| 1321 |
EKO PRO ENGINEERS PRIVATE LIMITED (32/37) GHAZIABAD
| 8164006
| IS 2385 (1977) |
Specification for hot - Rolled mild steel sheet and strip in coil form for cold - Reduced tinplate and cold - Reduced blackplate (First Revision) |
All Grade |
4000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl. 5.1, 5.2 & Table1(Carbon- Appropriate parts of IS 228 or any other established Instrumental/Chemical method.) |
- |
4000 |
|
- |
| Cl. 5.1, 5.2 & Table1(Manganese- Appropriate parts of IS 228 or any other established Instrumental/Chemical method.) |
- |
4000 |
|
- |
| Cl. 5.1, 5.2 & Table1(Sulphur- Appropriate parts of IS 228 or any other established Instrumental/Chemical method.) |
- |
4000 |
|
- |
| Cl. 5.1, 5.2 & Table1(Phosphorus- Appropriate parts of IS 228 or any other established Instrumental/Chemical method.) |
- |
4000 |
|
- |
| Cl. 5.1, 5.2 & Table1(Nitrogen- Appropriate parts of IS 228 or any other established Instrumental/Chemical method.) |
- |
4000 |
|
- |
| Cl. 5.1, 5.2 & Table1(Aluminium- Appropriate parts of IS 228 or any other established Instrumental/Chemical method.) |
- |
4000 |
|
- |
| 6(Freedom from defects) |
- |
4000 |
|
- |
| 8(Dimensions and Tolerances) |
- |
4000 |
|
- |
| Cl. 5.1, 5.2(chromium) |
- |
4000 |
|
- |
| Cl. 5.1, 5.2(silicon) |
- |
4000 |
|
- |
| Cl. 5.1, 5.2(copper) |
- |
4000 |
|
- |
| Cl. 5.1, 5.2(aluminium) |
- |
4000 |
|
- |
| Cl. 5.1, 5.2(Nitrogen ) |
- |
4000 |
|
- |
| Cl. 5.1, 5.2(Phosphorus) |
- |
4000 |
|
- |
| Cl. 5.1, 5.2(Sulphur) |
- |
4000 |
|
- |
| Cl. 5.1, 5.2(Manganese) |
- |
4000 |
|
- |
| Cl. 5.1, 5.2(carbon) |
- |
4000 |
|
- |
|
27 May, 2028 |
- - |
| 1322 |
EKO PRO ENGINEERS PRIVATE LIMITED (32/37) GHAZIABAD
| 8164006
| IS 12406 (2021) |
Medium density fibre boards for general purpose - Specification |
Grade 1/Grade 2/E1/E2 |
8200 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Clauses 5.2, 9 and 10.2.2(Density) |
- |
8200 |
|
- |
| Clauses 5.2, 9 and 10.2.2(Density) |
- |
8200 |
|
- |
| Clauses 5.2, 9 and 10.2.2(Variation from mean density) |
- |
8200 |
|
- |
| Clauses 5.2, 9 and 10.2.2(Moisture Content) |
- |
8200 |
|
- |
| Clauses 5.2, 9 and 10.2.2(Variation from mean moisture content) |
- |
8200 |
|
- |
| Clauses 5.2, 9 and 10.2.2(Linear expansion
(Thickness Swelling in Water)
Due to general Absorption after 24h soaking) |
- |
8200 |
|
- |
| Clauses 5.2, 9 and 10.2.2(Internal Bond Strength) |
- |
8200 |
|
- |
| Clauses 5.2, 9 and 10.2.2(Internal Bond strength
(i) (After Cyclic test)
(ii) (After accelerated water resistance test)) |
- |
8200 |
|
- |
| Clauses 5.2, 9 and 10.2.2(Modulus of Rupture
a) Avg. Value
b) Min. Individual) |
- |
8200 |
|
- |
| Clauses 5.2, 9 and 10.2.2(Modulus of Elasticity
a) Avg. Value
b) Min. Individual) |
- |
8200 |
|
- |
| Clauses 5.2, 9 and 10.2.2(Screw withdrawl strength
(i) Face
(ii) Edge (For thickness >12mm)) |
- |
8200 |
|
- |
| Clauses 5.2, 9 and 10.2.2(Formaldehyde Content
(i) For Formaldehyde Class, E1
(ii) For Formaldehyde Class, E2) |
- |
8200 |
|
- |
| 8(DIMENSIONS AND TOLERANCES) |
- |
8200 |
|
- |
| Cl-11(ADDITIONAL REQUIREMENTS FOR
ECO-MARK) |
- |
8200 |
|
- |
| Cl 7(Finish) |
- |
8200 |
|
- |
|
27 May, 2028 |
- - |
| 1323 |
EKO PRO ENGINEERS PRIVATE LIMITED (32/37) GHAZIABAD
| 8164006
| IS 3087 (2025) |
Medium Density Particle Boards of Wood and other Lignocellulosic Materials for General Purpose - Specification ( Third Revision ) |
REG -GRADE-A , REG GRADE-B , MR Grade, HMR Grade |
10500 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| As per Clause 7(Finish --IS 2380 (Part 2), IS 2380 (Part 3) & Visual) |
- |
10500 |
|
- |
| As per Clause 8, Table 2(Length -IS 2380 (Part 2)) |
- |
10500 |
|
- |
| As per Clause 8, Table 2(Width - IS 2380 (Part 2)) |
- |
10500 |
|
- |
| As per Clause 8, Table 2(Thickness, Sanded/finished panel - IS 2380 (Part 2)) |
- |
10500 |
|
- |
| As per Clause 8, Table 2(Squareness, Max. - IS 2380 (Part 2)) |
- |
10500 |
|
- |
| As per Clause 8, Table 2(Edge straightness, Max. -IS 2380 (Part 2)) |
- |
10500 |
|
- |
| As per Clause 9.1 Table 3(Density -IS 2380 (Part 3)) |
- |
10500 |
|
- |
| As per Clause 9.1 Table 3(Variation from mean density, --IS 2380 (Part 3)) |
- |
10500 |
|
- |
| As per Clause 9.1 Table 3(Moisture Content -IS 2380 (Part 3)) |
- |
10500 |
|
- |
| As per Clause 9.1 Table 4, Table 5, Table 6, Table 7(Modulus of rupture (MoR), Min.-IS 2380 (Part 4)) |
- |
10500 |
|
- |
| As per Clause 9.1 Table 4, Table 6, Table 7(Modulus of elasticity (MoE), Min. -(IS 2380 (Part 4)) |
- |
10500 |
|
- |
| As per Clause 9.1 Table 4, Table 5, Table 6, Table7(Internal bond strength, Min. - IS 2380 (Part 5)) |
- |
10500 |
|
- |
| As per Clause 9.1 Table 6, Table 7(24 h thickness swelling (due to general absorption) Max. - IS 2380 (Part 17)) |
- |
10500 |
|
- |
| As per Clause 9.1 Table 4, Table 5, Table 6, Table 7(Screw withdrawal strength (face) , Min. -IS 2380 (Part 4)) |
- |
10500 |
|
- |
| As per Clause 9.1 Table 4, Table 5, table 6, Table 7(Screw withdrawal strength (edge) , Min. -IS 2380 (Part 4)) |
- |
10500 |
|
- |
| As per Clause 9.1 , Table 6, Table 7(Moisture Resistance : Option 1 : Cyclic test (1. )Internal bond strength Min. -IS 2380 (Part 5) see note 1) |
- |
10500 |
|
- |
| As per Clause 9.1 , Table 6, Table 7(Moisture Resistance : Option 2 : Boil test (1.) Internal bond strength , Min.- IS 2380 (Part 5) see note 2) |
- |
10500 |
|
- |
| As per Clause 9.1 , Table 9(Formaldehyde content Fc, mg/100 g for oven dry board -IS 13745) |
- |
10500 |
|
- |
|
27 May, 2028 |
- - |
| 1324 |
EKO PRO ENGINEERS PRIVATE LIMITED (32/37) GHAZIABAD
| 8164006
| IS 4923 (2017) |
Hollow steel sections for structural use - Specification (Third Revision) |
All Grade |
6800 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl.7.1(Carbon- IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
6800 |
|
- |
| Cl.7.1(Manganese- IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
6800 |
|
- |
| Cl.7.1(Sulphur- IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
6800 |
|
- |
| Cl.7.1(Phosphorus- IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
6800 |
|
- |
| Cl.7.1(Silicon- IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
6800 |
|
- |
| Cl.7.1(Aluminium- IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
6800 |
|
- |
| Cl.7.1(Copper- IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
6800 |
|
- |
| Cl.7.1(Niobium- IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
6800 |
|
- |
| Cl.7.1(Vanadium- IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
6800 |
|
- |
| Cl.7.1(Titanium- IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
6800 |
|
- |
| Cl.7.1(Nitrogen- IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
6800 |
|
- |
| Cl.7.1(Carbon Equivalent-IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
6800 |
|
- |
| Cl.9.1, Table 1(Dimensions and Properties of Hollow Sections (Depth)) |
- |
6800 |
|
- |
| Cl.9.1, Table 1(Dimensions and Properties of Hollow Sections (Width)) |
- |
6800 |
|
- |
| Cl.9.1, Table 1(Dimensions and Properties of Hollow Sections(Thickness)) |
- |
6800 |
|
- |
| Cl.9.1, Table 1(Dimensions and Properties of Hollow Sections (Weigth)) |
- |
6800 |
|
- |
| Cl.9.1, Table 1(Dimensions and Properties of Hollow Sections (Area of Section)) |
- |
6800 |
|
- |
| Cl.9.1, Table 1(Dimensions and Properties of Hollow Sections (Moment of Inertia)) |
- |
6800 |
|
- |
| Cl.9.1, Table 1(Dimensions and Properties of Hollow Sections (Moment of Inertia about X-X)) |
- |
6800 |
|
- |
| Cl.9.1, Table 1(Dimensions and Properties of Hollow Sections (Moment of Inertia about Y-Y)) |
- |
6800 |
|
- |
| Cl.9.1, Table 1(Dimensions and Properties of Hollow Sections (Radius of Gyration)) |
- |
6800 |
|
- |
| Cl.9.1, Table 1(Dimensions and Properties of Hollow Sections (Radius of Gyration about X-X)) |
- |
6800 |
|
- |
| Cl.9.1, Table 1(Dimensions and Properties of Hollow Sections(Radius of Gyration about Y-Y)) |
- |
6800 |
|
- |
| Cl.9.1, Table 1(Dimensions and Properties of Hollow Sections(Elastic Modulus)) |
- |
6800 |
|
- |
| Cl.9.1, Table 1(Dimensions and Properties of Hollow Sections (Elastic Modulus about X-X)) |
- |
6800 |
|
- |
| Cl.9.1, Table 1(Dimensions and Properties of Hollow Sections (Elastic Modulus about Y-Y)) |
- |
6800 |
|
- |
| Cl.9.1, Table 1(Dimensions and Properties of Hollow Sections (Plastic Modulus)) |
- |
6800 |
|
- |
| Cl.9.1, Table 1(Dimensions and Properties of Hollow Sections (Plastic Modulus about X-X)) |
- |
6800 |
|
- |
| Cl.9.1, Table 1(Dimensions and Properties of Hollow Sections(Plastic Modulus about Y-Y)) |
- |
6800 |
|
- |
| Cl. 10.1, 14.1, 18.1(Straightness) |
- |
6800 |
|
- |
| Cl. 10.2, Fig 1(Outside dimension (B)) |
- |
6800 |
|
- |
| Cl. 10.2, Fig 1(Outside dimension (H)) |
- |
6800 |
|
- |
| Cl. 10.2, Fig 1(Outside dimension (T)) |
- |
6800 |
|
- |
| Cl. 10.4, Fig 2(Concavity, X1) |
- |
6800 |
|
- |
| Cl. 10.4, Fig 2(Convexity, X2) |
- |
6800 |
|
- |
| Cl. 10.5, Fig 3(Squareness of side) |
- |
6800 |
|
- |
| Cl. 10.6, Fig 4(External Corner Radius) |
- |
6800 |
|
- |
| Cl. 10.7, Fig 5(Total twist, V) |
- |
6800 |
|
- |
| Cl. 15.2, Table 3(Tensile Strength- IS 1608) |
- |
6800 |
|
- |
| Cl. 15.2, Table 3(Yield Strength- IS 1608) |
- |
6800 |
|
- |
| Cl. 15.2, Table 3(Elongation- IS 1608) |
- |
6800 |
|
- |
| Cl. 14.1(Exact Length) |
- |
6800 |
|
- |
| Cl. 14.1(Random Length) |
- |
6800 |
|
- |
| Cl. 14.1(Weight on individual length) |
- |
6800 |
|
- |
| Cl. 14.1(Weight on lots of 10 tonnes min) |
- |
6800 |
|
- |
| Cl. 18, Note 2(Internal Fin Height (Only for Cold Formed)) |
- |
6800 |
|
- |
| 7(Micro Alloying elements(Nb+V+Ti)) |
- |
6800 |
|
- |
| 7(Carbon equivalent as CE) |
- |
6800 |
|
- |
| 10.4(Concavity/Convexity-SOP MT-23) |
- |
6800 |
|
- |
| 10.5(Squareness of corner/Sides-SOP MT-23) |
- |
6800 |
|
- |
| 10.6("External corner Radius/
Radii of corners-outside
- SOP MT-23") |
- |
6800 |
|
- |
| 11(Oiling & Painting - IS 4923) |
- |
6800 |
|
- |
| 18.1(Height of the internal weld fin - IS 4923) |
- |
6800 |
|
- |
| 10.3(Thickness - IS 4923) |
- |
6800 |
|
- |
| 13(Marking) |
- |
6800 |
|
- |
| Cl-19(Mechanical Tests) |
- |
6800 |
|
- |
|
27 May, 2028 |
- - |
| 1325 |
EKO PRO ENGINEERS PRIVATE LIMITED (32/37) GHAZIABAD
| 8164006
| IS 12817 (2020) |
Stainless Steel Butt Hinges - Specification ( Third Revision ) |
All Type |
9800 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 6.2, Table 1 to 6(Length , A -IS 12817) |
- |
9800 |
|
- |
| 6.2, Table 1 to 6(Breadth, B-IS 12817) |
- |
9800 |
|
- |
| 6.2, Table 1 to 6(Breadth, B1-IS 12817) |
- |
9800 |
|
- |
| 6.2, Table 1 to 6(Breadth, B2-IS 12817) |
- |
9800 |
|
- |
| 6.2, Table 1 to 6(Thickness of flap, C-IS 12817) |
- |
9800 |
|
- |
| 6.2, Table 1 to 6(Dia. of Hinge pin, D-IS 12817 ) |
- |
9800 |
|
- |
| 6.2, Table 1 to 6(Number of Knuckles- IS 12817 ) |
- |
9800 |
|
- |
| 6.2, Table 1 to 6(Number of Screw Holes -IS 12817 ) |
- |
9800 |
|
- |
| 6.2, Table 1 to 6(Holes for Screw Number- IS 12817 ) |
- |
9800 |
|
- |
| 7.1(General - IS 12817 ) |
- |
9800 |
|
- |
| 7.2(Knuckles - IS 12817 ) |
- |
9800 |
|
- |
| 7.3(Pins- IS 12817 ) |
- |
9800 |
|
- |
| 7.4(Screw Holes- IS 12817 ) |
- |
9800 |
|
- |
| 7.4.2(Position of screw holes - IS 12817 ) |
- |
9800 |
|
- |
| 7.4.2, Fig 1(The distance of the screw holes from the end of the flap - IS 12817 ) |
- |
9800 |
|
- |
| 8.0(Finish - IS 12817 ) |
- |
9800 |
|
- |
| Clause 4.1.2(Silicon (Pin) ) |
- |
9800 |
|
- |
| Clause 4.1.2(Phosphorus (Pin) ) |
- |
9800 |
|
- |
| Clause 4.1.2(Sulphur (Pin) ) |
- |
9800 |
|
- |
| Clause 4.1.2(Manganese (Pin) ) |
- |
9800 |
|
- |
| Clause 4.1.2(Carbon (Pin) ) |
- |
9800 |
|
- |
| Clause 4.1.1(Silicon (Flap) ) |
- |
9800 |
|
- |
| Clause 4.1.1(Phosphorus (Flap) ) |
- |
9800 |
|
- |
| Clause 4.1.1(Sulphur (Flap) ) |
- |
9800 |
|
- |
| Clause 4.1.1(Manganese (Flap) ) |
- |
9800 |
|
- |
| Clause 4.1.1(Carbon (Flap) ) |
- |
9800 |
|
- |
| Clause 7.4.2 (Dimension - Z ) |
- |
9800 |
|
- |
| Clause 7.4.2 (Dimension - Y ) |
- |
9800 |
|
- |
| Clause 7.4.2 (Dimension - X ) |
- |
9800 |
|
- |
| Clause 7.4.1(Number of holes) |
- |
9800 |
|
- |
| As per Cl.4(Carbon) |
- |
9800 |
|
- |
| As per Cl.4(Sulphur) |
- |
9800 |
|
- |
| As per Cl.4(Phosphorus) |
- |
9800 |
|
- |
| As per Cl.4(Manganese) |
- |
9800 |
|
- |
| As per Cl.4(Nitrogen) |
- |
9800 |
|
- |
| As per Cl.4(Silicon) |
- |
9800 |
|
- |
| As per Cl.4(Aluminium) |
- |
9800 |
|
- |
| As per Cl.4(Chromium) |
- |
9800 |
|
- |
| As per Cl.4(Vanadium) |
- |
9800 |
|
- |
| As per Cl.4(Molybdenum) |
- |
9800 |
|
- |
| As per Cl.4(Niobium) |
- |
9800 |
|
- |
| As per Cl.4(Nickel) |
- |
9800 |
|
- |
| As per Cl.4(Copper) |
- |
9800 |
|
- |
| As per Cl.4(Titanium) |
- |
9800 |
|
- |
| As per Cl.4(Zirconium) |
- |
9800 |
|
- |
| As per Cl.4(Tungsten) |
- |
9800 |
|
- |
| As per Cl.4(Cerium) |
- |
9800 |
|
- |
