiring, IS 302-1) |
- |
100 |
|
5% Discount for BIS |
| 23.10(Internal Wiring, IS 302-1) |
- |
100 |
|
5% Discount for BIS |
| 24.1(Components, IS 302-1) |
- |
100 |
|
5% Discount for BIS |
| 24.2(Components, IS 302-1) |
- |
100 |
|
5% Discount for BIS |
| 24.101(Components) |
- |
100 |
|
5% Discount for BIS |
| 22.107(Construction) |
- |
100 |
|
5% Discount for BIS |
| 25.1(Supply Connection and External Flexible Cords, IS 302-1) |
- |
50 |
|
5% Discount for BIS |
| 25.4(Supply Connection and External Flexible Cords) |
- |
50 |
|
5% Discount for BIS |
| 25.5(Supply Connection and External Flexible Cords, IS 302-1) |
- |
50 |
|
5% Discount for BIS |
| 25.6(Supply Connection and External Flexible Cords, IS 302-1) |
- |
50 |
|
5% Discount for BIS |
| 25.8(Supply Connection and External Flexible Cords, IS 302-1) |
- |
50 |
|
5% Discount for BIS |
| 26.9(Supply Connection and External Flexible Cords, IS 302-1) |
- |
500 |
|
5% Discount for BIS |
| 25.1(Supply Connection and External Flexible Cords, IS 302-1) |
- |
50 |
|
5% Discount for BIS |
| 25.11(Supply Connection and External Flexible Cords, IS 302-1) |
- |
50 |
|
5% Discount for BIS |
| 25.12(Supply Connection and External Flexible Cords, IS 302-1) |
- |
50 |
|
5% Discount for BIS |
| 25.15(Supply Connection and External Flexible Cords, IS 302-1) |
- |
50 |
|
5% Discount for BIS |
| 25.16(Supply Connection and External Flexible Cords, IS 302-1) |
- |
50 |
|
5% Discount for BIS |
| 25.17(Supply Connection and External Flexible Cords, IS 302-1) |
- |
50 |
|
5% Discount for BIS |
| 25.18(Supply Connection and External Flexible Cords, IS 302-1) |
- |
50 |
|
5% Discount for BIS |
| 25.19(Supply Connection and External Flexible Cords, IS 302-1) |
- |
50 |
|
5% Discount for BIS |
| 25.2(Supply Connection and External Flexible Cords, IS 302-1) |
- |
50 |
|
5% Discount for BIS |
| 25.21(Supply Connection and External Flexible Cords, IS 302-1) |
- |
50 |
|
5% Discount for BIS |
| 25.22(Supply Connection and External Flexible Cords, IS 302-1) |
- |
50 |
|
5% Discount for BIS |
| 26(Terminals for External Conductors, IS 302-1) |
- |
500 |
|
5% Discount for BIS |
| 27.1(Provision for Earthing, IS 302-1) |
- |
100 |
|
5% Discount for BIS |
| 27.2(Provision for Earthing, IS 302-1) |
- |
100 |
|
5% Discount for BIS |
| 27.3(Provision for Earthing, IS 302-1) |
- |
100 |
|
5% Discount for BIS |
| 27.4(Provision for Earthing, IS 302-1) |
- |
100 |
|
5% Discount for BIS |
| 27.5(Provision for Earthing, IS 302-1) |
- |
100 |
|
5% Discount for BIS |
| 28(Screws & Connections, IS 302-1) |
- |
500 |
|
5% Discount for BIS |
| 29.1(Clearances, Creepage distances and Solid Insulation, IS 302-1) |
- |
250 |
|
5% Discount for BIS |
| 29.2(Clearances, Creepage distances and Solid Insulation, IS 302-1) |
- |
250 |
|
5% Discount for BIS |
| 30.1(Resistance to Heat, Fire & Tracking, IS 302-1) |
- |
500 |
|
5% Discount for BIS |
| 30.2(Resistance to Heat, Fire & Tracking, IS 302-1) |
- |
500 |
|
5% Discount for BIS |
| 31(Resistance of Rusting, IS 302-1) |
- |
500 |
|
5% Discount for BIS |
