| 12841 |
BIS, Central Laboratory (CL)
| None
| IS 302 : Part 2 : Sec 30 (2007) |
Safety of household and similar electrical appliances: Part 2 particular requirements: Sec 30 room heaters (First Revision) |
- |
- View breakup
Rs.9950/- up to and including 1 Kw Rs. 10900/- up to and including 2 Kw
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl.6 (Classification) |
- |
|
|
|
| Cl.7 & IS:302-1:2008 (Marking and Instructions) |
- |
|
|
|
| Cl.7 & IS:302-1:2008 (Marking and Instructions) |
- |
|
|
|
| Cl.7 & IS:302-1:2008 (Marking and Instructions) |
- |
|
|
|
| Cl.7 & IS:302-1:2008 (Marking and Instructions) |
- |
|
|
|
| Cl.7 & IS:302-1:2008 (Marking and Instructions) |
- |
|
|
|
| Cl.7 & IS:302-1:2008 (Marking and Instructions) |
- |
|
|
|
| Cl.7 & IS:302-1:2008 (Marking and Instructions) |
- |
|
|
|
| Cl.7 & IS:302-1:2008 (Marking and Instructions) |
- |
|
|
|
| Cl.7 (Marking and Instructions) |
- |
|
|
|
| Cl.7 (Marking and Instructions) |
- |
|
|
|
| Cl.7 (Marking and Instructions) |
- |
|
|
|
| Cl.7.3 (Marking and Instructions) |
- |
|
|
|
| Cl.7.3 (Marking and Instructions) |
- |
|
|
|
| Cl.7.3 (Marking and Instructions) |
- |
|
|
|
| Cl.7.4 (Marking and Instructions) |
- |
|
|
|
| Cl.7.5 (Marking and Instructions) |
- |
|
|
|
| Cl.7.6 & IS:302-1:2008 (Marking and Instructions) |
- |
|
|
|
| Cl.7.8 of IS :302-1:2008 (Marking and Instructions) |
- |
|
|
|
| Cl.7.9 of IS :302-1:2008 (Marking and Instructions) |
- |
|
|
|
| Cl.7.10 of IS :302-1:2008 (Marking and Instructions) |
- |
|
|
|
| Cl.7.11 of IS :302-1:2008 (Marking and Instructions) |
- |
|
|
|
| Cl.7.12 & IS:302-1:2008 (Marking and Instructions) |
- |
|
|
|
| Cl.7.12 & IS:302-1:2008 (Marking and Instructions) |
- |
|
|
|
| Cl.7.12 & IS:302-1:2008 (Marking and Instructions) |
- |
|
|
|
| Cl.7.12 & IS:302-1:2008 (Marking and Instructions) |
- |
|
|
|
| Cl.7.12 & IS:302-1:2008 (Marking and Instructions) |
- |
|
|
|
| Cl.7.12 & IS:302-1:2008 (Marking and Instructions) |
- |
|
|
|
| Cl.7.12 & IS:302-1:2008 (Marking and Instructions) |
- |
|
|
|
| Cl.7.12 & IS:302-1:2008 (Marking and Instructions) |
- |
|
|
|
| Cl.7.12.1 & IS:302-1:2008 (Marking and Instructions) |
- |
|
|
|
| Cl.7.12.1 & IS:302-1:2008 (Marking and Instructions) |
- |
|
|
|
| Cl.7.12.1 & IS:302-1:2008 (Marking and Instructions) |
- |
|
|
|
| Cl.7.12.1 & IS:302-1:2008 (Marking and Instructions) |
- |
|
|
|
| Cl.7.12.1 & IS:302-1:2008 (Marking and Instructions) |
- |
|
|
|
| Cl.7.12.1 & IS:302-1:2008 (Marking and Instructions) |
- |
|
|
|
| Cl.7.12.1 & IS:302-1:2008 (Marking and Instructions) |
- |
|
|
|
| Cl.7.12.1 & IS:302-1:2008 (Marking and Instructions) |
- |
|
|
|
| Cl.7.12.1 & IS:302-1:2009 (Marking and Instructions) |
- |
|
|
|
| Cl.7.13 of IS 302-1:2008 (Marking and Instructions) |
- |
|
|
|
| Cl.7.14 of IS302-1:2008 (Marking and Instructions) |
- |
|
|
|
| Cl.7.14 (Marking and Instructions) |
- |
|
|
|
| Cl.7.14 (Marking and Instructions) |
- |
|
|
|
| Cl.7.15 of IS 302-1:2008 (Marking and Instructions) |
- |
|
|
|
| Cl.7.15 of IS 302-1:2008 (Marking and Instructions) |
- |
|
|
|
| Cl.7.15 of IS 302-1:2008 (Marking and Instructions) |
- |
|
|
|
| Cl.7.15 of IS 302-1:2008 (Marking and Instructions) |
- |
|
|
|
| Cl.7.101 (Marking and Instructions) |
- |
|
|
|
| Cl.8 & IS:302-1:2008 (Protection Against Access to Live Parts) |
- |
|
|
|
| Cl.10 & IS:302-1:2008 (Power Input and Current) |
- |
|
|
|
| Cl.11 & IS:302-1:2008 (Heating) |
- |
|
|
|
| Cl.11 & IS:302-1:2008 (Heating) |
- |
|
|
|
| Cl.11 & IS:302-1:2008 (Heating) |
- |
|
|
|
| Cl.11 & IS:302-1:2008 (Heating) |
- |
|
|
|
| Cl.11 & IS:302-1:2008 (Heating) |
- |
|
|
|
| Cl.11 & IS:302-1:2008 (Heating) |
- |
|
|
|
| Cl.11 & IS:302-1:2008 (Heating) |
- |
|
|
|
| Cl.11 & IS:302-1:2008 (Heating) |
- |
|
|
|
| Cl.11 & IS:302-1:2008 (Heating) |
- |
|
|
|
| Cl.11 & IS:302-1:2008 (Heating) |
- |
|
|
|
| Cl.11 & IS:302-1:2008 (Heating) |
- |
|
|
|
| Cl.11.8 (Heating) |
- |
|
|
|
| Cl.11.8 (Heating) |
- |
|
|
|
| Cl.11.8 (Heating) |
- |
|
|
|
| Cl.13 & IS:302-1:2008 (Leakage Current & Electric Strength at operating temp. ) |
- |
|
|
|
| Cl.13 & IS:302-1:2008 (Leakage Current & Electric Strength at operating temp. ) |
- |
|
|
|
| Cl.15 & IS: 302-1:2008 (Moisture Resistance
) |
- |
|
|
|
| Cl.15.3 of IS 302-1:200 (Moisture Resistance
) |
- |
|
|
|
| Cl.16 & IS:302-1:2008 (Leakage Current & Electric Strength ) |
- |
|
|
|
| Cl.16 & IS:302-1:2008 (Leakage Current & Electric Strength ) |
- |
|
|
|
| Cl.18 (Endurance. ) |
- |
|
|
|
| Cl.19 & IS:302-1:2008 (Abnormal Operation.) |
- |
|
|
|
| Cl.19 & IS:302-1:2008 (Abnormal Operation.) |
- |
|
|
|
| Cl.19 & IS:302-1:2008 (Abnormal Operation.) |
- |
|
|
|
| Cl.19.101 (Abnormal Operation.) |
- |
|
|
|
| Cl.19.102 (Abnormal Operation.) |
- |
|
|
|
| Cl.19.103 (Abnormal Operation.) |
- |
|
|
|
| Cl.19.104 (Abnormal Operation.) |
- |
|
|
|
| Cl.19.105 (Abnormal Operation.) |
- |
|
|
|
| Cl.19.106 (Abnormal Operation.) |
- |
|
|
|
| Table 8 of IS 302-1:2008 (Abnormal Operation.) |
- |
|
|
|
| Cl.19.107 (Abnormal Operation.) |
- |
|
|
|
| Cl.19.108 (Abnormal Operation.) |
- |
|
|
|
| Cl.19.109 (Abnormal Operation.) |
- |
|
|
|
| Cl.19.110 (Abnormal Operation.) |
- |
|
|
|
| Cl.19.111 (Abnormal Operation.) |
- |
|
|
|
| Cl.19.114 (Abnormal Operation.) |
- |
|
|
|
| Cl.20 & IS:302-1:2008 (Stability & Mechanical Hazards) |
- |
|
|
|
| Cl.21 & IS:302-1:2008) (Mechanical Strength.) |
- |
|
|
|
| Cl.21.2 of IS 302-1:2008 (Mechanical Strength.) |
- |
|
|
|
| Cl.21.101 (Mechanical Strength.) |
- |
|
|
|
| Cl.21.102 (Mechanical Strength.) |
- |
|
|
|
| Cl.21.103 (Mechanical Strength.) |
- |
|
|
|
| Cl.22.1 of IS 302-1:2008 (Construction) |
- |
|
|
|
| Cl.22.5 of IS 302-1:2008 (Construction) |
- |
|
|
|
| Cl.22.6 of IS 302-1:2008 (Construction) |
- |
|
|
|
| Cl.22.7 of IS 302-1:2008 (Construction) |
- |
|
|
|
| Cl.22.8 of IS 302-1:2008 (Construction) |
- |
|
|
|
| Cl.22.9 of IS 302-1:2008 (Construction) |
- |
|
|
|
| Cl.22.11 (Construction) |
- |
|
|
|
| Cl.22.12 of IS 302-1:2008 (Construction) |
- |
|
|
|
| Cl.22.13 of IS 302-1:2008 (Construction) |
- |
|
|
|
| Cl.22.14 of IS 302-1:2008 (Construction) |
- |
|
|
|
| Cl.22.15 of IS 302-1:2008 (Construction) |
- |
|
|
|
| Cl.22.18 of IS 302-1:2008 (Construction) |
- |
|
|
|
| Cl.22.20 of IS 302-1:2008 (Construction) |
- |
|
|
|
| Cl.22.21 of IS 302-1:2008 (Construction) |
- |
|
|
|
| Cl.23 & IS:302-1:2008 (Internal Wiring
) |
- |
|
|
|
| Cl.23.4 & Cl.29 of 302-1:2008 (Internal Wiring
) |
- |
|
|
|
| Cl.23.5 of 302-1:2008 (Internal Wiring
) |
- |
|
|
|
| Cl.23.7 of 302-1:2008 (Internal Wiring
) |
- |
|
|
|
| C.23.7 of 302-1:2008 (Internal Wiring
) |
- |
|
|
|
| Cl.24.1 of 302-1:2008 (Component) |
- |
|
|
|
| Cl.24.1 of 302-1:2008 (Component) |
- |
|
|
|
| Cl.24.1.3 (Component) |
- |
|
|
|
| Cl.24.1.3 (Component) |
- |
|
|
|
| Cl.24.1.3 (Component) |
- |
|
|
|
| C.24.1.4 (Component) |
- |
|
|
|
| C.24.2 of 302-1:2008 (Component) |
- |
|
|
|
| Cl.24.10 (Component) |
- |
|
|
|
| Cl.25.1 of 302-1:2008 (Supply Connection and External Flexible Cords ) |
- |
|
|
|
| Cl. 25.2 of IS 3021:2008 (Supply Connection and External Flexible Cords ) |
- |
|
|
|
| Cl. 25.3 of IS 302-1:2008 (Supply Connection and External Flexible Cords ) |
- |
|
|
|
| Cl. 25.4 of IS 302-1:2008 (Supply Connection and External Flexible Cords ) |
- |
|
|
|
| Cl.25.5 of 302-1:2008 (Supply Connection and External Flexible Cords ) |
- |
|
|
|
| Cl.25.6 of 302-1:2008 (Supply Connection and External Flexible Cords ) |
- |
|
|
|
| Cl.25.7. (Supply Connection and External Flexible Cords ) |
- |
|
|
|
| Cl.25.8 (Supply Connection and External Flexible Cords ) |
- |
|
|
|
| Cl. 25.9 (Supply Connection and External Flexible Cords ) |
- |
|
|
|
| Cl.25.10 of 302-1:2008 (Supply Connection and External Flexible Cords ) |
- |
|
|
|
| Cl. 25.11 (Supply Connection and External Flexible Cords ) |
- |
|
|
|
| Cl. 25.12 (Supply Connection and External Flexible Cords ) |
- |
|
|
|
| Cl. 25.13 (Supply Connection and External Flexible Cords ) |
- |
|
|
|
| Cl.25.14 of IS 302-1:2008 (Supply Connection and External Flexible Cords ) |
- |
|
|
|
| Cl.25.15 of IS 302-1:2008 (Supply Connection and External Flexible Cords ) |
- |
|
|
|
| Cl.25.17 of IS 302-1:2008 (Supply Connection and External Flexible Cords ) |
- |
|
|
|
| Cl.25.18 (Supply Connection and External Flexible Cords ) |
- |
|
|
|
| Cl.25.20 (Supply Connection and External Flexible Cords ) |
- |
|
|
|
| Cl.26.1 of IS 302-1:2008 (Terminal for External Conductors
) |
- |
|
|
|
| Cl.26.10 of IS 302-1:2008 (Terminal for External Conductors
) |
- |
|
|
|
| Cl.26.11 of IS 302-1:2008 (Terminal for External Conductors
) |
- |
|
|
|
| Cl.27.1 of 302-1:2008 (Provision for Earthing.) |
- |
|
|
|
| Cl.27.5 of 302-1:2008 (Provision for Earthing.) |
- |
|
|
|
| Cl.28 of 302-1:2008 (Screws and Connections.) |
- |
|
|
|
| Cl.29 & IS:302-1:2008 (Clearances, Creepage Distances and Solid Insulation) |
- |
|
|
|
| Cl.29 & IS:302-1:2008 (Clearances, Creepage Distances and Solid Insulation) |
- |
|
|
|
| Cl.30 & IS:302-1:2008 (Resistance to Heat and Fire) |
- |
|
|
|
| Cl.30.2.2 of 302-1:2008 (Resistance to Heat and Fire) |
- |
|
|
|
| Cl.31 & IS:302-1:2008 (Resistance to Rusting.) |
- |
|
|
|
| Cl.32 & IS:302-1:2008 (Radition,Toxicity and similar Hazards.) |
- |
|
|
|
|
- |