| Cl.4(Other Elements - IS 228 and its parts or any other intrumental/chemical methods) |
- |
9800 |
|
- |
|
27 May, 2028 |
- - |
| 1326 |
EKO PRO ENGINEERS PRIVATE LIMITED (32/37) GHAZIABAD
| 8164006
| IS 432 : Part 1 (1982) |
Mild Steel and Medium Tensile Steel Bars and Hard-Drawn Steel Wire for Concrete Reinforcement: Part 1 Mild Steel and Medium Tensile Steel Bars |
All Designation |
2490 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl 5.1(Workmanship) |
- |
2490 |
|
- |
| Cl 6.2(Diameter & Ovality) |
- |
2490 |
|
- |
| Cl 6.2(Weight) |
- |
2490 |
|
- |
| Cl 8.2(Bend test) |
- |
2490 |
|
- |
| Cl 9.3(Press) |
- |
2490 |
|
- |
| Cl 5.1(Workmanship) |
- |
2490 |
|
- |
| Cl 6.1(Diameter) |
- |
2490 |
|
- |
| Cl 6.2(Weight) |
- |
2490 |
|
- |
| Cl 8.1(ultimate tensile stress, yield stress and percentage elongation) |
- |
2490 |
|
- |
| Cl 9.3(Press) |
- |
2490 |
|
- |
| Cl 5.1(Workmanship) |
- |
2490 |
|
- |
| Cl 6.2(Diameter & Ovality) |
- |
2490 |
|
- |
| Cl 6.2(Weight) |
- |
2490 |
|
- |
| Cl 8(Physical Requirements) |
- |
2490 |
|
- |
| Cl 9.3(Press) |
- |
2490 |
|
- |
| Clause -4, 4.3(TITANIUM) |
- |
2490 |
|
- |
| Clause -4, 4.2(VANADIUM) |
- |
2490 |
|
- |
| Clause -4, 4.1(NIOBIUM) |
- |
2490 |
|
- |
| Clause -4, 4.1(Molybdenum) |
- |
2490 |
|
- |
| Clause -4, 4.1(Chromium) |
- |
2490 |
|
- |
| Clause -4, 4.1(Nickel) |
- |
2490 |
|
- |
| Clause -4, 4.1( ALUMINIUM) |
- |
2490 |
|
- |
| Clause -4, 4.1(SILICON) |
- |
2490 |
|
- |
| Clause -4, 4.1(NITROGEN) |
- |
2490 |
|
- |
| Clause -4, 4.1(MANGANESE) |
- |
2490 |
|
- |
| Clause -4, 4.1(SULPHUR) |
- |
2490 |
|
- |
| Clause -4, 4.1( CARBON) |
- |
2490 |
|
- |
| Cl. 8.1 Table 1(Elongation) |
- |
2490 |
|
- |
| Cl. 8.1 Table 1(Yield Stress) |
- |
2490 |
|
- |
| Clause 8.1(Elongation) |
- |
2490 |
|
- |
| Clause 8.1(Yield Stress) |
- |
2490 |
|
- |
| Clause 9.3(Bend test) |
- |
2490 |
|
- |
| Clause 6.1(Size) |
- |
2490 |
|
- |
| Cl 9.3(Press) |
- |
2490 |
|
- |
| Cl 8(UTM) |
- |
2490 |
|
- |
| Cl 6.2(Weight) |
- |
2490 |
|
- |
| Cl 6.2(Diameter & Ovality) |
- |
2490 |
|
- |
| Cl 5.1(Workmanship) |
- |
2490 |
|
- |
| 7(Tolerance) |
- |
2490 |
|
- |
| Cl 5.1(Workmanship) |
- |
2490 |
|
- |
| Cl 6.2(Diameter & Ovality) |
- |
2490 |
|
- |
| Cl 6.2(Weight) |
- |
2490 |
|
- |
| Cl 8(UTM) |
- |
2490 |
|
- |
| Cl 9.3(Press) |
- |
2490 |
|
- |
| Cl 4.1(Workmanship) |
- |
2490 |
|
- |
| Cl 5 & 6(Diameter) |
- |
2490 |
|
- |
| Cl 7(UTM) |
- |
2490 |
|
- |
| Cl 8.3(Bending To Both Side At 90°, Then Straight) |
- |
2490 |
|
- |
| Clause 5.1(IS 432 Part 1) |
- |
2490 |
|
- |
| Clause 6.2(IS 1732) |
- |
2490 |
|
- |
| Clause 8.1(IS 1608 Part 1) |
- |
2490 |
|
- |
| Clause 4(Any Instrumental Method/Chemical Method) |
- |
2490 |
|
- |
| Clause 4(By Calculation) |
- |
2490 |
|
- |
| Clause 4(By Calculation) |
- |
2490 |
|
- |
| Clause 4(Any Instrumental Method/Chemical Method) |
- |
2490 |
|
- |
| Clause 5.1(Freedom from Defect) |
- |
2490 |
|
- |
| Clause 6.2(Mass) |
- |
2490 |
|
- |
| Clause 8.1(Ultimate Tensile Stress) |
- |
2490 |
|
- |
| Clause 4(Boron) |
- |
2490 |
|
- |
| Clause 4(By Calculation) |
- |
2490 |
|
- |
| Clause 4(By Calculation) |
- |
2490 |
|
- |
| Clause 4(Copper) |
- |
2490 |
|
- |
| 8.1 & 9.2(Yield Strength - IS: 1608 (P1)) |
- |
2490 |
|
- |
| 8.1 & 9.2(Elongation on SoA 5.65mm GL - IS: 1608 (P1)) |
- |
2490 |
|
- |
| 11(Marking) |
- |
2490 |
|
- |
| Clause 5.1(Freedom from Defect) |
- |
2490 |
|
- |
| Clause 6.2(Mass) |
- |
2490 |
|
- |
| Clause 8.1(Ultimate Tensile Stress) |
- |
2490 |
|
- |
| Clause 4(Boron) |
- |
2490 |
|
- |
| Clause 4(Carbon Equivalent) |
- |
2490 |
|
- |
| Clause 4(Ni+V+Ti) |
- |
2490 |
|
- |
| Clause 4(Copper) |
- |
2490 |
|
- |
| Clause 4(Copper) |
- |
2490 |
|
- |
| Clause -4, 4.1(PHOSPHURS) |
- |
2490 |
|
- |
|
27 May, 2028 |
- - |
| 1327 |
EKO PRO ENGINEERS PRIVATE LIMITED (32/37) GHAZIABAD
| 8164006
| IS 6754 (1972) |
Specification for aluminium alloy ingots for bearings |
All Designation |
6300 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 2.1(General requirements) |
- |
6300 |
|
- |
| 3.1(Manufacture) |
- |
6300 |
|
- |
| 4.1(Chemical composition) |
- |
6300 |
|
- |
| 5.1(Shape and size) |
- |
6300 |
|
- |
| 6(Freedom from Defects) |
- |
6300 |
|
- |
| 7(Selection of Sample for chemical analysis) |
- |
6300 |
|
- |
| 8(Retest) |
- |
6300 |
|
- |
| 9(Marking) |
- |
6300 |
|
- |
| Table-1, Clause - 4.1(Copper) |
- |
6300 |
|
- |
| Table-1, Clause - 4.1(Magnesium) |
- |
6300 |
|
- |
| Table-1, Clause - 4.1(Manganese) |
- |
6300 |
|
- |
| Table-1, Clause - 4.1(Titanium) |
- |
6300 |
|
- |
| Table-1, Clause - 4.1(Silicon) |
- |
6300 |
|
- |
| Table-1, Clause - 4.1(Nickel) |
- |
6300 |
|
- |
| Table-1, Clause - 4.1(Tin) |
- |
6300 |
|
- |
| Table-1, Clause - 4.1(Other elements) |
- |
6300 |
|
- |
| Table-1, Clause - 4.1(Total of Fe+Si+Mn) |
- |
6300 |
|
- |
| Table-1, Clause - 4.1(Aluminium) |
- |
6300 |
|
- |
|
27 May, 2028 |
- - |
| 1328 |
EKO PRO ENGINEERS PRIVATE LIMITED (32/37) GHAZIABAD
| 8164006
| IS 3502 (2009) |
Steel chequered plates (Third Revision) |
All Grade |
5900 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl 5(Workmanship) |
- |
5900 |
|
- |
| Cl 6(Workmanship) |
- |
5900 |
|
- |
| Cl 8(Tensile Test) |
- |
5900 |
|
- |
| Cl 9(Press) |
- |
5900 |
|
- |
| Cl 10(Length, Width, Thickness & Chequered Height) |
- |
5900 |
|
- |
| Cl 5(Workmanship) |
- |
5900 |
|
- |
| Cl 6(Workmanship) |
- |
5900 |
|
- |
| Cl 8(Tensile Test) |
- |
5900 |
|
- |
| Cl 9(Press) |
- |
5900 |
|
- |
| Cl 10(Length, Width, Thickness & Chequered Height) |
- |
5900 |
|
- |
| Cl 5(Workmanship) |
- |
5900 |
|
- |
| Cl 6(Workmanship) |
- |
5900 |
|
- |
| Cl 8(Tensile Test) |
- |
5900 |
|
- |
| Cl 9(Press) |
- |
5900 |
|
- |
| Cl 10(Length, Width, Thickness & Chequered Height) |
- |
5900 |
|
- |
| Cl. 11(Weight) |
- |
5900 |
|
- |
| Cl. 10(Thickness) |
- |
5900 |
|
- |
| Cl. 10(Width) |
- |
5900 |
|
- |
| Cl.8(Elongation) |
- |
5900 |
|
- |
| Cl.8(Yield Stress) |
- |
5900 |
|
- |
| 4.1(Grade E 250A of IS 2062.) |
- |
5900 |
|
- |
| Cl 10(Length, Width, Thickness & Chequered Height) |
- |
5900 |
|
- |
| Cl 9(Press) |
- |
5900 |
|
- |
| Cl 8(Tensile Test) |
- |
5900 |
|
- |
| Cl 6(Workmanship) |
- |
5900 |
|
- |
| Cl 5(Workmanship) |
- |
5900 |
|
- |
| Cl.4.1 (IS-2062, E250A)(CARBON) |
- |
5900 |
|
- |
| Cl.4.1 (IS-2062, E250A)(SULPHUR) |
- |
5900 |
|
- |
| Cl.4.1 (IS-2062, E250A)(PHOSPHURS) |
- |
5900 |
|
- |
| Cl.4.1 (IS-2062, E250A)(MANGANESE) |
- |
5900 |
|
- |
| Cl.4.1 (IS-2062, E250A)(SILICON) |
- |
5900 |
|
- |
| Cl.4.1 (IS-2062, E250A)(CARBON EQUIVALENT) |
- |
5900 |
|
- |
| Cl.4.1 (IS-2062, E250A)(NITROGEN) |
- |
5900 |
|
- |
| Cl 5(Workmanship) |
- |
5900 |
|
- |
| Cl 6(Workmanship) |
- |
5900 |
|
- |
| Cl 8(UTM) |
- |
5900 |
|
- |
| Cl 9(Press) |
- |
5900 |
|
- |
| Cl 10(Length, Width, Thickness & Chequered Height) |
- |
5900 |
|
- |
| 4(Carbon as C) |
- |
5900 |
|
- |
| 4(Manganese as Mn) |
- |
5900 |
|
- |
| 4(Sulphur as S) |
- |
5900 |
|
- |
| 4(Phosphorus as P) |
- |
5900 |
|
- |
| 4(Silicon as Si) |
- |
5900 |
|
- |
| 4(Aluminium as Al) |
- |
5900 |
|
- |
| 4(Micro Alloying elements) |
- |
5900 |
|
- |
| 4(Niobium as Nb) |
- |
5900 |
|
- |
| 4(Vanadium as V) |
- |
5900 |
|
- |
| 4(Titanium as Ti) |
- |
5900 |
|
- |
| 4(Nitrogen content) |
- |
5900 |
|
- |
| 8(Tensile Strength-IS:1608(P1)-22) |
- |
5900 |
|
- |
| 8(Yield Stress-IS:1608(P1)-22) |
- |
5900 |
|
- |
| 8(Elongation on SoA 5.65mm GL) |
- |
5900 |
|
- |
| 10(Length - SOP MT-23) |
- |
5900 |
|
- |
| 10(Width - SOP MT-23) |
- |
5900 |
|
- |
| 10(Thickness- SOP MT-23) |
- |
5900 |
|
- |
| 10(Mass -SOP MT-23) |
- |
5900 |
|
- |
| 10(Chequred Height - SOP MT-23) |
- |
5900 |
|
- |
| 10(Chequred Height - SOP MT-23) |
- |
5900 |
|
- |
| Cl 4.1(Carbon- IS 228(Part 1)) |
- |
5900 |
|
- |
| Cl 4.1(Sulphur- IS 228(Part 9)) |
- |
5900 |
|
- |
| Cl 4.1(Phosphorous- IS 228(Part 3)) |
- |
5900 |
|
- |
| Cl 4.1(Manganese- IS 228(Part 2)) |
- |
5900 |
|
- |
| Cl 4.1(Carbon Equivalent (CE)) |
- |
5900 |
|
- |
| Cl 4.1(Silicon- IS 228(Part 2)) |
- |
5900 |
|
- |
| Cl 4.1(Nitrogen -IS 228(Part 19)) |
- |
5900 |
|
- |
|
27 May, 2028 |
- - |
| 1329 |
EKO PRO ENGINEERS PRIVATE LIMITED (32/37) GHAZIABAD
| 8164006
| IS 206 (2010) |
Tee and strap hinges - Specification (Fifth Revision) |
All Grade |
3400 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 5(DIMENSIONS AND TOLERANCES) |
- |
3400 |
|
- |
| 6(WORKMANSHIP) |
- |
3400 |
|
- |
| 7(FINISH) |
- |
3400 |
|
- |
| 10(MARKING) |
- |
3400 |
|
- |
| Clause 3.1,1(Light weight
(Type 1)) |
- |
3400 |
|
- |
| Clause 3.1,2(Light weight
(Type 2)) |
- |
3400 |
|
- |
| Clause 3.1,3(Medium weight
(Type 1)) |
- |
3400 |
|
- |
| Clause 3.1,4(Medium weight
(Type 2)) |
- |
3400 |
|
- |
| Clause 3.1,5(Heavy weight
(Type 1)) |
- |
3400 |
|
- |
| Clause 3.1,6(Heavy weight
(Type 2)) |
- |
3400 |
|
- |
| Clause 3.1,7(Heavy weight
(Type 3)) |
- |
3400 |
|
- |
| Clause 3.2,1(Light weight) |
- |
3400 |
|
- |
| Clause 3.2,2(Medium weight
(Type 1)) |
- |
3400 |
|
- |
| Clause 3.2,3(Medium weight
(Type 2)) |
- |
3400 |
|
- |
| Clause 3.2,4(Heavy weight ) |
- |
3400 |
|
- |
| Clause 4
Table 1(i)(Mild steel sheet) |
- |
3400 |
|
- |
| Clause 4
Table 1(ii)(Mild steel wire) |
- |
3400 |
|
- |
| Clause 5.1(Dimensions) |
- |
3400 |
|
- |
| Clause 6(Workmanship) |
- |
3400 |
|
- |
| Clause 8(Packing) |
- |
3400 |
|
- |
| Clause 9(SAMPLING AND CRITERION FOR CONFORMITY) |
- |
3400 |
|
- |
| Clause 10(Marking) |
- |
3400 |
|
- |
|
27 May, 2028 |
- - |
| 1330 |
EKO PRO ENGINEERS PRIVATE LIMITED (32/37) GHAZIABAD
| 8164006
| IS 13983 (1994) |
Stainless Steel Sinks For Domestic Purposes |
A1,A2,B1,B2,C,D,E1,E2,E3,F |
6900 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 9(Marking) |
- |
6900 |
|
- |
| 4(Type) |
- |
6900 |
|
- |
| Cl. 5 , As per IS 5522-2014, Cl. 7.2 , Table 1 & 2 Grade Desig X-04-Cr-19-Ni-19 (Numeric Symbol 304)(Carbon Content) |
- |
6900 |
|
- |
| Cl. 5 , As per IS 5522-2014, Cl. 7.2 , Table 1 & 2 Grade Desig X-04-Cr-19-Ni-19 (Numeric Symbol 304)(Silicon Content) |
- |
6900 |
|
- |
| Cl. 5 , As per IS 5522-2014, Cl. 7.2 , Table 1 & 2 Grade Desig X-04-Cr-19-Ni-19 (Numeric Symbol 304)(Manganese Content) |
- |
6900 |
|
- |
| Cl. 5 , As per IS 5522-2014, Cl. 7.2 , Table 1 & 2 Grade Desig X-04-Cr-19-Ni-19 (Numeric Symbol 304)(Nickel Content) |
- |
6900 |
|
- |
| Cl. 5 , As per IS 5522-2014, Cl. 7.2 , Table 1 & 2 Grade Desig X-04-Cr-19-Ni-19 (Numeric Symbol 304)(Chromium Content) |
- |
6900 |
|
- |
| Cl. 5 , As per IS 5522-2014, Cl. 7.2 , Table 1 & 2 Grade Desig X-04-Cr-19-Ni-19 (Numeric Symbol 304)(Sulphur Content) |
- |
6900 |
|
- |
| Cl. 5 , As per IS 5522-2014, Cl. 7.2 , Table 1 & 2 Grade Desig X-04-Cr-19-Ni-19 (Numeric Symbol 304)(Phouphorous Content) |
- |
6900 |
|
- |
| Cl. 5 , As per IS 5522-2014, Cl. 7.2 , Table 1 & 2 Grade Desig X-04-Cr-19-Ni-19 (Numeric Symbol 304)(Nitrogen Content) |
- |
6900 |
|
- |
| Cl. 5 , As per IS 5522-2014, Cl. 7.2 , Table 1 & 2 Grade Desig X-07-Cr-18-Ni-9 (Numeric Symbol 302)(Carbon Content) |
- |
6900 |
|
- |
| Cl. 5 , As per IS 5522-2014, Cl. 7.2 , Table 1 & 2 Grade Desig X-07-Cr-18-Ni-9 (Numeric Symbol 302)(Silicon Content) |
- |
6900 |
|
- |
| Cl. 5 , As per IS 5522-2014, Cl. 7.2 , Table 1 & 2 Grade Desig X-07-Cr-18-Ni-9 (Numeric Symbol 302)(Manganese Content) |
- |
6900 |
|
- |
| Cl. 5 , As per IS 5522-2014, Cl. 7.2 , Table 1 & 2 Grade Desig X-07-Cr-18-Ni-9 (Numeric Symbol 302)(Nickel Content) |
- |
6900 |
|
- |
| Cl. 5 , As per IS 5522-2014, Cl. 7.2 , Table 1 & 2 Grade Desig X-07-Cr-18-Ni-9 (Numeric Symbol 302)(Chromium Content) |
- |
6900 |
|
- |
| Cl. 5 , As per IS 5522-2014, Cl. 7.2 , Table 1 & 2 Grade Desig X-07-Cr-18-Ni-9 (Numeric Symbol 302)(Sulphur Content) |
- |
6900 |
|
- |
| Cl. 5 , As per IS 5522-2014, Cl. 7.2 , Table 1 & 2 Grade Desig X-07-Cr-18-Ni-9 (Numeric Symbol 302)(Phouphorous Content) |
- |
6900 |
|
- |
| Cl. 5 , As per IS 5522-2014, Cl. 7.2 , Table 1 & 2 Grade Desig X-07-Cr-18-Ni-9 (Numeric Symbol 302)(Nitrogen Content) |
- |
6900 |
|
- |
| 6(Thickness of sheet/strip) |
- |
6900 |
|
- |
| 6(Depth of bowl) |
- |
6900 |
|
- |
| 6(Internal dimensions of the bowl) |
- |
6900 |
|
- |
| 6(Bowl locating limits) |
- |
6900 |
|
- |
| 6(Co-ordinating sizes) |
- |
6900 |
|
- |
| 7.1(Consruction and workmanship) |
- |
6900 |
|
- |
| 7.1.1(Consruction and workmanship) |
- |
6900 |
|
- |
| 7.2(Consruction and workmanship) |
- |
6900 |
|
- |
| 7.2.1(Consruction and workmanship) |
- |
6900 |
|
- |
| 7.3(Drainers) |
- |
6900 |
|
- |
| 7.4(Waste outlet) |
- |
6900 |
|
- |
| 7.5(Tap holes) |
- |
6900 |
|
- |
| 7.6(Overflows) |
- |
6900 |
|
- |
| 8(Finish) |
- |
6900 |
|
- |
| 5(MATERIALS) |
- |
6900 |
|
- |
| 6.1.1(Thickness of Sheet/Strip) |
- |
6900 |
|
- |
| 6.1.2(Thickness of Sheet/Strip) |
- |
6900 |
|
- |
| 6.2(Depth of Bowls) |
- |
6900 |
|
- |
| 6.3(Internal Dimensions of Bowls) |
