| 14641 |
BIS, Eastern Regional Laboratory (ERL)
| None
| IS 16186 (2014) |
Textiles - Light weight jute sacking bags for packing 50 kg foodgrains - Specification |
All type |
Rs.8150.00 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4.1 (i)The bags shall be made from single piece of 2/1 twill weave jute sacking of uniform construction with warp running along the length of the bag. ) |
- |
|
|
|
| 4.1 (ii) The mass per square meter of sacking used in the fabric of the bag 504 g.) |
- |
|
|
|
| 4.2.i) ( Type of stitches Herakle ) |
- |
|
|
|
| 4.2.ii) ( Jute twine for stitches Two strands of 3-ply ) |
- |
|
|
|
| 4.2.iii) ( Stitches/dm 10 ± 1 ) |
- |
|
|
|
| 4.2.iv) (Tex of jute twine [ IS 9113 (Cl.5.1.2) ] 310 tex.X 3-ply ) |
- |
|
|
|
| 4.3.i) ( Stitches/dm 10 ± 1 ) |
- |
|
|
|
| 4.3.ii) (Tex of jute twine ) |
- |
|
|
|
| 4.4 (Fabric shall be hemmed with jute yarn of 310 tex ) |
- |
|
|
|
| 4.5, Annex A (GAW) |
- |
|
|
|
| 4.5, Annex A (Multiple broken/missing warp(end)-Two or more contiguous,
regardless of length
) |
- |
|
|
|
| 4.5, Annex A (Multiple broken weft(pick)) |
- |
|
|
|
| 4.5, Annex A (Cut, hole, tear or patch-Two or more warp
thread ruptured at adjoining points
) |
- |
|
|
|
| 4.5, Annex A (Float-Fabric where warp and weft yarns escape) |
- |
|
|
|
| 4.5, Annex A (Gap stitching-Stitching missing) |
- |
|
|
|
| 4.5, Annex A (Corner gap-Hole formation due to improper
stitching at the corner of the bag
) |
- |
|
|
|
| 4.5, Annex A (Mildew-Staining of fabric due to fungal or bacterial growth visible to naked eye) |
- |
|
|
|
| 4.1 & 5.1, Table 1 (Outside Length, cm ) |
- |
|
|
|
| 4.1 & 5.1, Table 1 (Outside Width, cm ) |
- |
|
|
|
| 4.1 & 5.1, Table 1 (Ends /dm-IS 9113 (Cl.8.4.2)) |
- |
|
|
|
| 4.1 & 5.1, Table 1 (Picks/dm-IS 9113 (Cl.8.4.2)) |
- |
|
|
|
| 4.1 & 5.1, Table 1 (Corrected Mass/Bag,g-IS 9113 (Cl.8.5.2)) |
- |
|
|
|
| 4.1 & 5.1, Table 1 (Warpway -IS 9113 (Cl.8.6.2)) |
- |
|
|
|
| 4.1 & 5.1, Table 1 (Weftway-IS 9113 (Cl.8.6.2)) |
- |
|
|
|
| 4.1 & 5.1, Table 1 (Moisture Regain, Percent-IS 9113 (Cl.8.2)) |
- |
|
|
|
| 4.1 & 5.1, Table 1 (Oil content, Percent-IS 9113 (Cl.8.5.2)) |
- |
|
|
|
| 4.1 & 5.1, Table 1 (Average Seam Strength in N-IS 9113 (Cl.8.7)) |
- |
|
|
|
| 4.4 (Hemming at the mouth-IS 9113 (Cl.5.1.2)) |
- |
|
|
|
| 4 (Manufacture- IS16186) |
- |
|
|
|
| 4.1 (Fabric) |
- |
|
|
|
| 4.2 (Seam-IS 9113 (Cl.5.1.2)) |
- |
|
|
|
| 4.3 (Union Safety Stitch-IS 9113 (Cl.5.1.2)) |
- |
|
|
|
| 4.5 (Freedom from defects) |
- |
|
|
|
| 4.1 & 5.1, Table 1 (Dimension-IS 9113 (Cl.8.3.2)) |
- |
|
|
|
| 4.1 & 5.1, Table 1 (Average Breaking Strength in N) |
- |
|
|
|
| 4.3 ( 310 tex.X 2-ply ) |
- |
|
|
|
|
- |
- Type to be Declared. Separately Yarns(1 Ply,3 Ply) + Fabric + 2 Ply Yarn to be provided if safety stitch is present |
| 14642 |
BIS, Central Laboratory (CL)
| None
| IS 14186 (1994) |
Pesticide - Diflubenzuron WP - specification |
- |
4390 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 3.2 (Description) |
- |
|
|
|
| 3.3 Table 1 ii (Sieving requirements material passing through 44 micron IS sieve) |
- |
|
|
|
| 3.3 Table 1 v (Wettability) |
- |
|
|
|
| 3.3 Table 1 iv (Acidity (as H2SO4)) |
- |
|
|
|
| 3.3 Table 1 i (Diflubenzuron content ) |
- |
|
|
|
| 3.3 Table 1 iii (Suspensibility) |
- |
|
|
|
|
- |
- - |
| 14643 |
BIS, Southern Regional Laboratory (SRL)
| None
| IS 738 (1994) |
Wrought aluminium alloys, drawn tube for general engineering purposes - Specification (Third Revision) |
- |
- View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl. 6 (Freedom from Defects- Cl.6) |
- |
|
|
|
| Cl.7, IS 2678 (Wall Thickness at any point) |
- |
|
|
|
| Cl.7, IS 2678 (Mean Wall Thickness) |
- |
|
|
|
| Cl.7, IS 2678 (Straightness) |
- |
|
|
|
| Cl. 9.1 Table 2 (Tensile Strength- IS 2657) |
- |
|
|
|
| Cl. 9.1 Table 2 (Elongation on guage length of 50 mm) |
- |
|
|
|
| Cl. 9.1 Table 2 (Tensile Strength- IS 2657) |
- |
|
|
|
| Cl. 9.1.2 (Flattening Test- IS 2328) |
- |
|
|
|
|
- |
- Excluding except proof stress.chem facility not available. |
| 14644 |
BIS, Central Laboratory (CL)
| None
| IS 1155 (1968) |
Specification for wheat aita (Second Revision) |
- |
Rs. 900 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| CL 3.1 (Decription) |
- |
|
|
|
| Table 1 (i), Annex A (Moisture LG) |
- |
|
|
|
| Table 1 (i), Annex A (Moisture HG) |
- |
|
|
|
| Table 1 (ii), Annex B (Total Ash (on dry basis) LG) |
- |
|
|
|
| Table 1 (ii), Annex B (Total Ash (on dry basis) HG) |
- |
|
|
|
| Table 1 (iii), Annex C (Add insoluble Ash (on dry basis) LG) |
- |
|
|
|
| Table 1 (iii), Annex C (Add insoluble Ash (on dry basis) HG) |
- |
|
|
|
| Table 1 (iv), Annex D (Glutin (on dry basis) LG) |
- |
|
|
|
| Table 1 (iv), Annex D (Glutin (on dry basis) HG) |
- |
|
|
|
| Table 1 (v), Annex E (Crude Fibre (on dry basis) LG) |
- |
|
|
|
| Table 1 (v), Annex E (Crude Fibre (on dry basis) HG) |
- |
|
|
|
| Table 1 (vi), Annex F (Alcoholic acidity (As H2SO4.), with 90 prcent Alcohol (on dry basis) LG) |
- |
|
|
|
| Table 1 (vi), Annex F (Alcoholic acidity (As H2SO4.), with 90 prcent Alcohol (on dry basis) HG) |
- |
|
|
|
| Table 1 (vii), Annex G (Granularity(on dry basis) LG) |
- |
|
|
|
| Table 1 (vii), Annex G (Granularity(on dry basis) HG) |
- |
|
|
|
|
- |
- excluding 1- Uric acid, 2-Granularity, 3-Microscopic Appearance; |
| 14645 |
BIS, Eastern Regional Laboratory (ERL)
| None
| IS 5517 (1993) |
Steels for hardening and tempering - Speicification (Second Revision) |
- |
