S.No. Lab Name Osl Code Indian Standard No. Product Grade / Type / Size / Designation etc. Testing Charges (Excl. Of Taxes) Validity Date Remark
10831 BIS, Central Laboratory (CL) None IS 14650 (1999) Carbon steel cast billet ingots, billets, blooms and slabs for re-rolling purposes - Specificaation - Rs. 450/- (only for dimensions and marking). View breakup
Rs. 450/- (only for dimensions and marking).
- -
Sample size shall be minimum dia> 3mm and thickness > 0.8 mm;
10832 BIS, Southern Regional Laboratory (SRL) None IS 1538 (1993) Cast iron fittings for pressure pipes for water, gas and sewage - Specification (Third Revision) - Rs 2700/- View breakup
-
- -
" 4 pcsx10cm + 2 nos " Excluding Excl. Tensile Test (Test Methord IS 2078:1979 Withdrawn) & hydraulic test,chemical tests
10833 BIS, Southern Regional Laboratory (SRL) None IS 1703 (2000) Water Fittings - Copper Alloy Float Valves (Horizontal Plunger Type) - - Rs. 4800/-and testing charges as per referred ISs View breakup
-
- -
" 1 No. Excluding Except hydraulic test, shutting off test and test for mechanical strength of lever, Thread Check,chemical tests
10834 BIS, Central Laboratory (CL) None IS 14491 (1997) Low carbon high strength cold rolled steel sheets and coils for cold forming - Specification - - View breakup
-
- -
Sample size shall be minimum dia> 3mm and thickness > 0.8 mm;
10835 BIS, Central Laboratory (CL) None IS 14331 (1995) Steels for high temperature bolting applications - Specification - - View breakup
-
- -
-
10836 BIS, Eastern Regional Laboratory (ERL) None IS 11169 : Part 1 (1984) Specification for steels for cold heading/cold extrusion applications: Part 1 wrought carbon and low alloy steels - - View breakup
-
- -
1.5 m (Prepared sample should be provided for hardenability test) Excluding Cl 12.1 Microscopic Inclusions, Cl 15 Decarburization, 14.1.1 Macroetch test, 14.1.3.1Eddy current/magnetic particle test ,Cl.7.1, C(<0.05%)V, Sn, B, Al
10837 BIS, Central Laboratory (CL) None IS 9968 : Part 1 (1988) Specification for elastomer insulatedcables: Part 1 for working voltages up to and including 1100 volts (First Revision) - Rs.12000/ View breakup
-
- -
Complete for finished Cable Except Water Absorption Test applicable for IE2 (Cl 21.1)
10838 BIS, Central Laboratory (CL) None IS 13114 (1991) forged brass gate, globe and check valves for water works purposes - Please see remarks View breakup
Rs. 3150/- + testing charges as per referred ISS (excluding Cl. 7.1.2, Cl. 8.1.2) (only visual tests for Stem).
- -
Excluding Complete for material as per table 1;
10839 BIS, Eastern Regional Laboratory (ERL) None IS 14885 (2001) Polyethylene pipes for the supply of gaseous fuels - Specification - Rs. 5500/- View breakup
Rs. 5500/- (excluding Hydraulic characteristics, Density, OIT, Resistance to weathering and squeeze-off)
- -
Facility not available for water content and Thermal stability, water content and thermal stability.
10840 BIS, Southern Regional Laboratory (SRL) None IS 1729 (2002) Cast iron/ductile iron drainage pipes and pipe fittings for over ground non-pressure pipeline socket and spigot series (Second Revision) - Rs. 2850/- and testing charges as per referred Iss View breakup
-
- -
" 1 full length pipe +1 piece for coating test " Excluding excl leakage test for fittings,Chemical tests
10841 BIS, Southern Regional Laboratory (SRL) None IS 1342 (2019) Oil pressure stoves - Specification (Seventh Revision) - - View breakup
-
- -
" 2 nos. Excluding Excl. thermal efficiency and threads,chemical tests
10842 BIS, Eastern Regional Laboratory (ERL) None IS 14887 (2014) Textiles – High density polyethylene (HDPE)/ polypropylene (PP) woven sacks for packaging of 50 kg food grains – Specification (first revision) - 19750 View breakup
Rs.19750/- (including all parameters), Rs.10450/- (excluding UV resistance test)
- -
Facility not available for UV resistance,
10843 BIS, Central Laboratory (CL) None IS 13983 (1994) Stainless Steel Sinks For Domestic Purposes - Rs.14635/- View breakup
-
- -
Material Grade/ designation as per relevant IS may please be declared. Sample dia > 3mm or thickness > 0.8 mm can only be tested; Excluding Complete for Material test only;
10844 BIS, Southern Regional Laboratory (SRL) None IS 3466 (1988) Specification For Masonry Cement - Please see remarks. View breakup
Rs. 7350/- excluding chemical tests.
