| 12871 |
BIS, Southern Regional Laboratory (SRL)
| None
| IS 7129 (2021) |
POTASSIUM CARBONATE ANHYDROUS SPECIFICATION (Second Revision) |
- |
Please see remarks View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4.1 (Description) |
- |
|
|
|
| 4.3 - Table 1 - Sl No - i (Total Alkalinity (as K2CO3) - Annex A 2) |
- |
|
|
|
| 4.3 - Table 1 - Sl No - ii (Potassium bicarbonate (as KHCO3) - Annex A 3) |
- |
|
|
|
| 4.3 - Table 1 - Sl No - ii (Free alkali (as KOH)- Annex A 3) |
- |
|
|
|
| 4.3 - Table 1 - Sl No - iii (Sulphates (as K2SO4) - Annex A 4) |
- |
|
|
|
| 4.3 - Table 1 - Sl No - iv (Chlorides (as KCl) - Annex A 5) |
- |
|
|
|
| 4.3 - Table 1 - Sl No - v (Matter insoluble in water - Annex A 6) |
- |
|
|
|
| 4.3 - Table 1 - Sl No - vi (Iron (as Fe) - Annex A 7 & A 12) |
- |
|
|
|
| 4.3 - Table 1 - Sl No - vii (Heavy metals (as Pb - Annex A 8 & A 12) |
- |
|
|
|
| 4.3 - Table 1 - Sl No - viii (Loss on heating at 150oC - Annex A 9) |
- |
|
|
|
| 4.3 - Table 1 - Sl No - ix (Sodium (as Na) - Annex A 10 & A 12) |
- |
|
|
|
|
- |
- " 250 g
Excluding Except Calcium and Magnesium and heavy metals |
| 12872 |
BIS, Central Laboratory (CL)
| None
| IS 13779 (2020) |
ac STATIC WATTHOUR METERS CLASS 1 AND 2-Specefication |
- |
Please see remarks View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4 (Classification) |
- |
|
|
|
| 5.1 (Standard Reference Voltages) |
- |
|
|
|
| 5.2 (Standard Basic Currents) |
- |
|
|
|
| 5.3 (Rated Maximum Current) |
- |
|
|
|
| 5.4 (Standard Frequency) |
- |
|
|
|
| 6.1 (General) |
- |
|
|
|
| 6.2 (Meter Case) |
- |
|
|
|
| 12.16 & 11.7 (Test of repeatability of error) |
- |
|
|
|
| 6.3 (Window) |
- |
|
|
|
| 6.4 (Terminals, terminal block and protective earth terminal) |
- |
|
|
|
| 6.5 (Terminals covers and Extended Terminal Cover) |
- |
|
|
|
| 6.6 (Clearance and creepage distances) |
- |
|
|
|
| 12.15 & 11.6 (Test of meter constant) |
- |
|
|
|
| 6.7 (Insulating encased meter) |
- |
|
|
|
| 6.10 (Display of measured values) |
- |
|
|
|
| 6.11 (Output device) |
- |
|
|
|
| 7.1 (Name Plate) |
- |
|
|
|
| 7.2 (Connection diagrams and terminal marking) |
- |
|
|
|
| 12.14 & 11.5 (Test of starting condition) |
- |
|
|
|
| 12.13 & 11.4 (Test of no-load condition) |
- |
|
|
|
| 12.3.3 (Spring hammer test) |
- |
|
|
|
| 12.4 (Test of resistance to heat and fire) |
- |
|
|
|
| 11.2 (Test on limits of error due to other influence quantities) |
- |
|
|
|
| 11.1 (Test on limits of error due to variation of current) |
- |
|
|
|
| 12.7.2 (Test of influence of supply voltage) |
- |
|
|
|
| 12.7.2 (Voltage interruptions of Vref=100% Interruption time: 1sec Number of interruptions: 3 Restoring time between interruptions: 50msec.) |
- |
|
|
|
| 12.7.2 (Voltage interruptions of Vref=100% Interruption time: 20msec Number of interruptions: 1) |
- |
|
|
|
| 12.7.2 (Voltage dip of Vref=50% Dip time: 1 min Number of dips: 1) |
- |
|
|
|
| 12.7.6.4 (Insulation resistance test) |
- |
|
|
|
| 12.7.4 (Test of Influence of self heating) |
- |
|
|
|
| 12.7.5 (Test of influence of heating) |
- |
|
|
|
| 12.7.6.3 (ac high voltage test) |
- |
|
|
|
| Cl.11.2 and Table 17 of IS 13779:2020 (Limits of error due to other influence quantities) |
- |
|
|
|
| Cl.11.2 and Table 17 of IS 13779:2020 (Limits of error due to other influence quantities) |
- |
|
|
|
| Cl.11.2 and Table 17 of IS 13779:2020 (Limits of error due to other influence quantities) |
- |
|
|
|
| Cl.11.2 and Table 17 of IS 13779:2020 (Limits of error due to other influence quantities) |
- |
|
|
|
| Cl.11.2 and Table 17 of IS 13779:2020 (Limits of error due to other influence quantities) |
- |
|
|
|
| AC static watihour meters, class 1 and 2 - Specification (First Revision) (Limits of error due to other influence quantities) |
