| 1291 |
Unique Test House LLP
| 9134536
| IS 1660 (2024) |
Wrought and Cast Aluminium Utensils Specification ( Second Revision ) |
ALL SIZES |
15000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl-3.1.1, 3.1.2(Minimum Thickness of Sheet) |
- |
200 |
|
........... |
| Cl-3.1.3, Table-2(Minimum Thickness at the Bottom) |
- |
200 |
|
........... |
| Cl-3.1.3, Table-2(Minimium Thickness of Wall at the Top Edge) |
- |
200 |
|
........... |
| Cl-3.1.3, Table-2(Minimum Cover Thickness) |
- |
200 |
|
......... |
| Cl-4.1(Main body of utensil) |
- |
200 |
|
....... |
| Cl-4.1(Cast cookware) |
- |
200 |
|
.......... |
| Cl-4.1(Other aluminum components and parts) |
- |
200 |
|
......... |
| Cl-4.1.1(Lids (material)) |
- |
200 |
|
......... |
| Cl-4.1.1(Minimum thickness of lid) |
- |
200 |
|
...... |
| Cl-4.1.2(Minimum thickness of glass) |
- |
200 |
|
....... |
| Cl-4.1.2(Material of rim) |
- |
200 |
|
...... |
| Cl-4.1.2(Minimum thickness of rim) |
- |
200 |
|
....... |
| Cl-4.2(Material of strips) |
- |
200 |
|
..... |
| Cl-4.2(Stainless steel handles, rivets and fittings) |
- |
200 |
|
...... |
| Cl-4.3(Clips of lunch box) |
- |
200 |
|
....... |
| Cl-4.3(Clips of lunch box) |
- |
200 |
|
...... |
| Cl-4.3(Rivets used in lunch box) |
- |
200 |
|
.......... |
| Cl-4.4(Screws, studs/nuts, and locking loop) |
- |
200 |
|
......... |
| Cl-4.5(Rivets for fixing of handles) |
- |
200 |
|
.......... |
| Cl-4.5(Material of cap) |
- |
200 |
|
.......... |
| Cl-4.6(Strips used for flame guards) |
- |
200 |
|
............ |
| Cl-4.6(stainless steel) |
- |
200 |
|
..... |
| Cl-5(Fabrication) |
- |
200 |
|
....... |
| Cl-6(Shape and Dimensions) |
- |
1000 |
|
.............. |
| Cl-7.1(Handles, when fitted) |
- |
200 |
|
........... |
| Cl-7.2(Handles) |
- |
200 |
|
................ |
| Cl-7.3 (Cl- 4.1 of IS 13395)(Construction) |
- |
200 |
|
................ |
| Cl-7.3 (Cl- 4.2 of IS 13395)(Materials) |
- |
200 |
|
................... |
| Cl-7.3 (Cl- 4.3 of IS 13395)(Selection and Size) |
- |
200 |
|
.................. |
| Cl-7.3 (Cl- 4.4 of IS 13395)(Position of Handle and Knob with Respect to Cookware) |
- |
200 |
|
................. |
| Cl-7.3 (Cl- 4.5 of IS 13395)(Attachment to Cookware) |
- |
200 |
|
................... |
| Cl-7.3 (Cl- 5.2 of IS 13395)(Bending Strength) |
- |
200 |
|
............ |
| Cl-7.3 (Cl- 5.3 of IS 13395)(Torque Strength) |
- |
200 |
|
................. |
| Cl-7.3 (Cl- 5.4 of IS 13395)(Impact Strength) |
- |
200 |
|
....................................... |
| Cl-7.3 (Cl- 5.5 of IS 13395)(Fatigue Resistance) |
- |
200 |
|
............................................... |
| Cl-7.3 (Cl- 5.6 of IS 13395)(Leakage) |
- |
200 |
|
.................................. |
| Cl-7.3 (Cl- 5.7 of IS 13395)(Thermal Insulation) |
- |
200 |
|
................................... |
| Wrought and Cast Aluminium Utensils — Specification(Heat Resistance) |
- |
200 |
|
........................... |
| Cl-7.3 (Cl- 5.9 of IS 13395)(Washing Resistance (Type Test)) |
- |
200 |
|
......................... |
| Cl-7.3 (Cl- 5.10 of IS 13395)(Burning Resistance) |
- |
200 |
|
.......................... |
| Cl-8(Workmanship and Finish) |
- |
200 |
|
............................ |
| Cl-8.3(Utensils, if anodized, fully or partially) |
- |
200 |
|
......................... |
| Cl-8.3(Minimum nominal thickness) |
- |
200 |
|
........................... |
| Cl-8.3(Thickness of hard anodized) |
- |
200 |
|
........................... |
| Cl-8.3(Finish and appearance of hard anodized) |
- |
200 |
|
.......................... |
| Cl-8.3(Abrasion resistance of hard anodized) |
- |
200 |
|
......................... |
| Cl-8.3(Colour of hard anodized) |
- |
200 |
|
............................ |
| Cl-8.3(Hardness of hard anodized) |
- |
200 |
|
.......................... |
| Wrought and Cast Aluminium Utensils — Specification(Lid of the cookware) |
- |
200 |
|
.......................... |
| Cl-8.5(Non-stick unreinforced PTFE) |
- |
200 |
|
................................ |
| Cl-8.6(Ceramic coating) |
- |
200 |
|
........................ |
| Cl-8.7(The thickness test, adhesion test) |
- |
200 |
|
......................... |
| Cl-8.7(Minimum thickness of coating) |
- |
200 |
|
........................ |
| Cl-8.7.1(Dry heat the cookware) |
- |
200 |
|
........................... |
| Cl-8.8(Requirements of PTFE) |
- |
200 |
|
............................ |
| Cl-8.9(Material for induction plate) |
- |
200 |
|
.......................... |
| Cl-8.9(Test for Induction compatible base) |
- |
200 |
|
.......................... |
| Cl-8.10.1(Tests for Lunch Boxes- Performance Test) |
- |
200 |
|
.......................... |
| Cl-8.10.1(Tests for Lunch Boxes- Performance Test) |
- |
200 |
|
......................... |
| Cl-8.10.2(Tests for Lunch Boxes- Ground Nut Oil Test for Leakage) |
- |
200 |
|
........................ |
| Cl-8.11.1(Test(s) on Tempered Glass Lid- Fragmentation Test) |
- |
200 |
|
......................... |
| Cl-8.11.2(Test(s) on Tempered Glass Lid-Ball Drop Test) |
- |
200 |
|
........................ |
| Cl-8.11.3(Test(s) on Tempered Glass Lid- Thermal Shock Test) |
- |
200 |
|
......................... |
| Cl-8.11.4(Test(s) on Tempered Glass Lid- Free Fall Test) |
- |
200 |
|
......................... |
| Cl-9.1(Normal Capacity) |
- |
200 |
|
....................... |
| Cl-9.2(Normal Capacity of internal diameter) |
- |
200 |
|
............................ |
| Cl 3.1.4 Table 3 (Amendment No.1)(Thickness of cast cookware- Cast Aluminium- Minimum Base Thickness of Body) |
- |
200 |
|
.............. |
|
07 Sep, 2028 |
- Included w.e.f 22.01.2026 |
| 1292 |
Standard Testing and Research Lab
| 9197206
| IS 1328 (2025) |
Veneered Decorative Plywood - Specification ( Fourth Revision ) |
All Grade |
4500 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl 4.1(Grades) |
- |
4500 |
|
- |
| Cl 4.2(Type) |
- |
4500 |
|
- |
| Cl 4.3(Formaldehyde Class) |
- |
4500 |
|
- |
| Cl 5.2(Adhesive) |
- |
4500 |
|
- |
| Cl 7.1(Surface Requirements- For Type 1) |
- |
4500 |
|
- |
| Cl 7.2(Surface Requirements- For Type 2) |
- |
4500 |
|
- |
| Cl 7.3(Surface Requirements- For Type 3) |
- |
4500 |
|
- |
| Cl 7.4(Surface Requirements- For Type 4) |
- |
4500 |
|
- |
| Cl 8.1(Dimensions (Length and Width)) |
- |
4500 |
|
- |
| Cl 8.2(Dimensions (Thickness)) |
- |
4500 |
|
- |
| Cl 8.3(Squareness and Edge Straightness as Per Annex B) |
- |
4500 |
|
- |
| Cl 8.4- Table 1(Tolerances) |
- |
4500 |
|
- |
| Cl 11.3(Moisture Content) |
- |
4500 |
|
- |
| Cl 11.4.1(a)(Water Resistance Test( For MR Grade)) |
- |
4500 |
|
- |
| Cl 11.4.1(b)(Water Resistance Test( For BWR Grade)) |
- |
4500 |
|
- |
| Cl 11.4.1(c)(Water Resistance Test( For BWP Grade)) |
- |
4500 |
|
- |
| Cl 11.5(Formaldehyde Content Test) |
- |
4500 |
|
- |
| Cl 12(Marking) |
- |
4500 |
|
- |
| Cl 11.6(Steady - State Formaldehyde Emission Test ( Optional Test)) |
- |
0 |
|
- |
|
24 Feb, 2029 |
- Exclusion: Cl 11.6 (Steady - State Formaldehyde Emission Test ( Optional Test)) |
| 1293 |
Standard Testing and Research Lab
| 9197206
| IS 303 (2024) |
Plywood for General Purposes â Specification (Fourth Revision) |
All Grades |
6000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl-5.1(Classification by appearance) |
- |
6000 |
|
- |
| Cl-5.2, Table- 1 (i)(Blister) |
- |
6000 |
|
- |
| Cl-5.2, Table- 1 (ii)(Checks) |
- |
6000 |
|
- |
| Cl-5.2, Table- 1 (iii)(Discolouration) |
- |
6000 |
|
- |
| Cl-5.2, Table- 1 (iv)(Dote) |
- |
6000 |
|
- |
| Cl-5.2, Table- 1 (v)(Insect hole) |
- |
6000 |
|
- |
| Cl-5.2, Table- 1 (vi)(Joints) |
- |
6000 |
|
- |
| Cl-5.2, Table- 1 (vii)(Knots (dead)) |
- |
6000 |
|
- |
| Cl-5.2, Table- 1 (viii)(Pin knots (dead)) |
- |
6000 |
|
- |
| Cl-5.2, Table- 1 (ix)(Pin knots (live)) |
- |
6000 |
|
- |
| Cl-5.2, Table- 1 (x)(Knots (tight)) |
- |
6000 |
|
- |
| Cl-5.2, Table- 1 (xi)(Patches) |
- |
6000 |
|
- |
| Cl-5.2, Table- 1 (xii)(Splits) |
- |
6000 |
|
- |
| Cl-5.2, Table- 1 (xiii)(Swirl) |
- |
6000 |
|
- |
| Cl-5.2, Table-2(Maximum Number of Categories of Permissible Defects, per m2) |
- |
6000 |
|
- |
| Cl-6.1(Timber) |
- |
6000 |
|
- |
| Cl-6.2(Adhesive) |
- |
6000 |
|
- |
| Cl-7.2.1(Thickness of veneers) |
- |
6000 |
|
- |
| Cl-7.2.3(Grain Direction) |
- |
6000 |
|
- |
| Cl-7.2.5.1(Gaps in cores and cross-bands) |
- |
6000 |
|
- |
| Cl-7.2.5.2(Splits) |
- |
6000 |
|
- |
| Cl-7.2.5.3(Overlap) |
- |
6000 |
|
- |
| Cl-8.1(Dimensions -length) |
- |
6000 |
|
- |
| Cl-8.2(Thickness of the plywood boards) |
- |
6000 |
|
- |
| Cl-8.3(Squareness) |
- |
6000 |
|
- |
| Cl-11.3.1, 11.3.1.1(Water Resistance Test) |
- |
6000 |
|
- |
| Cl-11.3.2(Mycological Test) |
- |
6000 |
|
- |
| Cl-11.4(Moisture Content) |
- |
6000 |
|
- |
| Cl-11.5, Table 4(Static Bending Strength - Modulus of Elasticity - Along the Face Grain - Average) |
- |
6000 |
|
- |
| Cl-11.5, Table 4(Static Bending Strength - Modulus of Elasticity - Along the Face Grain - Minimum Individual) |
- |
6000 |
|
- |
| Cl-11.6(Formaldehyde Content Test) |
- |
6000 |
|
- |
| Cl-11.7(Steady-State Formaldehyde Emission Test) |
- |
6000 |
|
- |
| Cl-9(WORKMANSHIP AND FINISH) |
- |
6000 |
|
- |
| Cl-7.2.4(Scarf Joints) |
- |
6000 |
|
- |
| Cl. 4(Grades) |
- |
6000 |
|
- |
| Cl.5.1(Type based on classification by appearance) |
- |
6000 |
|
- |
| Cl.5.2(Quality Requirements of Plywood for General Purposes) |
- |
6000 |
|
- |
| Cl.8.1(Dimensions -width) |
- |
6000 |
|
- |
| Cl.8, 8.3 & Annex C(Edge Straightness) |
- |
6000 |
|
- |
| Cl.8, 8.3 & Annex C(Edge Squareness) |
- |
6000 |
|
- |
| Cl-11.5, Table-4(Static Bending Strength - Modulus of Elasticity - Across the Face Grain - Average) |
- |
6000 |
|
- |
| Cl-11.5, Table-4,(Static Bending Strength - Modulus of Elasticity - Across the Face Grain - Minimum Individual) |
- |
6000 |
|
- |
| Cl-8.3(Edge Straightness) |
- |
6000 |
|
- |
| Cl-11.5, Table-4(Static Bending Strength - Modulus of Rupture - Along the Face Grain - Average) |
- |
6000 |
|
- |
| Cl-11.5, Table-4(Static Bending Strength - Modulus of Rupture - Along the Face Grain - Minimum Individual) |
- |
6000 |
|
- |
| Cl-11.5, Table-4(Static Bending Strength - Modulus of Rupture - Across the Face Grain - Average) |
- |
6000 |
|
- |
| Cl-11.5, Table-4(Static Bending Strength - Modulus of Rupture - Across the Face Grain - Minimum Individual) |
- |
6000 |
|
- |
| Cl-13(Marking) |
- |
6000 |
|
- |
|
24 Feb, 2029 |
- Exclusion: Cl-11.7 (Steady-State Formaldehyde Emission Test) |
| 1294 |
Standard Testing and Research Lab
| 9197206
| IS 710 (2024) |
MARINE PLYWOOD - SPECIFICATION (Third Revision) |
All Grade |
12000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl-4.1(Timber) |
- |
12000 |
|
- |
| Cl-4.2(Adhesive) |
- |
12000 |
|
- |
| Cl-5.1(Veneers) |
- |
12000 |
|
- |
| Cl-5.2.1(Glueing) |
- |
12000 |
|
- |
| Cl -5.2.2(Thickness of Veneers) |
- |
12000 |
|
- |
| Cl - 5.2.3.1(Joint in Veneers) |
- |
12000 |
|
- |
| Cl - 5.2.3.2(Edge joints) |
- |
12000 |
|
- |
| Cl - 5.2.3.3(End joints) |
- |
12000 |
|
- |
| Cl - 5.2.3.4(Scarf joints) |
- |
12000 |
|
- |
| Cl - 5.2.4(Grain Direction) |
- |
12000 |
|
- |
| Cl-5.3(Treatment) |
- |
12000 |
|
- |
| Cl-5.4(Moisture Content) |
- |
12000 |
|
- |
| Cl-6.1(Dimensions (length)) |
- |
12000 |
|
- |
| Cl-6.2(Thickness) |
- |
12000 |
|
- |
| Cl-6.3(Squareness) |
- |
12000 |
|
- |
| Cl-7.1, 7.2, 7.3, 7.4, 7.5 & 7.6(Workmanship and finish) |
- |
12000 |
|
- |
| Cl-9.3(Moisture Content) |
- |
12000 |
|
- |
| Cl-9.4.2(Glue Adhesion in Dry State- Adhesion of Plies) |
- |
12000 |
|
- |
| Cl-9.4.1(Glue Adhesion in Dry State- Glue Shear Strength -Average) |
- |
12000 |
|
- |
| Cl-9.5.1.1(Glue Adhesion in Water Resistance - Glue Shear Strength -Average) |
- |
12000 |
|
- |
| Cl-9.5.1.2(Water Resistance Test-Adhesion of plies) |
- |
12000 |
|
- |
| Cl-9.5.2(Water Resistance Test) |
- |
12000 |
|
- |
| Cl-9.6(Tensile Strength-Along the grain) |
- |
12000 |
|
- |
| Cl-9.7(Mycological Test -Adhesion) |
- |
12000 |
|
- |
| Cl-9.8, Table-2(Static Bending Strength - Modulus of Elasticity - Along the Face Grain - Average) |
- |
12000 |
|
- |
| Cl-9.8, Table-2(Static Bending Strength - Modulus of Elasticity - Along the Face Grain - Minimum Individual) |
- |
12000 |
|
- |
| Cl-9.9, Table-3 (i) a((Modulus of Elasticity: Across the Face Grain: Average) Wet Bending) |
- |
12000 |
|
- |
| Cl-9.9, Table-3 (i) b((Modulus of Elasticity: Across the Face Grain: Minimum Individual) Wet Bending) |
- |
12000 |
|
- |
| Cl-9.10(Retention of Preservative) |
- |
0 |
|
- |
| Cl-9.11(Formaldehyde Content Test) |
- |
12000 |
|
- |
| Cl-9.12(Steady-State Formaldehyde Emission Test) |
- |
0 |
|
- |
| Cl-9.4.2(Adhesion of Plies) |
- |
12000 |
|
- |
| 5.1.1(Defects in veneers) |
- |
12000 |
|
- |
| Cl-9.8, Table-2(Static Bending Strength - Modulus of Elasticity - Across the Face Grain - Average) |
- |
12000 |
|
- |
| Cl-9.8, Table-2(Static Bending Strength - Modulus of Elasticity - Across the Face Grain - Minimum Individual) |
- |
12000 |
|
- |
| Cl-9.9, Table-3 (ii) a((Modulus of Rupture: Across the Face Grain: Average) Wet Bending) |
- |
12000 |
|
- |
| Cl-9.9, Table-3 (ii) b((Modulus of Rupture: Across the Face Grain: Minimum Individual) Wet Bending) |
- |
12000 |
|
- |
| Cl-6.1(Dimensions (width)) |
- |
12000 |
|
- |
| Cl-8.3(Edge Straightness) |
- |
12000 |
|
- |
| Cl-9.4.1(Glue Adhesion in Dry State- Glue Shear Strength –Minimum Individual) |
- |
12000 |
|
- |
| Cl-9.5.1.1(Glue Adhesion in Water Resistance - Glue Shear Strength –Minimum Individual) |
- |
12000 |
|
- |
| Cl-9.6(Tensile Strength-Across the grain) |
- |
12000 |
|
- |
| Cl-9.7(Glue Adhesion in Mycological test - Glue Shear Strength –Minimum Individual) |
- |
12000 |
|
- |
| Cl-9.7(Glue Adhesion in Mycological test - Glue Shear Strength -Average) |
- |
12000 |
|
- |
| Cl-9.8, Table-2(Static Bending Strength - Modulus of Rupture - Along the Face Grain - Average) |
- |
12000 |
|
- |
| Cl-9.8, Table-2(Static Bending Strength - Modulus of Rupture - Along the Face Grain - Minimum Individual) |
- |
12000 |
|
- |
| Cl-9.8, Table-2(Static Bending Strength - Modulus of Rupture - Across the Face Grain - Minimum Individual) |
- |
12000 |
|
- |
| Cl-9.8, Table-2(Static Bending Strength - Modulus of Rupture - Across the Face Grain - Average) |
- |
12000 |
|
- |
| Cl-11.1(Marking) |
- |
12000 |
|
- |
| Cl-11.3(Marking) |
- |
12000 |
|
- |
|
24 Feb, 2029 |
- Exclusion: Cl-9.12 (Steady-State Formaldehyde Emission Test) |
| 1295 |
Standard Testing and Research Lab
| 9197206
| IS 4990 (2024) |
PLYWOOD FOR CONCRETE SHUTTERING WORKS SPECIFICATION (Fourth Revision) |
All Grade |
14000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl-5.1(Timber) |
- |
14000 |
|
- |
| Cl-5.2(Adhesives for Bonding of Veneers) |
- |
14000 |
|
- |
| Cl-6.1(Manufacture) |
- |
14000 |
|
- |
| Cl-6.2(Manufacture ( Thickness of veneers)) |
- |
14000 |
|
- |
| Cl-6.3(Manufacture ( Physical and mechanical properties of veneers)) |
- |
14000 |
|
- |
| Cl-6.4, 6.7(Manufacture (Plywood for concrete shuttering)) |
- |
14000 |
|
- |
| Cl-6.5(Manufacture (Scarf joints)) |
- |
14000 |
|
- |
| Cl-6.6(Manufacture ( Preservative treatment)) |
- |
14000 |
|
- |
| Cl-7.1(Dimensions -length) |
- |
14000 |
|
- |
| Cl-7.2(Thickness) |
- |
14000 |
|
- |
| Cl-7.3(Squareness) |
- |
14000 |
|
- |
| Cl-8.1, 8.2(Workmanship and finish) |
- |
14000 |
|
- |
| Cl-10.3(Moisture Content) |
- |
14000 |
|
- |
| Cl-10.4.1(Glue Adhesion in Dry State - Glue Shear Strength-WOOD FAILURE, Average) |
- |
14000 |
|
- |
| Cl-10.4.2(Glue Adhesion in Dry State - Adhesion of Plies) |
- |
14000 |
|
- |
| Cl-10.5, 10.5.1(Resistance to water test- glue shear strength- WOOD Failure, Average) |
- |
14000 |
|
- |
| Cl-10.5.1.1(Water Resistance Test-Glue shear strength) |
- |
14000 |
|
- |
| Cl-10.5.1.2(Water Resistance Test-Adhesion of plies) |
- |
14000 |
|
- |
| Cl-10.5.2(Water Resistance Test (Alternate method)) |
- |
14000 |
|
- |
| Cl-10.6(Water resistance test (Concrete shuttering Plywood)) |
- |
14000 |
|
- |
| Cl-10.7.1, Table-2(Mycological Test- Glue shear strengt) |
- |
14000 |
|
- |
| Cl-10.7.2(Mycological Test- Adhesion of plies) |
- |
14000 |
|
- |
| Cl-10.8(Tensile Strength) |
- |
14000 |
|
- |
| Cl-10.9, Table-3 (i)(Along (parallel to the grain direction of the face veneer)) |
- |
14000 |
|
- |
| Cl-10.9, Table-3 (ii)(Across (perpendicular to the grain direction of the face veneer)) |
- |
14000 |
|
- |
| Cl-10.10, Table-4 (i) a((Modulus of Elasticity: Across the Face Grain: Average) Wet Bending) |
- |
14000 |
|
- |
| Cl-10.10, Table-4 (i) b((Modulus of Rupture: Across the Face Grain: Minimum Individual) Wet Bending) |
- |
14000 |
|
- |
| Cl-10.11(Retention of Preservative) |
- |
14000 |
|
- |
| Cl-10.12(Formaldehyde Content Test) |
- |
14000 |
|
- |
| Cl-10.13(Steady-State Formaldehyde Emission Test) |
- |
14000 |
|
- |
| Cl-10.10, Table-4 (ii) a(Wet Bending Strength:-
Modulus of Rupture: Across the Face Grain: Average)) |
- |
14000 |
|
- |
| Cl-10.10, Table-4, (ii) b(Wet Bending Strength;
(Modulus of Rupture: Along the Face Grain: Minimum Individual)) |
- |
14000 |
|
- |
| Cl-10.4.1, 10.5.1.1 and 10.7.1, Table-2(Average Wood Failure) |
- |
14000 |
|
- |
| Cl-10.4.1, 10.5.1.1 and 10.7.1, Table-2(Average Failure Load, N -Dry State) |
- |
14000 |
|
- |
| Cl-10.4.1, 10.5.1.1 and 10.7.1, Table-2(Average Failure Load, N- Resistance to Water) |
- |
14000 |
|
- |
| Cl-10.4.1, 10.5.1.1 and 10.7.1, Table-2(Average Failure Load, N - Resistance to Micro-Organisms) |
- |
14000 |
|
- |
| Cl-10.8 (a)(Tensile strength) |
- |
14000 |
|
- |
| Cl-10.8 (b)(Tensile strength) |
- |
14000 |
|
- |
| Cl-10.8 (c)(Tensile strengths in both directions) |
- |
14000 |
|
- |
| Cl-7.1(Dimensions (width)) |
- |
14000 |
|
- |
| Cl-7.3(Edge Straightness) |
- |
14000 |
|
- |
|
24 Feb, 2029 |
- Exclusion: Cl-10.13 (Steady-State Formaldehyde Emission Test) |
