10621 |
BIS Patna Branch Laboratory (PBL)
| IS 3589 (2001) |
Steel pipes for water and sewage (168.3 To 2540 Mm Outside Diameter) - Specification (Third Revision) |
- |
- View breakup
Rs. 11800/- (for SAW Pipe ) Rs. 10380/- for (ERW Fe410 , Fe450 &Fe330)
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
8.1 Table 2 Table 3 (Carbon Content IS 228) |
- |
|
|
|
8.1 Table 2 Table 3 (Manganese Content IS 228) |
- |
|
|
|
8.1 Table 2 Table 3 (Phosphorus Content IS 228) |
- |
|
|
|
8.1 Table 2 Table 3 (Sulphur Content IS 228) |
- |
|
|
|
11.1, Table 5. (Outside Diameter (OD)) |
- |
|
|
|
11.1, Table 5. (Thickness) |
- |
|
|
|
11.1, Table 5. (Mass) |
- |
|
|
|
12.3.3 (Ovality) |
- |
|
|
|
12.5 (Strightness) |
- |
|
|
|
14.1 (Visual inspection, Appearance and Workmanship) |
- |
|
|
|
14.2 (Visual inspection, Appearance and Workmanship) |
- |
|
|
|
14.3 (Visual inspection, Appearance and Workmanship) |
- |
|
|
|
14.4 (Visual inspection, Appearance and Workmanship-Dent Depth(below 610 mm OD)) |
- |
|
|
|
14.4 (Visual inspection, Appearance and Workmanship-Dent Depth(Above 610 mm OD)) |
- |
|
|
|
14.4 (Visual inspection, Appearance and Workmanship-Dent Length) |
- |
|
|
|
14.4 (Visual inspection, Appearance and Workmanship-Dent Length) |
- |
|
|
|
9.1 (Tensile test-Yield Strength) |
- |
|
|
|
9.1 (Tensile test-Strength) |
- |
|
|
|
9.1 (Tensile test- Elongation) |
- |
|
|
|
9.3 (Guided Bend Test
(for SAW Pipes)) |
- |
|
|
|
9.2.3 (Flattening Test for
seamless pipes) |
- |
|
|
|
9.2.1 (Flattening test for
ERW pipes ) |
- |
|
|
|
|
- |
- All test facilities are available as per the IS except-
i. Hydraulic Pressure Test (Clause 10) [This test is to be carried out at the manufacturers' end only.]
ii. Tests for micro alloying elements and Aluminium (Clause 8.2)
iii. Ovality Test Facility is not available for size 273 mm and above (Clause 12.3.3) |
10622 |
BIS Patna Branch Laboratory (PBL)
| IS 299 (2012) |
Alumino - Ferric - Specification (Fifth Revision) |
- |
- View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
1 (i) Table 1 ( Insouble matter, Grade 1, A-3) |
- |
|
|
|
1 (ii) Table 1 (Soluble iron compound (as Fe2+ and Fe3+), Grade 1, A-4) |
- |
|
|
|
1 (iii) Table 1 (Water soluble aluminium compounds (as Al2O3), Grade 1, A-5) |
- |
|
|
|
1 (iv) Table 1 (pH (of 5 percent aqueous solution), Grade 1, A-6) |
- |
|
|
|
1 (v) Table 1 (Free acidity (as H2SO4)/Basicity (as Al2O3), Grade 1, A-7) |
- |
|
|
|
1 (i) Table 1 ( Insouble matter, Grade 2, A-3) |
- |
|
|
|
1 (i) Table 1 ( Insouble matter, Grade 3, A-3) |
- |
|
|
|
1 (i) Table 1 ( Insouble matter, Grade 4, A-3) |
- |
|
|
|
1 (i) Table 1 ( Insouble matter, Grade 5, A-3) |
- |
|
|
|
1 (ii) Table 1 (Soluble iron compound (as Fe2+ and Fe3+), Grade 2, A-4) |
- |
|
|
|
1 (ii) Table 1 (Soluble iron compound (as Fe2+ and Fe3+), Grade 3, A-4) |
- |
|
|
|
1 (ii) Table 1 (Soluble iron compound (as Fe2+ and Fe3+), Grade 4, A-4) |
- |
|
|
|
1 (ii) Table 1 (Soluble iron compound as Fe2+ and Fe3+), Grade 5, A-4) |
- |
|
|
|
1 (iii) Table 1 (Water soluble aluminium compounds (as Al2O3), Grade 2, A-5) |
- |
|
|
|
1 (iii) Table 1 (Water soluble aluminium compounds (as Al2O3), Grade 3, A-5) |
- |
|
|
|
1 (iii) Table 1 (Water soluble aluminium compounds (as Al2O3), Grade 4, A-5) |
- |
|
|
|
1 (iii) Table 1 (Water soluble aluminium compounds (as Al2O3), Grade 5, A-5) |
- |
|
|
|
1 (iv) Table 1 (pH (of 5 percent aqueous solution), Grade 2, A-6) |
- |
|
|
|
1 (iv) Table 1 (pH (of 5 percent aqueous solution), Grade 3, A-6) |
- |
|
|
|
1 (iv) Table 1 (pH (of 5 percent aqueous solution), Grade 4, A-6) |
- |
|
|
|
1 (iv) Table 1 (pH (of 5 percent aqueous solution), Grade 5, A-6) |
- |
|
|
|
1 (v) Table 1 (Free acidity (as H2SO4)/Basicity (as Al2O3), Grade 2, A-7) |
- |
|
|
|
1 (v) Table 1 (Free acidity (as H2SO4)/Basicity (as Al2O3), Grade 3, A-7) |
- |
|
|
|
1 (v) Table 1 (Free acidity (as H2SO4)/Basicity (as Al2O3), Grade 4, A-7) |
- |
|
|
|
1 (v) Table 1 (Free acidity (as H2SO4)/Basicity (as Al2O3), Grade 5, A-7) |
- |
|
|
|
|
- |
- - |
10623 |
BIS Patna Branch Laboratory (PBL)
| IS 2879 (1998) |
Mild steel for metal arc welding electrodes - Specification (Third Revision) |
- |
Testing charges are Rs.9050/- View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
Cl 7 (Workmanship) |
- |
|
|
|
Cl 8 & 9 (Diameter) |
- |
|
|
|
6 (Carbon %) |
- |
|
|
|
6 (Manganese %) |
- |
|
|
|
6 (Phosphorus %) |
- |
|
|
|
6 (Sulphur %) |
- |
|
|
|
6 (Silicon %) |
- |
|
|
|
Cl. 9.2 (Maximum Difference between 2 readings taken at any 2 diameters across cross section) |
- |
|
|
|
Cl. 8,9 (Width across flat) |
- |
|
|
|
Cl. 8,9 (Length) |
- |
|
|
|
|
- |
- All test facilities are available as per the IS except tests for Copper, Vanadium, Nickel, Titanium, Chromium and Almunium (Clause 6) |
10624 |
BIS Patna Branch Laboratory (PBL)
| IS 280 (2006) |
Mild steel wire for general engineering purposes (Fourth Revision) |
- |
Rs.3750.00 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
Cl 7 & Table 1 (Diameter & Difference Between Two Reading On Any Two Diameters) |
- |
|
|
|
Cl 9 (Tensile Test On UTM) |
- |
|
|
|
Cl 11 (Workmanship) |
- |
|
|
|
Cl 13 (Workmanship) |
- |
|
|
|
6 AND AS PER IS 7887 (PHOSPHORUS) |
- |
|
|
|
6 AND AS PER IS 7887 (SULPHUR) |
- |
|
|
|
6 AND AS PER IS 7887 (MANGANESE) |
- |
|
|
|
6 AND AS PER IS 7887 (SILICON) |
- |
|
|
|
6 AND AS PER IS 7887 (CARBON) |
- |
|
|
|
9.2 (Wrapping Test) |
- |
|
|
|
9.3 (Bend test) |
- |
|
|
|
10 (Finish) |
- |
|
|
|
11 (Coating test) |
- |
|
|
|
13 (Freedom from defects) |
- |
|
|
|
11 (Coating test) |
- |
|
|
|
|
- |
- All test facilities are available as per the IS except tests for Aluminium and Copper (Clause 6) |
10625 |
BIS Patna Branch Laboratory (PBL)
| IS 253 (2014) |
Specification for common salt (Fourth Revision) |
- |
- View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
Clause -3 for common salt 3.1 ( 3.1.1 ) ( The material shall be crystalline solid, white or pale pink or light grey in colour.) |
- |
|
|
|
Clause -3 for common salt 3.1 ( 3.1.2 ) Annex-2 (Moisture The material shall contain not more than 6.0 percent by mass of moisture, on as received basis, when tested according to the method given in A-2) |
- |
|
|
|
Clause-3.2 for dairy salt (3.2.1) (The material shall be crystalline white solid and free from any visible impurities.) |
