| 1261 |
Intertek India Private Limited, New Delhi (E-26)
| 8136626
| IS 18112 (2025) |
DIGITAL TELEVISION RECEIVER FOR SATELLITE BROADCAST TRANSMISSION SPECIFICATION (First Revision) |
- |
318000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Clause 4.4, Table-2, ii)(RF characteristics to be supported by the DTV receiver) |
- |
10000 |
|
10% discount offered to samples received from BIS. |
| Clause 4.3(Specifications) |
- |
5000 |
|
10% discount offered to samples received from BIS. |
| Clause 4.5(Safety Requirements) |
- |
126000 |
|
10% discount offered to samples received from BIS. |
| Clause 5(Marking) |
- |
2000 |
|
10% discount offered to samples received from BIS. |
| Clause 6(Operating Life Test) |
- |
20000 |
|
10% discount offered to samples received from BIS. |
| Clause 4.1, Table-1, i) a)(Hardware specification) |
- |
3000 |
|
10% discount offered to samples received from BIS. |
| Clause 4.1, Table-1, i) b)(Decompression and decoding of SDTV video) |
- |
5000 |
|
10% discount offered to samples received from BIS. |
| Clause 4.1, Table-1, i) c)(Decompression and decoding of HDTV video) |
- |
5000 |
|
10% discount offered to samples received from BIS. |
| Clause 4.1, Table-1, i) d)(Decompression and decoding of audio) |
- |
5000 |
|
10% discount offered to samples received from BIS. |
| Clause 4.1, Table-1, i) e)(Active Format descriptors) |
- |
5000 |
|
10% discount offered to samples received from BIS. |
| Clause 4.1, Table-1, i) f)(Captioning and Sub-titling) |
- |
5000 |
|
10% discount offered to samples received from BIS. |
| Clause 4.1, Table-1, i) g)(Teletext) |
- |
2000 |
|
10% discount offered to samples received from BIS. |
| Clause 4.1, Table-1, i) h)(Multi-language support) |
- |
2000 |
|
10% discount offered to samples received from BIS. |
| Clause 4.1, Table-1, i) j)(DTV receiver mixed Audio Description) |
- |
5000 |
|
10% discount offered to samples received from BIS. |
| Clause 4.1, Table-1, i) k)(Broadcast mixed audio description) |
- |
5000 |
|
10% discount offered to samples received from BIS. |
| Clause 4.1, Table-1, i) m)(Service demultiplexing) |
- |
5000 |
|
10% discount offered to samples received from BIS. |
| Clause 4.1, Table-1, i) n)(Data services) |
- |
5000 |
|
10% discount offered to samples received from BIS. |
| Clause 4.1, Table-1, i) p)(OSD) |
- |
5000 |
|
10% discount offered to samples received from BIS. |
| Clause 4.1, Table-1, i) q)(DTV character set) |
- |
5000 |
|
10% discount offered to samples received from BIS. |
| Clause 4.1, Table-1, i) r)(Electronic Service Guide (ESG) ‘Now/Next’) |
- |
5000 |
|
10% discount offered to samples received from BIS. |
| Clause 4.1, Table-1, i) s)(Time) |
- |
1000 |
|
10% discount offered to samples received from BIS. |
| Clause 4.1, Table-1, i) t)(Digital TV output) |
- |
2000 |
|
10% discount offered to samples received from BIS. |
| Clause 4.4, Table-2, i) b)(Frequency) |
- |
1000 |
|
10% discount offered to samples received from BIS. |
| Clause 4.4, Table-2, i) a)(Input voltage range) |
- |
1000 |
|
10% discount offered to samples received from BIS. |
| Clause 4.1,Table-1, ii) a)(Demodulation and FEC decoding) |
- |
5000 |
|
10% discount offered to samples received from BIS. |
| Clause 4.1, Table-1, ii) b)(DTV Receiver Installation) |
- |
2000 |
|
10% discount offered to samples received from BIS. |
| Clause 4.1, Table-1, ii) c)(Network evolution) |
- |
2000 |
|
10% discount offered to samples received from BIS. |
| Clause 4.4, Table-2, iii) c)(RF input impedance) |
- |
5000 |
|
10% discount offered to samples received from BIS. |
| Clause 4.1, Table-1, ii) d)(Services available) |
- |
2000 |
|
10% discount offered to samples received from BIS. |
| Clause 4.1, Table-1, ii) e)(Selection via Service List) |
- |
2000 |
|
10% discount offered to samples received from BIS. |
| Clause 4.1, Table-1, ii) f)(Selection via Numeric Entry) |
- |
2000 |
|
10% discount offered to samples received from BIS. |
| Clause 4.1, Table-1, ii) g)(Favourite Channel list) |
- |
1000 |
|
10% discount offered to samples received from BIS. |
| Clause 4.1, Table-1, ii) h)(Hidden Services) |
- |
2000 |
|
10% discount offered to samples received from BIS. |
| Clause 4.4, Table-2, iii) b)(Input frequency range) |
- |
5000 |
|
10% discount offered to samples received from BIS. |
| Clause 4.1, Table-1, ii) j)(Logical Channel Number for Satellite services) |
- |
2000 |
|
10% discount offered to samples received from BIS. |
| Clause 4.1, Table-1, ii) k)(RF input signal) |
- |
3000 |
|
10% discount offered to samples received from BIS. |
| Clause 4.1, Table-1, ii) m)(LNB supply current) |
- |
5000 |
|
10% discount offered to samples received from BIS. |
| Clause 4.1, Table-1, ii) n)(LNB supply voltage) |
- |
3000 |
|
10% discount offered to samples received from BIS. |
| Clause 4.1, Table-1, ii) p)(LNB Control) |
- |
2000 |
|
10% discount offered to samples received from BIS. |
| Clause 4.1, Table-1, ii) q)(Modulation/Demodulation parameters for DVB-S & DVB-S2 standard) |
- |
2000 |
|
10% discount offered to samples received from BIS. |
| Clause 4.4, Table-2, iii) a)(Input level per carrier) |
- |
5000 |
|
10% discount offered to samples received from BIS. |
| Clause 4.4, Table-2, iv) c)(RF input impedance) |
- |
5000 |
|
10% discount offered to samples received from BIS. |
| Clause 4.4, Table-2, iv) b)(Input frequency range) |
- |
5000 |
|
10% discount offered to samples received from BIS. |
| Clause 4.4, Table-2, iv) a)(Input level per carrier) |
- |
5000 |
|
10% discount offered to samples received from BIS. |
| Clause 4.4, Table-2, v)(Symbol rate) |
- |
5000 |
|
10% discount offered to samples received from BIS. |
| Clause 4.4, Table-2, vi)(RF input return loss) |
- |
5000 |
|
10% discount offered to samples received from BIS. |
| Clause 4.4, Table-2, vii)(DisEqC) |
- |
2000 |
|
10% discount offered to samples received from BIS. |
| Clause 4.4, Table-2, viii)(Operating ambient temperature range) |
- |
1000 |
|
10% discount offered to samples received from BIS. |
| Clause 4.4, Table-2, ix)(Operating humidity range) |
- |
1000 |
|
10% discount offered to samples received from BIS. |
| Clause 4.1, Table-1, iii) a)(Interfaces, Connectors) |
- |
1000 |
|
10% discount offered to samples received from BIS. |
| Clause 4.1, Table-1, iv)(Automatic software upgrade mechanism) |
- |
1000 |
|
10% discount offered to samples received from BIS. |
| Clause 4.1, Table-1, v) a)(Remote Control) |
- |
1000 |
|
10% discount offered to samples received from BIS. |
| Clause 4.1, Table-1, v) b)(Easy to use and simple documentation) |
- |
1000 |
|
10% discount offered to samples received from BIS. |
| Clause 3.1, Table-1, v) c)(Support package) |
- |
1000 |
|
10% discount offered to samples received from BIS. |
| Clause 4.4, Table-2, ii)(RF characteristics to be supported by the DTV receiver) |
- |
- |
|
- |
| Clause 4.3(Specifications) |
- |
- |
|
- |
| Clause 4.5(Safety Requirements) |
- |
- |
|
- |
| Clause 5(Marking) |
- |
- |
|
- |
| Clause 6(Operating Life Test) |
- |
- |
|
- |
| Clause 4.1, Table-1, i) a)(Hardware specification) |
- |
- |
|
- |
| Clause 4.1, Table-1, i) b)(Decompression and decoding of SDTV video) |
- |
- |
|
- |
| Clause 4.1, Table-1, i) c)(Decompression and decoding of HDTV video) |
- |
- |
|
- |
| Clause 4.1, Table-1, i) d)(Decompression and decoding of audio) |
- |
- |
|
- |
| Clause 4.1, Table-1, i) e)(Active Format descriptors) |
- |
- |
|
- |
| Clause 4.1, Table-1, i) f)(Captioning and Sub-titling) |
- |
- |
|
- |
| Clause 4.1, Table-1, i) g)(Teletext) |
- |
- |
|
- |
| Clause 4.1, Table-1, i) h)(Multi-language support) |
- |
- |
|
- |
| Clause 4.1, Table-1, i) j)(DTV receiver mixed Audio Description) |
- |
- |
|
- |
| Clause 4.1, Table-1, i) k)(Broadcast mixed audio description) |
- |
- |
|
- |
| Clause 4.1, Table-1, i) m)(Service demultiplexing) |
- |
- |
|
- |
| Clause 4.1, Table-1, i) n)(Data services) |
- |
- |
|
- |
| Clause 4.1, Table-1, i) p)(OSD) |
- |
- |
|
- |
| Clause 4.1, Table-1, i) q)(DTV character set) |
- |
- |
|
- |
| Clause 4.1, Table-1, i) r)(Electronic Service Guide (ESG) ‘Now/Next’) |
- |
- |
|
- |
| Clause 4.1, Table-1, i) s)(Time) |
- |
- |
|
- |
| Clause 4.1, Table-1, i) t)(Digital TV output) |
- |
- |
|
- |
| Clause 4.4, Table-2, i) b)(Frequency) |
- |
- |
|
- |
| Clause 4.4, Table-2, i) a)(Input voltage range) |
- |
- |
|
- |
| Clause 4.1,Table-1, ii) a)(Demodulation and FEC decoding) |
- |
- |
|
- |
| Clause 4.1, Table-1, ii) b)(DTV Receiver Installation) |
- |
- |
|
- |
| Clause 4.1, Table-1, ii) c)(Network evolution) |
- |
- |
|
- |
| Clause 4.4, Table-2, iii) c)(RF input impedance) |
- |
- |
|
- |
| Clause 4.1, Table-1, ii) d)(Services available) |
- |
- |
|
- |
| Clause 4.1, Table-1, ii) e)(Selection via Service List) |
- |
- |
|
- |
| Clause 4.1, Table-1, ii) f)(Selection via Numeric Entry) |
- |
- |
|
- |
| Clause 4.1, Table-1, ii) g)(Favourite Channel list) |
- |
- |
|
- |
| Clause 4.1, Table-1, ii) h)(Hidden Services) |
- |
- |
|
- |
| Clause 4.4, Table-2, iii) b)(Input frequency range) |
- |
- |
|
- |
| Clause 4.1, Table-1, ii) j)(Logical Channel Number for Satellite services) |
- |
- |
|
- |
| Clause 4.1, Table-1, ii) k)(RF input signal) |
- |
- |
|
- |
| Clause 4.1, Table-1, ii) m)(LNB supply current) |
- |
- |
|
- |
| Clause 4.1, Table-1, ii) n)(LNB supply voltage) |
- |
- |
|
- |
| Clause 4.1, Table-1, ii) p)(LNB Control) |
- |
- |
|
- |
| Clause 4.1, Table-1, ii) q)(Modulation/Demodulation parameters for DVB-S & DVB-S2 standard) |
- |
- |
|
- |
| Clause 4.4, Table-2, iii) a)(Input level per carrier) |
- |
- |
|
- |
| Clause 4.4, Table-2, iv) c)(RF input impedance) |
- |
- |
|
- |
| Clause 4.4, Table-2, iv) b)(Input frequency range) |
- |
- |
|
- |
| Clause 4.4, Table-2, iv) a)(Input level per carrier) |
- |
- |
|
- |
| Clause 4.4, Table-2, v)(Symbol rate) |
- |
- |
|
- |
| Clause 4.4, Table-2, vi)(RF input return loss) |
- |
- |
|
- |
| Clause 4.4, Table-2, vii)(DisEqC) |
- |
- |
|
- |
| Clause 4.4, Table-2, viii)(Operating ambient temperature range) |
- |
- |
|
- |
| Clause 4.4, Table-2, ix)(Operating humidity range) |
- |
- |
|
- |
| Clause 4.1, Table-1, iii) a)(Interfaces, Connectors) |
- |
- |
|
- |
| Clause 4.1, Table-1, iv)(Automatic software upgrade mechanism) |
- |
- |
|
- |
| Clause 4.1, Table-1, v) a)(Remote Control) |
- |
- |
|
- |
| Clause 4.1, Table-1, v) b)(Easy to use and simple documentation) |
- |
- |
|
- |
| Clause 3.1, Table-1, v) c)(Support package) |
- |
- |
|
- |
|
27 Apr, 2029 |
- - |
| 1262 |
Intertek India Private Limited, New Delhi (E-26)
| 8136626
| IS/IEC 62368 : Part 1 (2023) |
Audio Video Information and Communication Technology Equipment - Part 1: Safety Requirements (Second Revision) |
- |
150000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl-4.1(General- materials, components) |
- |
400 |
|
10% discount offered to samples received from BIS. |
| Cl-4.2(Energy source classifications) |
- |
400 |
|
10% discount offered to samples received from BIS. |
| Cl-4.3(Protection against energy sources) |
- |
400 |
|
10% discount offered to samples received from BIS. |
| Cl-4.4(Safeguards) |
- |
400 |
|
10% discount offered to samples received from BIS. |
| Cl-4.5(Explosion) |
- |
400 |
|
10% discount offered to samples received from BIS. |
| Cl-4.6(Fixing of conductors and conductive parts) |
- |
400 |
|
10% discount offered to samples received from BIS. |
| Cl-4.7(Equipment for direct insertion into mains socket-outlets) |
- |
1000 |
|
10% discount offered to samples received from BIS. |
| Cl-4.8(Equipment containing coin or button cell batteries) |
- |
1000 |
|
10% discount offered to samples received from BIS. |
| Cl-4.9(Likelihood of fire or shock due to entry of conductive objects) |
- |
1000 |
|
10% discount offered to samples received from BIS. |
| Cl-4.10(Components requirements) |
- |
1000 |
|
10% discount offered to samples received from BIS. |
| Cl-5.1(General- Electrically-caused injury) |
- |
1000 |
|
10% discount offered to samples received from BIS. |
| Cl-5.2(Classification and limits of electrical energy sources) |
- |
2000 |
|
10% discount offered to samples received from BIS. |
| Cl-5.3(Protection against electrical energy sources) |
- |
2000 |
|
10% discount offered to samples received from BIS. |
| Cl-5.4(Insulation materials and requirements) |
- |
10000 |
|
10% discount offered to samples received from BIS. |
| Cl-5.5(Components as safeguards) |
- |
750 |
|
10% discount offered to samples received from BIS. |
| Cl-5.6(Protective conductor) |
- |
750 |
|
10% discount offered to samples received from BIS. |
| Cl-5.7(Prospective touch voltage, touch current and protective conductor current) |
- |
2000 |
|
10% discount offered to samples received from BIS. |
| Cl-5.8(Backfeed safeguard in battery backed up supplies) |
- |
2000 |
|
10% discount offered to samples received from BIS. |
| Cl-6.1(General- Electrically-caused fire) |
- |
1000 |
|
10% discount offered to samples received from BIS. |
| Cl-6.2(Classification of power sources and potential ignition sources) |
- |
2000 |
|
10% discount offered to samples received from BIS. |
| Cl-6.3(Safeguards against fire under normal operating conditions and abnormal operating conditions) |
- |
1000 |
|
10% discount offered to samples received from BIS. |
| Cl-6.4(Safeguards against fire under single fault conditions) |
- |
2000 |
|
10% discount offered to samples received from BIS. |
| Cl-6.5(Internal and external wiring) |
- |
1000 |
|
10% discount offered to samples received from BIS. |
| Cl-7.1(General- Injury caused by hazardous substances) |
- |
0 |
|
Applied in Exclusion |
| Cl-7.2(Reduction of exposure to hazardous substances) |
- |
0 |
|
Applied in Exclusion |
| Cl-7.3(Ozone exposure) |
- |
0 |
|
Applied in Exclusion |
| Cl-7.4(Use of personal safeguards or personal protective equipment (PPE) |
- |
0 |
|
Applied in Exclusion |
| Cl-7.5(Use of instructional safeguards and instructions) |
- |
0 |
|
Applied in Exclusion |
| Cl-8.1(General- Mechanically-caused injury) |
- |
1000 |
|
10% discount offered to samples received from BIS. |
| Cl-8.2(Mechanical energy source classifications) |
- |
1000 |
|
10% discount offered to samples received from BIS. |
| Cl-8.3(Safeguards against mechanical energy sources) |
- |
1000 |
|
10% discount offered to samples received from BIS. |
| Cl-8.4(Safeguards against parts with sharp edges and corners) |
- |
1000 |
|
10% discount offered to samples received from BIS. |
| Cl-8.5(Safeguards against moving parts) |
- |
1000 |
|
10% discount offered to samples received from BIS. |
| Cl-8.6(Stability of equipment) |
- |
2000 |
|
10% discount offered to samples received from BIS. |
| Cl-8.7(Equipment mounted to a wall, ceiling or other structure) |
- |
5000 |
|
10% discount offered to samples received from BIS. |
| Cl-8.8(Handle strength) |
- |
1200 |
|
10% discount offered to samples received from BIS. |
| Cl-8.9(Wheels or casters attachment requirements) |
- |
1200 |
|
10% discount offered to samples received from BIS. |
| Cl-8.10(Carts, stands, and similar carriers) |
- |
1200 |
|
10% discount offered to samples received from BIS. |
| Cl-8.11(Mounting means for slide-rail mounted equipment (SRME)) |
- |
5000 |
|
10% discount offered to samples received from BIS. |
| Cl-9.1(General-Thermal burn injury) |
- |
750 |
|
10% discount offered to samples received from BIS. |
| Cl-9.2(Thermal energy source classifications) |
- |
750 |
|
10% discount offered to samples received from BIS. |
| Cl-9.3(Touch temperature limits) |
- |
5000 |
|
10% discount offered to samples received from BIS. |
| Cl-9.4(Safeguards against thermal energy sources) |
- |
750 |
|
10% discount offered to samples received from BIS. |
| Cl-9.5(Requirements for safeguards) |
- |
750 |
|
10% discount offered to samples received from BIS. |
| Cl-9.6(Requirements for wireless power transmitters) |
- |
5000 |
|
10% discount offered to samples received from BIS. |
| Annex B(General- Normal operating condition tests, abnormal operating condition tests and single fault condition tests) |
- |
750 |
|
10% discount offered to samples received from BIS. |
| Annex B-2(Normal operating conditions) |
- |
1200 |
|
10% discount offered to samples received from BIS. |
| Annex B-3(Simulated abnormal operating conditions) |
- |
1200 |
|
10% discount offered to samples received from BIS. |
| Annex B-4(Simulated single fault conditions) |
- |
1200 |
|
10% discount offered to samples received from BIS. |
| Annex D-1(Impulse test generators) |
- |
5000 |
|
10% discount offered to samples received from BIS. |
| Annex D-2(Antenna interface test generator) |
- |
5000 |
|
10% discount offered to samples received from BIS. |
| Annex E-1(Electrical energy source classification for audio signals) |
- |
750 |
|
10% discount offered to samples received from BIS. |
| Annex E-2(Audio signals used during test) |
- |
750 |
|
10% discount offered to samples received from BIS. |
| Annex E-3(Operating conditions of equipment containing an audio amplifier) |
- |
5000 |
|
10% discount offered to samples received from BIS. |
| Annex F-1(General-Equipment markings, instructions, and instructional safeguards) |
- |
750 |
|
10% discount offered to samples received from BIS. |
| Annex F-2(Letter symbols and graphical symbols) |
- |
750 |
|
10% discount offered to samples received from BIS. |
| Annex F-3(Equipment markings) |
- |
750 |
|
10% discount offered to samples received from BIS. |
| Annex F-4(Instructions) |
- |
750 |
|
10% discount offered to samples received from BIS. |
| Annex F-5(Instructional safeguards) |
- |
750 |
|
10% discount offered to samples received from BIS. |
| Annex H-1(General- Criteria for telephone ringing signals) |
- |
750 |
|
10% discount offered to samples received from BIS. |
| Annex H-2(Method A) |
- |
1200 |
|
10% discount offered to samples received from BIS. |
| Annex H-3(Method B) |