| 6(Classification- IS 302-1 ) |
- |
50 |
|
5% Discount for BIS |
| 6(Classification- IS 302-1) |
- |
50 |
|
5% Discount for BIS |
| 7.1(Marking- IS 302-1) |
- |
50 |
|
5% Discount for BIS |
| 7.1(Marking- IS 302-1) |
- |
50 |
|
5% Discount for BIS |
| 7.1(Marking- IS 302-1) |
- |
50 |
|
5% Discount for BIS |
| 7.1(Marking- IS 302-1) |
- |
50 |
|
5% Discount for BIS |
| 7.1(Marking- IS 302-1) |
- |
50 |
|
5% Discount for BIS |
| 7.1(Marking- IS 302-1) |
- |
50 |
|
5% Discount for BIS |
| 7.1(Marking- IS 302-1) |
- |
50 |
|
5% Discount for BIS |
| 7.1(Marking- IS 302-1) |
- |
50 |
|
5% Discount for BIS |
| 7.1(Marking- IS 302-1) |
- |
50 |
|
5% Discount for BIS |
| 7.3(Marking- IS 302-1) |
- |
50 |
|
5% Discount for BIS |
| 7.4(Marking- IS 302-1) |
- |
50 |
|
5% Discount for BIS |
| 7.6(Marking- IS 302-1) |
- |
50 |
|
5% Discount for BIS |
| 7.11(Marking- IS 302-1) |
- |
50 |
|
5% Discount for BIS |
| 7.12(Marking- IS 302-1) |
- |
50 |
|
5% Discount for BIS |
| 7.13(Marking- IS 302-1) |
- |
50 |
|
5% Discount for BIS |
| 7.14(Marking- IS 302-1) |
- |
50 |
|
5% Discount for BIS |
| 7.15(Marking- IS 302-1) |
- |
50 |
|
5% Discount for BIS |
| 7.101(Marking) |
- |
50 |
|
5% Discount for BIS |
| 8( Protection Against Electric Shock, IS 302-1) |
- |
400 |
|
5% Discount for BIS |
| 10(Power Input and Current, IS 302-1) |
- |
800 |
|
5% Discount for BIS |
| 11(Heating, IS 302-1) |
- |
100 |
|
5% Discount for BIS |
| 11(Heating, IS 302-1) |
- |
100 |
|
5% Discount for BIS |
| 11(Heating, IS 302-1) |
- |
100 |
|
5% Discount for BIS |
| 11(Heating, IS 302-1) |
- |
100 |
|
5% Discount for BIS |
| 11(Heating, IS 302-1) |
- |
100 |
|
5% Discount for BIS |
| 11(Heating, IS 302-1) |
- |
100 |
|
5% Discount for BIS |
| 11(Heating, IS 302-1) |
- |
100 |
|
5% Discount for BIS |
| 12(Operation under overload conditions of appliances with heating elements, IS 302-2-202: 1992) |
- |
100 |
|
5% Discount for BIS |
| 13(Electrical Insulation and Leakage Current at Operating Temperature: Leakage current, IS 302-1) |
- |
250 |
|
5% Discount for BIS |
| 13(Electrical Insulation and Leakage Current at Operating Temperature: High Voltage, IS 302-1) |
- |
250 |
|
5% Discount for BIS |
| 15.1(Moisture Resistance, IS 302-1) |
- |
500 |
|
5% Discount for BIS |
| 15.3(Moisture Resistance, IS 302-1) |
- |
500 |
|
5% Discount for BIS |
| 16(Electrical Insulation and Leakage Current at Operating Temperature: Leakage current, IS 302-1) |
- |
250 |
|
5% Discount for BIS |
| 16(Electrical Insulation and Leakage Current at Operating Temperature: High Voltage, IS 302-1) |
- |
250 |
|
5% Discount for BIS |
| 19.2(Abnormal Operation, IS 302-1) |
- |
250 |
|
5% Discount for BIS |
| 19.2(Abnormal Operation, IS 302-1) |
- |
250 |
|
5% Discount for BIS |
| 19.3(Abnormal Operation, IS 302-1) |
- |
250 |
|
5% Discount for BIS |
| 19.3(Abnormal Operation, IS 302-1) |
- |
250 |
|
5% Discount for BIS |
| 20.1(Stability & Mechanical Hazards, IS 302-1) |
- |
250 |
|
5% Discount for BIS |
| 21.1(Mechanical Strength, IS 302-1 & IS 302-2-202) |
- |