- |
6900 |
|
- |
| 6.4.1(Bowl Locating Limits) |
- |
6900 |
|
- |
| 6.5(Coordinating Sizes) |
- |
6900 |
|
- |
| 7.1(CONSTRUCTION AND WORKMANSHIP) |
- |
6900 |
|
- |
| 7.1.1(CONSTRUCTION AND WORKMANSHIP) |
- |
6900 |
|
- |
| 7.2.1(CONSTRUCTION AND WORKMANSHIP) |
- |
6900 |
|
- |
| 7.3(CONSTRUCTION AND WORKMANSHIP) |
- |
6900 |
|
- |
| 7.4(Waste Outlet) |
- |
6900 |
|
- |
| 7.5(Tap Holes) |
- |
6900 |
|
- |
| 7.6(OVERFLOW) |
- |
6900 |
|
- |
| Clause no. 4(types) |
- |
6900 |
|
- |
| Caluse no. 5("Material -Austenitic stainless steel of
Grade Designation") |
- |
6900 |
|
- |
| Clause no. 6.1(Thickness of sheet) |
- |
6900 |
|
- |
| Clause no. 6.2(Depth of Bowls) |
- |
6900 |
|
- |
| Clause no. 6.3(Internal dimensions of bowls) |
- |
6900 |
|
- |
| Clause no. 6.4(Bowl Locating Limits) |
- |
6900 |
|
- |
| Clause no. 6.5, Table No. 1(Dimension of the sink) |
- |
6900 |
|
- |
| Clause no. 7(Construction and workmanship) |
- |
6900 |
|
- |
| Clause no. 8(Finish) |
- |
6900 |
|
- |
| Clause no. 9(Mark) |
- |
6900 |
|
- |
|
27 May, 2028 |
- - |
| 1331 |
EKO PRO ENGINEERS PRIVATE LIMITED (32/37) GHAZIABAD
| 8164006
| IS 15911 (2010) |
Structural steel (Ordinary Quality) - Specification |
E165, E170, E215 |
7200 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Table-1, 5.1, 8.1 & 8.2(Carbon: Relevant parts of IS 228 or any other established instrumental/chemical method) |
- |
7200 |
|
- |
| Table-1, 5.1, 8.1 & 8.2(Sulphur: Relevant parts of IS 228 or any other established instrumental/chemical method) |
- |
7200 |
|
- |
| Table-1, 5.1, 8.1 & 8.2(Phosphorous: Relevant parts of IS 228 or any other established instrumental/chemical method) |
- |
7200 |
|
- |
| Table-1, 5.1, 8.1 & 8.2(Manganese: Relevant parts of IS 228 or any other established instrumental/chemical method) |
- |
7200 |
|
- |
| Table-1, 5.1, 8.1 & 8.2(Silicon: Relevant parts of IS 228 or any other established instrumental/chemical method) |
- |
7200 |
|
- |
| Table-1, 5.1, 8.1 & 8.2(Chromium: Relevant parts of IS 228 or any other established instrumental/chemical method) |
- |
7200 |
|
- |
| Table-1, 5.1, 8.1 & 8.2(Molybdenum: Relevant parts of IS 228 or any other established instrumental/chemical method) |
- |
7200 |
|
- |
| Table-1, 5.1, 8.1 & 8.2(Vanadium: Relevant parts of IS 228 or any other established instrumental/chemical method) |
- |
7200 |
|
- |
| Table-1, 5.1, 8.1 & 8.2(Nickel: Relevant parts of IS 228 or any other established instrumental/chemical method) |
- |
7200 |
|
- |
| Table-1, 5.1, 8.1 & 8.2(Copper: Relevant parts of IS 228 or any other established instrumental/chemical method) |
- |
7200 |
|
- |
| Table-1, 5.1, 8.1 & 8.2(Aluminium: Relevant parts of IS 228 or any other established instrumental/chemical method) |
- |
7200 |
|
- |
| Table-1, 5.1, 8.1 & 8.2(Nitrogen: Relevant parts of IS 228 or any other established instrumental/chemical method) |
- |
7200 |
|
- |
| Table-1, 5.1, 8.1 & 8.2(Niobium: Relevant parts of IS 228 or any other established instrumental/chemical method) |
- |
7200 |
|
- |
| Table-1, 5.1, 8.1 & 8.2(Titanium: Relevant parts of IS 228 or any other established instrumental/chemical method) |
- |
7200 |
|
- |
| Table-1, 5.1, 8.1 & 8.2(Boron: Relevant parts of IS 228 or any other established instrumental/chemical method) |
- |
7200 |
|
- |
| 7(Freedom from defects) |
- |
7200 |
|
- |
| 5 and 10.3.1(Tensile strength. IS 1608) |
- |
7200 |
|
- |
| 5 and 10.3.1(Yield Stress. IS 1608) |
- |
7200 |
|
- |
| 5 and 10.3.1(Percentage Elongation. . IS 1608) |
- |
7200 |
|
- |
| 5 and 10.3.1(Internal Bend Diameter) |
- |
7200 |
|
- |
| 11.3( Bend Test. IS 1599) |
- |
7200 |
|
- |
| Cl 12 of IS 15911 and Table 2.1 of IS 808(Mass. IS 808) |
- |
7200 |
|
- |
| Cl 12 of IS 15911 and Table 2.1 of IS 808(Sectional Area. IS 808) |
- |
7200 |
|
- |
| Cl 12 of IS 15911 and Table 2.1 of IS 808(D) |
- |
7200 |
|
- |
| Cl 12 of IS 15911 and Table 2.1 of IS 808(B) |
- |
7200 |
|
- |
| Cl 12 of IS 15911 and Table 2.1 of IS 808(t) |
- |
7200 |
|
- |
| Cl 12 of IS 15911 and Table 2.1 of IS 808(T) |
- |
7200 |
|
- |
| Cl 12 of IS 15911 and Table 2.1 of IS 808(Flange Slop, Max α , ) |
- |
7200 |
|
- |
| Cl 12 of IS 15911 and Table 2.1 of IS 808(R1) |
- |
7200 |
|
- |
| Cl 12 of IS 15911 and Table 2.1 of IS 808(R2) |
- |
7200 |
|
- |
| Cl 12 of IS 15911 and Table 2.1 of IS 808(Ix) |
- |
7200 |
|
- |
| Cl 12 of IS 15911 and Table 2.1 of IS 808(Iy) |
- |
7200 |
|
- |
| Cl 12 of IS 15911 and Table 2.1 of IS 808(rx) |
- |
7200 |
|
- |
| Cl 12 of IS 15911 and Table 2.1 of IS 808(ry) |
- |
7200 |
|
- |
| Cl 12 of IS 15911 and Table 2.1 of IS 808(Zx) |
- |
7200 |
|
- |
| Cl 12 of IS 15911 and Table 2.1 of IS 808(Zy) |
- |
7200 |
|
- |
| Cl 12 of IS 15911 and Table 2.2 of IS 808(Mass. IS 808) |
- |
7200 |
|
- |
| Cl 12 of IS 15911 and Table 2.1 of IS 808(Sectional Area. IS 808) |
- |
7200 |
|
- |
| Cl 12 of IS 15911 and Table 2.1 of IS 808(D) |
- |
7200 |
|
- |
| Cl 12 of IS 15911 and Table 2.1 of IS 808(B) |
- |
7200 |
|
- |
| Cl 12 of IS 15911 and Table 2.1 of IS 808(t) |
- |
7200 |
|
- |
| Cl 12 of IS 15911 and Table 2.1 of IS 808(T) |
- |
7200 |
|
- |
| Cl 12 of IS 15911 and Table 2.1 of IS 808(Flange Slop, Max α , ) |
- |
7200 |
|
- |
| Cl 12 of IS 15911 and Table 2.1 of IS 808(R1) |
- |
7200 |
|
- |
| Cl 12 of IS 15911 and Table 2.1 of IS 808(R2) |
- |
7200 |
|
- |
| Cl 12 of IS 15911 and Table 2.1 of IS 808(Ix) |
- |
7200 |
|
- |
| Cl 12 of IS 15911 and Table 2.1 of IS 808(Iy) |
- |
7200 |
|
- |
| Cl 12 of IS 15911 and Table 2.1 of IS 808(rx) |
- |
7200 |
|
- |
| Cl 12 of IS 15911 and Table 2.1 of IS 808(ry) |
- |
7200 |
|
- |
| Cl 12 of IS 15911 and Table 2.1 of IS 808(Zx) |
- |
7200 |
|
- |
| Cl 12 of IS 15911 and Table 2.1 of IS 808(Zy) |
- |
7200 |
|
- |
| Cl 12 of IS 15911 and Table 3.1 of IS 808(Mass. IS 808) |
- |
7200 |
|
- |
| Cl 12 of IS 15911 and Table 3.1 of IS 808(Sectional Area. IS 808) |
- |
7200 |
|
- |
| Cl 12 of IS 15911 and Table 3.1 of IS 808(D) |
- |
7200 |
|
- |
| Cl 12 of IS 15911 and Table 3.1 of IS 808(B) |
- |
7200 |
|
- |
| Cl 12 of IS 15911 and Table 3.1 of IS 808(t) |
- |
7200 |
|
- |
| Cl 12 of IS 15911 and Table 3.1 of IS 808(T) |
- |
7200 |
|
- |
| Cl 12 of IS 15911 and Table 3.1 of IS 808(Flange Slop, Max α , ) |
- |
7200 |
|
- |
| Cl 12 of IS 15911 and Table 3.1 of IS 808(R1) |
- |
7200 |
|
- |
| Cl 12 of IS 15911 and Table 3.1 of IS 808(R2) |
- |
7200 |
|
- |
| Cl 12 of IS 15911 and Table 3.1 of IS 808(Ix) |
- |
7200 |
|
- |
| Cl 12 of IS 15911 and Table 3.1 of IS 808(Iy) |
- |
7200 |
|
- |
| Cl 12 of IS 15911 and Table 3.1 of IS 808(rx) |
- |
7200 |
|
- |
| Cl 12 of IS 15911 and Table 3.1 of IS 808(ry) |
- |
7200 |
|
- |
| Cl 12 of IS 15911 and Table 3.1 of IS 808(Zx) |
- |
7200 |
|
- |
| Cl 12 of IS 15911 and Table 3.1 of IS 808(Zy) |
- |
7200 |
|
- |
| Cl 12 of IS 15911 and Table 4.1 of IS 808(Mass. IS 808) |
- |
7200 |
|
- |
| Cl 12 of IS 15911 and Table 4.1 of IS 808(Sectional Area. IS 808) |
- |
7200 |
|
- |
| Cl 12 of IS 15911 and Table 4.1 of IS 808(D) |
- |
7200 |
|
- |
| Cl 12 of IS 15911 and Table 4.1 of IS 808(B) |
- |
7200 |
|
- |
| Cl 12 of IS 15911 and Table 4.1 of IS 808(t) |
- |
7200 |
|
- |
| Cl 12 of IS 15911 and Table 4.1 of IS 808(T) |
- |
7200 |
|
- |
| Cl 12 of IS 15911 and Table 4.1 of IS 808(Flange Slop, Max α , ) |
- |
7200 |
|
- |
| Cl 12 of IS 15911 and Table 4.1 of IS 808(R1) |
- |
7200 |
|
- |
| Cl 12 of IS 15911 and Table 4.1 of IS 808(R2) |
- |
7200 |
|
- |
| Cl 12 of IS 15911 and Table 4.1 of IS 808(Cy) |
- |
7200 |
|
- |
| Cl 12 of IS 15911 and Table 4.1 of IS 808(Ix) |
- |
7200 |
|
- |
| Cl 12 of IS 15911 and Table 4.1 of IS 808(Iy) |
- |
7200 |
|
- |
| Cl 12 of IS 15911 and Table 4.1 of IS 808(rx) |
- |
7200 |
|
- |
| Cl 12 of IS 15911 and Table 4.1 of IS 808(ry) |
- |
7200 |
|
- |
| Cl 12 of IS 15911 and Table 4.1 of IS 808(Zx) |
- |
7200 |
|
- |
| Cl 12 of IS 15911 and Table 4.1 of IS 808(Zy) |
- |
7200 |
|
- |
| Cl 12 of IS 15911 and Table 5.1 of IS 808(Mass. IS 808) |
- |
7200 |
|
- |
| Cl 12 of IS 15911 and Table 5.1 of IS 808(Sectional Area. IS 808) |
- |
7200 |
|
- |
| Cl 12 of IS 15911 and Table 5.1 of IS 808(A*B) |
- |
7200 |
|
- |
| Cl 12 of IS 15911 and Table 5.1 of IS 808(R1) |
- |
7200 |
|
- |
| Cl 12 of IS 15911 and Table 5.1 of IS 808(R2) |
- |
7200 |
|
- |
| Cl 12 of IS 15911 and Table 5.1 of IS 808(Cx) |
- |
7200 |
|
- |
| Cl 12 of IS 15911 and Table 5.1 of IS 808(Cy) |
- |
7200 |
|
- |
| Cl 12 of IS 15911 and Table 5.1 of IS 808(Ix) |
- |
7200 |
|
- |
| Cl 12 of IS 15911 and Table 5.1 of IS 808(Iy) |
- |
7200 |
|
- |
| Cl 12 of IS 15911 and Table 5.1 of IS 808(Ia( Max )) |
- |
7200 |
|
- |
| Cl 12 of IS 15911 and Table 5.1 of IS 808(Iv( Max )) |
- |
7200 |
|
- |
| Cl 12 of IS 15911 and Table 5.1 of IS 808(rx) |
- |
7200 |
|
- |
| Cl 12 of IS 15911 and Table 5.1 of IS 808(ry) |
- |
7200 |
|
- |
| Cl 12 of IS 15911 and Table 5.1 of IS 808(ru( Max )) |
- |
7200 |
|
- |
| Cl 12 of IS 15911 and Table 5.1 of IS 808(rv( Min )) |
- |
7200 |
|
- |
| Cl 12 of IS 15911 and Table 5.1 of IS 808(Zx) |
- |
7200 |
|
- |
| Cl 12 of IS 15911 and Table 5.1 of IS 808(Zy ) |
- |
7200 |
|
- |
| Cl 12 of IS 15911 and Table 6.1 of IS 808(Mass. IS 808) |
- |
7200 |
|
- |
| Cl 12 of IS 15911 and Table 6.1 of IS 808(Sectional Area. IS 808) |
- |
7200 |
|
- |
| Cl 12 of IS 15911 and Table 6.1 of IS 808(A*B) |
- |
7200 |
|
- |
| Cl 12 of IS 15911 and Table 6.1 of IS 808(R1) |
- |
7200 |
|
- |
| Cl 12 of IS 15911 and Table 6.1 of IS 808(R2) |
- |
7200 |
|
- |
| Cl 12 of IS 15911 and Table 6.1 of IS 808(Cx) |
- |
7200 |
|
- |
| Cl 12 of IS 15911 and Table 6.1 of IS 808(Cy) |
- |
7200 |
|
- |
| Cl 12 of IS 15911 and Table 6.1 of IS 808(Tanα) |
- |
7200 |
|
- |
| Cl 12 of IS 15911 and Table 6.1 of IS 808(Ix) |
- |
7200 |
|
- |
| Cl 12 of IS 15911 and Table 6.1 of IS 808(Iy) |
- |
7200 |
|
- |
| Cl 12 of IS 15911 and Table 6.1 of IS 808(Ia( Max )) |
- |
7200 |
|
- |
| Cl 12 of IS 15911 and Table 6.1 of IS 808(Iv( Max )) |
- |
7200 |
|
- |
| Cl 12 of IS 15911 and Table 6.1 of IS 808(rx) |
- |
7200 |
|
- |
| Cl 12 of IS 15911 and Table 6.1 of IS 808(ry) |
- |
7200 |
|
- |
| Cl 12 of IS 15911 and Table 6.1 of IS 808(ru( Max )) |
- |
7200 |
|
- |
| Cl 12 of IS 15911 and Table 6.1 of IS 808(rv( Min )) |
- |
7200 |
|
- |
| Cl 12 of IS 15911 and Table 6.1 of IS 808(Zx) |
- |
7200 |
|
- |
| Cl 12 of IS 15911 and Table 6.1 of IS 808(Zy ) |
- |
7200 |
|
- |
| Cl 12 of IS 15911 and Table 6.2 of IS 808(Mass. IS 808) |
- |
7200 |
|
- |
| Cl 12 of IS 15911 and Table 6.2 of IS 808(Sectional Area. IS 808) |
- |
7200 |
|
- |
| Cl 12 of IS 15911 and Table 6.2 of IS 808(A*B) |
- |
7200 |
|
- |
| Cl 12 of IS 15911 and Table 6.2 of IS 808(R1) |
- |
7200 |
|
- |
| Cl 12 of IS 15911 and Table 6.2 of IS 808(R2) |
- |
7200 |
|
- |
| Cl 12 of IS 15911 and Table 6.2 of IS 808(Cx) |
- |
7200 |
|
- |
| Cl 12 of IS 15911 and Table 6.2 of IS 808(Cy) |
- |
7200 |
|
- |
| Cl 12 of IS 15911 and Table 6.2 of IS 808(Tanα) |
- |
7200 |
|
- |
| Cl 12 of IS 15911 and Table 6.2 of IS 808(Ix) |
- |
7200 |
|
- |
| Cl 12 of IS 15911 and Table 6.2 of IS 808(Iy) |
- |
7200 |
|
- |
| Cl 12 of IS 15911 and Table 6.2 of IS 808(Ia( Max )) |
- |
7200 |
|
- |
| Cl 12 of IS 15911 and Table 6.2 of IS 808(Iv( Max )) |
- |
7200 |
|
- |
| Cl 12 of IS 15911 and Table 6.2 of IS 808(rx) |
- |
7200 |
|
- |
| Cl 12 of IS 15911 and Table 6.2 of IS 808(ry) |
- |
7200 |
|
- |
| Cl 12 of IS 15911 and Table 6.2 of IS 808(ru( Max )) |
- |
7200 |
|
- |
| Cl 12 of IS 15911 and Table 6.2 of IS 808(rv( Min )) |
- |
7200 |
|
- |
| Cl 12 of IS 15911 and Table 6.2 of IS 808(Zx) |
- |
7200 |
|
- |
| Cl 12 of IS 15911 and Table 6.2 of IS 808(Zy ) |
- |
7200 |
|
- |
| Cl 12 of IS 15911 and Table 1 of IS 1173(Clauses 3.1 , 5.1 and Table 1 of IS 1173) |
- |
7200 |
|
- |
| Cl 12 of IS 15911 and Table 1 of IS 1252(Clauses 4.1 , 6.1 and Table 1 of IS 1252) |
- |
7200 |
|
- |
| Cl 12 of IS 15911 and Table 2 of IS 1730(Clauses 4.1 , 4.2 and Table 1 of IS 1730) |
- |
7200 |
|
- |
| Cl 12 of IS 15911 and Table 2 of IS 1730(Clauses 4.2 and Table 1 of IS 1730) |
- |
7200 |
|
- |
| Cl 12 of IS 15911 and Table 3 of IS 1730(Clauses 4.3 and Table 1 of IS 1730) |
- |
7200 |
|
- |
| Cl 12 of IS 15911 and Table 4 of IS 1730(Clauses 5.1 and Table 1 of IS 1730) |
- |
7200 |
|
- |
| Cl 12 of IS 15911 and Table 5 of IS 1730(Clauses 5.2 and Table 1 of IS 1730) |
- |
7200 |
|
- |
| Cl 12 of IS 15911 and Table 6 of IS 1730(Clauses 6.1 and Table 1 of IS 1730) |
- |
7200 |
|
- |
| Cl 12 of IS 15911 and Table 7 of IS 1730(Clauses 6.2 and Table 1 of IS 1730) |
- |
7200 |
|
- |
| Cl 12 of IS 15911 and Table 8 of IS 1730(Clauses 7.1, 7.2 and Table 1 of IS 1730) |
- |
7200 |
|
- |
| Cl 12 of IS 15911 and Table 9 of IS 1730(Clauses 7.2 and Table 1 of IS 1730) |
- |
7200 |
|
- |
| Cl 12 of IS 15911 and Table 1 of IS 1732(Clauses 3.1, 4.1,4.1.1 and Table 1 of IS 1732) |
- |
7200 |
