| 13201 |
BLUESKY LAB LLP, GHAZIABAD
| 8170306
| IS 10322 : Part 5 : Sec 5 (2013) |
Luminaires: Part 5 particular requirements: Sec 5 floodlights (First Revision) |
- |
55000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4(General Test Requireements) |
- |
500 |
|
10% discount offered to BIS |
| 5(Classification of Luminaires') |
- |
500 |
|
10% discount offered to BIS |
| 6.0(Marking) |
- |
1500 |
|
10% discount offered to BIS |
| 7.0(Construction) |
- |
8000 |
|
10% discount offered to BIS |
| 8.0(Creepage Distance and Clearances) |
- |
3000 |
|
10% discount offered to BIS |
| 9.0(Provision for earthing) |
- |
2500 |
|
10% discount offered to BIS |
| 10.0(Terminals) |
- |
2500 |
|
10% discount offered to BIS |
| 11.0(External & Internal Wiring) |
- |
5000 |
|
10% discount offered to BIS |
| 12.0(Protection against electric shock) |
- |
2500 |
|
10% discount offered to BIS |
| 13.0(Endurance Tests and Thermal Tests) |
- |
10000 |
|
10% discount offered to BIS |
| 14.0(Resistance to Dust & Moisture) |
- |
7000 |
|
10% discount offered to BIS |
| 15.0(Insulation Resistance and Electric Strength) |
- |
3000 |
|
10% discount offered to BIS |
| 16.0(Resistance to Heat , fire and tracking) |
- |
5000 |
|
10% discount offered to BIS |
| 17.0(Photometric Test) |
- |
25000 |
|
10% discount offered to BIS |
|
22 May, 2028 |
- Luminaries size restricted to 1000 mm for photometric test, UV Radiations as per C. 4
.24 & Annex P of IS 10322 (Part 1):2014, Short-circuit protection as per cl.4.26 IPX8 upto 1.3m |
| 13202 |
BLUESKY LAB LLP, GHAZIABAD
| 8170306
| IS 10322 : PART 5 : SEC 3 (2012) |
Luminaires: Part 5 particular requirements: Sec 3 luminaires for road and street lighting (First Revision) |
- |
55000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4(General Test Requireements) |
- |
500 |
|
10% discount offered to BIS |
| 5(Classification of Luminaires') |
- |
500 |
|
10% discount offered to BIS |
| 6.0(Marking) |
- |
1500 |
|
10% discount offered to BIS |
| 7.0(Construction) |
- |
8000 |
|
10% discount offered to BIS |
| 8.0(Creepage Distance and Clearances) |
- |
3000 |
|
10% discount offered to BIS |
| 9.0(Provision for earthing) |
- |
2500 |
|
10% discount offered to BIS |
| 10.0(Terminals) |
- |
2500 |
|
10% discount offered to BIS |
| 11.0(External & Internal Wiring) |
- |
5000 |
|
10% discount offered to BIS |
| 12.0(Protection against electric shock) |
- |
2500 |
|
10% discount offered to BIS |
| 13.0(Endurance Tests and Thermal Tests) |
- |
10000 |
|
10% discount offered to BIS |
| 14.0(Resistance to Dust & Moisture) |
- |
7000 |
|
10% discount offered to BIS |
| 15.0(Insulation Resistance and Electric Strength) |
- |
3000 |
|
10% discount offered to BIS |
| 16.0(Resistance to Heat , fire and tracking) |
- |
5000 |
|
10% discount offered to BIS |
| 17.0(Photometric Test) |
- |
25000 |
|
10% discount offered to BIS |
|
22 May, 2028 |
- Luminaries size restricted to 1000 mmfor photometric test, UV Radiations as per C. 4
.24 & Annex P of IS 10322 (Part 1):2014, Short-circuit protection as per cl.4.26 IPX8 upto 1.3m |
| 13203 |
BLUESKY LAB LLP, GHAZIABAD
| 8170306
| IS 10322 : Part 5 : Sec 2 (2012) |
Luminaires: Part 5 particular requirements: Sec 2 recessed luminaires (First Revision) |
- |
55000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4(General Test Requireements) |
- |
500 |
|
10% discount offered to BIS |
| 5(Classification of Luminaires') |
- |
500 |
|
10% discount offered to BIS |
| 6(Marking) |
- |
1500 |
|
10% discount offered to BIS |
| 7(Construction) |
- |
8000 |
|
10% discount offered to BIS |
| 8(Creepage Distance and Clearances) |
- |
3000 |
|
10% discount offered to BIS |
| 9(Provision for earthing) |
- |
2500 |
|
10% discount offered to BIS |
| 10(Terminals) |
- |
2500 |
|
10% discount offered to BIS |
| 11(External & Internal Wiring) |
- |
5000 |
|
10% discount offered to BIS |
| 12(Protection against electric shock) |
- |
2500 |
|
10% discount offered to BIS |
| 13(Endurance Tests and Thermal Tests) |
- |
10000 |
|
10% discount offered to BIS |
| 14(Resistance to Dust and Moisture) |
- |
7000 |
|
10% discount offered to BIS |
| 15(Insulation Resistance and Electric Strength) |
- |
3000 |
|
10% discount offered to BIS |
| 16(Resistance to Heat , fire and tracking) |
- |
5000 |
|
10% discount offered to BIS |
| 17(Photometric Test) |
- |
25000 |
|
10% discount offered to BIS |
|
22 May, 2028 |
- Luminaries size restricted to 1000 mm for photometric test, UV Radiations as per C. 4
.24 & Annex P of IS 10322 (Part 1):2014, Short-circuit protection as per cl.4.26 IPX8 upto 1.3m |
| 13204 |
BLUESKY LAB LLP, GHAZIABAD
| 8170306
| IS 16102 : Part 1 (2012) |
Self - Ballasted led lamps for general lighting services: Part 1 safety requirements |
- |
40000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 5(Marking) |
- |
1500 |
|
10% discount offered to BIS |
| 6(Interchangeability) |
- |
3000 |
|
10% discount offered to BIS |
| 7(Protection against accidental contact with live parts) |
- |
2000 |
|
10% discount offered to BIS |
| 8(Insulation Resistance and Electric Strength) |
- |
10000 |
|
10% discount offered to BIS |
| 9(MECHANICAL STRENGTH) |
- |
2500 |
|
10% discount offered to BIS |
| 10(cap temperature) |
- |
5000 |
|
10% discount offered to BIS |
| 11(Resistance to Heat) |
- |
4000 |
|
10% discount offered to BIS |
| 12(Resistance to Flame and Ignition) |
- |
5500 |
|
10% discount offered to BIS |
| 13(Fault conditions) |
- |
6500 |
|
10% discount offered to BIS |
| 14(Creepage distance and clearances) |
- |
5500 |
|
10% discount offered to BIS |
| Annex A(Ovreview of systems composed of LED modules and control gear) |
- |
400 |
|
10% discount offered to BIS |
| Annex B(Lamps with operating position limitations) |
- |
400 |
|
10% discount offered to BIS |
| 15(Selection of lamps for tests (Sampling)) |
- |
500 |
|
10% discount offered to BIS |
| 16(Condition of compliance) |
- |
400 |
|
10% discount offered to BIS |
| 17(Tests) |
- |
200 |
|
10% discount offered to BIS |
|
22 May, 2028 |
- Restricted only to Cap type B22d, E14 & E27 |
| 13205 |
BIS, Central Laboratory (CL)
| None
| IS 3903 (1984) |
Specification for dimethoate emulsifiable concentrates |
- |
Rs. 3300.00/- View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 2.3.2 (Acidity) |
- |
|
|
|
| 2.3.1 (Dimethoate Content, NV upto 9) |
- |
|
|
|
| 2.3.1 (Dimethoate Content, NV above 50) |
- |
|
|
|
| 2.2.3 (Flash Point) |
- |
|
|
|
| 2.1 (Constituents) |
- |
|
|
|
| 2.2.1 (Description) |
- |
|
|
|
| 2.2.2 (Cold Test) |
- |
|
|
|
| 2.2.4 (emulsion Stability) |
- |
|
|
|
| 2.2.5 (Heat Stability) |
- |
|
|
|
| 2.2.4 (emulsion Stability) |
- |
|
|
|
| 2.2.5 (Heat Stability) |
- |
|
|
|
| 2.3.1 (Dimethoate Content, NV above 9 and below 50) |
- |
|
|
|
|
- |
- EXCLUDING Cl. 2.3.1 Dimethoate Content; |
| 13206 |
BLUESKY LAB LLP, GHAZIABAD
| 8170306
| IS 366 (1991) |
Electric iron - Specification (Fourth Revision) |
- |
15000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 10.0(Measurement of Heating up time) |
- |
500 |
|
10% discount offered to BIS |
| 11.0(Measurement of sole plate temperature) |
- |
500 |
|
10% discount offered to BIS |
| 12.0(Measurement of Tempearture Distribution) |
- |
700 |
|
10% discount offered to BIS |
| 13.0(Measurement of Initial overswing temperature and Heating up excess temperature) |
- |
500 |
|
10% discount offered to BIS |
| 14.0(Measurement of Cyclic fluctuation of temperature of hottest point ) |