- |
1200 |
|
10% discount offered to samples received from BIS. |
| Annex I(Overvoltage categories (see IEC 60364-4-44)) |
- |
0 |
|
Applied in Exclusion |
| Annex K-1(General- Safety interlocks) |
- |
0 |
|
Applied in Exclusion |
| Annex K-2(Components of the safety interlock safeguard mechanism) |
- |
0 |
|
Applied in Exclusion |
| Annex K-3(Inadvertent change of operating mode) |
- |
0 |
|
Applied in Exclusion |
| Annex K-4(Interlock safeguard override) |
- |
0 |
|
Applied in Exclusion |
| Annex K-5(Fail-safe) |
- |
0 |
|
Applied in Exclusion |
| Annex K-6(Mechanically operated safety interlocks) |
- |
0 |
|
Applied in Exclusion |
| Annex K-7(Interlock circuit isolation) |
- |
0 |
|
Applied in Exclusion |
| Annex L-1(General requirements) |
- |
300 |
|
10% discount offered to samples received from BIS. |
| Annex L-2(Permanently connected equipment) |
- |
300 |
|
10% discount offered to samples received from BIS. |
| Annex L-3() |
- |
300 |
|
10% discount offered to samples received from BIS. |
| Annex L-4(Single-phase equipment) |
- |
300 |
|
10% discount offered to samples received from BIS. |
| Annex L-5(Three-phase equipment) |
- |
300 |
|
10% discount offered to samples received from BIS. |
| Annex L-6(Switches as disconnect devices) |
- |
300 |
|
10% discount offered to samples received from BIS. |
| Annex L-7(Plugs as disconnect devices) |
- |
300 |
|
10% discount offered to samples received from BIS. |
| Annex L-8(Multiple power sources) |
- |
300 |
|
10% discount offered to samples received from BIS. |
| Annex L-9(Compliance criteria) |
- |
300 |
|
10% discount offered to samples received from BIS. |
| Annex M-1(General requirements) |
- |
300 |
|
10% discount offered to samples received from BIS. |
| Annex M-2(Safety of batteries and their cells) |
- |
5000 |
|
10% discount offered to samples received from BIS. |
| Annex M-3(Protection circuits for batteries provided within the equipment) |
- |
1200 |
|
10% discount offered to samples received from BIS. |
| Annex M-4(Additional safeguards for equipment containing a secondary lithium battery) |
- |
1200 |
|
10% discount offered to samples received from BIS. |
| Annex M-5(Risk of burn due to short-circuit during carrying) |
- |
1200 |
|
10% discount offered to samples received from BIS. |
| Annex M-6(Safeguards against short-circuits) |
- |
750 |
|
10% discount offered to samples received from BIS. |
| Annex M-7(Risk of explosion from lead acid and NiCd batteries) |
- |
1200 |
|
10% discount offered to samples received from BIS. |
| Annex M-8("Protection against internal ignition from external spark sources of
rechargeable batteries with aqueous electrolyte") |
- |
1200 |
|
10% discount offered to samples received from BIS. |
| Annex M-9(Preventing electrolyte spillage) |
- |
750 |
|
10% discount offered to samples received from BIS. |
| Annex N(Electrochemical potentials (V)) |
- |
0 |
|
Applied in Exclusion |
| Annex O(Measurement of creepage distances and clearances) |
- |
750 |
|
10% discount offered to samples received from BIS. |
| Annex P-1(General-Safeguards against conductive objects) |
- |
750 |
|
10% discount offered to samples received from BIS. |
| Annex P-2(Safeguards against entry or consequences of entry of a foreign object) |
- |
750 |
|
10% discount offered to samples received from BIS. |
| Annex P-3(Safeguards against spillage of internal liquids) |
- |
750 |
|
10% discount offered to samples received from BIS. |
| Annex P-4(Metallized coatings and adhesives securing parts) |
- |
0 |
|
Applied in Exclusion |
| Annex Q-1(Limited power source) |
- |
750 |
|
10% discount offered to samples received from BIS. |
| Annex Q-2(Test for external circuits – paired conductor cable) |
- |
750 |
|
10% discount offered to samples received from BIS. |
| Annex R(Limited short-circuit test) |
- |
0 |
|
Applied in Exclusion |
| Annex S-1(Flammability test for fire enclosure and fire barrier materials of equipment where the steady state power does not exceed 4 000 W) |
- |
1200 |
|
10% discount offered to samples received from BIS. |
| Annex S-2(Flammability test for fire enclosure and fire barrier integrity) |
- |
750 |
|
10% discount offered to samples received from BIS. |
| Annex S-4(Flammability classification of materials) |
- |
0 |
|
Applied in Exclusion |
| Annex S-5(Flammability test for fire enclosure materials of equipment with a steady state power exceeding 4 000 W) |
- |
2000 |
|
10% discount offered to samples received from BIS. |
| Annex T-1(General-Mechanical strength tests) |
- |
1000 |
|
10% discount offered to samples received from BIS. |
| Annex T-2(Steady force test, 10 N) |
- |
1000 |
|
10% discount offered to samples received from BIS. |
| Annex T-3(Steady force test, 30 N) |
- |
750 |
|
10% discount offered to samples received from BIS. |
| Annex T-5(Steady force test, 250 N) |
- |
2000 |
|
10% discount offered to samples received from BIS. |
| Annex T-6(Enclosure impact test) |
- |
1000 |
|
10% discount offered to samples received from BIS. |
| Annex T-7(Drop test) |
- |
1000 |
|
10% discount offered to samples received from BIS. |
| Annex T-8(Stress relief test) |
- |
3000 |
|
10% discount offered to samples received from BIS. |
| Annex T-9(Glass impact test) |
- |
1000 |
|
10% discount offered to samples received from BIS. |
| Annex T-10(Glass fragmentation test) |
- |
0 |
|
Applied in Exclusion |
| Annex T-11(Test for telescoping or rod antennas) |
- |
2000 |
|
10% discount offered to samples received from BIS. |
| Annex V-1(Accessible parts of equipment) |
- |
2000 |
|
10% discount offered to samples received from BIS. |
| Annex V-2(Accessible part criterion) |
- |
2000 |
|
10% discount offered to samples received from BIS. |
| Annex W(Comparison of terms introduced in this document) |
- |
300 |
|
10% discount offered to samples received from BIS. |
| Annex X("Alternative method for determining clearances for insulation in
circuits connected to an AC mains not exceeding 420 V peak (300 V RMS)") |
- |
700 |
|
10% discount offered to samples received from BIS. |
| Annex Y-1(General- Construction requirements for outdoor enclosures) |
- |
5000 |
|
10% discount offered to samples received from BIS. |
| Annex Y-4(Gaskets) |
- |
0 |
|
Applied in Exclusion |
| Annex Y-5(Protection of equipment within an outdoor enclosure) |
- |
5000 |
|
10% discount offered to samples received from BIS. |
| Annex T-4(Steady force test, 100 N) |
- |
750 |
|
10% discount offered to samples received from BIS. |
| Annex S-3(Flammability tests for the bottom of a fire enclosure) |
- |
2000 |
|
10% discount offered to samples received from BIS. |
| Cl-4.1(General- materials, components) |
- |
0 |
|
Repeated |
| Cl-4.2(Energy source classifications) |
- |
0 |
|
Repeated |
| Cl-4.3(Protection against energy sources) |
- |
0 |
|
Repeated |
| Cl-4.4(Safeguards) |
- |
0 |
|
Repeated |
| Cl-4.5(Explosion) |
- |
0 |
|
Repeated |
| Cl-4.6(Fixing of conductors and conductive parts) |
- |
0 |
|
Repeated |
| Cl-4.7(Equipment for direct insertion into mains socket-outlets) |
- |
0 |
|
Repeated |
| Cl-4.8(Equipment containing coin or button cell batteries) |
- |
0 |
|
Repeated |
| Cl-4.9(Likelihood of fire or shock due to entry of conductive objects) |
- |
0 |
|
Repeated |
| Cl-4.10(Components requirements) |
- |
0 |
|
- |
| Cl-5.1(General- Electrically-caused injury) |
- |
0 |
|
- |
| Cl-5.2(Classification and limits of electrical energy sources) |
- |
0 |
|
- |
| Cl-5.3(Protection against electrical energy sources) |
- |
0 |
|
- |
| Cl-5.4(Insulation materials and requirements) |
- |
0 |
|
- |
| Cl-5.5(Components as safeguards) |
- |
0 |
|
- |
| Cl-5.6(Protective conductor) |
- |
0 |
|
- |
| Cl-5.7(Prospective touch voltage, touch current and protective conductor current) |
- |
0 |
|
- |
| Cl-5.8(Backfeed safeguard in battery backed up supplies) |
- |
0 |
|
- |
| Cl-6.1(General- Electrically-caused fire) |
- |
0 |
|
- |
| Cl-6.2(Classification of power sources and potential ignition sources) |
- |
0 |
|
- |
| Cl-6.3(Safeguards against fire under normal operating conditions and abnormal operating conditions) |
- |
0 |
|
- |
| Cl-6.4(Safeguards against fire under single fault conditions) |
- |
0 |
|
- |
| Cl-6.5(Internal and external wiring) |
- |
0 |
|
- |
| Cl-8.1(General- Mechanically-caused injury) |
- |
0 |
|
- |
| Cl-8.2(Mechanical energy source classifications) |
- |
0 |
|
- |
| Cl-8.3(Safeguards against mechanical energy sources) |
- |
0 |
|
- |
| Cl-8.4(Safeguards against parts with sharp edges and corners) |
- |
0 |
|
- |
| Cl-8.5(Safeguards against moving parts) |
- |
0 |
|
- |
| Cl-8.6(Stability of equipment) |
- |
0 |
|
- |
| Cl-8.7(Equipment mounted to a wall, ceiling or other structure) |
- |
0 |
|
- |
| Cl-8.8(Handle strength) |
- |
0 |
|
- |
| Cl-8.9(Wheels or casters attachment requirements) |
- |
0 |
|
- |
| Cl-8.10(Carts, stands, and similar carriers) |
- |
0 |
|
- |
| Cl-8.11(Mounting means for slide-rail mounted equipment (SRME)) |
- |
0 |
|
- |
| Cl-9.1(General-Thermal burn injury) |
- |
0 |
|
- |
| Cl-9.2(Thermal energy source classifications) |
- |
0 |
|
- |
| Cl-9.3(Touch temperature limits) |
- |
0 |
|
- |
| Cl-9.4(Safeguards against thermal energy sources) |
- |
0 |
|
- |
| Cl-9.5(Requirements for safeguards) |
- |
0 |
|
- |
| Cl-9.6(Requirements for wireless power transmitters) |
- |
0 |
|
- |
| Annex B(General- Normal operating condition tests, abnormal operating condition tests and single fault condition tests) |
- |
0 |
|
- |
| Annex B-2(Normal operating conditions) |
- |
0 |
|
- |
| Annex B-3(Simulated abnormal operating conditions) |
- |
0 |
|
- |
| Annex B-4(Simulated single fault conditions) |
- |
0 |
|
- |
| Annex D-1(Impulse test generators) |
- |
0 |
|
- |
| Annex D-2(Antenna interface test generator) |
- |
0 |
|
- |
| Annex E-1(Electrical energy source classification for audio signals) |
- |
0 |
|
- |
| Annex E-2(Audio signals used during test) |
- |
0 |
|
- |
| Annex E-3(Operating conditions of equipment containing an audio amplifier) |
- |
0 |
|
- |
| Annex F-1(General-Equipment markings, instructions, and instructional safeguards) |
- |
0 |
|
- |
| Annex F-2(Letter symbols and graphical symbols) |
- |
0 |
|
- |
| Annex F-3(Equipment markings) |
- |
0 |
|
- |
| Annex F-4(Instructions) |
- |
0 |
|
- |
| Annex F-5(Instructional safeguards) |
- |
0 |
|
- |
| Annex H-1(General- Criteria for telephone ringing signals) |
- |
0 |
|
- |
| Annex H-2(Method A) |
- |
0 |
|
- |
| Annex H-3(Method B) |
- |
0 |
|
- |
| Annex I(Overvoltage categories (see IEC 60364-4-44)) |
- |
0 |
|
- |
| Annex K-1(General- Safety interlocks) |
- |
0 |
|
- |
| Annex K-3(Inadvertent change of operating mode) |
- |
0 |
|
- |
| Annex K-4(Interlock safeguard override) |
- |
0 |
|
- |
| Annex K-5(Fail-safe) |
- |
0 |
|
- |
| Annex L-1(General requirements) |
- |
0 |
|
- |
| Annex L-2(Permanently connected equipment) |
- |
0 |
|
- |
| Annex L-3() |
- |
0 |
|
- |
| Annex L-4(Single-phase equipment) |
- |
0 |
|
- |
| Annex L-5(Three-phase equipment) |
- |
0 |
|
- |
| Annex L-6(Switches as disconnect devices) |
- |
0 |
|
- |
| Annex L-7(Plugs as disconnect devices) |
- |
0 |
|
- |
| Annex L-8(Multiple power sources) |
- |
0 |
|
- |
| Annex L-9(Compliance criteria) |
- |
0 |
|
- |
| Annex M-1(General requirements) |
- |
0 |
|
- |
| Annex M-2(Safety of batteries and their cells) |
- |
0 |
|
- |
| Annex M-3(Protection circuits for batteries provided within the equipment) |
- |
0 |
|
- |
| Annex M-4(Additional safeguards for equipment containing a secondary lithium battery) |
- |
0 |
|
- |
| Annex M-5(Risk of burn due to short-circuit during carrying) |
- |
0 |
|
- |
| Annex M-6(Safeguards against short-circuits) |
- |
0 |
|
- |
| Annex M-7(Risk of explosion from lead acid and NiCd batteries) |
- |
0 |
|
- |
| Annex M-8("Protection against internal ignition from external spark sources of
rechargeable batteries with aqueous electrolyte") |
- |
0 |
|
- |
| Annex M-9(Preventing electrolyte spillage) |
- |
0 |
|
- |
| Annex O(Measurement of creepage distances and clearances) |
- |
0 |
|
- |
| Annex P-1(General-Safeguards against conductive objects) |
- |
0 |
|
- |
| Annex P-2(Safeguards against entry or consequences of entry of a foreign object) |
- |
0 |
|
- |
| Annex P-3(Safeguards against spillage of internal liquids) |
- |
0 |
|
- |
| Annex Q-1(Limited power source) |
- |
0 |
|
- |
| Annex Q-2(Test for external circuits – paired conductor cable) |
- |
0 |
|
- |
| Annex S-1(Flammability test for fire enclosure and fire barrier materials of equipment where the steady state power does not exceed 4 000 W) |
- |
0 |
|
- |
| Annex S-2(Flammability test for fire enclosure and fire barrier integrity) |
- |
0 |
|
- |
| Annex S-3(Flammability tests for the bottom of a fire enclosure) |
- |
0 |
|
- |
| Annex S-5(Flammability test for fire enclosure materials of equipment with a steady state power exceeding 4 000 W) |
- |
0 |
|
- |
| Annex T-1(General-Mechanical strength tests) |
- |
0 |
|
- |
| Annex T-2(Steady force test, 10 N) |
- |
0 |
|
- |
| Annex T-3(Steady force test, 30 N) |
- |
0 |
|
- |
| Annex T-5(Steady force test, 250 N) |
- |
0 |
|
- |
| Annex T-6(Enclosure impact test) |
- |
0 |
|
- |
| Annex T-7(Drop test) |
- |
0 |
|
- |
| Annex T-8(Stress relief test) |
- |
0 |
|
- |
| Annex T-9(Glass impact test) |
- |
0 |
|
- |
| Annex T-11(Test for telescoping or rod antennas) |
- |
0 |
|
- |
| Annex V-1(Accessible parts of equipment) |
- |
0 |
|
- |
| Annex V-2(Accessible part criterion) |
- |
0 |
|
- |
| Annex W(Comparison of terms introduced in this document) |
- |
0 |
|
- |
| Annex X("Alternative method for determining clearances for insulation in
circuits connected to an AC mains not exceeding 420 V peak (300 V RMS)") |
- |
0 |
|
- |
| Annex Y-1(General- Construction requirements for outdoor enclosures) |
- |
0 |
|
- |
| Annex Y-5(Protection of equipment within an outdoor enclosure) |
- |
0 |
|
- |
| Annex T-4(Steady force test, 100 N) |
- |
0 |
|
- |
| Cl-4.1(General- materials, components) |
- |
0 |
|
- |
| Cl-4.2(Energy source classifications) |
- |
0 |
|
- |
| Cl-4.3(Protection against energy sources) |
- |
0 |
|
- |
| Cl-4.4(Safeguards) |
- |
0 |
|
- |
| Cl-4.5(Explosion) |
- |
0 |
|
- |
| Cl-4.6(Fixing of conductors and conductive parts) |
- |
0 |
|
- |
| Cl-4.7(Equipment for direct insertion into mains socket-outlets) |
- |
0 |
|
- |
| Cl-4.8(Equipment containing coin or button cell batteries) |
- |
0 |
|
- |
| Cl-4.9(Likelihood of fire or shock due to entry of conductive objects) |
- |
0 |
|
- |
| Cl-4.1(General- materials, components) |
- |
- |
|
- |
| Cl-4.2(Energy source classifications) |
- |
- |
|
- |
| Cl-4.3(Protection against energy sources) |
- |
- |
|
- |
| Cl-4.4(Safeguards) |
- |
- |
|
- |
| Cl-4.5(Explosion) |
- |
- |
|
- |
| Cl-4.6(Fixing of conductors and conductive parts) |
- |
- |
|
- |
| Cl-4.7(Equipment for direct insertion into mains socket-outlets) |
- |
- |
|
- |
| Cl-4.8(Equipment containing coin or button cell batteries) |
- |
- |
|
- |
| Cl-4.9(Likelihood of fire or shock due to entry of conductive objects) |
- |
- |
|
- |
| Cl-4.10(Components requirements) |
- |
- |
|
- |
| Cl-5.1(General- Electrically-caused injury) |
- |
- |
|
- |
| Cl-5.2(Classification and limits of electrical energy sources) |
- |
- |
|
- |
| Cl-5.3(Protection against electrical energy sources) |
- |
- |
|
- |
| Cl-5.4(Insulation materials and requirements) |
- |
- |
|
- |
| Cl-5.5(Components as safeguards) |
- |
- |
|
- |
| Cl-5.6(Protective conductor) |
- |
- |
|
- |
| Cl-5.7(Prospective touch voltage, touch current and protective conductor current) |
- |
- |
|
- |
| Cl-5.8(Backfeed safeguard in battery backed up supplies) |
- |
- |
|
- |
| Cl-6.1(General- Electrically-caused fire) |
- |
- |
|
- |
| Cl-6.2(Classification of power sources and potential ignition sources) |
- |
- |
|
- |
| Cl-6.3(Safeguards against fire under normal operating conditions and abnormal operating conditions) |
- |
- |
|
- |
| Cl-6.4(Safeguards against fire under single fault conditions) |
- |
- |
|
- |
| Cl-6.5(Internal and external wiring) |
- |
- |
|
- |
| Cl-8.1(General- Mechanically-caused injury) |
- |
- |
|
- |
| Cl-8.2(Mechanical energy source classifications) |
- |
- |
|
- |
| Cl-8.3(Safeguards against mechanical energy sources) |
- |
- |
|
- |
| Cl-8.4(Safeguards against parts with sharp edges and corners) |
- |
- |
|
- |
| Cl-8.5(Safeguards against moving parts) |
- |
- |
|
- |
| Cl-8.6(Stability of equipment) |
- |
- |
|
- |
| Cl-8.7(Equipment mounted to a wall, ceiling or other structure) |
- |
- |
|
- |
| Cl-8.8(Handle strength) |
- |
- |
|
- |
| Cl-8.9(Wheels or casters attachment requirements) |
- |
- |
|
- |
| Cl-8.10(Carts, stands, and similar carriers) |
- |
- |
|
- |
| Cl-8.11(Mounting means for slide-rail mounted equipment (SRME)) |
- |
- |
|
- |
| Cl-9.1(General-Thermal burn injury) |
- |
- |
|
- |
| Cl-9.2(Thermal energy source classifications) |
- |
- |
|
- |
| Cl-9.3(Touch temperature limits) |
- |
- |
|
- |
| Cl-9.4(Safeguards against thermal energy sources) |
- |
- |
|
- |
| Cl-9.5(Requirements for safeguards) |
- |
- |
|
- |
| Cl-9.6(Requirements for wireless power transmitters) |
- |
- |
|
- |
| Annex B(General- Normal operating condition tests, abnormal operating condition tests and single fault condition tests) |
- |
- |
|
- |
| Annex B-2(Normal operating conditions) |
- |
- |
|
- |
| Annex B-3(Simulated abnormal operating conditions) |
- |
- |
|
- |
| Annex B-4(Simulated single fault conditions) |
- |
- |
|
- |
| Annex D-1(Impulse test generators) |
- |
- |
|
- |
| Annex D-2(Antenna interface test generator) |
- |
- |
|
- |
| Annex E-1(Electrical energy source classification for audio signals) |
- |
- |
|
- |
| Annex E-2(Audio signals used during test) |
- |
- |
|
- |
| Annex E-3(Operating conditions of equipment containing an audio amplifier) |
- |
- |
|
- |
| Annex F-1(General-Equipment markings, instructions, and instructional safeguards) |