- |
|
|
|
Clause-3.1 for dairy salt (3.2.2) (3.2.2 Particle Size 99 percent by mass of the material shall pass completely through 850-micron IS Sieve [see IS 460 (Part I)].) |
- |
|
|
|
Clause-3.2 for dairy salt (3.2.3) Annex -2 (3.2.3 Moisture The material shall contain not more than 0.5 percent by mass of moisture, on as received basis, when tested according to the methods given in A-2.) |
- |
|
|
|
Table 1 (i) Annex -4 (Water insoluble matter, common) |
- |
|
|
|
Table 1 (i) Annex -4 (Water insoluble matter, Dairy) |
- |
|
|
|
Table 1 (ii) Annex-5 (Chloride content (as NaCl)common) |
- |
|
|
|
Table 1 (ii) Annex-5 (Chloride content (as NaCl), Dairy) |
- |
|
|
|
Table 1 (iii) Annex-6 ( Matter soluble in water, other than sodium chloride, common) |
- |
|
|
|
Table 1 (iii) Annex-6 ( Matter soluble in water, other than sodium chloride, Dairy) |
- |
|
|
|
Table 1 (iv) (Calcium (as Ca), water soluble, percent by mass, common) |
- |
|
|
|
Table 1 (iv) Annex-7 (Calcium (as Ca), water soluble, percent by mass, Dairy) |
- |
|
|
|
Table 1 (v) (Magnesium (as Mg), water soluble, percent by mass, common ) |
- |
|
|
|
Table 1 (v) Annex-7 (Magnesium (as Mg), water soluble, percent by mass, Dairy ) |
- |
|
|
|
Table 1 (vi) (Sulphate as SO2 percent by mass, common) |
- |
|
|
|
Table 1 (vi) Annex-8 (sulphate as SO2 percent by mass, Dairy) |
- |
|
|
|
Table 1 (vii) Annex-9 (Alkalinity (as Na2CO3), common) |
- |
|
|
|
Table 1 (vii) Annex-11 (Alkalinity (as Na2CO3), Dairy) |
- |
|
|
|
Table 1 (ix) (Iron (as Fe), common) |
- |
|
|
|
Table 1 (ix) (Iron (as Fe), Dairy) |
- |
|
|
|
Table 1 (xi) Annex-12 (Copper (as Cu), common) |
- |
|
|
|
Table 1 (xi) Annex-12 (Copper (as Cu), Dairy ) |
- |
|
|
|
Table 1 (x) Annex-11 (x) Arsenic (as As), common) |
- |
|
|
|
Table 1 (x) Annex-11 (x) Arsenic (as As),Dairy) |
- |
|
|
|
|
- |
- All test facilities are available as per the IS except tests for Lead (Clause 3.1.4) |
10626 |
BIS Patna Branch Laboratory (PBL)
| IS 2124 (2000) |
Sodium bicarbonate - Specification (Second Revision) |
- |
Rs 4660/- for Pure Grade View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
3.1 (Grade) |
- |
|
|
|
4.1 (Description) |
- |
|
|
|
4.2 (Table 1 S.no.(i)) (Total Alkalinity (as NaHCO3)) |
- |
|
|
|
4.2 (Table 1 S.no.(i)) (pH ) |
- |
|
|
|
4.2 (Table 1 S.no.(ii)) (Chlorides (as Cl)) |
- |
|
|
|
4.2 (Table 1 S.no.(iii)) (Insoluble matter) |
- |
|
|
|
4.2 (Table 1 S.no.(iv)) (Sulphates (as SO4)) |
- |
|
|
|
|
- |
- All test facilities are available as per the IS |
10627 |
BIS Patna Branch Laboratory (PBL)
| IS 1507 (1977) |
Specification for copper oxychloride water dispersible powder concentrates |
- |
Rs 2700/- View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
Cl.2.1 (Description) |
- |
|
|
|
Cl. 2.3, Table-1 (pH of one percent aqueous dispersion) |
- |
|
|
|
|
- |
- All test facilities are available as per the IS |
10628 |
BIS, Southern Regional Laboratory (SRL)
| IS 459 (1992) |
Corrugated and semi - Corrugated asbestos cement sheets - Specification (Third Revision) |
- |
- View breakup
Hence, testing charges (rounded to nearest Rs. 50.00) for the product is : 6000.00
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
5, Table 1 (Dimensions & Tolerances - Type of Sheet - cl. 5) |
- |
|
|
|
5, Table 1, Figure 1,2 (Dimensions & Tolerances - Depth of Corrugation, D - Cl. 5) |
- |
|
|
|
5, Table 1, Figure 1,2 (Dimensions & Tolerances - Pitch of Corrugation, P - Cl. 5) |
- |
|
|
|
5, Table 1, Figure 1,2 (Dimensions & Tolerances - Overall width, B - Cl. 5) |
- |
|
|
|
5, Table 1, Figure 1,2 (Dimensions & Tolerances - Effective Width, C - Cl. 5) |
- |
|
|
|
5, Table 1, Figure 1,2 (Dimensions & Tolerances - Nominal Thickness, T - Cl. 5) |
- |
|
|
|
5, Table 1, Figure 1,2 (Dimensions & Tolerances - Length of Sheet, A - Cl. 5) |
- |
|
|
|
6.1 (Load Bearing Capacity Test - Cl. 6.1, IS 5913) |
- |
|
|
|
7 (General Appearance and Finish - Cl. 7.1) |
- |
|
|
|
7 (General Appearance and Finish - Cl. 7.2) |
- |
|
|
|
12 (Marking - Indication of source of manufacture - Cl. 12) |
- |
|
|
|
12 (Marking - Year & Date of manufacture - Cl. 12) |
- |
|
|
|
12 (Marking - Pictorial warning signs as given in IS 12081 (Part 2) : 1987 - Cl. 12) |
- |
|
|
|
|
- |
- " 03 nos. "
Excluding optional tests,colouring matter |
10629 |
BIS Patna Branch Laboratory (PBL)
| IS 1489 : Part 2 (2015) |
Portland - Pozzolana cement - Specification: Part 2 calcined clay based |
- |
Rs.8420/- View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
6 - Table - 1 i (Insoluble residue - Cl 7.4 of IS 4032:1985) |
- |
|
|
|
6 - Table - 1 ii (Magnesia - Cl 7.2 of IS 4032:1985) |
- |
|
|
|
6 - Table - 1 iii (Total Sulphur Content calculated as Sulphuric Anhydride (SO3) - Cl 7.3 of IS 4032:1985) |
- |
|
|
|
6 - Table - 1 iv (Loss on ignition - Cl 7.1 of IS 4032:1985) |
- |
|
|
|
6 - Table - 1 v (Chloride content - Cl 4.13 of IS 4032:1985) |
- |
|
|
|
6 - Table - 1 vi ( Alkali content as (Na2O + 0.658 K2O) - Cl 4.11 of IS 4032:1985) |
- |
|
|
|
7 -Table 2- i (Fineness 4031 Part 2) |
- |
|
|
|
7 -Table 2- ii- a (Expansion by Le Chatelier- 4031 Part 3) |
- |
|
|
|
7 -Table 2- ii- a (Expansion after aeration - 4031 Part 3) |
- |
|
|
|
7 -Table 2- ii- b (Expansion by Autoclave- 4031 Part 3) |
- |
|
|
|
7 -Table 2- ii- b (Expansion after aeration- 4031 Part 3) |
- |
|
|
|
7 -Table 2- iii- a (Setting Time Initial- 4031 Part 5) |
- |
|
|
|
7 -Table 2-iii- b (Setting Time Final- 4031 Part 5) |
- |
|
|
|
7 -Table 2- iv- a (Compressive Strength At 72 hrs ± 1 hr - IS 4031 Part 6) |
- |
|
|
|
7 -Table 2- iv- b (Compressive Strength At 168 hrs ± 2 hr - IS 4031 Part 6) |
- |
|
|
|
7 -Table 2- iv- c (Compressive Strength At 672 hrs ± 4 hr - IS 4031 Part 6) |
- |
|
|
|
7 -Table 2- vi (Drying Shrinkage- IS 4031 Part 10) |
- |
|
|
|
|
- |
- All test facilities are available as per the IS except Transverse Strength Test (Clause 7 and Table-2) which is an optional test |
10630 |
BIS Patna Branch Laboratory (PBL)
| IS 1148 (2009) |
Steel Rivet Bars (medium And High Tensile)--For Structural Purposes--For Structural Purposes |
- |
- View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
Cl. 6 (Carbon- IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
|