- |
1000 |
|
10% discount offered to BIS |
| 16.0(Measurement of Thermostatic staibility) |
- |
1000 |
|
10% discount offered to BIS |
| 17(Measurement of Thermostatic staibility) |
- |
500 |
|
10% discount offered to BIS |
| 7.0(Classification (as per Cl.6 of IS 302-2-3 and Cl.6.1 of IS 302-1)) |
- |
100 |
|
10% discount offered to BIS |
| 7.0(Classification (as per Cl.6 of IS 302-2-3 and Cl.6.2 of IS 302-1)) |
- |
100 |
|
10% discount offered to BIS |
| 9.0(Protection against access to live parts (as per Cl. 8 of IS 302-2-3 and IS 302-1)) |
- |
800 |
|
10% discount offered to BIS |
| 9.0(Power input and current (as per Cl. 10 of IS 302-2-3 and IS 302-1)) |
- |
400 |
|
10% discount offered to BIS |
| 9.0(Temperature Rise (as per Cl. 11 of IS 302-2-3 and IS 302-1)) |
- |
900 |
|
10% discount offered to BIS |
| 9.0(Leakage current and Electric Strength at Operating Temperature (as per Cl. 13 of IS 302-2-3 and IS 302-1)) |
- |
500 |
|
10% discount offered to BIS |
| 9.0(Transient Overvoltage (as per of Cl. 14 of IS 302-2-3 and Table 6 of IS 302-1)) |
- |
1000 |
|
10% discount offered to BIS |
| 9.0(Moisture Resistance (as per of Cl.15 of IS 302-2-3 and IS 302-1)) |
- |
1500 |
|
10% discount offered to BIS |
| 9.0(Abnormal Operation (as per of Cl.19 of IS 302-2-3 and IS 302-1) ) |
- |
1000 |
|
10% discount offered to BIS |
| 9.0(Staibilty and mechanical hazards (as per of Cl.20 of IS 302-2-3 and IS 302-1) ) |
- |
1000 |
|
10% discount offered to BIS |
| 9.0(Mechanical strength (as per of Cl.21 of IS 302-2-3 and IS 302-1) ) |
- |
500 |
|
10% discount offered to BIS |
| 9.0(Construction (as per of Cl.22 of IS 302-2-3 and IS 302-1) ) |
- |
500 |
|
10% discount offered to BIS |
| 9.0(Internal wiring (as per of Cl.23 of IS 302-2-3 and IS 302-1) ) |
- |
500 |
|
10% discount offered to BIS |
| 9.0(Components (as per of Cl.24 of IS 302-2-3 and IS 302-1) ) |
- |
500 |
|
10% discount offered to BIS |
| 9.0(Supply connection and external flexible cord (as per of Cl.25 of IS 302-2-3 and IS 302-1) ) |
- |
400 |
|
10% discount offered to BIS |
| 9.0(Terminals for external conductors (as per of Cl.26 of IS 302-2-3 and IS 302-1) ) |
- |
300 |
|
10% discount offered to BIS |
| 9.0(Provision for earthing (as per of Cl.27 of IS 302-2-3 and IS 302-1) ) |
- |
1000 |
|
10% discount offered to BIS |
| 9.0(Screw and connections (as per of Cl.28 of IS 302-2-3 and IS 302-1)) |
- |
300 |
|
10% discount offered to BIS |
| 9.0(Clearances, creepage distances and solid insulation (as per of Cl.29 of IS 302-2-3 and IS 302-1)) |
- |
800 |
|
10% discount offered to BIS |
| 9.0(Resistance to Heat and Fire (as per of Cl.30 of IS 302-2-3 and IS 302-1)) |
- |
1000 |
|
10% discount offered to BIS |
| 9.0(Resistance to Rusting (as per of Cl.31 of IS 302-2-3 and IS 302-1)) |
- |
800 |
|
10% discount offered to BIS |
| 9.0(Leakage current and Electric Strength at Operating Temperature (as per Cl. 13 of IS 302-2-3 and IS 302-1)) |
- |
1000 |
|
10% discount offered to BIS |
| 16 of IS 302-2-3(Leakage current electric strength) |
- |
500 |
|
10% discount offered to BIS |
| 15(MEASUREMENT OF TEMPERATURE DROP UNDER LOAD) |
- |
100 |
|
10% discount offered to BIS |
|
22 May, 2028 |
- Abnormal operation (Cl.19.11.4.1 to 19.11.4.4 |
| 13207 |
BLUESKY LAB LLP, GHAZIABAD
| 8170306
| IS 302 : Part 2 : Sec 3 (2007) |
Safety of household and similar electrical appliances: Part 2 particular requirements: Sec 3 electric iron (First Revision) |
- |
12495 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 6(Classification- IS 302-1 ) |
- |
100 |
|
10% discount offered to BIS |
| 7.14(Marking- IS 302-1) |
- |
500 |
|
10% discount offered to BIS |
| 8( Protection Against Electric Shock, IS 302-1) |
- |
800 |
|
10% discount offered to BIS |
| 10(Power Input and Current, IS 302-1) |
- |
400 |
|
10% discount offered to BIS |
| 11(Heating, IS 302-1) |
- |
900 |
|
10% discount offered to BIS |
| 13(Electrical Insulation and Leakage Current at Operating Temperature: Leakage current, IS 302-1) |
- |
500 |
|
10% discount offered to BIS |
| 14(Transient Over Voltages, IS 302-1) |
- |
1000 |
|
10% discount offered to BIS |
| 15.2(Moisture Resistance, IS 302-1) |
- |
1200 |
|
10% discount offered to BIS |
| 16(Electrical Insulation and Leakage Current at Operating Temperature: Leakage current, IS 302-1) |
- |
1000 |
|
10% discount offered to BIS |
| 19.4(Abnormal Operation, IS 302-1) |
- |
800 |
|
10% discount offered to BIS |
| 20.1(Stability & Mechanical Hazards, IS 302-1) |
- |
400 |
|
10% discount offered to BIS |
| 20.2(Stability & Mechanical Hazards, IS 302-1) |
- |
400 |
|
10% discount offered to BIS |
| 21.1(Mechanical Strength, IS 302-1) |
- |
400 |
|
10% discount offered to BIS |
| 21.2(Mechanical Strength, IS 302-1) |
- |
400 |
|
10% discount offered to BIS |
| 22(Construction, IS 302-1) |
- |
300 |
|
10% discount offered to BIS |
| 22.101(Construction) |
- |
300 |
|
10% discount offered to BIS |
| 23.1(Internal Wiring, IS 302-1) |
- |
400 |
|
10% discount offered to BIS |
| 24.1(Components, IS 302-1) |
- |
500 |
|
10% discount offered to BIS |
| 25.1(Supply Connection and External Flexible Cords, IS 302-1) |
- |
400 |
|
10% discount offered to BIS |
| 26(Terminals for External Conductors, IS 302-1) |
- |
300 |
|
10% discount offered to BIS |
| 27.1(Provision for Earthing, IS 302-1) |
- |
400 |
|
10% discount offered to BIS |
| 28(Screws & Connections, IS 302-1) |
- |
300 |
|
10% discount offered to BIS |
| 29.1(Clearances, Creepage distances and Solid Insulation, IS 302-1) |
- |
500 |
|
10% discount offered to BIS |
| 30.1(Resistance to Heat, Fire & Tracking, IS 302-1) |
- |
1000 |
|
10% discount offered to BIS |
| 31(Resistance of Rusting, IS 302-1) |
- |
800 |
|
10% discount offered to BIS |
| 32(Radiation, Toxicity and similar Hazard IS 302-1) |
- |
0.0 |
|
- |
| 7.1(Marking- IS 302-1) |
- |
100 |
|
10% discount offered to BIS |
| 7.3(Marking- IS 302-1) |
- |
0.0 |
|
- |
| 7.4(Marking- IS 302-1) |
- |
0.0 |
|
- |
| 7.6(Marking- IS 302-1) |
- |
0.0 |
|
- |
| 7.7(Marking- IS 302-1) |
- |
0.0 |
|
- |
| 7.8(Marking- IS 302-1) |
- |
0.0 |
|
- |
| 7.11(Marking- IS 302-1) |
- |
0.0 |
|
- |
| 7.12(Marking- IS 302-1) |
- |
0.0 |
|
- |
| 7.13(Marking- IS 302-1) |
- |
0.0 |
|
- |
| 7.15(Marking- IS 302-1) |
- |
0.0 |
|
- |
| 7.101(Marking) |
- |
0.0 |
|
- |
| 15.3(Moisture Resistance, IS 302-1) |
- |
500 |
|
10% discount offered to BIS |
| 13(Electrical Insulation and Leakage Current at Operating Temperature: High Voltage, IS 302-1) |
- |
500 |
|
10% discount offered to BIS |
| 15.1(Moisture Resistance, IS 302-1) |
- |
500 |
|
10% discount offered to BIS |
| 16(Electrical Insulation and Leakage Current at Operating Temperature: High Voltage, IS 302-1) |
- |
400 |
|
10% discount offered to BIS |
| 19.5(Abnormal Operation, IS 302-1) |
- |
1000 |
|
10% discount offered to BIS |
| 19.7(Abnormal Operation) |
- |
500 |
|
10% discount offered to BIS |
| 19.9(Abnormal Operation) |
- |
500 |
|
10% discount offered to BIS |
| 21.101(Mechanical Strength, IS 302-2-3) |
- |
200 |
|
10% discount offered to BIS |
| 22.102(Construction) |
- |
200 |
|
10% discount offered to BIS |
| 22.103(Construction) |
- |
200 |
|
10% discount offered to BIS |
| 22.104(Construction) |
- |
200 |
|
10% discount offered to BIS |
| 22.105(Construction) |
- |
200 |
|
10% discount offered to BIS |
| 22.106(Construction) |
- |
200 |
|
10% discount offered to BIS |
| 22.107(Construction) |
- |
200 |
|
10% discount offered to BIS |
