| 1201 |
JBS TESTING SOLUTIONS PVT LTD (27), JALANDHAR
| 9164606
| IS 17632 (2022) |
General Purpose Chairs and Stools - Specification |
- |
57000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| CLAUSE 5(DIMENSIONS) |
- |
1500 |
|
- |
| CLAUSE 6(SURFACE PERFORMANCE) |
- |
6500 |
|
- |
| CLAUSE 6.2(Fabric and Leather (Synthetic and Natural) Performance) |
- |
12500 |
|
- |
| CLAUSE 7.2.1(Forwards Overbalancing and Sideways Overbalancing for Chairs without Arms) |
- |
1000 |
|
- |
| CLAUSE 7.2.2(Rearwards Overbalancing) |
- |
1000 |
|
- |
| CLAUSE 7.2.3(Sideways Overbalancing for Chairs with Arms) |
- |
1000 |
|
- |
| CLAUSE 7.2.4(Sideways Overbalancing for Chairs with Arms) |
- |
1000 |
|
- |
| CLAUSE 7.3.1.1(Seat static load test) |
- |
1800 |
|
- |
| CLAUSE 7.3.1.2(Back static load test) |
- |
1800 |
|
- |
| CLAUSE 7.3.1.3(Armrests/Wings sideways static load test) |
- |
1800 |
|
- |
| CLAUSE 7.3.1.4(Arm downwards static load test) |
- |
1800 |
|
- |
| CLAUSE 7.3.1.5(Leg forward static load test) |
- |
1800 |
|
- |
| CLAUSE 7.3.1.6(Leg sideways static load test) |
- |
1800 |
|
- |
| CLAUSE 7.3.1.7(Diagonal base load test) |
- |
1800 |
|
- |
| CLAUSE 7.3.1.8(Foot rest static-load test) |
- |
1800 |
|
- |
| CLAUSE 7.3.2.1(Seat impact test) |
- |
1800 |
|
- |
| CLAUSE 7.3.2.2(Back impact test) |
- |
1800 |
|
- |
| CLAUSE 7.3.2.3(Arm impact test) |
- |
1800 |
|
- |
| CLAUSE 7.3.2.4(Drop test) |
- |
1800 |
|
- |
| CLAUSE 7.4.1(Seat Fatigue Test) |
- |
12500 |
|
- |
| CLAUSE 7.4.2(Back Fatigue Test) |
- |
19000 |
|
- |
| CLAUSE 7.4.3(Arm Rest Durability Test) |
- |
13000 |
|
- |
| Cl - 5(DIMENSIONS) |
- |
1500 |
|
- |
| Cl-6.1 (a)(Resistance to mechanical damage) |
- |
1000 |
|
- |
| Cl-6.1 (b)(Pencil hardness) |
- |
1000 |
|
- |
| Cl-6.1 (c)(Resistance to wet heat) |
- |
1500 |
|
- |
| Cl-6.1 (d)(Resistance to dry heat) |
- |
1500 |
|
- |
| Cl-6.1 (e)(Resistance to marking by cold liquids) |
- |
1000 |
|
- |
| Cl-6.1 (f)(Resistance to marking by cold oils and fats) |
- |
1000 |
|
- |
| Cl-6.1 (g)(Adhesive performance) |
- |
1500 |
|
- |
| Cl-6.2 (a) 1(Breaking load) |
- |
1000 |
|
- |
| Cl-6.2 (a) 2(Elongation at break) |
- |
1000 |
|
- |
| Cl-6.2 (a) 3(Tear strength) |
- |
1000 |
|
- |
| Cl-6.2 (a) 4(Colour fastness to light) |
- |
1500 |
|
- |
| Cl-6.2 (a) 5(Colour fastness to rubbing) |
- |
1000 |
|
- |
| Cl-6.2 (a) 6(Colour fastness to perspiration) |
- |
1000 |
|
- |
| Cl-6.2 (a) 7(Colour fastness to water) |
- |
1000 |
|
- |
| Cl-6.2 (a) 8(Pilling resistance) |
- |
1000 |
|
- |
| Cl-6.2 (a) 9(Coating adhesion strength) |
- |
1000 |
|
- |
| Cl-6.2 (a) 10(Seam slippage) |
- |
1000 |
|
- |
| Cl-6.2 (a) 11(Resistance to damage by flexing) |
- |
1000 |
|
- |
| Cl-6.2 (a) 12(Abrasion resistance) |
- |
1000 |
|
- |
| Cl-6.2 (a) 13(Bursting strength) |
- |
1000 |
|
- |
| Cl-6.2 (a) 14(Resistance to cold) |
- |
1000 |
|
- |
| Cl-6.2 (b) 1(Tear strength) |
- |
1000 |
|
- |
| Cl-6.2 (b) 2(Flexing endurance) |
- |
1000 |
|
- |
| Cl-6.2 (b) 3(Finish adhesion) |
- |
1000 |
|
- |
| Cl-6.2 (b) 4(Colour fastness to artificial light) |
- |
1000 |
|
- |
| Cl-6.2 (b) 5(Colour fastness to rubbing) |
- |
1000 |
|
- |
| Cl-6.2 (b) 6(Colour fastness to water spotting) |
- |
1000 |
|
- |
| Cl-6.2 (b) 7(Water vapour permeability) |
- |
1000 |
|
- |
| Cl-6.2 (b) 8(Colour fastness to water) |
- |
1000 |
|
- |
| Cl-7.2.1(Forwards Overbalancing and Sideways Overbalancing for Chairs without Arms) |
- |
0 |
|
- |
| Cl-7.2.2(Rearwards Overbalancing) |
- |
0 |
|
- |
| Cl-7.2.3(Sideways Overbalancing for Chairs with Arms) |
- |
0 |
|
- |
| Cl-7.2.4(Stools/ Poufs (All Directions)) |
- |
0 |
|
- |
| Cl-7.3.1(Static Load Test) |
- |
0 |
|
- |
| Cl-7.3.2(Impact Test) |
- |
0 |
|
- |
| Cl-7.4.1(Seat Fatigue Test) |
- |
0 |
|
- |
| Cl-7.4.2(Back Fatigue Test) |
- |
0 |
|
- |
| Cl-7.4.3(Arm Rest Durability) |
- |
0 |
|
- |
| Cl-9(Marking) |
- |
0 |
|
- |
| 7.1(General test conditions) |
- |
0 |
|
- |
|
- |
- - |
| 1202 |
EKO PRO ENGINEERS PRIVATE LIMITED (32/41), GHAZIABAD
| 9179706
| IS 12254 (2021) |
POLYVINYLCHLORIDE PVC INDUSTRIAL BOOTS - SPECIFICATION Second Revision |
ALL |
43500 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 5.2(Size) |
- |
43500 |
|
- |
| 5.3(Height) |
- |
43500 |
|
- |
| 5.4.4(Slip resistance) |
- |
43500 |
|
- |
| 5.4.5(Leak proofness) |
- |
43500 |
|
- |
| 5.4.6.1(Toe caps General) |
- |
43500 |
|
- |
| 5.4.6.2(Internal length of toecaps) |
- |
43500 |
|
- |
| 5.4.6.3(Corrosion resistance) |
- |
43500 |
|
- |
| 5.4.6.4(Impact resistance) |
- |
43500 |
|
- |
| 5.4.6.5(Compression resistance) |
- |
43500 |
|
- |
| 5.4.7(Colour) |
- |
43500 |
|
- |
| 5.5.1(Upper material) |
- |
43500 |
|
- |
| 5.5.1(Upper Thickness) |
- |
43500 |
|
- |
| 5.5.2(Upper tensile strength) |
- |
43500 |
|
- |
| 5.5.3(Upper flexing) |
- |
43500 |
|
- |
| 5.5.4(Upper Hardness) |
- |
43500 |
|
- |
| 5.6.1(Lining material) |
- |
43500 |
|
- |
| 5.6.2(Lining Tear strength) |
- |
43500 |
|
- |
| 5.6.3(Lining abrasion) |
- |
43500 |
|
- |
| 5.6.4(Lining adhesion with upper) |
- |
43500 |
|
- |
| 5.7.1(Insole material) |
- |
43500 |
|
- |
| 5.7.1(Insole thickness) |
- |
43500 |
|
- |
| 5.7.2(Insole abrasion) |
- |
43500 |
|
- |
| 5.7.3(Water absorption and desorption) |
- |
43500 |
|
- |
| 5.8.2(Eyelets material) |
- |
43500 |
|
- |
| 5.8.2(Lace material) |
- |
43500 |
|
- |
| 5.8.2(Lace length) |
- |
43500 |
|
- |
| 5.8.2(Lace breaking load) |
- |
43500 |
|
- |
| 5.9.1(Insock material) |
- |
43500 |
|
- |
| 5.9.2(Inscok abrasion resistance) |
- |
43500 |
|
- |
| 5.9.3(Insock water absorption and desorption) |
- |
43500 |
|
- |
| 5.8.2(Closing thread breaking load) |
- |
43500 |
|
- |
| 5.11.1(Outsole material) |
- |
43500 |
|
- |
| 5.11.1(Outsole thickness) |
- |
43500 |
|
- |
| 5.11.2(Outsole density) |
- |
43500 |
|
- |
| 5.11.3(Outsole Interlayer bond) |
- |
43500 |
|
- |
| 5.11.4(Outsole tear) |
- |
43500 |
|
- |
| 5.11.5(Outsole Abrasion) |
- |
43500 |
|
- |
| 5.11.6(Outsole hardness) |
- |
43500 |
|
- |
| 5.11.7(Outsole flexing) |
- |
43500 |
|
- |
| 5.4.2(Ergonomic feature) |
- |
43500 |
|
- |
| 5.4.3(Sole bond) |
- |
43500 |
|
- |
| 5.4.8.1(Conductive Footwear) |
- |
43500 |
|
- |
| 5.4.8.2(Antistatic Footwear) |
- |
43500 |
|
- |
| 5.4.8.3.2(Penetration resistance) |
- |
43500 |
|
- |
| 5.4.8.4(Cut resistance) |
- |
43500 |
|
- |
| 5.5.5(Upper Cold flex resistance) |
- |
0 |
|
- |
| 5.4.8.6(Outsole resistance to fuel oil) |
- |
43500 |
|
- |
| 5.11.8(Outsole cold flex resistance) |
- |
43500 |
|
- |
| 6.1(Volatility) |
- |
43500 |
|
- |
| 5.4.8.5(Outsole resistance to acid and alkali) |
- |
43500 |
|
- |
| 6.2(Lead content) |
- |
43500 |
|
- |
| Table 1 as per IS 17011 2018(pH) |
- |
43500 |
|
- |
| Table 1 as per IS 17011 2018(Phthalates (each individual phthalate)) |
- |
43500 |
|
- |
| Table 1 as per IS 17011 2018(Nickel, on skin contact) |
- |
43500 |
|
- |
| Table 1 as per IS 17011 2018(Allergenic and carcinogenic disperse dyes) |
- |
43500 |
|
- |
| Table 1 as per IS 17011 2018(Aromatic amines released from Azo dyes (each individual amine)) |
- |
43500 |
|
- |
| Table 1 as per IS 17011 2018(Aromatic amines released from Azo dyes (each individual amine)) |
- |
43500 |
|
- |
| Table 1 as per IS 17011 2018(Chromium (VI)) |
- |
43500 |
|
- |
| Table 1 as per IS 17011 2018(Dimethyl fumarate (DMFU)) |
- |
43500 |
|
- |
| Table 1 as per IS 17011 2018(Formaldehyde (free or released by partial hydrolysis)) |
- |
43500 |
|
- |
| Table 1 as per IS 17011 2018(Formaldehyde) |
- |
43500 |
|
- |
| Table 1 as per IS 17011 2018(Organotin compounds) |
- |
43500 |
|
- |
| Table 1 as per IS 17011 2018(PCP-TeCP-TriCP polychlorophenols) |
- |
43500 |
|
- |
| 5.10(Closing Thread (If used)) |
- |
43500 |
|
- |
| Cl.6.2(Lead Content-IS 12240 (Part 5),) |
- |
43500 |
|
- |
| Cl.6.1(Volatility- IS 12240 (Part 4)) |
- |
43500 |
|
- |
|
- |
- - |
| 1203 |
Atckon Laboratories LLP, Bahadurgarh
| 8186436
| IS 18507 (2024) |
Drywall Screws � Specification |
ALL SIZES |
18500 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Clause. 4.0(Dimenssions.) |
- |
3000 |
|
- |
| Clause. 4.0(Thread size.) |
- |
3000 |
|
- |
| Clause. 4.0(Length) |
- |
3000 |
|
- |
| Clause. 5.0(Material) |
- |
7500 |
|
- |
| Clause. 5.0(Cross Recess) |
- |
7500 |
|
- |
| Clause. 5.0(Tolerances) |
- |
7500 |
|
- |
| Clause. 5.0(Surface Condition) |
- |
7500 |
|
- |
| Clause. 5.0(Surface Coating) |
- |
7500 |
|
- |
| Clause. 5.0(Acceptability) |
- |
7500 |
|
- |
| Clause.6.0(Torque Testing) |
- |
3000 |
|
- |
| Clause.7.0(Hardness) |
- |
3000 |
|
- |
| Clause.8.0(Designation) |
- |
1000 |
|
- |
| Clause.9.0(Marking) |
- |
1000 |
|
- |
|
- |
- Included w.e.f. 16.03.2026 |
| 1204 |
WELL TECH TEST AND RESEARCH CENTER, DERABASSI
| 9177306
| IS 3829 : Part 3 (1985) |
Specification for steam sterilizers: Part 3 pressure sterilizers, vertical cylindrical type |
DESIGN AS PER CL 3 , SHAPE AND SIZE AS PER CL 4 |
11304 View breakup
The testing charges quoted by the laboratory exceed 1.5 times the government-approved rate. Therefore, in accordance with LRS 2020, the testing charges are being capped at 1.5 times the BIS lab.
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4.1(Shape) |
- |
1000 |
|
- |
| 4.2(Size) |
- |
500 |
|
- |
| 5.1(Carbon- Relevant parts of IS 228 or any other established instrumental/Chemicall method) |
- |
200 |
|
- |
| 5.1(Silicon- Relevant parts of IS 228 or any other established instrumental/Chemicall method) |
- |
200 |
|
- |
| 5.1(Manganese- Relevant parts of IS 228 or any other established instrumental/Chemicall method) |
- |
200 |
|
- |
| 5.1(Nickel- Relevant parts of IS 228 or any other established instrumental/Chemicall method) |
- |
200 |
|
- |
| 5.1(Chromium- Relevant parts of IS 228 or any other established instrumental/Chemicall method) |
- |
200 |
|
- |
| 5.1(Sulphur- Relevant parts of IS 228 or any other established instrumental/Chemicall method) |
- |
200 |
|
- |
| 5.1(Phosphorous- Relevant parts of IS 228 or any other established instrumental/Chemicall method) |
- |
200 |
|
- |
| 5.1(Nitrogen- Relevant parts of IS 228 or any other established instrumental/Chemicall method) |
- |
200 |
|
- |
| 5.1(Titanium- Relevant parts of IS 228 or any other established instrumental/Chemicall method) |
- |
200 |
|
- |
| 5.1(Niobium- Relevant parts of IS 228 or any other established instrumental/Chemicall method) |
- |
250 |
|
- |
| 5.1(Molybdenum- Relevant parts of IS 228 or any other established instrumental/Chemicall method) |
- |
200 |
|
- |
| 5.1(Copper- Relevant parts of IS 228 or any other established instrumental/Chemicall method) |
- |
200 |
|
- |
| 5.1(As per IS 306 or IS 318- Relevant parts of IS 4027 or any other established instrumental/Chemicall method) |
- |
2500 |
|
- |
| 5.1(As per IS 513- Relevant parts of IS 228 or any other established instrumental/Chemicall method) |
- |
2000 |
|
- |
| 5.1(As per IS 737- Relevant parts of IS 504 or any other established instrumental/Chemicall method) |
- |
2000 |
|
- |
| 6.1(as per Cl. 6.1) |
- |
500 |
|
- |
| 6.1.2(Shell) |
- |
500 |
|
- |
| 6.1.3(as per Cl. 6.1.3) |
- |
500 |
|
- |
| 6.2(Lid) |
- |
1000 |
|
- |
| 6.3(Lid Gasket) |
- |
1000 |
|
- |
| 7.1.2(Safety Valve- Cl. 7.1.2) |
- |
1000 |
|
- |
| 7.1.3(as per Cl. 7.1.3) |
- |
2000 |
|
- |
| 7.1.4(as per Cl. 7.1.4) |
- |
2000 |
|
- |
| 8.1(Hydrostatic Test- as per Cl 8.1.1) |
- |
5000 |
|
- |
| 3(Design) |
- |
500 |
|
- |
| 4(Shape & Size) |
- |
2000 |
|
- |
| 5(Materials) |
- |
2000 |
|
- |
| 6(Construction) |
- |
2500 |
|
- |
| 7(Fittings) |
- |
2500 |
|
- |
| 8(Hydrostatic test) |
- |
0 |
|
REPEAT |
| 8(Methods of steam supply to sterilizer) |
- |
5000 |
|
- |
| 9.1(Safety Requirements) |
- |
10000 |
|
- |
| 9.1(Power Supply &Input) |
- |
5000 |
|
- |
| 9.1("Leakage Current and Electric Strength
at operating temperature") |
- |
5000 |
|
- |
| 9.1(Provision for Earthing) |
- |
5000 |
|
- |
| 9.1(Creepage Distance and Clearance) |
- |
5000 |
|
- |
| 10(Accessories) |
- |
1000 |
|
- |
| 10(Marking) |
- |
1000 |
|
- |
| 13(Packing) |
- |
1000 |
|
- |
| 4.1(Shape) |
- |
0 |
|
- |
| 4.2(Size) |
- |
0 |
|
- |
| 5.1(Carbon- Relevant parts of IS 228 or any other established instrumental/Chemicall method) |
- |
0 |
|
- |
| 5.1(Silicon- Relevant parts of IS 228 or any other established instrumental/Chemicall method) |
- |
0 |
|
- |
| 5.1(Manganese- Relevant parts of IS 228 or any other established instrumental/Chemicall method) |
- |
0 |
|
- |
| 5.1(Nickel- Relevant parts of IS 228 or any other established instrumental/Chemicall method) |
- |
0 |
|
- |
| 5.1(Chromium- Relevant parts of IS 228 or any other established instrumental/Chemicall method) |
- |
0 |
|
- |
| 5.1(Sulphur- Relevant parts of IS 228 or any other established instrumental/Chemicall method) |
- |
0 |
|
- |
| 5.1(Phosphorous- Relevant parts of IS 228 or any other established instrumental/Chemicall method) |
- |
0 |
|
- |
| 5.1(Nitrogen- Relevant parts of IS 228 or any other established instrumental/Chemicall method) |
- |
0 |
|
- |
| 5.1(Titanium- Relevant parts of IS 228 or any other established instrumental/Chemicall method) |
- |
0 |
|
- |
| 5.1(Niobium- Relevant parts of IS 228 or any other established instrumental/Chemicall method) |
- |
0 |
|
- |
| 5.1(Molybdenum- Relevant parts of IS 228 or any other established instrumental/Chemicall method) |
- |
0 |
|
- |
| 5.1(Copper- Relevant parts of IS 228 or any other established instrumental/Chemicall method) |
- |
0 |
|
- |
| 5.1(As per IS 306 or IS 318- Relevant parts of IS 4027 or any other established instrumental/Chemicall method) |
- |
0 |
|
- |
| 5.1(As per IS 513- Relevant parts of IS 228 or any other established instrumental/Chemicall method) |
- |
0 |
|
- |
| 5.1(As per IS 737- Relevant parts of IS 504 or any other established instrumental/Chemicall method) |
- |
0 |
|
- |
| 6.1(as per Cl. 6.1) |
- |
0 |
|
- |
| 6.1.2(Shell) |
- |
0 |
|
- |
| 6.1.3(as per Cl. 6.1.3) |
- |
0 |
|
- |
| 6.2(Lid) |
- |
0 |
|
- |
| 6.3(Lid Gasket) |
- |
0 |
|
- |
| 7.1.2(Safety Valve- Cl. 7.1.2) |
- |
0 |
|
- |
| 7.1.3(as per Cl. 7.1.3) |
- |
0 |
|
- |
| 7.1.4(as per Cl. 7.1.4) |
- |
0 |
|
- |
| 8.1(Hydrostatic Test- as per Cl 8.1.1) |
- |
0 |
|
- |
| 3(Design) |
- |
0 |
|
- |
| 4(Shape & Size) |
- |
0 |
|
- |
| 5(Materials) |
- |
0 |
|
- |
| 6(Construction) |
- |
0 |
|
- |
| 7(Fittings) |
- |
0 |
|
- |
| 8(Hydrostatic test) |
- |
0 |
|
- |
| 8(Methods of steam supply to sterilizer) |
- |
0 |
|
- |
| 9.1(Safety Requirements) |
- |
0 |
|
- |
| 9.1(Power Supply &Input) |
- |
0 |
|
- |
| 9.1("Leakage Current and Electric Strength
at operating temperature") |
- |
0 |
|
- |
| 9.1(Provision for Earthing) |
- |
0 |
|
- |
| 9.1(Creepage Distance and Clearance) |
- |
0 |
|
- |
| 10(Accessories) |
- |
0 |
|
- |
| 10(Marking) |
- |
0 |
|
- |
| 13(Packing) |
- |
0 |
|
- |
|
30 Mar, 2027 |
- - |
| 1205 |
LPG Equipment Research Centre (LERC), Bengaluru
| 6141034
| IS 2347 (2023) |
DOMESTIC PRESSURE COOKER � SPECIFICATION |
- |
26000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4.1(Gross capacity) |
- |
26000 |
|
- |
| 4.2(Body Capacity) |
- |
26000 |
|
- |
| 5.1(Body, Lid, Containers and Grid) |
- |
26000 |
|
- |
| 5.1.2(Body and Lid ) |
- |
26000 |
|
- |
| 5.1.3(Stainless steel pressure cooker) |
- |
26000 |
|
- |
| 5.1.4(Aluminium cooker ) |
- |
26000 |
|
- |
| 5.2(Safety Relief Device) |
- |
26000 |
|
- |
| 5.3(Gasket) |
- |
26000 |
|
- |
| 5.4(Handles and Knobs) |
- |
26000 |
|
- |
| 5.5(Pressure Regulating Device ) |
- |
26000 |
|
- |
| 5.6(Vent Seal Pin for Pressure Regulating Device ) |
- |
26000 |
|
- |
| 5.7(Vent Pipe ) |
- |
26000 |
|
- |
| 5.8(Vent Pipe Nut ) |
- |
26000 |
|
- |
| 5.9(Spring ) |
- |
26000 |
|
- |
| 5.1(Material of Rim ) |
- |
26000 |
|
- |
| 5.11(Visual Pressure Indicator) |
- |
26000 |
|
- |
| 5.12(Gasket Release System) |
- |
26000 |
|
- |
| 6(Construction) |
- |
26000 |
|
- |
| 7(Workmanship and Finish ) |
- |
26000 |
|
- |
| 8.1(Air Pressure Test ) |
- |
26000 |
|
- |
| 8.2(Proof Pressure Test ) |
- |
26000 |
|
- |
| 8.3(Operating Test for Pressure Regulating Device ) |
- |
26000 |
|
- |
| 8.4(Test for Safety Relief Device ) |
- |
26000 |
|
- |
| 8.5(Bursting Pressure Test ) |
- |
26000 |
|
- |
| 8.6(Test for Removal of Lid under Pressure ) |
- |
26000 |
|
- |
| 8.7(Test for Spring Loaded Mechanism ) |
- |
26000 |
|
- |
| 8.8(Composite Cooker Base ) |
- |
26000 |
|
- |
| 8.9(Aluminium induction compatible Base ) |
- |
26000 |
|
- |
| 8.1(Handles of cooker ) |
- |
26000 |
|
- |
| 8.11(External Coating) |
- |
26000 |
|
- |
| 8.12(Internal Coating ) |
- |
26000 |
|
- |
| 8.13(Integral electrical heating) |
- |
26000 |
|
- |
| 8.14(Ply construction cooker Body ) |
- |
26000 |
|
- |
| 8.15.1(Fragmentation Test ) |
- |
26000 |
|
- |
| 8.15.2(Ball Drop Test ) |
- |
26000 |
|
- |
| 8.15.3(Thermal Shock Test ) |
- |
26000 |
|
- |
| 8.15.4(Free Fall Test) |
- |
26000 |
|
- |
| 8.17(Test for Effectiveness for Induction Bottom) |
- |
26000 |
|
- |
| 11(Marking ) |
- |
26000 |
|
- |
| 12(Packing ) |
- |
26000 |
|
- |
| 4(Capacity) |
- |
26000 |
|
- |
| 4.2(Body Capacity) |
- |
26000 |
|
- |
| 5.1.1(Body, Lid, Containers and Grid) |
- |
26000 |
|
- |
| 5.1.2(Body, Lid, Containers and Grid) |
- |
26000 |
|
- |
| 5.1.3(Body, Lid, Containers and Grid) |
- |
26000 |
|
- |
| 5.1.4(Body, Lid, Containers and Grid) |
- |
26000 |
|
- |
| 5.1.5(Body, Lid, Containers and Grid) |
- |
26000 |
|
- |
| 5.2.1(Destructive Type Safety Relief Device) |
- |
26000 |
|
- |
| 5.2.2(Resettable Type Safety Relief Device) |
- |
26000 |
|
- |
| 5.3(Gasket) |
- |
26000 |
|
- |
| 5.4(Handles and Knobs) |
- |
26000 |
|
- |
| 5.5(Pressure Regulating Device) |
- |
26000 |
|
- |
| 5.6(Vent Seal Pin for Pressure Regulating Device) |
- |
26000 |
|
- |
| 5.7(Vent Pipe) |
- |
26000 |
|
- |
| 5.8(Vent Pipe Nut) |
- |
26000 |
|
- |
| 5.9(Spring) |
- |
26000 |
|
- |
| 5.10(Spring) |
- |
26000 |
|
- |
| 5.11(Visual Pressure Indicator) |
- |
26000 |
|