Please see remarks. View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl. 6.1, 6.2, 6.3, 11.2, 15.1 & Table 2 (Carbon- IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
|
|
|
| Cl. 6.1, 6.2, 6.3, 11.2, 15.1 & Table 2 (Manganese- IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
|
|
|
| Cl. 6.1, 6.2, 6.3, 11.2, 15.1 & Table 2 (Silicon- IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
|
|
|
| Cl. 6.1, 6.2, 6.3, 11.2, 15.1 & Table 2 (Nickel- IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
|
|
|
| Cl. 6.1, 6.2, 6.3, 11.2, 15.1 & Table 2 (Chromium- IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
|
|
|
| Cl. 6.1, 6.2, 6.3, 11.2, 15.1 & Table 2 (Molybdenum- IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
|
|
|
| Cl. 6.1, 6.2, 6.3, 11.2, 15.1 & Table 2 (Sulphur- IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
|
|
|
| Cl. 6.1, 6.2, 6.3, 11.2, 15.1 & Table 2 (Phosphorus- IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
|
|
|
| Cl. 6.1, 6.2, 6.3, 11.2, 15.1 & Table 2 (Copper- IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
|
|
|
| Cl. 6.1, 6.2, 6.3, 11.2, 15.1 & Table 2 (Aluminium IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
|
|
|
| 5 (Freedom from defects , IS 5517) |
- |
|
|
|
| 8,Table 6 (Hardness Test - IS 1500(Pt -1)) |
- |
|
|
|
| 9, Table 5 (Mechanical ptoperties - IS 1608(Pt -1),IS 1598) |
- |
|
|
|
| 13.1&13.2&13.3 (Dimensional tolerances- IS 3739 and is 3469(Pt 1to 3); Tolerance on straightness) |
- |
|
|
|
| 10 (Grain Size - IS 4748) |
- |
|
|
|
| 11.1 (Inclusion Rating- IS 4163) |
- |
|
|
|
|
- |
- Facility not available for Additional tests (Ultrasonic test, Hot up-set for forgeability). Steel designation, delivery condition & Forging Temp to be declared. |
| 14646 |
BIS, Central Laboratory (CL)
| None
| IS 14300 (1995) |
Neem based EC containing azadirachtin - Specification |
- |
Rs. 1552/- (excluding Azadirachtin content and Aflatox View breakup
Rs. 1552/- (excluding Azadirachtin content and Aflatoxin content).
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl. 3.2.1 (Description) |
- |
|
|
|
| Cl. 3.2.2 (Cold Test) |
- |
|
|
|
| Cl. 3.2.3 (Flash point) |
- |
|
|
|
| Cl. 3.2.4 (Emulsion Stability) |
- |
|
|
|
| Cl. 3.2.1 (Description) |
- |
|
|
|
|
- |
- excluding Cl. 3.3.1 & Cl. 3.3.3 Azadirachtin Content, Aflatoxin content; |
| 14647 |
BIS, Central Laboratory (CL)
| None
| IS 7312 (2018) |
Welded and seamless steel dissolved acetylene gas cylinders - Specification (Third Revision) |
- |
- View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl. 4.1, IS 6240-2008 , Cl 6.2 (Carbon Content) |
- |
|
|
|
| Cl. 4.1, IS 6240-2008 , Cl 6.2 (Sulphur Content) |
- |
|
|
|
| Cl. 4.1, IS 6240-2008 , Cl 6.2 (Phosphorous Content) |
- |
|
|
|
| Cl. 4.1, IS 6240-2008 , Cl 6.2 (Manganese Content) |
- |
|
|
|
| Cl. 4.1, IS 6240-2008 , Cl 6.2 (Aluminium Content) |
- |
|
|
|
| Cl. 4.1, IS 6240-2008 , Cl 6.2 (Silicon Content) |
- |
|
|
|
| Cl. 4.1, For Seamless - IS 7285 (P-1)-2018, Cl 5.2 , Table-1 & 2 (Carbon Content) |
- |
|
|
|
| Cl. 4.1, For Seamless - IS 7285 (P-1)-2018, Cl 5.2 , Table-1 & 2 (Combined Value Of Micro-Alloying Elements like V, Nb, Ti, B, Zr, Sn) |
- |
|
|
|
| Cl. 4.1, For Seamless - IS 7285 (P-2)-2017, Cl 5.2 , Table-1, 2 (Carbon Content) |
- |
|
|
|
| Cl. 4.1, For Seamless - IS 7285 (P-2)-2017, Cl 5.2 , Table-1, 2 (Sulphur + Phosphorous Content) |
- |
|
|
|
| Cl. 4.3 , For Footing Material, Grade HR1 (Desig Commertial) Of IS 1079-2017, Cl. 7.2, Table 3 & 4 (Carbon Content) |
- |
|
|
|
| Cl. 4.3 , For Footing Material, Grade HR1 (Desig Commertial) Of IS 1079-2017, Cl. 7.2, Table 3 & 4 (if addition of Micro Alloying Elements like B, TI, Nb,& V either single of Combination) |
- |
|
|
|
| Cl. 4.2 , For Bung / Valve, as per IS 2062-2011, Grade / Desig - E-250, Quality - A (Carbon Content) |
- |
|
|
|
| Cl. 4.2 , For Bung / Valve, as per IS 2062-2011, Grade / Desig - E-250, Quality - A (Sulphur Content) |
- |
|
|
|
| Cl. 4.2 , For Bung / Valve, as per IS 2062-2011, Grade / Desig - E-250, Quality - A (Phosphorus Content) |
- |
|
|
|
| Cl. 4.2 , For Bung / Valve, as per IS 2062-2011, Grade / Desig - E-250, Quality - A (Manganese Content) |
- |
|
|
|
| Cl 4.2 , Class 1A Desig 15C8 of IS 1875-1992, Cl 6.1 & 6.2 For section 250 mm2 or Less (Carbon Content, IS 228) |
- |
|
|
|
| Cl 4.2 , Class 2 Desig 20C8 of IS 1875-1992, Cl 6.1 & 6.2 for section 250 mm2 or less (Carbon Content, IS 228) |
- |
|
|
|
| 9,9.1 (VALVES AND VALVES PAD) |
- |
|
|
|
| 9.2 (Valve Protection
The valve shall be protected by a stout metal cap
perforated for ventilation and of thickness not less than
3.5 mm, screwed on to the neck, or in any other manner
approved by the statutory authority.) |
- |
|
|
|
| 9.3 (Valves) |
- |
|
|
|
| 10,10.1 (FITTINGS OTHER THAN VALVES
Footring) |
- |
|
|
|
| 10,10.1 (FITTINGS OTHER THAN VALVES
Footring
) |
- |
|
|
|
| 10,10.1 (FITTINGS OTHER THAN VALVES
Footring) |
- |
|
|
|
| 10,10.1 (FITTINGS OTHER THAN VALVES
Footring
The
bottom of the foot ring shall not be less than 8 mm
below the outside bottom of the cylinder shell for
cylinders up to 34 l nominal water capacity. For
cylinders of more than 34
l itresnominal water capacity
and up to 50 litres nominal water capacity, this value shall
be minimum 15 mm and for cylinders exceeding 50 Iiters
nominal water capacity, this value shall be minimum 25 mm) |
- |
|
|
|
| 10.2,10.2.1
IS 13497
(Safety Device) |
- |
|
|
|
| 10.2.2 (Safety Device) |
- |
|
|
|
| 14 (CHECKING OF WATER CAPACITY
The water capacity of the cylinders shall be checked.