|
- |
| Cl 12 of IS 15911 and Table 2 of IS 1732(Clauses 3.1, 4.1,4.1.1 and Table 1 of IS 1732) |
- |
7200 |
|
- |
| Cl 12 of IS 15911 and Table 1 of IS 1863(Clauses 4.1, 5.5 and Table 1 of IS 1863) |
- |
7200 |
|
- |
| Cl 12 of IS 15911 and Table 2 of IS 1863(Clauses 5.1 and Table 2 of IS 1863) |
- |
7200 |
|
- |
| Cl 12 of IS 15911 and Table 3 of IS 1863(Clauses 5.2 and Table 2 of IS 1863) |
- |
7200 |
|
- |
| Cl 12 of IS 15911 and Table 1 of IS 3954(Clauses 4, 6.1 and Table 2 of IS 3954) |
- |
7200 |
|
- |
| 13(Tolerances) |
- |
7200 |
|
- |
| 17(Marking) |
- |
7200 |
|
- |
|
27 May, 2028 |
- - |
| 1332 |
EKO PRO ENGINEERS PRIVATE LIMITED (32/37) GHAZIABAD
| 8164006
| IS 10748 (2004) |
Hot - Rolled steel strip for welded tubes and pipes - Specification (Second Revision) |
G1/ G2/ G3/ G4/ G5/ G6 |
5900 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl 8 & Table 3(UTM) |
- |
5900 |
|
- |
| Cl 9(Press) |
- |
5900 |
|
- |
| Cl 11(Workmanship) |
- |
5900 |
|
- |
| Cl 12 & 13(Length, Width & Thickness) |
- |
5900 |
|
- |
| Cl 8 & Table 3(UTM) |
- |
5900 |
|
- |
| Cl 9(Press) |
- |
5900 |
|
- |
| Cl 11(Workmanship) |
- |
5900 |
|
- |
| Cl 12 & 13(Length, Width & Thickness) |
- |
5900 |
|
- |
| Cl 8 & Table 3(UTM) |
- |
5900 |
|
- |
| Cl 9(Press) |
- |
5900 |
|
- |
| Cl 11(Workmanship) |
- |
5900 |
|
- |
| Cl 12 & 13(Length, Width & Thickness) |
- |
5900 |
|
- |
| 7.1(Carbon %) |
- |
5900 |
|
- |
| 7.1(Manganese %) |
- |
5900 |
|
- |
| 7.1(Phosphorus %) |
- |
5900 |
|
- |
| 7.1(Sulphur %) |
- |
5900 |
|
- |
| 7.1(Silicon %) |
- |
5900 |
|
- |
| 7.1( Copper %) |
- |
5900 |
|
- |
| 7.1( Aluminium %) |
- |
5900 |
|
- |
| 7.1( Nb) |
- |
5900 |
|
- |
| 7.1(V) |
- |
5900 |
|
- |
| 7.1( Ti) |
- |
5900 |
|
- |
| 7.1(Cr) |
- |
5900 |
|
- |
| 7.1(Mo) |
- |
5900 |
|
- |
| 7.1(Ni) |
- |
5900 |
|
- |
| 7.1( Nitrogen%) |
- |
5900 |
|
- |
| 7.1(CE) |
- |
5900 |
|
- |
| 7.1(Carbon %) |
- |
5900 |
|
- |
| 7.1(Manganese %) |
- |
5900 |
|
- |
| 7.1(Phosphorus %) |
- |
5900 |
|
- |
| 7.1(Sulphur %) |
- |
5900 |
|
- |
| 7.1(Silicon %) |
- |
5900 |
|
- |
| 7.1( Copper %) |
- |
5900 |
|
- |
| 7.1( Aluminium %) |
- |
5900 |
|
- |
| 7.1( Nb) |
- |
5900 |
|
- |
| 7.1(V) |
- |
5900 |
|
- |
| 7.1( Ti) |
- |
5900 |
|
- |
| 7.1(Cr) |
- |
5900 |
|
- |
| 7.1(Mo) |
- |
5900 |
|
- |
| 7.1(Ni) |
- |
5900 |
|
- |
| 7.1( Nitrogen%) |
- |
5900 |
|
- |
| 7.1(CE) |
- |
5900 |
|
- |
| 7.1(Carbon %) |
- |
5900 |
|
- |
| 7.1(Manganese %) |
- |
5900 |
|
- |
| 7.1(Phosphorus %) |
- |
5900 |
|
- |
| 7.1(Sulphur %) |
- |
5900 |
|
- |
| 7.1(Silicon %) |
- |
5900 |
|
- |
| 7.1( Copper %) |
- |
5900 |
|
- |
| 7.1( Aluminium %) |
- |
5900 |
|
- |
| 7.1( Nb) |
- |
5900 |
|
- |
| 7.1(V) |
- |
5900 |
|
- |
| 7.1( Ti) |
- |
5900 |
|
- |
| 7.1(Cr) |
- |
5900 |
|
- |
| 7.1(Mo) |
- |
5900 |
|
- |
| 7.1(Ni) |
- |
5900 |
|
- |
| 7.1( Nitrogen%) |
- |
5900 |
|
- |
| 7.1(CE) |
- |
5900 |
|
- |
| Table 1 ( Clauses 7.1 ,7.2 )(TITANIUM) |
- |
5900 |
|
- |
| Table 1 ( Clauses 7.1 ,7.2 )(VANADIUM) |
- |
5900 |
|
- |
| Table 1 ( Clauses 7.1 ,7.2 )(NIOBIUM) |
- |
5900 |
|
- |
| Table 1 ( Clauses 7.1 ,7.2 )(CARBON EQUIVELENT ) |
- |
5900 |
|
- |
| Table 1 ( Clauses 7.1 ,7.2 )(Molybdenum) |
- |
5900 |
|
- |
| Table 1 ( Clauses 7.1 ,7.2 )(Chromium) |
- |
5900 |
|
- |
| Table 1 ( Clauses 7.1 ,7.2 )(Nickel) |
- |
5900 |
|
- |
| Table 1 ( Clauses 7.1 ,7.2 )( ALUMINIUM) |
- |
5900 |
|
- |
| Table 1 ( Clauses 7.1 ,7.2 )(SILICON) |
- |
5900 |
|
- |
| Table 1 ( Clauses 7.1 ,7.2 )(NITROGEN) |
- |
5900 |
|
- |
| Table 1 ( Clauses 7.1 ,7.2 )(MANGANESE) |
- |
5900 |
|
- |
| Table 1 ( Clauses 7.1 ,7.2 )(PHOSPHURS) |
- |
5900 |
|
- |
| Table 1 ( Clauses 7.1 ,7.2 )(SULPHUR) |
- |
5900 |
|
- |
| Table 1 ( Clauses 7.1 ,7.2 )( CARBON) |
- |
5900 |
|
- |
| Cl. 14(Weight) |
- |
5900 |
|
- |
| Cl. 12, 13(Camber) |
- |
5900 |
|
- |
| Cl. 12, 13(Thickness) |
- |
5900 |
|
- |
| Cl. 8, Table 3(Elongation) |
- |
5900 |
|
- |
| Cl. 8, Table 3(Yield Stress) |
- |
5900 |
|
- |
| Cl 12 & 13(Length, Width & Thickness) |
- |
5900 |
|
- |
| Cl 11(Workmanship) |
- |
5900 |
|
- |
| Cl 9(Press) |
- |
5900 |
|
- |
| Cl 8 & Table 3(UTM) |
- |
5900 |
|
- |
| Cl 8 & Table 3(UTM) |
- |
5900 |
|
- |
| Cl 9(Press) |
- |
5900 |
|
- |
| Cl 11(Workmanship) |
- |
5900 |
|
- |
| Cl 12 & 13(Length, Width & Thickness) |
- |
5900 |
|
- |
| 7.0 (7)(Micro Alloying elements - IS:8811) |
- |
5900 |
|
- |
| 8.0 (1)(Tensile Strength-IS:1608(P1)) |
- |
5900 |
|
- |
| 8.0 (2)(Yield Strength-IS:1608(P1)) |
- |
5900 |
|
- |
| 8.0 (3)(Elongation on 5.65 SoA GL-IS:1608(P1)) |
- |
5900 |
|
- |
| 12 (1)(Width - SOP MT-23) |
- |
5900 |
|
- |
| 12 (2)(Thickness- SOP MT-23) |
- |
5900 |
|
- |
| 12 (3)(Mass of Strip- SOP MT-23) |
- |
5900 |
|
- |
| 15.0 & 15.1(Coil edges - IS:10748) |
- |
5900 |
|
- |
| 15.0 & 15.2(Surface finish - IS:10748) |
- |
5900 |
|
- |
| 15.0 & 15.5(Telescopicity - IS:10748) |
- |
5900 |
|
- |
| 15(Condition of Coil) |
- |
5900 |
|
- |
| 16(Marking) |
- |
5900 |
|
- |
| 3.4(Vehicle Fuel System) |
- |
5900 |
|
- |
| 9(Protective Treatment) |
- |
5900 |
|
- |
| Table 1 ( Clauses 7.1 ,7.2 )(Tungsten (W)) |
- |
5900 |
|
- |
| Table 1 ( Clauses 7.1 ,7.2 )(Boron (B)) |
- |
5900 |
|
- |
|
27 May, 2028 |
- - |
| 1333 |
URS PRODUCTS AND TESTING PVT. LTD. (A29), NOIDA
| 8168906
| IS 16046 : Part 2 (2018) |
Secondary Cells and Batteries Containing Alkaline or Other Non-Acid Electrolytes ” Safety Requirements for Portable Sealed Secondary Cells and for Batteries Made from Them for Use in Portable Applications Part 2 Lithium Systems ( Second Revision ) |
- |
45000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4(Parameter Measurement Tolerances) |
- |
1000 |
|
- |
| 5(General Safety Considerations) |
- |
1000 |
|
- |
| 5.1(General) |
- |
1000 |
|
- |
| 5.2(Insulation and Wiring) |
- |
2500 |
|
- |
| 5.3(Venting) |
- |
1000 |
|
- |
| 5.4(Temperature, Voltage and Current Management) |
- |
1000 |
|
- |
| 5.5(Terminal Contacts) |
- |
1500 |
|
- |
| 5.6(Assembly of Cells into batteries) |
- |
1000 |
|
- |
| 5.7(Quality Plan) |
- |
1000 |
|
- |
| 5.8(Battery Safety Components) |
- |
1000 |
|
- |
| 6(Type Test and Sample Size) |
- |
1000 |
|
- |
| 7(Specific requirements and tests) |
- |
1000 |
|
- |
| 7.1(Charging procedure for test purposes) |
- |
5000 |
|
- |
| 7.2(Intended Use) |
- |
5000 |
|
- |
| 7.3(Reasonably foreseeable misuse) |
- |
2000 |
|
- |
| 8(Information for safety) |
- |
1000 |
|
- |
| 8.1(General) |
- |
1000 |
|
- |
| 8.2(Small Cell and battery safety information) |
- |
1000 |
|
- |
| 9(Marking) |
- |
1000 |
|
- |
| 9.1(Cell Marking) |
- |
1000 |
|
- |
| 9.2(Battery Marking) |
- |
1000 |
|
- |
| 9.3(Caution for ingestion of small cells and batteries) |
- |
1000 |
|
- |
| 9.4(Other information) |
- |
1000 |
|
- |
| 10(Packaging) |
- |
1000 |
|
- |
| clause 7.3.1 of IS 16047: Part 3(Discharge performance at 20 °C (rated capacity)) |
- |
30000 |
|
- |
|
- |
- included w.e.f 01.04.2026 |
| 1334 |
Stellar Test House, Noida
| 8171606
| IS 302 : PART 1 (Thermal Storage Room Heaters) |
Thermal Storage Room Heaters |
- |
30000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 6(Classifications) |
- |
500 |
|
- |
| 5(General conditions for tests) |
- |
500 |
|
- |
| 4(General Requirement) |
- |
500 |
|
- |
| 11.8(Temperature rise) |
- |
1000 |
|
- |
| 11.7(Duration corresponding) |
- |
1000 |
|
- |
| 11.6(Combined appliances) |
- |
1000 |
|
- |
| 11.5(Motor-operated appliances) |
- |
1000 |
|
- |
| 11.4(Heating appliances) |
- |
1000 |
|
- |
| 8.1.5(Live parts of built-in appliances) |
- |
1000 |
|
- |
| 18(Endurance) |
- |
1000 |
|
- |
| 17(Overload protection of transformers and associated circuits) |
- |
1000 |
|
- |
| 16(Leakage current and electric strength) |
- |
1000 |
|
- |
| 4(General requirement) |
- |
500 |
|
- |
| 32(Radiation Toxicity and Similar Hazards) |
- |
1000 |
|
- |
| 31(Resistance to Rusting) |
- |
1000 |
|
- |
| 30.2(Needle Flame Test) |
- |
1000 |
|
- |
| 30.2(Glow Wire Test) |
- |
1000 |
|
- |
| 30.1(Ball pressure test) |
- |
1000 |
|
- |
| 29(clearance, creepage distances and solid insulation) |
- |
1000 |
|
- |
| 28(Screw test and connections) |
- |
1000 |
|
- |
| 27(Provision for earthing) |
- |
1000 |
|
- |
| 26(Terminals for external conductors) |
- |
1000 |
|
- |
| 25(Supply connection and external flexible cords) |
- |
1000 |
|
- |
| 24(Components) |
- |
1000 |
|
- |
| 23(General) |
- |
1000 |
|
- |
| 22(Construction verification related test) |
- |
1000 |
|
- |
| 21(Mechanical Strength Test) |
- |
1000 |
|
- |
| 20(Stability test) |
- |
1000 |
|
- |
| 19(Abnormal Operation) |
- |
1000 |
|
- |
| 18(Endurance Test requirements and tests) |
- |
1000 |
|
- |
| 17(Over Load Protection of Transformers and associated circuits) |
- |
1000 |
|
- |
| 16.3(Electric Strength (after clause 15 and 16.2)) |
- |
1000 |
|
- |
| 16.2(Leakage Current (after Clause 15)) |
- |
1000 |
|
- |
| 16.1(General) |
- |
1000 |
|
- |
| 16.0(General) |
- |
1000 |
|
- |
| 15.3(Humidity Test) |
- |
1000 |
|
- |
| 15.2(Spillage Test) |
- |
1000 |
|
- |
| 15.1(Ingress Protection test other than IPX0 (IP test)) |
- |
1000 |
|
- |
| 15.0(General) |
- |
1000 |
|
- |
| 14(Transient Over Voltages) |
- |
1000 |
|
- |
| 13.3(Electric Strength at operating temperature) |
- |
1000 |
|
- |
| 13.2(Leakage current at operating temperature) |
- |
1000 |
|
- |
| 13.1(General) |
- |
1000 |
|
- |
| 11.3(Heating) |
- |
1000 |
|
- |
| 11.2(General) |
- |
1000 |
|
- |
| 11.1(General) |
- |
1000 |
|
- |
| 10.2(Current input) |
- |
1000 |
|
- |
| 10.1(Power input) |
- |
1000 |
|
- |
| 9(Starting of motor operation test requirements and tests) |
- |
1000 |
|
- |
| 8.1.4(Protection against live parts against protective impedance) |
- |
1000 |
|
- |
| 8.1.3(Protection against live parts in visible glowing heating elements) |
- |
1000 |
|
- |
| 8.1.2(Protection against live parts in openings) |
- |
1000 |
|
- |
| 8.1.1(Protection against live parts in all positions) |
- |
1000 |
|
- |
| 7(Marking and instructions) |
- |
500 |
|
- |
|
26 Sep, 2028 |
- Included w.e.f. 18.06.2026
19.11.4.7 (Harmonics)
19.11.4.6 (Class 3 Voltage dips and interruptions)
19.11.4.5 (Immunity to conducted discharges)
19.11.4.4 (Surge immunity test)
19.11.4.3 (Fast transient bursts)
19.11.4.1 (Electrostatic discharges)" |
| 1335 |
Nemko India (Test Lab) Pvt. Ltd., Faridabad
| 8138426
| IS 302 : Part 2 : Sec 8 (2024) |
Household and Similar Electrical Appliances âSafety Part 2 Particular Requirements Section 8 Shavers, Hair Clippers and Similar Appliances (First Revision) |
- |
240000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 7(Marking and instructions) |
- |
2000 |
|
10% (Discount offered to BIS) |
| 8(Protection against access to live parts) |
- |
4000 |
|
10% (Discount offered to BIS) |
| 10(Power input and current) |
- |
5000 |
|
10% (Discount offered to BIS) |
| 11(Heating) |
- |
5000 |
|
10% (Discount offered to BIS) |
| 12(Charging of metal-ion batteries) |
- |
2000 |
|
10% (Discount offered to BIS |
| 13.1 &13.2(Leakage current test) |
- |
2000 |
|
10% (Discount offered to BIS |
| 13.1 &13.3(Electric strength test) |
- |
0 |
|
-- |
| 14(Transient overvoltages) |
- |
2000 |
|
10% (Discount offered to BIS |
| 15(Moisture resistance) |
- |
10000 |
|
10% (Discount offered to BIS |
| 15.3(Moisture resistance) |
- |
0 |
|
-- |
| 16.1 &16.2(Leakage current test) |
- |
3000 |
|
10% (Discount offered to BIS) |
| 16.1 & 16.3(Electric strength test) |
- |
0 |
|
-- |
| 17(Overload protection of transformers and associated circuits) |
- |
2000 |
|
10% (Discount offered to BIS) |
| 19.1 to 19.13, Table No. - 9(Abnormal operation) |
- |
9000 |
|
10% (Discount offered to BIS) |
| 19.101(Abnormal operation) |
- |
0 |
|
-- |
| 20.1(Stability and mechanical hazards) |
- |
2000 |
|
10% (Discount offered to BIS) |
| 20.2(Stability and mechanical hazards) |
- |
0 |
|
-- |
| 21(Mechanical strength) |
- |
2000 |
|
10% (Discount offered to BIS) |
| 21.101(Mechanical strength) |
- |
0 |
|
-- |
| 21.102(Mechanical strength) |
- |
0 |
|
-- |
| 21.103(Mechanical strength) |
- |
0 |
|
-- |
| 23(Internal wiring) |
- |
2000 |
|
10% (Discount offered to BIS) |
| 25("Supply connection and
external flexible cords") |
- |
2000 |
|
10% (Discount offered to BIS) |
| 26("Terminals for external
conductors") |
- |
2000 |
|
10% (Discount offered to BIS) |
| 27(Provision for earthing) |
- |
4000 |
|
10% (Discount offered to BIS) |
| 28(Screws and connections) |
- |
2000 |
|
10% (Discount offered to BIS) |
| 29("Clearances, creepage
distances and solid insulation") |
- |
3000 |
|
10% (Discount offered to BIS) |
| 30(Resistance to heat and fire) |
- |
8000 |
|
10% (Discount offered to BIS) |
| 31(Resistance to rusting) |
- |
2000 |
|
10% (Discount offered to BIS) |
| 19.11.4.1(Electrostatic discharges) |
- |
20000 |
|
10% (Discount offered to BIS) |
| 19.11.4.2(Radiated fields) |
- |