|
|
Cl. 6 (Sulphur- IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
|
|
|
Cl. 6 (Phosphorus- IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
|
|
|
7 (FREEDOM FROM DEFECTS) |
- |
|
|
|
8 ( LENGTHS) |
- |
|
|
|
9 (DIMENSIONAL TOLERANCES) |
- |
|
|
|
11 (Tensile Test-1608:Part 1) |
- |
|
|
|
11 (Yield Strength, Mpa) |
- |
|
|
|
11 (Tensile Strength, Mpa) |
- |
|
|
|
11 (Elongation, %) |
- |
|
|
|
12 (Bend Test-1599) |
- |
|
|
|
|
- |
- All test facilities are available as per the IS except- i. Tests for microalloying elements (Nb, V, Ti and B) and Aluminium (Clause 6.2) ii. Shear Test (Clause 13)
iii. Hot Compression Test (Clause 14) |
10631 |
BIS Patna Branch Laboratory (PBL)
| IS 1079 (2017) |
Hot rolled carbon steel sheet, plate and strip - Specification (Seventh Revision) |
- |
- View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
8, Table 5 & 6 (Tensile Strength) |
- |
|
|
|
Cl 12 (Workmanship) |
- |
|
|
|
6.1 (Carbon %) |
- |
|
|
|
6.1 (Manganese %) |
- |
|
|
|
6.1 (Phosphorus %) |
- |
|
|
|
6.1 (Sulphur %) |
- |
|
|
|
6.1 (Silicon %) |
- |
|
|
|
6.1 ( Nitrogen%) |
- |
|
|
|
8, Table 5 & 6 (Yield Strength) |
- |
|
|
|
8, Table 5 & 6 (Elongation) |
- |
|
|
|
Clause 10 (Cuppping Test) |
- |
|
|
|
Clause 12 (Freedom from defect) |
- |
|
|
|
Clause 13 (Length) |
- |
|
|
|
14 (Calculation of weight) |
- |
|
|
|
Cl.13 (Out of square) |
- |
|
|
|
Cl.13 (Flatness) |
- |
|
|
|
Cl.13 (Camber) |
- |
|
|
|
Cl.13 (Width) |
- |
|
|
|
Cl.13 (Thickness) |
- |
|
|
|
|
- |
- All test facilities are available as per the IS except-
i. Cupping Test (Clause 10)
ii. Chemical tests for Boron, Titanium, Niobium, Vanadium, Aluminium and Copper (Clause 7.2) |
10632 |
MSME TESTING CENTRE (WR), MUMBAI
| IS 651 (2007) |
Glazed stoneware pipes and fittings - Specification (Sixth Revision) |
Class: SP1, SP2 & SP3 |
9500 View breakup
Complete test charges
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
5.1(GENERAL QUALITY) |
- |
500 |
|
Visual inspection |
7.2(Hydraulic Test) |
- |
2500 |
|
Hydraulic Test |
7.3(Absorption Test) |
- |
1500 |
|
Absorption Test |
Clause 7.4(Acid Resistance Test) |
- |
1000 |
|
Test for Acid Resistance |
Clause 7.5(Alkali Resistance Test) |
- |
1000 |
|
Test for Alkali Resistance |
|
- |
- - |
10633 |
BIS Patna Branch Laboratory (PBL)
| IS 10748 (2004) |
Hot - Rolled steel strip for welded tubes and pipes - Specification (Second Revision) |
- |
- View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
Cl 8 & Table 3 (UTM) |
- |
|
|
|
Cl 9 (Press) |
- |
|
|
|
Cl 11 (Workmanship) |
- |
|
|
|
Cl 12 & 13 (Length, Width & Thickness) |
- |
|
|
|
7.1 (Carbon %) |
- |
|
|
|
7.1 (Manganese %) |
- |
|
|
|
7.1 (Phosphorus %) |
- |
|
|
|
7.1 (Sulphur %) |
- |
|
|
|
Cl. 8, Table 3 (Yield Stress) |
- |
|
|
|
Cl. 14 (Weight) |
- |
|
|
|
Cl. 12, 13 (Camber) |
- |
|
|
|
Cl. 12, 13 (Thickness) |
- |
|
|
|
Cl. 8, Table 3 (Elongation) |
- |
|
|
|
7.1 (Silicon %) |
- |
|
|
|
7.1 (CE) |
- |
|
|
|
7.1 ( Nitrogen%) |
- |
|
|
|
|
- |
- All test facilities are available as per the IS except chemical tests for Chromium, Molybdenum,Vanadium, Nickel, Copper, Niobium, Boron, Titanium, Aluminium and Tungsten (Clause 7.2) |
10634 |
BIS Patna Branch Laboratory (PBL)
| IS 1038 (1983) |
Specification For Steel Doors, Windows And Ventilators |
- |
- View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
4.1. (Size-Height) |
- |
|
|
|
4.1 (Size-Width) |
- |
|
|
|
4.3 (Designation) |
- |
|
|
|
6.1 (Frames) |
- |
|
|
|
6.1.1.1 (Visual Inspection Test) |
- |
|
|
|
6.2 (Side Hung Shutter) |
- |
|
|
|
6.2 (Side Hung Shutter) |
- |
|
|
|
6.2 (Side Hung Shutter- Thickness of hinge) |
- |
|
|
|
6.2 (Side Hung Shutter- Pin diameter) |
- |
|
|
|
6.2 (Side Hung Shutter-Width of hinge) |
- |
|
|
|
6.2.2 & 6.2.2.1 (Handle and Handle Plate- Thicknesss of handle) |
- |
|
|
|
6.2.2 & 6.2.2.1 (Handle and Handle Plate-Height of handle plate) |
- |
|
|
|
6.2.3 (Peg Stay - Thickness) |
- |
|
|
|
6.2.3 (Peg Stay - Dimensions-A) |
- |
|
|
|
6.2.3 (Peg Stay - Dimensions-B) |
- |
|
|
|
6.2.3 (Peg Stay - Dimensions-C) |
- |
|
|
|
6.2.3 (Peg Stay - Dimensions-D) |
- |
|
|
|
6.2.3 (Peg Stay - Dimensions-E) |
- |
|
|
|
6.2.3 (Peg Stay - Dimensions-F) |
- |
|
|
|
6.2.3 (Peg Stay - Dimensions-G) |
- |
|
|
|
6.2.3 (Peg Stay - Dimensions-H) |
- |
|
|
|
6.2.3 (Peg Stay - Dimensions-J) |
- |
|
|
|
6.2.3 (Peg Stay - Dimensions-K) |
- |
|
|
|
6.2.3 (Peg Stay - Dimensions-L) |
- |
|
|
|
6.2.3 (Peg Stay - Dimensions-M) |
- |
|
|
|
6.3 (Top Hung Ventilator) |
- |
|
|
|
6.3 (Top Hung Ventilator-Thickness of hinge) |
- |
|
|
|
6.3 (Top Hung Ventilator-Pin diameter) |
- |
|
|
|
6.3 (Top Hung Ventilator-Width of hinge) |
- |
|
|
|
7.1 (Position of Holes) |
- |
|
|
|
7.2 Table 2 (Position of Fixing Screws) |
- |
|
|
|
7.2 Table 2 (Lugs-A) |
- |
|
|
|
7.2 Table 2 (Lugs-B) |
- |
|
|
|
7.2 Table 2 (Lugs-C) |
- |
|
|
|
7.2 Table 2 (Lugs-D) |
- |
|
|
|
7.2 Table 2 (Lugs-E) |
- |
|
|
|
7.2 Table 2 (Lugs-F) |
- |
|
|
|
7.2 Table 2 (Lugs-G) |
- |
|
|
|
8 (Finish) |
- |
|
|
|
9 (Glazing) |
- |
|
|
|
9 (Glazing- No of glazing clip against each plate) |
- |
|
|
|
|
- |
- All test facilities are available as per the IS |
10635 |
BIS, Southern Regional Laboratory (SRL)
| IS 13422 (1992) |
Disposable surgical rubber gloves specification |
- |
Rs.6900.00 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
5.4 (Sterility) |
- |
|
|
|
4 (TYPES) |
- |
|
|
|
5.2.1 (General Characteristics and Dimensions) |
- |
|
|
|
5.2.2 and Table 1
Fig. 1 (Dimensions - Length) |
- |
|
|
|
5.2.2 and Table 1
Fig. 1 (Dimensions - Width) |
- |
|
|
|
5.2.2 and Table 1
Fig. 1 (Dimensions - Thickness of Finger) |
- |
|
|
|
5.2.2 and Table 1
Fig. 1 (Dimensions - Thickness of Palm) |
- |
|
|
|
5.2.2 and Table 1
Fig. 1 (Dimensions - Thickness of Cuff) |
- |
|
|
|
5.3 and Table 2 ( Tensile Strength Before Ageing) |
- |
|
|
|
5.3 and Table 2 ( Elongation at Break Before Ageing) |
- |
|
|
|
5.3 and Table 2 (Stress at 500% Elongation at Break Before Ageing) |
- |
|
|
|
5.3 and Table 2 ( Tensile StrengthAfter Accelerated Ageing) |
- |
|
|
|
5.3 and Table 2 ( Elongation at Break After Accelerated Ageing) |
- |
|
|
|
5.5 (Airtight Test) |
- |
|
|
|
|
- |
- " Mech - 25 pairs, Micro - 3 pairs " |
10636 |
BIS, Northern Regional Laboratory (NRL)
| IS 1659 (2004) |
