| 14731 |
BIS, Southern Regional Laboratory (SRL)
| None
| IS 12600 (1989) |
Portland cement, low heat - specification |
- |
- View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 6.1 (Fineness 4031 Part 2) |
- |
|
|
|
| 6.2.1 (Expansion by Le Chatelier- 4031 Part 3) |
- |
|
|
|
| 6.2.1 (Expansion by Autoclave- 4031 Part 3) |
- |
|
|
|
| 6.3 a) (Setting Time Initial- 4031 Part 5) |
- |
|
|
|
| 6.3 b) (Setting Time Final- 4031 Part 5) |
- |
|
|
|
| 6.3 a) (Setting Time Initial- 4031 Part 5) |
- |
|
|
|
| 6.3 b) (Setting Time Final- 4031 Part 5) |
- |
|
|
|
| 6.3 a) (Setting Time Initial- 4031 Part 5) |
- |
|
|
|
| 6.3 b) (Setting Time Final- 4031 Part 5) |
- |
|
|
|
| 6.3 a) (Setting Time Initial- 4031 Part 5) |
- |
|
|
|
| 6.3 b) (Setting Time Final- 4031 Part 5) |
- |
|
|
|
| 6.3 a) (Setting Time Initial- 4031 Part 5) |
- |
|
|
|
| 6.3 b) (Setting Time Final- 4031 Part 5) |
- |
|
|
|
| 6.4 a) (Compressive Strength At 72 hrs ± 1 hr - IS 4031 Part 6) |
- |
|
|
|
| 6.4 b) (Compressive Strength At 168 hrs ± 2 hr - IS 4031 Part 6) |
- |
|
|
|
| 6.4 c) (Compressive Strength At 672 hrs ± 4 hr - IS 4031 Part 6) |
- |
|
|
|
| 6.4 a) (Compressive Strength At 72 hrs ± 1 hr - IS 4031 Part 6) |
- |
|
|
|
| 6.4 b) (Compressive Strength At 168 hrs ± 2 hr - IS 4031 Part 6) |
- |
|
|
|
| 6.4 c) (Compressive Strength At 672 hrs ± 4 hr - IS 4031 Part 6) |
- |
|
|
|
| 6.4 a) (Compressive Strength At 72 hrs ± 1 hr - IS 4031 Part 6) |
- |
|
|
|
| 6.4 b) (Compressive Strength At 168 hrs ± 2 hr - IS 4031 Part 6) |
- |
|
|
|
| 6.4 c) (Compressive Strength At 672 hrs ± 4 hr - IS 4031 Part 6) |
- |
|
|
|
| 6.4 a) (Compressive Strength At 72 hrs ± 1 hr - IS 4031 Part 6) |
- |
|
|
|
| 6.4 b) (Compressive Strength At 168 hrs ± 2 hr - IS 4031 Part 6) |
- |
|
|
|
| 6.4 c) (Compressive Strength At 672 hrs ± 4 hr - IS 4031 Part 6) |
- |
|
|
|
| 6.4 a) (Compressive Strength At 72 hrs ± 1 hr - IS 4031 Part 6) |
- |
|
|
|
| 6.4 b) (Compressive Strength At 168 hrs ± 2 hr - IS 4031 Part 6) |
- |
|
|
|
| 6.4 c) (Compressive Strength At 672 hrs ± 4 hr - IS 4031 Part 6) |
- |
|
|
|
| 6.4 a) (Compressive Strength At 72 hrs ± 1 hr - IS 4031 Part 6) |
- |
|
|
|
| 6.4 b) (Compressive Strength At 168 hrs ± 2 hr - IS 4031 Part 6) |
- |
|
|
|
| 6.4 c) (Compressive Strength At 672 hrs ± 4 hr - IS 4031 Part 6) |
- |
|
|
|
| 6.4 a) (Compressive Strength At 72 hrs ± 1 hr - IS 4031 Part 6) |
- |
|
|
|
| 6.4 b) (Compressive Strength At 168 hrs ± 2 hr - IS 4031 Part 6) |
- |
|
|
|
| 6.4 c) (Compressive Strength At 672 hrs ± 4 hr - IS 4031 Part 6) |
- |
|
|
|
|
- |
- " 8Kg+1kg
Excluding Excl Heat of Hydration |
| 14732 |
BIS, Central Laboratory (CL)
| None
| IS 7809 : Part 3 : Sec 1 (1986) |
Specification for pressure sensitive adhesive insulating tapes for electrical purposes: Part 3 requirements or individual materials: Sec 1 plasticized polyvinylchloride tapes with non - Thermosetting adhesive (First Revision) |
