1291 |
DELHI TEST HOUSE, Azadhpur
| IS 4984 (2016) |
Polyethylene pipes for water supply - Specification (Fifth Revision) |
- |
-
|
35400 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
6.2(Colour) |
- |
250 |
|
For DN 10mm - 400mm= Rs. 36500/- For DN 401mm - 630mm= Rs. 42500/ |
6.2.1(6.1.1 Identification Stripes) |
- |
250 |
|
For DN 10mm - 400mm= Rs. 36500/- For DN 401mm - 630mm= Rs. 42500/ |
7.2(Length) |
- |
250 |
|
For DN 10mm - 400mm= Rs. 36500/- For DN 401mm - 630mm= Rs. 42500/ |
7.4 table -3 & 4(6.1 Dimensions) |
- |
500 |
|
For DN 10mm - 400mm= Rs. 36500/- For DN 401mm - 630mm= Rs. 42500/ |
8,/8.1/8.1.1 table-5(PERFORMANCE REQUIREMENTS / Hydraulic Characteristics/ Internal Pressure Creep Rupture Test of Pipe) |
- |
15000 |
|
For DN 10mm - 400mm= Rs. 36500/- For DN 401mm - 630mm= Rs. 42500/ |
8.2(Longitudinal Reversion Test) |
- |
1500 |
|
For DN 10mm - 400mm= Rs. 36500/- For DN 401mm - 630mm= Rs. 42500/ |
8.3(Carbon black) |
- |
2500 |
|
For DN 10mm - 400mm= Rs. 36500/- For DN 401mm - 630mm= Rs. 42500/ |
8.4( Melt Flow Rate) |
- |
1500 |
|
For DN 10mm - 400mm= Rs. 36500/- For DN 401mm - 630mm= Rs. 42500/ |
8.5 (Oxidation Induction Time) |
- |
4000 |
|
For DN 10mm - 400mm= Rs. 36500/- For DN 401mm - 630mm= Rs. 42500/ |
8.6(Overall migration) |
- |
3500 |
|
For DN 10mm - 400mm= Rs. 36500/- For DN 401mm - 630mm= Rs. 42500/ |
8.7(Density) |
- |
1000 |
|
For DN 10mm - 400mm= Rs. 36500/- For DN 401mm - 630mm= Rs. 42500/ |
8.8(Tensile Strength for Butt-fusion) |
- |
1500 |
|
For DN 10mm - 400mm= Rs. 36500/- For DN 401mm - 630mm= Rs. 42500/ |
8.9 table-6(Elongation at Break) |
- |
1000 |
|
For DN 10mm - 400mm= Rs. 36500/- For DN 401mm - 630mm= Rs. 42500/ |
8.10(Slow Crack Growth Rate) |
- |
3500 |
|
For DN 10mm - 400mm= Rs. 36500/- For DN 401mm - 630mm= Rs. 42500/ |
5.2(Polyethylene Resin) |
- |
8000 |
|
For DN 10mm - 400mm= Rs. 36500/- For DN 401mm - 630mm= Rs. 42500/ |
5.3(c)(Carbon Black Master Batch) |
- |
1500 |
|
For DN 10mm - 400mm= Rs. 36500/- For DN 401mm - 630mm= Rs. 42500/ |
5.3(d)(Carbon Black Master Batch) |
- |
1500 |
|
For DN 10mm - 400mm= Rs. 36500/- For DN 401mm - 630mm= Rs. 42500/ |
5.4(Anti oxydent) |
- |
1000 |
|
For DN 10mm - 400mm= Rs. 36500/- For DN 401mm - 630mm= Rs. 42500/ |
5.3(b)(Carbon Black Master Batch) |
- |
2000 |
|
For DN 10mm - 400mm= Rs. 36500/- For DN 401mm - 630mm= Rs. 42500/ |
5.3(e)(Carbon Black Master Batch) |
- |
1000 |
|
For DN 10mm - 400mm= Rs. 36500/- For DN 401mm - 630mm= Rs. 42500/ |
8.1.2 table -5(Internal Pressure Creep Rupture Test of Pipe Joints) |
- |
1000 |
|
For DN 10mm - 400mm= Rs. 36500/- For DN 401mm - 630mm= Rs. 42500/ |
7.4.1.2(Ovality) |
- |
250 |
|
For DN 10mm - 400mm= Rs. 36500/- For DN 401mm - 630mm= Rs. 42500/ |
7.4 table -3 & 4(6.1 Dimensions) |
- |
250 |
|
For DN 10mm - 400mm= Rs. 36500/- For DN 401mm - 630mm= Rs. 42500/ |
5.3(b)(Carbon Black Master Batch) |
- |
1500 |
|
For DN 10mm - 400mm= Rs. 36500/- For DN 401mm - 630mm= Rs. 42500/ |
5.3 (a)(Carbon Black Master Batch) |
- |
1500 |
|
For DN 10mm - 400mm= Rs. 36500/- For DN 401mm - 630mm= Rs. 42500/ |
5.2(Density) |
- |
1000 |
|
For DN 10mm - 400mm= Rs. 36500/- For DN 401mm - 630mm= Rs. 42500/ |
5.2(Volatile matter Content) |
- |
1000 |
|
For DN 10mm - 400mm= Rs. 36500/- For DN 401mm - 630mm= Rs. 42500/ |
5.3(Toluene Extract) |
- |
1500 |
|
For DN 10mm - 400mm= Rs. 36500/- For DN 401mm - 630mm= Rs. 42500/ |
Clause 7.1(Visual Apperance) |
- |
250 |
|
For DN 10mm - 400mm= Rs. 36500/- For DN 401mm - 630mm= Rs. 42500/ |
Clause 8.3(Carbon Black content) |
- |
1500 |
|
For DN 10mm - 400mm= Rs. 36500/- For DN 401mm - 630mm= Rs. 42500/ |
Clause 8.3(Carbon Black Dispersion) |
- |
1500 |
|
For DN 10mm - 400mm= Rs. 36500/- For DN 401mm - 630mm= Rs. 42500/ |
Clause 8.6(Overall migration (stimulate)) |
- |
1000 |
|
For DN 10mm - 400mm= Rs. 36500/- For DN 401mm - 630mm= Rs. 42500/ |
Clause 8.6(Overall migration (surface of material)) |
- |
1000 |
|
For DN 10mm - 400mm= Rs. 36500/- For DN 401mm - 630mm= Rs. 42500/ |
7.1(Visual Appearance) |
- |
250 |
|
For DN 10mm - 400mm= Rs. 36500/- For DN 401mm - 630mm= Rs. 42500/ |
Table-2 (iii, iv)(Thermal Stability (Oxidation Induction Time), Volatile Matter) |
- |
1000 |
|
For DN 10mm - 400mm= Rs. 36500/- For DN 401mm - 630mm= Rs. 42500/ |
Cl. 8.3(Carbon Black Content) |
- |
1500 |
|
For DN 10mm - 400mm= Rs. 36500/- For DN 401mm - 630mm= Rs. 42500/ |
Cl. 8.3(Carbon Black Dispersion) |
- |
1500 |
|
For DN 10mm - 400mm= Rs. 36500/- For DN 401mm - 630mm= Rs. 42500/ |
5.2,T2(Melt Flow rate(Temperature - 190oC,Mass 5kg)-IS 2530-1963) |
- |
2500 |
|
For DN 10mm - 400mm= Rs. 36500/- For DN 401mm - 630mm= Rs. 42500/ |
8.7(Density-IS 7328:2020) |
- |
1000 |
|
For DN 10mm - 400mm= Rs. 36500/- For DN 401mm - 630mm= Rs. 42500/ |
8.7(Corrected Density- IS 7328:2020) |
- |
1000 |
|
For DN 10mm - 400mm= Rs. 36500/- For DN 401mm - 630mm= Rs. 42500/ |
8.9,T6("Tensile - IS 4984-2016
(Annexure-H)") |
- |
1000 |
|
For DN 10mm - 400mm= Rs. 36500/- For DN 401mm - 630mm= Rs. 42500/ |
8.9,T6("Elongation -IS 4984-2016
(Annexure-H)") |
- |
1000 |
|
For DN 10mm - 400mm= Rs. 36500/- For DN 401mm - 630mm= Rs. 42500/ |
Cl 8.3(Carbon Black Content) |
- |
1500 |
|
For DN 10mm - 400mm= Rs. 36500/- For DN 401mm - 630mm= Rs. 42500/ |
Cl 8.3(Carbon Black Dispersion) |
- |
1500 |
|
For DN 10mm - 400mm= Rs. 36500/- For DN 401mm - 630mm= Rs. 42500/- |
|
Complete
|
|
- |
- - |
1292 |
DELHI TEST HOUSE, Azadhpur
| IS 15965 (2012) |
Pre - Painted aluminium zinc alloy metallic coated steel strip and sheet (Plain) |
- |
-
|
25500 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
Cl 8.3.1(Adhesion ) |
- |
2000 |
|
Rs.25500/-, FOR - Corrosive resistance test @15/- per hour extra, Humidity resistance test @Rs.15/- per hour extra |
Cl 8.3.2(Impact Resistance) |
- |
1500 |
|
Rs.25500/-, FOR - Corrosive resistance test @15/- per hour extra, Humidity resistance test @Rs.15/- per hour extra |
Cl 8.4(Load Resistance) |
- |
1500 |
|
Rs.25500/-, FOR - Corrosive resistance test @15/- per hour extra, Humidity resistance test @Rs.15/- per hour extra |
Cl 8.5(Scratch Resistance) |
- |
1500 |
|
Rs.25500/-, FOR - Corrosive resistance test @15/- per hour extra, Humidity resistance test @Rs.15/- per hour extra |
Cl 8.7(Dry Film Thickness) |
- |
500 |
|
Rs.25500/-, FOR - Corrosive resistance test @15/- per hour extra, Humidity resistance test @Rs.15/- per hour extra |
Cl 9.1(Workmanship) |
- |
500 |
|
Rs.25500/-, FOR - Corrosive resistance test @15/- per hour extra, Humidity resistance test @Rs.15/- per hour extra |
Cl 10.1(Corrosion Test) |
- |
2000 |
|
Rs.25500/-, FOR - Corrosive resistance test @15/- per hour extra, Humidity resistance test @Rs.15/- per hour extra |
Cl 10.2(Humidity Test) |
- |
4500 |
|
Rs.25500/-, FOR - Corrosive resistance test @15/- per hour extra, Humidity resistance test @Rs.15/- per hour extra |
Cl 11(Length, Width & Thickness) |
- |
1500 |
|
Rs.25500/-, FOR - Corrosive resistance test @15/- per hour extra, Humidity resistance test @Rs.15/- per hour extra |
Cl 12(Camber, Deviation From Squareness (Out-of- Square) & Deviation From Flatness) |
- |
1500 |
|
Rs.25500/-, FOR - Corrosive resistance test @15/- per hour extra, Humidity resistance test @Rs.15/- per hour extra |
Cl 8.3.1(Adhesion ) |
- |
1000 |
|
Rs.25500/-, FOR - Corrosive resistance test @15/- per hour extra, Humidity resistance test @Rs.15/- per hour extra |
Cl 8.3.2(Impact Resistance) |
- |
1000 |
|
Rs.25500/-, FOR - Corrosive resistance test @15/- per hour extra, Humidity resistance test @Rs.15/- per hour extra |
Cl 10.2(Humidity Test) |
- |
1000 |
|
Rs.25500/-, FOR - Corrosive resistance test @15/- per hour extra, Humidity resistance test @Rs.15/- per hour extra |
Cl 11(Length, Width & Thickness) |
- |
1500 |
|
Rs.25500/-, FOR - Corrosive resistance test @15/- per hour extra, Humidity resistance test @Rs.15/- per hour extra |
Cl 12(Camber, Deviation From Squareness (Out-of- Square) & Deviation From Flatness) |
- |
1500 |
|
Rs.25500/-, FOR - Corrosive resistance test @15/- per hour extra, Humidity resistance test @Rs.15/- per hour extra |
8.6(Solvent Resistance test) |
- |
1000 |
|
Rs.25500/-, FOR - Corrosive resistance test @15/- per hour extra, Humidity resistance test @Rs.15/- per hour extra |
9.2(colour) |
- |
500 |
|
Rs.25500/-, FOR - Corrosive resistance test @15/- per hour extra, Humidity resistance test @Rs.15/- per hour extra |
9.3(Gloss (60 Deg)) |
- |
1000 |
|
Rs.25500/-, FOR - Corrosive resistance test @15/- per hour extra, Humidity resistance test @Rs.15/- per hour extra |
Cl 10.1(Corrosion Test) |
- |
15 |
|
Rs.25500/-, FOR - Corrosive resistance test @15/- per hour extra, Humidity resistance test @Rs.15/- per hour extra |
10.1(IS 9844) |
- |
15 |
|
Rs.25500/-, FOR - Corrosive resistance test @15/- per hour extra, Humidity resistance test @Rs.15/- per hour extra |
7 & 7.3(ISO 2808) |
- |
2000 |
|
Rs.25500/-, FOR - Corrosive resistance test @15/- per hour extra, Humidity resistance test @Rs.15/- per hour extra |
11.0(Thickness) |
- |
500 |
|
Rs.25500/-, FOR - Corrosive resistance test @15/- per hour extra, Humidity resistance test @Rs.15/- per hour extra |
|
Complete
|
|
- |
- - |
1293 |
DELHI TEST HOUSE, Azadhpur
| IS 1161 (2014) |
Steel tubes for structural purposes - Specification (Fifth Revision) |
- |
-
|
12000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
Cl 6(Outer Diameter, Thickness & Mass) |
- |
250 |
|
For BIS Samples: 1.5 times of BIS testing charges |
Cl 7(Workmanship) |
- |
200 |
|
For BIS Samples: 1.5 times of BIS testing charges |
Cl 11(Tensile Test, Flattening Test & Cold Bend Test) |
- |
3000 |
|
For BIS Samples: 1.5 times of BIS testing charges |
Cl 6(Outer Diameter, Thickness & Mass) |
- |
1500 |
|
- |
8 AND AS PER IS 4736(UNIFORMITY OF ZINC COATING) |
- |
1500 |
|
- |
8 AND AS PER IS 4736(MASS OF ZINC COATING) |
- |
1500 |
|
- |
5 AND AS PER IS 10748(CARBON EQUIVALENT) |
- |
500 |
|
- |
5 AND AS PER IS 10748(CARBON) |
- |
500 |
|
- |
Clause - 5.1, Table-3( ALUMINIUM) |
- |
500 |
|
- |
Clause - 5.1, Table-3(SILICON) |
- |
500 |
|
- |
Clause - 5.1, Table-3(NITROGEN) |
- |
2000 |
|
- |
Clause - 5.1, Table-3(MANGANESE) |
- |
500 |
|
- |
Clause - 5.1, Table-3(SULPHUR) |
- |
500 |
|
- |
Clause - 5.1, Table-3( CARBON) |
- |
500 |
|
- |
9(Straightness) |
- |
500 |
|
- |
10(Lengths) |
- |
500 |
|
- |
Cl 11.3.1(Flattening test (over 50 mm NB)) |
- |
500 |
|
- |
Cl. 11.2 Table 2(Elongation) |
- |
1000 |
|
- |
Cl 11.3.1(Cold bend test (upto & including 50 mm NB)) |
- |
1000 |
|
- |
Cl. 11.2 Table 2(Yield strength) |
- |
1000 |
|
- |
Cl. 6 , 6.2 Table 1(Weight) |
- |
500 |
|
- |
Cl. 6 , 6.2 Table 1(Thickness) |
- |
500 |
|
- |
Clause 11.2, Table -2(Elongation) |
- |
1000 |
|
- |
Clause 11.2, Table -2(Yield Strength) |
- |
1000 |
|
- |
Cl 13(Workmanship) |
- |
200 |
|
- |
Cl 11(Tensile Test, Flattening Test & Cold Bend Test) |
- |
3000 |
|
- |
Cl 6(Outer Diameter, Thickness & Mass) |
- |
1500 |
|
- |
3.1 & 6.1, 6.1.1 & 6.1.3 , Table 1(Outer Diameter - SOP MT-23) |
- |
500 |
|
- |
3.1 & 6.1, 6.1.1 & 6.1.3 , Table 1(Thickness - SOP MT-23) |
- |
500 |
|
- |
3.1 & 6.1, 6.1.1 & 6.1.3 , Table 1(Mass - SOP MT-23) |
- |
500 |
|
- |
3.1 & 6.1, 6.1.1 & 6.1.3 , Table 1(Area of Cross Section - SOP MT-23) |
- |
500 |
|
- |
8.0(Mass of Zinc coating - IS:6745) |
- |
1500 |
|
- |
8.0(Uniformity of galvanized coating - IS 4736) |
- |
1500 |
|
- |
13.0(Oiling and Painting - Visual) |
- |
500 |
|
- |
|
Complete
|
|
- |
- - |
1294 |
DELHI TEST HOUSE, Azadhpur
| IS 10124 : Part 1 (2009) |
Fabricated PVC-U Fittings for Potable Water Supplies - Specification Part 1 General Requirements (Second Revision) |
- |
-
|
7500 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
3(Material) |
- |
250 |
|
NA |
4(Size of fitting) |
- |
250 |
|
NA |
5.1 Table-1 Fig.1(Dimension of Socket length) |
- |
250 |
|
NA |
5.1.2 Table-1(Dimensions of mean inside diameter at mid-point of socket depth) |
- |
250 |
|
NA |
5.1.3 (Out of Roundness Tolerance of Socket Inside Diameter) |
- |
250 |
|
NA |
5.2 Table-2 Fig.2(Dimensions of socket for elastomeric sealing ring) |
- |
250 |
|
NA |
6.1(Opacity test in accordance with IS 12235 (Part 3)) |
- |
1000 |
|
NA |
6.2(Short Term Hydraulic Test in accordance with Annex A) |
- |
2000 |
|
NA |
8(Marking) |
- |
250 |
|
NA |
6.3(Effect on water test) |
- |
5500 |
|
NA |
|
Complete
|
|
- |
- - |
1295 |
SHRI BAJRANG TESTING LABS
| IS 15658 (2021) |
Concrete Paving Blocks - Specification ( First Revision ) |
All |
-
|
19500 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
Clause 7.3 & 9.1.4, Table 3, SI No. (vi)(Freeze Thaw durability (Visual Rating of specimen after 50 cycles) |
- |
1500 |
|
- |
Clause 7.3 & 9.1.4, Table 3, SI No. (vi)(Freeze Thaw durability (Visual Rating of specimen after 25 cycles) |
- |
1500 |
|
- |
Clause 7.3 & 9.1.4, Table 3, SI No. (vi)(Freeze Thaw durability (Visual Rating of specimen after 10 cycles) |
- |
1000 |
|
- |
Clause 7.3 & 9.1.4, Table 3, SI No. (vi)(Freeze Thaw durability (Cumulative Weight losses of specimen after 10, 25 & 50 cycles) |
- |
1500 |
|
- |
Clause 7.3 & 9.1.4, Table 3, SI No. (vi)(Freeze Thaw durability (Weight losses of specimen after 50 cycles) |
- |
1500 |
|
- |
Clause 7.3 & 9.1.4, Table 3, SI No. (vi)(Freeze Thaw durability (Weight losses of specimen after 25 cycles) |
- |
1000 |
|
- |
Clause 7.3 & 9.1.4, Table 3, SI No. (vi)(Freeze Thaw durability (Weight losses of specimen after 10 cycles) |
- |
1500 |
|
- |
Clause 7.3, Annex G(Average Breaking Load) |
- |
1000 |
|
- |
Clause 7.3, Annex G(Individual Breaking Load) |
- |
1000 |
|
- |
Clause 7.3, Annex F(Average Failure Load per unit Length) |
- |
600 |
|
- |
Clause 7.3, Annex F(Individual Failure Load per unit Length) |
- |
0 |
|
- |
Clause 7.3 & 9.1.4, Table 3, SI No. (v) b)(Average Flexural strength ) |
- |
3000 |
|
- |
Clause 7.3 & 9.1.4, Table 3, SI No. (v) a)(Indivdual Flexural strength ) |
- |
0 |
|
- |
Clause 7.3 & 9.1.4, Table 3, SI No. (iv) b)(Average Tensile splitting strength ) |
- |
2500 |
|
- |
Clause 7.3 & 9.1.4, Table 3, SI No. (iv) a)(Indivdual Tensile splitting strength ) |
- |
2500 |
|
- |
Clause 7.3 & 9.1.4, Table 3, SI No. (iii) b) ii)(Wet Abrasion resistance (Average of three test specimens)) |
- |
2500 |
|
- |
Clause 7.3 & 9.1.4, Table 3, SI No. (iii) b) i)( Indivdual Wet Abrasion Resistance ) |
- |
0 |
|
- |
Clause 7.3 & 9.1.4, Table 3, SI No. (iii) a) ii)(Dry Abrasion resistance (Average of three test specimens)) |
- |
2500 |
|
- |
Clause 7.3 & 9.1.4, Table 3, SI No. (iii) a) i)( Indivdual Dry Abrasion Resistance ) |
- |
0 |
|
- |
Clause 7.3 & 9.1.4, Table 3, SI No. (ii) b)(Compressive strength (Average of eight test specimens)) |
- |
4500 |
|
- |
Clause 7.3 & 9.1.4, Table 3, SI No. (ii) a)( Indivdual Compressive strength) |
- |
0 |
|
- |
Clause 7.3 & 9.1.4, Table 3, SI No. (i) b)(Water absorption (Average of three test specimens)) |
- |
2500 |
|
- |
Clause 7.3 & 9.1.4, Table 3, SI No. (i) a)( Indivdual Water absorption) |
- |
0 |
|
- |
Clause 7.2 & 9.1.3, Table 2, SI No. (ix)(Deviation from squareness) |
- |
3000 |
|
- |
Clause 7.2 & 9.1.3, Table 2, SI No. (viii)(Indivdual Ratio of wearing face area and Plan area (Asw/Asp)) |
- |
500 |
|
- |
Clause 7.2 & 9.1.3, Table 2, SI No. (viii)(Ratio of wearing face area and Plan area (Asw/Asp)) |
- |
0 |
|
- |
Clause 7.2 & 9.1.3, Table 2, SI No. (vii)(Indivdual Plan Area (Asp)) |
- |
300 |
|
- |
Clause 7.2 & 9.1.3, Table 2, SI No. (vii)(Plan Area (Asp)) |
- |
300 |
|
- |
Clause 7.2 & 9.1.3, Table 2, SI No. (vi)(Indivdual Thickness of wearing Layer) |
- |
300 |
|
- |
Clause 7.2 & 9.1.3, Table 2, SI No. (vi)(Thickness of wearing Layer) |
- |
300 |
|
- |
Clause 7.2 & 9.1.3, Table 2, SI No. (v)(Indivdual Arris/chamfer, Depth) |
- |
300 |
|
- |
Clause 7.2 & 9.1.3, Table 2, SI No. (v)(Arris/chamfer, Depth) |
- |
300 |
|
- |
Clause 7.2 & 9.1.3, Table 2, SI No. (v)(Indivdual Arris/chamfer, Width) |
- |
300 |
|
- |
Clause 7.2 & 9.1.3, Table 2, SI No. (v)(Arris/chamfer, Width) |
- |
200 |
|
- |
Clause 7.2, Table No. 2, SI No. (iv)
(Indivdual Aspect Ratio, L/Th) |
- |
200 |
|
- |
Clause 7.2, Table No. 2, SI No. (iv)
(Aspect Ratio, L/Th) |
- |
200 |
|
- |
Clause 7.2, Table No. 2, SI No. (iii)
(Indivdual Thickness, Th) |
- |
200 |
|
- |
Clause 7.2, Table No. 2, SI No. (iii)
(Thickness, Th) |
- |
200 |
|
- |
Clause 7.2, Table No. 2, SI No. (ii)
(Indivdual Length, L) |
- |
200 |
|
- |
Clause 7.2, Table No. 2, SI No. (ii)
(Length, L) |
- |
200 |
|
- |
Clause 7.2, Table No. 2, SI No. (i)
(Indivdual Width, W) |
- |
200 |
|
- |
Clause 7.2, Table No. 2, SI No. (i)
(Width, W) |
- |
200 |
|
- |
Clause 6.3
(Bonding and Delamination between the layers of paver blocks) |
- |
200 |
|
- |
Clause 7.1.3
(Colour and Texture) |
- |
500 |
|
- |
Clauses 7.1.2 & 9.1.2
(Visual Inspection) |
- |
700 |
|
- |
Clause 7.1.1
(General Quality) |
- |
500 |
|
- |
7.2- TABLE-2- (i) IS-15658 (Annex-B)(Individual Width - Lower) |
- |
500 |
|
- |
7.2- TABLE-2- (i) IS-15658 (Annex-B)(Average Width -Lower) |
- |
0 |
|
- |
7.2- TABLE-2- (i) IS-15658 (Annex-B)(Individual Width - Higher) |
- |
500 |
|
- |
7.2- TABLE-2- (i) IS-15658 (Annex-B)(Average Width -Higher) |
- |
0 |
|
- |
Clause 3.20(Spacer nibs) |
- |
400 |
|
- |
10(Marking) |
- |
500 |
|
- |
cl.5(Cement) |
- |
0 |
|
- |
5.2(Mineral Admixture) |
- |
0 |
|
- |
5.3(Chemical Admixtures) |
- |
0 |
|
- |
5.4(Coarse and Fine
Aggregates) |
- |
0 |
|
- |
5.5(Pigments) |
- |
0 |
|
- |
5.6(Water) |
- |
0 |
|
- |
Clause 7.3 & 9.1.4, Table 3, SI No. (vi)(Freeze Thaw durability (Visual Rating of specimen after 50 cycles) |
- |
0 |
|
- |
Clause 7.3 & 9.1.4, Table 3, SI No. (vi)(Freeze Thaw durability (Visual Rating of specimen after 25 cycles) |
- |
0 |
|
- |
Clause 7.3 & 9.1.4, Table 3, SI No. (vi)(Freeze Thaw durability (Visual Rating of specimen after 10 cycles) |
- |
0 |
|
- |
Clause 7.3 & 9.1.4, Table 3, SI No. (vi)(Freeze Thaw durability (Cumulative Weight losses of specimen after 10, 25 & 50 cycles) |
- |
0 |
|
- |
Clause 7.3 & 9.1.4, Table 3, SI No. (vi)(Freeze Thaw durability (Weight losses of specimen after 50 cycles) |
- |
0 |
|
- |
Clause 7.3 & 9.1.4, Table 3, SI No. (vi)(Freeze Thaw durability (Weight losses of specimen after 25 cycles) |
- |
0 |
|
- |
Clause 7.3 & 9.1.4, Table 3, SI No. (vi)(Freeze Thaw durability (Weight losses of specimen after 10 cycles) |
- |
0 |
|
- |
Clause 7.3, Annex G(Average Breaking Load) |
- |
0 |
|
- |
Clause 7.3, Annex G(Individual Breaking Load) |
- |
0 |
|
- |
Clause 7.3, Annex F(Average Failure Load per unit Length) |
- |
0 |
|
- |
Clause 7.3, Annex F(Individual Failure Load per unit Length) |
- |
0 |
|
- |
Clause 7.3 & 9.1.4, Table 3, SI No. (v) b)(Average Flexural strength ) |
- |
0 |
|
- |
Clause 7.3 & 9.1.4, Table 3, SI No. (v) a)(Indivdual Flexural strength ) |
- |
0 |
|
- |
Clause 7.3 & 9.1.4, Table 3, SI No. (iv) b)(Average Tensile splitting strength ) |
- |
0 |
|
- |
Clause 7.3 & 9.1.4, Table 3, SI No. (iv) a)(Indivdual Tensile splitting strength ) |
- |
0 |
|
- |
Clause 7.3 & 9.1.4, Table 3, SI No. (iii) b) ii)(Wet Abrasion resistance (Average of three test specimens)) |
- |
0 |
|
- |
Clause 7.3 & 9.1.4, Table 3, SI No. (iii) b) i)( Indivdual Wet Abrasion Resistance ) |
- |
0 |
|
- |
Clause 7.3 & 9.1.4, Table 3, SI No. (iii) a) ii)(Dry Abrasion resistance (Average of three test specimens)) |
- |
0 |
|
- |
Clause 7.3 & 9.1.4, Table 3, SI No. (iii) a) i)( Indivdual Dry Abrasion Resistance ) |
- |
0 |
|
- |
Clause 7.3 & 9.1.4, Table 3, SI No. (ii) b)(Compressive strength (Average of eight test specimens)) |
- |
0 |
|
- |
Clause 7.3 & 9.1.4, Table 3, SI No. (ii) a)( Indivdual Compressive strength) |
- |
0 |
|
- |
Clause 7.3 & 9.1.4, Table 3, SI No. (i) b)(Water absorption (Average of three test specimens)) |
- |
0 |
|
- |
Clause 7.3 & 9.1.4, Table 3, SI No. (i) a)( Indivdual Water absorption) |
- |
0 |
|
- |
Clause 7.2 & 9.1.3, Table 2, SI No. (ix)(Deviation from squareness) |
- |
0 |
|
- |
Clause 7.2 & 9.1.3, Table 2, SI No. (viii)(Indivdual Ratio of wearing face area and Plan area (Asw/Asp)) |
- |
0 |
|
- |
Clause 7.2 & 9.1.3, Table 2, SI No. (viii)(Ratio of wearing face area and Plan area (Asw/Asp)) |
- |
0 |
|
- |
Clause 7.2 & 9.1.3, Table 2, SI No. (vii)(Indivdual Plan Area (Asp)) |
- |
0 |
|
- |
Clause 7.2 & 9.1.3, Table 2, SI No. (vii)(Plan Area (Asp)) |
- |
0 |
|
- |
Clause 7.2 & 9.1.3, Table 2, SI No. (vi)(Indivdual Thickness of wearing Layer) |
- |
0 |
|
- |
Clause 7.2 & 9.1.3, Table 2, SI No. (vi)(Thickness of wearing Layer) |
- |
0 |
|
- |
Clause 7.2 & 9.1.3, Table 2, SI No. (v)(Indivdual Arris/chamfer, Depth) |
- |
0 |
|
- |
Clause 7.2 & 9.1.3, Table 2, SI No. (v)(Arris/chamfer, Depth) |
- |
0 |
|
- |
Clause 7.2 & 9.1.3, Table 2, SI No. (v)(Indivdual Arris/chamfer, Width) |
- |
0 |
|
- |
Clause 7.2 & 9.1.3, Table 2, SI No. (v)(Arris/chamfer, Width) |
- |
0 |
|
- |
Clause 7.2, Table No. 2, SI No. (iv)
(Indivdual Aspect Ratio, L/Th) |
- |
0 |
|
- |
Clause 7.2, Table No. 2, SI No. (iv)
(Aspect Ratio, L/Th) |
- |
0 |
|
- |
Clause 7.2, Table No. 2, SI No. (iii)
(Indivdual Thickness, Th) |
- |
0 |
|
- |
Clause 7.2, Table No. 2, SI No. (iii)
(Thickness, Th) |
- |
0 |
|
- |