This shall be done by weighing or by volumetric
method. Water capacity of the cylinder shall have atolerance of + 3/-0
percent on the declared value.
) |
- |
|
|
|
| 15.1
IS 3196(Part 3) (Hydrostatic Stretch Test:
Permanent volumetric expansion suffered by the
cylinder due to application of test pressure shall not
exceed 7.5 percent of the total volumetric expansion at
the pressure.) |
- |
|
|
|
| 15.2
IS 3196(Part 3) (Hydrostatic Test) |
- |
|
|
|
| 16
IS 3196(Part 3) (Pneumatic Leakage Test) |
- |
|
|
|
| 17
IS 3196(Part 3) (BURST TEST) |
- |
|
|
|
| 18
IS 3196(Part 3) (ACCEPTANCE TESTS
) |
- |
|
|
|
| 18g
IS 3196(Part 3) (c)Weld Joint test specimen) |
- |
|
|
|
| 18j
IS 3196(Part 3) (d)Bend test Across weld
Root Bend test,) |
- |
|
|
|
| 18k
IS 3196(Part 3) (Face Bend test,) |
- |
|
|
|
| 18h
IS 3196(Part 3) (c)Weld Joint test specimen) |
- |
|
|
|
| 18j
IS 3196(Part 3) (d)Bend test Across weld
Root Bend test,) |
- |
|
|
|
| 18k
IS 3196(Part 3) (Face Bend test,) |
- |
|
|
|
| 18m
IS 3196(Part 3) (e)Macro Examination:
Body) |
- |
|
|
|
| 18p
IS 3196(Part 3) (f) Minimum Thickness test:
The thickness shall not be less than agreed finished thickness,Declared thicknes:) |
- |
|
|
|
| 19.2.1 (Porous Material) |
- |
|
|
|
| 19.2.3 (Gap between cylinder shell and porous material:
Overall shrinkage of the filling material is permissible
provided that the total clearance between the cylinder
shell and filling material does not exceed 0.5 percent
of the respective diameter or length but in no case of
exceed 3.2 mm measured diametrically and
longitudinally and that such clearances do not impair
the functions of the filling material.) |
- |
|
|
|
| 19.2.4
Annex B (The porosity of the porous filling shall be in the range of 75 to 92 percent with a tolerance of ± 2 percent on nominal declared value as determined by the method prescribed in Annex B) |
- |
|
|
|
| 19.2.5
Annex C (The crushing strength of the porous filling shall be 2 156 kN/m2 (22 kgf/cm2 ) minimum as determined by the method prescribed in Annex C) |
- |
|
|
|
| 19.3 (Solvent and Acetylene Content) |
- |
|
|
|
| 20.2.4e)
Annex E (Test of the Integrity of porous material) |
- |
|
|
|
| 20.3 (Elevated Temperature Test) |
- |
|
|
|
| 20.4 (Vibration Test) |
- |
|
|
|
| 20.5 (Backfire Test) |
- |
|
|
|
| 20.6 (Bonfire Test) |
- |
|
|
|
|
- |
- Element to be tested for material with specified requirement to be declared.Sample size shall be minimum dia> 3mm and thickness > 0.8 mm;
excluding "-; CL 20.6 -Bonfire Test, CL 20.5 Backfire Test ,CL 20.4 Vibration Test ,Cl 20.3 Elevated
Temperature Test, CL -19.2.1 Porous Material, CL 16 IS 3196(Part
3)
Pneumatic Leakage
Test,CL 15.1 IS
3196(Part 3)
Hydrostatic Stretch
Test, CL (Cl 13)-Radiographic examination" |
| 14648 |
BIS, Northern Regional Laboratory (NRL)
| None
| IS 14846 (2000) |
Sluice valve for water works purposes (50 To 1200 mm size) - specification |
- |
complete testing charges for the product are Rs.5700.00 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 5.1 (Nominal Sizes) |
- |
|
|
|
| 5.1.1 (Actual Bore) |
- |
|
|
|
| 6 (Material) |
- |
|
|
|
| 7.2.1 (Manufacture - Bodies and Bonnets) |
- |
|
|
|
| 7.2.2 (Manufacture - Bodies and Bonnets) |
- |
|
|
|
| 7.2.3 (Manufacture) |
- |
|
|
|
| 7.2.4 (Manufacture) |
- |
|
|
|
| 7.3 Table 3A 1 (Flanges) |
- |
|
|
|
| 7.3 Table 3A 2 (Flanges) |
- |
|
|
|
| 7.3 Table 3A 3 (Flanges) |
- |
|
|
|
| 7.3 Table 3A 4 (Flanges) |
- |
|
|
|
| 7.3 Table 3A 5 (Flanges) |
- |
|
|
|
| 7.3 Table 3A 6 (Flanges) |
- |
|
|
|
| 7.4.1 (Wedges ) |
- |
|
|
|
| 7.4.1 (Wedges) |
- |
|
|
|
| 7.4.1 (Wedges) |
- |
|
|
|
| 7.4.2 (Wedge Faces) |
- |
|
|
|
| 7.5 (Guides and Lugs) |
- |
|
|
|
| 7.5.1 (Guides and Lugs) |
- |
|
|
|
| 7.6 Table 4 (Facing or Seat Rings) |
- |
|
|
|
| 7.6 Table 4 (Facing or Seat Rings) |
- |
|
|
|
| 7.6 Table 4 (Facing or Seat Rings) |
- |
|
|
|
| 7.6 Table 4 (Facing or Seat Rings) |
- |
|
|
|
| 7.7.1 Table 2,3 (Dimension of Stem and Wedge Nuts) |
- |
|
|
|
| 7.7.1 Table 2,3 (Dimension of Stem and Wedge Nuts) |
- |
|
|
|
| 7.7.1 Table 2,3 (Dimension of Stem and Wedge Nuts) |
- |
|
|
|
| 7.7.1 Table 2,3 (Dimension of Stem and Wedge Nuts) |
- |
|
|
|
| 7.7.1 Table 2,4 (Dimension of Stem and Wedge Nuts) |
- |
|
|
|
| 7.7.1 Table 2,5 (Dimension of Stem and Wedge Nuts) |
- |
|
|
|
| 7.7.2 (Stem and Wedge Nuts) |
- |
|
|
|
| 7.7.3 (Stem and Wedge Nuts) |
- |
|
|
|
| 7.7.4 (Stem and Wedge Nuts) |
- |
|
|
|
| 7.9 (Height of Valve) |
- |
|
|
|
| 7.11 (Hand Wheel) |
- |
|
|
|
| 7.11 (Hand Wheel) |
- |
|
|
|
| 7.11 (Hand Wheel) |
- |
|
|
|
| 7.12 (Valve Caps) |
- |
|
|
|
| 7.12 (Valve Caps) |
- |
|
|
|
| 7.12 (Valve Caps) |
- |
|
|
|
| 7.12 (Valve Caps) |
- |
|
|
|
| 7.13 Table 2, 3 (Stuffing Box ) |
- |
|
|
|
| 7.13 Table 2, 3 (Stuffing Box ) |
- |
|
|
|
| 7.13 Table 2, 3 (Stuffing Box ) |
- |
|
|
|
| 7.13 Table 2, 3 (Stuffing Box ) |
- |
|
|
|
| 7.14 (By Pass Arrangements) |
- |
|
|
|
| 7.14 (By Pass Arrangements) |
- |
|
|
|