| 23.2(Internal Wiring, IS 302-1) |
- |
300 |
|
10% discount offered to BIS |
| 23.3(Internal Wiring, IS 302-1) |
- |
300 |
|
10% discount offered to BIS |
| 23.4(Internal Wiring, IS 302-1) |
- |
300 |
|
10% discount offered to BIS |
| 23.5(Internal Wiring, IS 302-1) |
- |
300 |
|
10% discount offered to BIS |
| 23.6(Internal Wiring, IS 302-1) |
- |
300 |
|
10% discount offered to BIS |
| 23.7(Internal Wiring, IS 302-1) |
- |
300 |
|
10% discount offered to BIS |
| 23.8(Internal Wiring, IS 302-1) |
- |
300 |
|
10% discount offered to BIS |
| 23.9(Internal Wiring, IS 302-1) |
- |
300 |
|
10% discount offered to BIS |
| 23.10(Internal Wiring, IS 302-1) |
- |
300 |
|
10% discount offered to BIS |
| 24.2(Components, IS 302-1) |
- |
400 |
|
10% discount offered to BIS |
| 24.4(Components, IS 302-1) |
- |
400 |
|
10% discount offered to BIS |
| 25.5(Supply Connection and External Flexible Cords, IS 302-1) |
- |
300 |
|
10% discount offered to BIS |
| 25.6(Supply Connection and External Flexible Cords, IS 302-1) |
- |
300 |
|
10% discount offered to BIS |
| 25.7(Supply Connection and External Flexible Cords, IS 302-1) |
- |
300 |
|
10% discount offered to BIS |
| 25.8(Supply Connection and External Flexible Cords, IS 302-1) |
- |
300 |
|
10% discount offered to BIS |
| 26.9(Supply Connection and External Flexible Cords, IS 302-1) |
- |
300 |
|
10% discount offered to BIS |
| 25.1(Supply Connection and External Flexible Cords, IS 302-1) |
- |
300 |
|
10% discount offered to BIS |
| 25.11(Supply Connection and External Flexible Cords, IS 302-1) |
- |
300 |
|
10% discount offered to BIS |
| 25.12(Supply Connection and External Flexible Cords, IS 302-1) |
- |
300 |
|
10% discount offered to BIS |
| 25.13(Supply Connection and External Flexible Cords, IS 302-1) |
- |
300 |
|
10% discount offered to BIS |
| 25.14(Supply Connection and External Flexible Cords, IS 302-1) |
- |
300 |
|
10% discount offered to BIS |
| 25.15(Supply Connection and External Flexible Cords, IS 302-1) |
- |
300 |
|
10% discount offered to BIS |
| 25.16(Supply Connection and External Flexible Cords, IS 302-1) |
- |
300 |
|
10% discount offered to BIS |
| 25.17(Supply Connection and External Flexible Cords, IS 302-1) |
- |
300 |
|
10% discount offered to BIS |
| 25.18(Supply Connection and External Flexible Cords, IS 302-1) |
- |
300 |
|
10% discount offered to BIS |
| 25.19(Supply Connection and External Flexible Cords, IS 302-1) |
- |
300 |
|
10% discount offered to BIS |
| 25.2(Supply Connection and External Flexible Cords, IS 302-1) |
- |
300 |
|
10% discount offered to BIS |
| 25.21(Supply Connection and External Flexible Cords, IS 302-1) |
- |
400 |
|
10% discount offered to BIS |
| 25.22(Supply Connection and External Flexible Cords, IS 302-1) |
- |
400 |
|
10% discount offered to BIS |
| 27.2(Provision for Earthing, IS 302-1) |
- |
500 |
|
10% discount offered to BIS |
| 27.3(Provision for Earthing, IS 302-1) |
- |
500 |
|
10% discount offered to BIS |
| 27.4(Provision for Earthing, IS 302-1) |
- |
500 |
|
10% discount offered to BIS |
| 27.5(Provision for Earthing, IS 302-1) |
- |
500 |
|
10% discount offered to BIS |
| 29.2(Clearances, Creepage distances and Solid Insulation, IS 302-1) |
- |
600 |
|
10% discount offered to BIS |
| 30.2(Resistance to Heat, Fire & Tracking, IS 302-1) |
- |
900 |
|
10% discount offered to BIS |
| 19.11.4.4(Surge immunity test) |
- |
2000 |
|
10% discount offered to BIS |
|
22 May, 2028 |
- Exclusions: EMI/EMC tests (electrostatic Discharges, Radiant Fields, Fast Transient burst,
Voltage surges, Injected current, voltage dips & Interruptions, Mains signals)
[cl.19.11.4.1 to Cl.19.11.4.7], Radiation, Toxicity & Similar Hazards (cl.32), Components (Cl.24) |
| 13208 |
BLUESKY LAB LLP, GHAZIABAD
| 8170306
| IS 302 : Part 2 : Sec 201 (2008) |
Safety of household and similar electrical appliances: Part 2 particular requirements: Sec 201 electric immersion water heaters (First Revision) |
- |
13969 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl.6 of IS 302-‐2-‐201:2008(Classification) |
- |
500 |
|
10% discount offered to BIS |
| Cl.7 of IS 302-2-201:2008(Marking and Instruction ) |
- |
600 |
|
10% discount offered to BIS |
| Cl.8 of IS 302‐2-201: 2008(Protection Against Access to Live Parts) |
- |
800 |
|
10% discount offered to BIS |
| Cl.10 of IS 302‐2‐201:2008(Power Input and Current ) |
- |
1200 |
|
10% discount offered to BIS |
| Cl.11 of IS 302-2201: 2008(Heating) |
- |
1100 |
|
10% discount offered to BIS |
| Cl.13 of IS 302-2-201: 2008(Leakage Current & Electric Strength at Operating Temperature) |
- |
700 |
|
10% discount offered to BIS |
| Cl.14 of IS 302‐2-201:2008(Transient Over Voltages ) |
- |
900 |
|
10% discount offered to BIS |
| Cl.15 of IS 302-2-201:2008(Moisture Resistance ) |
- |
1200 |
|
10% discount offered to BIS |
| Cl.16 of IS 302-2-201:2008(Leakage Current & Electric Strength) |
- |
1400 |
|
10% discount offered to BIS |
| Cl.17 of IS 302‐2-201: 2008(Overload Protection of Transformers & Associated Circuits) |
- |
700 |
|
10% discount offered to BIS |
| Cl.19 of IS 302‐2-201: 2008(Abnormal Operation ) |
- |
1500 |
|
10% discount offered to BIS |
| Cl.20 of IS 302-2-201: 2008(Stability & Mechanical Hazards) |
- |
500 |
|
10% discount offered to BIS |
| Cl.21 of IS 302-2-201: 2008(Mechanical Strength ) |
- |
400 |
|
10% discount offered to BIS |
| Cl.22 of IS 302-2-201: 2008(Construction) |
- |
400 |
|
10% discount offered to BIS |
| Cl.23 of 302-2-201:2008(Internal Wiring ) |
- |
500 |
|
10% discount offered to BIS |
| Cl.24 of IS 302-2-201: 2008(Component) |
- |
400 |
|
10% discount offered to BIS |
| Cl.25 of IS 302-2-201: 2008(Supply Connection and External Flexible Cords) |
- |
600 |
|
10% discount offered to BIS |
| Cl.26 of IS 302-2-201: 2008(Terminals for External Conductors) |
- |
400 |
|
10% discount offered to BIS |
| Cl.27 of IS 302-2-201: 2008(Provision for Earthing ) |
- |
600 |
|
10% discount offered to BIS |
| Cl.28 of IS 302-2-201: 2008(Screws & Connections ) |
- |
400 |
|
10% discount offered to BIS |
| Cl.29 of IS 302-2‐201:2008(Clearances, Creepage Distances and Solid Insulation ) |
- |
600 |
|
10% discount offered to BIS |
| Cl.30 of IS 302-2‐201:2008(Resistance to Heat and Fire ) |
- |
1200 |
|
10% discount offered to BIS |
| Cl.31 of IS 302-2-201:2008(Resistance of Rusting ) |
- |
700 |
|
10% discount offered to BIS |
| 19.11.4.4(Surge immunity test) |
- |
2000 |
|
10% discount offered to BIS |
|
22 May, 2028 |
- Restricted Upto 5KW EMI/EMC tests (Electrostatic discharges, radiant fields, fast transient bursts, voltage
surges, injected current, voltage dip and interruption, mains signals) (Cl.19.11.4.1 to
19.11.4.7), Components (Capacitors for radio interference suppression, isolating
transformer, coupler) (Cl.24.1.1, 24.1.2, 24.1.5) cl.22.16 automatic cord reel, cl
22.32 test on ceramic materials cl.22.46 software |
| 13209 |
BLUESKY LAB LLP, GHAZIABAD
| 8170306
| IS 16242 : Part 1 (2014) |
Uninterruptible power systems (UPS): Part 1 general and safety requirements for UPS |
- |
75000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4.5(Components) |
- |
500 |
|
10% discount offered to BIS |
| 4.6(Power interface) |
- |
1500 |
|
10% discount offered to BIS |
| 4.7(Marking & instructions) |
- |
1000 |
|
10% discount offered to BIS |
| 5.1(Protection against shock and energy hazards) |
- |
1000 |
|
10% discount offered to BIS |
| 5.2(Requirement of auxiliary circuits) |