Block boards - Specification (Fourth Revision) |
- |
- View breakup
Rs 5900/- for BWR Grade, Rs.6800/- for MR grade
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
9.2.5 (Modulus of elasticity - MINIMUM INDIVIDUAL - Annexure K) |
- |
|
|
|
9.2.5 (Modulus of elasticity - AVERAGE - Annexure K) |
- |
|
|
|
9.2.5 (Modulus of rupture - MINIMUM INDIVIDUAL - Annexure K) |
- |
|
|
|
9.2.5 (Modulus of rupture - AVERAGE - Annexure K) |
- |
|
|
|
9.2.4 (Mycological Test [for MR grade only] - Annexure J) |
- |
|
|
|
9.2.2 (Resistance to water - Annexure G, Annexure H [For MR Grade]) |
- |
|
|
|
9.2.2 (Resistance to water - Annexure G, Annexure H [For BWP grade]) |
- |
|
|
|
9.2.1 (Dimensional Changes caused by humidity - Delamination - Annexure F) |
- |
|
|
|
9.2.1 (Dimensional Changes caused by humidity - Change in thickness - at 40% RH - Annexure F) |
- |
|
|
|
9.2.1 (Dimensional Changes caused by humidity - Change in Thickness - at 90% RH - Annexure F) |
- |
|
|
|
9.2.1 (Dimensional Changes caused by humidity - Change in Length - at 40% RH - Annexure F) |
- |
|
|
|
9.2.1 (Dimensional Changes caused by humidity - Change in Length - at 90% RH - Annexure F) |
- |
|
|
|
9.2.1 (Dimensional Changes caused by humidity - Change in thickness - at 40% RH - Annexure F) |
- |
|
|
|
9.2.1 (Dimensional Changes caused by humidity - Change in Thickness - at 90% RH - Annexure F) |
- |
|
|
|
9.2.1 (Dimensional Changes caused by humidity - Change in Length - at 40% RH - Annexure F) |
- |
|
|
|
9.2.1 (Dimensional Changes caused by humidity - Change in Length - at 90% RH - Annexure F) |
- |
|
|
|
7.3 (Dimensional Requirements - Variation in thickness - Annexure E) |
- |
|
|
|
7.3 (Dimensional Requirements - Squareness - Annexure D) |
- |
|
|
|
7.3 (Dimensional Requirements - Edge Straightness - Annexure D) |
- |
|
|
|
7.3 (Dimensional Requirements - Thickness - Annexure E) |
- |
|
|
|
7.3 (Dimensional Requirements - Width - 8.1.4) |
- |
|
|
|
7.3 (Dimensional Requirements - Length - 8.1.4) |
- |
|
|
|
8.1.3, 6.3.3, IS 1328 (Visual Inspection - Permissible Defects - IS 1328 [test method for DECORATIVE type]) |
- |
|
|
|
8.1.3, 6.3.3, IS 303 (Visual Inspection - Permissible Defects - IS 303 [test method for COMMERCIAL type]) |
- |
|
|
|
9.2.6 (Spot test - Annexure L) |
- |
|
|
|
8.1.3, 6.3.3, IS 1328 (Visual Inspection - Permissible Defects - IS 1328 [test method for DECORATIVE type]) |
- |
|
|
|
8.1.3, 6.3.3, IS 303 (Visual Inspection - Permissible Defects - IS 303 [test method for COMMERCIAL type]) |
- |
|
|
|
9.2.6 (Spot test - Annexure L) |
- |
|
|
|
9.2.3 (Adhesion of Plies - Annexure H) |
- |
|
|
|
9.2.1 (Dimensional Changes caused by humidity Change in local planeness - Annexure F) |
- |
|
|
|
9.2.6 (Spot test - Annexure L) |
- |
|
|
|
9.2.6 (mechanical) (Spot test - Annexure L) |
- |
|
|
|
|
- |
- Test facility is complete |
10637 |
BIS, Southern Regional Laboratory (SRL)
| IS 13334 : Part 2 (2014) |
Skimmed milk powder - Specification: Part 2 extra grade (First Revision) |
EXTRA GRADE |
Rs 10430/- View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
Table 1 (ix) (Bacterial count (IS 5402)) |
- |
|
|
|
Table 1 (x) (Coliform count (IS 5401 - Part 1)) |
- |
|
|
|
Table 1 (xi) (Escherichia coli (IS 5887 - Part 1)) |
- |
|
|
|
Table 1 (xii) (Coagulase positive Staphylococcus aureus (IS 5887 - Part 2)) |
- |
|
|
|
Table 1 (xiii) (Salmonella (IS 5887 - Part 3)) |
- |
|
|
|
Table 1 (xiv)(a) (Spore Count: a)Aerobic (Bacillus cereus) Type m (IS 5887 - Part 6)) |
- |
|
|
|
Table 1 (xiv)(b) (Spore Count: b) Anaerobic (Sulfite reducing Clostridia) Type m (ISO 15213 : 2003)) |
- |
|
|
|
Table 1 (xiv)(b) (Spore Count: b) Anaerobic (Sulfite reducing Clostridia) Type M (ISO 15213 : 2003)) |
- |
|
|
|
Table 1 (xv) (Listeria monocytogenes (IS 14988 - Part 2 : 2001)) |
- |
|
|
|
Table 1 (i) (Moisture (IS 116231or 16072)) |
- |
|
|
|
Table 1 (ii) (Milk protein in milk solids not fat (IS 72192)) |
- |
|
|
|
Table 1 (iii) (Milk fat (IS 117213) or Annex B) |
- |
|
|
|
Table 1 (iv) (Insolubility index (IS 12759)) |
- |
|
|
|
Table 1 (v) (Total ash (on dry basis), Annex B of IS 14433) |
- |
|
|
|
Table 1 (vi) (Titratable acidity (IS 11766)) |
- |
|
|
|
Table 1 (viii) (Scorched particles (equivalent to Disc B) (IS 13500)) |
- |
|
|
|
|
- |
- 2X500g
Excluding Except Lactate Content |
10638 |
BIS, Eastern Regional Laboratory (ERL)
| IS 398 : Part 5 (1992) |
Aluminium conductor for overhead transmission purposes - Specification: Part 5 aluminium conductors - Galvanized steel - Reinforced for extra high voltage (400 KV And Above) (First Revision) |
All sizes/varieties |
11400 View breakup
Excluding Breaking load on complete conductor, Surface condition test, Corona test and Radio interference test
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
7 (elec) (Freedom from
defects) |
- |
|
|
|
13.5.1 Table 3 (elec) (Breaking Load on Complete conductor) |
- |
|
|
|
13.5.2 Table 1 (elec) (Breaking Load of Aluminium Wires Before Stranding) |
- |
|
|
|
13.5.2 Table 2 (elec) (Breaking Load of Steel Wires Before Stranding) |
- |
|
|
|
13.5.2 Table 1 (elec) (Breaking Load of Aluminium Wires After Stranding) |
- |
|
|
|
13.5.2 Table 2 (elec) (Breaking Load of Steel Wires After Stranding) |
- |
|
|
|
13.6.1 (elec) (Ductility by Torsion Test before stranding) |
- |
|
|
|
13.6.1 (elec) (Ductility by Torsion Test after stranding) |
- |
|
|
|
13.6.2 (elec) (Ductility by Elongation Test before stranding) |
- |
|
|
|
13.6.2 (elec) (Ductility by Elongation Test after stranding) |
- |
|
|
|
13.7.1 (elec) (Wrapping Test Aluminium Wires Before Stranding) |
- |
|
|
|
13.7.1 (elec) (Wrapping Test Aluminium Wires After Stranding) |
- |
|
|
|
13.7.2 (elec) (Wrapping Test Galvanized Steel Wires Before Stranding) |
- |
|
|
|
13.7.2 (elec) (Wrapping Test Galvanized Steel Wires After Stranding) |
- |
|
|
|
13.8 (elec) (Resistance test-Aluminium wire before Stranding) |
- |
|
|
|
14.8 (elec) (Resistance test-Aluminium wire after stranding) |
- |
|
|
|
13.9.2 (elec) (Mass of Zinc coating) |
- |
|
|
|
10.4 (elec) (Direction of lay) |
- |
|
|
|
13.4 Table-4 (elec) (Lay Ratio- Aluminium Wire Outermost Layer) |
- |
|
|
|
13.4 Table-4 (elec) (Lay Ratio- Aluminium Wire Layer Immediately Beneath Outermost Layer) |
- |
|
|
|