500 |
|
5% Discount for BIS |
| 22(Construction, IS 302-1) |
- |
100 |
|
5% Discount for BIS |
| 22.101(Construction) |
- |
100 |
|
5% Discount for BIS |
| 22.102(Construction) |
- |
100 |
|
5% Discount for BIS |
| 22.103(Construction) |
- |
100 |
|
5% Discount for BIS |
| 22.104(Construction) |
- |
100 |
|
5% Discount for BIS |
| 22.105(Construction) |
- |
100 |
|
5% Discount for BIS |
| 22.105.1(Construction) |
- |
100 |
|
5% Discount for BIS |
| 22.105.2(Construction) |
- |
100 |
|
5% Discount for BIS |
| 22.106(Construction) |
- |
100 |
|
5% Discount for BIS |
| 11.107.1(Construction) |
- |
100 |
|
5% Discount for BIS |
| 23.1(Internal Wiring, IS 302-1) |
- |
100 |
|
5% Discount for BIS |
| 23.2(Internal Wiring, IS 302-1) |
- |
100 |
|
5% Discount for BIS |
| 23.8(Internal Wiring, IS 302-1) |
- |
100 |
|
5% Discount for BIS |
| 23.9(Internal Wiring, IS 302-1) |
- |
100 |
|
5% Discount for BIS |
| 23.10(Internal Wiring, IS 302-1) |
- |
100 |
|
5% Discount for BIS |
| 24.1(Components, IS 302-1) |
- |
100 |
|
5% Discount for BIS |
| 24.2(Components, IS 302-1) |
- |
100 |
|
5% Discount for BIS |
| 24.101(Components) |
- |
100 |
|
5% Discount for BIS |
| 22.107(Construction) |
- |
100 |
|
5% Discount for BIS |
| 25.1(Supply Connection and External Flexible Cords, IS 302-1) |
- |
50 |
|
5% Discount for BIS |
| 25.4(Supply Connection and External Flexible Cords) |
- |
50 |
|
5% Discount for BIS |
| 25.5(Supply Connection and External Flexible Cords, IS 302-1) |
- |
50 |
|
5% Discount for BIS |
| 25.6(Supply Connection and External Flexible Cords, IS 302-1) |
- |
50 |
|
5% Discount for BIS |
| 25.8(Supply Connection and External Flexible Cords, IS 302-1) |
- |
50 |
|
5% Discount for BIS |
| 26.9(Supply Connection and External Flexible Cords, IS 302-1) |
- |
500 |
|
5% Discount for BIS |
| 25.1(Supply Connection and External Flexible Cords, IS 302-1) |
- |
50 |
|
5% Discount for BIS |
| 25.11(Supply Connection and External Flexible Cords, IS 302-1) |
- |
50 |
|
5% Discount for BIS |
| 25.12(Supply Connection and External Flexible Cords, IS 302-1) |
- |
50 |
|
5% Discount for BIS |
| 25.15(Supply Connection and External Flexible Cords, IS 302-1) |
- |
50 |
|
5% Discount for BIS |
| 25.16(Supply Connection and External Flexible Cords, IS 302-1) |
- |
50 |
|
5% Discount for BIS |
| 25.17(Supply Connection and External Flexible Cords, IS 302-1) |
- |
50 |
|
5% Discount for BIS |
| 25.18(Supply Connection and External Flexible Cords, IS 302-1) |
- |
50 |
|
5% Discount for BIS |
| 25.19(Supply Connection and External Flexible Cords, IS 302-1) |
- |
50 |
|
5% Discount for BIS |
| 25.2(Supply Connection and External Flexible Cords, IS 302-1) |
- |
50 |
|
5% Discount for BIS |
| 25.21(Supply Connection and External Flexible Cords, IS 302-1) |
- |
50 |
|
5% Discount for BIS |
| 25.22(Supply Connection and External Flexible Cords, IS 302-1) |
- |
50 |
|
5% Discount for BIS |
| 26(Terminals for External Conductors, IS 302-1) |
- |
50 |
|
5% Discount for BIS |
| 27.1(Provision for Earthing, IS 302-1) |
- |
100 |
|