- |
2000 |
|
10% discount offered to BIS |
| 5.3(Protective earthing and bonding) |
- |
1500 |
|
10% discount offered to BIS |
| 5.4(AC and DC power isolation) |
- |
1500 |
|
10% discount offered to BIS |
| 5.5(Over current and earth fault condition) |
- |
2000 |
|
10% discount offered to BIS |
| 5.6(Safety interlocks) |
- |
2500 |
|
10% discount offered to BIS |
| 5.7(CLEARANCES, CREEPAGE DISTANCES AND SOLID INSULATION) |
- |
5000 |
|
10% discount offered to BIS |
| 6.1(Wiring, connections and supply) |
- |
500 |
|
10% discount offered to BIS |
| 6.2(Connection to power) |
- |
2000 |
|
10% discount offered to BIS |
| 6.3(Wiring terminals for external power conductors) |
- |
1500 |
|
10% discount offered to BIS |
| 7.1(Enclosure) |
- |
3000 |
|
10% discount offered to BIS |
| 7.2(STABILITY) |
- |
3000 |
|
10% discount offered to BIS |
| 7.3(MECHANICAL STRENGTH) |
- |
15000 |
|
10% discount offered to BIS |
| 7.4(Construction details) |
- |
3000 |
|
10% discount offered to BIS |
| 7.6(Battery location) |
- |
2000 |
|
10% discount offered to BIS |
| 7.7(Temperature rise) |
- |
8000 |
|
10% discount offered to BIS |
| 8.1(General procision for earth leakage) |
- |
1500 |
|
10% discount offered to BIS |
| 8.2(Electric Strength) |
- |
5000 |
|
10% discount offered to BIS |
| 8.3(Abnormal operating and fault conditions) |
- |
8000 |
|
10% discount offered to BIS |
| 9.0(Connection to telecommunication networks) |
- |
6000 |
|
10% discount offered to BIS |
| 7.5(Resistance to fire) |
- |
5000 |
|
10% discount offered to BIS |
| 4.5/RD 1.5(Components) |
- |
500 |
|
10% discount offered to BIS |
|
22 May, 2028 |
- Exclusions: Restricted upto 10Kva Single Phase only. Excluding: Components (Cl.4.5/ RD, CI.
1.5), Winding Wires (Cl. 2.10.5.3), Semiconductor Devices (Cl. 2.10.5.4),
SMPS/Main transformer (cl.2.10.5.11); PCB Material (cl.2.10.6); SMPS/ Mains
Transformer (Cl. 2.10.5.11), Wire in wound components (Cl. 2.10.5.12), Wire with
solvent based enamel in wound components (Cl. 2.10.5.13), Additional
insulation in wound components (Cl. 2.10.5.14), Tests for pollution degree 1
environment & for insulating compound (Cl. 2.10.10), Tests for semiconductor
devices & for cemented joints (Cl. 2.10.11), Enclosed & sealed parts (Cl. 2.10.12),
Internal Wire (Cl. 3.1.4), Batteries (Cl.4.3.8), Non-rewirable Plug with PVC
Sheathed Cable (Cl. 3.2.5), Construction of printed circuit boards (Cl.5.7/RD/2.10.6),
Wiring, connection and supply (Cl.6.1.1/RD 3.1.4), Batteries (Cl. 4.3.8), Performance Tests: Simulators (ESD/EFT/Voltage Dip Interruption/PFMF), Gas Concentration, Ventilation of Battery Compartments (Cl.7.4.3, Cl.7.6.7 & Annex- M), Non-rewirable plug with PVC sheathed cable (Cl.3.2.5), Performance tests:simulators immunity to Low frequency signals (Annex L.5.2 (IEC 32040-2,CI.7.3)). Switches & Relays (cl.5.6.1 / RD cl.2.8.7); Insulating Conductors (cl.6.1.1/RD
cl.3.1.4) |
| 13210 |
BLUESKY LAB LLP, GHAZIABAD
| 8170306
| IS 15885 : Part 2 : Sec 13 (2012) |
Safety of lamp controlgear: Part 2 particular requirements: Sec 13 d.c. or a.c. supplied electronic controlgear for led modules |
- |
45000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 7(Marking) |
- |
1500 |
|
10% discount offered to BIS |
| 8(Protection against accidental contact with live parts) |
- |
2500 |
|
10% discount offered to BIS |
| 9(Terminals) |
- |
2000 |
|
10% discount offered to BIS |
| 10(PROVISION FOR EARTHING) |
- |
2500 |
|
10% discount offered to BIS |
| 11(MOISTURE RESISTANCE) |
- |
8000 |
|
10% discount offered to BIS |
| 12(Electric Strength) |
- |
2000 |
|
10% discount offered to BIS |
| 13(Thermal endurance test for winding of ballasts) |
- |
5000 |
|
10% discount offered to BIS |
| 14(Fault conditions) |
- |
5000 |
|
10% discount offered to BIS |
| 16(Construction) |
- |
5000 |
|
10% discount offered to BIS |
| 17(Creepage distance and clearances) |
- |
2500 |
|
10% discount offered to BIS |
| 18(Screws, current carrying parts and connections) |
- |
2000 |
|
10% discount offered to BIS |
| 19(Resistance to heat, fire and tracking) |
- |
4000 |
|
10% discount offered to BIS |
| 20(Resistance to corrosion) |
- |
3000 |
|
10% discount offered to BIS |
| 15.4 (b)(Cold impact) |
- |
0.00 |
|
10% discount offered to BIS |
| 15(Transformer heating) |
- |
1200 |
|
10% discount offered to BIS |
|
22 May, 2028 |
- Components: enclosures (Cl.16), Bridging resistor in primary circuit (Cl.16), capacitor
an RC units (Cl.16), RF suppression (X-Y capacitors) (Cl.16), Inductor (Cl.16), MOV/VDR (CI.16), SMPS/Mains Transformer (cl.16); PCB material (cl.16); Metal base PCB for LED (cl.19);
Transparent cover (Cl.19), Bobbin (Cl.19), Insulated tape (Cl.16), heat shrinkage
cleeve (Cl.16), connector (Cl.16), Fuse (Cl.16), Internal wire (Cl.16), LED (Cl.16), opto-coupler (CI.16), EMI/EMC filter (Cl.16), Winding wire (Cl.16), Thin sheet materials (Cl.16) |
| 13211 |
BIS, Eastern Regional Laboratory (ERL)
| None
| IS 16644 (2018) |
Stress - Relieved, low relaxation steel wire for prestressed concrete - Specification |
- |
- View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Clause 5.1.1 (Sulphur) |
- |
|
|
|
| Clause 5.1.1 (Phosphorus) |
- |
|
|
|
|
- |
- Except 8.7 Stress relaxation, 8.8 Fatigue test |
| 13212 |
BLUESKY LAB LLP, GHAZIABAD
| 8170306
| IS 13252 : Part 1 (2010) |
Information technology equipment - Safety: Part 1 general requirements (Second Revision) |
- |
40000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 1.5(Components) |
- |
500 |
|
10% discount offered to BIS |
| 1.6(Power interface .) |
- |
1500 |
|
10% discount offered to BIS |
| 1.7(Markings and instructions) |
- |
1000 |
|
10% discount offered to BIS |
| 2.1(Protection from electric shock and energy hazards) |
- |
1000 |
|
10% discount offered to BIS |
| 2.2(SELV circuits) |
- |
1500 |
|
10% discount offered to BIS |
| 2.3(TNV circuits) |
- |
2000 |
|
10% discount offered to BIS |
| 2.4(Limited current circuits) |
- |
2000 |
|
10% discount offered to BIS |
| 2.5(Limited power sources .) |
- |
2500 |
|
10% discount offered to BIS |
| 2.6(Provisions for earthing and bonding) |
- |
1500 |
|
10% discount offered to BIS |
| 2.8(Safety interlocks) |
- |
3000 |
|
10% discount offered to BIS |
| 2.9(Electrical insulation) |
- |
5000 |
|
10% discount offered to BIS |
| 2.10(Clearances, creepage distances and distances through insulation) |
- |
5000 |
|
10% discount offered to BIS |
| 3.1(General) |
- |
500 |
|
10% discount offered to BIS |
| 3.2(Connection to a mains supply) |
- |
2000 |
|
10% discount offered to BIS |
| 3.3(Wiring terminals for connection of external conductors) |
- |
1500 |
|
10% discount offered to BIS |
| 3.4(Disconnection from the mains supply) |
- |
1000 |
|
10% discount offered to BIS |
| 3.5(Interconnection of equipment) |
- |
1000 |
|
10% discount offered to BIS |
| 4.1(Stability) |
- |
3000 |
|
10% discount offered to BIS |
| 4.2(Mechanical strength) |
- |
1500 |
|
10% discount offered to BIS |
| 4.3(Design and construction) |
- |
3000 |
|
10% discount offered to BIS |
| 4.4(Protection against hazardous moving parts) |
- |
5000 |
|
10% discount offered to BIS |
| 4.5(Thermal requirements) |
- |
8000 |
|
10% discount offered to BIS |
| 4.6(Openings in enclosures) |
- |
3000 |
|
10% discount offered to BIS |
| 4.7(Resistance to fire) |
- |
5000 |
|
10% discount offered to BIS |
| 5.1(Touch current and protective conductor curren) |
- |
3500 |
|
10% discount offered to BIS |