13.4 Table-4 (mech) (Lay Ratio- Aluminium Wire Innermost Layer of Conductors eith 3 Aluminium Wire Layers) |
- |
|
|
|
13.4 Table-4 (elec) (Lay Ratio- Steel Core (6 Wire Layer)) |
- |
|
|
|
13.3 Table-2 (elec) (Diameter-Galvanized Steel wires) |
- |
|
|
|
13.3 Table-1 (elec) (Diameter-Aluminium wires) |
- |
|
|
|
13.10 (elec) (Surface condition test) |
- |
|
|
|
13.11 (elec) (Corona Test) |
- |
|
|
|
13.12 (elec) (Radio Interference Voltage Test) |
- |
|
|
|
13.4 Table-4 (elec) (Lay Ratio- Steel Core (6 Wire Layer)) |
- |
|
|
|
8.2.2 (elec) (Resistance of complete conductor) |
- |
|
|
|
13.2 (elec) (Visual Examination) |
- |
|
|
|
13.4 Table-4 (elec) (Lay Ratio- Aluminium Wire Innermost Layer of Conductors eith 3 Aluminium Wire Layers) |
- |
|
|
|
|
- |
- Elec-Facility not available for surface condition,corona test ,radio interference test, Breaking Load on complete conductor. |
10639 |
BIS, Northern Regional Laboratory (NRL)
| IS 2062 (2011) |
Hot rolled medium and high tensile structural steel - Specification (Seventh Revision) |
- |
- View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
Cl 18 (Weight) |
- |
|
|
|
Cl 15 (Length, Width & Thickness) |
- |
|
|
|
Cl 11.3 (Press) |
- |
|
|
|
Cl 10.3 (UTM) |
- |
|
|
|
Cl 7 (Workmanship) |
- |
|
|
|
Cl 7 (Workmanship) |
- |
|
|
|
Cl 7 (Workmanship) |
- |
|
|
|
Clause - 5, 8.1 & 8.2 (E250, CARBON) |
- |
|
|
|
Clause - 5, 8.1 & 8.2 (E250, SULPHUR) |
- |
|
|
|
Clause - 5, 8.1 & 8.2 (E250, SILICON) |
- |
|
|
|
Clause - 5, 8.1 & 8.2 (E250 ,MANGANESE) |
- |
|
|
|
Clause - 5, 8.1 & 8.2 (E250, PHOSPHURS) |
- |
|
|
|
Clause - 5, 8.1 & 8.2 (E250, NITROGEN) |
- |
|
|
|
Clause - 5, 8.1 & 8.2 (E250, CARBON +EQUIVELENT ) |
- |
|
|
|
Clause - 5, 8.1 & 8.2 (E275, CARBON +EQUIVELENT ) |
- |
|
|
|
Clause - 5, 8.1 & 8.2 (E300, CARBON +EQUIVELENT ) |
- |
|
|
|
Clause - 5, 8.1 & 8.2 (E350, CARBON +EQUIVELENT ) |
- |
|
|
|
Clause - 5, 8.1 & 8.2 (E410, CARBON +EQUIVELENT ) |
- |
|
|
|
Clause - 5, 8.1 & 8.2 (E450, CARBON +EQUIVELENT ) |
- |
|
|
|
Clause - 5, 8.1 & 8.2 (E550, CARBON +EQUIVELENT ) |
- |
|
|
|
Clause - 5, 8.1 & 8.2 (E600, CARBON +EQUIVELENT ) |
- |
|
|
|
Clause - 5, 8.1 & 8.2 (E250, CARBON +EQUIVELENT ) |
- |
|
|
|
Clause - 5, 8.1 & 8.2 (E410, NITROGEN) |
- |
|
|
|
Clause - 5, 8.1 & 8.2 (E410, SILICON) |
- |
|
|
|
Clause - 5, 8.1 & 8.2 (E450 ,MANGANESE) |
- |
|
|
|
Clause - 5, 8.1 & 8.2 (E410, PHOSPHURS) |
- |
|
|
|
Clause - 5, 8.1 & 8.2 (E410, SULPHUR) |
- |
|
|
|
Clause - 5, 8.1 & 8.2 (E410, CARBON) |
- |
|
|
|
Clause - 5, 8.1 & 8.2 (E410, CARBON +EQUIVELENT ) |
- |
|
|
|
Cl. 15 (Cl. 15 Square Bar: Out of Square) |
- |
|
|
|
Cl. 15 (Cl. 15 Square Bar: Side Width: Minimum) |
- |
|
|
|
Cl. 15 (Cl. 15 Square Bar: Side Width: Maximum) |
- |
|
|
|
Cl. 15, 16 (Thickness ) |
- |
|
|
|
Cl. 15, 16 (Toe Radius R2) |
- |
|
|
|
15 (Radius R1) |
- |
|
|
|
Cl. 15, 16 (Leg Length Difference (Angle)) |
- |
|
|
|
Cl. 15, 16 (Leg Length B (Angle)) |
- |
|
|
|
Cl. 15, 16 (Leg Length A (Angle)) |
- |
|
|
|
Cl. 15, 16 (Camber (Angle)) |
- |
|
|
|
Cl 13 (Y Groove Cracking Test) |
- |
|
|
|
Clause 12 (Impact Test) |
- |
|
|
|
Cl. 15, 16 (Flange Slope) |
- |
|
|
|
Cl. 15, 16 (Web Thickness) |
- |
|
|
|
Cl. 15, 16 (Flange Thickness) |
- |
|
|
|
Cl. 15, 16 (Out of Square (Flat)) |
- |
|
|
|
Cl. 15, 16 (Width ) |
- |
|
|
|
Cl. 15, 16 (Thickness ) |
- |
|
|
|
|
- |
- Except Microalloying Elements |
10640 |
BIS, Eastern Regional Laboratory (ERL)
| IS 398 : Part 4 (1994) |
Aluminium conductors for overhead transmission purposes: Part 4 aluminium alloy stranded conductors (Aluminium - Magnesium - Silicon Type) - Specification (Third Revision) |
Complete facility available upto 100 sq mm only |
Rs 825/- upto 7 wires, Rs 1425/- upto 19 wires View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
6.1 (Freedom from Defects) |
- |
|
|
|
7.2.2 Table-2, Table-4 (Calculated resistance of Stranded Conductor) |
- |
|
|
|
8.1 (Joints in wires-Conductors Containing Seven Wires) |
- |
|
|
|
8.2 (Joints in wires-Conductors Containing More Than Seven Wires) |
- |
|
|
|
9.2 Table 3 (Lay Ratio of stranded conductors) |
- |
|
|
|
9.3 (Direction of Lay) |
- |
|
|
|
9.4 (Multiple layers of wires) |
- |
|
|
|
12.2 Table 1 (Breaking Load Test- Before Stranding) |
- |
|
|
|
12.2 Table 1 (Breaking Load Test- After Stranding) |
- |
|
|
|
12.3 Table 1 (Elongation Test- Before Stranding) |
- |
|
|
|
12.3 Table 1 (Elongation Test- After Stranding) |
- |
|
|
|
12.4 Table 1 (Resistance of Aluminium wire) |
- |
|
|
|
11 (Packing and Marking) |
- |
|
|
|
7.1 Table-1 (Dimensional measurement of wires) |
- |
|
|
|
9.1 (Stranding) |
- |
|
|
|
|
- |
- Elec-Complete facility available upto 100 sq mm only. For Above 100 sq.mm. facility not available for Stress-Strain Test, Surface Condition, Ultimate B/L on stranded conductor. |
10641 |
BIS, Central Laboratory (CL)
| IS 694 (2010) |
Polyvinyl chloride insulated unsheathed and sheathed cables/cords with rigid and flexible conductor for rated voltages up to and including 450/750 v (Fourth Revision) |
- |
- View breakup
For category 01 Unsheathed cable: A Single Core, Plain Copper Conductor Rs. 10500/- B Single Core, Tinned Copper Conductor Rs.10800/- C Single Core, Solid Aluminium Conductor Rs.10200/- D Single Core, Stranded Aluminium ConductorRs.10200/- Sheathed Cable: A Single Core, Plain Copper Conductor Rs. 17550/- B Single Core, Tinned Copper Conductor Rs.17850/- C Single Core, Solid Aluminium ConductorRs.17250/- D Single Core, Stranded Aluminium Conductor Rs.17250/- For category 02 Unsheathed Cable: A Single Core, Plain Copper Conductor ?12150/- B Single Core, Tinned Copper Conductor ?12450/- C Single Core, Solid Aluminium Conductor ?11850/- D Single Core, Stranded Aluminium Conductor ?11850/- Sheathed Cable: A Single Core, Plain Copper Conductor ?18900/- B Single Core, Tinned Copper Conductor ?19200/- C Single Core, Solid Aluminium Conductor ?18600/- D Single Core, Stranded Aluminium Conductor ?18600/- For FR cables Unsheathed Cable: A Single Core, Plain Copper Conductor ?12600/- B Single Core, Tinned Copper Conductor ?12900/- C Single Core, Solid Aluminium Conductor ?12300/- D Single Core, Stranded Aluminium Conductor ?12300/- Sheathed Cable: A Single Core, Plain Copper Conductor ?19650/- B Single Core, Tinned Copper Conductor ?19950/- C Single Core, Solid Aluminium Conductor ?19350/- D Single Core, Stranded Aluminium Conductor ?19350/- For FR-LSH cables Unsheathed Cable A Single Core, Plain Copper Conductor ?13950/- B Single Core, Tinned Copper Conductor ?14250/- C Single Core, Solid Aluminium Conductor ?13650/- D Single Core, Stranded Aluminium Conductor ?13650/- Sheathed Cable: A Single Core, Plain Copper Conductor ?20820/- B Single Core, Tinned Copper Conductor ?21120/- C Single Core, Solid Aluminium Conductor ?20520/- D Single Core, Stranded Aluminium Conductor ?20520/- Material testing charges as per relevant referred Iss (For each of the above category). For multi core cable: for each additional core, the changes of single core unsheathed cable as per material (copper & aluminum) and as per construction of conductor (solid or standard, tinned or plain) shall be added