| 1296 |
Unique Test House LLP
| 9134536
| IS 6083 (1971) |
Specification for table, obstetric, labour |
ALL SIZES |
12000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 2.1(Tube) |
- |
1000 |
|
............ |
| 2.2(Top) |
- |
1500 |
|
.......... |
| 2.3(Channel Support) |
- |
1500 |
|
........... |
| 2.4(Lithotomy Rods) |
- |
2000 |
|
.............. |
| 3(Shape s and Dimension) |
- |
4700 |
|
........ |
| 4(Manufacture) |
- |
200 |
|
... |
| 5(Finish) |
- |
200 |
|
...... |
| 6(Adhesion Test) |
- |
500 |
|
..... |
| 7(Marking) |
- |
200 |
|
.... |
| 8(Packing) |
- |
200 |
|
............. |
|
07 Sep, 2028 |
- Included w.e.f 22.01.2026 |
| 1297 |
MORBI TEST HOUSE LLP
| 7195306
| IS 303 (2024) |
Plywood for General Purposes â Specification (Fourth Revision) |
All Grade / Type / Size / Designation |
10700 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl-5.1(Classification by appearance) |
- |
100 |
|
- |
| Cl-5.2, Table- 1 (i)(Blister) |
- |
50 |
|
- |
| Cl-5.2, Table- 1 (ii)(Checks) |
- |
50 |
|
- |
| Cl-5.2, Table- 1 (iii)(Discolouration) |
- |
50 |
|
- |
| Cl-5.2, Table- 1 (iv)(Dote) |
- |
50 |
|
- |
| Cl-5.2, Table- 1 (v)(Insect hole) |
- |
50 |
|
- |
| Cl-5.2, Table- 1 (vi)(Joints) |
- |
50 |
|
- |
| Cl-5.2, Table- 1 (vii)(Knots (dead)) |
- |
50 |
|
- |
| Cl-5.2, Table- 1 (viii)(Pin knots (dead)) |
- |
50 |
|
- |
| Cl-5.2, Table- 1 (ix)(Pin knots (live)) |
- |
50 |
|
- |
| Cl-5.2, Table- 1 (x)(Knots (tight)) |
- |
50 |
|
- |
| Cl-5.2, Table- 1 (xi)(Patches) |
- |
50 |
|
- |
| Cl-5.2, Table- 1 (xii)(Splits) |
- |
50 |
|
- |
| Cl-5.2, Table- 1 (xiii)(Swirl) |
- |
50 |
|
- |
| Cl-5.2, Table-2(Maximum Number of Categories of Permissible Defects, per m2) |
- |
50 |
|
- |
| Cl-6.1(Timber) |
- |
50 |
|
- |
| Cl-6.2(Adhesive) |
- |
4000 |
|
- |
| Cl-7.2.1(Thickness of veneers) |
- |
50 |
|
- |
| Cl-7.2.3(Grain Direction) |
- |
50 |
|
- |
| Cl-7.2.5.1(Gaps in cores and cross-bands) |
- |
50 |
|
- |
| Cl-7.2.5.2(Splits) |
- |
50 |
|
- |
| Cl-7.2.5.3(Overlap) |
- |
50 |
|
- |
| Cl-8.1(Dimensions -length) |
- |
500 |
|
- |
| Cl-8.2(Thickness of the plywood boards) |
- |
500 |
|
- |
| Cl-8.3(Squareness) |
- |
1000 |
|
- |
| Cl-11.3.1, 11.3.1.1(Water Resistance Test) |
- |
1000 |
|
- |
| Cl-11.3.2(Mycological Test) |
- |
2500 |
|
- |
| Cl-11.4(Moisture Content) |
- |
1000 |
|
- |
| Cl-11.5, Table 4(Static Bending Strength - Modulus of Elasticity - Along the Face Grain - Average) |
- |
1500 |
|
- |
| Cl-11.5, Table 4(Static Bending Strength - Modulus of Elasticity - Along the Face Grain - Minimum Individual) |
- |
1500 |
|
- |
| Cl-11.6(Formaldehyde Content Test) |
- |
2500 |
|
- |
| Cl-9(WORKMANSHIP AND FINISH) |
- |
50 |
|
- |
| Cl-7.2.4(Scarf Joints) |
- |
50 |
|
- |
| Cl. 4(Grades) |
- |
50 |
|
- |
| Cl.5.1(Type based on classification by appearance) |
- |
100 |
|
- |
| Cl.5.2(Quality Requirements of Plywood for General Purposes) |
- |
50 |
|
- |
| Cl.8.1(Dimensions -width) |
- |
500 |
|
- |
| Cl.8, 8.3 & Annex C(Edge Straightness) |
- |
500 |
|
- |
| Cl.8, 8.3 & Annex C(Edge Squareness) |
- |
500 |
|
- |
| Cl-11.5, Table-4(Static Bending Strength - Modulus of Elasticity - Across the Face Grain - Average) |
- |
1500 |
|
- |
| Cl-11.5, Table-4,(Static Bending Strength - Modulus of Elasticity - Across the Face Grain - Minimum Individual) |
- |
1500 |
|
- |
| Cl-8.3(Edge Straightness) |
- |
500 |
|
- |
| Cl-11.5, Table-4(Static Bending Strength - Modulus of Rupture - Along the Face Grain - Average) |
- |
1500 |
|
- |
| Cl-11.5, Table-4(Static Bending Strength - Modulus of Rupture - Along the Face Grain - Minimum Individual) |
- |
1500 |
|
- |
| Cl-11.5, Table-4(Static Bending Strength - Modulus of Rupture - Across the Face Grain - Average) |
- |
1500 |
|
- |
| Cl-11.5, Table-4(Static Bending Strength - Modulus of Rupture - Across the Face Grain - Minimum Individual) |
- |
1500 |
|
- |
| Cl-13(Marking) |
- |
50 |
|
- |
|
- |
- Included w.e.f. 22.01.2026
Exclusion: Cl-11.7 (Steady-State Formaldehyde Emission Test) |
| 1298 |
Standard Testing and Research Lab
| 9197206
| IS 1659 (2004) |
Block boards - Specification (Fourth Revision) |
All Grade |
6000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 9.2.6(Spot test - Annexure L) |
- |
6000 |
|
- |
| 9.2.5(Modulus of elasticity - MINIMUM INDIVIDUAL - Annexure K) |
- |
6000 |
|
- |
| 9.2.5(Modulus of elasticity - AVERAGE - Annexure K) |
- |
6000 |
|
- |
| 9.2.5(Modulus of rupture - MINIMUM INDIVIDUAL - Annexure K) |
- |
6000 |
|
- |
| 9.2.5(Modulus of rupture - AVERAGE - Annexure K) |
- |
6000 |
|
- |
| 9.2.4(Mycological Test [for MR grade only] - Annexure J) |
- |
6000 |
|
- |
| 9.2.3(Adhesion of Plies - Annexure H) |
- |
6000 |
|
- |
| 9.2.2 (Resistance to water - Annexure G, Annexure H [For MR Grade]) |
- |
6000 |
|
- |
| 9.2.2 (Resistance to water - Annexure G, Annexure H [For BWP grade]) |
- |
6000 |
|
- |
| 9.2.1(Dimensional Changes caused by humidity Change in local planeness - Annexure F) |
- |
6000 |
|
- |
| 9.2.1(Dimensional Changes caused by humidity - Delamination - Annexure F) |
- |
6000 |
|
- |
| 9.2.1(Dimensional Changes caused by humidity - Change in thickness - at 40% RH - Annexure F) |
- |
6000 |
|
- |
| 9.2.1(Dimensional Changes caused by humidity - Change in Thickness - at 90% RH - Annexure F) |
- |
6000 |
|
- |
| 9.2.1(Dimensional Changes caused by humidity - Change in Length - at 40% RH - Annexure F) |
- |
6000 |
|
- |
| 9.2.1(Dimensional Changes caused by humidity - Change in Length - at 90% RH - Annexure F) |
- |
6000 |
|
- |
| 7.3(Dimensional Requirements - Variation in thickness - Annexure E) |
- |
6000 |
|
- |
| 7.3(Dimensional Requirements - Squareness - Annexure D) |
- |
6000 |
|
- |
| 7.3(Dimensional Requirements - Edge Straightness - Annexure D) |
- |
6000 |
|
- |
| 7.3(Dimensional Requirements - Thickness - Annexure E) |
- |
6000 |
|
- |
| 7.3(Dimensional Requirements - Width - 8.1.4) |
- |
6000 |
|
- |
| 7.3(Dimensional Requirements - Length - 8.1.4) |
- |
6000 |
|
- |
| 8.1.3, 6.3.3, IS 1328(Visual Inspection - Permissible Defects - IS 1328 [test method for DECORATIVE type]) |
- |
6000 |
|
- |
| 8.1.3, 6.3.3, IS 303(Visual Inspection - Permissible Defects - IS 303 [test method for COMMERCIAL type]) |
- |
6000 |
|
- |
| 9.2.6 (mechanical)(Spot test - Annexure L) |
- |
6000 |
|
- |
| cl. 11(marking) |
- |
6000 |
|
- |
| cl. 11.1(marking - BIS certification marking) |
- |
6000 |
|
- |
| Cl-10(ADDITIONAL REQUIREMENTS FOR
ECO-MARK) |
- |
6000 |
|
- |
| 6.2(Core- Moisture & Width) |
- |
6000 |
|
- |
| 6.3(Cross Bands and Faces- Moisture content) |
- |
6000 |
|
- |
| 6.3.1(Thickness of cross band and face veneers) |
- |
6000 |
|
- |
| Cl-7.1(Thickness) |
- |
6000 |
|
- |
| Cl-7.2(Sizes) |
- |
6000 |
|
- |
|
24 Feb, 2029 |
- Exclusion: Except additional requirement for eco-mark test |
| 1299 |
JBS TESTING SOLUTIONS PVT LTD (27), JALANDHAR
| 9164606
| IS 2681 (1993) |
Non - Ferrous metal sliding door bolts (Aldrops) for use with padlocks - Specification (Third Revision) |
- |
24400 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl. 8.1(Brass sliding door bolts shall have satin
finish or shall be polished or plated as specified by the purchaser) |
- |
1000 |
|
- |
| Cl. 8.2 (Ref. Cl. 11.1 of IS 1868:1996)( appearance and Colour - shall be free from visible defects on the significant surface(s) when viewed from an agreed distance) |
- |
2000 |
|
- |
| Cl. 8.2 (Ref. Cl.9 of IS 1868:1996)(Aluminium shall be anodized to a bright,
natural, sat or satin finish or dyed. ) |
- |
2000 |
|
- |
| Cl. 8.2 (Ref. Cl.9 of IS 1868:1996)(Anodinc casting thickness (Cl. 9.2 of IS 1868:1996)) |
- |
2000 |
|
- |
| 3(TYPES) |
- |
500 |
|
- |
| 4(SIZES) |
- |
500 |
|
- |
| 6.1-Total 2(DIMENSIONS AND TOLERANCES-A) |
- |
300 |
|
- |
| 6.1-Total 2(DIMENSIONS AND TOLERANCES-B) |
- |
300 |
|
- |
| 6.1-Total 2(DIMENSIONS AND TOLERANCES-C) |
- |
300 |
|
- |
| 6.1-Total 2(DIMENSIONS AND TOLERANCES-D) |
- |
300 |
|
- |
| 6.1-Total 2(DIMENSIONS AND TOLERANCES-E) |
- |
300 |
|
- |
| 6.1-Total 2(DIMENSIONS AND TOLERANCES-F) |
- |
300 |
|
- |
| 6.1-Total 2(DIMENSIONS AND TOLERANCES-G) |
- |
300 |
|
- |
| 6.1-Total 2(DIMENSIONS AND TOLERANCES-H) |
- |
300 |
|
- |
| 6.1-Total 2(DIMENSIONS AND TOLERANCES-J) |
- |
300 |
|
- |
| 6.1-Total 2(DIMENSIONS AND TOLERANCES-K) |
- |
300 |
|
- |
| 6.1-Total 2(DIMENSIONS AND TOLERANCES-L) |
- |
300 |
|
- |
| 6.1-Total 2(DIMENSIONS AND TOLERANCES-M) |
- |
300 |
|
- |
| 6.1-Total 2(DIMENSIONS AND TOLERANCES-N) |
- |
300 |
|
- |
| 6.1-Total 2(DIMENSIONS AND TOLERANCES-Q) |
- |
300 |
|
- |
| 6.1-Total 2(DIMENSIONS AND TOLERANCES-S) |
- |
300 |
|
- |
| 6.1-Total 2(DIMENSIONS AND TOLERANCES-T) |
- |
300 |
|
- |
| 6.1-Total 2(DIMENSIONS AND TOLERANCES-W) |
- |
300 |
|
- |
| 6.1-Total 2(DIMENSIONS AND TOLERANCES-No. of Screw on Staple or Clip to accommodate Wood Screw N0 8) |
- |
1000 |
|
- |
| 6.1-Table 3(DIMENSIONS AND TOLERANCES-A) |
- |
300 |
|
- |
| 6.1-Table 3(DIMENSIONS AND TOLERANCES-B) |
- |
300 |
|
- |
| 6.1-Table 3(DIMENSIONS AND TOLERANCES-C) |
- |
300 |
|
- |
| 6.1-Table 3(DIMENSIONS AND TOLERANCES-D) |
- |
300 |
|
- |
| 6.1-Table 3(DIMENSIONS AND TOLERANCES-E) |
- |
300 |
|
- |
| 6.1-Table 3(DIMENSIONS AND TOLERANCES-F) |
- |
300 |
|
- |
| 6.1-Table 3(DIMENSIONS AND TOLERANCES-G) |
- |
300 |
|
- |
| 6.1-Table 3(DIMENSIONS AND TOLERANCES-H) |
- |
300 |
|
- |
| 6.1-Table 3(DIMENSIONS AND TOLERANCES-J) |
- |
300 |
|
- |
| 6.1-Table 3(DIMENSIONS AND TOLERANCES-K) |
- |
300 |
|
- |
| 6.1-Table 3(DIMENSIONS AND TOLERANCES-L) |
- |
300 |
|
- |
| 6.1-Table 3(DIMENSIONS AND TOLERANCES-M) |
- |
300 |
|
- |
| 6.1-Table 3(DIMENSIONS AND TOLERANCES-Pin dia) |
- |
300 |
|
- |
| 6.1-Table 3(DIMENSIONS AND TOLERANCES-R) |
- |
300 |
|
- |
| 6.1-Table 3(DIMENSIONS AND TOLERANCES-T) |
- |
300 |
|
- |
| 6.1-Table 3(DIMENSIONS AND TOLERANCES-U) |
- |
300 |
|
- |
| 6.1-Table 3(DIMENSIONS AND TOLERANCES-No. of Screw on Staple or Clip to accommodate Wood Screw N0 8) |
- |
1000 |
|
- |
| 7.1(MANUFACTURE-General) |
- |
400 |
|
- |
| 7.1(MANUFACTURE-General) |
- |
400 |
|
- |
| 7.1(MANUFACTURE-General) |
- |
400 |
|
- |
| 7.1(MANUFACTURE-General) |
- |
400 |
|
- |
| 7.1(MANUFACTURE-General) |
- |
400 |
|
- |
| 7.2(MANUFACTURE-Brass Sliding Door Bolts or Aluminium Alloy
Sliding Door Bolts) |
- |
500 |
|
- |
| 7.2(MANUFACTURE-Brass Sliding Door Bolts or Aluminium Alloy
Sliding Door Bolts) |
- |
499.97 |
|
- |
| 8.1(FINISH) |
- |
800 |
|
- |
| 8.2(FINISH) |
- |
800 |
|
- |
| 8.2(FINISH-anodic casting -Min Avg thickness) |
- |
1600 |
|
- |
| 8.2(FINISH-anodic casting -Min Local thickness) |
- |
1600 |
|
- |
| 7.2(Brass/Aluminium alloy door bolt) |
- |
500 |
|
- |
| 7.2(Aluminium alloy door bolt) |
- |
500 |
|
- |
| 7.1(General) |
- |
500 |
|
- |
| 6.1 Fig 1(Dimensions & Tolerances) |
- |
300 |
|
- |
| 6.1 Fig 1(Dimensions & Tolerances) |
- |
300 |
|
- |
| 6.1 Fig 1(Dimensions & Tolerances) |
- |
300 |
|
- |
| 6.1 Fig 1(Dimensions & Tolerances) |
- |
299.99 |
|
- |
| 6.1 Fig 1(Dimensions & Tolerances) |
- |
300 |
|
- |
| 6.1 Fig 1(Dimensions & Tolerances) |
- |
300 |
|
- |
| 6.1 Fig 1(Dimensions & Tolerances) |
- |
300 |
|
- |
| 6.1 Fig 1(Dimensions & Tolerances) |
- |
300 |
|
- |
| 6.1 Fig 1(Dimensions & Tolerances) |
- |
300 |
|
- |
| 6.1 Fig 1(Dimensions & Tolerances) |
- |
300 |
|
- |
| 6.1 Fig 1 & Table 3(Dimensions & Tolerances) |
- |
300 |
|
- |
| 6.1 Fig 1 & Table 3(Dimensions & Tolerances) |
- |
300 |
|
- |
| 6.1 Fig 1 & Table 3(Dimensions & Tolerances) |
- |
300 |
|
- |
| 6.1 Fig 1 & Table 3(Dimensions & Tolerances) |
- |
300 |
|
- |
| 6.1 Fig 1 & Table 3(Dimensions & Tolerances) |
- |
300 |
|
- |
| 6.1 Fig 1 & Table 3(Dimensions & Tolerances) |
- |
300 |
|
- |
| 6.1 Fig 1 & Table 3(Dimensions & Tolerances) |
- |
300 |
|
- |
| 6.1 Fig 1 & Table 3(Dimensions & Tolerances) |
- |
300 |
|
- |
| 6.1 Fig 1 & Table 3(Dimensions & Tolerances) |
- |
300 |
|
- |
| 6.1 Fig 1 & Table 3(Dimensions & Tolerances) |
- |
300 |
|
- |
| 6.1 Fig 1 & Table 3(Dimensions & Tolerances) |
- |
300 |
|
- |
| 6.1 Fig 1 & Table 3(Dimensions & Tolerances) |
- |
300 |
|
- |
| 6.1 Fig 1 & Table 3(Dimensions & Tolerances) |
- |
300 |
|
- |
| 6.1 Fig 1 & Table 3(Dimensions & Tolerances) |
- |
300 |
|
- |
| 6.1 Fig 1 & Table 3(Dimensions & Tolerances) |
- |
300 |
|
- |
| 6.1 Fig 1 & Table 3(Dimensions & Tolerances) |
- |
300 |
|
- |
| 6.1 Fig 1 & Table 3(Dimensions & Tolerances) |
- |
300 |
|
- |
| 4.0(Sizes) |
- |
300 |
|
- |
| 3.1(Sliding Door Bolts) |
- |
300 |
|
- |
|
- |
- Included w.e.f 22.01.2026 |
| 1300 |
SGS India Pvt Ltd, Gurgaon (8136216)
| 8136216
| IS 17634 (2022) |
Storage Units - Specification |
Storage Units - Specification |
32000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| CLAUSE 5(DIMENSIONS) |
- |
1000 |
|
- |
| CLAUSE 6(SURFACE PERFORMANCE) |
- |
0 |
|
CLAUSE WISE RATES GIVEN IN NEXT PARAMETERS |
| CLAUSE 6.2(Fabric and Leather (Synthetic and Natural) Performance) |
- |
0 |
|
CLAUSE WISE RATES GIVEN IN NEXT PARAMETERS |
| CLAUSE 7.1(SAFETY TESTS (General)) |
- |
800 |
|
- |
| CLAUSE 7.2(Test for Non-Movable Parts) |
- |
800 |
|
- |
| Cl-6.1 (a)(Resistance to mechanical damage) |
- |
0 |
|
Parameter removed in Amendment 01 -20251 |
| Cl-6.1 (b)(Pencil hardness) |
- |
1000 |
|
- |
| Cl-6.1 (c)(Resistance to wet heat) |
- |
1500 |
|
- |
| Cl-6.1 (d)Cl-6.1 (d)(Resistance to dry heat) |
- |
1500 |
|
- |
| Cl-6.1 (e)(Resistance to marking by cold liquids) |
- |
2000 |
|
- |
| Cl-6.1 (f)(Resistance to marking by cold oils and fats
Resistance to marking by cold oils and fats) |
- |
2000 |
|
- |
| Cl-6.1 (g)(Adhesive performance) |
- |
1500 |
|
- |
| Cl-6.2 (a) 1(Breaking load) |
- |
1000 |
|
- |
| Cl-6.2 (a) 2(Elongation at break) |
- |
1000 |
|
- |
| Cl-6.2 (a) 3(Tear strength) |
- |
1000 |
|
- |
| Cl-6.2 (a) 4(Colour fastness to light) |
- |
500 |
|
- |
| Cl-6.2 (a) 5(Colour fastness to rubbing) |
- |
1500 |
|
- |
| Cl-6.2 (a) 6(Colour fastness to perspiration) |
- |
500 |
|
- |
| Cl-6.2 (a) 7(Colour fastness to water) |
- |
500 |
|
- |
| Cl-6.2 (a) 8(Pilling resistance) |
- |
500 |
|
- |
| Cl-6.2 (a) 9(Coating adhesion strength) |
- |
1000 |
|
- |
| Cl-6.2 (a) 10(Seam slippage) |
- |
1000 |
|
- |
| Cl-6.2 (a) 11(Resistance to damage by flexing) |
- |
1000 |
|
- |
| Cl-6.2 (a) 12(Abrasion resistance) |
- |
1500 |
|
- |
| Cl-6.2 (a) 13(Bursting strength) |
- |
1000 |
|
- |
| Cl-6.2 (a) 14(Resistance to cold) |
- |
1500 |
|
- |
| Cl-6.2 (b) 1(Tear strength) |
- |
1500 |
|
- |
| Cl-6.2 (b) 2(Flexing endurance) |
- |
500 |
|
- |
| Cl-6.2 (b) 3(Finish adhesion) |
- |
1500 |
|
- |
| Cl-6.2 (b) 4(Colour fastness to artificial light) |
- |
1000 |
|
- |
| Cl-6.2 (b) 5(Colour fastness to rubbing) |
- |
1500 |
|
- |
| Cl-6.2 (b) 6(Colour fastness to water spotting) |
- |
1000 |
|
- |
| Cl-6.2 (b) 7(Water vapour permeability) |
- |
500 |
|
- |
| Cl-6.2 (b) 8(Colour fastness to water) |
- |
1500 |
|
- |
| CLAUSE 7.2.1(Shelves) |
- |
800 |
|
- |
| CLAUSE 7.2.1.2(Deflection of shelves) |
- |
800 |
|
- |
| CLAUSE 7.2.2.1(Sustained load test for tops and bottoms) |
- |
800 |
|
- |
| CLAUSE 7.2.2.2(Static load test for tops and bottoms) |
- |
800 |
|
- |
| CLAUSE 7.2.3.1(Strength of clothes-rail supports) |
- |
800 |
|
- |
| CLAUSE 7.2.3.2(Dislodgement of clothes rail) |
- |
800 |
|
- |
| CLAUSE 7.2.4.2(Drop test) |
- |
800 |
|
- |
| CLAUSE 7.2.4.3(Tests for units with castors or wheels) |
- |
800 |
|
- |
| CLAUSE 7.3.1(Pivoted Doors) |
- |
0 |
|
CLAUSE WISE RATES GIVEN IN NEXT PARAMETERS |
| CLAUSE 7.3.1.2.1(Vertical load on pivoted door) |
- |
800 |
|
- |
| CLAUSE 7.3.1.2.2(Horizontal load on pivoted door) |
- |
800 |
|
- |
| CLAUSE 7.3.1.3(Slam-shut test of pivoted doors) |
- |
800 |
|
- |
| CLAUSE 7.3.1.4(Durability of pivoted doors) |
- |
800 |
|
- |
| CLAUSE 7.3.2(Sliding Doors and Horizontal Roll-fronts) |
- |
0 |
|
CLAUSE WISE RATES GIVEN IN NEXT PARAMETERS |
| CLAUSE 7.3.2.2(Slam shut/open test of sliding doors and horizontal roll-fronts) |
- |
800 |
|
- |
| CLAUSE 7.3.2.3(Durability of sliding doors and horizontal roll-fronts) |
- |
800 |
|
- |
| CLAUSE 7.3.3(Flaps) |
- |
0 |
|
CLAUSE WISE RATES GIVEN IN NEXT PARAMETERS |
| CLAUSE 7.3.3.1(Strength of bottom-hinged flaps) |
- |
800 |
|
- |
| CLAUSE 7.3.3.2(Durability of flaps) |
- |
800 |
|
- |
| CLAUSE 7.3.3.3(Drop test for top-hinged flaps) |
- |
800 |
|
- |
| CLAUSE 7.3.4(Vertical Roll-Fronts) |
- |
0 |
|
CLAUSE WISE RATES GIVEN IN NEXT PARAMETERS |
| CLAUSE 7.3.4.1(Slam shut/open test of vertical roll-fronts) |
- |
800 |
|
- |
| CLAUSE 7.3.4.2(Durability of vertical roll-fronts) |
- |
800 |
|
- |
| CLAUSE 7.3.5(Extension Element) |
- |
0 |
|
CLAUSE WISE RATES GIVEN IN NEXT PARAMETERS |
| CLAUSE 7.3.5.2(Strength of extension elements) |
- |
800 |
|
- |
| CLAUSE 7.3.5.3(Durability of extension elements) |
- |
800 |
|
- |
| CLAUSE 7.3.5.4(Slam shut/open test of extension element) |
- |
800 |
|
- |
| CLAUSE 7.3.5.5(Displacement of extension element bottoms) |
- |
800 |
|
- |
| CLAUSE 7.3.5.6(Interlock test) |
- |
800 |
|
- |
| CLAUSE 7.3.6(Locking and Latching Mechanism Tests) |
- |
0 |
|
CLAUSE WISE RATES GIVEN IN NEXT PARAMETERS |
| CLAUSE 7.3.6.2(Strength test for locking and latching mechanisms for extension elements) |
- |
800 |
|
- |
| CLAUSE 7.3.6.3(Locking and latching mechanisms for doors, flaps and roll-fronts) |
- |
800 |
|
- |
| CLAUSE 7.3.6.4(Durability test of locking and latching mechanisms) |
- |
800 |
|
- |
| CLAUSE 7.3.7(Pull Force Test) |
- |
800 |
|
- |
| CLAUSE 7.3.7(Pull Force Test) |
- |
0 |
|
PARAMETER REPEATED |
| CLAUSE 7.3.8(Top Load Ease Cycle Test) |
- |
800 |
|
- |
| CLAUSE 7.3.9(Durability Test for Units with Seating Surfaces – Cyclic Impact) |
- |
800 |
|
- |
| CLAUSE 7.3.10("Drop Test – Dynamic – for Units with
Seat Surfaces") |
- |
800 |
|
- |
| CLAUSE 7.4.1.3(Sustained load test (overload)) |
- |
800 |
|
- |