| 5.2(Electric strength) |
- |
5000 |
|
10% discount offered to BIS |
| 5.3(Abnormal operating and fault conditions) |
- |
8000 |
|
10% discount offered to BIS |
| 6.1(Protection of telecommunication network service persons, and users of other equipment connected to the network, from hazards in the equipment) |
- |
2000 |
|
10% discount offered to BIS |
| 6.2(Protection of equipment users from overvoltages on networks telecommunication) |
- |
2500 |
|
10% discount offered to BIS |
| 6.3(Protection of the telecommunication wiring system from overheating) |
- |
2000 |
|
10% discount offered to BIS |
| 7.1(General) |
- |
500 |
|
10% discount offered to BIS |
| 7.2(Protection of cable distribution system service persons, and users of other equipment connected to the system, from hazardous voltages in the equipment) |
- |
1000 |
|
10% discount offered to BIS |
| 7.3(Protection of equipment users from overvoltages on the cable distribution system) |
- |
2000 |
|
10% discount offered to BIS |
| 7.4(Insulation between primary circuits and cable distribution systems) |
- |
3000 |
|
10% discount offered to BIS |
| 2.7(Overcurrent and earth fault protection in primary circuits) |
- |
1100 |
|
10% discount offered to BIS |
| Annex A3(Hot flaming oil test) |
- |
2500 |
|
10% discount offered to BIS |
| Annex C(Transformers) |
- |
1200 |
|
- |
| Annex B(Motor tests under abnormal conditions) |
- |
1500 |
|
10% discount offered to BIS |
| Annex K(Thermal Control) |
- |
800 |
|
10% discount offered to BIS |
| Annex Q(Voltage Dependent Resistors) |
- |
500 |
|
10% discount offered to BIS |
| Annex U(Insulating winding wires for use without interleaved insulation) |
- |
500 |
|
10% discount offered to BIS |
| Annex CC(Evaluation of integrated circuit (IC) current limiters) |
- |
500 |
|
10% discount offered to BIS |
| Annex DD(Requirements for the mounting means of a rack mounted equipment) |
- |
1100 |
|
10% discount offered to BIS |
| Annex EE(Household and home/ office document/ media shredders) |
- |
500 |
|
10% discount offered to BIS |
|
22 May, 2028 |
- Excluding: Component (Cl.1.5), Moving parts (Cl.2.8.5),Semiconductor devices (Cl.2.10.5.4), Insulation in wound component (Cl.2.10.5.11), Wire in wound component (Cl.2.10.5.12), Wire with solvent based enamel in wound components (Cl.2.10.5.13), Additional insulation in wound components (Cl.2.10.5.14), Test on coated printed boards and coated components (Cl.2.10.8.1), Test for Pollution Degree 1 environment and insulating compound (Cl.2.10.10), Tests for semiconductor devices and for cemented joints(Cl.2.10.11), Enclosed and sealed parts(Cl.2.10.12), Ac power supply cord(Cl.3.2.5.1), High pressure lamps (Cl.4.2.9), Radiation (Cl.4.3.13), Ionizing radiation (Cl.4.3.13.2), Effect of UV radiation on materials (Cl.4.3.13. & Annex Y), Human exposure to UV radiation (Cl.4.3.13.4), Laser including LED (Cl.4.3.13.5), Light emitting diodes (LED's) (Cl.4.3.13.5.2), Materials for air filter assemblies (4.7.3.5), Materials used in high voltage components (4.7.3.6) Electromechanical components (Cl. 5.3.5), Unattended Equipments (Cl.5.3.8) Insulating winding wires (c.2.10.5.2 & Annex U), Evaluation of IC current limiters (Annex CC) |
| 13213 |
BIS, Eastern Regional Laboratory (ERL)
| None
| IS 17111 (2025) |
HEAT-TREATABLE STEELS, ALLOY STEELS AND FREE-CUTTING STEELS - BALL AND ROLLER BEARING STEELS ( First Revision ) |
- |
- View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Clause-6.3.1 (Heat-treatment condition) |
- |
|
|
|
| Clause-7.2, Table 3 (C) |
- |
|
|
|
| Clause-7.2, Table 3 (Si) |
- |
|
|
|
| Clause-7.2, Table 3 (Mn) |
- |
|
|
|
| Clause-7.2, Table 3 (S) |
- |
|
|
|
| Clause-7.2, Table 3 (P) |
- |
|
|
|
| Clause-7.2, Table 3 (Ni) |
- |
|
|
|
| Clause-7.2, Table 3 (Cr) |
- |
|
|
|
| Clause-7.2, Table 3 (Mo) |
- |
|
|
|
| Clause -7.2, Table-4 (Al) |
- |
|
|
|
| Clause -7.2, Table-4 (Cu) |
- |
|
|
|
| Clause-6.3.1 (Heat-treatment condition) |
- |
|
|
|
| Clause-7.2, Table 3 (W) |
- |
|
|
|
| Clause-7.2, Table 3 (V) |
- |
|
|
|
|
- |
- Except Ca, O |
| 13214 |
BIS, Eastern Regional Laboratory (ERL)
| None
| IS 410 (1977) |
Specification for cold rolled brass sheet, strip and foil (Third Revision) |
- |
1500/- View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 6.1 Table-1 (Cu) |
- |
|
|
|
| 6.1 Table-1 (Pb) |
- |
|
|
|
| 6.1 Table-1 (Fe) |
- |
|
|
|
| 6.1 Table-1 (Zn) |
- |
|
|
|
| 4.0 (Freedom from defects) |
- |
|
|
|
| 7.1.1 (Tensile Test) |
- |
|
|
|
| Table-2 (Vickers Hardness) |
- |
|
|
|
| Table-2 (Transverse Bend) |
- |
|
|
|
| Table-2 (Longitudinal Bend) |
- |
|
|
|
| Table-2 (Thickness) |
- |
|
|
|
| 7.1.5 (Grain Size - IS 410) |
- |
|
|
|
| 6.1 Table-1 (Total impurities including iron) |
- |
|
|
|
|
- |
- - |
| 13215 |
BIS, Eastern Regional Laboratory (ERL)
| None
| IS 4882 (1979) |
Specification for low carbon steel wire for rivets for use in bearing industry (First Revision) |
For all size |
- View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4.1,4.1.1,5.1 (Carbon- Relevant parts of IS 228 or any other established instrumental /Chemical method) |
- |
|
|
|
| 4.1,4.1.1,5.1 (Manganese- Relevant parts of IS 228 or any other established instrumental /Chemical method) |
- |
|
|
|
| 4.1,4.1.1,5.1 (Silicon- Relevant parts of IS 228 or any other established instrumental /Chemical method) |
- |
|
|
|
| 4.1,4.1.1,5.1 (Sulphur- Relevant parts of IS 228 or any other established instrumental /Chemical method) |
- |
|
|
|
| 4.1,4.1.1,5.1 (Phosphorus- Relevant parts of IS 228 or any other established instrumental /Chemical method) |
- |
|
|
|
| 4.1,4.1.1,5.1 (Nitrogen- Relevant parts of IS 228 or any other established instrumental /Chemical method) |
- |
|
|
|
| 6 (FREEDOM FROM DEFECTS) |
- |
|
|
|
| 7 ( TOLERANCES(Dimension)) |
- |
|
|
|
| 8.1 (Tensile Test ) |
- |
|
|
|
| 8.2.1 ( Cold Upsetting Test ) |
- |
|
|
|
| 8.2.2 ( Wrapping test ) |
- |
|
|
|
| 9 (GRAIN SIZE) |
- |
|
|
|
|
- |
- excluding Grainsize |
| 13216 |
BIS, Southern Regional Laboratory (SRL)
| None
| IS 1489 (Part 1) (2015) |
Portland pozzolana cement - Specification: Part 1 fly Ash Based |
- |
- View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 6 - Table - 1 iv (Loss on ignition - Cl 7.1 of IS 4032:1985) |
- |
|
|
|
| 7 -Table 2- i (Fineness 4031 Part 2) |
- |
|
|
|
| 7 -Table 2- vi (Drying Shrinkage- IS 4031 Part 10) |
- |
|
|
|
| 7 -Table 2- iv- c (Compressive Strength At 672 hrs ± 4 hr - IS 4031 Part 6) |
- |
|
|
|
| 7 -Table 2- iv- b (Compressive Strength At 168 hrs ± 2 hr - IS 4031 Part 6) |
- |
|
|
|
| 7 -Table 2- iv- a (Compressive Strength At 72 hrs ± 1 hr - IS 4031 Part 6) |
- |
|
|
|
| 7 -Table 2-iii- b (Setting Time Final- 4031 Part 5) |
- |
|
|
|
| 7 -Table 2- iii- a (Setting Time Initial- 4031 Part 5) |
- |
|
|
|
| 7 -Table 2- ii- a (Expansion by Le Chatelier- 4031 Part 3) |
- |
|
|
|
| 7 -Table 2- ii- b (Expansion by Autoclave- 4031 Part 3) |
- |
|
|
|
| 6 - Table - 1 vi ( Alkali content as (Na2O + 0.658 K2O) - Cl 4.11 of IS 4032:1985) |
- |
|
|
|
| 6 - Table - 1 v (Chloride content - Cl 4.13 of IS 4032:1985) |
- |
|
|
|
| 6 - Table - 1 iii (Total Sulphur Content calculated as Sulphuric Anhydride (SO3) - Cl 7.3 of IS 4032:1985) |
- |
|
|
|
| 6 - Table - 1 ii (Magnesia - Cl 7.2 of IS 4032:1985) |
- |
|
|
|
| 6 - Table - 1 i (Insoluble residue - Cl 7.4 of IS 4032:1985) |
- |
|
|
|
|
- |
- 8 Kg for Mechanical + Chemical 500 g. Advised Air tight packing with at least 1 month of shelf life.