- |
| 5.12(Gasket Release System) |
- |
26000 |
|
- |
| 6(CONSTRUCTION) |
- |
26000 |
|
- |
| 6.1(Pressure Regulating Device) |
- |
26000 |
|
- |
| 6.1.1(Pressure Regulating Device) |
- |
26000 |
|
- |
| 6.1.1(Minimum Inside diameter of Vent Pipe.) |
- |
26000 |
|
- |
| 6.1.2(Pressure Regulating Device) |
- |
26000 |
|
- |
| 6.1.3(Pressure Regulating Device) |
- |
26000 |
|
- |
| 6.1.4(Pressure Regulating Device) |
- |
26000 |
|
- |
| 6.1.5(Pressure Regulating Device) |
- |
26000 |
|
- |
| 6.1.6(Pressure Regulating Device) |
- |
26000 |
|
- |
| 6.2(Safety Relief Device) |
- |
26000 |
|
- |
| 6.2.1(Safety Relief Device) |
- |
26000 |
|
- |
| 6.2.2(Safety Relief Device) |
- |
26000 |
|
- |
| 6.2.3(Safety Relief Device) |
- |
26000 |
|
- |
| 6.3.1(Temperature Responsive Safety Relief Device) |
- |
26000 |
|
- |
| 6.3.2(Temperature Responsive Safety Relief Device) |
- |
26000 |
|
- |
| 6.3.3(Temperature Responsive Safety Relief Device) |
- |
26000 |
|
- |
| 6.4.1(Handles and Knobs) |
- |
26000 |
|
- |
| 6.4.1.1(Handles and Knobs) |
- |
26000 |
|
- |
| 6.4.2(Handles and Knobs) |
- |
26000 |
|
- |
| 6.4.2.1(Handles and Knobs) |
- |
26000 |
|
- |
| 6.5(CONSTRUCTION) |
- |
26000 |
|
- |
| 6.6(CONSTRUCTION) |
- |
26000 |
|
- |
| 6.7(Internal Level Marking) |
- |
26000 |
|
- |
| 6.8(Internal Level Marking) |
- |
26000 |
|
- |
| 7.1(WORKMANSHIP AND FINISH) |
- |
26000 |
|
- |
| 7.2(WORKMANSHIP AND FINISH) |
- |
26000 |
|
- |
| 8.17(Test for Effectiveness for Induction Bottom) |
- |
26000 |
|
- |
| 8.16(PRD with chain) |
- |
26000 |
|
- |
| 8.15.4.2(Glass lid without rim) |
- |
26000 |
|
- |
| 8.15.4.1("Free Fall Test ( Glass lid with rim)
") |
- |
26000 |
|
- |
| 8.15.3(Thermal Shock Test on Tempered Glass lid) |
- |
26000 |
|
- |
| 8.15.2(Ball Drop Test on Tempered Glass lid) |
- |
26000 |
|
- |
| 8.15.1(Fragmentation Test on Tempered Glass lid) |
- |
26000 |
|
- |
| 8.14(3 ply construction cooker body) |
- |
26000 |
|
- |
| 8.13(Pressure cooker with integral electrical heating) |
- |
26000 |
|
- |
| 8.12(Internal Coating) |
- |
26000 |
|
- |
| 7.3(WORKMANSHIP AND FINISH) |
- |
26000 |
|
- |
| 7.4(WORKMANSHIP AND FINISH) |
- |
26000 |
|
- |
| 8.1(Air Pressure Test) |
- |
26000 |
|
- |
| 8.2(Proof Pressure Test) |
- |
26000 |
|
- |
| 8.3.1(Operating Test for Pressure Regulating Device) |
- |
26000 |
|
- |
| 8.4.1(Test for Safety Relief Device) |
- |
26000 |
|
- |
| 8.4.2(Test for Safety Relief Device) |
- |
26000 |
|
- |
| 8.4.2 NOTE(Test for Safety Relief Device) |
- |
26000 |
|
- |
| 8.5(Bursting Pressure Test) |
- |
26000 |
|
- |
| 8.6.1(Tests for Removal of Lid under Pressure For Outer Lid Cooker) |
- |
26000 |
|
- |
| 8.6.2(Tests for Removal of Lid under Pressure For inner Lid Cooker) |
- |
26000 |
|
- |
| 8.6.3(Tests for Removal of Lid under Pressure: For Cooker Fastened by Screw Clamps or Any Other Locking Device) |
- |
26000 |
|
- |
| 8.6.4(Tests for Removal of Lid under Pressure in case of electrical pressure cooker) |
- |
26000 |
|
- |
| 8.7(Test for Spring Loaded Mechanism) |
- |
26000 |
|
- |
| 8.8(Test for stainless steel cookers) |
- |
26000 |
|
- |
| 8.9("For stainless steel, aluminium induction
compatible base and 3 ply cooker") |
- |
26000 |
|
- |
| 8.10(Testing of Handles of the cooker) |
- |
26000 |
|
- |
| 8.10 Note 3(Testing of Handles of the cooker) |
- |
26000 |
|
- |
| 8.10 Note 4(Testing of Handles of the cooker) |
- |
26000 |
|
- |
| 8.10 Note 5(Testing of Handles of the cooker) |
- |
26000 |
|
- |
| 8.10 Note 6(Testing of Handles of the cooker) |
- |
26000 |
|
- |
| 8.10.1(Testing of Handles of the cooker) |
- |
26000 |
|
- |
| 8.11.1(External Coating) |
- |
26000 |
|
- |
| Cl 18.15.5 (Amendment No.2)(Nominal thickness of glass lid) |
- |
26000 |
|
- |
|
- |
- Included w.e.f. 06.08.2026 |
| 1206 |
JBS TESTING SOLUTIONS PVT LTD (27), JALANDHAR
| 9164606
| IS 636 (2018) |
Non - Percolating flexible fire fighting delivery hose - Specification (Fourth Revision) |
- |
62500 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl 6.1.1(Inner lining shall be of rubber or rubberized fabric lining which is generally smooth and practically free
from pitting and other imperfections) |
- |
0 |
|
Type 1 Rs 44,500/- Type 2 Rs 47,000/- Type 3 Rs 62,500/- |
| Cl 6.1.2(Externally applied elastomeric coating or
covering of the reinforcement, if present shall be
generally smooth and practically free from pitting and
other imperfections) |
- |
0 |
|
Type 1 Rs 44,500/- Type 2 Rs 47,000/- Type 3 Rs 62,500/- |
| Cl 6.1.3(The jacket shall be practically free from dirt, knots,
lumps, irregularities of the yarn and other visible defects.) |
- |
500 |
|
Type 1 Rs 44,500/- Type 2 Rs 47,000/- Type 3 Rs 62,500/- |
| Cl.6.2(The internal diameter of the hose shall be measured by
a suitable conical plug gauge and shall conform to the
specified diameter with a tolerance of plus 2 and minus
0.0 mm.) |
- |
500 |
|
Type 1 Rs 44,500/- Type 2 Rs 47,000/- Type 3 Rs 62,500/- |
| Cl.6.3(Unless specified otherwise, the standard length shall
be 30 m. Unless otherwise specified, a tolerance of ± 2
percent shall be permitted on the length prescribed for
the hose by the purchaser but the total of all lengths of
hose supplied shall be not less than the total quantity
specified by the purchaser.) |
- |
500 |
|
Type 1 Rs 44,500/- Type 2 Rs 47,000/- Type 3 Rs 62,500/- |
| Cl.6.4(The average mass of hose per meter of 2 m length,
without couplings attached, shall not be more than that
prescribed in Table 1. For the determination of mass,
sample of the hose shall be conditioned at 27 ± 2°C and
65 ± 5 percent relative humidity for a period of at least
48 h and then shall be weighed under the same conditions.) |
- |
500 |
|
Type 1 Rs 44,500/- Type 2 Rs 47,000/- Type 3 Rs 62,500/- |
| Cl.6.5(For 30 m length of dry hose without couplings, the coil
diameter shall not exceed 45 cm for Type 1, 50 cm for
Type 2 and 55 cm for Type 3.) |
- |
500 |
|
Type 1 Rs 44,500/- Type 2 Rs 47,000/- Type 3 Rs 62,500/- |
| Cl.6.6(Each hose length shall be subjected to an internal hydraulic pressure of 23 kgf/cm² in accordance with 8.1 of IS 443
(Part 3) increasing the pressure at the rate not exceeding
10 kgf/cm² per min and maintaining it for 1 min. Within
this 1 min, the hose shall neither develop any leakage or
sweating, nor shall any thread in the jacket break.) |
- |
2500 |
|
Type 1 Rs 44,500/- Type 2 Rs 47,000/- Type 3 Rs 62,500/- |
| Cl.6.7(A test length of hose, 1 m clear of fittings when
subjected to an internal hydraulic pressure in
accordance with 8.3 of IS 443 (Part 3) while increasing
the pressure at the rate not exceeding 10 kgf/cm2 per
min shall not burst or show leakage before a pressure
of 38 kgf/cm2 is reached) |
- |
2500 |
|
Type 1 Rs 44,500/- Type 2 Rs 47,000/- Type 3 Rs 62,500/- |
| Cl.6.8(There shall be no sign of leakage or rupture and no thread in the jacket shall break after retaining the internal hydraulic pressure of 23 kgf/cm2 for 30 seconds.) |
- |
1000 |
|
Type 1 Rs 44,500/- Type 2 Rs 47,000/- Type 3 Rs 62,500/- |
| Cl.6.9(The increase in length shall not exceed 6 percent at an internal hydraulic pressure of 10 kgf/cm2 for 2 minutes.) |
- |
1000 |
|
Type 1 Rs 44,500/- Type 2 Rs 47,000/- Type 3 Rs 62,500/- |
| Cl.6.10(The increase in diameter shall not be more than 10% at an internal hydraulic pressure of 10 kgf/cm2 for 2 minutes.) |
- |
1000 |
|
- |
| Cl 6.11 (Adhesion (Cl. 6.11.1))(Rate of separation shall not exceed 25 mm/min 1) Cover) |
- |
500 |
|
- |
| Cl 6.11 (Adhesion (Cl. 6.11.1))(Rate of separation shall not exceed 25 mm/min 2) Jet) |
- |
500 |
|
- |
| Cl.6.11 Acccleraled Ageing Test (Cl. 6.11.2) - 1)(After ageing, there shall be no tackiness on the surface of lining or the surface of the cover. ) |
- |
2000 |
|
- |
| Cl.6.11 Acccleraled Ageing Test (Cl. 6.11.2) - 2)(shall meet the requirements. given in Cl.6.7 (A test length of hose, 1 m clear of fittings when
subjected to an internal hydraulic pressure in
accordance with 8.3 of IS 443 (Part 3) while increasing
the pressure at the rate not exceeding 10 kgf/cm2 per
min shall not burst or show leakage before a pressure
of 38 kgf/cm2 is reached)) |
- |
2500 |
|
- |
| Cl.6.11 Acccleraled Ageing Test (Cl. 6.11.2) - 3)(Rate of separation shall not exceed 25 mm/min 1) Cover) |
- |
500 |
|
- |
| Cl.6.11 Acccleraled Ageing Test (Cl. 6.11.2) - 3)(Rate of separation shall not exceed 25 mm/min 2) Jet) |
- |
500 |
|
- |
| Cl.6.12(When determined by the method described in Annex C,
the average number of cycles completed before bursting
of three test pieces, shall not be less than the value
specified in Table 2.) |
- |
2000 |
|
- |
| Cl.6.13(When tested in accordance with Annex D, the amount
of moisture absorbed shall not exceed 0.20 kg/m2 for
Type 2 hoses and 0.02 kg/m2 for Type 3 hoses.) |
- |
1000 |
|
- |
| Cl.6.14(When tested by the method described in Annex E, none
of the test samples shall burst at less than 8 s of the
application of the hot cube for Type 2 and 20 s for
Type 3 hose.) |
- |
1500 |
|
- |
| Cl.6.15 (1)(The length shall be laid horizontally and
the central fully immersed portion of the hose shall be
visually examined for any swelling of rubber,
weathering and cracking in the rubber lining) |
- |
2000 |
|
- |
| Cl.6.15 (2)(Rate of separation shall not exceed 25 mm/min 1) Cover) |
- |
500 |
|
- |
| Cl.6.15 (2)(Rate of separation shall not exceed 25 mm/min 2) Jet) |
- |
500 |
|
- |
| Cl.6.16(When tested by the method prescribed in
IS 443 (Part 1), the lining (for Types 1, 2 and 3) and
cover (for Type 3 only) of the hose shall neither develop
cracking nor crazing when seen under X2
magnification, except at the cut edges of the hose) |
- |
25000 |
|
- |
| Cl.6.17(When tested in accordance with Annex F, at a test
temperature of, at a test temperature of 300 ± 10°C for
Types 1 and 2, and 400 ± 10° C for Type 3, in none of
the four tests shall the test piece show signs of leakage
within 120 s from the application of the filament rod or
on removal of this filament rod after the specified period) |
- |
10000 |
|
- |
| Cl.6.18(When tested in accordance with Annex H, the pressure
loss per 23 m length shall not exceed the values specified
in Table 3 at the specified flow rate and inlet pressure
(Recommendations for pressure testing of hoses in
service are given at Annex G).) |
- |
3000 |
|
- |
|
- |
- included w.e.f 16.03.2026 |
| 1207 |
HT Product Services Private Limited, Noida
| 8175006
| IS/IEC 62368 : Part 1 (2023) |
Audio Video Information and Communication Technology Equipment - Part 1: Safety Requirements (Second Revision) |
- |
60000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl-4.1(General- materials, components) |
- |
5000 |
|
- |
| Cl-4.2(Energy source classifications) |
- |
5000 |
|
- |
| Cl-4.3(Protection against energy sources) |
- |
5000 |
|
- |
| Cl-4.4(Safeguards) |
- |
5000 |
|
- |
| Cl-4.5(Explosion) |
- |
5000 |
|
- |
| Cl-4.6(Fixing of conductors and conductive parts) |
- |
5000 |
|
- |
| Cl-4.7(Equipment for direct insertion into mains socket-outlets) |
- |
5000 |
|
- |
| Cl-4.8(Equipment containing coin or button cell batteries) |
- |
5000 |
|
- |
| Cl-4.9(Likelihood of fire or shock due to entry of conductive objects) |
- |
5000 |
|
- |
| Cl-4.10(Components requirements) |
- |
5000 |
|
- |
| Cl-5.1(General- Electrically-caused injury) |
- |
5000 |
|
- |
| Cl-5.2(Classification and limits of electrical energy sources) |
- |
5000 |
|
- |
| Cl-5.3(Protection against electrical energy sources) |
- |
5000 |
|
- |
| Cl-5.4(Insulation materials and requirements) |
- |
5000 |
|
- |
| Cl-5.5(Components as safeguards) |
- |
5000 |
|
- |
| Cl-5.6(Protective conductor) |
- |
5000 |
|
- |
| Cl-5.7(Prospective touch voltage, touch current and protective conductor current) |
- |
5000 |
|
- |
| Cl-5.8(Backfeed safeguard in battery backed up supplies) |
- |
5000 |
|
- |
| Cl-6.1(General- Electrically-caused fire) |
- |
5000 |
|
- |
| Cl-6.2(Classification of power sources and potential ignition sources) |
- |
5000 |
|
- |
| Cl-6.3(Safeguards against fire under normal operating conditions and abnormal operating conditions) |
- |
5000 |
|
- |
| Cl-6.4(Safeguards against fire under single fault conditions) |
- |
5000 |
|
- |
| Cl-6.5(Internal and external wiring) |
- |
5000 |
|
- |
| Cl-7.1(General- Injury caused by hazardous substances) |
- |
5000 |
|
- |
| Cl-7.2(Reduction of exposure to hazardous substances) |
- |
5000 |
|
- |
| Cl-7.3(Ozone exposure) |
- |
5000 |
|
- |
| Cl-7.4(Use of personal safeguards or personal protective equipment (PPE) |
- |
5000 |
|
- |
| Cl-7.5(Use of instructional safeguards and instructions) |
- |
5000 |
|
- |
| Cl-8.1(General- Mechanically-caused injury) |
- |
5000 |
|
- |
| Cl-8.2(Mechanical energy source classifications) |
- |
5000 |
|
- |
| Cl-8.3(Safeguards against mechanical energy sources) |
- |
5000 |
|
- |
| Cl-8.4(Safeguards against parts with sharp edges and corners) |
- |
5000 |
|
- |
| Cl-8.5(Safeguards against moving parts) |
- |
5000 |
|
- |
| Cl-8.6(Stability of equipment) |
- |
5000 |
|
- |
| Cl-8.7(Equipment mounted to a wall, ceiling or other structure) |
- |
5000 |
|
- |
| Cl-8.8(Handle strength) |
- |
5000 |
|
- |
| Cl-8.9(Wheels or casters attachment requirements) |
- |
5000 |
|
- |
| Cl-8.10(Carts, stands, and similar carriers) |
- |
5000 |
|
- |
| Cl-8.11(Mounting means for slide-rail mounted equipment (SRME)) |
- |
5000 |
|
- |
| Cl-9.1(General-Thermal burn injury) |
- |
5000 |
|
- |
| Cl-9.2(Thermal energy source classifications) |
- |
5000 |
|
- |
| Cl-9.3(Touch temperature limits) |
- |
5000 |
|
- |
| Cl-9.4(Safeguards against thermal energy sources) |
- |
5000 |
|
- |
| Cl-9.5(Requirements for safeguards) |
- |
5000 |
|
- |
| Cl-9.6(Requirements for wireless power transmitters) |
- |
5000 |
|
- |
| Annex A(Examples of equipment within the scope of this document) |
- |
5000 |
|
- |
| Annex B(General- Normal operating condition tests, abnormal operating condition tests and single fault condition tests) |
- |
5000 |
|
- |
| Annex B-2(Normal operating conditions) |
- |
5000 |
|
- |
| Annex B-3(Simulated abnormal operating conditions) |
- |
5000 |
|
- |
| Annex B-4(Simulated single fault conditions) |
- |
5000 |
|
- |
| Annex D-1(Impulse test generators) |
- |
5000 |
|
- |
| Annex E-1(Electrical energy source classification for audio signals) |
- |
5000 |
|
- |
| Annex E-2(Audio signals used during test) |
- |
5000 |
|
- |
| Annex E-3(Operating conditions of equipment containing an audio amplifier) |
- |
5000 |
|
- |
| Annex F-1(General-Equipment markings, instructions, and instructional safeguards) |
- |
5000 |
|
- |
| Annex F-2(Letter symbols and graphical symbols) |
- |
5000 |
|
- |
| Annex F-3(Equipment markings) |
- |
5000 |
|
- |
| Annex F-4(Instructions) |
- |
5000 |
|
- |
| Annex F-5(Instructional safeguards) |
- |
5000 |
|
- |
| Annex G-16(IC that includes a capacitor discharge function (ICX)) |
- |
5000 |
|
- |
| Annex H-1(General- Criteria for telephone ringing signals) |
- |
5000 |
|
- |
| Annex H-2(Method A) |
- |
5000 |
|
- |
| Annex H-3(Method B) |
- |
5000 |
|
- |
| Annex I(Overvoltage categories (see IEC 60364-4-44)) |
- |
5000 |
|
- |
| Annex L-1(General requirements) |
- |
5000 |
|
- |
| Annex L-2(Permanently connected equipment) |
- |
5000 |
|
- |
| Annex L-3() |
- |
5000 |
|
- |
| Annex L-4(Single-phase equipment) |
- |
5000 |
|
- |
| Annex L-5(Three-phase equipment) |
- |
5000 |
|
- |
| Annex L-6(Switches as disconnect devices) |
- |
5000 |
|
- |
| Annex L-7(Plugs as disconnect devices) |
- |
5000 |
|
- |
| Annex L-8(Multiple power sources) |
- |
5000 |
|
- |
| Annex L-9(Compliance criteria) |
- |
5000 |
|
- |
| Annex M-1(General requirements) |
- |
5000 |
|
- |
| Annex M-2(Safety of batteries and their cells) |
- |
5000 |
|
- |
| Annex M-3(Protection circuits for batteries provided within the equipment) |
- |
5000 |
|
- |
| Annex M-4(Additional safeguards for equipment containing a secondary lithium battery) |
- |
5000 |
|
- |
| Annex M-5(Risk of burn due to short-circuit during carrying) |
- |
5000 |
|
- |
| Annex M-6(Safeguards against short-circuits) |
- |
5000 |
|
- |
| Annex M-7(Risk of explosion from lead acid and NiCd batteries) |
- |
5000 |
|
- |
| Annex M-8("Protection against internal ignition from external spark sources of
rechargeable batteries with aqueous electrolyte") |
- |
5000 |
|
- |
| Annex M-9(Preventing electrolyte spillage) |
- |
5000 |
|
- |
| Annex M-10(Instructions to prevent reasonably foreseeable misuse) |
- |
5000 |
|
- |
| Annex N(Electrochemical potentials (V)) |
- |
5000 |
|
- |
| Annex O(Measurement of creepage distances and clearances) |
- |
5000 |
|
- |
| Annex P-1(General-Safeguards against conductive objects) |
- |
5000 |
|
- |
| Annex P-2(Safeguards against entry or consequences of entry of a foreign object) |
- |
5000 |
|
- |
| Annex P-3(Safeguards against spillage of internal liquids) |
- |
5000 |
|
- |
| Annex P-4(Metallized coatings and adhesives securing parts) |
- |
5000 |
|
- |
| Annex Q-1(Limited power source) |
- |
5000 |
|
- |
| Annex Q-2(Test for external circuits – paired conductor cable) |
- |
5000 |
|
- |
| Annex R(Limited short-circuit test) |
- |
5000 |
|
- |
| Annex S-1(Flammability test for fire enclosure and fire barrier materials of equipment where the steady state power does not exceed 4 000 W) |
- |
5000 |
|
- |
| Annex S-2(Flammability test for fire enclosure and fire barrier integrity) |
- |
5000 |
|
- |
| Annex S-3(Flammability tests for the bottom of a fire enclosure) |
- |
5000 |
|
- |
| Annex S-4(Flammability classification of materials) |
- |
5000 |
|
- |
| Annex S-5(Flammability test for fire enclosure materials of equipment with a steady state power exceeding 4 000 W) |
- |
5000 |
|
- |
| Annex S-6(Grille covering material, cloth, and reticulated foam) |
- |
5000 |
|
- |
| Annex T-1(General-Mechanical strength tests) |
- |
5000 |
|
- |
| Annex T-2(Steady force test, 10 N) |
- |
5000 |
|
- |