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
4.1 (Conductor - Material) |
- |
|
|
|
4.1 (Tensile test (for Al)-Before Stranding) |
- |
|
|
|
4.1 (Tensile test (for Al)- After Stranding) |
- |
|
|
|
4.1 (Annealing test (for copper)) |
- |
|
|
|
4.1 (Wrapping test (for Al)) |
- |
|
|
|
4.2 (Conductor resistance test) |
- |
|
|
|
5.1 (Insulation) |
- |
|
|
|
5.2 (Application ) |
- |
|
|
|
5.3 (Thickness of Insulation) |
- |
|
|
|
6.1 (Filler) |
- |
|
|
|
6.2 (Filler) |
- |
|
|
|
7 (Binder Tape) |
- |
|
|
|
8.1 (Sheath Material ) |
- |
|
|
|
8.3 (Thickness of Sheath) |
- |
|
|
|
9 (Overall dimensions) |
- |
|
|
|
9.1 (Ovality) |
- |
|
|
|
10.1 (HV (water immersion)) |
- |
|
|
|
10.2 (HV (room temperature)) |
- |
|
|
|
10.4 (Flammability test-Burning after flame removal) |
- |
|
|
|
10.4 (Flammability test- Unaffected portion) |
- |
|
|
|
10.9 (Additional ageing test (OU cables only) -HV test (at 60±3oC)) |
- |
|
|
|
10.11 (Per sulphate test (for tinned Cu cable only)) |
- |
|
|
|
11 (Identification) |
- |
|
|
|
11.1 (Durability) |
- |
|
|
|
11.2 (Legibility) |
- |
|
|
|
12 (CONSTRUCTION Core Identification) |
- |
|
|
|
Table 1 iii) c) 1) (Tensile strength (Without ageing)) |
- |
|
|
|
Table 1 iii) c) 1) (Elongation (Without ageing)) |
- |
|
|
|
Table 1 iii) c) 2) (Loss of mass- Insulation ) |
- |
|
|
|
Table 1 iii) c) 3) (Tensile strength (After ageing)) |
- |
|
|
|
Table 1 iii) c) 3) (TS variation) |
- |
|
|
|
Table 1 iii) c) 3) (Elongation (After ageing)) |
- |
|
|
|
Table 1 iii) c) 3) (Elongation variation) |
- |
|
|
|
Table 1 iii) c) 4) (Shrinkage-Insulation) |
- |
|
|
|
Table 1 iii) c) 4) (Cracks Observed) |
- |
|
|
|
Table 1 iii) c) 5) (Heat shock-Insulation ) |
- |
|
|
|
Table 1 iii) c) 6) (Hot deformation - Indentation depth- Insulation) |
- |
|
|
|
Table 1 iii) c) 7) (Thermal stability- Insulation ) |
- |
|
|
|
Table 1 iii) c) 8) (Cold bend for insulation) |
- |
|
|
|
Table 1 iii) c) 9) (Cold impact for insulation) |
- |
|
|
|
Table 1 iii) d) 1) (Sheath -Tensile strength (Without ageing)) |
- |
|
|
|
Table 1 iii) d) 1) (Sheath- Elongation (Without ageing)) |
- |
|
|
|
Table 1 iii) d) 2) (Loss of mass- Sheath ) |
- |
|
|
|
Table 1 iii) d) 3) (Sheath- Tensile strength (After ageing)) |
- |
|
|
|
Table 1 iii) d) 3) (Sheath- TS variation) |
- |
|
|
|
Table 1 iii) d) 3) (Sheath- Elongation (After ageing)) |
- |
|
|
|
Table 1 iii) d) 3) (Sheath- Elongation variation) |
- |
|
|
|
Table 1 iii) d) 4) (Shrinkage- Sheath ) |
- |
|
|
|
Table 1 iii) d) 4) (Cracks Observed) |
- |
|
|
|
Table 1 iii) d) 5) (Heat shock-Sheath ) |
- |
|
|
|
Table 1 iii) d) 6) (Hot deformation -Indentation depth - Sheath ) |
- |
|
|
|
Table 1 iii) d) 7) (Thermal stability- Sheath ) |
- |
|
|
|
Table 1 iii) d) 8) (Cold bend for sheath) |
- |
|
|
|
Table 1 iii) d) 9) (Cold impact for sheath) |
- |
|
|
|
table 1 e) 3) (Volume Resistivity - Room temp ) |
- |
|
|
|
table 1 e) 3) (Volume Resistivity - Maximum temp) |
- |
|
|
|
table 1 e) 3) (IR constant- Room temp ) |
- |
|
|
|
table 1 e) 3) (IR constant- max. Temp) |
- |
|
|
|
Table 1 iii) c) 8) (Cold bend for insulation) |
- |
|
|
|
Table 1 iii) c) 9) (Cold impact for insulation) |
- |
|
|
|
Table 1 iii) d) 8) (Cold bend for sheath) |
- |
|
|
|
Table 1 iii) d) 9) (Cold impact for sheath) |
- |
|
|
|
Table 1 (Category Code) |
- |
|
|
|
10.11 (Persulphate Test ) |
- |
|
|
|
4.1 (Conductor - Material) |
- |
|
|
|
4.1 (Conductor - Material) |
- |
|
|
|
4.1 (Conductor - Material) |
- |
|
|
|
8 (SHEATH) |
- |
|
|
|
18 (SINGLE AND MULTICORE CIRCULAR PVC INSULATED
AND SHEATHED CABLES WITH RIGID CONDUCTOR (CLASS 1 AND CLASS 2) FOR GENERAL PURPOSE ) FOR MAXIMUM CONDUCTOR TEMPERATURE (70°C OR 85°C)) |
- |
|
|
|
4.1 (Material) |
- |
|
|
|
(4.3 of IS 8130:2013) (Form of Conductor) |
- |
|
|
|
( 4.4.1 of IS 8130:2013) (Joints in Conductor) |
- |
|
|
|
(4.4.2 of IS 8130:2013) (Joints in Conductor Solid Conductors (Aluminium Conductors only)) |
- |
|
|
|
(Cl.6.1.1 of IS 8130:2013) (Solid Conductor (Class 1)) |
- |
|
|
|
(Cl.6.1.2 of IS 8130:2013) (Solid Conductor (Class 1)) |
- |
|
|
|
(Cl.6.1.3 of IS 8130:2013) (Solid Conductor (Class 1)) |
- |
|
|
|
(6.2.1 of IS 8130:2013) (Stranded Circular Non-compacted Conductors (Class 2)) |
- |
|
|
|
(6.2.2 of IS 8130:2013) (Stranded Circular Non-compacted Conductors (Class 2)) |
- |
|
|
|
(6.2.3 of IS 8130:2013) (Stranded Circular Non-compacted Conductors (Class 2)) |
- |
|
|
|
(6.3.1 of IS 8130:2013) (Stranded Compacted Circular Conductors and Shaped Conductors (Class 2)) |
- |
|
|
|
(6.3.2 of IS 8130:2013) (Stranded Compacted Circular Conductors and Shaped Conductors (Class 2)) |
- |
|
|
|
(6.3.3 of IS 8130:2013) (Stranded Compacted Circular Conductors and Shaped Conductors (Class 2)) |
- |
|
|
|
( 6.4.1 of IS 8130:2013) (Flexible Conductors (Class 5)) |
- |
|
|
|
(6.4.2 of IS 8130:2013) (Flexible Conductors (Class 5)) |
- |
|
|
|
( 6.4.3 of IS 8130:2013) (Flexible Conductors (Class 5)) |
- |
|
|
|
Cl.19.1.4 (Assembly of Cores) |
- |
|
|
|
Cl. 8.2 (Application of Sheath) |
- |
|
|
|
|
- |
- Test facility not available for FR, FR-LSH category. |
10642 |
BIS, Northern Regional Laboratory (NRL)
| IS 2202 : Part 1 (1999) |
Wooden flush door shutters (Solid Core Type) - Specification: Part 1 plywood face panels (Sixth Revision) |
- |
- View breakup
Rs. 37654/- for type tests Rs. 8304/- for acceptance test Material testing charges to be levied as per relevant referred Iss.
