| 13951 |
DELHI TEST HOUSE, Azadhpur
| 8131406
| IS 7834 : Part 1 (1987) |
injection moulded PVC socket fittings with solvent cement joints for water supplies: Part 1 General requirements |
- |
5200 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl.4(Minimum Thickness) |
- |
250 |
|
For BIS samples 1.5 times of BIS testing charges |
| Cl. 5.1.1, 5.1.2, Table 1, Fig 1(Minimum Socket Length) |
- |
200 |
|
For BIS samples 1.5 times of BIS testing charges |
| Cl. 5.1.1, 5.1.2, Table 1, Fig 1(Mean Socket Internal Diameter at Mid-Point of Socket Length) |
- |
200 |
|
For BIS samples 1.5 times of BIS testing charges |
| Cl. 5.1.1, 5.1.2, Table 1, Fig 1(Out-of-roundness tolerances of socket inside diameter) |
- |
200 |
|
For BIS samples 1.5 times of BIS testing charges |
| Cl. 6.1(Stress Relief Test- Appendix A) |
- |
750 |
|
For BIS samples 1.5 times of BIS testing charges |
| Cl. 6.2(Opacity- Appendix B) |
- |
750 |
|
For BIS samples 1.5 times of BIS testing charges |
| Cl. 6.3(Effect on Water[(Lead ( first extraction )]- Appendix C) |
- |
250 |
|
For BIS samples 1.5 times of BIS testing charges |
| Cl. 6.3(Effect on Water[(Lead ( third extraction )]- Appendix C) |
- |
250 |
|
For BIS samples 1.5 times of BIS testing charges |
| Cl. 6.3(Effect on Water [Dialkyl tin C4, and higher homologues, measured as tin ( third extraction )]- Appendix C) |
- |
500 |
|
For BIS samples 1.5 times of BIS testing charges |
| Cl. 6.3(Effect on Water [Other toxic substances ( third extraction )]- Appendix C) |
- |
1000 |
|
For BIS samples 1.5 times of BIS testing charges |
| Cl. 6.4(Short-Term Hydraulic Test- Appendix D) |
- |
1200 |
|
For BIS samples 1.5 times of BIS testing charges |
|
17 Jun, 2027 |
- - |
| 13952 |
CIPET, Jaipur
| 8122834
| IS 7834 : Part 1 (1987) |
injection moulded PVC socket fittings with solvent cement joints for water supplies: Part 1 General requirements |
All Size |
5625 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl.4(Minimum Thickness) |
- |
250 |
|
- |
| Cl. 5.1.1, 5.1.2, Table 1, Fig 1(Minimum Socket Length) |
- |
250 |
|
- |
| Cl. 5.1.1, 5.1.2, Table 1, Fig 1(Mean Socket Internal Diameter at Mid-Point of Socket Length) |
- |
0 |
|
- |
| Cl. 5.1.1, 5.1.2, Table 1, Fig 1(Out-of-roundness tolerances of socket inside diameter) |
- |
0 |
|
- |
| Cl. 6.1(Stress Relief Test- Appendix A) |
- |
700 |
|
- |
| Cl. 6.2(Opacity- Appendix B) |
- |
575 |
|
- |
| Cl. 6.3(Effect on Water[(Lead ( first extraction )]- Appendix C) |
- |
3000 |
|
- |
| Cl. 6.3(Effect on Water[(Lead ( third extraction )]- Appendix C) |
- |
0 |
|
- |
| Cl. 6.3(Effect on Water [Dialkyl tin C4, and higher homologues, measured as tin ( third extraction )]- Appendix C) |
- |
0 |
|
- |
| Cl. 6.3(Effect on Water [Other toxic substances ( third extraction )]- Appendix C) |
- |
0 |
|
- |
| Cl. 6.4(Short-Term Hydraulic Test- Appendix D) |
- |
850 |
|
- |
|
21 Feb, 2029 |
- - |
| 13953 |
CIPET, Jaipur
| 8122834
| IS 7834 : Part 3 (1987) |
injection moulded PVC socket fittings with solvent cement joints for water supplies: Part 3 Specific requirements for 90 degree elbows |
All |
5625 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| cl 2.2.2(Dimensions) |
- |
500 |
|
- |
| Cl. 2.1 (Ref. Cl. 6.3 of IS 7834 (part 1) : 1987(Effect on water - Lead (first extraction) - Appendix C ) |
- |
3000 |
|
- |
| Cl. 2.1 (Ref. Cl. 6.3 of IS 7834 (part 1) : 1987(Effect on water - Lead (third extraction) - Appendix C) |
- |
0 |
|
- |
| Cl. 2.1 (Ref. Cl. 6.3 of IS 7834 (part 1) : 1987(Effect on water - Dialkyl tin C4 and higher homologues measured as tin (third extraction) - Appendix C) |
- |
0 |
|
- |
| Cl. 2.1 (Ref. Cl. 6.3 of IS 7834 (part 1) : 1987(Effect on water - Other toxic substances (third extraction) - Appendix C) |
- |
0 |
|
- |
|
21 Feb, 2029 |
- - |
| 13954 |
CIPET, Jaipur
| 8122834
| IS 7834 : Part 6 (1987) |
injection moulded PVC socket fittings with solvent cement joints for water supplies: Part 6 Specific requirements for sockets |
All |
5625 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 2.1(General) |
- |
4100 |
|
VCM content(3000.00)+K value(1100.00) |
| 2.2(Manufacture) |
- |
300 |
|
- |
| 2.2.2, Table 1(Size) |
- |
250 |
|
- |
| 2.2.2, Table 1(Socket Laying
Length) |
- |
250 |
|
- |
| 2.2.3( inside diameter of the socket) |
- |
0 |
|
- |
| 2.2.3(Socket length) |
- |
0 |
|
- |
|
21 Feb, 2029 |
- - |
| 13955 |
CIPET, Jaipur
| 8122834
| IS 7834 : Part 8 (1987) |
injection moulded PVC socket fittings with solvent cement joints for water supplies: Part 8 Specific requirements for caps |
All |
5625 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 2.1(General) |
- |
4100 |
|
VCM content(3000.00) + K value(1100.00) |
| 2.2(Manufacture) |
- |
300 |
|
- |
| 2.2.2(diameter of the socket of cap) |
- |
500 |
|
- |
|
21 Feb, 2029 |
- - |
| 13956 |
CIPET, Jaipur
| 8122834
| IS 7834 : Part 2 (1987) |
injection moulded PVC socket fittings with solvent cement joints for water supplies: Part 2 Specific requirements for 45 degrees elbows |
All Size |
5625 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 2.1(General) |
- |
4100 |
|
VCM content(3000.00)+ K value(1100.00) |
| 2.2(Manufacture) |
- |
300 |
|
- |
| 2.2.2, Table 1(Size) |
- |
250 |
|
- |
| 2.2.2, Table 1(45 ÌŠ Elbow Laying
Length) |
- |
250 |
|
- |
| 2.2.3( inside diameter of the socket) |
- |
500 |
|
- |
| 2.2.3(socket length) |
- |
0 |
|
- |
|
21 Feb, 2029 |
- - |
| 13957 |
CIPET, Jaipur
| 8122834
| IS 7834 : Part 4 (1987) |
injection moulded PVC socket fittings with solvent cement joints for water supplies: Part 4 Specific requirements for 90 degree tees |