- |
- |
|
- |
| Annex F-2(Letter symbols and graphical symbols) |
- |
- |
|
- |
| Annex F-3(Equipment markings) |
- |
- |
|
- |
| Annex F-4(Instructions) |
- |
- |
|
- |
| Annex F-5(Instructional safeguards) |
- |
- |
|
- |
| Annex H-1(General- Criteria for telephone ringing signals) |
- |
- |
|
- |
| Annex H-2(Method A) |
- |
- |
|
- |
| Annex H-3(Method B) |
- |
- |
|
- |
| Annex L-1(General requirements) |
- |
- |
|
- |
| Annex L-2(Permanently connected equipment) |
- |
- |
|
- |
| Annex L-3() |
- |
- |
|
- |
| Annex L-4(Single-phase equipment) |
- |
- |
|
- |
| Annex L-5(Three-phase equipment) |
- |
- |
|
- |
| Annex L-6(Switches as disconnect devices) |
- |
- |
|
- |
| Annex L-7(Plugs as disconnect devices) |
- |
- |
|
- |
| Annex L-8(Multiple power sources) |
- |
- |
|
- |
| Annex L-9(Compliance criteria) |
- |
- |
|
- |
| Annex M-1(General requirements) |
- |
- |
|
- |
| Annex M-2(Safety of batteries and their cells) |
- |
- |
|
- |
| Annex M-3(Protection circuits for batteries provided within the equipment) |
- |
- |
|
- |
| Annex M-4(Additional safeguards for equipment containing a secondary lithium battery) |
- |
- |
|
- |
| Annex M-5(Risk of burn due to short-circuit during carrying) |
- |
- |
|
- |
| Annex M-6(Safeguards against short-circuits) |
- |
- |
|
- |
| Annex M-7(Risk of explosion from lead acid and NiCd batteries) |
- |
- |
|
- |
| Annex M-8("Protection against internal ignition from external spark sources of
rechargeable batteries with aqueous electrolyte") |
- |
- |
|
- |
| Annex M-9(Preventing electrolyte spillage) |
- |
- |
|
- |
| Annex O(Measurement of creepage distances and clearances) |
- |
- |
|
- |
| Annex P-1(General-Safeguards against conductive objects) |
- |
- |
|
- |
| Annex P-2(Safeguards against entry or consequences of entry of a foreign object) |
- |
- |
|
- |
| Annex P-3(Safeguards against spillage of internal liquids) |
- |
- |
|
- |
| Annex Q-1(Limited power source) |
- |
- |
|
- |
| Annex Q-2(Test for external circuits – paired conductor cable) |
- |
- |
|
- |
| Annex S-1(Flammability test for fire enclosure and fire barrier materials of equipment where the steady state power does not exceed 4 000 W) |
- |
- |
|
- |
| Annex S-2(Flammability test for fire enclosure and fire barrier integrity) |
- |
- |
|
- |
| Annex S-3(Flammability tests for the bottom of a fire enclosure) |
- |
- |
|
- |
| Annex S-5(Flammability test for fire enclosure materials of equipment with a steady state power exceeding 4 000 W) |
- |
- |
|
- |
| Annex T-1(General-Mechanical strength tests) |
- |
- |
|
- |
| Annex T-2(Steady force test, 10 N) |
- |
- |
|
- |
| Annex T-3(Steady force test, 30 N) |
- |
- |
|
- |
| Annex T-5(Steady force test, 250 N) |
- |
- |
|
- |
| Annex T-6(Enclosure impact test) |
- |
- |
|
- |
| Annex T-7(Drop test) |
- |
- |
|
- |
| Annex T-8(Stress relief test) |
- |
- |
|
- |
| Annex T-9(Glass impact test) |
- |
- |
|
- |
| Annex T-11(Test for telescoping or rod antennas) |
- |
- |
|
- |
| Annex V-1(Accessible parts of equipment) |
- |
- |
|
- |
| Annex V-2(Accessible part criterion) |
- |
- |
|
- |
| Annex W(Comparison of terms introduced in this document) |
- |
- |
|
- |
| Annex X("Alternative method for determining clearances for insulation in
circuits connected to an AC mains not exceeding 420 V peak (300 V RMS)") |
- |
- |
|
- |
| Annex Y-1(General- Construction requirements for outdoor enclosures) |
- |
- |
|
- |
| Annex Y-5(Protection of equipment within an outdoor enclosure) |
- |
- |
|
- |
| Annex T-4(Steady force test, 100 N) |
- |
- |
|
- |
|
27 Apr, 2029 |
- - |
| 1263 |
Intertek India Private Limited, New Delhi (E-26)
| 8136626
| IS 302 : Part 2 : Sec 6 (2009) |
Safety of household and similar electrical appliances: Part 2 particular requirements: Sec 6 cooking ranges, hobs, ovens and similar appliances (First Revision) |
- |
50000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 6.0(Classification) |
- |
1000 |
|
15% discount offered to samples received from BIS. |
| 7.0(Marking and instructions) |
- |
1000 |
|
15% discount offered to samples received from BIS. |
| 8.0(Protection against access to live part test) |
- |
2000 |
|
15% discount offered to samples received from BIS. |
| 9.0(Starting of motor-operated appliances test) |
- |
0 |
|
This Clause is not Applicable. |
| 10.0(Power Input and current test) |
- |
1000 |
|
15% discount offered to samples received from BIS. |
| 11.0(Heating test) |
- |
3000 |
|
15% discount offered to samples received from BIS. |
| 13.0(Leakage current and electric strength test) |
- |
4000 |
|
15% discount offered to samples received from BIS. |
| 14.0(Transient voltages) |
- |
4000 |
|
15% discount offered to samples received from BIS. |
| 15.0(Moisture Resistance) |
- |
3000 |
|
15% discount offered to samples received from BIS. |
| 16.0(Leakage current and electric strength test) |
- |
5000 |
|
15% discount offered to samples received from BIS. |
| 17.0(Overload protection of transformers test) |
- |
2000 |
|
15% discount offered to samples received from BIS. |
| 18.0(Endurance test) |
- |
0 |
|
This Clause is not Applicable. |
| 19.0(Abnormal Operations) |
- |
2000 |
|
15% discount offered to samples received from BIS. |
| 20.0(Stability and Mechanical Hazards) |
- |
3000 |
|
15% discount offered to samples received from BIS. |
| 21.0(Mechanical Strength) |
- |
2000 |
|
15% discount offered to samples received from BIS. |
| 22.0(Construction verification related tests) |
- |
2000 |
|
15% discount offered to samples received from BIS. |
| 23.0(Internal wiring) |
- |
2000 |
|
15% discount offered to samples received from BIS. |
| 24.0(Components) |
- |
2000 |
|
15% discount offered to samples received from BIS. |
| 25.0(Supply connections and External Flexible Cords) |
- |
1000 |
|
15% discount offered to samples received from BIS. |
| 26.0(Terminal for External Conductors) |
- |
1000 |
|
15% discount offered to samples received from BIS. |
| 27.0(Provision for Earthing) |
- |
1000 |
|
15% discount offered to samples received from BIS. |
| 28.0(Screws and connections) |
- |
1000 |
|
15% discount offered to samples received from BIS. |
| 29.0(Clearances and Creepage distances and solid insulation) |
- |
1000 |
|
15% discount offered to samples received from BIS. |
| 30.0(Resistance to heat and fire) |
- |
3000 |
|
15% discount offered to samples received from BIS. |
| 31.0(Resistance to rusting) |
- |
2000 |
|
15% discount offered to samples received from BIS. |
| 4(General Requirements) |
- |
500 |
|
15% discount offered to samples received from BIS. |
| 5(General condition for the tests) |
- |
500 |
|
15% discount offered to samples received from BIS. |
| 6.0(Classification) |
- |
0 |
|
Repeated clause |
| 7.0(Marking and instructions) |
- |
0 |
|
Repeated clause |
| 8.0(Protection against access to live part test) |
- |
0 |
|
Repeated clause |
| 9.0(Starting of motor-operated appliances test) |
- |
0 |
|
This clause is not applicable. |
| 10.0(Power Input and current test) |
- |
0 |
|
Repeated clause |
| 11.0(Heating test) |
- |
0 |
|
Repeated clause |
| 13.0(Leakage current and electric strength test) |
- |
0 |
|
Repeated clause |
| 14.0(Transient voltages) |
- |
0 |
|
Repeated clause |
| 15.0(Moisture Resistance) |
- |
0 |
|
Repeated clause |
| 16.0(Leakage current and electric strength test) |
- |
0 |
|
Repeated clause |
| 17.0(Overload protection of transformers test) |
- |
0 |
|
Repeated clause |
| 18.0(Endurance test) |
- |
0 |
|
This clause is not applicable. |
| 19.0(Abnormal Operations) |
- |
0 |
|
Repeated clause |
| 20.0(Stability and Mechanical Hazards) |
- |
0 |
|
Repeated clause |
| 21.0(Mechanical Strength) |
- |
0 |
|
Repeated clause |
| 22.0(Construction verification related tests) |
- |
0 |
|
Repeated clause |
| 23.0(Internal wiring) |
- |
0 |
|
Repeated clause |
| 24.0(Components) |
- |
0 |
|
Repeated clause |
| 25.0(Supply connections and External Flexible Cords) |
- |
0 |
|
Repeated clause |
| 26.0(Terminal for External Conductors) |
- |
0 |
|
Repeated clause |
| 27.0(Provision for Earthing) |
- |
0 |
|
Repeated clause |
| 28.0(Screws and connections) |
- |
0 |
|
Repeated clause |
| 29.0(Clearances and Creepage distances and solid insulation) |
- |
0 |
|
Repeated clause |
| 30.0(Resistance to heat and fire) |
- |
0 |
|
Repeated clause |
| 31.0(Resistance to rusting) |
- |
0 |
|
Repeated clause |
| 4(General Requirements) |
- |
0 |
|
Repeated clause |
| 5(General condition for the tests) |
- |
0 |
|
Repeated clause |
|
27 Apr, 2029 |
- - |
| 1264 |
Intertek India Private Limited, New Delhi (E-26)
| 8136626
| IS 302 : Part 2 : Sec 4 (1993) |
Safety of household and similar electrical appliances: Part 2 particular requirements: Sec 4 spin extractors |
- |
110000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 3(GENERAL REQUIREMENTS) |
- |
2000 |
|
15% discount offered to samples received from BIS. |
| 4(GENERAL NOTES ON TESTS) |
- |
2000 |
|
15% discount offered to samples received from BIS. |
| 5(RATING) |
- |
2000 |
|
15% discount offered to samples received from BIS. |
| 6(CLASSIFICATION) |
- |
2000 |
|
15% discount offered to samples received from BIS. |
| 7(MARKING) |
- |
5000 |
|
15% discount offered to samples received from BIS. |
| 8(PROTECTION AGAINST ELECTRIC SHOCK) |
- |
10000 |
|
15% discount offered to samples received from BIS. |
| 9(STARTING OF MOTOR-OPERATED APPLIANCES) |
- |
10000 |
|
15% discount offered to samples received from BIS. |
| 10(INPUT AND CURRENT) |
- |
5000 |
|
15% discount offered to samples received from BIS. |
| 11(HEATING) |
- |
2000 |
|
15% discount offered to samples received from BIS. |
| 13(ELECTRICAL INSULATION AND LEAKAGE CURRENT AT OPERATING TEMPERATURE) |
- |
5000 |
|
15% discount offered to samples received from BIS. |
| 14(RADIO AND TELEVISION INTERFERENCE SUPPRESSION) |
- |
10000 |
|
15% discount offered to samples received from BIS. |
| 15(MOISTURE RESISTANCE) |
- |
5000 |
|
15% discount offered to samples received from BIS. |
| 16(INSULATION RESISTANCE AND ELECTRIC STRENGTH (AFTER HUMIDITY TREATMENT)) |
- |
5000 |
|
15% discount offered to samples received from BIS. |
| 17(OVERLOAD PROTECTION) |
- |
5000 |
|
15% discount offered to samples received from BIS. |
| 19(ABNORMAL OPERATION) |
- |
5000 |
|
15% discount offered to samples received from BIS. |
| 20(STABILITY AND MECHANICAL HAZARDS) |
- |
5000 |
|
15% discount offered to samples received from BIS. |
| 21(MECHANICAL STRENGTH) |
- |
5000 |
|
15% discount offered to samples received from BIS. |
| 22(CONSTRUCTION) |
- |
3000 |
|
15% discount offered to samples received from BIS. |
| 23(INTERNAL WIRING) |
- |
2500 |
|
15% discount offered to samples received from BIS. |
| 24(COMPONENTS) |
- |
2500 |
|
15% discount offered to samples received from BIS. |
| 25(SUPPLY CONNECTION AND EXTERNAL FLEXIBLE CABLES AND CORDS) |
- |
5000 |
|
15% discount offered to samples received from BIS. |
| 26(TERMINALS FOR EXTERNAL CONDUCTORS) |
- |
2000 |
|
15% discount offered to samples received from BIS. |
| 27(PROVISION FOR EARTHING) |
- |
2000 |
|
15% discount offered to samples received from BIS. |
| 28(SCREWS AND CONNECTIONS) |
- |
2000 |
|
15% discount offered to samples received from BIS. |
| 29(CREEPAGE DISTANCES, CLEARANCES AND DISTANCES THROUGH INSULATION) |
- |
2000 |
|
15% discount offered to samples received from BIS. |
| 30(RESISTANCE TO HEAT, FIRE AND TRACKING) |
- |
2000 |
|
15% discount offered to samples received from BIS. |
| 31(RESISTANCE TO RUSTING) |
- |
2000 |
|
15% discount offered to samples received from BIS. |
| 3(GENERAL REQUIREMENTS) |
- |
2000 |
|
15% discount offered to samples received from BIS. |
| 4(GENERAL NOTES ON TESTS) |
- |
2000 |
|
15% discount offered to samples received from BIS. |
| 5(RATING) |
- |
2000 |
|
15% discount offered to samples received from BIS. |
| 6(CLASSIFICATION) |
- |
2000 |
|
15% discount offered to samples received from BIS. |
| 7(MARKING) |
- |
5000 |
|
15% discount offered to samples received from BIS. |
| 8(PROTECTION AGAINST ELECTRIC SHOCK) |
- |
5000 |
|
15% discount offered to samples received from BIS. |
| 9(STARTING OF MOTOR-OPERATED APPLIANCES) |
- |
5000 |
|
15% discount offered to samples received from BIS. |
| 10(INPUT AND CURRENT) |
- |
5000 |
|
15% discount offered to samples received from BIS. |
| 11(HEATING) |
- |
2000 |
|
15% discount offered to samples received from BIS. |
| 13(ELECTRICAL INSULATION AND LEAKAGE CURRENT AT OPERATING TEMPERATURE) |
- |
5000 |
|
15% discount offered to samples received from BIS. |
| 14(RADIO AND TELEVISION INTERFERENCE SUPPRESSION) |
- |
10000 |
|
15% discount offered to samples received from BIS. |
| 15(MOISTURE RESISTANCE) |
- |
5000 |
|
15% discount offered to samples received from BIS. |
| 16(INSULATION RESISTANCE AND ELECTRIC STRENGTH (AFTER HUMIDITY TREATMENT)) |
- |
5000 |
|
15% discount offered to samples received from BIS. |
| 17(OVERLOAD PROTECTION) |
- |
5000 |
|
15% discount offered to samples received from BIS. |
| 19(ABNORMAL OPERATION) |
- |
5000 |
|
15% discount offered to samples received from BIS. |
| 20(STABILITY AND MECHANICAL HAZARDS) |
- |
5000 |
|
15% discount offered to samples received from BIS. |
| 21(MECHANICAL STRENGTH) |
- |
5000 |
|
15% discount offered to samples received from BIS. |
| 22(CONSTRUCTION) |
- |
3000 |
|
15% discount offered to samples received from BIS. |
| 23(INTERNAL WIRING) |
- |
2500 |
|
15% discount offered to samples received from BIS. |
| 24(COMPONENTS) |
- |
2500 |
|
15% discount offered to samples received from BIS. |
| 25(SUPPLY CONNECTION AND EXTERNAL FLEXIBLE CABLES AND CORDS) |
- |
5000 |
|
15% discount offered to samples received from BIS. |
| 26(TERMINALS FOR EXTERNAL CONDUCTORS) |
- |
2000 |
|
15% discount offered to samples received from BIS. |
| 27(PROVISION FOR EARTHING) |
- |
2000 |
|
15% discount offered to samples received from BIS. |
| 28(SCREWS AND CONNECTIONS) |
- |
2000 |
|
15% discount offered to samples received from BIS. |
| 29(CREEPAGE DISTANCES, CLEARANCES AND DISTANCES THROUGH INSULATION) |
- |
2000 |
|
15% discount offered to samples received from BIS. |
| 30(RESISTANCE TO HEAT, FIRE AND TRACKING) |
- |
2000 |
|
15% discount offered to samples received from BIS. |
| 31(RESISTANCE TO RUSTING) |
- |
2000 |
|
15% discount offered to samples received from BIS. |
| 3(GENERAL REQUIREMENTS) |
- |
0 |
|
- |
| 4(GENERAL NOTES ON TESTS) |
- |
0 |
|
- |
| 5(RATING) |
- |
0 |
|
- |
| 6(CLASSIFICATION) |
- |
0 |
|
- |
| 7(MARKING) |
- |
0 |
|
- |
| 8(PROTECTION AGAINST ELECTRIC SHOCK) |
- |
0 |
|
- |
| 9(STARTING OF MOTOR-OPERATED APPLIANCES) |
- |
0 |
|
- |
| 10(INPUT AND CURRENT) |
- |
0 |
|
- |
| 11(HEATING) |
- |
0 |
|
- |
| 13(ELECTRICAL INSULATION AND LEAKAGE CURRENT AT OPERATING TEMPERATURE) |
- |
0 |
|
- |
| 14(RADIO AND TELEVISION INTERFERENCE SUPPRESSION) |
- |
0 |
|
- |
| 15(MOISTURE RESISTANCE) |
- |
0 |
|
- |
| 16(INSULATION RESISTANCE AND ELECTRIC STRENGTH (AFTER HUMIDITY TREATMENT)) |
- |
0 |
|
- |
| 17(OVERLOAD PROTECTION) |
- |
0 |
|
- |
| 19(ABNORMAL OPERATION) |
- |
0 |
|
- |
| 20(STABILITY AND MECHANICAL HAZARDS) |
- |
0 |
|
- |
| 21(MECHANICAL STRENGTH) |
- |
0 |
|
- |
| 22(CONSTRUCTION) |
- |
0 |
|
- |
| 23(INTERNAL WIRING) |
- |
0 |
|
- |
| 24(COMPONENTS) |
- |
0 |
|
- |
| 25(SUPPLY CONNECTION AND EXTERNAL FLEXIBLE CABLES AND CORDS) |
- |
0 |
|
- |
| 26(TERMINALS FOR EXTERNAL CONDUCTORS) |
- |
0 |
|
- |
| 27(PROVISION FOR EARTHING) |
- |
0 |
|
- |
| 28(SCREWS AND CONNECTIONS) |
- |
0 |
|
- |
| 29(CREEPAGE DISTANCES, CLEARANCES AND DISTANCES THROUGH INSULATION) |
- |
0 |
|
- |
| 30(RESISTANCE TO HEAT, FIRE AND TRACKING) |
- |
0 |
|
- |
| 31(RESISTANCE TO RUSTING) |
- |
0 |
|
- |
|
27 Apr, 2029 |
- - |
| 1265 |
Intertek India Private Limited, New Delhi (E-26)
| 8136626
| IS 302 : Part 1 (2024) |
Household and Similar Electrical Appliances â Safety Part 1 General Requirements (Seventh Revision) |
- |
154000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 11.8(Temperature rise) |
- |
10000 |
|
15% discount offered to samples received from BIS. |
| 11.7(Duration corresponding) |
- |
0 |
|
- |
| 11.6(Combined appliances) |
- |
0 |
|
- |
| 11.5(Motor-operated appliances) |
- |
0 |
|
- |
| 11.4(Heating appliances) |
- |
0 |
|
- |
| 8.1.5(Live parts of built-in appliances) |
- |
1000 |
|
15% discount offered to samples received from BIS. |
| 18(Endurance) |
- |
0 |
|
- |
| 17(Overload protection of transformers and associated circuits) |
- |
10000 |
|
15% discount offered to samples received from BIS. |
| 17(Over Load Protection of Transformers and associated circuits) |
- |
0 |
|
Repeated clause |
| 16(Leakage current and electric strength) |
- |
0 |
|
- |
| 4(General requirement) |
- |
0 |
|
- |
| 32.1(Radiation Toxicity and Similar Hazards) |
- |
0 |
|
- |
| 31(Resistance to Rusting) |
- |
0 |
|
- |
| 30.2(Needle Flame Test) |
- |
5000 |
|
15% discount offered to samples received from BIS. |
| 30.2(Glow Wire Test) |
- |
5000 |
|
15% discount offered to samples received from BIS. |
| 30.1(Ball pressure test) |
- |
10000 |
|
15% discount offered to samples received from BIS. |
| 29(clearance, creepage distances and solid insulation) |
- |
5000 |
|
15% discount offered to samples received from BIS. |
| 28(Screw test and connections) |
- |
5000 |
|
15% discount offered to samples received from BIS. |
| 27.1(Provision for Earthing, IS 302-1) |
- |
5000 |
|
15% discount offered to samples received from BIS. |
| 26(Terminals for external conductors) |
- |
2000 |
|
15% discount offered to samples received from BIS. |
| 25.8(Supply Connection and External Flexible Cords, IS 302-1) |
- |
2000 |
|
15% discount offered to samples received from BIS. |
| 24(Components) |
- |
0 |
|
- |
| 23.1(Internal Wiring, IS 302-1) |
- |
0 |
|
- |
| 22.1(Construction, IS 302-1) |
- |
10000 |
|
15% discount offered to samples received from BIS. |
| 21.1(Mechanical Strength, IS 302-1) |