Excluding Complete other than Transverse Strength (Optional) |
| 13217 |
BLUESKY LAB LLP, GHAZIABAD
| 8170306
| IS 10322 : Part 5 : Sec 1 (2012) |
Luminaires: Part 5 particular requirements: Sec 1 fixed general purpose luminaires (First Revision) |
- |
25000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4(General Test Requireements) |
- |
500 |
|
10% discount offered to BIS |
| 5(Classification of Luminaires') |
- |
500 |
|
10% discount offered to BIS |
| 6.0(Marking) |
- |
1500 |
|
10% discount offered to BIS |
| 7.0(Construction) |
- |
5000 |
|
10% discount offered to BIS |
| 8.0(Creepage Distance and Clearances) |
- |
1000 |
|
10% discount offered to BIS |
| 9.0(Provision for earthing) |
- |
2000 |
|
10% discount offered to BIS |
| 10.0(Terminals) |
- |
2000 |
|
10% discount offered to BIS |
| 11.0(External & Internal Wiring) |
- |
2000 |
|
10% discount offered to BIS |
| 12.0(Protection against electric shock) |
- |
1500 |
|
10% discount offered to BIS |
| 13.0(Endurance Tests and Thermal Tests) |
- |
5000 |
|
10% discount offered to BIS |
| 14.0(Resistance to Dust & Moisture) |
- |
5000 |
|
10% discount offered to BIS |
| 15.0(Insulation Resistance and Electric Strength) |
- |
2000 |
|
10% discount offered to BIS |
| 16.0(Resistance to Heat , fire and tracking) |
- |
1200 |
|
10% discount offered to BIS |
| 17.0(Photometric Test) |
- |
10000 |
|
10% discount offered to BIS |
|
22 May, 2028 |
- Linings and Sleeves (Cl. 4.9), UV Radiation (Cl. 4.24 & annex P) Cl. 4.14 Suspensions and adjusting Devices, Electromechanical Contact System (Cl.4.11.6 of IS 10322-1), Short Circuit Protection (Cl.4.26 of IS 10322-1, IPX8 upto 1.3m Luminaries size restricted to 1000 mm, Torque upto 6 Nm for Cl. 4.12.1 of IS
10322(Pt 1): 2014 IPX8 upto 1.3m |
| 13218 |
BIS, Eastern Regional Laboratory (ERL)
| None
| IS 617 (1994) |
Cast aluminium and its alloys - Ingots and castings for general engineering purposes - Specification (Third Revision) |
For all grade |
- View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 6, Table 2. (MECHANICAL PROPERTIES OF CASTINGS) |
- |
|
|
|
| 6.2 (Hardness) |
- |
|
|
|
| 9 (TOLERANCES ON DIMENSIONS OF CASTINGS) |
- |
|
|
|
| 5, Table 1. (Chemical Composition) |
- |
|
|
|
| Table-1, Clause - 5.1 (Copper) |
- |
|
|
|
| Table-1, Clause - 5.1 (Iron) |
- |
|
|
|
| Table-1, Clause - 5.1 (Magnesium) |
- |
|
|
|
| Table-1, Clause - 5.1 (Manganese) |
- |
|
|
|
| Table-1, Clause - 5.1 (Silicon) |
- |
|
|
|
| Table-1, Clause - 5.1 (Nickel) |
- |
|
|
|
| Table-1, Clause - 5.1 (Zinc) |
- |
|
|
|
| Table-1, Clause - 5.1 (Titanium) |
- |
|
|
|
| Table-1, Clause - 5.1 (Lead) |
- |
|
|
|
| Cl. 5 (Chromium) |
- |
|
|
|
|
- |
- Except Cl.5.1 Al, Sn, Pressure test
Prepared piece for tensile test and hardness test required. |
| 13219 |
BIS, Eastern Regional Laboratory (ERL)
| None
| IS 5312 : Part 1 (2004) |
Swing Check Type Reflux (Non-Return] Valves for Water Works Purposes - Part 1 : Single-Door Pattern |
Size upto 250 mm |
Rs 5700/- View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 6.2 (Manufacture Dimensions Table 2 ) |
- |
|
|
|
| 4 (Nominal Sizes) |
- |
|
|
|
| 6.5 (Manufacture ) |
- |
|
|
|
| 6.4 (Manufacture ) |
- |
|
|
|
| 6.6 (Manufacture ) |
- |
|
|
|
| 6.7 (Manufacture ) |
- |
|
|
|
| 6.8 (Manufacture ) |
- |
|
|
|
| 6.9 (Manufacture ) |
- |
|
|
|
| 6.10 (Manufacture ) |
- |
|
|
|
|
- |
- Except Al , Sb, Tin,Other Elements, (cl8.2 ) hydrostatic body test, (cl 8.3) hydrostatic seat test |
| 13220 |
BIS, Eastern Regional Laboratory (ERL)
| None
| IS 1879 (2010) |
Malleable cast iron pipe fittings - Specification (Third Revision) |
- |
Rs.7800.00 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 5.1.1 (Type of Fittings - IS 1879) |
- |
|
|
|
| 5.1.2 (Size designation - IS 1879) |
- |
|
|
|
| 5.1.2.1 (Equal fitting - IS 1879) |
- |
|
|
|
| 5.1.2.2 (Unequal fitting -IS 1879) |
- |
|
|
|
| 5.1.3 (Right and Left hand thread - IS 1879) |
- |
|
|
|
| 5.1.1 (Code Number -IS 1879) |
- |
|
|
|
| 6.1 (Tensile Strength - IS 14329) |
- |
|
|
|
| 6.1 (Elongation - Is 14329) |
- |
|
|
|
| 7.2- Table 2 (Wall thickness of fittings - IS 1879) |
- |
|
|
|
| 7.5 - Table 2 (Projection of Rainforcement - IS 1879) |
- |
|
|
|
| 7.5 - Table 3 (Width of Rainforcement - IS 1879) |
- |
|
|
|
| 7.1 - Table 4 to Table 27 (a - IS 1879) |
- |
|
|
|
| 7.1 - Table 4 to Table 27 (b - IS 1879) |
- |
|
|
|
| 7.1 - Table 4 to Table 27 (c- IS 1879) |
- |
|
|
|
| 7.1 - Table 4 to Table 27 (d- IS 1879) |
- |
|
|
|
| 7.1 - Table 28 (d -IS 1879) |
- |
|
|
|
| 7.1 - Table 28 (D - IS 1879) |
- |
|
|
|
| 9 (Freedom from defects
) |
- |
|
|
|
| 10.i) (Mass of Galvanized coating) |
- |
|
|
|
| 10.ii) (Uniformity of Galvanized coating-IS 2633) |
- |
|
|
|
| 10.iii) (Adhesion of Galvanized coating IS 2629) |
- |
|
|
|
| 10.iv) (Freedom from defects IS 4759) |
- |
|
|
|
|
- |
- Except Chemical composition as per mutual agreement between purchaser and manufacturer, Cl 7 Threads, Cl 11 Pressure Test, 12 Compression test. Sample req- 3 nos. fittings, Black fittings for compression test, Tensile Test bars, 3 nos. fittings for galvanizing tests |
| 13221 |
BIS, Central Laboratory (CL)
| None
| IS 6956 (2001) |
Cover paper - Specification (First Revision) |
- |
4650 View breakup
"1. for cover paper which are white in colour : 16x300 = Rs.4800.00, 2. for cover paper which are not white in colour : 15x300 = Rs.4500.00
3. test charges for special requirements (for ECO mark) : 6x300 = Rs.1800.00"
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4.1 (REQUIREMENTS-General) |
- |
|
|
|
| 4.3 (Grarnmage-As per 6 of IS 1060 (Part 1)-Further a mean of 10 test results shall not
vary from nominal grarnmage by more than ±4 percent.) |
- |
|
|
|
| 4.3 (Grarnmage-As per 6 of IS 1060 (Part 1)- no single test result shall vary by more than *6 percent from nominal) |
- |
|
|
|
| 4.2,Table1 (One minute Cobb test (Test method Column 4 and 5 of table1)) |
- |
|
|
|
| 4.2,Table1 (Smoothness (Bendtsen)-(Test method Column 4 and 5 of table1)) |
- |
|
|
|
| 4.2,Table1 (Burst Index-(Test method Column 4 and 5 of table1)) |
- |
|
|
|
| 4.2,Table1 (Ph(Test method Column 4 and 5 of table1)) |
- |
|
|
|
| 4.2,Table1 (Folding endurance-MD-(Test method Column 4 and 5 of table1)) |
- |
|
|
|
| 4.2,Table1 (Wax pick-(Test method Column 4 and 5 of table1)) |
- |
|
|
|
| 4.2,Table1 (Folding endurance-CD-(Test method Column 4 and 5 of table1)) |
- |
|
|
|
| 4.2,Table1 (Brightness(For white paper only) -(Test method Column 4 and 5 of table1)) |
- |
|
|
|
| 4.2,Table1 (Opacity, (Test method Column 4 and 5 of table1)) |
- |
|
|
|
| 4.2,Table1 (Bending stiffness index,-CD-(Test method Column 4 and 5 of table1)) |
- |
|
|
|
| 4.2,Table1 (Bending stiffness index,-MD-(Test method Column 4 and 5 of table1)) |
- |
|
|
|
|
- |
- Test facility is not available for mentioned exclusiosn parameters;
EXCLUDING Brightness, Bending stiffness; |
| 13222 |
BIS, Central Laboratory (CL)
| None
| IS 2566 (1993) |
Textiles – B-twill jute bags for packing foodgrains – Specification (third revision) |
- |
4800 View breakup
Rs 4800/-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl.5.2 & Table 2.