All size |
5625 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 2.1(General) |
- |
4100 |
|
VCM content(3000.00)+ K value(1100.00) |
| 2.2(Manufacture) |
- |
300 |
|
- |
| 2.2.2, Table 1(90 ÌŠ Elbow Laying
Length) |
- |
250 |
|
- |
| 2.2.3( inside diameter of the socket) |
- |
500 |
|
- |
| 2.2.3(Socket length) |
- |
0 |
|
- |
|
21 Feb, 2029 |
- - |
| 13958 |
CIPET, Jaipur
| 8122834
| IS 7834 : Part 5 (1987) |
Injection Moulded PVC Socket Fittings With Solvent Cement Joints for Water Supplies - Part 5 : Specific Requirements for 45 degree Tees |
All size |
5625 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 2.1(General) |
- |
4100 |
|
VCM content(3000.00)+K value(1100.00) |
| 2.2(Manufacture) |
- |
250 |
|
- |
| 2.2.2, Table 1(Size) |
- |
500 |
|
- |
| 2.2.2, Table 1(45 ÌŠ Tees Laying
Length, Z) |
- |
0 |
|
- |
| 2.2.3( inside diameter of the socket) |
- |
500 |
|
- |
| 2.2.3(Socket length) |
- |
0 |
|
- |
|
21 Feb, 2029 |
- - |
| 13959 |
CIPET, Jaipur
| 8122834
| IS 7834 : Part 7 (1987) |
injection moulded PVC socket fittings with solvent cement joints for water supplies: Part 7 Specific requirements for unions |
All size |
5625 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 2.1(General) |
- |
4100 |
|
VCM content(3000.00)+K value(1100.00) |
| 2.2(Manufacture) |
- |
250 |
|
- |
| 2.2.2, Table 1(Size) |
- |
500 |
|
- |
| 2.2.2, Table 1(Union Laying
Length) |
- |
0 |
|
- |
| 2.2.3( inside diameter of the socket) |
- |
500 |
|
- |
| 2.2.3(Socket length) |
- |
0 |
|
- |
|
21 Feb, 2029 |
- - |
| 13960 |
Bharat Test House Pvt Ltd 1474 Sonipat Haryana
| 9135626
| IS 10322 : Part 5 : Sec 4 (1987) |
Specification for luminaires: Part 5 particular requirements: Sec 4 portable general purpose luminaires |
Portable General Purpose Luminaires |
42000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 5(Marking) |
- |
500 |
|
5% discount for BIS |
| 6(Construction) |
- |
4500 |
|
5% discount for BIS |
| 7(Creepage Distance
And Clearances) |
- |
1000 |
|
5% discount for BIS |
| 8(Provision for
Earthing) |
- |
1000 |
|
5% discount for BIS |
| 9(Terminals) |
- |
3000 |
|
5% discount for BIS |
| 10(External &
Internal Wiring) |
- |
2000 |
|
5% discount for BIS |
| 11(Protection Against
Electric Shock ) |
- |
1000 |
|
5% discount for BIS |
| 13.3(Mechanical
Strength Test ) |
- |
3000 |
|
5% discount for BIS |
| 13.4(Endurance Test
and Thermal test) |
- |
3000 |
|
5% discount for BIS |
| 13.5(Resistance To
Dust & Moisture) |
- |
3000 |
|
5% discount for BIS |
| 13.6(Insulation Resistance
and Electric Strength) |
- |
3000 |
|
5% discount for BIS |
| 13.7(Resistance to Heat,
Fire & Tracking) |
- |
3000 |
|
5% discount for BIS |
| 13.8(Photometric Test) |
- |
14000 |
|
5% discount for BIS |
|
19 Mar, 2029 |
- - |
| 13961 |
DELHI TEST HOUSE, Azadhpur
| 8131406
| IS 447 (1988) |
Specification for rubber hose for welding (Fourth Revision) |
- |
10000 View breakup
For BIS samples: 1.5 times of BIS testing charges, For others
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl. 3.2 - Table 1(Bore size) |
- |
500 |
|
For BIS samples 1.5 times of BIS testing charges |
| Cl. 3.3 - Table 2(Tensile strength - Lining MPA) |
- |
4000 |
|
For BIS samples 1.5 times of BIS testing charges |
| Cl. 3.4 - Table3(Pressure Tests) |
- |
5000 |
|
For BIS samples 1.5 times of BIS testing charges |
|
17 Jun, 2027 |
- - |
| 13962 |
Bharat Test House Pvt Ltd 1474 Sonipat Haryana
| 9135626
| IS 7098 : Part 1 (1988) |
Specification for crosslinked polyethylene insulated pvc sheathed cables: Part 1 for working voltages up to and including 1100 volts (First Revision) |
- |
28000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 3(CONDUCTOR: MATERIALS) |
- |
0 |
|
- |
| 4(INSULATION : MATERIALS) |
- |
0 |
|
- |
| 5.1(FILLER AND INNER SHEATH) |
- |
0 |
|
- |
| 5.2(FILLER AND INNER SHEATH) |
- |
0 |
|
- |
| 6(ARMOURING) |
- |
0 |
|
- |
| 7(OUTER SHEATH) |
- |
0 |
|
- |
| 8.1(CONDUCTOR: CONSTRUCTION) |
- |
0 |
|
- |
| 8.2(PROTECTIVE BARRIER) |
- |
0 |
|
- |
| 8.3(SIZE OF NEUTRAL CONDUCTOR) |
- |
0 |
|
- |
| 9.1(Insulation Applied by extrusicn) |
- |
0 |
|
- |
| 9.2(Thickness of Insulation - Average) |
- |
1000 |
|
- |
| 9.3(Thickness of Insulation - Minimum) |
- |
1000 |
|
- |
| 9.4(Application of Insulation) |
- |
0 |
|
- |
| 10.1(Core Identification) |
- |
0 |
|
- |
| 10.2(Core Identification- Neutral) |
- |
0 |
|
- |
| 10.3(Core Identification by number ) |
- |
0 |
|
- |
| 10.4(Core Identification by number - Neutral ) |
- |
0 |
|
- |
| 11(LAVING UP OF CORES) |
- |
0 |
|
- |
| 12.1 & 12.2(Inner sheath : Application) |
- |
0 |
|
- |
| 12.3(Thickness of Inner Sheath) |
- |
1000 |
|
- |
| 13.1(Armouring: Application) |
- |
0 |
|
- |
| 13.1.2(Armouring: Coverage ) |
- |
0 |
|
- |
| 13.1.3(Armouring: Direction of Lay ) |
- |
0 |
|
- |
| 13.2(Type of armour ) |
- |
0 |
|
- |
| 13.3(Armouring : Dimensions -Wire Diameter) |
- |
1000 |
|
- |
| 13.3(Armouring : Dimensions -Formed wire ) |
- |
1000 |
|
- |
| 13.4(Armour: Joint) |
- |
0 |
|
- |
| 13.5(Armouring : Resistance Test) |
- |
800 |
|
- |
| 13.6 a)(ARMOURING: Tensile Strength) |
- |
1000 |
|
- |
| 13.6 b)(ARMOURING: Elongation ) |
- |
1000 |
|
- |
| 13.6 c)(ARMOURING: Torsion Test (For round wire ) ) |
- |
750 |
|
- |
| 13.6 d)(ARMOURING: Winding Test(For formed wire)) |
- |
750 |
|
- |
| 13.6 e)(ARMOURING: Uniformity of zinc coating) |
- |
750 |
|
- |
| 13.6 f)(ARMOURING: Mass of zinc coating ) |
- |
750 |
|
- |
| 13.6 g)(ARMOURING: Resistivity) |
- |
800 |
|
- |
| 14.1(Outer Sheath : Application) |
- |
0 |
|
- |
| 14.2(Colour of outer sheath) |
- |
0 |
|
- |