40000 |
|
10% (Discount offered to BIS) |
| 19.11.4.3(Fast transient bursts) |
- |
15000 |
|
10% (Discount offered to BIS) |
| 19.11.4.4(Surge immunity test) |
- |
15000 |
|
10% (Discount offered to BIS) |
| 19.11.4.5(Immunity to conducted discharges) |
- |
20000 |
|
10% (Discount offered to BIS) |
| 19.11.4.6(Class 3 Voltage dips and interruptions) |
- |
20000 |
|
10% (Discount offered to BIS) |
| 19.11.4.7(Harmonics) |
- |
40000 |
|
10% (Discount offered to BIS) |
| 22(Construction) |
- |
4000 |
|
10% (Discount offered to BIS) |
| 22.101(Construction) |
- |
0 |
|
-- |
| 22.102(Construction) |
- |
0 |
|
-- |
| 22.103(Construction) |
- |
0 |
|
-- |
| 7(Marking and instructions) |
- |
0 |
|
-- |
| 8(Protection against access to live parts) |
- |
0 |
|
-- |
| 10(Power input and current) |
- |
0 |
|
-- |
| 11(Heating) |
- |
0 |
|
-- |
| 12(Charging of metal-ion batteries) |
- |
0 |
|
-- |
| 13.1 &13.2(Leakage current test) |
- |
0 |
|
-- |
| 13.1 &13.3(Electric strength test) |
- |
0 |
|
-- |
| 14(Transient overvoltages) |
- |
0 |
|
-- |
| 15(Moisture resistance) |
- |
0 |
|
-- |
| 15.3(Moisture resistance) |
- |
0 |
|
-- |
| 16.1 &16.2(Leakage current test) |
- |
0 |
|
-- |
| 16.1 & 16.3(Electric strength test) |
- |
0 |
|
-- |
| 17(Overload protection of transformers and associated circuits) |
- |
0 |
|
-- |
| 19.1 to 19.13, Table No. - 9(Abnormal operation) |
- |
0 |
|
-- |
| 19.101(Abnormal operation) |
- |
0 |
|
-- |
| 20.1(Stability and mechanical hazards) |
- |
0 |
|
-- |
| 20.2(Stability and mechanical hazards) |
- |
0 |
|
-- |
| 21(Mechanical strength) |
- |
0 |
|
-- |
| 21.101(Mechanical strength) |
- |
0 |
|
-- |
| 21.102(Mechanical strength) |
- |
0 |
|
-- |
| 21.103(Mechanical strength) |
- |
0 |
|
-- |
| 23(Internal wiring) |
- |
0 |
|
-- |
| 25("Supply connection and
external flexible cords") |
- |
0 |
|
-- |
| 26("Terminals for external
conductors") |
- |
0 |
|
-- |
| 27(Provision for earthing) |
- |
0 |
|
-- |
| 28(Screws and connections) |
- |
0 |
|
-- |
| 29("Clearances, creepage
distances and solid insulation") |
- |
0 |
|
-- |
| 30(Resistance to heat and fire) |
- |
0 |
|
-- |
| 31(Resistance to rusting) |
- |
0 |
|
-- |
| 19.11.4.1(Electrostatic discharges) |
- |
0 |
|
-- |
| 19.11.4.2(Radiated fields) |
- |
0 |
|
-- |
| 19.11.4.3(Fast transient bursts) |
- |
0 |
|
-- |
| 19.11.4.4(Surge immunity test) |
- |
0 |
|
-- |
| 19.11.4.5(Immunity to conducted discharges) |
- |
0 |
|
-- |
| 19.11.4.6(Class 3 Voltage dips and interruptions) |
- |
0 |
|
-- |
| 19.11.4.7(Harmonics) |
- |
0 |
|
-- |
| 22(Construction) |
- |
0 |
|
-- |
| 22.101(Construction) |
- |
0 |
|
-- |
| 22.102(Construction) |
- |
0 |
|
-- |
| 22.103(Construction) |
- |
0 |
|
-- |
|
31 Dec, 2029 |
- Included w.e.f 08.04.2026
Exclusion: 24 (Components), 32 ("Radiation, toxicity and similar hazards"), 22.16 Automatic cord reels test, 22.32 Oxygen bomb based test |
| 1336 |
QUALITY INTERNATIONAL RESEARCH & LABORATORIES PRIVATE LIMITED
| 5197006
| IS 1079 (2017) |
Hot rolled carbon steel sheet, plate and strip - Specification (Seventh Revision) |
Hot Rolled Carbon Steel Sheet, Plate and Strip |
8000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl 8(UTM) |
- |
2500 |
|
- |
| Cl 9(Press) |
- |
500 |
|
- |
| Cl 10(Die Press) |
- |
500 |
|
- |
| Cl 12(Workmanship) |
- |
500 |
|
- |
| Cl 13(Length, Width & Thickness) |
- |
500 |
|
- |
| Cl 8(UTM) |
- |
2500 |
|
- |
| Cl 9(Press) |
- |
500 |
|
- |
| Cl 10(Die Press) |
- |
500 |
|
- |
| Cl 12(Workmanship) |
- |
500 |
|
- |
| Cl 13(Length, Width & Thickness) |
- |
500 |
|
- |
| Cl 8(UTM) |
- |
2500 |
|
- |
| Cl 9(Press) |
- |
500 |
|
- |
| Cl 10(Die Press) |
- |
500 |
|
- |
| Cl 12(Workmanship) |
- |
500 |
|
- |
| Cl 13(Length, Width & Thickness) |
- |
500 |
|
- |
| 6.1(Carbon %) |
- |
500 |
|
- |
| 6.1(Manganese %) |
- |
500 |
|
- |
| 6.1(Phosphorus %) |
- |
500 |
|
- |
| 6.1(Sulphur %) |
- |
500 |
|
- |
| 6.1(Silicon %) |
- |
500 |
|
- |
| 6.1( Copper %) |
- |
500 |
|
- |
| 6.1( Aluminium %) |
- |
500 |
|
- |
| 6.1( Nb) |
- |
500 |
|
- |
| 6.1(V) |
- |
500 |
|
- |
| 6.1( Ti) |
- |
500 |
|
- |
| 6.1(Cr) |
- |
500 |
|
- |
| 6.1(Mo) |
- |
500 |
|
- |
| 6.1(Ni) |
- |
500 |
|
- |
| 6.1( Nitrogen%) |
- |
2500 |
|
- |
| 6.1(Microalloying) |
- |
2500 |
|
- |
| 6.1(Carbon %) |
- |
500 |
|
- |
| 6.1(Manganese %) |
- |
500 |
|
- |
| 6.1(Phosphorus %) |
- |
500 |
|
- |
| 6.1(Sulphur %) |
- |
500 |
|
- |
| 6.1(Silicon %) |
- |
500 |
|
- |
| 6.1( Copper %) |
- |
500 |
|
- |
| 6.1( Aluminium %) |
- |
500 |
|
- |
| 6.1( Nb) |
- |
500 |
|
- |
| 6.1(V) |
- |
500 |
|
- |
| 6.1( Ti) |
- |
500 |
|
- |
| 6.1(Cr) |
- |
500 |
|
- |
| 6.1(Mo) |
- |
500 |
|
- |
| 6.1(Ni) |
- |
500 |
|
- |
| 6.1( Nitrogen%) |
- |
2500 |
|
- |
| 6.1(Microalloying) |
- |
2500 |
|
- |
| 6.1(Carbon %) |
- |
500 |
|
- |
| 6.1(Manganese %) |
- |
500 |
|
- |
| 6.1(Phosphorus %) |
- |
500 |
|
- |
| 6.1(Sulphur %) |
- |
500 |
|
- |
| 6.1(Silicon %) |
- |
500 |
|
- |
| 6.1( Copper %) |
- |
500 |
|
- |
| 6.1( Aluminium %) |
- |
500 |
|
- |
| 6.1( Nb) |
- |
500 |
|
- |
| 6.1(V) |
- |
500 |
|
- |
| 6.1( Ti) |
- |
500 |
|
- |
| 6.1(Cr) |
- |
500 |
|
- |
| 6.1(Mo) |
- |
500 |
|
- |
| 6.1(Ni) |
- |
500 |
|
- |
| 6.1( Nitrogen%) |
- |
2500 |
|
- |
| 6.1(Microalloying) |
- |
2500 |
|
- |
| Cl.13(Out of square) |
- |
500 |
|
- |
| Cl.13(Flatness) |
- |
500 |
|
- |
| Cl.13(Camber) |
- |
500 |
|
- |
| Cl.13(Width) |
- |
500 |
|
- |
| Cl.13(Thickness) |
- |
500 |
|
- |
| Cl. 8.3, Cl. 8.3.1
Table 5 and Table 6(Percentage Elongation After Fracture at 5.65√A Gauge length) |
- |
500 |
|
- |
| Cl. 8.3, Cl. 8.3.1
Table 5 and Table 6(Percentage Elongation After Fracture at 80 mm Gauge length) |
- |
500 |
|
- |
| Cl. 8.3, Cl. 8.3.1
Table 5 and Table 6(Percentage Elongation After Fracture at 50 mm Gauge length) |
- |
500 |
|
- |
| Cl. 8.3, Cl. 8.3.1
Table 6(0.2% Proof Stress/Yield Stress) |
- |
500 |
|
- |
| Cl 13(Length, Width & Thickness) |
- |
500 |
|
- |
| Cl 12(Workmanship) |
- |
500 |
|
- |
| Cl 10(Die Press) |
- |
500 |
|
- |
| Cl 9(Press) |
- |
500 |
|
- |
| Cl 8(UTM) |
- |
2500 |
|
- |
| 7(Material Test) |
- |
2500 |
|
- |
| 9(Bend test) |
- |
500 |
|
- |
| 14(Calculation of weight) |
- |
500 |
|
- |
| Cl 8(UTM) |
- |
2500 |
|
- |
| Cl 9(Press) |
- |
500 |
|
- |
| Cl 10(Die Press) |
- |
500 |
|
- |
| Cl 12(Workmanship) |
- |
500 |
|
- |
| Cl 13(Length, Width & Thickness) |
- |
500 |
|
- |
| 8, Table 5 & 6(Tensile Strength) |
- |
1000 |
|
- |
| 8, Table 5 & 6(Yield Strength) |
- |
1000 |
|
- |
| 8, Table 5 & 6(Elongation) |
- |
1000 |
|
- |
| Clause 10(Cuppping Test) |
- |
1000 |
|
- |
| Clause 12(Freedom from defect) |
- |
500 |
|
- |
| Clause 13(Length) |
- |
500 |
|
- |
| Clause 7, Table 3, Note 1(Any Instrumental Method/Chemical Method) |
- |
500 |
|
- |
| Clause 7, Table 3, Note 1(By Calculation) |
- |
500 |
|
- |
| 8, Table 5 & 6(Tensile Strength) |
- |
1000 |
|
- |
| 8, Table 5 & 6(Yield Strength) |
- |
1000 |
|
- |
| 8, Table 5 & 6(Elongation) |
- |
1000 |
|
- |
| Clause 10(Cuppping Test) |
- |
1000 |
|
- |
| Clause 12(Freedom from defect) |
- |
500 |
|
- |
| Clause 13(Length) |
- |
500 |
|
- |
| Clause 7, Table 3, Note 1(Boron) |
- |
500 |
|
- |
| Clause 7, Table 3, Note 1(B+Ti+Nb+V) |
- |
2000 |
|
- |
| 16(Marking and packing) |
- |
500 |
|
- |
| 8, Table 5 & 6(IS 1608 Part 1) |
- |
2500 |
|
- |
| 8, Table 5 & 6(IS 1608 Part 1) |
- |
2500 |
|
- |
| 8, Table 5 & 6(IS 1608 Part 1) |
- |
2500 |
|
- |
| Clause 10(IS 10175) |
- |
500 |
|
- |
| Clause 12(IS 1079) |
- |
1000 |
|
- |
| Clause 13(IS/ISO 16160) |
- |
500 |
|
- |
| Clause 7, Table 3, Note 1(Boron) |
- |
500 |
|
- |
| Clause 7, Table 3, Note 1(B+Ti+Nb+V) |
- |
2000 |
|
- |
| Cl. 7.1, table 3(Aluminium) |
- |
500 |
|
- |
| Cl. 7.1, table 3(Niobium) |
- |
500 |
|
- |
| Cl. 7.1, table 3(Vanadium) |
- |
500 |
|
- |
| Cl. 7.1, table 3(Titanium) |
- |
500 |
|
- |
| Cl. 7.1, table 3(Boron) |
- |
500 |
|
- |
| Cl. 7.1, table 3(Silicon) |
- |
500 |
|
- |
| Cl. 7.1, table 3(Nitrogen) |
- |
2500 |
|
- |
| Cl. 7.1, table 3(Copper) |
- |
500 |
|
- |
| Cl. 7.1, table 3(Total microalloying elements(Nb+V+Ti+B)) |
- |
2500 |
|
- |
|
- |
- Included w.e.f 16.03.2026 |
| 1337 |
Cotecna Inspection India Private Limited, Gurugram
| 8166106
| IS 17634 (2022) |
Storage Units - Specification |
- |
30000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| CLAUSE 5(DIMENSIONS) |
- |
1000 |
|
- |
| CLAUSE 6(SURFACE PERFORMANCE) |
- |
12000 |
|
- |
| CLAUSE 6.2(Fabric and Leather (Synthetic and Natural) Performance) |
- |
8000 |
|
- |
| CLAUSE 7.1(SAFETY TESTS (General)) |
- |
0 |
|
- |
| CLAUSE 7.2(Test for Non-Movable Parts) |
- |
0 |
|
- |
| CLAUSE 7.2.1(Shelves) |
- |
0 |
|
- |
| CLAUSE 7.2.1.2(Deflection of shelves) |
- |
2000 |
|
- |
| CLAUSE 7.2.2.1(Sustained load test for tops and bottoms) |
- |
2000 |
|
- |
| CLAUSE 7.2.2.2(Static load test for tops and bottoms) |
- |
2000 |
|
- |
| CLAUSE 7.2.3.1(Strength of clothes-rail supports) |
- |
2000 |
|
- |
| CLAUSE 7.2.3.2(Dislodgement of clothes rail) |
- |
2000 |
|
- |
| CLAUSE 7.2.4.2(Drop test) |
- |
2000 |
|
- |
| CLAUSE 7.2.4.3(Tests for units with castors or wheels) |
- |
2000 |
|
- |
| CLAUSE 7.3.1(Pivoted Doors) |
- |
0 |
|
- |
| CLAUSE 7.3.1.2.1(Vertical load on pivoted door) |
- |
2000 |
|
- |
| CLAUSE 7.3.1.2.2(Horizontal load on pivoted door) |
- |
2000 |
|
- |
| CLAUSE 7.3.1.3(Slam-shut test of pivoted doors) |
- |
2000 |
|
- |
| CLAUSE 7.3.1.4(Durability of pivoted doors) |
- |
5000 |
|
- |
| CLAUSE 7.3.2(Sliding Doors and Horizontal Roll-fronts) |
- |
0 |
|
- |
| CLAUSE 7.3.2.2(Slam shut/open test of sliding doors and horizontal roll-fronts) |
- |
3000 |
|
- |
| CLAUSE 7.3.2.3(Durability of sliding doors and horizontal roll-fronts) |
- |
6000 |
|
- |
| CLAUSE 7.3.3(Flaps) |
- |
0 |
|
- |
| CLAUSE 7.3.3.1(Strength of bottom-hinged flaps) |
- |
2000 |
|
- |
| CLAUSE 7.3.3.2(Durability of flaps) |
- |
4000 |
|
- |
| CLAUSE 7.3.3.3(Drop test for top-hinged flaps) |
- |
2000 |
|
- |
| CLAUSE 7.3.4(Vertical Roll-Fronts) |
- |
0 |
|
- |
| CLAUSE 7.3.4.1(Slam shut/open test of vertical roll-fronts) |
- |
3000 |
|
- |
| CLAUSE 7.3.4.2(Durability of vertical roll-fronts) |
- |
5000 |
|
- |
| CLAUSE 7.3.5(Extension Element) |
- |
0 |
|
- |
| CLAUSE 7.3.5.2(Strength of extension elements) |
- |
2000 |
|
- |
| CLAUSE 7.3.5.3(Durability of extension elements) |
- |
6000 |
|
- |
| CLAUSE 7.3.5.4(Slam shut/open test of extension element) |
- |
3000 |
|
- |
| CLAUSE 7.3.5.5(Displacement of extension element bottoms) |
- |
3000 |
|
- |
| CLAUSE 7.3.5.6(Interlock test) |
- |
2000 |
|
- |
| CLAUSE 7.3.6(Locking and Latching Mechanism Tests) |
- |
0 |
|
- |
| CLAUSE 7.3.6.2(Strength test for locking and latching mechanisms for extension elements) |
- |
2000 |
|
- |
| CLAUSE 7.3.6.3(Locking and latching mechanisms for doors, flaps and roll-fronts) |
- |
2000 |
|
- |
| CLAUSE 7.3.6.4(Durability test of locking and latching mechanisms) |
- |
5000 |
|
- |
| CLAUSE 7.3.7(Pull Force Test) |
- |
1000 |
|
- |
| CLAUSE 7.3.7(Pull Force Test) |
- |
0 |
|
- |
| CLAUSE 7.3.8(Top Load Ease Cycle Test) |
- |
5000 |
|
- |
| CLAUSE 7.3.9(Durability Test for Units with Seating Surfaces – Cyclic Impact) |
- |
5000 |
|
- |
| CLAUSE 7.3.10("Drop Test – Dynamic – for Units with
Seat Surfaces") |
- |
2000 |
|
- |
| CLAUSE 7.4.1.3(Sustained load test (overload)) |
- |
2000 |
|
- |
| CLAUSE 7.4.1.4(Dislodgement test) |
- |
2000 |
|
- |
| CLAUSE 7.5(Stability Tests) |
- |
0 |
|
- |
| CLAUSE 7.5.2.1("Units that can be adjusted to a Height of
1 000 mm or less") |
- |
2000 |
|
- |
| CLAUSE 7.5.2.2("Units that can be adjusted to a height of
more than 1 000 mm") |
- |
2000 |
|
- |
| CLAUSE 7.5.3(Opening Doors, Extension Elements and Flaps, All Storage Units Unloaded) |
- |
1000 |
|
- |
| CLAUSE 7.5.6(Vertical Force Stability Test for Storage Units) |
- |
1000 |
|
- |
| CLAUSE 7.5.7(Stability Test for Pedestals/Storage Units with Seat Surfaces) |
- |
1000 |
|
- |
| CLAUSE 7.5.8("Dynamic Stability Test for Units with
Castors") |
- |
1000 |
|
- |
| CLAUSE 7.5.9(Strength Test for Wall Attachments) |
- |
1000 |
|
- |
| Cl-6.1 (a)(Resistance to mechanical damage) |
- |
3000 |
|
- |
| Cl-6.1 (b)(Pencil hardness) |
- |
1000 |
|
- |
| Cl-6.1 (c)(Resistance to wet heat) |
- |
2000 |
|
- |
| Cl-6.1 (d)Cl-6.1 (d)(Resistance to dry heat) |
- |
2000 |
|
- |
| Cl-6.1 (e)(Resistance to marking by cold liquids) |
- |
3000 |
|
- |
| Cl-6.1 (f)(Resistance to marking by cold oils and fats
Resistance to marking by cold oils and fats) |
- |
3000 |
|
- |
| Cl-6.1 (g)(Adhesive performance) |
- |
2000 |
|
- |
| Cl-6.2 (a) 1(Breaking load) |
- |
600 |
|
- |
| Cl-6.2 (a) 2(Elongation at break) |
- |
600 |
|
- |
| Cl-6.2 (a) 3(Tear strength) |
- |
600 |
|
- |
| Cl-6.2 (a) 4(Colour fastness to light) |
- |
1000 |
|
- |
| Cl-6.2 (a) 5(Colour fastness to rubbing) |
- |
400 |
|
- |