| Annex T-3(Steady force test, 30 N) |
- |
5000 |
|
- |
| Annex T-4(Steady force test, 100 N) |
- |
5000 |
|
- |
| Annex T-5(Steady force test, 250 N) |
- |
5000 |
|
- |
| Annex T-6(Enclosure impact test) |
- |
5000 |
|
- |
| Annex T-7(Drop test) |
- |
5000 |
|
- |
| Annex T-8(Stress relief test) |
- |
5000 |
|
- |
| Annex T-9(Glass impact test) |
- |
5000 |
|
- |
| Annex T-10(Glass fragmentation test) |
- |
5000 |
|
- |
| Annex T-11(Test for telescoping or rod antennas) |
- |
5000 |
|
- |
| Annex V-1(Accessible parts of equipment) |
- |
5000 |
|
- |
| Annex V-2(Accessible part criterion) |
- |
5000 |
|
- |
| Annex W(Comparison of terms introduced in this document) |
- |
5000 |
|
- |
| Annex X("Alternative method for determining clearances for insulation in
circuits connected to an AC mains not exceeding 420 V peak (300 V RMS)") |
- |
5000 |
|
- |
| Annex Y-1(General- Construction requirements for outdoor enclosures) |
- |
5000 |
|
- |
| Annex Y-5(Protection of equipment within an outdoor enclosure) |
- |
5000 |
|
- |
| Annex Y-6(Mechanical strength of enclosures) |
- |
5000 |
|
- |
| Cl-4.1(General- materials, components) |
- |
- |
|
- |
| Cl-4.2(Energy source classifications) |
- |
- |
|
- |
| Cl-4.3(Protection against energy sources) |
- |
- |
|
- |
| Cl-4.4(Safeguards) |
- |
- |
|
- |
| Cl-4.5(Explosion) |
- |
- |
|
- |
| Cl-4.6(Fixing of conductors and conductive parts) |
- |
- |
|
- |
| Cl-4.7(Equipment for direct insertion into mains socket-outlets) |
- |
- |
|
- |
| Cl-4.8(Equipment containing coin or button cell batteries) |
- |
- |
|
- |
| Cl-4.9(Likelihood of fire or shock due to entry of conductive objects) |
- |
- |
|
- |
| Cl-4.10(Components requirements) |
- |
- |
|
- |
| Cl-5.1(General- Electrically-caused injury) |
- |
- |
|
- |
| Cl-5.2(Classification and limits of electrical energy sources) |
- |
- |
|
- |
| Cl-5.3(Protection against electrical energy sources) |
- |
- |
|
- |
| Cl-5.4(Insulation materials and requirements) |
- |
- |
|
- |
| Cl-5.5(Components as safeguards) |
- |
- |
|
- |
| Cl-5.6(Protective conductor) |
- |
- |
|
- |
| Cl-5.7(Prospective touch voltage, touch current and protective conductor current) |
- |
- |
|
- |
| Cl-5.8(Backfeed safeguard in battery backed up supplies) |
- |
- |
|
- |
| Cl-6.1(General- Electrically-caused fire) |
- |
- |
|
- |
| Cl-6.2(Classification of power sources and potential ignition sources) |
- |
- |
|
- |
| Cl-6.3(Safeguards against fire under normal operating conditions and abnormal operating conditions) |
- |
- |
|
- |
| Cl-6.4(Safeguards against fire under single fault conditions) |
- |
- |
|
- |
| Cl-6.5(Internal and external wiring) |
- |
- |
|
- |
| Cl-7.1(General- Injury caused by hazardous substances) |
- |
- |
|
- |
| Cl-7.2(Reduction of exposure to hazardous substances) |
- |
- |
|
- |
| Cl-7.3(Ozone exposure) |
- |
- |
|
- |
| Cl-7.4(Use of personal safeguards or personal protective equipment (PPE) |
- |
- |
|
- |
| Cl-7.5(Use of instructional safeguards and instructions) |
- |
- |
|
- |
| Cl-8.1(General- Mechanically-caused injury) |
- |
- |
|
- |
| Cl-8.2(Mechanical energy source classifications) |
- |
- |
|
- |
| Cl-8.3(Safeguards against mechanical energy sources) |
- |
- |
|
- |
| Cl-8.4(Safeguards against parts with sharp edges and corners) |
- |
- |
|
- |
| Cl-8.5(Safeguards against moving parts) |
- |
- |
|
- |
| Cl-8.6(Stability of equipment) |
- |
- |
|
- |
| Cl-8.7(Equipment mounted to a wall, ceiling or other structure) |
- |
- |
|
- |
| Cl-8.8(Handle strength) |
- |
- |
|
- |
| Cl-8.9(Wheels or casters attachment requirements) |
- |
- |
|
- |
| Cl-8.10(Carts, stands, and similar carriers) |
- |
- |
|
- |
| Cl-8.11(Mounting means for slide-rail mounted equipment (SRME)) |
- |
- |
|
- |
| Cl-9.1(General-Thermal burn injury) |
- |
- |
|
- |
| Cl-9.2(Thermal energy source classifications) |
- |
- |
|
- |
| Cl-9.3(Touch temperature limits) |
- |
- |
|
- |
| Cl-9.4(Safeguards against thermal energy sources) |
- |
- |
|
- |
| Cl-9.5(Requirements for safeguards) |
- |
- |
|
- |
| Cl-9.6(Requirements for wireless power transmitters) |
- |
- |
|
- |
| Annex A(Examples of equipment within the scope of this document) |
- |
- |
|
- |
| Annex B(General- Normal operating condition tests, abnormal operating condition tests and single fault condition tests) |
- |
- |
|
- |
| Annex B-2(Normal operating conditions) |
- |
- |
|
- |
| Annex B-3(Simulated abnormal operating conditions) |
- |
- |
|
- |
| Annex B-4(Simulated single fault conditions) |
- |
- |
|
- |
| Annex D-1(Impulse test generators) |
- |
- |
|
- |
| Annex E-1(Electrical energy source classification for audio signals) |
- |
- |
|
- |
| Annex E-2(Audio signals used during test) |
- |
- |
|
- |
| Annex E-3(Operating conditions of equipment containing an audio amplifier) |
- |
- |
|
- |
| Annex F-1(General-Equipment markings, instructions, and instructional safeguards) |
- |
- |
|
- |
| Annex F-2(Letter symbols and graphical symbols) |
- |
- |
|
- |
| Annex F-3(Equipment markings) |
- |
- |
|
- |
| Annex F-4(Instructions) |
- |
- |
|
- |
| Annex F-5(Instructional safeguards) |
- |
- |
|
- |
| Annex G-16(IC that includes a capacitor discharge function (ICX)) |
- |
- |
|
- |
| Annex H-1(General- Criteria for telephone ringing signals) |
- |
- |
|
- |
| Annex H-2(Method A) |
- |
- |
|
- |
| Annex H-3(Method B) |
- |
- |
|
- |
| Annex I(Overvoltage categories (see IEC 60364-4-44)) |
- |
- |
|
- |
| Annex L-1(General requirements) |
- |
- |
|
- |
| Annex L-2(Permanently connected equipment) |
- |
- |
|
- |
| Annex L-3() |
- |
- |
|
- |
| Annex L-4(Single-phase equipment) |
- |
- |
|
- |
| Annex L-5(Three-phase equipment) |
- |
- |
|
- |
| Annex L-6(Switches as disconnect devices) |
- |
- |
|
- |
| Annex L-7(Plugs as disconnect devices) |
- |
- |
|
- |
| Annex L-8(Multiple power sources) |
- |
- |
|
- |
| Annex L-9(Compliance criteria) |
- |
- |
|
- |
| Annex M-1(General requirements) |
- |
- |
|
- |
| Annex M-2(Safety of batteries and their cells) |
- |
- |
|
- |
| Annex M-3(Protection circuits for batteries provided within the equipment) |
- |
- |
|
- |
| Annex M-4(Additional safeguards for equipment containing a secondary lithium battery) |
- |
- |
|
- |
| Annex M-5(Risk of burn due to short-circuit during carrying) |
- |
- |
|
- |
| Annex M-6(Safeguards against short-circuits) |
- |
- |
|
- |
| Annex M-7(Risk of explosion from lead acid and NiCd batteries) |
- |
- |
|
- |
| Annex M-8("Protection against internal ignition from external spark sources of
rechargeable batteries with aqueous electrolyte") |
- |
- |
|
- |
| Annex M-9(Preventing electrolyte spillage) |
- |
- |
|
- |
| Annex M-10(Instructions to prevent reasonably foreseeable misuse) |
- |
- |
|
- |
| Annex N(Electrochemical potentials (V)) |
- |
- |
|
- |
| Annex O(Measurement of creepage distances and clearances) |
- |
- |
|
- |
| Annex P-1(General-Safeguards against conductive objects) |
- |
- |
|
- |
| Annex P-2(Safeguards against entry or consequences of entry of a foreign object) |
- |
- |
|
- |
| Annex P-3(Safeguards against spillage of internal liquids) |
- |
- |
|
- |
| Annex P-4(Metallized coatings and adhesives securing parts) |
- |
- |
|
- |
| Annex Q-1(Limited power source) |
- |
- |
|
- |
| Annex Q-2(Test for external circuits – paired conductor cable) |
- |
- |
|
- |
| Annex R(Limited short-circuit test) |
- |
- |
|
- |
| Annex S-1(Flammability test for fire enclosure and fire barrier materials of equipment where the steady state power does not exceed 4 000 W) |
- |
- |
|
- |
| Annex S-2(Flammability test for fire enclosure and fire barrier integrity) |
- |
- |
|
- |
| Annex S-3(Flammability tests for the bottom of a fire enclosure) |
- |
- |
|
- |
| Annex S-4(Flammability classification of materials) |
- |
- |
|
- |
| Annex S-5(Flammability test for fire enclosure materials of equipment with a steady state power exceeding 4 000 W) |
- |
- |
|
- |
| Annex S-6(Grille covering material, cloth, and reticulated foam) |
- |
- |
|
- |
| Annex T-1(General-Mechanical strength tests) |
- |
- |
|
- |
| Annex T-2(Steady force test, 10 N) |
- |
- |
|
- |
| Annex T-3(Steady force test, 30 N) |
- |
- |
|
- |
| Annex T-4(Steady force test, 100 N) |
- |
- |
|
- |
| Annex T-5(Steady force test, 250 N) |
- |
- |
|
- |
| Annex T-6(Enclosure impact test) |
- |
- |
|
- |
| Annex T-7(Drop test) |
- |
- |
|
- |
| Annex T-8(Stress relief test) |
- |
- |
|
- |
| Annex T-9(Glass impact test) |
- |
- |
|
- |
| Annex T-10(Glass fragmentation test) |
- |
- |
|
- |
| Annex T-11(Test for telescoping or rod antennas) |
- |
- |
|
- |
| Annex V-1(Accessible parts of equipment) |
- |
- |
|
- |
| Annex V-2(Accessible part criterion) |
- |
- |
|
- |
| Annex W(Comparison of terms introduced in this document) |
- |
- |
|
- |
| Annex X("Alternative method for determining clearances for insulation in
circuits connected to an AC mains not exceeding 420 V peak (300 V RMS)") |
- |
- |
|
- |
| Annex Y-1(General- Construction requirements for outdoor enclosures) |
- |
- |
|
- |
| Annex Y-5(Protection of equipment within an outdoor enclosure) |
- |
- |
|
- |
| Annex Y-6(Mechanical strength of enclosures) |
- |
- |
|
- |
|
03 Dec, 2026 |
- Included w.e.f-23.06.2026
"Cl-4.10 (Components requirements)
Cl-10.2 (Radiation energy source classifications)
Cl-10.3 (Safeguards against laser radiation)
Cl-10.4 (""Safeguards against optical radiation from lamps and lamp systems (including LED types)"")
Cl-10.5 (Safeguards against X-radiation)
Cl-10.6 (Safeguards against acoustic energy sources)
Annex C-1 (Protection of materials in equipment from UV radiation)
Annex C-2 (UV light conditioning test)
Annex G-1 (Switches)
Annex G-2 (Relays)
Annex G-3 (Protective devices)
Annex G-4 (Connectors)
Annex G-5 (Wound components)
Annex G-6 (Wire insulation)
Annex G-7 (Mains power supply cords and interconnection cables)
Annex G-8 (Varistors)
Annex G-9 (Integrated circuit (IC) current limiters)
Annex G-10 (Resistors)
Annex G-11 (Capacitors and RC units)
Annex G-12 (Optocouplers)
Annex G-13 (Printed boards)
Annex G-14 (Coatings on component terminals)
Annex G-15 (Pressurized liquid filled components or LFC assemblies)
Annex G-16 (IC that includes a capacitor discharge function (ICX))
Annex J-1 (General-Insulated winding wires for use without interleaved insulation)
Annex J-2 (Type tests)
Annex J-3 (Testing during manufacturing)
Annex K-1 (General- Safety interlocks)
Annex K-2 (Components of the safety interlock safeguard mechanism)
Annex K-3 (Inadvertent change of operating mode)
Annex K-4 (Interlock safeguard override)
Annex K-5 (Fail-safe)
Annex K-6 (Mechanically operated safety interlocks)
Annex K-7 (Interlock circuit isolation)
Annex U (""Mechanical strength of CRTs and protection against the effects of implosion"")
Annex Y-2 (Resistance to UV radiation)
Annex Y-3 (Resistance to corrosion)
Annex Y-4 (Gaskets)
Annex Y-5 (Protection of equipment within an outdoor enclosure)
Cl-10.1 (General-Radiation)
Annex D-2 (Antenna interface test generator)
Annex D-3 (Electronic pulse generator)" |
| 1208 |
QUALITY INTERNATIONAL RESEARCH & LABORATORIES PRIVATE LIMITED
| 5197006
| IS 432 : Part 1 (1982) |
Mild Steel and Medium Tensile Steel Bars and Hard-Drawn Steel Wire for Concrete Reinforcement: Part 1 Mild Steel and Medium Tensile Steel Bars |
Mild Steel and Medium Tensile Steel Bars and Hard-Drawn Steel Wire for Concrete Reinforcement: Part 1 Mild Steel and Medium Tensile Steel Bars |
12500 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl 5.1(Workmanship) |
- |
500 |
|
- |
| Cl 6.2(Diameter & Ovality) |
- |
500 |
|
- |
| Cl 6.2(Weight) |
- |
500 |
|
- |
| Cl 8.2(Bend test) |
- |
500 |
|
- |
| Cl 9.3(Press) |
- |
500 |
|
- |
| Cl 5.1(Workmanship) |
- |
500 |
|
- |
| Cl 6.1(Diameter) |
- |
500 |
|
- |
| Cl 6.2(Weight) |
- |
500 |
|
- |
| Cl 8.1(ultimate tensile stress, yield stress and percentage elongation) |
- |
500 |
|
- |
| Cl 9.3(Press) |
- |
500 |
|
- |
| Cl 5.1(Workmanship) |
- |
500 |
|
- |
| Cl 6.2(Diameter & Ovality) |
- |
500 |
|
- |
| Cl 6.2(Weight) |
- |
500 |
|
- |
| Cl 8(Physical Requirements) |
- |
500 |
|
- |
| Cl 9.3(Press) |
- |
500 |
|
- |
| Clause -4, 4.3(TITANIUM) |
- |
500 |
|
- |
| Clause -4, 4.2(VANADIUM) |
- |
500 |
|
- |
| Clause -4, 4.1(NIOBIUM) |
- |
500 |
|
- |
| Clause -4, 4.1(Molybdenum) |
- |
500 |
|
- |
| Clause -4, 4.1(Chromium) |
- |
500 |
|
- |
| Clause -4, 4.1(Nickel) |
- |
500 |
|
- |
| Clause -4, 4.1( ALUMINIUM) |
- |
500 |
|
- |
| Clause -4, 4.1(SILICON) |
- |
500 |
|
- |
| Clause -4, 4.1(NITROGEN) |
- |
500 |
|
- |
| Clause -4, 4.1(MANGANESE) |
- |
500 |
|
- |
| Clause -4, 4.1(PHOSPHURS) |
- |
500 |
|
- |
| Clause -4, 4.1(SULPHUR) |
- |
500 |
|
- |
| Clause -4, 4.1( CARBON) |
- |
500 |
|
- |
| Cl. 8.1 Table 1(Elongation) |
- |
500 |
|
- |
| Cl. 8.1 Table 1(Yield Stress) |
- |
500 |
|
- |
| Clause 8.1(Elongation) |
- |
500 |
|
- |
| Clause 8.1(Yield Stress) |
- |
500 |
|
- |
| Clause 9.3(Bend test) |
- |
500 |
|
- |
| Clause 6.1(Size) |
- |
500 |
|
- |
| Cl 9.3(Press) |
- |
500 |
|
- |
| Cl 8(UTM) |
- |
500 |
|
- |
| Cl 6.2(Weight) |
- |
500 |
|
- |
| Cl 6.2(Diameter & Ovality) |
- |
500 |
|
- |
| Cl 5.1(Workmanship) |
- |
500 |
|
- |
| 7(Tolerance) |
- |
500 |
|
- |
| Cl 5.1(Workmanship) |
- |
500 |
|
- |
| Cl 6.2(Diameter & Ovality) |
- |
500 |
|
- |
| Cl 6.2(Weight) |
- |
500 |
|
- |
| Cl 8(UTM) |
- |
500 |
|
- |
| Cl 9.3(Press) |
- |
500 |
|
- |
| Cl 4.1(Workmanship) |
- |
500 |
|
- |
| Cl 5 & 6(Diameter) |
- |
500 |
|
- |
| Cl 7(UTM) |
- |
500 |
|
- |
| Cl 8.3(Bending To Both Side At 90°, Then Straight) |
- |
500 |
|
- |
| Clause 5.1(IS 432 Part 1) |
- |
500 |
|
- |
| Clause 6.2(IS 1732) |
- |
500 |
|
- |
| Clause 8.1(IS 1608 Part 1) |
- |
500 |
|
- |
| Clause 4(Any Instrumental Method/Chemical Method) |
- |
500 |
|
- |
| Clause 4(By Calculation) |
- |
500 |
|
- |
| Clause 4(By Calculation) |
- |
500 |
|
- |
| Clause 4(Any Instrumental Method/Chemical Method) |
- |
500 |
|
- |
| Clause 5.1(Freedom from Defect) |
- |
500 |
|
- |
| Clause 6.2(Mass) |
- |
500 |
|
- |
| Clause 8.1(Ultimate Tensile Stress) |
- |
500 |
|
- |
| Clause 4(Boron) |
- |
500 |
|
- |
| Clause 4(By Calculation) |
- |
500 |
|
- |
| Clause 4(By Calculation) |
- |
500 |
|
- |
| Clause 4(Copper) |
- |
500 |
|
- |
| 8.1 & 9.2(Yield Strength - IS: 1608 (P1)) |
- |
500 |
|
- |
| 8.1 & 9.2(Elongation on SoA 5.65mm GL - IS: 1608 (P1)) |
- |
500 |
|
- |
| 11(Marking) |
- |
500 |
|
- |
| Clause 5.1(Freedom from Defect) |
- |
500 |
|
- |
| Clause 6.2(Mass) |
- |
500 |
|
- |
| Clause 8.1(Ultimate Tensile Stress) |
- |
500 |
|
- |
| Clause 4(Boron) |
- |
500 |
|
- |
| Clause 4(Carbon Equivalent) |
- |
500 |
|
- |
| Clause 4(Ni+V+Ti) |
- |
500 |
|
- |
| Clause 4(Copper) |
- |
500 |
|
- |
| Clause 4(Copper) |
- |
500 |
|
- |
|
- |
- Included w.e.f 16.03.2026 |
| 1209 |
ACCURATE TEST SOLUTIONS LLP (F21), NOIDA
| 8141226
| IS 16046 : Part 2 (2018) |
Secondary Cells and Batteries Containing Alkaline or Other Non-Acid Electrolytes ” Safety Requirements for Portable Sealed Secondary Cells and for Batteries Made from Them for Use in Portable Applications Part 2 Lithium Systems ( Second Revision ) |
- |
60000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4(Parameter Measurement Tolerances) |
- |
100 |
|
10 % discount (BIS) |
| 5(General Safety Considerations) |
- |
100 |
|
10 % discount (BIS) |
| 5.1(General) |
- |
250 |
|
10 % discount (BIS) |
| 5.2(Insulation and Wiring) |
- |
250 |
|
10 % discount (BIS) |
| 5.3(Venting) |
- |
250 |
|
10 % discount (BIS) |
| 5.4(Temperature, Voltage and Current Management) |
- |
250 |
|
10 % discount (BIS) |
| 5.5(Terminal Contacts) |
- |
250 |
|
10 % discount (BIS) |
| 5.6(Assembly of Cells into batteries) |
- |
250 |
|
10 % discount (BIS) |
| 5.7(Quality Plan) |
- |
200 |
|
10 % discount (BIS) |
| 5.8(Battery Safety Components) |
- |
200 |
|
10 % discount (BIS) |
| 6(Type Test and Sample Size) |
- |
100 |
|
10 % discount (BIS) |
| 7(Specific requirements and tests) |
- |
100 |
|
10 % discount (BIS) |
| 7.1(Charging procedure for test purposes) |
- |
8000 |
|
10 % discount (BIS) |
| 7.2(Intended Use) |
- |
10000 |
|
10 % discount (BIS) |
| 7.3(Reasonably foreseeable misuse) |
- |
30000 |
|
10 % discount (BIS) |
| 8(Information for safety) |
- |
1000 |
|
10 % discount (BIS) |
| 8.1(General) |
- |
1000 |
|
10 % discount (BIS) |
| 8.2(Small Cell and battery safety information) |
- |
1000 |
|
10 % discount (BIS) |
| 9(Marking) |
- |
200 |
|
10 % discount (BIS) |
| 9.1(Cell Marking) |
- |
1500 |
|
10 % discount (BIS) |
| 9.2(Battery Marking) |
- |
1500 |
|
10 % discount (BIS) |
| 9.3(Caution for ingestion of small cells and batteries) |
- |
1500 |
|
10 % discount (BIS) |
| 9.4(Other information) |
- |
1000 |
|
10 % discount (BIS) |
| 10(Packaging) |
- |
1000 |
|
10 % discount (BIS) |
| clause 7.3.1 of IS 16047: Part 3(Discharge performance at 20 °C (rated capacity)) |
- |
10000 |
|
10 % discount (BIS) |
| clause 7.3.1 of IS 16047: Part 3(Discharge performance at 20 °C (rated capacity)) |
- |
0 |
|
- |
|
04 Jul, 2027 |
- - |
| 1210 |
Stellar Test House, Noida
| 8171606
| IS 302 : PART 1 (Frying Pans, Deep Fat Fryers and similar appliances) |
Frying Pans, Deep Fat Fryers and similar appliances |
- |
30000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 6(Classifications) |
- |
500 |
|
- |
| 5(General conditions for tests) |
- |
500 |
|
- |
| 4(General Requirement) |
- |
500 |
|
- |
| 11.8(Temperature rise) |
- |
1000 |
|
- |
| 11.7(Duration corresponding) |
- |
1000 |
|
- |
| 11.6(Combined appliances) |
- |
1000 |
|
- |
| 11.5(Motor-operated appliances) |
- |
1000 |
|
- |
| 11.4(Heating appliances) |
- |
1000 |
|
- |
| 8.1.5(Live parts of built-in appliances) |
- |
1000 |
|
- |
| 18(Endurance) |
- |
1000 |
|
- |
| 17(Overload protection of transformers and associated circuits) |
- |
1000 |
|
- |
| 16(Leakage current and electric strength) |
- |
1000 |
|
- |
| 4(General requirement) |
- |
500 |
|
- |