| 14.3(Thickness of outer sheath - AVERAGE) |
- |
1000 |
|
- |
| 14.3(Thickness of outer sheath - minimum) |
- |
1000 |
|
- |
| 15.1 a) i)(Annealing Test ( For copper wire ) ) |
- |
1000 |
|
- |
| 15.1 a) ii)(Tensile test (for aluminium) - Before stranding ) |
- |
1000 |
|
- |
| 15.1 a) ii)(Tensile test (for aluminium) - After stranding ) |
- |
1200 |
|
- |
| 15.1 a) iii)(Wrapping test (for aluminium)) |
- |
1000 |
|
- |
| 15.1 a) iv)(Resistance test - Main conductor) |
- |
1000 |
|
- |
| 15.1 a) iv)(Resistance test - Neutral conductor) |
- |
1000 |
|
- |
| 15.1 d) i) (Phyaical tests for insulation : Tensile Test) |
- |
1000 |
|
- |
| 15.1 d) i) (Phyaical tests for insulation : Elongation) |
- |
1000 |
|
- |
| 15.1 d) ii) (Phyaical tests for insulation - Ageing in air Oven : Tensile Variation ) |
- |
1000 |
|
- |
| 15.1 d) ii) (Phyaical tests for insulation- Ageing in air oven : Elongation Variation ) |
- |
1000 |
|
- |
| 15.1 d) iii) (Phyaical tests for insulation : Hot set ) |
- |
800 |
|
- |
| 15.1 d) iii) (Phyaical tests for insulation : Permanent set ) |
- |
800 |
|
- |
| 15.1 d) iv) (Phyaical tests for insulation : Shrinkage ) |
- |
800 |
|
- |
| 15.1 d) iv) (Phyaical tests for insulation : Shrinkage - Crack observed ) |
- |
800 |
|
- |
| 15.1 d) v) (Insulation: Waterabsorption(gravimetric)) |
- |
800 |
|
- |
| 15.1 e) i) (Physical tests for outer sheath : Tensile stregth) |
- |
1000 |
|
- |
| 15.1 e) i) (Physical tests for outer sheath : Elongation) |
- |
1000 |
|
- |
| 15.1 e) ii) (Physical tests for outer sheath- Ageing in air oven : Tensile stregth ) |
- |
1200 |
|
- |
| 15.1 e) ii) (Physical tests for outer sheath -Ageing in air oven : Elongation ) |
- |
1200 |
|
- |
| 15.1 e) ii) (Physical tests for outer sheath- Ageing in air oven : Tensile stregth Variation ) |
- |
1200 |
|
- |
| 15.1 e) ii) (Physical tests for outer sheath -Ageing in air oven : Elongation Variation ) |
- |
1200 |
|
- |
| 15.1 e) iii) (Sheath: Loss of mass in air oven) |
- |
800 |
|
- |
| 15.1 e) iv) (Phyaical tests for Sheath : Shrinkage ) |
- |
100 |
|
- |
| 15.1 e) iv) (Phyaical tests for Sheath : Shrinkage - Crack observed ) |
- |
1000 |
|
- |
| 15.1 e) v) (Sheath : Hot deformation) |
- |
1100 |
|
- |
| 15.1 e) vi) (Sheath : Heat shock test) |
- |
800 |
|
- |
| 15.1 e) vii) (Sheath : Thermalstability) |
- |
800 |
|
- |
| 15.1 f)(INSULATION RESISTANCE TEST : Volume resistivity ) |
- |
800 |
|
- |
| 16.2(HIGH VOLTAGE TEST ) |
- |
1500 |
|
- |
| 16.3(FLAMMABILITY TEST : Period of Burning ) |
- |
1600 |
|
- |
| 16.3(FLAMMABILITY TEST : Unaffected length ) |
- |
1600 |
|
- |
| 16.9(Oxygen Index Test) |
- |
1100 |
|
- |
| 16.1(Flame Retardance Test on Single Cables) |
- |
1250 |
|
- |
| 16.11(Flame Retardance Test on Bunched Cables) |
- |
1250 |
|
- |
| 16.13(Test for Halogen Acid Gas Evolution) |
- |
1100 |
|
- |
| 16.14(Temperature Index) |
- |
1100 |
|
- |
| 17.1(Manufacturer'. identification) |
- |
0 |
|
- |
| 17.2(cable Indentification ) |
- |
0 |
|
- |
| 17.3(cable Code ) |
- |
0 |
|
- |
|
19 Mar, 2029 |
- - |
| 13963 |
CENTRAL INSTITUTE OF PETROCHEMICALS ENGINEERING AND TECHNOLOGY (CIPET):CSTS-BHOPAL
| 8100534
| IS 8069 (1989) |
High density polyethylene (HDPE) woven sacks for packing pesticides – Specification (second revision) |
- |
- View breakup
Rs.3088/-
(After 25% discount for BIS)
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
No Record Found
|
|
31 Dec, 2026 |
- Included w.e.f. 29.06.2017. |
| 13964 |
CIPET, Jaipur
| 8122834
| IS 12786 (1989) |
Irrigation equipment - Polyethylene pipes for irrigation laterals - Specification |
All |
9725 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 5 and Table 1(DIMENSIONS OF PIPES - outside diameters) |
- |
500 |
|
- |
| 4.1.a (Potyethylene - higher olefins constituent ) |
- |
0 |
|
- |
| 4.1.b(Potyethylene - anti-oxidant) |
- |
0 |
|
- |
| 4.1.c.i (Density) |
- |
500 |
|
- |
| 4.1.c.ii (Toluene extract - Annex A) |
- |
1100 |
|
- |
| 4.1.c.iii (Volatile matter - Annex B ) |
- |
700 |
|
- |
| 4.1.c & 4.2.a (Carbon Black content - IS 2530 : 1963) |
- |
700 |
|
- |
| 4.2.b (The dispersion of Carbon Black content shall be satisfactory - IS 2530 : 1963) |
- |
700 |
|
- |
| 4.3(Addition of not more than 10 percent of the manufactures own rework material produced during the manufacture and works testing of pipe complying with this standard is permitted. No other rework material shall be used) |
- |
0 |
|
- |
| 7.3(Tensile Test) |
- |
1350 |
|
Tensile strength(1100.00)+ Specimen preparation(250.00) |
| 7.3(Elongation at Break) |
- |
1350 |
|
Tensile strength(1100.00)+ Specimen preparation(250.00) |
| 7.4(SusceptibiIity to Environmental Stress
Cracking) |
- |
1200 |
|
- |
| 5 and Table 1(DIMENSIONS OF PIPES - outside diameters) |
- |
250 |
|
- |
| 5 and Table 1(DIMENSIONS OF PIPES - wall thickness shall) |
- |
0 |
|
- |
| 7.2(Reversion Test) |
- |
1000 |
|
- |
| 7.1(Hydraulic Characteristics) |
- |
0 |
|
- |
| 6.1(Visual Appearance) |
- |
300 |
|
- |
| 5.0
5.1
(Table1)
(c)Wall thickness of pipe Maximum) |
- |
250 |
|
- |
| 5.0
5.1
(Table1)
(c)Wall thickness of pipe Minimum) |
- |
0 |
|
- |
| 5.0
5.1
(Table1)
(b)Tolerance on OD) |
- |
0 |
|
- |
| 5.0
5.1
(Table1)
(Dimensions a)Outside diameter of pipe) |
- |
0 |
|
- |
| 3.1(Class of Pipe) |
- |
0 |
|
- |
| 9.0
(9.1)(Minimum Internal Diameter of Coil) |
- |
0 |
|
- |
| 8.0
(8.1)
(Supply of pipes
) |
- |
0 |
|
- |
| 7.1
Table-2
(b)Acceptance Test for 01 hour at 20°C & 6.9MPa induced stress) |
- |
1000 |
|
- |
| 7.1
Table-2
(Hydraulic Characteristics
a)Quality Test for 100 hours at 70°C & 2.5.MPa induced stress.