- |
5000 |
|
15% discount offered to samples received from BIS. |
| 20.1(Stability & Mechanical Hazards, IS 302-1) |
- |
5000 |
|
15% discount offered to samples received from BIS. |
| 19(Abnormal Operation) |
- |
20000 |
|
15% discount offered to samples received from BIS. |
| 18(Endurance) |
- |
0 |
|
- |
| 16.3(Electric Strength (after clause 15 and 16.2)) |
- |
5000 |
|
15% discount offered to samples received from BIS. |
| 16.2(Leakage Current (after Clause 15)) |
- |
5000 |
|
15% discount offered to samples received from BIS. |
| 16.1(General) |
- |
0 |
|
- |
| 16.0(General) |
- |
0 |
|
- |
| 15.3(Humidity Test) |
- |
5000 |
|
15% discount offered to samples received from BIS. |
| 15.2(Spillage Test) |
- |
0 |
|
- |
| 15.1(Ingress Protection test other than IPX0 (IP test)) |
- |
5000 |
|
15% discount offered to samples received from BIS. |
| 15.0(Moisture resistance) |
- |
0 |
|
- |
| 14(Transient Over Voltages) |
- |
5000 |
|
15% discount offered to samples received from BIS. |
| 13.3(Electric Strength at operating temperature) |
- |
2000 |
|
15% discount offered to samples received from BIS. |
| 13.2(Leakage current at operating temperature) |
- |
3000 |
|
15% discount offered to samples received from BIS. |
| 13(Leakage current and electric strength at operating temperature) |
- |
0 |
|
- |
| 11.3(Heating) |
- |
0 |
|
- |
| 11.2(General) |
- |
0 |
|
- |
| 11.1(General) |
- |
0 |
|
- |
| 10.2(Current input) |
- |
5000 |
|
15% discount offered to samples received from BIS. |
| 10.1(Power input) |
- |
5000 |
|
15% discount offered to samples received from BIS. |
| 9(Starting of motor operation test requirements and tests) |
- |
0 |
|
- |
| 8.1.4(Protection against live parts against protective impedance) |
- |
1000 |
|
15% discount offered to samples received from BIS. |
| 8.1.3(Protection against live parts in visible glowing heating elements) |
- |
1000 |
|
15% discount offered to samples received from BIS. |
| 8.1.2(Protection against live parts in openings) |
- |
1000 |
|
15% discount offered to samples received from BIS. |
| 8.1.1(Protection against live parts in all positions) |
- |
1000 |
|
15% discount offered to samples received from BIS. |
| 7(Marking and instructions) |
- |
0 |
|
- |
| 15.2(Moisture resistance) |
- |
0 |
|
Repeated subclause |
| 19.17(Abnormal Operation, IS 302-1) |
- |
0 |
|
- |
| 20.2(Stability & Mechanical Hazards, IS 302-1) |
- |
0 |
|
- |
| 21.2(Mechanical Strength, IS 302-1) |
- |
0 |
|
- |
| 21.3(Mechanical Strength, IS 302-1) |
- |
0 |
|
- |
| 22.5(Construction) |
- |
0 |
|
- |
| 22.6(Construction, IS 302-1) |
- |
0 |
|
- |
| 22.11(Construction, IS 302-1) |
- |
0 |
|
- |
| 22.16(Construction) |
- |
0 |
|
- |
| 22.32(Construction, IS 302-1) |
- |
0 |
|
- |
| 22.42(Construction) |
- |
0 |
|
- |
| 23.3(Internal Wiring, IS 302-1) |
- |
0 |
|
- |
| 25.6(Supply connection and external flexible cords, IS 302-1) |
- |
0 |
|
- |
| 25.7(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
- |
| 25.14(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
- |
| 25.15(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
- |
| 26.5(Terminals for external conductors) |
- |
0 |
|
- |
| 27.5(Provision for Earthing, IS 302-1) |
- |
0 |
|
- |
| 28.1(Screws and connections) |
- |
0 |
|
- |
| 22.2(Construction, IS 302-1) |
- |
0 |
|
- |
| 22.3(Construction, IS 302-1) |
- |
0 |
|
- |
| B.22.4(Construction, IS 302-1) |
- |
0 |
|
- |
| B.22.5(Construction, IS 302-1) |
- |
0 |
|
- |
| 6(Classification- IS 302-1) |
- |
0 |
|
- |
| 5(General conditions for the tests) |
- |
0 |
|
- |
| A.2(Earth continuity test) |
- |
0 |
|
- |
| Annex D(Thermal motor protectors) |
- |
0 |
|
- |
| 12(Charging of metal-ion batteries) |
- |
10000 |
|
15% discount offered to samples received from BIS. |
| 11.8(Temperature rise) |
- |
0 |
|
Repeated Entry |
| 11.7(Duration corresponding) |
- |
0 |
|
Repeated Entry |
| 11.6(Combined appliances) |
- |
0 |
|
Repeated Entry |
| 11.5(Motor-operated appliances) |
- |
0 |
|
Repeated Entry |
| 11.4(Heating appliances) |
- |
0 |
|
Repeated Entry |
| 8.1.5(Live parts of built-in appliances) |
- |
0 |
|
Repeated Entry |
| 18(Endurance) |
- |
0 |
|
Repeated Entry |
| 17(Overload protection of transformers and associated circuits) |
- |
0 |
|
Repeated Entry |
| 17(Over Load Protection of Transformers and associated circuits) |
- |
0 |
|
Repeated Entry |
| 16(Leakage current and electric strength) |
- |
0 |
|
Repeated Entry |
| 4(General requirement) |
- |
0 |
|
Repeated Entry |
| 31(Resistance to Rusting) |
- |
0 |
|
Repeated Entry |
| 30.2(Needle Flame Test) |
- |
0 |
|
Repeated Entry |
| 30.2(Glow Wire Test) |
- |
0 |
|
Repeated Entry |
| 30.1(Ball pressure test) |
- |
0 |
|
Repeated Entry |
| 29(clearance, creepage distances and solid insulation) |
- |
0 |
|
Repeated Entry |
| 28(Screw test and connections) |
- |
0 |
|
Repeated Entry |
| 27.1(Provision for Earthing, IS 302-1) |
- |
0 |
|
Repeated Entry |
| 26(Terminals for external conductors) |
- |
0 |
|
Repeated Entry |
| 25.8(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
Repeated Entry |
| 24(Components) |
- |
0 |
|
Repeated Entry |
| 23.1(Internal Wiring, IS 302-1) |
- |
0 |
|
Repeated Entry |
| 22.1(Construction, IS 302-1) |
- |
0 |
|
Repeated Entry |
| 21.1(Mechanical Strength, IS 302-1) |
- |
0 |
|
Repeated Entry |
| 20.1(Stability & Mechanical Hazards, IS 302-1) |
- |
0 |
|
Repeated Entry |
| 19(Abnormal Operation) |
- |
0 |
|
Repeated Entry |
| 18(Endurance) |
- |
0 |
|
Repeated Entry |
| 16.3(Electric Strength (after clause 15 and 16.2)) |
- |
0 |
|
Repeated Entry |
| 16.2(Leakage Current (after Clause 15)) |
- |
0 |
|
Repeated Entry |
| 16.1(General) |
- |
0 |
|
Repeated Entry |
| 16.0(General) |
- |
0 |
|
Repeated Entry |
| 15.3(Humidity Test) |
- |
0 |
|
Repeated Entry |
| 15.2(Spillage Test) |
- |
0 |
|
Repeated Entry |
| 15.1(Ingress Protection test other than IPX0 (IP test)) |
- |
0 |
|
Repeated Entry |
| 15.0(Moisture resistance) |
- |
0 |
|
Repeated Entry |
| 14(Transient Over Voltages) |
- |
0 |
|
Repeated Entry |
| 13.3(Electric Strength at operating temperature) |
- |
0 |
|
Repeated Entry |
| 13.2(Leakage current at operating temperature) |
- |
0 |
|
Repeated Entry |
| 13(Leakage current and electric strength at operating temperature) |
- |
0 |
|
Repeated Entry |
| 11.3(Heating) |
- |
0 |
|
Repeated Entry |
| 11.2(General) |
- |
0 |
|
Repeated Entry |
| 11.1(General) |
- |
0 |
|
Repeated Entry |
| 10.2(Current input) |
- |
0 |
|
Repeated Entry |
| 10.1(Power input) |
- |
0 |
|
Repeated Entry |
| 9(Starting of motor operation test requirements and tests) |
- |
0 |
|
Repeated Entry |
| 8.1.4(Protection against live parts against protective impedance) |
- |
0 |
|
Repeated Entry |
| 8.1.3(Protection against live parts in visible glowing heating elements) |
- |
0 |
|
Repeated Entry |
| 8.1.2(Protection against live parts in openings) |
- |
0 |
|
Repeated Entry |
| 8.1.1(Protection against live parts in all positions) |
- |
0 |
|
Repeated Entry |
| 7(Marking and instructions) |
- |
0 |
|
Repeated Entry |
| 15.2(Moisture resistance) |
- |
0 |
|
Repeated Entry |
| 19.17(Abnormal Operation, IS 302-1) |
- |
0 |
|
Repeated Entry |
| 20.2(Stability & Mechanical Hazards, IS 302-1) |
- |
0 |
|
Repeated Entry |
| 21.2(Mechanical Strength, IS 302-1) |
- |
0 |
|
Repeated Entry |
| 21.3(Mechanical Strength, IS 302-1) |
- |
0 |
|
Repeated Entry |
| 22.5(Construction) |
- |
0 |
|
Repeated Entry |
| 22.6(Construction, IS 302-1) |
- |
0 |
|
Repeated Entry |
| 22.11(Construction, IS 302-1) |
- |
0 |
|
Repeated Entry |
| 22.42(Construction) |
- |
0 |
|
Repeated Entry |
| 23.3(Internal Wiring, IS 302-1) |
- |
0 |
|
Repeated Entry |
| 25.6(Supply connection and external flexible cords, IS 302-1) |
- |
0 |
|
Repeated Entry |
| 25.7(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
Repeated Entry |
| 25.14(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
Repeated Entry |
| 25.15(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
Repeated Entry |
| 26.5(Terminals for external conductors) |
- |
0 |
|
Repeated Entry |
| 27.5(Provision for Earthing, IS 302-1) |
- |
0 |
|
Repeated Entry |
| 28.1(Screws and connections) |
- |
0 |
|
Repeated Entry |
| 22.2(Construction, IS 302-1) |
- |
0 |
|
Repeated Entry |
| 22.3(Construction, IS 302-1) |
- |
0 |
|
Repeated Entry |
| B.22.4(Construction, IS 302-1) |
- |
0 |
|
Repeated Entry |
| B.22.5(Construction, IS 302-1) |
- |
0 |
|
Repeated Entry |
| 6(Classification- IS 302-1) |
- |
0 |
|
Repeated Entry |
| 5(General conditions for the tests) |
- |
0 |
|
Repeated Entry |
| A.2(Earth continuity test) |
- |
0 |
|
Repeated Entry |
| Annex D(Thermal motor protectors) |
- |
0 |
|
Repeated Entry |
| 12(Charging of metal-ion batteries) |
- |
0 |
|
Repeated Entry |
| Annex C(Ageing test on motors) |
- |
0 |
|
Repeated Entry |
| Annex C(Ageing test on motors) |
- |
0 |
|
Repeated Entry |
|
27 Apr, 2029 |
- - |
| 1266 |
Intertek India Private Limited, New Delhi (E-26)
| 8136626
| IS 302 : Part 2 : Sec 3 (2007) |
Safety of household and similar electrical appliances: Part 2 particular requirements: Sec 3 electric iron (First Revision) |
- |
50000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 6(Classification- IS 302-1 ) |
- |
0 |
|
- |
| 6(Classification- IS 302-1) |
- |
0 |
|
- |
| 7.1(Marking- IS 302-1) |
- |
1000 |
|
- |
| 7.1(Marking- IS 302-1) |
- |
0 |
|
Repeated sub clause. |
| 7.1(Marking- IS 302-1) |
- |
0 |
|
Repeated sub clause. |
| 7.1(Marking- IS 302-1) |
- |
0 |
|
Repeated sub clause. |
| 7.1(Marking- IS 302-1) |
- |
0 |
|
Repeated sub clause. |
| 7.1(Marking- IS 302-1) |
- |
0 |
|
Repeated sub clause. |
| 7.1(Marking- IS 302-1) |
- |
0 |
|
Repeated sub clause. |
| 7.1(Marking- IS 302-1) |
- |
0 |
|
Repeated sub clause. |
| 7.1(Marking- IS 302-1) |
- |
0 |
|
Repeated sub clause. |
| 7.3(Marking- IS 302-1) |
- |
0 |
|
Repeated sub clause. |
| 7.4(Marking- IS 302-1) |
- |
0 |
|
Repeated sub clause. |
| 7.6(Marking- IS 302-1) |
- |
0 |
|
Repeated sub clause. |
| 7.7(Marking- IS 302-1) |
- |
0 |
|
Repeated sub clause. |
| 7.8(Marking- IS 302-1) |
- |
0 |
|
Repeated sub clause. |
| 7.11(Marking- IS 302-1) |
- |
0 |
|
Repeated sub clause. |
| 7.12(Marking- IS 302-1) |
- |
0 |
|
Repeated sub clause. |
| 7.13(Marking- IS 302-1) |
- |
0 |
|
Repeated sub clause. |
| 7.14(Marking- IS 302-1) |
- |
0 |
|
Repeated sub clause. |
| 7.15(Marking- IS 302-1) |
- |
0 |
|
Repeated sub clause. |
| 7.101(Marking) |
- |
0 |
|
Repeated sub clause. |
| 8( Protection Against Electric Shock, IS 302-1) |
- |
1000 |
|
- |
| 10(Power Input and Current, IS 302-1) |
- |
3000 |
|
- |
| 11(Heating, IS 302-1) |
- |
5000 |
|
- |
| 11(Heating, IS 302-1) |
- |
0 |
|
Repeated sub clause. |
| 11(Heating, IS 302-1) |
- |
0 |
|
Repeated sub clause. |
| 11(Heating, IS 302-1) |
- |
0 |
|
Repeated sub clause. |
| 11(Heating, IS 302-1) |
- |
0 |
|
Repeated sub clause. |
| 11(Heating, IS 302-1) |
- |
0 |
|
Repeated sub clause. |
| 11(Heating, IS 302-1) |
- |
0 |
|
Repeated sub clause. |
| 11(Heating, IS 302-1) |
- |
0 |
|
Repeated sub clause. |
| 13(Electrical Insulation and Leakage Current at Operating Temperature: Leakage current, IS 302-1) |
- |
2000 |
|
- |
| 13(Electrical Insulation and Leakage Current at Operating Temperature: High Voltage, IS 302-1) |
- |
2000 |
|
- |
| 14(Transient Over Voltages, IS 302-1) |
- |
3000 |
|
- |
| 15.1(Moisture Resistance, IS 302-1) |
- |
4000 |
|
- |
| 15.2(Moisture Resistance, IS 302-1) |
- |
0 |
|
Repeated sub clause. |
| 15.3(Moisture Resistance, IS 302-1) |
- |
0 |
|
Repeated sub clause. |
| 16(Electrical Insulation and Leakage Current at Operating Temperature: Leakage current, IS 302-1) |
- |
2000 |
|
- |
| 16(Electrical Insulation and Leakage Current at Operating Temperature: High Voltage, IS 302-1) |
- |
2000 |
|
- |
| 19.4(Abnormal Operation, IS 302-1) |
- |
5000 |
|
- |
| 19.4(Abnormal Operation, IS 302-1) |
- |
0 |
|
Repeated sub clause. |
| 19.5(Abnormal Operation, IS 302-1) |
- |
0 |
|
Repeated sub clause. |
| 19.5(Abnormal Operation, IS 302-1) |
- |
0 |
|
Repeated sub clause. |
| 19.7(Abnormal Operation) |
- |
0 |
|
Repeated sub clause. |
| 19.9(Abnormal Operation) |
- |
0 |
|
Repeated sub clause. |
| 19.1(Abnormal Operation) |
- |
0 |
|
Repeated sub clause. |
| 19.101(Abnormal Operation) |
- |
0 |
|
Repeated sub clause. |
| 20.1(Stability & Mechanical Hazards, IS 302-1) |
- |
1000 |
|
- |
| 20.2(Stability & Mechanical Hazards, IS 302-1) |
- |
0 |
|
Repeated sub clause. |
| 21.1(Mechanical Strength, IS 302-1) |
- |
1000 |
|
- |
| 21.2(Mechanical Strength, IS 302-1) |
- |
0 |
|
Repeated sub clause. |
| 21.101(Mechanical Strength, IS 302-2-3) |
- |
0 |
|
Repeated sub clause. |
| 22(Construction, IS 302-1) |
- |
3000 |
|
- |
| 22.101(Construction) |
- |
0 |
|
Repeated sub clause. |
| 22.102(Construction) |
- |
0 |
|
Repeated sub clause. |
| 22.103(Construction) |
- |
0 |
|
Repeated sub clause. |
| 22.104(Construction) |
- |
0 |
|
Repeated sub clause. |
| 22.105(Construction) |
- |
0 |
|
Repeated sub clause. |
| 22.106(Construction) |
- |
0 |
|
Repeated sub clause. |
| 22.107(Construction) |
- |
0 |
|
Repeated sub clause. |
| 23.1(Internal Wiring, IS 302-1) |
- |
1000 |
|
- |
| 23.2(Internal Wiring, IS 302-1) |
- |
0 |
|
Repeated sub clause. |
| 23.3(Internal Wiring, IS 302-1) |
- |
0 |
|
Repeated sub clause. |
| 23.4(Internal Wiring, IS 302-1) |
- |
0 |
|
Repeated sub clause. |
| 23.5(Internal Wiring, IS 302-1) |
- |
0 |
|
Repeated sub clause. |
| 23.6(Internal Wiring, IS 302-1) |
- |
0 |
|
Repeated sub clause. |
| 23.7(Internal Wiring, IS 302-1) |
- |
0 |
|
Repeated sub clause. |
| 23.8(Internal Wiring, IS 302-1) |
- |
0 |
|
Repeated sub clause. |
| 23.9(Internal Wiring, IS 302-1) |
- |
0 |
|
Repeated sub clause. |
| 23.10(Internal Wiring, IS 302-1) |
- |
0 |
|
Repeated sub clause. |
| 24.1(Components, IS 302-1) |
- |
2000 |
|
- |
| 24.2(Components, IS 302-1) |
- |
0 |
|
Repeated sub clause. |
| 24.4(Components, IS 302-1) |
- |
0 |
|
Repeated sub clause. |
| 24.5(Components, IS 302-1) |
- |
0 |
|
Repeated sub clause. |
| 24.6(Components, IS 302-1) |
- |
0 |
|
Repeated sub clause. |
| 25.1(Supply Connection and External Flexible Cords, IS 302-1) |
- |
1000 |
|
- |
| 25.5(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
Repeated sub clause. |
| 25.6(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
Repeated sub clause. |
| 25.7(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
Repeated sub clause. |
| 25.8(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
Repeated sub clause. |
| 26.9(Supply Connection and External Flexible Cords, IS 302-1) |
- |
1000 |
|
- |
| 25.1(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
Repeated sub clause. |
| 25.11(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
Repeated sub clause. |
| 25.12(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
Repeated sub clause. |
| 25.13(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
Repeated sub clause. |
| 25.14(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
Repeated sub clause. |
| 25.14(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
Repeated sub clause. |
| 25.15(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
Repeated sub clause. |
| 25.16(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
Repeated sub clause. |
| 25.17(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
Repeated sub clause. |
| 25.18(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
Repeated sub clause. |
| 25.19(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
Repeated sub clause. |
| 25.2(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
Repeated sub clause. |
| 25.21(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
Repeated sub clause. |
| 25.22(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
Repeated sub clause. |
| 26(Terminals for External Conductors, IS 302-1) |
- |
0 |
|
Repeated sub clause. |
| 27.1(Provision for Earthing, IS 302-1) |
- |
2000 |
|
- |
| 27.2(Provision for Earthing, IS 302-1) |
- |
0 |
|
Repeated sub clause. |
| 27.3(Provision for Earthing, IS 302-1) |
- |
0 |
|
Repeated sub clause. |
| 27.4(Provision for Earthing, IS 302-1) |
- |
0 |
|
Repeated sub clause. |
| 27.5(Provision for Earthing, IS 302-1) |
- |
0 |
|
Repeated sub clause. |
| 28(Screws & Connections, IS 302-1) |
- |
1000 |
|
- |
| 29.1(Clearances, Creepage distances and Solid Insulation, IS 302-1) |
- |
2000 |
|
- |
| 29.2(Clearances, Creepage distances and Solid Insulation, IS 302-1) |
- |
0 |
|
Repeated sub clause. |
| 30.1(Resistance to Heat, Fire & Tracking, IS 302-1) |
- |
3000 |
|
- |
| 30.2(Resistance to Heat, Fire & Tracking, IS 302-1) |
- |
0 |
|
Repeated sub clause. |
| 31(Resistance of Rusting, IS 302-1) |
- |
0 |
|
Repeated sub clause. |
| 4(General requirement) |
- |
0 |
|
Repeated sub clause. |
| 16(Leakage current and electric strength) |
- |
0 |
|
Repeated sub clause. |
| 17(Overload protection of transformers and associated circuits) |
- |
2000 |
|
- |
| 17(Overload protection of transformers and associated circuits) |
- |
0 |
|
Repeated sub clause. |
| 17(Overload protection of transformers and associated circuits) |
- |
0 |
|
Repeated sub clause. |
| 19.11.4.1(Electrostatic discharges) |
- |
0 |
|
Repeated sub clause. |
| 5(GENERAL CONDITIONS FOR THE TESTS) |
- |
0 |
|
Repeated sub clause. |
| 19(Abnormal operation) |
- |
0 |
|
Repeated clause. |
| 25(Supply Connection and External Flexible Cords) |
- |
0 |
|
Repeated clause. |
| 18(Endurance) |
- |
0 |
|
Repeated clause. |
|
27 Apr, 2029 |
- - |
| 1267 |
Intertek India Private Limited, New Delhi (E-26)
| 8136626
| IS 16333 : Part 3 (2022) |
Mobile phone handsets: Part 3 Indian language support for mobile phone handsets - Specific requirements(Second Revision) |
- |
31350 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 5.1(Inputting of text) |
- |
21350 |
|
15 % discount to BIS. |
| 5.2(Message Readability) |
- |
10000 |
|