5% Discount for BIS |
| 27.2(Provision for Earthing, IS 302-1) |
- |
100 |
|
5% Discount for BIS |
| 27.3(Provision for Earthing, IS 302-1) |
- |
100 |
|
5% Discount for BIS |
| 27.4(Provision for Earthing, IS 302-1) |
- |
100 |
|
5% Discount for BIS |
| 27.5(Provision for Earthing, IS 302-1) |
- |
100 |
|
5% Discount for BIS |
| 28(Screws & Connections, IS 302-1) |
- |
500 |
|
5% Discount for BIS |
| 29.1(Clearances, Creepage distances and Solid Insulation, IS 302-1) |
- |
250 |
|
5% Discount for BIS |
| 29.2(Clearances, Creepage distances and Solid Insulation, IS 302-1) |
- |
250 |
|
5% Discount for BIS |
| 30.1(Resistance to Heat, Fire & Tracking, IS 302-1) |
- |
500 |
|
5% Discount for BIS |
| 30.2(Resistance to Heat, Fire & Tracking, IS 302-1) |
- |
500 |
|
5% Discount for BIS |
| 31(Resistance of Rusting, IS 302-1) |
- |
500 |
|
5% Discount for BIS |
|
26 Sep, 2028 |
- Included w.e.f.12.12.2024
Exclusion
Cl 24, CL 22, (EMI/EMC)
19.11.4.1 to 19.11.4.7 |
| 9657 |
IDMA LABORATORIES LIMITED, PANCHKULA
| 9123236
| IS 10631 (1983) |
Specification for stainless steel for welding electrode core wire |
- |
21000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 5.1 Table 1(Carbon- Relevant parts of IS 228 or any other established instrumental /Chemical method) |
- |
2000 |
|
- |
| 5.1 Table 1(Silicon- Relevant parts of IS 228 or any other established instrumental /Chemical method) |
- |
2000 |
|
- |
| 5.1 Table 1(Manganese- Relevant parts of IS 228 or any other established instrumental /Chemical method) |
- |
2000 |
|
- |
| 5.1 Table 1(Chromium- Relevant parts of IS 228 or any other established instrumental /Chemical method) |
- |
2000 |
|
- |
| 5.1 Table 1(Nickel- Relevant parts of IS 228 or any other established instrumental /Chemical method) |
- |
2000 |
|
- |
| 5.1 Table 1(Molybdenum- Relevant parts of IS 228 or any other established instrumental /Chemical method) |
- |
2000 |
|
- |
| 5.1 Table 1(Sulphur- Relevant parts of IS 228 or any other established instrumental /Chemical method) |
- |
2000 |
|
- |
| 5.1 Table 1(Phosphorous- Relevant parts of IS 228 or any other established instrumental /Chemical method) |
- |
2000 |
|
- |
| 6(FREEDOM FROM DEFECTS) |
- |
2000 |
|
- |
| 7(Size and Tolerances) |
- |
3000 |
|
- |
| Clause 5.1(Molybdenum) |
- |
0 |
|
(Repeat entry) |
| Clause 5.1(Nickel) |
- |
0 |
|
(Repeat entry) |
| Clause 5.1(Chromium) |
- |
0 |
|
(Repeat entry) |
| Clause 5.1(Silicon) |
- |
0 |
|
(Repeat entry) |
| Clause 5.1(Phosphorous) |
- |
0 |
|
(Repeat entry) |
| Clause 5.1(Sulphur) |
- |
0 |
|
(Repeat entry) |
| Clause 5.1(Manganese) |
- |
0 |
|
(Repeat entry) |
| Clause 5.1(Carbon) |
- |
0 |
|
(Repeat entry) |
| 5.1 Table 1(Carbon- Relevant parts of IS 228 or any other established instrumental /Chemical method) |
- |
0 |
|
(Repeat entry) |
| 5.1 Table 1(Silicon- Relevant parts of IS 228 or any other established instrumental /Chemical method) |
- |
0 |
|
(Repeat entry) |
| 5.1 Table 1(Manganese- Relevant parts of IS 228 or any other established instrumental /Chemical method) |
- |
0 |
|