| CLAUSE 7.4.1.4(Dislodgement test) |
- |
800 |
|
- |
| CLAUSE 7.5(Stability Tests) |
- |
0 |
|
CLAUSE WISE RATES GIVEN IN NEXT PARAMETERS |
| CLAUSE 7.5.2.1("Units that can be adjusted to a Height of
1 000 mm or less") |
- |
800 |
|
- |
| CLAUSE 7.5.2.2("Units that can be adjusted to a height of
more than 1 000 mm") |
- |
800 |
|
- |
| CLAUSE 7.5.3(Opening Doors, Extension Elements and Flaps, All Storage Units Unloaded) |
- |
800 |
|
- |
| CLAUSE 7.5.6(Vertical Force Stability Test for Storage Units) |
- |
800 |
|
- |
| CLAUSE 7.5.7(Stability Test for Pedestals/Storage Units with Seat Surfaces) |
- |
800 |
|
- |
| CLAUSE 7.5.8("Dynamic Stability Test for Units with
Castors") |
- |
800 |
|
- |
| CLAUSE 7.5.9(Strength Test for Wall Attachments) |
- |
800 |
|
- |
| Cl-7.1(General) |
- |
800 |
|
- |
| Cl-7.2.1(Shelves) |
- |
0 |
|
parameter repeated |
| Cl-7.2.2(Tops and Bottoms) |
- |
0 |
|
CLAUSE WISE RATES GIVEN IN NEXT PARAMETERS |
| Cl-7.2.3(Strength of Clothes Rails and their Supports) |
- |
0 |
|
CLAUSE WISE RATES GIVEN IN NEXT PARAMETERS |
| Cl-7.2.4(Strength of the Structure) |
- |
0 |
|
CLAUSE WISE RATES GIVEN IN NEXT PARAMETERS |
| Cl-7.3.1(Pivoted Doors) |
- |
0 |
|
CLAUSE WISE RATES GIVEN IN NEXT PARAMETERS |
| Cl-7.3.2(Sliding Doors and Horizontal Roll-fronts) |
- |
0 |
|
CLAUSE WISE RATES GIVEN IN NEXT PARAMETERS |
| Cl-7.3.3(Flaps) |
- |
0 |
|
CLAUSE WISE RATES GIVEN IN NEXT PARAMETERS |
| Cl-7.3.4(Vertical Roll-Fronts) |
- |
0 |
|
CLAUSE WISE RATES GIVEN IN NEXT PARAMETERS |
| Cl-7.3.5(Extension Elements) |
- |
0 |
|
CLAUSE WISE RATES GIVEN IN NEXT PARA |
| Cl-7.3.6(Locking and Latching Mechanism Test) |
- |
0 |
|
CLAUSE WISE RATES GIVEN IN NEXT PARAMETERS |
| Cl-7.3.7(Pull Force Test) |
- |
0 |
|
PARAMETER REPEATED |
| Cl-7.3.8(Top Load Ease Cycle Test) |
- |
800 |
|
- |
| Cl-7.3.9(Durability Test for Units with Seating Surfaces – Cyclic Impact) |
- |
800 |
|
- |
| Cl-7.3.10(Drop Test – Dynamic – for Units with Seat Surfaces) |
- |
800 |
|
- |
| Cl-7.4.1(Units Not Supported by the Floor) |
- |
0 |
|
CLAUSE WISE RATES GIVEN IN NEXT PARAMETERS |
| Cl-7.4.2(Units Supported by the Floor) |
- |
800 |
|
- |
| Cl-7.5.1(General) |
- |
800 |
|
- |
| Cl-7.5.2(Doors, Extension Elements and Flaps Closed, All Storage Units Unloaded) |
- |
800 |
|
- |
| Cl-7.5.3(Opening Doors, Extension Elements and Flaps, All Storage Units Unloaded) |
- |
800 |
|
- |
| Cl-7.5.4(Doors, Extension Elements and Flaps Opened and Unlocked) |
- |
800 |
|
- |
| Cl-7.5.5(Doors, Extension Elements and Flaps Closed and Locked, All Storage Units Loaded) |
- |
800 |
|
- |
| Cl-7.5.6(Vertical Force Stability Test for Storage Units) |
- |
800 |
|
- |
| Cl-7.5.7(Stability Test for Pedestals/Storage Units with Seat Surfaces) |
- |
800 |
|
- |
| Cl-7.5.8(Dynamic Stability Test for Units with Castors) |
- |
800 |
|
- |
| Cl-7.5.9(Strength Test for Wall Attachments) |
- |
800 |
|
- |
| Cl-9(Marking) |
- |
300 |
|
- |
| CLAUSE 5(DIMENSIONS) |
- |
0 |
|
PARAMETER REPEATED |
| CLAUSE 6(SURFACE PERFORMANCE) |
- |
0 |
|
PARAMETER REPEATED |
| CLAUSE 6.2(Fabric and Leather (Synthetic and Natural) Performance) |
- |
0 |
|
PARAMETER REPEATED |
| CLAUSE 7.1(SAFETY TESTS (General)) |
- |
0 |
|
PARAMETER REPEATED |
| CLAUSE 7.2(Test for Non-Movable Parts) |
- |
0 |
|
PARAMETER REPEATED |
| Cl-6.1 (a)(Resistance to mechanical damage) |
- |
0 |
|
PARAMETER REPEATED |
| Cl-6.1 (b)(Pencil hardness) |
- |
0 |
|
PARAMETER REPEATED |
| Cl-6.1 (c)(Resistance to wet heat) |
- |
0 |
|
PARAMETER REPEATED |
| Cl-6.1 (d)Cl-6.1 (d)(Resistance to dry heat) |
- |
0 |
|
PARAMETER REPEATED |
| Cl-6.1 (e)(Resistance to marking by cold liquids) |
- |
0 |
|
PARAMETER REPEATED |
| Cl-6.1 (f)(Resistance to marking by cold oils and fats
Resistance to marking by cold oils and fats) |
- |
0 |
|
PARAMETER REPEATED |
| Cl-6.1 (g)(Adhesive performance) |
- |
0 |
|
PARAMETER REPEATED |
| Cl-6.2 (a) 1(Breaking load) |
- |
0 |
|
PARAMETER REPEATED |
| Cl-6.2 (a) 2(Elongation at break) |
- |
0 |
|
PARAMETER REPEATED |
| Cl-6.2 (a) 3(Tear strength) |
- |
0 |
|
PARAMETER REPEATED |
| Cl-6.2 (a) 4(Colour fastness to light) |
- |
0 |
|
PARAMETER REPEATED |
| Cl-6.2 (a) 5(Colour fastness to rubbing) |
- |
0 |
|
PARAMETER REPEATED |
| Cl-6.2 (a) 6(Colour fastness to perspiration) |
- |
0 |
|
PARAMETER REPEATED |
| Cl-6.2 (a) 7(Colour fastness to water) |
- |
0 |
|
PARAMETER REPEATED |
| Cl-6.2 (a) 8(Pilling resistance) |
- |
0 |
|
PARAMETER REPEATED |
| Cl-6.2 (a) 9(Coating adhesion strength) |
- |
0 |
|
PARAMETER REPEATED |
| Cl-6.2 (a) 10(Seam slippage) |
- |
0 |
|
PARAMETER REPEATED |
| Cl-6.2 (a) 11(Resistance to damage by flexing) |
- |
0 |
|
PARAMETER REPEATED |
| Cl-6.2 (a) 12(Abrasion resistance) |
- |
0 |
|
PARAMETER REPEATED |
| Cl-6.2 (a) 13(Bursting strength) |
- |
0 |
|
PARAMETER REPEATED |
| Cl-6.2 (a) 14(Resistance to cold) |
- |
0 |
|
PARAMETER REPEATED |
| Cl-6.2 (b) 1(Tear strength) |
- |
0 |
|
PARAMETER REPEATED |
| Cl-6.2 (b) 2(Flexing endurance) |
- |
0 |
|
PARAMETER REPEATED |
| Cl-6.2 (b) 3(Finish adhesion) |
- |
0 |
|
PARAMETER REPEATED |
| Cl-6.2 (b) 4(Colour fastness to artificial light) |
- |
0 |
|
PARAMETER REPEATED |
| Cl-6.2 (b) 5(Colour fastness to rubbing) |
- |
0 |
|
PARAMETER REPEATED |
| Cl-6.2 (b) 6(Colour fastness to water spotting) |
- |
0 |
|
PARAMETER REPEATED |
| Cl-6.2 (b) 7(Water vapour permeability) |
- |
0 |
|
PARAMETER REPEATED |
| Cl-6.2 (b) 8(Colour fastness to water) |
- |
0 |
|
PARAMETER REPEATED |
| CLAUSE 7.2.1(Shelves) |
- |
0 |
|
PARAMETER REPEATED |
| CLAUSE 7.2.1.2(Deflection of shelves) |
- |
0 |
|
PARAMETER REPEATED |
| CLAUSE 7.2.2.1(Sustained load test for tops and bottoms) |
- |
0 |
|
PARAMETER REPEATED |
| CLAUSE 7.2.2.2(Static load test for tops and bottoms) |
- |
0 |
|
PARAMETER REPEATED |
| CLAUSE 7.2.3.1(Strength of clothes-rail supports) |
- |
0 |
|
PARAMETER REPEATED |
| CLAUSE 7.2.3.2(Dislodgement of clothes rail) |
- |
0 |
|
PARAMETER REPEATED |
| CLAUSE 7.2.4.2(Drop test) |
- |
0 |
|
PARAMETER REPEATED |
| CLAUSE 7.2.4.3(Tests for units with castors or wheels) |
- |
0 |
|
PARAMETER REPEATED |
| CLAUSE 7.3.1(Pivoted Doors) |
- |
0 |
|
PARAMETER REPEATED |
| CLAUSE 7.3.1.2.1(Vertical load on pivoted door) |
- |
0 |
|
PARAMETER REPEATED |
| CLAUSE 7.3.1.2.2(Horizontal load on pivoted door) |
- |
0 |
|
PARAMETER REPEATED |
| CLAUSE 7.3.1.3(Slam-shut test of pivoted doors) |
- |
0 |
|
PARAMETER REPEATED |
| CLAUSE 7.3.1.4(Durability of pivoted doors) |
- |
0 |
|
PARAMETER REPEATED |
| CLAUSE 7.3.2(Sliding Doors and Horizontal Roll-fronts) |
- |
0 |
|
PARAMETER REPEATED |
| CLAUSE 7.3.2.2(Slam shut/open test of sliding doors and horizontal roll-fronts) |
- |
0 |
|
PARAMETER REPEATED |
| CLAUSE 7.3.2.3(Durability of sliding doors and horizontal roll-fronts) |
- |
0 |
|
PARAMETER REPEATED |
| CLAUSE 7.3.3(Flaps) |
- |
0 |
|
PARAMETER REPEATED |
| CLAUSE 7.3.3.1(Strength of bottom-hinged flaps) |
- |
0 |
|
PARAMETER REPEATED |
| CLAUSE 7.3.3.2(Durability of flaps) |
- |
0 |
|
PARAMETER REPEATED |
| CLAUSE 7.3.3.3(Drop test for top-hinged flaps) |
- |
0 |
|
PARAMETER REPEATED |
| CLAUSE 7.3.4(Vertical Roll-Fronts) |
- |
0 |
|
PARAMETER REPEATED |
| CLAUSE 7.3.4.1(Slam shut/open test of vertical roll-fronts) |
- |
0 |
|
PARAMETER REPEATED |
| CLAUSE 7.3.4.2(Durability of vertical roll-fronts) |
- |
0 |
|
PARAMETER REPEATED |
| CLAUSE 7.3.5(Extension Element) |
- |
0 |
|
PARAMETER REPEATED |
| CLAUSE 7.3.5.2(Strength of extension elements) |
- |
0 |
|
PARAMETER REPEATED |
| CLAUSE 7.3.5.3(Durability of extension elements) |
- |
0 |
|
PARAMETER REPEATED |
| CLAUSE 7.3.5.4(Slam shut/open test of extension element) |
- |
0 |
|
PARAMETER REPEATED |
| CLAUSE 7.3.5.5(Displacement of extension element bottoms) |
- |
0 |
|
PARAMETER REPEATED |
| CLAUSE 7.3.5.6(Interlock test) |
- |
0 |
|
PARAMETER REPEATED |
| CLAUSE 7.3.6(Locking and Latching Mechanism Tests) |
- |
0 |
|
PARAMETER REPEATED |
| CLAUSE 7.3.6.2(Strength test for locking and latching mechanisms for extension elements) |
- |
0 |
|
PARAMETER REPEATED |
| CLAUSE 7.3.6.3(Locking and latching mechanisms for doors, flaps and roll-fronts) |
- |
0 |
|
PARAMETER REPEATED |
| CLAUSE 7.3.6.4(Durability test of locking and latching mechanisms) |
- |
0 |
|
PARAMETER REPEATED |
| CLAUSE 7.3.7(Pull Force Test) |
- |
0 |
|
PARAMETER REPEATED |
| CLAUSE 7.3.7(Pull Force Test) |
- |
0 |
|
PARAMETER REPEATED |
| CLAUSE 7.3.8(Top Load Ease Cycle Test) |
- |
0 |
|
PARAMETER REPEATED |
| CLAUSE 7.3.9(Durability Test for Units with Seating Surfaces – Cyclic Impact) |
- |
0 |
|
PARAMETER REPEATED |
| CLAUSE 7.3.10("Drop Test – Dynamic – for Units with
Seat Surfaces") |
- |
0 |
|
PARAMETER REPEATED |
| CLAUSE 7.4.1.3(Sustained load test (overload)) |
- |
0 |
|
PARAMETER REPEATED |
| CLAUSE 7.4.1.4(Dislodgement test) |
- |
0 |
|
PARAMETER REPEATED |
| CLAUSE 7.5(Stability Tests) |
- |
0 |
|
PARAMETER REPEATED |
| CLAUSE 7.5.2.1("Units that can be adjusted to a Height of
1 000 mm or less") |
- |
0 |
|
PARAMETER REPEATED |
| CLAUSE 7.5.2.2("Units that can be adjusted to a height of
more than 1 000 mm") |
- |
0 |
|
PARAMETER REPEATED |
| CLAUSE 7.5.3(Opening Doors, Extension Elements and Flaps, All Storage Units Unloaded) |
- |
0 |
|
PARAMETER REPEATED |
| CLAUSE 7.5.6(Vertical Force Stability Test for Storage Units) |
- |
0 |
|
PARAMETER REPEATED |
| CLAUSE 7.5.7(Stability Test for Pedestals/Storage Units with Seat Surfaces) |
- |
0 |
|
PARAMETER REPEATED |
| CLAUSE 7.5.8("Dynamic Stability Test for Units with
Castors") |
- |
0 |
|
PARAMETER REPEATED |
| CLAUSE 7.5.9(Strength Test for Wall Attachments) |
- |
0 |
|
PARAMETER REPEATED |
| Cl-7.1(General) |
- |
0 |
|
PARAMETER REPEATED |
| Cl-7.2.1(Shelves) |
- |
0 |
|
PARAMETER REPEATED |
| Cl-7.2.2(Tops and Bottoms) |
- |
0 |
|
PARAMETER REPEATED |
| Cl-7.2.3(Strength of Clothes Rails and their Supports) |
- |
0 |
|
PARAMETER REPEATED |
| Cl-7.2.4(Strength of the Structure) |
- |
0 |
|
PARAMETER REPEATED |
| Cl-7.3.1(Pivoted Doors) |
- |
0 |
|
PARAMETER REPEATED |
| Cl-7.3.2(Sliding Doors and Horizontal Roll-fronts) |
- |
0 |
|
PARAMETER REPEATED |
| Cl-7.3.3(Flaps) |
- |
0 |
|
PARAMETER REPEATED |
| Cl-7.3.4(Vertical Roll-Fronts) |
- |
0 |
|
PARAMETER REPEATED |
| Cl-7.3.5(Extension Elements) |
- |
0 |
|
PARAMETER REPEATED |
| Cl-7.3.6(Locking and Latching Mechanism Test) |
- |
0 |
|
PARAMETER REPEATED |
| Cl-7.3.7(Pull Force Test) |
- |
0 |
|
PARAMETER REPEATED |
| Cl-7.3.8(Top Load Ease Cycle Test) |
- |
0 |
|
PARAMETER REPEATED |
| Cl-7.3.9(Durability Test for Units with Seating Surfaces – Cyclic Impact) |
- |
0 |
|
PARAMETER REPEATED |
| Cl-7.3.10(Drop Test – Dynamic – for Units with Seat Surfaces) |
- |
0 |
|
PARAMETER REPEATED |
| Cl-7.4.1(Units Not Supported by the Floor) |
- |
0 |
|
PARAMETER REPEATED |
| Cl-7.4.2(Units Supported by the Floor) |
- |
0 |
|
PARAMETER REPEATED |
| Cl-7.5.1(General) |
- |
0 |
|
PARAMETER REPEATED |
| Cl-7.5.2(Doors, Extension Elements and Flaps Closed, All Storage Units Unloaded) |
- |
0 |
|
PARAMETER REPEATED |
| Cl-7.5.3(Opening Doors, Extension Elements and Flaps, All Storage Units Unloaded) |
- |
0 |
|
PARAMETER REPEATED |
| Cl-7.5.4(Doors, Extension Elements and Flaps Opened and Unlocked) |
- |
0 |
|
PARAMETER REPEATED |
| Cl-7.5.5(Doors, Extension Elements and Flaps Closed and Locked, All Storage Units Loaded) |
- |
0 |
|
PARAMETER REPEATED |
| Cl-7.5.6(Vertical Force Stability Test for Storage Units) |
- |
0 |
|
PARAMETER REPEATED |
| Cl-7.5.7(Stability Test for Pedestals/Storage Units with Seat Surfaces) |
- |
0 |
|
PARAMETER REPEATED |
| Cl-7.5.8(Dynamic Stability Test for Units with Castors) |
- |
0 |
|
PARAMETER REPEATED |
| Cl-7.5.9(Strength Test for Wall Attachments) |
- |
0 |
|
PARAMETER REPEATED |
| Cl-9(Marking) |
- |
0 |
|
PARAMETER REPEATED |
|
31 Dec, 2026 |
- Included w.e.f. 27.04.2026 |
| 1301 |
National Test House (NER) - NTH, Guwahati
| 5169204
| IS 7098 : Part 1 (1988) |
Specification for crosslinked polyethylene insulated pvc sheathed cables: Part 1 for working voltages up to and including 1100 volts (First Revision) |
- |
35000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 3(CONDUCTOR: MATERIALS) |
- |
0 |
|
- |
| 4(INSULATION : MATERIALS) |
- |
0 |
|
- |
| 5.1(FILLER AND INNER SHEATH) |
- |
0 |
|
- |
| 5.2(FILLER AND INNER SHEATH) |
- |
0 |
|
- |
| 7(OUTER SHEATH) |
- |
0 |
|
- |
| 8.1(CONDUCTOR: CONSTRUCTION) |
- |
0 |
|
- |
| 8.2(PROTECTIVE BARRIER) |
- |
0 |
|
- |
| 8.3(SIZE OF NEUTRAL CONDUCTOR) |
- |
0 |
|
- |
| 9.1(Insulation Applied by extrusicn) |
- |
0 |
|
- |
| 9.2(Thickness of Insulation - Average) |
- |
250 |
|
- |
| 9.3(Thickness of Insulation - Minimum) |
- |
250 |
|
- |
| 9.4(Application of Insulation) |
- |
0 |
|
- |
| 10.1(Core Identification) |
- |
0 |
|
- |
| 10.2(Core Identification- Neutral) |
- |
0 |
|
- |
| 10.3(Core Identification by number ) |
- |
0 |
|
- |
| 10.4(Core Identification by number - Neutral ) |
- |
0 |
|
- |
| 11(LAVING UP OF CORES) |
- |
0 |
|
- |
| 12.1 & 12.2(Inner sheath : Application) |
- |
0 |
|
- |
| 12.3(Thickness of Inner Sheath) |
- |
250 |
|
- |
| 13.1(Armouring: Application) |
- |
0 |
|
- |
| 13.1.2(Armouring: Coverage ) |
- |
0 |
|
- |
| 13.1.3(Armouring: Direction of Lay ) |
- |
0 |
|
- |
| 13.2(Type of armour ) |
- |
0 |
|
- |
| 13.3(Armouring : Dimensions -Wire Diameter) |
- |
250 |
|
- |
| 13.3(Armouring : Dimensions -Formed wire ) |
- |
0 |
|
- |
| 13.4(Armour: Joint) |
- |
0 |
|
- |
| 13.5(Armouring : Resistance Test) |
- |
2000 |
|
- |
| 14.1(Outer Sheath : Application) |
- |
0 |
|
- |
| 14.2(Colour of outer sheath) |
- |
0 |
|
- |
| 14.3(Thickness of outer sheath - AVERAGE) |
- |
250 |
|
- |
| 14.3(Thickness of outer sheath - minimum) |
- |
250 |
|
- |
| 15.1 a) i)(Annealing Test ( For copper wire ) ) |
- |
1000 |
|
- |
| 15.1 a) ii)(Tensile test (for aluminium) - Before stranding ) |
- |
1000 |
|
- |
| 15.1 a) ii)(Tensile test (for aluminium) - After stranding ) |
- |
1000 |
|
- |
| 15.1 a) iii)(Wrapping test (for aluminium)) |
- |
500 |
|
- |
| 15.1 a) iv)(Resistance test - Main conductor) |
- |
1000 |
|
- |
| 15.1 a) iv)(Resistance test - Neutral conductor) |
- |
1000 |
|
- |
| 15.1 d) i) (Phyaical tests for insulation : Tensile Test) |
- |
1500 |
|
- |
| 15.1 d) i) (Phyaical tests for insulation : Elongation) |
- |
0 |
|
- |
| 15.1 d) ii) (Phyaical tests for insulation - Ageing in air Oven : Tensile Variation ) |
- |
2000 |
|
- |
| 15.1 d) ii) (Phyaical tests for insulation- Ageing in air oven : Elongation Variation ) |
- |
0 |
|
- |
| 15.1 d) iii) (Phyaical tests for insulation : Hot set ) |
- |
1000 |
|
- |
| 15.1 d) iii) (Phyaical tests for insulation : Permanent set ) |
- |
0 |
|
- |
| 15.1 d) iv) (Phyaical tests for insulation : Shrinkage ) |
- |
1000 |
|
- |
| 15.1 d) iv) (Phyaical tests for insulation : Shrinkage - Crack observed ) |
- |
0 |
|
- |
| 15.1 d) v) (Insulation: Waterabsorption(gravimetric)) |
- |
2000 |
|
- |
| 15.1 e) i) (Physical tests for outer sheath : Tensile stregth) |
- |
1000 |
|
- |
| 15.1 e) i) (Physical tests for outer sheath : Elongation) |
- |
0 |
|
- |
| 15.1 e) ii) (Physical tests for outer sheath- Ageing in air oven : Tensile stregth ) |
- |
0 |
|
- |
| 15.1 e) ii) (Physical tests for outer sheath -Ageing in air oven : Elongation ) |
- |
1000 |
|
- |
| 15.1 e) ii) (Physical tests for outer sheath- Ageing in air oven : Tensile stregth Variation ) |
- |
0 |
|
- |
| 15.1 e) ii) (Physical tests for outer sheath -Ageing in air oven : Elongation Variation ) |
- |
0 |
|
- |
| 15.1 e) iii) (Sheath: Loss of mass in air oven) |
- |
1000 |
|
- |
| 15.1 e) iv) (Phyaical tests for Sheath : Shrinkage ) |
- |
500 |
|
- |
| 15.1 e) iv) (Phyaical tests for Sheath : Shrinkage - Crack observed ) |
- |
0 |
|
- |
| 15.1 e) v) (Sheath : Hot deformation) |
- |
500 |
|
- |
| 15.1 e) vi) (Sheath : Heat shock test) |
- |
500 |
|
- |
| 15.1 e) vii) (Sheath : Thermalstability) |
- |
1000 |
|
- |
| 15.1 f)(INSULATION RESISTANCE TEST : Volume resistivity ) |
- |
2000 |
|
- |
| 16.2(HIGH VOLTAGE TEST ) |
- |
2000 |
|
- |
| 16.3(FLAMMABILITY TEST : Period of Burning ) |
- |
500 |
|
- |
| 16.3(FLAMMABILITY TEST : Unaffected length ) |
- |
0 |
|
- |
| 16.9(Oxygen Index Test) |
- |
5000 |
|
- |
| 16.13(Test for Halogen Acid Gas Evolution) |
- |
5000 |
|
- |
| 16.14(Temperature Index) |
- |
50000 |
|
- |
| 17.1(Manufacturer'. identification) |
- |
0 |
|
- |
| 17.2(cable Indentification ) |
- |
0 |
|
- |
| 17.3(cable Code ) |
- |
0 |
|
- |
| 15.4 (a)(Cold bend) |
- |
1000 |
|
- |
| 15.4 (b)(Cold impact) |
- |
1000 |
|
- |
| Table 1(Ageing in air oven - Elongation on Insulation) |
- |
0 |
|
- |
| Table 1(Ageing in air oven - Tensile strength on Insulation) |
- |
0 |
|
- |
| Table 1(Ageing in air oven - Elongation on Insulation) |
- |
0 |
|
- |
| Table 1(Ageing in air oven - Tensile strength on Insulation) |
- |
0 |
|
- |
| Table 4(Copper purity test) |
- |
1000 |
|
- |
| Table 2(Cold Impact test for Outer sheath) |
- |
0 |
|
- |
| Cl 16(Halogen Acid Gas Test) |
- |
5000 |
|
- |
| Cl.8(Conductor) |
- |
0 |
|
- |
| Cl.15.4(Cold Bend Test (for outer sheath)) |
- |
1000 |
|
- |
| Cl.15.4(Cold Impact Test (For outer sheath)) |
- |
1000 |
|
- |
| Cl.13.5.1 and Table 7(Resistance Test for Armouring (other than mining Cables)) |
- |
0 |
|
- |
| 13.6 a)(ARMOURING: Tensile Strength) |
- |
1500 |
|
- |
| 13.6 b)(ARMOURING: Elongation ) |
- |
0 |
|
- |
| 13.6 c)(ARMOURING: Torsion Test (For round wire ) ) |
- |
0 |
|
- |
| 13.6 d)(ARMOURING: Winding Test(For formed wire)) |
- |
0 |
|
- |
| 13.6 e)(ARMOURING: Uniformity of zinc coating) |
- |
2000 |
|
- |
| 13.6 g)(ARMOURING: Resistivity) |
- |
1500 |
|
- |
| 13.6 f)(ARMOURING: Mass of zinc coating ) |
- |
2000 |
|
- |
| Cl No. 16.15(Smoke density test) |
- |
5000 |
|
- |
| Table 2(Cold bend test for Outer sheath) |
- |
1000 |
|
- |