- Excluding electronic circuit type appliances(Cl.19.11 of IS 302 part 1) |
| 12842 |
BIS, Central Laboratory (CL)
| None
| IS 8783 : Part 4 : Sec 1 (1995) |
Winding wires for submersible motors - Specification: Part 4 specification for indmdual wires: Sec 1 HR PVC insulated wires (First Revision) |
- |
9300/- View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl.3.1 (Conductor) |
- |
|
|
|
| Cl.4 (Material) |
- |
|
|
|
| Cl.5.1.1 (Dimensions) |
- |
|
|
|
| Cl. 6 (Annealing Test) |
- |
|
|
|
| Cl 6 (Resistance Test) |
- |
|
|
|
| Cl.4.1 (Insulation ) |
- |
|
|
|
| Cl.4.2 (Application) |
- |
|
|
|
| Cl.4.3 (Colour) |
- |
|
|
|
| Cl.4.4 (Overall Diameter) |
- |
|
|
|
| Cl.4.5 (Finish) |
- |
|
|
|
| Cl.4.6 (High Voltage Test Water Immersion ) |
- |
|
|
|
| Cl. 4 Table 1of IS: 8783 (part 2) (Volume resistivity) |
- |
|
|
|
| Cl. 4 Table 1of IS: 8783 (part 2) (Volume resistivity) |
- |
|
|
|
| Cl. 4 Table 1of IS: 8783 (part 2) (Tensile strength ) |
- |
|
|
|
| Cl. 4 Table 1of IS: 8783 (part 2) (Elongation) |
- |
|
|
|
| Cl. 4 Table 1of IS: 8783 (part 2) (Tensile Strength) |
- |
|
|
|
| Cl. 4 Table 1of IS: 8783 (part 2) (Variation) |
- |
|
|
|
| Cl. 4 Table 1of IS: 8783 (part 2) (Elongation at Break ) |
- |
|
|
|
| Cl. 4 Table 1of IS: 8783 (part 2) (Variation) |
- |
|
|
|
| Cl. 4 Table 1of IS: 8783 (part 2) (Shrinkage test ) |
- |
|
|
|
| Cl. 4 Table 1of IS: 8783 (part 2) (Shrinkage test ) |
- |
|
|
|
| Cl. 4 Table 1of IS: 8783 (part 2) (Water absorption (Gravimetric) ) |
- |
|
|
|
| Cl. 4 Table 1of IS: 8783 (part 2) (Hot deformation Test ) |
- |
|
|
|
| Cl. 4 Table 1of IS: 8783 (part 2) (Heat shock Test ) |
- |
|
|
|
| Cl.3.2 (Dielectric Material ) |
- |
|
|
|
|
- |
- - |
| 12843 |
BIS, Central Laboratory (CL)
| None
| IS 302 : Part 1 (2008) |
Safety of household and similar electrical appliances: Part 1 general requirements (Sixth Revision) |
- |
- View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 7 (Marking and instructions) |
- |
|
|
|
| 8.1.1 (Protection against live parts in all positions) |
- |
|
|
|
| 9 (Starting of motor operation test requirements and tests) |
- |
|
|
|
| 10.1 (Power input) |
- |
|
|
|
| 10.2 (Current input) |
- |
|
|
|
| 11.1 (General) |
- |
|
|
|
| 11.2 (General) |
- |
|
|
|
| 11.3 (Heating) |
- |
|
|
|
| 13.1 (General) |
- |
|
|
|
| 13.2 (Leakage current at operating temperature) |
- |
|
|
|
| 13.3 (Electric Strength at operating temperature) |
- |
|
|
|
| 15.1 (Ingress Protection test other than IPX0 (IP test)) |
- |
|
|
|
| 15.2 (Spillage Test) |
- |
|
|
|
| 15.3 (Humidity Test) |
- |
|
|
|
| 16.2 (Leakage Current (after Clause 15)) |
- |
|
|
|
| 16.3 (Electric Strength (after clause 15 and 16.2)) |
- |
|
|
|
| 19 (Abnormal Operation) |
- |
|
|
|
| 20 (Stability test) |
- |
|
|
|
| 21 (Mechanical Strength Test) |
- |
|
|
|
| 22 (Construction verification related test) |
- |
|
|
|
| 23 (General) |
- |
|
|
|
| 24 (Components) |
- |
|
|
|
| 25 (Supply connection and external flexible cords) |
- |
|
|
|
| 26 (Terminals for external conductors) |
- |
|
|
|
| 27 (Provision for earthing) |
- |
|
|
|
| 28 (Screw test and connections) |
- |
|
|
|
| 29 (clearance, creepage distances and solid insulation) |
- |
|
|
|
| 30.1 (Ball pressure test) |
- |
|
|
|
| 30.2 (Glow Wire Test) |
- |
|
|
|
| 31 (Resistance to Rusting) |
- |
|
|
|
| 32 (Radiation Toxicity and Similar Hazards) |
- |
|
|
|
| 6 (Classification- IS 302-1) |
- |
|
|
|
| 17 (Over Load Protection of Transformers and associated circuits) |
- |
|
|
|
| 18 (Endurance Test requirements and tests) |
- |
|
|
|
|
- |
view Scope file View scope file |
| 12844 |
Ace Test Labs & Metrology Pvt. Ltd., Sonipat
| 9162826
| IS 302 : Part 2 : Sec 30 (2007) |
Safety of household and similar electrical appliances: Part 2 particular requirements: Sec 30 room heaters (First Revision) |
- |
17000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl.7(Marking and Instructions) |
- |
100 |
|
10% Discount for BIS |
| Cl.8 & IS:302-1:2008(Protection Against Access to Live Parts) |
- |
300 |
|
10% Discount for BIS |
| Cl.10 & IS:302-1:2008(Power Input and Current) |
- |
500 |
|
10% Discount for BIS |
| Cl.11.8(Heating) |
- |
300 |
|
10% Discount for BIS |
| Cl.13 & IS:302-1:2008(Leakage Current & Electric Strength at operating temp. ) |
- |
500 |
|
10% Discount for BIS |
| Cl.14 & IS:302-1:2008(Transient Over Voltages) |
- |
300 |
|
10% Discount for BIS |
| Cl.15 & IS: 302-1:2008(Moisture Resistance
) |
- |
1000 |
|
10% Discount for BIS |
| Cl.16 & IS:302-1:2008(Leakage Current & Electric Strength ) |
- |
500 |
|
10% Discount for BIS |
| Cl.16 & IS:302-1:2008(Leakage Current & Electric Strength ) |
- |
500 |
|
10% Discount for BIS |
| Cl.17 & IS:302-1:2008(Over load Protection of Transformers and Associated Circuits ) |
- |
300 |
|
10% Discount for BIS |
| Cl.19 & IS:302-1:2008(Abnormal Operation.) |
- |
200 |
|
10% Discount for BIS |
| Cl.20 & IS:302-1:2008(Stability & Mechanical Hazards) |
- |
450 |
|
10% Discount for BIS |
| Cl.21 & IS:302-1:2008)(Mechanical Strength.) |
- |
450 |
|
10% Discount for BIS |
| Cl.22.1 of IS 302-1:2008(Construction) |
- |
2500 |
|
10% Discount for BIS |
| Cl.23 & IS:302-1:2008(Internal Wiring
) |
- |
200 |
|
10% Discount for BIS |
| Cl.25.1 of 302-1:2008(Supply Connection and External Flexible Cords ) |
- |
200 |
|
10% Discount for BIS |
| Cl.26.1 of IS 302-1:2008(Terminal for External Conductors
) |
- |
200 |
|
10% Discount for BIS |
| Cl.27.1 of 302-1:2008(Provision for Earthing.) |
- |
200 |
|
10% Discount for BIS |
| Cl.28 of 302-1:2008(Screws and Connections.) |
- |
300 |
|
10% Discount for BIS |
| Cl.29 & IS:302-1:2008(Clearances, Creepage Distances and Solid Insulation) |
- |
500 |
|
10% Discount for BIS |
| Cl.30 & IS:302-1:2008(Resistance to Heat and Fire) |
- |
1000 |
|
10% Discount for BIS |
|
14 Nov, 2027 |
- Included w.e.f. 17-6-2021. EXCLUSION EMI/EMC (Cl.19.11.4.1 to Cl.19.11.4.4.) |
| 12845 |
Ace Test Labs & Metrology Pvt. Ltd., Sonipat
| 9162826
| IS 302 : Part 2 : Sec 14 (2009) |
Safety of household and similar electrical appliances: Part 2 particular requirements: Sec 14 electric kitchen machines (First Revision) |
- |
20000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 7.1(Marking- IS 302-1) |
- |
500 |
|
10% Discount for BIS |
| 8( Protection Against Electric Shock, IS 302-1) |
- |
700 |
|
10% Discount for BIS |
| 10(Power Input and Current, IS 302-1) |
- |
1000 |
|
10% Discount for BIS |
| 11(Heating, IS 302-1) |
- |
700 |
|
10% Discount for BIS |
| 13(Electrical Insulation and Leakage Current at Operating Temperature: Leakage current, IS 302-1) |
- |
700 |
|
10% Discount for BIS |
| 14(Transient Over Voltages, IS 302-1) |
- |
500 |
|
10% Discount for BIS |
| 15.1(Moisture Resistance, IS 302-1) |
- |
2000 |
|
10% Discount for BIS |
| 16(Electrical Insulation and Leakage Current at Operating Temperature: Leakage current, IS 302-1) |
- |
700 |
|
10% Discount for BIS |
| 17(Overload protection of Transformers and Associated Circuits, IS 302-1) |
- |
700 |
|
10% Discount for BIS |
| 19.7(Abnormal Operation, IS 302-1) |
- |
750 |
|
10% Discount for BIS |
| 20.1(Stability & Mechanical Hazards, IS 302-1) |
- |
750 |
|
10% Discount for BIS |
| 22(Construction, IS 302-1) |
- |
2800 |
|
10% Discount for BIS |
| 23.1(Internal Wiring, IS 302-1) |
- |
900 |
|
10% Discount for BIS |
| 25.1(Supply Connection and External Flexible Cords, IS 302-1) |
- |
1000 |
|
10% Discount for BIS |
| 26(Terminals for External Conductors, IS 302-1) |
- |
700 |
|
10% Discount for BIS |
| 27(Provision for Earthing, IS 302-1) |
- |
500 |
|
10% Discount for BIS |
| 28(Screws & Connections, IS 302-1) |
- |
500 |
|
10% Discount for BIS |
| 29.1(Clearances, Creepage distances and Solid Insulation, IS 302-1) |
- |
900 |
|
10% Discount for BIS |
| 30.1(Resistance to Heat and Fire, IS 302-1) |
- |
2000 |
|
10% Discount for BIS |
| 31(Resistance of Rusting, IS 302-1) |
- |
1000 |
|
10% Discount for BIS |
| 21.1(Mechanical Strength, IS 302-1) |
- |
700 |
|
10% Discount for BIS |
|
14 Nov, 2027 |
- Included w.e.f. 17-6-2021. EXCLUSION :EMI/EMC (Cl.19.11.4.1 to Cl.19.11.4.4.) |
| 12846 |
Ace Test Labs & Metrology Pvt. Ltd., Sonipat
| 9162826
| IS 302 : Part 2 : Sec 3 (2007) |
Safety of household and similar electrical appliances: Part 2 particular requirements: Sec 3 electric iron (First Revision) |
- |
15000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 7.1(Marking- IS 302-1) |
- |
100 |
|
10% Discount for BIS |
| 8( Protection Against Electric Shock, IS 302-1) |
- |
100 |
|
10% Discount for BIS |
| 10(Power Input and Current, IS 302-1) |
- |
100 |
|
10% Discount for BIS |
| 11(Heating, IS 302-1) |
- |
100 |
|
10% Discount for BIS |
| 13(Electrical Insulation and Leakage Current at Operating Temperature: Leakage current, IS 302-1) |
- |
100 |
|
10% Discount for BIS |
| 14(Transient Over Voltages, IS 302-1) |
- |
100 |
|
10% Discount for BIS |
| 15.1(Moisture Resistance, IS 302-1) |
- |
100 |
|
10% Discount for BIS |
| 16(Electrical Insulation and Leakage Current at Operating Temperature: Leakage current, IS 302-1) |
- |
100 |
|
10% Discount for BIS |
| 19.4(Abnormal Operation, IS 302-1) |
- |
100 |
|
10% Discount for BIS |
| 19.4(Abnormal Operation, IS 302-1) |
- |
100 |
|
10% Discount for BIS |
| 20.1(Stability & Mechanical Hazards, IS 302-1) |
- |
100 |