- |
|
|
|
| Cl.11.2 and Table 17 of IS 13779:2020 (Limits of error due to other influence quantities) |
- |
|
|
|
| Cl.11.2 and Table 17 of IS 13779:2020 (Limits of error due to other influence quantities) |
- |
|
|
|
| Cl.11.2 and Table 17 of IS 13779:2020 (Limits of error due to other influence quantities) |
- |
|
|
|
| Cl.11.2 and Table 17 of IS 13779:2020 (Limits of error due to other influence quantities) |
- |
|
|
|
| Cl.11.2 and Table 17 of IS 13779:2020 (Limits of error due to other influence quantities) |
- |
|
|
|
| Cl.11.2 and Table 17 of IS 13779:2020 (Limits of error due to other influence quantities) |
- |
|
|
|
| Cl.11.2 and Table 17 of IS 13779:2020 (Limits of error due to other influence quantities) |
- |
|
|
|
| Cl.11.2 and Table 17 of IS 13779:2020 (Limits of error due to other influence quantities) |
- |
|
|
|
| Cl.11.2 and Table 17 of IS 13779:2020 (Limits of error due to other influence quantities) |
- |
|
|
|
| Cl.11.2 and Table 17 of IS 13779:2020 (Limits of error due to other influence quantities) |
- |
|
|
|
| Cl.11.2 and Table 17 of IS 13779:2020 (Limits of error due to other influence quantities) |
- |
|
|
|
| Cl.11.2 and Table 17 of IS 13779:2020 (Limits of error due to other influence quantities) |
- |
|
|
|
| Cl.11.2 and Table 17 of IS 13779:2020 (Limits of error due to other influence quantities) |
- |
|
|
|
| Cl.11.2 and Table 17 of IS 13779:2020 (Limits of error due to other influence quantities) |
- |
|
|
|
| Cl.11.2 and Table 17 of IS 13779:2020 (Limits of error due to other influence quantities) |
- |
|
|
|
| Cl.11.2 and Table 17 of IS 13779:2020 (Limits of error due to other influence quantities) |
- |
|
|
|
| Cl.11.2 and Table 17 of IS 13779:2020 (Limits of error due to other influence quantities) |
- |
|
|
|
| Cl.11.2 and Table 17 of IS 13779:2020 (Limits of Error and Interpretation or Test Results) |
- |
|
|
|
| Cl.11.2 and Table 17 of IS 13779:2020 (Limits of Error and Interpretation or Test Results) |
- |
|
|
|
| Cl.11.2 and Table 17 of IS 13779:2020 (Limits of Error and Interpretation or Test Results) |
- |
|
|
|
| Cl.11.2 and Table 17 of IS 13779:2020 (Limits of Error and Interpretation or Test Results) |
- |
|
|
|
| Cl.11.2 and Table 17 of IS 13779:2020 (Limits of Error and Interpretation or Test Results) |
- |
|
|
|
| Cl.11.2 and Table 17 of IS 13779:2020 (Limits of Error and Interpretation or Test Results) |
- |
|
|
|
| Cl.11.2 and Table 17 of IS 13779:2020 (Limits of Error and Interpretation or Test Results) |
- |
|
|
|
| Cl.11.2 and Table 17 of IS 13779:2020 (Limits of Error and Interpretation or Test Results) |
- |
|
|
|
| Cl.11.2 and Table 17 of IS 13779:2020 (Limits of Error and Interpretation or Test Results) |
- |
|
|
|
| Cl.11.2 and Table 17 of IS 13779:2020 (Limits of Error and Interpretation or Test Results) |
- |
|
|
|
| Cl.11.2 and Table 17 of IS 13779:2020 (Limits of Error and Interpretation or Test Results) |
- |
|
|
|
| Cl.11.2 and Table 17 of IS 13779:2020 (Limits of Error and Interpretation or Test Results) |
- |
|
|
|
|
- |
- The following test facilities for clauses are not available: (a) Test of power consumption test (Cl.12.7.1) (b) Radio interference measurement Cl.12.9.5 (c) Fast transient bursttest Cl. 12.9.4 (d)Test of immunity to electrostatic discharges Cl.12.9.2 (e) Test of immunity to electromagnetic HF field Cl. 12.9.3 . (f) Dry heat test Cl.12.6.1 (g)Cold test Cl.12.6.2 (h) Damp heat cycliclest Cl.12.6.3 (i) Vibration test Cl.12.3.2 (j) Shock lest Cl.12.3.1 |
| 12873 |
GLOBAL LAB AND CONSULTANCY SERVICES LLP, SALEM
| 6170916
| IS 12923 (1990) |
Cane gur (Jaggery) - Specification |
Grade 1 & Grade 2 |