- |
- View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 3.1 (Marking, Cl.9 of IS 7809 (Part 1):1975) |
- |
|
|
|
| 3.1 (Marking, Cl.9 of IS 7809 (Part 1):1975) |
- |
|
|
|
| 3.1 (Marking, Cl.9 of IS 7809 (Part 1):1975) |
- |
|
|
|
| 3.1 (Marking, Cl.9 of IS 7809 (Part 1):1975) |
- |
|
|
|
| 3.1 (Marking, Cl.9 of IS 7809 (Part 1):1975) |
- |
|
|
|
| 3.1 (Marking, Cl.9 of IS 7809 (Part 1):1975) |
- |
|
|
|
| 3.1 (Marking, Cl.9 of IS 7809 (Part 1):1975) |
- |
|
|
|
| 3.1 (Marking, Cl.9 of IS 7809 (Part 1):1975) |
- |
|
|
|
| 3.1 (Marking, Cl.9 of IS 7809 (Part 1):1975) |
- |
|
|
|
| 2.1.1 (Type and Desiganation) |
- |
|
|
|
| 2.1.2 (Type and Desiganation) |
- |
|
|
|
| 3.1 (General Requirments,as per IS 7809 (Part 1 ) :1975 ) |
- |
|
|
|
| 3.2 (General Requirments,as per IS 7809 (Part 1 ) :1975 ) |
- |
|
|
|
| 3.3 (General Requirments,as per IS 7809 (Part 1 ) :1975 ) |
- |
|
|
|
| 3.4 (General Requirments,as per IS 7809 (Part 1 ) :1975 ) |
- |
|
|
|
| 4.1 (Performance Requirments) |
- |
|
|
|
| 4.2 (Performance Requirments) |
- |
|
|
|
| 4.3 (Performance Requirments) |
- |
|
|
|
| 4.4 (Performance Requirments) |
- |
|
|
|
| 4.5 (Performance Requirments) |
- |
|
|
|
| 4.6 (Flammability ,Cl 6 of IS 7809 (Part 2): 1977) |
- |
|
|
|
| 4.6 (Flammability ,Cl 6 of IS 7809 (Part 2): 1977) |
- |
|
|
|
| 4.6 (Flammability ,Cl 6 of IS 7809 (Part 2): 1977) |
- |
|
|
|
| 4.7 (Electrolytic corrosion) |
- |
|
|
|
| 4.8 (Stability to accelerated ageing ) |
- |
|
|
|
| 4.9 (Insulation resistance test) |
- |
|
|
|
| 3.1 ( Minimum Storage Life Cl. 7.1 of IS 7809(Part 1) :1975) |
- |
|
|
|
| 3.1 (Appearance) |
- |
|
|
|
| 3.1 (Minimum Storage Life ,Dimensions , Cl. 7.1 of IS 7809(Part 1) :1975) |
- |
|
|
|
| 3.1 (Minimum Storage Life ,Dimensions , Cl. 7.1 of IS 7809(Part 1) :1975) |
- |
|
|
|
| 3.1 (Minimum Storage Life ,Dimensions , Cl. 7.1 of IS 7809(Part 1) :1975) |
- |
|
|
|
| 3.1 (Minimum Storage Life ,Dimensions , Cl. 7.1 of IS 7809(Part 1) :1975) |
- |
|
|
|
| 3.1 (Marking, Cl.9 of IS 7809 (Part 1):1975) |
- |
|
|
|
| Cl. 4.1 of IS 7809-1-1975 (Appearance) |
- |
|
|
|
| Cl. 5.1 of IS 7809-1-1975 (Freedom from defects) |
- |
|
|
|
|
- |
- - |
| 14733 |
BIS, Southern Regional Laboratory (SRL)
| None
| IS 12337 (1988) |
Specification for manually operated fertilizer broadcaster |
- |
Rs 600/- View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4.1 (Constructional Requirements- Hopper) |
- |
|
|
|
| 4.1.1 (Constructional Requirements- Hopper) |
- |
|
|
|
| 4.2 (Constructional Requirements- Spreading Disc) |
- |
|
|
|
| 4.3 (Constructional Requirements- Feed Control Mechanism) |
- |
|
|
|
| 4.4 (Constructional Requirements- Agitator) |
- |
|
|
|