|
10% Discount for BIS |
| 21.1(Mechanical Strength, IS 302-1) |
- |
100 |
|
10% Discount for BIS |
| 22(Construction, IS 302-1) |
- |
500 |
|
10% Discount for BIS |
| 23.1(Internal Wiring, IS 302-1) |
- |
100 |
|
10% Discount for BIS |
| 25.1(Supply Connection and External Flexible Cords, IS 302-1) |
- |
100 |
|
10% Discount for BIS |
| 26(Terminals for External Conductors, IS 302-1) |
- |
100 |
|
10% Discount for BIS |
| 27.1(Provision for Earthing, IS 302-1) |
- |
100 |
|
10% Discount for BIS |
| 28(Screws & Connections, IS 302-1) |
- |
100 |
|
10% Discount for BIS |
| 29.1(Clearances, Creepage distances and Solid Insulation, IS 302-1) |
- |
100 |
|
10% Discount for BIS |
| 30.1(Resistance to Heat, Fire & Tracking, IS 302-1) |
- |
1200 |
|
10% Discount for BIS |
| 31(Resistance of Rusting, IS 302-1) |
- |
100 |
|
10% Discount for BIS |
|
14 Nov, 2027 |
- Included w.e.f. 17-6-2021. EXCLUSION EMI/EMC (Cl.19.11.4.1 to Cl.19.11.4.4.) |
| 12847 |
Ace Test Labs & Metrology Pvt. Ltd., Sonipat
| 9162826
| IS 302 : Part 2 : Sec 202 (1992) |
Safety of household and similar electrical appliances: Part 2 particular requirements: Sec 202 electric stoves |
- |
15000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 7.1(Marking- IS 302-1) |
- |
50 |
|
10% Discount for BIS |
| 8( Protection Against Electric Shock, IS 302-1) |
- |
50 |
|
10% Discount for BIS |
| 10(Power Input and Current, IS 302-1) |
- |
50 |
|
10% Discount for BIS |
| 11(Heating, IS 302-1) |
- |
50 |
|
10% Discount for BIS |
| 12(Operation under overload conditions of appliances with heating elements, IS 302-2-202: 1992) |
- |
50 |
|
10% Discount for BIS |
| 13(Electrical Insulation and Leakage Current at Operating Temperature: Leakage current, IS 302-1) |
- |
50 |
|
10% Discount for BIS |
| 15.1(Moisture Resistance, IS 302-1) |
- |
50 |
|
10% Discount for BIS |
| 16(Electrical Insulation and Leakage Current at Operating Temperature: Leakage current, IS 302-1) |
- |
100 |
|
10% Discount for BIS |
| 19.2(Abnormal Operation, IS 302-1) |
- |
100 |
|
10% Discount for BIS |
| 20.1(Stability & Mechanical Hazards, IS 302-1) |
- |
50 |
|
10% Discount for BIS |
| 21.1(Mechanical Strength, IS 302-1 & IS 302-2-202) |
- |
50 |
|
10% Discount for BIS |
| 22(Construction, IS 302-1) |
- |
950 |
|
10% Discount for BIS |
| 23.1(Internal Wiring, IS 302-1) |
- |
50 |
|
10% Discount for BIS |
| 25.1(Supply Connection and External Flexible Cords, IS 302-1) |
- |
50 |
|
10% Discount for BIS |
| 26(Terminals for External Conductors, IS 302-1) |
- |
50 |
|
10% Discount for BIS |
| 27.1(Provision for Earthing, IS 302-1) |
- |
50 |
|
10% Discount for BIS |
| 28(Screws & Connections, IS 302-1) |
- |
50 |
|
10% Discount for BIS |
| 29.1(Clearances, Creepage distances and Solid Insulation, IS 302-1) |
- |
50 |
|
10% Discount for BIS |
| 30.1(Resistance to Heat, Fire & Tracking, IS 302-1) |
- |
25 |
|
10% Discount for BIS |
| 30.2(Resistance to Heat, Fire & Tracking, IS 302-1) |
- |
250 |
|
10% Discount for BIS |
| 31(Resistance of Rusting, IS 302-1) |
- |
50 |
|
10% Discount for BIS |
|
14 Nov, 2027 |
- Exclusion: 24.1 (Components), 22 (Construction |
| 12848 |
Ace Test Labs & Metrology Pvt. Ltd., Sonipat
| 9162826
| IS 302 : Part 2 : Sec 201 (2008) |
Safety of household and similar electrical appliances: Part 2 particular requirements: Sec 201 electric immersion water heaters (First Revision) |
- |
15000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl.7 of IS 302-2-201:2008(Marking and Instruction ) |
- |
100 |
|
10% Discount for BIS |
| Cl.8 of IS 302‐2-201: 2008(Protection Against Access to Live Parts) |
- |
300 |
|
10% Discount for BIS |
| Cl.10 of IS 302‐2‐201:2008(Power Input and Current ) |
- |
500 |
|
10% Discount for BIS |
| Cl.11 of IS 302-2201: 2008(Heating) |
- |
300 |
|
10% Discount for BIS |
| Cl.13 of IS 302-2-201: 2008(Leakage Current & Electric Strength at Operating Temperature) |
- |
500 |
|
10% Discount for BIS |
| Cl.15 of IS 302-2-201:2008(Moisture Resistance ) |
- |
1000 |
|
10% Discount for BIS |
| Cl.16 of IS 302-2-201:2008(Leakage Current & Electric Strength) |
- |
500 |
|
10% Discount for BIS |
| Cl.17 of IS 302‐2-201: 2008(Overload Protection of Transformers & Associated Circuits) |
- |
300 |
|
10% Discount for BIS |
| Cl.19 of IS 302‐2-201: 2008(Abnormal Operation ) |
- |
200 |
|
10% Discount for BIS |
| Cl.20 of IS 302-2-201: 2008(Stability & Mechanical Hazards) |
- |
450 |
|
10% Discount for BIS |
| Cl.21 of IS 302-2-201: 2008(Mechanical Strength ) |
- |
450 |
|
10% Discount for BIS |
| Cl.21 of IS 302-2-201: 2008(Mechanical Strength ) |
- |
450 |
|
10% Discount for BIS |
| Cl.22 of IS 302-2-201: 2008(Construction) |
- |
2500 |
|
10% Discount for BIS |
| Cl.23 of 302-2-201:2008(Internal Wiring ) |
- |
200 |
|
10% Discount for BIS |
| Cl.25 of IS 302-2-201: 2008(Supply Connection and External Flexible Cords) |
- |
200 |
|
10% Discount for BIS |
| Cl.26 of IS 302-2-201: 2008(Terminals for External Conductors) |
- |
200 |
|
10% Discount for BIS |
| Cl.27 of IS 302-2-201: 2008(Provision for Earthing ) |
- |
200 |
|
10% Discount for BIS |
| Cl.28 of IS 302-2-201: 2008(Screws & Connections ) |
- |
300 |
|
10% Discount for BIS |
| Cl.29 of IS 302-2‐201:2008(Clearances, Creepage Distances and Solid Insulation ) |
- |
300 |
|
10% Discount for BIS |
| Cl.30 of IS 302-2‐201:2008(Resistance to Heat and Fire ) |
- |
1000 |
|
10% Discount for BIS |
| Cl.31 of IS 302-2-201:2008(Resistance of Rusting ) |
- |
200 |
|
10% Discount for BIS |
| Cl.14 of IS 302‐2-201:2008(Transient Over Voltages ) |
- |
300 |
|
10% Discount for BIS |
|
14 Nov, 2027 |
- Included w.e.f. 17-6-2021. EXCLUSION EMI/EMC (Cl.19.11.4.1 to Cl.19.11.4.4.) |
| 12849 |
BIS, Eastern Regional Laboratory (ERL)
| None
| IS 12045 (1987) |
Specification for alloys used in electrical resistance metallic heating elements |
For all types except test mentioned in remarks |
- View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 2.1 (Nickel- Standard Instrumental/Chemical Method) |
- |
|
|
|
| 2.1 (Chromium- Standard Instrumental/Chemical Method) |
- |
|
|
|
| 2.1 (Carbon- Standard Instrumental/Chemical Method) |
- |
|
|
|
| 2.1 (Silicon- Standard Instrumental/Chemical Method) |
- |
|
|
|
| 2.1 (Manganese- Standard Instrumental/Chemical Method) |
- |
|
|
|
| 3.1 (Tensile Strength-IS 1608 (P- 1)) |
- |
|
|
|
| 3.1 (Hardness- IS 1586 (P-1)) |
- |
|
|
|
|
- |
- Except accelerated life test |
| 12850 |
BIS, Eastern Regional Laboratory (ERL)
| None
| IS 11952 (1986) |
Specification for steels for piston pins (Gudgeon Pins) |
For all grades except test mentioned in remarks |
- View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4.1,4.2 Table 1 (Carbon-Relevant parts of IS 228) |
- |
|
|
|
| 4.1,4.2 Table 1 (Silicon-Relevant parts of IS 228) |
- |
|
|
|
| 4.1,4.2 Table 1 (Manganese-Relevant parts of IS 228) |
- |
|
|
|
| 4.1,4.2 Table 1 (Sulphur-Relevant parts of IS 228) |
- |
|
|
|
| 4.1,4.2 Table 1 (Phosphorous-Relevant parts of IS 228) |
- |
|
|
|
| 4.1,4.2 Table 1 (Chromium-Relevant parts of IS 228) |
- |
|
|
|
| 4.1,4.2 Table 1 (Nickel-Relevant parts of IS 228) |
- |
|
|
|
| 4.1,4.2 Table 1 (Molybdenum-Relevant parts of IS 228) |
- |
|
|
|
| 4.3 (Copper-Relevant parts of IS 228) |
- |
|
|
|
| 5.2, Table3 (i) Tensile Strength) |
- |
|
|
|
| 5.2, Table3 (ii) Hardness) |
- |
|
|
|
| 10 (SURFACE DEFECTS) |
- |
|
|
|
| 11 (TOLERANCES) |
- |
|
|
|
| 6 (Inclusions) |
- |
|
|
|
| 8 (GRAIN SIZE) |
- |
|
|
|
|
- |
- Chem: Facility not available Parameter: B, Nb, V, Ti
Mech: Except Magnetic Particle test |
| 12851 |
BIS, Eastern Regional Laboratory (ERL)
| None
| IS 9476 (1980) |
Specification for cold-rolled steel strips for carbon steel razor blades |
- |
525 for Physical + carbide density test View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4.1 (Carbon- IS 228) |
- |
|
|
|
| Cl. 4.1 (Carbon) |
- |
|
|
|
| 4.1 (Manganese- IS 228) |
- |
|
|
|
| Cl. 4.1 (Manganese) |
- |
|
|
|
| 4.1 (Silicon- IS 228) |
- |
|
|
|
| Cl. 4.1 (Silicon) |
- |
|
|
|
| 4.1 (Sulphur- IS 228) |
- |
|
|
|
| Cl. 4.1 (Sulphur) |
- |
|
|
|
| 4.1 (Phosphorous- IS 228) |
- |
|
|
|
| Cl. 4.1 (Phosphorus) |
- |
|
|
|
| 4.1 (Chromium- IS 228) |
- |
|
|
|
| Cl. 4.1 (Chromium) |
- |
|
|
|
| 4.1 (Sulphur+Phosphorous- IS 228) |
- |
|
|
|
| Cl. 4.1 (Sulphur + Phosphorus) |
- |
|
|
|
| 3.1 (Nitrogen- IS 228) |
- |
|
|
|
| 5 (. HARDNESS TEST IS : 9258-1979* ) |
- |
|
|
|
| 6.1 (IS:7739 ( Part V )) |
- |
|
|
|
| 7 (FREEDOM FROM DEFECTS) |
- |
|
|
|
| 9 (EDGE CONDITION) |
- |
|
|
|
| 10.1 (Width and thickness) |
- |
|
|
|
| 10.2 ( Camber) |
- |
|
|
|
| 11 (. SURFACE FINISH) |
- |
|
|
|
| 6.2 ( Carbide Density) |
- |
|
|
|
|
- |
- Complete |
| 12852 |
Envirocare Labs Pvt Ltd, Thane
| 7120616
| IS 7224 (2006) |
Iodized salt, vacuum evaporated iodized salt and refined iodized salt - Specification (Second Revision) |
-- |
4647.5 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Clause 4.2(Particle Size) |
- |
130 |
|
- |
| Clause 4.3 Table 1(Moisture content) |
- |
195 |
|
- |
| Clause 4.3 Table 1(water insoluble matter) |
- |
195 |
|
- |
| Clause 4.3 Table 1(Chloride Content(as Nacl)) |
- |
260 |
|
- |
| Clause 4.3 Table 1(Matter soluble in water other than sodium chloride) |
- |
195 |
|
- |
| Clause 4.3 Table 1(Calcium (as Ca)) |
- |
357.5 |
|
- |