| Cl-6.2 (a) 6(Colour fastness to perspiration) |
- |
650 |
|
- |
| Cl-6.2 (a) 7(Colour fastness to water) |
- |
500 |
|
- |
| Cl-6.2 (a) 8(Pilling resistance) |
- |
1000 |
|
- |
| Cl-6.2 (a) 9(Coating adhesion strength) |
- |
700 |
|
- |
| Cl-6.2 (a) 10(Seam slippage) |
- |
800 |
|
- |
| Cl-6.2 (a) 11(Resistance to damage by flexing) |
- |
2000 |
|
- |
| Cl-6.2 (a) 12(Abrasion resistance) |
- |
1000 |
|
- |
| Cl-6.2 (a) 13(Bursting strength) |
- |
700 |
|
- |
| Cl-6.2 (a) 14(Resistance to cold) |
- |
500 |
|
- |
| Cl-6.2 (b) 1(Tear strength) |
- |
650 |
|
- |
| Cl-6.2 (b) 2(Flexing endurance) |
- |
2000 |
|
- |
| Cl-6.2 (b) 3(Finish adhesion) |
- |
700 |
|
- |
| Cl-6.2 (b) 4(Colour fastness to artificial light) |
- |
2000 |
|
- |
| Cl-6.2 (b) 5(Colour fastness to rubbing) |
- |
1000 |
|
- |
| Cl-6.2 (b) 6(Colour fastness to water spotting) |
- |
500 |
|
- |
| Cl-6.2 (b) 7(Water vapour permeability) |
- |
600 |
|
- |
| Cl-6.2 (b) 8(Colour fastness to water) |
- |
700 |
|
- |
| Cl-7.1(General) |
- |
0 |
|
- |
| Cl-7.2.1(Shelves) |
- |
0 |
|
- |
| Cl-7.2.2(Tops and Bottoms) |
- |
0 |
|
- |
| Cl-7.2.3(Strength of Clothes Rails and their Supports) |
- |
0 |
|
- |
| Cl-7.2.4(Strength of the Structure) |
- |
2000 |
|
- |
| Cl-7.3.1(Pivoted Doors) |
- |
0 |
|
- |
| Cl-7.3.2(Sliding Doors and Horizontal Roll-fronts) |
- |
0 |
|
- |
| Cl-7.3.3(Flaps) |
- |
0 |
|
- |
| Cl-7.3.4(Vertical Roll-Fronts) |
- |
0 |
|
- |
| Cl-7.3.5(Extension Elements) |
- |
0 |
|
- |
| Cl-7.3.6(Locking and Latching Mechanism Test) |
- |
0 |
|
- |
| Cl-7.3.7(Pull Force Test) |
- |
0 |
|
- |
| Cl-7.3.8(Top Load Ease Cycle Test) |
- |
0 |
|
- |
| Cl-7.3.9(Durability Test for Units with Seating Surfaces – Cyclic Impact) |
- |
0 |
|
- |
| Cl-7.3.10(Drop Test – Dynamic – for Units with Seat Surfaces) |
- |
0 |
|
- |
| Cl-7.4.1(Units Not Supported by the Floor) |
- |
0 |
|
- |
| Cl-7.4.2(Units Supported by the Floor) |
- |
0 |
|
- |
| Cl-7.5.1(General) |
- |
0 |
|
- |
| Cl-7.5.2(Doors, Extension Elements and Flaps Closed, All Storage Units Unloaded) |
- |
0 |
|
- |
| Cl-7.5.3(Opening Doors, Extension Elements and Flaps, All Storage Units Unloaded) |
- |
0 |
|
- |
| Cl-7.5.4(Doors, Extension Elements and Flaps Opened and Unlocked) |
- |
0 |
|
- |
| Cl-7.5.5(Doors, Extension Elements and Flaps Closed and Locked, All Storage Units Loaded) |
- |
0 |
|
- |
| Cl-7.5.6(Vertical Force Stability Test for Storage Units) |
- |
0 |
|
- |
| Cl-7.5.7(Stability Test for Pedestals/Storage Units with Seat Surfaces) |
- |
0 |
|
- |
| Cl-7.5.8(Dynamic Stability Test for Units with Castors) |
- |
0 |
|
- |
| Cl-7.5.9(Strength Test for Wall Attachments) |
- |
0 |
|
- |
| Cl-9(Marking) |
- |
1000 |
|
- |
|
- |
- Included w.e.f. 11.08.2026 |
| 1338 |
Cotecna Inspection India Private Limited, Gurugram
| 8166106
| IS 17633 (2022) |
Tables and Desks - Specification |
- |
25000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| CLAUSE 4(Design and workmanship) |
- |
1000 |
|
- |
| ClAUSE 5(Dimensions) |
- |
1000 |
|
- |
| CLAUSE 6(SURFACE PERFORMANCE REQUIRMENTS) |
- |
12000 |
|
- |
| CLAUSE 7.2.1(Stability Under Vertical Load) |
- |
1000 |
|
- |
| CLAUSE 7.2.1.1(Test for tables that can be set to a height of 950 mm or less) |
- |
1000 |
|
- |
| CLAUSE 7.2.1.2(" Test for Tables that can be set to a height greater
than 950 mm") |
- |
1000 |
|
- |
| CLAUSE 7.2.2(Stability with Extension Elements Open Place the table on the floor surface) |
- |
1000 |
|
- |
| CLAUSE 7.2.3(Stability Under Horizontal Load) |
- |
1000 |
|
- |
| CLAUSE 7.2.3.1(Test for tables that can be set to a height of 950 mm or less) |
- |
1000 |
|
- |
| CLAUSE 7.2.3.2(" Test for Tables that can be set to a height greater
than 950 mm") |
- |
1000 |
|
- |
| CLAUSE 7.3.1(Strength under Vertical Static Force) |
- |
2000 |
|
- |
| CLAUSE 7.3.1.1(Stated load) |
- |
2000 |
|
- |
| CLAUSE 7.3.1.2(For occasional heavy loads) |
- |
1000 |
|
- |
| CLAUSE 7.3.2(Strength under horizontal static force) |
- |
2000 |
|
- |
| CLAUSE 7.4.1(Durability under Vertical Force) |
- |
5000 |
|
- |
| CLAUSE 7.4.2(Durability of the Height Adjustment Mechanism) |
- |
5000 |
|
- |
| CLAUSE 7.5.1(Durability and Stiffness Under Horizontal Force) |
- |
8000 |
|
- |
| CLAUSE 7.5.2(Durability under Horizontal Force) |
- |
5000 |
|
- |
| CLAUSE 7.5.3(Stiffness of the Structure Under Horizontal Force) |
- |
3000 |
|
- |
| CLAUSE 7.6.1(Vertical Impact Test) |
- |
1000 |
|
- |
| CLAUSE 7.6.2(Vertical Impact Test for Glass Table Tops) |
- |
2000 |
|
- |
| CLAUSE 7.6.3(Vertical Impact Test for All Other Table Tops) |
- |
2000 |
|
- |
| CLAUSE 7.7(Deflection of Table Tops) |
- |
2000 |
|
- |
| CLAUSE 7.8(Durability of Tables with Castors) |
- |
8000 |
|
- |
| CLAUSE 7.9(Drop Test) |
- |
2000 |
|
- |
| Cl - 5(Dimensions) |
- |
0 |
|
- |
| Cl-6 (a)(Resistance to mechanical damage) |
- |
3000 |
|
- |
| Cl-6 (b)(Pencil hardness) |
- |
1000 |
|
- |
| Cl-6 (c)(Resistance to wet heat) |
- |
2000 |
|
- |
| Cl-6 (d)(Resistance to dry heat) |
- |
2000 |
|
- |
| Cl-6 (e)(Resistance to marking by cold liquids) |
- |
3000 |
|
- |
| Cl-6 (f)(Resistance to marking by cold oils and fats) |
- |
2000 |
|
- |
| Cl-6 (g)(Adhesive performance) |
- |
2000 |
|
- |
| Cl-7.2.1(Stability Under Vertical Load) |
- |
0 |
|
- |
| Cl-7.2.2(Stability with Extension Elements Open) |
- |
0 |
|
- |
| Cl-7.2.3(Stability Under Horizontal Load) |
- |
0 |
|
- |
| Cl-7.3.1(Strength under Vertical Static Force) |
- |
0 |
|
- |
| Cl-7.3.2(Strength under horizontal static force) |
- |
0 |
|
- |
| Cl-7.4.1(Durability under Vertical Force) |
- |
0 |
|
- |
| Cl-7.4.2(Durability of the Height Adjustment Mechanism) |
- |
0 |
|
- |
| Cl-7.5.1(General) |
- |
0 |
|
- |
| Cl-7.5.2(Durability under Horizontal Force) |
- |
0 |
|
- |
| Cl-7.5.3(Stiffness of the Structure Under Horizontal Force) |
- |
0 |
|
- |
| Cl-7.6.1(General) |
- |
0 |
|
- |
| Cl-7.6.2(Vertical Impact Test for Glass Table Tops) |
- |
0 |
|
- |
| Cl-7.6.3(Vertical Impact Test for All Other Table Tops) |
- |
0 |
|
- |
| Cl-7.7(Deflection of Table Tops) |
- |
0 |
|
- |
| Cl-7.8(Durability of Tables with Castors) |
- |
0 |
|
- |
| Cl-7.9(Drop Test) |
- |
0 |
|
- |
| Cl-9(Marking) |
- |
0 |
|
- |
| 7.1(General test conditions) |
- |
0 |
|
- |
|
- |
- Included w.e.f. 11.08.2026 |
| 1339 |
Stellar Test House, Noida
| 8171606
| IS 302 : PART 1 (Surface-Cleaning Appliances for Household use Employing Liquids or Steam) |
Surface-Cleaning Appliances for Household use Employing Liquids or Steam |
- |
30000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 6(Classifications) |
- |
500 |
|
- |
| 5(General conditions for tests) |
- |
500 |
|
- |
| 4(General Requirement) |
- |
500 |
|
- |
| 11.8(Temperature rise) |
- |
1000 |
|
- |
| 11.7(Duration corresponding) |
- |
1000 |
|
- |
| 11.6(Combined appliances) |
- |
1000 |
|
- |
| 11.5(Motor-operated appliances) |
- |
1000 |
|
- |
| 11.4(Heating appliances) |
- |
1000 |
|
- |
| 8.1.5(Live parts of built-in appliances) |
- |
1000 |
|
- |
| 18(Endurance) |
- |
1000 |
|
- |
| 17(Overload protection of transformers and associated circuits) |
- |
1000 |
|
- |
| 16(Leakage current and electric strength) |
- |
1000 |
|
- |
| 4(General requirement) |
- |
500 |
|
- |
| 32(Radiation Toxicity and Similar Hazards) |
- |
1000 |
|
- |
| 31(Resistance to Rusting) |
- |
1000 |
|
- |
| 23(General) |
- |
1000 |
|
- |
| 30.2(Needle Flame Test) |
- |
1000 |
|
- |
| 30.2(Glow Wire Test) |
- |
1000 |
|
- |
| 30.1(Ball pressure test) |
- |
1000 |
|
- |
| 29(clearance, creepage distances and solid insulation) |
- |
1000 |
|
- |
| 28(Screw test and connections) |
- |
1000 |
|
- |
| 27(Provision for earthing) |
- |
1000 |
|
- |
| 26(Terminals for external conductors) |
- |
1000 |
|
- |
| 25(Supply connection and external flexible cords) |
- |
1000 |
|
- |
| 24(Components) |
- |
1000 |
|
- |
| 22(Construction verification related test) |
- |
1000 |
|
- |
| 21(Mechanical Strength Test) |
- |
1000 |
|
- |
| 20(Stability test) |
- |
1000 |
|
- |
| 19(Abnormal Operation) |
- |
1000 |
|
- |
| 18(Endurance Test requirements and tests) |
- |
1000 |
|
- |
| 17(Over Load Protection of Transformers and associated circuits) |
- |
1000 |
|
- |
| 16.3(Electric Strength (after clause 15 and 16.2)) |
- |
1000 |
|
- |
| 16.2(Leakage Current (after Clause 15)) |
- |
1000 |
|
- |
| 16.1(General) |
- |
1000 |
|
- |
| 16.0(General) |
- |
1000 |
|
- |
| 15.3(Humidity Test) |
- |
1000 |
|
- |
| 15.2(Spillage Test) |
- |
1000 |
|
- |
| 15.1(Ingress Protection test other than IPX0 (IP test)) |
- |
1000 |
|
- |
| 15.0(General) |
- |
1000 |
|
- |
| 14(Transient Over Voltages) |
- |
1000 |
|
- |
| 13.3(Electric Strength at operating temperature) |
- |
1000 |
|
- |
| 13.2(Leakage current at operating temperature) |
- |
1000 |
|
- |
| 13.1(General) |
- |
1000 |
|
- |
| 11.3(Heating) |
- |
1000 |
|
- |
| 11.2(General) |
- |
1000 |
|
- |
| 11.1(General) |
- |
1000 |
|
- |
| 10.2(Current input) |
- |
1000 |
|
- |
| 10.1(Power input) |
- |
1000 |
|
- |
| 9(Starting of motor operation test requirements and tests) |
- |
1000 |
|
- |
| 8.1.4(Protection against live parts against protective impedance) |
- |
1000 |
|
- |
| 8.1.3(Protection against live parts in visible glowing heating elements) |
- |
1000 |
|
- |
| 8.1.2(Protection against live parts in openings) |
- |
1000 |
|
- |
| 8.1.1(Protection against live parts in all positions) |
- |
1000 |
|
- |
| 7(Marking and instructions) |
- |
500 |
|
- |
|
26 Sep, 2028 |
- "1 19.11.4.7 (Harmonics) EMI/EMC Test Test facilities not available
2 19.11.4.6 (Class 3 Voltage dips and interruptions) EMI/EMC Test Test facilities not available
3 19.11.4.5 (Immunity to conducted discharges) EMI/EMC Test Test facilities not available
4 19.11.4.4 (Surge immunity test) EMI/EMC Test Test facilities not available
5 19.11.4.3 (Fast transient bursts) EMI/EMC Test Test facilities not available
6 19.11.4.2 (Radiated fields) EMI/EMC Test Test facilities not available
7 19.11.4.1 (Electrostatic discharges) EMI/EMC Test Test facilities not available" |
| 1340 |
Cotecna Inspection India Private Limited, Gurugram
| 8166106
| IS 17632 (2022) |
General Purpose Chairs and Stools - Specification |
- |
55000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| CLAUSE 5(DIMENSIONS) |
- |
1000 |
|
- |
| CLAUSE 6(SURFACE PERFORMANCE) |
- |
12000 |
|
- |
| CLAUSE 6.2(Fabric and Leather (Synthetic and Natural) Performance) |
- |
8000 |
|
- |
| CLAUSE 7.2.1(Forwards Overbalancing and Sideways Overbalancing for Chairs without Arms) |
- |
1000 |
|
- |
| CLAUSE 7.2.2(Rearwards Overbalancing) |
- |
1000 |
|
- |
| CLAUSE 7.2.3(Sideways Overbalancing for Chairs with Arms) |
- |
1000 |
|
- |
| CLAUSE 7.2.4(Sideways Overbalancing for Chairs with Arms) |
- |
0 |
|
- |
| CLAUSE 7.3.1.1(Seat static load test) |
- |
2000 |
|
- |
| CLAUSE 7.3.1.2(Back static load test) |
- |
2000 |
|
- |
| CLAUSE 7.3.1.3(Armrests/Wings sideways static load test) |
- |
2000 |
|
- |
| CLAUSE 7.3.1.4(Arm downwards static load test) |
- |
2000 |
|
- |
| CLAUSE 7.3.1.5(Leg forward static load test) |
- |
2000 |
|
- |
| CLAUSE 7.3.1.6(Leg sideways static load test) |
- |
2000 |
|
- |
| CLAUSE 7.3.1.7(Diagonal base load test) |
- |
2000 |
|
- |
| CLAUSE 7.3.1.8(Foot rest static-load test) |
- |
2000 |
|
- |
| CLAUSE 7.3.2.1(Seat impact test) |
- |
2000 |
|
- |
| CLAUSE 7.3.2.2(Back impact test) |
- |
2000 |
|
- |
| CLAUSE 7.3.2.3(Arm impact test) |
- |
2000 |
|
- |
| CLAUSE 7.3.2.4(Drop test) |
- |
2000 |
|
- |
| CLAUSE 7.4.1(Seat Fatigue Test) |
- |
10000 |
|
- |
| CLAUSE 7.4.2(Back Fatigue Test) |
- |
10000 |
|
- |
| CLAUSE 7.4.3(Arm Rest Durability Test) |
- |
8000 |
|
- |
| Cl - 5(DIMENSIONS) |
- |
0 |
|
- |
| Cl-6.1 (a)(Resistance to mechanical damage) |
- |
3000 |
|
- |
| Cl-6.1 (b)(Pencil hardness) |
- |
1000 |
|
- |
| Cl-6.1 (c)(Resistance to wet heat) |
- |
2000 |
|
- |
| Cl-6.1 (d)(Resistance to dry heat) |
- |
2000 |
|
- |
| Cl-6.1 (e)(Resistance to marking by cold liquids) |
- |
3000 |
|
- |
| Cl-6.1 (f)(Resistance to marking by cold oils and fats) |
- |
3000 |
|
- |
| Cl-6.1 (g)(Adhesive performance) |
- |
2000 |
|
- |
| Cl-6.2 (a) 1(Breaking load) |
- |
600 |
|
- |
| Cl-6.2 (a) 2(Elongation at break) |
- |
600 |
|
- |
| Cl-6.2 (a) 3(Tear strength) |
- |
600 |
|
- |
| Cl-6.2 (a) 4(Colour fastness to light) |
- |
1000 |
|
- |
| Cl-6.2 (a) 5(Colour fastness to rubbing) |
- |
400 |
|
- |
| Cl-6.2 (a) 6(Colour fastness to perspiration) |
- |
650 |
|
- |
| Cl-6.2 (a) 7(Colour fastness to water) |
- |
500 |
|
- |
| Cl-6.2 (a) 8(Pilling resistance) |
- |
1000 |
|
- |
| Cl-6.2 (a) 9(Coating adhesion strength) |
- |
700 |
|
- |
| Cl-6.2 (a) 10(Seam slippage) |
- |
800 |
|
- |
| Cl-6.2 (a) 11(Resistance to damage by flexing) |
- |
2000 |
|
- |
| Cl-6.2 (a) 12(Abrasion resistance) |
- |
1000 |
|
- |
| Cl-6.2 (a) 13(Bursting strength) |
- |
700 |
|
- |
| Cl-6.2 (a) 14(Resistance to cold) |