- -
" 500 g Excluding Excl Air Content and Water retention test
10845 BIS, Northern Regional Laboratory (NRL) None IS 5950 (1984) Specification for shot firing cables (For Use Other Than In Shafts) (First Revision) - 11030 View breakup
Rs 11030/-
- -
-
10846 BIS, Southern Regional Laboratory (SRL) None IS 12600 (1989) Portland cement, low heat - specification - - View breakup
-
- -
" 8Kg+1kg Excluding Excl Heat of Hydration
10847 BIS, Central Laboratory (CL) None IS 7809 : Part 3 : Sec 1 (1986) Specification for pressure sensitive adhesive insulating tapes for electrical purposes: Part 3 requirements or individual materials: Sec 1 plasticized polyvinylchloride tapes with non - Thermosetting adhesive (First Revision) - - View breakup
-
- -
-
10848 BIS, Southern Regional Laboratory (SRL) None IS 12337 (1988) Specification for manually operated fertilizer broadcaster - Rs 600/- View breakup
-
- -
" 1 No.+ 15 kg of Fertilizer excluding chemical tests
10849 BIS, Central Laboratory (CL) None IS 374 (2019) Specification for electric ceiling type fans and regulators (Third Revision) - - View breakup
-
- -
Complete except BLDC Type Fan;
10850 BIS, Central Laboratory (CL) None IS 2745 (1983) Specification for non - Metal helmet for firemen and civil defence personnel (Second Revision) - 1500 View breakup
Rs.1500/- excluding shock absorption test, penetration resistance test, strength of retention system, water absorption test and firing test (Optional) and material testing charges as per relevant referred Iss
- -
Excluding Test facility not available for Cl 4.1 sizes, Cl 9.1 Shock Absorption Test, Cl 9.2 Penetration Resistance, Cl 9.3 Strenth of Retention system;
10851 BIS, Central Laboratory (CL) None IS 9562 (1980) Specification for non - Metal helmet for police force - Rs.2100/- View breakup
-
- -
Exclusion Test facility not available for Cl 4.1 sizes, Cl 9.1 Shock Absorption Test, Cl 9.2 Penetration Resistance, Cl 9.3 Strenth of Retention system, Cl 9. Firing Test, Cl 9.6 Flammability Test;
10852 BIS, Eastern Regional Laboratory (ERL) None IS 778 (1984) Specification for 2010 copper alloy gate, globe and check valves for waterworks purposes (Fourth Revision) For all classes except tests mentioned in remarks Rs 4500/- View breakup
-
- -
Facility not available for hydraulic test & Thread measurement
10853 BIS, Southern Regional Laboratory (SRL) None IS 8329 (2000) Centrifugally cast (Spun) ductile iron pressure pipes for water, gas and sewage - Specification (Third Revision) - Rs.7800/- View breakup
-
- -
" 1 No. Excluding Excl hydrostatic test, chemical facilty. Facility for preparation of test specimen not available.
10854 BIS, Central Laboratory (CL) None IS 2925 (1984) Specification for industrial safety helmets (Second Revision) - Rs 7770/- View breakup
-
- -
-
10855 BIS, Northern Regional Laboratory (NRL) None IS 2465 (1984) Specification for cables for motor vehicles (Second Revision) - Single core PVC Insulated Unsheathed: Rs. 11030/- View breakup
Single core PVC Insulated Unsheathed: Rs. 11030/- Single core PVC Insulated Sheathed: 75 % additional for sheath. Multi core with PVC Sheath: 75% additional for each additional core. Round and flat tinned copper braids without further covering for earthing: Rs. 1115/- Above charges are excluding Material tests, Ageing in oxygen bomb, Capacitance test, Ozone resistance test, Effect of heat on flexibility, Effect of oils, Effect of lubricating oil, brake fluid, diesel and petrol, Effect of cooling on flexibility.
- -
"Complete for general wiring only & Partial for PVC Insulation ignition cable Excluding Cl. 16 capacitance, Cl. 18 Effect of heat on flexibility"
10856 BIS, Central Laboratory (CL) None IS 4151 (1993.0) Protective helmets for motorcycle riders - Specification - testing charges for the product are Rs. 27300/- View breakup
-
- -
IS superseded by newer version;
10857 BIS, Southern Regional Laboratory (SRL) None IS 1038 (1983) Specification For Steel Doors, Windows And Ventilators - 3000 View breakup
-
- -
" 1+1 NO. Excluding Excl. micro and macro examination & Fillet weld test
10858 BIS, Southern Regional Laboratory (SRL) None IS 4308 (2019) Dry Chemical Powders for Fire Fighting — BC, ABC and D Types — Specification ( Third Revision ) - Rs 5770/- for both ordinary type & foam compatible type View breakup
-
- -
" 5 kg Excluding Rate of flow, Foam compatibility, Fire Test, Temperature Resistance Test , chemical constituents
10859 CENTRAL INSTITUTE OF PETROCHEMICALS ENGINEERING AND TECHNOLOGY (CIPET):CSTS-BHOPAL 8100534 IS 5175 (2014) Fibre ropes – Polypropylene split film, monofilament and multifilament (PP2) and polypropylene high- tenacity multifilament (PP3) – 3-, 4-, 8- and 12-strand ropes (third revision) - 6300 View breakup
-
31 Dec, 2026 -
-
10860 MSME TESTING CENTRE (WR), MUMBAI 7119404 IS 694 (2010) Polyvinyl chloride insulated unsheathed and sheathed cables/cords with rigid and flexible conductor for rated voltages up to and including 450/750 v (Fourth Revision) PVC insulated unsheathed & sheathed cables/cords 110V 22000 View breakup
Type test ₹12000 Singlecore/Unsheathed/01,₹16000 Singlecore/Sheathed/01,₹20000 Singlecore/Unsheathed/FR,₹22000 Singlecore/Sheathed/FR; Multicore: 25% extra for each additional core on single core rate, Cat.02 ₹5000/- extra
- -
-