| Clause 4.3 Table 1(Magnesium (as mg)) |
- |
357.5 |
|
- |
| Clause 4.3 Table 1(Sulphate (as SO4 ),) |
- |
357.5 |
|
- |
| Clause 4.3 Table 1(Iodine content, a) Manufacturers Level ) |
- |
552.5 |
|
- |
| Clause 4.3 Table 1(Alkalinity (as Na2CO3),) |
- |
357.5 |
|
- |
| Clause 4.3 Table 1(Lead as (Pb)) |
- |
357.5 |
|
- |
| Clause 4.3 Table 1(Arsenic(as As)) |
- |
357.5 |
|
- |
| Clause 4.3 Table 1(Iron(as Fe)) |
- |
357.5 |
|
- |
| Clause no4.1(Description) |
- |
65 |
|
- |
|
25 May, 2027 |
- - |
| 12853 |
BIS, Eastern Regional Laboratory (ERL)
| None
| IS 15392 (2003) |
Aluminium and aluminium alloy bare foil for food packaging - Specification |
For all grades except tests mentioned in remarks |
3371 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Clause 7
Sub-Clause 7.1 (Material) |
- |
|
|
|
| Clause 5
Table 1 (PINHOLE COUNT) |
- |
|
|
|
| Clause 6 (FREEDOM FROM DEFECTS) |
- |
|
|
|
| Clause 14 (Surface condition) |
- |
|
|
|
| Clause 11 (Average Thickness) |
- |
|
|
|
| Clause 7
Sub-Clause 7.1 (Material) |
- |
|
|
|
| Clause 5
Table 1 (PINHOLE COUNT) |
- |
|
|
|
| Clause 7
Sub-Clause 7.2 (Material) |
- |
|
|
|
| Clause 7
Sub-Clause 7.1 (Material) |
- |
|
|
|
| Clause 12 (Dimension and Tolerances: I) Width) |
- |
|
|
|
| 7 (Copper- IS 504) |
- |
|
|
|
| 7 (Magnesium-IS 504) |
- |
|
|
|
| 7 (Silicon- IS 504) |
- |
|
|
|
| 7 (Iron-IS 504) |
- |
|
|
|
| 7 (Manganese-IS 504) |
- |
|
|
|
| 7 (Zinc-IS 504) |
- |
|
|
|
| 7 (Titanium- IS 504) |
- |
|
|
|
| 7 (Chromium- IS 504) |
- |
|
|
|
| 7 (Cu+Si+Fe+Mn+Zn) |
- |
|
|
|
| 7 (Cu+Mg+Si+Pe+Mn+Zn) |
- |
|
|
|
| 13-(Table-5) (Tensile properties-IS 13237) |
- |
|
|
|
|
- |
- Chem: Except Al, V |
| 12854 |
CENTRAL INSTITUTE OF PETROCHEMICALS ENGINEERING AND TECHNOLOGY (CIPET):CSTS-BHOPAL
| 8100534
| IS 12785 (1994) |
Irrigation equipment - Strainer - Type filters - Specification (first revision) |
- |
11250 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4.1.1(Zinc Coating - IS 4736) |
- |
0 |
|
Nil |
| 4.1.1(General) |
- |
500 |
|
Nil |
| 4.1.1(General) |
- |
0 |
|
Charges already taken in clause no. 4.1.1 |
| 4.1.1(General) |
- |
0 |
|
Charges already taken in clause no. 4.1.1 |
| 4.1.1(General) |
- |
0 |
|
Charges already taken in clause no. 4.1.1 |
| 4.1.1(General) |
- |
0 |
|
Charges already taken in clause no. 4.1.1 |
| 4.1.1(General - The hot dip galvanizing shall be done in accordance with IS 4736 with a minimum zinc coating) |
- |
0 |
|
Charges already taken in clause no. 4.1.1 |
| 4.1.1(General - Thickness of powder coating
IS 5116.) |
- |
0 |
|
Charges already taken in clause no. 4.1.1 |
| 4.1.2(General) |
- |
0 |
|
Charges already taken in clause no. 4.1.1 |
| 4.1.2(General) |
- |
0 |
|
Charges already taken in clause no. 4.1.1 |
| 4.1.3(General) |
- |
0 |
|
Charges already taken in clause no. 4.1.1 |
| 4.1.4(General) |
- |
0 |
|
Charges already taken in clause no. 4.1.1 |
| 4.2.1(Strainer Housing) |
- |
500 |
|
Nil |
| 4.2.2(Strainer Housing) |
- |
0 |
|
Charges already taken in clause no. 4.2.1 |
| 4.2.3(Strainer Housing) |
- |
0 |
|
Charges already taken in clause no. 4.2.1 |
| 4.3.1(Connections
IS 2643 : 1975.) |
- |
500 |
|
Nil |
| 4.3.2(Connections
IS 6418 : 1971) |
- |
0 |
|
Charges already taken in clause no. 4.3.1 |
| 4.3.3(Connections) |
- |
0 |
|
Charges already taken in clause no. 4.2.1 |
| 4.3.4(Connections) |
- |
0 |
|
Charges already taken in clause no. 4.2.1 |
| 6.1(MECHANiCAL TESTS) |
- |
1500 |
|
Nil |
| 6.1(MECHANiCAL TESTS) |
- |
0 |
|
Charges already taken in clause no. 6.1 |
| 6.2(MECHANiCAL TESTS ) |
- |
3750 |
|
Nil |
| 6.3(MECHANiCAL TESTS ) |
- |
1000 |
|
Nil |
| 6.4(MECHANiCAL TESTS ) |
- |
1000 |
|
nIL |
| 6.5(MECHANiCAL TESTS ) |
- |
2500 |
|
Nil |
|
31 Dec, 2026 |
- Included w.e.f. 27-05-2022. |
| 12855 |
CENTRAL INSTITUTE OF PETROCHEMICALS ENGINEERING AND TECHNOLOGY (CIPET):CSTS-BHOPAL
| 8100534
| IS 12701 (1996) |
Rotational moulded polyethylene water storage tanks - specification (First Revision) |
- |
17150.00 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4.2.3(Carbon Black Content ) |
- |
925 |
|
Nil |
| 4.2.3(Carbon Dispersion Test) |
- |
700 |
|
Nil |
| 5(Types and Features ) |
- |
0 |
|
Nil |
| 5.1 Table 1(Dimensioas of Cylinderical Vertical Tank) |
- |
3050 |
|
Nil |
| 5.1 Table 1(Dimensioas of Cylinderical Vertical Tank) |
- |
0 |
|
Charges already taken in clause no. 5.1 Table 1 |
| 5.1 Table 1(Dimensioas of Cylinderical Vertical Tank) |
- |
0 |
|
Charges already taken in clause no. 5.1 Table 1 |
| 5.1 Table 1(Dimensioas of Cylinderical Vertical Tank) |
- |
0 |
|
Charges already taken in clause no. 5.1 Table 1 |
| 5.1 Table 1(Dimensioas of Cylinderical Vertical Tank) |
- |
0 |
|
Charges already taken in clause no. 5.1 Table 1 |
| 5.1 Table 1(Dimensioas of Cylinderical Vertical Tank) |
- |
0 |
|
Charges already taken in clause no. 5.1 Table 1 |
| 5.1 Table 1(Dimensioas of Cylinderical Vertical Tank) |
- |
0 |
|
Charges already taken in clause no. 5.1 Table 1 |
| 5.1 Table 1(Dimensioas of Cylinderical Vertical Tank) |
- |
0 |
|
Charges already taken in clause no. 5.1 Table 1 |
| 5.2 Table 2(Dimensions of Rectangular Loft Tanks) |
- |
0 |
|
Charges already taken in clause no. 5.1 Table 1 |
| 5.2 Table 2(Dimensions of Rectangular Loft Tanks) |
- |
0 |
|
Charges already taken in clause no. 5.1 Table 1 |
| 5.2 Table 2(Dimensions of Rectangular Loft Tanks) |
- |
0 |
|
Charges already taken in clause no. 5.1 Table 1 |
| 5.2 Table 2(Dimensions of Rectangular Loft Tanks) |
- |
0 |
|
Charges already taken in clause no. 5.1 Table 1 |
| 5.2 Table 2(Dimensions of Rectangular Loft Tanks) |
- |
0 |
|
Charges already taken in clause no. 5.1 Table 1 |
| 5.2 Table 2(Dimensions of Rectangular Loft Tanks) |
- |
0 |
|
Charges already taken in clause no. 5.1 Table 1 |
| 5.2 Table 2(Dimensions of Rectangular Loft Tanks) |
- |
0 |
|
Charges already taken in clause no. 5.1 Table 1 |
| 5.2 Table 2(Dimensions of Rectangular Loft Tanks) |
- |
0 |
|
Charges already taken in clause no. 5.1 Table 1 |
| 5.3(Types and Features ) |
- |
0 |
|
Charges already taken in clause no. 5.1 Table 1 |
| 5.6(Types and Features ) |
- |
0 |
|
Charges already taken in clause no. 5.1 Table 1 |
| 6.1(Finish) |
- |
300 |
|
Nil |
| 7.1.1(Resistance to Deformation) |
- |
700 |
|
Nil |
| 7.1.2(Resistance to Deformation) |
- |
0 |
|
Charges already taken in clause no. 7.1.1 |
| 7.2(Resistance to Impact) |
- |
1100 |
|
Nil |
| 7.3(Test for Top Load Resistance) |
- |
900 |
|
Nil |
| 7.4(Tensile Strength) |
- |
1350 |
|
Testing charges Rs.1100/- + specimen charges Rs.250/- |
| 7.5(Flexural Modulus) |
- |
1600 |
|
Testing charges Rs.1100/- plus specimen charges Rs.500/- (25% discount is not applicable in specimen charges) |
| 7.6(overall Migration) |
- |
2200 |
|
Testing charges Rs.1700/- + specimen charges Rs.500/- |
|
31 Dec, 2026 |
- - |
| 12856 |
CENTRAL INSTITUTE OF PETROCHEMICALS ENGINEERING AND TECHNOLOGY (CIPET):CSTS-BHOPAL
| 8100534
| IS 12585 (1988) |
Specification for thermoplastic hoses (Textile Reinforced) for water - General purpose |
- |
6500 View breakup
Rs.4875/-
(After 25% discount for BIS)
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl 3(Types) |
- |
0 |
|
Nil |
| Cl 4.1(Construction) |
- |
300 |
|
Nil |
| Cl 4.2(Dimensions & Tolerances) |
- |
500 |
|
Nil |
| Cl 4.3.1 & Appendix A(Loss in Mass on Heating) |
- |
700 |
|
Nil |
| Cl 4.3.2(Adhesion) |
- |
1100 |
|
Nil |
| Cl 4.3.3(Pressure Requirements) |
- |
1700 |
|
Nil |
| Cl 4.3.4(Minimum Bend Radius) |
- |
700 |
|
Nil |
| Cl 4.3.5(Low Temperature Flexibility) |
- |
1500 |
|
Nil |
|
31 Dec, 2026 |
- 0.0 |
| 12857 |
CENTRAL INSTITUTE OF PETROCHEMICALS ENGINEERING AND TECHNOLOGY (CIPET):CSTS-BHOPAL
| 8100534
| IS 12232 : Part 1 (1996) |
Irrigation equipment - Rotating sprinkler: Part 1 design and operational requirements (First Revision) |
- |
21200 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4.1(Materials) |
- |
1350 |
|
Nil |
| 4.1(Materials) |
- |
0 |
|
Charges already taken in clause no. 4.1 |
| 4.1(Materials) |
- |
0 |
|
Charges already taken in clause no. 4.1 |
| 4.2.1(Construction and workmanship) |
- |
300 |
|
Nil |
| 4.2.2(Construction and workmanship) |
- |
0 |
|
Charges already taken in clause no. 4.2.1 |
| 4.2.3(Construction and workmanship) |
- |
0 |
|
Charges already taken in clause no. 4.2.1 |
| 4.3(Threaded connections
ISO 7-1.) |
- |
400 |
|
Nil |
| 4.4.1(Effective pressures) |
- |
400 |
|
Nil |
| 4.4.2(Actuating mechanism) |
- |
400 |
|
Nil |
| 6.1(Test of construction and parts) |
- |
300 |
|
Nil |
| 6.2.1(Threaded connections to riser) |
- |
400 |
|
Nil |
| 6.2.2(Nozzle threads intended for threaded
connection) |
- |
400 |
|
Nil |
| 6.3(Test of resistance to hydrostatic pressure at ambient temperature) |
- |
850 |
|
Nil |
| 6.4(Test of resistance to hydrostatic
pressure at high temperature) |
- |
1600 |
|
Nil |
| 6.5.1 a(Watertightness of sprinkler - flowrate < 250 Iih) |
- |
400 |
|
Nil |
| 6.5.2(Watertightness of nozzle connection) |
- |
400 |
|
Nil |
| 7.1(Test of uniformity of rotation speed) |
- |
400 |
|
Nil |
| 7.2(Test of uniformity of ftowrate ) |
- |
400 |
|
Nil |
| 7.3(Test of distribution characteristics) |
- |
1900 |
|
Nil |
| 7.4(Test of effective diameter of coverage) |
- |
400 |
|
Nil |
| 7.5(Test of trajectory height (for sprinklers
with low trajectory angle)) |