3500 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Table 1 (i), IS 15279 CL 12(Sucrose (on dry basis), Grade 1) |
- |
600 |
|
- |
| Table 1 (i), IS 15279 CL 12(Sucrose (on dry basis), Grade 2) |
- |
600 |
|
- |
| Table 1 (ii), IS 15279 CL 7(Reducing sugars (on dry basis), Grade 1) |
- |
600 |
|
- |
| Table 1 (ii), IS 15279 CL 7(Reducing sugars (on dry basis), Grade 2) |
- |
600 |
|
- |
| Table 1 (iii), IS 15279 CL 4(Moisture, Grade 1) |
- |
300 |
|
- |
| Table 1 (iii), IS 15279 CL 4(Moisture, Grade 2) |
- |
300 |
|
- |
| Table 1 (iv), IS 15279 CL 14(Water insoluble matter (on dry basis), Grade 1) |
- |
500 |
|
- |
| Table 1 (iv), IS 15279 CL 14(Water insoluble matter (on dry basis), Grade 2) |
- |
500 |
|
- |
| Table 1 (v), IS 15279 CL 10(Sulphated ash (on dry basis), Grade 1) |
- |
500 |
|
- |
| Table 1 (v), IS 15279 CL 10(Sulphated ash (on dry basis), Grade 1) |
- |
500 |
|
- |
| Table 1 (vi), IS 15279 CL 13(Sulphur dioxide (on dry basis), Grade 1) |
- |
500 |
|
- |
| Table 1 (vi), IS 15279 CL 13(Sulphur dioxide (on dry basis), Grade 2) |
- |
500 |
|
- |
| Table 1 (vii), Annex A(Ash insoluble in dilute hydrochloric acid (on dry basis), Grade 1) |
- |
500 |
|
- |
| Table 1 (vii), Annex A(Ash insoluble in dilute hydrochloric acid (on dry basis), Grade 2) |
- |
500 |
|
- |
|
13 Jul, 2028 |
- - |
| 12874 |
BIS, Southern Regional Laboratory (SRL)
| None
| IS 2556 : Part 5 (1994) |
Vitreous sanitary appliances (Vitreous China) - Specification: Part 5 specific requirements of laboratory sinks |
- |
Rs 675/- +charges as per part I View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 3 (General requirements-Thickness
IS 2556 (Part 1)) |
- |
|
|
|
| 3 (General requirements-PERFORMANCE REQUIllEMENTS-WARPAGE IS 2556 (Part 1)) |
- |
|
|
|
|
- |
- 2 NOS |
| 12875 |
BIS, Central Laboratory (CL)
| None
| IS 553 (1984) |
Specification for rosin (Gum Rosin) (Second Revision) |
- |
Rs.3304.00 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4.1 (Description) |
- |
|
|
|
| 4.2 (Solubility) |
- |
|
|
|
| 4.3, Table 1 (i) (Colour) |
- |
|
|
|
| 4.3, Table 1 (ii) (Softening point, °C, Min) |
- |
|
|
|
| 4.3, Table 1 (iii) (Relative density, 27°/27°C) |
- |
|
|
|
| 4.3, Table 1 (iv) (Acid number, Min) |
- |
|
|
|
| 4.3, Table 1 (v) (Saponification number, Min) |
- |
|
|
|
| 4.3, Table 1 (vi) (Volatile matter, percent by mass,) |
- |
|
|
|
| 4.3, Table 1 (vii) (Ash content, percent by mass, Max) |
- |
|
|
|
| 4.3, Table 1 (viii) (Matter insoluble in toluene, percent by mass, Max) |
- |
|
|
|
| 43, Table 1 (ix) (Unsaponifiable matter, percent by mass, Max) |
- |
|
|
|
|
- |
- Excluding Clause 4.4, Table 2, (i)Copper content, (ii) Manganese content |
| 12876 |
BIS, Central Laboratory (CL)
| None
| IS 3119 (1978) |
Specification for hot air sterilizers (First Revision) |
- |
- View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 3.1 (3.1 Voltage Rating) |
- |
|
|
|
| 3.2 (3.2 Rated Input) |
- |
|
|
|
| 4.1 (4.1 Materials) |
- |
|
|
|
| 5 (Construction) |
- |
|
|
|
| 5.2.1 (Cabinet) |
- |
|
|
|
| 5.2.2 (Cabinet) |
- |
|
|
|
| 5.2.3 (Cabinet) |
- |
|
|
|
| 5.3 (Heating element) |
- |
|
|
|
| 5.4 (5.4 Wiring and Components) |
- |
|
|
|
| 5.5.1 (Thermostat) |
- |
|
|
|
| 5.5.2 (Thermostat) |
- |
|
|
|
| 5.5.3 (Thermostat) |
- |
|
|
|
| 5.5.4 (Thermostat) |
- |
|
|
|
| 5.5.5 (Thermostat) |
- |
|
|
|
| 5.5.6 (Thermostat) |
- |
|
|
|
| 5.5.7 (Thermostat) |
- |
|
|
|
| 5.6 (Thermometer) |
- |
|
|
|
| 6 (General and Safety Requirements) |
- |
|
|
|
| 6.1 (Protection Against Electric Shock) |
- |
|
|
|
| 6.2 (Temperature limit) |
- |
|
|
|
| 6.3 (Electric Insulation) |
- |
|
|
|
| 6.4 (Stability) |
- |
|
|
|
| 6.5 (Mechanical Strength) |
- |
|
|
|
| 6.6 (Supply connections) |
- |
|
|
|
| 6.7 (6.7 Terminals) |
- |
|
|
|