) |
- |
3000 |
|
- |
|
21 Feb, 2029 |
- - |
| 13965 |
URS PRODUCTS AND TESTING PVT LTD (F3), NOIDA
| 8136826
| IS 366 (1991) |
Electric iron - Specification (Fourth Revision) |
- |
15000 View breakup
Rs. 15000/-
[15% discount to BIS]
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 10.0(Measurement of Heating up time) |
- |
2000 |
|
15% discount to BIS |
| 11.0(Measurement of sole plate temperature) |
- |
2000 |
|
15% discount to BIS |
| 12.0(Measurement of Tempearture Distribution) |
- |
2000 |
|
15% discount to BIS |
| 13.0(Measurement of Initial overswing temperature and Heating up excess temperature) |
- |
500 |
|
15% discount to BIS |
| 13.0(Measurement of Initial overswing temperature and Heating up excess temperature) |
- |
500 |
|
15% discount to BIS |
| 14.0(Measurement of Cyclic fluctuation of temperature of hottest point ) |
- |
1000 |
|
15% discount to BIS |
| 15(MEASUREMENT OF TEMPERATURE DROP UNDER LOAD) |
- |
1000 |
|
15% discount to BIS |
| 16.0(Measurement of Thermostatic staibility) |
- |
500 |
|
15% discount to BIS |
| 16.0(Measurement of Thermostatic staibility) |
- |
500 |
|
15% discount to BIS |
| 16.0(Measurement of Thermostatic staibility) |
- |
500 |
|
15% discount to BIS |
| 16.0(Measurement of Thermostatic staibility) |
- |
500 |
|
15% discount to BIS |
| 16.0(Measurement of Thermostatic staibility) |
- |
500 |
|
15% discount to BIS |
| 16.0(Measurement of Thermostatic staibility) |
- |
500 |
|
15% discount to BIS |
| 17(Measurement of Thermostatic staibility) |
- |
0 |
|
15% discount to BIS |
| 7.0(Classification (as per Cl.6 of IS 302-2-3 and Cl.6.1 of IS 302-1)) |
- |
250 |
|
15% discount to BIS |
| 7.0(Classification (as per Cl.6 of IS 302-2-3 and Cl.6.2 of IS 302-1)) |
- |
250 |
|
15% discount to BIS |
| 9.0(Protection against access to live parts (as per Cl. 8 of IS 302-2-3 and IS 302-1)) |
- |
500 |
|
15% discount to BIS |
| 9.0(Power input and current (as per Cl. 10 of IS 302-2-3 and IS 302-1)) |
- |
1000 |
|
15% discount to BIS |
| 9.0(Temperature Rise (as per Cl. 11 of IS 302-2-3 and IS 302-1)) |
- |
2500 |
|
15% discount to BIS |
| 9.0(Temperature Rise (as per Cl. 11 of IS 302-2-3 and IS 302-1)) |
- |
2500 |
|
15% discount to BIS |
| 9.0(Temperature Rise (as per Cl. 11 of IS 302-2-3 and IS 302-1)) |
- |
2500 |
|
15% discount to BIS |
| 9.0(Temperature Rise (as per Cl. 11 of IS 302-2-3 and IS 302-1)) |
- |
2500 |
|
15% discount to BIS |
| 9.0(Leakage current and Electric Strength at Operating Temperature (as per Cl. 13 of IS 302-2-3 and IS 302-1)) |
- |
250 |
|
15% discount to BIS |
| 9.0(Leakage current and Electric Strength at Operating Temperature (as per Cl. 13 of IS 302-2-3 and IS 302-1)) |
- |
250 |
|
15% discount to BIS |
| 9.0(Transient Overvoltage (as per of Cl. 14 of IS 302-2-3 and Table 6 of IS 302-1)) |
- |
500 |
|
15% discount to BIS |
| 9.0(Moisture Resistance (as per of Cl.15 of IS 302-2-3 and IS 302-1)) |
- |
750 |
|
15% discount to BIS |
| 9.0(Moisture Resistance (as per of Cl.15 of IS 302-2-3 and IS 302-1)) |
- |
750 |
|
15% discount to BIS |
| 9.0(Abnormal Operation (as per of Cl.19 of IS 302-2-3 and IS 302-1) ) |
- |
125 |
|
15% discount to BIS |
| 9.0(Abnormal Operation (as per of Cl.19 of IS 302-2-3 and IS 302-1) ) |
- |
125 |
|
15% discount to BIS |
| 9.0(Abnormal Operation (as per of Cl.19 of IS 302-2-3 and IS 302-1) ) |
- |
125 |
|
15% discount to BIS |
| 9.0(Abnormal Operation (as per of Cl.19 of IS 302-2-3 and IS 302-1) ) |
- |
125 |
|
15% discount to BIS |
| 9.0(Staibilty and mechanical hazards (as per of Cl.20 of IS 302-2-3 and IS 302-1) ) |
- |
500 |
|
15% discount to BIS |
| 9.0(Mechanical strength (as per of Cl.21 of IS 302-2-3 and IS 302-1) ) |
- |
500 |
|
15% discount to BIS |
| 9.0(Construction (as per of Cl.22 of IS 302-2-3 and IS 302-1) ) |
- |
75 |
|
15% discount to BIS |
| 9.0(Construction (as per of Cl.22 of IS 302-2-3 and IS 302-1) ) |
- |
75 |
|
15% discount to BIS |
| 9.0(Construction (as per of Cl.22 of IS 302-2-3 and IS 302-1) ) |
- |
75 |
|
15% discount to BIS |
| 9.0(Construction (as per of Cl.22 of IS 302-2-3 and IS 302-1) ) |
- |
75 |
|
15% discount to BIS |
| 9.0(Construction (as per of Cl.22 of IS 302-2-3 and IS 302-1) ) |
- |
75 |
|
15% discount to BIS |
| 9.0(Construction (as per of Cl.22 of IS 302-2-3 and IS 302-1) ) |
- |
75 |
|
15% discount to BIS |
| 9.0(Construction (as per of Cl.22 of IS 302-2-3 and IS 302-1) ) |
- |
75 |
|
15% discount to BIS |
| 9.0(Internal wiring (as per of Cl.23 of IS 302-2-3 and IS 302-1) ) |
- |
125 |
|
15% discount to BIS |
| 9.0(Internal wiring (as per of Cl.23 of IS 302-2-3 and IS 302-1) ) |
- |
125 |
|
15% discount to BIS |
| 9.0(Internal wiring (as per of Cl.23 of IS 302-2-3 and IS 302-1) ) |
- |
125 |
|
15% discount to BIS |
| 9.0(Internal wiring (as per of Cl.23 of IS 302-2-3 and IS 302-1) ) |
- |
125 |
|
15% discount to BIS |
| 9.0(Components (as per of Cl.24 of IS 302-2-3 and IS 302-1) ) |
- |
500 |
|
15% discount to BIS |
| 9.0(Supply connection and external flexible cord (as per of Cl.25 of IS 302-2-3 and IS 302-1) ) |
- |
125 |
|
15% discount to BIS |
| 9.0(Supply connection and external flexible cord (as per of Cl.25 of IS 302-2-3 and IS 302-1) ) |
- |
125 |
|
15% discount to BIS |
| 9.0(Supply connection and external flexible cord (as per of Cl.25 of IS 302-2-3 and IS 302-1) ) |
- |
125 |
|
15% discount to BIS |
| 9.0(Supply connection and external flexible cord (as per of Cl.25 of IS 302-2-3 and IS 302-1) ) |
- |
125 |
|
15% discount to BIS |
| 9.0(Provision for earthing (as per of Cl.27 of IS 302-2-3 and IS 302-1) ) |
- |
125 |
|
15% discount to BIS |
| 9.0(Provision for earthing (as per of Cl.27 of IS 302-2-3 and IS 302-1) ) |
- |
125 |
|
15% discount to BIS |
| 9.0(Provision for earthing (as per of Cl.27 of IS 302-2-3 and IS 302-1) ) |
- |
125 |
|
15% discount to BIS |
| 9.0(Provision for earthing (as per of Cl.27 of IS 302-2-3 and IS 302-1) ) |
- |
125 |
|
15% discount to BIS |
| 9.0(Screw and connections (as per of Cl.28 of IS 302-2-3 and IS 302-1)) |
- |
250 |
|
15% discount to BIS |