| 8 (Accessories or Optical Features) |
- |
|
|
|
| 9 (Coating) |
- |
|
|
|
| 10.1 Annex B-1 (Hydraulic Test) |
- |
|
|
|
| 10.1 Annex B-2 (Hydraulic Test) |
- |
|
|
|
| 10.2 (Flaw Detection Test for Stems) |
- |
|
|
|
|
- |
- Facility for chemical test is not available and HST above 300 mm |
| 14649 |
BIS, Eastern Regional Laboratory (ERL)
| None
| IS 4224 (1972) |
Specification for steel wire for staples, pins and clips (First Revision) |
For all types |
525 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl. 3.1, Table 1 (Carbon- IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
|
|
|
| Cl. 3.1, Table 1 (Manganese- IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
|
|
|
| Cl. 3.1, Table 1 (Sulphur- IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
|
|
|
| Cl. 3.1, Table 1 (Phosphorus- IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
|
|
|
| 4 (Freedom from defects , IS 4224) |
- |
|
|
|
| 5 (Sizes and Tolerances - IS 4224) |
- |
|
|
|
| 7.1 (Tensile Test - IS 1608(Pt -1)) |
- |
|
|
|
| 7.2 (Reverse Bend Test--IS 1716) |
- |
|
|
|
| 6 (Finish) |
- |
|
|
|
|
- |
- Facility not available for finish (other than galvanized) |
| 14650 |
BIS, Western Regional Laboratory (WRL)
| None
| IS 13334 : Part 2 (2014) |
Skimmed milk powder - Specification: Part 2 extra grade (First Revision) |
- |
Rs 10430/- View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Table 1 (i) (Moisture (IS 116231or 16072)) |
- |
|
|
|
| Table 1 (ii) (Milk protein in milk solids not fat (IS 72192)) |
- |
|
|
|
| Table 1 (iii) (Milk fat (IS 117213) or Annex B) |
- |
|
|
|
| Table 1 (iv) (Insolubility index (IS 12759)) |
- |
|
|
|
| Table 1 (v) (Total ash (on dry basis), Annex B of IS 14433) |
- |
|
|
|
| Table 1 (vi) (Titratable acidity (IS 11766)) |
- |
|
|
|
| Table 1 (ix) (Bacterial count (IS 5402)) |
- |
|
|
|
| Table 1 (x) (Coliform count (IS 5401 - Part 1)) |
- |
|
|
|
| Table 1 (xi) (Escherichia coli (IS 5887 - Part 1)) |
- |
|
|
|
| Table 1 (xii) (Coagulase positive Staphylococcus aureus (IS 5887 - Part 2)) |
- |
|
|
|
| Table 1 (xiii) (Salmonella (IS 5887 - Part 3)) |
- |
|
|
|
| Table 1 (xiv)(a) (Spore Count: a)Aerobic (Bacillus cereus) Type m (IS 5887 - Part 6)) |
- |
|
|
|
| Table 1 (xiv)(b) (Spore Count: b) Anaerobic (Sulfite reducing Clostridia) Type m (ISO 15213 : 2003)) |
- |
|
|
|
| Table 1 (xv) (Listeria monocytogenes (IS 14988 - Part 2 : 2001)) |
- |
|
|
|
| Table 1 (viii) (Scorched particles (equivalent to Disc B) (IS 13500)) |
- |
|
|
|
|
- |
- Test facility not available for the following:
(1) As per Cl. 5.7 The pesticide residues, heavy metals, toxins (aflatoxins and other naturally occurring toxins) and contaminants, if any, in the product shall not exceed the limits as prescribed in the Food Safety and Standards (Contaminants, Toxins and Residues) Regulations, 2011.’ |
| 14651 |
BIS, Central Laboratory (CL)
| None
| IS 1239 : Part 2 (2011) |
Steel tubes, tubulars and other steel fittings - Specification: Part 2 steel pipe fittings (Fifth Revision) |
- |
3400 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 8.1-Table 1 ( DIMENSIONS OF TUBULARS-Pieces
) |
- |
|
|
|
| 8.2-Table-2 ( DIMENSIONS OF TUBULARS-Nipples
) |
- |
|
|
|
| 8.2-Table-2 ( DIMENSIONS OF TUBULARS-Nipples-B
) |
- |
|
|
|
| 8.2-Table-2 ( DIMENSIONS OF TUBULARS-Nipples-C
) |
- |
|
|
|
| 8.3.1-Table 3 (DIMENSIONS OF TUBULARS-Longscrews (Connectors)) |
- |
|
|
|
| 8.3.1-Table 3 (DIMENSIONS OF TUBULARS-Longscrews (Connectors)-A) |
- |
|
|
|
| 8.3.1-Table 3 (DIMENSIONS OF TUBULARS-Longscrews (Connectors)-B) |
- |
|
|
|
| 8.3.1-Table 3 (DIMENSIONS OF TUBULARS-Longscrews (Connectors)-C) |
- |
|
|
|
| 7.1 (Chemical Composition - Sulphur - Laddle Analysis IS 228) |
- |
|
|
|
| 7.1 (Chemical Composition - Phosphorus - Laddle Analysis IS 228) |
- |
|
|
|
|
- |
- Sample size shall be minimum dia> 3mm and thickness > 0.8 mm;
excluding -; i)Alignment of threads(CL 9..2) ii)Joints(CL 10) iii)Taper screw plug test (CL11.2.2) |
| 14652 |
BIS, Central Laboratory (CL)
| None
| IS 7291 (1981) |
Specification for high speed tool steels (First Revision) |
- |
- View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl. 5.1, 5.2 & 14.1 (Carbon- IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
|
|
|
| Cl. 5.1, 5.2 & 14.1 (Sulphur- IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
|
|
|
| Cl. 5.1, 5.2 & 14.1 (Phosphorus- IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
|
|
|
| Cl. 5.1, 5.2 & 14.1 (Manganese- IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
|
|
|
| Cl. 5.1, 5.2 & 14.1 (Silicon- IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
|
|
|
|
- |
- Standard has been withdrawn; |
| 14653 |
BIS, Central Laboratory (CL)
| None
| IS 14411 (1996) |
Deltamethrin F - Specification |
- |
Rs.2300.00 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 3.2 (Description) |
- |
|
|
|
| 3.3 (Deltamethrin Content) |
- |
|
|
|
| 3.4 (Dispersibility in -Water) |
- |
|
|
|
| 3.5 (Acidity) |
- |
|
|
|
|
- |
- - |
| 14654 |