(Repeat entry) |
| 5.1 Table 1(Chromium- Relevant parts of IS 228 or any other established instrumental /Chemical method) |
- |
0 |
|
(Repeat entry) |
| 5.1 Table 1(Nickel- Relevant parts of IS 228 or any other established instrumental /Chemical method) |
- |
0 |
|
(Repeat entry) |
| 5.1 Table 1(Molybdenum- Relevant parts of IS 228 or any other established instrumental /Chemical method) |
- |
0 |
|
(Repeat entry) |
| 5.1 Table 1(Sulphur- Relevant parts of IS 228 or any other established instrumental /Chemical method) |
- |
0 |
|
(Repeat entry) |
| 5.1 Table 1(Phosphorous- Relevant parts of IS 228 or any other established instrumental /Chemical method) |
- |
0 |
|
(Repeat entry) |
| 6(FREEDOM FROM DEFECTS) |
- |
0 |
|
(Repeat entry) |
| 7(Size and Tolerances) |
- |
0 |
|
(Repeat entry) |
| Clause 5.1(Molybdenum) |
- |
0 |
|
(Repeat entry) |
| Clause 5.1(Nickel) |
- |
0 |
|
(Repeat entry) |
| Clause 5.1(Chromium) |
- |
0 |
|
(Repeat entry) |
| Clause 5.1(Silicon) |
- |
0 |
|
(Repeat entry) |
| Clause 5.1(Phosphorous) |
- |
0 |
|
(Repeat entry) |
| Clause 5.1(Sulphur) |
- |
0 |
|
(Repeat entry) |
| Clause 5.1(Manganese) |
- |
0 |
|
(Repeat entry) |
| Clause 5.1(Carbon) |
- |
0 |
|
(Repeat entry) |
| 5.1 Table 1(Carbon- Relevant parts of IS 228 or any other established instrumental /Chemical method) |
- |
0 |
|
(Repeat entry) |
| 5.1 Table 1(Silicon- Relevant parts of IS 228 or any other established instrumental /Chemical method) |
- |
0 |
|
(Repeat entry) |
| 5.1 Table 1(Manganese- Relevant parts of IS 228 or any other established instrumental /Chemical method) |
- |
0 |
|
(Repeat entry) |
| 5.1 Table 1(Chromium- Relevant parts of IS 228 or any other established instrumental /Chemical method) |
- |
0 |
|
(Repeat entry) |
| 5.1 Table 1(Nickel- Relevant parts of IS 228 or any other established instrumental /Chemical method) |
- |
0 |
|
(Repeat entry) |
| 5.1 Table 1(Molybdenum- Relevant parts of IS 228 or any other established instrumental /Chemical method) |
- |
0 |
|
(Repeat entry) |
| 5.1 Table 1(Sulphur- Relevant parts of IS 228 or any other established instrumental /Chemical method) |
- |
0 |
|
(Repeat entry) |
| 5.1 Table 1(Phosphorous- Relevant parts of IS 228 or any other established instrumental /Chemical method) |
- |
0 |
|
(Repeat entry) |
| 6(FREEDOM FROM DEFECTS) |
- |
0 |
|
(Repeat entry) |
| 7(Size and Tolerances) |
- |
0 |
|
(Repeat entry) |
| Clause 5.1(Molybdenum) |
- |
0 |
|
(Repeat entry) |
| Clause 5.1(Nickel) |
- |
0 |
|
(Repeat entry) |
| Clause 5.1(Chromium) |
- |
0 |
|
(Repeat entry) |
| Clause 5.1(Silicon) |
- |
0 |
|
(Repeat entry) |
| Clause 5.1(Phosphorous) |
- |
0 |
|
(Repeat entry) |
| Clause 5.1(Sulphur) |
- |
0 |
|
(Repeat entry) |
| Clause 5.1(Manganese) |
- |
0 |
|
(Repeat entry) |
| Clause 5.1(Carbon) |
- |
0 |
|
(Repeat entry) |
|
31 Dec, 2029 |
- Included w.e.f.21.11.2024 |
| 9658 |
International Testing Centre, MSME Technology Development Centre, Meerut
| 8177804
| IS 17012 (2018) |
High ankle tactical boots with pu - Rubber sole - Specification |
- |