| 6.9 (6.9 Screws and Connections) |
- |
|
|
|
| 6.8 (6.8 Earthing) |
- |
|
|
|
| 6.10 (6.10 Resistance to Rusting) |
- |
|
|
|
| 7.1 (7.1 Heating-Up Time,Minutes) |
- |
|
|
|
| 7.2 (7.2 Temperature Variation) |
- |
|
|
|
| 8.1 (8.1 Each incubator shall be marked indelibly and clearly in accordancewith 25 of IS : 302-1973* on its outer surface or on a name plate firmly) |
- |
|
|
|
| 8.1.1 (8.1.1 The marking shall also show the minimum ambient temperature at which the incubator is suitable for operation.) |
- |
|
|
|
| 8.1.2 (Marking) |
- |
|
|
|
| 8.2 (8.2 Marking of Earth Terminal) |
- |
|
|
|
| 8.3 (8.3 Instructions for Use) |
- |
|
|
|
| 9.2.1 (9.2.1 Visual Examination and Inspection) |
- |
|
|
|
| 9.2.2 (9.2.2 Insulation Resistance Test) |
- |
|
|
|
| 9.2.4 (9.2.4) |
- |
|
|
|
| 9.2.5 (9.2.5 Temperature Variation Test) |
- |
|
|
|
| 9.2.6 (9.2.6 Temperature Drift Test,C) |
- |
|
|
|
| 9.2.7 (9.2.7 Test for Reproducibility of Temperature Setting,C) |
- |
|
|
|
| 9.2.8 (9.2.8 Test for Time of Temperature Recovery) |
- |
|
|
|
| 9.2.9 (9.2.9 Test for Reproducibility of Temperature Setting-) |
- |
|
|
|
| 9.2.10 (9.2.10 Temperature Overshoot Test) |
- |
|
|
|
|
- |
- - |
| 12877 |
BIS, Eastern Regional Laboratory (ERL)
| None
| IS 2141 (2000) |
Hot dip galvanized stay strand - Specification (Fourth Revision) |
For all grade |
Rs7935/- View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 9.2 referes to IS 4826, Table 1 (Mass of Zinc coating- as per IS 6745 for 0.2 to 0.32 mm dia For Hard Core) |
- |
|
|
|
| 9.2 referes to IS 4826, Table 1 (Uniformity of zinc coating- As per IS 2633 for Dia 3.15 to 3.55 mm For Hard Core) |
- |
|
|
|
| 9.2 referes to IS 4826, Table 1 (Mass of Zinc coating- as per IS 6745 for 0.56 to 0.63 mm dia For Soft Core) |
- |
|
|
|
| 9.2 referes to IS 4826, Table 1 (Uniformity of zinc coating- As per IS 2633 for Dia 0.20 to 0.32 mm For Soft Core) |
- |
|
|
|
| 6 (a) Lay) |
- |
|
|
|
| 7 (Freedom from defects) |
- |
|
|
|
| 4 (S) |
- |
|
|
|
| 4 (P) |
- |
|
|
|
| CL 8.2 (AVG single wire dia (08)) |
- |
|
|
|
|
- |
- Separate single wire before stranding to be provide for breaking force of wires and dimension |
| 12878 |
CIPET, Hyderabad
| 6111634
| IS 16647 (2017) |
Oriented unplasticized polyvinyl chloride (Pvc - O) pipes for water supply - Specification |
Oriented unplasticized polyvinyl chloride (Pvc - O) pip |
53875 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 5.5(Â Density, g/cc) |
- |
500 |
|
- |
| 6.0(CLASSIFICATION OF PIPES, table-2) |
- |
0 |
|
- |
| 7, see 8.3 and fig-1( GENERAL REQUIREMENTS OF PIPES/ visual appearance) |
- |
300 |
|
- |
| 7.2(Â Colour) |
- |
300 |
|
- |
| 7.3(Â Opacity) |
- |
575 |
|
- |
| 8.1.1, 8.1.1.2, table-3(Dimension of Pipes / Diameter/8.1.1.2 Diameter at any point) |
- |
500 |
|
- |
| 8.1.2, table 4 to 7(Wall Thickness) |
- |
500 |
|
- |
| 8.1.3 (Length, meter) |
- |
500 |
|
- |
| 8.2 table-9(Dimensions of Integral Socket) |
- |
500 |
|
- |
| 8.2 table-9( Pipe Ends) |
- |
500 |
|
- |
| 9.3 table-12(Â Ring Stiffness) |
- |
1100 |
|
- |
| 9 /9.1 / 27 degree centigrate(MECHANICAL CHARACTERISTICS OF PIPES9./ Resistance to Hydrostatic Pressure) |
- |
13400 |
|
- |
| 9.2, table -11( Resistance to External Blows at 0 °C) |
- |
1000 |
|
- |
| 9.4, annexure-E( Orientation Factor) |
- |
1400 |
|
- |
| 10, table-13(Â Â PHYSICAL AND 1CHARACTERISTICS) |
- |
3000 |
|
- |
| 11,11.1(Â Â Â Â Â Â MECHANICAL CHARACTERISTICS OF ASSEMBLIES INCLUDING JOINTS/ 11.1 Assemblies with Non-End-Load-Bearing Joints) |
- |
1000 |
|
- |
| 11.2 / 11.2.1(Â Â Â Â Â Â Â Â Short-Term Pressure Test for Leak Tightness of Assemblies) |
- |
1000 |
|
- |
| 11.3(Â Â Â Â Â Short-Term Negative Pressure Test for Leak Tightness of Assemblies) |