- |
400 |
|
Nil |
| 7.6(Test of range of effective pressure) |
- |
400 |
|
Nil |
| 8.1 and 6.1(Durability tests) |
- |
6550 |
|
Nil |
| 8.2 and 6.3(Durability tests) |
- |
850 |
|
Nil |
| 8.3 and 6.5.1(Durability tests) |
- |
400 |
|
Nil |
| 8.4(Durability tests) |
- |
400 |
|
Nil |
| 8.5(Durability tests) |
- |
400 |
|
Nil |
| 8.6(Durability tests) |
- |
1500 |
|
Nil |
|
31 Dec, 2026 |
- - |
| 12858 |
Alpha Test House Services LLP (160), Sahibzada Ajit Singh Nagar
| 9138706
| IS 1786 (2008) |
High strength deformed steel bars and wires for concretere inforcement - Specification (Fourth Revision) |
fe415,415d,415s,500,500d,500s,550,550d,600 |
38500 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl 8.1(UTM) |
- |
1000 |
|
FOR BIS SAMPLES:15% DISCOUNT |
| Cl 9.3(Load In One Direction) |
- |
1000 |
|
FOR BIS SAMPLES:15% DISCOUNT |
| Cl 9.4(Load In Other Direction From Bend) |
- |
1000 |
|
FOR BIS SAMPLES:15% DISCOUNT |
| Cl 5(Deformations and Surface Characteristics) |
- |
6666.66 |
|
FOR BIS SAMPLES:15% DISCOUNT |
| Cl 6.1(Length, Width & Thickness) |
- |
0 |
|
FOR BIS SAMPLES:15% DISCOUNT |
| Cl 7.2(Weight) |
- |
0 |
|
FOR BIS SAMPLES:15% DISCOUNT |
| 4.1(Sulphur and phosphorous) |
- |
0 |
|
FOR BIS SAMPLES:15% DISCOUNT |
| 4.1(CE) |
- |
500 |
|
FOR BIS SAMPLES:15% DISCOUNT |
| 4.1( Nitrogen%) |
- |
2000 |
|
FOR BIS SAMPLES:15% DISCOUNT |
| 4.1(Ni) |
- |
500 |
|
FOR BIS SAMPLES:15% DISCOUNT |
| 4.1(Mo) |
- |
500 |
|
FOR BIS SAMPLES:15% DISCOUNT |
| 4.1(Cr) |
- |
500 |
|
FOR BIS SAMPLES:15% DISCOUNT |
| 4.1( Ti) |
- |
500 |
|
FOR BIS SAMPLES:15% DISCOUNT |
| 4.1(V) |
- |
500 |
|
FOR BIS SAMPLES:15% DISCOUNT |
| 4.1( Nb) |
- |
1000 |
|
FOR BIS SAMPLES:15% DISCOUNT |
| 4.1( Aluminium %) |
- |
500 |
|
FOR BIS SAMPLES:15% DISCOUNT |
| 4.1( Copper %) |
- |
500 |
|
FOR BIS SAMPLES:15% DISCOUNT |
| 4.1(Silicon %) |
- |
500 |
|
FOR BIS SAMPLES:15% DISCOUNT |
| 4.1(Sulphur %) |
- |
1000 |
|
FOR BIS SAMPLES:15% DISCOUNT |
| 4.1(Phosphorus %) |
- |
1000 |
|
FOR BIS SAMPLES:15% DISCOUNT |
| 4.1(Manganese %) |
- |
500 |
|
FOR BIS SAMPLES:15% DISCOUNT |
| 4.1(Carbon %) |
- |
1000 |
|
FOR BIS SAMPLES:15% DISCOUNT |
| Clause - 4.2 & 4.2.1(Fe- 415, Fe- 415D, Fe-500, Fe-500D, Fe-550, Fe-550D, Fe-600 CARBON +EQUIVELENT ) |
- |
500 |
|
FOR BIS SAMPLES:15% DISCOUNT |
| Clause - 4.2 & 4.2.1(Fe- 415, Fe- 415D, Fe-500, Fe-500D, Fe-550, Fe-550D, Fe-600 SULPHUR+PHOSPHUR) |
- |
0 |
|
FOR BIS SAMPLES:15% DISCOUNT |
| Clause - 4.2 & 4.2.1(Fe- 415, Fe- 415D, Fe-500, Fe-500D, Fe-550, Fe-550D, Fe-600 MANGANESE) |
- |
500 |
|
FOR BIS SAMPLES:15% DISCOUNT |
| Clause - 4.2 & 4.2.1(Fe- 415, Fe- 415D, Fe-500, Fe-500D, Fe-550, Fe-550D, Fe-600 NITROGEN) |
- |
2000 |
|
FOR BIS SAMPLES:15% DISCOUNT |
| Clause - 4.2 & 4.2.1(Fe- 415, Fe- 415D, Fe-500, Fe-500D, Fe-550, Fe-550D, Fe-600 PHOSPHURS) |
- |
1000 |
|
FOR BIS SAMPLES:15% DISCOUNT |
| Clause - 4.2 & 4.2.1(Fe- 415, Fe- 415D, Fe-500, Fe-500D, Fe-550, Fe-550D, Fe-600 SULPHUR) |
- |
1000 |
|
FOR BIS SAMPLES:15% DISCOUNT |
| Clause - 4.2 & 4.2.1(Fe- 415, Fe- 415D, Fe-500, Fe-500D, Fe-550, Fe-550D, Fe-600 CARBON ) |
- |
1000 |
|
FOR BIS SAMPLES:15% DISCOUNT |
| Cl.9.4 & Cl. 9.4.1(Rebend test) |
- |
1000 |
|
FOR BIS SAMPLES:15% DISCOUNT |
| Cl. 8.1 Table 3(Elongation, percentage) |
- |
1000 |
|
FOR BIS SAMPLES:15% DISCOUNT |
| Cl. 8.1 Table 3(TS/YS ratio) |
- |
0 |
|
FOR BIS SAMPLES:15% DISCOUNT |
| Cl. 8.1 Table 3(Tensile Strength (TS)) |
- |
1500 |
|
FOR BIS SAMPLES:15% DISCOUNT |
| Cl. 8.1 Table 3(Yield Stress (YS)) |
- |
1500 |
|
FOR BIS SAMPLES:15% DISCOUNT |
| Cl. 7.2 Table -2 (Nominal Mass) |
- |
0 |
|
FOR BIS SAMPLES:15% DISCOUNT |
| Cl. 6.1(Nominal Size) |
- |
0 |
|
FOR BIS SAMPLES:15% DISCOUNT |
| Cl. 5 (Cl. 5 - Mean projected area of transverse ribs (1/3 of Ar)) |
- |
6666.66 |
|
FOR BIS SAMPLES:15% DISCOUNT |
| Cl. 5 (Cl.5 Mean area of ribs/unit length (Ar), ) |
- |
6666.66 |
|
FOR BIS SAMPLES:15% DISCOUNT |
|
31 Dec, 2026 |
- - |
| 12859 |
Alpha Test House Services LLP (160), Sahibzada Ajit Singh Nagar
| 9138706
| IS 2830 (2012) |
Carbon steel cast billet ingots, billets, blooms and slabs for re-rolling into steel for general structural purposes - Specification (Third Revision) |
C15C18C20C15MMnC18MMnC20MMnC15HMnC18HMnC20HMnC25HMn |
23900 View breakup
Rs.5500/- for physical and chemical tests (25% discount to BIS), Rs.7900/- for Micro alloy elements, Rs.10000/- for optional test (25% discount to BIS)
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl 9(Workmanship) |
- |
500 |
|
FOR BIS SAMPLES-ADDITIONAL 25% DISCOUNT |
| Cl 10.1.a)(Workmanship) |
- |
5000 |
|
FOR BIS SAMPLES-ADDITIONAL 25% DISCOUNT |
| Cl 10.1.b)(Workmanship) |
- |
5000 |
|
FOR BIS SAMPLES-ADDITIONAL 25% DISCOUNT |
| Cl 10.2(Press) |
- |
800 |
|
FOR BIS SAMPLES-ADDITIONAL 25% DISCOUNT |
| Cl 10.3(Workmanship) |
- |
500 |
|
FOR BIS SAMPLES-ADDITIONAL 25% DISCOUNT |
| Cl 11(Length, Width & Thickness) |
- |
1000 |
|
FOR BIS SAMPLES-ADDITIONAL 25% DISCOUNT |
| 6.1(Carbon %) |
- |
800 |
|
FOR BIS SAMPLES-ADDITIONAL 25% DISCOUNT |
| 6.1(Manganese %) |
- |
800 |
|
FOR BIS SAMPLES-ADDITIONAL 25% DISCOUNT |
| 6.1(Phosphorus %) |
- |
800 |
|
FOR BIS SAMPLES-ADDITIONAL 25% DISCOUNT |
| 6.1(Sulphur %) |
- |
800 |
|
FOR BIS SAMPLES-ADDITIONAL 25% DISCOUNT |
| 6.1(Silicon %) |
- |
500 |
|
FOR BIS SAMPLES-ADDITIONAL 25% DISCOUNT |
| 6.1( Copper %) |
- |
800 |
|
FOR BIS SAMPLES-ADDITIONAL 25% DISCOUNT |
| 6.1( Aluminium %) |
- |
800 |
|
FOR BIS SAMPLES-ADDITIONAL 25% DISCOUNT |
| 6.1( Nb) |
- |
800 |
|
FOR BIS SAMPLES-ADDITIONAL 25% DISCOUNT |
| 6.1(V) |
- |
500 |
|
FOR BIS SAMPLES-ADDITIONAL 25% DISCOUNT |
| 6.1( Ti) |
- |
500 |
|
FOR BIS SAMPLES-ADDITIONAL 25% DISCOUNT |
| 6.1(Cr) |
- |
500 |
|
FOR BIS SAMPLES-ADDITIONAL 25% DISCOUNT |
| 6.1(Mo) |
- |
500 |
|
FOR BIS SAMPLES-ADDITIONAL 25% DISCOUNT |
| 6.1(Ni) |
- |
500 |
|
FOR BIS SAMPLES-ADDITIONAL 25% DISCOUNT |
| 6.1( Nitrogen%) |
- |
2000 |
|
FOR BIS SAMPLES-ADDITIONAL 25% DISCOUNT |
|
31 Dec, 2026 |
- - |
| 12860 |
Envirocare Labs Pvt Ltd, Thane
| 7120616
| IS 1166 (1986) |
Specification for condensed milk, partly skimmed and skimmed condensed milk (Second Revision) |
Condensed,Partially skimmed condensed,skimmed condensed |
4400 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Table 1 (i) (Apendix B)(Total milk solids - Skirmned Condensed Milk) |
- |
400 |
|
NA |
| Table 1 (ii) (IS : 11762-
1986)(Fat -Skirmned Condensed Milk) |
- |
400 |
|
NA |
| Table 1 (iii) (Apendix C)(Sucrose -Skirmned Condensed Milk) |
- |
550 |
|
NA |
| Table 1 (vi) (Apendix D)(Titratable acidity (as lactic acid) -Condensed Milk) |
- |
400 |
|
NA |
| Cl.5.1.10.2(Coliform Count IS 5401 Part 1) |
- |
400 |
|
NA |
| Cl.5.1.10.3(Yeast and Mould Count IS 5403) |
- |
550 |
|
NA |
| Cl.5.1.10.4(Coagulase positive Staphylococcus aureus IS 5887 Part 2) |
- |
400 |
|
NA |
| Clause no 4.1.10.2(coliform count) |
- |
400 |
|
- |
| Clause no 4.1.10.3(Yeast & Mould count) |
- |
550 |
|
- |
| Clause no 4.1.10.4(S.aureus) |
- |
400 |
|
- |
| Table 1 (v) (Apendix E)(Accelerated starage test -Condensed Milk) |
- |
500 |
|
- |
| Table 1 (v) (Apendix E)(Accelerated starage test -Partly Skimmed Condenied Milk) |
- |
500 |
|
- |
| Table 1 (v) (Apendix E)(Accelerated starage test -Skirmned Condensed Milk) |
- |
500 |
|
- |
| 4.1.4(Colour) |
- |
100 |
|
- |
| 4.1.5(Flavour and Taste) |
- |
100 |
|
- |
| 4.1.8(size of lactose crystals) |
- |
200 |
|
- |
| 4.1.10.2(Bacteria count) |
- |
400 |
|
- |
|
25 May, 2027 |
- - |
| 12861 |
CENTRAL INSTITUTE OF PETROCHEMICALS ENGINEERING AND TECHNOLOGY (CIPET):CSTS-BHOPAL
| 8100534
| IS 15351 (2015) |
Agro textiles – Laminated high density polyethylene (HDPE) woven geomembrane for water proof lining – Specification (second revision) |
- |
196400 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 3.1(HDPE Tapes) |
- |
2050 |
|
Nil |
| 3.2(HDPE Fabric) |
- |
1975 |
|
Nil |
| 5(MANUFACTURE) |
- |
300 |
|
Nil |
| 5.1(Lamination) |
- |
1050 |
|
Nil |
| 5.2(Panel Width) |
- |
250 |
|
Nil |
| 5.3(Joints/Seams) |
- |
200 |
|
Nil |
| 5.1.1 and 6.2(Thickness, mm- IS 7016: Part 1) |
- |
250 |
|
Nil |
| 5.1.1 and 6.2(Mass, g/sq m) |
- |
250 |
|
Nil |
| 5.1.1 and 6.2(Dimensions, mm- Annexure A of IS 11652) |
- |
250 |
|
Nil |
| 5.1.1 and 6.2(Length) |
- |
0 |
|
Charges already taken in dimension |
| 5.1.1 and 6.2(Width) |
- |
0 |
|
Charges already taken in dimension |
| 5.1.1 and 6.2(Carbon black content, Percent- IS 2530) |
- |
925 |
|
Nil |
| 5.1.1 and 6.2(Breaking Load on 20 cm X 10 cm Strip, Min ) |
- |
1100 |
|
Nil |
| 5.1.1 and 6.2(Before UV exposure IS 13162 (Part 5) |
- |
1100 |
|
Nil |
| 5.1.1 and 6.2(Strain at Maximum load, Percent-IS 13162 (Part 5) |
- |
1100 |
|
Nil |
| Table-1(Breaking load on 20 × 10 cm strip, N, Min after) |
- |
1100 |
|
Nil |
| 5.1.1 and 6.2( U.V exposure of 1000 h for warp and weft) |
- |
176000 |
|
Rs. 176000/- conditioning charges (25% discount is not applicable in conditioning charges) |
| 5.1.1 and 6.2(Impact failure load, at 1524 mm drop,) |
- |
1100 |
|
Nil |
| 5.1.1 and 6.2( Min, gram force at 50 percent failure-Annex C) |
- |
1100 |
|
Nil |
| 5.1.1 and 6.2(Tear resistance, N, Min-Method A1 of
IS 7016 (Part 3)) |
- |
1100 |
|
Nil |
| 5.1.1 and 6.2(Puncture resistance, N, Min-Annex D) |
- |
1100 |
|
Nil |
| 5.1.1 and 6.2(Bursting strength (Ball burst),N/cm², Min-) |