| 32(Radiation Toxicity and Similar Hazards) |
- |
1000 |
|
- |
| 31(Resistance to Rusting) |
- |
1000 |
|
- |
| 30.2(Needle Flame Test) |
- |
1000 |
|
- |
| 30.2(Glow Wire Test) |
- |
1000 |
|
- |
| 30.1(Ball pressure test) |
- |
1000 |
|
- |
| 29(clearance, creepage distances and solid insulation) |
- |
1000 |
|
- |
| 28(Screw test and connections) |
- |
1000 |
|
- |
| 27(Provision for earthing) |
- |
1000 |
|
- |
| 26(Terminals for external conductors) |
- |
1000 |
|
- |
| 25(Supply connection and external flexible cords) |
- |
1000 |
|
- |
| 24(Components) |
- |
1000 |
|
- |
| 23(General) |
- |
1000 |
|
- |
| 22(Construction verification related test) |
- |
1000 |
|
- |
| 21(Mechanical Strength Test) |
- |
1000 |
|
- |
| 20(Stability test) |
- |
1000 |
|
- |
| 19(Abnormal Operation) |
- |
1000 |
|
- |
| 18(Endurance Test requirements and tests) |
- |
1000 |
|
- |
| 17(Over Load Protection of Transformers and associated circuits) |
- |
1000 |
|
- |
| 16.3(Electric Strength (after clause 15 and 16.2)) |
- |
1000 |
|
- |
| 16.2(Leakage Current (after Clause 15)) |
- |
1000 |
|
- |
| 16.1(General) |
- |
1000 |
|
- |
| 16.0(General) |
- |
1000 |
|
- |
| 15.3(Humidity Test) |
- |
1000 |
|
- |
| 15.2(Spillage Test) |
- |
1000 |
|
- |
| 15.1(Ingress Protection test other than IPX0 (IP test)) |
- |
1000 |
|
- |
| 15.0(General) |
- |
1000 |
|
- |
| 14(Transient Over Voltages) |
- |
1000 |
|
- |
| 13.3(Electric Strength at operating temperature) |
- |
1000 |
|
- |
| 13.2(Leakage current at operating temperature) |
- |
1000 |
|
- |
| 13.1(General) |
- |
1000 |
|
- |
| 11.3(Heating) |
- |
1000 |
|
- |
| 11.2(General) |
- |
1000 |
|
- |
| 11.1(General) |
- |
1000 |
|
- |
| 10.2(Current input) |
- |
1000 |
|
- |
| 10.1(Power input) |
- |
1000 |
|
- |
| 9(Starting of motor operation test requirements and tests) |
- |
1000 |
|
- |
| 8.1.4(Protection against live parts against protective impedance) |
- |
1000 |
|
- |
| 8.1.3(Protection against live parts in visible glowing heating elements) |
- |
1000 |
|
- |
| 8.1.2(Protection against live parts in openings) |
- |
1000 |
|
- |
| 8.1.1(Protection against live parts in all positions) |
- |
1000 |
|
- |
| 7(Marking and instructions) |
- |
500 |
|
- |
| 6(Classifications) |
- |
- |
|
- |
| 5(General conditions for tests) |
- |
- |
|
- |
| 4(General Requirement) |
- |
- |
|
- |
| 11.8(Temperature rise) |
- |
- |
|
- |
| 11.7(Duration corresponding) |
- |
- |
|
- |
| 11.6(Combined appliances) |
- |
- |
|
- |
| 11.5(Motor-operated appliances) |
- |
- |
|
- |
| 11.4(Heating appliances) |
- |
- |
|
- |
| 8.1.5(Live parts of built-in appliances) |
- |
- |
|
- |
| 18(Endurance) |
- |
- |
|
- |
| 17(Overload protection of transformers and associated circuits) |
- |
- |
|
- |
| 16(Leakage current and electric strength) |
- |
- |
|
- |
| 4(General requirement) |
- |
- |
|
- |
| 32(Radiation Toxicity and Similar Hazards) |
- |
- |
|
- |
| 31(Resistance to Rusting) |
- |
- |
|
- |
| 30.2(Needle Flame Test) |
- |
- |
|
- |
| 30.2(Glow Wire Test) |
- |
- |
|
- |
| 30.1(Ball pressure test) |
- |
- |
|
- |
| 29(clearance, creepage distances and solid insulation) |
- |
- |
|
- |
| 28(Screw test and connections) |
- |
- |
|
- |
| 27(Provision for earthing) |
- |
- |
|
- |
| 26(Terminals for external conductors) |
- |
- |
|
- |
| 25(Supply connection and external flexible cords) |
- |
- |
|
- |
| 24(Components) |
- |
- |
|
- |
| 23(General) |
- |
- |
|
- |
| 22(Construction verification related test) |
- |
- |
|
- |
| 21(Mechanical Strength Test) |
- |
- |
|
- |
| 20(Stability test) |
- |
- |
|
- |
| 19(Abnormal Operation) |
- |
- |
|
- |
| 18(Endurance Test requirements and tests) |
- |
- |
|
- |
| 17(Over Load Protection of Transformers and associated circuits) |
- |
- |
|
- |
| 16.3(Electric Strength (after clause 15 and 16.2)) |
- |
- |
|
- |
| 16.2(Leakage Current (after Clause 15)) |
- |
- |
|
- |
| 16.1(General) |
- |
- |
|
- |
| 16.0(General) |
- |
- |
|
- |
| 15.3(Humidity Test) |
- |
- |
|
- |
| 15.2(Spillage Test) |
- |
- |
|
- |
| 15.1(Ingress Protection test other than IPX0 (IP test)) |
- |
- |
|
- |
| 15.0(General) |
- |
- |
|
- |
| 14(Transient Over Voltages) |
- |
- |
|
- |
| 13.3(Electric Strength at operating temperature) |
- |
- |
|
- |
| 13.2(Leakage current at operating temperature) |
- |
- |
|
- |
| 13.1(General) |
- |
- |
|
- |
| 11.3(Heating) |
- |
- |
|
- |
| 11.2(General) |
- |
- |
|
- |
| 11.1(General) |
- |
- |
|
- |
| 10.2(Current input) |
- |
- |
|
- |
| 10.1(Power input) |
- |
- |
|
- |
| 9(Starting of motor operation test requirements and tests) |
- |
- |
|
- |
| 8.1.4(Protection against live parts against protective impedance) |
- |
- |
|
- |
| 8.1.3(Protection against live parts in visible glowing heating elements) |
- |
- |
|
- |
| 8.1.2(Protection against live parts in openings) |
- |
- |
|
- |
| 8.1.1(Protection against live parts in all positions) |
- |
- |
|
- |
| 7(Marking and instructions) |
- |
- |
|
- |
|
26 Sep, 2028 |
- Included w.e.f-04.08.2026
"19.11.4.7 (Harmonics)
19.11.4.6 (Class 3 Voltage dips and interruptions)
19.11.4.5 (Immunity to conducted discharges)
19.11.4.4 (Surge immunity test)
19.11.4.3 (Fast transient bursts)
19.11.4.2 (Radiated fields)
19.11.4.1 (Electrostatic discharges)" |
| 1211 |
BIS, Patna Branch Laboratory (PBL)
| None
| IS 6444 (2023) |
Sulphur Dusting Powders - Specification second revision |
- |
- View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 3.1 (Description - IS 6444:2023) |
- |
|
|
|
| 3.2.1 & 3.2 Table 1 (i) (Sulphr Content - IS 6444:2023) |
- |
|
|
|
| 3.2 Table 1 (ii) (Material passing through 75 micron IS Sieve - IS 6940:1982) |
- |
|
|
|
| 3.2 Table 1 (iii) (Bulk Density after compacting - IS 6940:1982) |
- |
|
|
|
|
- |
- - |
| 1212 |
BIS, Patna Branch Laboratory (PBL)
| None
| IS 3383 (2023) |
SULPHUR WETTABLE POWDERS SPECIFICATION |
- |
- View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 3.1 (Description - IS 3383:2023) |
- |
|
|
|
| 3.2.1 & 3.2 Table 1 (i) (Sulphr Content - IS 3383:2023) |
- |
|
|
|
| 3.2 Table 1 (ii) (Material passing through 45 micron IS Sieve - IS 6940:1982) |
- |
|
|
|
| 3.2 Table 1 (iii) (Suspensibility, after accelerated storage - IS 6940:1982) |
- |
|
|
|
| 3.2 Table 1 (iv) (Wettability - IS 6940:1982) |
- |
|
|
|
| 3.2 Table 1 (v) (Arsenic (as As) - IS 3383:2023) |
- |
|
|
|
| Cl-3.1 (Description) |
- |
|
|
|
| Cl-3.2, Table-1 (i) (Sulphur content, percent by mas, Min) |
- |
|
|
|
| Cl-3.2, Table-1 (ii) (Material passing through 45 micron IS Sieve [see IS 460 (Part 1)], after accelerated storage, percent by mass, Min) |
- |
|
|
|
| Cl-3.2, Table-1 (iii) (Suspensibility, after accelerated storage, percent by mass, Min) |
- |
|
|
|
| Cl-3.2, Table-1 (iv) (Wettability, Max) |
- |
|
|
|
| Cl-3.2, Table-1 (v) (Arsenic (as As), percent by mass, Max) |
- |
|
|
|
| Cl-3.2.1 (Sulphur Content) |
- |
|
|
|
| Cl-5 (Marking) |
- |
|
|
|
|
- |
- - |
| 1213 |
Bharat Test House Pvt Ltd 1474 Sonipat Haryana
| 9135626
| IS 9968 : Part 1 (2025) |
Elastomer Insulated Cables - Specification Part 1 for Working Voltages up to and including 1100 volts (Second Revision) |
Elastomer Insulated Cables for Working Voltages up to and including 1100 volts |
19750 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl-4.1(Copper Conductor) |
- |
50 |
|
Nil. |
| Cl-4.2(Aluminum Conductor) |
- |
50 |
|
Nil. |
| Cl-6.1(Proofed Tape) |
- |
50 |
|
Nil. |
| Cl-6.2("Polyethylene Terephthalate (PETP) Tape or
Plastic Tape or Any Other Suitable Tape") |
- |
50 |
|
Nil. |
| Cl-6.3(Glass Tape) |
- |
50 |
|
Nil. |
| Cl-7(Fillers) |
- |
50 |
|
Nil. |
| Cl-8.1(Textile Braid) |
- |
50 |
|
Nil. |
| Cl-8.2(Glass Braid) |
- |
50 |
|
Nil. |
| Cl-9.1(General Service Insulated Cables and Flexible Cords) |
- |
50 |
|
Nil. |
| Cl-9.2(Heat Resisting Insulated Cables) |
- |
50 |
|
Nil. |
| Cl-9.3(Silicon Rubber Insulated Cable) |
- |
50 |
|
Nil. |
| Cl-10.1(Preservative Compound) |
- |
50 |
|
Nil. |
| Cl-10.2(Varnish) |
- |
50 |
|
Nil. |
| Cl-12(separator tape) |
- |
50 |
|
Nil. |
| Cl-14(Core Identification) |
- |
50 |
|
Nil. |
| Cl-18(Laying UP of Cores) |
- |
50 |
|
Nil. |
| Cl-19(Binder Tape) |
- |
50 |
|
Nil. |
| Cl-20.2(Thickness of Sheath) |
- |
275 |
|
Nil. |
| Cl-20.3(Tolerance on Thickness of Sheath) |
- |
275 |
|
Nil. |
| Cl-20.4(Colour) |
- |
50 |
|
Nil. |
| Cl-22.1 (i) (a)(Conductor resistance test) |
- |
750 |
|
Nil. |
| Cl-22.1 (i) (b)(High voltage test or spark test.) |
- |
1250 |
|
Nil. |
| Cl-22.1 (ii) (a)(Annealing test (for copper);) |
- |
250 |
|
Nil. |
| Cl-22.1 (ii) (b)(Tensile Test ((for aluminium);) |
- |
250 |
|
Nil. |
| Cl-22.1 (ii) (c)(Wrapping test (for aluminium);) |
- |
100 |
|
Nil. |
| Cl-22.1 (ii) (f)(Tensile strength and elongation at break of insulation and sheath) |
- |
1000 |
|
Nil. |
| Cl-22.1 (ii) (g)(Hot set test for insulation and sheath) |
- |
1250 |
|
Nil. |
| Cl-22.1 (ii) (h)(High voltage test) |
- |
1200 |
|
Nil. |
| Cl-22.1 (ii) (i)(Insulation resistance test) |
- |
750 |
|
Nil. |
| Cl-22.1 (iii) (a)(Persulphate test (for tinned copper);) |
- |
1500 |
|
Nil. |
| Cl-22.1 (iii) (f)(Test for thickness of insulation and sheath and overall diameter) |
- |
300 |
|
Nil. |
| Electrical(Tensile strength and elongation at break) |
- |
1000 |
|
Nil. |
| Cl-22.1 (iii) (g), 2(Ageing in air oven) |
- |
1500 |
|
Nil. |
| Cl-22.1 (iii) (g), 3(Ageing in air bomb) |
- |
1500 |
|
Nil. |
| Cl-22.1 (iii) (g), 4(Ageing In oxygen bomb) |
- |
1500 |
|
Nil. |
| Cl-22.1 (iii) (g), 5(Hot set) |
- |
1250 |
|
Nil. |
| Cl-22.1 (iii) (g), 6(Oil resistance;) |
- |
1250 |
|
Nil. |
| Cl-22.1 (iii) (g), 7(Tear resistance) |
- |
350 |
|
Nil. |
| Cl-22.1 (iii) (i)(High voltage (water immersion) test;) |
- |
1250 |
|
Nil. |
| Cl-22.1 (iii) (j)(Flammability test) |
- |
1000 |
|
Nil. |
| Cl-22.1 (iii) (k)(Water absorption test (for insulation as applicable)) |
- |
1750 |
|
Nil. |
| Cl-24.1(Manufacturer’s Identification) |
- |
50 |
|
Nil. |
| Cl-25(Packing and Morning) |
- |
50 |
|
Nil. |
|
19 Mar, 2029 |
- included w.e.f 11.06.2026 |
| 1214 |
Stellar Test House, Noida
| 8171606
| IS 302 : PART 1 (Electric Forced Convection Ovens, Steam Cookers and Steam-Convection Ovens) |
Electric Forced Convection Ovens, Steam Cookers and Steam-Convection Ovens |
- |
30000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 6(Classifications) |
- |
500 |
|
- |
| 5(General conditions for tests) |
- |
500 |
|
- |
| 4(General Requirement) |
- |
500 |
|
- |
| 11.8(Temperature rise) |
- |
1000 |
|
- |
| 11.7(Duration corresponding) |
- |
1000 |
|
- |
| 11.6(Combined appliances) |
- |
1000 |
|
- |
| 11.5(Motor-operated appliances) |
- |
1000 |
|
- |
| 11.4(Heating appliances) |
- |
1000 |
|
- |
| 8.1.5(Live parts of built-in appliances) |
- |
1000 |
|
- |
| 18(Endurance) |
- |
1000 |
|
- |
| 17(Overload protection of transformers and associated circuits) |
- |
1000 |
|
- |
| 16(Leakage current and electric strength) |
- |
1000 |
|
- |
| 4(General requirement) |
- |
500 |
|
- |
| 32(Radiation Toxicity and Similar Hazards) |
- |
1000 |
|
- |
| 31(Resistance to Rusting) |
- |
1000 |
|
- |
| 30.2(Needle Flame Test) |
- |
1000 |
|
- |
| 30.2(Glow Wire Test) |
- |
1000 |
|
- |
| 30.1(Ball pressure test) |
- |
1000 |
|
- |
| 29(clearance, creepage distances and solid insulation) |
- |
1000 |
|
- |
| 28(Screw test and connections) |
- |
1000 |
|
- |
| 27(Provision for earthing) |
- |
1000 |
|
- |
| 26(Terminals for external conductors) |
- |
1000 |
|
- |
| 25(Supply connection and external flexible cords) |
- |
1000 |
|
- |
| 24(Components) |
- |
1000 |
|
- |
| 23(General) |
- |
1000 |
|
- |
| 22(Construction verification related test) |
- |
1000 |
|
- |
| 21(Mechanical Strength Test) |
- |
1000 |
|
- |
| 20(Stability test) |
- |
1000 |
|
- |
| 19(Abnormal Operation) |
- |
1000 |
|
- |
| 18(Endurance Test requirements and tests) |
- |
1000 |
|
- |
| 17(Over Load Protection of Transformers and associated circuits) |
- |
1000 |
|
- |
| 17(Over Load Protection of Transformers and associated circuits) |
- |
1000 |
|
- |
| 16.3(Electric Strength (after clause 15 and 16.2)) |
- |
1000 |
|
- |
| 16.2(Leakage Current (after Clause 15)) |
- |
1000 |
|
- |
| 16.1(General) |
- |
1000 |
|
- |
| 16.0(General) |
- |
1000 |
|
- |
| 15.3(Humidity Test) |
- |
1000 |
|
- |
| 15.2(Spillage Test) |
- |
1000 |
|
- |
| 15.1(Ingress Protection test other than IPX0 (IP test)) |
- |
1000 |
|
- |
| 15.0(General) |
- |
1000 |
|
- |
| 14(Transient Over Voltages) |
- |
1000 |
|
- |
| 13.3(Electric Strength at operating temperature) |
- |
1000 |
|
- |
| 13.2(Leakage current at operating temperature) |
- |
1000 |
|
- |
| 13.1(General) |
- |
1000 |
|
- |
| 11.3(Heating) |
- |
1000 |
|
- |
| 11.2(General) |
- |
1000 |
|
- |
| 11.1(General) |
- |
1000 |
|
- |
| 10.2(Current input) |
- |
1000 |
|
- |
| 10.1(Power input) |
- |
1000 |
|
- |
| 9(Starting of motor operation test requirements and tests) |
- |
1000 |
|
- |
| 8.1.4(Protection against live parts against protective impedance) |
- |
1000 |
|
- |
| 8.1.3(Protection against live parts in visible glowing heating elements) |
- |
1000 |
|
- |
| 8.1.2(Protection against live parts in openings) |
- |
1000 |
|
- |
| 8.1.1(Protection against live parts in all positions) |
- |
1000 |
|
- |
| 7(Marking and instructions) |
- |
500 |
|
- |
|
26 Sep, 2028 |
- Included w.e.f. 18.06.2026
19.11.4.7 (Harmonics)
19.11.4.6 (Class 3 Voltage dips and interruptions)
19.11.4.5 (Immunity to conducted discharges)
19.11.4.4 (Surge immunity test)
19.11.4.3 (Fast transient bursts)
19.11.4.2 (Radiated fields)
19.11.4.1 (Electrostatic discharges)" |
| 1215 |
JBS TESTING SOLUTIONS PVT LTD (27), JALANDHAR
| 9164606
| IS 16018 (2012) |
Wheeled fire extinguishers - Performance and construction - Specification |
- |
225000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Clause 8.4.1.1(Sulphur) |
- |
500 |
|
- |
| Clause 8.4.1.1(Phosphorus) |
- |
500 |
|
- |
| Clause 8.4.1.1(Carbon) |
- |
500 |
|
- |
| Clause 8.4.2.2(Carbon) |
- |
500 |
|
- |
| Cl 4(Types of Wheeled Fire Extinguishers) |
- |
1000 |
|
- |
| Cl 5.3(Fill Density) |
- |
10000 |
|
- |
| Cl 5.4(Filling Tolerance) |
- |
10000 |
|
- |
| Cl 5.5.1(Nominal Charge) |
- |
10000 |
|
- |
| Cl 6.1(Operating Temperature) |
- |
10000 |
|
- |
| Cl 6.2.1(Effective Discharge Time) |
- |
10000 |
|
- |
| Cl 6.2.2(Bulk Range) |
- |
10000 |
|
- |
| Cl 6.3(Resistance To Temperature Changes) |
- |
10000 |
|
- |
| Cl 6.5(Intermittent Discharge Test) |
- |
10000 |
|
- |
| Cl 7.5.1(Resistance to Impact) |
- |
10000 |
|
- |
| Cl 7.5.2(Resistance to Vibration) |
- |
10000 |
|
- |
| Cl 7.6(Resistance to Corrosion) |
- |
10000 |
|
- |
| Cl 7.7(Tapping Test) |
- |
10000 |
|
- |
| Cl 7.8(Intermittent Discharge Test) |
- |
10000 |
|
- |
| Cl 8.1(Rating Sutability for Various Classes of Fire) |
- |
10000 |
|
- |
| Cl 9.1(High Pressure Extinguishers) |
- |
25000 |
|
- |
| Cl 9.1.1(Pressure Cycling Test) |
- |
10000 |
|
- |
| Cl 9.2(Low Pressure Extinguishers) |
- |
50000 |
|
- |
| Cl 9.2.5(Welded Low Carbon Steel Cylinder) |
- |
500 |
|
- |
| Cl 9.2.6(Stainless Steel Cylinder) |
- |
500 |
|
- |
| Cl 9.2.7(Aluminium Cylinder) |
- |
500 |
|
- |
| Cl 9.3(Carrying Handle) |
- |
10000 |
|
- |
| Cl 9.4(Mounting) |
- |
10000 |
|
- |
| Cl 9.5(Caps, Valves and Closures) |
- |
10000 |
|
- |
| Cl 9.8.2(Requirements for Normally Pressurized Components) |
- |
10000 |
|
- |
| Cl 9.8.3(Ultraviolet Light Exposure) |
- |
10000 |
|
- |
| Cl 9.8.4(Impact Resistance) |
- |
10000 |
|
- |
| Cl 9.8.5(Normally Non Pressurized Components) |
- |
10000 |
|
- |
| Cl 9.8.6(Test for Exposure to Extinguishing Medium) |
- |
10000 |
|
- |
| Cl 9.9(Hose Assemblies) |
- |
10000 |
|
- |
| Cl 9.11(Safety Locking Devices) |
- |
10000 |
|
- |
| Cl 9.12.1(General ) |
- |
10000 |
|
- |
| Cl 9.12.2(Gauges and Indicators) |
- |
0 |
|
- |
| Cl 9.12.3(Gauges and Indicators) |
- |
0 |
|
- |
| Cl 9.12.4(Gauges and Indicators) |
- |
0 |
|
- |
| Cl 9.12.5(Gauges and Indicators) |
- |
0 |
|
- |
| Cl 9.12.6(Gauges and Indicators) |
- |
0 |
|
- |
| Cl 9.12.7(Gauges and Indicators) |
- |
0 |
|
- |
| Cl 9.13(Water Based Extinguishers) |
- |
10000 |
|
- |
| Cl 9.14(Special Requirements for CO2 Extinguishers) |
- |
0 |
|
- |
| Cl 10.1(Colour) |
- |
500 |
|
- |
| 9.1(Colour) |
- |
500 |
|
- |
| 8.18.3(Hose Retaining Unit) |
- |
10000 |
|
- |
| 8.18.2(Mobility) |
- |
10000 |
|
- |
| 8.18.1(Carriage Assembly) |
- |
10000 |
|
- |
| 8.17(Dip tubes and Filters for water based Extinguisher) |
- |
10000 |
|
- |
| 8.16(Pressure gauges for low pressure extinguishers) |
- |
10000 |
|
- |
| 8.15(Safety Locking Devices) |
- |
10000 |
|
- |
| 8.14(Method of operation for gas cartridge type extinguishers) |
- |
10000 |
|
- |
| 8.14(Method of operation for carbon dioxide extinguishers) |
- |
10000 |
|
- |
| 8.13.3(Load test on discharge horn) |
- |
10000 |
|
- |
| 8.13.2(Requirement to prevent loosening or detachment) |
- |
10000 |
|
- |
| 8.13.1(Horn of carbon dioxide extinguisher) |
- |
10000 |
|
- |
| 8.12(Control valve test) |
- |
10000 |
|
- |
| 8.11.3(Requirement of burst pressure of hose assemblies for carbon dioxide fire extinguishers) |
- |
10000 |
|
- |
| 8.11.3(Requirement of burst pressure of hose assemblies for except carbon dioxide fire extinguishers) |
- |
10000 |
|
- |
| 8.11.2(Requirement of hose and coupling system) |
- |
10000 |
|
- |
| 8.11.1(Requirement of the Discharge Assemblies) |
- |
10000 |
|
- |
| 8.9.2(Leakage Test) |
- |
10000 |
|
- |
| 8.8(Safety and Anti-overfill devices) |
- |
10000 |
|
- |
| 8.7.6(Requirement of edges and surfaces) |
- |
10000 |
|
- |
| 8.7.5(Requirement of burst test of cap,valve and closure) |
- |
10000 |
|
- |
| 8.7.4(Requirement of collar) |
- |
10000 |
|
- |
| 8.7.3(Requirement of filling opening diameter) |
- |
10000 |
|
- |
| 8.7.2(Requirement of threaded connections on cylinder) |
- |
10000 |
|
- |
| 8.7.1(Caps valves and closure) |
- |
10000 |
|
- |
| 8.6(Minimum wall thickness of the cylinder) |
- |