- |
11000 |
|
- |
|
23 Feb, 2027 |
- - |
| 12879 |
BIS, Western Regional Laboratory (WRL)
| None
| IS 3099 : Part 1 AND 2 (1992) |
Microscopes - Slips and slidesspecification: Part 1 microscope slips: Part 2 microscope slides (First Revision) |
- |
Rs1800.00/, Rs.1200.00/ View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| (Cl.5.1 (Surface Finish
) |
- |
|
|
|
| Cl 3 (Dimensions Thickness) |
- |
|
|
|
| Cl 3 (Dimensions width) |
- |
|
|
|
| Cl 3 (Dimensions length ) |
- |
|
|
|
| Cl 3 (Dimensions Side -22 ) |
- |
|
|
|
| (Cl.7) (Edge Quality ) |
- |
|
|
|
| (CL.4) (Visible Seed ) |
- |
|
|
|
| Cl 3 (General purpose
High performance
) |
- |
|
|
|
|
- |
- Test facilities are not available for the following:
(a) Optical properties |
| 12880 |
CIPET, Hyderabad
| 6111634
| IS 14399 : Part 1 and 2 (1996) |
Hot Press Moulded Thermosetting Glass Fibre Reinforced Polyester Resin (GRP) Sectional Water Storage Tanks : Part 1 palels, Part 2 Guidelines for assembly, installation and test |
Hot Press Moulded Thermosetting Glass Fibre Reinforced |
12375 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 6.1(Flange of Panels) |
- |
250 |
|
- |
| 6.4(Type/Thickness of panel) |
- |
250 |
|
- |
| 7.0(Visual inspection of the panels) |
- |
300 |
|
- |
| 8, Table-1, Annex-B(Tensile Strength) |
- |
1100 |
|
- |
| 8, Table-1, Annex-C(Bending strength) |
- |
1100 |
|
- |
| 8, Table-1, Annex-D(Elastic moduius in Bend) |
- |
1100 |
|
- |
| 8, Table-1, Annex-E(Glass Content) |
- |
950 |
|
- |
| 8, Table-1, Annex-F(Barcoal Hardness) |
- |
375 |
|
- |
| 8, Table-1, Annex-G(Water Absorption) |
- |
600 |
|
- |
|
23 Feb, 2027 |
- - |
| 12881 |
BIS, Northern Regional Laboratory (NRL)
| None
| IS 1061 (2017) |
Disinfectant fluids, phenolic type - Specification (Fifth Revision) |
- |
Class Black fluid-Rs.9204. Class White fluid - Rs.10504 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4.1.1 (Composition and Description) |
- |
|
|
|
| 4.6 (Detection of Phenolic Compounds) |
- |
|
|
|
| 4.2 (Stability after Dilution) |
- |
|
|
|
| 4.4 (Mercury Compounds) |
- |
|
|
|
| 4.5 (Stability on Storage) |
- |
|
|
|
| 4.3/3.2 (Germicidal Value) |
- |
|
|
|
| 4.3/3.3 (Germicidal Value) |
- |
|
|
|
| 3.1 (Chem) (Class) |
- |
|
|
|
| 3.2 (Chem) (Grade) |
- |
|
|
|
| 3.3 (Chem) (Type) |
- |
|
|
|
| 4.1.1 (chem) (Composition and Description) |
- |
|
|
|
| 4.1.2 (Chem) (Composition and Description) |
- |
|
|
|
| 4.2 (Chem) (Stability after Dilution) |
- |
|
|
|
| 4.3/3.2 (Chem) (Germicidal Value) |
- |
|
|
|
| 4.3/3.3 (Chem) (Germicidal Value) |
- |
|
|
|
| 4.3/3.4 (Chem) (Germicidal Value) |
- |
|
|
|
| 4.3/3.5 (Chem) (Germicidal Value) |
- |
|
|
|
| 4.3/3.5 (Chem) (Germicidal Value) |
- |
|
|
|
| 4.3/3.5 (Chem) (Germicidal Value) |
- |
|
|
|
| 4.4 (Chem) (Mercury Compounds) |
- |
|
|
|
| 4.5 (Chem) (Stability on Storage) |
- |
|
|
|
| 4.6 (Chem) (Detection of Phenolic Compounds) |
- |
|
|
|
|
- |
- Test facility is complete |
| 12882 |
BIS, Central Laboratory (CL)
| None
| IS 14768 : Part 2 (2003) |
Conduit fittings for electrical installations - Specification: Part 2 metal conduit fittings |
- |
Rs.7800.00 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4 (General requirements, Cl. 4 of IS 14768-1) |
- |
|
|
|
| 6 (Classification, Cl. 6.1 of IS 14768-1) |
- |
|
|
|
| 6 (Classification, Cl. 6.2 of IS 14768-1) |
- |
|
|
|
| 6 (Classification, Cl. 6.3 of IS 14768-2) |
- |
|
|
|
| 6 (Classification, Cl. 6.4 of IS 14768-2) |
- |
|
|
|
| 6 (Classification, Cl. 6.7 of IS 14768-3) |
- |
|
|
|
| 6 (Classification, Cl. 6.8 of IS 14768-4) |
- |
|
|
|
| 6 (Classification, Cl. 6.9 of IS 14768-5) |
- |
|
|
|
| 6 (Classification, Cl. 6.10 of IS 14768-6) |
- |
|
|
|
| 6 (Classification, Cl. 6.11 of IS 14768-7) |