- |
1000 |
|
Nil |
| 5.1.1 and 6.2(IS 7016 (Part 6)) |
- |
1100 |
|
Nil |
| 5.1.1 and 6.2(Seam strength before UV exposure (N/mm), Min-IS 15060) |
- |
1100 |
|
Nil |
| Table-1(Seam strength after UV exposure N/mm, Min-Annex B and
IS 15060) |
- |
1100 |
|
Nil |
| 5.1.1 and 6.2(Hydrostatic resistance-Annex E) |
- |
2000 |
|
Nil |
| 5.1.1 and 6.2(Ash content, percent, Max-Annex F) |
- |
950 |
|
Nil |
|
31 Dec, 2026 |
- - |
| 12862 |
Envirocare Labs Pvt Ltd, Thane
| 7120616
| IS 1155 (1968) |
Specification for wheat aita (Second Revision) |
Low Gluten (LG) High Gluten (HG) |
3650 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Table 1 (i), Annex A(Moisture LG) |
- |
300 |
|
NA |
| Table 1 (ii), Annex B(Total Ash (on dry basis) LG) |
- |
400 |
|
NA |
| Table 1 (iii), Annex C(Add insoluble Ash (on dry basis) LG) |
- |
650 |
|
NA |
| Table 1 (iv), Annex D(Glutin (on dry basis) LG) |
- |
750 |
|
NA |
| Table 1 (v), Annex E(Crude Fibre (on dry basis) LG) |
- |
750 |
|
NA |
| Table 1 (vi), Annex F(Alcoholic acidity (As H2SO4.), with 90 prcent Alcohol (on dry basis) LG) |
- |
400 |
|
NA |
| Table 1 (vii), Annex G(Granularity(on dry basis) LG) |
- |
200 |
|
NA |
| CL 3.1(Decription) |
- |
100 |
|
- |
| CL 3.2(Microscopic Appearance) |
- |
100 |
|
- |
|
25 May, 2027 |
- - |
| 12863 |
Alpha Test House Services LLP (160), Sahibzada Ajit Singh Nagar
| 9138706
| IS 2831 (2012) |
Carbon steel cast billet ingots, billets, blooms and slabs for re-rolling into structural steel (Ordinary Quality) - Specification (Fourth Revision) |
C8;C15;C22 |
23400 View breakup
Rs.5500/- for physical and chemical tests (25% discount to BIS), Rs.7900/- for Micro alloy elements, Rs.10000/- for optional test (25% discount to BIS)
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl. 6.1, Table 1(Carbon- IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
800 |
|
FOR BIS SAMPLES-ADDITIONAL 25%DISCOUNT
GST WILL BE CHARGED EXTRA @18% |
| Cl. 6.1, Table 1(Manganese- IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
800 |
|
FOR BIS SAMPLES-ADDITIONAL 25%DISCOUNT
GST WILL BE CHARGED EXTRA @18% |
| Cl. 6.1, Table 1(Sulphur- IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
800 |
|
FOR BIS SAMPLES-ADDITIONAL 25%DISCOUNT
GST WILL BE CHARGED EXTRA @18% |
| Cl. 6.1, Table 1(Phosphorus- IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
800 |
|
FOR BIS SAMPLES-ADDITIONAL 25%DISCOUNT
GST WILL BE CHARGED EXTRA @18% |
| Cl. 6.1, Table 1(Silicon- IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
500 |
|
FOR BIS SAMPLES-ADDITIONAL 25%DISCOUNT
GST WILL BE CHARGED EXTRA @18% |
| Cl. 6.1, Table 1(Aluminium- IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
800 |
|
FOR BIS SAMPLES-ADDITIONAL 25%DISCOUNT
GST WILL BE CHARGED EXTRA @18% |
| Cl. 6.1, Table 1(Nitrogen- IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
2000 |
|
FOR BIS SAMPLES-ADDITIONAL 25%DISCOUNT
GST WILL BE CHARGED EXTRA @18% |
| Cl. 6.1, Table 1(Copper- IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
800 |
|
FOR BIS SAMPLES-ADDITIONAL 25%DISCOUNT
GST WILL BE CHARGED EXTRA @18% |
| Cl. 6.1, Table 1(Niobium- IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
800 |
|
FOR BIS SAMPLES-ADDITIONAL 25%DISCOUNT
GST WILL BE CHARGED EXTRA @18% |
| Cl. 6.1, Table 1(Vanadium- IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
500 |
|
FOR BIS SAMPLES-ADDITIONAL 25%DISCOUNT
GST WILL BE CHARGED EXTRA @18% |
| Cl. 6.1, Table 1(Titanium- IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
500 |
|
FOR BIS SAMPLES-ADDITIONAL 25%DISCOUNT
GST WILL BE CHARGED EXTRA @18% |
| 9( FREEDOM FROM DEFECTS) |
- |
500 |
|
FOR BIS SAMPLES-ADDITIONAL 25%DISCOUNT
GST WILL BE CHARGED EXTRA @18% |
| 10.1.a)( Macro examination IS 11371) |
- |
5000 |
|
FOR BIS SAMPLES-ADDITIONAL 25%DISCOUNT
GST WILL BE CHARGED EXTRA @18% |
| 10.1.b)( Sulphur print tests IS 12037) |
- |
5000 |
|
FOR BIS SAMPLES-ADDITIONAL 25%DISCOUNT
GST WILL BE CHARGED EXTRA @18% |
| 11 & 12(DIMENSIONS and Tolerances) |
- |
1000 |
|
FOR BIS SAMPLES-ADDITIONAL 25%DISCOUNT
GST WILL BE CHARGED EXTRA @18% |
|
31 Dec, 2026 |
- - |
| 12864 |
Envirocare Labs Pvt Ltd, Thane
| 7120616
| IS 1011 (2002) |
Biscuits - Specification (Fourth Revision) |
Type I,Type II,Type III,Type IV,Type V |
1800 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 6.1(General Requirement) |
- |
200 |
|
NA |
| 6.3 Table 2 i (Moisture) |
- |
300 |
|
NA |
| 6.3 Table 2 ii (Acid insoluble ash (on dry basis)) |
- |
650 |
|
NA |
| 6.3 Table 2 iii (Acidity of extracted fat (as oleic acid)) |
- |
650 |
|
NA |
|
25 May, 2027 |
- - |
| 12865 |
CENTRAL INSTITUTE OF PETROCHEMICALS ENGINEERING AND TECHNOLOGY (CIPET):CSTS-BHOPAL
| 8100534
| IS 16208 (2015) |
Textiles - High density polyethylene (HDPE)/polypropylene (PP) woven sacks for packaging 10 kg, 15 kg, 20 kg, 25 kg and 30 kg foodgrains - Specification |
- |
20580 View breakup
Rs.17155/-
(After 25% discount for BIS)
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 3(TYPES) |
- |
300 |
|
Nil |
| 4.1(Raw Material) |
- |
1050 |
|
Nil |
| 4.2(Tapes – Width
IS 6192 and IS 11197) |
- |
250 |
|
Nil |
| 4.2(Tapes – Linear Density
) |
- |
500 |
|
Nil |
| 4.2(Construction) |
- |
250 |
|
Nil |
| 4.3(Sacks) |
- |
300 |
|
Nil |
| 4.3.1(Bottom Seam) |
- |
0 |
|
Charges already taken in clause no. 4.3 |
| 4.3.1( The two rows of stitches shall be separated from each other) |
- |
0 |
|
Charges already taken in clause no. 4.3 |
| 4.3.1( The outer stitch) |
- |
0 |
|
Charges already taken in clause no. 4.3 |
| 4.3.1( The stitching shall be done with double fold over seam to a depth ) |
- |
0 |
|
Charges already taken in clause no. 4.3 |
| 4.3.1(Stitches pass through a minimum of six layers of the fabric. ) |
- |
0 |
|
Charges already taken in clause no. 4.3 |
| 4.3.1(The number of stitches/dm) |
- |
0 |
|
Charges already taken in clause no. 4.3 |
| 4.3.2(Mouth) |
- |
0 |
|
Charges already taken in clause no. 4.3 |
| 4.4 and Table 1 i(Capacity) |
- |
250 |
|
Nil |
| 5.2 and Table 1 ii a(Dimensions Inside Length) |
- |
250 |
|
Nil |
| 5.2 and Table 1 ii b(Dimensions Inside Width) |
- |
0 |
|
Charges already taken in clause no. 5.2 |
| 5.2 and Table 1 iii(Ends per dm ) |
- |
250 |
|
Nil |
| 5.2 and Table 1 iv(Picks per dm ) |
- |
250 |
|
Nil |
| 5.1 and Table 1 v(Mass of sack ) |
- |
300 |
|
Nil |
| 5.2 and Table 1 vi a(Average breaking strength of fabric Lengthwise ) |
- |
1100 |
|
Nil |
| 5.2 and Table 1 vi b(Average breaking strength of fabric Widthwise ) |
- |
1100 |
|
Nil |
| 5.2 and Table 1 vi(Breaking strength of bottom seam ) |
- |
1100 |
|
Nil |
| 5.2 and Table 1 viii a(Elongation at break of fabric Lengthwise) |
- |
1100 |
|
Nil |
| 5.2 and Table 1 viii b(Elongation at break of fabric Widthwise ) |
- |
1100 |
|
Nil |
| 5.2 and Table 1 ix(Average breaking strength and elongation at break of UV stabilized HDPE/PP fabric after been exposed to UV radiation and weathering ) |
- |
10180 |
|
Rs. 10180/- Conditioning charges (25% discount is not applicable) |
| 5.2 and Table 1 x(Ash content ) |
- |
950 |
|
Nil |
|
31 Dec, 2026 |
- Included w.e.f. 29.06.2017. |
| 12866 |
CENTRAL INSTITUTE OF PETROCHEMICALS ENGINEERING AND TECHNOLOGY (CIPET):CSTS-BHOPAL
| 8100534
| IS 9537 : Part 4 (1983) |
Specification for conduits for electrical installations: Part 4 pliable self - Recovering conduits of insulating materials |
- |
9700 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 6.1(Marking, IS 9537-4) |
- |
300 |
|
Nil |
| 6.1(Marking, IS 9537-4) |
- |
0 |
|
Nil |
| 6.1(Marking, IS 9537-4) |
- |
0 |
|
Nil |
| 6.1(Marking, IS 9537-4) |
- |
0 |
|
Nil |
| 6.2(Marking, IS 9537-4) |
- |
0 |
|
Nil |
| 6.2.1(Marking, IS 9537-4) |
- |
0 |
|
Nil |
| 6.3(Marking, Cl. 6.4 of IS 9537-1) |
- |
0 |
|
Nil |
| 7.1(Dimensions, (Minimum outside Diameter), IS 9537-4) |
- |
1000 |
|
Nil |
| 7.1(Dimensions (Maximum outside Diameter), IS 9537-4) |
- |
0 |
|
Charges already taken in clause no. 7.1 |
| 7.3.3(Uniformity of wall thickness, IS 9537-4) |
- |
0 |
|
Charges already taken in clause no. 7.1 |
| 9.2(Mechanical Properties (Bending test), Cl. 9.3 of IS 9537-1) |
- |
500 |
|
Nil |
| 9.2(Mechanical Properties (Bending test), Cl. 9.3 of IS 9537-1) |
- |
500 |
|
Nil |
| 9.3(Mechanical Properties (Compression Test), IS 9537-4) |
- |
1100 |
|
Nil |
| 9.4(Mechanical Properties (Impact Test), Cl. 9.4 of IS 9537-1) |
- |
1100 |
|
Nil |
| 9.5(Mechanical Properties (Collapse Test), IS 9537-4) |
- |
1000 |
|
Nil |
| 10(Resistance to heat) |
- |
700 |
|
Nil |
| 11(Resistance to burning, Cl. 11 of IS 9537-1) |
- |
700 |
|
Nil |
| 12(Electrical Strength, Cl. 12.1.1 of IS 9537-1) |
- |
1400 |
|
Test charges Rs. 1100/- Plus specimen charges Rs. 300/- (25 % discount is not applicable in specimen charges) |
| 12(Insulation Resistance, Cl. 12.1.2 of IS 9537-1) |
- |
1400 |
|
Test charges Rs. 1100/- Plus specimen charges Rs. 300/- (25 % discount is not applicable in specimen charges) |
|
31 Dec, 2026 |
- - |
| 12867 |
CENTRAL INSTITUTE OF PETROCHEMICALS ENGINEERING AND TECHNOLOGY (CIPET):CSTS-BHOPAL
| 8100534
| IS 9537 : Part 3 (1983) |
Specification for conduits for electrical installations: Part 3 rigid plain conduits of insulating meterials |
- |
9700 View breakup
Rs.7425/-
(After 25% discount for BIS)
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 6.1(Marking) |
- |