38600 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 5.0(Innocuousness Test IS 17011) |
- |
20000 |
|
- |
| 4.16.2(Breaking Strength of lace ) |
- |
500 |
|
- |
| 4.16.1(Length of lace ) |
- |
300 |
|
- |
| 4.15(D-ring & Hooks ) |
- |
300 |
|
- |
| 6.1(Resistance to Fuel Oil) |
- |
500 |
|
- |
| 4.14.9(Resistance to hot contact ) |
- |
500 |
|
- |
| 4.14.8(Flexing resistance ) |
- |
800 |
|
- |
| 4.14.7(Ageing test) |
- |
1500 |
|
- |
| 4.14.6(Hardness (IRHD)) |
- |
500 |
|
- |
| 4.14.5(Abrasion resistance ) |
- |
800 |
|
- |
| 4.14.4(Tear Strength) |
- |
500 |
|
- |
| 4.14.3(Sole Density ) |
- |
300 |
|
- |
| 4.14.2(Thickness) |
- |
300 |
|
- |
| 4.14.1(Material) |
- |
500 |
|
- |
| 4.13(Breaking Strength of thread ) |
- |
500 |
|
- |
| 4.12.2(Tear Strength) |
- |
500 |
|
- |
| 4.12.1(Thickness ) |
- |
300 |
|
- |
| 4.11.2(Tear Strength) |
- |
500 |
|
- |
| 4.11.1(Thickness ) |
- |
300 |
|
- |
| 4.10.3(Water absorption & desorption percent) |
- |
1000 |
|
- |
| 4.10.2(Abrasion resistance ) |
- |
1000 |
|
- |
| 4.10.1(Material) |
- |
500 |
|
- |
| 4.9.3(Water absorption & desorption percent) |
- |
1000 |
|
- |
| 4.9.2(Abrasion resistance ) |
- |
1000 |
|
- |
| 4.9.1(Thickness) |
- |
300 |
|
- |
| 4.8(Thickness Toe puff & counter stiffener) |
- |
1000 |
|
- |
| 4.7.5(Water Vapour permeability & coefficient ) |
- |
1000 |
|
- |
| 4.7.4(Abrasion resistance ) |
- |
800 |
|
- |
| 4.7.3(Tear Strength) |
- |
500 |
|
- |
| 4.7.2(Material Counter & Tongue) |
- |
800 |
|
- |
| 4.7.1(Material vamp & Quarter) |
- |
800 |
|
- |
| 4.6.3(Water Penetration and water absorption ) |
- |
1000 |
|
- |
| 4.6.2(Tear Strength) |
- |
500 |
|
- |
| 4.6.1(Thickness ) |
- |
300 |
|
- |
| 4.5.8(Energy absorption of seat region ) |
- |
500 |
|
- |
| 4.5.7(Cold Insulation of sole complex) |
- |
500 |
|
- |
| 4.5.6(Heat Insulation of sole Complex) |
- |
500 |
|
- |
| 4.5.5(Antistatic test) |
- |
1000 |
|
- |
| 4.5.4(Slip Resitance) |
- |
1500 |
|
- |
| 4.5.3.2(Interayer bond strength) |
- |
500 |
|
- |
| 4.5.3.1(Upper/outsole bond strength) |
- |
500 |
|
- |
| 4.5.2(Ergonomic Feature) |
- |
500 |
|
- |
| 4.5.1(Construction) |
- |
500 |
|
- |
| 4.4(Height of upper ) |
- |
300 |
|
- |
| 4.3.2(Weight) |
- |
300 |
|
- |
| 4.2(Design ) |
- |
300 |
|
- |
| Cl. 6, Cl.6.1, 6.1.1 & 6.1.2, 8.6 of IS 15298 part 1,ISO 1817,ISO 4643,(Resistance to fuel oil) |
- |
1500 |
|
- |
| 8, 8.1, 8.2, 8.2.1(Marking) |
- |
300 |
|
- |
| 9(Information to be Supplied) |
- |
300 |
|
- |
| Cl.4.6.4(Water Penetration and Water Absorption) |
- |
1000 |
|
- |
| Cl. 6, Cl.6.1, 6.1.1 & 6.1.2,(Resistance to fuel oil) |
- |
500 |
|
- |
| CL.8,8.1, 8.2,8.2.1(Marking) |
- |
300 |
|
- |
| Cl.9,(Information to be Supplied) |
- |
300 |
|
- |
| 4.3.1(Size) |
- |
300 |
|
- |
|
15 Apr, 2027 |
- Included w.e.f 19.09.2024 |
| 9659 |
Ahmedabad Textile Industry's Research Association (ATIRA), Ahmedabad
| 7173002
| IS 16089 (2013) |
Jute agro-textile – Sapling bags for growth of seedling/ sapling – Specification |
- |
3250 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Clause 4, Table 1, (i)(Mass, g/m², Min) |