15 % discount to BIS. |
| 6(Marking) |
- |
0 |
|
Not Applicable |
|
27 Apr, 2029 |
- - |
| 1268 |
Intertek India Private Limited, New Delhi (E-26)
| 8136626
| IS 302 : Part 1 (2008) |
Safety of household and similar electrical appliances: Part 1 general requirements (Sixth Revision) |
- |
154000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 7(Marking and instructions) |
- |
0 |
|
Not Applicable |
| 8.1.1(Protection against live parts in all positions) |
- |
2000 |
|
15% discount offered to samples received from BIS. |
| 8.1.2(Protection against live parts in openings) |
- |
1000 |
|
15% discount offered to samples received from BIS. |
| 8.1.3(Protection against live parts in visible glowing heating elements) |
- |
1000 |
|
15% discount offered to samples received from BIS. |
| 8.1.4(Protection against live parts against protective impedance) |
- |
1000 |
|
15% discount offered to samples received from BIS. |
| 9(Starting of motor operation test requirements and tests) |
- |
0 |
|
Not Applicable |
| 10.1(Power input) |
- |
5000 |
|
15% discount offered to samples received from BIS. |
| 10.2(Current input) |
- |
5000 |
|
15% discount offered to samples received from BIS. |
| 11.1(General) |
- |
0 |
|
Not Applicable |
| 11.2(General) |
- |
0 |
|
Not Applicable |
| 11.3(Heating) |
- |
20000 |
|
Not Applicable |
| 13.1(General) |
- |
0 |
|
Not Applicable |
| 13.2(Leakage current at operating temperature) |
- |
3000 |
|
15% discount offered to samples received from BIS. |
| 13.3(Electric Strength at operating temperature) |
- |
2000 |
|
Not Applicable |
| 14(Transient Over Voltages) |
- |
5000 |
|
15% discount offered to samples received from BIS. |
| 15.0(General) |
- |
0 |
|
Not Applicable |
| 15.1(Ingress Protection test other than IPX0 (IP test)) |
- |
5000 |
|
15% discount offered to samples received from BIS. |
| 15.2(Spillage Test) |
- |
0 |
|
Not Applicable |
| 15.3(Humidity Test) |
- |
5000 |
|
15% discount offered to samples received from BIS. |
| 16.0(General) |
- |
0 |
|
Not Applicable |
| 16.1(General) |
- |
0 |
|
15% discount offered to samples received from BIS. |
| 16.2(Leakage Current (after Clause 15)) |
- |
5000 |
|
15% discount offered to samples received from BIS. |
| 16.3(Electric Strength (after clause 15 and 16.2)) |
- |
5000 |
|
Not Applicable |
| 17(Over Load Protection of Transformers and associated circuits) |
- |
10000 |
|
15% discount offered to samples received from BIS. |
| 18(Endurance Test requirements and tests) |
- |
0 |
|
Not Applicable |
| 19(Abnormal Operation) |
- |
20000 |
|
15% discount offered to samples received from BIS. |
| 20(Stability test) |
- |
5000 |
|
15% discount offered to samples received from BIS. |
| 21(Mechanical Strength Test) |
- |
5000 |
|
15% discount offered to samples received from BIS. |
| 22(Construction verification related test) |
- |
10000 |
|
15% discount offered to samples received from BIS. |
| 23(General) |
- |
0 |
|
Not Applicable |
| 24(Components) |
- |
0 |
|
Not Applicable |
| 25(Supply connection and external flexible cords) |
- |
2000 |
|
15% discount offered to samples received from BIS. |
| 26(Terminals for external conductors) |
- |
2000 |
|
15% discount offered to samples received from BIS. |
| 27(Provision for earthing) |
- |
5000 |
|
15% discount offered to samples received from BIS. |
| 28(Screw test and connections) |
- |
5000 |
|
15% discount offered to samples received from BIS. |
| 29(clearance, creepage distances and solid insulation) |
- |
5000 |
|
15% discount offered to samples received from BIS. |
| 30.1(Ball pressure test) |
- |
10000 |
|
15% discount offered to samples received from BIS. |
| 30.2(Glow Wire Test) |
- |
5000 |
|
15% discount offered to samples received from BIS. |
| 30.2(Needle Flame Test) |
- |
5000 |
|
15% discount offered to samples received from BIS. |
| 31(Resistance to Rusting) |
- |
0 |
|
Not Applicable |
| 32(Radiation Toxicity and Similar Hazards) |
- |
0 |
|
Not Applicable |
|
27 Apr, 2029 |
- - |
| 1269 |
Intertek India Private Limited, New Delhi (E-26)
| 8136626
| IS 302 : Part 2 : Sec 15 (2009) |
Safety of household and similar electrical appliances: Part 2 particular requirements: Sec 15 appliances for heating liquids (First Revision) |
- |
15237 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 6.0(Classification) |
- |
0 |
|
N/A |
| 7(Marking and instructions) |
- |
0 |
|
Not Applicable |
| 8(Protection against live parts) |
- |
500 |
|
15% discount offered to samples received from BIS. |
| 9(STARTING OF MOTOR-OPERATED APPLIANCES) |
- |
0 |
|
Not Applicable |
| 10(POWER INPUT AND CURRENT) |
- |
1000 |
|
15% discount offered to samples received from BIS. |
| 11(HEATING) |
- |
2000 |
|
15% discount offered to samples received from BIS. |
| 13(LEAKAGE CURRENT AND ELECTRIC STRENGTH AT OPERATING TEMPERATURE) |
- |
500 |
|
15% discount offered to samples received from BIS. |
| 14(TRANSIENT OVERVOLTAGES) |
- |
500 |
|
15% discount offered to samples received from BIS. |
| 15(MOISTURE RESISTANCE) |
- |
1000 |
|
15 % discount to BIS. |
| 16(LEAKAGE CURRENT AND ELECTRIC STRENGTH) |
- |
1000 |
|
15 % discount to BIS. |
| 17(OVERLOAD PROTECTION OF TRANSFORMERS AND ASSOCIATED CIRCUITS) |
- |
1000 |
|
15 % discount to BIS. |
| 18(ENDURANCE) |
- |
0 |
|
Not Applicable |
| 19(ABNORMAL OPERATION) |
- |
1500 |
|
15% discount offered to samples received from BIS. |
| 20(STABILITY AND MECHANICAL HAZARDS) |
- |
500 |
|
15% discount offered to samples received from BIS. |
| 21(MECHANICAL STRENGTH) |
- |
500 |
|
15 % discount to BIS. |
| 22(CONSTRUCTION) |
- |
1000 |
|
15 % discount to BIS. |
| 23(INTERNAL WIRING) |
- |
0 |
|
Not Applicable |
| 24(COMPONENTS) |
- |
0 |
|
Not Applicable |
| 25(SUPPLY CONNECTION AND EXTERNAL FLEXIBLE CORDS) |
- |
500 |
|
15 % discount to BIS. |
| 26(TERMINALS FOR EXTERNAL CONDUCTORS) |
- |
500 |
|
15% discount offered to samples received from BIS. |
| 27(PROVISION FOR EARTHING) |
- |
500 |
|
15 % discount to BIS. |
| 28(SCREWS AND CONNECTIONS) |
- |
500 |
|
15% discount offered to samples received from BIS. |
| 29(CLEARANCES, CREEPAGE DISTANCES AND SOLID INSULATION) |
- |
500 |
|
15% discount offered to samples received from BIS. |
| 30(RESISTANCE TO HEAT AND FIRE) |
- |
1737 |
|
15% discount offered to samples received from BIS. |
| 31(RESISTANCE TO RUSTING) |
- |
0 |
|
Not Applicable |
| 32(RADIATION, TOXICITY AND SIMILAR HAZARDS) |
- |
0 |
|
Not Applicable |
|
27 Apr, 2029 |
- - |
| 1270 |
Intertek India Private Limited, New Delhi (E-26)
| 8136626
| IS 10322 : Part 5 : Sec 1 (2012) |
Luminaires: Part 5 particular requirements: Sec 1 fixed general purpose luminaires (First Revision) |
- |
104000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 6.0(Marking) |
- |
0 |
|
- |
| 7.0(Construction) |
- |
5000 |
|
15% discount offered to samples received from BIS. |
| 8.0(Creepage Distance and Clearances) |
- |
5000 |
|
15% discount offered to samples received from BIS. |
| 9.0(Provision for earthing) |
- |
5000 |
|
15% discount offered to samples received from BIS. |
| 10.0(Terminals) |
- |
5000 |
|
15% discount offered to samples received from BIS. |
| 11.0(External & Internal Wiring) |
- |
5000 |
|
15% discount offered to samples received from BIS. |
| 12.0(Protection against electric shock) |
- |
5000 |
|
15% discount offered to samples received from BIS. |
| 13.0(Endurance Tests and Thermal Tests) |
- |
20000 |
|
15% discount offered to samples received from BIS. |
| 14.0(Resistance to Dust & Moisture) |
- |
14000 |
|
15% discount offered to samples received from BIS. |
| 15.0(Insulation Resistance and Electric Strength) |
- |
10000 |
|
15% discount offered to samples received from BIS. |
| 16.0(Resistance to Heat , fire and tracking) |
- |
20000 |
|
15% discount offered to samples received from BIS. |
| 4(General Test Requireements) |
- |
0 |
|
- |
| 5(Classification of Luminaires') |
- |
0 |
|
- |
| 17.0(Photometric Test) |
- |
10000 |
|
15% discount offered to samples received from BIS. |
|
27 Apr, 2029 |
- - |
| 1271 |
Intertek India Private Limited, New Delhi (E-26)
| 8136626
| IS 10322 : Part 5 : Sec 2 (2012) |
Luminaires: Part 5 particular requirements: Sec 2 recessed luminaires (First Revision) |
- |
68800 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 6(Marking) |
- |
0 |
|
- |
| 7(Construction) |
- |
3000 |
|
15% discount offered to samples received from BIS. |
| 8(Creepage Distance and Clearances) |
- |
3000 |
|
15% discount offered to samples received from BIS. |
| 9(Provision for earthing) |
- |
3008 |
|
15% discount offered to samples received from BIS. |
| 10(Terminals) |
- |
3000 |
|
15% discount offered to samples received from BIS. |
| 11(External & Internal Wiring) |
- |
3000 |
|
15% discount offered to samples received from BIS. |
| 12(Protection against electric shock) |
- |
7000 |
|
15% discount offered to samples received from BIS. |
| 13(Endurance Tests and Thermal Tests) |
- |
19000 |
|
15% discount offered to samples received from BIS. |
| 14(Resistance to Dust and Moisture) |
- |
8000 |
|
15% discount offered to samples received from BIS. |
| 15(Insulation Resistance and Electric Strength) |
- |
5000 |
|
15% discount offered to samples received from BIS. |
| 16(Resistance to Heat , fire and tracking) |
- |
5000 |
|
15% discount offered to samples received from BIS. |
| 17(Photometric Test) |
- |
9800 |
|
15% discount offered to samples received from BIS. |
| 4(General Test Requireements) |
- |
0 |
|
- |
| 5(Classification of Luminaires') |
- |
0 |
|
- |
|
27 Apr, 2029 |
- - |
| 1272 |
Intertek India Private Limited, New Delhi (E-26)
| 8136626
| IS 10322 : PART 5 : SEC 3 (2012) |
Luminaires: Part 5 particular requirements: Sec 3 luminaires for road and street lighting (First Revision) |
- |
104000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 6.0(Marking) |
- |
0 |
|
- |
| 7.0(Construction) |
- |
5000 |
|
15% discount offered to samples received from BIS. |
| 8.0(Creepage Distance and Clearances) |
- |
5000 |
|
15% discount offered to samples received from BIS. |
| 9.0(Provision for earthing) |
- |
5000 |
|
15% discount offered to samples received from BIS. |
| 10.0(Terminals) |
- |
5000 |
|
15% discount offered to samples received from BIS. |
| 11.0(External & Internal Wiring) |
- |
5000 |
|
15% discount offered to samples received from BIS. |
| 12.0(Protection against electric shock) |
- |
10000 |
|
15% discount offered to samples received from BIS. |
| 13.0(Endurance Tests and Thermal Tests) |
- |
25000 |
|
15% discount offered to samples received from BIS. |
| 14.0(Resistance to Dust & Moisture) |
- |
14000 |
|
15% discount offered to samples received from BIS. |
| 15.0(Insulation Resistance and Electric Strength) |
- |
10000 |
|
15% discount offered to samples received from BIS. |
| 16.0(Resistance to Heat , fire and tracking) |
- |
10000 |
|
15% discount offered to samples received from BIS. |
| 17.0(Photometric Test) |
- |
10000 |
|
15% discount offered to samples received from BIS. |
| 4(General Test Requireements) |
- |
0 |
|
- |
| 5(Classification of Luminaires') |
- |
0 |
|
- |
|
27 Apr, 2029 |
- - |
| 1273 |
Intertek India Private Limited, New Delhi (E-26)
| 8136626
| IS 15885 : Part 2 : Sec 13 (2012) |
Safety of lamp controlgear: Part 2 particular requirements: Sec 13 d.c. or a.c. supplied electronic controlgear for led modules |
- |
185000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 7(Marking) |
- |
0 |
|
- |
| 8(Protection against accidental contact with live parts) |
- |
10000 |
|
15% discount offered to samples received from BIS. |
| 9(Terminals) |
- |
10000 |
|
15% discount offered to samples received from BIS. |
| 10(PROVISION FOR EARTHING) |
- |
10000 |
|
15% discount offered to samples received from BIS. |
| 11(MOISTURE RESISTANCE) |
- |
20000 |
|
15% discount offered to samples received from BIS. |
| 12(Electric Strength) |
- |
7000 |
|
15% discount offered to samples received from BIS. |
| 14(Fault conditions) |
- |
35000 |
|
15% discount offered to samples received from BIS. |
| 15(Transformer heating) |
- |
30000 |
|
15% discount offered to samples received from BIS. |
| 17(Creepage distance and clearances) |
- |
6500 |
|
15% discount offered to samples received from BIS. |
| 18(Screws, current carrying parts and connections) |
- |
6500 |
|
15% discount offered to samples received from BIS. |
| 19(Resistance to heat, fire and tracking) |
- |
25000 |
|
15% discount offered to samples received from BIS. |
| 20(Resistance to corrosion) |
- |
25000 |
|
15% discount offered to samples received from BIS. |
| 13(Thermal endurance test for winding of ballasts) |
- |
0 |
|
- |
| 16(Construction) |
- |
0 |
|
- |
|
27 Apr, 2029 |
- - |
| 1274 |
Intertek India Private Limited, New Delhi (E-26)
| 8136626
| IS 16102 : Part 1 (2012) |
Self - Ballasted led lamps for general lighting services: Part 1 safety requirements |
- |
43875 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 5(Marking) |
- |
0 |
|
- |
| 6(Interchangeability) |
- |
5000 |
|
15% discount offered to samples received from BIS.
Restricted to Cap typ B22d,E27 & E14 only. |
| 7(Protection against accidental contact with live parts) |
- |
2000 |
|
15% discount offered to samples received from BIS.
Restricted to Cap typ B22d,E27 & E14 only. |
| 8(Insulation Resistance and Electric Strength) |
- |
8000 |
|
15% discount offered to samples received from BIS.
Restricted to Cap typ B22d,E27 & E14 only. |
| 9(MECHANICAL STRENGTH) |
- |
2000 |
|
15% discount offered to samples received from BIS.
Restricted to Cap typ B22d,E27 & E14 only. |
| 10(cap temperature) |
- |
5000 |
|
15% discount offered to samples received from BIS.
Restricted to Cap typ B22d,E27 & E14 only. |
| 11(Resistance to Heat) |
- |
4000 |
|
15% discount offered to samples received from BIS.
Restricted to Cap typ B22d,E27 & E14 only. |
| 12(Resistance to Flame and Ignition) |
- |
4000 |
|
15% discount offered to samples received from BIS.
Restricted to Cap typ B22d,E27 & E14 only. |
| 13(Fault conditions) |
- |
8000 |
|
15% discount offered to samples received from BIS.
Restricted to Cap typ B22d,E27 & E14 only. |
| 14(Creepage distance and clearances) |
- |
5875 |
|
15% discount offered to samples received from BIS.
Restricted to Cap typ B22d,E27 & E14 only. |
|
27 Apr, 2029 |
- - |
| 1275 |
Intertek India Private Limited, New Delhi (E-26)
| 8136626
| IS 16103 : Part 1 (2012) |
Led modules for general lighting: Part 1 safety requirements |
- |
37500 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 7(Marking) |
- |
0 |
|
- |
| 8(Terminals) |
- |
2000 |
|
15% discount offered to samples received from BIS. |
| 9(PROVISION FOR EARTHING) |
- |
2000 |
|
15% discount offered to samples received from BIS. |
| 10(Protection against accidental contact with live parts) |
- |
3000 |
|
15% discount offered to samples received from BIS. |
| 11(Mositure Resistance and Insulation) |
- |
6000 |
|
15% discount offered to samples received from BIS. |
| 12(Electric Strength) |
- |
3000 |
|
15% discount offered to samples received from BIS. |
| 13(Fault conditions) |
- |
7000 |
|
15% discount offered to samples received from BIS. |
| 15(Construction) |
- |
2500 |
|
15% discount offered to samples received from BIS. |
| 16(Creepage distance and clearances) |
- |
2000 |
|
15% discount offered to samples received from BIS. |
| 17(Screws, current carrying parts and connections) |
- |
2000 |
|
15% discount offered to samples received from BIS. |
| 18(Resistance to heat, fire and tracking) |
- |
5000 |
|
15% discount offered to samples received from BIS. |
| 19(Resistance to corrosion) |
- |
3000 |
|
15% discount offered to samples received from BIS. |
|
27 Apr, 2029 |
- - |
| 1276 |
Intertek India Private Limited, New Delhi (E-26)
| 8136626
| IS 10322 : Part 5 : Sec 5 (2013) |
Luminaires: Part 5 particular requirements: Sec 5 floodlights (First Revision) |
- |
68800 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 6.0(Marking) |
- |
0 |
|
- |
| 7.0(Construction) |
- |
3000 |
|
15% discount offered to samples received from BIS. |
| 8.0(Creepage Distance and Clearances) |
- |
3000 |
|
15% discount offered to samples received from BIS. |
| 9.0(Provision for earthing) |
- |
3000 |
|
15% discount offered to samples received from BIS. |
| 10.0(Terminals) |
- |
3000 |
|
15% discount offered to samples received from BIS. |
| 11.0(External & Internal Wiring) |
- |
3000 |
|
15% discount offered to samples received from BIS. |
| 12.0(Protection against electric shock) |
- |
8000 |
|
15% discount offered to samples received from BIS. |
| 13.0(Endurance Tests and Thermal Tests) |
- |
15000 |
|
15% discount offered to samples received from BIS. |
| 14.0(Resistance to Dust & Moisture) |
- |
8000 |
|
15% discount offered to samples received from BIS. |
| 15.0(Insulation Resistance and Electric Strength) |
- |
7000 |
|
15% discount offered to samples received from BIS. |
| 16.0(Resistance to Heat , fire and tracking) |
- |
7000 |
|
15% discount offered to samples received from BIS. |
| 17.0(Photometric Test) |
- |
8800 |
|
15% discount offered to samples received from BIS. |
| 4(General Test Requireements) |
- |
0 |
|
- |
| 5(Classification of Luminaires') |
- |
0 |
|
- |
|
27 Apr, 2029 |
- - |
| 1277 |
Intertek India Private Limited, New Delhi (E-26)
| 8136626
| IS 10322 : Part 5 : Sec 6 (2013) |
Luminaires: Part 5 particular requirements: Sec 6 handlamps |
- |
87879 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 6.0(Marking) |
- |
0 |
|
N/A |
| 7.0(Construction) |
- |
4000 |
|
15% discount offered to samples received from BIS. |
| 8.0(Creepage Distance and Clearances) |
- |
4000 |
|
15% discount offered to samples received from BIS. |
| 9.0(Provision for earthing) |
- |
4000 |
|
15% discount offered to samples received from BIS. |
| 10.0(Terminals) |
- |
4000 |
|
15% discount offered to samples received from BIS. |
| 11.0(External & Internal Wiring) |
- |
4000 |
|