- |
500 |
|
- |
| Cl-6.2 (b) 1(Tear strength) |
- |
650 |
|
- |
| Cl-6.2 (b) 2(Flexing endurance) |
- |
2000 |
|
- |
| Cl-6.2 (b) 3(Finish adhesion) |
- |
700 |
|
- |
| Cl-6.2 (b) 4(Colour fastness to artificial light) |
- |
2000 |
|
- |
| Cl-6.2 (b) 5(Colour fastness to rubbing) |
- |
1000 |
|
- |
| Cl-6.2 (b) 6(Colour fastness to water spotting) |
- |
500 |
|
- |
| Cl-6.2 (b) 7(Water vapour permeability) |
- |
700 |
|
- |
| Cl-6.2 (b) 8(Colour fastness to water) |
- |
600 |
|
- |
| Cl-7.2.1(Forwards Overbalancing and Sideways Overbalancing for Chairs without Arms) |
- |
0 |
|
- |
| Cl-7.2.2(Rearwards Overbalancing) |
- |
0 |
|
- |
| Cl-7.2.3(Sideways Overbalancing for Chairs with Arms) |
- |
0 |
|
- |
| Cl-7.2.4(Stools/ Poufs (All Directions)) |
- |
1000 |
|
- |
| Cl-7.3.1(Static Load Test) |
- |
0 |
|
- |
| Cl-7.3.2(Impact Test) |
- |
0 |
|
- |
| Cl-7.4.1(Seat Fatigue Test) |
- |
0 |
|
- |
| Cl-7.4.2(Back Fatigue Test) |
- |
0 |
|
- |
| Cl-7.4.3(Arm Rest Durability) |
- |
0 |
|
- |
| Cl-9(Marking) |
- |
0 |
|
- |
| 7.1(General test conditions) |
- |
0 |
|
- |
|
- |
- Included w.e.f. 11.08.2026 |
| 1341 |
ACCURATE TEST SOLUTIONS LLP
| 8192806
| IS 15532 (2004) |
Plastics crates for fruits and vegetables - Specification |
All variety |
30000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 3, 3.1(Requirements) |
- |
500 |
|
- |
| 3.2(Material) |
- |
0 |
|
- |
| 3.3(Shape, Dimensions and Design) |
- |
3000 |
|
- |
| 3.4(Mass) |
- |
2000 |
|
- |
| 3.5(Appearance and Surface Finish) |
- |
1000 |
|
- |
| 3.6(Dimensional Stability) |
- |
3000 |
|
- |
| 3.7(Confluence Line Strength) |
- |
3000 |
|
- |
| 3.8.1(Compressive Strength (Resistance to Applied
Load)) |
- |
3000 |
|
- |
| 3.8.2(Resistance to Drop) |
- |
4000 |
|
- |
| 3.9(Resistance to Environmental Stress Cracking) |
- |
3000 |
|
- |
| 3.10.1(Suspension Test) |
- |
2000 |
|
- |
| 3.10.2(Free-Fall Test) |
- |
3000 |
|
- |
| 3.1(Crates) |
- |
2000 |
|
- |
| 3.2(Material) |
- |
0 |
|
- |
| 3.3(Shape, Dimensions and Design) |
- |
0 |
|
- |
| 3.4(Mass) |
- |
0 |
|
- |
| 3.5(Appearance and Surface Finish) |
- |
0 |
|
- |
| 3.6(Dimensional Stability) |
- |
0 |
|
- |
| 3.7(Confluence line Strength) |
- |
0 |
|
- |
| 3.8(Mechanical Strength) |
- |
0 |
|
- |
| 3.9(Resistance to Environmental Stress Cracking) |
- |
0 |
|
- |
| 3.10(Handle Test) |
- |
0 |
|
- |
| 4(Packing and Marking) |
- |
500 |
|
- |
| 3, 3.1(Requirements) |
- |
0 |
|
- |
| 3.2(Material) |
- |
0 |
|
- |
| 3.3(Shape, Dimensions and Design) |
- |
0 |
|
- |
| 3.4(Mass) |
- |
0 |
|
- |
| 3.5(Appearance and Surface Finish) |
- |
0 |
|
- |
| 3.6(Dimensional Stability) |
- |
0 |
|
- |
| 3.7(Confluence Line Strength) |
- |
0 |
|
- |
| 3.8.1(Compressive Strength (Resistance to Applied
Load)) |
- |
0 |
|
- |
| 3.8.2(Resistance to Drop) |
- |
0 |
|
- |
| 3.9(Resistance to Environmental Stress Cracking) |
- |
0 |
|
- |
| 3.10.1(Suspension Test) |
- |
0 |
|
- |
| 3.10.2(Free-Fall Test) |
- |
0 |
|
- |
| 3.1(Crates) |
- |
0 |
|
- |
| 3.2(Material) |
- |
0 |
|
- |
| 3.3(Shape, Dimensions and Design) |
- |
0 |
|
- |
| 3.4(Mass) |
- |
0 |
|
- |
| 3.5(Appearance and Surface Finish) |
- |
0 |
|
- |
| 3.6(Dimensional Stability) |
- |
0 |
|
- |
| 3.7(Confluence line Strength) |
- |
0 |
|
- |
| 3.8(Mechanical Strength) |
- |
0 |
|
- |
| 3.9(Resistance to Environmental Stress Cracking) |
- |
0 |
|
- |
| 3.10(Handle Test) |
- |
0 |
|
- |
| 4(Packing and Marking) |
- |
500 |
|
- |
| 3, 3.1(Requirements) |
- |
- |
|
- |
| 3.2(Material) |
- |
- |
|
- |
| 3.3(Shape, Dimensions and Design) |
- |
- |
|
- |
| 3.4(Mass) |
- |
- |
|
- |
| 3.5(Appearance and Surface Finish) |
- |
- |
|
- |
| 3.6(Dimensional Stability) |
- |
- |
|
- |
| 3.7(Confluence Line Strength) |
- |
- |
|
- |
| 3.8.1(Compressive Strength (Resistance to Applied
Load)) |
- |
- |
|
- |
| 3.8.2(Resistance to Drop) |
- |
- |
|
- |
| 3.9(Resistance to Environmental Stress Cracking) |
- |
- |
|
- |
| 3.10.1(Suspension Test) |
- |
- |
|
- |
| 3.10.2(Free-Fall Test) |
- |
- |
|
- |
| 3.1(Crates) |
- |
- |
|
- |
| 3.2(Material) |
- |
- |
|
- |
| 3.3(Shape, Dimensions and Design) |
- |
- |
|
- |
| 3.4(Mass) |
- |
- |
|
- |
| 3.5(Appearance and Surface Finish) |
- |
- |
|
- |
| 3.6(Dimensional Stability) |
- |
- |
|
- |
| 3.7(Confluence line Strength) |
- |
- |
|
- |
| 3.8(Mechanical Strength) |
- |
- |
|
- |
| 3.9(Resistance to Environmental Stress Cracking) |
- |
- |
|
- |
| 3.10(Handle Test) |
- |
- |
|
- |
| 4(Packing and Marking) |
- |
- |
|
- |
|
08 Dec, 2028 |
- Included w.e.f 09.06.2026 |
| 1342 |
Shri Krishna Test House
| 8122336
| IS 21 (2025) |
Wrought Aluminium and Aluminium Alloys for Manufacture of Utensils - Specification (Fifth Revision) |
ALL |
70000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl-4(General requirements) |
- |
500 |
|
- |
| Cl-5.1(Material) |
- |
6000 |
|
- |
| Cl-5.2(Chemical composition and mechanical properties of grades in Cl 5.1) |
- |
6500 |
|
- |
| Cl-5.3.1 a("Wrought Aluminium (with Minimum
99 Percent Al Content)- Iron+ Silicon") |
- |
1000 |
|
- |
| Cl-5.3.1 b("Wrought Aluminium (with Minimum
99 Percent Al Content)- Chromium") |
- |
1000 |
|
- |
| Cl-5.3.1 b("Wrought Aluminium (with Minimum
99 Percent Al Content)- Magnesium") |
- |
1000 |
|
- |
| Cl-5.3.1 b("Wrought Aluminium (with Minimum
99 Percent Al Content)- Manganese") |
- |
1000 |
|
- |
| Cl-5.3.1 b("Wrought Aluminium (with Minimum
99 Percent Al Content)- Nickel") |
- |
1000 |
|
- |
| Cl-5.3.1 b("Wrought Aluminium (with Minimum
99 Percent Al Content)- Zinc") |
- |
1000 |
|
- |
| Cl-5.3.1 b("Wrought Aluminium (with Minimum
99 Percent Al Content)- Titanium") |
- |
1000 |
|
- |
| Cl-5.3.1 b("Wrought Aluminium (with Minimum
99 Percent Al Content)- Tin") |
- |
1000 |
|
- |
| Cl-5.3.1 c("Wrought Aluminium (with Minimum
99 Percent Al Content)- Copper") |
- |
1000 |
|
- |
| Cl-5.3.1 Note 1("Wrought Aluminium (with Minimum
99 Percent Al Content)- Aluminium") |
- |
1000 |
|
- |
| Cl-5.3.1 d("Wrought Aluminium (with Minimum
99 Percent Al Content)- Others") |
- |
1000 |
|
- |
| Cl-5.3.2, Table-1 (i)(Wrought Aluminium Alloys-Silicon) |
- |
1000 |
|
- |
| Cl-5.3.2, Table-1 (ii)(Wrought Aluminium Alloys-Iron) |
- |
800 |
|
- |
| Cl-5.3.2, Table-1 (iii)(Wrought Aluminium Alloys-Copper) |
- |
800 |
|
- |
| Cl-5.3.2, Table-1 (iv)(Wrought Aluminium Alloys-Manganese) |
- |
800 |
|
- |
| Cl-5.3.2, Table-1 (v)(Wrought Aluminium Alloys-Magnesium) |
- |
800 |
|
- |
| Cl-5.3.2, Table-1 (vi)(Wrought Aluminium Alloys-Chromium) |
- |
800 |
|
- |
| Cl-5.3.2, Table-1 (vii)(Wrought Aluminium Alloys-Nickel) |
- |
800 |
|
- |
| Cl-5.3.2, Table-1 (viii)(Wrought Aluminium Alloys-Zinc) |
- |
800 |
|
- |
| Cl-5.3.2, Table-1 (ix)(Wrought Aluminium Alloys -Zirconium) |
- |
1500 |
|
- |
| Cl-5.3.2, Table-1 (x)(Wrought Aluminium Alloys - Titanium) |
- |
600 |
|
- |
| Cl-5.3.2, Table-1 (Note 3)(Wrought Aluminium Alloys- Aluminium) |
- |
1000 |
|
- |
| Cl-5.3.2, Table-1 (xi)(Wrought Aluminium Alloys- Others) |
- |
1000 |
|
- |
| Cl 5.4(Lead) |
- |
800 |
|
- |
| Cl 5.4(Cadmium) |
- |
800 |
|
- |
| Cl 5.4(Arsenic) |
- |
800 |
|
- |
| Cl-7(Dimension) |
- |
500 |
|
- |
| Cl-8(EARING TEST (OPTIONAL TEST)) |
- |
2000 |
|
- |
| Cl-5.2, (Cl-8,Table 2 of IS 737)(0.2% Proof Stress) |
- |
2500 |
|
- |
| Cl-5.2, (Cl-8,Table 2 of IS 737)(Tensile Strength) |
- |
2500 |
|
- |
| Cl-5.2, (Cl-8,Table 2 of IS 737)(Elongation) |
- |
1500 |
|
- |
| Cl-5.2, (Cl-8,Table 2 of IS 737)(Bend Test) |
- |
3000 |
|
- |
|
05 Oct, 2028 |
- Included w.e.f 09.03.2026 |
| 1343 |
Shri Krishna Test House
| 8122336
| IS 733 (2025) |
Wrought Aluminium and Aluminium Alloy Bars, Rods, Sections, Extruded Tube, Hollow Sections and Profiles for General Engineering Purposes ? Specification (Fourth Revision) |
All |
6000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl. 6 Table 1 - Table 8(Sodium) |
- |
500 |
|
- |
| Cl. 6 Table 1 - Table 8(Strontium) |
- |
500 |
|
- |
| Cl. 6 Table 1 - Table 8(Antimony) |
- |
500 |
|
- |
| Cl. 6 Table 1 - Table 8(Phosphorus) |
- |
500 |
|
- |
| Cl. 6 Table 1 - Table 8(Zirconium +Titanium) |
- |
500 |
|
- |
| Cl-4(General requirements) |
- |
500 |
|
- |
| Cl-6.1, Table-1 to 8(Fe) |
- |
500 |
|
- |
| Cl-6.1, Table-1 to 8(Cu) |
- |
500 |
|
- |
| Cl-6.1, Table-1 to 8(Mn) |
- |
500 |
|
- |
| Cl-6.1, Table-1 to 8(Mg) |
- |
500 |
|
- |
| Cl-6.1, Table-1 to 8(Cr) |
- |
500 |
|
- |
| Cl-6.1, Table-1 to 8(Zn) |
- |
500 |
|
- |
| Cl-6.1, Table-1 to 8(Ti) |
- |
500 |
|
- |
| Cl-6.1, Table-1 to 8(V) |
- |
500 |
|
- |
| Cl-6.1, Table-1 to 8(Aluminium) |
- |
500 |
|
- |
| Cl-6.2(chemical analysis) |
- |
4000 |
|
- |
| Cl-7.1, 7.2 & 7.3, Table-9(Dimensions) |
- |
500 |
|
- |
| Cl-7.1, 7.2 & 7.3, Table-9(Rm MPa) |
- |
500 |
|
- |
| Cl-7.1, 7.2 & 7.3, Table-9(Rp0.2 MPa) |
- |
500 |
|
- |
| Cl-7.1, 7.2 & 7.3, Table-9(Elongation , Percent) |
- |
1500 |
|
- |
| Cl-9(Dimensions and Tolerances) |
- |
500 |
|
- |
| Cl-12(Packaging and Marking) |
- |
100 |
|
- |
| Cl-7.1(Tensile test) |
- |
2500 |
|
- |
| Cl-5(Freedom from Defects) |
- |
500 |
|
- |
| Cl-6.1, Table-1 to 8(Si) |
- |
500 |
|
- |
|
05 Oct, 2028 |
- Included w.e.f 09.03.2026 |
| 1344 |
QUALITY INTERNATIONAL RESEARCH & LABORATORIES PRIVATE LIMITED
| 5197006
| IS 10748 (2025) |
Hot-Rolled Steel Strip for Welded Tubes and Pipes - Specification ( Third Revision) |
Hot Rolled Steel Strips |
12500 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl-4(Supply of Materials) |
- |
500 |
|
- |
| Cl-6(Manufacture) |
- |
500 |
|
- |
| Cl-7.1(Ladle Analysis) |
- |
2500 |
|
- |
| Cl-7.2(Product Analysis) |
- |
2500 |
|
- |
| Cl-7.3(Carbon Equivalent Value) |
- |
500 |
|
- |
| Cl-8.1(Number of Tensile Tests) |
- |
2500 |
|
- |
| Cl-8.2(Tensile Test Pieces) |
- |
1000 |
|
- |
| Cl-8.3(Tensile Test) |
- |
2500 |
|
- |
| Cl-8.3, Table-5 & 6(Tensile Strength, MPa) |
- |
1000 |
|
- |
| Cl-8.3, Table-5 & 6(Yield Strength, MPa) |
- |
1000 |
|
- |
| Cl-8.3, Table-5 & 6(Internal Diameter of Bend) |
- |
500 |
|
- |
| Cl-9.1(Number of Bend Tests) |
- |
500 |
|
- |
| Cl-9.2(Bend test) |
- |
500 |
|
- |
| Cl-10(Re- Tests) |
- |
12500 |
|
- |
| Cl-11(freedam from Defects) |
- |
500 |
|
- |
| Cl-12(Dimensions) |
- |
500 |
|
- |
| Cl-13(Tolerances) |
- |
500 |
|
- |
| Cl-14(Calculation of Mass) |
- |
500 |
|
- |
| Cl-16(Marking) |
- |
500 |
|
- |
| Cl-7.1, 7.2, 7.3 & 7.4(Carbon) |
- |
500 |
|
- |
| Cl-7.1, 7.2, 7.3 & 7.4(Manganese) |
- |
500 |
|
- |
| Cl-7.1, 7.2, 7.3 & 7.4(Sulphur) |
- |
500 |
|
- |
| Cl-7.1, 7.2, 7.3 & 7.4(Phosphorus) |
- |
500 |
|
- |
| Cl-7.1, 7.2, 7.3 & 7.4(Carbon Equivalent Value (CEV)) |
- |
500 |
|
- |
| Cl-7.1, 7.2, 7.3 & 7.4(silicon) |
- |
500 |
|
- |
| Cl-7.1, 7.2, 7.3 & 7.4(aluminium) |
- |
500 |
|
- |
| Cl-7.1, 7.2, 7.3 & 7.4(total aluminium) |
- |
500 |
|
- |
| Cl-7.1, 7.2, 7.3 & 7.4(Niobium) |
- |
500 |
|
- |
| Cl-7.1, 7.2, 7.3 & 7.4(Vanadium) |
- |
500 |
|
- |
| Cl-7.1, 7.2, 7.3 & 7.4(Titanium) |
- |
500 |
|
- |
| Cl-7.1, 7.2, 7.3 & 7.4(Nitrogen) |
- |
2500 |
|
- |
| Cl-7.1, 7.2, 7.3 & 7.4(Copper) |
- |
500 |
|
- |
| Cl-7.1, 7.2, 7.3 & 7.4(Mo + Cr +W) |
- |
1500 |
|
- |
| Cl-7.1, 7.2, 7.3 & 7.4(Mo) |
- |
500 |
|
- |
| Cl-7.1, 7.2, 7.3 & 7.4(Boron) |
- |
500 |
|
- |
| Cl-7.1, 7.2, 7.3 & 7.4(Nickel) |
- |
500 |
|
- |
| Cl-7.1, 7.2, 7.3 & 7.4(Chromium) |
- |
500 |
|
- |
| Cl-8.3, Table-5 & 6(Elongation at Gauge Length,) |
- |
1000 |
|
- |
|
- |
- included w.e.f 09.03.2026 |
| 1345 |
Shri Krishna Test House
| 8122336
| IS 1285 (2023) |
WROUGHT ALUMINIUM AND ALUMINIUM ALLOYS EXTRUDED ROUND TUBE AND HOLLOW SECTIONS FOR GENERAL ENGINEERINGPURPOSES SPECIFICATION |
All |
10000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl.9.1(Aluminium- IS 504 and its parts or any other intrumental/chemical methods) |
- |
500 |
|
- |
| Cl.9.1(Copper- IS 504 and its parts or any other intrumental/chemical methods) |
- |
500 |
|
- |
| Cl.9.1(Magnesium- IS 504 and its parts or any other intrumental/chemical methods) |
- |
500 |
|
- |
| Cl.9.1(Silicon- IS 504 and its parts or any other intrumental/chemical methods) |
- |
500 |
|
- |
| Cl.9.1(Iron- IS 504 and its parts or any other intrumental/chemical methods) |
- |
500 |
|
- |
| Cl.9.1(Manganese- IS 504 and its parts or any other intrumental/chemical methods) |
- |
500 |
|
- |
| Cl.9.1(Zinc- IS 504 and its parts or any other intrumental/chemical methods) |
- |
500 |
|
- |
| Cl.9.1(Titanium and/ or other grain refining elements- IS 504 and its parts or any other intrumental/chemical methods) |
- |
500 |
|
- |
| Cl.9.1(Chromium- IS 504 and its parts or any other intrumental/chemical methods) |
- |
500 |
|
- |
| Cl.9.1(Remarks (Ti+V) - IS 504 and its parts or any other intrumental/chemical methods) |
- |
500 |
|
- |
| Cl.9.1(Remarks (Cr+Mn) - IS 504 and its parts or any other intrumental/chemical methods) |
- |
500 |
|
- |
| Cl.9.1(Remarks (Total Impurities)- IS 504 and its parts or any other intrumental/chemical methods) |