1000 |
|
- |
| 8.3.3(Pressure cycling Test) |
- |
10000 |
|
- |
| 8.3.2(Deformation Test) |
- |
10000 |
|
- |
| 8.3.1(Burst Test) |
- |
10000 |
|
- |
| 8.2(High Pressure Cylinder) |
- |
25000 |
|
- |
| 8.1.7(Drain Plug) |
- |
10000 |
|
- |
| 8.1.6(Thread of Plastic Components) |
- |
10000 |
|
- |
| 8.1.4(Construction Requirement) |
- |
10000 |
|
- |
| 8.1.3(Requirement of Welding) |
- |
10000 |
|
- |
| 8.1.2(Leakage Observation during conditioning Test) |
- |
10000 |
|
- |
| 7.2(Class 'B' Fire Test 233B) |
- |
76000 |
|
Rs. 45000/- (except fire performance test) For B - Class: 8B-Rs. 4500/- 13B-Rs. 5000/- 21B-Rs. 6000/- 34B-Rs. 26000/- 55B-Rs. 33000/- 70B-Rs. 39000/- 89B-Rs. 44000/- 113B-Rs. 49000/- 144B-Rs. 58000/- 183B-Rs. 67500/- 233B-Rs. 76000/- |
| 7.2(Class 'B' Fire Test 183B) |
- |
67500 |
|
- |
| 7.2(Class 'B' Fire Test 144B) |
- |
58000 |
|
- |
| 7.2(Class 'B' Fire Test 113B) |
- |
49000 |
|
- |
| 7.2(Class 'B' Fire Test 89B) |
- |
44000 |
|
- |
| 7.2(Class 'B' Fire Test 70B) |
- |
39000 |
|
- |
| 7.2(Class 'B' Fire Test 55B) |
- |
33000 |
|
- |
| 7.2(Class 'B' Fire Test 34B) |
- |
26000 |
|
- |
| 7.2(Class 'B' Fire Test 21B) |
- |
6000 |
|
- |
| 7.2(Class 'B' Fire Test 13B) |
- |
5000 |
|
- |
| 7.2(Class 'B' Fire Test 8B) |
- |
4500 |
|
- |
| 7.2(Class 'A' Fire Test 20A) |
- |
68000 |
|
- |
| 7.2(Class 'A' Fire Test 15A) |
- |
50000 |
|
- |
| 7.2(Class 'A' Fire Test 10A) |
- |
39000 |
|
- |
| 7.2(Class 'A' Fire Test 6A) |
- |
28000 |
|
- |
| 7.2(Class 'A' Fire Test 4A) |
- |
22000 |
|
- |
| 7.2(Class 'A' Fire Test 3A) |
- |
15000 |
|
- |
| 7.2(Class 'A' Fire Test 2A) |
- |
10000 |
|
- |
| 7.2(Class 'A' Fire Test 1A) |
- |
7000 |
|
- |
| 6.7.4(Displaced Test) |
- |
10000 |
|
- |
| 6.7.3(Nozzle Drop Test) |
- |
10000 |
|
- |
| 6.7.2(Durability test of trailer mounted fire extinguisher) |
- |
10000 |
|
- |
| 6.7.1(Observation of Durability Test after Nozzle Drop Test and Displaced Test) |
- |
10000 |
|
- |
| 6.6.2(Internal Corrosion Test) |
- |
10000 |
|
- |
| 6.6.1(External Corrosion Test) |
- |
10000 |
|
- |
| 6.4(Retention of charge) |
- |
10000 |
|
- |
| 5.5.2(Gross Mass) |
- |
10000 |
|
- |
| 3.16 and 8.1.1(Determination of maximum service pressure) |
- |
10000 |
|
- |
| 3.19 and 8.3(Determination of Service Pressure) |
- |
10000 |
|
- |
| Cl no 4(16018 :2012) |
- |
10000 |
|
- |
| Cl no 5.3(16018 :2012) |
- |
10000 |
|
- |
| Cl no 5.4(16018 :2012) |
- |
9999.98 |
|
- |
| Cl no 5.5.1(16018 :2012) |
- |
10000 |
|
- |
| Cl no 5.5.2(16018 :2012) |
- |
10000 |
|
- |
| Cl no 6.1(16018 :2012) |
- |
10000 |
|
- |
| Cl no 6.2.1 & 6.2.1.1(16018 :2012) |
- |
10000 |
|
- |
| Cl no 6.2.2 & 6.2.2.1(16018 :2012) |
- |
10000 |
|
- |
| Cl no 6.3 & 6.3.1(16018 :2012) |
- |
10000 |
|
- |
| Cl no 6.4(16018 :2012) |
- |
10000 |
|
- |
| Cl no 6.5(16018 :2012) |
- |
10000 |
|
- |
| Cl no 6.6.1(16018 :2012) |
- |
10000 |
|
- |
| Cl no 6.6.2(16018 :2012) |
- |
10000 |
|
- |
| Cl no 6.7(16018 :2012) |
- |
10000 |
|
- |
| Cl no 6.8(16018 :2012) |
- |
10000 |
|
- |
| Cl no 7.1(16018 :2012) |
- |
10000 |
|
- |
| Cl no 8.2(16018 :2012) |
- |
10000 |
|
- |
| Cl no 8.1(16018 :2012) |
- |
10000 |
|
- |
| Cl no 8.3(16018 :2012) |
- |
10000 |
|
- |
| Cl no 8.3.1(16018 :2012 Burst test) |
- |
10000 |
|
- |
| Cl no 8.3.2(16018 :2012) |
- |
10000 |
|
- |
| Cl no 8.3.3(16018 :2012) |
- |
10000 |
|
- |
| Cl no 8.4.1(Welded low carbon steel) |
- |
10000 |
|
- |
| Cl no 8.4.2.2(16018 :2012) |
- |
10000 |
|
- |
| Cl no 8.6(16018 :2012) |
- |
10000 |
|
- |
| Cl no 8.7(16018 :2012) |
- |
10000 |
|
- |
| Cl no 8.7.2(16018 :2012) |
- |
10000 |
|
- |
| Cl no 8.7.3(16018 :2012) |
- |
10000 |
|
- |
| Cl no 8.7.4(16018 :2012) |
- |
10000 |
|
- |
| Cl no 8.7.5(16018 :2012) |
- |
10000 |
|
- |
| Cl no 8.7.6(16018 :2012) |
- |
10000 |
|
- |
| Cl no 8.8.1(16018 :2012) |
- |
10000 |
|
- |
| Cl no 8.8.2(16018 :2012) |
- |
10000 |
|
- |
| Cl no 8.9.2(16018 :2012) |
- |
10000 |
|
- |
| Cl no 8.12(16018 :2012) |
- |
10000 |
|
- |
| Cl no 8.13.1 to 8.13.3(Horn for Carbon Di-oxide
Extinguishers) |
- |
10000 |
|
- |
| Cl no 8.14(16018 :2012) |
- |
10000 |
|
- |
| Cl no 8.15(16018 :2012) |
- |
10000 |
|
- |
| Cl no 8.17(16018 :2012) |
- |
10000 |
|
- |
| Cl no 8.18.1(16018 :2012) |
- |
10000 |
|
- |
| Cl no 8.18.2(16018 :2012) |
- |
10000 |
|
- |
| Cl no 8.18.3(16018 :2012) |
- |
10000 |
|
- |
| Cl no 9.1(16018 :2012) |
- |
10000 |
|
- |
| Cl no 9.2(16018 :2012) |
- |
10000 |
|
- |
| Cl no 4(16018 :2012) |
- |
10000 |
|
- |
| Cl no 5.4(16018 :2012) |
- |
10000 |
|
- |
| Cl no 5.3(16018 :2012) |
- |
10000 |
|
- |
| Cl no 5.5.1(16018 :2012) |
- |
10000 |
|
- |
| Cl no 5.5.2(16018 :2012) |
- |
10000 |
|
- |
| Cl no 6.1(16018 :2012) |
- |
10000 |
|
- |
| Cl no 6.2.1 & 6.2.1.1(16018 :2012) |
- |
10000 |
|
- |
| Cl no 6.2.2 & 6.2.2.1(16018 :2012) |
- |
10000 |
|
- |
| Cl no 6.3 & 6.3.1(16018 :2012) |
- |
10000 |
|
- |
| Cl no 6.4(16018 :2012) |
- |
10000 |
|
- |
| Cl no 6.5(16018 :2012) |
- |
10000 |
|
- |
| Cl no 6.6.1(16018 :2012) |
- |
10000 |
|
- |
| Cl no 6.6.2(16018 :2012) |
- |
10000 |
|
- |
| Cl no 6.7(16018 :2012) |
- |
10000 |
|
- |
| Cl no 6.8(16018 :2012) |
- |
10000 |
|
- |
| Cl no 7.1(16018 :2012) |
- |
10000 |
|
- |
| Cl no 8.1(16018 :2012) |
- |
10000 |
|
- |
| Cl no 8.2(16018 :2012) |
- |
10000 |
|
- |
| Cl no 8.3(16018 :2012) |
- |
10000 |
|
- |
| Cl no 8.3.1(16018 :2012) |
- |
10000 |
|
- |
| Cl no 8.3.2(16018 :2012) |
- |
10000 |
|
- |
| Cl no 8.3.3(16018 :2012) |
- |
10000 |
|
- |
| Cl no 8.4.1(16018 :2012) |
- |
10000 |
|
- |
| Cl no 8.4.2(16018 :2012) |
- |
10000 |
|
- |
| Cl no 8.6(16018 :2012) |
- |
10000 |
|
- |
| Cl no 8.7(16018 :2012) |
- |
10000 |
|
- |
| Cl no 8.7.2(16018 :2012) |
- |
10000 |
|
- |
| Cl no 8.7.3(16018 :2012) |
- |
10000 |
|
- |
| Cl no 8.7.4(16018 :2012) |
- |
10000 |
|
- |
| Cl no 8.7.5(16018 :2012) |
- |
10000 |
|
- |
| Cl no 8.7.6(16018 :2012) |
- |
10000 |
|
- |
| Cl no 8.8.1(16018 :2012) |
- |
10000 |
|
- |
| Cl no 8.9.2(16018 :2012) |
- |
10000 |
|
- |
| Cl no 8.11.1 to 8.11.3(Discharge assembly) |
- |
10000 |
|
- |
| Cl no 8.12(16018 :2012) |
- |
10000 |
|
- |
| Cl no 8.13.1(16018 :2012) |
- |
10000 |
|
- |
| Cl no 8.14(16018 :2012) |
- |
10000 |
|
- |
| Cl no 8.15(16018 :2012) |
- |
10000 |
|
- |
| Cl no 8.17(16018 :2012) |
- |
10000 |
|
- |
| Cl no 8.18.1(16018 :2012) |
- |
10000 |
|
- |
| Cl no 8.18.2(16018 :2012) |
- |
10000 |
|
- |
| Cl no 8.18.3(16018 :2012) |
- |
10000 |
|
- |
| Cl no 9.1(16018 :2012) |
- |
10000 |
|
- |
| Cl no 9.2(16018 :2012) |
- |
10000 |
|
- |
| 8.10.5(Exposure to extinguishing agent test) |
- |
10000 |
|
- |
| 8.10.1.4(Requirements of plastic components (Impact test)) |
- |
10000 |
|
- |
| 8.19(Gasket and O-rings) |
- |
10000 |
|
- |
| Cl-8.4.2(Stainless steel cylinder) |
- |
10000 |
|
- |
| Cl-8.4.3(Carbon dioxide
extinguisher) |
- |
10000 |
|
- |
| Cl-8.5(Aluminium cylinder) |
- |
10000 |
|
- |
| cl-8.9.1(Low pressure cylinder) |
- |
10000 |
|
- |
| Cl- 8.16.1.1 to 8.16.1.7(Pressure gauges for low pressure extinguishers-General) |
- |
10000 |
|
- |
| Cl- 8.16.2 , 8.16.2.1 & 8.16.2.2(Pressure gauge calibration test) |
- |
10000 |
|
- |
| Cl- 8.16.3.1 & 8.16.3.2(Pressure gauge for Burst strength test) |
- |
10000 |
|
- |
| Cl- 8.16.4.1 & 8.16.4.2(Pressure gauge for Over pressure test) |
- |
10000 |
|
- |
| Cl- 8.16.5.1 & 8.16.5.2(Pressure gauge for impulse test) |
- |
10000 |
|
- |
| Cl- 8.16.6.1 & 8.16.6.2(Pressure gauge for relief test) |
- |
10000 |
|
- |
| Cl- 8.16.7(Pressure gauge for Water resistance test) |
- |
10000 |
|
- |
| Cl- 8.16.8(Pressure gauge for Leakage test) |
- |
10000 |
|
- |
| Cl- 8.16.9 8.10(Pressure gauge Plastic components) |
- |
10000 |
|
- |
| 7.3(Class B and Class C Fire Tests) |
- |
10000 |
|
- |
| Cl-7.2 (Amendment -1)(Class A, Class B and Class C Fire Test) |
- |
200000 |
|
- |
|
- |
- included w.e.f 16.03.2026 |
| 1216 |
Bharat Test House Pvt Ltd 1474 Sonipat Haryana
| 9135626
| IS 5950 (2024) |
Shot Firing Cables (for Use Other than in Shafts) - Specification (Second Revision) |
Shot Firing Cables |
9500 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Section-2, Cl-3(CONDUCTOR) |
- |
50 |
|
Nil. |
| Section-2, Cl-4(INSULATION) |
- |
50 |
|
Nil. |
| Section-2, Cl-5(SHEATH) |
- |
50 |
|
Nil. |
| Section-3, Cl-6(CONDUCTOR) |
- |
50 |
|
Nil. |
| Section-3, Cl-7.1.1(Thickness of Insulation & Sheath) |
- |
100 |
|
Nil. |
| Section-3, Cl-7.1.2(Type II) |
- |
100 |
|
Nil. |
| Section-3, Cl-7.2(Tolerance on Thickness of Insulation) |
- |
100 |
|
Nil. |
| Section-3, Cl-7.3(Colour of Insulation) |
- |
50 |
|
Nil. |
| Section-3, Cl-8.1(Single-Core) |
- |
50 |
|
Nil. |
| Section-3, Cl-8.2(Tolerance on Thickness of Sheath) |
- |
150 |
|
Nil. |
| Section-3, Cl-8.3(Color of Sheath) |
- |
50 |
|
Nil. |
| Cl-10.2(Voltage Test) |
- |
750 |
|
Nil. |
| Cl-10.3(Spark Test) |
- |
1300 |
|
Nil. |
| Cl-10.4(Flammability Test) |
- |
1500 |
|
Nil. |
| Cl-9.1 (a)(Annealing test;) |
- |
200 |
|
Nil. |
| Cl-9.1 (b)(Conductor resistance test) |
- |
500 |
|
Nil. |
| Cl-9.1 (c)(Test for thickness of insulation and sheath) |
- |
200 |
|
Nil. |
| Cl-9.1 (d) 1(Tensile strength and elongation at break) |
- |
1000 |
|
Nil. |
| Cl-9.1 (d) 2(Ageing in air oven) |
- |
1500 |
|
Nil. |
| Cl-9.1 (d) 3(Loss of mass test) |
- |
500 |
|
Nil. |
| Cl-9.1 (d) 4(Hot deformation) |
- |
300 |
|
Nil. |
| Cl-9.1 (d) 5(Heat shock) |
- |
250 |
|
Nil. |
| Cl-9.1 (d) 6(hrinkage) |
- |
200 |
|
Nil. |
| Cl-9.2 , e(Insulation resistance test) |
- |
500 |
|
Nil. |
|
19 Mar, 2029 |
- included w.e.f 11.06.2026 |
| 1217 |
JBS TESTING SOLUTIONS (Unit-2) (24), Jalandhar
| 9172306
| IS 3614 (2021) |
Specification of Fire Doors and Assembly First Revision of IS 3614 Parts 1 2 |
- |
350000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4(Integrity, Insulation) |
- |
350000 |
|
- |
| Cl 7.2.2(SIZE (width)) |
- |
1000 |
|
- |
| Cl 7.2.2(SIZE (Height)) |
- |
1000 |
|
- |
| Cl 7.3.2(SIZE (width)) |
- |
1000 |
|
- |
| Cl 7.3.2(SIZE (Height)) |
- |
1000 |
|
- |
| Cl 7.4.2(SIZE (width)) |
- |
1000 |
|
- |
| Cl 7.4.2(SIZE (Height)) |
- |
1000 |
|
- |
| Cl 7.5.2(SIZE (width)) |
- |
1000 |
|
- |
| Cl 7.5.2(SIZE (Height)) |
- |
1000 |
|
- |
| 7.3.1(MOISTURE CONTENT) |
- |
3000 |
|
- |
| 7.2.7(Vision Pane (Uninsulated door) Width) |
- |
1000 |
|
- |
| 7.2.7(Vision Pane (Uninsulated door) Height) |
- |
1000 |
|
- |
| 7.2.7(Vision Pane (Insulated door) Width) |
- |
1000 |
|
- |
| 7.2.7(Vision Pane (Insulated door) Height) |
- |
1000 |
|
- |
| 7.3.4(Vision Pane (Width)) |
- |
1000 |
|
- |
| 7.3.4(Vision Pane (Height)) |
- |
1000 |
|
- |
| Cl-7.2.1(Material) |
- |
2500 |
|
- |
| Cl-7.2.4(Fire Door Frames) |
- |
1000 |
|
- |
| Cl-7.2.5(Door Leaf) |
- |
1000 |
|
- |
| Cl-7.2.8(Louvres) |
- |
1000 |
|
- |
| Cl-7.2.9(Builder’s Hardware) |
- |
1000 |
|
- |
| Cl-7.4.3(Construction) |
- |
1000 |
|
- |
| Cl-7.4.5(Operator) |
- |
1000 |
|
- |
| Cl-7.5.1(Material) |
- |
2500 |
|
- |
| Cl-7.5.3(Construction of Sliding Door Leaf) |
- |
1000 |
|
- |
| Cl-11.3.1(Walls) |
- |
1000 |
|
- |
| Cl-11.4.1(Closing Devices) |
- |
1000 |
|
- |
| Cl-11.4.2(Releasing Devices) |
- |
1000 |
|
- |
| Cl-11.4.3(Hardware) |
- |
1000 |
|
- |
| Cl-6(VISION PANE ON FIRE DOORS) |
- |
2000 |
|
- |
| Cl-7.2.3(Construction) |
- |
2000 |
|
- |
| Cl-7.2.6(Intumescent Seal) |
- |
1000 |
|
- |
| Cl-7.3.6(Builder’s Hardware) |
- |
1000 |
|
- |
| Cl-7.4.4(General Requirement of Fire Rated Rolling
Shutter) |
- |
1000 |
|
- |
| Cl-7.5.4(General Requirement of Fire Rated Sliding Door) |
- |
1000 |
|
- |
| Cl-7.6(General Requirement of Fire Doors) |
- |
1000 |
|
- |
| Cl-7.3.3(Construction) |
- |
1000 |
|
- |
| Cl-7.4(Avg closing speed of fire rated rolling shutters) |
- |
1000 |
|
- |
|
22 May, 2029 |
- included w.e.f 16.03.2026 |
| 1218 |
Standard Testing and Compliance Private Limited
| 6178726
| IS 10322 (Part 5/Sec 18) (2026) |
Luminaires Part 5 Particular requirements Section 18 Luminaires for swimming pools and similar applications |
- |
150000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl-18.4(General test requirements) |
- |
5000 |
|
- |
| Cl-18.6(Marking) |
- |
3000 |
|
- |
| Cl-18.6.2(Marking) |
- |
3000 |
|
- |
| Cl-18.7.2(Construction-mechanical strength) |
- |
12000 |
|
- |
| Cl-18.7.3(Construction-corrosion test) |
- |
12000 |
|
- |
| Cl-18.8(Creepage distances and clearances) |
- |
8000 |
|
- |
| Cl-18.10(Terminals) |
- |
10000 |
|
- |
| Cl-18.11(External and internal wiring) |
- |
10000 |
|
- |
| Cl-18.12(Protection against electric shock) |
- |
10000 |
|
- |
| Cl-18.13.2(Relevant tests) |
- |
15000 |
|
- |
| Cl-18.13.3(Endurance tests and thermal tests) |
- |
20000 |
|
- |
| Cl-18.14.2(moisture) |
- |
12000 |
|
- |
| Cl-18.14.3(Thermal shock test) |
- |
8000 |
|
- |
| Cl-18.15(Insulation resistance and electric strength) |
- |
7000 |
|
- |
| Cl-18.16(Resistance to heat, fire and tracking) |
- |
15000 |
|
- |
|
10 Jul, 2027 |
- included w.e.f 11.06.2026 |
| 1219 |
JBS TESTING SOLUTIONS PVT LTD (27), JALANDHAR
| 9164606
| IS 15834 (2020) |
Stainless Steel Sliding Door Bolts ( Aldrops ) for Use With Padlocks - Specification ( First Revision ) |
- |
11500 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl 5(DIMENSIONS AND TOLERANCES) |
- |
11500 |
|
6000: For complete mechanical and dimensional tests
4000: For complete chemical test
1500: For complete qualitative and other finish tests |
| Cl 5(DIMENSIONS AND TOLERANCES) |
- |
11500 |
|
6000: For complete mechanical and dimensional tests
4000: For complete chemical test
1500: For complete qualitative and other finish tests |
| Cl 5(DIMENSIONS AND TOLERANCES) |
- |
11500 |
|
6000: For complete mechanical and dimensional tests
4000: For complete chemical test
1500: For complete qualitative and other finish tests |
| Cl 5(DIMENSIONS AND TOLERANCES) |
- |
11500 |
|
6000: For complete mechanical and dimensional tests
4000: For complete chemical test
1500: For complete qualitative and other finish tests |
| Cl 5(DIMENSIONS AND TOLERANCES) |
- |
11500 |
|
6000: For complete mechanical and dimensional tests
4000: For complete chemical test
1500: For complete qualitative and other finish tests |
| Cl 5(DIMENSIONS AND TOLERANCES) |
- |
11500 |
|
6000: For complete mechanical and dimensional tests
4000: For complete chemical test
1500: For complete qualitative and other finish tests |
| Cl 5(DIMENSIONS AND TOLERANCES) |
- |
11500 |
|
6000: For complete mechanical and dimensional tests
4000: For complete chemical test
1500: For complete qualitative and other finish tests |
| Cl 5(DIMENSIONS AND TOLERANCES) |
- |
11500 |
|
6000: For complete mechanical and dimensional tests
4000: For complete chemical test
1500: For complete qualitative and other finish tests |
| Cl 5(DIMENSIONS AND TOLERANCES) |
- |
11500 |
|
6000: For complete mechanical and dimensional tests
4000: For complete chemical test
1500: For complete qualitative and other finish tests |
| Cl 5(DIMENSIONS AND TOLERANCES) |
- |
11500 |
|
6000: For complete mechanical and dimensional tests
4000: For complete chemical test
1500: For complete qualitative and other finish tests |
| Cl 5(DIMENSIONS AND TOLERANCES) |
- |
11500 |
|
6000: For complete mechanical and dimensional tests
4000: For complete chemical test
1500: For complete qualitative and other finish tests |
| Cl 5(DIMENSIONS AND TOLERANCES) |
- |
11500 |
|
6000: For complete mechanical and dimensional tests
4000: For complete chemical test
1500: For complete qualitative and other finish tests |
| Cl 5(DIMENSIONS AND TOLERANCES) |
- |
11500 |
|
6000: For complete mechanical and dimensional tests
4000: For complete chemical test
1500: For complete qualitative and other finish tests |
| Cl 5(DIMENSIONS AND TOLERANCES) |
- |
11500 |
|
- |
| Cl 5(DIMENSIONS AND TOLERANCES) |
- |
11500 |
|
- |
| Cl 5(DIMENSIONS AND TOLERANCES) |
- |
11500 |
|
- |
| Cl 5(DIMENSIONS AND TOLERANCES) |
- |
11500 |
|
- |
| Cl 5(DIMENSIONS AND TOLERANCES) |
- |
11500 |
|
- |
| Cl 5(DIMENSIONS AND TOLERANCES) |
- |
11500 |
|
- |
| Cl 5(DIMENSIONS AND TOLERANCES) |
- |
11500 |
|
- |
| Cl 6(MANUFACTURE) |
- |
11500 |
|
- |
| Cl 7(FINISH) |
- |
11500 |
|
- |
| 5(DIMENSIONS AND TOLERANCES) |
- |
11500 |
|
- |
| 5(DIMENSIONS AND TOLERANCES) |
- |
11500 |
|
- |
| 5(DIMENSIONS AND TOLERANCES) |
- |
11500 |
|
- |
| 5(DIMENSIONS AND TOLERANCES) |
- |
11500 |
|
- |
| 5(DIMENSIONS AND TOLERANCES) |
- |
11500 |
|
- |
| 5(DIMENSIONS AND TOLERANCES) |
- |
11500 |
|
- |
| 5(DIMENSIONS AND TOLERANCES) |
- |
11500 |
|
- |
| 5(DIMENSIONS AND TOLERANCES) |
- |
11500 |
|
- |
| 5(DIMENSIONS AND TOLERANCES) |
- |
11500 |
|
- |
| 5(DIMENSIONS AND TOLERANCES) |
- |
11500 |
|
- |
| 5(DIMENSIONS AND TOLERANCES) |
- |
11500 |
|
- |
| 5(DIMENSIONS AND TOLERANCES) |
- |
11500 |
|
- |
| 5(DIMENSIONS AND TOLERANCES) |
- |
11500 |
|
- |
| 5(DIMENSIONS AND TOLERANCES) |
- |
11500 |
|
- |
| 5(DIMENSIONS AND TOLERANCES) |
- |
11500 |
|
- |
| 5(DIMENSIONS AND TOLERANCES) |
- |
11500 |
|
- |
| 5(DIMENSIONS AND TOLERANCES) |
- |
11500 |
|
- |
| 5(DIMENSIONS AND TOLERANCES) |
- |
11500 |
|
- |
| 5(DIMENSIONS AND TOLERANCES) |
- |
11500 |
|
- |
| 5(DIMENSIONS AND TOLERANCES) |
- |
11500 |
|
- |
| 6(MANUFACTURE) |
- |
11500 |
|
- |
| 7(FINISH) |
- |
11500 |
|
- |
| 8(Marking) |
- |
11500 |
|
- |
| 8(Marking) |
- |
11500 |
|
- |
| Cl.4(Carbon) |
- |
11500 |
|
- |
| Cl.4(Sulphur) |
- |
11500 |
|
- |
| Cl.4(Phosphorus) |
- |
11500 |
|
- |
| Cl.4(Manganese) |
- |
11500 |
|
- |
| Cl.4(Silicon) |
- |
11500 |
|
- |
| Cl.4(Nickel) |
- |
11500 |
|
- |
| Cl.4(Chromium) |
- |
11500 |
|
- |
| Cl.4(Copper) |
- |
11500 |
|
- |
| Cl.4(Molybdenum) |
- |
11500 |
|
- |
| Cl.4(Nitrogen) |
- |
11500 |
|
- |
| Cl.4(Titanium) |
- |
11500 |
|
- |
| Cl.4(Niobium) |
- |
11500 |
|
- |
| Sub-Clause. 10.3.1(Dimension) |
- |
11500 |
|
- |
| Sub-Clause. 10.3.2(Tensile test) |
- |
11500 |
|
- |
| Sub-Clause. 10.3.3(corrosion resistance) |
- |
11500 |
|
- |
|
- |
- included w.e.f 16.03.2026 |
| 1220 |
Eco Paryavaran Laboratories and Consultants Pvt. Ltd.