| 4.5 (Constructional Requirements- Gear Box and Gears) |
- |
|
|
|
| 4.6 (Constructional Requirements- Crank) |
- |
|
|
|
| 4.7 (Constructional Requirements- Straps) |
- |
|
|
|
| 4.7.1 (Constructional Requirements- Straps (Strap Drop Test)) |
- |
|
|
|
| 4.7 (Constructional Requirements- Straps (cushion width)) |
- |
|
|
|
| 4.7 (Constructional Requirements- Straps (cushion thickness)) |
- |
|
|
|
| 4.7.1 (Constructional Requirements- Straps (Strap Drop Test)) |
- |
|
|
|
| 4.8 (Constructional Requirements- Bearings) |
- |
|
|
|
| 4.9 (Constructional Requirements- Total Mass) |
- |
|
|
|
| 4.10. (Constructional Requirements) |
- |
|
|
|
| 5 (Capacity) |
- |
|
|
|
| 6.1 (Workmanship and Finish) |
- |
|
|
|
| 6.2 (Workmanship and Finish) |
- |
|
|
|
|
- |
- " 1 No.+ 15 kg of Fertilizer
excluding chemical tests |
| 14734 |
BIS, Central Laboratory (CL)
| None
| IS 374 (2019) |
Specification for electric ceiling type fans and regulators (Third Revision) |
- |
- View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 7 (Classification (as per Cl.6 of IS 302-2-80 :2017)) |
- |
|
|
|
| 7 (Classification (as per Cl.6 of IS 302-2-80 :2017)) |
- |
|
|
|
| 7 (Classification (as per Cl.6 of IS 302-2-80 :2017)) |
- |
|
|
|
| 7 (Classification (as per Cl.6 of IS 302-2-80 :2017)) |
- |
|
|
|
| 8.1 (Marking (as per Cl. 7 of IS 302-2-80:2017)) |
- |
|
|
|
| 8.1,a (Marking ) |
- |
|
|
|
| 8.1,b (Marking ) |
- |
|
|
|
| 8.1,c (Marking ) |
- |
|
|
|
| 8.1,d (Marking ) |
- |
|
|
|
| 8.1,e (Marking ) |
- |
|
|
|
| 8.1,f (Marking ) |
- |
|
|
|
| 8.1,g (Marking ) |
- |
|
|
|
| 8.2 (Marking ) |
- |
|
|
|
| 8.3,a (Marking ) |
- |
|
|
|
| 8.3,b (Marking ) |
- |
|
|
|
| 8.3,c (Marking ) |
- |
|
|
|
| 8.3,d (Marking ) |
- |
|
|
|
| 8.3,e (Marking ) |
- |
|
|
|
| 8.4 (Marking ) |
- |
|
|
|
| 8 (Marking (as per Cl. 7.1 of IS 302-2-80:2017)) |
- |
|
|
|
| 8 (Marking (as per Cl. 7 of IS 302-2-80:2017, Cl.7.1 (f) of IS 302-1:2008)) |
- |
|
|
|
| 8 (Marking (as per Cl. 7 of IS 302-2-80:2017, Cl.7.1(g) of IS 302-1:2008)) |
- |
|
|
|
| 8 (Marking (as per Cl.7.12.1(a) of IS 302-2-80:2017)) |
- |
|
|
|
| 6.2 (Rating) |
- |
|
|
|
| 9 (Protection against access to live parts (as per Cl.8 of IS 302-2-80 :2017)) |
- |
|
|
|
| 9 (Power Input & current (as per Cl.10 of IS 302-2-80 :2017)) |
- |
|
|
|
| 9 ( Heating (as per Cl.11 of IS 302-2-80 :2017)) |
- |
|
|
|
| 9 ( Heating (as per Cl.11 of IS 302-2-80 :2017)) |
- |
|
|
|
| 9 ( Heating (as per Cl.11 of IS 302-2-80 :2017)) |
- |
|
|
|
| 9 ( Heating (as per Cl.11 of IS 302-2-80 :2017)) |
- |
|
|
|
| 9 (Leakage current and Electric strength at operating temperature (as per Cl.13 of IS 302-2-80 :2017)) |
- |
|
|
|
| 9 (Leakage current and Electric strength at operating temperature (as per Cl.13 of IS 302-2-80 :2017)) |
- |
|
|
|