Clause 7.2, Table No. 2, SI No. (ii)
(Indivdual Length, L) |
- |
0 |
|
- |
Clause 7.2, Table No. 2, SI No. (ii)
(Length, L) |
- |
0 |
|
- |
Clause 7.2, Table No. 2, SI No. (i)
(Indivdual Width, W) |
- |
0 |
|
- |
Clause 7.2, Table No. 2, SI No. (i)
(Width, W) |
- |
0 |
|
- |
Clause 6.3
(Bonding and Delamination between the layers of paver blocks) |
- |
0 |
|
- |
Clause 7.1.3
(Colour and Texture) |
- |
0 |
|
- |
Clauses 7.1.2 & 9.1.2
(Visual Inspection) |
- |
0 |
|
- |
Clause 7.1.1
(General Quality) |
- |
0 |
|
- |
7.2- TABLE-2- (i) IS-15658 (Annex-B)(Individual Width - Lower) |
- |
0 |
|
- |
7.2- TABLE-2- (i) IS-15658 (Annex-B)(Average Width -Lower) |
- |
0 |
|
- |
7.2- TABLE-2- (i) IS-15658 (Annex-B)(Individual Width - Higher) |
- |
0 |
|
- |
7.2- TABLE-2- (i) IS-15658 (Annex-B)(Average Width -Higher) |
- |
0 |
|
- |
Clause 3.20(Spacer nibs) |
- |
0 |
|
- |
10(Marking) |
- |
0 |
|
- |
cl.5(Cement) |
- |
0 |
|
- |
5.2(Mineral Admixture) |
- |
0 |
|
- |
5.3(Chemical Admixtures) |
- |
0 |
|
- |
5.4(Coarse and Fine
Aggregates) |
- |
0 |
|
- |
5.5(Pigments) |
- |
0 |
|
- |
5.6(Water) |
- |
0 |
|
- |
Clause 7.3 & 9.1.4, Table 3, SI No. (vi)(Freeze Thaw durability (Visual Rating of specimen after 50 cycles) |
- |
0 |
|
- |
Clause 7.3 & 9.1.4, Table 3, SI No. (vi)(Freeze Thaw durability (Visual Rating of specimen after 25 cycles) |
- |
0 |
|
- |
Clause 7.3 & 9.1.4, Table 3, SI No. (vi)(Freeze Thaw durability (Visual Rating of specimen after 10 cycles) |
- |
0 |
|
- |
Clause 7.3 & 9.1.4, Table 3, SI No. (vi)(Freeze Thaw durability (Cumulative Weight losses of specimen after 10, 25 & 50 cycles) |
- |
0 |
|
- |
Clause 7.3 & 9.1.4, Table 3, SI No. (vi)(Freeze Thaw durability (Weight losses of specimen after 50 cycles) |
- |
0 |
|
- |
Clause 7.3 & 9.1.4, Table 3, SI No. (vi)(Freeze Thaw durability (Weight losses of specimen after 25 cycles) |
- |
0 |
|
- |
Clause 7.3 & 9.1.4, Table 3, SI No. (vi)(Freeze Thaw durability (Weight losses of specimen after 10 cycles) |
- |
0 |
|
- |
Clause 7.3, Annex G(Average Breaking Load) |
- |
0 |
|
- |
Clause 7.3, Annex G(Individual Breaking Load) |
- |
0 |
|
- |
Clause 7.3, Annex F(Average Failure Load per unit Length) |
- |
0 |
|
- |
Clause 7.3, Annex F(Individual Failure Load per unit Length) |
- |
0 |
|
- |
Clause 7.3 & 9.1.4, Table 3, SI No. (v) b)(Average Flexural strength ) |
- |
0 |
|
- |
Clause 7.3 & 9.1.4, Table 3, SI No. (v) a)(Indivdual Flexural strength ) |
- |
0 |
|
- |
Clause 7.3 & 9.1.4, Table 3, SI No. (iv) b)(Average Tensile splitting strength ) |
- |
0 |
|
- |
Clause 7.3 & 9.1.4, Table 3, SI No. (iv) a)(Indivdual Tensile splitting strength ) |
- |
0 |
|
- |
Clause 7.3 & 9.1.4, Table 3, SI No. (iii) b) ii)(Wet Abrasion resistance (Average of three test specimens)) |
- |
0 |
|
- |
Clause 7.3 & 9.1.4, Table 3, SI No. (iii) b) i)( Indivdual Wet Abrasion Resistance ) |
- |
0 |
|
- |
Clause 7.3 & 9.1.4, Table 3, SI No. (iii) a) ii)(Dry Abrasion resistance (Average of three test specimens)) |
- |
0 |
|
- |
Clause 7.3 & 9.1.4, Table 3, SI No. (iii) a) i)( Indivdual Dry Abrasion Resistance ) |
- |
0 |
|
- |
Clause 7.3 & 9.1.4, Table 3, SI No. (ii) b)(Compressive strength (Average of eight test specimens)) |
- |
0 |
|
- |
Clause 7.3 & 9.1.4, Table 3, SI No. (ii) a)( Indivdual Compressive strength) |
- |
0 |
|
- |
Clause 7.3 & 9.1.4, Table 3, SI No. (i) b)(Water absorption (Average of three test specimens)) |
- |
0 |
|
- |
Clause 7.3 & 9.1.4, Table 3, SI No. (i) a)( Indivdual Water absorption) |
- |
0 |
|
- |
Clause 7.2 & 9.1.3, Table 2, SI No. (ix)(Deviation from squareness) |
- |
0 |
|
- |
Clause 7.2 & 9.1.3, Table 2, SI No. (viii)(Indivdual Ratio of wearing face area and Plan area (Asw/Asp)) |
- |
0 |
|
- |
Clause 7.2 & 9.1.3, Table 2, SI No. (viii)(Ratio of wearing face area and Plan area (Asw/Asp)) |
- |
0 |
|
- |
Clause 7.2 & 9.1.3, Table 2, SI No. (vii)(Indivdual Plan Area (Asp)) |
- |
0 |
|
- |
Clause 7.2 & 9.1.3, Table 2, SI No. (vii)(Plan Area (Asp)) |
- |
0 |
|
- |
Clause 7.2 & 9.1.3, Table 2, SI No. (vi)(Indivdual Thickness of wearing Layer) |
- |
0 |
|
- |
Clause 7.2 & 9.1.3, Table 2, SI No. (vi)(Thickness of wearing Layer) |
- |
0 |
|
- |
Clause 7.2 & 9.1.3, Table 2, SI No. (v)(Indivdual Arris/chamfer, Depth) |
- |
0 |
|
- |
Clause 7.2 & 9.1.3, Table 2, SI No. (v)(Arris/chamfer, Depth) |
- |
0 |
|
- |
Clause 7.2 & 9.1.3, Table 2, SI No. (v)(Indivdual Arris/chamfer, Width) |
- |
0 |
|
- |
Clause 7.2 & 9.1.3, Table 2, SI No. (v)(Arris/chamfer, Width) |
- |
0 |
|
- |
Clause 7.2, Table No. 2, SI No. (iv)
(Indivdual Aspect Ratio, L/Th) |
- |
0 |
|
- |
Clause 7.2, Table No. 2, SI No. (iv)
(Aspect Ratio, L/Th) |
- |
0 |
|
- |
Clause 7.2, Table No. 2, SI No. (iii)
(Indivdual Thickness, Th) |
- |
0 |
|
- |
Clause 7.2, Table No. 2, SI No. (iii)
(Thickness, Th) |
- |
0 |
|
- |
Clause 7.2, Table No. 2, SI No. (ii)
(Indivdual Length, L) |
- |
0 |
|
- |
Clause 7.2, Table No. 2, SI No. (ii)
(Length, L) |
- |
0 |
|
- |
Clause 7.2, Table No. 2, SI No. (i)
(Indivdual Width, W) |
- |
0 |
|
- |
Clause 7.2, Table No. 2, SI No. (i)
(Width, W) |
- |
0 |
|
- |
Clause 6.3
(Bonding and Delamination between the layers of paver blocks) |
- |
0 |
|
- |
Clause 7.1.3
(Colour and Texture) |
- |
0 |
|
- |
Clauses 7.1.2 & 9.1.2
(Visual Inspection) |
- |
0 |
|
- |
Clause 7.1.1
(General Quality) |
- |
0 |
|
- |
7.2- TABLE-2- (i) IS-15658 (Annex-B)(Individual Width - Lower) |
- |
0 |
|
- |
7.2- TABLE-2- (i) IS-15658 (Annex-B)(Average Width -Lower) |
- |
0 |
|
- |
7.2- TABLE-2- (i) IS-15658 (Annex-B)(Individual Width - Higher) |
- |
0 |
|
- |
7.2- TABLE-2- (i) IS-15658 (Annex-B)(Average Width -Higher) |
- |
0 |
|
- |
Clause 3.20(Spacer nibs) |
- |
0 |
|
- |
10(Marking) |
- |
0 |
|
- |
cl.5(Cement) |
- |
0 |
|
- |
5.2(Mineral Admixture) |
- |
0 |
|
- |
5.3(Chemical Admixtures) |
- |
0 |
|
- |
5.4(Coarse and Fine
Aggregates) |
- |
0 |
|
- |
5.5(Pigments) |
- |
0 |
|
- |
5.6(Water) |
- |
0 |
|
- |
Clause 7.3 & 9.1.4, Table 3, SI No. (vi)(Freeze Thaw durability (Visual Rating of specimen after 50 cycles) |
- |
0 |
|
- |
Clause 7.3 & 9.1.4, Table 3, SI No. (vi)(Freeze Thaw durability (Visual Rating of specimen after 25 cycles) |
- |
0 |
|
- |
Clause 7.3 & 9.1.4, Table 3, SI No. (vi)(Freeze Thaw durability (Visual Rating of specimen after 10 cycles) |
- |
0 |
|
- |
Clause 7.3 & 9.1.4, Table 3, SI No. (vi)(Freeze Thaw durability (Cumulative Weight losses of specimen after 10, 25 & 50 cycles) |
- |
0 |
|
- |
Clause 7.3 & 9.1.4, Table 3, SI No. (vi)(Freeze Thaw durability (Weight losses of specimen after 50 cycles) |
- |
0 |
|
- |
Clause 7.3 & 9.1.4, Table 3, SI No. (vi)(Freeze Thaw durability (Weight losses of specimen after 25 cycles) |
- |
0 |
|
- |
Clause 7.3 & 9.1.4, Table 3, SI No. (vi)(Freeze Thaw durability (Weight losses of specimen after 10 cycles) |
- |
0 |
|
- |
Clause 7.3, Annex G(Average Breaking Load) |
- |
0 |
|
- |
Clause 7.3, Annex G(Individual Breaking Load) |
- |
0 |
|
- |
Clause 7.3, Annex F(Average Failure Load per unit Length) |
- |
0 |
|
- |
Clause 7.3, Annex F(Individual Failure Load per unit Length) |
- |
0 |
|
- |
Clause 7.3 & 9.1.4, Table 3, SI No. (v) b)(Average Flexural strength ) |
- |
0 |
|
- |
Clause 7.3 & 9.1.4, Table 3, SI No. (v) a)(Indivdual Flexural strength ) |
- |
0 |
|
- |
Clause 7.3 & 9.1.4, Table 3, SI No. (iv) b)(Average Tensile splitting strength ) |
- |
0 |
|
- |
Clause 7.3 & 9.1.4, Table 3, SI No. (iv) a)(Indivdual Tensile splitting strength ) |
- |
0 |
|
- |
Clause 7.3 & 9.1.4, Table 3, SI No. (iii) b) ii)(Wet Abrasion resistance (Average of three test specimens)) |
- |
0 |
|
- |
Clause 7.3 & 9.1.4, Table 3, SI No. (iii) b) i)( Indivdual Wet Abrasion Resistance ) |
- |
0 |
|
- |
Clause 7.3 & 9.1.4, Table 3, SI No. (iii) a) ii)(Dry Abrasion resistance (Average of three test specimens)) |
- |
0 |
|
- |
Clause 7.3 & 9.1.4, Table 3, SI No. (iii) a) i)( Indivdual Dry Abrasion Resistance ) |
- |
0 |
|
- |
Clause 7.3 & 9.1.4, Table 3, SI No. (ii) b)(Compressive strength (Average of eight test specimens)) |
- |
0 |
|
- |
Clause 7.3 & 9.1.4, Table 3, SI No. (ii) a)( Indivdual Compressive strength) |
- |
0 |
|
- |
Clause 7.3 & 9.1.4, Table 3, SI No. (i) b)(Water absorption (Average of three test specimens)) |
- |
0 |
|
- |
Clause 7.3 & 9.1.4, Table 3, SI No. (i) a)( Indivdual Water absorption) |
- |
0 |
|
- |
Clause 7.2 & 9.1.3, Table 2, SI No. (ix)(Deviation from squareness) |
- |
0 |
|
- |
Clause 7.2 & 9.1.3, Table 2, SI No. (viii)(Indivdual Ratio of wearing face area and Plan area (Asw/Asp)) |
- |
0 |
|
- |
Clause 7.2 & 9.1.3, Table 2, SI No. (viii)(Ratio of wearing face area and Plan area (Asw/Asp)) |
- |
0 |
|
- |
Clause 7.2 & 9.1.3, Table 2, SI No. (vii)(Indivdual Plan Area (Asp)) |
- |
0 |
|
- |
Clause 7.2 & 9.1.3, Table 2, SI No. (vii)(Plan Area (Asp)) |
- |
0 |
|
- |
Clause 7.2 & 9.1.3, Table 2, SI No. (vi)(Indivdual Thickness of wearing Layer) |
- |
0 |
|
- |
Clause 7.2 & 9.1.3, Table 2, SI No. (vi)(Thickness of wearing Layer) |
- |
0 |
|
- |
Clause 7.2 & 9.1.3, Table 2, SI No. (v)(Indivdual Arris/chamfer, Depth) |
- |
0 |
|
- |
Clause 7.2 & 9.1.3, Table 2, SI No. (v)(Arris/chamfer, Depth) |
- |
0 |
|
- |
Clause 7.2 & 9.1.3, Table 2, SI No. (v)(Indivdual Arris/chamfer, Width) |
- |
0 |
|
- |
Clause 7.2 & 9.1.3, Table 2, SI No. (v)(Arris/chamfer, Width) |
- |
0 |
|
- |
Clause 7.2, Table No. 2, SI No. (iv)
(Indivdual Aspect Ratio, L/Th) |
- |
0 |
|
- |
Clause 7.2, Table No. 2, SI No. (iv)
(Aspect Ratio, L/Th) |
- |
0 |
|
- |
Clause 7.2, Table No. 2, SI No. (iii)
(Indivdual Thickness, Th) |
- |
0 |
|
- |
Clause 7.2, Table No. 2, SI No. (iii)
(Thickness, Th) |
- |
0 |
|
- |
Clause 7.2, Table No. 2, SI No. (ii)
(Indivdual Length, L) |
- |
0 |
|
- |
Clause 7.2, Table No. 2, SI No. (ii)
(Length, L) |
- |
0 |
|
- |
Clause 7.2, Table No. 2, SI No. (i)
(Indivdual Width, W) |
- |
0 |
|
- |
Clause 7.2, Table No. 2, SI No. (i)
(Width, W) |
- |
0 |
|
- |
Clause 6.3
(Bonding and Delamination between the layers of paver blocks) |
- |
0 |
|
- |
Clause 7.1.3
(Colour and Texture) |
- |
0 |
|
- |
Clauses 7.1.2 & 9.1.2
(Visual Inspection) |
- |
0 |
|
- |
Clause 7.1.1
(General Quality) |
- |
0 |
|
- |
7.2- TABLE-2- (i) IS-15658 (Annex-B)(Individual Width - Lower) |
- |
0 |
|
- |
7.2- TABLE-2- (i) IS-15658 (Annex-B)(Average Width -Lower) |
- |
0 |
|
- |
7.2- TABLE-2- (i) IS-15658 (Annex-B)(Individual Width - Higher) |
- |
0 |
|
- |
7.2- TABLE-2- (i) IS-15658 (Annex-B)(Average Width -Higher) |
- |
0 |
|
- |
Clause 3.20(Spacer nibs) |
- |
0 |
|
- |
10(Marking) |
- |
0 |
|
- |
cl.5(Cement) |
- |
0 |
|
- |
5.2(Mineral Admixture) |
- |
0 |
|
- |
5.3(Chemical Admixtures) |
- |
0 |
|
- |
5.4(Coarse and Fine
Aggregates) |
- |
0 |
|
- |
5.5(Pigments) |
- |
0 |
|
- |
5.6(Water) |
- |
0 |
|
- |
|
Complete
|
|
01 Dec, 2027 |
- Included w.e.f.10.03.2025 |
1296 |
Elutech Laboratory and Calibration Services
| IS 2618 (2016) |
Laboratory glassware - Test tubes (Third Revision) |
. |
-
|
10000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
Cl. No. 4, Table no. 1(i)("Water resistance
") |
- |
0 |
|
- |
Cl. No. 4, Table no. 1(ii)(Acid resistance) |
- |
0 |
|
- |
Cl. No. 4, Table no. 1(ii)(Alkali resistance) |
- |
0 |
|
- |
Cl. No. 5, Table no.2 to 4(Construction and dimensions) |
- |
10000 |
|
- |
Cl. No. 6("Marking
") |
- |
10000 |
|
- |
Cl. No. 4, Table no. 1(i)("Water resistance
") |
- |
0 |
|
- |
Cl. No. 4, Table no. 1(ii)(Acid resistance) |
- |
0 |
|
- |
Cl. No. 4, Table no. 1(ii)(Alkali resistance) |
- |
0 |
|
- |
Cl. No. 5, Table no.2 to 4(Construction and dimensions) |
- |
10000 |
|
- |
Cl. No. 6("Marking
") |
- |
10000 |
|
- |
|
Complete
|
|
- |
- Included w.e.f.13.02.2025 |
1297 |
Aaditech Test and Calibration Lab LLP
| IS 11037 (2019) |
Electronic Type Fan Regulators — Specification ( First Revision ) |
ELECTRICAL |
-
|
10000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
9.1 (a)(Marking ) |
- |
1000 |
|
- |
9.1 (b)(Marking ) |
- |
1000 |
|
- |
9.1 (c)(Marking ) |
- |
1000 |
|
- |
9.1 (d)(Marking ) |
- |
1000 |
|
- |
9.1 (e)(Marking ) |
- |
1000 |
|
- |
9.1 (f)(Marking ) |
- |
1000 |
|
- |
9.2(Marking ) |
- |
1000 |
|
- |
6.1(Design and General Construction) |
- |
1000 |
|
- |
6.2(Design and General Construction) |
- |
1000 |
|
- |
6.3(Design and General Construction) |
- |
1000 |
|
- |
6.5(Design and General Construction) |
- |
1000 |
|
- |
6.6(Design and General Construction) |
- |
1000 |
|
- |
9.5.1 , 7.3(Temperature Rise) |
- |
1000 |
|
- |
9.5.1 , 7.3 (a)(Temperature Rise ) |
- |
1000 |
|
- |
9.5.1 , 7.3 (b)(Temperature Rise) |
- |
1000 |
|
- |
9.5.1 , 7.3 (b)(Temperature Rise) |
- |
1000 |
|
- |
9.5.2, 7.2(Leakage Current Test(as per Cl.13.2 of IS 302 (Part 1).) |
- |
1000 |
|
- |
9.5.3(High Voltage Test) |
- |
1000 |
|
- |
9.5.5(Earthing Connection) |
- |
1000 |
|
- |
9.5.6(Protection against electric shock (as per Cl.8 of IS 302 (Part 1)) |
- |
1000 |
|
- |
7.6(General and safety requirements) |
- |
1000 |
|
- |
7.7(Voltage drop) |
- |
1000 |
|
- |
8.1(Performance) |
- |
1000 |
|
- |
8.2(Performance) |
- |
1000 |
|
- |
8.3(Performance) |
- |
1000 |
|
- |
9.5.7, 9.5.4(Moisture Resistance ) |
- |
1000 |
|
- |
7.4.1(a)(Mechanical strength ) |
- |
1000 |
|
- |
7.4.1(b)(Mechanical strength ) |
- |
1000 |
|
- |
9.5.9, 7.5, Table-1(Creepage Distances and Clearances (as per Cl. 29 of IS 302-1)) |
- |
1000 |
|
- |
9.5.9, 7.5, Table-1(Creepage Distances and Clearances (as per Cl. 29 of IS 302-1)) |
- |
1000 |
|
- |
9.5.11.2(Environmental Tests) |
- |
1000 |
|
- |
9.5.11.3(Environmental Tests) |
- |
1000 |
|
- |
9.5.11.4(Environmental Tests) |
- |
1000 |
|
- |
9.5.10( Electrical Endurance Test) |
- |
1000 |
|
- |
9.5.12(Resistance to Abnormal Heat and to Fire) |
- |
1000 |
|
- |
9.5.12.1(Resistance to Abnormal Heat and to Fire) |
- |
1000 |
|
- |
9.5.13(Resistance to Rusting ) |
- |
1000 |
|
- |
9.5.14(Checking of Dimensions) |
- |
1000 |
|
- |
9.1(Marking ) |
- |
1000 |
|
- |
9.1 (a)(Marking ) |
- |
1000 |
|
- |
9.1 (b)(Marking ) |
- |
1000 |
|
- |
9.1 (c)(Marking ) |
- |
1000 |
|
- |
9.1 (d)(Marking ) |
- |
1000 |
|
- |
9.1 (e)(Marking ) |
- |
1000 |
|
- |
9.1 (f)(Marking ) |
- |
1000 |
|
- |
9.2(Marking ) |
- |
1000 |
|
- |
6.1(Design and General Construction) |
- |
1000 |
|
- |
6.2(Design and General Construction) |
- |
1000 |
|
- |
6.3(Design and General Construction) |
- |
1000 |
|
- |
6.5(Design and General Construction) |
- |
1000 |
|
- |
6.6(Design and General Construction) |
- |
1000 |
|
- |
9.5.1 , 7.3(Temperature Rise) |
- |
1000 |
|
- |
9.5.1 , 7.3 (a)(Temperature Rise ) |
- |
1000 |
|
- |
9.5.1 , 7.3 (b)(Temperature Rise) |
- |
1000 |
|
- |
9.5.1 , 7.3 (b)(Temperature Rise) |
- |
1000 |
|
- |
9.5.1 , 7.3 (b)(Temperature Rise) |
- |
1000 |
|
- |
9.5.2, 7.2(Leakage Current Test(as per Cl.13.2 of IS 302 (Part 1).) |
- |
1000 |
|
- |
9.5.3(High Voltage Test) |
- |
1000 |
|
- |
9.5.5(Earthing Connection) |
- |
1000 |
|
- |
9.5.6(Protection against electric shock (as per Cl.8 of IS 302 (Part 1)) |
- |
1000 |
|
- |
7.6(General and safety requirements) |
- |
1000 |
|
- |
7.7(Voltage drop) |
- |
1000 |
|
- |
8.1(Performance) |
- |
1000 |
|
- |
8.2(Performance) |
- |
1000 |
|
- |
8.3(Performance) |
- |
1000 |
|
- |
9.5.7, 9.5.4(Moisture Resistance ) |
- |
1000 |
|
- |
7.4.1(Mechanical strength ) |
- |
1000 |
|
- |
7.4.1(a)(Mechanical strength ) |
- |
1000 |
|
- |
7.4.1(b)(Mechanical strength ) |
- |
1000 |
|
- |
9.5.8, (Mechanical strength (as per Cl.21.1 of IS 302-1:2008)) |
- |
1000 |
|
- |
9.5.9, 7.5, Table-1(Creepage Distances and Clearances (as per Cl. 29 of IS 302-1)) |
- |
1000 |
|
- |
9.5.9, 7.5, Table-1(Creepage Distances and Clearances (as per Cl. 29 of IS 302-1)) |
- |
1000 |
|
- |
9.5.10( Electrical Endurance Test) |
- |
1000 |
|
- |
9.5.11.2(Environmental Tests) |
- |
1000 |
|
- |
9.5.11.3(Environmental Tests) |
- |
1000 |
|
- |
9.5.11.4(Environmental Tests) |
- |
1000 |
|
- |
9.5.12(Resistance to Abnormal Heat and to Fire) |
- |
1000 |
|
- |
9.5.12.1(Resistance to Abnormal Heat and to Fire) |
- |
1000 |
|
- |
9.5.13(Resistance to Rusting ) |
- |
1000 |
|
- |
9.5.14(Checking of Dimensions) |
- |
1000 |
|
- |
9.5.8, (Mechanical strength (as per Cl.21.1 of IS 302-1:2008)) |
- |
1000 |
|
- |
9.5.1 , 7.3 (b)(Temperature Rise) |
- |
1000 |
|
- |
9.1 (a)(Marking ) |
- |
1000 |
|
- |
9.1 (b)(Marking ) |
- |
1000 |
|
- |
9.1 (c)(Marking ) |
- |
1000 |
|
- |
9.1 (d)(Marking ) |
- |
1000 |
|
- |
9.1 (e)(Marking ) |
- |
1000 |
|
- |
9.1 (f)(Marking ) |
- |
1000 |
|
- |
9.2(Marking ) |
- |
1000 |
|
- |
6.1(Design and General Construction) |
- |
1000 |
|
- |
6.2(Design and General Construction) |
- |
1000 |
|
- |
6.3(Design and General Construction) |
- |
1000 |
|
- |
6.5(Design and General Construction) |
- |
1000 |
|
- |
6.6(Design and General Construction) |
- |
1000 |
|
- |
9.5.1 , 7.3(Temperature Rise) |
- |
1000 |
|
- |
9.5.1 , 7.3 (a)(Temperature Rise ) |
- |
1000 |
|
- |
9.5.1 , 7.3 (b)(Temperature Rise) |
- |
1000 |
|
- |
9.5.1 , 7.3 (b)(Temperature Rise) |
- |
1000 |
|
- |
9.5.2, 7.2(Leakage Current Test(as per Cl.13.2 of IS 302 (Part 1).) |
- |
1000 |
|
- |
9.5.3(High Voltage Test) |
- |
1000 |
|
- |
9.5.5(Earthing Connection) |
- |
1000 |
|
- |
9.5.6(Protection against electric shock (as per Cl.8 of IS 302 (Part 1)) |
- |
1000 |
|
- |
7.6(General and safety requirements) |
- |
1000 |
|
- |
7.7(Voltage drop) |
- |
1000 |
|
- |
8.1(Performance) |
- |
1000 |
|
- |
8.2(Performance) |
- |
1000 |
|
- |
8.3(Performance) |
- |
1000 |
|
- |
9.5.7, 9.5.4(Moisture Resistance ) |
- |
1000 |
|
- |
7.4.1(a)(Mechanical strength ) |
- |
1000 |
|
- |
7.4.1(b)(Mechanical strength ) |
- |
1000 |
|
- |
9.5.9, 7.5, Table-1(Creepage Distances and Clearances (as per Cl. 29 of IS 302-1)) |
- |
1000 |
|
- |
9.5.9, 7.5, Table-1(Creepage Distances and Clearances (as per Cl. 29 of IS 302-1)) |
- |
1000 |
|
- |
9.5.11.2(Environmental Tests) |
- |
1000 |
|
- |
9.5.11.3(Environmental Tests) |
- |
1000 |
|
- |
9.5.11.4(Environmental Tests) |
- |
1000 |
|
- |
9.5.10( Electrical Endurance Test) |
- |
1000 |
|
- |
9.5.12(Resistance to Abnormal Heat and to Fire) |
- |
1000 |
|
- |
9.5.12.1(Resistance to Abnormal Heat and to Fire) |
- |
1000 |
|
- |
9.5.13(Resistance to Rusting ) |
- |
1000 |
|
- |
9.5.14(Checking of Dimensions) |
- |
1000 |
|
- |
9.1(Marking ) |
- |
1000 |
|
- |
9.1 (a)(Marking ) |
- |
1000 |
|
- |
9.1 (b)(Marking ) |
- |
1000 |
|
- |
9.1 (c)(Marking ) |
- |
1000 |
|
- |
9.1 (d)(Marking ) |
- |
1000 |
|
- |
9.1 (e)(Marking ) |
- |
1000 |
|
- |
9.1 (f)(Marking ) |
- |
1000 |
|
- |
9.2(Marking ) |
- |
1000 |
|
- |
6.1(Design and General Construction) |
- |
1000 |
|
- |
6.2(Design and General Construction) |
- |
1000 |
|
- |
6.3(Design and General Construction) |
- |
1000 |
|
- |
6.5(Design and General Construction) |
- |
1000 |
|
- |
6.6(Design and General Construction) |
- |
1000 |
|
- |
9.5.1 , 7.3(Temperature Rise) |
- |
1000 |
|
- |
9.5.1 , 7.3 (a)(Temperature Rise ) |
- |
1000 |
|
- |
9.5.1 , 7.3 (b)(Temperature Rise) |
- |
1000 |
|
- |
9.5.1 , 7.3 (b)(Temperature Rise) |
- |
1000 |
|
- |
9.5.1 , 7.3 (b)(Temperature Rise) |
- |
1000 |
|
- |
9.5.2, 7.2(Leakage Current Test(as per Cl.13.2 of IS 302 (Part 1).) |
- |
1000 |
|
- |
9.5.3(High Voltage Test) |
- |
1000 |
|
- |
9.5.5(Earthing Connection) |
- |
1000 |
|
- |
9.5.6(Protection against electric shock (as per Cl.8 of IS 302 (Part 1)) |
- |
1000 |
|
- |
7.6(General and safety requirements) |
- |
1000 |
|
- |
7.7(Voltage drop) |
- |
1000 |
|
- |
8.1(Performance) |
- |
1000 |
|
- |
8.2(Performance) |
- |
1000 |
|
- |
8.3(Performance) |
- |
1000 |
|
- |
9.5.7, 9.5.4(Moisture Resistance ) |
- |
1000 |
|
- |
7.4.1(Mechanical strength ) |
- |
1000 |
|
- |
7.4.1(a)(Mechanical strength ) |
- |
1000 |
|
- |
7.4.1(b)(Mechanical strength ) |
- |
1000 |
|
- |
9.5.8, (Mechanical strength (as per Cl.21.1 of IS 302-1:2008)) |
- |
1000 |
|
- |
9.5.9, 7.5, Table-1(Creepage Distances and Clearances (as per Cl. 29 of IS 302-1)) |
- |
1000 |
|
- |
9.5.9, 7.5, Table-1(Creepage Distances and Clearances (as per Cl. 29 of IS 302-1)) |
- |
1000 |
|
- |
9.5.10( Electrical Endurance Test) |
- |
1000 |
|
- |
9.5.11.2(Environmental Tests) |
- |
1000 |
|
- |
9.5.11.3(Environmental Tests) |
- |
1000 |
|
- |
9.5.11.4(Environmental Tests) |
- |
1000 |
|
- |
9.5.12(Resistance to Abnormal Heat and to Fire) |
- |
1000 |
|
- |
9.5.12.1(Resistance to Abnormal Heat and to Fire) |
- |
1000 |
|
- |
9.5.13(Resistance to Rusting ) |
- |
1000 |
|
- |
9.5.14(Checking of Dimensions) |
- |
1000 |
|
- |
9.5.8, (Mechanical strength (as per Cl.21.1 of IS 302-1:2008)) |
- |
1000 |
|
- |
9.5.1 , 7.3 (b)(Temperature Rise) |
- |
1000 |
|
- |
7.1, 7.5.4(Insulation Resistance) |
- |
1000 |
|
- |
|
Complete
|
03 Sep, 2024 |
28 Aug, 2027 |
- Included w.e.f 03.02.2025 |
1298 |
RTC cum Technology Back up Unit for Solar Thermal Devices
| IS 16543 (2024) |
All-glass evacuated solar collector tubes - Specification (First revision) |
Non-Concentrating Type Solar Collector Hot water O/P |
-
|
7500 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
Cl 7.2.2(Uniformity) |
- |
0 |
|
GST Extra |
Cl 7.4(Stagnation Performance Parameter Test) |
- |
750 |
|
GST Extra |
Cl 7.5(Stagnation Solar Irradiation Test) |
- |