| 9198906
| IS 303 (2024) |
Plywood for General Purposes â Specification (Fourth Revision) |
Grade: MR/BWR/BWP Formaldehyde Class- E1 & E2 (All grade, size, type as per IS) |
13000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl-5.1(Classification by appearance) |
- |
100 |
|
- |
| Cl-5.2, Table- 1 (i)(Blister) |
- |
100 |
|
- |
| Cl-5.2, Table- 1 (ii)(Checks) |
- |
100 |
|
- |
| Cl-5.2, Table- 1 (iii)(Discolouration) |
- |
100 |
|
- |
| Cl-5.2, Table- 1 (iv)(Dote) |
- |
100 |
|
- |
| Cl-5.2, Table- 1 (v)(Insect hole) |
- |
100 |
|
- |
| Cl-5.2, Table- 1 (vi)(Joints) |
- |
100 |
|
- |
| Cl-5.2, Table- 1 (vii)(Knots (dead)) |
- |
100 |
|
- |
| Cl-5.2, Table- 1 (viii)(Pin knots (dead)) |
- |
100 |
|
- |
| Cl-5.2, Table- 1 (ix)(Pin knots (live)) |
- |
100 |
|
- |
| Cl-5.2, Table- 1 (x)(Knots (tight)) |
- |
100 |
|
- |
| Cl-5.2, Table- 1 (xi)(Patches) |
- |
100 |
|
- |
| Cl-5.2, Table- 1 (xii)(Splits) |
- |
100 |
|
- |
| Cl-5.2, Table- 1 (xiii)(Swirl) |
- |
100 |
|
- |
| Cl-5.2, Table-2(Maximum Number of Categories of Permissible Defects, per m2) |
- |
100 |
|
- |
| Cl-6.1(Timber) |
- |
5500 |
|
- |
| Cl-6.2(Adhesive) |
- |
5500 |
|
- |
| Cl-7.2.1(Thickness of veneers) |
- |
200 |
|
- |
| Cl-7.2.3(Grain Direction) |
- |
100 |
|
- |
| Cl-7.2.5.1(Gaps in cores and cross-bands) |
- |
100 |
|
- |
| Cl-7.2.5.2(Splits) |
- |
100 |
|
- |
| Cl-7.2.5.3(Overlap) |
- |
100 |
|
- |
| Cl-8.1(Dimensions -length) |
- |
200 |
|
- |
| Cl-8.2(Thickness of the plywood boards) |
- |
200 |
|
- |
| Cl-8.3(Squareness) |
- |
200 |
|
- |
| Cl-11.3.1, 11.3.1.1(Water Resistance Test) |
- |
1000 |
|
- |
| Cl-11.3.2(Mycological Test) |
- |
1500 |
|
- |
| Cl-11.4(Moisture Content) |
- |
1000 |
|
- |
| Cl-11.5, Table 4(Static Bending Strength - Modulus of Elasticity - Along the Face Grain - Average) |
- |
1500 |
|
- |
| Cl-11.5, Table 4(Static Bending Strength - Modulus of Elasticity - Along the Face Grain - Minimum Individual) |
- |
1500 |
|
- |
| Cl-11.6(Formaldehyde Content Test) |
- |
3500 |
|
- |
| Cl-9(WORKMANSHIP AND FINISH) |
- |
500 |
|
- |
| Cl-7.2.4(Scarf Joints) |
- |
100 |
|
- |
| Cl. 4(Grades) |
- |
100 |
|
- |
| Cl.5.1(Type based on classification by appearance) |
- |
100 |
|
- |
| Cl.5.2(Quality Requirements of Plywood for General Purposes) |
- |
500 |
|
- |
| Cl.8.1(Dimensions -width) |
- |
200 |
|
- |
| Cl.8, 8.3 & Annex C(Edge Straightness) |
- |
200 |
|
- |
| Cl.8, 8.3 & Annex C(Edge Squareness) |
- |
200 |
|
- |
| Cl-11.5, Table-4(Static Bending Strength - Modulus of Elasticity - Across the Face Grain - Average) |
- |
1500 |
|
- |
| Cl-11.5, Table-4,(Static Bending Strength - Modulus of Elasticity - Across the Face Grain - Minimum Individual) |
- |
1500 |
|
- |
| Cl-8.3(Edge Straightness) |
- |
200 |
|
- |
| Cl-11.5, Table-4(Static Bending Strength - Modulus of Rupture - Along the Face Grain - Average) |
- |
1500 |
|
- |
| Cl-11.5, Table-4(Static Bending Strength - Modulus of Rupture - Along the Face Grain - Minimum Individual) |
- |
1500 |
|
- |
| Cl-11.5, Table-4(Static Bending Strength - Modulus of Rupture - Across the Face Grain - Average) |
- |
1500 |
|
- |
| Cl-11.5, Table-4(Static Bending Strength - Modulus of Rupture - Across the Face Grain - Minimum Individual) |
- |
1500 |
|
- |
| Cl-13(Marking) |
- |
200 |
|
- |
|
11 Aug, 2029 |
- Exclusion: Cl-11.7 (Steady-State Formaldehyde Emission Test) (Optional Test) |
| 1221 |
JBS TESTING SOLUTIONS PVT LTD (27), JALANDHAR
| 9164606
| IS 12817 (2020) |
Stainless Steel Butt Hinges - Specification ( Third Revision ) |
- |
10000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 6.2, Table 1 to 6(Length , A -IS 12817) |
- |
10000 |
|
* 4500 for complete dimensional and other mechanical tests
* 4000 for complete chemical tests
* 1500 for other qualitative and finish tests |
| 6.2, Table 1 to 6(Breadth, B-IS 12817) |
- |
10000 |
|
* 4500 for complete dimensional and other mechanical tests
* 4000 for complete chemical tests
* 1500 for other qualitative and finish tests |
| 6.2, Table 1 to 6(Breadth, B1-IS 12817) |
- |
10000 |
|
* 4500 for complete dimensional and other mechanical tests
* 4000 for complete chemical tests
* 1500 for other qualitative and finish tests |
| 6.2, Table 1 to 6(Breadth, B2-IS 12817) |
- |
10000 |
|
* 4500 for complete dimensional and other mechanical tests
* 4000 for complete chemical tests
* 1500 for other qualitative and finish tests |
| 6.2, Table 1 to 6(Thickness of flap, C-IS 12817) |
- |
10000 |
|
* 4500 for complete dimensional and other mechanical tests
* 4000 for complete chemical tests
* 1500 for other qualitative and finish tests |
| 6.2, Table 1 to 6(Dia. of Hinge pin, D-IS 12817 ) |
- |
10000 |
|
* 4500 for complete dimensional and other mechanical tests
* 4000 for complete chemical tests
* 1500 for other qualitative and finish tests |
| 6.2, Table 1 to 6(Number of Knuckles- IS 12817 ) |
- |
10000 |
|
* 4500 for complete dimensional and other mechanical tests
* 4000 for complete chemical tests
* 1500 for other qualitative and finish tests |
| 6.2, Table 1 to 6(Number of Screw Holes -IS 12817 ) |
- |
10000 |
|
* 4500 for complete dimensional and other mechanical tests
* 4000 for complete chemical tests
* 1500 for other qualitative and finish tests |
| 6.2, Table 1 to 6(Holes for Screw Number- IS 12817 ) |
- |
10000 |
|
* 4500 for complete dimensional and other mechanical tests
* 4000 for complete chemical tests
* 1500 for other qualitative and finish tests |
| 7.1(General - IS 12817 ) |
- |
10000 |
|
* 4500 for complete dimensional and other mechanical tests
* 4000 for complete chemical tests
* 1500 for other qualitative and finish tests |
| 7.2(Knuckles - IS 12817 ) |
- |
10000 |
|
* 4500 for complete dimensional and other mechanical tests
* 4000 for complete chemical tests
* 1500 for other qualitative and finish tests |
| 7.3(Pins- IS 12817 ) |
- |
10000 |
|
* 4500 for complete dimensional and other mechanical tests
* 4000 for complete chemical tests
* 1500 for other qualitative and finish tests |
| 7.4(Screw Holes- IS 12817 ) |
- |
10000 |
|
- |
| 7.4.2(Position of screw holes - IS 12817 ) |
- |
10000 |
|
- |
| 7.4.2, Fig 1(The distance of the screw holes from the end of the flap - IS 12817 ) |
- |
10000 |
|
- |
| 8.0(Finish - IS 12817 ) |
- |
10000 |
|
- |
| Clause 4.1.2(Silicon (Pin) ) |
- |
10000 |
|
- |
| Clause 4.1.2(Phosphorus (Pin) ) |
- |
10000 |
|
- |
| Clause 4.1.2(Sulphur (Pin) ) |
- |
10000 |
|
- |
| Clause 4.1.2(Manganese (Pin) ) |
- |
10000 |
|
- |
| Clause 4.1.2(Carbon (Pin) ) |
- |
10000 |
|
- |
| Clause 4.1.1(Silicon (Flap) ) |
- |
10000 |
|
- |
| Clause 4.1.1(Phosphorus (Flap) ) |
- |
10000 |
|
- |
| Clause 4.1.1(Sulphur (Flap) ) |
- |
10000 |
|
- |
| Clause 4.1.1(Manganese (Flap) ) |
- |
10000 |
|
- |
| Clause 4.1.1(Carbon (Flap) ) |
- |
10000 |
|
- |
| Clause 7.4.2 (Dimension - Z ) |
- |
10000 |
|
- |
| Clause 7.4.2 (Dimension - Y ) |
- |
10000 |
|
- |
| Clause 7.4.2 (Dimension - X ) |
- |
10000 |
|
- |
| Clause 7.4.1(Number of holes) |
- |
10000 |
|
- |
| As per Cl.4(Carbon) |
- |
10000 |
|
- |
| As per Cl.4(Sulphur) |
- |
10000 |
|
- |
| As per Cl.4(Phosphorus) |
- |
10000 |
|
- |
| As per Cl.4(Manganese) |
- |
10000 |
|
- |
| As per Cl.4(Nitrogen) |
- |
10000 |
|
- |
| As per Cl.4(Silicon) |
- |
10000 |
|
- |
| As per Cl.4(Aluminium) |
- |
10000 |
|
- |
| As per Cl.4(Chromium) |
- |
10000 |
|
- |
| As per Cl.4(Vanadium) |
- |
10000 |
|
- |
| As per Cl.4(Molybdenum) |
- |
10000 |
|
- |
| As per Cl.4(Niobium) |
- |
10000 |
|
- |
| As per Cl.4(Nickel) |
- |
10000 |
|
- |
| As per Cl.4(Copper) |
- |
10000 |
|
- |
| As per Cl.4(Titanium) |
- |
10000 |
|
- |
| As per Cl.4(Zirconium) |
- |
10000 |
|
- |
| As per Cl.4(Tungsten) |
- |
10000 |
|
- |
| As per Cl.4(Cerium) |
- |
10000 |
|
- |
| Cl.4(Other Elements - IS 228 and its parts or any other intrumental/chemical methods) |
- |
10000 |
|
- |
|
- |
- included w.e.f 16.03.2026 |
| 1222 |
Stellar Test House, Noida
| 8171606
| IS 302 : PART 1 (Cooking Ranges, Hobs, Ovens and Similar Appliances) |
Cooking Ranges, Hobs, Ovens and Similar Appliances |
- |
30000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 5(General condition for the tests) |
- |
500 |
|
- |
| 4(General Requirements) |
- |
500 |
|
- |
| 32.0(Radiation, Toxicity and Similar hazards) |
- |
1000 |
|
- |
| 31.0(Resistance to rusting) |
- |
1000 |
|
- |
| 30.0(Resistance to heat and fire) |
- |
1000 |
|
- |
| 29.0(Clearances and Creepage distances and solid insulation) |
- |
1000 |
|
- |
| 28.0(Screws and connections) |
- |
1000 |
|
- |
| 27.0(Provision for Earthing) |
- |
1000 |
|
- |
| 26.0(Terminal for External Conductors) |
- |
1000 |
|
- |
| 25.0(Supply connections and External Flexible Cords) |
- |
1000 |
|
- |
| 24.0(Components) |
- |
1000 |
|
- |
| 23.0(Internal wiring) |
- |
1000 |
|
- |
| 22.0(Construction verification related tests) |
- |
1000 |
|
- |
| 21.0(Mechanical Strength) |
- |
1000 |
|
- |
| 20.0(Stability and Mechanical Hazards) |
- |
1000 |
|
- |
| 19.0(Abnormal Operations) |
- |
1000 |
|
- |
| 18.0(Endurance test) |
- |
1000 |
|
- |
| 17.0(Overload protection of transformers test) |
- |
1000 |
|
- |
| 16.0(Leakage current and electric strength test) |
- |
1000 |
|
- |
| 15.0(Moisture Resistance) |
- |
1000 |
|
- |
| 14.0(Transient voltages) |
- |
1000 |
|
- |
| 13.0(Leakage current and electric strength test) |
- |
1000 |
|
- |
| 11.0(Heating test) |
- |
1000 |
|
- |
| 10.0(Power Input and current test) |
- |
1000 |
|
- |
| 9.0(Starting of motor-operated appliances test) |
- |
1000 |
|
- |
| 8.0(Protection against access to live part test) |
- |
1000 |
|
- |
| 7.0(Marking and instructions) |
- |
500 |
|
- |
| 6.0(Classification) |
- |
500 |
|
- |
|
26 Sep, 2028 |
- Included w.e.f. 18.06.2026
19.11.4.7 (Harmonics)
19.11.4.6 (Class 3 Voltage dips and interruptions)
19.11.4.5 (Immunity to conducted discharges)
19.11.4.4 (Surge immunity test)
19.11.4.3 (Fast transient bursts)
19.11.4.2 (Radiated fields)
19.11.4.1 (Electrostatic discharges)" |
| 1223 |
JBS TESTING SOLUTIONS PVT LTD (27), JALANDHAR
| 9164606
| IS 15833 (2009) |
Stainless Steel Tower Bolts -specification |
- |
7500 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Clause 4.2(Carbon Content) |
- |
7500 |
|
2000 For complete Dimensional tests
4000: For Complete chemical tests
1500: For other qualitative tests and finish |
| Clause 4.2(Silicon) |
- |
7500 |
|
2000 For complete Dimensional tests
4000: For Complete chemical tests
1500: For other qualitative tests and finish |
| Clause 4.2(Manganese) |
- |
7500 |
|
- |
| Clause 4.2(nickel) |
- |
7500 |
|
- |
| Clause 4.2(Chromium) |
- |
7500 |
|
- |
| Clause 4.2(Sulphur) |
- |
7500 |
|
- |
| Clause 4.2(Phosphorus) |
- |
7500 |
|
- |
| Clause 4.2(Carbon Content) |
- |
7500 |
|
- |
| Clause 4.2(Silicon) |
- |
7500 |
|
- |
| Clause 4.2(Manganese) |
- |
7500 |
|
- |
| Clause 4.2(nickel) |
- |
7500 |
|
- |
| Clause 4.2(Chromium) |
- |
7500 |
|
- |
| Clause 4.2(Sulphur) |
- |
7500 |
|
- |
| Clause 4.2(Phosphorus) |
- |
7500 |
|
- |
| Clause 4.2(Mech)(Phosphorus) |
- |
7500 |
|
- |
| Clause 4.2(Mech)(Sulphur) |
- |
7500 |
|
- |
| Clause 4.2(Mech)(Chromium) |
- |
7500 |
|
- |
| Clause 4.2(Mech)(nickel) |
- |
7500 |
|
- |
| Clause 4.2(Mech)(Silicon) |
- |
7500 |
|
- |
| Clause 4.2(Mech)(Carbon Content) |
- |
7500 |
|
- |
| Cl 7(0) |
- |
7500 |
|
- |
| Cl 6(DIMENSIONS) |
- |
7500 |
|
- |
| Cl 6(DIMENSIONS) |
- |
7500 |
|
- |
| Cl 6(DIMENSIONS) |
- |
7500 |
|
- |
| Cl 6(DIMENSIONS) |
- |
7500 |
|
- |
| Cl 6(DIMENSIONS) |
- |
7500 |
|
- |
| Cl 6(DIMENSIONS) |
- |
7500 |
|
- |
| Cl 6(DIMENSIONS) |
- |
7500 |
|
- |
| Cl 6(DIMENSIONS) |
- |
7500 |
|
- |
| Cl 6(DIMENSIONS) |
- |
7500 |
|
- |
| Cl 6(DIMENSIONS) |
- |
7500 |
|
- |
| Cl 5(MANUFACTURE) |
- |
7500 |
|
- |
| Cl 4(MATERIAL) |
- |
7500 |
|
- |
| Cl 3(NOMINAL SIZES) |
- |
7500 |
|
- |
| Cl 3(NOMINAL SIZES) |
- |
7500 |
|
- |
| 8(Marking) |
- |
7500 |
|
- |
| Clause 4.2(Mech)(Manganese) |
- |
7500 |
|
- |
|
- |
- included w.e.f 16.03.2026 |
| 1224 |
Atckon Laboratories LLP, Bahadurgarh
| 8186436
| IS 18480 (2025) |
Self-Tapping Screws - Specification (first revision) |
ALL SIZES |
19000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Clause. 4.0(Dimension.) |
- |
2000 |
|
- |
| Clause. 4.0(Thread size.) |
- |
2000 |
|
- |
| Clause. 4.0(Length) |
- |
2000 |
|
- |
| Clause.5.0(Dimenssions.) |
- |
2000 |
|
- |
| Clause.6.1(Steel drilling screws) |
- |
5000 |
|
- |
| Clause. 6.2(Stainless steel Drilling Screws) |
- |
5000 |
|
- |
| Clause. 7.0(Threads) |
- |
2000 |
|
- |
| Clause. 8.0(Tolerance) |
- |
2000 |
|
- |
| Clause 9.0(Finish(coating)) |
- |
5000 |
|
- |
| Clause.10(Designation) |
- |
500 |
|
- |
| Clause.10(Marking) |
- |
500 |
|
- |
|
- |
- Included w.e.f. 16.03.2026 |
| 1225 |
JBS TESTING SOLUTIONS PVT LTD (27), JALANDHAR
| 9164606
| IS 4985 (2021) |
UNPLASTICIZED PVC PIPES FOR POTABLE WATER SUPPLIES SPECIFICATION Fourth Revision |
-- |
25500 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 10.1(Colour) |
- |
500 |
|
- |
| 10.1(Surface Finish) |
- |
0 |
|
- |
| 7.2.1.1 Table3(Angle of taper (Note-1)) |
- |
500 |
|
- |
| 10.7(Sulphated Ash Content) |
- |
3000 |
|
- |
| 5(CLASSIFICATION OF PIPES) |
- |
0 |
|
- |
| Cl-7.1(Mean out side Diameter (For less than or equal to 40 mm- Average of 8 , For higher diameters up to 110 mm average of 6)) |
- |
1000 |
|
- |
| 7.1.1.1(DIMENSIONS-PIPE-Mean O.D. (Minimum)) |
- |
1000 |
|
- |
| 7.1.1.1(DIMENSIONS-PIPE-Mean O.D. (Mamimum)) |
- |
1000 |
|
- |
| 7.1.1.1(DIMENSIONS-PIPE-Mean O.D. Variation) |
- |
1000 |
|
- |
| 7.1.1.2(DIMENSIONS-PIPE-O.D. at any Point (Minimum)) |
- |
1000 |
|
- |
| 7.1.1.2(DIMENSIONS-PIPE-O.D. at any Point (Maximum)) |
- |
1000 |
|
- |
| 7.1.1.2(DIMENSIONS-PIPE-Ovality (Maximum)) |
- |
1000 |
|
- |
| 7.1.2.1(DIMENSIONS-PIPE-Thickness(Minimum)) |
- |
1000 |
|
- |
| 7.1.2.1(DIMENSIONS-PIPE-Thickness(Maximum)) |
- |
1000 |
|
- |
| 7.1.2.1(DIMENSIONS-PIPE-Average Thickness) |
- |
1000 |
|
- |
| Cl- 7.2(Socket length (Take 4 reading & minimum will be reported)) |
- |
1000 |
|
- |
| 7.2.1(DIMENSIONS-Socket) |
- |
1000 |
|
- |
| 7.2.1.1-Table 3(DIMENSIONS-Socket-Sockets for solvent cement jointing-Minimum Length) |
- |
1000 |
|
- |
| 7.2.1.1-Table 3(DIMENSIONS-Socket-Sockets for solvent cement jointing-Diameter at mid point of the socket length (Minimum)) |
- |
1000 |
|
- |
| 7.2.1.1-Table 3(DIMENSIONS-Socket-Sockets for solvent cement jointing-Diameter at mid point of the socket length (Maximum)) |
- |
1000 |
|
- |
| 7.2.1.2(a)-Table 5(DIMENSIONS-Sockets for elastomeric sealing ring joints-Minimum depth of engagement) |
- |
1000 |
|
- |
| 7.2.1.2-Table 4(DIMENSIONS-Sockets for elastomeric sealing ring joints-Socket inner Diameter) |
- |
1000 |
|
- |
| 8(SEALING RINGS) |
- |
1000 |
|
- |
| 9.1(PIPE ENDS) |
- |
1000 |
|
- |
| 10.1(PHYSICAL AND CHEMICAL CHARACTERISTICS-Visual Appearance) |
- |
500 |
|
- |
| 10.1.1(PHYSICAL AND CHEMICAL CHARACTERISTICS-Visual Appearance) |
- |
500 |
|
- |
| 10.2(PHYSICAL AND CHEMICAL CHARACTERISTICS-Opacity) |
- |
500 |
|
- |
| 10.4(PHYSICAL AND CHEMICAL CHARACTERISTICS- Reversion Test) |
- |
500 |
|
- |