| 9.0(Screw and connections (as per of Cl.28 of IS 302-2-3 and IS 302-1)) |
- |
250 |
|
15% discount to BIS |
| 9.0(Clearances, creepage distances and solid insulation (as per of Cl.29 of IS 302-2-3 and IS 302-1)) |
- |
250 |
|
15% discount to BIS |
| 9.0(Clearances, creepage distances and solid insulation (as per of Cl.29 of IS 302-2-3 and IS 302-1)) |
- |
250 |
|
15% discount to BIS |
| 9.0(Resistance to Heat and Fire (as per of Cl.30 of IS 302-2-3 and IS 302-1)) |
- |
1000 |
|
15% discount to BIS |
| 9.0(Resistance to Rusting (as per of Cl.31 of IS 302-2-3 and IS 302-1)) |
- |
500 |
|
15% discount to BIS |
| 10.0(Measurement of Heating up time) |
- |
- |
|
- |
| 11.0(Measurement of sole plate temperature) |
- |
- |
|
- |
| 11.0(Measurement of sole plate temperature) |
- |
- |
|
- |
| 11.0(Measurement of sole plate temperature) |
- |
- |
|
- |
| 13.0(Measurement of Initial overswing temperature and Heating up excess temperature) |
- |
- |
|
- |
|
31 Dec, 2026 |
- - |
| 13966 |
CENTRAL INSTITUTE OF PETROCHEMICALS ENGINEERING AND TECHNOLOGY (CIPET):CSTS-BHOPAL
| 8100534
| IS 13217 (1991) |
Thermoplastics fumigation covers |
- |
- View breakup
Rs.30550/-
(After 25% discount for BIS)
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
No Record Found
|
|
31 Dec, 2026 |
- Included w.e.f. 29.06.2017. |
| 13967 |
National Test House (NR) - NTH, Ghaziabad
| 8101304
| IS 8978 (1992) |
Specification for electric instantaneous water heaters (Second Revision) |
` |
- View breakup
For BIS samples: BIS approved Testng charges. For Others: Rs.15000 (Inclusive of safety testing charges as per IS 302-2-35 @ Rs.5000/-)
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
No Record Found
|
|
26 Oct, 2028 |
- - |
| 13968 |
CIPET, Jaipur
| 8122834
| IS 13487 (1992) |
Irrigation equipment - Emitters - Specification |
All |
4700 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 7.1(Construction and workmanship) |
- |
300 |
|
- |
| 7.2(Flow path in emitters) |
- |
300 |
|
- |
| 7.3.1(Resistance to Hydrostatic pressure) |
- |
1000 |
|
- |
| 7.3.2(Resistance to Hydrostatic pressure) |
- |
0 |
|
- |
| 7.3.3(Resistance to Hydrostatic pressure) |
- |
0 |
|
- |
| 7.4.1(Emitter Pull Out In-line emitters) |
- |
500 |
|
- |
| 7.4.2(Emitter Pull Out On-line emitters) |
- |
0 |
|
- |
| 8.1.2(Uniformity of Emission Rate Unregulated emitters) |
- |
1000 |
|
- |
| 8.1.2(Uniformity of Emission Rate Unregulated emitters) |
- |
0 |
|
- |
| 8.1.3(Uniformity of Emission Rate Regulated emitters) |
- |
0 |
|
- |
| 8.2.2(Emission rate as a function of inlet pressure Unregulated emitters) |
- |
1000 |
|
- |
| 8.2.3(Emission rate as a function of inlet pressure Regulated emitters) |
- |
0 |
|
- |
| 8.3(Determination of Emitter Exponent) |
- |
600 |
|
- |
| 4(Classification) |
- |
0 |
|
- |
|
21 Feb, 2029 |
- - |
| 13969 |
MSME TESTING CENTRE, CHENNAI
| 6106704
| IS 398 : Part 4 (1994) |
Aluminium conductors for overhead transmission purposes: Part 4 aluminium alloy stranded conductors (Aluminium - Magnesium - Silicon Type) - Specification (Third Revision) |
- |
3150 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 7.1 Table-1(Dimensional measurement of wires) |
- |
630 |
|
for 7 stands |
| 12.2 Table 1(Breaking Load Test- Before Stranding) |
- |
1080 |
|
for 7 stands |
| 12.2 Table 1(Breaking Load Test- After Stranding) |
- |
1080 |
|
for 7 stands |
| 12.3 Table 1(Elongation Test- After Stranding) |
- |
450 |
|
for 7 stands |
| 12.3 Table 1(Elongation Test- Before Stranding) |
- |
450 |
|
for 7 stands |
| 12.4 Table 1(Resistance of Aluminium wire) |
- |
630 |
|
for 7 stands |
| 9.2 Table 3(Lay Ratio of stranded conductors) |
- |
360 |
|
for 7 stands |
|
31 Dec, 2026 |
- - |
| 13970 |
CENTRAL INSTITUTE OF PETROCHEMICALS ENGINEERING AND TECHNOLOGY (CIPET):CSTS-BHOPAL
| 8100534
| IS 5378 (1994) |
Polyethylene cane - Specification (First Revision) |
- |
- View breakup
Rs.3225/-,
Rs.1988/- For Material
(After 25% discount for BIS)
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
No Record Found
|
|
31 Dec, 2026 |
- Included on 29-05-2015 |
| 13971 |
CENTRAL INSTITUTE OF PETROCHEMICALS ENGINEERING AND TECHNOLOGY (CIPET):CSTS-BHOPAL
| 8100534
| IS 6192 (1994) |
Textiles – Monoaxially oriented high density polyethylene tapes – Specification (second revision) |
- |
4600 View breakup
Rs.3450/-
(After 25% discount for BIS)
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4(MATERIAL(Refer IS 7328 :1974)) |
- |
500 |
|
Nil |
| 5.1(Linear density (For test method Refer IS 6193:1971 and IS 7703 Part 1)) |
- |
500 |
|
Nil |
| 5.2(Tenacity (For test method Refer IS 6193:1971)) |
- |
550 |
|
Nil |
| 5.3(Elongation (For test method Refer IS 6193:1971)) |
- |
550 |
|
Nil |
| 5.4(Finished width (For test method Refer IS 6193:1971)) |
- |
250 |
|
Nil |
| 5.5(Thickness (For test method Refer IS 6193:1971)) |
- |
200 |
|
Nil |
| 5.6(Heat Shrinkage at 60 degree C(For test method Refer IS 6193:1971)
) |
- |
850 |
|
NIl |
| 5.6(Heat Shrinkage at 95 degree C(For test method Refer IS 6193:1971)
) |
- |
850 |
|
Nil |
| 5.7( pigmented tapes) |
- |
0 |
|
Nil |
| 5.7( pigmented tapes(Refer IS 2454)) |
- |
850 |
|
Nil |
|
31 Dec, 2026 |
- - |
| 13972 |
CIPET, Hyderabad
| 6111634
| IS 10840 (1994) |
Blow moulded hdpe containers for packing of vanaspati - Specification (Second Revision) |
- |
- View breakup
Rs.4725/-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
No Record Found
|
|
23 Feb, 2027 |
- - |
| 13973 |
CIPET, Hyderabad
| 6111634
| IS 12709 (1994) |
Glass - Fibre reinforced plastic (Grp) pipes joints and fittings for use for potable water supply - Specification (First Revision) |
- |
- View breakup
Rs.44000/-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
No Record Found
|
|
23 Feb, 2027 |
- - |
| 13974 |
CENTRAL INSTITUTE OF PETROCHEMICALS ENGINEERING AND TECHNOLOGY (CIPET):CSTS-BHOPAL
| 8100534
| IS 14182 (1994) |
Solvent cement for use with unplasticized polyvinyl chloride plastic pipe and fittings - Specifications |
- |