750 |
|
GST Extra |
Cl 7.6(Average Heat Loss Coefficient Test) |
- |
750 |
|
GST Extra |
Cl 7.7(Vacuum Performance Test) |
- |
1000 |
|
GST Extra |
Cl 7.8(Resistance to Thermal Shock Test) |
- |
750 |
|
GST Extra |
Cl 7.9(Resistance to Impact Test) |
- |
500 |
|
GST Extra |
Cl 7.10(0 Resistance to Internal Pressure Test) |
- |
750 |
|
GST Extra |
Cl 7.11(Absorptivity and Emissivity Test of the Selective Coating) |
- |
1500 |
|
GST Extra |
Cl 5.1.1(Transmittance ratio ( material)) |
- |
250 |
|
GST Extra |
Cl 5.1.2(Bubble & crack (material)) |
- |
0 |
|
GST Extra |
Cl 5.1.3(Knots (material)) |
- |
0 |
|
GST Extra |
Cl 5.1.4(Solar absorbing ratio (material)) |
- |
0 |
|
GST Extra |
Cl 5.2.1(Scratch length and visibility) |
- |
0 |
|
GST Extra |
Cl 5.2.3(Colour fading area) |
- |
0 |
|
GST Extra |
Cl 5.2.6(Length of an all-glass evacuated solar collector tube) |
- |
0 |
|
GST Extra |
Cl 5.2.7(Bending of the all-glass evacuated solar collector tube) |
- |
0 |
|
GST Extra |
Cl 5.2.8(Cross-section of the open end) |
- |
0 |
|
GST Extra |
Cl 4.2 & table 1(Outer Diameter of Cover Glass Tube) |
- |
250 |
|
GST Extra |
Cl 4.2 & table 1(Outer Diameter of Inner Glass Tube Including Coating) |
- |
0 |
|
GST Extra |
Cl 4.2 & table 1(Tube Length) |
- |
0 |
|
GST Extra |
Cl 4.2 & table 1(The Thickness of Cover and Inner Glass Tube) |
- |
0 |
|
GST Extra |
Cl 4.2 & table 1(Sealed off Part Length) |
- |
0 |
|
GST Extra |
Cl 4.3(Absorber Area for Different Tube Sizes) |
- |
0 |
|
GST Extra |
Cl 4.5(Calculation for Number of Tubes for The Heating System) |
- |
0 |
|
GST Extra |
Cl 4.1(Structure of All-Glass Evacuated Solar Collector Tube) |
- |
0 |
|
GST Extra |
Cl 5.2.2(Appearance of selective coating) |
- |
0 |
|
GST Extra |
Cl 5.2.5(The inner and cover tube at the open end) |
- |
0 |
|
GST Extra |
Cl 5.2.9(Sealed end) |
- |
0 |
|
GST Extra |
Cl 9(Marking) |
- |
250 |
|
GST Extra |
Cl 4.4(Solar Selective Absorbing Coating) |
- |
0 |
|
GST Extra |
Cl 5.2.4(Strut member) |
- |
0 |
|
GST Extra |
Cl 7.2.2(Uniformity) |
- |
0 |
|
GST Extra |
Cl 7.4(Stagnation Performance Parameter Test) |
- |
750 |
|
GST Extra |
Cl 7.5(Stagnation Solar Irradiation Test) |
- |
750 |
|
GST Extra |
Cl 7.6(Average Heat Loss Coefficient Test) |
- |
750 |
|
GST Extra |
Cl 7.7(Vacuum Performance Test) |
- |
1000 |
|
GST Extra |
Cl 7.8(Resistance to Thermal Shock Test) |
- |
750 |
|
GST Extra |
Cl 7.9(Resistance to Impact Test) |
- |
500 |
|
GST Extra |
Cl 7.10(0 Resistance to Internal Pressure Test) |
- |
750 |
|
GST Extra |
Cl 7.11(Absorptivity and Emissivity Test of the Selective Coating) |
- |
1500 |
|
GST Extra |
Cl 5.1.1(Transmittance ratio ( material)) |
- |
250 |
|
GST Extra |
Cl 5.1.2(Bubble & crack (material)) |
- |
0 |
|
GST Extra |
Cl 5.1.3(Knots (material)) |
- |
0 |
|
GST Extra |
Cl 5.1.4(Solar absorbing ratio (material)) |
- |
0 |
|
GST Extra |
Cl 5.2.1(Scratch length and visibility) |
- |
0 |
|
GST Extra |
Cl 5.2.3(Colour fading area) |
- |
0 |
|
GST Extra |
Cl 5.2.6(Length of an all-glass evacuated solar collector tube) |
- |
0 |
|
GST Extra |
Cl 5.2.7(Bending of the all-glass evacuated solar collector tube) |
- |
0 |
|
GST Extra |
Cl 5.2.8(Cross-section of the open end) |
- |
0 |
|
GST Extra |
Cl 4.2 & table 1(Outer Diameter of Cover Glass Tube) |
- |
250 |
|
GST Extra |
Cl 4.2 & table 1(Outer Diameter of Inner Glass Tube Including Coating) |
- |
0 |
|
GST Extra |
Cl 4.2 & table 1(Tube Length) |
- |
0 |
|
GST Extra |
Cl 4.2 & table 1(The Thickness of Cover and Inner Glass Tube) |
- |
0 |
|
GST Extra |
Cl 4.2 & table 1(Sealed off Part Length) |
- |
0 |
|
GST Extra |
Cl 4.3(Absorber Area for Different Tube Sizes) |
- |
0 |
|
GST Extra |
Cl 4.5(Calculation for Number of Tubes for The Heating System) |
- |
0 |
|
GST Extra |
Cl 4.1(Structure of All-Glass Evacuated Solar Collector Tube) |
- |
0 |
|
GST Extra |
Cl 5.2.2(Appearance of selective coating) |
- |
0 |
|
GST Extra |
Cl 5.2.5(The inner and cover tube at the open end) |
- |
0 |
|
GST Extra |
Cl 5.2.9(Sealed end) |
- |
0 |
|
GST Extra |
Cl 9(Marking) |
- |
250 |
|
GST Extra |
Cl 4.4(Solar Selective Absorbing Coating) |
- |
0 |
|
GST Extra |
Cl 5.2.4(Strut member) |
- |
0 |
|
GST Extra |
|
Complete
|
|
26 Oct, 2026 |
- Included.w.e.f.15.01.2025 |
1299 |
National Test House (WR), Mumbai
| IS 3854 (2023) |
Switches for Domestic and Similar Purposes - Specification (Third Revision) |
- |
-
|
13000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
Cl-4(General Requirements) |
- |
500 |
|
- |
Cl-5(General notes on tests) |
- |
500 |
|
- |
Cl-6(Rating) |
- |
500 |
|
- |
Cl-7(Classification) |
- |
500 |
|
- |
Cl-8(Marking) |
- |
500 |
|
- |
Cl-9(Checking of dimensions) |
- |
500 |
|
- |
Cl-10.1, 10.2(Prevention of Access to Live Parts) |
- |
500 |
|
- |
Cl-10.3(Requirements for Accessible Metal Parts) |
- |
500 |
|
- |
Cl-10.4(Requirements for Insulation of the Mechanism) |
- |
500 |
|
- |
Cl. 10.5(Requirements for Insulation of the Mechanism with Respect to the Surrounding Environment) |
- |
5000 |
|
- |
Cl-10.6(Requirements for Switches Operated Indirectly) |
- |
500 |
|
- |
Cl-10.7(Requirements for Switches with Replaceable Pull Cord) |
- |
500 |
|
- |
Cl-11(Provision for earthing) |
- |
500 |
|
- |
Cl-12(Terminals) |
- |
1000 |
|
- |
Cl-13(Constructional requirements) |
- |
500 |
|
- |
Cl-14(Mechanism) |
- |
1000 |
|
- |
Cl-15.1(Resistance to Ageing) |
- |
1500 |
|
- |
Cl-15.2(Protection Provided by Enclosures of Switches) |
- |
500 |
|
- |
Cl-15.3(Resistance to Humidity) |
- |
1500 |
|
- |
Cl-16.1(General) |
- |
500 |
|
- |
Cl-16.2(Test for Measuring the Insulation Resistance) |
- |
500 |
|
- |
Cl-16.3(Electric Strength Test) |
- |
1000 |
|
- |
Cl-17(Temperature rise) |
- |
1000 |
|
- |
Cl-18(Making and breaking capacity) |
- |
500 |
|
- |
Cl-19(Normal operation) |
- |
2500 |
|
- |
Cl-20(Mechanical strength) |
- |
500 |
|
- |
Cl-21(Resistance to heat) |
- |
1000 |
|
- |
Cl-22(Screws, current carrying parts and connections) |
- |
500 |
|
- |
Cl-23(Creepage distances, clearances and distance through sealing compound) |
- |
500 |
|
- |
Cl-24.1(Resistance to abnormal heat and fire) |
- |
1000 |
|
- |
Cl-24.2(Resistance to tracking) |
- |
500 |
|
- |
Cl-25(Resistance to rusting) |
- |
500 |
|
- |
19.1(Test for Switches Intended for Inductive Loads) |
- |
1000 |
|
- |
19.2(Test for Switches Intended for Externally Ballasted Lamp Loads) |
- |
2500 |
|
- |
19.3(Test for Switches Intended for Self-ballasted Lamp Loads) |
- |
2500 |
|
- |
13.5(Attachment of knobs) |
- |
1000 |
|
- |
12.3.11(Table 11)(Test Current for the Verification of Electrical and Thermal Stresses in Normal Use of Screwless Terminals) |
- |
1000 |
|
- |
12.3.12(Table 13)(Deflection Test Forces) |
- |
500 |
|
- |
Cl-4(General Requirements) |
- |
500 |
|
- |
Cl-5(General notes on tests) |
- |
500 |
|
- |
Cl-6(Rating) |
- |
500 |
|
- |
Cl-7(Classification) |
- |
500 |
|
- |
Cl-8(Marking) |
- |
500 |
|
- |
Cl-9(Checking of dimensions) |
- |
500 |
|
- |
Cl-10.1, 10.2(Prevention of Access to Live Parts) |
- |
500 |
|
- |
Cl-10.3(Requirements for Accessible Metal Parts) |
- |
500 |
|
- |
Cl-10.4(Requirements for Insulation of the Mechanism) |
- |
500 |
|
- |
Cl. 10.5(Requirements for Insulation of the Mechanism with Respect to the Surrounding Environment) |
- |
500 |
|
- |
Cl-10.6(Requirements for Switches Operated Indirectly) |
- |
1000 |
|
- |
Cl-10.7(Requirements for Switches with Replaceable Pull Cord) |
- |
1000 |
|
- |
Cl-11(Provision for earthing) |
- |
500 |
|
- |
Cl-12(Terminals) |
- |
500 |
|
- |
Cl-13(Constructional requirements) |
- |
500 |
|
- |
Cl-14(Mechanism) |
- |
500 |
|
- |
Cl-15.1(Resistance to Ageing) |
- |
1000 |
|
- |
Cl-15.2(Protection Provided by Enclosures of Switches) |
- |
500 |
|
- |
Cl-15.3(Resistance to Humidity) |
- |
1000 |
|
- |
Cl-16.1(General) |
- |
500 |
|
- |
Cl-16.2(Test for Measuring the Insulation Resistance) |
- |
500 |
|
- |
Cl-16.3(Electric Strength Test) |
- |
500 |
|
- |
Cl-17(Temperature rise) |
- |
1000 |
|
- |
Cl-18(Making and breaking capacity) |
- |
1500 |
|
- |
Cl-19(Normal operation) |
- |
2000 |
|
- |
Cl-20(Mechanical strength) |
- |
500 |
|
- |
Cl-21(Resistance to heat) |
- |
1000 |
|
- |
Cl-22(Screws, current carrying parts and connections) |
- |
500 |
|
- |
Cl-23(Creepage distances, clearances and distance through sealing compound) |
- |
500 |
|
- |
Cl-24.1(Resistance to abnormal heat and fire) |
- |
500 |
|
- |
Cl-24.2(Resistance to tracking) |
- |
500 |
|
- |
Cl-25(Resistance to rusting) |
- |
500 |
|
- |
19.1(Test for Switches Intended for Inductive Loads) |
- |
500 |
|
- |
19.2(Test for Switches Intended for Externally Ballasted Lamp Loads) |
- |
1500 |
|
- |
19.3(Test for Switches Intended for Self-ballasted Lamp Loads) |
- |
1500 |
|
- |
13.5(Attachment of knobs) |
- |
500 |
|
- |
12.3.11(Table 11)(Test Current for the Verification of Electrical and Thermal Stresses in Normal Use of Screwless Terminals) |
- |
1000 |
|
- |
12.3.12(Table 13)(Deflection Test Forces) |
- |
500 |
|
- |
Cl-4(General Requirements) |
- |
500 |
|
- |
Cl-5(General notes on tests) |
- |
500 |
|
- |
Cl-6(Rating) |
- |
500 |
|
- |
Cl-7(Classification) |
- |
500 |
|
- |
Cl-8(Marking) |
- |
500 |
|
- |
Cl-9(Checking of dimensions) |
- |
500 |
|
- |
Cl-10.1, 10.2(Prevention of Access to Live Parts) |
- |
500 |
|
- |
Cl-10.3(Requirements for Accessible Metal Parts) |
- |
500 |
|
- |
Cl-10.4(Requirements for Insulation of the Mechanism) |
- |
500 |
|
- |
Cl. 10.5(Requirements for Insulation of the Mechanism with Respect to the Surrounding Environment) |
- |
500 |
|
- |
Cl-10.6(Requirements for Switches Operated Indirectly) |
- |
500 |
|
- |
Cl-10.7(Requirements for Switches with Replaceable Pull Cord) |
- |
500 |
|
- |
Cl-11(Provision for earthing) |
- |
500 |
|
- |
Cl-12(Terminals) |
- |
500 |
|
- |
Cl-13(Constructional requirements) |
- |
500 |
|
- |
Cl-14(Mechanism) |
- |
500 |
|
- |
Cl-15.1(Resistance to Ageing) |
- |
1000 |
|
- |
Cl-15.2(Protection Provided by Enclosures of Switches) |
- |
500 |
|
- |
Cl-15.3(Resistance to Humidity) |
- |
1000 |
|
- |
Cl-16.1(General) |
- |
500 |
|
- |
Cl-16.2(Test for Measuring the Insulation Resistance) |
- |
500 |
|
- |
Cl-16.3(Electric Strength Test) |
- |
500 |
|
- |
Cl-17(Temperature rise) |
- |
1000 |
|
- |
Cl-18(Making and breaking capacity) |
- |
1000 |
|
- |
Cl-19(Normal operation) |
- |
1500 |
|
- |
Cl-20(Mechanical strength) |
- |
500 |
|
- |
Cl-21(Resistance to heat) |
- |
1000 |
|
- |
Cl-22(Screws, current carrying parts and connections) |
- |
500 |
|
- |
Cl-23(Creepage distances, clearances and distance through sealing compound) |
- |
500 |
|
- |
Cl-24.1(Resistance to abnormal heat and fire) |
- |
1000 |
|
- |
Cl-24.2(Resistance to tracking) |
- |
500 |
|
- |
Cl-25(Resistance to rusting) |
- |
500 |
|
- |
19.1(Test for Switches Intended for Inductive Loads) |
- |
1500 |
|
- |
19.2(Test for Switches Intended for Externally Ballasted Lamp Loads) |
- |
1500 |
|
- |
19.3(Test for Switches Intended for Self-ballasted Lamp Loads) |
- |
1500 |
|
- |
13.5(Attachment of knobs) |
- |
500 |
|
- |
12.3.11(Table 11)(Test Current for the Verification of Electrical and Thermal Stresses in Normal Use of Screwless Terminals) |
- |
500 |
|
- |
12.3.12(Table 13)(Deflection Test Forces) |
- |
500 |
|
- |
|
Complete
|
|
24 Jul, 2025 |
- Included .w.e.f.06.02.2025 |
1300 |
National Test House (WR), Mumbai
| IS 1258 (2024) |
Bayonet lampholders (Fifth Revision) |
- |
-
|
12000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
4(General requirements) |
- |
500 |
|
- |
6(Standard ratings) |
- |
500 |
|
- |
7(Classification) |
- |
500 |
|
- |
8(Marking) |
- |
1000 |
|
- |
9(Dimensions) |
- |
1500 |
|
- |
10(Protection against electric shock) |
- |
500 |
|
- |
11(Terminals) |
- |
1000 |
|
- |
12(Provision for earthing) |
- |
500 |
|
- |
13(Construction) |
- |
1000 |
|
- |
14(Switched lampholders) |
- |
1000 |
|
- |
15(Moisture resistance, insulation resistance and electrical strength) |
- |
2500 |
|
- |
16(Mechanical strength) |
- |
500 |
|
- |
17(Screws, current-carrying parts and connections) |
- |
500 |
|
- |
18(Creepage distances and clearances) |
- |
500 |
|
- |
19(General resistance to heat) |
- |
1000 |
|
- |
20(Resistance to heat, fire and tracking) |
- |
1000 |
|
- |
21(Resistance to excessive residual stresses (season cracking) and to rusting) |
- |
1000 |
|
- |
Annex A(Season cracking/corrosion test) |
- |
1000 |
|
- |
12.4(Thermal tests) |
- |
1000 |
|
- |
9.1(Lampholder dimensions) |
- |
1000 |
|
- |
11.2(Terminals) |
- |
1000 |
|
- |
12.3(Provision for earthing) |
- |
500 |
|
- |
13.1(Construction) |
- |
500 |
|
- |
13.8(Construction) |
- |
500 |
|
- |
14.4(Switched lampholders) |
- |
1000 |
|
- |
15.1(Moisture resistance, insulation resistance and electrical strength) |
- |
1000 |
|
- |
16.7(Mechanical strength) |
- |
500 |
|
- |
16.8(Mechanical strength) |
- |
500 |
|
- |
21.2(Resistance to excessive residual stresses (season cracking) and to rusting) |
- |
1000 |
|
- |
|
Complete
|
|
24 Jul, 2025 |
- Included.w.e.f.13.01.2025 |
1301 |
Testtex India Laboratories Pvt. Ltd., Mumbai
| IS 5405 (2019) |
Sanitary napkins – Specification (second revision) |
- |
-
|
15000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
3.1(Cover/Top sheet) |
- |
500 |
|
Complete Test Charges - Rs 11,000 + GST [Except Cl.7.6-Phthalates]; Complete Test Charges - Rs 15,000 + GST [Including Cl.7.6-Phthalates]; All Prices are Except Cl.7.4 - Biocompatibility Evaluation-Cytotoxicity, Irritation and Skin Sensitization & Cl.7.5 |
3.2(Absorbent Core) |
- |
500 |
|
NA |
3.3(Barrier or Bottom Sheet) |
- |
200 |
|
NA |
4.1 (1)(Type and shapes of sanitary napkins) |
- |
200 |
|
NA |
4.2(Sanitary napkins shape & design) |
- |
200 |
|
NA |
Cl 5(SIZES, Regular ) |
- |
125 |
|
Except Cl.7.4-Biocompatibility Evaluation-Cytotoxicity, Irritation and Skin Sensitization. Cl.7.5-Biodegradibility and Compost ability (Optional) |
Cl 5(SIZES, Large) |
- |
125 |
|
NA |
Cl 5(SIZES, Extra Large) |
- |
125 |
|
NA |
Cl 5(Absorbent Capacity, Regular ) |
- |
0 |
|
NA |
Cl 5(Absorbent Capacity, Large) |
- |
0 |
|
NA |
Cl 5(Absorbent Capacity, Extra Large) |
- |
0 |
|
NA |
Cl 5(Absorbent Capacity, XXL) |
- |
0 |
|
NA |
Cl 5(SIZES, Regular ) |
- |
0 |
|
- |
Cl 5(SIZES, Large) |
- |
0 |
|
- |
Cl 5(SIZES, Extra Large) |
- |
0 |
|
- |
Cl 5(SIZES, XXL) |
- |
125 |
|
- |
Cl 5(Absorbent Capacity, Regular ) |
- |
0 |
|
- |
Cl 5(Absorbent Capacity, Large) |
- |
0 |
|
- |
Cl 5(Absorbent Capacity, Extra Large) |
- |
0 |
|
- |
Cl 5(Absorbent Capacity, XXL) |
- |
0 |
|
- |
6.0(Manufacture, workmanship & finish) |
- |
400 |
|
NA |
Cl 7.2(Ability to Withstand Pressure after Absorption, for all sizes, Annex B) |
- |
600 |
|
NA |
Cl 7.3.1(Bacterial and Fungal Bioburden, 7.3.1.1, ISO 11737 (Part 1)) |
- |
5000 |
|
NA |
Cl7.3.2(Test for Common Skin Pathogen — Staphylococcus
Aureus, 7.3.2.1, IS 5887 (Part 2)) |
- |
2500 |
|
- |
7.6(Pthalate test) |
- |
4000 |
|
- |
Cl 7.1(pH Value, IS 1390 (cold method) for all sizes) |
- |
400 |
|
NA |
|
Complete
|
|
08 Apr, 2028 |
- Cl 7.4 (Biocompatibility Evaluation — Cytotoxicity, Irritation and Skin Sensitization), Cl 7.5 (Biodegradability and Compostability (Optional) |
1302 |
National Test House (NR)
| IS 15769 (2008) |
Flux cored (Tubular) electrodes for gas shielded and self - Shielded metal welding of carbon or carbon - Manganese steel |
All |
-
|
20000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
5.2(Radiographic Soundness Test) |
- |
1000 |
|
Complete Testing Charges. |
5.3 (Table No.- 1)(Tensile Test(T.S., Y.S. & El), Mpa-IS 1608) |
- |
5000 |
|
Complete Testing Charges. |
5.4 (Table No.- 2)(Impact Test,J- IS 1757) |
- |
5000 |
|
Complete Testing Charges. |
5.5 (Table No.- 1)(Transverse Tensile Test,Mpa (T.S., Y.S. & El)) |
- |
5000 |
|
Complete Testing Charges. |
5.6(Longitudinal Bend Test) |
- |
2000 |
|
Complete Testing Charges. |
5.7(Diffusible Hydrogen Test,ml/100g- IS 11802) |
- |
5000 |
|
Complete Testing Charges. |
5.8 (Table No.- 15)(Chemical Composition,%) |
- |
5000 |
|
Complete Testing Charges. |
5.2(Radiographic Soundness Test) |
- |
1000 |
|
Complete Testing Charges. |
5.3 (Table No.- 1)(Tensile Test(T.S., Y.S. & El), Mpa-IS 1608) |
- |
5000 |
|
Complete Testing Charges. |
5.4 (Table No.- 2)(Impact Test,J- IS 1757) |
- |
5000 |
|
Complete Testing Charges. |
5.5 (Table No.- 1)(Transverse Tensile Test,Mpa (T.S., Y.S. & El)) |
- |
5000 |
|
Complete Testing Charges. |
5.6(Longitudinal Bend Test) |
- |
2000 |
|
Complete Testing Charges. |
5.7(Diffusible Hydrogen Test,ml/100g- IS 11802) |
- |
5000 |
|
Complete Testing Charges. |
5.8 (Table No.- 15)(Chemical Composition,%) |
- |
5000 |
|
Complete Testing Charges. |
5.2(Radiographic Soundness Test) |
- |
1000 |
|
Complete Testing Charges. |
5.3 (Table No.- 1)(Tensile Test(T.S., Y.S. & El), Mpa-IS 1608) |
- |
5000 |
|
Complete Testing Charges. |
5.4 (Table No.- 2)(Impact Test,J- IS 1757) |
- |
5000 |
|
Complete Testing Charges. |
5.5 (Table No.- 1)(Transverse Tensile Test,Mpa (T.S., Y.S. & El)) |
- |
5000 |
|
Complete Testing Charges. |
5.6(Longitudinal Bend Test) |
- |
2000 |
|
Complete Testing Charges. |
5.7(Diffusible Hydrogen Test,ml/100g- IS 11802) |
- |
5000 |
|
Complete Testing Charges. |
5.8 (Table No.- 15)(Chemical Composition,%) |
- |
5000 |
|
Complete Testing Charges. |
5.2(Radiographic Soundness Test) |
- |
1000 |
|
Complete Testing Charges. |
5.3 (Table No.- 1)(Tensile Test(T.S., Y.S. & El), Mpa-IS 1608) |
- |
5000 |
|
Complete Testing Charges. |
5.4 (Table No.- 2)(Impact Test,J- IS 1757) |
- |
5000 |
|
Complete Testing Charges. |
5.5 (Table No.- 1)(Transverse Tensile Test,Mpa (T.S., Y.S. & El)) |
- |
5000 |
|
Complete Testing Charges. |
5.6(Longitudinal Bend Test) |
- |
1000 |
|
Complete Testing Charges. |
5.7(Diffusible Hydrogen Test,ml/100g- IS 11802) |
- |
5000 |
|
Complete Testing Charges. |
5.8 (Table No.- 15)(Chemical Composition,%) |
- |
5000 |
|
Complete Testing Charges. |
5.2(Radiographic Soundness Test) |
- |
1000 |
|
Complete Testing Charges |
5.3 (Table No.- 1)(Tensile Test(T.S., Y.S. & El), Mpa-IS 1608) |
- |
1000 |
|
Complete Testing Charges |
5.4 (Table No.- 2)(Impact Test,J- IS 1757) |
- |
1000 |
|
Complete Testing Charges |
5.5 (Table No.- 1)(Transverse Tensile Test,Mpa (T.S., Y.S. & El)) |
- |
1000 |
|
Complete Testing Charges |
5.6(Longitudinal Bend Test) |
- |
1000 |
|
Complete Testing Charges |
5.7(Diffusible Hydrogen Test,ml/100g- IS 11802) |
- |
1000 |
|
Complete Testing Charges |
5.8 (Table No.- 15)(Chemical Composition,%) |
- |
1000 |
|
Complete Testing Charges |
5.2(Radiographic Soundness Test) |
- |
1000 |
|
Complete Testing Charges |
5.3 (Table No.- 1)(Tensile Test(T.S., Y.S. & El), Mpa-IS 1608) |
- |
1000 |
|
Complete Testing Charges |
5.4 (Table No.- 2)(Impact Test,J- IS 1757) |
- |
1000 |
|
Complete Testing Charges |
5.5 (Table No.- 1)(Transverse Tensile Test,Mpa (T.S., Y.S. & El)) |
- |
1000 |
|
Complete Testing Charges |
5.6(Longitudinal Bend Test) |
- |
1000 |
|
Complete Testing Charges |
5.7(Diffusible Hydrogen Test,ml/100g- IS 11802) |
- |
1000 |
|
Complete Testing Charges |
5.8 (Table No.- 15)(Chemical Composition,%) |
- |
1000 |
|
Complete Testing Charges |
5.2(Radiographic Soundness Test) |
- |
1000 |
|
Complete Testing Charges |
5.3 (Table No.- 1)(Tensile Test(T.S., Y.S. & El), Mpa-IS 1608) |
- |
5000 |
|
Complete Testing Charges |
5.4 (Table No.- 2)(Impact Test,J- IS 1757) |
- |
5000 |
|
Complete Testing Charges |
5.5 (Table No.- 1)(Transverse Tensile Test,Mpa (T.S., Y.S. & El)) |
- |
5000 |
|
Complete Testing Charges |
5.6(Longitudinal Bend Test) |
- |
2000 |
|
Complete Testing Charges |
5.7(Diffusible Hydrogen Test,ml/100g- IS 11802) |
- |
5000 |
|
Complete Testing Charges |
5.8 (Table No.- 15)(Chemical Composition,%) |
- |
5000 |
|
Complete Testing Charges |
5.2(Radiographic Soundness Test) |
- |
1000 |
|
Complete Testing Charges |
5.3 (Table No.- 1)(Tensile Test(T.S., Y.S. & El), Mpa-IS 1608) |
- |
5000 |
|
Complete Testing Charges |
5.4 (Table No.- 2)(Impact Test,J- IS 1757) |
- |
5000 |
|
Complete Testing Charges |
5.5 (Table No.- 1)(Transverse Tensile Test,Mpa (T.S., Y.S. & El)) |
- |
5000 |
|
Complete Testing Charges |
5.6(Longitudinal Bend Test) |
- |
2000 |
|
Complete Testing Charges |
5.7(Diffusible Hydrogen Test,ml/100g- IS 11802) |
- |
5000 |
|
Complete Testing Charges |
5.8 (Table No.- 15)(Chemical Composition,%) |
- |
5000 |
|
Complete Testing Charges |
|
Complete
|
|
26 Oct, 2025 |
- Included w.e.f. 20.01.2025 |
1303 |
DELHI TEST HOUSE KUNDLI-2
| IS 7404 : Part 1 (1991) |
Paper covered copper conductors - Specification: Part 1 round conductors (First Revision) |
- |
-
|
12000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
4(General test conditions ) |
- |
500 |
|
- |
5(Conductor ) |
- |
500 |
|
- |
5.1(Material ) |
- |
500 |
|
- |
5.2(Diameter ) |
- |
2500 |
|
- |
6.1(Grade of Paper) |
- |
500 |
|
- |
7(Application of paper ) |
- |
500 |
|
- |
8(Overall diameter and increase in diameter ) |
- |
2500 |
|
- |
8.1(Double Paper Covering Ordinary (0) and Fine (F)) |
- |
500 |
|
- |
8.2(Multiple Paper Covering Special (S)) |
- |
1000 |
|
- |
8.3(Measuring Equipment) |