BIS, Central Laboratory (CL)
| None
| IS 1011 (2002) |
Biscuits - Specification (Fourth Revision) |
- |
Rs.3280/- View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 6.1 (General Requirement) |
- |
|
|
|
| 6.3 Table 2 i (Moisture) |
- |
|
|
|
| 6.3 Table 2 ii (Acid insoluble ash (on dry basis)) |
- |
|
|
|
| 6.3 Table 2 iii (Acidity of extracted fat (as oleic acid)) |
- |
|
|
|
|
- |
- 3 PKT |
| 14655 |
BIS, Eastern Regional Laboratory (ERL)
| None
| IS 4223 (1975) |
Steel Wire For Umbrella Ribs |
all grades |
- View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl 6.1 (Sulphur- Appropriate parts of IS 228.) |
- |
|
|
|
| Cl. 6.1 (Sulphur- IS 228(Part 9)) |
- |
|
|
|
| Cl 6.1 (Phosphorus- Appropriate parts of IS 228.) |
- |
|
|
|
| Cl. 6.1 (Phosphorous- IS 228(Part 3)) |
- |
|
|
|
| 7 (Freedom rom defects , IS 4223) |
- |
|
|
|
| 8,9 (Sizes and Tolerances - IS 4223) |
- |
|
|
|
| 10.1, Table 1 (Mechanical ptoperties - IS 1608(Pt -1)) |
- |
|
|
|
| 10.4 ( Straightness Test - IS 4223) |
- |
|
|
|
| 10.5 (Deflection Test - IS 4223) |
- |
|
|
|
| 10.2 (Torsion Test - IS 1717) |
- |
|
|
|
| 10.3 (Reverse Bend Test--IS 1716) |
- |
|
|
|
| 12 (Rust Protection-IS 4223) |
- |
|
|
|
|
- |
- Complete |
| 14656 |
BIS, Bengaluru Branch Laboratory (BNBL)
| None
| IS 398 : Part 2 (2025) |
Aluminium Conductor for Overhead Transmission Purposes - Specification Part 2 Aluminium Conductors Galvanized Steel Reinforced (Fourth Revision) |
- |
Please see remarks. View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl-7 (Freedom From Defects) |
- |
|
|
|
| Cl-8.1 (Wires-Nominal Sizes) |
- |
|
|
|
| Cl-8.2 (Aluminum Conductors, Galvanized Steel- Reinforced) |
- |
|
|
|
| Cl-9.1 (Joint in Wires) |
- |
|
|
|
| Cl-9.2 (Aluminium Wires) |
- |
|
|
|
| Cl-9.3 (Galvanized Steel Wires) |
- |
|
|
|
| Cl-10.2 (Lay Ratio of Aluminium Conductors Galvanized Steel-Reinforced) |
- |
|
|
|
| Cl-11.1 (Standard Length) |
- |
|
|
|
| Cl-11.2 (Random Lengths) |
- |
|
|
|
| Cl-13.3 (Conductor- Visual examination) |
- |
|
|
|
| Cl- 13.5 (Conductor- Measurement of lay ratio/direction of lay) |
- |
|
|
|
| Cl- 13.6 (Aluminium wires -Breaking load test) |
- |
|
|
|
| Cl- 13.6 (Steel wires- Breaking load test) |
- |
|
|
|
| Cl-13.7.2 (Elongation Test) |
- |
|
|
|
| Cl- 13.7 (Steel wires- Ductility test) |
- |
|
|
|
| Cl- 13.8 (Aluminium wires- Wrapping test) |
- |
|
|
|
| Cl-13.7.1 (Torsion Test) |
- |
|
|
|
| Cl- 13.8 (Steel wires- Wrapping test) |
- |
|
|
|
| Cl- 13.10 (Steel wires- Galvanizing test) |
- |
|
|
|
| Cl- 13.9 (Aluminium wires- d.c. resistance test) |
- |
|
|
|
| Cl- 13.4 (Steel wires- Measurement of diameter) |
- |
|
|
|
| Cl-13.4 (Aluminium wires-Measurement of diameter) |
- |
|
|
|
|
- |
- Partial*
* All Test facilities for conductors up to 80 sq. mm available, excluding Cl 13.15 Corona Test & Cl 13.16 Radio Interference Voltage Test.
* Test facilities for conductors of nominal area 100 sq mm and above available. excluding Cl 13.12 Resistance test on stranded conductor, Cl 13.13 Surface Condition test, Cl 13.14 Ultimate Tensile Strength Test on Stranded conductor, Cl 13.15 Corona Test & Cl 13.16 Radio Interference Voltage Test. |
| 14657 |
BIS, Central Laboratory (CL)
| None
| IS 14510 (1997) |
Lambda - Cyhalothrin WP - Specification |
- |
Rs.3650.00 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 3.3 Table 1 v (Acidity/Alkalinity) |
- |
|
|
|
| 3.3 Table 1 iv (Wettability) |
- |
|
|
|
| 3.2 (Description) |
- |
|
|
|
| 3.3 Table 1 i (Lamda cyhalothrin content ) |
- |
|
|
|
| 3.3 Table 1 iii (Suspensibility) |
- |
|
|
|
| 3.3 Table 1 ii (Sieving requirements material passing through 75 micron IS sieve) |
- |
|
|
|
|
- |
- excluding Cl 3.3, Table1, Sl No. I & III Lambda Cyhalothrin Content; |
| 14658 |
BIS, Northern Regional Laboratory (NRL)
| None
| IS 14756 (2017) |
Stainless steel cookware - Specification (First Revision) |
- |
- View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4.1 (Shape and Dimension,) |
- |
|
|
|
| 4.2 (Thickness) |
- |
|
|
|
| 5.1 (Workmanship And Finish) |
- |
|
|
|
| 5.2 (Workmanship And Finish) |
- |
|
|
|
| 5.3 (Workmanship And Finish) |
- |
|
|
|
| 5.4 (Workmanship And Finish) |
- |
|
|
|
| 6.2 (Mechanical Shock Test (for cladded utensils only)) |
- |
|
|
|
|
- |
- Handle test, Thermal shock test, Dry heat test, Test facility for chemical testing is not available |
| 14659 |
BIS, Central Laboratory (CL)
| None
| IS 7285 : Part 1 (2018) |
Refillable seamless steel gas cylinders - Specification: Part 1 normalized steel cylinders (Fourth Revision) |
- |
- View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 7.11 (Neck Thread) |
- |
|
|
|
| 6.7 (Foot Rings) |
- |
|
|
|
| 6.8.1 (Neck Rings) |
- |
|
|
|
| 7.3 (Surface Defects) |
- |
|
|
|
| 7.4 (Out-of-Roundness) |
- |
|
|
|
| 7.5 (Mean Diameter) |
- |
|
|
|
| 7.6 (Straightness) |
- |
|
|
|
| 7.7 (see Fig. 3) (Verticality) |
- |
|
|
|
| 7.8 (Stability) |
- |
|
|
|
| 7.10 a) (For cylinders of water capacity up to and including 20 litres = ) |