8600 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4.1 - Table 1 - v-a(Chemical Resistance - Change in mass, increase) |
- |
0 |
|
- |
| 4.1 - Table 1 - v-a(Chemical Resistance - Change in mass, Decrease) |
- |
0 |
|
- |
| 4.1 - Table 1 - v-b(Chemical Resistance - Change in flexural yield strength, Increase) |
- |
0 |
|
- |
| 4.1 - Table 1 - v-b(Chemical Resistance - Change in flexural yield strength, Decrease) |
- |
0 |
|
- |
| 4.2(Shall be thixotropic and consist substantially of solvents that will swell plastisized PVC polymers and stabilizers) |
- |
0 |
|
- |
| 4.3(Shall be capable of application by brush and shall contain no lumps or foreign matter or macroscopic undissolved particles that will adversely affect the ultimate joint strength or chemical resistance of the material ) |
- |
0 |
|
- |
| 4.4(Shall not show gelation and no evidence of stratification or separation that cannot be removed by stirring) |
- |
0 |
|
- |
| 4.5(When used under the conditions for which they are designed, non metallic materials in contact with or likely to come in contact with potable water shall not constitute a toxic hazard , shall not support microbial growth and shall not give rise to unpleasant taste or odour, cloudiness or discolouration of the water) |
- |
0 |
|
- |
| 4.6(Solvents systems consisting of blends of tetrahydrofuran and cyclohexanone have been found to be acceptable) |
- |
0 |
|
- |
| 4.7(Vinyl Chloride Polymer content - Annex A) |
- |
1100 |
|
- |
| 4.8(Dissolution - Capable of dissolving an additional unplastisized PVC granular, powder compound or resin) |
- |
400 |
|
- |
| 4.5(REQUIREMENTS) |
- |
300 |
|
VISUAL APPEARANCE |
| 4.9 and 6.1(Viscosity) |
- |
0 |
|
Test charges has already been taken in cl. no. 4.9 and 6.1. |
| 4.7 and 6.1(REQUIREMENTS - Vinyl Chloride Polymer Content) |
- |
0 |
|
Test charges has already been taken in cl. no. 4.7 |
| 4.9 and 6.1(Viscosity - Regular) |
- |
0 |
|
Test charges has already been taken in cl. no. 4.9 and 6.1. |
| 4.9 and 6.1(Viscosity - Medium) |
- |
0 |
|
Test charges has already been taken in cl. no. 4.9 and 6.1. |
| 4.9 and 6.1(Viscosity - Heavy ) |
- |
1100 |
|
- |
| 4.10 and 6.1(Lap Shear Strength - After 2 h curing time) |
- |
1100 |
|
- |
| 4.10 and 6.1(Lap Shear Strength - After 10 h curing time) |
- |
1100 |
|
- |
| 4.10 and 6.1(Lap Shear Strength - After 72 h curing time) |
- |
1600 |
|
- |
| 4.11 and 6.1(Hydrostatic Burst Strength - After 2 h curing time) |
- |
850 |
|
- |
|
31 Dec, 2026 |
- - |
| 13975 |
Bharat Test House Pvt Ltd 1474 Sonipat Haryana
| 9135626
| IS 8783 : Part 4 : Sec 3 (1995) |
Winding wires for submersible motors - Specification: Part 4 specification for individual wires: Sec 3 polyester and polypropylene insulated winding wires (First Revision) |
Winding Wires for Submersible Motors |
9500 View breakup
(5% discount for BIS)
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 5.1(The winding wire shall either be wound on spools / reels conforming to IS 482-1981. or supplied in a coils packed and labelled.) |
- |
200 |
|
- |
| 6.1(The winding wire shall carry following information marked on the lable on spool / reel / coil;) |
- |
200 |
|
- |
| 6.1(a) Reference to this Indian Standard;) |
- |
200 |
|
- |
| 6.1(b) Manufacturer's name,brand name or trade-mark;) |
- |
200 |
|
- |
| 6.1(c) Size of conductor / maximum overall diameter,) |
- |
200 |
|
- |
| 6.1(e) Number of lengths onspool / reel / coil (if more than one);) |
- |
200 |
|
- |
| 6.1(f) Country of Manufacturer) |
- |
200 |
|
- |
| 6.1(g) Year of Manufacture.) |
- |
200 |
|
- |
| 4(i) Material) |
- |
750 |
|
- |
| 5(ii) Diameter [mm] Seperate wire:) |
- |
750 |
|
- |
| 5(ii) Diameter [mm] Wire taken from cable:) |
- |
750 |
|
- |
| 5(iii) Annealing test [Percentage] on Seperate wire:) |
- |
750 |
|
- |
| 5(iii) Annealing test [Percentage] on Wire taken from cable:) |
- |
750 |
|
- |
| 5(d) Resistance test [Ohm/km corrected to 20°c) |
- |
750 |
|
- |
| 4.1, table 1 & 2(a) Thickness of Polyster (mm)) |
- |
750 |
|
- |
| 4.1, table 1 & 3(b) Thickness of Polypropylene (mm)) |
- |
750 |
|
- |
| 4.1, table 1 & 4(c) Total thickness of Insulation(mm)) |
- |
750 |
|
- |
| 4.2(Application of insulation) |
- |
750 |
|
- |
| 4.3(Colour of Insuation) |
- |
750 |
|
- |
| 4.4(Overall diameter (mm)) |
- |
750 |
|
- |
| 4(Before ageing Tensile strength [N/mm²]) |
- |
750 |
|
- |
| 4(Before ageing Elongation at break [Percentage]) |
- |
750 |
|
- |
| 4(After ageing Tensile strength [N/mm²]) |
- |
750 |
|
- |
| 4(Variation on tensile strangth [Percentage]) |
- |
750 |
|
- |
| 4(After ageing Elongation at break [Percentage]) |
- |
750 |
|
- |
| 4(Variation on elongation at break [Percentage]) |
- |
750 |
|
- |
| 4(Shrinkage test [Percentage]) |
- |
750 |
|
- |
| 4(After Shrinkage Cracks found.) |
- |
750 |
|
- |
| 4.5(High Voltage test [Water Immersion test] 3 KV for 1 Minute) |
- |
750 |
|
- |
| 4.1(Insulation Resistance test [ohm-cm] At 27 ºC) |
- |
750 |
|
- |
| 4.1([Insulation Resistance test [ohm-cm] At 90 ºC) |
- |
750 |
|
- |
| 5(The winding wire shall either be wound on spools / reels conforming to IS 482-1981. or supplied in a coils packed and labelled.) |
- |
200 |
|
- |
| 6(The winding wire shall carry following information marked on the lable on spool / reel / coil;) |
- |
200 |
|
- |
| 6(a) Reference to this Indian Standard;) |
- |
200 |
|
- |
| 6(b) Manufacturer's name,brand name or trade-mark;) |
- |
200 |
|
- |
| 6(c) Size of conductor / maximum overall diameter,) |
- |
200 |
|
- |
| 6(d) Length of conductor on spool / reel /coil;) |
- |
200 |
|
- |
| 6(e) Number of lengths onspool / reel / coil (if more than one);) |
- |
200 |
|
- |
| 6(f) Country of Manufacturer Marking) |
- |
200 |
|
- |
| 6(g) Year of Manufacture.) |
- |
200 |
|
- |
| 6.2(BIS Certification Mark) |
- |
200 |
|
- |
| 4(i) Material) |
- |
750 |
|
- |
| 4(ii) Diameter [mm] Seperate wire:) |
- |
750 |
|
- |
| 4(ii) Diameter [mm] Wire taken from cable) |
- |
750 |
|
- |
| 4(iii) Annealing test [Percentage] on Seperate wire:) |
- |
750 |
|
- |