- |
1500 |
|
- |
8.4(Measuring Method) |
- |
1000 |
|
- |
9(Packing and marking ) |
- |
500 |
|
- |
4(General test conditions ) |
- |
500 |
|
- |
5(Conductor ) |
- |
500 |
|
- |
5.1(Material ) |
- |
500 |
|
- |
5.2(Diameter ) |
- |
2500 |
|
- |
6.1(Grade of Paper) |
- |
500 |
|
- |
7(Application of paper ) |
- |
500 |
|
- |
8(Overall diameter and increase in diameter ) |
- |
2500 |
|
- |
8.1(Double Paper Covering Ordinary (0) and Fine (F)) |
- |
500 |
|
- |
8.2(Multiple Paper Covering Special (S)) |
- |
1000 |
|
- |
8.3(Measuring Equipment) |
- |
1500 |
|
- |
8.4(Measuring Method) |
- |
1000 |
|
- |
9(Packing and marking ) |
- |
500 |
|
- |
|
Complete
|
|
31 Dec, 2026 |
- Included.w.e.f.15.01.2025 |
1304 |
Atmy Analytical Labs Private Limited (Unit-2)
| IS 302 : Part 1 (2024) |
Household and Similar Electrical Appliances â Safety Part 1 General Requirements (Seventh Revision) |
All |
-
|
45000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
12(Charging of metal-ion batteries) |
- |
0 |
|
- |
6(Classification) |
- |
0 |
|
- |
5(General conditions for the tests) |
- |
0 |
|
- |
11.8(Temperature rise) |
- |
0 |
|
- |
11.7(Duration corresponding) |
- |
0 |
|
- |
11.6(Combined appliances) |
- |
0 |
|
- |
11.5(Motor-operated appliances) |
- |
0 |
|
- |
11.4(Heating appliances) |
- |
0 |
|
- |
8.1.5(Live parts of built-in appliances) |
- |
0 |
|
- |
18(Endurance) |
- |
0 |
|
- |
17(Overload protection of transformers and associated circuits) |
- |
0 |
|
- |
16(Leakage current and electric strength) |
- |
0 |
|
- |
4(General requirement) |
- |
0 |
|
- |
32(Radiation Toxicity and Similar Hazards) |
- |
0 |
|
- |
31(Resistance to Rusting) |
- |
0 |
|
- |
30.2(Needle Flame Test) |
- |
0 |
|
- |
30.2(Glow Wire Test) |
- |
0 |
|
- |
30.1(Ball pressure test) |
- |
0 |
|
- |
29(clearance, creepage distances and solid insulation) |
- |
0 |
|
- |
28(Screw test and connections) |
- |
0 |
|
- |
27(Provision for earthing) |
- |
0 |
|
- |
26(Terminals for external conductors) |
- |
0 |
|
- |
25(Supply connection and external flexible cords) |
- |
0 |
|
- |
24(Components) |
- |
0 |
|
- |
23(Internal wiring) |
- |
0 |
|
- |
22(Construction) |
- |
0 |
|
- |
21(Mechanical Strength) |
- |
0 |
|
- |
20(Stability and mechanical hazards) |
- |
0 |
|
- |
19(Abnormal Operation) |
- |
0 |
|
- |
18(Endurance) |
- |
0 |
|
- |
17(Over Load Protection of Transformers and associated circuits) |
- |
0 |
|
- |
16.3(Electric Strength (after clause 15 and 16.2)) |
- |
0 |
|
- |
16.2(Leakage Current (after Clause 15)) |
- |
0 |
|
- |
16.1(General) |
- |
0 |
|
- |
16.0(General) |
- |
0 |
|
- |
15.3(Humidity Test) |
- |
0 |
|
- |
15.2(Spillage Test) |
- |
0 |
|
- |
15.1(Ingress Protection test other than IPX0 (IP test)) |
- |
0 |
|
- |
15.0(Moisture resistance) |
- |
0 |
|
- |
14(Transient Over Voltages) |
- |
0 |
|
- |
13.3(Electric Strength at operating temperature) |
- |
0 |
|
- |
13.2(Leakage current at operating temperature) |
- |
0 |
|
- |
13(Leakage current and electric strength at operating temperature) |
- |
0 |
|
- |
11.3(Heating) |
- |
0 |
|
- |
11.2(General) |
- |
0 |
|
- |
11.1(General) |
- |
0 |
|
- |
10.2(Current input) |
- |
0 |
|
- |
10.1(Power input) |
- |
0 |
|
- |
9(Starting of motor operation test requirements and tests) |
- |
0 |
|
- |
8.1.4(Protection against live parts against protective impedance) |
- |
0 |
|
- |
8.1.3(Protection against live parts in visible glowing heating elements) |
- |
0 |
|
- |
8.1.2(Protection against live parts in openings) |
- |
0 |
|
- |
8.1.1(Protection against live parts in all positions) |
- |
0 |
|
- |
7(Marking and instructions) |
- |
0 |
|
- |
A.2(Earth continuity test) |
- |
0 |
|
- |
Annex C(Ageing test on motors) |
- |
0 |
|
- |
Annex D(Thermal motor protectors) |
- |
0 |
|
- |
15.2(Moisture resistance) |
- |
0 |
|
- |
19.17(Abnormal operation) |
- |
0 |
|
- |
20.1(Stability and mechanical hazards) |
- |
0 |
|
- |
21.2(Mechanical strength) |
- |
0 |
|
- |
21.3(Mechanical strength) |
- |
0 |
|
- |
22.5(Construction) |
- |
0 |
|
- |
22.6(Construction) |
- |
0 |
|
- |
22.11(Construction) |
- |
0 |
|
- |
22.16(Construction) |
- |
0 |
|
- |
22.32(Construction) |
- |
0 |
|
- |
22.42(Construction) |
- |
0 |
|
- |
23.3(Internal wiring) |
- |
0 |
|
- |
25(Supply connection and external flexible cords) |
- |
0 |
|
- |
25.7(Supply connection and external flexible cords) |
- |
0 |
|
- |
25.14(Supply connection and external flexible cords) |
- |
0 |
|
- |
25.15(Supply connection and external flexible cords) |
- |
0 |
|
- |
26.5(Terminals for external conductors) |
- |
0 |
|
- |
27.5(Provision for earthing) |
- |
0 |
|
- |
28.1(Screws and connections) |
- |
0 |
|
- |
B.22.1(Construction) |
- |
0 |
|
- |
B.22.3(Construction) |
- |
0 |
|
- |
B.22.4(Construction) |
- |
0 |
|
- |
B.22.5(Construction) |
- |
0 |
|
- |
12(Charging of metal-ion batteries) |
- |
0 |
|
- |
6(Classification) |
- |
0 |
|
- |
5(General conditions for the tests) |
- |
0 |
|
- |
11.8(Temperature rise) |
- |
0 |
|
- |
11.7(Duration corresponding) |
- |
0 |
|
- |
11.6(Combined appliances) |
- |
0 |
|
- |
11.5(Motor-operated appliances) |
- |
0 |
|
- |
11.4(Heating appliances) |
- |
0 |
|
- |
8.1.5(Live parts of built-in appliances) |
- |
0 |
|
- |
18(Endurance) |
- |
0 |
|
- |
17(Overload protection of transformers and associated circuits) |
- |
0 |
|
- |
16(Leakage current and electric strength) |
- |
0 |
|
- |
4(General requirement) |
- |
0 |
|
- |
32(Radiation Toxicity and Similar Hazards) |
- |
0 |
|
- |
31(Resistance to Rusting) |
- |
0 |
|
- |
30.2(Needle Flame Test) |
- |
0 |
|
- |
30.2(Glow Wire Test) |
- |
0 |
|
- |
30.1(Ball pressure test) |
- |
0 |
|
- |
29(clearance, creepage distances and solid insulation) |
- |
0 |
|
- |
28(Screw test and connections) |
- |
0 |
|
- |
27(Provision for earthing) |
- |
0 |
|
- |
26(Terminals for external conductors) |
- |
0 |
|
- |
25(Supply connection and external flexible cords) |
- |
0 |
|
- |
24(Components) |
- |
0 |
|
- |
23(Internal wiring) |
- |
0 |
|
- |
22(Construction) |
- |
0 |
|
- |
21(Mechanical Strength) |
- |
0 |
|
- |
20(Stability and mechanical hazards) |
- |
0 |
|
- |
19(Abnormal Operation) |
- |
0 |
|
- |
18(Endurance) |
- |
0 |
|
- |
17(Over Load Protection of Transformers and associated circuits) |
- |
0 |
|
- |
16.3(Electric Strength (after clause 15 and 16.2)) |
- |
0 |
|
- |
16.2(Leakage Current (after Clause 15)) |
- |
0 |
|
- |
16.1(General) |
- |
0 |
|
- |
16.0(General) |
- |
0 |
|
- |
15.3(Humidity Test) |
- |
0 |
|
- |
15.2(Spillage Test) |
- |
0 |
|
- |
15.1(Ingress Protection test other than IPX0 (IP test)) |
- |
0 |
|
- |
15.0(Moisture resistance) |
- |
0 |
|
- |
14(Transient Over Voltages) |
- |
0 |
|
- |
13.3(Electric Strength at operating temperature) |
- |
0 |
|
- |
13.2(Leakage current at operating temperature) |
- |
0 |
|
- |
13(Leakage current and electric strength at operating temperature) |
- |
0 |
|
- |
11.3(Heating) |
- |
0 |
|
- |
11.2(General) |
- |
0 |
|
- |
11.1(General) |
- |
0 |
|
- |
10.2(Current input) |
- |
0 |
|
- |
10.1(Power input) |
- |
0 |
|
- |
9(Starting of motor operation test requirements and tests) |
- |
0 |
|
- |
8.1.4(Protection against live parts against protective impedance) |
- |
0 |
|
- |
8.1.3(Protection against live parts in visible glowing heating elements) |
- |
0 |
|
- |
8.1.2(Protection against live parts in openings) |
- |
0 |
|
- |
8.1.1(Protection against live parts in all positions) |
- |
0 |
|
- |
7(Marking and instructions) |
- |
0 |
|
- |
A.2(Earth continuity test) |
- |
0 |
|
- |
Annex C(Ageing test on motors) |
- |
0 |
|
- |
Annex D(Thermal motor protectors) |
- |
0 |
|
- |
15.2(Moisture resistance) |
- |
0 |
|
- |
19.17(Abnormal operation) |
- |
0 |
|
- |
20.1(Stability and mechanical hazards) |
- |
0 |
|
- |
21.2(Mechanical strength) |
- |
0 |
|
- |
21.3(Mechanical strength) |
- |
0 |
|
- |
22.5(Construction) |
- |
0 |
|
- |
22.6(Construction) |
- |
0 |
|
- |
22.11(Construction) |
- |
0 |
|
- |
22.16(Construction) |
- |
0 |
|
- |
22.32(Construction) |
- |
0 |
|
- |
22.42(Construction) |
- |
0 |
|
- |
23.3(Internal wiring) |
- |
0 |
|
- |
25(Supply connection and external flexible cords) |
- |
0 |
|
- |
25.7(Supply connection and external flexible cords) |
- |
0 |
|
- |
25.14(Supply connection and external flexible cords) |
- |
0 |
|
- |
25.15(Supply connection and external flexible cords) |
- |
0 |
|
- |
26.5(Terminals for external conductors) |
- |
0 |
|
- |
27.5(Provision for earthing) |
- |
0 |
|
- |
28.1(Screws and connections) |
- |
0 |
|
- |
B.22.1(Construction) |
- |
0 |
|
- |
B.22.3(Construction) |
- |
0 |
|
- |
B.22.4(Construction) |
- |
0 |
|
- |
B.22.5(Construction) |
- |
0 |
|
- |
|
Complete
|
|
08 Feb, 2027 |
- Included w.e.f 14.01.2025
Exclusion : Cl 19.11.4.1 - Cl 19.11.4.7 |
1305 |
BIS, Hyderabad Branch Laboratory (HYBL)
| IS 15907 (2010) |
Agro textiles – High density polyethylene (HDPE) woven beds for vermiculture – Specification |
- |
-
|
- View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
4.3 (Cord Beading - IS 15907) |
- |
|
|
|
5.2.1 (Thickness of coating film- method A of IS 13162 (Part 3)) |
- |
|
|
|
5.2.2 (coating thickness of the sandwich lamination- method A of IS 13162 (Part 3)) |
- |
|
|
|
5.3.1 (Construction- IS 15907) |
- |
|
|
|
5.3.1 (Construction- IS 15907) |
- |
|
|
|
5.3.1 (Construction- IS 15907) |
- |
|
|
|
5.3.1 (The width of the hem - IS 15907) |
- |
|
|
|
5.3.2 (Finished width of pocket - IS 15907) |
- |
|
|
|
5.4 (Bonding- IS 15907) |
- |
|
|
|
6- Table 1- SL.No (i) (Mass) |
- |
|
|
|
6- Table 1- SL.No (ii) (Breaking strength before UV exposure,warp - IS 1969 ) |
- |
|
|
|
6- Table 1- SL.No (ii) (Breaking strength before UV exposure,weft - IS 1969 ) |
- |
|
|
|
6- Table 1- SL.No (iii) (Elongation at break of fabric- IS 1969) |
- |
|
|
|
6- Table 1- SL.No (iv) (Retention of breaking strength after UV exposure, - Annex B of IS 15907 and IS 1969) |
- |
|
|
|
6- Table 1- SL.No (v) (Welded seam strength before UV exposure- IS 1969) |
- |
|
|
|
6- Table 1- SL.No (vi) (Welded seam strength after UV exposure- Annex B of IS 15907 and IS 1969) |
- |
|
|
|
6- Table 1- SL.No (vii) (Tear strength, Warp - Method A2 of IS 7016 (Part 3)) |
- |
|
|
|
6- Table 1- SL.No (vii) (Tear strength, Weft - Method A2 of IS 7016 (Part 3)) |
- |
|
|
|
6- Table 1- SL.No (viii) (Puncture strength - Annex C of IS 15907) |
- |
|
|
|
6.1 (Length -IS 15907) |
- |
|
|
|
6.1 (Width - IS 15907) |
- |
|
|
|
6.1 (Height - IS 15907) |
- |
|
|
|
4.1 (Linear Density) |
- |
|
|
|
4.1 (Width) |
- |
|
|
|
|
Partial
|
|
- |
- Except Raw material test, Colour fastness to artificial light, Bursting strength test, Environmental stress cracking test, Resistance to chemicals, change in the mass, Water Proofness and Limited test facility for UV stability test. |
1306 |
Novateur Electrical and Digital Systems Pvt Ltd ,Sinnar ,Nasik
| IS/IEC 60947 : Part 5 : Sec 1 (2016) |
Low-Voltage Switchgear And Control Gear : Part 5-1 Control Circuit Devices And Switching Elements Electromechanical Control Circuit Devices |
- |
-
|
251000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
7.1.2.2(Glow-wire testing) |
- |
5000 |
|
- |
7.1.4(Clearances and creepage distances) |
- |
10000 |
|
- |
7.2.3(Dielectric properties) |
- |
20000 |
|
- |
8.2.1.1.1(Glow-wire test) |
- |
5000 |
|
- |
8.2.5(Verification of actuating force (or moment)) |
- |
5000 |
|
- |
8.3.3.3(Temperature rise) |
- |
10000 |
|
- |
8.3.3.4(Dielectric properties) |
- |
20000 |
|
- |
8.3.4.2(Performance under conditional short-circuit current : Test procedure) |
- |
25000 |
|
- |
F 8.1.2.6("Dielectric test
after stresses") |
- |
14000 |
|
- |
F.8.1.2.1(Dielectric tests in new conditions) |
- |
20000 |
|
- |
K 8.3.4("Performance under
conditional shortcircuit current") |
- |
25000 |
|
- |
J.8.3.3.3(Temp-rise tests) |
- |
0 |
|
Testing facility not available already mentioned in application. |
J.8.3.3.4(Dielectric test) |
- |
0 |
|
Testing facility not available already mentioned in application. |
J.8.3.3.4.3("Dielectric test
(indicator lights
with built-in
transformers)") |
- |
0 |
|
Testing facility not available already mentioned in application. |
J.8.3.3.4(Dielectric test) |
- |
0 |
|
Testing facility not available already mentioned in application. |
J.8.3.3.4.3("Dielectric test
(indicator lights
with built-in
transformers)") |
- |
0 |
|
Testing facility not available already mentioned in application. |
J.8.3.3.3(Temp-rise tests) |
- |
0 |
|
Testing facility not available already mentioned in application. |
7.1.2.2(Glow-wire testing) |
- |
5000 |
|
- |
7.1.4(Clearances and creepage distances) |
- |
10000 |
|
- |
F.8.1.2.1(Dielectric tests in new conditions) |
- |
20000 |
|
- |
F 8.1.2.6("Dielectric test
after stresses") |
- |
14000 |
|
- |
8.3.4.2(Performance under conditional short-circuit current : Test procedure) |
- |
25000 |
|
- |
7.2.3(Dielectric properties) |
- |
20000 |
|
- |
8.3.3.4(Dielectric properties) |
- |
20000 |
|
- |
8.3.3.3(Temperature rise) |
- |
10000 |
|
- |
8.2.1.1.1(Glow-wire test) |
- |
5000 |
|
- |
K 8.3.4("Performance under
conditional shortcircuit current") |
- |
25000 |
|
- |
8.2.6(Verification of limitation of rotation (of a rotary switch)) |
- |
5000 |
|
- |
8.2.6(Verification of limitation of rotation (of a rotary switch)) |
- |
5000 |
|
- |
8.3.4(Performance under Conditional Short-Circuit Current) |
- |
25000 |
|
- |
8.3.3.5.6 b(Dielectric verification) |
- |
14000 |
|
- |
7.1.2.2(Glow-wire testing) |
- |
5000 |
|
- |
7.1.4(Clearances and creepage distances) |
- |
10000 |
|
- |
7.2.3(Dielectric properties) |
- |
20000 |
|
- |
8.2.1.1.1(Glow-wire test) |
- |
5000 |
|
- |
8.2.5(Verification of actuating force (or moment)) |
- |
5000 |
|
- |
8.3.3.3(Temperature rise) |
- |
10000 |
|
- |
8.3.3.4(Dielectric properties) |
- |
20000 |
|
- |
8.3.4.2(Performance under conditional short-circuit current : Test procedure) |
- |
25000 |
|
- |
F 8.1.2.6("Dielectric test
after stresses") |
- |
14000 |
|
- |
F.8.1.2.1(Dielectric tests in new conditions) |
- |
20000 |
|
- |
K 8.3.4("Performance under
conditional shortcircuit current") |
- |
25000 |
|
- |
7.1.2.2(Glow-wire testing) |
- |
5000 |
|
- |
7.1.4(Clearances and creepage distances) |
- |
10000 |
|
- |
F.8.1.2.1(Dielectric tests in new conditions) |
- |
20000 |
|
- |
F 8.1.2.6("Dielectric test
after stresses") |
- |
14000 |
|
- |
8.3.4.2(Performance under conditional short-circuit current : Test procedure) |
- |
25000 |
|
- |
7.2.3(Dielectric properties) |
- |
20000 |
|
- |
8.3.3.4(Dielectric properties) |
- |
20000 |
|
- |
8.3.3.3(Temperature rise) |
- |
10000 |
|
- |
8.2.1.1.1(Glow-wire test) |
- |
5000 |
|
- |
K 8.3.4("Performance under
conditional shortcircuit current") |
- |
25000 |
|
- |
8.2.6(Verification of limitation of rotation (of a rotary switch)) |
- |
5000 |
|
- |
8.2.6(Verification of limitation of rotation (of a rotary switch)) |
- |
5000 |
|
- |
8.3.4(Performance under Conditional Short-Circuit Current) |
- |
25000 |
|
- |
8.3.3.5.6 b(Dielectric verification) |
- |
14000 |
|
- |
|
Complete
|
29 Feb, 2024 |
21 Feb, 2027 |
- Included .w.e.f.11.02.2025
Capacity:
Short Circuit Test: 63A to 50kA @415V
Temperature rise test: Upto 4000A
Electrical Endurance test: Upto 2500A @ 415V
Mechanical Endurance test
HV (Upto 15kV AC/DC)
Leakage Current (Upto 300mA)
Impulse (Upto 20kVp)
Glow-wire test (on equipment)
only for sequence IV & VI |
1307 |
UL INDIA PRIVATE LIMITED
| IS 12640 : Part 1 (2024) |
Residual current operated circuitBreakers without integral overcurrent protection for household and similar uses Rccbs: Part 1 general rules (Third Revision) |
RCCB |
-
|
1545000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
6(Marking) |
- |
500 |
|
500 (For 1 Sample of DP), 500 (For 1 Sample of FP)
Total Test Charges: 12,20,000 (For3 samples of DP) & 15,45,000 (For3 samples of FP) |
8.1.1(General) |
- |
500 |
|
500 (For 1 Sample of DP), 500 (For 1 Sample of FP)
Total Test Charges: 12,20,000 (For3 samples of DP) & 15,45,000 (For3 samples of FP) |
8.1.2(Mechanism) |
- |
1500 |
|
1000 (For 1 Sample of DP), 1500 (For 1 Sample of FP)
Total Test Charges: 12,20,000 (For3 samples of DP) & 15,45,000 (For3 samples of FP) |
9.3(Indelibility of marking) |
- |
1000 |
|
1000 (For 1 Sample of DP), 1000 (For 1 Sample of FP)
Total Test Charges: 12,20,000 (For3 samples of DP) & 15,45,000 (For3 samples of FP) |
8.1.3(Clearance and creepage distance (External parts only)) |
- |
1500 |
|
1000 (For 1 Sample of DP) 1500 (For 1 Sample of FP)
Total Test Charges: 12,20,000 (For3 samples of DP) & 15,45,000 (For3 samples of FP) |
9.15(Trip free mechanism) |
- |
3500 |
|
2500 (For 1 Sample of DP) 3500 (For 1 Sample of FP)
Total Test Charges: 12,20,000 (For3 samples of DP) & 15,45,000 (For3 samples of FP) |
9.4(Reliability of screws, current-carrying parts and connections) |
- |
5000 |
|
3000 (For 1 Sample of DP) 5000 (For 1 Sample of FP)
Total Test Charges: 12,20,000 (For3 samples of DP) & 15,45,000 (For3 samples of FP) |
9.5(Reliability of terminals for external conductors) |
- |
5500 |
|
3500 (For 1 Sample of DP) 5500 (For 1 Sample of FP)
Total Test Charges: 12,20,000 (For3 samples of DP) & 15,45,000 (For3 samples of FP) |
9.6(Protection againts electrci shock) |
- |
4000 |
|
2000 (For 1 Sample of DP) 4000 (For 1 Sample of FP)
Total Test Charges: 12,20,000 (For3 samples of DP) & 15,45,000 (For3 samples of FP) |
9.13(Resistance to heat) |
- |
2500 |
|
2000 (For 1 Sample of DP) 2500 (For 1 Sample of FP)
Total Test Charges: 12,20,000 (For3 samples of DP) & 15,45,000 (For3 samples of FP) |
8.1.3(Clearance and creepage distance (Internal parts only)) |
- |
1500 |
|
1000 (For 1 Sample of DP) 1500 (For 1 Sample of FP)
Total Test Charges: 12,20,000 (For3 samples of DP) & 15,45,000 (For3 samples of FP) |
9.25(Resistance to rusting) |
- |
3000 |
|
2000 (For 1 Sample of DP) 3000 (For 1 Sample of FP)
Total Test Charges: 12,20,000 (For3 samples of DP) & 15,45,000 (For3 samples of FP) |
9.14(Resistance to abnormal heat and to fire) |
- |
20000 |
|
15000 (For 3 Samples of DP) 20000 (For 3 Samples of FP)
Total Test Charges: 12,20,000 (For3 samples of DP) & 15,45,000 (For3 samples of FP) |
9.7.7.4(Resistance of the insulation of open contacts and basic insulation against an impulse voltage in normal conditions) |
- |
13500 |
|
11000 (For 3 Samples of DP) 13500 (For 3 Samples of FP)
Total Test Charges: 12,20,000 (For3 samples of DP) & 15,45,000 (For3 samples of FP) |
9.7.7.5(Verification of the behaviour of components bridging the basic insulation) |
- |
12000 |
|
10000 (For 3 Samples of DP) 12000 (For 3 Samples of FP)
Total Test Charges: 12,20,000 (For3 samples of DP) & 15,45,000 (For3 samples of FP) |
9.7.1(Resistance to humidity) |
- |
15000 |
|
15000 (For 3 Samples of DP) 15000 (For 3 Samples of FP)
Total Test Charges: 12,20,000 (For3 samples of DP) & 15,45,000 (For3 samples of FP) |
9.7.2(Insulation resistance of the main circuit) |
- |
7500 |
|
5000 (For 3 Samples of DP) 7500 (For 3 Samples of FP)
Total Test Charges: 12,20,000 (For3 samples of DP) & 15,45,000 (For3 samples of FP) |
9.7.3(Dielectric strength of the main circuit) |
- |
7500 |
|
5000 (For 3 Samples of DP) 7500 (For 3 Samples of FP)
Total Test Charges: 12,20,000 (For3 samples of DP) & 15,45,000 (For3 samples of FP) |
9.7.4(Insulation resistance and dielectric strength of auxiliary circuits) |
- |
7500 |
|
5000 (For 3 Samples of DP) 7500 (For 3 Samples of FP)
Total Test Charges: 12,20,000 (For3 samples of DP) & 15,45,000 (For3 samples of FP) |
9.7.7.2(Verification of clearances with the impulse withstand voltage) |
- |
13500 |
|
11000 (For 3 Samples of DP) 13500 (For 3 Samples of FP)
Total Test Charges: 12,20,000 (For3 samples of DP) & 15,45,000 (For3 samples of FP) |
9.7.5(Secondary circuit of detection transformers) |
- |
11000 |
|
10000 (For 3 Samples of DP) 11000 (For 3 Samples of FP)
Total Test Charges: 12,20,000 (For3 samples of DP) & 15,45,000 (For3 samples of FP) |
9.7.6(Capability of control circuits connected to the main circuits etc.) |
- |
11000 |
|
10000 (For 3 Samples of DP) 11000 (For 3 Samples of FP)
Total Test Charges: 12,20,000 (For3 samples of DP) & 15,45,000 (For3 samples of FP) |
9.8(Temperature-rise) |
- |
18000 |
|
15000 (For 3 Samples of DP) 18000 (For 3 Samples of FP)
Total Test Charges: 12,20,000 (For3 samples of DP) & 15,45,000 (For3 samples of FP) |
9.22.2(Reliability at 40 °C) |
- |
38000 |
|
30000 (For 3 Samples of DP) 38000 (For 3 Samples of FP)
Total Test Charges: 12,20,000 (For3 samples of DP) & 15,45,000 (For3 samples of FP) |
9.23(Ageing of electronic components) |
- |
25500 |
|
23000 (For 3 Samples of DP) 25500 (For 3 Samples of FP)
Total Test Charges: 12,20,000 (For3 samples of DP) & 15,45,000 (For3 samples of FP) |
9.10(Mechanical and electrical endurance) |
- |
120000 |
|
80000 (For 3 Samples of DP) 120000 (For 3 Samples of FP)
Total Test Charges: 12,20,000 (For3 samples of DP) & 15,45,000 (For3 samples of FP) |
9.9(Residual operating characteristics) |
- |
101000 |
|
68000 (For 3 Samples of DP) 101000 (For 3 Samples of FP) - These tests charges are including 9.21 - DC component as per latest revision.
