Search by IS Number
Reset
15633 Results
S.No. Lab Name Osl Code Indian Standard No. Product Grade / Type / Size / Designation etc. Testing Charges (Excl. Of Taxes) Validity Date Remark
14671 BIS, Central Laboratory (CL) None IS 1626 : Part 2 (1994) Asbestos cement building pipes and pipe fittings, gutters and gutter fittings and roofing fittings: Part 2 gutter and gutter fittings) (Second Revision) - 1500 View breakup
-
- -
Excluding -; impermeability test
14672 BIS, Central Laboratory (CL) None IS 1592 (2003) Asbestos cement pressure pipes and joints - Specification (Fourth Revision) - 1950 View breakup
Rs. 1950/- + testing charges as per referred ISS (excluding Physical and Mechanical characteristics).
- -
-
14673 BIS, Eastern Regional Laboratory (ERL) None IS 1785 : Part 1 (1983) Specification for plain hard - Drawn steel wire for prestressed concrete: Part 1 cold drawn stress - Relieved wire (Second Revision) For all sizes except test mentioned in remarks Rs. 27300.00 (Complete testing charges) Rs. 9300.00 (F View breakup
-
- -
except stress relaxation test
14674 Ace Test Labs & Metrology Pvt. Ltd., Sonipat 9162826 IS 16046 : Part 1 (2018) Secondary Cells and Batteries Containing Alkaline or Other Non-Acid Electrolytes ” Safety Requirements for Portable Sealed Secondary Cells and for Batteries Made from Them for Use in Portable Applications Part 1 Nickel Systems ( Second Revision ) - 141000 View breakup
Rs.121000/- for Nickel Battery, Rs.141000/- for Nickel Cells (10% discount for BIS)under CRS
14 Nov, 2027 -
Included w.e.f. 26.04.2019 Upto 30 V and 10 A only
14675 BIS, Western Regional Laboratory (WRL) None IS 903 (1993) Specification for Fire Hose Delivery Couplings, Branch Pipe, Nozzles And Nozzle Spanner - Specificaion - Rs 3600/ View breakup
-
- -
Test facilities are not available for the following: 1 Thread gauges
14676 BIS, Central Laboratory (CL) None IS 1269 : Part 2 (1997) Legal metrology - Material measures of length: Part 2 steel tape measures - 2100 View breakup
-
- -
Excluding -; Cl 4 - Materials, Cl 8 - Accuracy Classes & Max. Permissible Error
14677 BIS, Central Laboratory (CL) None IS 14709 (1999) N - Butyl acrylate - Specification - - View breakup
-
- -
-
14678 BIS, Western Regional Laboratory (WRL) None IS 1239 : Part 1 (2004) Steel tubes, tubulars and other wrought steel fittings - Specification: Part 1 steel tubes (Sixth Revision) - Rs. 9200/- Excluding test on joints View breakup
-
- -
Test facilities are not available for the following: 1. Micro-alloying elements like Nb. V or Ti, Nitrogen, Al,Cu 2. Bending test
14679 BIS, Central Laboratory (CL) None IS 398 : Part 2 (1996) Aluminium conductors for overhead transmission purposes - Specification: Part 2 aluminium conuuctors, galvanized steel - Reinforced (Third Revision) - - View breakup
-
- -
Complete upto 80 sqmm, Above 80 sq. mm. TF not available for Stress-strain test, Surface conditioning test, ultimate breaking load on stranded conductor
14680 BIS, Central Laboratory (CL) None IS 12592 (2002) Precast concrete manhole cover and frame - Specification (First Revision) - 1809 View breakup
-
- -
Complete
14681 Ace Test Labs & Metrology Pvt. Ltd., Sonipat 9162826 IS 16102 : Part 1 (2012) Self - Ballasted led lamps for general lighting services: Part 1 safety requirements - 51000 View breakup
Rs.51000/- (10% discount for BIS)
14 Nov, 2027 -
Only for IP(0-4)(5-6) Restricted for B22d , and E14 , E 27 ( Included w.e.f. 27.08.2019) Upto 30 V and 10 A only
14682 BIS, Western Regional Laboratory (WRL) None IS 2002 (2009) Steel plate for pressure vessel for intermediate and high temperature service including boilers (Third Revision) - 8500 View breakup
-
- -
Test facilities are not available for the following: 1. Al, N, Cu, Mn, Cr, Mo, V, Ni 3. Homogeneity test 3. Ultrasonic test, ( cl 15 )
14683 BIS, Central Laboratory (CL) None IS 1038 (1983) Specification For Steel Doors, Windows And Ventilators - 3000 View breakup
-
- -
-
14684 BIS, Central Laboratory (CL) None IS 12427 (2001) Fasteners - Threaded steel fasteners - Hexagon head transmission tower bolts - Specification (First Revision) - 3750 View breakup
-
- -
Excluding -; Cl 6 - Mechanical Properties as per IS 1367-3 (Except Hardness & Impact Test), Cl 6.2 - Shear Strength
14685 BIS, Central Laboratory (CL) None IS 7452 (1990) Hot rolled steel sections for doors, windows and ventilators - Specification - Rs 1800/- View breakup
-
- -
Sample size shall be minimum dia> 3mm and thickness > 0.8 mm;
14686 BIS, Central Laboratory (CL) None IS 4454 : Part 2 (2001) Steel wire for mechanical springs - Specification february 2001: Part 2 oil hardened and tempered steel wire (Second Revision) - - View breakup
-
- -
Sample size shall be minimum dia> 3mm and thickness > 0.8 mm;
14687 BIS, Central Laboratory (CL) None IS 398 : Part 1 (1996) Aluminium conductors for overhead transmission purposes - Specification: Part 1 aluminium stranded conductors (Third Revision) - Rs.1600/- for 7 strands, Rs.3750/- for 19 strands View breakup
-
- -
-
14688 BIS, Central Laboratory (CL) None IS 2721 (2003) Galvanized steel chain link fence fabric - Specification (Second Revision) - 6910 View breakup
-
- -
Sample size shall be minimum dia> 3mm and thickness > 0.8 mm;
14689 CIPET, Hyderabad 6111634 IS 710 (2010) Marine plywood - Specification (Second Revision) - 20050 View breakup
Rs.19675/-
23 Feb, 2027 -
Testing charges has been fixed for a period of two years w.e.f. 29.01.2019 i.e. up to 28.01.2021.