| 4([iii) Annealing test [Percentage] on Wire taken from cable:) |
- |
750 |
|
- |
| 4(d) Resistance test [Ohm/km corrected to 20°c]) |
- |
750 |
|
- |
| 4(a) Thickness of Polyster (mm)) |
- |
750 |
|
- |
| 4(b) Thickness of Polypropylene (mm)) |
- |
750 |
|
- |
| 4(c) Total thickness of Insulation(mm)) |
- |
750 |
|
- |
| 4(Application of insulation) |
- |
750 |
|
- |
| 4(Colour of Insuation) |
- |
750 |
|
- |
| 4(Overall diameter (mm)) |
- |
750 |
|
- |
| 4(Before ageing Tensile strength [N/mm²]) |
- |
750 |
|
- |
| 4(Before ageing Elongation at break [Percentage]) |
- |
750 |
|
- |
| 4(After ageing Tensile strength [N/mm²]) |
- |
750 |
|
- |
| 4(Variation on tensile strangth [Percentage]) |
- |
750 |
|
- |
| 4(After ageing Elongation at break [Percentage]) |
- |
750 |
|
- |
| 4(Variation on elongation at break [Percentage]) |
- |
750 |
|
- |
| 4(Shrinkage test [Percentage]) |
- |
750 |
|
- |
| 4(After Shrinkage Cracks found.) |
- |
750 |
|
- |
| 4(Water absorption test [Gravimetric] [mg/cm²]) |
- |
750 |
|
- |
| 4(Hot Deformation test [depth of indentation) [Percentage]) |
- |
750 |
|
- |
| 4(High Voltage test [Water Immersion test] 3 KV for 1 Minute) |
- |
750 |
|
- |
| 4(Insulation Resistance test [ohm-cm] At 27 ºC) |
- |
750 |
|
- |
| 4(Insulation Resistance test [ohm-cm] At 90 ºC) |
- |
750 |
|
- |
| 5.1(The winding wire shall either be wound on spools / reels conforming to IS 482-1981. or supplied in a coils packed and labelled.) |
- |
200 |
|
5% discount for BIS |
| 6.1(The winding wire shall carry following information marked on the lable on spool / reel / coil;) |
- |
200 |
|
5% discount for BIS |
| 6.1(a) Reference to this Indian Standard;) |
- |
200 |
|
5% discount for BIS |
| 6.1(b) Manufacturer's name,brand name or trade-mark;) |
- |
200 |
|
5% discount for BIS |
| 6.1(c) Size of conductor / maximum overall diameter,) |
- |
200 |
|
5% discount for BIS |
| 6.1(e) Number of lengths onspool / reel / coil (if more than one);) |
- |
200 |
|
5% discount for BIS |
| 6.1(f) Country of Manufacturer) |
- |
200 |
|
5% discount for BIS |
| 6.1(g) Year of Manufacture.) |
- |
200 |
|
5% discount for BIS |
| 4(i) Material) |
- |
750 |
|
5% discount for BIS |
| 5(ii) Diameter [mm] Seperate wire:) |
- |
750 |
|
5% discount for BIS |
| 5(ii) Diameter [mm] Wire taken from cable:) |
- |
750 |
|
5% discount for BIS |
| 5(iii) Annealing test [Percentage] on Seperate wire:) |
- |
750 |
|
5% discount for BIS |
| 5(iii) Annealing test [Percentage] on Wire taken from cable:) |
- |
750 |
|
5% discount for BIS |
| 5(d) Resistance test [Ohm/km corrected to 20°c) |
- |
750 |
|
5% discount for BIS |
| 4.1, table 1 & 2(a) Thickness of Polyster (mm)) |
- |
750 |
|
5% discount for BIS |
| 4.1, table 1 & 3(b) Thickness of Polypropylene (mm)) |
- |
750 |
|
5% discount for BIS |
| 4.1, table 1 & 4(c) Total thickness of Insulation(mm)) |
- |
750 |
|
5% discount for BIS |
| 4.2(Application of insulation) |
- |
750 |
|
5% discount for BIS |
| 4.3(Colour of Insuation) |
- |
750 |
|
5% discount for BIS |
| 4.4(Overall diameter (mm)) |
- |
750 |
|
5% discount for BIS |
| 4(Before ageing Tensile strength [N/mm²]) |
- |
750 |
|
5% discount for BIS |
| 4(Before ageing Elongation at break [Percentage]) |
- |
750 |
|
5% discount for BIS |
| 4(After ageing Tensile strength [N/mm²]) |
- |
750 |
|
5% discount for BIS |
| 4(Variation on tensile strangth [Percentage]) |
- |
750 |
|
5% discount for BIS |
| 4(After ageing Elongation at break [Percentage]) |
- |
750 |
|
5% discount for BIS |
| 4(Variation on elongation at break [Percentage]) |
- |
750 |
|
5% discount for BIS |
| 4(Shrinkage test [Percentage]) |
- |
750 |
|
5% discount for BIS |
| 4(After Shrinkage Cracks found.) |
- |
750 |
|
5% discount for BIS |
| 4.5(High Voltage test [Water Immersion test] 3 KV for 1 Minute) |
- |
750 |
|
5% discount for BIS |
| 4.1(Insulation Resistance test [ohm-cm] At 27 ºC) |
- |
750 |
|
5% discount for BIS |
| 4.1([Insulation Resistance test [ohm-cm] At 90 ºC) |
- |
750 |
|
5% discount for BIS |
| 5(The winding wire shall either be wound on spools / reels conforming to IS 482-1981. or supplied in a coils packed and labelled.) |
- |
200 |
|
5% discount for BIS |
| 6(The winding wire shall carry following information marked on the lable on spool / reel / coil;) |
- |
200 |
|
5% discount for BIS |
| 6(a) Reference to this Indian Standard;) |
- |
200 |
|
5% discount for BIS |
| 6(b) Manufacturer's name,brand name or trade-mark;) |
- |
200 |
|
5% discount for BIS |
| 6(c) Size of conductor / maximum overall diameter,) |
- |
200 |
|
5% discount for BIS |
| 6(d) Length of conductor on spool / reel /coil;) |
- |
200 |
|
5% discount for BIS |
| 6(e) Number of lengths onspool / reel / coil (if more than one);) |
- |
200 |
|
5% discount for BIS |
| 6(f) Country of Manufacturer Marking) |
- |
200 |
|
5% discount for BIS |
| 6(g) Year of Manufacture.) |
- |
200 |
|
5% discount for BIS |
| 6.2(BIS Certification Mark) |
- |
200 |
|
5% discount for BIS |
| 4(i) Material) |
- |
750 |
|
5% discount for BIS |
| 4(ii) Diameter [mm] Seperate wire:) |
- |
750 |
|
5% discount for BIS |
| 4(ii) Diameter [mm] Wire taken from cable) |
- |
750 |
|
5% discount for BIS |
| 4(iii) Annealing test [Percentage] on Seperate wire:) |
- |
750 |
|
5% discount for BIS |
| 4([iii) Annealing test [Percentage] on Wire taken from cable:) |
- |
750 |
|
5% discount for BIS |
| 4(d) Resistance test [Ohm/km corrected to 20°c]) |
- |
750 |
|
5% discount for BIS |
| 4(a) Thickness of Polyster (mm)) |
- |
750 |
|
5% discount for BIS |
| 4(b) Thickness of Polypropylene (mm)) |
- |
750 |
|
5% discount for BIS |
| 4(c) Total thickness of Insulation(mm)) |
- |
750 |
|
5% discount for BIS |
| 4(Application of insulation) |
- |
750 |
|
5% discount for BIS |
| 4(Colour of Insuation) |
- |
750 |
|
5% discount for BIS |
| 4(Overall diameter (mm)) |
- |
750 |
|
5% discount for BIS |
| 4(Before ageing Tensile strength [N/mm²]) |
- |
750 |
|
5% discount for BIS |
| 4(Before ageing Elongation at break [Percentage]) |
- |
750 |
|