| 3(CONDUCTOR: MATERIALS) |
- |
0 |
|
- |
| 4(INSULATION : MATERIALS) |
- |
0 |
|
- |
| 5.1(FILLER AND INNER SHEATH) |
- |
0 |
|
- |
| 5.2(FILLER AND INNER SHEATH) |
- |
0 |
|
- |
| 7(OUTER SHEATH) |
- |
0 |
|
- |
| 8.1(CONDUCTOR: CONSTRUCTION) |
- |
0 |
|
- |
| 8.2(PROTECTIVE BARRIER) |
- |
0 |
|
- |
| 8.3(SIZE OF NEUTRAL CONDUCTOR) |
- |
0 |
|
- |
| 9.1(Insulation Applied by extrusicn) |
- |
0 |
|
- |
| 9.2(Thickness of Insulation - Average) |
- |
250 |
|
- |
| 9.3(Thickness of Insulation - Minimum) |
- |
250 |
|
- |
| 9.4(Application of Insulation) |
- |
0 |
|
- |
| 10.1(Core Identification) |
- |
0 |
|
- |
| 10.2(Core Identification- Neutral) |
- |
0 |
|
- |
| 10.3(Core Identification by number ) |
- |
0 |
|
- |
| 10.4(Core Identification by number - Neutral ) |
- |
0 |
|
- |
| 11(LAVING UP OF CORES) |
- |
0 |
|
- |
| 12.1 & 12.2(Inner sheath : Application) |
- |
0 |
|
- |
| 12.3(Thickness of Inner Sheath) |
- |
250 |
|
- |
| 13.1(Armouring: Application) |
- |
0 |
|
- |
| 13.1.2(Armouring: Coverage ) |
- |
0 |
|
- |
| 13.1.3(Armouring: Direction of Lay ) |
- |
0 |
|
- |
| 13.2(Type of armour ) |
- |
0 |
|
- |
| 13.3(Armouring : Dimensions -Wire Diameter) |
- |
0 |
|
- |
| 13.3(Armouring : Dimensions -Formed wire ) |
- |
0 |
|
- |
| 13.4(Armour: Joint) |
- |
0 |
|
- |
| 13.5(Armouring : Resistance Test) |
- |
1500 |
|
- |
| 14.1(Outer Sheath : Application) |
- |
0 |
|
- |
| 14.2(Colour of outer sheath) |
- |
0 |
|
- |
| 14.3(Thickness of outer sheath - AVERAGE) |
- |
250 |
|
- |
| 14.3(Thickness of outer sheath - minimum) |
- |
250 |
|
- |
| 15.1 a) i)(Annealing Test ( For copper wire ) ) |
- |
1000 |
|
- |
| 15.1 a) ii)(Tensile test (for aluminium) - Before stranding ) |
- |
1000 |
|
- |
| 15.1 a) ii)(Tensile test (for aluminium) - After stranding ) |
- |
1000 |
|
- |
| 15.1 a) iii)(Wrapping test (for aluminium)) |
- |
500 |
|
- |
| 15.1 a) iv)(Resistance test - Main conductor) |
- |
1500 |
|
- |
| 15.1 a) iv)(Resistance test - Neutral conductor) |
- |
1500 |
|
- |
| 15.1 d) i) (Phyaical tests for insulation : Tensile Test) |
- |
1500 |
|
- |
| 15.1 d) i) (Phyaical tests for insulation : Elongation) |
- |
0 |
|
- |
| 15.1 d) ii) (Phyaical tests for insulation - Ageing in air Oven : Tensile Variation ) |
- |
0 |
|
- |
| 15.1 d) ii) (Phyaical tests for insulation- Ageing in air oven : Elongation Variation ) |
- |
0 |
|
- |
| 15.1 d) iii) (Phyaical tests for insulation : Hot set ) |
- |
1000 |
|
- |
| 15.1 d) iii) (Phyaical tests for insulation : Permanent set ) |
- |
1000 |
|
- |
| 15.1 d) iv) (Phyaical tests for insulation : Shrinkage ) |
- |
1000 |
|
- |
| 15.1 d) iv) (Phyaical tests for insulation : Shrinkage - Crack observed ) |
- |
0 |
|
- |
| 15.1 d) v) (Insulation: Waterabsorption(gravimetric)) |
- |
2000 |
|
- |
| 15.1 e) i) (Physical tests for outer sheath : Tensile stregth) |
- |
1500 |
|
- |
| 15.1 e) i) (Physical tests for outer sheath : Elongation) |
- |
0 |
|
- |
| 15.1 e) ii) (Physical tests for outer sheath- Ageing in air oven : Tensile stregth ) |
- |
2000 |
|
- |
| 15.1 e) ii) (Physical tests for outer sheath -Ageing in air oven : Elongation ) |
- |
0 |
|
- |
| 15.1 e) ii) (Physical tests for outer sheath- Ageing in air oven : Tensile stregth Variation ) |
- |
0 |
|
- |
| 15.1 e) ii) (Physical tests for outer sheath -Ageing in air oven : Elongation Variation ) |
- |
0 |
|
- |
| 15.1 e) iii) (Sheath: Loss of mass in air oven) |
- |
2000 |
|
- |
| 15.1 e) iv) (Phyaical tests for Sheath : Shrinkage ) |
- |
1000 |
|
- |
| 15.1 e) iv) (Phyaical tests for Sheath : Shrinkage - Crack observed ) |
- |
0 |
|
- |
| 15.1 e) v) (Sheath : Hot deformation) |
- |
500 |
|
- |
| 15.1 e) vi) (Sheath : Heat shock test) |
- |
500 |
|
- |
| 15.1 e) vii) (Sheath : Thermalstability) |
- |
1000 |
|
- |
| 15.1 f)(INSULATION RESISTANCE TEST : Volume resistivity ) |
- |
2000 |
|
- |
| 16.2(HIGH VOLTAGE TEST ) |
- |
2000 |
|
- |
| 16.3(FLAMMABILITY TEST : Period of Burning ) |
- |
250 |
|
- |
| 16.3(FLAMMABILITY TEST : Unaffected length ) |
- |
250 |
|
- |
| 16.9(Oxygen Index Test) |
- |
5000 |
|
- |
| 16.13(Test for Halogen Acid Gas Evolution) |
- |
5000 |
|
- |
| 16.14(Temperature Index) |
- |
5000 |
|
- |
| 17.1(Manufacturer'. identification) |
- |
0 |
|
- |
| 17.2(cable Indentification ) |
- |
0 |
|
- |
| 17.3(cable Code ) |
- |
0 |
|
- |
| 15.4 (a)(Cold bend) |
- |
1000 |
|
- |
| 15.4 (b)(Cold impact) |
- |
1500 |
|
- |
| Table 1(Ageing in air oven - Elongation on Insulation) |
- |
2000 |
|
- |
| Table 1(Ageing in air oven - Tensile strength on Insulation) |
- |
2000 |
|
- |
| Table 1(Ageing in air oven - Elongation on Insulation) |
- |
2000 |
|
- |
| Table 1(Ageing in air oven - Tensile strength on Insulation) |
- |
2000 |
|
- |
| Table 4(Copper purity test) |
- |
1000 |
|
- |
| Table 2(Cold Impact test for Outer sheath) |
- |
1500 |
|
- |
| Cl 16(Halogen Acid Gas Test) |
- |
5000 |
|
- |
| Cl.8(Conductor) |
- |
0 |
|
- |
| Cl.15.4(Cold Bend Test (for outer sheath)) |
- |
1000 |
|
- |
| Cl.15.4(Cold Impact Test (For outer sheath)) |
- |
1500 |
|
- |
| Cl.13.5.1 and Table 7(Resistance Test for Armouring (other than mining Cables)) |
- |
1500 |
|
- |
| 13.6 a)(ARMOURING: Tensile Strength) |
- |
1000 |
|
- |
| 13.6 b)(ARMOURING: Elongation ) |
- |
0 |
|
- |
| 13.6 c)(ARMOURING: Torsion Test (For round wire ) ) |
- |
1000 |
|
- |
| 13.6 d)(ARMOURING: Winding Test(For formed wire)) |
- |
0 |
|
- |
| 13.6 e)(ARMOURING: Uniformity of zinc coating) |
- |
1000 |
|
- |
| 13.6 g)(ARMOURING: Resistivity) |
- |
1500 |
|
- |
| 13.6 f)(ARMOURING: Mass of zinc coating ) |
- |
1000 |
|
- |
| Cl No. 16.15(Smoke density test) |
- |
5000 |
|
- |
| Table 2(Cold bend test for Outer sheath) |
- |
1000 |
|
- |
|
13 Dec, 2027 |
- Included w.e.f 12.02.2026
Exclusion: Cl 16.1 (Flame Retardance Test on Single Cables), 16.11 (Flame Retardance Test on Bunched Cables) |
| 1302 |
CIMEC Infralabs Private Limited
| 8195606
| IS 1341 (2018) |
Steel Butt Hinges - Specification (Sixth Revision) |
Size: 25 to 200 mm, Light, Medium and Heavy |
5500 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 3 Tables 2 to 9(Types) |
- |
100 |
|
- |
| 5.1 Tables 2 to 9 (2)(Size of Hinge) |
- |
100 |
|
- |
| 5.1 Tables 2 to 9 (3)(Length A) |
- |
200 |
|
- |
| 5.1 Tables 2 to 9 (4)(Breadth B) |
- |
200 |
|
- |
| 5.1 Tables 2 to 9 (4)(Breadth B1) |
- |
200 |
|
- |
| 5.1 Tables 2 to 9 (4)(Breadth B2) |
- |
200 |
|
- |
| 5.1 Tables 2 to 9 (5)(Thickness of Flap C) |
- |
200 |
|
- |
| 5.1 Tables 2 to 9 (6)(Diameter of Hinge Pin D) |
- |
200 |
|
- |
| 5.1 Tables 2 to 9 (7)(Number of Knuckles) |
- |
100 |
|
- |
| 5.1 Tables 2 to 9 (8)(Number of Screw Holes) |
- |
100 |
|
- |
| 5.1 Tables 2 to 9 (9)(Holes for Screw No.) |
- |
200 |
|
- |
| 6.1(General) |
- |
100 |
|
- |
| 6.1(General) |
- |
100 |
|
- |
| 6.1(General) |
- |
100 |
|
- |
| 6.2.1(Knuckles) |
- |
150 |
|
- |
| 6.3(Pins) |
- |
150 |
|
- |
| 6.4(Screw Holes) |
- |
150 |
|
- |
| 6.4.2(Position of Holes) |
- |
150 |
|
- |
| 6.4.2(X) |
- |
100 |
|
- |
| 6.4.2(Y) |
- |
100 |
|
- |
| 6.4.2(Z) |
- |
100 |
|
- |
| 6.4.2.1(Position of Holes) |
- |
100 |
|
- |
| 7(Finish) |
- |
100 |
|
Physical Test: INR 3200 |
| TABLE-1 (Clause-4)(TITANIUM) |
- |
150 |
|
- |
| TABLE-1 (Clause-4)(VANADIUM) |
- |
150 |
|
- |
| TABLE-1 (Clause-4)(NIOBIUM) |
- |
150 |
|
- |
| TABLE-1 (Clause-4)(Molybdenum) |
- |
150 |
|
- |
| TABLE-1 (Clause-4)(Chromium) |
- |
150 |
|
- |
| TABLE-1 (Clause-4)(Nickel) |
- |
150 |
|
- |
| TABLE-1 (Clause-4)( ALUMINIUM) |
- |
150 |
|
- |
| TABLE-1 (Clause-4)(SILICON) |
- |
150 |
|
- |
| TABLE-1 (Clause-4)(NITROGEN) |
- |
150 |
|
- |
| TABLE-1 (Clause-4)(MANGANESE) |
- |
150 |
|
- |
| TABLE-1 (Clause-4)(PHOSPHURS) |
- |
150 |
|
- |
| TABLE-1 (Clause-4)(SULPHUR) |
- |
150 |
|
- |
| TABLE-1 (Clause-4)( CARBON) |
- |
150 |
|
- |
| Clause 4 Table 1(Manganese ( Pin)) |
- |
150 |
|
- |
| Clause 4 Table 1(Phosphorus ( Pin)) |
- |
150 |
|
- |
| Clause 4 Table 1(Sulphur ( Pin)) |
- |
150 |
|
- |
| Clause 4 Table 1(Carbon ( Pin)) |
- |
150 |
|
- |
| Clause 4 Table 1(Nitrogen ( Flap)) |
- |
150 |
|
- |
| Clause 4 Table 1(Manganese ( Flap)) |
- |
150 |
|
- |
| Clause 4 Table 1(Phosphorus ( Flap)) |
- |
150 |
|
- |
| Clause 4 Table 1(Sulphur ( Flap)) |
- |
150 |
|
- |
| Clause 4 Table 1(Carbon ( Flap)) |
- |
150 |
|
- |
| 8(Marking) |
- |
150 |
|
- |
| Cl 4 & Table 1(Sulphur- IS 228(Part 9)) |
- |
250 |
|
- |
| Cl 4 & Table 1(Carbon- IS 228(Part 1)) |
- |
250 |
|
- |
| Cl 4 & Table 1(Phosphorous- IS 228(Part 3)) |
- |
250 |
|
- |
| Cl 4 & Table 1(Manganese- IS 228(Part 2)) |
- |
250 |
|
- |
| Cl 4 & Table 1(Silicon- IS 228(Part 2)) |
- |
250 |
|
- |
| Cl 4 & Table 1(Nitrogen -IS 228(Part 19)) |
- |
250 |
|
Chemical Tests: INR 2500 |
|
14 Jan, 2029 |
- included w.e.f 09.04.2026 |
| 1303 |
MORBI TEST HOUSE LLP
| 7195306
| IS 2202 : Part 2 (2022) |
WOODEN FLUSH DOOR SHUTTERS SOLID CORE TYPE SPECIFICATION PART 2 PARTICLE BOARD HIGH DENSITY FIBRE BOARD MEDIUM DENSITY FIBRE BOARD AND HARDBOARD FACE PANELS Fourth Revision |
All Grade / Type / Size / Designation |
22500 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Clause No - 6.1(Timber) |
- |
100 |
|
- |
| Clause No -6.2(Alternative Materials (LVL) |
- |
0 |
|
- |
| Clause No -6.2(Alternative Materials veneer laminated lumber (VLL)) |
- |
0 |
|
- |
| Clause No -6.2(Alternative Materials medium density fibre board (MDF)) |
- |
0 |
|
- |
| Clause No -6.2(Alternative Materials -plywood) |
- |
4000 |
|
- |
| Clause No -6.2(BWP grade flush door shutter) |
- |
1000 |
|
- |
| Clause No -6.3.1("Face Panels:
Particle Board
MDF/ HDF
Fibre Hardboard") |
- |
0 |
|
- |
| Clause No -6.4(Adhesive) |
- |
4000 |
|
- |
| Clause No -7.1(Construction) |
- |
1000 |
|
- |
| Clause No - 7.3(" MDF board or
HDF board ") |
- |
0 |
|
- |
| Clause No -9.2("Workmanship and
finish") |
- |
200 |
|
- |
| Clause No -10.1(tests for flush door shutters) |
- |
19000 |
|
- |
| Clause No -10.2(End Immersion Test) |
- |
1000 |
|
- |
| Clause No -10.3(Glue Adhesion Test) |
- |
1000 |
|
- |
| Clause No -11(SAMPLING AND CRITERIA FOR CONFORMITY) |
- |
0 |
|
- |
| 5(SIZES AND TOLERANCES) |
- |
1300 |
|
- |
| 6.5(The swelling in thickness of the particle board, MDF
and HDF board for core) |
- |
200 |
|
- |
| Cl-6.3.3 (Amendment NO 1)(B D P V, P D P V and M D P V types of flush door) |
- |
0 |
|
- |
| Cl-6.3.2(MDF board and HDF board) |
- |
0 |
|
- |
| Cl-6.3.4(B N P V, P N P V and M N P V,) |
- |
0 |
|
- |
| Cl-7.2(Face Panel) |
- |
0 |
|
- |
| Cl-7.4 (Amendment No 1)(Door Blanks) |
- |
0 |
|
- |
| Cl-8(Fittings) |
- |
100 |
|
- |
|
- |
- Included w.e.f. 22.01.2026
Exclusion: Clause No -12 ("ADDITIONAL REQUIREMENTS FOR ECO MARK") |
| 1304 |
MORBI TEST HOUSE LLP
| 7195306
| IS 2191 : Part 2 (2022) |
WOODEN FLUSH DOOR SHUTTERS (CELLULAR, HOLLOW AND TUBULAR CORE TYPE) - SPECIFICATION PART 2 PARTICLE BOARD, HIGH DENSITY FIBRE BOARD, MEDIUM DENSITY FIBRE BOARD AND FIBRE HARDBOARD FACE PANELS (Fourth Revision) |
All Grade / Type / Size / Designation |
22500 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl-5(Sizes and Tolerances) |
- |
1300 |
|
- |
| Cl-6.1.(Timber) |
- |
100 |
|
- |
| Cl-6.2(Laminated veneer lumber (LVL), veneer laminated lumber (VLL), medium density fibre board (MDF), high density fibre board (HDF)) |
- |
0 |
|
- |
| Cl-6.3.1(Particle board) |
- |
0 |
|
- |
| Cl-6.3.2(MDF board and HDF board) |
- |
0 |
|
- |
| Cl-6.3.5(shutters with fibre hardboard face) |
- |
0 |
|
- |
| Cl-8.1(Locks) |
- |
100 |
|
- |
| Cl-10.1(various test) |
- |
19000 |
|
- |
| Cl-10.2(End Immersion Test) |
- |
1000 |
|
- |
| Cl-10.3(Glue Adhesion Test) |
- |
1000 |
|
- |
| Cl-13(Marking) |
- |
100 |
|
- |
|
- |
- Included w.e.f. 22.01.2026 |
| 1305 |
Arihant Analytical Laboratory Pvt. Ltd., Sonipat
| 9167906
| IS 8042 (2015) |
White portland cement - Specification (Third Revision) |
All Type |
8200.00 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 5 - Table - 1 i(Ratio of percentage of lime to percentages of silica, alumina and iron oxide - Cl 4 of IS 4032:1985) |
- |
8200.00 |
|
- |
| 5 - Table - 1 ii(Iron oxide - Cl 4.5 of IS 4032:1985) |
- |
8200.00 |
|
- |
| 5 - Table - 1 iii(Insoluble residue - Cl 4.10 of IS 4032:1985) |
- |
8200.00 |
|
- |
| 5 - Table - 1 iv(Magnesia - Cl 4.8 of IS 4032:1985) |
- |
8200.00 |
|
- |
| 5 - Table - 1 v(Total Sulphur Content calculated as Sulphuric Anhydride (SO3) - Cl 4.9 of IS 4032:1985) |
- |
8200.00 |
|
- |
| 5 - Table - 1 vi(Loss on ignition - Cl 4.2 of IS 4032:1985) |
- |
8200.00 |
|
- |
| 5 - Table - 1 vii(Chloride content - Cl 4.13 of IS 4032:1985) |
- |
8200.00 |
|
- |
| 6 -Table 2- i(Fineness 4031 Part 2) |
- |
8200.00 |
|
- |
| 6 -Table 2- ii- a(Expansion by Le Chatelier- 4031 Part 3) |
- |
8200.00 |
|
- |
| 6 -Table 2- ii- a(Expansion after aeration - 4031 Part 3) |
- |
8200.00 |
|
- |
| 6 -Table 2- ii- b(Expansion by Autoclave- 4031 Part 3) |
- |
8200.00 |
|
- |
| 6-Table 2- ii- b(Expansion after aeration- 4031 Part 3) |
- |
8200.00 |
|
- |
| 6 -Table 2- iii- a(Setting Time Initial- 4031 Part 5) |
- |
8200.00 |
|
- |
| 6 -Table 2-iii- b(Setting Time Final- 4031 Part 5) |
- |
8200.00 |
|
- |
| 6 -Table 2- iv- a(Compressive Strength At 72 hrs ± 1 hr - IS 4031 Part 6) |
- |
8200.00 |
|
- |
| 6 -Table 2- iv- b(Compressive Strength At 168 hrs ± 2 hr - IS 4031 Part 6) |
- |
8200.00 |
|
- |
| 6 -Table 2- iv- c(Compressive Strength At 672 hrs ± 4 hr - IS 4031 Part 6) |
- |
8200.00 |
|
- |
| 6 -Table 2- v(Transverse Strength - IS 4031 Part 8 (Optional)) |
- |
8200.00 |
|
- |
| 6 -Table 2- vi(Degree of whiteness-Annex B) |
- |
8200.00 |
|
- |
| 5 - Table - 1 i(Ratio of percentage of lime to percentages of silica, alumina and iron oxide - Cl 4 of IS 4032:1985) |
- |
8200.00 |
|
- |
| 5 - Table - 1 ii(Iron oxide - Cl 4.5 of IS 4032:1985) |
- |
8200.00 |
|
- |
| 5 - Table - 1 iii(Insoluble residue - Cl 4.10 of IS 4032:1985) |
- |
8200.00 |
|
- |
| 5 - Table - 1 iv(Magnesia - Cl 4.8 of IS 4032:1985) |
- |
8200.00 |
|
- |
| 5 - Table - 1 v(Total Sulphur Content calculated as Sulphuric Anhydride (SO3) - Cl 4.9 of IS 4032:1985) |
- |
8200.00 |
|
- |
| 5 - Table - 1 vi(Loss on ignition - Cl 4.2 of IS 4032:1985) |
- |
8200.00 |
|
- |
| 5 - Table - 1 vii(Chloride content - Cl 4.13 of IS 4032:1985) |
- |
8200.00 |
|
- |
| 6 -Table 2- i(Fineness 4031 Part 2) |
- |
8200.00 |
|
- |
| 6 -Table 2- ii- a(Expansion by Le Chatelier- 4031 Part 3) |
- |
8200.00 |
|
- |
| 6 -Table 2- ii- a(Expansion after aeration - 4031 Part 3) |
- |
8200.00 |
|
- |
| 6 -Table 2- ii- b(Expansion by Autoclave- 4031 Part 3) |
- |
8200.00 |
|
- |
| 6-Table 2- ii- b(Expansion after aeration- 4031 Part 3) |
- |
8200.00 |
|
- |
| 6 -Table 2- iii- a(Setting Time Initial- 4031 Part 5) |
- |
8200.00 |
|
- |
| 6 -Table 2-iii- b(Setting Time Final- 4031 Part 5) |
- |
8200.00 |
|
- |
| 6 -Table 2- iv- a(Compressive Strength At 72 hrs ± 1 hr - IS 4031 Part 6) |
- |
8200.00 |
|
- |
| 6 -Table 2- iv- b(Compressive Strength At 168 hrs ± 2 hr - IS 4031 Part 6) |
- |
8200.00 |
|
- |
| 6 -Table 2- iv- c(Compressive Strength At 672 hrs ± 4 hr - IS 4031 Part 6) |
- |
8200.00 |
|
- |
| 6 -Table 2- v(Transverse Strength - IS 4031 Part 8 (Optional)) |
- |
8200.00 |
|
- |
| 6 -Table 2- vi(Degree of whiteness-Annex B) |
- |
8200.00 |
|
- |
| 6, table-2, ii(Whiteness) |
- |
8200.00 |
|
- |
| Clause 6
Table 2, SI No. (v)
(Compressive strength of Transverse Specimen, 672 ± 4 h) |
- |
8200.00 |
|
- |
| Clause 6
Table 2, SI No. (v)
(Compressive strength of Transverse Specimen, 168 ± 2 h) |
- |
8200.00 |
|
- |
| Clause 6
Table 2, SI No. (v)
(Compressive strength of Transverse Specimen, 72 ± 1 h) |
- |
8200.00 |
|
- |
| Clause 6
Table 2, SI No. (v)
(Transverse Strength, 672 ± 4 h) |
- |
8200.00 |
|
- |
| Clause 6
Table 2, SI No. (v)
(Transverse Strength, 168 ± 2 h) |
- |
8200.00 |
|
- |
| Clause 6
Table 2, SI No. (v)
(Transverse Strength, 72 ± 1 h) |
- |
8200.00 |
|
- |
|
02 Jun, 2027 |
- Included w.e.f. 02.03.2026 |
| 1306 |
MORBI TEST HOUSE LLP
| 7195306
| IS 2191 : Part 1 (2022) |
WOODEN FLUSH DOOR SHUTTERS CELLULAR TUBULAR AND HOLLOW CORE TYPE SPECIFICATION PART 1 PLYWOOD FACE PANELS Fifth Revision |
All Grade / Type / Size / Designation |
22500 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl-5(Sizes) |
- |
100 |
|
- |
| Cl-6.1.1(Species of timber) |
- |
100 |
|
- |
| Cl-6.3(Cross-Bands) |
- |
100 |
|
- |
| Cl-6.4.1(Commercial face veneers) |
- |
100 |
|
- |
| Cl-6.4.2(Decorative face veneers) |
- |
100 |
|
- |
| Cl-6.7(Particle Board) |
- |
1000 |
|
- |
| Cl-6.8(Laminated veneer lumber (LVL), veneer laminated lumber (VLL), Medium Density Fibre (MDF)) |
- |
100 |
|
- |
| Cl-11.1(Dimensions and Squareness Test) |
- |
1500 |
|
- |
| Cl-11.2(General Flatness Test) |
- |
1000 |
|
- |
| Cl-11.3(Local Planeness Test) |
- |
1000 |
|
- |
| Cl-11.4(Impact Indentation Test) |
- |
1500 |
|
- |
| Cl-11.5(Flexure Test) |
- |
1000 |
|
- |
| Cl-11.6(Edge Loading Test) |
- |
2000 |
|
- |
| Cl-11.7(Shock Resistance Test) |
- |
1500 |
|
- |
| Cl-11.8(Buckling Resistance Test) |
- |
2000 |
|
- |
| Cl-11.9(Slamming Test) |
- |
1000 |
|
- |
| Cl-11.10(Misuse Test) |
- |
1000 |
|
- |
| Cl-11.11(Varying Humidity Test) |
- |
2500 |
|
- |
| Cl-11.12(End Immersion Test) |
- |
1500 |
|
- |
| Cl-11.13(Knife Test) |
- |
500 |
|
- |
| Cl-11.14(Glue Adhesion Test) |
- |
1000 |
|
- |
| Cl-11.15(Screw Withdrawal Resistance Test) |
- |
2000 |
|
- |
| Cl-12.2(Sample Size) |
- |
100 |
|
- |
| Cl-14(Marking) |
- |
100 |
|
- |
| Cl-6.1.2(Moisture content of timber) |
- |
100 |
|
- |
| Cl-9(Workmanship and Finish) |
- |
100 |
|
- |
| Cl-6.1.3(Defects) |
- |
200 |
|
- |
| Cl-6.2(Plywood) |
- |
4000 |
|
- |
| Cl-6.5(Cross-bands and face veneers) |
- |
100 |
|
- |
| Cl-6.6(Adhesives) |
- |
4000 |
|
- |
| Cl-7(Construction) |
- |
100 |
|
- |
| Cl-8(Fittings) |
- |
100 |
|
- |
|
- |
- Included w.e.f. 22.01.2026 |
| 1307 |
Samridhi Test House Pvt. Ltd.