IS 2969 ( The bales containing the bags shall conform to the requirements as laid down in Table 2.
vi) Oil content on dry deoiled
material basis, percent, Max) |
- |
|
|
|
|
- |
- - |
| 13223 |
Softlines and Electrical Safety Testing Laboratory TUV Rheinland India Pvt Ltd., Gurgaon (8167106)
| 8167106
| IS 9873 : Part 9 (2017) |
Safety of Toys Part 9 Certain Phthalates Esters in Toys and Children's Products |
- |
6000 View breakup
Rs.6000/- (10% discount to BIS)
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 3.0(Vinyl in any part of the toy or childcare article that can be placed in mouth of a child under 4 years of age - a) Di-iso-Nonyl Phthalate (DINP), b) Di-iso-Decyl Phthalate (DIDP), c) Di-n-Octyl Phthalate (DNOP) - IS 9873 Part 6) |
- |
6000 |
|
- |
| 3.0(Vinyl in toys or childcare articles - a) Bis-(2-ethlyhexyl) Phthalates (DEHP), b) Di-Butyl phthalate (DBP), c) Benzyl butyl Phthalate (BBP) - IS 9873 Part 6) |
- |
6000 |
|
- |
|
19 Jan, 2027 |
- - |
| 13224 |
Softlines and Electrical Safety Testing Laboratory TUV Rheinland India Pvt Ltd., Gurgaon (8167106)
| 8167106
| IS 9873 : Part 3 (2020) |
Safety of Toys Part 3 Migration of Certain Elements ( Third Revision ) |
- |
4500 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4.1 - Table 1(Selenium (Se) - Cl 7,8,9 of IS 9873-3 : 2017 and ISO 8124-3 : 2010) |
- |
950 |
|
- |
| 4.1 - Table 1(Mercury (Hg) - Cl 7,8,9 of IS 9873-3 : 2017 and ISO 8124-3 : 2010) |
- |
950 |
|
- |
| 4.1 - Table 1(Arsenic (As) - Cl 7,8,9 of IS 9873-3 : 2017 and ISO 8124-3 : 2010) |
- |
950 |
|
- |
| 4.1 - Table 1(Cadmium (Cd) - Cl 7,8,9 of IS 9873-3 : 2017 and ISO 8124-3 : 2010) |
- |
950 |
|
- |
| 4.1 - Table 1(Lead (Pb) - Cl 7,8,9 of IS 9873-3 : 2017 and ISO 8124-3 : 2010) |
- |
950 |
|
- |
| 4.1 - Table 1(Antimony (Sb) - Cl 7,8,9 of IS 9873-3 : 2017 and ISO 8124-3 : 2010) |
- |
950 |
|
- |
| 4.1 - Table 1(Barium (Ba) - Cl 7,8,9 of IS 9873-3 : 2017 and ISO 8124-3 : 2010) |
- |
950 |
|
- |
| 4.1 - Table 1(Chromium (Cr) - Cl 7,8,9 of IS 9873-3 : 2017 and ISO 8124-3 : 2010) |
- |
950 |
|
- |
|
19 Jan, 2027 |
- - |
| 13225 |
BIS, Central Laboratory (CL)
| None
| IS 5604 (1984) |
Specification for hand - Operated universal gearless pulling and lifting machines (First Revision) |
- |
- View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4 (Capacity) |
- |
|
|
|
| 5.3 (Construction and Workmanship
Casing) |
- |
|
|
|
| 5.4 (Construction and Workmanship
Bearings) |
- |
|
|
|
| 5.4.1 (Ball and Roller Bearings) |
- |
|
|
|
| 5.4.2 (Plain Bearings) |
- |
|
|
|
| 5.5 (Wire Ropes) |
- |
|
|
|
| 5.6 (Heat Treatment) |
- |
|
|
|
| 5.7 (Construction and Workmanship
Bearings) |
- |
|
|
|
| 5.8 (Weight) |
- |
|
|
|
| 7.1 (Operation) |
- |
|
|
|
| 7.2 (Operation) |
- |
|
|
|
| 7.3 (Operation) |
- |
|
|
|
| 7.4 (Operation
Back Slippage) |
- |
|
|
|
| 8 (Effort) |
- |
|
|
|
| 9.1 (Proof Loading) |
- |
|
|
|
| 9.2 (Operational Test) |
- |
|
|
|
| 9.3 (Break Load Testing ) |
- |
|
|
|
| 9.4 (Examination) |
- |
|
|
|
| 11.1 (Marking) |
- |
|
|
|
| Clause -3, 3.1 (Steel bars, Plates and sections) |
- |
|
|
|
| Clause -3, 3.1 (Steel Forgings) |
- |
|
|
|
| Clause -3, 3.1 (Aluminium Alloy) |
- |
|
|
|
| Clause -3, 3.1 (Coil Springs) |
- |
|
|
|
| Clause -3, 3.1 (Hooks) |
- |
|
|
|
| Clause -3, 3.1 (Wire Ropes) |
- |
|
|
|
|
- |
- EXCLUDING -; i] cl 7.4 back slippage, ii] cl 9.2 operational test |
| 13226 |
BIS, Central Laboratory (CL)
| None
| IS 1943 (1995) |
Textiles – A-twill jute bags (second revision) |
- |
Rs4100/- View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4.1,5.1,Table 1 (Moisture Regain, Percent-IS 9113) |
- |
|
|
|
| 4.1,5.1,Table 1 (Oil content, Percent-IS 2969) |
- |
|
|
|
|
- |
- - |
| 13227 |
BIS, Central Laboratory (CL)
| None
| IS 3992 (1982) |
Specification for trays, kidney (First Revision) |
- |
Rs.1275/- and material testing charges as per relevant View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 3.1&3.2 (C - IS 228) |
- |
|
|
|
| 3.1&3.2 (S - IS 228) |
- |
|
|
|
| 3.1&3.2 (P - IS 228) |
- |
|
|
|
| 3.1&3.2 (Mn - IS 228) |
- |
|
|
|
| 3.1&3.2 (Si - IS 228) |
- |
|
|
|
| 3.1&3.2 (Cr - IS 228) |
- |
|
|
|
| 3.1&3.2 (Ni - IS 228) |
- |
|
|
|
| 4.1 (Shape) |
- |
|
|
|
| 4.2, Table-1,1 (Length -A - IS 3992) |
- |
|
|
|
| 4.2, Table-1,2 (Width -B - IS 3992) |
- |
|
|
|
| 4.2, Table-1,3 (Height -C - IS 3992) |
- |
|
|
|
| 4.2, Table-1,7 (Minimum Thickness of material) |
- |
|
|
|
| 5.0 &5.1 (Workmanship and finish of stainless steel Trays) |
- |
|
|
|
| 5.0 & 5.2 (Workmanship and finish of Enamelled Iron Trays) |
- |
|
|
|
|
- |
- - |
| 13228 |
BIS, Central Laboratory (CL)
| None
| IS 2932 (2013) |
Enamel, synthetic, exterior: (a) Undercoating (b) Finishing - Specification (Fourth Revision) |
- |
- View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 6.3 (Freedom from Coarse Particles) |
- |
|
|
|
| 6.4 (Skin Formation) |
- |
|
|
|
| 6.5 (Thinning Properties) |
- |
|
|
|
| 6.6 (Application Properties) |
- |
|
|
|
| 6.8 (Lead Restriction) |
- |
|
|
|
| 6.9 Table 2 (1) a. Consistency ( Undercoating and Finishing ) ) |
- |
|
|
|
| 6.9 Table 2 (1) b. Viscosity by ford 80-120 s ) |
- |
|
|
|
| 6.9 Table 2 ( 2) Mass, ( Under coating ) ) |
- |
|
|
|
| 6.9 Table 2 ( 2) Mass, (Finishing ) ) |
- |
|
|
|
| 6.9 Table 2 (3) Drying time, a) Surface dry, ( Under coating ) ) |
- |
|
|
|
| 6.9 Table 2 (3) Drying time, a) Surface dry, ( Finishing ) ) |
- |
|
|
|
| 6.9 Table 2 (b) Hard dry ( Under coating ) ) |
- |
|
|
|
| 6.9 Table 2 (b) Hard dry, (Finishing ) ) |
- |
|
|
|
| 6.9 Table 2 (c) Tack free ( Under coating (Finishing ) ) |