Total Test Charges: 12,20,000 (For3 samples of DP) & 15,45,000 (For3 samples of FP) |
9.17(Behaviour in the case of failure of the line voltage) |
- |
8000 |
|
6000 (For 3 Samples of DP) 8000 (For 3 Samples of FP)
Total Test Charges: 12,20,000 (For3 samples of DP) & 15,45,000 (For3 samples of FP) |
9.11.2.3a)b)(Perf ormance at IΔm) |
- |
60000 |
|
49000 (For 3 Samples of DP) 60000(For 3 Samples of FP)
Total Test Charges: 12,20,000 (For3 samples of DP) & 15,45,000 (For3 samples of FP) |
9.16(Test device) |
- |
3000 |
|
2000 (For 3 Samples of DP) 3000 (For 3 Samples of FP)
Total Test Charges: 12,20,000 (For3 samples of DP) & 15,45,000 (For3 samples of FP) |
9.12(Resistance to mechanical shock and impact) |
- |
11000 |
|
9000 (For 3 Samples of DP) 11000 (For 3 Samples of FP)
Total Test Charges: 12,20,000 (For3 samples of DP) & 15,45,000 (For3 samples of FP) |
9.18(Non-operating current under overcurrent conditions) |
- |
11000 |
|
9000 (For 3 Samples of DP) 11000 (For 3 Samples of FP)
Total Test Charges: 12,20,000 (For3 samples of DP) & 15,45,000 (For3 samples of FP) |
9.11.2.3c)(Verification of the suitability of RCCBs for use in IT-systems) |
- |
80000 |
|
60000 (For 3 Samples of DP) 80000 (For 3 Samples of FP)
Total Test Charges: 12,20,000 (For3 samples of DP) & 15,45,000 (For3 samples of FP) |
9.11.2.4 a)(Coordination at Inc) |
- |
75000 |
|
60000 (For 3 Samples of DP) 75000 (For 3 Samples of FP)
Total Test Charges: 12,20,000 (For3 samples of DP) & 15,45,000 (For3 samples of FP) |
9.11.2.4 c)(Performance at Im) |
- |
75000 |
|
60000 (For 3 Samples of DP) 75000 (For 3 Samples of FP)
Total Test Charges: 12,20,000 (For3 samples of DP) & 15,45,000 (For3 samples of FP) |
9.11.2.4 b)(Coordination at Im) |
- |
75000 |
|
60000 (For 3 Samples of DP) 75000 (For 3 Samples of FP)
Total Test Charges: 12,20,000 (For3 samples of DP) & 15,45,000 (For3 samples of FP) |
9.11.2.2(Coordination at IΔc) |
- |
75000 |
|
60000 (For 3 Samples of DP) 75000 (For 3 Samples of FP)
Total Test Charges: 12,20,000 (For3 samples of DP) & 15,45,000 (For3 samples of FP) |
9.22.1(Reliability (climatic test)) |
- |
90000 |
|
90000 (For 3 Samples of DP) 90000 (For 3 Samples of FP)
Total Test Charges: 12,20,000 (For3 samples of DP) & 15,45,000 (For3 samples of FP) |
IEC 61543, Table 5 –T2.3(Surges) |
- |
90000 |
|
60000 (For 3 Samples of DP) 90000 (For 3 Samples of FP)
Total Test Charges: 12,20,000 (For3 samples of DP) & 15,45,000 (For3 samples of FP) |
IEC 61543, Table 5 -T2.1(Conducted s ine-wave form voltages or c urrents) |
- |
60000 |
|
60000 (For 3 Samples of DP) 60000 (For 3 Samples of FP)
Total Test Charges: 12,20,000 (For3 samples of DP) & 15,45,000 (For3 samples of FP) |
IEC 61543, Table 5 -T2.1(Conducted s ine-wave form voltages or c urrents) |
- |
0 |
|
Duplicate clause |
IEC 61543, Table 5 -T2.5(Radiated electromagnetic field) |
- |
120000 |
|
120000 (For 3 Samples of DP) 120000 (For 3 Samples of FP)
Total Test Charges: 12,20,000 (For3 samples of DP) & 15,45,000 (For3 samples of FP) |
IEC 61543, Table 5 -T2.2(Fast transients (bursts)) |
- |
90000 |
|
60000 (For 3 Samples of DP) 90000 (For 3 Samples of FP)
Total Test Charges: 12,20,000 (For3 samples of DP) & 15,45,000 (For3 samples of FP) |
IEC 61543, Table 5 – T2.6(Conducted common mode disturbances in the frequency range lower than 150 kHz) |
- |
135000 |
|
90000 (For 3 Samples of DP) 135000 (For 3 Samples of FP)
Total Test Charges: 12,20,000 (For3 samples of DP) & 15,45,000 (For3 samples of FP) |
IEC 61543, Table 6 -T3.1(Electrostatic discharges) |
- |
20000 |
|
20000 (For 3 Samples of DP) 20000 (For 3 Samples of FP)
Total Test Charges: 12,20,000 (For3 samples of DP) & 15,45,000 (For3 samples of FP) |
9.19(Unwanted tripping Behaviour in the case of surge currents) |
- |
16000 |
|
12000 (For 3 Samples of DP) 16000 (For 3 Samples of FP) |
9.21(DC components) |
- |
0 |
|
Already covered into the Cl. 9.9 |
6(Marking) |
- |
0 |
|
- |
8.1.1(General) |
- |
0 |
|
- |
8.1.2(Mechanism) |
- |
0 |
|
- |
9.3(Indelibility of marking) |
- |
0 |
|
- |
8.1.3(Clearance and creepage distance (External parts only)) |
- |
0 |
|
- |
9.15(Trip free mechanism) |
- |
0 |
|
- |
9.4(Reliability of screws, current-carrying parts and connections) |
- |
0 |
|
- |
9.5(Reliability of terminals for external conductors) |
- |
0 |
|
- |
9.6(Protection againts electrci shock) |
- |
0 |
|
- |
9.13(Resistance to heat) |
- |
0 |
|
- |
8.1.3(Clearance and creepage distance (Internal parts only)) |
- |
0 |
|
- |
9.25(Resistance to rusting) |
- |
0 |
|
- |
9.14(Resistance to abnormal heat and to fire) |
- |
0 |
|
- |
9.7.7.4(Resistance of the insulation of open contacts and basic insulation against an impulse voltage in normal conditions) |
- |
0 |
|
- |
9.7.7.5(Verification of the behaviour of components bridging the basic insulation) |
- |
0 |
|
- |
9.7.1(Resistance to humidity) |
- |
0 |
|
- |
9.7.2(Insulation resistance of the main circuit) |
- |
0 |
|
- |
9.7.3(Dielectric strength of the main circuit) |
- |
0 |
|
- |
9.7.4(Insulation resistance and dielectric strength of auxiliary circuits) |
- |
0 |
|
- |
9.7.7.2(Verification of clearances with the impulse withstand voltage) |
- |
0 |
|
- |
9.7.5(Secondary circuit of detection transformers) |
- |
0 |
|
- |
9.7.6(Capability of control circuits connected to the main circuits etc.) |
- |
0 |
|
- |
9.8(Temperature-rise) |
- |
0 |
|
- |
9.22.2(Reliability at 40 °C) |
- |
0 |
|
- |
9.23(Ageing of electronic components) |
- |
0 |
|
- |
9.10(Mechanical and electrical endurance) |
- |
0 |
|
- |
9.9(Residual operating characteristics) |
- |
0 |
|
- |
9.17(Behaviour in the case of failure of the line voltage) |
- |
0 |
|
- |
9.11.2.3a)b)(Perf ormance at IΔm) |
- |
0 |
|
- |
9.16(Test device) |
- |
0 |
|
- |
9.12(Resistance to mechanical shock and impact) |
- |
0 |
|
- |
9.18(Non-operating current under overcurrent conditions) |
- |
0 |
|
- |
9.11.2.3c)(Verification of the suitability of RCCBs for use in IT-systems) |
- |
0 |
|
- |
9.11.2.4 a)(Coordination at Inc) |
- |
0 |
|
- |
9.11.2.4 c)(Performance at Im) |
- |
0 |
|
- |
9.11.2.4 b)(Coordination at Im) |
- |
0 |
|
- |
9.11.2.2(Coordination at IΔc) |
- |
0 |
|
- |
9.22.1(Reliability (climatic test)) |
- |
0 |
|
- |
IEC 61543, Table 5 –T2.3(Surges) |
- |
0 |
|
- |
IEC 61543, Table 5 -T2.1(Conducted s ine-wave form voltages or c urrents) |
- |
0 |
|
- |
IEC 61543, Table 5 -T2.1(Conducted s ine-wave form voltages or c urrents) |
- |
0 |
|
- |
IEC 61543, Table 5 -T2.5(Radiated electromagnetic field) |
- |
0 |
|
- |
IEC 61543, Table 5 -T2.2(Fast transients (bursts)) |
- |
0 |
|
- |
IEC 61543, Table 5 – T2.6(Conducted common mode disturbances in the frequency range lower than 150 kHz) |
- |
0 |
|
- |
IEC 61543, Table 6 -T3.1(Electrostatic discharges) |
- |
0 |
|
- |
9.19(Unwanted tripping Behaviour in the case of surge currents) |
- |
0 |
|
- |
|
Complete
|
|
12 May, 2027 |
- Included w.e.f. 27.01.2025 Exclusion:IEC 615432 , Table 4 -T1.1 (Harmonics, inter harmonics), IEC 61543, Table 4 -T1.2 (Signalling voltages), 9.21 (DC components). |
1308 |
BIS, Hyderabad Branch Laboratory (HYBL)
| IS 17070 (2019) |
Jute agrotextiles for growth of plant and suppression of weeds – Specification |
- |
-
|
- View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
5 -Table 1 -(i) (Mass at 20 percent moisture regain) |
- |
|
|
|
5 -Table 1 -(ii) (Thickness) |
- |
|
|
|
5 -Table 1 -(iii) (Width) |
- |
|
|
|
5 -Table 1 -(iv) (Wide width tensile strength) |
- |
|
|
|
5 -Table 1 -(v) (Tear strength) |
- |
|
|
|
5 -Table 1 -(vii) (Index Puncture resistance) |
- |
|
|
|
8 (Marking) |
- |
|
|
|
|
Partial
|
|
- |
- Except Air permeability test, Bursting strength. |
1309 |
SKC COMPLIANCE LAB PRIVATE LIMITED
| IS 302 : Part 1 (2008) |
Safety of household and similar electrical appliances: Part 1 general requirements (Sixth Revision) |
- |
-
|
80000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
7(Marking and instructions) |
- |
2000 |
|
10% discount for BIS |
8.1.1(Protection against live parts in all positions) |
- |
500 |
|
10% discount for BIS |
8.1.2(Protection against live parts in openings) |
- |
500 |
|
10% discount for BIS |
8.1.3(Protection against live parts in visible glowing heating elements) |
- |
250 |
|
10% discount for BIS |
8.1.4(Protection against live parts against protective impedance) |
- |
250 |
|
10% discount for BIS |
9(Starting of motor operation test requirements and tests) |
- |
0 |
|
10% discount for BIS |
10.1(Power input) |
- |
2500 |
|
10% discount for BIS |
10.2(Current input) |
- |
2500 |
|
10% discount for BIS |
11.1(General) |
- |
500 |
|
10% discount for BIS |
11.2(General) |
- |
500 |
|
10% discount for BIS |
11.3(Heating) |
- |
6500 |
|
10% discount for BIS |
13.1(General) |
- |
0 |
|
10% discount for BIS |
13.2(Leakage current at operating temperature) |
- |
2000 |
|
10% discount for BIS |
13.3(Electric Strength at operating temperature) |
- |
2000 |
|
10% discount for BIS |
14(Transient Over Voltages) |
- |
1000 |
|
10% discount for BIS |
15.0(General) |
- |
0 |
|
10% discount for BIS |
15.1(Ingress Protection test other than IPX0 (IP test)) |
- |
1500 |
|
10% discount for BIS |
15.2(Spillage Test) |
- |
500 |
|
10% discount for BIS |
15.3(Humidity Test) |
- |
8000 |
|
10% discount for BIS |
16.0(General) |
- |
0 |
|
10% discount for BIS |
16.1(General) |
- |
0 |
|
10% discount for BIS |
16.2(Leakage Current (after Clause 15)) |
- |
2000 |
|
10% discount for BIS |
16.3(Electric Strength (after clause 15 and 16.2)) |
- |
2000 |
|
10% discount for BIS |
17(Over Load Protection of Transformers and associated circuits) |
- |
2000 |
|
10% discount for BIS |
18(Endurance Test requirements and tests) |
- |
0 |
|
10% discount for BIS |
19(Abnormal Operation) |
- |
10000 |
|
10% discount for BIS |
20(Stability test) |
- |
1500 |
|
10% discount for BIS |
21(Mechanical Strength Test) |
- |
2000 |
|
10% discount for BIS |
22(Construction verification related test) |
- |
3000 |
|
10% discount for BIS |
23(General) |
- |
2000 |
|
10% discount for BIS |
24(Components) |
- |
5000 |
|
10% discount for BIS |
25(Supply connection and external flexible cords) |
- |
1500 |
|
10% discount for BIS |
26(Terminals for external conductors) |
- |
1500 |
|
10% discount for BIS |
27(Provision for earthing) |
- |
3000 |
|
10% discount for BIS |
28(Screw test and connections) |
- |
2000 |
|
10% discount for BIS |
29(clearance, creepage distances and solid insulation) |
- |
5000 |
|
10% discount for BIS |
30.1(Ball pressure test) |
- |
2000 |
|
10% discount for BIS |
30.2(Glow Wire Test) |
- |
1500 |
|
10% discount for BIS |
30.2(Needle Flame Test) |
- |
1500 |
|
10% discount for BIS |
31(Resistance to Rusting) |
- |
1500 |
|
10% discount for BIS |
32(Radiation Toxicity and Similar Hazards) |
- |
0 |
|
10% discount for BIS |
|
Complete
|
|
24 May, 2025 |
- EXCLUSIONS: Cl.19.11.4.1 to Cl.19.11.4.7 (EMI/EMC), 24 (Components). |
1310 |
SKC COMPLIANCE LAB PRIVATE LIMITED
| IS 616 (2017) |
Audio, video and similar electronic apparatus - Safety requirements (Fifth Revision) |
- |
-
|
90000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
5(Marking and instructions) |
- |
6000 |
|
10% discount for BIS |
7(Heating under normal operating conditions) |
- |
13000 |
|
10% discount for BIS |
8(Constructional requirements with regard to the protection against electric shock) |
- |
5000 |
|
10% discount for BIS |
9(Electric shock hazard under normal operating conditions) |
- |
5000 |
|
10% discount for BIS |
10(Insulation requirements) |
- |
12000 |
|
10% discount for BIS |
11(Fault conditions) |
- |
5000 |
|
10% discount for BIS |
12(Mechanical strength) |
- |
5000 |
|
10% discount for BIS |
13(CLEARANCES and CREEPAGE DISTANCES) |
- |
6000 |
|
10% discount for BIS |
14(Components) |
- |
6000 |
|
10% discount for BIS |
15(TERMINALS) |
- |
2500 |
|
10% discount for BIS |
16(External flexible cords) |
- |
6000 |
|
10% discount for BIS |
17(Electrical connections and mechanical fixings) |
- |
4000 |
|
10% discount for BIS |
18(Mechanical strength of picture tubes and protection against the effects of implosion) |
- |
0 |
|
10% discount for BIS |
19(Stability and mechanical hazards) |
- |
4000 |
|
10% discount for BIS |
20(Resistance to fire) |
- |
2500 |
|
10% discount for BIS |
8.16/ H 2.2/ H 2.3(Requirements for insulated winding wires for use without additional interleaved insulation) |
- |
1000 |
|
10% discount for BIS |
8.16(Wound Component) |
- |
1000 |
|
10% discount for BIS |
15(Internal wires and power cords) |
- |
2500 |
|
10% discount for BIS |
16.3b(Cord Bending Test) |
- |
1000 |
|
10% discount for BIS |
20.2.4(Printed Boards) |
- |
2500 |
|
10% discount for BIS |
|
Complete
|
|
24 May, 2025 |
- Exclusions : 6.1 (Ionizing radiation),6.2 (Laser Radiation), Cl 6.3 LED , 18 (Mechanical strength of Picture tubes and protection against the effect of implosion), 14 (Components). |
1311 |
BIS, Hyderabad Branch Laboratory (HYBL)
| IS 16202 (2014) |
Agro textiles - Woven ground covers for horticulture application - Specification |
- |
-
|
- View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
4.1 (Linear Density, Denier) |
- |
|
|
|
4.2 (Plain Weave & Sett, ends & picks/dm) |
- |
|
|
|
4.3 (Colour) |
- |
|
|
|
5.1, Table-1 (Mass, g/m² , IS 1964) |
- |
|
|
|
5.1, Table-1 (Tensile Test, Kgf, IS 1969,Part-2) |
- |
|
|
|
5.1, Table-1 (Tear Strength, Kgf, IS 6489,Part-1) |
- |
|
|
|
5.1, Table-1 (Index puncture resistance, kgf, Annexure-B) |
- |
|
|
|
5.1, Table-1 (UV accelerated exposure testing, Annexure-C) |
- |
|
|
|
5.1, Table-1 (Water permeability, lt/m2 /s, IS 14324) |
- |
|
|
|
5.2 (Dimension and Mass) |
- |
|
|
|
Clause No. 7 (Packing thickness) |
- |
|
|
|
|
Partial
|
|
- |
- Except Raw material test, Air permeability test, Water vapour permeability and Limited test facility for UV stability test. |
1312 |
BIS, Hyderabad Branch Laboratory (HYBL)
| IS 16513 (2016) |
Agro textiles “ Insect nets for agriculture and horticulture purposes “ Specification |
- |
-
|
- View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
6/6.1 ( REQUIREMENTS Dimensions and Mass a) Length) |
- |
|
|
|
6/6.1 ( REQUIREMENTS Dimensions and Mass b) width) |
- |
|
|
|
6/6.1 ( REQUIREMENTS Dimensions and Mass c) Mass gm/m2) |
- |
|
|
|
4.2 ( Netting Fabric) |
- |
|
|
|
4.2 ( Netting Fabric) |
- |
|
|
|
4.2 ( Netting Fabric) |
- |
|
|
|
5.0 (types a) Type I — having mesh of 30; b) Type II — having mesh of 40; andc) c) Type III — having mesh of 50) |
- |
|
|
|
4.3 ( Colour) |
- |
|
|
|
4.1 (Linear Density) |
- |
|
|
|
6.2/2 (Ends per Inch) |
- |
|
|
|
6.2/2 (Picks per Inch) |
- |
|
|
|
6.2/3 (cover factor) |
- |
|
|
|
6.2/4 (Breaking strength before U.V. Exposure (MD & TD)) |
- |
|
|
|
6.2/5 (UV exposure 144 hours (100x65 + 44x40)) |
- |
|
|
|
6.2/5 (Breaking strength after U.V. Exposure (MD & TD)) |
- |
|
|
|
|
Partial
|
|
- |
- Except Raw material test, Air permeability test, Bursting strength test and Limited test facility for UV stability test. |
1313 |
BIS, Hyderabad Branch Laboratory (HYBL)
| IS 16718 (2021) |
Textiles - Polypropylene Spun Bonded Non-Woven Crop Covers and Fruit Skirting Bags for Agricultural and Horticultural Applications - Specification (first revision) |
- |
-
|
- View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
5.2.2 (Width of fabric) |
- |
|
|
|
5.4.2 -Table 1-(i) (Mango, Orange) |
- |
|
|
|
5.4.2 -Table 1-(ii) (Banana bunch) |
- |
|
|
|
5.4.2 -Table 1-(iii) (Grape bunch) |
- |
|
|
|
5.4.2 -Table 1-(iv) (Pomegranate) |
- |
|
|
|
5.4.2 -Table 1-(v) (Papaya) |
- |
|
|
|
5.4.2 - Table 2 - (i) (Thickness) |
- |
|
|
|
5.4.2 - Table 2 - (ii) (Fabric mass) |
- |
|
|
|
5.4.2 - Table 2 - (iii) (Breaking strength) |
- |
|
|
|
5.4.2 - Table 2 - (iv) (Elongation at break) |
- |
|
|
|
5.4.2 - Table 2 - (v) (Trapezoid tear strength) |
- |
|
|
|
5.4.2 - Table 2 - (viii) (UV stability test) |
- |
|
|
|
5.4.2 - Table 2 - (ix) (Ash content) |
- |
|
|
|
5.4.2 - Table 2 - (x) (Index puncture resistance) |
- |
|
|
|
5.4.2 - Table 2 - (xii) (Colour) |
- |
|
|
|
8.1.2 (Marking) |
- |
|
|
|
|
Partial
|
|
- |
- Except Raw material test, Air permeability test, Water vapour permeability test, Water absorption capacity test and Limited test facility for UV stability test. |
1314 |
Stellar Test House
| IS 302 : Part 1 (2024) |
Household and Similar Electrical Appliances â Safety Part 1 General Requirements (Seventh Revision) |
- |
-
|
24000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
12(Charging of metal-ion batteries) |
- |
1500 |
|
- |
6(Classification) |
- |
100 |
|
- |
5(General conditions for the tests) |
- |
100 |
|
- |
11.8(Temperature rise) |
- |
1000 |
|
- |
11.7(Duration corresponding) |
- |
100 |
|
- |
11.6(Combined appliances) |
- |
100 |
|
- |
11.5(Motor-operated appliances) |
- |
100 |
|
- |
11.4(Heating appliances) |
- |
100 |
|
- |
8.1.5(Live parts of built-in appliances) |
- |
200 |
|
- |
18(Endurance) |
- |
100 |
|
- |
17(Overload protection of transformers and associated circuits) |
- |
600 |
|
- |
16(Leakage current and electric strength) |
- |
500 |
|
- |
4(General requirement) |
- |
100 |
|
- |
32(Radiation Toxicity and Similar Hazards) |
- |
400 |
|
- |
31(Resistance to Rusting) |
- |
500 |
|
- |
30.2(Needle Flame Test) |
- |
500 |
|
- |
30.2(Glow Wire Test) |
- |
500 |
|
- |
30.1(Ball pressure test) |
- |
500 |
|
- |
29(clearance, creepage distances and solid insulation) |
- |
500 |
|
- |
28(Screw test and connections) |
- |
500 |
|
- |
27(Provision for earthing) |
- |
1000 |
|
- |
26(Terminals for external conductors) |
- |
500 |
|
- |
25(Supply connection and external flexible cords) |
- |
500 |
|
- |
24(Components) |
- |
100 |
|
- |
23(Internal wiring) |
- |
400 |
|
- |
22(Construction) |
- |
500 |
|
- |
21(Mechanical Strength) |
- |
100 |
|
- |
20(Stability and mechanical hazards) |
- |
1000 |
|
- |
19(Abnormal Operation) |
- |
1000 |
|
- |
18(Endurance) |
- |
100 |
|
- |
17(Over Load Protection of Transformers and associated circuits) |
- |
600 |
|
- |
16.3(Electric Strength (after clause 15 and 16.2)) |
- |
500 |
|
- |
16.2(Leakage Current (after Clause 15)) |
- |
100 |
|
- |
16.1(General) |
- |
100 |
|
- |
16.0(General) |
- |
100 |
|
- |
15.3(Humidity Test) |
- |
2000 |
|
- |
15.2(Spillage Test) |
- |
300 |
|
- |
15.1(Ingress Protection test other than IPX0 (IP test)) |