0 |
|
Nil |
| 6.2(Durability of Marking as per 6.4 of IS: 9537 (Part 1)-1980) |
- |
0 |
|
Nil |
| 6.3(Standard Mark on Conduit) |
- |
0 |
|
Nil |
| 7.1.1(Maximum and minimum outside diameter of socket) |
- |
1000 |
|
Nil |
| 7.1.1 Table-2(Length of Socket end) |
- |
0 |
|
Charges already taken in clause no. 7.1.1 |
| 7.1.2(Maximum and minimum outside diameter of conduit) |
- |
0 |
|
Charges already taken in clause no. 7.1.1 |
| 7.2(Minimum inside diameter of conduit) |
- |
0 |
|
Charges already taken in clause no. 7.1.1 |
| 7.3(Length of conduit) |
- |
0 |
|
Charges already taken in clause no. 7.1.1 |
| 7.4(Unifomity of The wall Thickness) |
- |
0 |
|
Charges already taken in clause no. 7.1.1 |
| 8.1(Construction as per clause 8 of IS: 9537 (Part 1)-1980) |
- |
300 |
|
Nil |
| 9.2(Bending Test i) At Room Temp ii) At Low Temp (-5 ±2°C)) |
- |
1000 |
|
Nil |
| 9.3(Compression Test as per caluse 9.3 of IS: 9537 (Part 1)-1980) |
- |
1100 |
|
Nil |
| 9.4(Impact Test as per clause 9.4 of IS: 9537 (Part 1)-1980) |
- |
1100 |
|
Nil |
| 9.5(Collapse Test as per clause 9.5 of IS: 9537 (Part 1)-1980) |
- |
1000 |
|
Nil |
| 10(Resistance to Heat -Ball presure test) |
- |
700 |
|
Nil |
| 11(Resistance to burning as per clause 11 of IS: 9537 (Part 1)-1980) |
- |
700 |
|
Nil |
| 12(Electrical Characteristics-Test for electric strength as per clause 12.1.1 of IS: 9537 (Part 1)-1980) |
- |
1400 |
|
Test Charges Rs. 1100/- plus specimen charges Rs. 300/- (25% discount is not applicable in specimen charges) |
| 13(Tests for external influence as per clause 13 of IS: 9537 (Part 1)-1980) |
- |
1400 |
|
Test Charges Rs. 1100/- plus specimen charges Rs. 300/- (25% discount is not applicable in specimen charges) |
|
31 Dec, 2026 |
- 0.0 |
| 12868 |
CENTRAL INSTITUTE OF PETROCHEMICALS ENGINEERING AND TECHNOLOGY (CIPET):CSTS-BHOPAL
| 8100534
| IS 9537 : Part 2 (1981) |
Specification for conduits for electrical installations: Part 2 rigid steel conduits |
- |
4500 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 6.1(Marking, IS 9537-2) |
- |
0 |
|
Nil |
| 6.1(Marking, IS 9537-2) |
- |
0 |
|
Nil |
| 6.1(Marking, IS 9537-2) |
- |
0 |
|
Nil |
| 6.3(Marking, Cl. 6.4 of IS 9537-1) |
- |
0 |
|
Nil |
| 6.2(Marking, IS 9537-2) |
- |
0 |
|
Nil |
| 7.2.1(Dimensions, (Minimum outside Diameter), IS 9537-2) |
- |
1000 |
|
Nil |
| 7.2.2(Dimensions (Maximum outside Diameter), IS 9537-2) |
- |
0 |
|
Charges already taken in clause no. 7.2.1 |
| 7.3(Dimensions (Wall thickness), IS 9537-2) |
- |
0 |
|
Charges already taken in clause no. 7.2.1 |
| 7.3.3(Uniformity of wall thickness, IS 9537-2) |
- |
0 |
|
Charges already taken in clause no. 7.2.1 |
| 8.1(Construction, Cl. 8 of IS 9537-1) |
- |
300 |
|
Nil |
| 8.2(Construction, IS 9537-2) |
- |
0 |
|
Charges already taken in clause no. 8.1 |
| 9.2(Mechanical Properties (Bending test), Cl. 9.3 of IS 9537-1) |
- |
1000 |
|
Nil |
| 9.3(Mechanical Properties (Compression Test), IS 9537-2) |
- |
1100 |
|
Nil |
| 13(External Influences, IS 9537-2) |
- |
1100 |
|
Nil |
|
31 Dec, 2026 |
- - |
| 12869 |
CENTRAL INSTITUTE OF PETROCHEMICALS ENGINEERING AND TECHNOLOGY (CIPET):CSTS-BHOPAL
| 8100534
| IS 8521 : Part 1 (1977) |
Specification for industrial safety face shields: Part 1 with plastics visor |
- |
9450 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl 3(General requirements & Specific requirements) |
- |
250 |
|
Nil |
| Cl 4(Visual and Dimensional Examination & Physical Requirements (Impact Resistance, Penetration Resistance, Visible Transmittance, Flammability & Disinfection)) |
- |
9200 |
|
Testing charges Rs. 8950/- plus specimen charges 250/- (25 % discount is not applicable in specimen charges) |
|
31 Dec, 2026 |
- Included w.e.f. 27-05-2022. |
| 12870 |
CENTRAL INSTITUTE OF PETROCHEMICALS ENGINEERING AND TECHNOLOGY (CIPET):CSTS-BHOPAL
| 8100534
| IS 4985 (2021) |
UNPLASTICIZED PVC PIPES FOR POTABLE WATER SUPPLIES SPECIFICATION Fourth Revision |
- |
31925 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 5(CLASSIFICATION OF PIPES) |
- |
0 |
|
Nil |
| 7(DIMENSIONS-PIPE-Nominal Diameter) |
- |
500 |
|
- |
| 7.1.1.1(DIMENSIONS-PIPE-Mean O.D. (Minimum)) |
- |
0 |
|
Charges already had taken in clause no. 7 |
| 7.1.1.1(DIMENSIONS-PIPE-Mean O.D. (Mamimum)) |
- |
0 |
|
Charges already had taken in clause no. 7 |
| 7.1.1.1(DIMENSIONS-PIPE-Mean O.D. Variation) |
- |
0 |
|
Charges already had taken in clause no. 7 |
| 7.1.1.2(DIMENSIONS-PIPE-O.D. at any Point (Minimum)) |
- |
0 |
|
Charges already had taken in clause no. 7 |
| 7.1.1.2(DIMENSIONS-PIPE-O.D. at any Point (Maximum)) |
- |
0 |
|
Charges already had taken in clause no. 7 |
| 7.1.1.2(DIMENSIONS-PIPE-Ovality (Maximum)) |
- |
0 |
|
Charges already had taken in clause no. 7 |
| 7.1.2.1(DIMENSIONS-PIPE-Thickness(Minimum)) |
- |
0 |
|
Charges already had taken in clause no. 7 |
| 7.1.2.1(DIMENSIONS-PIPE-Thickness(Maximum)) |
- |
0 |
|
Charges already had taken in clause no. 7 |
| 7.1.2.1(DIMENSIONS-PIPE-Average Thickness) |
- |
0 |
|
Charges already had taken in clause no. 7 |
| 7.2.1(DIMENSIONS-Socket) |
- |
0 |
|
Charges already had taken in clause no. 7 |
| 7.2.1(DIMENSIONS-Socket) |
- |
0 |
|
Charges already had taken in clause no. 7 |
| 7.2.1.1-Table 3(DIMENSIONS-Socket-Sockets for solvent cement jointing-Minimum Length) |
- |
0 |
|
Charges already had taken in clause no. 7 |
| 7.2.1.1-Table 3(DIMENSIONS-Socket-Sockets for solvent cement jointing-Diameter at mid point of the socket length (Minimum)) |
- |
0 |
|
Charges already had taken in clause no. 7 |
| 7.2.1.1-Table 3(DIMENSIONS-Socket-Sockets for solvent cement jointing-Diameter at mid point of the socket length (Maximum)) |
- |
0 |
|
Charges already had taken in clause no. 7 |
| 7.2.1.2(a)-Table 5(DIMENSIONS-Sockets for elastomeric sealing ring joints-Minimum depth of engagement) |
- |
0 |
|
Charges already had taken in clause no. 7 |
| 7.2.1.2-Table 4(DIMENSIONS-Sockets for elastomeric sealing ring joints-Socket inner Diameter) |
- |
0 |
|
Charges already had taken in clause no. 7 |
| 8(SEALING RINGS) |
- |
0 |
|
- |
| 9.1(PIPE ENDS) |
- |
0 |
|
- |
| 9.1(PIPE ENDS) |
- |
0 |
|
Charges already taken in clause no. 7 |
| 10.1(PHYSICAL AND CHEMICAL CHARACTERISTICS-Visual Appearance) |
- |
300 |
|
Nil |
| 10.1.1(PHYSICAL AND CHEMICAL CHARACTERISTICS-Visual Appearance) |
- |
0 |
|
Charges already had taken in clause no. 10.1 |
| 10.2(PHYSICAL AND CHEMICAL CHARACTERISTICS-Opacity) |
- |
575 |
|
Nil |
| 10.4(PHYSICAL AND CHEMICAL CHARACTERISTICS- Reversion Test) |
- |
900 |
|
Test Charges Rs. 700/- plus Rs. 250 specimen charges (25% discount is not applicable in specimen charges) |
| 10.5(PHYSICAL AND CHEMICAL CHARACTERISTICS- Vicat Softening Temperature) |
- |
1100 |
|
Nil |
| 10.6(PHYSICAL AND CHEMICAL CHARACTERISTICS- Density) |
- |
500 |
|
Nil |
| 11.1-Table 6(MECHANICAL PROPERTIES-Hydrostatic Pressure Test (Type Test)) |
- |
11000 |
|
Nil |
| 11.1-Table 6(MECHANICAL PROPERTIES-Hydrostatic Pressure Test (Acceptance Test)) |
- |
850 |
|
Nil |
| 11.1-Table 7(MECHANICAL PROPERTIES-Hydrostatic Pressure Test (Type Test)-for Integral Sealing Ring
Sockets) |
- |
5000 |
|
Nil |
| 11.1-Table 7(MECHANICAL PROPERTIES-Hydrostatic Pressure Test (Acceptance Test)-for Integral Sealing Ring
Sockets) |
- |
850 |
|
Nil |
| 11.1.1(MECHANICAL PROPERTIES-Hydrostatic Pressure Test (Acceptance Test)-for Plumbing pipes) |
- |
0 |
|
Nil |
| 11.2(Resistance to External Blows at 0°C) |
- |
1300 |
|
Nil |
| Clause 10.7(Sulphated Ash Content) |
- |
950 |
|
Nil |
| 10.1(Colour) |
- |
0 |
|
- |
| 10.1(Surface Finish) |
- |
0 |
|
nil |
| 7.2.1.1 Table3(Angle of taper (Note-1)) |
- |
0 |
|
- |
| 10.7(Sulphated Ash Content) |
- |
0 |
|
The charges had already taken in the No. Clause 10.7 |
| 5(CLASSIFICATION OF PIPES) |
- |
0 |
|
- |
| Cl-7.1(Mean out side Diameter (For less than or equal to 40 mm- Average of 8 , For higher diameters up to 110 mm average of 6)) |
- |
0 |
|
- |
| 7.1.1.1(DIMENSIONS-PIPE-Mean O.D. (Minimum)) |
- |
0 |
|
- |
| 7.1.1.1(DIMENSIONS-PIPE-Mean O.D. Variation) |
- |
0 |
|
- |
| 7.1.1.2(DIMENSIONS-PIPE-O.D. at any Point (Minimum)) |
- |
0 |
|
- |
| 7.1.1.2(DIMENSIONS-PIPE-Ovality (Maximum)) |
- |
0 |
|
- |
| 7.1.2.1(DIMENSIONS-PIPE-Thickness(Minimum)) |
- |
0 |
|
- |
| 7.1.2.1(DIMENSIONS-PIPE-Thickness(Maximum)) |
- |
0 |
|
- |
| 7.1.2.1(DIMENSIONS-PIPE-Average Thickness) |
- |
0 |
|
- |
| Cl- 7.2(Socket length (Take 4 reading & minimum will be reported)) |
- |
0 |
|
- |
| 7.2.1.1-Table 3(DIMENSIONS-Socket-Sockets for solvent cement jointing-Minimum Length) |
- |
0 |
|
- |
| 7.2.1.1-Table 3(DIMENSIONS-Socket-Sockets for solvent cement jointing-Diameter at mid point of the socket length (Minimum)) |
- |
0 |
|
- |
| 7.2.1.1-Table 3(DIMENSIONS-Socket-Sockets for solvent cement jointing-Diameter at mid point of the socket length (Maximum)) |
- |
0 |
|
- |
| 7.2.1.2(a)-Table 5(DIMENSIONS-Sockets for elastomeric sealing ring joints-Minimum depth of engagement) |
- |
0 |
|
- |
| 7.2.1.2-Table 4(DIMENSIONS-Sockets for elastomeric sealing ring joints-Socket inner Diameter) |
- |
0 |
|
- |
| 8(SEALING RINGS) |
- |
0 |
|
The charges had taken already in clause no. 08. |
| 10.1(PHYSICAL AND CHEMICAL CHARACTERISTICS-Visual Appearance) |
- |
0 |
|
- |
| 10.2(PHYSICAL AND CHEMICAL CHARACTERISTICS-Opacity) |
- |
0 |
|