- |
|
|
|
| 7.10 b) (For cylinders of water capacity exceeding 20 litres =) |
- |
|
|
|
| 9.2.3, Fig. 4 (Hydraulic Bursting Test) |
- |
|
|
|
| 9.2.4 (Pressure Cycling Test) |
- |
|
|
|
| 10.1.3 a) & Clause 5.4 Table 3, i) ( Tensile strength (Rg) ) |
- |
|
|
|
| Clauses 6.8 and 10.3.1,Table 4 iii), Sr.no.3 (Impact Test-Cylinder Diameter Dm >140 mm i) Direction- Transverse: ii) Test temperature, in °C –20) |
- |
|
|
|
| Clauses 6.8 and 10.3.1,Table 4 iii), Sr.no.4 (Impact Test-Cylinder Diameter Dm ≤140 mmi) Direction-Longitudinal ii) Test temperature, in °C –20) |
- |
|
|
|
| 10.4.1 Table 5 ,FIG. 9 (Bend Test) |
- |
|
|
|
| 10.4.2 Table 5 (Flattening Test) |
- |
|
|
|
| 10.4.3 Table 5 (Ring-Flattening Test) |
- |
|
|
|
| 11.2 (Hydrostatic Stretch Test) |
- |
|
|
|
| 11.3 (Hardness Test) |
- |
|
|
|
| 13 (COLOUR IDENTIFICATION) |
- |
|
|
|
|
- |
- Sample size shall be minimum dia> 3mm and thickness > 0.8 mm;
excluding -; (Cl 7.4 -Out-of-roundness,Cl 7.5) - Mean diameter,(Cl 7.6)- Straightness,(Cl 7.7) -Verticality, (Cl 7.8) -Stability, (Cl 9.2.3) -Hydraulic Burst Test,(Cl 9.2.4) -Pressure Cycling Test, (Cl 10.4.2) -Flattening test, (Cl 11.2 - Hydrostatic Stretch Test, (Cl 11.4) - Leakage test |
| 14660 |
BIS, Bengaluru Branch Laboratory (BNBL)
| None
| IS 13334 : Part 2 (2014) |
Skimmed milk powder - Specification: Part 2 extra grade (First Revision) |
- |
10430/- View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Table 1 (ix) (Bacterial count (IS 5402)) |
- |
|
|
|
| Table 1 (x) (Coliform count (IS 5401 - Part 1)) |
- |
|
|
|
| Table 1 (xi) (Escherichia coli (IS 5887 - Part 1)) |
- |
|
|
|
| Table 1 (xii) (Coagulase positive Staphylococcus aureus (IS 5887 - Part 2)) |
- |
|
|
|
| Table 1 (xiii) (Salmonella (IS 5887 - Part 3)) |
- |
|
|
|
| Table 1 (xiv)(a) (Spore Count: a)Aerobic (Bacillus cereus) Type m (IS 5887 - Part 6)) |
- |
|
|
|
| Table 1 (xiv)(b) (Spore Count: b) Anaerobic (Sulfite reducing Clostridia) Type m (ISO 15213 : 2003)) |
- |
|
|
|
| Table 1 (xv) (Listeria monocytogenes (IS 14988 - Part 2 : 2001)) |
- |
|
|
|
| Table 1 (xiv)(a) (Spore Count: a)Aerobic (Bacillus cereus) Type m (IS 5887 - Part 6)) |
- |
|
|
|
| Table 1 (xiv)(b) (Spore Count: b) Anaerobic (Sulfite reducing Clostridia) Type m (ISO 15213 : 2003)) |
- |
|
|
|
| Table 1 (i) (Moisture (IS 116231or 16072)) |
- |
|
|
|
| Table 1 (ii) (Milk protein in milk solids not fat (IS 72192)) |
- |
|
|
|
| Table 1 (iii) (Milk fat (IS 117213) or Annex B) |
- |
|
|
|
| Table 1 (iv) (Insolubility index (IS 12759)) |
- |
|
|
|
| Table 1 (v) (Total ash (on dry basis), Annex B of IS 14433) |
- |
|
|
|
| Table 1 (vi) (Titratable acidity (IS 11766)) |
- |
|
|
|
| Table 1 (viii) (Scorched particles (equivalent to Disc B) (IS 13500)) |
- |
|
|
|
| Cl 4.0 (Description) |
- |
|
|
|
| Cl.5.4 (Flavour & Taste) |
- |
|
|
|
| Clause no 5.2 (freedom from extraneous matter) |
- |
|
|
|
|
- |
- Test facility not available for Lactate content. |
| 14661 |
BIS, Northern Regional Laboratory (NRL)
| None
| IS 12817 (2013) |
Stainless steel butt hinges - Specification (Second Revision) |
- |
Rs. 2400/- and testing charges as per referred Iss View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 6.2, Table 1 to 6 (Length , A -IS 12817) |
- |
|
|
|
| 6.2, Table 1 to 6 (Breadth, B-IS 12817) |
- |
|
|
|
| 6.2, Table 1 to 6 (Breadth, B1-IS 12817) |
- |
|
|
|
| 6.2, Table 1 to 6 (Breadth, B2-IS 12817) |
- |
|
|
|
| 6.2, Table 1 to 6 (Thickness of flap, C-IS 12817) |
- |
|
|
|
| 6.2, Table 1 to 6 (Dia. of Hinge pin, D-IS 12817 ) |
- |
|
|
|
| 6.2, Table 1 to 6 (Number of Knuckles- IS 12817 ) |
- |
|
|
|
| 6.2, Table 1 to 6 (Number of Screw Holes -IS 12817 ) |
- |
|
|
|
| 6.2, Table 1 to 6 (Holes for Screw Number- IS 12817 ) |
- |
|
|
|
| 7.1 (General - IS 12817 ) |
- |
|
|
|
| 7.2 (Knuckles - IS 12817 ) |
- |
|
|
|
| 7.3 (Pins- IS 12817 ) |
- |
|
|
|
| 7.4 (Screw Holes- IS 12817 ) |
- |
|
|
|
| 7.4.2 (Position of screw holes - IS 12817 ) |
- |
|
|
|
| 7.4.2, Fig 1 (The distance of the screw holes from the end of the flap - IS 12817 ) |
- |
|
|
|
| 8 (Finish - IS 12817 ) |
- |
|
|
|
|
- |
- Test facility is complete, Test facility for chemical is not available. |
| 14662 |
BIS, Central Laboratory (CL)
| None
| IS 7226 (1974) |
Specification for cold - Rolled medium, high carbon and low alloy steel strip for general engineering purposes |
- |
- View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 5 (HARDNESS TEST) |
- |
|
|
|
| 6 ( FREEDOM FROM DEFECTS) |
- |
|
|
|
| 9.1, Table 3 (i)TOLERANCE ON WIDTH) |
- |
|
|
|
| 9.1, Table 4 (ii)TOLERANCE ON THICKNESS) |
- |
|
|
|
| 9.2 ( Camber) |
- |
|
|
|
| 10 (SURFACE FINISH) |
- |
|
|
|
|
- |
- Sample size shall be minimum dia> 3mm and thickness > 0.8 mm;
excluding Except Tungsten as per table 1; |
| 14663 |
BIS, Central Laboratory (CL)
| None
| IS 14550 (1998) |
Hexaconazole, EC - Specification |
- |
Rs.1025.00 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 3.2.1 (Description) |