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
11.1 (Height - IS 4020 (Pt-2)) |
- |
|
|
|
11.1 (Width- IS 4020 (Pt-2)) |
- |
|
|
|
11.1 (Thickness - IS 4020 (Pt-2)) |
- |
|
|
|
11.1 ( Squareness Test - IS 4020 (Pt-2)) |
- |
|
|
|
11.2 ( Twist, cupping & wrapping - IS 4020 (Pt-3)) |
- |
|
|
|
11.3 (Depth of deviation - IS 4020(Pt-4)) |
- |
|
|
|
11.4 (Impact Indentation Test - IS 4020(Pt-5)) |
- |
|
|
|
11.4 (Depth of indentation - IS 4020(Pt-5)) |
- |
|
|
|
11.5 (Deflection at maximum load - IS 4020(Pt-6)) |
- |
|
|
|
11.5 (Residual deflection - IS 4020(Pt-6)) |
- |
|
|
|
11.6 (Deflection of the edge at maximum load - IS 4020(Pt-7)) |
- |
|
|
|
11.6 (Residual deflection after removal of load - IS 4020(Pt-7)) |
- |
|
|
|
11.6 (Lateral buckling during loading - IS 4020(Pt-7)) |
- |
|
|
|
11.6 (Residual lateral buckling - IS 4020(Pt-7)) |
- |
|
|
|
11.8 (Buckling Test - IS 4020(Pt-9)) |
- |
|
|
|
11.8 (Initial deflection - IS 4020(Pt-9)) |
- |
|
|
|
11.8 (Residual deformation after 15 minutes of unloading - IS 4020(Pt-9)) |
- |
|
|
|
11.9 (Slamming Test - IS 4020(Pt-10)) |
- |
|
|
|
11.1 (Misuse Test - IS 4020(Pt-11)) |
- |
|
|
|
11.11 (Varying Humidity Test - IS 4020(Pt-12)) |
- |
|
|
|
11.11 (Maximum departure from the general planeness - IS 4020(Pt-12)) |
- |
|
|
|
11.11 (The recovery of the original size after subjecting the door to high and low humidity- IS 4020(Pt-12)) |
- |
|
|
|
11.14 (Glue Adhesion Test - IS 4020(Pt-15)) |
- |
|
|
|
11.15 (Screw Withdrawal Strength - IS 4020 (Pt-16)) |
- |
|
|
|
6.2 (Plywood) |
- |
|
|
|
11.13 (Knife Test - IS 4020(Pt-14)) |
- |
|
|
|
9.2 (Workmanship & finish - IS 2202(Pt-1)) |
- |
|
|
|
9.3 (Workmanship & finish - IS 2202(Pt-1)) |
- |
|
|
|
11.7 (Shock Resistance Test -IS 4020(Pt-8)) |
- |
|
|
|
11.12 (End Immersion Test - IS 4020(Pt-13)) |
- |
|
|
|
11.13 (Knife Test - IS 4020(Pt-14)) |
- |
|
|
|
9.2 (Workmanship & finish - IS 2202(Pt-1)) |
- |
|
|
|
9.3 (Workmanship & finish - IS 2202(Pt-1)) |
- |
|
|
|
11.7 (Shock Resistance Test -IS 4020(Pt-8)) |
- |
|
|
|
11.12 (End Immersion Test - IS 4020(Pt-13)) |
- |
|
|
|
11.1 (Variation in thickness - IS 4020 (Pt-2)) |
- |
|
|
|
|
- |
- Standard revised in 2023.Test facility is complete. |
10643 |
BIS, Central Laboratory (CL)
| IS 15658 (2006) |
Precast concrete blocks for paving - Specification |
- |
Rs.15940/- View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
6.2.4 (WATER ABSORPTION TEST (Average for three test specimens)) |
- |
|
|
|
6.2.5 (AVERAGE COMPRESSIVE STRENGTH (Average for eight test specimens) ) |
- |
|
|
|
|
- |
- Excluding -; Abrasion Resistance Test a ( Dry & Wet) |
10644 |
BIS, Central Laboratory (CL)
| IS 269 (2015) |
Ordinary portland cement - Specification (Sixth Revision) |
- |
- View breakup
Testing charges) for the product are: i) Including Transverse Strength (optional test) test 9,700.00 ii) Excluding Transverse Strength (optional test) test 8,500.00 -Testing charges for only chemical test report: 4,900.00 -Testing charges for only physical test report including optional tests: 4,800.00 -Testing charges for only physical test report excluding optional tests: 3,600.00
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
6.1 Table-2 viii (Alkali content) |
- |
|
|
|
6.1 Table-2 vii (Chloride content) |
- |
|
|
|
6.1 Table-2 vi (Loss on ignition) |
- |
|
|
|
6.1 Table-2 v (Total Sulphur Content calculated as Sulphuric Anhydride) |
- |
|
|
|
6.1 Table-2 iv (Magnesia) |
- |
|
|
|
6 - Table - 1 i (Ratio of percentage of lime to percentages of silica, alumina and iron oxide - Cl 4 of IS 4032:1985) |
- |
|
|
|
6.1 Table-2 iii. (Insoluble residue) |
- |
|
|
|
6.1 Table-2 ii. (Ratio of percentage of alumina to that of iron oxide) |
- |
|
|
|
6.1 Table-2 viii (Alkali content) |
- |
|
|
|
6.1 Table-2 vii (Chloride content) |
- |
|
|
|
6.1 Table-2 vi (Loss on ignition) |
- |
|
|
|
6.1 Table-2 v (Total Sulphur Content calculated as Sulphuric Anhydride) |
- |
|
|
|
6.1 Table-2 iv (Magnesia) |
- |
|
|
|
6 - Table - 1 i (Ratio of percentage of lime to percentages of silica, alumina and iron oxide - Cl 4 of IS 4032:1985) |
- |
|
|
|
6.1 Table-2 iii. (Insoluble residue) |
- |
|
|
|
6.1 Table-2 ii. (Ratio of percentage of alumina to that of iron oxide) |
- |
|
|
|
7 Table-3 iv c (Compressive Strength At 672 hrs ± 4 hr - IS 4031 Part 6) |
- |
|
|
|
7 Table-3 iv b (Compressive Strength At 168 hrs ± 2 hr - IS 4031 Part 6) |
- |
|
|
|
7 Table-3 iv a (Compressive Strength At 72 hrs ± 1 hr - IS 4031 Part 6) |
- |
|
|
|
7 Table-3 iii b (Setting Time Final) |
- |
|
|
|
7 Table-3 iii a (Setting Time Initial) |
- |
|
|
|
7 Table-3 ii b (Expansion by Autoclave) |
- |
|
|
|
7 Table-3 ii a (Expansion by Le Chatelier) |
- |
|
|
|
7 Table-3 i. (Fineness) |
- |
|
|
|
|
- |
- Excluding Table 2,Clause 6.1 ,sl. no.(viii) , alkali content; |
10645 |
BIS, Northern Regional Laboratory (NRL)
| IS 269 (2015) |
Ordinary portland cement - Specification (Sixth Revision) |
- |
- View breakup
Testing charges) for the product are: i) Including Transverse Strength (optional test) test 9,700.00 ii) Excluding Transverse Strength (optional test) test 8,500.00 -Testing charges for only chemical test report: 4,900.00 -Testing charges for only physical test report including optional tests: 4,800.00 -Testing charges for only physical test report excluding optional tests: 3,600.00
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
7 Table-3 i. (Fineness) |
- |
|
|
|
7 Table-3 i. (Fineness) |
- |
|
|
|
7 Table-3 ii a (Expansion by Le Chatelier) |
- |
|
|
|
7 Table-3 ii b (Expansion by Autoclave) |
- |
|
|
|
7 Table-3 iii a (Setting Time Initial) |
- |
|
|
|
7 Table-3 iii b (Setting Time Final) |
- |
|
|
|
7 Table-3 iv a (Compressive Strength At 72 hrs ± 1 hr - IS 4031 Part 6) |
- |
|
|
|
7 Table-3 iv b (Compressive Strength At 168 hrs ± 2 hr - IS 4031 Part 6) |
- |
|
|
|
7 Table-3 iv c (Compressive Strength At 672 hrs ± 4 hr - IS 4031 Part 6) |
- |
|
|
|
6.1 Table-2 vi (Loss on ignition) |
- |
|
|
|
6.1 Table-2 viii (Alkali content) |
- |
|
|
|
6.1 Table-2 vii (Chloride content) |
- |
|
|
|
6.1 Table-2 v (Total Sulphur Content calculated as Sulphuric Anhydride) |
- |
|
|
|
6.1 Table-2 iv (Magnesia) |
- |
|
|
|
6.1 Table-2 iii. (Insoluble residue) |
- |
|
|
|
6.1 Table-2 ii. (Ratio of percentage of alumina to that of iron oxide) |
- |
|
|
|
6 - Table - 1 i (Ratio of percentage of lime to percentages of silica, alumina and iron oxide - Cl 4 of IS 4032:1985) |
- |
|
|
|
|
- |
- Test Facility is complete for Chemical.