- |
450 |
|
- |
| Clause 4, Table 1, (ii)(Thickness, mm) |
- |
450 |
|
- |
| Clause 4, Table 1, (iv) a(Threads/dm, Warp) |
- |
150 |
|
- |
| Clause 4, Table 1, (iv) b(Threads/dm, Weft) |
- |
150 |
|
- |
| Clause 4, Table 1, (v)(Width of Hessian fabric, cm) |
- |
200 |
|
- |
| Clause 4, Table 1, (vi)(Length and width of sapling bags, cm, Min) |
- |
400 |
|
- |
| Clause 4, Table 1, (vii)(Water holding capacity, percent) |
- |
550 |
|
- |
| Clause 4, Table 1, (viii) a(Tensile strength, kN/m, Warp) |
- |
450 |
|
- |
| Clause 4, Table 1, (viii) b(Tensile strength, kN/m, Weft) |
- |
450 |
|
- |
|
- |
- Included w.e.f 10.10.2024
Excluding Cl 4, Table 1, (iii) (Open area, percent) |
| 9660 |
Alpha Test House Services LLP (160), Sahibzada Ajit Singh Nagar
| 9138706
| IS 2501 (1995) |
Solid drawn copper tubesfor general engineering purposes - Specification (Third Revision) |
Copper tubes |
15000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl. No.5(Grades) |
- |
6000 |
|
Hydrogen Embrittlement Test. 5000/- extra charges. |
| Cl. No.6(CONDITION) |
- |
100 |
|
Hydrogen Embrittlement Test. 5000/- extra charges. |
| Cl. No. 7(FREEDOM FROM DEFECTS) |
- |
100 |
|
Hydrogen Embrittlement Test. 5000/- extra charges. |
| Cl. No. 8.1(Dimensions) |
- |
1500 |
|
Hydrogen Embrittlement Test. 5000/- extra charges. |
| Cl. No. 8.2(Tolerances) |
- |
200 |
|
Hydrogen Embrittlement Test. 5000/- extra charges. |
| Cl. No. 9(CHEMICAL COMPOSITION) |
- |
6000 |
|
Hydrogen Embrittlement Test. 5000/- extra charges. |
| Cl. No. 10.1.1, Table no. 1(Tensile Test) |
- |
2500 |
|
Hydrogen Embrittlement Test. 5000/- extra charges. |
| Cl. No. 10.2(Flattening and Doubling-Over Test) |
- |
1900 |
|
Hydrogen Embrittlement Test. 5000/- extra charges. |
| Cl. No. 10.3(Drift Expanding Test) |
- |
2000 |
|
Hydrogen Embrittlement Test. 5000/- extra charges. |
| Cl. No. 10.4(Non-Destructive Testing) |
- |
100 |
|
Hydrogen Embrittlement Test. 5000/- extra charges. |
| Cl. No. 10.5("Microscopic Examination ( for 0 Condition
Only )") |
- |
500 |
|
Hydrogen Embrittlement Test. 5000/- extra charges. |
| Cl. No. 13(Marking) |
- |
100 |
|
Hydrogen Embrittlement Test. 5000/- extra charges. |
| 10.6(Hydrogen Embrittlement Test) |
- |
0 |
|
Hydrogen Embrittlement Test. 5000/- extra charges. |
| Cl. No.5(Grades) |
- |
6000 |
|
- |
| Cl. No.6(CONDITION) |
- |
100 |
|
- |
| Cl. No. 7(FREEDOM FROM DEFECTS) |
- |
100 |
|
- |
| Cl. No. 8.1(Dimensions) |
- |
1500 |
|
- |
| Cl. No. 8.2(Tolerances) |
- |
200 |
|
- |
| Cl. No. 9(CHEMICAL COMPOSITION) |
- |
6000 |
|
- |
| Cl. No. 10.1.1, Table no. 1(Tensile Test) |
- |
2500 |
|
- |
| Cl. No. 10.2(Flattening and Doubling-Over Test) |
- |
1900 |
|
- |
| Cl. No. 10.3(Drift Expanding Test) |
- |
2000 |
|
- |
| Cl. No. 10.4(Non-Destructive Testing) |
- |
100 |
|
- |
| Cl. No. 10.5("Microscopic Examination ( for 0 Condition
Only )") |
- |
500 |
|
- |
| Cl. No. 13(Marking) |
- |
100 |
|
- |
| 10.6(Hydrogen Embrittlement Test) |
- |
0 |
|
- |
|
31 Dec, 2029 |
- Included w.e.f. 15.04.2024 |