| 10.5(PHYSICAL AND CHEMICAL CHARACTERISTICS- Vicat Softening Temperature) |
- |
500 |
|
- |
| 10.6(PHYSICAL AND CHEMICAL CHARACTERISTICS- Density) |
- |
500 |
|
- |
| 11.1-Table 6(MECHANICAL PROPERTIES-Hydrostatic Pressure Test (Type Test)) |
- |
15000 |
|
- |
| 11.1-Table 6(MECHANICAL PROPERTIES-Hydrostatic Pressure Test (Acceptance Test)) |
- |
10000 |
|
- |
| 11.1-Table 7(MECHANICAL PROPERTIES-Hydrostatic Pressure Test (Type Test)-for Integral Sealing Ring Sockets) |
- |
2000 |
|
- |
| 11.1-Table 7(MECHANICAL PROPERTIES-Hydrostatic Pressure Test (Acceptance Test)-for Integral Sealing Ring Sockets) |
- |
10000 |
|
- |
| 11.1.1(MECHANICAL PROPERTIES-Hydrostatic Pressure Test (Acceptance Test)-for Plumbing pipes) |
- |
10000 |
|
- |
| 11.2(Resistance to External Blows at 0°C) |
- |
5000 |
|
- |
| 10.3(Effect on Water Test) |
- |
6500 |
|
- |
| 6.1.2(PVC Resin) |
- |
4000 |
|
- |
| 7.1.3(mean outside diameter, outside diameter at
any point, and wall thickness of plumbing pipes) |
- |
1000 |
|
- |
| 7.1.4(Length) |
- |
1000 |
|
- |
| 6.1.1(VCM Content) |
- |
5000 |
|
- |
| 7.2.1.2b(Maximum inner diameter of groove) |
- |
1000 |
|
- |
| 13.1(Marking) |
- |
300 |
|
- |
| cL-13.1.1(Marking) |
- |
300 |
|
- |
| Cl-13.1.2(Marking) |
- |
300 |
|
- |
| Cl-10.3 (i)(Effect on Lead (first extraction)) |
- |
7500 |
|
- |
| Cl-10.3 (ii)(Effect on Lead (third extraction)) |
- |
7500 |
|
- |
| Cl-10.3 (iii)(Effect on Dialkyl tin C4 and higher homologues measured as tin (third extraction)) |
- |
7500 |
|
- |
| Cl-10.3 (iv)(Effect on Cadmium) |
- |
7500 |
|
- |
| Cl-10.3 (v)(Effect on Mercury) |
- |
7500 |
|
- |
| Cl-10.3 (vi)(Other toxic substances such as ‘di-n-octyl-tin- mass) s-s bis iso-octyl mercapto acetate’ and ‘butyl stearate) |
- |
7500 |
|
- |
| Cl-7.1(Outside Diameter at any point (Take 8 reading reported minimum, maximum)) |
- |
1000 |
|
- |
| CL 7.1(Wall thickness "Average,minimum,maximum" (Take 8 reading)) |
- |
1000 |
|
- |
|
- |
- included w.e.f 16.03.2026 |
| 1226 |
QUALITY INTERNATIONAL RESEARCH & LABORATORIES PRIVATE LIMITED
| 5197006
| IS 1239 : Part 1 (2004) |
Steel Tubes, Tubulars and Other Wrought Steel Fittings : Part 1 Steel Tubes (BI-LINGUAL) |
Steel Tubes Light / Medium / Heavy |
17500 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 12 AND AS PER IS 4736(UNIFORMITY OF ZINC COATING) |
- |
500 |
|
- |
| 12 AND AS PER IS 4736(MASS OF ZINC COATING) |
- |
500 |
|
- |
| 6.2 AND AS PER IS 513(NITROGEN) |
- |
2500 |
|
- |
| 6.2 AND AS PER IS 513(MICRO ALLOY) |
- |
2500 |
|
- |
| 6.2 AND AS PER IS 513(ALUMINIUM) |
- |
500 |
|
- |
| 6.2 AND AS PER IS 513(SILICON) |
- |
500 |
|
- |
| 6.2 AND AS PER IS 513(MANGANESE) |
- |
500 |
|
- |
| 6.2 AND AS PER IS 513(PHOSPHORUS) |
- |
500 |
|
- |
| 6.2 AND AS PER IS 513(SULPHUR) |
- |
500 |
|
- |
| 6.2 AND AS PER IS 513(CARBON) |
- |
500 |
|
- |
| 6.2 AND AS PER IS 10748(COPPER) |
- |
500 |
|
- |
| 6.2 AND AS PER IS 10748(NITROGEN) |
- |
2500 |
|
- |
| 6.2 AND AS PER IS 10748(MICRO ALLOY) |
- |
2500 |
|
- |
| 6.2 AND AS PER IS 10748(ALUMINIUM) |
- |
500 |
|
- |
| 6.2 AND AS PER IS 10748(SILICON) |
- |
500 |
|
- |
| 6.2 AND AS PER IS 10748(CARBON EQUIVALENT) |
- |
500 |
|
- |
| 6.2 AND AS PER IS 10748(MANGANESE) |
- |
500 |
|
- |
| 6.2 AND AS PER IS 10748(PHOSPHORUS) |
- |
500 |
|
- |
| 6.2 AND AS PER IS 10748(SULPHUR) |
- |
500 |
|
- |
| 6.2 AND AS PER IS 10748(CARBON) |
- |
500 |
|
- |
| Clause - 6.1.1, Table-1( ALUMINIUM) |
- |
500 |
|
- |
| Clause - 6.1.1, Table-1(SILICON) |
- |
500 |
|
- |
| Clause - 6.1.1, Table-1(NITROGEN) |
- |
2500 |
|
- |
| Clause - 6.1.1, Table-1(MANGANESE) |
- |
500 |
|
- |
| Clause - 6.1.1, Table-1(PHOSPHURS) |
- |
500 |
|
- |
| Clause - 6.1.1, Table-1(SULPHUR) |
- |
500 |
|
- |
| Clause - 6.1.1, Table-1( CARBON) |
- |
500 |
|
- |
| 12 AND AS PER IS 4736(UNIFORMITY OF ZINC COATING) |
- |
1000 |
|
- |
| 12 AND AS PER IS 4736(MASS OF ZINC COATING) |
- |
1000 |
|
- |
| 6.2 AND AS PER IS 513(NITROGEN) |
- |
2500 |
|
- |
| 6.2 AND AS PER IS 513(MICRO ALLOY) |
- |
2500 |
|
- |
| 6.2 AND AS PER IS 513(ALUMINIUM) |
- |
500 |
|
- |
| 6.2 AND AS PER IS 513(SILICON) |
- |
500 |
|
- |
| 6.2 AND AS PER IS 513(MANGANESE) |
- |
500 |
|
- |
| 6.2 AND AS PER IS 513(PHOSPHORUS) |
- |
500 |
|
- |
| 6.2 AND AS PER IS 513(SULPHUR) |
- |
500 |
|
- |
| 6.2 AND AS PER IS 513(CARBON) |
- |
500 |
|
- |
| 6.2 AND AS PER IS 10748(COPPER) |
- |
500 |
|
- |
| 6.2 AND AS PER IS 10748(NITROGEN) |
- |
2500 |
|
- |
| 6.2 AND AS PER IS 10748(MICRO ALLOY) |
- |
2500 |
|
- |
| 6.2 AND AS PER IS 10748(ALUMINIUM) |
- |
500 |
|
- |
| 6.2 AND AS PER IS 10748(SILICON) |
- |
500 |
|
- |
| 6.2 AND AS PER IS 10748(CARBON EQUIVALENT) |
- |
500 |
|
- |
| 6.2 AND AS PER IS 10748(MANGANESE) |
- |
500 |
|
- |
| 6.2 AND AS PER IS 10748(PHOSPHORUS) |
- |
500 |
|
- |
| 6.2 AND AS PER IS 10748(SULPHUR) |
- |
500 |
|
- |
| 6.2 AND AS PER IS 10748(CARBON) |
- |
500 |
|
- |
| 6.1.1(MANGANESE) |
- |
500 |
|
- |
| 6.1.1(PHOSPHORUS) |
- |
500 |
|
- |
| 6.1.1(SULPHUR) |
- |
500 |
|
- |
| 6.1.1(CARBON) |
- |
500 |
|
- |
| Cl. 6.1.1, table1 of IS 1239(Part1)(Phosphorus- IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
500 |
|
- |
| Cl. 6.1.1, table1 of IS 1239(Part1)(Sulphur- IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
500 |
|
- |
| Cl. 6.1.1, table1 of IS 1239(Part1)(Manganese- IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
500 |
|
- |
| Cl. 6.1.1, table1 of IS 1239(Part1)(Carbon- IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
500 |
|
- |
| Cl. 15(Workmanship) |
- |
500 |
|
- |
| Cl. 14.3(Flattening test (Over 50 mm NB)) |
- |
1000 |
|
- |
| Cl. 14.2(Bend Test (uto and including 50 mm NB)) |
- |
1000 |
|
- |
| Cl. 14.1.1(Elongation) |
- |
1000 |
|
- |
| Cl. 14.1(Tensile Strength) |
- |
1000 |
|
- |
| Cl. 3.3, 10.2(Plain End) |
- |
500 |
|
- |
| Cl. 11(Length) |
- |
500 |
|
- |
| Cl. 8, 9 Table 3,4 & 5(Mass of Tube) |
- |
500 |
|
- |
| Cl. 6.5(Height of Internal Fin) |
- |
500 |
|
- |
| Cl. 8, 9 Table 3,4 & 5(Thickness) |
- |
500 |
|
- |
| Cl. 8 Table 3,4 & 5(Outside Diameter) |
- |
500 |
|
- |
| Clause 14.1.1(Elongation Percent) |
- |
1000 |
|
- |
| Clause 11.3(Approximate Length) |
- |
500 |
|
- |
| Clause 11.2(Exact Length) |
- |
500 |
|
- |
| Clause 11.1(Random Length) |
- |
500 |
|
- |
| Clause 8.1 (Table3,4,5)(Nominal Bore ) |
- |
500 |
|
- |
| Cl 15(Workmanship) |
- |
500 |
|
- |
| Cl 14(Tensile Test, Flattening Test & Bend Test) |
- |
2500 |
|
- |
| Cl 12(Workmanship) |
- |
500 |
|
- |
| Cl 10.1.1(Manufacturing ) |
- |
500 |
|
- |
| Cl 10.1(Manufacturing ) |
- |
500 |
|
- |
| Cl 8(Outer Diameter, Thickness & Mass) |
- |
500 |
|
- |
| 17(Marking) |
- |
500 |
|
- |
| cl.17(MARKING) |
- |
500 |
|
- |
| 6.2(Carbon Equivalent as CE- IS:8811-98(RA12)) |
- |
500 |
|
- |
| CL 08 & 09("1.Outer dia (04)
2.Thickness (08)") |
- |
500 |
|
- |
| CL 08 & 09(Minimum Outer dia (04)) |
- |
500 |
|
- |
| CL 08 & 09("
Minimum Thickness (08)") |
- |
500 |
|
- |
| CL 08 & 09(Maximum Thickness (08)) |
- |
500 |
|
- |
| CL 08 & 09(Maximum Outer dia (04)) |
- |
500 |
|
- |
|
- |
- Included w.e.f 16.03.2026 |
| 1227 |
The Man Made Textile Research Association, Surat
| 7179304
| IS 17261 (2022) |
Textiles - Polyester continuous filament fully drawn yarns - Specification (first revision) |
- |
50500 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 5(Designation ( IS 17261)) |
- |
50500 |
|
20,500 INR - For White Yarn
25,500 INR - For Coloured Yarn
50,500 INR - With ECO-Mark Requirements |
| 6.1 & Table-3(Linear Density) |
- |
50500 |
|
20,500 INR - For White Yarn
25,500 INR - For Coloured Yarn
50,500 INR - With ECO-Mark Requirements |
| 6.1 & Table-3(Uneveness U) |
- |
50500 |
|
20,500 INR - For White Yarn
25,500 INR - For Coloured Yarn
50,500 INR - With ECO-Mark Requirements |
| 6.1 & Table-3(Tenacity) |
- |
50500 |
|
20,500 INR - For White Yarn
25,500 INR - For Coloured Yarn
50,500 INR - With ECO-Mark Requirements |
| 6.1 & Table-3(Elongation) |
- |
50500 |
|
20,500 INR - For White Yarn
25,500 INR - For Coloured Yarn
50,500 INR - With ECO-Mark Requirements |
| 6.2 & Table-4(Moisture regain ( IS17261)) |
- |
50500 |
|
20,500 INR - For White Yarn
25,500 INR - For Coloured Yarn
50,500 INR - With ECO-Mark Requirements |
| 6.2 & Table-4(Isophthalic acid (IPA) content (IS 16481)) |
- |
50500 |
|
20,500 INR - For White Yarn
25,500 INR - For Coloured Yarn
50,500 INR - With ECO-Mark Requirements |
| 6.2 & Table-4(Water soluble matter (IS 3456)) |
- |
50500 |
|
20,500 INR - For White Yarn
25,500 INR - For Coloured Yarn
50,500 INR - With ECO-Mark Requirements |
| 6.2 & Table-4(Finish oil pick-up ( IS17261)) |
- |
50500 |
|
20,500 INR - For White Yarn
25,500 INR - For Coloured Yarn
50,500 INR - With ECO-Mark Requirements |
| 6.2 & Table-4(Phosphorus content ( IS17261)) |
- |
50500 |
|
20,500 INR - For White Yarn
25,500 INR - For Coloured Yarn
50,500 INR - With ECO-Mark Requirements |
| 6.2 & Table-4(Colour strength with reference to standard yarn ( IS17261)) |
- |
50500 |
|
20,500 INR - For White Yarn
25,500 INR - For Coloured Yarn
50,500 INR - With ECO-Mark Requirements |
| 6.2 & Table-4(Colour difference with reference to standard yarn, measured as ΔE ( IS17261)) |
- |
50500 |
|
20,500 INR - For White Yarn
25,500 INR - For Coloured Yarn
50,500 INR - With ECO-Mark Requirements |
| 6.3(Freedom From Defects) |
- |
50500 |
|
20,500 INR - For White Yarn
25,500 INR - For Coloured Yarn
50,500 INR - With ECO-Mark Requirements |
| 6.4 & Table-5(Lustre/Brightness TiO2 Content) |
- |
50500 |
|
20,500 INR - For White Yarn
25,500 INR - For Coloured Yarn
50,500 INR - With ECO-Mark Requirements |
| 6.5 & Table-7(Colour Fastness Rating To Washing Change in colour) |
- |
50500 |
|
20,500 INR - For White Yarn
25,500 INR - For Coloured Yarn
50,500 INR - With ECO-Mark Requirements |
| 6.5 & Table-8(Colour Fastness Rating To Washing Staining) |
- |
50500 |
|
20,500 INR - For White Yarn
25,500 INR - For Coloured Yarn
50,500 INR - With ECO-Mark Requirements |
| 6.5 & Table-9(Colour Fastness Rating To Rubbing Dry) |
- |
50500 |
|
20,500 INR - For White Yarn
25,500 INR - For Coloured Yarn
50,500 INR - With ECO-Mark Requirements |
| 6.5 & Table-10(Colour Fastness Rating To Rubbing Wet) |
- |
50500 |
|
20,500 INR - For White Yarn
25,500 INR - For Coloured Yarn
50,500 INR - With ECO-Mark Requirements |
| 6.5 & Table-11(Colour Fastness Rating To Perspiration (acidic and alkaline) Change in colour) |
- |
50500 |
|
20,500 INR - For White Yarn
25,500 INR - For Coloured Yarn
50,500 INR - With ECO-Mark Requirements |
| 6.5 & Table-12(Colour Fastness Rating To Perspiration (acidic and alkaline) Staining) |
- |
50500 |
|
20,500 INR - For White Yarn
25,500 INR - For Coloured Yarn
50,500 INR - With ECO-Mark Requirements |
| 6.7 & table-7(Free and releasable formaldehyde) |
- |
50500 |
|
20,500 INR - For White Yarn
25,500 INR - For Coloured Yarn
50,500 INR - With ECO-Mark Requirements |
| 6.7 & table-7(Mercury (IS 15651)) |
- |
50500 |
|
20,500 INR - For White Yarn
25,500 INR - For Coloured Yarn
50,500 INR - With ECO-Mark Requirements |
| 6.7 & table-7(Chromium III (IS 15651)) |
- |
50500 |
|
20,500 INR - For White Yarn
25,500 INR - For Coloured Yarn
50,500 INR - With ECO-Mark Requirements |
| 6.7 & table-7(Chromium VI (IS 15651)) |
- |
50500 |
|
20,500 INR - For White Yarn
25,500 INR - For Coloured Yarn
50,500 INR - With ECO-Mark Requirements |
| 6.7 & table-7(Lead (IS 15651)) |
- |
50500 |
|
20,500 INR - For White Yarn
25,500 INR - For Coloured Yarn
50,500 INR - With ECO-Mark Requirements |
| 6.7 & table-7(Cadmium (IS 15651)) |
- |
50500 |
|
20,500 INR - For White Yarn
25,500 INR - For Coloured Yarn
50,500 INR - With ECO-Mark Requirements |
| 6.7 & table-7(Copper (IS 15651)) |
- |
50500 |
|
20,500 INR - For White Yarn
25,500 INR - For Coloured Yarn
50,500 INR - With ECO-Mark Requirements |
| 6.7 & table-7(Antimony (IS 15651)) |
- |
50500 |
|
20,500 INR - For White Yarn
25,500 INR - For Coloured Yarn
50,500 INR - With ECO-Mark Requirements |
| 6.7 & table-7(Pentachlorophenol (IS 15651)) |
- |
50500 |
|
20,500 INR - For White Yarn
25,500 INR - For Coloured Yarn
50,500 INR - With ECO-Mark Requirements |
| 6.7 & table-7(Pesticides (IS 15651)) |
- |
50500 |
|
20,500 INR - For White Yarn
25,500 INR - For Coloured Yarn
50,500 INR - With ECO-Mark Requirements |
| 6.7 & table-7(Banned Pesticides (IS 15651)) |
- |
50500 |
|
20,500 INR - For White Yarn
25,500 INR - For Coloured Yarn
50,500 INR - With ECO-Mark Requirements |
| 6.7 & table-7(Banned azo colourants (arylamines) (IS 15570)) |
- |
50500 |
|
20,500 INR - For White Yarn
25,500 INR - For Coloured Yarn
50,500 INR - With ECO-Mark Requirements |
| 8(Marking (IS 17261)) |
- |
50500 |
|
20,500 INR - For White Yarn
25,500 INR - For Coloured Yarn
50,500 INR - With ECO-Mark Requirements |
| 6.7 & Table 7(Colour Fastness Rating To Light Change in colour (IS/ISO 105-B01 or IS/ISO 105-B02)) |
- |
0.01 |
|
FACILITIES NOT AVAILABLE |
| 5.2(Identification and Description, Annex J of IS 16481 & IS 667) |
- |
50500 |
|
20,500 INR - For White Yarn
25,500 INR - For Coloured Yarn
50,500 INR - With ECO-Mark Requirements |
| 6.1 Table -3(Interlace as nips per metre, Annex B of IS 17262) |
- |
50500 |
|
20,500 INR - For White Yarn
25,500 INR - For Coloured Yarn
50,500 INR - With ECO-Mark Requirements |
| 6.1 Table -3(No. of filaments in multifilament yarn) |
- |
50500 |
|
20,500 INR - For White Yarn
25,500 INR - For Coloured Yarn
50,500 INR - With ECO-Mark Requirements |
| 6.2- Table -4, Sl no. 2 (a)(Isophthalic acid (IPA) content in Virgin polyester yarn, Percent, Annex C of IS 16481) |
- |
50500 |
|
20,500 INR - For White Yarn
25,500 INR - For Coloured Yarn
50,500 INR - With ECO-Mark Requirements |
| 6.2- Table -4, Sl no. 2 (b)(Isophthalic acid (IPA) content in Dope dyed/white yarn, Percent, Annex C of IS 16482) |
- |
50500 |
|
20,500 INR - For White Yarn
25,500 INR - For Coloured Yarn
50,500 INR - With ECO-Mark Requirements |
| 6.2- Table -4, Sl no. 2 (c)(Isophthalic acid (IPA) content in Recycled polyester yarn, Percent, Annex C of IS 16483) |
- |
50500 |
|
20,500 INR - For White Yarn
25,500 INR - For Coloured Yarn
50,500 INR - With ECO-Mark Requirements |
| 6.6(Commercial Mass, IS 7703) |
- |
50500 |
|
20,500 INR - For White Yarn
25,500 INR - For Coloured Yarn
50,500 INR - With ECO-Mark Requirements |
| 6.5 Table 6(Colour Fastness to Light) |
- |
0.01 |
|
FACLITIES NOT AVAILABLE |
| 6.5 Table 6(Colour Fatness to Washing, Test 2) |
- |
50500 |
|
20,500 INR - For White Yarn
25,500 INR - For Coloured Yarn
50,500 INR - With ECO-Mark Requirements |
| 6.5 Table 6(Colour Fastness to Rubbing) |
- |
50500 |
|
20,500 INR - For White Yarn
25,500 INR - For Coloured Yarn
50,500 INR - With ECO-Mark Requirements |
| 6.5 Table 6(Colour Fastness to perspiration) |
- |
50000 |
|
20,000 INR - For White Yarn
25,000 INR - For Coloured Yarn
50,000 INR - With ECO-Mark Requirements |
| 6.2 Table 4(Moisture Regain , %) |
- |
50000 |
|
20,000 INR - For White Yarn
25,000 INR - For Coloured Yarn
50,000 INR - With ECO-Mark Requirements |
| 6.2 Table 4(Water soluble matter %) |
- |
50000 |
|
20,000 INR - For White Yarn