- |
|
|
|
| 6.9 Table 2 (4) a) Finish (Under coating ) ) |
- |
|
|
|
| 6.9 Table 2 (4) a) Finish (Finishing) ) |
- |
|
|
|
| 6.9 Table 2 (b) ) Gloss 60º (Under coating ) ) |
- |
|
|
|
| 6.9 Table 2 (b) ) Gloss 60º (Finishing) ) |
- |
|
|
|
| 6.9 Table 2 (5) Fineness of grind,(Under coating )) |
- |
|
|
|
| 6.9 Table 2 (4) a) Finish (Finishing) ) |
- |
|
|
|
| 6.9 Table 2 (6) Colour , (Finishing)) |
- |
|
|
|
| 6.9 Table 2 (7) Flexibility and adhesion: a) Scratch hardness No such scratch as to show the bare metal after Clause 3 of —
(Load 1 000 g) ( Under coating & Finishing ) ) |
- |
|
|
|
| 6.9 Table 2 (b) Bend test
(with 6.25 mm 48 h of air
in type 1 apparatus) ( Under coating & Finishing ) ) |
- |
|
|
|
| 6.9 Table 2 (8) Flash point ( Under coating & Finishing ) ) |
- |
|
|
|
| 6.9 Table 2 (9) Composition:b) Phthalic anhydride content of non-volatile vehicle ( Under coating & Finishing )) |
- |
|
|
|
| 6.9 Table 2 (11) Resistance to alkali ( Under coating & Finishing )) |
- |
|
|
|
| 6.9 Table 2 (12) Accelerated storage stability test ( Under coating & Finishing )) |
- |
|
|
|
| 6.9 Table 2 (13) Keeping properties ( Under coating & Finishing )) |
- |
|
|
|
| 6.9 Table 2 (14) Wet opacity ( Under coating & Finishing )) |
- |
|
|
|
|
- |
- Weatherometer for durability, approved sample for resistance to acid and alkali, test facility for volume solids test is required;
EXCLUDING Durability, Volume solids, Resistance to acid and alkali; |
| 13229 |
BIS, Central Laboratory (CL)
| None
| IS 10350 (2020) |
Powder Hair Dyes — Specification ( Third Revision ) |
- |
3,840 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4.6 Table 2 () Calculated active matter (as PPD) in the solution after recommended dilution with water/diluent, type 1) |
- |
|
|
|
| 4.5 Table 1 (Arsenic (as As2 O3 ), for all types) |
- |
|
|
|
| 4.6 Table 2 () Calculated active matter (as PPD) in the solution after recommended dilution with water/diluent, type 1) |
- |
|
|
|
| 4.6 Table 2 () Calculated active matter (as PPD) in the solution after recommended dilution with water/diluent, type 1) |
- |
|
|
|
| 4.5 Table 2 (pH, Type 3) |
- |
|
|
|
| 4.5 Table 1 (pH, type 1 and 2) |
- |
|
|
|
| 4.5 Table 1 (Active matter as PPD content, Type 1) |
- |
|
|
|
| 4.1 (description) |
- |
|
|
|
| 4.6 Table 2 () Calculated active matter (as PPD) in the solution after recommended dilution with water/diluent, type 1) |
- |
|
|
|
| 4.5 Table 1 (Arsenic (as As2 O3 ), for all types) |
- |
|
|
|
| 4.6 Table 2 () Calculated active matter (as PPD) in the solution after recommended dilution with water/diluent, type 1) |
- |
|
|
|
| 4.5 Table 1 (pH, type 1 and 2) |
- |
|
|
|
| 4.5 Table 1 (Heavy metals (as Pb), for all types) |
- |
|
|
|
| 4.5 Table 1 (Active matter as PPD content, Type 1) |
- |
|
|
|
| 4.1 (description) |
- |
|
|
|
| 4.5 Table 1 (Dye ingredients, type 3 only) |
- |
|
|
|
|
- |
- - |
| 13230 |
Delhi Analytical Research Laboratory
| 8169106
| IS 13488 (2008) |
Irrigation equipment - Emitting pipe systems - Specification (First Revision) |
12 to 25 mm |
12400 View breakup
Rs.12400/-(10% discount to BIS)
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 6.2.2(Fittings) |
- |
500 |
|
10% discount to BIS |
| 8.1.3(Uniformity of Emission Rate for Regulated Emitting Pipes) |
- |
800 |
|
10% discount to BIS |
| 8.1.2(Uniformity of Emission Rate for Unregulated Emitting Pipes) |
- |
800 |
|
10% discount to BIS |
| 8.2.2(Regulated Emitting Pipes) |
- |
800 |
|
10% discount to BIS |
| 8.3.1(Wall Thickness ofEmitting Pipe) |
- |
200 |
|
10% discount to BIS |
| 8.3.2(Inside Diameter ofEmitting Pipe) |
- |
300 |
|
10% discount to BIS |
| 8.3.3(Flow Paths in Emitting Unit) |
- |
300 |
|
10% discount to BIS |
| 8.3.4(Spacing ofEmitter Units) |
- |
200 |
|
10% discount to BIS |
| 8.5(Resistance to Tension at Elevated Temperature) |
- |
1500 |
|
10% discount to BIS |
| 8.6(Resistance to Pull Out of Joints Between Fitting and Emitting
IS 13479) |
- |
1500 |
|
10% discount to BIS |
| 8.7.1(Resistance of PE Emitting Pipe to
Environmental Stress Cracking -Acceptance Test
Annex D of IS 12786) |
- |
1500 |
|
10% discount to BIS |
| 8.2(Emission Rate of Emitting Unit as a Function of Inlet Pressure) |
- |
1500 |
|
10% discount to BIS |
| 8.4.1(Resistance to Hydrostatic Pressure at Ambient Temperature) |
- |
1500 |
|
10% discount to BIS |
| 8.8(Determination of Emitting Unit Exponent) |
- |
1500 |
|
10% discount to BIS |
| 5.1.2 (Ref. Cl 4.1.a of IS 12786 : 1989)(Potyethylene - higher olefins constituent ) |
- |
700 |
|
10% discount to BIS |
| 5.1.2 (Ref. Cl 4.1.b of IS 12786 : 1989)(Potyethylene - anti-oxidant) |
- |
1500 |
|
10% discount to BIS |
| 5.1.2 (Ref. Cl 4.1.c.i of IS 12786 : 1989)(Density) |
- |
500 |
|
10% discount to BIS |
| 5.1.2 (Ref. Cl 4.1.c.ii of IS 12786 : 1989)(Toluene extract - Annex A of IS 12786:1989) |
- |
700 |
|
10% discount to BIS |
| 5.1.2 (Ref. Cl 4.1.c.iii of IS 12786 : 1989)(Volatile matter - Annex B of IS 12786:1989) |
- |
1000 |
|
10% discount to BIS |
| 5.1.2 (Ref. Cl 4.1.c & 4.2.a of IS 12786 : 1989)(Carbon Black content - IS 2530 : 1963) |
- |
1000 |
|
10% discount to BIS |
| 5.1.2 (Ref. Cl 4.2.b of IS 12786 : 1989)(The dispersion of Carbon Black content shall be satisfactory - IS 2530 : 1963) |
- |
800 |
|
10% discount to BIS |
| 8.4.2(Resistance to Hydrostatic Pressure at Elevated Temperature) |
- |
1500 |
|
10% discount to BIS |
| 8.7.2(Resistance of PE Emitting Pipe to
Environmental Stress Cracking - Type Test
Annex D of IS 12786) |
- |
1500 |
|
10% discount to BIS |
|
- |
- - |