15% discount offered to samples received from BIS. |
| 12.0(Protection against electric shock) |
- |
8000 |
|
15% discount offered to samples received from BIS. |
| 13.0(Endurance Tests and Thermal Tests) |
- |
22000 |
|
15% discount offered to samples received from BIS. |
| 14.0(Resistance to Dust & Moisture) |
- |
11879 |
|
15% discount offered to samples received from BIS. |
| 15.0(Insulation Resistance and Electric Strength) |
- |
8000 |
|
15% discount offered to samples received from BIS. |
| 16.0(Resistance to Heat , fire and tracking) |
- |
18000 |
|
15% discount offered to samples received from BIS. |
| 8.2(Packing -Each Package shall bear the following Particulars) |
- |
0 |
|
N/A |
| 4(General Test Requireements) |
- |
0 |
|
N/A |
| 5(Classification of Luminaires') |
- |
0 |
|
N/A |
|
27 Apr, 2029 |
- - |
| 1278 |
Intertek India Private Limited, New Delhi (E-26)
| 8136626
| IS 16270 (2014) |
Secondary cells and batteries for solar photovoltaic application - General requirements and methods of test |
- |
1788150 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 8.1(Capacity test) |
- |
22500 |
|
15% discount offered to samples received from BIS. |
| 8.2(Endurance test) |
- |
638150 |
|
15% discount offered to samples received from BIS. |
| 8.3(Charge retention test) |
- |
270000 |
|
15% discount offered to samples received from BIS. |
| 8.4(Cycle endurance in Photovoltaic application) |
- |
750000 |
|
15% discount offered to samples received from BIS. |
| 8.5(Sulphation Test) |
- |
70000 |
|
15% discount offered to samples received from BIS. |
| 8.6(Water loss test) |
- |
37500 |
|
15% discount offered to samples received from BIS. |
| 4(Condition of use) |
- |
0 |
|
Not Applicable. |
| 5.1(Mechanical Endurance) |
- |
0 |
|
Not Applicable. |
| 5.2(Charge efficiency) |
- |
0 |
|
Not Applicable. |
| 5.3(Deep discharge protection) |
- |
0 |
|
Not Applicable. |
| 5.4(Marking) |
- |
0 |
|
Not Applicable. |
| 5.5(Dafety) |
- |
0 |
|
Not Applicable. |
| 5.6(Documentation) |
- |
0 |
|
Not Applicable. |
| 6(Finctional Characteristics) |
- |
0 |
|
Not Applicable. |
| 7(General test conditions) |
- |
0 |
|
Not Applicable. |
| 8.7(Non spillability) |
- |
0 |
|
Not Applicable. |
|
27 Apr, 2029 |
- - |
| 1279 |
Intertek India Private Limited, New Delhi (E-26)
| 8136626
| IS 616 (2017) |
Audio, video and similar electronic apparatus - Safety requirements (Fifth Revision) |
- |
170000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 5(Marking and instructions) |
- |
2000 |
|
15% discount offered to samples received from BIS. |
| 6(Hazardous radiations) |
- |
0 |
|
Not Applicable |
| 7(Heating under normal operating conditions) |
- |
25000 |
|
15% discount offered to samples received from BIS. |
| 8(Constructional requirements with regard to the protection against electric shock) |
- |
10000 |
|
15% discount offered to samples received from BIS. |
| 9(Electric shock hazard under normal operating conditions) |
- |
10000 |
|
15% discount offered to samples received from BIS. |
| 10(Insulation requirements) |
- |
25000 |
|
15% discount offered to samples received from BIS. |
| 11(Fault conditions) |
- |
15000 |
|
15% discount offered to samples received from BIS. |
| 12(Mechanical strength) |
- |
38000 |
|
15% discount offered to samples received from BIS. |
| 13(CLEARANCES and CREEPAGE DISTANCES) |
- |
10000 |
|
15% discount offered to samples received from BIS. |
| 15(TERMINALS) |
- |
5000 |
|
15% discount offered to samples received from BIS. |
| 16(External flexible cords) |
- |
5000 |
|
15% discount offered to samples received from BIS. |
| 17(Electrical connections and mechanical fixings) |
- |
5000 |
|
15% discount offered to samples received from BIS. |
| 19(Stability and mechanical hazards) |
- |
10000 |
|
15% discount offered to samples received from BIS. |
| 20(Resistance to fire) |
- |
5000 |
|
15% discount offered to samples received from BIS. |
| 14(Components) |
- |
0 |
|
15% discount offered to samples received from BIS. |
|
27 Apr, 2029 |
- - |
| 1280 |
Intertek India Private Limited, New Delhi (E-26)
| 8136626
| IS 10322 : Part 5 : Sec 7 (2017) |
Luminaires: Part 5 particular requirements: Sec 7 lighting chains (First Revision) |
- |
56625 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 20.6(Marking) |
- |
0 |
|
- |
| 20.7(Construction) |
- |
3000 |
|
15% discount offered to samples received from BIS. |
| 20.8(Creepage Distance and Clearances) |
- |
3000 |
|
15% discount offered to samples received from BIS. |
| 20.9(Provision for earthing) |
- |
3000 |
|
15% discount offered to samples received from BIS. |
| 20.10(Terminals) |
- |
3000 |
|
15% discount offered to samples received from BIS. |
| 20.11(External & Internal Wiring) |
- |
3000 |
|
15% discount offered to samples received from BIS. |
| 20.12(Protection against electric shock) |
- |
6000 |
|
15% discount offered to samples received from BIS. |
| 20.13(Endurance Tests and Thermal Tests) |
- |
12000 |
|
15% discount offered to samples received from BIS. |
| 20.14(Resistance to Dust & Moisture) |
- |
8000 |
|
15% discount offered to samples received from BIS. |
| 20.15(Insulation Resistance and Electric Strength) |
- |
6000 |
|
15% discount offered to samples received from BIS. |
| 20.16(Resistance to Heat , fire and tracking) |
- |
9625 |
|
15% discount offered to samples received from BIS. |
| 20.4(General Test Requireements) |
- |
0 |
|
- |
| 20.5(Classification of Luminaires') |
- |
0 |
|
- |
|
27 Apr, 2029 |
- - |
| 1281 |
Intertek India Private Limited, New Delhi (E-26)
| 8136626
| IS 16046 : Part 1 (2018) |
Secondary Cells and Batteries Containing Alkaline or Other Non-Acid Electrolytes ” Safety Requirements for Portable Sealed Secondary Cells and for Batteries Made from Them for Use in Portable Applications Part 1 Nickel Systems ( Second Revision ) |
- |
275000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 7.1(Charging procedure for test purposes) |
- |
25000 |
|
15% discount offered to samples received from BIS. |
| 7.2(Intended Use) |
- |
110000 |
|
15% discount offered to samples received from BIS. |
| 7.3(Reasonably foreseeable misuse) |
- |
100000 |
|
15% discount offered to samples received from BIS. |
| 5.2(Insulation and Wiring) |
- |
2500 |
|
15% discount offered to samples received from BIS. |
| 8.2(Small Cell and battery safety information) |
- |
30000 |
|
15% discount offered to samples received from BIS. |
| 9.3(Caution for ingestion of small cells and batteries) |
- |
7500 |
|
15% discount offered to samples received from BIS. |
| 4(Parameter Measurement Tolerances) |
- |
0 |
|
Not Applicable |
| 5(General Safety Considerations) |
- |
0 |
|
Not Applicable |
| 5.1(General) |
- |
0 |
|
Not Applicable |
| 5.3(Venting) |
- |
0 |
|
Not Applicable |
| 5.4(Temperature, Voltage and Current Management) |
- |
0 |
|
Not Applicable |
| 5.5(Terminal Contacts) |
- |
0 |
|
Not Applicable |
| 5.6(Assembly of Cells into batteries) |
- |
0 |
|
Not Applicable |
| 5.7(Quality Plan) |
- |
0 |
|
Not Applicable |
| 7(Specific requirements and tests) |
- |
0 |
|
Not Applicable |
| 8(Information for safety) |
- |
0 |
|
Not Applicable |
| 8.1(General) |
- |
0 |
|
Not Applicable |
| 9(Marking) |
- |
0 |
|
Not Applicable |
| 9.1(Cell Marking) |
- |
0 |
|
Not Applicable |
| 9.2(Battery Marking) |
- |
0 |
|
Not Applicable |
| 9.4(Other information) |
- |
0 |
|
Not Applicable |
| 10(Packaging) |
- |
0 |
|
Not Applicable |
| 6(Tyoe Test amd Sample Size) |
- |
0 |
|
Not Applicable |
|
27 Apr, 2029 |
- - |
| 1282 |
Intertek India Private Limited, New Delhi (E-26)
| 8136626
| IS 13252 : Part 1 (2010) |
Information technology equipment - Safety: Part 1 general requirements (Second Revision) |
- |
175000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 1.6(Power interface .) |
- |
5000 |
|
15% discount offered to samples received from BIS. |
| 1.7(Markings and instructions) |
- |
2000 |
|
15% discount offered to samples received from BIS. |
| 2.1(Protection from electric shock and energy hazards) |
- |
13000 |
|
15% discount offered to samples received from BIS. |
| 2.2(SELV circuits) |
- |
3000 |
|
15% discount offered to samples received from BIS. |
| 2.3(TNV circuits) |
- |
2000 |
|
15% discount offered to samples received from BIS. |
| 2.4(Limited current circuits) |
- |
3000 |
|
15% discount offered to samples received from BIS. |
| 2.5(Limited power sources .) |
- |
3000 |
|
15% discount offered to samples received from BIS. |
| 2.6(Provisions for earthing and bonding) |
- |
3000 |
|
15% discount offered to samples received from BIS. |
| 2.7(Overcurrent and earth fault protection in primary circuits) |
- |
3000 |
|
15% discount offered to samples received from BIS. |
| 2.9(Electrical insulation) |
- |
17000 |
|
15% discount offered to samples received from BIS. |
| 2.10(Clearances, creepage distances and distances through insulation) |
- |
11000 |
|
15% discount offered to samples received from BIS. |
| 3.1(General) |
- |
0 |
|
Not Applicable. |
| 3.2(Connection to a mains supply) |
- |
2000 |
|
15% discount offered to samples received from BIS. |
| 3.3(Wiring terminals for connection of external conductors) |
- |
2000 |
|
15% discount offered to samples received from BIS. |
| 3.4(Disconnection from the mains supply) |
- |
2000 |
|
15% discount offered to samples received from BIS. |
| 3.5(Interconnection of equipment) |
- |
3000 |
|
15% discount offered to samples received from BIS. |
| 4.1(Stability) |
- |
2000 |
|
15% discount offered to samples received from BIS. |
| 4.2(Mechanical strength) |
- |
14000 |
|
15% discount offered to samples received from BIS. |
| 4.3(Design and construction) |
- |
12000 |
|
15% discount offered to samples received from BIS. |
| 4.4(Protection against hazardous moving parts) |
- |
3000 |
|
15% discount offered to samples received from BIS. |
| 4.5(Thermal requirements) |
- |
25000 |
|
15% discount offered to samples received from BIS. |
| 4.6(Openings in enclosures) |
- |
2000 |
|
15% discount offered to samples received from BIS. |
| 4.7(Resistance to fire) |
- |
5000 |
|
15% discount offered to samples received from BIS. |
| 5.1(Touch current and protective conductor curren) |
- |
5000 |
|
15% discount offered to samples received from BIS. |
| 5.2(Electric strength) |
- |
5000 |
|
15% discount offered to samples received from BIS. |
| 5.3(Abnormal operating and fault conditions) |
- |
15000 |
|
15% discount offered to samples received from BIS. |
| 6.1(Protection of telecommunication network service persons, and users of other equipment connected to the network, from hazards in the equipment) |
- |
3000 |
|
15% discount offered to samples received from BIS. |
| 6.2(Protection of equipment users from overvoltages on networks telecommunication) |
- |
2000 |
|
15% discount offered to samples received from BIS. |
| 6.3(Protection of the telecommunication wiring system from overheating) |
- |
2000 |
|
15% discount offered to samples received from BIS. |
| 7.1(General) |
- |
0 |
|
Not Applicable. |
| 7.2(Protection of cable distribution system service persons, and users of other equipment connected to the system, from hazardous voltages in the equipment) |
- |
2000 |
|
15% discount offered to samples received from BIS. |
| 7.3(Protection of equipment users from overvoltages on the cable distribution system) |
- |
2000 |
|
15% discount offered to samples received from BIS. |
| 7.4(Insulation between primary circuits and cable distribution systems) |
- |
2000 |
|
15% discount offered to samples received from BIS. |
| 1.5(Components) |
- |
0 |
|
Not Applicable |
| 2.8(Safety interlocks) |
- |
0 |
|
Not Applicable. |
|
27 Apr, 2029 |
- - |
| 1283 |
COTERD SOLUTIONS (OPC) PRIVATE LIMITED, AC TEST LAB, GREATER NOIDA
| 8170806
| IS 17681 (2022) |
Specification for Bottled water dispensers |
All Types Mentioned in the Specification |
185000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4(Construction) |
- |
5000 |
|
- |
| 4.1(General Design) |
- |
500 |
|
- |
| 4.2(Materials) |
- |
500 |
|
- |
| 4.3(Finish) |
- |
500 |
|
- |
| 4.4(Thermal Insulation) |
- |
500 |
|
- |
| 4.5(Hardware) |
- |
500 |
|
- |
| 4.6(Disposal of Waste Water) |
- |
500 |
|
- |
| 4.7(Hot Water Tank) |
- |
500 |
|
- |
| 4.8(Hermetically Sealed Compressor) |
- |
500 |
|
- |
| 4.9(Protective Guards) |
- |
500 |
|
- |
| 5(Refrigeration System) |
- |
5000 |
|
- |
| 5.1(Pipes and Connections/Fitting) |
- |
500 |
|
- |
| 5.2(Control of Operation) |
- |
500 |
|
- |
| 6.1(General) |
- |
1000 |
|
- |
| 6.1(Protection against electric shock (Cl. 8 of IS 302-2-24)) |
- |
5000 |
|
- |
| 6.1(Power Input & Current (Cl. 10 of IS 302-2-24)) |
- |
5000 |
|
- |
| 6.1(Temperature Rise/ Heating (Cl. 11 of IS 302-2-24)) |
- |
5000 |
|
- |
| 6.1("Insulation Resistance and Electric Strength/ Leakage Current and Electric Strength
(Cl. 13 of IS 302-2-24)") |
- |
5000 |
|
- |
| 6.1("Moisture Resistance
(Cl. 15 of IS 302-2-24)") |
- |
5000 |
|
- |
| 6.1("Insulation resistance and electric strength
(After humidity treatment)
(Cl. 16 of IS 302-2-24)") |
- |
5000 |
|
- |
| 6.1("Provision For Earthing
(Cl. 27 of IS 302-2-24)") |
- |
5000 |
|
- |
| 6.1("Screws & Connections
(Cl. 28 of IS 302-2-24)") |
- |
5000 |
|
- |
| 6.2(Electrical Accessories) |
- |
500 |
|
- |
| 6.3(Salt Mist Test) |
- |
30000 |
|
- |
| 7(Sound pressure level) |
- |
15000 |
|
- |
| 10.1(Cooling Capacity Test) |
- |
30000 |
|
- |
| 10.2(Maximum Operating Condition Test (Environmental)) |
- |
20000 |
|
- |
| 10.3(Maximum Operating Condition Test (Voltage)) |
- |
20000 |
|
- |
| 10.4(Heating Capacity Test) |
- |
30000 |
|
- |
| 10.5(Annual Energy Consumption Test) |
- |
20000 |
|
- |
| 10.6(Freeze-up Test) |
- |
20000 |
|
- |
| 10.7(Door Opening and Closing Test) |
- |
5000 |
|
- |
| 10.8(Door Seal Test) |
- |
1000 |
|
- |
| 10.9(Pull-down Test) |
- |
1000 |
|
- |
| 11(Marking and instruction) |
- |
500 |
|
- |
|
15 Jul, 2028 |
- Included w.e.f. 29.01.2026 |
| 1284 |
Samridhi Test House Pvt. Ltd.
| 8184706
| IS 17550 : Part 3 (2025) |
Household Refrigerating Appliances - Characteristics and Methods Of Test Part 3 Energy Consumption and Volume (First Revision) |
- |
128000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Clause 4.1, Annex A(set up for energy consumption) |
- |
14500 |
|
- |
| Clause 4.2, Annex B(Steady state power consumption) |
- |
14500 |
|
- |
| Clause 4.3, Annex C(Defrost and Recovery Energy and Temperature Change) |
- |
14500 |
|
- |
| Clause 4.4, Annex D(Defrost Frequency) |
- |
14500 |
|
- |
| Clause 4.5, Annex E(Number of Test Points and Interpolation) |
- |
9500 |
|
- |
| Clause 4.6, Annex G(Load Processing Efficiency) |
- |
14500 |
|
- |
| Clause 4.7, Annex F(Specified Auxiliaries) |
- |
14500 |
|
- |
| Clause 4.8, Annex H(Volume determination) |
- |
7900 |
|
- |
| Clause 4.8.1, Annex H(Rated total volume) |
- |
7900 |
|
- |
| Clause 5, 5.1, 5.2 Table 1(TARGET TEMPERATURES FOR ENERGY DETERMINATION) |
- |
700 |
|
- |
| Clause 6, 6.1 to 6.8(DETERMINATION OF ENERGY CONSUMPTION) |
- |
25000 |
|
- |
|
- |
- Included w.e.f. 25.03.2026 |
| 1285 |
MORBI TEST HOUSE LLP
| 7195306
| IS 710 (2024) |
MARINE PLYWOOD - SPECIFICATION (Third Revision) |
All Grade / Type / Size / Designation |
15000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl-4.1(Timber) |
- |
100 |
|
- |
| Cl-4.2(Adhesive) |
- |
4000 |
|
- |
| Cl-5.1(Veneers) |
- |
100 |
|
- |
| Cl-5.2.1(Glueing) |
- |
100 |
|
- |
| Cl -5.2.2(Thickness of Veneers) |
- |
100 |
|
- |
| Cl - 5.2.3.1(Joint in Veneers) |
- |
100 |
|
- |
| Cl - 5.2.3.2(Edge joints) |
- |
100 |
|
- |
| Cl - 5.2.3.3(End joints) |
- |
100 |
|
- |
| Cl - 5.2.3.4(Scarf joints) |
- |
100 |
|
- |
| Cl - 5.2.4(Grain Direction) |
- |
100 |
|
- |
| Cl-5.3(Treatment) |
- |
0 |
|
- |
| Cl-5.4(Moisture Content) |
- |
100 |
|
- |
| Cl-6.1(Dimensions (length)) |
- |
200 |
|
- |
| Cl-6.2(Thickness) |
- |
200 |
|
- |
| Cl-6.3(Squareness) |
- |
500 |
|
- |
| Cl-7.1, 7.2, 7.3, 7.4, 7.5 & 7.6(Workmanship and finish) |
- |
200 |
|
- |
| Cl-9.3(Moisture Content) |
- |
100 |
|
- |
| Cl-9.4.2(Glue Adhesion in Dry State- Adhesion of Plies) |
- |
1000 |
|
- |
| Cl-9.4.1(Glue Adhesion in Dry State- Glue Shear Strength -Average) |
- |
1000 |
|
- |
| Cl-9.5.1.1(Glue Adhesion in Water Resistance - Glue Shear Strength -Average) |
- |
1000 |
|
- |
| Cl-9.5.1.2(Water Resistance Test-Adhesion of plies) |
- |
1000 |
|
- |
| Cl-9.5.2(Water Resistance Test) |
- |
2000 |
|
- |
| Cl-9.6(Tensile Strength-Along the grain) |
- |
1500 |
|
- |
| Cl-9.7(Mycological Test -Adhesion) |
- |
1500 |
|
- |
| Cl-9.8, Table-2(Static Bending Strength - Modulus of Elasticity - Along the Face Grain - Average) |
- |
1000 |
|
- |
| Cl-9.8, Table-2(Static Bending Strength - Modulus of Elasticity - Along the Face Grain - Minimum Individual) |
- |
1000 |
|
- |
| Cl-9.9, Table-3 (i) a((Modulus of Elasticity: Across the Face Grain: Average) Wet Bending) |
- |
1500 |
|
- |
| Cl-9.9, Table-3 (i) b((Modulus of Elasticity: Across the Face Grain: Minimum Individual) Wet Bending) |
- |
1500 |
|
- |
| Cl-9.10(Retention of Preservative) |
- |
1500 |
|
- |
| Cl-9.11(Formaldehyde Content Test) |
- |
2000 |
|
- |
| Cl-9.4.2(Adhesion of Plies) |
- |
100 |
|
- |
| 5.1.1(Defects in veneers) |
- |
100 |
|
- |
| Cl-9.8, Table-2(Static Bending Strength - Modulus of Elasticity - Across the Face Grain - Average) |
- |
1000 |
|
- |
| Cl-9.8, Table-2(Static Bending Strength - Modulus of Elasticity - Across the Face Grain - Minimum Individual) |
- |
1000 |
|
- |
| Cl-9.9, Table-3 (ii) a((Modulus of Rupture: Across the Face Grain: Average) Wet Bending) |
- |
1500 |
|
- |
| Cl-9.9, Table-3 (ii) b((Modulus of Rupture: Across the Face Grain: Minimum Individual) Wet Bending) |
- |
1500 |
|
- |
| Cl-6.1(Dimensions (width)) |
- |
200 |
|
- |
| Cl-8.3(Edge Straightness) |
- |
500 |
|
- |
| Cl-9.4.1(Glue Adhesion in Dry State- Glue Shear Strength –Minimum Individual) |
- |
1000 |
|
- |