- |
500 |
|
- |
15.0(Moisture resistance) |
- |
100 |
|
- |
14(Transient Over Voltages) |
- |
400 |
|
- |
13.3(Electric Strength at operating temperature) |
- |
500 |
|
- |
13.2(Leakage current at operating temperature) |
- |
500 |
|
- |
13(Leakage current and electric strength at operating temperature) |
- |
500 |
|
- |
11.3(Heating) |
- |
500 |
|
- |
11.2(General) |
- |
100 |
|
- |
11.1(General) |
- |
100 |
|
- |
10.2(Current input) |
- |
100 |
|
- |
10.1(Power input) |
- |
100 |
|
- |
9(Starting of motor operation test requirements and tests) |
- |
100 |
|
- |
8.1.4(Protection against live parts against protective impedance) |
- |
100 |
|
- |
8.1.3(Protection against live parts in visible glowing heating elements) |
- |
100 |
|
- |
8.1.2(Protection against live parts in openings) |
- |
100 |
|
- |
8.1.1(Protection against live parts in all positions) |
- |
100 |
|
- |
7(Marking and instructions) |
- |
100 |
|
- |
A.2(Earth continuity test) |
- |
100 |
|
- |
Annex C(Ageing test on motors) |
- |
100 |
|
- |
Annex D(Thermal motor protectors) |
- |
100 |
|
- |
15.2(Moisture resistance) |
- |
100 |
|
- |
19.17(Abnormal operation) |
- |
100 |
|
- |
20.1(Stability and mechanical hazards) |
- |
100 |
|
- |
21.2(Mechanical strength) |
- |
100 |
|
- |
21.3(Mechanical strength) |
- |
100 |
|
- |
22.5(Construction) |
- |
100 |
|
- |
22.6(Construction) |
- |
100 |
|
- |
22.11(Construction) |
- |
100 |
|
- |
22.16(Construction) |
- |
100 |
|
- |
22.32(Construction) |
- |
100 |
|
- |
22.42(Construction) |
- |
100 |
|
- |
23.3(Internal wiring) |
- |
100 |
|
- |
25(Supply connection and external flexible cords) |
- |
100 |
|
- |
25.7(Supply connection and external flexible cords) |
- |
100 |
|
- |
25.14(Supply connection and external flexible cords) |
- |
100 |
|
- |
25.15(Supply connection and external flexible cords) |
- |
100 |
|
- |
26.5(Terminals for external conductors) |
- |
100 |
|
- |
27.5(Provision for earthing) |
- |
100 |
|
- |
28.1(Screws and connections) |
- |
100 |
|
- |
B.22.1(Construction) |
- |
100 |
|
- |
B.22.3(Construction) |
- |
100 |
|
- |
B.22.4(Construction) |
- |
100 |
|
- |
B.22.5(Construction) |
- |
200 |
|
- |
12(Charging of metal-ion batteries) |
- |
1500 |
|
- |
6(Classification) |
- |
100 |
|
- |
5(General conditions for the tests) |
- |
100 |
|
- |
11.8(Temperature rise) |
- |
1000 |
|
- |
11.7(Duration corresponding) |
- |
100 |
|
- |
11.6(Combined appliances) |
- |
100 |
|
- |
11.5(Motor-operated appliances) |
- |
100 |
|
- |
11.4(Heating appliances) |
- |
100 |
|
- |
8.1.5(Live parts of built-in appliances) |
- |
200 |
|
- |
18(Endurance) |
- |
100 |
|
- |
17(Overload protection of transformers and associated circuits) |
- |
600 |
|
- |
16(Leakage current and electric strength) |
- |
200 |
|
- |
4(General requirement) |
- |
100 |
|
- |
32(Radiation Toxicity and Similar Hazards) |
- |
200 |
|
- |
31(Resistance to Rusting) |
- |
500 |
|
- |
30.2(Needle Flame Test) |
- |
500 |
|
- |
30.2(Glow Wire Test) |
- |
500 |
|
- |
30.1(Ball pressure test) |
- |
500 |
|
- |
29(clearance, creepage distances and solid insulation) |
- |
500 |
|
- |
28(Screw test and connections) |
- |
400 |
|
- |
27(Provision for earthing) |
- |
500 |
|
- |
26(Terminals for external conductors) |
- |
200 |
|
- |
25(Supply connection and external flexible cords) |
- |
1000 |
|
- |
24(Components) |
- |
200 |
|
- |
23(Internal wiring) |
- |
500 |
|
- |
22(Construction) |
- |
200 |
|
- |
21(Mechanical Strength) |
- |
700 |
|
- |
20(Stability and mechanical hazards) |
- |
400 |
|
- |
19(Abnormal Operation) |
- |
1000 |
|
- |
18(Endurance) |
- |
100 |
|
- |
17(Over Load Protection of Transformers and associated circuits) |
- |
600 |
|
- |
16.3(Electric Strength (after clause 15 and 16.2)) |
- |
500 |
|
- |
16.2(Leakage Current (after Clause 15)) |
- |
500 |
|
- |
16.1(General) |
- |
100 |
|
- |
16.0(General) |
- |
100 |
|
- |
15.3(Humidity Test) |
- |
500 |
|
- |
15.2(Spillage Test) |
- |
200 |
|
- |
15.1(Ingress Protection test other than IPX0 (IP test)) |
- |
200 |
|
- |
15.0(Moisture resistance) |
- |
500 |
|
- |
14(Transient Over Voltages) |
- |
100 |
|
- |
13.3(Electric Strength at operating temperature) |
- |
500 |
|
- |
13.2(Leakage current at operating temperature) |
- |
500 |
|
- |
13(Leakage current and electric strength at operating temperature) |
- |
500 |
|
- |
11.3(Heating) |
- |
1000 |
|
- |
11.2(General) |
- |
100 |
|
- |
11.1(General) |
- |
100 |
|
- |
10.2(Current input) |
- |
500 |
|
- |
10.1(Power input) |
- |
500 |
|
- |
9(Starting of motor operation test requirements and tests) |
- |
100 |
|
- |
8.1.4(Protection against live parts against protective impedance) |
- |
500 |
|
- |
8.1.3(Protection against live parts in visible glowing heating elements) |
- |
500 |
|
- |
8.1.2(Protection against live parts in openings) |
- |
500 |
|
- |
8.1.1(Protection against live parts in all positions) |
- |
500 |
|
- |
7(Marking and instructions) |
- |
200 |
|
- |
A.2(Earth continuity test) |
- |
400 |
|
- |
Annex C(Ageing test on motors) |
- |
200 |
|
- |
Annex D(Thermal motor protectors) |
- |
100 |
|
- |
15.2(Moisture resistance) |
- |
500 |
|
- |
19.17(Abnormal operation) |
- |
1000 |
|
- |
20.1(Stability and mechanical hazards) |
- |
500 |
|
- |
21.2(Mechanical strength) |
- |
200 |
|
- |
21.3(Mechanical strength) |
- |
200 |
|
- |
22.5(Construction) |
- |
100 |
|
- |
22.6(Construction) |
- |
100 |
|
- |
22.11(Construction) |
- |
200 |
|
- |
22.16(Construction) |
- |
100 |
|
- |
22.32(Construction) |
- |
100 |
|
- |
22.42(Construction) |
- |
100 |
|
- |
23.3(Internal wiring) |
- |
100 |
|
- |
25(Supply connection and external flexible cords) |
- |
100 |
|
- |
25.7(Supply connection and external flexible cords) |
- |
500 |
|
- |
25.14(Supply connection and external flexible cords) |
- |
100 |
|
- |
25.15(Supply connection and external flexible cords) |
- |
100 |
|
- |
26.5(Terminals for external conductors) |
- |
500 |
|
- |
27.5(Provision for earthing) |
- |
500 |
|
- |
28.1(Screws and connections) |
- |
400 |
|
- |
B.22.1(Construction) |
- |
200 |
|
- |
B.22.3(Construction) |
- |
200 |
|
- |
B.22.4(Construction) |
- |
100 |
|
- |
B.22.5(Construction) |
- |
100 |
|
- |
|
Complete
|
|
26 Sep, 2025 |
- Included w.e.f 25.03.2025
Exclusion: Cl 19.11.4.1 to Cl 19.11.4.1(EMI/EMC) |
1315 |
Testtex India Laboratories Pvt. Ltd., Mumbai
| IS 17514 (2021) |
Reusable Sanitary PadSanitary Napkin Period panties Specification |
- |
-
|
17000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
3.1(Material- Cover/Top sheet) |
- |
500 |
|
Complete Test Charges - Rs 17,000 + GST [Including Cl.9.5-Phthalates];Cl.10.0 - Anti Bacterial Activity Value (Optional Test) - Rs 4000 + GST (10% Discount to BIS for Complete Testing) |
3.2(Material- Absorbent Core) |
- |
500 |
|
- |
3.3(Material- Bottom Layer) |
- |
200 |
|
- |
4.0(Manufacturing , workmanship and finish) |
- |
400 |
|
- |
5.0(Fastening Mechanism) |
- |
200 |
|
- |
6.0(Sizes:- Pad Length and Pad Width (For Absorbent core only)) |
- |
125 |
|
- |
7.0(Washing , Drying And Handling Instruction) |
- |
200 |
|
- |
8 & 11.2.4, Table 1, (i)(Colour Fastness to Rubbing) |
- |
300 |
|
- |
8 & 11.2.4, Table 1, (ii)(Colour Fastness to Perspiration (Acidic & Alkaline)) |
- |
400 |
|
- |
8 & 11.2.4, Table 1, (iii)(Colour Fastness to Washing) |
- |
400 |
|
- |
8 & 11.2.4, Table 1, (iv)(Dimensional Stability to washing, percentage) |
- |
400 |
|
- |
9.1(pH Value) |
- |
400 |
|
- |
9.5(Phthalate Test: Di-n-butyl phthalate (DBP)) |
- |
4000 |
|
Rs. 4000 - Combined Testing Charges for Clause no. 9.5 Phthalate Test |
9.5(Phthalate Test: Benzyl butyl phthalate (BBP)) |
- |
4000 |
|
Rs. 4000 - Combined Testing Charges for Clause no. 9.5 Phthalate Test |
9.5(Phthalate Test: Bis- (2-ethylhexyl) phthalate (DEHP)) |
- |
4000 |
|
Rs. 4000 - Combined Testing Charges for Clause no. 9.5 Phthalate Test |
9.5(Phthalate Test: di-n-octyl phtahlate (DNOP)) |
- |
4000 |
|
Rs. 4000 - Combined Testing Charges for Clause no. 9.5 Phthalate Test |
9.5(Phthalate Test: Di-iso-nonyl phthalate (DINP)) |
- |
4000 |
|
Rs. 4000 - Combined Testing Charges for Clause no. 9.5 Phthalate Test |
9.5(Phthalate Test: Di-iso-decyl phthalate (DIDP)) |
- |
4000 |
|
Rs. 4000 - Combined Testing Charges for Clause no. 9.5 Phthalate Test |
9.3.1(Bacterial and Fungal Bioburden) |
- |
5000 |
|
- |
9.3.2(Test for Common Skin Pathogen -Staphylococcus Aureus) |
- |
2500 |
|
- |
Clasue No. 10(Anti-Bacterial Activity Value) |
- |
4000 |
|
Optional Test |
|
Complete
|
|
08 Apr, 2028 |
- - |
1316 |
Ace Test Labs & Metrology Pvt. Ltd.
| IS 302 : Part 1 (2024) |
Household and Similar Electrical Appliances â Safety Part 1 General Requirements (Seventh Revision) |
- |
-
|
43500 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
12(Charging of metal-ion batteries) |
- |
5000 |
|
- |
6(Classification) |
- |
500 |
|
- |
5(General conditions for the tests) |
- |
1000 |
|
- |
19.11.4.7(Harmonics) |
- |
25000 |
|
- |
19.11.4.6(Class 3 Voltage dips and interruptions) |
- |
25000 |
|
- |
19.11.4.5(Immunity to conducted discharges) |
- |
25000 |
|
- |
19.11.4.4(Surge immunity test) |
- |
25000 |
|
- |
19.11.4.3(Fast transient bursts) |
- |
25000 |
|
- |
19.11.4.2(Radiated fields) |
- |
25000 |
|
- |
19.11.4.1(Electrostatic discharges) |
- |
25000 |
|
- |
11.8(Temperature rise) |
- |
10000 |
|
- |
11.7(Duration corresponding) |
- |
1000 |
|
- |
11.6(Combined appliances) |
- |
25000 |
|
- |
11.5(Motor-operated appliances) |
- |
25000 |
|
- |
11.4(Heating appliances) |
- |
12000 |
|
- |
8.1.5(Live parts of built-in appliances) |
- |
5000 |
|
- |
18(Endurance) |
- |
15000 |
|
- |
17(Overload protection of transformers and associated circuits) |
- |
7500 |
|
- |
16(Leakage current and electric strength) |
- |
5000 |
|
- |
4(General requirement) |
- |
5000 |
|
- |
32(Radiation Toxicity and Similar Hazards) |
- |
10000 |
|
- |
31(Resistance to Rusting) |
- |
10000 |
|
- |
30.2(Needle Flame Test) |
- |
5000 |
|
- |
30.2(Glow Wire Test) |
- |
5000 |
|
- |
30.1(Ball pressure test) |
- |
5000 |
|
- |
29(clearance, creepage distances and solid insulation) |
- |
5000 |
|
- |
28(Screw test and connections) |
- |
5000 |
|
- |
27(Provision for earthing) |
- |
5000 |
|
- |
26(Terminals for external conductors) |
- |
5000 |
|
- |
25(Supply connection and external flexible cords) |
- |
5000 |
|
- |
24(Components) |
- |
5000 |
|
- |
23(Internal wiring) |
- |
1200 |
|
- |
22(Construction) |
- |
5000 |
|
- |
21(Mechanical Strength) |
- |
1000 |
|
- |
20(Stability and mechanical hazards) |
- |
1000 |
|
- |
19(Abnormal Operation) |
- |
2500 |
|
- |
18(Endurance) |
- |
5000 |
|
- |
17(Over Load Protection of Transformers and associated circuits) |
- |
5000 |
|
- |
16.3(Electric Strength (after clause 15 and 16.2)) |
- |
5000 |
|
- |
16.2(Leakage Current (after Clause 15)) |
- |
1500 |
|
- |
16.1(General) |
- |
1500 |
|
- |
16.0(General) |
- |
1500 |
|
- |
15.3(Humidity Test) |
- |
5000 |
|
- |
15.2(Spillage Test) |
- |
1500 |
|
- |
15.1(Ingress Protection test other than IPX0 (IP test)) |
- |
1500 |
|
- |
15.0(Moisture resistance) |
- |
1500 |
|
- |
14(Transient Over Voltages) |
- |
1500 |
|
- |
13.3(Electric Strength at operating temperature) |
- |
1500 |
|
- |
13.2(Leakage current at operating temperature) |
- |
1500 |
|
- |
13(Leakage current and electric strength at operating temperature) |
- |
1500 |
|
- |
11.3(Heating) |
- |
5000 |
|
- |
11.2(General) |
- |
1500 |
|
- |
11.1(General) |
- |
1500 |
|
- |
10.2(Current input) |
- |
1500 |
|
- |
10.1(Power input) |
- |
1500 |
|
- |
9(Starting of motor operation test requirements and tests) |
- |
1500 |
|
- |
8.1.4(Protection against live parts against protective impedance) |
- |
1500 |
|
- |
8.1.3(Protection against live parts in visible glowing heating elements) |
- |
1500 |
|
- |
8.1.2(Protection against live parts in openings) |
- |
1500 |
|
- |
8.1.1(Protection against live parts in all positions) |
- |
1500 |
|
- |
7(Marking and instructions) |
- |
1500 |
|
- |
A.2(Earth continuity test) |
- |
1500 |
|
- |
Annex C(Ageing test on motors) |
- |
1500 |
|
- |
Annex D(Thermal motor protectors) |
- |
1500 |
|
- |
15.2(Moisture resistance) |
- |
1500 |
|
- |
19.17(Abnormal operation) |
- |
1500 |
|
- |
20.1(Stability and mechanical hazards) |
- |
1500 |
|
- |
21.2(Mechanical strength) |
- |
1500 |
|
- |
21.3(Mechanical strength) |
- |
1500 |
|
- |
22.5(Construction) |
- |
1500 |
|
- |
22.6(Construction) |
- |
1500 |
|
- |
22.11(Construction) |
- |
1500 |
|
- |
22.16(Construction) |
- |
1500 |
|
- |
22.32(Construction) |
- |
1500 |
|
- |
22.42(Construction) |
- |
1500 |
|
- |
23.3(Internal wiring) |
- |
1500 |
|
- |
25(Supply connection and external flexible cords) |
- |
1500 |
|
- |
25.7(Supply connection and external flexible cords) |
- |
1500 |
|
- |
25.14(Supply connection and external flexible cords) |
- |
1500 |
|
- |
25.15(Supply connection and external flexible cords) |
- |
1500 |
|
- |
26.5(Terminals for external conductors) |
- |
1500 |
|
- |
27.5(Provision for earthing) |
- |
1500 |
|
- |
28.1(Screws and connections) |
- |
1500 |
|
- |
B.22.1(Construction) |
- |
1500 |
|
- |
B.22.3(Construction) |
- |
1500 |
|
- |
B.22.4(Construction) |
- |
1500 |
|
- |
B.22.5(Construction) |
- |
1500 |
|
- |
12(Charging of metal-ion batteries) |
- |
- |
|
- |
6(Classification) |
- |
- |
|
- |
5(General conditions for the tests) |
- |
- |
|
- |
19.11.4.7(Harmonics) |
- |
- |
|
- |
19.11.4.6(Class 3 Voltage dips and interruptions) |
- |
- |
|
- |
19.11.4.5(Immunity to conducted discharges) |
- |
- |
|
- |
19.11.4.4(Surge immunity test) |
- |
- |
|
- |
19.11.4.3(Fast transient bursts) |
- |
- |
|
- |
19.11.4.2(Radiated fields) |
- |
- |
|
- |
19.11.4.1(Electrostatic discharges) |
- |
- |
|
- |
11.8(Temperature rise) |
- |
- |
|
- |
11.7(Duration corresponding) |
- |
- |
|
- |
11.6(Combined appliances) |
- |
- |
|
- |
11.5(Motor-operated appliances) |
- |
- |
|
- |
11.4(Heating appliances) |
- |
- |
|
- |
8.1.5(Live parts of built-in appliances) |
- |
- |
|
- |
18(Endurance) |
- |
- |
|
- |
17(Overload protection of transformers and associated circuits) |
- |
- |
|
- |
16(Leakage current and electric strength) |
- |
- |
|
- |
4(General requirement) |
- |
- |
|
- |
32(Radiation Toxicity and Similar Hazards) |
- |
- |
|
- |
31(Resistance to Rusting) |
- |
- |
|
- |
30.2(Needle Flame Test) |
- |
- |
|
- |
30.2(Glow Wire Test) |
- |
- |
|
- |
30.1(Ball pressure test) |
- |
- |
|
- |
29(clearance, creepage distances and solid insulation) |
- |
- |
|
- |
28(Screw test and connections) |
- |
- |
|
- |
27(Provision for earthing) |
- |
- |
|
- |
26(Terminals for external conductors) |
- |
- |
|
- |
25(Supply connection and external flexible cords) |
- |
- |
|
- |
24(Components) |
- |
- |
|
- |
23(Internal wiring) |
- |
- |
|
- |
22(Construction) |
- |
- |
|
- |
21(Mechanical Strength) |
- |
- |
|
- |
20(Stability and mechanical hazards) |
- |
- |
|
- |
19(Abnormal Operation) |
- |
- |
|
- |
18(Endurance) |
- |
- |
|
- |
17(Over Load Protection of Transformers and associated circuits) |
- |
- |
|
- |
16.3(Electric Strength (after clause 15 and 16.2)) |
- |
- |
|
- |
16.2(Leakage Current (after Clause 15)) |
- |
- |
|
- |
16.1(General) |
- |
- |
|
- |
16.0(General) |
- |
- |
|
- |
15.3(Humidity Test) |
- |
- |
|
- |
15.2(Spillage Test) |
- |
- |
|
- |
15.1(Ingress Protection test other than IPX0 (IP test)) |
- |
- |
|
- |
15.0(Moisture resistance) |
- |
- |
|
- |
14(Transient Over Voltages) |
- |
- |
|
- |
13.3(Electric Strength at operating temperature) |
- |
- |
|
- |
13.2(Leakage current at operating temperature) |
- |
- |
|
- |
13(Leakage current and electric strength at operating temperature) |
- |
- |
|
- |
11.3(Heating) |
- |
- |
|
- |
11.2(General) |
- |
- |
|
- |
11.1(General) |
- |
- |
|
- |
10.2(Current input) |
- |
- |
|
- |
10.1(Power input) |
- |
- |
|
- |
9(Starting of motor operation test requirements and tests) |
- |
- |
|
- |
8.1.4(Protection against live parts against protective impedance) |
- |
- |
|
- |
8.1.3(Protection against live parts in visible glowing heating elements) |
- |
- |
|
- |
8.1.2(Protection against live parts in openings) |
- |
- |
|
- |
8.1.1(Protection against live parts in all positions) |
- |
- |
|
- |
7(Marking and instructions) |
- |
- |
|
- |
A.2(Earth continuity test) |
- |
- |
|
- |
Annex C(Ageing test on motors) |
- |
- |
|
- |
Annex D(Thermal motor protectors) |
- |
- |
|
- |
15.2(Moisture resistance) |
- |
- |
|
- |
19.17(Abnormal operation) |
- |
- |
|
- |
20.1(Stability and mechanical hazards) |
- |
- |
|
- |
21.2(Mechanical strength) |
- |
- |
|
- |
21.3(Mechanical strength) |
- |
- |
|
- |
22.5(Construction) |
- |
- |
|
- |
22.6(Construction) |
- |
- |
|
- |
22.11(Construction) |
- |
- |
|
- |
22.16(Construction) |
- |
- |
|
- |
22.32(Construction) |
- |
- |
|
- |
22.42(Construction) |
- |
- |
|
- |
23.3(Internal wiring) |
- |
- |
|
- |
25(Supply connection and external flexible cords) |
- |
- |
|
- |
25.7(Supply connection and external flexible cords) |
- |
- |
|
- |
25.14(Supply connection and external flexible cords) |
- |
- |
|
- |
25.15(Supply connection and external flexible cords) |
- |
- |
|
- |
26.5(Terminals for external conductors) |
- |
- |
|
- |
27.5(Provision for earthing) |
- |
- |
|
- |
28.1(Screws and connections) |
- |
- |
|
- |
B.22.1(Construction) |
- |
- |
|
- |
B.22.3(Construction) |
- |
- |
|
- |
B.22.4(Construction) |
- |
- |
|
- |
B.22.5(Construction) |
- |
- |
|
- |
|
Complete
|
|
14 Nov, 2027 |
- Included.w.e.f.16.01.2025
Exclusion
Cl 19.11.4.1 to 19.11.4.7 (EMI/EMC) |
1317 |
SHRI BAJRANG TESTING LABS
| IS 2202 : Part 1 (2023) |
WOODEN FLUSH DOOR SHUTTERS SOLID CORE TYPE SPECIFICATION PART 1 PLYWOOD FACE PANELS Seventh Revision |
All |
-
|
24500 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
9.1(Workmanship & Finish) |
- |
500 |
|
- |
9.2(Workmanship & Finish) |
- |
0 |
|
- |
9.3(Workmanship & Finish) |
- |
0 |
|
- |
11.1(Dimensions - Height) |
- |
300 |
|
- |
11.1(Dimensions - Width) |
- |
200 |
|
- |
11.1(Dimensions - Thickness) |
- |
200 |
|
- |
11.1(Dimensions - Variation in thickness) |
- |
500 |
|
- |
11.1(Dimensions - Squareness) |
- |
300 |
|
- |
11.12(End immersion test) |
- |
2000 |
|
- |
11.13(Knife Test) |
- |
2000 |
|
- |
11.14(Glue Adhesion Test) |
- |
2500 |
|
- |
4(GRADE) |
- |
0 |
|
- |
4(TYPE) |