- |
|
|
|
| 7 (Marking, Cl. 7.1 of IS 14768-1) |
- |
|
|
|
| 7 (Marking, Cl. 7.1 of IS 14768-1) |
- |
|
|
|
| 7 (Marking, Cl. 7.1 of IS 14768-1) |
- |
|
|
|
| 7 (Marking, Cl. 7.1 of IS 14768-1) |
- |
|
|
|
| 7 (Marking, Cl. 7.1 of IS 14768-1) |
- |
|
|
|
| 7 (Marking, Cl. 7.1 of IS 14768-1) |
- |
|
|
|
| 7 (Marking, Cl. 7.1 of IS 14768-1) |
- |
|
|
|
| 7.101 (Marking, IS 14768-2) |
- |
|
|
|
| 8 (Dimensions, Cl. 8.1 of IS 14768-1) |
- |
|
|
|
| 8 (Dimensions, Cl. 8.2 of IS 14768-1) |
- |
|
|
|
| 9 (Construction, Cl. 9.1 of IS 14768-1) |
- |
|
|
|
| 9 (Construction, Cl. 9.2 of IS 14768-1) |
- |
|
|
|
| 9 (Construction, Cl. 9.3 of IS 14768-1) |
- |
|
|
|
| 9 (Construction, Cl. 9.4 of IS 14768-1) |
- |
|
|
|
| 9 (Construction, Cl. 9.5 of IS 14768-1) |
- |
|
|
|
| 9 (Construction, Cl. 9.6 of IS 14768-1) |
- |
|
|
|
| 9 (Construction, Cl. 9.7 of IS 14768-1) |
- |
|
|
|
| 10 (Mechanical Properties, Cl. 10.3 of IS 14768-1) |
- |
|
|
|
| 10 (Mechanical Properties, Cl. 10.4 of IS 14768-1) |
- |
|
|
|
|
- |
- Excluding Impact test(Cl.10.3), Suspended load test(Cl.10.4), Electrical Impendence test(Cl.13.7),External influences(Cl.14), Test on joints(Cl.15), |
| 12883 |
BIS, Northern Regional Laboratory (NRL)
| None
| IS 5487 (1992) |
Metal polish, liquid - Specification (First Revision) |
- |
Rs.4800.00 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
No Record Found
|
|
- |
- Test Facility not available |
| 12884 |
BIS, Northern Regional Laboratory (NRL)
| None
| IS 4072 (1975) |
Specification for steel for spring washers (First Revision) |
- |
- View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl. 2.1, 5.1, 5.2 Table 1 (Carbon) |
- |
|
|
|
| Cl. 2.1, 5.1, 5.2 Table 1 (Silicon) |
- |
|
|
|
| Cl. 2.1, 5.1, 5.2 Table 1 (Manganese) |
- |
|
|
|
| Cl. 2.1, 5.1, 5.2 Table 1 (Sulphur) |
- |
|
|
|
| Cl. 2.1, 5.1, 5.2 Table 1 (Phosphorous) |
- |
|
|
|
| Cl. 2.1, 5.1, 5.2 Table 1 (Chromium) |
- |
|
|
|
| Cl. 2.1, 5.1, 5.2 Table 1 (Vanadium) |
- |
|
|
|
|
- |
- Excluding Feedom from defects, Microalloying Elements |
| 12885 |
BIS, Northern Regional Laboratory (NRL)
| None
| IS 3885 : Part 1 (1992) |
Steel for the manufacture of laminated springs (Railway Rolling Stock): Part 1 flat sections - Specification (Second Revision) |
- |
Rs. 975/- View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl. 6.1 Table 1 (Carbon) |
- |
|
|
|
| Cl. 6.1 Table 1 (Silicon) |
- |
|
|
|
| Cl. 6.1 Table 1 (Manganese) |
- |
|
|
|
| Cl. 6.1 Table 1 (Sulphur) |
- |
|
|
|
| Cl. 6.1 Table 1 (Phosphorous) |
- |
|
|
|
|
- |
- Excluding Decarburization |
| 12886 |
BIS, Northern Regional Laboratory (NRL)
| None
| IS 3748 (1990) |
Tool and die steels - Specification (Second Revision) |
- |
- View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl. 7.1, 7.2, 12.1 Table 1 (Carbon) |
- |
|
|
|
| Cl. 7.1, 7.2, 12.1 Table 1 (Silicon) |
- |
|
|
|
| Cl. 7.1, 7.2, 12.1 Table 1 (Manganese) |
- |
|
|
|
| Cl. 7.1, 7.2, 12.1 Table 1 (Nickel) |
- |
|
|
|
| Cl. 7.1, 7.2, 12.1 Table 1 (Chromium) |
- |
|
|
|
| Cl. 7.1, 7.2, 12.1 Table 1 (Molybdenum) |
- |
|
|
|
| Cl. 7.1, 7.2, 12.1 Table 1 (Vanadium) |
- |
|
|
|
| Cl. 7.1, 7.2, 12.1 Table 1 (Tungsten) |
- |
|
|
|
| Cl. 7.1, 7.2, 12.1 Table 1 (Sulphur) |
- |
|
|
|
| Cl. 7.1, 7.2, 12.1 Table 1 (Phosphorous) |
- |
|
|
|
| Cl. 7.2, (Copper) |
- |
|
|
|
| Cl. 7.2, (Cobalt) |
- |
|
|
|
| Cl. 7.2, (Tin) |
- |
|
|
|
|
- |
- Excluding No, Cr, No, V, An and W |
| 12887 |
BIS, Northern Regional Laboratory (NRL)
| None
| IS 3298 (1981) |
Specification for mild steel rivet bars for ship building (First Revision) |
- |
- View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl. 5.1, 5.2, 5.3, 5.4 (carbon) |
- |
|
|
|
| Cl. 5.1, 5.2, 5.3, 5.4 (Sulphur) |
- |