| 8184706
| IS 915 (2012) |
Laboratory glassware - One - Mark volumetric flasks (Third Revision) |
All Grade / Type / Size / Designation |
9800 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 8.1(Material) |
- |
0 |
|
- |
| Table 1(Nominal Capacity) |
- |
800 |
|
- |
| Table 1(Internal Neck Diameter) |
- |
300 |
|
- |
| Table 1(Distance of graduation line) |
- |
100 |
|
- |
| Table 1(Overall Height) |
- |
300 |
|
- |
| Table 1(Bulb Diameter) |
- |
300 |
|
- |
| Table 1(Base Diameter) |
- |
300 |
|
- |
| Table 1(Wall Thickness) |
- |
300 |
|
- |
| Table 1(Ground joint k4) |
- |
100 |
|
- |
| Table 1(Ground joint k6) |
- |
100 |
|
- |
| 8.3(Shape) |
- |
100 |
|
- |
| 8.4(Neck) |
- |
300 |
|
- |
| 8.5(Stopper) |
- |
300 |
|
- |
| 8.6(Dimensions) |
- |
1000 |
|
- |
| 9.0(Graduation Line) |
- |
300 |
|
- |
| Table-2(Nominal capacity) |
- |
1000 |
|
- |
| Table-2(Internal neck diameter) |
- |
300 |
|
- |
| Table-2(Distance of graduation line 1)) |
- |
300 |
|
- |
| Table-2(Overall height 2)) |
- |
300 |
|
- |
| Table-2(Bulb diameter) |
- |
300 |
|
- |
| Table-2(Base diameter) |
- |
300 |
|
- |
| Table-2(Wall thickness) |
- |
300 |
|
- |
| Table-2(Ground joint 3) k4) |
- |
100 |
|
- |
| Table-2(Ground joint 3) k6) |
- |
100 |
|
- |
| 12.1(Visibility of graduation line, figures and marking) |
- |
400 |
|
- |
| 12.2(Visibility of graduation line, figures and marking) |
- |
400 |
|
- |
| Clause. 7.0(Accuracy) |
- |
1000 |
|
- |
| Table 1(Nominal Capacity) |
- |
0 |
|
- |
| 9.0(Graduation Line) |
- |
0 |
|
- |
| Table-2(Nominal capacity) |
- |
0 |
|
- |
| Table-2(Internal neck diameter) |
- |
0 |
|
- |
| Table-2(Distance of graduation line 1)) |
- |
0 |
|
- |
| Table-2(Overall height 2)) |
- |
0 |
|
- |
| Table-2(Bulb diameter) |
- |
0 |
|
- |
| Table-2(Base diameter) |
- |
0 |
|
- |
| Table-2(Wall thickness) |
- |
0 |
|
- |
| Table-2(Ground joint 3) k4) |
- |
0 |
|
- |
| Table-2(Ground joint 3) k6) |
- |
0 |
|
- |
| 12.1(Visibility of graduation line, figures and marking) |
- |
0 |
|
- |
| 12.2(Visibility of graduation line, figures and marking) |
- |
0 |
|
- |
| Clause. 7.0(Accuracy) |
- |
0 |
|
- |
| Table 1(Nominal Capacity) |
- |
0 |
|
- |
| 9.0(Graduation Line) |
- |
0 |
|
- |
| Table-2(Nominal capacity) |
- |
0 |
|
- |
| Table-2(Internal neck diameter) |
- |
0 |
|
- |
| Table-2(Distance of graduation line 1)) |
- |
0 |
|
- |
| Table-2(Overall height 2)) |
- |
0 |
|
- |
| Table-2(Bulb diameter) |
- |
0 |
|
- |
| Table-2(Base diameter) |
- |
0 |
|
- |
| Table-2(Wall thickness) |
- |
0 |
|
- |
| Table-2(Ground joint 3) k4) |
- |
0 |
|
- |
| Table-2(Ground joint 3) k6) |
- |
0 |
|
- |
| 12.1(Visibility of graduation line, figures and marking) |
- |
0 |
|
- |
| 12.2(Visibility of graduation line, figures and marking) |
- |
0 |
|
- |
| Clause. 7.0(Accuracy) |
- |
0 |
|
- |
| Table 1(Nominal Capacity) |
- |
0 |
|
- |
| 9.0(Graduation Line) |
- |
0 |
|
- |
| Table-2(Nominal capacity) |
- |
0 |
|
- |
| Table-2(Internal neck diameter) |
- |
0 |
|
- |
| Table-2(Distance of graduation line 1)) |
- |
0 |
|
- |
| Table-2(Overall height 2)) |
- |
0 |
|
- |
| Table-2(Bulb diameter) |
- |
0 |
|
- |
| Table-2(Base diameter) |
- |
0 |
|
- |
| Table-2(Wall thickness) |
- |
0 |
|
- |
| Table-2(Ground joint 3) k4) |
- |
0 |
|
- |
| Table-2(Ground joint 3) k6) |
- |
0 |
|
- |
| 12.1(Visibility of graduation line, figures and marking) |
- |
0 |
|
- |
| 12.2(Visibility of graduation line, figures and marking) |
- |
0 |
|
- |
| Clause. 7.0(Accuracy) |
- |
0 |
|
- |
|
- |
- Included w.e.f. 25.03.2026
Exclusion: 8.1 (Material) |
| 1308 |
IDMA LABORATORIES LIMITED, PANCHKULA
| 9123236
| IS 14709 (2025) |
n-Butyl Acrylate - Specification (First Revision) |
- |
10000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl-3.1, Table-1 (i)(Assay, percent by mass, Min) |
- |
2500 |
|
- |
| Cl-3.1, Table-1 (ii)(Acidity (as acrylic acid), percent by mass, Max) |
- |
1000 |
|
- |
| Cl-3.1, Table-1 (iii)(Colour, Pt-Co scale, Max) |
- |
2000 |
|
- |
| Cl-3.1, Table-1 (iv)(Water content, percent by mass, Max) |
- |
2000 |
|
- |
| Cl-3.1, Table-1 (v)(Inhibitors (as monomethyl etherhydroquinone), ppm, Max) |
- |
2500 |
|
- |
| Cl-3.1, Table-1 (i)(Assay, percent by mass, Min) |
- |
0 |
|
- |
| Cl-4.2(Marking) |
- |
0 |
|
- |
|
31 Dec, 2026 |
- Included w.e.f. 24.02.2026 |
| 1309 |
IDMA LABORATORIES LIMITED, PANCHKULA
| 9123236
| IS 14708 (2025) |
Ethyl Acrylate - Specification (First Revision) |
- |
11000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 3.1 Table 1 (i)(Assay (IS 14708 : 2025)) |
- |
2500 |
|
- |
| 3.1 Table 1 (ii)(Acidity (as Acrylic Acid) (IS 14708 : 2025)) |
- |
1500 |
|
- |
| 3.1 Table 1 (iii)(Colour, Pt - Co scale (IS 8768 / IS 1448 (Part 178)) |
- |
2000 |
|
- |
| 3.1 Table 1 (iv)(Water (IS 2362 / IS 1448 (Part 182)) |
- |
2000 |
|
- |
| 3.1 Table 1 (v)(Inhibitors (as monomethyl Ether Hydroquinone) (IS 14708 : 2025)) |
- |
3000 |
|
- |
|
31 Dec, 2026 |
- included w.e.f 17.03.2026 |
| 1310 |
JBS TESTING SOLUTIONS (Unit-2) (24), Jalandhar
| 9172306
| IS 996 (2025) |
SINGLE PHASE ac INDUCTION MOTORS FOR GENERAL PURPOSE (Fouth Revision) |
- |
17250 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl-7(Dimensions) |
- |
450 |
|
- |
| Cl-9.1(Mounting) |
- |
100 |
|
- |
| Cl-9.2(Terminal Box) |
- |
100 |
|
- |
| Cl-9.3(Mounting Constructions) |
- |
100 |
|
- |
| Cl-9.3(Mounting Constructions) |
- |
100 |
|
- |
| Cl-9.4(Constructional Features) |
- |
100 |
|
- |
| Cl-9.5(Earthing) |
- |
200 |
|
- |
| Cl-10.1(Enclosures) |
- |
200 |
|
- |
| Cl-12.1(Torques) |
- |
750 |
|
- |
| Cl-12.1.2(Momentary overload test) |
- |
799.99 |
|
- |
| Cl-12.2(Temperature Rise) |
- |
1750 |
|
- |
| Cl-12.3(Short Time Rating) |
- |
500 |
|
- |
| Cl-12.4(Method of Testing) |
- |
100 |
|
- |
| Cl-12.5(Performance Values) |
- |
500 |
|
- |
| Cl-12.6(Limits of Vibration Severity) |
- |
450 |
|
- |
| Cl-12.7(Insulation Resistance) |
- |
1000 |
|
- |
| Cl-13.1(High Voltage Values) |
- |
1000 |
|
- |
| Cl-13.2(Moisture Proofness) |
- |
1000 |
|
- |
| Cl-13.3(Leakage Current) |
- |
1000 |
|
- |
| Cl-14(Winding Resistance Measurement) |
- |
1049.99 |
|
- |
| Cl-15(REDUCED VOLTAGE RUNNING UP TEST AT NO LOAD) |
- |
800 |
|
- |
| Cl-16(NOISE LEVEL) |
- |
500 |
|
- |
| Cl-17(OVER SPEED TEST) |
- |
500 |
|
- |
| Cl-18(TERMINAL MARKING) |
- |
500 |
|
- |
| Cl-12.1.1(Test for torues at rated voltage and frequency) |
- |
500 |
|
- |
| Cl-12.1.1(Pull up Torque at rated voltage and frequency) |
- |
500 |
|
- |
| Cl-12.1.1(Test for breakaway starting current at rated voltage and frequency) |
- |
500 |
|
- |
| Cl-12.1.2(Breakaway (starting) torque at rated voltage and frequency) |
- |
500 |
|
- |
| Cl-12.5.1(Test for full-load performance at rated voltage and frequency) |
- |
1000 |
|
- |
| Cl-21.5(Acceptance Tests) |
- |
1000 |
|
- |
|
22 May, 2026 |
- included w.e.f 16.03.2026 |
| 1311 |
AANKAN CALIBRATION AND TESTING CENTRE LLP, DANTLI
| 7184406
| IS 7834 : Part 3 (1987) |
injection moulded PVC socket fittings with solvent cement joints for water supplies: Part 3 Specific requirements for 90 degree elbows |
- |
8000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| cl 2.2.2(Dimensions) |
- |
0 |
|
Complete Testing Charges Rs 8000/-- |
| Cl. 2.1 (Ref. Cl. 6.3 of IS 7834 (part 1) : 1987(Effect on water - Lead (first extraction) - Appendix C ) |
- |
0 |
|
Complete Testing Charges Rs 8000/- |
| Cl. 2.1 (Ref. Cl. 6.3 of IS 7834 (part 1) : 1987(Effect on water - Lead (third extraction) - Appendix C) |
- |
0 |
|
Complete Testing Charges Rs 8000/- |
| Cl. 2.1 (Ref. Cl. 6.3 of IS 7834 (part 1) : 1987(Effect on water - Dialkyl tin C4 and higher homologues measured as tin (third extraction) - Appendix C) |
- |
0 |
|
Complete Testing Charges Rs 8000/- |
| Cl. 2.1 (Ref. Cl. 6.3 of IS 7834 (part 1) : 1987(Effect on water - Other toxic substances (third extraction) - Appendix C) |
- |
0 |
|
Complete Testing Charges Rs 8000/- |
| 6.1.1(VCM Content Test) |
- |
0 |
|
Complete Testing Charges Rs 8000/- |
| 2.2.2 table 1(Laying length) |
- |
0 |
|
Complete Testing Charges Rs 8000/- |
| cl 2.2.2(Dimensions) |
- |
0 |
|
Complete Testing Charges Rs 8000/-- |
| Cl. 2.1 (Ref. Cl. 6.3 of IS 7834 (part 1) : 1987(Effect on water - Lead (first extraction) - Appendix C ) |
- |
0 |
|
Complete Testing Charges Rs 8000/- |
| Cl. 2.1 (Ref. Cl. 6.3 of IS 7834 (part 1) : 1987(Effect on water - Lead (third extraction) - Appendix C) |
- |
0 |
|
Complete Testing Charges Rs 8000/- |
| Cl. 2.1 (Ref. Cl. 6.3 of IS 7834 (part 1) : 1987(Effect on water - Dialkyl tin C4 and higher homologues measured as tin (third extraction) - Appendix C) |
- |
0 |
|
Complete Testing Charges Rs 8000/- |
| Cl. 2.1 (Ref. Cl. 6.3 of IS 7834 (part 1) : 1987(Effect on water - Other toxic substances (third extraction) - Appendix C) |
- |
0 |
|
Complete Testing Charges Rs 8000/- |
| 6.1.1(VCM Content Test) |
- |
0 |
|
Complete Testing Charges Rs 8000/- |
| 2.2.2 table 1(Laying length) |
- |
0 |
|
Complete Testing Charges Rs 8000/- |
| cl 2.2.2(Dimensions) |
- |
0 |
|
- |
| Cl. 2.1 (Ref. Cl. 6.3 of IS 7834 (part 1) : 1987(Effect on water - Lead (first extraction) - Appendix C ) |
- |
0 |
|
- |
| Cl. 2.1 (Ref. Cl. 6.3 of IS 7834 (part 1) : 1987(Effect on water - Lead (third extraction) - Appendix C) |
- |
0 |
|
- |
| Cl. 2.1 (Ref. Cl. 6.3 of IS 7834 (part 1) : 1987(Effect on water - Dialkyl tin C4 and higher homologues measured as tin (third extraction) - Appendix C) |
- |
0 |
|
- |
| Cl. 2.1 (Ref. Cl. 6.3 of IS 7834 (part 1) : 1987(Effect on water - Other toxic substances (third extraction) - Appendix C) |
- |
0 |
|
- |
| 6.1.1(VCM Content Test) |
- |
0 |
|
- |
| 2.2.2 table 1(Laying length) |
- |
0 |
|
- |
|
- |
- Included w.e.f 17.02.2026 |
| 1312 |
Unique Test House LLP
| 9134536
| IS 5504 (2025) |
Spiral Welded Pipes - Specification (Second Revision) |
ALL SIZES |
11000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 1(SCOPE) |
- |
200 |
|
........ |
| 2(REFERENCES) |
- |
100 |
|
............ |
| 3(Freedom From Defects) |
- |
100 |
|
............ |
| 4(Manufacture) |
- |
100 |
|
............ |
| 4.1(Manufacture) |
- |
100 |
|
............. |
| 4.2(Manufacture) |
- |
100 |
|
............... |
| 5(Type and Grades) |
- |
500 |
|
............ |
| 6(Chemical Composition) |
- |
2000 |
|
............. |
| 7(Physical Tests) |
- |
500 |
|
......... |
| 7.1(Tensile test) |
- |
2000 |
|
........ |
| 7.2(Flattening Tests) |
- |
500 |
|
...... |
| 7.3(Submerged- Are Weld Tests) |
- |
500 |
|
...... |
| 8(Hydraulic Pressure Test) |
- |
1000 |
|
........ |
| 9(Permissible variations in dimensions) |
- |
1000 |
|
........ |
| 9.1(Lengths) |
- |
500 |
|
..... |
| 9.2(Thickness and Diameter) |
- |
1000 |
|
......... |
| 10(Finish) |
- |
100 |
|
........ |
| 11(Repair by Welding) |
- |
500 |
|
........ |
| 12(Protective Coating) |
- |
500 |
|
........ |
| 13(Marking) |
- |
100 |
|
....... |
| 13.2(Bis Certification Marking) |
- |
100 |
|
...... |
| 14(Information to be supplied by the purchaser) |
- |
100 |
|
........... |
| 1(SCOPE) |
- |
100 |
|
.................. |
| 2(REFERENCES) |
- |
100 |
|
......... |
| 3(Freedom From Defects) |
- |
100 |
|
........... |
| 4(Manufacture) |
- |
100 |
|
........ |
| 4.1(Manufacture) |
- |
100 |
|
............. |
| 4.2(Manufacture) |
- |
100 |
|
............... |
| 5(Type and Grades) |
- |
200 |
|
........ |
| 6(Chemical Composition) |
- |
500 |
|
...... |
| 7(Physical Tests) |
- |
500 |
|
....... |
| 7.1(Tensile test) |
- |
500 |
|
.... |
| 7.2(Flattening Tests) |
- |
500 |
|
...... |
| 7.3(Submerged- Are Weld Tests) |
- |
500 |
|
...... |
| 8(Hydraulic Pressure Test) |
- |
500 |
|
.... |
| 9(Permissible variations in dimensions) |
- |
500 |
|
...... |
| 9.1(Lengths) |
- |
500 |
|
.............. |
| 9.2(Thickness and Diameter) |
- |
500 |
|
......... |
| 10(Finish) |
- |
500 |
|
........ |
| 11(Repair by Welding) |
- |
500 |
|
...... |
| 12(Protective Coating) |
- |
200 |
|
............. |
| 13(Marking) |
- |
100 |
|
.............. |
| 13.2(Bis Certification Marking) |
- |
100 |
|
.......... |
| 14(Information to be supplied by the purchaser) |
- |
100 |
|
....... |
| Cl. 6.1, S.No. i)(Carbon) |
- |
500 |
|
...... |
| Cl. 6.1, S.No. ii)(Sulphur) |
- |
500 |
|
.... |
| Cl. 6.1, S.No. iii)(Phosphorus) |
- |
500 |
|
............. |
| 1(SCOPE) |
- |
100 |
|
.............. |
| 2(REFERENCES) |
- |
100 |
|
.......... |
| 3(Freedom From Defects) |
- |
100 |
|
..................... |
| 4(Manufacture) |
- |
100 |
|
.................. |
| 4.1(Manufacture) |
- |
100 |
|
.................. |
| 4.2(Manufacture) |
- |
100 |
|
.................. |
| 5(Type and Grades) |
- |
500 |
|
................ |
| 6(Chemical Composition) |
- |
500 |
|
................. |
| 7(Physical Tests) |
- |
1000 |
|
................. |
| 7.1(Tensile test) |
- |
1000 |
|
.................. |
| 7.2(Flattening Tests) |
- |
1000 |
|
................. |
| 7.3(Submerged- Are Weld Tests) |
- |
1000 |
|
................... |
| 8(Hydraulic Pressure Test) |
- |
500 |
|
.................. |
| 9(Permissible variations in dimensions) |
- |
500 |
|
.................................. |
| 9.1(Lengths) |
- |
500 |
|
.................... |
| 9.2(Thickness and Diameter) |
- |
500 |
|
................... |
| 10(Finish) |
- |
100 |
|
................... |
| 11(Repair by Welding) |
- |
200 |
|
.................. |
| 12(Protective Coating) |
- |
200 |
|
.................. |
| 13(Marking) |
- |
100 |
|
.................. |
| 13.2(Bis Certification Marking) |
- |
100 |
|
.................... |
| 14(Information to be supplied by the purchaser) |
- |
500 |
|
.................. |
| Cl. 6.1, S.No. i)(Carbon) |
- |
200 |
|
.................... |
| Cl. 6.1, S.No. ii)(Sulphur) |
- |
200 |
|
................... |
| Cl. 6.1, S.No. iii)(Phosphorus) |
- |
20 |
|
.......................... |
|
07 Sep, 2028 |
- included w.e.f 01.04.2026 |
| 1313 |
Unique Test House LLP
| 9134536
| IS 7378 (1974) |
Bed, Fowler's, Hospital |
ALL SIZES |
11000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 2.1(Flais, Angles and Strips) |
- |
1000 |
|
.............. |
| 2.2(Castings) |
- |
1000 |
|
............ |
| 2.3(Tubings) |
- |
1000 |
|
.............. |
| 2.4(Shoes) |
- |
500 |
|
...................... |
| 2.5(Castors) |
- |
500 |
|
.............. |
| 3(Shape and Dimensions) |
- |
2000 |
|
.......... |
| 4(Manufacture) |
- |
200 |
|
........ |
| 5(Workmanship) |
- |
200 |
|
........... |
| 6(Finish) |
- |
200 |
|
.... |
| 7.1(Impact test) |
- |
1000 |
|
.............. |
| 7.2(Mattress test) |
- |
1000 |
|
........... |
| 7.3(Adhesion Test) |
- |
1000 |
|
.................. |
| 7.3(Performance Test) |
- |
1000 |
|
............... |
| 8(Marking) |
- |
200 |
|
.............. |
| 9(Packing) |
- |
200 |
|
................. |
| 2.1(Flais, Angles and Strips) |
- |
500 |
|
................ |
| 2.2(Castings) |
- |
500 |
|
...................... |
| 2.3(Tubings) |
- |
500 |
|
......................... |
| 2.4(Shoes) |
- |
100 |
|
...................... |
| 2.5(Castors) |
- |
500 |
|
....................... |
| 3(Shape and Dimensions) |
- |
500 |
|
........................ |
| 4(Manufacture) |
- |
100 |
|
...................... |
| 5(Workmanship) |
- |
100 |
|
...................... |
| 6(Finish) |
- |
100 |
|
................... |
| 7.1(Impact test) |
- |
500 |
|
.................... |
| 7.2(Mattress test) |
- |
500 |
|
..................... |
| 7.3(Adhesion Test) |
- |
100 |
|
................... |
| 7.3(Performance Test) |
- |
100 |
|
.................... |
| 8(Marking) |
- |
100 |
|
................... |
| 9(Packing) |
- |
100 |
|
................. |
| 2.1(Flais, Angles and Strips) |
- |
1000 |
|
........................ |
| 2.2(Castings) |
- |
500 |
|
......................... |
| 2.3(Tubings) |
- |
500 |
|
.................... |
| 2.4(Shoes) |
- |
500 |
|
................... |
| 2.5(Castors) |
- |
400 |
|
.................. |
| 3(Shape and Dimensions) |
- |
500 |
|
................. |
| 4(Manufacture) |
- |
100 |
|
................ |
| 5(Workmanship) |
- |
100 |
|
................. |
| 6(Finish) |
- |
100 |
|
................ |
| 7.1(Impact test) |
- |
500 |
|
................ |
| 7.2(Mattress test) |
- |
500 |
|
................ |
| 7.3(Adhesion Test) |
- |
500 |
|
................ |
| 7.3(Performance Test) |
- |
100 |
|
................. |
| 8(Marking) |
- |
100 |
|
................ |
| 9(Packing) |
- |
100 |
|
................. |
|
07 Sep, 2028 |
- included w.e.f 01.04.2026 |
| 1314 |
S.B.Steels Company, Bally
| 5120906
| IS 10748 (2025) |
Hot-Rolled Steel Strip for Welded Tubes and Pipes - Specification ( Third Revision) |
- |
16000.00 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl-8.3, Table-5 & 6(Tensile Strength, MPa) |
- |
500.00 |
|
- |
| Cl-8.3, Table-5 & 6(Yield Strength, MPa) |
- |
500.00 |
|