25,000 INR - For Coloured Yarn
50,000 INR - With ECO-Mark Requirements |
| 6.2 Table 4(Finish oil pickup, %) |
- |
50000 |
|
20,000 INR - For White Yarn
25,000 INR - For Coloured Yarn
50,000 INR - With ECO-Mark Requirements |
| 6.2 Table 4(Phosphorus content , %) |
- |
50000 |
|
20,000 INR - For White Yarn
25,000 INR - For Coloured Yarn
50,000 INR - With ECO-Mark Requirements |
| 6.2 Table 4(Phosphorus content , %) |
- |
50000 |
|
20,000 INR - For White Yarn
25,000 INR - For Coloured Yarn
50,000 INR - With ECO-Mark Requirements |
| 6.2 Table 4(Colour strength with refernce to standard yarn, %) |
- |
50000 |
|
20,000 INR - For White Yarn
25,000 INR - For Coloured Yarn
50,000 INR - With ECO-Mark Requirements |
| 6.2 Table 4(Colour difference with referece standard yarn, measure as DE) |
- |
50000 |
|
20,000 INR - For White Yarn
25,000 INR - For Coloured Yarn
50,000 INR - With ECO-Mark Requirements |
| 6.1 Table 3(Linear Density ,Denier (dtex)) |
- |
50000 |
|
20,000 INR - For White Yarn
25,000 INR - For Coloured Yarn
50,000 INR - With ECO-Mark Requirements |
| 6.1 Table 3(Unevenness ,(U %)) |
- |
50000 |
|
20,000 INR - For White Yarn
25,000 INR - For Coloured Yarn
50,000 INR - With ECO-Mark Requirements |
| 6.1 Table 3(Tenacity,gpd (cN/dtex)) |
- |
50000 |
|
20,000 INR - For White Yarn
25,000 INR - For Coloured Yarn
50,000 INR - With ECO-Mark Requirements |
| 6.1 Table 3(Elongation %) |
- |
50000 |
|
20,000 INR - For White Yarn
25,000 INR - For Coloured Yarn
50,000 INR - With ECO-Mark Requirements |
| 6.1 Table 3(Boiling Water Shrinkage %) |
- |
50000 |
|
20,000 INR - For White Yarn
25,000 INR - For Coloured Yarn
50,000 INR - With ECO-Mark Requirements |
| 4(Classification (IS 17261)) |
- |
50000 |
|
CROSS SECTION + CROSS SECTION AREA
20,000 INR - For White Yarn
25,000 INR - For Coloured Yarn
50,000 INR - With ECO-Mark Requirements |
| Cl-6.1, Table-3, Notes-4 (Amendment No.7)(Twist) |
- |
- |
|
- |
|
- |
- - |
| 1228 |
QUALITY INTERNATIONAL RESEARCH & LABORATORIES PRIVATE LIMITED
| 5197006
| IS 10773 (2025) |
Wrought copper tubes for refrigeration and air-conditioning purposes Specification (Second Revision) |
Wrought Copper Tubes of Grade Cu-DLP & Cu-DHP |
13500 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Clause. No.5.0(Chemical composition) |
- |
1000 |
|
- |
| Clause. No.5.0(Copper + Silver) |
- |
2000 |
|
- |
| Clause. No.5.0(phophrous) |
- |
500 |
|
- |
| Clause no.6.0(Manufacturer) |
- |
500 |
|
- |
| Clause no.7.0(Freedom from defects) |
- |
500 |
|
- |
| Clause no.8.0(Mechnical and properties.) |
- |
2500 |
|
- |
| Clause no.9.0(Dimension and tolerance.) |
- |
1000 |
|
- |
| Clause no.10(Non destructive test.) |
- |
1000 |
|
- |
| Clause.no.11.0(Residue test or Cleanliness test.) |
- |
500 |
|
- |
| Clause.no.11.0(Marking) |
- |
500 |
|
- |
| Clause no.10.2(Hydrostatic Test) |
- |
1000 |
|
- |
| Clause no.10.3("Pneumatic Test
") |
- |
10000 |
|
- |
| Clause no.10.4(Microscopic Examination) |
- |
1000 |
|
- |
| Clause. No.5.0(Chemical composition) |
- |
2500 |
|
- |
| Clause. No.5.0(Copper + Silver) |
- |
1000 |
|
- |
| Clause. No.5.0(phophrous) |
- |
1000 |
|
- |
| Clause no.6.0(Manufacturer) |
- |
500 |
|
- |
| Clause no.7.0(Freedom from defects) |
- |
500 |
|
- |
| Clause no.8.0(Mechnical and properties.) |
- |
2500 |
|
- |
| Clause no.9.0(Dimension and tolerance.) |
- |
500 |
|
- |
| Clause no.10(Non destructive test.) |
- |
1000 |
|
- |
| Clause.no.11.0(Residue test or Cleanliness test.) |
- |
1000 |
|
- |
| Clause.no.11.0(Marking) |
- |
500 |
|
- |
| Clause no.10.2(Hydrostatic Test) |
- |
1000 |
|
- |
| Clause no.10.3("Pneumatic Test
") |
- |
1000 |
|
- |
| Clause no.10.4(Microscopic Examination) |
- |
1000 |
|
- |
|
- |
- Included w.e.f 16.03.2026
Exclusion: "Clause. No.5.0 (Oxygen)
Clause no.10.1 (Eddy-Current Test)
Clause no.10.5 (Hydrogen Embrittlement Test)" |
| 1229 |
JBS TESTING SOLUTIONS PVT LTD (27), JALANDHAR
| 9164606
| IS 15683 (2018) |
Portable Fire Extinguishers — Performance and Construction — Specification ( First Revision ) |
- |
300000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl. 5.3.1(Filling Requirements) |
- |
300000 |
|
Total Mechanical & Chemical test except Composite Cylinders for Plastic Body Test & Fire Tests For BC Powder Type - Rs. 48,300.00 ABC Powder Type – Rs. 49,500.00 D Powder Type - Rs. 47,100.00 Foam Type Rs 55,500.00 Water Type - Rs. 54,300.00 |
| Cl. 5.3.2(Filling Requirements) |
- |
300000 |
|
Water mist Type- Rs. 84,300.00 F Class Type - Rs. 54,300.00 Clean Agent Type-Rs. 47,700.00 CO2 Type - Rs. 31,300.00 |
| Cl. 5.3.2(Filling Requirements) |
- |
300000 |
|
Details testing charges of fire tests and electrical conductivity of extinguisher discharge test are as follows: For A Class Fire Test (Cl.8.3) 1A-Rs. 17,000/- 2A-Rs. 19,000/- 3A-Rs. 21,000/- 4A-Rs. 30,000/- 6A-Rs. 35,000/- 10A A-Rs. 52,500/- |
| Cl. 5.3.2(Filling Requirements) |
- |
300000 |
|
15A-Rs. 70,000/- 20A-Rs. 95,000/- For B Class Fire Test (Cl.8.4) 8B-Rs. 9,000/- 13B-Rs. 11,000/- 21B-Rs. 13,000/- 34B-Rs. 30,000/- 55B-Rs. 40,000/- 70B-Rs. 45,000/- 89B-Rs. 55,000/- 113B-Rs. 60,000/- 144B-Rs. 65,000/- 183B-Rs. 75,000/- 233B-Rs. 85,000/- |
| Cl. 5.3.2(Filling Requirements) |
- |
300000 |
|
or D Class Ext.(Cl.8.5) Rs. 15,000/- For F Class Fire Tests (Cl.8.6 & 8.7) For 5F-Rs. 12,000/- For 15F-Rs. 16,500/- For 25F-Rs. 30,000/- For 75F-Rs. 45,000/- For electrical conductivity of extinguisher discharge (C1.8.8)- Rs.30,000/- |
| Cl. 5.3.2(Filling Requirements) |
- |
300000 |
|
For composite cylinders (Cl.9.2.8)- Rs. 6,000/- For pressure gauge (Cl.9.11)- Rs.8,000/- |
| Cl. 5.3.2(Filling Requirements) |
- |
300000 |
|
- |
| Cl. 5.3.3(Capacities) |
- |
300000 |
|
- |
| Cl. 5.3.3(Capacities) |
- |
300000 |
|
- |
| Cl. 5.3.3(Capacities) |
- |
300000 |
|
- |
| Cl. 5.3.3(Capacities) |
- |
300000 |
|
- |
| Cl. 5.3.3(Capacities) |
- |
300000 |
|
- |
| Cl. 5.3.3(Capacities) |
- |
300000 |
|
- |
| Cl. 6(PRESSURE REQUIREMENTS FOR LOW PRESSURE EXTINGUISHERS) |
- |
300000 |
|
- |
| Cl. 6(PRESSURE REQUIREMENTS FOR LOW PRESSURE EXTINGUISHERS) |
- |
300000 |
|
- |
| Cl. 7.1(GENERAL OPERATING PERFORMANCE REQUIREMENTS) |
- |
300000 |
|
- |
| Cl. 7.2 - Table 1(GENERAL OPERATING PERFORMANCE REQUIREMENTS) |
- |
300000 |
|
- |
| Cl. 7.2 - Table 1(GENERAL OPERATING PERFORMANCE REQUIREMENTS) |
- |
300000 |
|
- |
| Cl. 7.3(Resistance to Temperature changes) |
- |
300000 |
|
- |
| Cl 7.4.3( Leakage Test) |
- |
300000 |
|
- |
| Cl 7.5.1(Impact Resistance Test) |
- |
300000 |
|
- |
| Cl 7.5.2(Vibration Resistance Test) |
- |
300000 |
|
- |
| Cl 7.6(Resistance to Corrosion) |
- |
300000 |
|
- |
| Cl 7.7(Tapping Test) |
- |
300000 |
|
- |
| Cl 7.8(Intermittent Discharge Test) |
- |
300000 |
|
- |
| Cl 7.8(Intermittent Discharge Test) |
- |
300000 |
|
- |
| Cl 8.1(Rating Suitability for the Various Classes of Fire) |
- |
300000 |
|
- |
| Cl 8.6(Electrical Conductivity of Extinguisher Discharge) |
- |
300000 |
|
- |
| Cl 9(CONSTRUCTION REQUIREMENTS) |
- |
300000 |
|
- |
| Cl 9.2.2(Burst Test) |
- |
300000 |
|
- |
| Cl 9.2.3(Crushing Test) |
- |
300000 |
|
- |
| Cl 9.2.4(Pressure Cycling Test) |
- |
300000 |
|
- |
| Cl 9.2.5(Welded Low Carbon Steel Cylinder) |
- |
300000 |
|
- |
| Cl 9.2.6(Stainless Steel Cylinders) |
- |
300000 |
|
- |
| Cl 9.2.7(Aluminium Cylinders) |
- |
300000 |
|
- |
| Cl 9.3(Carrying Handle) |
- |
300000 |
|
- |
| Cl 9.4(Mounting) |
- |
300000 |
|
- |
| Cl 9.5(Caps, Valves and Closures) |
- |
300000 |
|
- |
| Cl 9.7.1(Requirements for Plastics Components) |
- |
300000 |
|
- |
| Cl 9.7.2(Requirements for Plastics Components) |
- |
300000 |
|
- |
| Cl 9.7.3(Requirements for Plastics Components) |
- |
300000 |
|
- |
| Cl 9.8(Hose Assemblies) |
- |
300000 |
|
- |
| Cl 9.8(Hose Assemblies) |
- |
300000 |
|
- |
| Cl 9.9 - Table 10(Method of Operation) |
- |
300000 |
|
- |
| Cl 9.10(Safety-Locking Devices) |
- |
300000 |
|
- |
| Cl 9.11.1(Requirements for Pressure Gauges and Indicators for Low-Pressure Extinguishers) |
- |
300000 |
|
- |
| Cl 9.11.2(Calibration Test - Gauges and Indicators) |
- |
300000 |
|
- |
| Cl 9.11.3(Burst Strength Test — Gauges and Indicators) |
- |
300000 |
|
- |
| Cl 9.11.4(Water Resistance Test — Gauges and Indicators) |
- |
300000 |
|
- |
| Cl 9.12(Dip-Tubes and Filters — Water-Based Extinguishers) |
- |
300000 |
|
- |
| Cl 9.13(Horn Test for Carbon Dioxide (CO2) Extinguishers) |
- |
300000 |
|
- |
| Cl 9.14(Requirements for Extinguishants Filled in the Extinguisher) |
- |
300000 |
|
- |
| Cl 10(MARKING AND COLOUR) |
- |
300000 |
|
- |
| 9.6(Safety Device) |
- |
300000 |
|
- |
| 9.2.8(Composite Cylinder) |
- |
300000 |
|
- |
| 9.2.7(Measure Thickness of the cylinder (Aluminium body)) |
- |
300000 |
|
- |
| 9.2.6.3 (Measure Thickness of the cylinder (S.S. Body)) |
- |
300000 |
|
- |
| 9.2.6.1 & 9.2.6.2 (Carbon composition of stainless steel cylinder) |
- |
300000 |
|
- |
| 9.2.5.3, (Measure Thickness of the cylinder) |
- |
300000 |
|
- |
| 9.2.5.1 & 9.2.5.2(Composition of welded low carbon steel cylinders) |
- |
300000 |
|
- |
| 9.2.1.7(Construction requirement for the bottom of the extinguisher) |
- |
300000 |
|
- |
| 9.2.1.6(Type of threads on parts made of plastic component joining metal parts) |
- |
300000 |
|
- |
| 9.2.1.5(Cast Analysis Certifcate) |
- |
300000 |
|
- |
| 9.2.1.4(Construction requirement of Neck Ring) |
- |
300000 |
|
- |
| 9.2.1.3(Requirement of Welding) |
- |
300000 |
|
- |
| 9.2.1.2(Construction requirement for stand vertically upright position) |
- |
300000 |
|
- |
| 9.1(General Requirements of High Pressure Extinguisher) |
- |
300000 |
|
- |
| 8.8(Electrical Conductivity of Extinguishers Discharge ) |
- |
300000 |
|
- |
| 8.1.5, 8.2.2(C) , 8.6, 8.7(Class F Splash Test) |
- |
300000 |
|
- |
| 8.1.4 & 8.5(Class D Test fire) |
- |
300000 |
|
- |
| 8.1.2, 8.2.2 b) & 8.4(Class B Fire Test) |
- |
300000 |
|
- |
| 8.1.1, 8.2.2 a) & 8.3(Class A Fire Test) |
- |
300000 |
|
- |
| 7.6.1(Internal Corrosion Test Test is applicable only for water based & clean agent PFEs) |
- |
300000 |
|
- |
| 7.6.1(External Corrosion Test for all types of extinguishers) |
- |
300000 |
|
- |
| 7.4.2(Leakage Test) |
- |
300000 |
|
- |
| 7.4.1.(Retention of charge following partial discharge) |
- |
300000 |
|
- |
| 6.2(Determination of Minimum Burst Pressure) |
- |
300000 |
|
- |
| 6.1(Determination of Test Pressure) |
- |
300000 |
|
- |
| 3.6 & 9.2.1.8(Determination of Maximum Service Pressure ) |
- |
300000 |
|
- |
| 3.5 & 9.2.1.1(Determination of Service Pressure ) |
- |
300000 |
|
- |
| 7.6.2(Internal Corrosion Test for Extinguishers Using Water-Based Medium and Clean Agent) |
- |
300000 |
|
- |
| 9.14.1(Content of Mono Ammonium Phosphate) |
- |
300000 |
|
- |
| 9.14.2(Content of Sodium Bicarbonate/Potassium Picarbonate for BC Powder) |
- |
300000 |
|
- |
| 9.14.3(Surface Tension of Foam Solution) |
- |
300000 |
|
- |
| 9.8.2(Requirement of hose and coupling system) |
- |
300000 |
|
- |
| 9.8.3("Requirement of Burst Pressure of Hose fitted with shut-off nozzle
") |
- |
300000 |
|
- |
| 9.8.3("Requirement of Burst Pressure of Hose fitted with shut-off nozzle
for CO2 Fire Extinguisher") |
- |
300000 |
|
- |
| 9.8.4(A hose assembly without a shut-off nozzle shall be capable of withstanding, without leakage, a pressure equal to the extinguisher test pressure i.e Max (1.43 × Pms , 35 bar) held for at least 30 seconds.) |
- |
300000 |
|
- |
| 9.10.3, 9.10.4, 9.10.5 & 9.10.6(Requirement of safety-locking pin or other device) |
- |
300000 |
|
- |
| 9.10.2(Requirement of safety device material) |
- |
300000 |
|
- |
|
- |
- included w.e.f 16.03.2026 |
| 1230 |
Stellar Test House, Noida
| 8171606
| IS 302 : PART 1 (Commercial Electric Cooking Ranges, Ovens, Hobs and Hob Elements) |
Commercial Electric Cooking Ranges, Ovens, Hobs and Hob Elements |
- |
30000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 6(Classifications) |
- |
500 |
|
- |
| 5(General conditions for tests) |
- |
500 |
|
- |
| 4(General Requirement) |
- |
500 |
|
- |
| 11.8(Temperature rise) |
- |
1000 |
|
- |
| 11.7(Duration corresponding) |
- |
1000 |
|
- |
| 11.6(Combined appliances) |
- |
1000 |
|
- |
| 11.5(Motor-operated appliances) |
- |
1000 |
|
- |
| 11.4(Heating appliances) |
- |
1000 |
|
- |
| 8.1.5(Live parts of built-in appliances) |
- |
1000 |
|
- |
| 18(Endurance) |
- |
1000 |
|
- |
| 17(Overload protection of transformers and associated circuits) |
- |
1000 |
|
- |
| 16(Leakage current and electric strength) |
- |
1000 |
|
- |
| 4(General requirement) |
- |
500 |
|
- |
| 32(Radiation Toxicity and Similar Hazards) |
- |
1000 |
|
- |
| 31(Resistance to Rusting) |
- |
1000 |
|
- |
| 30.2(Needle Flame Test) |
- |
1000 |
|
- |
| 30.2(Glow Wire Test) |
- |
1000 |
|
- |
| 30.1(Ball pressure test) |
- |
1000 |
|
- |
| 29(clearance, creepage distances and solid insulation) |
- |
1000 |
|
- |
| 28(Screw test and connections) |
- |
1000 |
|
- |
| 27(Provision for earthing) |
- |
1000 |
|
- |
| 26(Terminals for external conductors) |
- |
1000 |
|
- |
| 25(Supply connection and external flexible cords) |
- |
1000 |
|
- |
| 24(Components) |
- |
1000 |
|
- |
| 23(General) |
- |
1000 |
|
- |
| 22(Construction verification related test) |
- |
1000 |
|
- |
| 21(Mechanical Strength Test) |
- |
1000 |
|
- |
| 20(Stability test) |
- |
1000 |
|
- |
| 19(Abnormal Operation) |
- |
1000 |
|
- |
| 18(Endurance Test requirements and tests) |
- |
1000 |
|
- |
| 17(Over Load Protection of Transformers and associated circuits) |
- |
1000 |
|
- |
| 16.3(Electric Strength (after clause 15 and 16.2)) |
- |
1000 |
|
- |
| 16.2(Leakage Current (after Clause 15)) |
- |
1000 |
|
- |
| 16.1(General) |
- |
1000 |
|
- |
| 16.0(General) |
- |
1000 |
|
- |
| 15.3(Humidity Test) |
- |
1000 |
|
- |
| 15.2(Spillage Test) |
- |
1000 |
|
- |
| 15.1(Ingress Protection test other than IPX0 (IP test)) |
- |
1000 |
|
- |
| 15.0(General) |
- |
1000 |
|
- |
| 14(Transient Over Voltages) |
- |
1000 |
|
- |
| 13.3(Electric Strength at operating temperature) |
- |
1000 |
|
- |
| 13.3(Electric Strength at operating temperature) |
- |
1000 |
|
- |
| 13.2(Leakage current at operating temperature) |
- |
1000 |
|
- |
| 13.1(General) |
- |
1000 |
|
- |
| 11.3(Heating) |
- |
1000 |
|
- |
| 11.2(General) |
- |
1000 |
|
- |
| 11.1(General) |
- |
1000 |
|
- |
| 10.2(Current input) |
- |
1000 |
|
- |
| 10.1(Power input) |
- |
1000 |
|
- |
| 9(Starting of motor operation test requirements and tests) |
- |
1000 |
|
- |
| 8.1.4(Protection against live parts against protective impedance) |
- |
1000 |
|
- |
| 8.1.3(Protection against live parts in visible glowing heating elements) |
- |
1000 |
|
- |
| 8.1.2(Protection against live parts in openings) |
- |
1000 |
|
- |
| 8.1.1(Protection against live parts in all positions) |
- |
1000 |
|
- |
| 7(Marking and instructions) |
- |
500 |
|
- |
|
26 Sep, 2028 |
- Included w.e.f. 18.06.2026
19.11.4.7 (Harmonics)
19.11.4.6 (Class 3 Voltage dips and interruptions)
19.11.4.5 (Immunity to conducted discharges)
19.11.4.4 (Surge immunity test)
19.11.4.3 (Fast transient bursts)
19.11.4.2 (Radiated fields)
19.11.4.1 (Electrostatic discharges)" |