| Cl-9.5.1.1(Glue Adhesion in Water Resistance - Glue Shear Strength –Minimum Individual) |
- |
1000 |
|
- |
| Cl-9.6(Tensile Strength-Across the grain) |
- |
1500 |
|
- |
| Cl-9.7(Glue Adhesion in Mycological test - Glue Shear Strength –Minimum Individual) |
- |
1500 |
|
- |
| Cl-9.7(Glue Adhesion in Mycological test - Glue Shear Strength -Average) |
- |
1500 |
|
- |
| Cl-9.8, Table-2(Static Bending Strength - Modulus of Rupture - Along the Face Grain - Average) |
- |
1000 |
|
- |
| Cl-9.8, Table-2(Static Bending Strength - Modulus of Rupture - Along the Face Grain - Minimum Individual) |
- |
1000 |
|
- |
| Cl-9.8, Table-2(Static Bending Strength - Modulus of Rupture - Across the Face Grain - Minimum Individual) |
- |
1000 |
|
- |
| Cl-9.8, Table-2(Static Bending Strength - Modulus of Rupture - Across the Face Grain - Average) |
- |
1000 |
|
- |
| Cl-11.1(Marking) |
- |
0 |
|
- |
| Cl-11.3(Marking) |
- |
0 |
|
- |
| Cl-4.1(Timber) |
- |
100 |
|
- |
| Cl-4.2(Adhesive) |
- |
4000 |
|
- |
| Cl-5.1(Veneers) |
- |
100 |
|
- |
| Cl-5.2.1(Glueing) |
- |
100 |
|
- |
| Cl -5.2.2(Thickness of Veneers) |
- |
100 |
|
- |
| Cl - 5.2.3.1(Joint in Veneers) |
- |
100 |
|
- |
| Cl - 5.2.3.2(Edge joints) |
- |
100 |
|
- |
| Cl - 5.2.3.3(End joints) |
- |
100 |
|
- |
| Cl - 5.2.3.4(Scarf joints) |
- |
100 |
|
- |
| Cl - 5.2.4(Grain Direction) |
- |
100 |
|
- |
| Cl-5.3(Treatment) |
- |
0 |
|
- |
| Cl-5.4(Moisture Content) |
- |
100 |
|
- |
| Cl-6.1(Dimensions (length)) |
- |
200 |
|
- |
| Cl-6.2(Thickness) |
- |
200 |
|
- |
| Cl-6.3(Squareness) |
- |
500 |
|
- |
| Cl-7.1, 7.2, 7.3, 7.4, 7.5 & 7.6(Workmanship and finish) |
- |
200 |
|
- |
| Cl-9.3(Moisture Content) |
- |
200 |
|
- |
| Cl-9.4.2(Glue Adhesion in Dry State- Adhesion of Plies) |
- |
1000 |
|
- |
| Cl-9.4.1(Glue Adhesion in Dry State- Glue Shear Strength -Average) |
- |
1000 |
|
- |
| Cl-9.5.1.1(Glue Adhesion in Water Resistance - Glue Shear Strength -Average) |
- |
1000 |
|
- |
| Cl-9.5.1.2(Water Resistance Test-Adhesion of plies) |
- |
1000 |
|
- |
| Cl-9.5.2(Water Resistance Test) |
- |
2000 |
|
- |
| Cl-9.6(Tensile Strength-Along the grain) |
- |
1500 |
|
- |
| Cl-9.7(Mycological Test -Adhesion) |
- |
1500 |
|
- |
| Cl-9.8, Table-2(Static Bending Strength - Modulus of Elasticity - Along the Face Grain - Average) |
- |
1000 |
|
- |
| Cl-9.8, Table-2(Static Bending Strength - Modulus of Elasticity - Along the Face Grain - Minimum Individual) |
- |
1000 |
|
- |
| Cl-9.9, Table-3 (i) a((Modulus of Elasticity: Across the Face Grain: Average) Wet Bending) |
- |
1500 |
|
- |
| Cl-9.9, Table-3 (i) b((Modulus of Elasticity: Across the Face Grain: Minimum Individual) Wet Bending) |
- |
1500 |
|
- |
| Cl-9.10(Retention of Preservative) |
- |
1500 |
|
- |
| Cl-9.11(Formaldehyde Content Test) |
- |
2000 |
|
- |
| Cl-9.4.2(Adhesion of Plies) |
- |
100 |
|
- |
| 5.1.1(Defects in veneers) |
- |
100 |
|
- |
| Cl-9.8, Table-2(Static Bending Strength - Modulus of Elasticity - Across the Face Grain - Average) |
- |
1000 |
|
- |
| Cl-9.8, Table-2(Static Bending Strength - Modulus of Elasticity - Across the Face Grain - Minimum Individual) |
- |
1000 |
|
- |
| Cl-9.9, Table-3 (ii) a((Modulus of Rupture: Across the Face Grain: Average) Wet Bending) |
- |
1500 |
|
- |
| Cl-9.9, Table-3 (ii) b((Modulus of Rupture: Across the Face Grain: Minimum Individual) Wet Bending) |
- |
1500 |
|
- |
| Cl-6.1(Dimensions (width)) |
- |
200 |
|
- |
| Cl-8.3(Edge Straightness) |
- |
500 |
|
- |
| Cl-9.4.1(Glue Adhesion in Dry State- Glue Shear Strength –Minimum Individual) |
- |
1000 |
|
- |
| Cl-9.5.1.1(Glue Adhesion in Water Resistance - Glue Shear Strength –Minimum Individual) |
- |
1000 |
|
- |
| Cl-9.6(Tensile Strength-Across the grain) |
- |
1500 |
|
- |
| Cl-9.7(Glue Adhesion in Mycological test - Glue Shear Strength –Minimum Individual) |
- |
1500 |
|
- |
| Cl-9.7(Glue Adhesion in Mycological test - Glue Shear Strength -Average) |
- |
1500 |
|
- |
| Cl-9.8, Table-2(Static Bending Strength - Modulus of Rupture - Along the Face Grain - Average) |
- |
1000 |
|
- |
| Cl-9.8, Table-2(Static Bending Strength - Modulus of Rupture - Along the Face Grain - Minimum Individual) |
- |
1000 |
|
- |
| Cl-9.8, Table-2(Static Bending Strength - Modulus of Rupture - Across the Face Grain - Minimum Individual) |
- |
1000 |
|
- |
| Cl-9.8, Table-2(Static Bending Strength - Modulus of Rupture - Across the Face Grain - Average) |
- |
1000 |
|
- |
| Cl-11.1(Marking) |
- |
0 |
|
- |
| Cl-11.3(Marking) |
- |
0 |
|
- |
|
- |
- Included w.e.f. 29.01.2026
Exclusion; Cl-9.12 (Steady-State Formaldehyde Emission Test) |
| 1286 |
JBS TESTING SOLUTIONS PVT LTD (27), JALANDHAR
| 9164606
| IS 204 : Part 2 (1992) |
Tower bolts - Specification: Part 2 non - Ferrous metals (Fifth Revision) |
- |
19800 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4 -Table 3- i (Ref. Cl 8, Table 1 Designation 63400 of IS 1285 : 2002)(Chemical composition - Aluminium - IS 504) |
- |
10300 |
|
For complete chemical test |
| 4 -Table 3- i (Ref. Cl 8 , Table 1 Designation 63400 of IS 1285 : 2002)(Chemical composition - Copper - IS 504) |
- |
10300 |
|
For complete chemical test |
| 4 -Table 3- i (Ref. Cl 8, Table 1 Designation 63400 of IS 1285 : 2002)(Chemical composition - Magnesium - IS 504) |
- |
10300 |
|
For complete chemical test |
| 4 -Table 3- i (Ref. Cl 8, Table 1 Designation 63400 of IS 1285 : 2002)(Chemical composition - Silicon - IS 504) |
- |
10300 |
|
For complete chemical test |
| 4 -Table 3- i (Ref. Cl 8 , Table 1 Designation 63400 of IS 1285 : 2002)(Chemical composition - Iron - IS 504) |
- |
10300 |
|
For complete chemical test |
| 4 -Table 3- i (Ref. Cl 8, Table 1 Designation 63400 of IS 1285 : 2002)(Chemical composition - Manganese - IS 504) |
- |
10300 |
|
For complete chemical test |
| 4 -Table 3- i (Ref. Cl 8, Table 1 Designation 63400 of IS 1285 : 2002)(Chemical composition - Zinc - IS 504) |
- |
10300 |
|
For complete chemical test |
| 4 -Table 3- i (Ref. Cl 8 , Table 1 Designation 63400 of IS 1285 : 2002)(Chemical composition - Titanium - IS 504) |
- |
10300 |
|
For complete chemical test |
| 4 -Table 3- i (Ref. Cl 8, Table 1 Designation 63400 of IS 1285 : 2002)(Chemical composition - Chromium - IS 504) |
- |
10299.98 |
|
For complete chemical test |
| 4 -Table 3- i (Ref. Cl 8, Table 1 Designation 63400 of IS 1285 : 2002)(Chemical composition - others - IS 504) |
- |
10300 |
|
For complete chemical test |
| 4 -Table 3- ii (Ref. Cl 5.1, Table 1 Designation 65032 of IS 733 : 1983)(Chemical composition - Aluminium - IS 504) |
- |
10300 |
|
For complete chemical test |
| 4 -Table 3- ii (Ref. Cl 5.1 , Table 1 Designation 65032 of IS 733 : 1983)(Chemical composition - Copper - IS 504) |
- |
10300 |
|
For complete chemical test |
| 4 -Table 3- ii (Ref. Cl 5.1 , Table 1 Designation 65032 of IS 733 : 1983)(Chemical composition - Magnesium - IS 504) |
- |
10300 |
|
For complete chemical test |
| 4 -Table 3- ii (Ref. Cl 5.1, Table 1 Designation 65032 of IS 733 : 1983)(Chemical composition - Silicon - IS 504) |
- |
10300 |
|
For complete chemical test |
| 4 -Table 3- ii (Ref. Cl 5.1 , Table 1 Designation 65032 of IS 733 : 1983)(Chemical composition - Iron - IS 504) |
- |
10300 |
|
For complete chemical test |
| 4 -Table 3- ii (Ref. Cl 5.1 , Table 1 Designation 65032 of IS 733 : 1983)(Chemical composition - Manganese - IS 504) |
- |
10300 |
|
For complete chemical test |
| 4 -Table 3- ii (Ref. Cl 5.1 , Table 1 Designation 65032 of IS 733 : 1983)(Chemical composition - Zinc - IS 504) |
- |
10300 |
|
For complete chemical test |
| 4 -Table 3- ii (Ref. Cl 5.1 , Table 1 Designation 65032 of IS 733 : 1983)(Chemical composition - Titanium and or other grain refining elements - IS 504) |
- |
10300 |
|
For complete chemical test |
| 4 -Table 3- ii (Ref. Cl 5.1, Table 1 Designation 65032 of IS 733 : 1983)(Chemical composition - Chromium - IS 504) |
- |
10300 |
|
For complete chemical test |
| 4 -Table 3- iii (Ref. Cl 6.1 , Table 1 Designation CuZn40 of IS 410 : 1977)(Chemical composition - Copper - IS 3635:1966) |
- |
10300 |
|
For complete chemical test |
| 4 -Table 3- iii (Ref. Cl 6.1 , Table 1 Designation CuZn40 of IS 410 : 1977)(Chemical composition - Lead - IS 3635:1966) |
- |
10300 |
|
For complete chemical test |
| 4 -Table 3- iii (Ref. Cl 6.1, Table 1 Designation CuZn40 of IS 410 : 1977)(Chemical composition - Iron - IS 3635:1966) |
- |
10300 |
|
For complete chemical test |
| 4 -Table 3- iii (Ref. Cl 6.1, Table 1 Designation CuZn40 of IS 410 : 1977)(Chemical composition - Total impurities (including Iron) - IS 3635:1966) |
- |
10300 |
|
For complete chemical test |
| 4 -Table 3- iii (Ref. Cl 6.1, Table 1 Designation CuZn40 of IS 410 : 1977)(Chemical composition - Zinc - IS 3635:1966) |
- |
10300 |
|
For complete chemical test |
| 4 -Table 3- iv (Ref. Cl 3.1, Table 1 Grade CB-2 of IS 292 : 1983)(Chemical composition - Copper plus incidental nickel - IS 3685:1966) |
- |
10300 |
|
For complete chemical test |
| 4 -Table 3- iv (Ref. Cl 3.1, Table 1 Grade CB-2 of IS 292 : 1983)(Chemical composition - Nickel - IS 3685:1966) |
- |
10300 |
|
For complete chemical test |
| 4 -Table 3- iv (Ref. Cl 3.1, Table 1 Grade CB-2 of IS 292 : 1983)(Chemical composition - Tin - IS 3685:1966) |
- |
10300 |
|
For complete chemical test |
| 4 -Table 3- iv (Ref. Cl 3.1, Table 1 Grade CB-2 of IS 292 : 1983)(Chemical composition - Iron - IS 3685:1966) |
- |
10300 |
|
For complete chemical test |
| 4 -Table 3- iv (Ref. Cl 3.1, Table 1 Grade CB-2 of IS 292 : 1983)(Chemical composition - Aluminium - IS 3685:1966) |
- |
10300 |
|
For complete chemical test |
| 4 -Table 3- iv (Ref. Cl 3.1, Table 1 Grade CB-2 of IS 292 : 1983)(Chemical composition - Zinc - IS 3685:1966) |
- |
10300 |
|
For complete chemical test |
| 4 -Table 3- v (Ref. Cl 8.1, Table 1 Grade II of IS 319 : 1974)(Chemical composition - Copper - IS 3685:1966) |
- |
10300 |
|
For complete chemical test |
| 4 -Table 3- v (Ref. Cl 8.1, Table 1 Grade II of IS 319 : 1974)(Chemical composition - Lead - IS 3685:1966) |
- |
10300 |
|
For complete chemical test |
| 4 -Table 3- v (Ref. Cl 8.1, Table 1 Grade II of IS 319 : 1974)(Chemical composition - Iron - IS 3685:1966) |
- |
10300 |
|
For complete chemical test |
| 4 -Table 3- v (Ref. Cl 8.1, Table 1 Grade II of IS 319 : 1974)(Chemical composition - Total other impurities excluding iron - IS 3685:1966) |
- |
10300 |
|
For complete chemical test |
| 4 -Table 3- v (Ref. Cl 8.1, Table 1 Grade II of IS 319 : 1974)(Chemical composition - Zinc- IS 3685:1966) |
- |
10300 |
|
For complete chemical test |
| 4 -Table 3- vi (Ref. Cl 4.1, Table 1 Alloy ZnAl4 of IS 742 : 1981)(Chemical composition - Aluminium- IS 2600:1964) |
- |
10300 |
|
For complete chemical test |
| 4 -Table 3- vi (Ref. Cl 4.1, Table 1 Alloy ZnAl4 of IS 742 : 1981)(Chemical composition - Magnesium- IS 2600:1964) |
- |
10300 |
|
For complete chemical test |
| 4 -Table 3- vi (Ref. Cl 4.1, Table 1 Alloy ZnAl4 of IS 742 : 1981)(Chemical composition - Impurities-Copper- IS 2600:1964) |
- |
10300 |
|
For complete chemical test |
| 4 -Table 3- vi (Ref. Cl 4.1, Table 1 Alloy ZnAl4 of IS 742 : 1981)(Chemical composition - Impurities-Iron- IS 2600:1964) |
- |
10300 |
|
For complete chemical test |
| 4 -Table 3- vi (Ref. Cl 4.1, Table 1 Alloy ZnAl4 of IS 742 : 1981)(Chemical composition - Impurities-Lead- IS 2600:1964) |
- |
10300 |
|
For complete chemical test |
| 4 -Table 3- vi (Ref. Cl 4.1, Table 1 Alloy ZnAl4 of IS 742 : 1981)(Chemical composition - Impurities-Cadmium- IS 2600:1964) |
- |
10300 |
|
For complete chemical test |
| 4 -Table 3- vi (Ref. Cl 4.1, Table 1 Alloy ZnAl4 of IS 742 : 1981)(Chemical composition - Impurities-Tin- IS 2600:1964) |
- |
10300 |
|
For complete chemical test |
| 4 -Table 3- vi (Ref. Cl 4.1, Table 1 Alloy ZnAl4 of IS 742 : 1981)(Chemical composition - Impurities-Thallium and Indium- IS 2600:1964) |
- |
10300 |
|
For complete chemical test |
| 4 -Table 3- vi (Ref. Cl 4.1, Table 1 Alloy ZnAl4 of IS 742 : 1981)(Chemical composition - Impurities-Nickel- IS 2600:1964) |
- |
10300 |
|
For complete chemical test |
| 4 -Table 3- vi (Ref. Cl 4.1, Table 1 Alloy ZnAl4 of IS 742 : 1981)(Chemical composition - Zinc- IS 2600:1964) |
- |
10300 |
|
For complete chemical test |
| 5.1(General) |
- |
9500 |
|
For complete dimensional and other qualitative tests |
| 5.2.1 Table 1(Particulars-Barrel Tower Bolts) |
- |
9500 |
|
For complete dimensional and other qualitative tests |
| 5.2.2 Table 2(Particulars-Skeleton Tower Bolts) |
- |
9500 |
|
For complete dimensional and other qualitative tests |
| 6.1- Table 1(Dimension of Barrel tower bolts-1.Size 2.Length of Bolt or Barrel-(A or B) 4.Width of Barrel-C 5.Dia of Bolt-D 6.Length of Socket-E 7.Thickness of Metal of Barrel (Brass or Zink Alloy/Aluminium alloy/Sheet Brass)-F 8.Dia of bore of barrel or socket- G ) |
- |
9500 |
|
For complete dimensional and other qualitative tests |
| 6.1- Table 1(Dimension of barrel tower bolts-Minimum No. of equally Spaced holes in Barrel & Socket for wooden screw no 6) |
- |
9500 |
|
For complete dimensional and other qualitative tests |
| 6.2- Table 2(Dimension of Skeleton Tower Bolts 1.Size 2.Length of Bolt -A 3.Length of Bolt Plate -B 4.Width of Bolt Plate or Staple-C 5.Dia of Bolt-D 6.Length of Staple-E 7.Thickness of Plate or Socket (Brass /Aluminium alloy or Zink Alloy)-F 8.Dia of bore of Plate or Staple-G 9.Dia of shank of Knob ) |
- |
9500 |
|
For complete dimensional and other qualitative tests |
| 6.2- Table 2(Dimension of Skeleton Tower Bolts- Nos of Staples) |
- |
9500 |
|
For complete dimensional and other qualitative tests |
| 6.2- Table 2(Dimension of Skeleton Tower Bolts-Minimum No. of Screw holes for wood screw no 4) |
- |
9500 |
|
For complete dimensional and other qualitative tests |
| 6.2- Table 3(PACKING) |
- |
9500 |
|
For complete dimensional and other qualitative tests |
| 7(Finish) |
- |
9500 |
|
For complete dimensional and other qualitative tests |
| 8(Packing) |
- |
9500 |
|
For complete dimensional and other qualitative tests |
| 9(Scale of sampling) |
- |
9500 |
|
For complete dimensional and other qualitative tests |
| 10(Marking) |
- |
9500 |
|
For complete dimensional and other qualitative tests |
|
- |
- Included w.e.f 22.01.2026 |
| 1287 |
Unique Test House LLP
| 9134536
| IS 1783 : Part 2 (2014) |
Drums large, fixed ends - Specification: Part 2 grade B drums (Fourth Revision) |
ALL SIZES |
15000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4(Capacity) |
- |
100 |
|
......... |
| 5(Dimensions (Type 1 C Drums Figure 1)) |
- |
200 |
|
.......... |
| 5(Dimensions (Type 1 C Drums Figure 1)) |
- |
200 |
|
....................... |
| 5(Dimensions (Type 1 C Drums Figure 1)) |
- |
200 |
|
............................. |
| 5(Dimensions (Type 1 C Drums Figure 1)) |
- |
200 |
|
....................... |
| 5(Dimensions (Type 1 C Drums Figure 1)) |
- |
200 |
|
........................ |
| 5(Dimensions (Type 1 C Drums Figure 1)) |
- |
200 |
|
............................ |
| 5(Dimensions (Type 1 C Drums Figure 1)) |
- |
200 |
|
........................ |
| 5(Dimensions (Type 1 C Drums Figure 1)) |
- |
200 |
|
....................... |
| 5(Dimensions (Type 1 D Drums Figure 1)) |
- |
200 |
|
............................... |
| 5(Dimensions (Type 1 D Drums Figure 1)) |
- |
200 |
|
.......................... |
| 5(Dimensions (Type 1 D Drums Figure 1)) |
- |
200 |
|
........................ |
| 5(Dimensions (Type 1 D Drums Figure 1)) |
- |
200 |
|
.......................... |
| 5(Dimensions (Type 1 D Drums Figure 1)) |
- |
200 |
|
...................... |
| 5(Dimensions (Type 1 D Drums Figure 1)) |
- |
200 |
|
............................. |
| 5(Dimensions (Type 1 D Drums Figure 1)) |
- |
200 |
|
.......................... |
| 5(Dimensions (Type 1 D Drums Figure 1)) |
- |
200 |
|
........................ |
| 5(Dimensions (Type 1 C Drums Figure 2)) |
- |
200 |
|
............................... |
| 5(Dimensions (Type 1 C Drums Figure 2)) |
- |
200 |
|
.............................. |
| 5(Dimensions (Type 1 C Drums Figure 2)) |
- |
200 |
|
............................ |
| 5(Dimensions (Type 1 C Drums Figure 2)) |
- |
200 |
|
........................... |
| 5(Dimensions (Type 1 C Drums Figure 2)) |
- |
200 |
|
........................... |
| 5(Dimensions (Type 1 C Drums Figure 2)) |
- |
200 |
|
.......................... |
| 5(Dimensions (Type 1 C Drums Figure 2)) |
- |
200 |
|
............................ |
| 5(Dimensions (Type 1 C Drums Figure 2)) |
- |
200 |
|
................................... |
| 5(Dimensions (Type 1 D Drums Figure 2)) |
- |
200 |
|
................................ |
| 5(Dimensions (Type 1 D Drums Figure 2)) |
- |
200 |
|
............. |
| 5(Dimensions (Type 1 D Drums Figure 2)) |
- |
200 |
|
....... |
| 5(Dimensions (Type 1 D Drums Figure 2)) |
- |
200 |
|
..... |
| 5(Dimensions (Type 1 D Drums Figure 2)) |
- |
200 |
|
..... |
| 5(Dimensions (Type 1 D Drums Figure 2)) |
- |
200 |
|
...... |
| 5(Dimensions (Type 1 D Drums Figure 2)) |
- |
200 |
|
....... |
| 5(Dimensions (Type 1 D Drums Figure 2)) |
- |
200 |
|
....... |
| 6(Material) |
- |
500 |
|
..... |
| 7(Construction) |
- |
300 |
|
........ |
| 7.1(Construction) |
- |
300 |
|
........ |
| 7.2(Construction) |
- |
300 |
|
......... |
| 7.3(Construction) |
- |
300 |
|
.................. |
| 7.4(Construction) |
- |
300 |
|
................... |
| 7.5(Construction) |
- |
300 |
|
......... |
| 7.7(Construction) |
- |
300 |
|
.................................. |
| 8(Finish ) |
- |
100 |
|
........................ |
| 9.1(Leakage at air pressure ) |
- |
500 |
|
................ |
| 9.2(Drop Test) |
- |
500 |
|
......... |
| 9.3(Hydraulic Pressure Test) |
- |
500 |
|
........ |
| 5(Dimensions (Type 2 C Drums Figure 2)) |
- |
150 |
|
............................ |
| 5(Dimensions (Type 2 C Drums Figure 2)) |
- |
150 |
|
............................. |
| 5(Dimensions (Type 2 C Drums Figure 2)) |
- |
150 |
|