- |
| Cl-9.2(Bend test) |
- |
500.00 |
|
- |
| Cl-11(freedam from Defects) |
- |
500.00 |
|
- |
| Cl-12(Dimensions) |
- |
3000.00 |
|
- |
| Cl-14(Calculation of Mass) |
- |
500.00 |
|
- |
| Cl-7.1, 7.2, 7.3 & 7.4(Carbon) |
- |
500.0 |
|
- |
| Cl-7.1, 7.2, 7.3 & 7.4(Manganese) |
- |
500.00 |
|
- |
| Cl-7.1, 7.2, 7.3 & 7.4(Sulphur) |
- |
500.00 |
|
- |
| Cl-7.1, 7.2, 7.3 & 7.4(Phosphorus) |
- |
500.00 |
|
- |
| Cl-7.1, 7.2, 7.3 & 7.4(Carbon Equivalent Value (CEV)) |
- |
1000.00 |
|
- |
| Cl-7.1, 7.2, 7.3 & 7.4(silicon) |
- |
500.00 |
|
- |
| Cl-7.1, 7.2, 7.3 & 7.4(aluminium) |
- |
500.00 |
|
- |
| Cl-7.1, 7.2, 7.3 & 7.4(Niobium) |
- |
500.00 |
|
- |
| Cl-7.1, 7.2, 7.3 & 7.4(Vanadium) |
- |
500.00 |
|
- |
| Cl-7.1, 7.2, 7.3 & 7.4(Titanium) |
- |
500.00 |
|
- |
| Cl-7.1, 7.2, 7.3 & 7.4(Nitrogen) |
- |
1500.00 |
|
- |
| Cl-7.1, 7.2, 7.3 & 7.4(Copper) |
- |
500.00 |
|
- |
| Cl-7.1, 7.2, 7.3 & 7.4(Mo + Cr +W) |
- |
1500.00 |
|
- |
| Cl-7.1, 7.2, 7.3 & 7.4(Mo) |
- |
500.00 |
|
- |
| Cl-7.1, 7.2, 7.3 & 7.4(Boron) |
- |
500.00 |
|
- |
| Cl-7.1, 7.2, 7.3 & 7.4(Nickel) |
- |
500.00 |
|
- |
| Cl-7.1, 7.2, 7.3 & 7.4(Chromium) |
- |
500.00 |
|
- |
| Cl-8.3, Table-5 & 6(Elongation at Gauge Length,) |
- |
500.00 |
|
- |
| Cl-8.3, Table-5 & 6(Tensile Strength, MPa) |
- |
500.00 |
|
- |
| Cl-8.3, Table-5 & 6(Yield Strength, MPa) |
- |
500.00 |
|
- |
| Cl-9.2(Bend test) |
- |
500.00 |
|
- |
| Cl-11(freedam from Defects) |
- |
500.00 |
|
- |
| Cl-12(Dimensions) |
- |
3000.00 |
|
- |
| Cl-14(Calculation of Mass) |
- |
500.00 |
|
- |
| Cl-7.1, 7.2, 7.3 & 7.4(Carbon) |
- |
500.00 |
|
- |
| Cl-7.1, 7.2, 7.3 & 7.4(Manganese) |
- |
500.00 |
|
- |
| Cl-7.1, 7.2, 7.3 & 7.4(Sulphur) |
- |
500.00 |
|
- |
| Cl-7.1, 7.2, 7.3 & 7.4(Phosphorus) |
- |
500.00 |
|
- |
| Cl-7.1, 7.2, 7.3 & 7.4(Carbon Equivalent Value (CEV)) |
- |
1000.00 |
|
- |
| Cl-7.1, 7.2, 7.3 & 7.4(silicon) |
- |
500.00 |
|
- |
| Cl-7.1, 7.2, 7.3 & 7.4(aluminium) |
- |
500.00 |
|
- |
| Cl-7.1, 7.2, 7.3 & 7.4(Niobium) |
- |
500.00 |
|
- |
| Cl-7.1, 7.2, 7.3 & 7.4(Vanadium) |
- |
500.00 |
|
- |
| Cl-7.1, 7.2, 7.3 & 7.4(Titanium) |
- |
500.00 |
|
- |
| Cl-7.1, 7.2, 7.3 & 7.4(Nitrogen) |
- |
1500.00 |
|
- |
| Cl-7.1, 7.2, 7.3 & 7.4(Copper) |
- |
500.00 |
|
- |
| Cl-7.1, 7.2, 7.3 & 7.4(Mo + Cr +W) |
- |
1500.00 |
|
- |
| Cl-7.1, 7.2, 7.3 & 7.4(Mo) |
- |
500.00 |
|
- |
| Cl-7.1, 7.2, 7.3 & 7.4(Boron) |
- |
500.00 |
|
- |
| Cl-7.1, 7.2, 7.3 & 7.4(Nickel) |
- |
500.00 |
|
- |
| Cl-7.1, 7.2, 7.3 & 7.4(Chromium) |
- |
500.00 |
|
- |
| Cl-8.3, Table-5 & 6(Elongation at Gauge Length,) |
- |
500.00 |
|
- |
| Cl-8.3, Table-5 & 6(Tensile Strength, MPa) |
- |
500.00 |
|
- |
| Cl-8.3, Table-5 & 6(Yield Strength, MPa) |
- |
500.00 |
|
- |
| Cl-9.2(Bend test) |
- |
500.00 |
|
- |
| Cl-11(freedam from Defects) |
- |
500.00 |
|
- |
| Cl-12(Dimensions) |
- |
3000.00 |
|
- |
| Cl-14(Calculation of Mass) |
- |
500.00 |
|
- |
| Cl-7.1, 7.2, 7.3 & 7.4(Carbon) |
- |
500.00 |
|
- |
| Cl-7.1, 7.2, 7.3 & 7.4(Manganese) |
- |
500.00 |
|
- |
| Cl-7.1, 7.2, 7.3 & 7.4(Sulphur) |
- |
500.00 |
|
- |
| Cl-7.1, 7.2, 7.3 & 7.4(Phosphorus) |
- |
500.00 |
|
- |
| Cl-7.1, 7.2, 7.3 & 7.4(Carbon Equivalent Value (CEV)) |
- |
1000.00 |
|
- |
| Cl-7.1, 7.2, 7.3 & 7.4(silicon) |
- |
500.00 |
|
- |
| Cl-7.1, 7.2, 7.3 & 7.4(aluminium) |
- |
500.00 |
|
- |
| Cl-7.1, 7.2, 7.3 & 7.4(Niobium) |
- |
500.00 |
|
- |
| Cl-7.1, 7.2, 7.3 & 7.4(Vanadium) |
- |
500.00 |
|
- |
| Cl-7.1, 7.2, 7.3 & 7.4(Titanium) |
- |
500.00 |
|
- |
| Cl-7.1, 7.2, 7.3 & 7.4(Nitrogen) |
- |
1500.00 |
|
- |
| Cl-7.1, 7.2, 7.3 & 7.4(Copper) |
- |
500.00 |
|
- |
| Cl-7.1, 7.2, 7.3 & 7.4(Mo + Cr +W) |
- |
1500.00 |
|
- |
| Cl-7.1, 7.2, 7.3 & 7.4(Mo) |
- |
500.00 |
|
- |
| Cl-7.1, 7.2, 7.3 & 7.4(Boron) |
- |
500.00 |
|
- |
| Cl-7.1, 7.2, 7.3 & 7.4(Nickel) |
- |
500.00 |
|
- |
| Cl-7.1, 7.2, 7.3 & 7.4(Chromium) |
- |
500.00 |
|
- |
| Cl-8.3, Table-5 & 6(Elongation at Gauge Length,) |
- |
500.00 |
|
- |
|
06 Sep, 2027 |
- Included w.e.f. 24.03.2026 |
| 1315 |
Dashmesh Test Lab Private Limited
| 8186926
| IS 3315 (2024) |
Direct Evaporative Air Cooler â Specification (Fourth Revision) |
ALL TYPE |
37500 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl-5.1(Enclosure) |
- |
500 |
|
- |
| Cl-5.2(Filter Pads) |
- |
500 |
|
- |
| Cl-5.3(Sump Tank Capacities) |
- |
500 |
|
- |
| Cl-5.4(Blower/Fan) |
- |
500 |
|
- |
| Cl-5.4.3(Fan motor) |
- |
500 |
|
- |
| Cl-5.5(Pump Set) |
- |
500 |
|
- |
| Cl-5.6.1(Electrical wiring and connection) |
- |
500 |
|
- |
| Cl-5.6.2(Suitable power cable) |
- |
500 |
|
- |
| Cl-5.7(Switches) |
- |
500 |
|
- |
| Cl-6(Rating Requirement) |
- |
500 |
|
- |
| Cl-8.1(Performance Requirement) |
- |
5000 |
|
- |
| Cl-8.2(Sound Test) |
- |
2000 |
|
- |
| Cl-8.3(Air Delivery (Air Flow) Test) |
- |
3000 |
|
- |
| Cl-8.4(Cooling Efficiency Test) |
- |
5000 |
|
- |
| Cl-8.5(Power Consumption) |
- |
5000 |
|
- |
| Cl-8.6(EER Calculation Method) |
- |
5000 |
|
- |
| Cl-8.7(Drop Test) |
- |
500 |
|
- |
| Cl-8.8(Air Cooler Blower/Fan Reliability Test) |
- |
5000 |
|
- |
| Cl-12.2.1(General Running Tests) |
- |
500 |
|
- |
| Cl-12.2.2(Protection against Electric Shock) |
- |
200 |
|
- |
| Cl-12.2.3(High Voltage Tests) |
- |
500 |
|
- |
| Cl-12.2.4(Leakage Current) |
- |
200 |
|
- |
| Cl-12.2.5(Provision for Earthing) |
- |
100 |
|
- |
| Cl-12.2.6(Finish) |
- |
300 |
|
- |
| Cl-13(Additional Requirement for ECO-Mark) |
- |
0 |
|
- |
| Cl-14(Storage) |
- |
200 |
|
- |
|
22 Jul, 2028 |
- - |
| 1316 |
Atharva Laboratories Pvt. Ltd. (C-54), Noida
| 8165026
| IS 15844 : Part 1 (2023) |
SPORTS FOOTWEAR PART -1 GENERAL PURPOSEFirst Revision |
- |
64000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl No.4.1(Sampling and Conditioning) |
- |
600 |
|
- |
| Cl No.4.2(Construction) |
- |
150 |
|
- |
| Cl No.4.3(Whole Footwear) |
- |
250 |
|
- |
| 4.3.1(Insole) |
- |
250 |
|
- |
| 4.3.2(Toe spring height) |
- |
500 |
|
- |
| 4.3.3(Upper to Mid Sole/Out Sole Bond Performance) |
- |
1000 |
|
- |
| 4.3.4("Upper to Composite Sole Bond Performance
(Applicable Only When the Sole is Composite)") |
- |
1000 |
|
- |
| 4.3.5(Out Sole to Mid Sole (Multilayer) Bond Performance) |
- |
1000 |
|
- |
| 4.3.6(Energy Absorption at Seat Region) |
- |
1500 |
|
- |
| 4.3.7(Complete Shoe Flexing) |
- |
1500 |
|
- |
| 4.3.8(Washability) |
- |
0 |
|
- |
| 4.3.9(Slip Resistance) |
- |
2500 |
|
- |
| Cl No.4.4 , Table No. 2 , i) , a)(Flexing resistance, Dry condition) |
- |
1500 |
|
- |
| Cl No.4.4 , Table No. 2 , i) , b)(Flexing resistance, Wet condition) |
- |
1500 |
|
- |
| Cl No.4.4 , Table No. 2 , ii)(Tear strength (average force), Min, N) |
- |
1000 |
|
- |
| Cl No.4.4 , Table No. 2 , iii) , a)("Colour fastness rubbing (To and fro) Grey scale rate, Min ,
Dry: (rubbing) Rating: (Marring and staining) ") |
- |
1500 |
|
- |
| Cl No.4.4 , Table No. 2 , iii) , b)("Colour fastness rubbing (To and fro) Grey scale rate, Min ,
Wet: (rubbing) Rating: (Marring and staining)") |
- |
1500 |
|
- |
| Cl No.4.4 , Table No. 2 , iv) , a)(Water vapour permeability, mg/cm2h, Min) |
- |
1200 |
|
- |
| Cl No.4.4 , Table No. 2 , iv) , b)(Water vapour coefficient, mg/cm2 , Min) |
- |
1200 |
|
- |
| Cl No.4.4 , Table No. 2 , v)(Stitch tear strength (double hole), N/mm, Min) |
- |
1000 |
|
- |
| Cl No.4.4 , Table No. 2 , vi)("Colour fastness to light (Optional) Grey scale rate,
Min Rating: (Marring)") |
- |
0 |
|
- |
| Cl No.4.4 , Table No. 2 , i)(Breaking strength, N/mm, Min) |
- |
1000 |
|
- |
| Cl No.4.4 , Table No. 2 , ii)(Elongation at break, percent Min) |
- |
1000 |
|
- |
| Cl No.4.4 , Table No. 2 , iii)(Tear strength, N, Min For Fabric: For all other materials) |
- |
1000 |
|
- |
| Cl No.4.4 , Table No. 2 , iv) , a)(Flexing resistance, Dry condition) |
- |
1500 |
|
- |
| Cl No.4.4 , Table No. 2 , iv) , b)(Flexing resistance, ,Wet condition) |
- |
1500 |
|
- |
| Cl No.4.4 , Table No. 2 , v) , a)(Water vapour permeability, mg/cm2h, Min) |
- |
1200 |
|
- |
| Cl No.4.4 , Table No. 2 , v) , b)("Water vapour coefficient, mg/cm2 , Min
") |
- |
1200 |
|
- |
| Cl No.4.4 , Table No. 2 , vi)(Hydrolysis resistance) |
- |
2500 |
|
- |
| Cl No.4.4 , Table No. 2 , vii)(Bursting Strength, kg/cm2 , Min) |
- |
1200 |
|
- |
| Cl No.4.5 , Table No. 3 , i)(Tear strength, N, Min) |
- |
1000 |
|
- |
| Cl No.4.5 , Table No. 3 , ii)(Abrasion resistance, cycles) |
- |
1500 |
|
- |
| Cl No.4.5 , Table No. 3 , iii)("Colour fastness to rubbing (crocking), Grey scale
rate with 10 rubs on dry or wet, Min") |
- |
1500 |
|
- |
| Cl No.4.5 , Table No. 3 , iv)("Colour fastness to perspiration (contact method)
Grey scale rate, Min") |
- |
1500 |
|
- |
| Cl No.4.5 , Table No. 3 , v) , a)(Water vapour permeability, mg/cm2h, Min) |
- |
1200 |
|
- |
| Cl No.4.5 , Table No. 3 , v) , b)("Water vapour coefficient, mg/cm2 , Min
") |
- |
1200 |
|
- |
| Cl No.4.6 , Table No. 4 , i)(Thickness, mm, Min) |
- |
400 |
|
- |
| Cl No.4.6 , Table No. 4 , ii)(Flexing index, Min) |
- |
1500 |
|
- |
| Cl No.4.6 , Table No. 4 , iii)(Abrasion resistance, at 400 cycles) |
- |
500 |
|
- |
| Cl No.4.6 , Table No. 4 , iv) , a)(Water Absorption, mg/cm2 , Min) |
- |
1200 |
|
- |
| Cl No.4.6 , Table No. 4 , iv) , b)(Water Desorption, percent, Min) |
- |
1200 |
|
- |
| Cl No.4.7, Table No. 5 , i)(Thickness, mm, Min) |
- |
400 |
|
- |
| Cl No.4.7, Table No. 5 , ii)(Abrasion resistance, cycles) |
- |
1500 |
|
- |
| Cl No.4.7, Table No. 5 , iii) , a)(Water Absorption, mg/cm2 , Min) |
- |
1200 |
|
- |
| Cl No.4.7, Table No. 5 , iii) , b)(Water Desorption, percent, Min) |
- |
1200 |
|
- |
| Cl No.4.8 , Table No. 6 , i)(Abrasion resistance (Volume loss), mm3 , Max) |
- |
2000 |
|
- |
| Cl No.4.8 , Table No. 6 , ii)("Flexing resistance Belt Method at 90 diameter Mandrel
or
Bennewart method, cut growth, Max") |
- |
1200 |
|
- |
| Cl No.4.8 , Table No. 6 , iii)("Hydrolysis resistance, cut growth after 150 000
flexes, in mm, Max") |
- |
2500 |
|
- |
| Cl No.4.9 , Table No. 7 , i)(Compression set, percent, Max) |
- |
1500 |
|
- |
| Cl No.4.9 , Table No. 7 , ii)(Split tear strength, kg/25 mm, Min) |
- |
1000 |
|
- |
| Cl No.4.9 , Table No. 7 , iii)(Heat shrinkage, percent, Max) |
- |
1500 |
|
- |
| Cl No.4.10 , Table No. 8 , i)(First dry collapsing load, hardness, N, Min) |
- |
1000 |
|
- |
| Cl No.4.10 , Table No. 8 , ii)(Resilience, percent, Min) |
- |
1000 |
|
- |
| Cl No.4.10 , Table No. 8 , iii)(Moisture resistance, percent, Min) |
- |
1000 |
|
- |
| Cl No.4.10 , Table No. 8 , iv) , a)(Initial dry area shape retention, percent, Min) |
- |
1000 |
|
- |
| Cl No.4.10 , Table No. 8 , iv) , b)(Area shape retention after 10th collapse, dry, percent, Min) |
- |
1000 |
|
- |
| Cl No.4.11 , Table No. 9 , i)(Peel strength, N/mm, Min) |
- |
1200 |
|
- |
| Cl No.4.11 , Table No. 9 , ii)(Shear strength, kPa , Min) |
- |
1500 |
|
- |
| Cl No.4.12 , Table No. 10 , i)(Limit of useful extension, percent, Min) |
- |
1500 |
|
- |
| Cl No.4.13 , Table No. 11 , i)(Breaking strength of lace, N, Min) |
- |
1000 |
|
- |
| Cl No.4.13 , Table No. 11 , ii)(Lace tag strength, N, Min) |
- |
1000 |
|
- |
| Cl No.4.13 , Table No. 11 , iii)(Lace to lace abrasion,) |
- |
1200 |
|
- |
| Cl No.4.13 , Table No. 11 , iv)("Colour fastness to water
Gray Scale Rate, Min Rating") |
- |
1500 |
|
- |
| Cl No.4.13 , Table No. 11 , v)(Strength of Buckle/Ski hook, N, Min) |
- |
1000 |
|
- |
| Cl No.4.13 , Table No. 11 , vi)(Corrosion resistance) |
- |
1500 |
|
- |
| Cl No . 4.14("Chemical Requirement on Complete Product
for all Types of Sports Shoe") |
- |
30000 |
|
For Complete Chemical Testing |
| Cl No . 5(MARKING AND PACKING) |
- |
100 |
|
- |
| Cl No . 4.14, Table no. 1 of IS 17011(i)(Allergenic and carcinogenic disperse dyes) |
- |
2500 |
|
- |
| Cl No . 4.14, Table no. 1 of IS 17011(ii)(Aromatic amines released from Azo dyes (each individual amine)) |
- |
3000 |
|
- |
| Cl No . 4.14, Table no. 1 of IS 17011(iii)(Aromatic amines released from Azo dyes (each individual amine)) |
- |
3000 |
|
- |
| Cl No . 4.14, Table no. 1 of IS 17011(iv)(Chromium (VI)) |
- |
1500 |
|
- |
| Cl No . 4.14, Table no. 1 of IS 17011(v)(Dimethyl fumarate (DMFU)) |
- |
4500 |
|
- |
| Cl No . 4.14, Table no. 1 of IS 17011(vi)(Formaldehyde (free or released by partial hydrolysis)) |
- |
4500 |
|
- |
| Cl No . 4.14, Table no. 1 of IS 17011(vii)(Formaldehyde) |
- |
4500 |
|
- |
| Cl No . 4.14, Table no. 1 of IS 17011(viii)(Organotin compounds) |
- |
3000 |
|
- |
| Cl No . 4.14, Table no. 1 of IS 17011(ix)(PCP-TeCP-TriCP polychlorophenols) |
- |
3000 |
|
- |
| Cl No . 4.14, Table no. 1 of IS 17011(x)(pH) |
- |
800 |
|
- |
| Cl No . 4.14, Table no. 1 of IS 17011(xi)(Phthalates (each individual phthalate)) |
- |
2500 |
|
- |
| Cl No . 4.14, Table no. 1 of IS 17011(xii)(Nickel, on skin contact 2-(thiocyanomethylthio) -benzothiazole (TCMTB)) |
- |
4500 |
|
- |
| Clause 4.2 - 4.2.1(Construction) |
- |
250 |
|
- |
| Clause 4.2 - 4.2.2(Construction) |
- |
250 |
|
- |
| Clause 4.3 - 4.3.1(Whole Footwear) |
- |
250 |
|
- |
| Clause 4.3 - 4.3.2(Whole Footwear) |
- |
250 |
|
- |
| Clause 4.3 - 4.3.3(Upper to Mid Sole/Out Sole Bond Performance) |
- |
1000 |
|
- |
| Clause 4.3 - 4.3.4(Upper to Composite Sole Bond Performance(Applicable Only When the Sole is Composite)) |
- |
1000 |
|
- |
| Clause 4.3 - 4.3.5(Out Sole to Mid Sole (Multilayer) Bond) |
- |
1000 |
|
- |
| Clause 4.3 - 4.3.7(Complete Shoe Flexing) |
- |
1500 |
|
- |
| Clause 4.4, Table 1 ii)(Tear strength) |
- |
1000 |
|
- |
| Clause 4.4, Table 1 iv)-a(Water Vapour Permeability) |
- |
1200 |
|
- |
| Clause 4.4, Table 1 iv)-b(Water Vapour Coeffecient) |
- |
1200 |
|
- |
| Clause 4.4, Table 1 v)(Stitch Tear Strength(Double Hole)) |
- |
1200 |
|
- |
| Clause 4.4, Table 2 i)(Breaking Strength) |
- |
1000 |
|
- |
| Clause 4.4, Table 2 ii)(Elongation at break) |
- |
1000 |
|
- |
| Clause 4.4, Table 2 iii)(Tear strength) |
- |
1000 |
|
- |
| Clause 4.4, Table 2 v)-a(Water Vapour Permeability) |
- |
1200 |
|
- |
| Clause 4.4, Table 2 v)-b(Water Vapour Coeffecient) |
- |
1200 |
|
- |
| Clause 4.5, Table 3 i)(Tear strength) |
- |
1000 |
|
- |
| Clause 4.5, Table 3 ii)(Abrasion Resistance) |
- |
1500 |
|
- |
| Clause 4.5, Table 3 v)-a(Water Vapour Permeability) |
- |
1200 |
|
- |
| Clause 4.5, Table 3 v)-b(Water Vapour Coeffecient) |
- |
1200 |
|
- |
| Clause 4.6, Table 4 i)(Thickness) |
- |
400 |
|
- |
| Clause 4.6, Table 4 ii)(Abrasion Resistance) |
- |
1200 |
|
- |
| Clause 4.6, Table 4 iv)-b(Water Desorption) |
- |
1200 |
|
- |
| Clause 4.7, Table 5 i)(Thickness) |
- |
400 |
|
- |
| Clause 4.7, Table 5 ii)(Abrasion Resistance) |
- |
1200 |
|
- |
| Clause 4.7, Table 5 iii)-a(Water Absorption) |
- |
1200 |
|
- |
| Clause 4.7, Table 5 iii)-b(Water Desorption) |
- |
1200 |
|
- |
| Clause 4.8, Table 6 i)(Abrasion Resistance) |
- |
1500 |
|
- |
| Clause 4.8, Table 6 ii)(Flexing Resistance) |
- |
1500 |
|
- |
| Clause 4.8, Table 6 iii)(Hydrolysis Resistance) |
- |
2500 |
|
- |
| Clause 4.9, Table 7 ii)(Split Tear strength) |
- |
1200 |
|
- |
| Clause 4.9, Table 7 iii)(Heat shrinkage) |
- |
1500 |
|
- |
| Cl-5, Table -1 S. No-(i) (Amendment No-1)(Insole) |
- |
250 |
|
- |
| Cl-5, Table -1 S. No- (ii) (Amendment No-1)(Toe spring height) |
- |
500 |
|
- |
| Cl-5, Table -1 S. No- (iii) (Amendment No-1)("Bond performance
(a) Upper to sole/mid sole/composite sole
(b) Interlayer bond strength") |
- |
1000 |
|
- |
| Cl-5, Table -1 S. No- (iv) (Amendment No-1)(Energy absorption at seat region) |
- |
1500 |
|
- |
| Cl-5, Table -1 S. No- (v) (Amendment No-1)(Complete shoe flexing) |
- |
1500 |
|
- |
| Cl-5, Table -1 S. No-(vi) (Amendment No-1)(Washability) |
- |
0 |
|
- |
| Cl-5, Table -1 S. No- (vii) (Amendment No-1)(Slip resistance, coefficient of friction (COF),) |
- |
2500 |
|
- |
| Cl-5, Table -1 S. No- (viii) (Amendment No-1)("Abrasion resistance
a-Cellular sole
b-Solid sole") |
- |
2000 |
|
- |
| Cl-5, Table -1 S. No- (x) (Amendment No-1)(Chemical requirements) |
- |
30000 |
|
- |
| Cl-5, Table -1 S. No- (xi) (Amendment No-1)(Hydrolysis resistance) |
- |
2500 |
|
- |
| Cl-5, Table -1 S. No- (xii) (Amendment No-1)(Lead content) |
- |
800 |
|
- |
| Cl-6, Table -2 S. No- (i) (Amendment No-1)(Tear strength) |
- |
1000 |
|
- |
| Cl-6, Table -2 S. No- (ii) (Amendment No-1)("Colour fastness rubbing
a-Dry: (rubbing)
b-Wet: (rubbing)") |
- |
1500 |
|
- |
| Cl-6, Table -2 S. No- (iii), a) (Amendment No-1)(Water vapour permeability) |
- |
1200 |
|
- |
| Cl-6, Table -2 S. No- (iii), b) (Amendment No-1)(Water vapour coefficient) |
- |
1200 |
|
- |
| Cl-6, Table -2 S. No- (iv),(Amendment No-1)(Stitch tear strength) |
- |
1000 |
|
- |
| Cl-6, Table -2 S. No- (v),(Amendment No-1)(Colour fastness to light grey scale rate,) |
- |
0 |
|
- |
| Cl-6, Table -3 S. No- (i),(Amendment No-1)(Breaking strength, N/mm, Min) |
- |
1000 |
|
- |