5% discount for BIS |
| 4(After ageing Tensile strength [N/mm²]) |
- |
750 |
|
5% discount for BIS |
| 4(Variation on tensile strangth [Percentage]) |
- |
750 |
|
5% discount for BIS |
| 4(After ageing Elongation at break [Percentage]) |
- |
750 |
|
5% discount for BIS |
| 4(Variation on elongation at break [Percentage]) |
- |
750 |
|
5% discount for BIS |
| 4(Shrinkage test [Percentage]) |
- |
750 |
|
5% discount for BIS |
| 4(After Shrinkage Cracks found.) |
- |
750 |
|
5% discount for BIS |
| 4(Water absorption test [Gravimetric] [mg/cm²]) |
- |
750 |
|
5% discount for BIS |
| 4(Hot Deformation test [depth of indentation) [Percentage]) |
- |
750 |
|
5% discount for BIS |
| 4(High Voltage test [Water Immersion test] 3 KV for 1 Minute) |
- |
750 |
|
5% discount for BIS |
| 4(Insulation Resistance test [ohm-cm] At 27 ºC) |
- |
750 |
|
5% discount for BIS |
| 4(Insulation Resistance test [ohm-cm] At 90 ºC) |
- |
750 |
|
5% discount for BIS |
| 4.1(Heat Shock Test - No cracks found) |
- |
600 |
|
5% discount for BIS |
|
19 Mar, 2029 |
- Included w.e.f 13.05.2020 |
| 13976 |
DELHI TEST HOUSE, Azadhpur
| 8131406
| IS 14309 (1995) |
Blended edible vegetable oils specification |
- |
9500 View breakup
Rs.9500.00
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Table-1(Moisture and volatile matter percent by mass, Max type1) |
- |
750 |
|
N.A. |
| Table-1(Acid value, mx type 1) |
- |
500 |
|
N.A. |
| Table-1(Unsaponifiable matter, percent by mass, MaX type1) |
- |
500 |
|
N.A. |
| Table-1(Flash point, Pen&y-Martens type1) |
- |
400 |
|
N.A. |
|
17 Jun, 2027 |
- - |
| 13977 |
National Test House (NR) - NTH, Ghaziabad
| 8101304
| IS 1328 (1996) |
Veneered Decorative Plywood -Specification |
BWR/MR/TYPE I/TYPE II |
5000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4.1(Grade - For BWR) |
- |
0 |
|
- |
| 4.1(Grade - For MR) |
- |
0 |
|
- |
| 4.2(Type - For Type 1) |
- |
0 |
|
- |
| 4.2(Type - For Type 2) |
- |
0 |
|
- |
| 7.1.1(Requirements - Open splits, checks or open joints - For Type 1 - Cl. 7.1.1) |
- |
250 |
|
- |
| 7.2.1(Requirements - Open splits, checks or open joints - For Type 2 - Cl. 7.2.1) |
- |
250 |
|
- |
| 7.1.2(Requirements - Other defects - For Type 1 - Cl. 7.1.2) |
- |
250 |
|
- |
| 7.2.2(Requirements - Other defects - For Type 2 - Cl. 7.2.2.) |
- |
250 |
|
- |
| 7.1.3(Requirements - Other Charcteristics and Manufacturing Defects - For Type 1 - Cl. 7.1.3) |
- |
250 |
|
- |
| 7.2.3(Requirements - Other Charcteristics and Manufacturing Defects - For Type 2 - Cl. 7.2.3) |
- |
250 |
|
- |
| 8(Dimensions & Tolerances - Length - Cl. 8) |
- |
250 |
|
- |
| 8(Dimensions & Tolerances - Width - Cl. 8) |
- |
250 |
|
- |
| 8(Dimensions & Tolerances - Thickness - Cl. 8) |
- |
250 |
|
- |
| 8(Dimensions & Tolerances - Edge Straightness - Annexure C) |
- |
250 |
|
- |
| 8(Dimensions & Tolerances - Squareness - Annexure C) |
- |
250 |
|
- |
| 9(Finish - Cl. 9.1, 8.3) |
- |
0 |
|
- |
| 9(Finish - Cl. 9.2, 8.3) |
- |
0 |
|
- |
| 11(Tests - Moisture Content - Part 1 of IS 1734) |
- |
1000 |
|
- |
| 11(Tests - Water Resistance Test - Cl. 11.1.2.1 [for MR Grade]) |
- |
2000 |
|
- |
| 11(Tests - Water Resistance Test - Cl. 11.1.2.2 [for BWR Grade]) |
- |
2000 |
|
- |
|
26 Oct, 2028 |
- - |
| 13978 |
CIPET, Jaipur
| 8122834
| IS 12701 (1996) |
Rotational moulded polyethylene water storage tanks - specification (First Revision) |
Cylindrical & Loft (All) |
18050 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4.2.3(Carbon Black Content ) |
- |
925 |
|
- |
| 4.2.3(Carbon Dispersion Test) |
- |
700 |
|
- |
| 5(Types and Features ) |
- |
0 |
|
- |
| 5.1 Table 1(Dimensioas of Cylinderical Vertical Tank) |
- |
500 |
|
- |
| 5.2 Table 2(Dimensions of Rectangular Loft Tanks) |
- |
500 |
|
- |
| 5.3(Types and Features ) |
- |
0 |
|
- |
| 5.6(Types and Features ) |
- |
0 |
|
- |
| 6.1(Finish) |
- |
300 |
|
- |
| 7.1.1(Resistance to Deformation) |
- |
700 |
|
- |
| 7.1.2(Resistance to Deformation) |
- |
0 |
|
- |
| 7.2(Resistance to Impact) |
- |
1100 |
|
- |
| 7.3(Test for Top Load Resistance) |
- |
900 |
|
- |
| 7.4(Tensile Strength) |
- |
1350 |
|
Testing charge+ Specimen charge ( 1100+250) |
| 7.5(Flexural Modulus) |
- |
1350 |
|
Testing charge+ Specimen charge ( 1100+250) |
| 7.6(overall Migration) |
- |
2200 |
|
Testing charge+ Specimen charge ( 1700+500) |
| 9.2.1(Man-Hole and Hand-Hole Lids) |
- |
200 |
|
- |
| 9.1(Lid Thickness) |
- |
250 |
|
- |
| 5.4(Wall Thickness above effective height) |
- |
250 |
|
- |
| 5.2 Table 2 (7)(Minimum Wall Thickness) |
- |
250 |
|
- |
| 5.1 Table 1 (7)(Minimum Weight of Tank (Without Lid)) |
- |
500 |
|
- |
|
21 Feb, 2029 |
- - |
| 13979 |
CIPET, Jaipur
| 8122834
| IS 14333 (1996) |
High Density Polyethylene Pipe For Sewerage - |
All size |
11475 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 10(Marking) |
- |
0 |
|
- |
| 3(Designation) |
- |
0 |
|
- |
| 4(Colour) |
- |
300 |
|
- |
| 6(Dimensions of pipes) |
- |
250 |
|
- |
| 7(Visual Appearance) |
- |
300 |
|
- |
| 8.1(Hydraulic characteristics) |
- |
6400 |
|
Acceptance test+ Type test (1600+4800) |
| 8.2(Reversion) |
- |
1000 |
|
Testing charges+ Specimen charges (700+300) |
| 8.3(Density) |
- |
500 |
|
- |
| 8.4(Melt Flow Rate) |
- |
1100 |
|
- |
| Cl. 8.5, IS 2530-1963, Cl. 10(Cabon Black Content) |
- |
925 |
|
- |
| Cl. 8.5, IS 2530-1963, Cl. 16(Carbon Black Dispersion) |
- |
700 |
|
- |
|
21 Feb, 2029 |
- - |
| 13980 |
National Test House (NR) - NTH, Ghaziabad
| 8101304
| IS 14333 (1996) |
High Density Polyethylene Pipe For Sewerage - |
- |
12000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 8.2(Reversion) |
- |
1000 |
|
- |
| 8.1(Hydraulic characteristics) |
- |
5000 |
|
- |
| 8.3(Density) |
- |
1500 |
|
- |
| 8.4(Melt Flow Rate) |
- |
1000 |
|
- |
| Cl. 8.5, IS 2530-1963, Cl. 10(Cabon Black Content) |
- |
1000 |
|
- |
| 6(Dimensions of pipes) |
- |
500 |
|
- |
| 10(Marking) |
- |
500 |
|
- |
| 3(Designation) |
- |
500 |
|
- |
| 4(Colour) |
- |
500 |
|
- |
| Cl. 8.5, IS 2530-1963, Cl. 16(Carbon Black Dispersion) |
- |
500 |
|
- |
|