|
|
|
| Cl. 5.1, 5.2, 5.3, 5.4 (Phosphorous) |
- |
|
|
|
| Cl. 5.1, 5.2, 5.3, 5.4 (Copper) |
- |
|
|
|
| Cl. 5.1, 5.2, 5.3, 5.4 (Silicon) |
- |
|
|
|
|
- |
- Excluding Cu, Al |
| 12888 |
BIS, Northern Regional Laboratory (NRL)
| None
| IS 3039 (1988) |
Specification for structural steel for construction of hulls of ships (Second Revision) |
- |
- View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl. 6.1, Table no 1 (carbon) |
- |
|
|
|
| Cl. 6.1, Table no 1 (Manganese) |
- |
|
|
|
| Cl. 6.1, Table no 1 (Silicon) |
- |
|
|
|
| Cl. 6.1, Table no 1 (Sulphur) |
- |
|
|
|
| Cl. 6.1, Table no 1 (Phosphorous) |
- |
|
|
|
| Cl. 6.1, Table no 1 (aluminium) |
- |
|
|
|
| Cl. 6.1, Table no 1 (Carbon +( Manganese / 6)) |
- |
|
|
|
|
- |
- Excluding Nb, V, Ti, Al |
| 12889 |
BIS, Northern Regional Laboratory (NRL)
| None
| IS 279 (1981) |
Specification for galvanized steel wire for telegraph and telephone purposes (Third Revision) |
- |
1800/- View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl. 6.1 Table 1 (Carbon ) |
- |
|
|
|
| Cl. 6.1 Table 1 (Manganese) |
- |
|
|
|
| Cl. 6.1 Table 1 (Sulphur) |
- |
|
|
|
| Cl. 6.1 Table 1 (Phosphorous) |
- |
|
|
|
| Cl. 6.1 Table 1 (Silicon) |
- |
|
|
|
| Cl. 6.1 Table 1 (Aluminium) |
- |
|
|
|
| Cl. 6.1 Table 1 (Copper) |
- |
|
|
|
|
- |
- Excluding Microalloying elements |
| 12890 |
BIS, Northern Regional Laboratory (NRL)
| None
| IS 2589 (1975) |
Specificaiton for hard drawn steel wire for upholstery springs (First Revision) |
- |
900 Chemical (partial facilities) View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl. 4.1 Table 1 (carbon) |
- |
|
|
|
| Cl. 4.1 Table 1 (Silicon) |
- |
|
|
|
| Cl. 4.1 Table 1 (Manganese) |
- |
|
|
|
| Cl. 4.1 Table 1 (Sulphur) |
- |
|
|
|
| Cl. 4.1 Table 1 (Phosphorous) |
- |
|
|
|
|
- |
- Excluding Microalloying elements |
| 12891 |
BIS, Northern Regional Laboratory (NRL)
| None
| IS 2404 (1993) |
Malt extract - Specification (Second Revision) |
- |
6600 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
No Record Found
|
|
- |
- Microbiological testing complete
Excluding Refractive Index, Reducing Sugar |
| 12892 |
BIS, Northern Regional Laboratory (NRL)
| None
| IS 2385 (1977) |
Specification for hot - Rolled mild steel sheet and strip in coil form for cold - Reduced tinplate and cold - Reduced blackplate (First Revision) |
- |
- View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl. 5.1, 5.2 (carbon) |
- |
|
|
|
| Cl. 5.1, 5.2 (Manganese) |
- |
|
|
|
| Cl. 5.1, 5.2 (Sulphur) |
- |
|
|
|
| Cl. 5.1, 5.2 (Phosphorus) |
- |
|
|
|
| Cl. 5.1, 5.2 (Nitrogen ) |
- |
|
|
|
| Cl. 5.1, 5.2 (aluminium) |
- |
|
|
|
| Cl. 5.1, 5.2 (copper) |
- |
|
|
|
| Cl. 5.1, 5.2 (silicon) |
- |
|
|
|
| Cl. 5.1, 5.2 (chromium) |
- |
|
|
|
|
- |
- Excluding Al, Cu, Cr |
| 12893 |
BIS, Northern Regional Laboratory (NRL)
| None
| IS 9294 (1979) |
Cold-Rolled Stainless Steel Strips for Razor Blades |
- |
1725/ View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4.1 (Carbon- appropriate parts of IS 228) |
- |
|
|
|
| 4.1 (Manganese- appropriate parts of IS 228) |
- |
|
|
|
| 4.1 (Silicon- appropriate parts of IS 228) |
- |
|
|
|
| 4.1 (Sulphur- appropriate parts of IS 228) |
- |
|
|
|
| 4.1 (Phosphorous- appropriate parts of IS 228) |
- |
|
|
|
| 4.1 (Chromium- appropriate parts of IS 228) |
- |
|
|
|
| 4.3 (Nickel- appropriate parts of IS 228) |
- |
|
|
|
| 4.3 (Molybdenum- appropriate parts of IS 228) |
- |
|
|
|
| 4.3 (Copper- appropriate parts of IS 229) |
- |
|
|
|
|
- |
- Excluding Microstructure, Hardness test, surface finish, Microalloying elements |
| 12894 |
BIS, Northern Regional Laboratory (NRL)
| None
| IS 8951 (2001) |
Steel cast billet ignots, billets and blooms for production of high carbon steel wire rods - Specification (First Revision) |