| Cl-6, Table -3 S. No- (ii),(Amendment No-1)("Elongation at break
a-Tighter direction
b-Stretch direction") |
- |
1000 |
|
- |
| Cl-6, Table -3 S. No- (iii),(Amendment No-1)("Tear strength, N, Min
a) For fabric
b) For all other materials") |
- |
1000 |
|
- |
| Cl-6, Table -3 S. No- (iv),(Amendment No-1)("Flexing resistance
a- Dry condition
b-Wet condition") |
- |
1500 |
|
- |
| Cl-6, Table -3 S. No- (v), a (Amendment No-1)(Water vapour permeability) |
- |
1200 |
|
- |
| Cl-6, Table -3 S. No- (v), b (Amendment No-1)(Water vapour coefficient) |
- |
1200 |
|
- |
| Cl-6, Table -3 S. No- (vi), (Amendment No-1)(Hydrolysis resistance) |
- |
2500 |
|
- |
| Cl-6, Table -3 S. No- (vii), (Amendment No-1)(Bursting strength) |
- |
1200 |
|
- |
| Cl-6, Table -4 S. No- (i),(Amendment No-1)(Tear strength, N, Min) |
- |
1000 |
|
- |
| Cl-6, Table -4 S. No- (ii),(Amendment No-1)("Abrasion resistance, cycles
a- Dry condition
b-Wet condition") |
- |
1500 |
|
- |
| Cl-6, Table -4 S. No- (iii),(Amendment No-1)(Colour fastness to rubbing , grey scale rate with 10 rubs on dry or wet, Min) |
- |
1500 |
|
- |
| Cl-6, Table -4 S. No- (iv),(Amendment No-1)(Colour fastness to perspiration) |
- |
1500 |
|
- |
| Cl-6, Table -4 S. No- (v), a (Amendment No-1)(Water vapour permeability) |
- |
1200 |
|
- |
| Cl-6, Table -4 S. No- (v), b (Amendment No-1)(Water vapour coefficient) |
- |
1200 |
|
- |
| Cl-6, Table -5 S. No- (i), (Amendment No-1)(Thickness, mm, Min) |
- |
400 |
|
- |
| Cl-6, Table -5 S. No-(ii), (Amendment No-1)(Flexing index, Min) |
- |
1500 |
|
- |
| Cl-6, Table -5 S. No-(iii), (Amendment No-1)(Abrasion resistance,) |
- |
1500 |
|
- |
| Cl-6, Table -5 S. No- (iv), a (Amendment No-1)(Water absorption) |
- |
1200 |
|
- |
| Cl-6, Table -5 S. No- (iv), b (Amendment No-1)(Water desorption, percent) |
- |
1200 |
|
- |
| Cl-6, Table -6 S. No- (i), (Amendment No-1)(Thickness, mm, Min) |
- |
400 |
|
- |
| Cl-6, Table -6 S. No- (ii), (Amendment No-1)("Abrasion resistance, cycles
a- Dry condition
b-Wet condition") |
- |
1500 |
|
- |
| Cl-6, Table -6 S. No- (iii),a (Amendment No-1)(Water absorption) |
- |
1200 |
|
- |
| Cl-6, Table -6 S. No- (iv), b (Amendment No-1)(Water desorption, percent) |
- |
1200 |
|
- |
| Cl-6, Table -7 S. No- (i), (Amendment No-1)(Flexing resistance (Belt method or Bennewart method)) |
- |
1500 |
|
- |
| Cl-6, Table -7 S. No- (ii), (Amendment No-1)(Hydrolysis resistance, cut growth after flexes) |
- |
2500 |
|
- |
| Cl-6, Table -8 S. No- (i), (Amendment No-1)("Compression set, percent, Max
a) For EVA
b) For all other materials") |
- |
1500 |
|
- |
| Cl-6, Table -8 S. No- (ii), (Amendment No-1)(Split tear strength) |
- |
1000 |
|
- |
| Cl-6, Table -8 S. No- (iii), (Amendment No-1)(Heat shrinkage) |
- |
1500 |
|
- |
| Cl-6, Table -9 S. No- (i), (Amendment No-1)(First dry collapsing load, hardness) |
- |
1000 |
|
- |
| Cl-6, Table -9 S. No- (ii), (Amendment No-1)(Resilience, percent) |
- |
1000 |
|
- |
| Cl-6, Table -9 S. No- (iii), (Amendment No-1)(Moisture resistance) |
- |
1000 |
|
- |
| Cl-6, Table -9 S. No- (iv), a (Amendment No-1)(Initial dry area shape retention) |
- |
1000 |
|
- |
| Cl-6, Table -9 S. No- (iv), b (Amendment No-1)(Area shape retention after 10th collapse) |
- |
1000 |
|
- |
| Cl-6, Table -10 S. No- (i), (Amendment No-1)("Peel strength
a) Initial
b) After 5 000 wear cycles") |
- |
1000 |
|
- |
| Cl-6, Table -10 S. No- (ii), (Amendment No-1)("Shear strength
a) Initial
b) After 5 000 wear cycles") |
- |
1500 |
|
- |
| Cl-6, Table -11 S. No- (i), (Amendment No-1)(Limit of useful extension) |
- |
1500 |
|
- |
| Cl-6, Table -12 S. No- (i), (Amendment No-1)(Breaking strength of lace) |
- |
1000 |
|
- |
| Cl-6, Table -12 S. No- (ii), (Amendment No-1)(Lace tag strength) |
- |
1000 |
|
- |
| Cl-6, Table -12 S. No- (iii), (Amendment No-1)(Lace to lace abrasion) |
- |
1500 |
|
- |
| Cl-6, Table -12 S. No- (iv), (Amendment No-1)(Colour fastness to water (for lace) (contact method)) |
- |
1500 |
|
- |
| Cl-6, Table -12 S. No- (iv), (Amendment No-1)(Colour fastness to water (for lace) (contact method)) |
- |
1500 |
|
- |
| Cl-6, Table -12 S. No (v), (Amendment No-1)(Strength of buckle/ski hook) |
- |
1000 |
|
- |
| Cl-6, Table -12 S. No- (vi), (Amendment No-1)(Corrosion resistance) |
- |
2000 |
|
- |
| Cl.1.4.1 of IS 17011 (Table B Sl I )(Phthalate: DINP) |
- |
3000 |
|
- |
| Cl.1.4.1 of IS 17011 (Table B Sl II )(Phthalate:: DNOP) |
- |
3000 |
|
- |
| Cl.1.4.1 of IS 17011 (Table B Sl III )(Phthalate: DEHP) |
- |
3000 |
|
- |
| Cl.1.4.1 of IS 17011 (Table B Sl IV )(Phthalate: DIDP) |
- |
3000 |
|
- |
| Cl.1.4.1 of IS 17011 (Table B Sl V)(Phthalate: BBP) |
- |
3000 |
|
- |
| Cl.1.4.1 of IS 17011 (Table B Sl VI )(Phthalate:DBP) |
- |
3000 |
|
- |
| Cl.1.4.1 of IS 17011 (Table B Sl VII )(Phthalate: DIBP) |
- |
3000 |
|
- |
| Cl.4.1 (Annex-A Sl I )(Organotin: Dibutyltin) |
- |
3000 |
|
- |
| Cl.4.1 (Annex-A Sl II )(Organotin: Dibutyltin Dichloride) |
- |
3000 |
|
- |
| Cl.4.1 (Annex-A Sl III )(Organotin: Dioctyltin) |
- |
3000 |
|
- |
| Cl.4.1 (Annex-A Sl IV)(Organotin: Monobutyltin) |
- |
3000 |
|
- |
| Cl.4.1 (Annex-A Sl V )(Organotin: Tributyltin) |
- |
3000 |
|
- |
| Cl.4.1 (Annex-A Sl VI)(Organotin: Triphenyltin) |
- |
3000 |
|
- |
| Cl.4.1 (Annex-A Sl VII )(Organotin: Monoctyltin) |
- |
3000 |
|
- |
| Cl.4.1 (Annex-A Sl VIII)(Organotin: Bis (tributyltin) oxide) |
- |
3000 |
|
- |
| Cl.4.1 (Table B-1 Sl I)(Aromatic Amines: 4-aminobiphenyl) |
- |
3000 |
|
- |
| Cl.4.1 (Table B-1 Sl II)(Aromatic Amines: Benzidine) |
- |
3000 |
|
- |
| Cl.4.1 (Table B-1 Sl III)(Aromatic Amines: 4-chloro-o-toluidine) |
- |
3000 |
|
- |
| Cl.4.1 (Table B-1 Sl IV)(Aromatic Amines: 2-naphthylamine) |
- |
3000 |
|
- |
| Cl.4.1 (Table B-1 Sl V)(Aromatic Amines :o-aminoazotoluene) |
- |
3000 |
|
- |
| Cl.4.1 (Table B-1 Sl VI)(Aromatic Amines: 2-amino-4-nitrotoluenem) |
- |
3000 |
|
- |
| Cl.4.1 (Table B-1 Sl VII)(Aromatic Amines: p-chloroaniline) |
- |
3000 |
|
- |
| Cl.4.1 (Table B-1 Sl VIII)(Aromatic Amines: 2,4-diaminoanisole) |
- |
3000 |
|
- |
| Cl.4.1 (Table B-1 Sl IX)(Aromatic Amines : 4,4’- diaminodiphenylmethane:) |
- |
3000 |
|
- |
| Cl.4.1 (Table B-1 Sl X)(Aromatic Amines : 3,3’-dichlorobenzidine) |
- |
3000 |
|
- |
| Cl.4.1 (Table B-1 Sl XI)(Aromatic Amines : 3,3’-dimethoxybenzidine) |
- |
3000 |
|
- |
| Cl.4.1 (Table B-1 Sl XII)(Aromatic Amines : 3,3’-dimethylbenzidine) |
- |
3000 |
|
- |
| Cl.4.1 (Table B-1 Sl XIII)(Aromatic Amines: 3,3’-dimethyl-4,4’-diaminodiphenylmethane) |
- |
3000 |
|
- |
| Cl.4.1 (Table B-1 Sl XIV)(Aromatic Amines : p-cresi) |
- |
3000 |
|
- |
| Cl.4.1 (Table B-1 Sl XV)(Aromatic Amines : 4,4’-methylene-bis(2-chloroaniline):) |
- |
3000 |
|
- |
| Cl.4.1 (Table B-1 Sl XVI)(Aromatic Amines :4,4’-oxydianiline) |
- |
3000 |
|
- |
| Cl.4.1 (Table B-1 Sl XVII)(Aromatic Amines:4,4’-thiodianiline) |
- |
3000 |
|
- |
| Cl.4.1 (Table B-1 Sl XVIII)(Aromatic Amines :o-toluidine:) |
- |
3000 |
|
- |
| Cl.4.1 (Table B-1 Sl XIX)(Aromatic Amines: 2,4-toluylendiamine) |
- |
3000 |
|
- |
| Cl.4.1 (Table B-1 Sl XX)(Aromatic Amines: 2,4,5-trimethylaniline) |
- |
3000 |
|
- |
| Cl.4.1 (Table B-1 Sl XXI)(Aromatic Amines :2,4-dimethylaniline) |
- |
3000 |
|
- |
| Cl.4.1 (Table B-1 Sl XXII)(Aromatic Amines: 2,6-dimethylaniline:) |
- |
3000 |
|
- |
| Cl.4.1 (Table B-1 Sl XXIII)(Aromatic Amines :2-methoxyaniline) |
- |
3000 |
|
- |
| Cl.4.1 (Table B-1 Sl XXIV)(Aromatic Amines :4-aminoazobenzene) |
- |
3000 |
|
- |
| Cl.4.1 (Table B-3 Sl I)(Allergenic Disperse Dyes :Disperse blue 3) |
- |
3000 |
|
- |
| Cl.4.1 (Table B-3 Sl II)(Allergenic Disperse Dyes :Disperse blue 7) |
- |
3000 |
|
- |
| Cl.4.1 (Table B-3 Sl III)(Allergenic Disperse Dyes :Disperse blue 26) |
- |
3000 |
|
- |
| Cl.4.1 (Table B-3 Sl IV)(Allergenic Disperse Dyes :Disperse blue 102) |
- |
3000 |
|
- |
| Cl.4.1 (Table B-3 Sl V)(Allergenic Disperse Dyes: Disperse brown 1) |
- |
3000 |
|
- |
| Cl.4.1 (Table B-3 Sl VI)(Allergenic Disperse Dyes :Disperse yellow 1) |
- |
3000 |
|
- |
| Cl.4.1 (Table B-3 Sl VII)(Allergenic Disperse Dyes :Disperse yellow 9) |
- |
3000 |
|
- |
| Cl.4.1 (Table B-3 Sl VIII)(Allergenic Disperse Dyes :Disperse yellow 39) |
- |
3000 |
|
- |
| Cl.4.1 (Table B-3 Sl IX)(Allergenic Disperse Dyes :Disperse yellow 49) |
- |
3000 |
|
- |
| Cl.4.1 (Table B-3 Sl X)(Allergenic Disperse Dyes :Disperse orange 1) |
- |
3000 |
|
- |
| Cl.4.1 (Table B-3 Sl XI)(Allergenic Disperse Dyes :Disperse red 11) |
- |
3000 |
|
- |
| Cl.4.1 (Table B-3 Sl XII)(Allergenic Disperse Dyes :Disperse red 17) |
- |
3000 |
|
- |
| Cl.4.1 (Table B-3 Sl XIII)(Allergenic Disperse Dyes :Disperse yellow 7) |
- |
3000 |
|
- |
| Cl.4.1 (Table B-3 Sl XIV)(Allergenic Disperse Dyes :Disperse yellow 56) |
- |
3000 |
|
- |
| Cl.4.1 (Table B-3 Sl XV)(Allergenic Disperse Dyes :Disperse red 151) |
- |
3000 |
|
- |
| Cl.4.1 (Table B-3 Sl XVI)(Allergenic Disperse Dyes :Solvent red 23) |
- |
3000 |
|
- |
| Cl.4.1 (Table B-4 Sl I)(Carcinogenic Disperse Dyes :Navy blue) |
- |
3000 |
|
- |
| Cl.4.1 (Table B-4 Sl II)(Carcinogenic Disperse Dyes: Disperse blue 1) |
- |
3000 |
|
- |
| Cl.4.1 (Table B-4 Sl III)(Carcinogenic Disperse Dyes: Disperse blue 35) |
- |
3000 |
|
- |
| Cl.4.1 (Table B-4 Sl IV)(Carcinogenic Disperse Dyes :Disperse blue 106) |
- |
3000 |
|
- |
| Cl.4.1 (Table B-4 Sl V)(Carcinogenic Disperse Dyes: Disperse blue 124) |
- |
3000 |
|
- |
| Cl.4.1 (Table B-4 Sl VI)(Carcinogenic Disperse Dyes :Disperse yellow 3) |
- |
3000 |
|
- |
| Cl.4.1 (Table B-4 Sl VII)(Carcinogenic Disperse Dyes: Disperse orange 3) |
- |
3000 |
|
- |
| Cl.4.1 (Table B-4 Sl VIII)(Carcinogenic Disperse Dyes :Disperse orange 37/59/76a)) |
- |
3000 |
|
- |
| Cl.4.1 (Table B-4 Sl IX)(Carcinogenic Disperse Dyes :Disperse red 1) |
- |
3000 |
|
- |
| Cl.4.1 (Table B-4 Sl X)(Carcinogenic Disperse Dyes :Basic red 9) |
- |
3000 |
|
- |
| Cl.4.1 (Table B-4 Sl XI)(Carcinogenic Disperse Dyes :Violet 3) |
- |
3000 |
|
- |
| Cl.4.1 (Table B-4 Sl XII)(Carcinogenic Disperse Dyes Disperse yellow 23) |
- |
3000 |
|
- |
| Clause 4.6, Table 4 iv)-a(Water Absorption) |
- |
1500 |
|
- |
|
- |
- - |
| 1317 |
Urja Metallurgical Services LLP
| 7194806
| IS 12817 (2020) |
Stainless Steel Butt Hinges - Specification ( Third Revision ) |
All Grade / Type / Size / Designation / Class |
5800 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 6.2, Table 1 to 6(Length , A -IS 12817) |
- |
0 |
|
- |
| 6.2, Table 1 to 6(Breadth, B-IS 12817) |
- |
0 |
|
- |
| 6.2, Table 1 to 6(Breadth, B1-IS 12817) |
- |
0 |
|
- |
| 6.2, Table 1 to 6(Breadth, B2-IS 12817) |
- |
0 |
|
- |
| 6.2, Table 1 to 6(Thickness of flap, C-IS 12817) |
- |
0 |
|
- |
| 6.2, Table 1 to 6(Dia. of Hinge pin, D-IS 12817 ) |
- |
0 |
|
- |
| 6.2, Table 1 to 6(Number of Knuckles- IS 12817 ) |
- |
0 |
|
- |
| 6.2, Table 1 to 6(Number of Screw Holes -IS 12817 ) |
- |
0 |
|
- |
| 6.2, Table 1 to 6(Holes for Screw Number- IS 12817 ) |
- |
0 |
|
- |
| 7.1(General - IS 12817 ) |
- |
0 |
|
- |
| 7.2(Knuckles - IS 12817 ) |
- |
0 |
|
- |
| 7.3(Pins- IS 12817 ) |
- |
0 |
|
- |
| 7.4(Screw Holes- IS 12817 ) |
- |
0 |
|
- |
| 7.4.2(Position of screw holes - IS 12817 ) |
- |
0 |
|
- |
| 7.4.2, Fig 1(The distance of the screw holes from the end of the flap - IS 12817 ) |
- |
0 |
|
- |
| 8.0(Finish - IS 12817 ) |
- |
0 |
|
- |
| Clause 4.1.2(Silicon (Pin) ) |
- |
0 |
|
- |
| Clause 4.1.2(Phosphorus (Pin) ) |
- |
0 |
|
- |
| Clause 4.1.2(Sulphur (Pin) ) |
- |
0 |
|
- |
| Clause 4.1.2(Manganese (Pin) ) |
- |
0 |
|
- |
| Clause 4.1.2(Carbon (Pin) ) |
- |
0 |
|
- |
| Clause 4.1.1(Silicon (Flap) ) |
- |
0 |
|
- |
| Clause 4.1.1(Phosphorus (Flap) ) |
- |
0 |
|
- |
| Clause 4.1.1(Sulphur (Flap) ) |
- |
0 |
|
- |
| Clause 4.1.1(Manganese (Flap) ) |
- |
0 |
|
- |
| Clause 4.1.1(Carbon (Flap) ) |
- |
0 |
|
- |
| Clause 7.4.2 (Dimension - Z ) |
- |
0 |
|
- |
| Clause 7.4.2 (Dimension - Y ) |
- |
0 |
|
- |
| Clause 7.4.2 (Dimension - X ) |
- |
0 |
|
- |
| Clause 7.4.1(Number of holes) |
- |
0 |
|
- |
| As per Cl.4(Carbon) |
- |
0 |
|
- |
| As per Cl.4(Sulphur) |
- |
0 |
|
- |
| As per Cl.4(Phosphorus) |
- |
0 |
|
- |
| As per Cl.4(Manganese) |
- |
0 |
|
- |
| As per Cl.4(Nitrogen) |
- |
0 |
|
- |
| As per Cl.4(Silicon) |
- |
0 |
|
- |
| As per Cl.4(Aluminium) |
- |
0 |
|
- |
| As per Cl.4(Chromium) |
- |
0 |
|
- |
| As per Cl.4(Vanadium) |
- |
0 |
|
- |
| As per Cl.4(Molybdenum) |
- |
0 |
|
- |
| As per Cl.4(Niobium) |
- |
0 |
|
- |
| As per Cl.4(Nickel) |
- |
0 |
|
- |
| As per Cl.4(Copper) |
- |
0 |
|
- |
| As per Cl.4(Titanium) |
- |
0 |
|
- |
| As per Cl.4(Zirconium) |
- |
0 |
|
- |
| As per Cl.4(Tungsten) |
- |
0 |
|
- |
| As per Cl.4(Cerium) |
- |
0 |
|
- |
| Cl.4(Other Elements - IS 228 and its parts or any other intrumental/chemical methods) |
- |
0 |
|
- |
|
23 Dec, 2028 |
- Included w.e.f 24.02.2026 |
| 1318 |
ATCC TEST LABS LLP
| 8172626
| IS 4246 (2025) |
DOMESTIC GAS STOVE AND BUILT IN HOB FOR USE WITH LPG SPECIFICATION (Sixth Revision ) |
DOMESTIC GAS STOVE AND BUILT IN HOB FOR USE WITH LPG SPECIFICATION |
26000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4.1(General - IS 4246 : 2025) |
- |
500 |
|
- |
| 4.1(General - IS 4246 : 2025) |
- |
0 |
|
- |
| 4.1.1(General - IS 4246 : 2025) |
- |
0 |
|
- |
| 5(Materials - Cl. 5 of IS 5116) |
- |
500 |
|
- |
| 5.1.1(Materials - Toughened glass, if provided,) |
- |
500 |
|
- |
| 5.1.1(Materials - Toughened glass, if provided,) |
- |
0 |
|
- |
| 5.1.1(Materials - Toughened glass, if provided,) |
- |
0 |
|
- |
| 5.1.1(Materials - Toughened glass, if provided,) |
- |
0 |
|
- |
| 5.1.1(Materials - Toughened glass, if provided,) |
- |
0 |
|
- |
| 5.1.1(Materials - Toughened glass, if provided,) |
- |
0 |
|
- |
| 5.1.1(Materials - Toughened glass, if provided,) |
- |
0 |
|
- |
| 5.1.1(Materials - Toughened glass, if provided,) |
- |
0 |
|
- |
| 5.1.1(Materials - Toughened glass, if provided,) |
- |
0 |
|
- |
| 5.1(Materials - IS 5116) |
- |
0 |
|
- |
| 5.1(Materials - IS 5116) |
- |
0 |
|
- |
| 5.1.1(Materials - IS 5116) |
- |
0 |
|
- |
| 5.2(Materials - IS 5116) |
- |
500 |
|
- |
| 5.2(Materials - IS 5116) |
- |
0 |
|
- |
| 5.3(Materials - IS 5116) |
- |
500 |
|
- |
| 5.5(Materials - IS 5116) |
- |
500 |
|
- |
| 5.5(Materials - IS 5116) |
- |
0 |
|
- |
| 5.5(Materials - IS 5116) |
- |
0 |
|
- |
| 5.7(Materials - IS 5116) |
- |
500 |
|
- |
| 6.1(Design for Maintainance) |
- |
500 |
|
- |
| 6.1(Design for Maintainance) |
- |
0 |
|
- |
| 6.2(Design for Maintainance) |
- |
500 |
|
- |
| 6.2(Design for Maintainance) |
- |
500 |
|
- |
| 6.3(Design for Maintainance) |
- |
500 |
|
- |
| 6.4(Design for Maintainance) |
- |
500 |
|
- |
| 6.5(Design for Maintainance) |
- |
500 |
|
- |
| 6.6(Design for Maintainance) |
- |
500 |
|
- |
| 7.0(Rigidity and Stability) |
- |
500 |
|
- |
| 7.1(Rigidity and Stability) |
- |
500 |
|
- |
| 7.2(Rigidity and Stability) |
- |
500 |
|
- |
| 7.3(Rigidity and Stability) |
- |
500 |
|
- |
| 8.1(Workmanship and Finish - Cl. 7 of IS 5116) |
- |
500 |
|
- |
| 8.1(Workmanship and Finish - Cl. 7 of IS 5116) |
- |
0 |
|
- |
| 8.1(Workmanship and Finish - Cl. 7 of IS 5116) |
- |
0 |
|
- |
| 8.1(Workmanship and Finish - Cl. 7 of IS 5116) |
- |
0 |
|
- |
| 8.1(Workmanship and Finish - Cl. 7 of IS 5116) |
- |
0 |
|
- |
| 8.1(Workmanship and Finish - Cl. 7 of IS 5116) |
- |
0 |
|
- |
| 8.1(Workmanship and Finish - Cl. 7 of IS 5116) |
- |
0 |
|
- |
| 8.1(Workmanship and Finish - Cl. 7 of IS 5116) |
- |
0 |
|
- |
| 8.1(Workmanship and Finish - Cl. 7 of IS 5116) |
- |
0 |
|
- |
| 8.1(Workmanship and Finish - Cl. 7 of IS 5116) |
- |
0 |
|
- |
| 8.1(Workmanship and Finish - Cl. 7 of IS 5116) |
- |
0 |
|
- |
| 8.1(Workmanship and Finish - Cl. 7 of IS 5116) |
- |
0 |
|
- |
| 8.2(Workmanship and Finish -) |
- |
500 |
|
- |
| 8.3(Workmanship and Finish -) |
- |
500 |
|
- |
| 9(Gas Taps- Cl. 8 of IS 5116 (Except 8.7 and 8.11.1)) |
- |
500 |
|
- |
| 9(Gas Taps- Cl. 8 of IS 5116 (Except 8.7 and 8.11.1)) |
- |
0 |
|
- |
| 9(Gas Taps- Cl. 8 of IS 5116 (Except 8.7 and 8.11.1)) |
- |
0 |
|
- |
| 9(Gas Taps- Cl. 8 of IS 5116 (Except 8.7 and 8.11.1)) |
- |
0 |
|
- |
| 9(Gas Taps- Cl. 8 of IS 5116 (Except 8.7 and 8.11.1)) |
- |
0 |
|
- |
| 9(Gas Taps- Cl. 8 of IS 5116 (Except 8.7 and 8.11.1)) |
- |
0 |
|
- |
| 9(Gas Taps- Cl. 8 of IS 5116 (Except 8.7 and 8.11.1)) |
- |
0 |
|
- |
| 9(Gas Taps- Cl. 8 of IS 5116 (Except 8.7 and 8.11.1)) |
- |
0 |
|
- |
| 9(Gas Taps- Cl. 8 of IS 5116 (Except 8.7 and 8.11.1)) |
- |
0 |
|
- |
| 9(Gas Taps- Cl. 8 of IS 5116 (Except 8.7 and 8.11.1)) |
- |
0 |
|
- |
| 9(Gas Taps- Cl. 8 of IS 5116 (Except 8.7 and 8.11.1)) |
- |
0 |
|
- |
| 9(Gas Taps- Cl. 8 of IS 5116 (Except 8.7 and 8.11.1)) |
- |
0 |
|
- |
| 9(Gas Taps- Cl. 8 of IS 5116 (Except 8.7 and 8.11.1)) |
- |
0 |
|
- |
| 9(Gas Taps- Cl. 8 of IS 5116 (Except 8.7 and 8.11.1)) |
- |
0 |
|
- |