- |
|
|
|
| 3.2.2 (Cold Test) |
- |
|
|
|
| 3.2.3 (Flash Point (Abel)) |
- |
|
|
|
| 3.2.4 (Emulsion Stability) |
- |
|
|
|
| 3.3.2 (Acidity/Alkalinity) |
- |
|
|
|
|
- |
- excluding Cl. 3.3.1 Hexaconazole Content; |
| 14664 |
BIS, Western Regional Laboratory (WRL)
| None
| IS 253 (2014) |
Specification for common salt (Fourth Revision) |
- |
6690 View breakup
Total testing charges for common Salt = Rs 6651/-
Total testing charges for Dairy Salt = Rs 6726/-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Clause -3 for common salt 3.1 ( 3.1.2 ) Annex-2 (Moisture The material shall contain not more than 6.0 percent by mass of moisture, on as received basis, when tested according to the method given in A-2) |
- |
|
|
|
| Clause-3.1 for dairy salt (3.2.2) (3.2.2 Particle Size 99 percent by mass of the material shall pass completely through 850-micron IS Sieve [see IS 460 (Part I)].) |
- |
|
|
|
| Clause-3.2 for dairy salt (3.2.3) Annex -2 (3.2.3 Moisture The material shall contain not more than 0.5 percent by mass of moisture, on as received basis, when tested according to the methods given in A-2.) |
- |
|
|
|
| Table 1 (i) Annex -4 (Water insoluble matter, common) |
- |
|
|
|
| Table 1 (ii) Annex-5 (Chloride content (as NaCl)common) |
- |
|
|
|
| Table 1 (iii) Annex-6 ( Matter soluble in water, other than sodium chloride, common) |
- |
|
|
|
| Table 1 (iv) (Calcium (as Ca), water soluble, percent by mass, common) |
- |
|
|
|
| Table 1 (v) (Magnesium (as Mg), water soluble, percent by mass, common ) |
- |
|
|
|
| Table 1 (vi) (Sulphate as SO2 percent by mass, common) |
- |
|
|
|
| Table 1 (vii) Annex-9 (Alkalinity (as Na2CO3), common) |
- |
|
|
|
| Table 1 (vii) Annex-11 (Alkalinity (as Na2CO3), Dairy) |
- |
|
|
|
| Table 1 (ix) (Iron (as Fe), common) |
- |
|
|
|
| Table 1 (x) Annex-11 (x) Arsenic (as As), common) |
- |
|
|
|
| Table 1 (xi) Annex-12 (Copper (as Cu), common) |
- |
|
|
|
|
- |
- Test facility not available for the following: 1) Pb |
| 14665 |
BIS, Central Laboratory (CL)
| None
| IS 16232 (2014) |
Iron fortified iodized salt (Double Fortified Salt) - Food grade - Specification |
- |
11800 View breakup
For complete test facility
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 3.1 (Description - Iron fortified iodized salt (Double fortified salt) shall
be crushed crystalline solid; white or pale pink or light
grey in colour, free from contamination with clay and
other extraneous adulterants and impurities) |
- |
|
|
|
| 3.4 - Table 1 - i (Moisture - Annex A of IS 7224) |
- |
|
|
|
| 3.3 (material shall pass through 4.00 mm IS sieve) |
- |
|
|
|
| 3.4 - Table 1 - ii (Water insoluble matter, on dry basis - A-4 of IS 253
) |
- |
|
|
|
| 3.4 - Table 1 - iii (Chloride content (as NaCl), on dry basis - A-4 of IS 253) |
- |
|
|
|
| 3.4 - Table 1 - iv (Matter insoluble in dilute HCl, on dry basis - Annex G) |
- |
|
|
|
| 3.4 - Table 1 - vi (Iron content (as Fe) - Annex A) |
- |
|
|
|
| 3.4 - Table 1 - vii- a (Iodine content, Manufacturer’s level - Annex B) |
- |
|
|
|
| 3.4 - Table 1 - viii - b (pH of 5 percent aqueous solution : For other forms of iron fortification - Annex C) |
- |
|
|
|
| 3.4 - Table 1 - ix (Sulphate (as SO4) - A-8 of IS 253) |
- |
|
|
|
| 3.4 - Table 1 - x (Magnesium (as Mg), water soluble - A-7 of IS 253) |
- |
|
|
|
| 3.4 - Table 1 - xi - b (Phosphorous (as P2O5) - For other forms of iron fortification - Annex D) |
- |
|
|
|
| 3.4 - Table 1 - xii (Sodium hexa meta phosphate, on dry basis - Annex E) |
- |
|
|
|
| 3.4 - Table 1 - xi - a (Phosphorous (as P2O5) - For iron fortification through
encapsulated ferrous fumarate - Annex D) |
- |
|
|
|
| 3.4 - Table 1 - v (Matter soluble in water other than sodium chloride, on dry basis - A-6 of IS 253) |
- |
|
|
|
|
- |
- 500 gm x 3
excluding 1-Phosphorous (as P2O5), 2-Sodium hexa meta phosphate, 3-Iron; |
| 14666 |
BIS, Southern Regional Laboratory (SRL)
| None
| IS 281 (2009) |
Mild steel sliding door bolts for use with padlocks - Specification (Fourth Revision) |
- |
- View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4 (SIZES) |
- |
|
|
|
| 6-Table 1 (DIMENSIONS AND TOLERANCES-A) |
- |
|
|
|
| 6 (DIMENSIONS AND TOLERANCES-A) |
- |
|
|
|
| 6-Table 1 (DIMENSIONS AND TOLERANCES-B) |
- |
|
|
|
| 6-Table 1 (DIMENSIONS AND TOLERANCES-T) |
- |
|
|
|
| 6-Table 1 (DIMENSIONS AND TOLERANCES-C) |
- |
|
|
|
| 6-Table 1 (DIMENSIONS AND TOLERANCES-D) |
- |
|
|
|
| 6-Table 1 (DIMENSIONS AND TOLERANCES-E) |
- |
|
|
|
| 6-Table 1 (DIMENSIONS AND TOLERANCES-F) |
- |
|
|
|
| 6-Table 1 (DIMENSIONS AND TOLERANCES-G) |
- |
|
|
|
| 6-Table 1 (DIMENSIONS AND TOLERANCES-H) |
- |
|
|
|
| 6-Table 1 (DIMENSIONS AND TOLERANCES-J) |
- |
|
|
|
| 6-Table 1 (DIMENSIONS AND TOLERANCES-No. of Rivets on bolts plates) |
- |
|
|
|
| 6-Table 1 (DIMENSIONS AND TOLERANCES-No. of Rivets on Socket) |
- |
|
|
|
| 6-Table 1 (DIMENSIONS AND TOLERANCES-No. of Screw holes on bolt) |
- |
|
|
|
| 6-Table 1 (DIMENSIONS AND TOLERANCES-No. of Screw holes on Staple) |