Test Facility is complete except Transverse Strength Test |
10646 |
BIS, Southern Regional Laboratory (SRL)
| IS 12818 (2010) |
Unplasticized polyvinyl chloride (Pvc - U) screen and casing pipes for bore/tubewells - Specification (Second Revision) |
- |
- View breakup
Rs 6450/- Excluding effect on water test
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
9.6 (Vicat Softening Temperature
IS 12235 (Part 2).) |
- |
|
|
|
9.3 (Density
IS 12235 (Part 14)) |
- |
|
|
|
9.1 ( Visual Appearance) |
- |
|
|
|
7.2 and Table 5, 6 & 7
Fig 1B (Wall thickness, Min) |
- |
|
|
|
7.2 and Table 5, 6 & 7
Fig 1B (Mean Outer Diameter over Connection) |
- |
|
|
|
7.1 and Table 1, 2, 3, & 4
Fig 1A & 1B (Outer Diameter at any point ) |
- |
|
|
|
7.2 and Table 5, 6 & 7
Fig 1B (Mean Outer Diameter of Pipe, Min) |
- |
|
|
|
7.1 and Table 1, 2, 3, & 4
Fig 1A & 1B (Mean Outer Diameter of Pipe) |
- |
|
|
|
7.2 and Table 5, 6 & 7
Fig 1B (Mean Outer Diameter of Pipe , Max) |
- |
|
|
|
7.2 and Table 5, 6 & 7
Fig 1B (Outer Diameter at any point , Min) |
- |
|
|
|
8.4 (Sealing rings - Hardness) |
- |
|
|
|
9.1 ( Visual Appearance) |
- |
|
|
|
5 (COLOUR) |
- |
|
|
|
8.4.1 and Table 13
Fig 3B & 4B (Dimensions of sealing elements) |
- |
|
|
|
7.4 Table 8 & 9
Fig 1 (Effective length, l2) |
- |
|
|
|
7.4 Table 8 & 9
Fig 1 (Segmental length, l3) |
- |
|
|
|
7.4 Table 8 & 9
Fig 1 (Segmental length, l4) |
- |
|
|
|
7.4 Table 8 & 9
Fig 1 (Segmental length, l5) |
- |
|
|
|
7.3.1 (No.of Ribs) |
- |
|
|
|
7.3.2 (Rib height) |
- |
|
|
|
|
- |
- " 6 mts, 2 Gaskets and 5 Hardness button
Excluding Excl. Tensile test, reistance to external blows at 0°C , Effect on Water, thread gauges |
10647 |
BIS, Central Laboratory (CL)
| IS 710 (2010) |
Marine plywood - Specification (Second Revision) |
- |
Rs 11200/- View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
7.1 (WORKMANSHIP AND FINISH ) |
- |
|
|
|
7.2 (WORKMANSHIP AND FINISH ) |
- |
|
|
|
7.3 (WORKMANSHIP AND FINISH ) |
- |
|
|
|
7.5 (WORKMANSHIP AND FINISH ) |
- |
|
|
|
6.1 (DIMENSIONS) |
- |
|
|
|
6.2 (DIMENSIONS) |
- |
|
|
|
6.3 (DIMENSIONS) |
- |
|
|
|
9.1.1 (MOISTURE CONTENT) |
- |
|
|
|
9.1.2 , 9.1.2.1 (Glue Adhesion in Dry State) |
- |
|
|
|
9.1.2 , 9.1.2.2 (Glue Adhesion in Dry State) |
- |
|
|
|
9.1.3 , 9.1.3.1.1 (Water resistance test) |
- |
|
|
|
9.1.3 , 9.1.3.1.2 (Water resistance test) |
- |
|
|
|
9.1.5 (Mycological test) |
- |
|
|
|
9.1.4 (Tensile strength) |
- |
|
|
|
9.1.6 (Table 3) (Static bending strength) |
- |
|
|
|
9.1.6 (Table 3) (Static bending strength) |
- |
|
|
|
9.1.7 (Table 4) (Wet bending strength) |
- |
|
|
|
9.1.7 (Table 4) (Wet bending strength) |
- |
|
|
|
9.1.8 (Retention of preservative) |
- |
|
|
|
11.1 (MARKING) |
- |
|
|
|
|
- |
- - |
10648 |
BIS, Central Laboratory (CL)
| IS 12786 (1989) |
Irrigation equipment - Polyethylene pipes for irrigation laterals - Specification |
- |
- View breakup
Rs. 7800.00 (Excluding Testing Charges for Material Test) Rs. 3600.00 (Testing Charges for Material Test)
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
7.3 (Tensile Test) |
- |
|
|
|
7.3 (Elongation at Break) |
- |
|
|
|
4.1.c & 4.2.a (Carbon Black content - IS 2530 : 1963) |
- |
|
|
|
|
- |
- Excluding Environmental strees cracking resistance test and Cl 7.1 & Table 2 Hydraulic test; |
10649 |
BIS, Central Laboratory (CL)
| IS 14151 : Part 2 (2008) |
Irrigation equipment - Sprinkler pipes - Specification: Part 2 quick coupled polyethylene pipes and fittings (Second Revision) |
- |
- View breakup
Rs. 4250/-(Excluding leakage test and Hyd. Proof Test)+Testing charges as per IS 14151(Part 1)
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
7.2.1 (Visual and Workmanship Requirement) |
- |
|
|
|
4.2.7 (1 Dimensions of Quick Coupled Pipes and Fittings) |
- |
|
|
|
|
- |
- - |
10650 |
BIS, Central Laboratory (CL)
| IS 1489 (Part 1) (2015) |
Portland pozzolana cement - Specification: Part 1 fly Ash Based |
- |
- View breakup
Rs.8420/-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
6 - Table - 1 v (Chloride content - Cl 4.13 of IS 4032:1985) |
- |
|
|
|
6 - Table - 1 iv (Loss on ignition - Cl 7.1 of IS 4032:1985) |
- |
|
|
|
6 - Table - 1 i (Insoluble residue - Cl 7.4 of IS 4032:1985) |
- |
|
|
|
6 - Table - 1 iii (Total Sulphur Content calculated as Sulphuric Anhydride (SO3) - Cl 7.3 of IS 4032:1985) |
- |
|
|
|
6 - Table - 1 ii (Magnesia - Cl 7.2 of IS 4032:1985) |
- |
|
|
|
6 - Table - 1 vi ( Alkali content as (Na2O + 0.658 K2O) - Cl 4.11 of IS 4032:1985) |
- |
|
|
|
7 -Table 2- vi (Drying Shrinkage- IS 4031 Part 10) |
- |
|
|
|
7 -Table 2- iv- c (Compressive Strength At 672 hrs ± 4 hr - IS 4031 Part 6) |
- |
|
|
|
7 -Table 2- iv- b (Compressive Strength At 168 hrs ± 2 hr - IS 4031 Part 6) |
- |
|
|
|
7 -Table 2- iv- a (Compressive Strength At 72 hrs ± 1 hr - IS 4031 Part 6) |
- |
|
|
|
7 -Table 2-iii- b (Setting Time Final- 4031 Part 5) |
- |
|
|
|
7 -Table 2- iii- a (Setting Time Initial- 4031 Part 5) |
- |
|
|
|
7 -Table 2- ii- b (Expansion by Autoclave- 4031 Part 3) |
- |
|
|
|
7 -Table 2- ii- a (Expansion by Le Chatelier- 4031 Part 3) |
- |
|
|
|
7 -Table 2- i (Fineness 4031 Part 2) |
- |
|
|
|
|
- |
- Excluding Table 1,Clause 6 ,sl. no.(vi) , alkali content; |