| 9(Gas Taps- Cl. 8 of IS 5116 (Except 8.7 and 8.11.1)) |
- |
0 |
|
- |
| 9(Gas Taps- Cl. 8 of IS 5116 (Except 8.7 and 8.11.1)) |
- |
0 |
|
- |
| 9(Gas Taps- Cl. 8 of IS 5116 (Except 8.7 and 8.11.1)) |
- |
0 |
|
- |
| 9(Gas Taps- Cl. 8 of IS 5116 (Except 8.7 and 8.11.1)) |
- |
0 |
|
- |
| 9(Gas Taps- Cl. 8 of IS 5116 (Except 8.7 and 8.11.1)) |
- |
0 |
|
- |
| 9(Gas Taps- Cl. 8 of IS 5116 (Except 8.7 and 8.11.1)) |
- |
0 |
|
- |
| 9(Gas Taps- Cl. 8 of IS 5116 (Except 8.7 and 8.11.1)) |
- |
0 |
|
- |
| 9(Gas Taps- Cl. 8 of IS 5116 (Except 8.7 and 8.11.1)) |
- |
500 |
|
- |
| 9(Gas Taps- Cl. 8 of IS 5116 (Except 8.7 and 8.11.1)) |
- |
0 |
|
- |
| 10(Injector Jets) |
- |
500 |
|
- |
| 10(Injector Jets) |
- |
0 |
|
- |
| 10(Injector Jets) |
- |
0 |
|
- |
| 10(Injector Jets) |
- |
0 |
|
- |
| 10(Injector Jets) |
- |
0 |
|
- |
| 10(Injector Jets) |
- |
0 |
|
- |
| 11.1(Burners- Cl. 10 of IS 5116) |
- |
500 |
|
- |
| 11.1(Burners- Cl. 10 of IS 5116) |
- |
0 |
|
- |
| 11.1(Burners- Cl. 10 of IS 5116) |
- |
0 |
|
- |
| 11.1(Burners- Cl. 10 of IS 5116) |
- |
0 |
|
- |
| 11.1(Burners- Cl. 10 of IS 5116) |
- |
0 |
|
- |
| 11.2(Burners) |
- |
500 |
|
- |
| 11.3(Burners) |
- |
500 |
|
- |
| 11.4(Burners) |
- |
500 |
|
- |
| 12.1(Burner Pan Support) |
- |
500 |
|
- |
| 12.2(Burner Pan Support) |
- |
500 |
|
- |
| 12.3(Burner Pan Support) |
- |
0 |
|
- |
| 13.1(Gas Soundness Test - Cl. 16 of IS 5116) |
- |
1000 |
|
- |
| 13,2(Gas Soundness Test) |
- |
1000 |
|
- |
| 13.2(Gas Leak Detector) |
- |
0 |
|
- |
| 14.1(Gas Inlet Connection - Cl. 18 of IS 5116) |
- |
500 |
|
- |
| 14.1(Gas Inlet Connection - Cl. 18 of IS 5116) |
- |
0 |
|
- |
| 14.1(Gas Inlet Connection - Cl. 18 of IS 5116) |
- |
0 |
|
- |
| 14.1(Gas Inlet Connection - Cl. 18 of IS 5116) |
- |
0 |
|
- |
| 14.1(Gas Inlet Connection - Cl. 18 of IS 5116) |
- |
0 |
|
- |
| 14.1(Gas Inlet Connection - Cl. 18 of IS 5116) |
- |
0 |
|
- |
| 14.1(Gas Inlet Connection - Cl. 18 of IS 5116) |
- |
0 |
|
- |
| 14.1(Gas Inlet Connection - Cl. 18 of IS 5116) |
- |
0 |
|
- |
| 14.1(Gas Inlet Connection - Cl. 18 of IS 5116) |
- |
0 |
|
- |
| 14.1(Gas Inlet Connection - Cl. 18 of IS 5116) |
- |
0 |
|
- |
| 14.1(Gas Inlet Connection - Cl. 18 of IS 5116) |
- |
0 |
|
- |
| 14.1(Gas Inlet Connection - Cl. 18 of IS 5116) |
- |
0 |
|
- |
| 14.1(Gas Inlet Connection - Cl. 18 of IS 5116) |
- |
0 |
|
- |
| 14.2(Gas Inlet Connection) |
- |
0 |
|
- |
| 14.2(Gas Inlet Connection) |
- |
500 |
|
- |
| 14.2(Gas Inlet Connection) |
- |
0 |
|
- |
| 14.2(Gas Inlet Connection) |
- |
0 |
|
- |
| 14.3(Gas Inlet Connection) |
- |
500 |
|
- |
| 14.4(Gas Inlet Connection) |
- |
500 |
|
- |
| 14.5(Gas Inlet Connection - Cl. 17.3 of IS 5116) |
- |
500 |
|
- |
| 14.6(Gas Inlet Connection) |
- |
500 |
|
- |
| 15.0(Strength and Rigidity) |
- |
500 |
|
- |
| 15.0(Strength and Rigidity) |
- |
0 |
|
- |
| 15.0(Strength and Rigidity) |
- |
0 |
|
- |
| 15.0(Strength and Rigidity) |
- |
0 |
|
- |
| 17.0(Gas Consumption Test) |
- |
5000 |
|
- |
| 17.0(Gas Consumption Test) |
- |
5000 |
|
- |
| 17.0(Gas Consumption Test) |
- |
0 |
|
- |
| 17.0(Gas Consumption Test) |
- |
0 |
|
- |
| 17.0(Gas Consumption Test) |
- |
0 |
|
- |
| 17.0(Gas Consumption Test) |
- |
0 |
|
- |
| 17.2(Gas Consumption Test - For Gas Stoves) |
- |
5000 |
|
- |
| 17.2 (a)(Gas Consumption Test - For Gas Stoves) |
- |
0 |
|
- |
| 17.2 (b)(Gas Consumption Test - For Gas Stoves) |
- |
0 |
|
- |
| 17.2 (c)(Gas Consumption Test - For Gas Stoves) |
- |
0 |
|
- |
| 17.3(Gas Consumption Test - For Built in Hobs) |
- |
5000 |
|
- |
| 17.3.1(Gas Consumption Test - For Built in Hobs) |
- |
5000 |
|
- |
| 17.3.2(Gas Consumption Test - For Built in Hobs) |
- |
5000 |
|
- |
| 18.1(Ignition and Flame Travel) |
- |
500 |
|
- |
| 18.1(Ignition and Flame Travel) |
- |
0 |
|
- |
| 18.2(Ignition and Flame Travel) |
- |
500 |
|
- |
| 18.3(Ignition and Flame Travel) |
- |
500 |
|
- |
| 18.4(Ignition and Flame Travel - Cl. 14 of IS 5116) |
- |
500 |
|
- |
| 18.4(Ignition and Flame Travel - Cl. 14 of IS 5116) |
- |
500 |
|
- |
| 18.4(Ignition and Flame Travel - Cl. 14 of IS 5116) |
- |
500 |
|
- |
| 18.4(Ignition and Flame Travel - Cl. 14 of IS 5116) |
- |
500 |
|
- |
| 18.4(Ignition and Flame Travel - Cl. 14 of IS 5116) |
- |
0 |
|
- |
| 18.4(Ignition and Flame Travel - Cl. 14 of IS 5116) |
- |
0 |
|
- |
| 19.1(Flame Stability) |
- |
1000 |
|
- |
| 19.1.1(Flame Stability) |
- |
1000 |
|
- |
| 19.2(Flame Stability) |
- |
500 |
|
- |
| 19.3(Flame Stability) |
- |
500 |
|
- |
| 20(Noise Control) |
- |
500 |
|
- |
| 21(Flash Back) |
- |
500 |
|
- |
| 22(Formation of Soot) |
- |
500 |
|
- |
| 23(Resistance to Draught) |
- |
500 |
|
- |
| 24.1(Combustion) |
- |
1000 |
|
- |
| 24.1(Combustion) |
- |
0 |
|
- |
| 24.2(Combustion) |
- |
0 |
|
- |
| 25.1(Fire Hazard and Limiting Temperatures) |
- |
2000 |
|
- |
| 25.1(Fire Hazard and Limiting Temperatures) |
- |
2000 |
|
- |
| 25.1(Fire Hazard and Limiting Temperatures) |
- |
0 |
|
- |
| 25.1(Fire Hazard and Limiting Temperatures) |
- |
0 |
|
- |
| 25.2(Fire Hazard and Limiting Temperatures) |
- |
0 |
|
- |
| 26.1(Thermal Efficiency- Gas Stoves) |
- |
5000 |
|
- |
| 26.1(Thermal Efficiency- Gas Stoves) |
- |
5000 |
|
- |
| 26.1(Thermal Efficiency- Gas Stoves) |
- |
0 |
|
- |
| 26.1(Thermal Efficiency- Gas Stoves) |
- |
0 |
|
- |
| 26.1(Thermal Efficiency- Gas Stoves) |
- |
0 |
|
- |
| 26.2(Thermal Efficiency- For Built in Hobs) |
- |
5000 |
|
- |
| 26.2(Thermal Efficiency- For Built in Hobs) |
- |
5000 |
|
- |
| 26.2(Thermal Efficiency- For Built in Hobs) |
- |
5000 |
|
- |
| 26.2(Thermal Efficiency- For Built in Hobs) |
- |
5000 |
|
- |
| 26.2(Thermal Efficiency- For Built in Hobs) |
- |
5000 |
|
- |
| 5.1.1(Materials - IS 5116) |
- |
1000 |
|
- |
| 4.1(General - IS 4246 : 2025) |
- |
500 |
|
- |
| 4.1(General - IS 4246 : 2025) |
- |
0 |
|
- |
| 4.1.1(General - IS 4246 : 2025) |
- |
0 |
|
- |
| 5(Materials - Cl. 5 of IS 5116) |
- |
500 |
|
- |
| 5.1.1(Materials - Toughened glass, if provided,) |
- |
0 |
|
- |
| 5.1.1(Materials - Toughened glass, if provided,) |
- |
0 |
|
- |
| 5.1.1(Materials - Toughened glass, if provided,) |
- |
0 |
|
- |
| 5.1.1(Materials - Toughened glass, if provided,) |
- |
0 |
|
- |
| 5.1.1(Materials - Toughened glass, if provided,) |
- |
0 |
|
- |
| 5.1.1(Materials - Toughened glass, if provided,) |
- |
0 |
|
- |
| 5.1.1(Materials - Toughened glass, if provided,) |
- |
0 |
|
- |
| 5.1.1(Materials - Toughened glass, if provided,) |
- |
0 |
|
- |
| 5.1.1(Materials - Toughened glass, if provided,) |
- |
0 |
|
- |
| 5.1(Materials - IS 5116) |
- |
0 |
|
- |
| 5.1(Materials - IS 5116) |
- |
0 |
|
- |
| 5.1.1(Materials - IS 5116) |
- |
0 |
|
- |
| 5.2(Materials - IS 5116) |
- |
500 |
|
- |
| 5.2(Materials - IS 5116) |
- |
0 |
|
- |
| 5.3(Materials - IS 5116) |
- |
500 |
|
- |
| 5.5(Materials - IS 5116) |
- |
0 |
|
- |
| 5.5(Materials - IS 5116) |
- |
500 |
|
- |
| 5.5(Materials - IS 5116) |
- |
0 |
|
- |
| 5.7(Materials - IS 5116) |
- |
500 |
|
- |
| 6.1(Design for Maintainance) |
- |
500 |
|
- |
| 6.1(Design for Maintainance) |
- |
0 |
|
- |
| 6.2(Design for Maintainance) |
- |
0 |
|
- |
| 6.2(Design for Maintainance) |
- |
0 |
|
- |
| 6.3(Design for Maintainance) |
- |
500 |
|
- |
| 6.4(Design for Maintainance) |
- |
500 |
|
- |
| 6.5(Design for Maintainance) |
- |
500 |
|
- |
| 6.6(Design for Maintainance) |
- |
500 |
|
- |
| 7.0(Rigidity and Stability) |
- |
500 |
|
- |
| 7.1(Rigidity and Stability) |
- |
500 |
|
- |
| 7.2(Rigidity and Stability) |
- |
500 |
|
- |
| 7.3(Rigidity and Stability) |
- |
500 |
|
- |
| 8.1(Workmanship and Finish - Cl. 7 of IS 5116) |
- |
500 |
|
- |
| 8.1(Workmanship and Finish - Cl. 7 of IS 5116) |
- |
0 |
|
- |
| 8.1(Workmanship and Finish - Cl. 7 of IS 5116) |
- |
0 |
|
- |
| 8.1(Workmanship and Finish - Cl. 7 of IS 5116) |
- |
0 |
|
- |
| 8.1(Workmanship and Finish - Cl. 7 of IS 5116) |
- |
0 |
|
- |
| 8.1(Workmanship and Finish - Cl. 7 of IS 5116) |
- |
0 |
|
- |
| 8.1(Workmanship and Finish - Cl. 7 of IS 5116) |
- |
0 |
|
- |
| 8.1(Workmanship and Finish - Cl. 7 of IS 5116) |
- |
0 |
|
- |
| 8.1(Workmanship and Finish - Cl. 7 of IS 5116) |
- |
0 |
|
- |
| 8.1(Workmanship and Finish - Cl. 7 of IS 5116) |
- |
0 |
|
- |
| 8.1(Workmanship and Finish - Cl. 7 of IS 5116) |
- |
0 |
|
- |
| 8.1(Workmanship and Finish - Cl. 7 of IS 5116) |
- |
0 |
|
- |
| 8.2(Workmanship and Finish -) |
- |
0 |
|
- |
| 8.3(Workmanship and Finish -) |
- |
500 |
|
- |
| 9(Gas Taps- Cl. 8 of IS 5116 (Except 8.7 and 8.11.1)) |
- |
1000 |
|
- |
| 9(Gas Taps- Cl. 8 of IS 5116 (Except 8.7 and 8.11.1)) |
- |
0 |
|
- |
| 9(Gas Taps- Cl. 8 of IS 5116 (Except 8.7 and 8.11.1)) |
- |
0 |
|
- |
| 9(Gas Taps- Cl. 8 of IS 5116 (Except 8.7 and 8.11.1)) |
- |
0 |
|
- |
| 9(Gas Taps- Cl. 8 of IS 5116 (Except 8.7 and 8.11.1)) |
- |
0 |
|
- |
| 9(Gas Taps- Cl. 8 of IS 5116 (Except 8.7 and 8.11.1)) |
- |
0 |
|
- |
| 9(Gas Taps- Cl. 8 of IS 5116 (Except 8.7 and 8.11.1)) |
- |
0 |
|
- |
| 9(Gas Taps- Cl. 8 of IS 5116 (Except 8.7 and 8.11.1)) |
- |
0 |
|
- |
| 9(Gas Taps- Cl. 8 of IS 5116 (Except 8.7 and 8.11.1)) |
- |
0 |
|
- |
| 9(Gas Taps- Cl. 8 of IS 5116 (Except 8.7 and 8.11.1)) |
- |
0 |
|
- |
| 9(Gas Taps- Cl. 8 of IS 5116 (Except 8.7 and 8.11.1)) |
- |
0 |
|
- |
| 9(Gas Taps- Cl. 8 of IS 5116 (Except 8.7 and 8.11.1)) |
- |
0 |
|
- |
| 9(Gas Taps- Cl. 8 of IS 5116 (Except 8.7 and 8.11.1)) |
- |
0 |
|
- |
| 9(Gas Taps- Cl. 8 of IS 5116 (Except 8.7 and 8.11.1)) |
- |
0 |
|
- |
| 9(Gas Taps- Cl. 8 of IS 5116 (Except 8.7 and 8.11.1)) |
- |
0 |
|
- |
| 9(Gas Taps- Cl. 8 of IS 5116 (Except 8.7 and 8.11.1)) |
- |
0 |
|
- |
| 9(Gas Taps- Cl. 8 of IS 5116 (Except 8.7 and 8.11.1)) |
- |
0 |
|
- |
| 9(Gas Taps- Cl. 8 of IS 5116 (Except 8.7 and 8.11.1)) |
- |
0 |
|
- |
| 9(Gas Taps- Cl. 8 of IS 5116 (Except 8.7 and 8.11.1)) |
- |
0 |
|
- |
| 9(Gas Taps- Cl. 8 of IS 5116 (Except 8.7 and 8.11.1)) |
- |
0 |
|
- |
| 9(Gas Taps- Cl. 8 of IS 5116 (Except 8.7 and 8.11.1)) |
- |
0 |
|
- |
| 9(Gas Taps- Cl. 8 of IS 5116 (Except 8.7 and 8.11.1)) |
- |
0 |
|
- |
| 9(Gas Taps- Cl. 8 of IS 5116 (Except 8.7 and 8.11.1)) |
- |
0 |
|
- |
| 10(Injector Jets) |
- |
1000 |
|
- |
| 10(Injector Jets) |
- |
0 |
|
- |
| 10(Injector Jets) |
- |
0 |
|
- |
| 10(Injector Jets) |
- |
0 |
|
- |
| 10(Injector Jets) |
- |
0 |
|
- |
| 10(Injector Jets) |
- |
0 |
|
- |
| 11.1(Burners- Cl. 10 of IS 5116) |
- |
500 |
|
- |
| 11.1(Burners- Cl. 10 of IS 5116) |
- |
0 |
|
- |
| 11.1(Burners- Cl. 10 of IS 5116) |
- |
0 |
|
- |
| 11.1(Burners- Cl. 10 of IS 5116) |
- |
0 |
|
- |
| 11.1(Burners- Cl. 10 of IS 5116) |
- |
0 |
|
- |
| 11.2(Burners) |
- |
500 |
|
- |
| 11.3(Burners) |
- |
500 |
|
- |
| 11.4(Burners) |
- |
500 |
|
- |
| 12.1(Burner Pan Support) |
- |
500 |
|
- |
| 12.2(Burner Pan Support) |
- |
0 |
|
- |
| 12.3(Burner Pan Support) |
- |
0 |
|
- |
| 13.1(Gas Soundness Test - Cl. 16 of IS 5116) |
- |
1000 |
|
- |
| 13,2(Gas Soundness Test) |
- |
1000 |
|
- |
| 13.2(Gas Leak Detector) |
- |
1000 |
|
- |
| 14.1(Gas Inlet Connection - Cl. 18 of IS 5116) |
- |
1000 |
|
- |
| 14.1(Gas Inlet Connection - Cl. 18 of IS 5116) |
- |
0 |
|
- |
| 14.1(Gas Inlet Connection - Cl. 18 of IS 5116) |
- |
0 |
|
- |
| 14.1(Gas Inlet Connection - Cl. 18 of IS 5116) |
- |
0 |
|
- |
| 14.1(Gas Inlet Connection - Cl. 18 of IS 5116) |
- |
0 |
|
- |
| 14.1(Gas Inlet Connection - Cl. 18 of IS 5116) |
- |
0 |
|
- |
| 14.1(Gas Inlet Connection - Cl. 18 of IS 5116) |
- |
0 |
|
- |
| 14.1(Gas Inlet Connection - Cl. 18 of IS 5116) |
- |
0 |
|
- |
| 14.1(Gas Inlet Connection - Cl. 18 of IS 5116) |
- |
0 |
|
- |
| 14.1(Gas Inlet Connection - Cl. 18 of IS 5116) |
- |
0 |
|
- |
| 14.1(Gas Inlet Connection - Cl. 18 of IS 5116) |
- |
0 |
|
- |
| 14.1(Gas Inlet Connection - Cl. 18 of IS 5116) |
- |
0 |
|
- |
| 14.1(Gas Inlet Connection - Cl. 18 of IS 5116) |
- |
0 |
|
- |
| 14.2(Gas Inlet Connection) |
- |
500 |
|
- |
| 14.2(Gas Inlet Connection) |
- |
0 |
|
- |
| 14.2(Gas Inlet Connection) |
- |
0 |
|
- |
| 14.2(Gas Inlet Connection) |
- |
0 |
|
- |
| 14.3(Gas Inlet Connection) |
- |
500 |
|
- |
| 14.4(Gas Inlet Connection) |
- |
500 |
|
- |
| 14.5(Gas Inlet Connection - Cl. 17.3 of IS 5116) |
- |
500 |
|
- |
| 14.6(Gas Inlet Connection) |
- |
500 |
|
- |
| 15.0(Strength and Rigidity) |
- |
500 |
|
- |
| 15.0(Strength and Rigidity) |
- |
0 |
|
- |
| 15.0(Strength and Rigidity) |
- |
0 |
|
- |
| 15.0(Strength and Rigidity) |
- |
0 |
|
- |
| 17.0(Gas Consumption Test) |
- |
5000 |
|
- |
| 17.0(Gas Consumption Test) |
- |
0 |
|
- |
| 17.0(Gas Consumption Test) |
- |
0 |
|
- |
| 17.0(Gas Consumption Test) |
- |
0 |
|
- |
| 17.0(Gas Consumption Test) |
- |
0 |
|
- |
| 17.0(Gas Consumption Test) |
- |
0 |
|
- |
| 17.2(Gas Consumption Test - For Gas Stoves) |
- |
5000 |
|
- |
| 17.2 (a)(Gas Consumption Test - For Gas Stoves) |
- |
0 |
|
- |
| 17.2 (b)(Gas Consumption Test - For Gas Stoves) |
- |
0 |
|
- |
| 17.2 (c)(Gas Consumption Test - For Gas Stoves) |
- |
0 |
|
- |
| 17.3(Gas Consumption Test - For Built in Hobs) |
- |
5000 |
|
- |
| 17.3.1(Gas Consumption Test - For Built in Hobs) |
- |
0 |
|
- |
| 17.3.2(Gas Consumption Test - For Built in Hobs) |
- |
0 |
|
- |
| 18.1(Ignition and Flame Travel) |
- |
500 |
|
- |
| 18.1(Ignition and Flame Travel) |
- |
500 |
|
- |
| 18.2(Ignition and Flame Travel) |
- |
0 |
|
- |
| 18.3(Ignition and Flame Travel) |
- |
0 |
|
- |
| 18.4(Ignition and Flame Travel - Cl. 14 of IS 5116) |
- |
0 |
|
- |
| 18.4(Ignition and Flame Travel - Cl. 14 of IS 5116) |
- |
0 |
|
- |
| 18.4(Ignition and Flame Travel - Cl. 14 of IS 5116) |
- |
0 |
|
- |
| 18.4(Ignition and Flame Travel - Cl. 14 of IS 5116) |
- |
0 |
|
- |
| 18.4(Ignition and Flame Travel - Cl. 14 of IS 5116) |
- |
0 |
|
- |
| 18.4(Ignition and Flame Travel - Cl. 14 of IS 5116) |
- |
0 |
|
- |
| 19.1(Flame Stability) |
- |
500 |
|
- |
| 19.1.1(Flame Stability) |
- |
0 |
|
- |
| 19.2(Flame Stability) |
- |
0 |
|
- |
| 19.3(Flame Stability) |
- |
0 |
|
- |
| 20(Noise Control) |
- |
1000 |
|
- |
| 21(Flash Back) |
- |
500 |
|
- |
| 22(Formation of Soot) |
- |
500 |
|
- |
| 23(Resistance to Draught) |
- |
500 |
|
- |
| 24.1(Combustion) |
- |
500 |
|
- |
| 24.1(Combustion) |
- |
0 |
|
- |
| 24.2(Combustion) |
- |
0 |
|
- |
| 25.1(Fire Hazard and Limiting Temperatures) |
- |
500 |
|
- |
| 25.1(Fire Hazard and Limiting Temperatures) |
- |
0 |
|
- |
| 25.1(Fire Hazard and Limiting Temperatures) |
- |
0 |
|
- |
| 25.1(Fire Hazard and Limiting Temperatures) |
- |
0 |
|
- |
| 25.2(Fire Hazard and Limiting Temperatures) |
- |
0 |
|
- |
| 26.1(Thermal Efficiency- Gas Stoves) |
- |
5000 |
|
- |
| 26.1(Thermal Efficiency- Gas Stoves) |
- |
0 |
|
- |
| 26.1(Thermal Efficiency- Gas Stoves) |
- |
0 |
|
- |
| 26.1(Thermal Efficiency- Gas Stoves) |
- |
0 |
|
- |
| 26.1(Thermal Efficiency- Gas Stoves) |
- |
0 |
|
- |
| 26.2(Thermal Efficiency- For Built in Hobs) |
- |
5000 |
|
- |
| 26.2(Thermal Efficiency- For Built in Hobs) |
- |
0 |
|
- |
| 26.2(Thermal Efficiency- For Built in Hobs) |
- |
0 |
|
- |
| 26.2(Thermal Efficiency- For Built in Hobs) |
- |
0 |
|
- |
| 26.2(Thermal Efficiency- For Built in Hobs) |
- |
0 |
|
- |
| 5.1.1(Materials - IS 5116) |
- |
1000 |
|
- |
|
15 Jun, 2029 |
- Included w.e.f. 17.03.2026 |
| 1319 |
Urja Metallurgical Services LLP
| 7194806
| IS 1364 : Part 2 (2023) |
Hexagon head bolts screws and nuts of product grades A and B Part 2 Hexagon head screws (Size range M1.6 to M64 ) (Sixth revision of IS 1364 (Part 2)) |
All Grade / Type / Size / Designation / Class |
10300 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl-4(Dimensions) |
- |
0 |
|
- |
| Cl-5, Table-5(General requirements) |
- |
0 |
|
- |
| Cl-5, Table-5(Thread-Tolerance class) |
- |
0 |
|
- |
| Cl-5, Table-5(Mechanical properties-Steel) |
- |
0 |
|
- |
| Cl-5, Table-5(Mechanical properties-Stainless steel) |
- |
0 |
|
- |
| Cl-5, Table-5(Tolerances- Product grade) |
- |
0 |
|
- |
| Cl-5, Table-5(Surface condition -Electroplated coatings) |
- |
0 |
|
- |
| Cl-5, Table-5(Surface condition- Non-electrolytically applied zinc flake) |
- |
0 |
|
- |
| Cl-5, Table-5(Surface condition - Hot dip galvanized coatings) |
- |
0 |
|
- |
| Cl-5, Table-5("Surface integrity
-Limits for surface discontinuities") |
- |
0 |
|
- |
| Cl-6(Marking) |
- |
0 |
|
- |
|
23 Dec, 2028 |
- Included w.e.f 27.01.2026 |
| 1320 |
IDMA LABORATORIES LIMITED, PANCHKULA
| 9123236
| IS 11019 (2025) |
Carbofuran technical - Specification (first revision) |
- |
6000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 3.1("Description
( IS 11019: 2025 )") |
- |
500 |
|
- |
| 3.2, Table 1 (i)(Carbofuran Content (IS 9360 : 2024)) |
- |
3000 |
|
- |
| 3.2, Table 1 (ii)(Moisture (IS 6940 : 2025) |
- |
1500 |
|
- |
| 3.2, Table 1 (iii)(Alkalinity (as NaOH) (IS 6940 : 2025)) |
- |
1000 |
|
- |
|
31 Dec, 2026 |
- included w.e.f 17.03.2026 |