- |
|
|
|
| 6-Table 1 (DIMENSIONS AND TOLERANCES-no. of 8m Sqire Holes for carriage bolts for plate and sockets) |
- |
|
|
|
| 6-Table 1 (DIMENSIONS AND TOLERANCES-no. of 8m Sqire Holes for carriage bolts for Staple) |
- |
|
|
|
| 7.1 (MANUFACTURE-General) |
- |
|
|
|
| 7.1 (MANUFACTURE-General) |
- |
|
|
|
| 7.2 (MANUFACTURE-Sliding Door Bolts, Plate Type) |
- |
|
|
|
| 7.3 (MANUFACTURE-Sliding Bolts, Clip or Bolt Type) |
- |
|
|
|
| 7.2 (MANUFACTURE-Sliding Door Bolts, Plate Type) |
- |
|
|
|
| 3 (TYPES) |
- |
|
|
|
| 7.3 (MANUFACTURE-Sliding Bolts, Clip or Bolt Type) |
- |
|
|
|
| 7.3 (MANUFACTURE-Sliding Bolts, Clip or Bolt Type) |
- |
|
|
|
| 7.3 (MANUFACTURE-Sliding Bolts, Clip or Bolt Type) |
- |
|
|
|
| 7.2 (MANUFACTURE-Sliding Door Bolts, Plate Type) |
- |
|
|
|
| 7.2 (MANUFACTURE-Sliding Door Bolts, Plate Type) |
- |
|
|
|
| 7.2 (MANUFACTURE-Sliding Door Bolts, Plate Type) |
- |
|
|
|
|
- |
- " 3 pcs
Excluding except cupping, strain ageing test and chemical requirements |
| 14667 |
BIS, Southern Regional Laboratory (SRL)
| None
| IS 7887 (1992) |
Mild steel wire rod for general engineering purposes - Specification (First Revision) |
- |
Rs.7200/- View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl 8 (Workmanship) |
- |
|
|
|
| Cl 9 (Nominal Diameter & Out Of Shape) |
- |
|
|
|
| 6.1 (Carbon %) |
- |
|
|
|
| 6.1 (Manganese %) |
- |
|
|
|
| 6.1 (Phosphorus %) |
- |
|
|
|
| 6.1 (Sulphur %) |
- |
|
|
|
| 6.1 (Silicon %) |
- |
|
|
|
| 6.1 ( Aluminium %) |
- |
|
|
|
| Table 1 Note 3 (Copper) |
- |
|
|
|
| Amendment 1 (Niobium) |
- |
|
|
|
| Amendment 1 (Vanadium) |
- |
|
|
|
| Amendment 1 (Titanium) |
- |
|
|
|
| Amendment 1 (Micro Alloying Element (Nb+V+Ti)) |
- |
|
|
|
|
- |
- " 1.5 m + 25 g Chemical Facility is available Quantity: 5 Pieces of 5cm X 5cm
Excluding |
| 14668 |
BIS, Central Laboratory (CL)
| None
| IS 15160 (2002) |
Pretilachlor emulsifiable concentrate - specification |
- |
Rs.2450.00 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 3.2.1 (Description) |
- |
|
|
|
| 3.2.2 (Cold Test) |
- |
|
|
|
| 3.2.3 (Flash Point (Abel)) |
- |
|
|
|
| 3.2.4 (Emulsion Stability) |
- |
|
|
|
| 3.3.1 (Pretilachlor content) |
- |
|
|
|
| 3.3.2 (Acidity) |
- |
|
|
|
|
- |
- - |
| 14669 |
BIS, Central Laboratory (CL)
| None
| IS 10325 (2000) |
Square tins - 15 kg/litre for ghee, vanaspati, edible oils and bakery shortenings - Specification (Second Revision) |
- |
3700 View breakup
Rs.3700/- (excluding Solder testing) and Rs.1500/- for solder testing.
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4.1 (Dimensions and Tolerances) |
- |
|
|
|
| 4.1 (Dimensions and Tolerances) |
- |
|
|
|
| 4.1 (Dimensions and Tolerances) |
- |
|
|
|
| 4.2.2 (Handle) |
- |
|
|
|
| 4.3.1 (Manufacture) |
- |
|
|
|
| 4.3.2 (Manufacture) |
- |
|
|
|
| 4.3.3 (Manufacture) |
- |
|
|
|
| 4.3.4 (Manufacture) |
- |
|
|
|
| 4.3.5 (Handle) |
- |
|
|
|
| 4.3.5 (Handle) |
- |
|
|
|
| 4.3.5 (Handle) |
- |
|
|
|
| 4.3.5 (Handle) |
- |
|
|
|
| 5.1 (Air-Pressure Test) |
- |
|
|
|
| 5.2 (Handle Pull Test) |
- |
|
|
|
| 5.3 (Hydraulic Pressure Test) |
- |
|
|
|
| 4.2.2 (Handle) |
- |
|
|
|
|
- |
- "Test facility for base metal and tin coating as per IS 1327. Sample size 5x5 cmm thickness > 3mm.
Test facility complete for mechanical; "
excluding Test facility for base metal and tin coating as per IS 1327 available. for material thickness < 0.8 mm only C & S can be tested.; |
| 14670 |
BIS, Central Laboratory (CL)
| None
| IS 2403 (2014) |
Short - Pitch transmission precision roller and bush chains, attachments and associated chain sprockets (Third Revision) |
- |
- View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 3.3 Table-1,2 (Dimensions- Pitch- p) |
- |
|
|
|
| 3.3 Table-1,2 (Dimensions- Roller diameter- d1) |
- |
|
|
|
| 3.3 Table-1,2 (Dimensions- Width between
inner plates- b1) |
- |
|
|
|
| 3.3 Table-1,2 (Dimensions- Bearing pin body diameter- d2) |
- |
|
|
|
| 3.3 Table-1,2 (Dimensions-Bush bore-d3) |
- |
|
|
|
| 3.3 Table-1,2 (Dimensions- Chain path depth- h1) |
- |
|
|
|
| 3.3 Table-1,2 (Dimensions-Inner plate depth- h2) |
- |
|
|
|
| 3.3 Table-1,2 (Dimensions-Outer plate depth- h3) |
- |
|
|
|
| 3.3 Table-1,2 (Dimensions- Cranked link dimensions- l1) |
- |
|
|
|
| 3.3 Table-1,2 (Dimensions- Cranked link dimensions- l2) |
- |
|
|
|
| 3.3 Table-1,2 (Dimensions- Cranked link dimensions- c) |
- |
|
|
|
| 3.3 Table-1,2 (Dimensions- Transverse pitch- pt) |
- |
|
|
|
| 3.3 Table-1,2 (Dimensions- Width over inner link- b2) |
- |
|
|
|
| 3.3 Table-1,2 (Dimensions- Width between outer plates- b3) |
- |
|
|
|
| 3.3 Table-1,2 (Dimensions- Width over bearing pins- b4) |
- |
|
|
|
| 3.3 Table-1,2 (Dimensions- Width over bearing pins- b5) |
- |
|
|
|
| 3.3 Table-1,2 (Dimensions- Width over bearing pins- b6) |
- |
|
|
|
| 3.3 Table-1,2 (Dimensions- Additional width for joint fastener- b7) |
- |
|
|
|
| 3.4.2 (Tensile Test) |
- |
|
|
|
|
- |
- excluding -; i)Dynamic Testing(CL 3.4.5) |