- |
500 |
|
- |
| 6(FREEDOM FROM DEFECTS) |
- |
1000 |
|
- |
| 8(DIMENSIONS AND TOLERANCES) |
- |
500 |
|
- |
| 10(MECHANICAL PROPERTIES) |
- |
7000 |
|
- |
| Cl. 9(Aluminium) |
- |
500 |
|
- |
| Cl. 9(Copper) |
- |
500 |
|
- |
| Cl. 9(Magnesium) |
- |
500 |
|
- |
| Cl. 9(Silicon) |
- |
500 |
|
- |
| Cl. 9(Iron) |
- |
500 |
|
- |
| Cl. 9(Manganese) |
- |
500 |
|
- |
| Cl. 9(Zinc) |
- |
500 |
|
- |
| Cl. 9(Titanium and/or other grain refining elements) |
- |
500 |
|
- |
| Cl. 9(Chromium) |
- |
500 |
|
- |
| Cl. 9(Ti+V) |
- |
500 |
|
- |
| Cl. 9(Cr+Mn) |
- |
500 |
|
- |
| Clause-10(Tensile strength) |
- |
2500 |
|
- |
| Clauses 9.2(Ni) |
- |
500 |
|
- |
| Clauses 9.2(Pb) |
- |
500 |
|
- |
| Clauses 9.2(Sn) |
- |
500 |
|
- |
| Clauses 9.2(Ag) |
- |
1000 |
|
- |
| Clauses 9.2(Be) |
- |
500 |
|
- |
| Clauses 9.2(Zr) |
- |
1500 |
|
- |
| Clauses 9.2(Co) |
- |
500 |
|
- |
|
05 Oct, 2028 |
- Included w.e.f 09.03.2026 |
| 1346 |
Elutech Laboratory and Calibration Services, Jaipur
| 9179806
| IS 2202 : Part 2 (2022) |
WOODEN FLUSH DOOR SHUTTERS SOLID CORE TYPE SPECIFICATION PART 2 PARTICLE BOARD HIGH DENSITY FIBRE BOARD MEDIUM DENSITY FIBRE BOARD AND HARDBOARD FACE PANELS Fourth Revision |
All Grade / Type / Size / Designation |
24000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Clause No - 6.1(Timber) |
- |
24000 |
|
24000 complete testing charges. |
| Clause No -6.2(Alternative Materials (LVL) |
- |
15000 |
|
- |
| Clause No -6.2(Alternative Materials veneer laminated lumber (VLL)) |
- |
15000 |
|
- |
| Clause No -6.2(Alternative Materials medium density fibre board (MDF)) |
- |
15000 |
|
- |
| Clause No -6.2(Alternative Materials -plywood) |
- |
10000 |
|
- |
| Clause No -6.2(BWP grade flush door shutter) |
- |
24000 |
|
- |
| Clause No -6.3.1("Face Panels:
Particle Board
MDF/ HDF
Fibre Hardboard") |
- |
24000 |
|
- |
| Clause No -6.4(Adhesive) |
- |
10000 |
|
- |
| Clause No -7.1(Construction) |
- |
5000 |
|
- |
| Clause No - 7.3(" MDF board or
HDF board ") |
- |
15000 |
|
- |
| Clause No -9.2("Workmanship and
finish") |
- |
1000 |
|
- |
| Clause No -10.1(tests for flush door shutters) |
- |
24000 |
|
- |
| Clause No -10.2(End Immersion Test) |
- |
5000 |
|
- |
| Clause No -10.3(Glue Adhesion Test) |
- |
5000 |
|
- |
| Clause No -11(SAMPLING AND CRITERIA FOR CONFORMITY) |
- |
0 |
|
- |
| Clause No -12("ADDITIONAL REQUIREMENTS FOR ECO
MARK") |
- |
0 |
|
- |
| 5(SIZES AND TOLERANCES) |
- |
1000 |
|
- |
| 6.5(The swelling in thickness of the particle board, MDF
and HDF board for core) |
- |
5000 |
|
- |
| Cl-6.3.3 (Amendment NO 1)(B D P V, P D P V and M D P V types of flush door) |
- |
0 |
|
- |
| Cl-6.3.2(MDF board and HDF board) |
- |
15000 |
|
- |
| Cl-6.3.4(B N P V, P N P V and M N P V,) |
- |
0 |
|
- |
| Cl-7.2(Face Panel) |
- |
1000 |
|
- |
| Cl-7.4 (Amendment No 1)(Door Blanks) |
- |
15000 |
|
- |
| Cl-8(Fittings) |
- |
0 |
|
- |
|
26 Aug, 2027 |
- included w.e.f 24.03.2026 |
| 1347 |
Elutech Laboratory and Calibration Services, Jaipur
| 9179806
| IS 2191 : Part 2 (2022) |
WOODEN FLUSH DOOR SHUTTERS (CELLULAR, HOLLOW AND TUBULAR CORE TYPE) - SPECIFICATION PART 2 PARTICLE BOARD, HIGH DENSITY FIBRE BOARD, MEDIUM DENSITY FIBRE BOARD AND FIBRE HARDBOARD FACE PANELS (Fourth Revision) |
All Grade / Type / Size / Designation |
24000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl-5(Sizes and Tolerances) |
- |
500 |
|
24000 complete testing charges |
| Cl-6.1.(Timber) |
- |
1000 |
|
- |
| Cl-6.2(Laminated veneer lumber (LVL), veneer laminated lumber (VLL), medium density fibre board (MDF), high density fibre board (HDF)) |
- |
15000 |
|
- |
| Cl-6.3.1(Particle board) |
- |
15000 |
|
- |
| Cl-6.3.2(MDF board and HDF board) |
- |
15000 |
|
- |
| Cl-6.3.5(shutters with fibre hardboard face) |
- |
15000 |
|
- |
| Cl-8.1(Locks) |
- |
0 |
|
- |
| Cl-10.1(various test) |
- |
24000 |
|
- |
| Cl-10.2(End Immersion Test) |
- |
5000 |
|
- |
| Cl-10.3(Glue Adhesion Test) |
- |
5000 |
|
- |
| Cl-13(Marking) |
- |
0 |
|
- |
| Cl-5(Sizes and Tolerances) |
- |
24000 |
|
24000 complete testing charges |
| Cl-6.1.(Timber) |
- |
24000 |
|
24000 complete testing charges |
| Cl-6.2(Laminated veneer lumber (LVL), veneer laminated lumber (VLL), medium density fibre board (MDF), high density fibre board (HDF)) |
- |
24000 |
|
24000 complete testing charges |
| Cl-6.3.1(Particle board) |
- |
24000 |
|
24000 complete testing charges |
| Cl-6.3.2(MDF board and HDF board) |
- |
24000 |
|
24000 complete testing charges |
| Cl-6.3.5(shutters with fibre hardboard face) |
- |
24000 |
|
24000 complete testing charges |
| Cl-8.1(Locks) |
- |
24000 |
|
24000 complete testing charges |
| Cl-10.1(various test) |
- |
24000 |
|
24000 complete testing charges |
| Cl-10.2(End Immersion Test) |
- |
24000 |
|
24000 complete testing charges |
| Cl-10.3(Glue Adhesion Test) |
- |
24000 |
|
24000 complete testing charges |
| Cl-13(Marking) |
- |
24000 |
|
24000 complete testing charges |
|
26 Aug, 2027 |
- included w.e.f 24.03.2026 |
| 1348 |
Elutech Laboratory and Calibration Services, Jaipur
| 9179806
| IS 1381 : Part 2 (2019) |
Laboratory glassware - Boiling flasks: Part 2 boiling flasks with conical ground joints (Third Revision) |
Conical flask / Flat-bottom flask /Round-bottom flask |
12000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 3(Type) |
- |
1000 |
|
- |
| 4(Series of capacities) |
- |
1000 |
|
- |
| 5(Material) |
- |
0 |
|
Not applicable, as raw material test has been excluded. |
| 5(Material) |
- |
0 |
|
Not applicable, as raw material test has been excluded. |
| 6(Dimensions) |
- |
1000 |
|
- |
| 6(Dimensions) |
- |
1000 |
|
- |
| 6(Dimensions) |
- |
1000 |
|
- |
| 6(Dimensions) |
- |
1000 |
|
- |
| 7(Ground glass joints) |
- |
1000 |
|
- |
| 8(Thermal shock endurance) |
- |
5000 |
|
- |
| 9(Marking) |
- |
100 |
|
- |
| 9(Marking) |
- |
100 |
|
- |
| 9(Marking) |
- |
100 |
|
- |
| 9(Marking) |
- |
100 |
|
- |
| 3(Type) |
- |
1000 |
|
- |
| 4(Series of capacities) |
- |
1000 |
|
- |
| 5(Material) |
- |
0 |
|
Not applicable, as raw material test has been excluded. |
| 5(Material) |
- |
0 |
|
Not applicable, as raw material test has been excluded. |
| 6(Dimensions) |
- |
1000 |
|
- |
| 6(Dimensions) |
- |
1000 |
|
- |
| 6(Dimensions) |
- |
1000 |
|
- |
| 6(Dimensions) |
- |
1000 |
|
- |
| 7(Ground glass joints) |
- |
1000 |
|
- |
| 8(Thermal shock endurance) |
- |
5000 |
|
- |
| 9(Marking) |
- |
100 |
|
- |
| 9(Marking) |
- |
100 |
|
- |
| 9(Marking) |
- |
100 |
|
- |
| 9(Marking) |
- |
100 |
|
- |
| 3(Type) |
- |
1000 |
|
- |
| 4(Series of capacities) |
- |
1000 |
|
- |
| 5(Material) |
- |
0 |
|
Not applicable, as raw material test has been excluded. |
| 5(Material) |
- |
0 |
|
Not applicable, as raw material test has been excluded. |
| 6(Dimensions) |
- |
1000 |
|
- |
| 6(Dimensions) |
- |
1000 |
|
- |
| 6(Dimensions) |
- |
1000 |
|
- |
| 6(Dimensions) |
- |
1000 |
|
- |
| 7(Ground glass joints) |
- |
1000 |
|
- |
| 8(Thermal shock endurance) |
- |
5000 |
|
- |
| 9(Marking) |
- |
100 |
|
- |
| 9(Marking) |
- |
100 |
|
- |
| 9(Marking) |
- |
100 |
|
- |
| 9(Marking) |
- |
100 |
|
- |
| 3(Type) |
- |
1000 |
|
- |
| 4(Series of capacities) |
- |
1000 |
|
- |
| 5(Material) |
- |
0 |
|
Not applicable, as raw material test has been excluded. |
| 5(Material) |
- |
0 |
|
Not applicable, as raw material test has been excluded. |
| 6(Dimensions) |
- |
1000 |
|
- |
| 6(Dimensions) |
- |
1000 |
|
- |
| 6(Dimensions) |
- |
1000 |
|
- |
| 6(Dimensions) |
- |
1000 |
|
- |
| 7(Ground glass joints) |
- |
1000 |
|
- |
| 8(Thermal shock endurance) |
- |
5000 |
|
- |
| 9(Marking) |
- |
100 |
|
- |
| 9(Marking) |
- |
100 |
|
- |
| 9(Marking) |
- |
100 |
|
- |
| 9(Marking) |
- |
100 |
|
- |
| 3(Type) |
- |
1000 |
|
- |
| 4(Series of capacities) |
- |
1000 |
|
- |
| 5(Material) |
- |
0 |
|
Not applicable, as raw material test has been excluded. |
| 5(Material) |
- |
0 |
|
Not applicable, as raw material test has been excluded. |
| 6(Dimensions) |
- |
1000 |
|
- |
| 6(Dimensions) |
- |
1000 |
|
- |
| 6(Dimensions) |
- |
1000 |
|
- |
| 6(Dimensions) |
- |
1000 |
|
- |
| 7(Ground glass joints) |
- |
1000 |
|
- |
| 8(Thermal shock endurance) |
- |
5000 |
|
- |
| 9(Marking) |
- |
100 |
|
- |
| 9(Marking) |
- |
99.99 |
|
- |
| 9(Marking) |
- |
100 |
|
- |
| 9(Marking) |
- |
100 |
|
- |
|
26 Aug, 2027 |
- Included w.e.f 09.06.2026 |
| 1349 |
MATERIAL TESTING LABORATORY LLP
| 8176306
| IS 210 (2009) |
Grey iron castings - Specification (First Revision) |
ALL |
5000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 6(Chemical Composition(chemical
composition shall be as agreed to between the
purchaser and the manufacturer.)) |
- |
1500 |
|
- |
| 7.1(WORKMANSHIP AND FINISH) |
- |
100 |
|
- |
| 10.1(FREEDOM FROM DEFECTS) |
- |
100 |
|
- |
| 10.2(FREEDOM FROM DEFECTS) |
- |
0 |
|
- |
| 13(SIZE OF TEST BARS-Diameter) |
- |
100 |
|
- |
| 13(SIZE OF TEST BARS-Length) |
- |
100 |
|
- |
| 15, Table 3(TENSIL.E TEST- IS 1608 Part1 ) |
- |
1000 |
|
- |
| 16, Table 3(Hardness Test) |
- |
500 |
|
- |
| 17,Annex B(TRANSVERSE TEST) |
- |
500 |
|
- |
| 18(HYDROSTATIC TEST) |
- |
1000 |
|
- |
| 6(Chemical Composition(chemical
composition shall be as agreed to between the
purchaser and the manufacturer.)) |
- |
0 |
|
- |
| 7.1(WORKMANSHIP AND FINISH) |
- |
0 |
|
- |
| 10.1(FREEDOM FROM DEFECTS) |
- |
0 |
|
- |
| 10.2(FREEDOM FROM DEFECTS) |
- |
0 |
|
- |
| 13(SIZE OF TEST BARS-Diameter) |
- |
0 |
|
- |
| 13(SIZE OF TEST BARS-Length) |
- |
0 |
|
- |
| 15, Table 3(TENSIL.E TEST- IS 1608 Part1 ) |
- |
0 |
|
- |
| 16, Table 3(Hardness Test) |
- |
0 |
|
- |
| 17,Annex B(TRANSVERSE TEST) |
- |
0 |
|
- |
| 18(HYDROSTATIC TEST) |
- |
0 |
|
- |
| 9(IS 7754) |
- |
0 |
|
- |
| 9(IS 7754) |
- |
0 |
|
- |
| 9(Microstructure) |
- |
0 |
|
- |
| 21(Marking) |
- |
100 |
|
- |
| 9(Microstructure) |
- |
0 |
|
- |
| 7.2(Casting dimensions) |
- |
0 |
|
- |
| Cl-6(Phosprorus (P) - IS 12308 ( P-5)) |
- |
500 |
|
Each element |
|
- |
- Included w.e.f 01.04.2026 |
| 1350 |
QUALITY INTERNATIONAL RESEARCH & LABORATORIES PRIVATE LIMITED
| 5197006
| IS 11513 (2017) |
Hot rolled carbon steel strip for cold rolling purposes - Specification (Second Revision) |
Hot Rolled Carbon Steel Strips |
9300 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl 8(Workmanship) |
- |
500 |
|
- |
| Cl 9(Length, Width, Thickness, Crown, Edge Camber & Difference in Thickness Across Width ) |
- |
500 |
|
- |
| Cl 8(Workmanship) |
- |
500 |
|
- |
| Cl 9(Length, Width, Thickness, Crown, Edge Camber & Difference in Thickness Across Width ) |
- |
500 |
|
- |
| Cl 8(Workmanship) |
- |
500 |
|
- |
| Cl 9(Length, Width, Thickness, Crown, Edge Camber & Difference in Thickness Across Width ) |
- |
500 |
|
- |
| 6.1(Carbon %) |
- |
500 |
|
- |
| 6.1(Manganese %) |
- |
500 |
|
- |
| 6.1(Phosphorus %) |
- |
500 |
|
- |
| 6.1(Sulphur %) |
- |
500 |
|
- |
| 6.1(Silicon %) |
- |
500 |
|
- |
| 6.1( Copper %) |
- |
500 |
|
- |
| 6.1( Aluminium %) |
- |
500 |
|
- |
| 6.1( Nb) |
- |
500 |
|
- |
| 6.1(V) |
- |
500 |
|
- |
| 6.1( Ti) |
- |
500 |
|
- |
| 6.1(Boron) |
- |
500 |
|
- |
| 6.1( Nitrogen%) |
- |
2500 |
|
- |
| 6.1(Microalloying) |
- |
500 |
|
- |
| 6.1(Carbon %) |
- |
500 |
|
- |
| 6.1(Manganese %) |
- |
500 |
|
- |
| 6.1(Phosphorus %) |
- |
500 |
|
- |
| 6.1(Sulphur %) |
- |
500 |
|
- |
| 6.1(Silicon %) |
- |
500 |
|
- |
| 6.1( Copper %) |
- |
500 |
|
- |
| 6.1( Aluminium %) |
- |
500 |
|
- |
| 6.1( Nb) |
- |
500 |
|
- |
| 6.1(V) |
- |
500 |
|
- |
| 6.1( Ti) |
- |
500 |
|
- |
| 6.1(Boron) |
- |
500 |
|
- |
| 6.1( Nitrogen%) |
- |
2500 |
|
- |
| 6.1(Microalloying) |
- |
500 |
|
- |
| 6.1(Carbon %) |
- |
500 |
|
- |
| 6.1(Manganese %) |
- |
500 |
|
- |
| 6.1(Phosphorus %) |
- |
500 |
|
- |
| 6.1(Sulphur %) |
- |
500 |
|
- |
| 6.1(Silicon %) |
- |
500 |
|
- |
| 6.1( Copper %) |
- |
500 |
|
- |
| 6.1( Aluminium %) |
- |
500 |
|
- |
| 6.1( Nb) |
- |
500 |
|
- |
| 6.1(V) |
- |
500 |
|
- |
| 6.1( Ti) |
- |
500 |
|
- |
| 6.1(Boron) |
- |
500 |
|
- |
| 6.1( Nitrogen%) |
- |
2500 |
|
- |
| 6.1(Microalloying) |
- |
500 |
|
- |
| Cl. 10(Weight) |
- |
500 |
|
- |
| Cl. 9.3(Crown) |
- |
500 |
|
- |
| Cl.9.3.1(Difference in Thickness) |
- |
500 |
|
- |
| Cl. 9.5(Edge Camber) |
- |
500 |
|
- |
| Cl.9(Thickness) |
- |
500 |
|
- |
| Cl.9(Width) |
- |
500 |
|
- |
| Cl 9(Length, Width, Thickness, Crown, Edge Camber & Difference in Thickness Across Width ) |
- |
500 |
|
- |
| Cl 8(Workmanship) |
- |
500 |
|
- |
| Cl 8(Workmanship) |
- |
500 |
|
- |
| Cl 9(Length, Width, Thickness, Crown, Edge Camber & Difference in Thickness Across Width) |
- |
500 |
|
- |
| 12(Marking) |
- |
500 |
|
- |
| Cl. 6.1 &6.2 Table 1,(Chromium) |
- |
500 |
|
- |
| Cl. 6.1 &6.2 Table 1,(Nb+Ti+B+V) |
- |
1500 |
|
- |
| Cl. 6.1 &6.2 Table 1,(Nickel) |
- |
500 |
|
- |
| Cl. 6.1 &6.2 Table 1,(Molybdenum) |
- |
500 |
|
- |
|
- |
- included w.e.f 09.03.2026 |