The charges had already taken in the clause no. 10.2 |
| 10.4(PHYSICAL AND CHEMICAL CHARACTERISTICS- Reversion Test) |
- |
0 |
|
The charges had already taken in the clause No. 10.4 |
| 10.5(PHYSICAL AND CHEMICAL CHARACTERISTICS- Vicat Softening Temperature) |
- |
0 |
|
The charges had already taken in the clause No. 10.5 |
| 10.6(PHYSICAL AND CHEMICAL CHARACTERISTICS- Density) |
- |
0 |
|
The charges had already taken in the clause No. 10.6 |
| 11.1-Table 6(MECHANICAL PROPERTIES-Hydrostatic Pressure Test (Type Test)) |
- |
0 |
|
- |
| 11.1-Table 6(MECHANICAL PROPERTIES-Hydrostatic Pressure Test (Acceptance Test)) |
- |
0 |
|
- |
| 11.1-Table 7(MECHANICAL PROPERTIES-Hydrostatic Pressure Test (Type Test)-for Integral Sealing Ring Sockets) |
- |
0 |
|
- |
| 11.1-Table 7(MECHANICAL PROPERTIES-Hydrostatic Pressure Test (Acceptance Test)-for Integral Sealing Ring Sockets) |
- |
0 |
|
- |
| 11.1.1(MECHANICAL PROPERTIES-Hydrostatic Pressure Test (Acceptance Test)-for Plumbing pipes) |
- |
0 |
|
- |
| 11.2(Resistance to External Blows at 0°C) |
- |
0 |
|
- |
| 10.3(Effect on Water Test) |
- |
3000 |
|
- |
| 6.1.2(PVC Resin) |
- |
4100 |
|
K value+ VCM content |
| 15.4 (b)(Cold impact) |
- |
0 |
|
- |
| 9.1(PIPE ENDS) |
- |
0 |
|
- |
| 10.1(Colour) |
- |
0 |
|
- |
| 10.1(Surface Finish) |
- |
0 |
|
- |
| 7.2.1.1 Table3(Angle of taper (Note-1)) |
- |
0 |
|
- |
| 10.7(Sulphated Ash Content) |
- |
0 |
|
- |
| 5(CLASSIFICATION OF PIPES) |
- |
0 |
|
- |
| Cl-7.1(Mean out side Diameter (For less than or equal to 40 mm- Average of 8 , For higher diameters up to 110 mm average of 6)) |
- |
0 |
|
- |
| 7.1.1.1(DIMENSIONS-PIPE-Mean O.D. (Minimum)) |
- |
0 |
|
- |
| 7.1.1.1(DIMENSIONS-PIPE-Mean O.D. Variation) |
- |
0 |
|
- |
| 7.1.1.2(DIMENSIONS-PIPE-O.D. at any Point (Minimum)) |
- |
0 |
|
- |
| 7.1.1.2(DIMENSIONS-PIPE-Ovality (Maximum)) |
- |
0 |
|
- |
| 7.1.2.1(DIMENSIONS-PIPE-Thickness(Minimum)) |
- |
0 |
|
- |
| 7.1.2.1(DIMENSIONS-PIPE-Thickness(Maximum)) |
- |
0 |
|
- |
| 7.1.2.1(DIMENSIONS-PIPE-Average Thickness) |
- |
0 |
|
- |
| Cl- 7.2(Socket length (Take 4 reading & minimum will be reported)) |
- |
0 |
|
- |
| 7.2.1.1-Table 3(DIMENSIONS-Socket-Sockets for solvent cement jointing-Minimum Length) |
- |
0 |
|
- |
| 7.2.1.1-Table 3(DIMENSIONS-Socket-Sockets for solvent cement jointing-Diameter at mid point of the socket length (Minimum)) |
- |
0 |
|
- |
| 7.2.1.1-Table 3(DIMENSIONS-Socket-Sockets for solvent cement jointing-Diameter at mid point of the socket length (Maximum)) |
- |
0 |
|
- |
| 7.2.1.2(a)-Table 5(DIMENSIONS-Sockets for elastomeric sealing ring joints-Minimum depth of engagement) |
- |
0 |
|
- |
| 7.2.1.2-Table 4(DIMENSIONS-Sockets for elastomeric sealing ring joints-Socket inner Diameter) |
- |
0 |
|
- |
| 8(SEALING RINGS) |
- |
0 |
|
- |
| 10.1(PHYSICAL AND CHEMICAL CHARACTERISTICS-Visual Appearance) |
- |
0 |
|
- |
| 10.2(PHYSICAL AND CHEMICAL CHARACTERISTICS-Opacity) |
- |
0 |
|
- |
| 10.4(PHYSICAL AND CHEMICAL CHARACTERISTICS- Reversion Test) |
- |
0 |
|
- |
| 10.5(PHYSICAL AND CHEMICAL CHARACTERISTICS- Vicat Softening Temperature) |
- |
0 |
|
- |
| 10.6(PHYSICAL AND CHEMICAL CHARACTERISTICS- Density) |
- |
0 |
|
- |
| 11.1-Table 6(MECHANICAL PROPERTIES-Hydrostatic Pressure Test (Type Test)) |
- |
0 |
|
- |
| 11.1-Table 6(MECHANICAL PROPERTIES-Hydrostatic Pressure Test (Acceptance Test)) |
- |
0 |
|
- |
| 11.1-Table 7(MECHANICAL PROPERTIES-Hydrostatic Pressure Test (Type Test)-for Integral Sealing Ring Sockets) |
- |
0 |
|
- |
| 11.1-Table 7(MECHANICAL PROPERTIES-Hydrostatic Pressure Test (Acceptance Test)-for Integral Sealing Ring Sockets) |
- |
0 |
|
- |
| 11.1.1(MECHANICAL PROPERTIES-Hydrostatic Pressure Test (Acceptance Test)-for Plumbing pipes) |
- |
0 |
|
- |
| 11.2(Resistance to External Blows at 0°C) |
- |
0 |
|
- |
| 10.3(Effect on Water Test) |
- |
0 |
|
- |
| 6.1.2(PVC Resin) |
- |
0 |
|
- |
| 9.1(PIPE ENDS) |
- |
0 |
|
- |
| 10.1(Colour) |
- |
0 |
|
- |
| 10.1(Surface Finish) |
- |
0 |
|
- |
| 7.2.1.1 Table3(Angle of taper (Note-1)) |
- |
0 |
|
- |
| 10.7(Sulphated Ash Content) |
- |
0 |
|
- |
| 5(CLASSIFICATION OF PIPES) |
- |
0 |
|
- |
| Cl-7.1(Mean out side Diameter (For less than or equal to 40 mm- Average of 8 , For higher diameters up to 110 mm average of 6)) |
- |
0 |
|
- |
| 7.1.1.1(DIMENSIONS-PIPE-Mean O.D. (Minimum)) |
- |
0 |
|
- |
| 7.1.1.1(DIMENSIONS-PIPE-Mean O.D. Variation) |
- |
0 |
|
- |
| 7.1.1.2(DIMENSIONS-PIPE-O.D. at any Point (Minimum)) |
- |
0 |
|
- |
| 7.1.1.2(DIMENSIONS-PIPE-Ovality (Maximum)) |
- |
0 |
|
- |
| 7.1.2.1(DIMENSIONS-PIPE-Thickness(Minimum)) |
- |
0 |
|
- |
| 7.1.2.1(DIMENSIONS-PIPE-Thickness(Maximum)) |
- |
0 |
|
- |
| 7.1.2.1(DIMENSIONS-PIPE-Average Thickness) |
- |
0 |
|
- |
| Cl- 7.2(Socket length (Take 4 reading & minimum will be reported)) |
- |
0 |
|
- |
| 7.2.1.1-Table 3(DIMENSIONS-Socket-Sockets for solvent cement jointing-Minimum Length) |
- |
0 |
|
- |
| 7.2.1.1-Table 3(DIMENSIONS-Socket-Sockets for solvent cement jointing-Diameter at mid point of the socket length (Minimum)) |
- |
0 |
|
- |
| 7.2.1.1-Table 3(DIMENSIONS-Socket-Sockets for solvent cement jointing-Diameter at mid point of the socket length (Maximum)) |
- |
0 |
|
- |
| 7.2.1.2(a)-Table 5(DIMENSIONS-Sockets for elastomeric sealing ring joints-Minimum depth of engagement) |
- |
0 |
|
- |
| 7.2.1.2-Table 4(DIMENSIONS-Sockets for elastomeric sealing ring joints-Socket inner Diameter) |
- |
0 |
|
- |
| 8(SEALING RINGS) |
- |
0 |
|
- |
| 10.1(PHYSICAL AND CHEMICAL CHARACTERISTICS-Visual Appearance) |
- |
0 |
|
- |
| 10.2(PHYSICAL AND CHEMICAL CHARACTERISTICS-Opacity) |
- |
0 |
|
- |
| 10.4(PHYSICAL AND CHEMICAL CHARACTERISTICS- Reversion Test) |
- |
0 |
|
- |
| 10.5(PHYSICAL AND CHEMICAL CHARACTERISTICS- Vicat Softening Temperature) |
- |
0 |
|
- |
| 10.6(PHYSICAL AND CHEMICAL CHARACTERISTICS- Density) |
- |
0 |
|
- |
| 11.1-Table 6(MECHANICAL PROPERTIES-Hydrostatic Pressure Test (Type Test)) |
- |
0 |
|
- |
| 11.1-Table 6(MECHANICAL PROPERTIES-Hydrostatic Pressure Test (Acceptance Test)) |
- |
0 |
|
- |
| 11.1-Table 7(MECHANICAL PROPERTIES-Hydrostatic Pressure Test (Type Test)-for Integral Sealing Ring Sockets) |
- |
0 |
|
- |
| 11.1-Table 7(MECHANICAL PROPERTIES-Hydrostatic Pressure Test (Acceptance Test)-for Integral Sealing Ring Sockets) |
- |
0 |
|
- |
| 11.1.1(MECHANICAL PROPERTIES-Hydrostatic Pressure Test (Acceptance Test)-for Plumbing pipes) |
- |
0 |
|
- |
| 11.2(Resistance to External Blows at 0°C) |
- |
0 |
|
- |
| 10.3(Effect on Water Test) |
- |
0 |
|
- |
| 6.1.2(PVC Resin) |
- |
0 |
|
- |
| 9.1(PIPE ENDS) |
- |
0 |
|
- |
| 10.1(Colour) |
- |
0 |
|
- |
| 10.1(Surface Finish) |
- |
0 |
|
- |
| 7.2.1.1 Table3(Angle of taper (Note-1)) |
- |
0 |
|
- |
| 10.7(Sulphated Ash Content) |
- |
0 |
|
- |
| 5(CLASSIFICATION OF PIPES) |
- |
0 |
|
- |
| Cl-7.1(Mean out side Diameter (For less than or equal to 40 mm- Average of 8 , For higher diameters up to 110 mm average of 6)) |
- |
0 |
|
- |
| 7.1.1.1(DIMENSIONS-PIPE-Mean O.D. (Minimum)) |
- |
0 |
|
- |
| 7.1.1.1(DIMENSIONS-PIPE-Mean O.D. Variation) |
- |
0 |
|
- |
| 7.1.1.2(DIMENSIONS-PIPE-O.D. at any Point (Minimum)) |
- |
0 |
|
- |
| 7.1.1.2(DIMENSIONS-PIPE-Ovality (Maximum)) |
- |
0 |
|
- |
| 7.1.2.1(DIMENSIONS-PIPE-Thickness(Minimum)) |
- |
0 |
|
- |
| 7.1.2.1(DIMENSIONS-PIPE-Thickness(Maximum)) |
- |
0 |
|
- |
| 7.1.2.1(DIMENSIONS-PIPE-Average Thickness) |
- |
0 |
|
- |
| Cl- 7.2(Socket length (Take 4 reading & minimum will be reported)) |
- |
0 |
|
- |
| 7.2.1.1-Table 3(DIMENSIONS-Socket-Sockets for solvent cement jointing-Minimum Length) |
- |
0 |
|
- |
| 7.2.1.1-Table 3(DIMENSIONS-Socket-Sockets for solvent cement jointing-Diameter at mid point of the socket length (Minimum)) |
- |
0 |
|
- |
| 7.2.1.1-Table 3(DIMENSIONS-Socket-Sockets for solvent cement jointing-Diameter at mid point of the socket length (Maximum)) |
- |
0 |
|
- |
| 7.2.1.2(a)-Table 5(DIMENSIONS-Sockets for elastomeric sealing ring joints-Minimum depth of engagement) |
- |
0 |
|
- |
| 7.2.1.2-Table 4(DIMENSIONS-Sockets for elastomeric sealing ring joints-Socket inner Diameter) |
- |
0 |
|
- |
| 8(SEALING RINGS) |
- |
0 |
|
- |
| 10.1(PHYSICAL AND CHEMICAL CHARACTERISTICS-Visual Appearance) |
- |
0 |
|
- |
| 10.2(PHYSICAL AND CHEMICAL CHARACTERISTICS-Opacity) |
- |
0 |
|
- |
| 10.4(PHYSICAL AND CHEMICAL CHARACTERISTICS- Reversion Test) |
- |
0 |
|
- |
| 10.5(PHYSICAL AND CHEMICAL CHARACTERISTICS- Vicat Softening Temperature) |
- |
0 |
|
- |
| 10.6(PHYSICAL AND CHEMICAL CHARACTERISTICS- Density) |
- |
0 |
|
- |
| 11.1-Table 6(MECHANICAL PROPERTIES-Hydrostatic Pressure Test (Type Test)) |
- |
0 |
|
- |
| 11.1-Table 6(MECHANICAL PROPERTIES-Hydrostatic Pressure Test (Acceptance Test)) |
- |
0 |
|
- |
| 11.1-Table 7(MECHANICAL PROPERTIES-Hydrostatic Pressure Test (Type Test)-for Integral Sealing Ring Sockets) |
- |
0 |
|
- |
| 11.1-Table 7(MECHANICAL PROPERTIES-Hydrostatic Pressure Test (Acceptance Test)-for Integral Sealing Ring Sockets) |
- |
0 |
|
- |
| 11.1.1(MECHANICAL PROPERTIES-Hydrostatic Pressure Test (Acceptance Test)-for Plumbing pipes) |
- |
0 |
|
- |
| 11.2(Resistance to External Blows at 0°C) |
- |
0 |
|
- |
| 10.3(Effect on Water Test) |
- |
0 |
|
- |
| 6.1.2(PVC Resin) |
- |
0 |
|
- |
| 9.1(PIPE ENDS) |
- |
0 |
|
- |
|
31 Dec, 2026 |
- Included w.e.f. 28-06-2023. |