- |
- View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4,7.1 & 7.2 Table 1 (Carbon- IS 228 or any other established instrumental /Chemical method) |
- |
|
|
|
| 4,7.1 & 7.2 Table 1 (Manganese- IS 228 or any other established instrumental /Chemical method) |
- |
|
|
|
| 4,7.1 & 7.2 Table 1 (Silicon- IS 228 or any other established instrumental /Chemical method) |
- |
|
|
|
| 4,7.1 & 7.2 Table 1 (Sulphur- IS 228 or any other established instrumental /Chemical method) |
- |
|
|
|
| 4,7.1 & 7.2 Table 1 (Phosphorous- IS 228 or any other established instrumental /Chemical method) |
- |
|
|
|
| 4,7.1 & 7.2 Table 1 (Copper- IS 228 or any other established instrumental /Chemical method) |
- |
|
|
|
| 4,7.1 & 7.2 Table 1 (Nickel- IS 228 or any other established instrumental /Chemical method) |
- |
|
|
|
| 4,7.1 & 7.2 Table 1 (Chromium- IS 228 or any other established instrumental /Chemical method) |
- |
|
|
|
| 4,7.1 & 7.2 Table 1 (Nitrogen- IS 228 or any other established instrumental /Chemical method) |
- |
|
|
|
|
- |
- Excluding Cu, Ni, Cr |
| 12895 |
BIS, Northern Regional Laboratory (NRL)
| None
| IS 8917 (1978) |
Specification for steel plates for galvanizing pots |
- |
4850 View breakup
Complete testing charges
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Clause 5.1 (Silicon, Max.) |
- |
|
|
|
| Clause 5.1 (Phosphorous, Max.) |
- |
|
|
|
| Clause 5.1 (Sulphur) |
- |
|
|
|
| Clause 5.1 (Manganese) |
- |
|
|
|
| Clause 5.1 (Carbon) |
- |
|
|
|
|
- |
- Excluding Silicon |
| 12896 |
BIS, Northern Regional Laboratory (NRL)
| None
| IS 8748 (1978) |
Specification for forged/rolled CTC segments |
- |
Rs.1050/- View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Clause 3.1, Table 1 (Chromium) |
- |
|
|
|
| Clause 3.1, Table 1 (Nickel ) |
- |
|
|
|
| Clause 3.1, Table 1 (Phosphorous) |
- |
|
|
|
| Clause 3.1, Table 1 (Sulphur, Max) |
- |
|
|
|
| Clause 3.1, Table 1 (Manganese) |
- |
|
|
|
| Clause 3.1, Table 1 (Silicon, Max) |
- |
|
|
|
| Clause 3.1, Table 1 (Carbon) |
- |
|
|
|
|
- |
- Excluding Ni, Cr |
| 12897 |
BIS, Northern Regional Laboratory (NRL)
| None
| IS 8566 (1977) |
Specification for steel wire for reeds |
- |
- View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Clause 4.1 (Phosphorous, Max.) |
- |
|
|
|
| Clause 4.1 (Sulphur) |
- |
|
|
|
| Clause 4.1 (Carbon) |
- |
|
|
|
|
- |
- Test facility is complete |
| 12898 |
BIS, Northern Regional Laboratory (NRL)
| None
| IS 8565 (1977) |
Specification for heald wire |
- |
- View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Clause 4.1 (Phosphorous, Max.) |
- |
|
|
|
| Clause 4.1 (Sulphur) |
- |
|
|
|
| Clause 4.1 (Manganese) |
- |
|
|
|
| Clause 4.1 (Silicon) |
- |
|
|
|
| Clause 4.1 (Carbon) |
- |
|
|
|
|
- |
- Test facility is complete |
| 12899 |
BIS, Northern Regional Laboratory (NRL)
| None
| IS 8564 (1977) |
Specification for steel wire for nipples for spokes |
- |
- View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Clause 5.1 (Tellurium ) |
- |
|
|
|
| Clause 5.1 (Lead) |
- |
|
|
|
| Clause 5.1 (Phosphorous, Max.) |
- |
|
|
|
| Clause 5.1 (Sulphur) |
- |
|
|
|
| Clause 5.1 (Manganese) |
- |
|
|
|
| Clause 5.1 (Silicon, Max.) |
- |
|
|
|
| Clause 5.1 (Carbon) |
- |
|
|
|
|
- |
- Excluding Pb, Te |
| 12900 |
BIS, Northern Regional Laboratory (NRL)
| None
| IS 8563 (1977) |
Specification for half round mild steel wlRe for the manufacture of split pins |
- |
- View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Clause 5.1 (Phosphorous, Max.) |
- |
|
|
|
| Clause 5.1 (Sulphur, Max.) |
- |
|
|
|
| Clause 5.1 (Manganese) |
- |
|
|
|
| Clause 5.1 (Carbon, Max.) |
- |
|
|
|
|
- |
- Test facility is complete |