14690 BIS, Eastern Regional Laboratory (ERL) None IS 210 (2009) Grey iron castings - Specification (First Revision) For all grades except tests mentioned in remarks Rs.2700.00 View breakup
-
- -
Chem: only available for Phosphorous as per Cl. 6.1) Mech- Excluding hydrostatic test and transverse test. Note: For Hardness test, provide sample greater than 10 mm thickness. If separate test specimens are not sent for Tensile and Hardness, the hardness will be conducted on the same test bar/specimen.
14691 IDMA LABORATORIES LIMITED, PANCHKULA 9123236 IS 2785 (1979) Specification for natural cheese (Hard Variety), processed cheese, processed cheese spread and soft cheese (First Revision) - 2000 View breakup
-
31 Dec, 2026 -
-
14692 BIS, Patna Branch Laboratory (PBL) None IS 8041 (1990) Rapid hardening portland cement - Specific4tion (Second Revision) - - View breakup
-
- -
All test facilities are available as per the IS
14693 BIS, Eastern Regional Laboratory (ERL) None IS 12330 (1988) Specificatioon for sulphate resisting Portland cement - Rs.12900/- View breakup
-
- -
Facility not available for transverse strength test(Optional)
14694 BIS, Patna Branch Laboratory (PBL) None IS 15911 (2010) Structural steel (Ordinary Quality) - Specification - Rs 6750/- For elements other than Table-1: Rs 1004/- pe View breakup
-
- -
All test facilities are available as per the IS except tests for Chromium, Molybdenum, Vanadium, Nickel, Copper, Niobium, Boron, Titanium, Aluminium and Tungsten (Clause 8.2)
14695 BIS, Central Laboratory (CL) None IS 9537 : Part 2 (1981) Specification for conduits for electrical installations: Part 2 rigid steel conduits - Rs 2100/- View breakup
-
- -
-
14696 BIS, Patna Branch Laboratory (PBL) None IS 10124 : Part 2 (2009) Fabricated pvc - U fittings for potable water supplies - Specification: Part 2 specific requirements for sockets (Second Revision) - Rs.1800/ View breakup
-
- -
All test facilities are available as per the IS except- i. Short Term Hydrostatic Test (Clause 6.2) ii. Effect on Water (Clause 6.3)
14697 BIS, Eastern Regional Laboratory (ERL) None IS 1079 (2017) Hot rolled carbon steel sheet, plate and strip - Specification (Seventh Revision) For all grades except tests mentioned in remarks - View breakup
-
- -
-
14698 Ace Test Labs & Metrology Pvt. Ltd., Sonipat 9162826 IS 16242 : Part 1 (2014) Uninterruptible power systems (UPS): Part 1 general and safety requirements for UPS - 108000 View breakup
Rs.108000/- (10% discount for BIS)
14 Nov, 2027 -
Only for IP(0-4)(5-6) For UPS/Inverter up to 5KVA), UPS < =10 KVA Excluding: Cl. 4.5/1.5 of RD Components - Cl. 5.6/2.8 of RD Safety Interlocks Cl. 2.10.5.4 & Annex U of RD Semiconductor Devices Cl.2.10.6 PCB material, Cl. 2.10.5.11 Insulation in wound components, CL.7.6 & Annex-M Ventilation of battery Compartment, Annex-L.5 Non linear Loads, Annex-I.5 Solid state backfeed protection Annex-H /Table Protection against Ingress of foreign objects
14699 BIS, Central Laboratory (CL) None IS 4505 (2015) Sodium formaldehyde sulphoxylate - Specification (First Revision) - - View breakup
-
- -
-
14700 BIS, Eastern Regional Laboratory (ERL) None IS 1989 : Part 1 (1986) Specification for leather safety boots and shoes: Part 1 for miners (Fourth Revision) For all sizes except test mentioned in remarks Rs 5100/- for safety boots, Rs.4500/- safety shoes View breakup
-
- -
Mech- 2 pairs, Chem-2 pairs