...... |
| 5(Dimensions (Type 2 C Drums Figure 2)) |
- |
150 |
|
.......................... |
| 5(Dimensions (Type 2 C Drums Figure 2)) |
- |
150 |
|
............ |
| 5(Dimensions (Type 2 C Drums Figure 2)) |
- |
150 |
|
........................... |
| 5(Dimensions (Type 2 C Drums Figure 2)) |
- |
150 |
|
.............................. |
| 5(Dimensions (Type 2 C Drums Figure 2)) |
- |
150 |
|
......................... |
| 5(Dimensions (Type 2 C Drums Figure 2)) |
- |
150 |
|
........................ |
| 5(Dimensions (Type 2 C Drums Figure 2)) |
- |
150 |
|
............................... |
| 5(Dimensions (Type 2 D Drums Figure 2)) |
- |
150 |
|
........................... |
| 5(Dimensions (Type 2 D Drums Figure 2)) |
- |
150 |
|
.................................... |
| 5(Dimensions (Type 2 D Drums Figure 2)) |
- |
150 |
|
............................... |
| 5(Dimensions (Type 2 D Drums Figure 2)) |
- |
150 |
|
.................................. |
| 5(Dimensions (Type 2 D Drums Figure 2)) |
- |
150 |
|
........................................... |
| 5(Dimensions (Type 2 D Drums Figure 2)) |
- |
150 |
|
............................ |
| 5(Dimensions (Type 2 D Drums Figure 2)) |
- |
150 |
|
........................... |
| 5(Dimensions (Type 2 D Drums Figure 2)) |
- |
150 |
|
........................... |
| 5(Dimensions (Type 2 D Drums Figure 2)) |
- |
150 |
|
................................. |
| 5(Dimensions (Type 2 D Drums Figure 2)) |
- |
150 |
|
.......................... |
| 5(Dimensions (Type 2 D Drums Figure 2)) |
- |
150 |
|
....................... |
| 6(Material) |
- |
100 |
|
.......................... |
| 6(Material) |
- |
100 |
|
................ |
|
07 Sep, 2028 |
- Included w.e.f 22.01.2026 |
| 1288 |
Bengaluru Smart Laboratory, Indian Oil Corporation Limited (IOCL)
| 6193214
| IS 1571 (2018) |
Aviation turbine fuels, kerosine type, jet - A - 1 - Specification (Tenth Revision) |
- |
39790 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl-3.2.2, 3.2.6, Table-1 (a)(Visual appearance) |
- |
200 |
|
- |
| Cl-3.2.2, 3.2.6, Table-1 (B)(Colour) |
- |
1130 |
|
- |
| Cl-3.2.2, 3.2.6, Table-1, (iii) (a), 1)(Distillation:- Initial boiling point, °) |
- |
2650 |
|
- |
| Cl-3.2.2, 3.2.6, Table-1, (ii) (a)(Total acidi,t y mg KOHM/ga, x) |
- |
1530 |
|
- |
| Cl-3.2.2, 3.2.6, Table-1, (ii) (b)("Aromatics, percent by volMumaex,
or
Total Aromatics, percent by volume, Max") |
- |
2650 |
|
- |
| Cl-3.2.2, 3.2.6, Table-1, (ii) (c)(Total sulphur percent by mass, Max) |
- |
2650 |
|
- |
| Cl-3.2.2, 3.2.6, Table-1, (ii) (d)(Sulphur mercaptan, percent m/m. Max) |
- |
1900 |
|
- |
| Cl-3.2.2, 3.2.6, Table-1, (iii) (a), 2)(Distillation:- 10 percent recovery °Cv/,v , Max) |
- |
2650 |
|
- |
| Cl-3.2.2, 3.2.6, Table-1, (iii) (a), 3)(Distillation:- 50 percent recovery °C, v/v) |
- |
2650 |
|
- |
| Cl-3.2.2, 3.2.6, Table-1, (iii) (a), 3)(Distillation:- 50 percent recovery °C, v/v) |
- |
2650 |
|
- |
| Cl-3.2.2, 3.2.6, Table-1, (iii) (a), 4)(Distillation:- 90 percent recovery °C, v/v) |
- |
2650 |
|
- |
| Cl-3.2.2, 3.2.6, Table- 1, (iii) (a), 5)(Distillation:- Final boiling point,°C, Max) |
- |
2650 |
|
- |
| Cl-3.2.2, 3.2.6, Table-1, (iii) (a), 6)(Distillation:- Residue, percent v/v, Max) |
- |
2650 |
|
- |
| Cl-3.2.2, 3.2.6, Table-1, (iii) (a), 7)(Distillation:- Loss, percent v/v, Max) |
- |
2650 |
|
- |
| Cl-3.2.2, 3.2.6, Table-1, (iii) (b)(Flash point ( Abel ), °C, Min) |
- |
1900 |
|
- |
| Cl-3.2.2, 3.2.6, Table-1, (iii) (c)(Density at 15°C,kg/m3) |
- |
1130 |
|
- |
| Cl-3.2.2, 3.2.6, Table- 1, (iv) (a)(Fluidity:- Freezing point, °C, Max) |
- |
2270 |
|
- |
| Cl-3.2.2, 3.2.6, Table-1, (iv) (b)(Fluidity:- Kinematic viscosity at minus 20°C, mm2/s, Max) |
- |
2270 |
|
- |
| Cl-3.2.2, 3.2.6, Table-1, (v) (a)(Specific energy10) MJ/kg, Min) |
- |
2480 |
|
- |
| Cl-3.2.2, 3.2.6, Table-1, (v) (b)(Smoke point, mm, Min or) |
- |
1130 |
|
- |
| Cl-3.2.2, 3.2.6, Table-1, (v) (b) 2)(Naphthalenes, percent v/v, Max) |
- |
2650 |
|
- |
| Cl-3.2.2, 3.2.6, Table-1, (vi) (a)(Copper strip corrosion for 2 h at 100°C) |
- |
1130 |
|
- |
| Cl-3.2.2, 3.2.6, Table-1, (vi) (b)("Silver stripcorrosion12)
classification, for 4 h at 50°C, Max") |
- |
1340 |
|
- |
| Cl-3.2.2, 3.2.6, Table-1, (viii)(Contaminants: Existent gum, mg/100 ml, Max) |
- |
2070 |
|
- |
| Cl-3.2.2, 3.2.6, Table-1, (ix) a)(Water reaction: Interface rating16), Max) |
- |
780 |
|
- |
| Cl-3.2.2, 3.2.6, Table-1, (x)(Conductivity: Electrical conductivity, pS/m19)) |
- |
1340 |
|
- |
| Amendment No.5 Table 3 Clause G-2.5 ii(Fluidity-Freezing point) |
- |
2270 |
|
- |
| Amendment No.5 Table 3 Clause G-2.5 iii(Aromatics) |
- |
3650 |
|
- |
| Cl-3.2.2, 3.2.6, Table-1, (ii) (b)(Aromatics, percent by vol (Defense requirements)) |
- |
2650 |
|
- |
| Cl-3.2.2, 3.2.6, Table-1, (ii) (c)(Total sulphur percent by mass, Max (Defense requirements)) |
- |
2650 |
|
- |
| Cl-3.2.2, 3.2.6, Table-1, (ii) (d)(Sulphur mercaptan, percent m/m. (Defense requirements)) |
- |
1900 |
|
- |
| Cl-3.2.2, 3.2.6, Table-1, (vi) (b)(Silver stripcorrosion12) classification, for 4 h at 50°C, (Defense requirements)) |
- |
1340 |
|
- |
| Cl-3.2.2, 3.2.6, Table-1 (a)(Visual appearance) |
- |
200 |
|
- |
| Cl-3.2.2, 3.2.6, Table-1 (B)(Colour) |
- |
1130 |
|
- |
| Cl-3.2.2, 3.2.6, Table-1, (iii) (a), 1)(Distillation:- Initial boiling point, °) |
- |
2650 |
|
- |
| Cl-3.2.2, 3.2.6, Table-1, (ii) (a)(Total acidi,t y mg KOHM/ga, x) |
- |
1530 |
|
- |
| Cl-3.2.2, 3.2.6, Table-1, (ii) (b)("Aromatics, percent by volMumaex,
or
Total Aromatics, percent by volume, Max") |
- |
2650 |
|
- |
| Cl-3.2.2, 3.2.6, Table-1, (ii) (c)(Total sulphur percent by mass, Max) |
- |
2650 |
|
- |
| Cl-3.2.2, 3.2.6, Table-1, (ii) (d)(Sulphur mercaptan, percent m/m. Max) |
- |
1900 |
|
- |
| Cl-3.2.2, 3.2.6, Table-1, (iii) (a), 2)(Distillation:- 10 percent recovery °Cv/,v , Max) |
- |
2650 |
|
- |
| Cl-3.2.2, 3.2.6, Table-1, (iii) (a), 3)(Distillation:- 50 percent recovery °C, v/v) |
- |
2650 |
|
- |
| Cl-3.2.2, 3.2.6, Table-1, (iii) (a), 3)(Distillation:- 50 percent recovery °C, v/v) |
- |
2650 |
|
- |
| Cl-3.2.2, 3.2.6, Table-1, (iii) (a), 4)(Distillation:- 90 percent recovery °C, v/v) |
- |
2650 |
|
- |
| Cl-3.2.2, 3.2.6, Table- 1, (iii) (a), 5)(Distillation:- Final boiling point,°C, Max) |
- |
2650 |
|
- |
| Cl-3.2.2, 3.2.6, Table-1, (iii) (a), 6)(Distillation:- Residue, percent v/v, Max) |
- |
2650 |
|
- |
| Cl-3.2.2, 3.2.6, Table-1, (iii) (a), 7)(Distillation:- Loss, percent v/v, Max) |
- |
2650 |
|
- |
| Cl-3.2.2, 3.2.6, Table-1, (iii) (b)(Flash point ( Abel ), °C, Min) |
- |
1900 |
|
- |
| Cl-3.2.2, 3.2.6, Table-1, (iii) (c)(Density at 15°C,kg/m3) |
- |
1130 |
|
- |
| Cl-3.2.2, 3.2.6, Table- 1, (iv) (a)(Fluidity:- Freezing point, °C, Max) |
- |
2270 |
|
- |
| Cl-3.2.2, 3.2.6, Table-1, (iv) (b)(Fluidity:- Kinematic viscosity at minus 20°C, mm2/s, Max) |
- |
2270 |
|
- |
| Cl-3.2.2, 3.2.6, Table-1, (v) (a)(Specific energy10) MJ/kg, Min) |
- |
2480 |
|
- |
| Cl-3.2.2, 3.2.6, Table-1, (v) (b)(Smoke point, mm, Min or) |
- |
1130 |
|
- |
| Cl-3.2.2, 3.2.6, Table-1, (v) (b) 2)(Naphthalenes, percent v/v, Max) |
- |
2650 |
|
- |
| Cl-3.2.2, 3.2.6, Table-1, (vi) (a)(Copper strip corrosion for 2 h at 100°C) |
- |
1130 |
|
- |
| Cl-3.2.2, 3.2.6, Table-1, (vi) (b)("Silver stripcorrosion12)
classification, for 4 h at 50°C, Max") |
- |
1340 |
|
- |
| Cl-3.2.2, 3.2.6, Table-1, (viii)(Contaminants: Existent gum, mg/100 ml, Max) |
- |
2070 |
|
- |
| Cl-3.2.2, 3.2.6, Table-1, (ix) a)(Water reaction: Interface rating16), Max) |
- |
780 |
|
- |
| Cl-3.2.2, 3.2.6, Table-1, (x)(Conductivity: Electrical conductivity, pS/m19)) |
- |
1340 |
|
- |
| Amendment No.5 Table 3 Clause G-2.5 ii(Fluidity-Freezing point) |
- |
2270 |
|
- |
| Amendment No.5 Table 3 Clause G-2.5 iii(Aromatics) |
- |
3650 |
|
- |
| Cl-3.2.2, 3.2.6, Table-1, (ii) (b)(Aromatics, percent by vol (Defense requirements)) |
- |
2650 |
|
- |
| Cl-3.2.2, 3.2.6, Table-1, (ii) (c)(Total sulphur percent by mass, Max (Defense requirements)) |
- |
2650 |
|
- |
| Cl-3.2.2, 3.2.6, Table-1, (ii) (d)(Sulphur mercaptan, percent m/m. (Defense requirements)) |
- |
1900 |
|
- |
| Cl-3.2.2, 3.2.6, Table-1, (vi) (b)(Silver stripcorrosion12) classification, for 4 h at 50°C, (Defense requirements)) |
- |
1340 |
|
- |
|
10 Dec, 2028 |
- Excluding: Cl-3.1 (General-Material) Cl-3.2 (Composition) Cl-3.2.1 (Antioxidants) Cl-3.2.2 (Metal Deactivator Additive (MDA)) Cl-3.2.3 (Static Dissipater Additive (SDA)) Cl-3.2.4 (Lubricity Improver Additive (LIA)) Cl-3.2.5 (Fuel System Icing Inhibitor (FSII)) Cl-3.2.7 (Leak Detection Additive) Cl-5.2 (Marking) Cl-3.2.2, 3.2.6, Table-1 (c) (Particulate contamination, at point of 1.02) manufacture, mg/l, Max) Cl-3.2.2, 3.2.6, Table-1 (d) 1) (Particulate, at point of manufacture, cumulative channel particle counts:- ≥ 4 μm©) Cl-3.2.2, 3.2.6, Table-1 (d) 2) (Particulate, at point of manufacture, cumulative channel particle counts:- ≥6 μm(c) Cl-3.2.2, 3.2.6, Table-1 (d) 3) (Particulate, at point of manufacture, cumulative channel particle counts:- ≥14 μm©) Cl-3.2.2, 3.2.6, Table-1 (d) 4) (Particulate, at point of manufacture, cumulative channel particle counts:- ≥21 μm©) Cl-3.2.2, 3.2.6, Table-1 (d) 5) (Particulate, at point of manufacture, cumulative channel particle counts:-≥25 μm©) Cl-3.2.2, 3.2.6, Table-1 (d) 6) (Particulate, at point of manufacture, cumulative channel particle counts:- ≥30 μm©) Cl-3.2.2, 3.2.6, Table-1, (ii) (e) (Doctor Test) Cl-3.2.2, 3.2.6, Table-1, (ii) (f), 1) ("Refining components, at the point of manufacture8) :- Non Hydro processed Components, percent v/v") Cl-3.2.2, 3.2.6, Table-1, (ii) (f), 2) ("Refining components, at the point of manufacture8) :- Mildly Hydro processed Components, percent v/v") Cl-3.2.2, 3.2.6, Table-1, (ii) (f), 3) ("Refining components, at the point of manufacture8) :- Severely Hydro processed Components, percent v/v") Cl-3.2.2, 3.2.6, Table-1, (ii) (f), 4) ("Refining components, at the point of manufacture8) :- Synthetic Components, percenvt/ v") Cl-3.2.2, 3.2.6, Table-1, (vii) (a) (Filter pressure differential, mm Hg, Max) Cl-3.2.2, 3.2.6, Table-1, (vii) (b) 1) (Tube rating, visual (VTR)) Cl-3.2.2, 3.2.6, Table-1, (ix) b), 1) ("Micro-separometer rating18) at the point of manufacture: - MSEP without SDA, Min") Cl-3.2.2, 3.2.6, Table-1, (ix) b), 2) ("Micro-separometer rating18) at the point of manufacture: MSEP with SDA, Min") Cl-3.2.2, 3.2.6, Table- 1, (xi) (Lubricity: Wear scar diameter, mm, Max) Cl-3.2.2, 3.2.6, Table-1, (xii) (Identified Incidental Materials :- Fatty Acid Methyl Ester, mg/kg, Max) Cl-5.2 (Marking) Cl-3.2.2, 3.2.6, Table-1, (vii) (b) 2) (ITR or ETR, average over area of 2.5 mm2 in nm) Amendment No.5 Table 3 Clause G-2.5 i (Thermal stability) Amendment No.5 Table 3 Clause G-2.5 i (Test temperature for 2.5 h) Amendment No.5 Table 3 Clause G-2.5 i (Tube Rating) Amendment No.5 Table 3 Clause G-2.5 i (Annex B VTR) Amendment No.5 Table 3 Clause G-2.5 i (Annex C ITR or Annex D ETR, average over an area of 2.5 mm2) Amendment No.5 Table 3 Clause G-2.5 i (Pressure differential) Amendment No.5 Table 3 Clause G-2.5 ii (Fluidity-Viscosity at - 40 ℃) Amendment No.5 Table 3 Clause G-2.5 iv (Volatility- Distillation-T50 to T10, ℃) Amendment No.5 Table 3 Clause G-2.5 iv (Volatility- Distillation-T90 to T10, ℃) Amendment No.5 Table 3 Clause G-2.5 v (Lubricity) Amendment No.5 Table 3 Clause G-2.5 vi (Unconverted fatty acid esters and fatty acids) Cl-3.2.2, 3.2.6, Table- 1, (xi) (Lubricity: Wear scar diameter, mm (defense requirements)) |
| 1289 |
PLANET ANALYSIS PRIVATE LIMITED, KANPUR
| 9125906
| IS 848 (2025) |
Synthetic Resin Adhesives for Plywood (Phenolic, Aminoplastic and Bio-Materials Based) - Specification ( Third Revision ) |
- |
7500 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| As per Clause 4 Table 1(TYPES) |
- |
0 |
|
5 % DISCOUNT ON TOTAL TESTING CHARGES TO BIS SAMPLES ONLY |
| As per Clause 6.6(SETTING TIMES AND CONDITIONS) |
- |
700 |
|
5 % DISCOUNT ON TOTAL TESTING CHARGES TO BIS SAMPLES ONLY |
| As per Clause 7.3.2 Table 1(i)(Cyclic Test For BWP Type) |
- |
2500 |
|
5 % DISCOUNT ON TOTAL TESTING CHARGES TO BIS SAMPLES ONLY |
| As per Clause 7.3.2 Table 1(ii)(Cyclic Test For BWR Type) |
- |
2000 |
|
5 % DISCOUNT ON TOTAL TESTING CHARGES TO BIS SAMPLES ONLY |
| As per Clause 7.3.2 Table 1(iii)(Cyclic Test For MR Type) |
- |
1500 |
|
5 % DISCOUNT ON TOTAL TESTING CHARGES TO BIS SAMPLES ONLY |
| As per Clause 7.4(Acidity And Alkalinity (pH)) |
- |
1000 |
|
5 % DISCOUNT ON TOTAL TESTING CHARGES TO BIS SAMPLES ONLY |
| As per Clause 9(Marking) |
- |
300 |
|
5 % DISCOUNT ON TOTAL TESTING CHARGES TO BIS SAMPLES ONLY |
| As per Clause 4 Table 1(TYPES) |
- |
0 |
|
5 % DISCOUNT ON TOTAL TESTING CHARGES TO BIS SAMPLES ONLY |
| As per Clause 6.6(SETTING TIMES AND CONDITIONS) |
- |
700 |
|
5 % DISCOUNT ON TOTAL TESTING CHARGES TO BIS SAMPLES ONLY |
| As per Clause 7.3.2 Table 1(i)(Cyclic Test For BWP Type) |
- |
2500 |
|
5 % DISCOUNT ON TOTAL TESTING CHARGES TO BIS SAMPLES ONLY |
| As per Clause 7.3.2 Table 1(ii)(Cyclic Test For BWR Type) |
- |
2000 |
|
5 % DISCOUNT ON TOTAL TESTING CHARGES TO BIS SAMPLES ONLY |
| As per Clause 7.3.2 Table 1(iii)(Cyclic Test For MR Type) |
- |
1500 |
|
5 % DISCOUNT ON TOTAL TESTING CHARGES TO BIS SAMPLES ONLY |
| As per Clause 7.4(Acidity And Alkalinity (pH)) |
- |
1000 |
|
5 % DISCOUNT ON TOTAL TESTING CHARGES TO BIS SAMPLES ONLY |
| As per Clause 9(Marking) |
- |
300 |
|
5 % DISCOUNT ON TOTAL TESTING CHARGES TO BIS SAMPLES ONLY |
| As per Clause 4 Table 1(TYPES) |
- |
0 |
|
5 % DISCOUNT ON TOTAL TESTING CHARGES TO BIS SAMPLES ONLY |
| As per Clause 6.6(SETTING TIMES AND CONDITIONS) |
- |
700 |
|
5 % DISCOUNT ON TOTAL TESTING CHARGES TO BIS SAMPLES ONLY |
| As per Clause 7.3.2 Table 1(i)(Cyclic Test For BWP Type) |
- |
2500 |
|
5 % DISCOUNT ON TOTAL TESTING CHARGES TO BIS SAMPLES ONLY |
| As per Clause 7.3.2 Table 1(ii)(Cyclic Test For BWR Type) |
- |
2000 |
|
5 % DISCOUNT ON TOTAL TESTING CHARGES TO BIS SAMPLES ONLY |
| As per Clause 7.3.2 Table 1(iii)(Cyclic Test For MR Type) |
- |
1500 |
|
5 % DISCOUNT ON TOTAL TESTING CHARGES TO BIS SAMPLES ONLY |
| As per Clause 7.4(Acidity And Alkalinity (pH)) |
- |
1000 |
|
5 % DISCOUNT ON TOTAL TESTING CHARGES TO BIS SAMPLES ONLY |
| As per Clause 9(Marking) |
- |
300 |
|
5 % DISCOUNT ON TOTAL TESTING CHARGES TO BIS SAMPLES ONLY |
|
20 Jan, 2028 |
- Included w.e.f 17.02.2026 |
| 1290 |
Unique Test House LLP
| 9134536
| IS 15961 (2025) |
Hot Dip Aluminium-Zinc Alloy Metallic Coated Steel Strip and Sheet - Specification (First Revision) |
ALL SIZES |
7500 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl-3.5(Surface Finish) |
- |
200 |
|
............... |
| Cl-4(Supply of Material - General requirements) |
- |
200 |
|
.................... |
| Cl-5(Manufacture) |
- |
200 |
|
....................... |
| Cl-7(C) |
- |
200 |
|
........................ |
| Cl-7(Mn) |
- |
200 |
|
.............................. |
| Cl-7(S) |
- |
200 |
|
....................... |
| Cl-7(P) |
- |
200 |
|
............................ |
| Cl-7(Total aluminium) |
- |
200 |
|
.......................... |
| Cl-7(silicon) |
- |
200 |
|
......................................... |
| Cl-7(Nitrogen) |
- |
200 |
|
............................. |
| Cl-7(Chromium,) |
- |
200 |
|
...................................................... |
| Cl-7(Nickel,) |
- |
200 |
|
........................ |
| Cl-7(Niobium,) |
- |
200 |
|
........................ |
| Cl-7(Vanadium,) |
- |
200 |
|
................................ |
| Cl-7(Titanium,) |
- |
200 |
|
.................................. |
| Cl-7(Molybdenum,) |
- |
200 |
|
............................................ |
| Cl-7(Boron,) |
- |
200 |
|
.................................... |
| Cl-7(Calcium) |
- |
200 |
|
............................... |
| Cl-7(others,) |
- |
200 |
|
........................... |
| Cl-7(Phosphorus) |
- |
200 |
|
.......................... |
| Cl-8.1(Test Piece) |
- |
200 |
|
............................. |
| Cl-8.2(Testing Frequency) |
- |
300 |
|
............................ |
| Cl-8.3, Table-1(Yield Strength) |
- |
400 |
|
............................. |
| Cl-8.3, Table-1(Tensile Strength) |
- |
500 |
|
................................ |
| Cl-8.3, Table-1(Elongation,) |
- |
200 |
|
.......................... |
| Cl-9(Coating Test) |
- |
300 |
|
............................. |
| Cl-9.1, Table-2(Minimum Coating Mass (Total Both Surfaces)- Triple Spot) |
- |
300 |
|
.............................. |
| Cl-9.1, Table-2(Minimum Coating Mass (Total Both Surfaces)- Single Spot) |
- |
300 |
|
........................ |
| Cl-9.1, Table-2(Minimum Coating Mass (One Surface) -Single Spot) |
- |
300 |
|
............................ |
| Cl-9.4(Single Spot Coating Mass) |
- |
300 |
|
.......................... |
| Cl-9.5(Triple Spot Coating Mass) |
- |
300 |
|
............................... |
| Cl-9.6(Differential Coating) |
- |
300 |
|
............................ |
| Cl-10(Coating Adhesion Test) |
- |
300 |
|
............................ |
| Cl-11(Freedom From Defects) |
- |
100 |
|
................................ |
| Cl-12(Mass) |
- |
300 |
|
............................ |
| Cl-13.1(Coil Internal Diameter) |
- |
300 |
|
......................... |
| Cl-13.2(Length Tolerance) |
- |
300 |
|
............................ |
| Cl-13.3(Width Tolerance) |
- |
300 |
|
......................... |
| Cl-13.4(Thickness Tolerance) |
- |
300 |
|
............................. |
| Cl-13.5(Camber) |
- |
300 |
|
.............................. |
| Cl-13.6(Deviation from Squareness (Out-of Square)) |
- |
150 |
|
............................. |
| Cl-13.7(Deviation from Flatness (Steepness)) |
- |
150 |
|
.............................. |
| Cl-13.8(Profiled Sheets) |
- |
100 |
|
.......................... |
| Cl-16(Marking) |
- |
100 |
|
................................... |
|
07 Sep, 2028 |
- Included w.e.f 22.01.2026 |