- |
0 |
|
- |
5(SIZES) |
- |
0 |
|
- |
7.1.1(CONSTRUCTION-Blockboard Core) |
- |
0 |
|
- |
7.1.1(CONSTRUCTION-Blockboard Core) |
- |
0 |
|
- |
7.1.2(CONSTRUCTION-Blockboard Core) |
- |
0 |
|
- |
7.3.2(CONSTRUCTION-Stiles and Rails) |
- |
0 |
|
- |
7.3.2(a)(CONSTRUCTION-Stiles and Rails-Joints) |
- |
0 |
|
- |
7.3.2(b)(CONSTRUCTION-Stiles and Rails-Joints) |
- |
0 |
|
- |
7.3.2(c)(CONSTRUCTION-Stiles and Rails-Joints) |
- |
0 |
|
- |
7.3.3(CONSTRUCTION-Stiles and Rails) |
- |
0 |
|
- |
9.1(WORKMANSHIP AND FINISH) |
- |
0 |
|
- |
9.2(WORKMANSHIP AND FINISH) |
- |
0 |
|
- |
9.3(WORKMANSHIP AND FINISH) |
- |
0 |
|
- |
11.1(Dimensions and Squareness Test) |
- |
500 |
|
- |
11.1(Dimensions and Squareness Test) |
- |
0 |
|
- |
11.1(Dimensions and Squareness Test) |
- |
0 |
|
- |
11.1(Dimensions and Squareness Test) |
- |
0 |
|
- |
11.1(Dimensions and Squareness Test) |
- |
0 |
|
- |
11.2(General Flatness Test) |
- |
1500 |
|
- |
11.2(General Flatness Test) |
- |
0 |
|
- |
11.2(General Flatness Test) |
- |
0 |
|
- |
11.3(Local Planeness Test) |
- |
1500 |
|
- |
11.4(Impact Indentation Test) |
- |
2000 |
|
- |
11.4(Impact Indentation Test) |
- |
0 |
|
- |
11.5(Flexure Test) |
- |
2000 |
|
- |
11.5(Flexure Test) |
- |
0 |
|
- |
11.6(Edge Loading Test) |
- |
1500 |
|
- |
11.6(Edge Loading Test) |
- |
0 |
|
- |
11.6(Edge Loading Test) |
- |
0 |
|
- |
11.6(Edge Loading Test) |
- |
0 |
|
- |
11.7.1(Shock Resistance Test) |
- |
2500 |
|
- |
11.7.2(Shock Resistance Test) |
- |
0 |
|
- |
11.8(Buckling Test) |
- |
2000 |
|
- |
11.8(Buckling Test) |
- |
0 |
|
- |
11.8(Buckling Test) |
- |
0 |
|
- |
11.9.2(Slamming Test) |
- |
1500 |
|
- |
11.9.3(Slamming Test) |
- |
0 |
|
- |
11.10(Misuse Test) |
- |
2500 |
|
- |
11.11(Varying Humidity Test) |
- |
2500 |
|
- |
11.11(Varying Humidity Test) |
- |
0 |
|
- |
11.12(End Immersion Test) |
- |
0 |
|
- |
11.13(Knife Test) |
- |
0 |
|
- |
11.14(Glue Adhesion Test) |
- |
0 |
|
- |
11.15(Screw Withdrawal Resistance Test) |
- |
1500 |
|
- |
11.15(Screw Withdrawal Resistance Test) |
- |
0 |
|
- |
Clause 4.2(grades specified) |
- |
400 |
|
- |
Clause 5(SIZES) |
- |
0 |
|
- |
Clause 6.1.1(species of timber) |
- |
0 |
|
- |
Clause 6.1.2(list of species) |
- |
0 |
|
- |
Clause 6.1.3(moisture content) |
- |
1500 |
|
- |
Clause 6.2.1(Plywood) |
- |
0 |
|
- |
Clause 6.2.2(Decorative plywood) |
- |
0 |
|
- |
Clause 6.3(Cross-Bands) |
- |
0 |
|
- |
Clause 6.4.1(Commercial Face
Veneers) |
- |
0 |
|
- |
Clause 6.4.2(Decorative Face
Veneers) |
- |
0 |
|
- |
Clause 6.6.1(Adhesives) |
- |
0 |
|
- |
Clause 6.7(Particle Board) |
- |
0 |
|
- |
Clause 6.8(Medium density
fibre board) |
- |
0 |
|
- |
Clause 6.9(Alternative Materials) |
- |
0 |
|
- |
Clause 7.1(Blockboard Core) |
- |
0 |
|
- |
Clause 7.2(Particle Board or
Medium Density Fibre) |
- |
0 |
|
- |
Clause 7.3(Stiles and Rails) |
- |
0 |
|
- |
Clause 7.4(Levelling) |
- |
0 |
|
- |
Clause 7.5(Face Panel) |
- |
0 |
|
- |
Clause 7.6(Lipping) |
- |
0 |
|
- |
Clause 7.7(Rebating) |
- |
0 |
|
- |
Clause 7.8(Opening for Glazing) |
- |
0 |
|
- |
Clause 7.9(Venetian) |
- |
0 |
|
- |
Clause 8.1(Locks) |
- |
0 |
|
- |
Clause 9(WORKMANSHIP AND
FINISH) |
- |
0 |
|
- |
Clause 10.1(Classification of Tests) |
- |
0 |
|
- |
Clause 11.1(Dimensions and
Squareness Test) |
- |
0 |
|
- |
Clause 11.2(General Flatness Test) |
- |
0 |
|
- |
Clause 11.3(Local Planeness Test) |
- |
0 |
|
- |
Clause 11.4(Impact Indentation Test) |
- |
0 |
|
- |
Clause 11.5(Flexure Test) |
- |
0 |
|
- |
Clause 11.6(Edge Loading Test) |
- |
0 |
|
- |
Clause 11.7(Shock Resistance Test) |
- |
0 |
|
- |
Clause 11.8(Buckling Resistance Test) |
- |
0 |
|
- |
Clause 11.9(Slamming Test) |
- |
0 |
|
- |
Clause 11.10(Misuse Test) |
- |
0 |
|
- |
Clause 11.11(Varying Humidity Test) |
- |
0 |
|
- |
Clause 11.12(End Immersion Test) |
- |
0 |
|
- |
Clause 11.13(Knife Test) |
- |
0 |
|
- |
Clause 11.14(Glue Adhesion Test) |
- |
0 |
|
- |
Clause 11.15(Screw Withdrawal
Resistance Test) |
- |
0 |
|
- |
Clause 12(SAMPLING AND CRITERIA
FOR CONFORMITY) |
- |
0 |
|
- |
Clause 13(ADDITIONAL REQUIREMENTS
FOR ECO MARK) |
- |
0 |
|
- |
Clause 14(Marking) |
- |
0 |
|
- |
4(Grade, Type and Construction) |
- |
0 |
|
- |
5(Sizes and Thickness) |
- |
0 |
|
- |
6.1(Timber) |
- |
0 |
|
- |
6.2(Plywood for flush door shutter) |
- |
0 |
|
- |
6.3(Cross-Bands ) |
- |
0 |
|
- |
6.4.1(Commercial Face Veneers) |
- |
0 |
|
- |
6.4.2(Decorative face veneers) |
- |
0 |
|
- |
6.6(Adhesives) |
- |
0 |
|
- |
6.7(Particle Board) |
- |
0 |
|
- |
6.8(Medium Density Fibre) |
- |
0 |
|
- |
6.9(Alternative Materials) |
- |
0 |
|
- |
7(Construction) |
- |
0 |
|
- |
8.1(Locks) |
- |
0 |
|
- |
8.2(Other Fittings) |
- |
0 |
|
- |
9(Workmanship and Finish) |
- |
0 |
|
- |
10(Tests) |
- |
0 |
|
- |
11.1(Dimensions and Squareness Test) |
- |
0 |
|
- |
11.2(General Flatness Test) |
- |
0 |
|
- |
11.3(Local Planeness Test) |
- |
0 |
|
- |
11.4(Impact Indentation Test) |
- |
0 |
|
- |
11.5(Flexure Test) |
- |
0 |
|
- |
11.6(Edge Loading Test) |
- |
0 |
|
- |
11.7(Shock Resistance Test) |
- |
0 |
|
- |
11.8(Buckling Resistance Test) |
- |
0 |
|
- |
11.9(Slamming Test) |
- |
0 |
|
- |
11.1(Misuse Test) |
- |
0 |
|
- |
11.11(Varying Humidity Test) |
- |
0 |
|
- |
11.12(End Immersion Test) |
- |
0 |
|
- |
11.13(Knife Test) |
- |
0 |
|
- |
11.14(Glue Adhesion Test) |
- |
0 |
|
- |
11.15(Screw Withdrawal Resistance Test) |
- |
0 |
|
- |
14(Marking ) |
- |
0 |
|
- |
Cl-13(ADDITIONAL REQUIREMENTS FOR ECO
MARK) |
- |
0 |
|
- |
9.1(Workmanship & Finish) |
- |
0 |
|
- |
9.2(Workmanship & Finish) |
- |
0 |
|
- |
9.3(Workmanship & Finish) |
- |
0 |
|
- |
11.1(Dimensions - Height) |
- |
0 |
|
- |
11.1(Dimensions - Width) |
- |
0 |
|
- |
11.1(Dimensions - Thickness) |
- |
0 |
|
- |
11.1(Dimensions - Variation in thickness) |
- |
0 |
|
- |
11.1(Dimensions - Squareness) |
- |
0 |
|
- |
11.12(End immersion test) |
- |
0 |
|
- |
11.13(Knife Test) |
- |
0 |
|
- |
11.14(Glue Adhesion Test) |
- |
0 |
|
- |
4(GRADE) |
- |
0 |
|
- |
4(TYPE) |
- |
0 |
|
- |
5(SIZES) |
- |
0 |
|
- |
7.1.1(CONSTRUCTION-Blockboard Core) |
- |
0 |
|
- |
7.1.1(CONSTRUCTION-Blockboard Core) |
- |
0 |
|
- |
7.1.2(CONSTRUCTION-Blockboard Core) |
- |
0 |
|
- |
7.3.2(CONSTRUCTION-Stiles and Rails) |
- |
0 |
|
- |
7.3.2(a)(CONSTRUCTION-Stiles and Rails-Joints) |
- |
0 |
|
- |
7.3.2(b)(CONSTRUCTION-Stiles and Rails-Joints) |
- |
0 |
|
- |
7.3.2(c)(CONSTRUCTION-Stiles and Rails-Joints) |
- |
0 |
|
- |
7.3.3(CONSTRUCTION-Stiles and Rails) |
- |
0 |
|
- |
9.1(WORKMANSHIP AND FINISH) |
- |
0 |
|
- |
9.2(WORKMANSHIP AND FINISH) |
- |
0 |
|
- |
9.3(WORKMANSHIP AND FINISH) |
- |
0 |
|
- |
11.1(Dimensions and Squareness Test) |
- |
0 |
|
- |
11.1(Dimensions and Squareness Test) |
- |
0 |
|
- |
11.1(Dimensions and Squareness Test) |
- |
0 |
|
- |
11.1(Dimensions and Squareness Test) |
- |
0 |
|
- |
11.1(Dimensions and Squareness Test) |
- |
0 |
|
- |
11.2(General Flatness Test) |
- |
0 |
|
- |
11.2(General Flatness Test) |
- |
0 |
|
- |
11.2(General Flatness Test) |
- |
0 |
|
- |
11.3(Local Planeness Test) |
- |
0 |
|
- |
11.4(Impact Indentation Test) |
- |
0 |
|
- |
11.4(Impact Indentation Test) |
- |
0 |
|
- |
11.5(Flexure Test) |
- |
0 |
|
- |
11.5(Flexure Test) |
- |
0 |
|
- |
11.6(Edge Loading Test) |
- |
0 |
|
- |
11.6(Edge Loading Test) |
- |
0 |
|
- |
11.6(Edge Loading Test) |
- |
0 |
|
- |
11.6(Edge Loading Test) |
- |
0 |
|
- |
11.7.1(Shock Resistance Test) |
- |
0 |
|
- |
11.7.2(Shock Resistance Test) |
- |
0 |
|
- |
11.8(Buckling Test) |
- |
0 |
|
- |
11.8(Buckling Test) |
- |
0 |
|
- |
11.8(Buckling Test) |
- |
0 |
|
- |
11.9.2(Slamming Test) |
- |
0 |
|
- |
11.9.3(Slamming Test) |
- |
0 |
|
- |
11.10(Misuse Test) |
- |
0 |
|
- |
11.11(Varying Humidity Test) |
- |
0 |
|
- |
11.11(Varying Humidity Test) |
- |
0 |
|
- |
11.12(End Immersion Test) |
- |
0 |
|
- |
11.13(Knife Test) |
- |
0 |
|
- |
11.14(Glue Adhesion Test) |
- |
0 |
|
- |
11.15(Screw Withdrawal Resistance Test) |
- |
0 |
|
- |
11.15(Screw Withdrawal Resistance Test) |
- |
0 |
|
- |
Clause 4.2(grades specified) |
- |
0 |
|
- |
Clause 5(SIZES) |
- |
0 |
|
- |
Clause 6.1.1(species of timber) |
- |
0 |
|
- |
Clause 6.1.2(list of species) |
- |
0 |
|
- |
Clause 6.1.3(moisture content) |
- |
0 |
|
- |
Clause 6.2.1(Plywood) |
- |
0 |
|
- |
Clause 6.2.2(Decorative plywood) |
- |
0 |
|
- |
Clause 6.3(Cross-Bands) |
- |
0 |
|
- |
Clause 6.4.1(Commercial Face
Veneers) |
- |
0 |
|
- |
Clause 6.4.2(Decorative Face
Veneers) |
- |
0 |
|
- |
Clause 6.6.1(Adhesives) |
- |
0 |
|
- |
Clause 6.7(Particle Board) |
- |
0 |
|
- |
Clause 6.8(Medium density
fibre board) |
- |
0 |
|
- |
Clause 6.9(Alternative Materials) |
- |
0 |
|
- |
Clause 7.1(Blockboard Core) |
- |
0 |
|
- |
Clause 7.2(Particle Board or
Medium Density Fibre) |
- |
0 |
|
- |
Clause 7.3(Stiles and Rails) |
- |
0 |
|
- |
Clause 7.4(Levelling) |
- |
0 |
|
- |
Clause 7.5(Face Panel) |
- |
0 |
|
- |
Clause 7.6(Lipping) |
- |
0 |
|
- |
Clause 7.7(Rebating) |
- |
0 |
|
- |
Clause 7.8(Opening for Glazing) |
- |
0 |
|
- |
Clause 7.9(Venetian) |
- |
0 |
|
- |
Clause 8.1(Locks) |
- |
0 |
|
- |
Clause 9(WORKMANSHIP AND
FINISH) |
- |
0 |
|
- |
Clause 10.1(Classification of Tests) |
- |
0 |
|
- |
Clause 11.1(Dimensions and
Squareness Test) |
- |
0 |
|
- |
Clause 11.2(General Flatness Test) |
- |
0 |
|
- |
Clause 11.3(Local Planeness Test) |
- |
0 |
|
- |
Clause 11.4(Impact Indentation Test) |
- |
0 |
|
- |
Clause 11.5(Flexure Test) |
- |
0 |
|
- |
Clause 11.6(Edge Loading Test) |
- |
0 |
|
- |
Clause 11.7(Shock Resistance Test) |
- |
0 |
|
- |
Clause 11.8(Buckling Resistance Test) |
- |
0 |
|
- |
Clause 11.9(Slamming Test) |
- |
0 |
|
- |
Clause 11.10(Misuse Test) |
- |
0 |
|
- |
Clause 11.11(Varying Humidity Test) |
- |
0 |
|
- |
Clause 11.12(End Immersion Test) |
- |
0 |
|
- |
Clause 11.13(Knife Test) |
- |
0 |
|
- |
Clause 11.14(Glue Adhesion Test) |
- |
0 |
|
- |
Clause 11.15(Screw Withdrawal
Resistance Test) |
- |
0 |
|
- |
Clause 12(SAMPLING AND CRITERIA
FOR CONFORMITY) |
- |
0 |
|
- |
Clause 13(ADDITIONAL REQUIREMENTS
FOR ECO MARK) |
- |
0 |
|
- |
Clause 14(Marking) |
- |
0 |
|
- |
4(Grade, Type and Construction) |
- |
0 |
|
- |
5(Sizes and Thickness) |
- |
0 |
|
- |
6.1(Timber) |
- |
0 |
|
- |
6.2(Plywood for flush door shutter) |
- |
0 |
|
- |
6.3(Cross-Bands ) |
- |
0 |
|
- |
6.4.1(Commercial Face Veneers) |
- |
0 |
|
- |
6.4.2(Decorative face veneers) |
- |
0 |
|
- |
6.6(Adhesives) |
- |
0 |
|
- |
6.7(Particle Board) |
- |
0 |
|
- |
6.8(Medium Density Fibre) |
- |
0 |
|
- |
6.9(Alternative Materials) |
- |
0 |
|
- |
7(Construction) |
- |
0 |
|
- |
8.1(Locks) |
- |
0 |
|
- |
8.2(Other Fittings) |
- |
0 |
|
- |
9(Workmanship and Finish) |
- |
0 |
|
- |
10(Tests) |
- |
0 |
|
- |
11.1(Dimensions and Squareness Test) |
- |
0 |
|
- |
11.2(General Flatness Test) |
- |
0 |
|
- |
11.3(Local Planeness Test) |
- |
0 |
|
- |
11.4(Impact Indentation Test) |
- |
0 |
|
- |
11.5(Flexure Test) |
- |
0 |
|
- |
11.6(Edge Loading Test) |
- |
0 |
|
- |
11.7(Shock Resistance Test) |
- |
0 |
|
- |
11.8(Buckling Resistance Test) |
- |
0 |
|
- |
11.9(Slamming Test) |
- |
0 |
|
- |
11.1(Misuse Test) |
- |
0 |
|
- |
11.11(Varying Humidity Test) |
- |
0 |
|
- |
11.12(End Immersion Test) |
- |
0 |
|
- |
11.13(Knife Test) |
- |
0 |
|
- |
11.14(Glue Adhesion Test) |
- |
0 |
|
- |
11.15(Screw Withdrawal Resistance Test) |
- |
0 |
|
- |
14(Marking ) |
- |
0 |
|
- |
Cl-13(ADDITIONAL REQUIREMENTS FOR ECO
MARK) |
- |
0 |
|
- |
9.1(Workmanship & Finish) |
- |
0 |
|
- |
9.2(Workmanship & Finish) |
- |
0 |
|
- |
9.3(Workmanship & Finish) |
- |
0 |
|
- |
11.1(Dimensions - Height) |
- |
0 |
|
- |
11.1(Dimensions - Width) |
- |
0 |
|
- |
11.1(Dimensions - Thickness) |
- |
0 |
|
- |
11.1(Dimensions - Variation in thickness) |
- |
0 |
|
- |
11.1(Dimensions - Squareness) |
- |
0 |
|
- |
11.12(End immersion test) |
- |
0 |
|
- |
11.13(Knife Test) |
- |
0 |
|
- |
11.14(Glue Adhesion Test) |
- |
0 |
|
- |
4(GRADE) |
- |
0 |
|
- |
4(TYPE) |
- |
0 |
|
- |
5(SIZES) |
- |
0 |
|
- |
7.1.1(CONSTRUCTION-Blockboard Core) |
- |
0 |
|
- |
7.1.1(CONSTRUCTION-Blockboard Core) |
- |
0 |
|
- |
7.1.2(CONSTRUCTION-Blockboard Core) |
- |
0 |
|
- |
7.3.2(CONSTRUCTION-Stiles and Rails) |
- |
0 |
|
- |
7.3.2(a)(CONSTRUCTION-Stiles and Rails-Joints) |
- |
0 |
|
- |
7.3.2(b)(CONSTRUCTION-Stiles and Rails-Joints) |
- |
0 |
|
- |
7.3.2(c)(CONSTRUCTION-Stiles and Rails-Joints) |
- |
0 |
|
- |
7.3.3(CONSTRUCTION-Stiles and Rails) |
- |
0 |
|
- |
9.1(WORKMANSHIP AND FINISH) |
- |
0 |
|
- |
9.2(WORKMANSHIP AND FINISH) |
- |
0 |
|
- |
9.3(WORKMANSHIP AND FINISH) |
- |
0 |
|
- |
11.1(Dimensions and Squareness Test) |
- |
0 |
|
- |
11.1(Dimensions and Squareness Test) |
- |
0 |
|
- |
11.1(Dimensions and Squareness Test) |
- |
0 |
|
- |
11.1(Dimensions and Squareness Test) |
- |
0 |
|
- |
11.1(Dimensions and Squareness Test) |
- |
0 |
|
- |
11.2(General Flatness Test) |
- |
0 |
|
- |
11.2(General Flatness Test) |
- |
0 |
|
- |
11.2(General Flatness Test) |
- |
0 |
|
- |
11.3(Local Planeness Test) |
- |
0 |
|
- |
11.4(Impact Indentation Test) |
- |
0 |
|
- |
11.4(Impact Indentation Test) |
- |
0 |
|
- |
11.5(Flexure Test) |
- |
0 |
|
- |
11.5(Flexure Test) |
- |
0 |
|
- |
11.6(Edge Loading Test) |
- |
0 |
|
- |
11.6(Edge Loading Test) |
- |
0 |
|
- |
11.6(Edge Loading Test) |
- |
0 |
|
- |
11.6(Edge Loading Test) |
- |
0 |
|
- |
11.7.1(Shock Resistance Test) |
- |
0 |
|
- |
11.7.2(Shock Resistance Test) |
- |
0 |
|
- |
11.8(Buckling Test) |
- |
0 |
|
- |
11.8(Buckling Test) |
- |
0 |
|
- |
11.8(Buckling Test) |
- |
0 |
|
- |
11.9.2(Slamming Test) |
- |
0 |
|
- |
11.9.3(Slamming Test) |
- |
0 |
|
- |
11.10(Misuse Test) |
- |
0 |
|
- |
11.11(Varying Humidity Test) |
- |
0 |
|
- |
11.11(Varying Humidity Test) |
- |
0 |
|
- |
11.12(End Immersion Test) |
- |
0 |
|
- |
11.13(Knife Test) |
- |
0 |
|
- |
11.14(Glue Adhesion Test) |
- |
0 |
|
- |
11.15(Screw Withdrawal Resistance Test) |
- |
0 |
|
- |
11.15(Screw Withdrawal Resistance Test) |
- |
0 |
|
- |
Clause 4.2(grades specified) |
- |
0 |
|
- |
Clause 5(SIZES) |
- |
0 |
|
- |
Clause 6.1.1(species of timber) |
- |
0 |
|
- |
Clause 6.1.2(list of species) |
- |
0 |
|
- |
Clause 6.1.3(moisture content) |
- |
0 |
|
- |
Clause 6.2.1(Plywood) |
- |
0 |
|
- |
Clause 6.2.2(Decorative plywood) |
- |
0 |
|
- |
Clause 6.3(Cross-Bands) |
- |
0 |
|
- |
Clause 6.4.1(Commercial Face
Veneers) |
- |
0 |
|
- |
Clause 6.4.2(Decorative Face
Veneers) |
- |
0 |
|
- |
Clause 6.6.1(Adhesives) |
- |
0 |
|
- |
Clause 6.7(Particle Board) |
- |
0 |
|
- |
Clause 6.8(Medium density
fibre board) |
- |
0 |
|
- |
Clause 6.9(Alternative Materials) |
- |
0 |
|
- |
Clause 7.1(Blockboard Core) |
- |
0 |
|
- |
Clause 7.2(Particle Board or
Medium Density Fibre) |
- |
0 |
|
- |
Clause 7.3(Stiles and Rails) |
- |
0 |
|
- |
Clause 7.4(Levelling) |
- |
0 |
|
- |
Clause 7.5(Face Panel) |
- |
0 |
|
- |
Clause 7.6(Lipping) |
- |
0 |
|
- |
Clause 7.7(Rebating) |
- |
0 |
|
- |
Clause 7.8(Opening for Glazing) |
- |
0 |
|
- |
Clause 7.9(Venetian) |
- |
0 |
|
- |
Clause 8.1(Locks) |
- |
0 |
|
- |
Clause 9(WORKMANSHIP AND
FINISH) |
- |
0 |
|
- |
Clause 10.1(Classification of Tests) |
- |
0 |
|
- |
Clause 11.1(Dimensions and
Squareness Test) |
- |
0 |
|
- |
Clause 11.2(General Flatness Test) |
- |
0 |
|
- |
Clause 11.3(Local Planeness Test) |
- |
0 |
|
- |
Clause 11.4(Impact Indentation Test) |
- |
0 |
|
- |
Clause 11.5(Flexure Test) |
- |
0 |
|
- |
Clause 11.6(Edge Loading Test) |
- |
0 |
|
- |
Clause 11.7(Shock Resistance Test) |
- |
0 |
|
- |
Clause 11.8(Buckling Resistance Test) |
- |
0 |
|
- |
Clause 11.9(Slamming Test) |
- |
0 |
|
- |
Clause 11.10(Misuse Test) |
- |
0 |
|
- |
Clause 11.11(Varying Humidity Test) |
- |
0 |
|
- |
Clause 11.12(End Immersion Test) |
- |
0 |
|
- |
Clause 11.13(Knife Test) |
- |
0 |
|
- |
Clause 11.14(Glue Adhesion Test) |
- |
0 |
|
- |
Clause 11.15(Screw Withdrawal
Resistance Test) |
- |
0 |
|
- |
Clause 12(SAMPLING AND CRITERIA
FOR CONFORMITY) |
- |
0 |
|
- |
Clause 13(ADDITIONAL REQUIREMENTS
FOR ECO MARK) |
- |
0 |
|
- |
Clause 14(Marking) |
- |
0 |
|
- |
4(Grade, Type and Construction) |
- |
0 |
|
- |
5(Sizes and Thickness) |
- |
0 |
|
- |
6.1(Timber) |
- |
0 |
|
- |
6.2(Plywood for flush door shutter) |
- |
0 |
|
- |
6.3(Cross-Bands ) |
- |
0 |
|
- |
6.4.1(Commercial Face Veneers) |
- |
0 |
|
- |
6.4.2(Decorative face veneers) |
- |
0 |
|
- |
6.6(Adhesives) |
- |
0 |
|
- |
6.7(Particle Board) |
- |
0 |
|
- |
6.8(Medium Density Fibre) |
- |
0 |
|
- |
6.9(Alternative Materials) |
- |
0 |
|
- |
7(Construction) |
- |
0 |
|
- |
8.1(Locks) |
- |
0 |
|
- |
8.2(Other Fittings) |
- |
0 |
|
- |
9(Workmanship and Finish) |
- |
0 |
|
- |
10(Tests) |
- |
0 |
|
- |
11.1(Dimensions and Squareness Test) |
- |
0 |
|
- |
11.2(General Flatness Test) |
- |
0 |
|
- |
11.3(Local Planeness Test) |
- |
0 |
|
- |
11.4(Impact Indentation Test) |
- |
0 |
|
- |
11.5(Flexure Test) |
- |
0 |
|
- |
11.6(Edge Loading Test) |
- |
0 |
|
- |
11.7(Shock Resistance Test) |
- |
0 |
|
- |
11.8(Buckling Resistance Test) |
- |
0 |
|
- |
11.9(Slamming Test) |
- |
0 |
|
- |
11.1(Misuse Test) |
- |
0 |
|
- |
11.11(Varying Humidity Test) |
- |
0 |
|
- |
11.12(End Immersion Test) |
- |
0 |
|
- |
11.13(Knife Test) |
- |
0 |
|
- |
11.14(Glue Adhesion Test) |
- |
0 |
|
- |
11.15(Screw Withdrawal Resistance Test) |
- |
0 |
|
- |
14(Marking ) |
- |
0 |
|
- |
Cl-13(ADDITIONAL REQUIREMENTS FOR ECO
MARK) |
- |
0 |
|
- |
|
Complete
|
|
01 Dec, 2027 |
- Included w.e.f 20.03.2025
Size restricted upto 2100 mm |
1318 |
Shri Krishna Test House
| IS 17569 (2021) |
Insulated Containers for Food Storage — Specification |
all types |
-
|
30000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
5(Manufacture and Workmanship) |
- |
30000 |
|
- |
5.3(Manufacture and Workmanship) |
- |
30000 |
|
- |
7.1(Material) |
- |
30000 |
|
- |
7.1.2(Thickness) |
- |
30000 |
|
- |
7.1.2.1(Requirements and Tests(Material) – Outer Protective Case and Accessories – Lead) |
- |
30000 |
|
- |
7.1.2.1(Requirements and Tests(Material) – Outer Protective Case and Accessories – Cadmium) |
- |
30000 |
|
- |
7.1.2.8(Bisphenol A(BPA)) |
- |
30000 |
|
- |
7.3(Capacity) |
- |
30000 |
|
- |
7.4(Heat Retention Capability) |
- |
30000 |
|
- |
7.5(Cold Retention Capability) |
- |
30000 |
|
- |
7.6.1(Drop Impact Test) |
- |
30000 |
|
- |
7.6.2(Pendulum Impact Test) |
- |
30000 |
|
- |
7.7(Fixing Strength of the Handle) |
- |
30000 |
|
- |
7.8(Test for Strength of Shoulder Strap) |
- |
30000 |
|
- |
7.9(Leakage Test) |
- |
30000 |
|
- |
7.10(Joint Leak Test) |
- |
30000 |
|
- |
7.11(Staining Test) |
- |
30000 |
|
- |
7.12("Check for PUF (Polyurethane Foam) or any
Other Similar Thermal Insulation Material
") |
- |
30000 |
|
- |
7.13.1(Length of the Shoulder Strap) |
- |
30000 |
|
- |
7.13.2(Stability of Insulated Container) |
- |
30000 |
|
- |
7.13.3(Cleaning) |
- |
30000 |
|
- |
7.14(Seepage Test) |
- |
30000 |
|
- |
9.1(Marking) |
- |
30000 |
|
- |
9.2(BIS certification marking) |
- |
30000 |
|
- |
10(Packaging) |
- |
30000 |
|
- |
CLAUSE 5.2(Welding Defects) |
- |
30000 |
|
- |
CLAUSE 7.1(Materials) |
- |
30000 |
|
- |
CLAUSE 7.1.2.2(Thickness of plastic) |
- |
30000 |
|
- |
"CLAUSE 7.1.2.1 "(Minimum Thickness of Outer Container) |
- |
30000 |
|
- |
"CLAUSE 7.1.2.1 "(Coating Thickness) |
- |
30000 |
|
- |
"CLAUSE 7.1.2.1 "(Salt Water Corrosion Test) |
- |
30000 |
|
- |
CLAUSE 7.1.2.1(Adhesion Test) |
- |
30000 |
|
- |
CLAUSE 7.1.2.1(Lead Limit) |
- |
30000 |
|
- |
CLAUSE 7.1.2.1(Cadmium Limit) |
- |
30000 |
|
- |
CLAUSE 7.1.2.3(Outer container or lid - thickness) |
- |
30000 |
|
- |
CLAUSE 7.3(Capacity) |
- |
30000 |
|
- |
CLAUSE 7.4(Heat Retention Capability) |
- |
30000 |
|
- |
CLAUSE 7.5(Cold Retention Capability) |
- |
30000 |
|
- |
CLAUSE 7.6.1(Drop Impact) |
- |
30000 |
|
- |
CLAUSE 7.6.2(Pendulum Impact) |
- |
30000 |
|
- |
CLAUSE 7.7(Fixing Strength of Handle) |
- |
30000 |
|
- |
CLAUSE 7.8(Test for Strength of Shoulder Strap) |
- |
30000 |
|
- |
CLAUSE 7.9(Leakage Test) |
- |
30000 |
|
- |
CLAUSE 7.10(Joint Leak Test) |
- |
30000 |
|
- |
CLAUSE 7.11(Staining Test) |
- |
30000 |
|
- |
CLAUSE 7.12(Checking of PUF insulation) |
- |
30000 |
|
- |
CLAUSE 7.13.1(Length of the Shoulder Strap) |
- |
30000 |
|
- |
CLAUSE 7.13.2(Stability of Flask) |
- |
30000 |
|
- |
CLAUSE 7.1.1(Material - inner container) |
- |
30000 |
|
- |
C 7.1.1 Note Annex C(Test for leaching of food grade stainless steel) |
- |
30000 |
|
- |
CL 7.1.1 Note- Annex D(Sensational test method) |
- |
30000 |
|
- |
Cl 7.1.2.2(Polymer - test for BPA) |
- |
30000 |
|
- |
Cl 7.1.2.4(Silicon gasket - overall migration) |
- |
30000 |
|
- |
Cl 7.1.2.4(Silicon gasket - defects) |
- |
30000 |
|
- |
Cl 7.1.2.5(Performance requirement for glass lid - Fragmentation test (Cl 8.15.1 of IS 2347)) |
- |
30000 |
|
- |
Cl 7.1.2.5(Performance requirement for glass lid - Ball drop test (Cl 8.15.2 of IS 2347)) |
- |
30000 |
|
- |
Cl 7.1.2.5(Performance requirement for glass lid - Thermal shock test (Cl 8.15.3 of IS 2347)) |
- |
30000 |
|
- |
Cl 7.1.2.5(Performance requirement for glass lid - Free fall test (Cl 8.15.4 of IS 2347)) |
- |
30000 |
|
- |
Cl 7.1.2.5(Thickness of steel rim) |
- |
30000 |
|
- |
Cl 7.1.2.5(Thickness of glass lid) |
- |
30000 |
|
- |
Cl 7.1.2.6(Thermal insulating material) |
- |
30000 |
|
- |
Cl 7.1.2.7(Additional lid) |
- |
30000 |
|
- |
Cl 7.1.2.8(Hot/Cold Box - thickness) |
- |
30000 |
|
- |
Cl 7.1.2.9(Internal utensils- material) |
- |
30000 |
|
- |
Cl 7.1.2.9(Internal utensils- thickness) |
- |
30000 |
|
- |
Cl 7.1.2.9(Internal utensils - thickness of plastic lid) |
- |
30000 |
|
- |
Cl 7.1.2.9(Test for BPA) |
- |
30000 |
|
- |
CLAUSE 7.1.2.3(Outer container or lid - material) |
- |
30000 |
|
- |
5(Manufacture and Workmanship) |
- |
30000 |
|
- |
5.3(Manufacture and Workmanship) |
- |
30000 |
|
- |
7.1(Material) |
- |
30000 |
|
- |
7.1.2(Thickness) |
- |
30000 |
|
- |
7.1.2.1(Requirements and Tests(Material) – Outer Protective Case and Accessories – Lead) |
- |
30000 |
|
- |
7.1.2.1(Requirements and Tests(Material) – Outer Protective Case and Accessories – Cadmium) |
- |
30000 |
|
- |
7.1.2.8(Bisphenol A(BPA)) |
- |
30000 |
|
- |
7.3(Capacity) |
- |
30000 |
|
- |
7.4(Heat Retention Capability) |
- |
30000 |
|
- |
7.5(Cold Retention Capability) |
- |
30000 |
|
- |
7.6.1(Drop Impact Test) |
- |
30000 |
|
- |
7.6.2(Pendulum Impact Test) |
- |
30000 |
|
- |
7.7(Fixing Strength of the Handle) |
- |
30000 |
|
- |
7.8(Test for Strength of Shoulder Strap) |
- |
30000 |
|
- |
7.9(Leakage Test) |
- |
30000 |
|
- |
7.10(Joint Leak Test) |
- |
30000 |
|
- |
7.11(Staining Test) |
- |
30000 |
|
- |
7.12("Check for PUF (Polyurethane Foam) or any
Other Similar Thermal Insulation Material
") |
- |
30000 |
|
- |
7.13.1(Length of the Shoulder Strap) |
- |
30000 |
|
- |
7.13.2(Stability of Insulated Container) |
- |
30000 |
|
- |
7.13.3(Cleaning) |
- |
30000 |
|
- |
7.14(Seepage Test) |
- |
30000 |
|
- |
9.1(Marking) |
- |
30000 |
|
- |
9.2(BIS certification marking) |
- |
30000 |
|
- |
10(Packaging) |
- |
30000 |
|
- |
CLAUSE 5.2(Welding Defects) |
- |
30000 |
|
- |
CLAUSE 7.1(Materials) |
- |
30000 |
|
- |
CLAUSE 7.1.2.2(Thickness of plastic) |
- |
30000 |
|
- |
"CLAUSE 7.1.2.1 "(Minimum Thickness of Outer Container) |
- |
30000 |
|
- |
"CLAUSE 7.1.2.1 "(Coating Thickness) |
- |
30000 |
|
- |
"CLAUSE 7.1.2.1 "(Salt Water Corrosion Test) |
- |
30000 |
|
- |
CLAUSE 7.1.2.1(Adhesion Test) |
- |
30000 |
|
- |
CLAUSE 7.1.2.1(Lead Limit) |
- |
30000 |
|
- |
CLAUSE 7.1.2.1(Cadmium Limit) |
- |
30000 |
|
- |
CLAUSE 7.1.2.3(Outer container or lid - thickness) |
- |
30000 |
|
- |
CLAUSE 7.3(Capacity) |
- |
30000 |
|
- |
CLAUSE 7.4(Heat Retention Capability) |
- |
30000 |
|
- |
CLAUSE 7.5(Cold Retention Capability) |
- |
30000 |
|
- |
CLAUSE 7.6.1(Drop Impact) |
- |
30000 |
|
- |
CLAUSE 7.6.2(Pendulum Impact) |
- |
30000 |
|
- |
CLAUSE 7.7(Fixing Strength of Handle) |
- |
30000 |
|
- |
CLAUSE 7.8(Test for Strength of Shoulder Strap) |
- |
30000 |
|
- |
CLAUSE 7.9(Leakage Test) |
- |
30000 |
|
- |
CLAUSE 7.10(Joint Leak Test) |
- |
30000 |
|
- |
CLAUSE 7.11(Staining Test) |
- |
30000 |
|
- |
CLAUSE 7.12(Checking of PUF insulation) |
- |
30000 |
|
- |
CLAUSE 7.13.1(Length of the Shoulder Strap) |
- |
30000 |
|
- |
CLAUSE 7.13.2(Stability of Flask) |
- |
30000 |
|
- |
CLAUSE 7.1.1(Material - inner container) |
- |
30000 |
|
- |
C 7.1.1 Note Annex C(Test for leaching of food grade stainless steel) |
- |
30000 |
|
- |
CL 7.1.1 Note- Annex D(Sensational test method) |
- |
30000 |
|
- |
Cl 7.1.2.2(Polymer - test for BPA) |
- |
30000 |
|
- |
Cl 7.1.2.4(Silicon gasket - overall migration) |
- |
30000 |
|
- |
Cl 7.1.2.4(Silicon gasket - defects) |
- |
30000 |
|
- |
Cl 7.1.2.5(Performance requirement for glass lid - Fragmentation test (Cl 8.15.1 of IS 2347)) |
- |
30000 |
|
- |
Cl 7.1.2.5(Performance requirement for glass lid - Ball drop test (Cl 8.15.2 of IS 2347)) |
- |
30000 |
|
- |
Cl 7.1.2.5(Performance requirement for glass lid - Thermal shock test (Cl 8.15.3 of IS 2347)) |
- |
30000 |
|
- |
Cl 7.1.2.5(Performance requirement for glass lid - Free fall test (Cl 8.15.4 of IS 2347)) |
- |
30000 |
|
- |
Cl 7.1.2.5(Thickness of steel rim) |
- |
30000 |
|
- |
Cl 7.1.2.5(Thickness of glass lid) |
- |
30000 |
|
- |
Cl 7.1.2.6(Thermal insulating material) |
- |
30000 |
|
- |
Cl 7.1.2.7(Additional lid) |
- |
30000 |
|
- |
Cl 7.1.2.8(Hot/Cold Box - thickness) |
- |
30000 |
|
- |
Cl 7.1.2.9(Internal utensils- material) |
- |
30000 |
|
- |
Cl 7.1.2.9(Internal utensils- thickness) |
- |
30000 |
|
- |
Cl 7.1.2.9(Internal utensils - thickness of plastic lid) |
- |
30000 |
|
- |
Cl 7.1.2.9(Test for BPA) |
- |
30000 |
|
- |
CLAUSE 7.1.2.3(Outer container or lid - material) |
- |
30000 |
|
- |
5(Manufacture and Workmanship) |
- |
30000 |
|
- |
5.3(Manufacture and Workmanship) |
- |
30000 |
|
- |
7.1(Material) |
- |
30000 |
|
- |
7.1.2(Thickness) |
- |
30000 |
|
- |
7.1.2.1(Requirements and Tests(Material) – Outer Protective Case and Accessories – Lead) |
- |
30000 |
|
- |
7.1.2.1(Requirements and Tests(Material) – Outer Protective Case and Accessories – Cadmium) |
- |
30000 |
|
- |
7.1.2.8(Bisphenol A(BPA)) |
- |
30000 |
|
- |
7.3(Capacity) |
- |
30000 |
|
- |
7.4(Heat Retention Capability) |
- |
30000 |
|
- |
7.5(Cold Retention Capability) |
- |
30000 |
|
- |
7.6.1(Drop Impact Test) |
- |
30000 |
|
- |
7.6.2(Pendulum Impact Test) |
- |
30000 |
|
- |
7.7(Fixing Strength of the Handle) |
- |
30000 |
|
- |
7.8(Test for Strength of Shoulder Strap) |
- |
30000 |
|
- |
7.9(Leakage Test) |
- |
30000 |
|
- |
7.10(Joint Leak Test) |
- |
30000 |
|
- |
7.11(Staining Test) |
- |
30000 |
|
- |
7.12("Check for PUF (Polyurethane Foam) or any
Other Similar Thermal Insulation Material
") |
- |
30000 |
|
- |
7.13.1(Length of the Shoulder Strap) |
- |
30000 |
|
- |
7.13.2(Stability of Insulated Container) |
- |
30000 |
|
- |
7.13.3(Cleaning) |
- |
30000 |
|
- |
7.14(Seepage Test) |
- |
30000 |
|
- |
9.1(Marking) |
- |
30000 |
|
- |
9.2(BIS certification marking) |
- |
30000 |
|
- |
10(Packaging) |
- |
30000 |
|
- |
CLAUSE 5.2(Welding Defects) |
- |
30000 |
|
- |
CLAUSE 7.1(Materials) |
- |
30000 |
|
- |
CLAUSE 7.1.2.2(Thickness of plastic) |
- |
30000 |
|
- |
"CLAUSE 7.1.2.1 "(Minimum Thickness of Outer Container) |
- |
30000 |
|
- |
"CLAUSE 7.1.2.1 "(Coating Thickness) |
- |
30000 |
|
- |
"CLAUSE 7.1.2.1 "(Salt Water Corrosion Test) |
- |
30000 |
|
- |
CLAUSE 7.1.2.1(Adhesion Test) |
- |
30000 |
|
- |
CLAUSE 7.1.2.1(Lead Limit) |
- |
30000 |
|
- |
CLAUSE 7.1.2.1(Cadmium Limit) |
- |
30000 |
|
- |
CLAUSE 7.1.2.3(Outer container or lid - thickness) |
- |
30000 |
|
- |
CLAUSE 7.3(Capacity) |
- |
30000 |
|
- |
CLAUSE 7.4(Heat Retention Capability) |
- |
30000 |
|
- |
CLAUSE 7.5(Cold Retention Capability) |
- |
30000 |
|
- |
CLAUSE 7.6.1(Drop Impact) |
- |
30000 |
|
- |
CLAUSE 7.6.2(Pendulum Impact) |
- |
30000 |
|
- |
CLAUSE 7.7(Fixing Strength of Handle) |
- |
30000 |
|
- |
CLAUSE 7.8(Test for Strength of Shoulder Strap) |
- |
30000 |
|
- |
CLAUSE 7.9(Leakage Test) |
- |
30000 |
|
- |
CLAUSE 7.10(Joint Leak Test) |
- |
30000 |
|
- |
CLAUSE 7.11(Staining Test) |
- |
30000 |
|
- |
CLAUSE 7.12(Checking of PUF insulation) |
- |
30000 |
|
- |
CLAUSE 7.13.1(Length of the Shoulder Strap) |
- |
30000 |
|
- |
CLAUSE 7.13.2(Stability of Flask) |
- |
30000 |
|
- |
CLAUSE 7.1.1(Material - inner container) |
- |
30000 |
|
- |
C 7.1.1 Note Annex C(Test for leaching of food grade stainless steel) |
- |
30000 |
|
- |
CL 7.1.1 Note- Annex D(Sensational test method) |
- |
30000 |
|
- |
Cl 7.1.2.2(Polymer - test for BPA) |
- |
30000 |
|
- |
Cl 7.1.2.4(Silicon gasket - overall migration) |
- |
30000 |
|
- |
Cl 7.1.2.4(Silicon gasket - defects) |
- |
30000 |
|
- |
Cl 7.1.2.5(Performance requirement for glass lid - Fragmentation test (Cl 8.15.1 of IS 2347)) |
- |
30000 |
|
- |
Cl 7.1.2.5(Performance requirement for glass lid - Ball drop test (Cl 8.15.2 of IS 2347)) |
- |
30000 |
|
- |
Cl 7.1.2.5(Performance requirement for glass lid - Thermal shock test (Cl 8.15.3 of IS 2347)) |
- |
30000 |
|
- |
Cl 7.1.2.5(Performance requirement for glass lid - Free fall test (Cl 8.15.4 of IS 2347)) |
- |
30000 |
|
- |
Cl 7.1.2.5(Thickness of steel rim) |
- |
30000 |
|
- |
Cl 7.1.2.5(Thickness of glass lid) |
- |
30000 |
|
- |
Cl 7.1.2.6(Thermal insulating material) |
- |
30000 |
|
- |
Cl 7.1.2.7(Additional lid) |
- |
30000 |
|
- |
Cl 7.1.2.8(Hot/Cold Box - thickness) |
- |
30000 |
|
- |
Cl 7.1.2.9(Internal utensils- material) |
- |
30000 |
|
- |
Cl 7.1.2.9(Internal utensils- thickness) |
- |
30000 |
|
- |
Cl 7.1.2.9(Internal utensils - thickness of plastic lid) |
- |
30000 |
|
- |
Cl 7.1.2.9(Test for BPA) |
- |
30000 |
|
- |
CLAUSE 7.1.2.3(Outer container or lid - material) |
- |
30000 |
|
- |
|
Complete
|
|
05 Oct, 2025 |
- Included.w.e.f.22.01.2025 |
1319 |
DELHI TEST HOUSE, Azadhpur
| IS 3589 (2001) |
Steel pipes for water and sewage (168.3 To 2540 Mm Outside Diameter) - Specification (Third Revision) |
- |
-
|
15500 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
8.1 Table 2 Table 3(Carbon Content IS 228) |
- |
500 |
|
Rs. 15500/- FOR SIZE 168.3 - 508 MM
Rs. 35000/- FOR SIZE 508-2540 MM |
8.1 Table 2 Table 3(Manganese Content IS 228) |
- |
500 |
|
Rs. 15500/- FOR SIZE 168.3 - 508 MM
Rs. 35000/- FOR SIZE 508-2540 MM |
8.1 Table 2 Table 3(Phosphorus Content IS 228) |
- |
500 |
|
Rs. 15500/- FOR SIZE 168.3 - 508 MM
Rs. 35000/- FOR SIZE 508-2540 MM |
8.1 Table 2 Table 3(Sulphur Content IS 228) |
- |
500 |
|
Rs. 15500/- FOR SIZE 168.3 - 508 MM
Rs. 35000/- FOR SIZE 508-2540 MM |
9.3(Guided bend test(For SAW Pipes)) |
- |
2500 |
|
Rs. 15500/- FOR SIZE 168.3 - 508 MM
Rs. 35000/- FOR SIZE 508-2540 MM |
11.1, Table 5.(Outside Diameter (OD)) |
- |
500 |
|
Rs. 15500/- FOR SIZE 168.3 - 508 MM
Rs. 35000/- FOR SIZE 508-2540 MM |
11.1, Table 5.(Thickness) |
- |
500 |
|
Rs. 15500/- FOR SIZE 168.3 - 508 MM
Rs. 35000/- FOR SIZE 508-2540 MM |
11.1, Table 5.(Mass) |
- |
500 |
|
Rs. 15500/- FOR SIZE 168.3 - 508 MM
Rs. 35000/- FOR SIZE 508-2540 MM |
14.1(Visual inspection, Appearance and Workmanship) |
- |
250 |
|
Rs. 15500/- FOR SIZE 168.3 - 508 MM
Rs. 35000/- FOR SIZE 508-2540 MM |
14.4(Visual inspection, Appearance and Workmanship-Dent Depth(below 610 mm OD)) |
- |
250 |
|
Rs. 15500/- FOR SIZE 168.3 - 508 MM
Rs. 35000/- FOR SIZE 508-2540 MM |
14.4(Visual inspection, Appearance and Workmanship-Dent Length) |
- |
250 |
|
Rs. 15500/- FOR SIZE 168.3 - 508 MM
Rs. 35000/- FOR SIZE 508-2540 MM |
8.1(CE) |
- |
500 |
|
Rs. 15500/- FOR SIZE 168.3 - 508 MM
Rs. 35000/- FOR SIZE 508-2540 MM |
9.3(Guided Bend Test
(for SAW Pipes)) |
- |
2500 |
|
Rs. 15500/- FOR SIZE 168.3 - 508 MM
Rs. 35000/- FOR SIZE 508-2540 MM |
9.2.3(Flattening Test for
seamless pipes) |
- |
1500 |
|
Rs. 15500/- FOR SIZE 168.3 - 508 MM
Rs. 35000/- FOR SIZE 508-2540 MM |
9.2.1(Flattening test for
ERW pipes ) |
- |
1500 |
|
Rs. 15500/- FOR SIZE 168.3 - 508 MM
Rs. 35000/- FOR SIZE 508-2540 MM |
9.1(Tensile test-Yield Strength) |
- |
1500 |
|
Rs. 15500/- FOR SIZE 168.3 - 508 MM
Rs. 35000/- FOR SIZE 508-2540 MM |
9.1(Tensile test-Strength) |
- |
1500 |
|
Rs. 15500/- FOR SIZE 168.3 - 508 MM
Rs. 35000/- FOR SIZE 508-2540 MM |
9.1(Tensile test- Elongation) |
- |
1500 |
|
Rs. 15500/- FOR SIZE 168.3 - 508 MM
Rs. 35000/- FOR SIZE 508-2540 MM |
8.1(CE) |
- |
500 |
|
Rs. 15500/- FOR SIZE 168.3 - 508 MM
Rs. 35000/- FOR SIZE 508-2540 MM |
|
Complete
|
|
- |
- - |
1320 |
DELHI TEST HOUSE, Azadhpur
| IS 4923 (2017) |
Hollow steel sections for structural use - Specification (Third Revision) |
- |
-
|
10000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
Cl.7.1(Carbon- IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
500 |
|
NA |
Cl.7.1(Manganese- IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
500 |
|
NA |
Cl.7.1(Sulphur- IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
500 |
|
NA |
Cl.7.1(Phosphorus- IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
500 |
|
NA |
Cl.7.1(Silicon- IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
500 |
|
NA |
Cl.7.1(Aluminium- IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
500 |
|
NA |
Cl.7.1(Copper- IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
500 |
|
NA |
Cl.7.1(Niobium- IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
500 |
|
NA |
Cl.7.1(Vanadium- IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
500 |
|
NA |
Cl.7.1(Titanium- IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
500 |
|
NA |
Cl.7.1(Nitrogen- IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
1500 |
|
NA |
Cl.7.1(Carbon Equivalent-IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
100 |
|
NA |
Cl.9.1, Table 1(Dimensions and Properties of Hollow Sections (Depth)) |
- |
100 |
|
NA |
Cl.9.1, Table 1(Dimensions and Properties of Hollow Sections (Width)) |
- |
100 |
|
NA |
Cl.9.1, Table 1(Dimensions and Properties of Hollow Sections(Thickness)) |
- |
100 |
|
NA |
Cl.9.1, Table 1(Dimensions and Properties of Hollow Sections (Weigth)) |
- |
100 |
|
NA |
Cl.9.1, Table 1(Dimensions and Properties of Hollow Sections (Area of Section)) |
- |
100 |
|
NA |
Cl.9.1, Table 1(Dimensions and Properties of Hollow Sections (Moment of Inertia)) |
- |
100 |
|
NA |
Cl.9.1, Table 1(Dimensions and Properties of Hollow Sections (Moment of Inertia about X-X)) |
- |
100 |
|
NA |
Cl.9.1, Table 1(Dimensions and Properties of Hollow Sections (Moment of Inertia about Y-Y)) |
- |
100 |
|
NA |
Cl.9.1, Table 1(Dimensions and Properties of Hollow Sections (Radius of Gyration)) |
- |
100 |
|
NA |
Cl.9.1, Table 1(Dimensions and Properties of Hollow Sections (Radius of Gyration about X-X)) |
- |
100 |
|
NA |
Cl.9.1, Table 1(Dimensions and Properties of Hollow Sections(Radius of Gyration about Y-Y)) |
- |
100 |
|
NA |
Cl.9.1, Table 1(Dimensions and Properties of Hollow Sections(Elastic Modulus)) |
- |
100 |
|
NA |
Cl.9.1, Table 1(Dimensions and Properties of Hollow Sections (Elastic Modulus about X-X)) |
- |
100 |
|
NA |
Cl.9.1, Table 1(Dimensions and Properties of Hollow Sections (Elastic Modulus about Y-Y)) |
- |
100 |
|
NA |
Cl.9.1, Table 1(Dimensions and Properties of Hollow Sections (Plastic Modulus)) |
- |
100 |
|
NA |
Cl.9.1, Table 1(Dimensions and Properties of Hollow Sections (Plastic Modulus about X-X)) |
- |
100 |
|
NA |
Cl.9.1, Table 1(Dimensions and Properties of Hollow Sections(Plastic Modulus about Y-Y)) |
- |
100 |
|
NA |
Cl. 10.1, 14.1, 18.1(Straightness) |
- |
100 |
|
NA |
Cl. 10.2, Fig 1(Outside dimension (B)) |
- |
100 |
|
NA |
Cl. 10.2, Fig 1(Outside dimension (H)) |
- |
100 |
|
NA |
Cl. 10.2, Fig 1(Outside dimension (T)) |
- |
100 |
|
NA |
Cl. 10.4, Fig 2(Concavity, X1) |
- |
250 |
|
NA |
Cl. 10.4, Fig 2(Convexity, X2) |
- |
250 |
|
NA |
Cl. 10.5, Fig 3(Squareness of side) |
- |
250 |
|
NA |
Cl. 10.6, Fig 4(External Corner Radius) |
- |
250 |
|
NA |
Cl. 10.7, Fig 5(Total twist, V) |
- |
250 |
|
NA |
Cl. 15.2, Table 3(Tensile Strength- IS 1608) |
- |
1500 |
|
NA |
Cl. 15.2, Table 3(Yield Strength- IS 1608) |
- |
1500 |
|
NA |
Cl. 15.2, Table 3(Elongation- IS 1608) |
- |
1500 |
|
NA |
Cl. 14.1(Exact Length) |
- |
100 |
|
NA |
Cl. 14.1(Random Length) |
- |
100 |
|
NA |
Cl. 14.1(Weight on individual length) |
- |
100 |
|
NA |
7(Micro Alloying elements(Nb+V+Ti)) |
- |
1500 |
|
NA |
7(Carbon equivalent as CE) |
- |
500 |
|
NA |
10.4(Concavity/Convexity-SOP MT-23) |
- |
500 |
|
NA |
10.5(Squareness of corner/Sides-SOP MT-23) |
- |
250 |
|
NA |
10.6("External corner Radius/
Radii of corners-outside
- SOP MT-23") |
- |
250 |
|
NA |
11(Oiling & Painting - IS 4923) |
- |
250 |
|
NA |
10.3(Thickness - IS 4923) |
- |
100 |
|
NA |
Cl-19(Mechanical Tests) |
- |
4500 |
|
NA |
|
Complete
|
|
- |
- - |