| 9 (Moisture Resistance (After Humidity test) (as per Cl.15 & Cl.16 of IS 302-2-80 :2017) ) |
- |
|
|
|
| 9 (Moisture Resistance (After Humidity test) (as per Cl.15 & Cl.16 of IS 302-2-80 :2017) ) |
- |
|
|
|
| 9 (Mechanical strength (as per Cl.21 of IS 302-2-80 :2017 and Cl.21.1 of IS 302-2:2008)) |
- |
|
|
|
| 9 (Mechanical strength (as per Cl.21 of IS 302-2-80 :2017 and Cl.21.1 of IS 302-2:2008)) |
- |
|
|
|
| 9 (Mechanical strength (as per Cl.21.102 of IS 302-2-80 :2017)) |
- |
|
|
|
| 9 (Mechanical strength (as per Cl.21.102 of IS 302-2-80 :2017)) |
- |
|
|
|
| 9 (Construction (as per Cl.22.101 of IS 302-2-80 :2017)) |
- |
|
|
|
| 9 (Internal wiring (as per Cl.23 of IS 302-2-80 :2017 and Cl.23 of IS 302-1:2008)) |
- |
|
|
|
| 9 (Internal wiring (as per Cl.23 of IS 302-2-80 :2017 and Cl.23 of IS 302-1:2008)) |
- |
|
|
|
| 9 (Internal wiring (as per Cl.23 of IS 302-2-80 :2017 and Cl.23 of IS 302-1:2008)) |
- |
|
|
|
| 9 (Components (as per Cl.24.103 of IS 302-2-80 :2017)) |
- |
|
|
|
| 9 (Components (as per Cl.24.104 of IS 302-2-80 :2017)) |
- |
|
|
|
| 9 (Supply Connection and External Flexible cords (as per Cl.25 of IS 302-2-80 :2017)) |
- |
|
|
|
| 9 (Terminals for External conductors (as per Cl.26 of IS 302-2-80 :2017)) |
- |
|
|
|
| 9 (Provision for earthing (as per Cl.27 of IS 302-2-80 :2017)) |
- |
|
|
|
| 9 (Provision for earthing (as per Cl.27 of IS 302-2-80 :2017)) |
- |
|
|
|
| 9 (Provision for earthing (as per Cl.27 of IS 302-2-80 :2017)) |
- |
|
|
|
| 9 (Screw and connections (as per Cl.28 of IS 302-2-80 :2017)) |
- |
|
|
|
| 9 (Clearances, creepage distances and solid insulation (as per Cl.29 of IS 302-2-80 :2017)) |
- |
|
|
|
| 9 (Clearances, creepage distances and solid insulation (as per Cl.29 of IS 302-2-80 :2017)) |
- |
|
|
|
| 9 (Resistance to fire (Glow wire Test) (as per Cl.30 of IS 302-2-80 :2017)) |
- |
|
|
|
| 9 (Resistance to rusting (as per Cl.31 of IS 302-2-80 :2017)) |
- |
|
|
|
| 10.1 (Speed Regulators) |
- |
|
|
|
| 10.2 (Speed Regulators) |
- |
|
|
|
| 10.2 (Speed Regulators) |
- |
|
|
|
| 10.2 (Speed Regulators) |
- |
|
|
|
| 10.4 (Speed Regulators) |
- |
|
|
|
| 10.5 (Speed Regulators) |
- |
|
|
|
| 10.6 (Speed Regulators) |
- |
|
|
|
| 11.1 (Starting) |
- |
|
|
|
| 12 (Interchangeability) |
- |
|
|
|
| 14.4 (Measurement of Speed of the Fan ) |
- |
|
|
|
| 14.4 (Measurement of Speed of the Fan ) |
- |
|
|
|
| 14.5 (Measurement of Power factor and Power Input) |
- |
|
|
|
| 14.5 (Measurement of Power factor and Power Input) |
- |
|
|
|
| 16 (Endurance Test) |
- |
|
|
|
| 16 (Endurance Test) |
- |
|
|
|
| 9 (Resistance to fire (Glow wire Test) (as per Cl.30 of IS 302-2-80 :2017)) |
- |
|
|
|
| 16 (Endurance Test) |
- |
|
|
|
| (Cl. 17 of IS 302-2-80 :2017) (Overload protection of transformers and associated circuits) |
- |
|
|
|
| (Cl.4.4 of IS 374: 2019) (Bearings) |
- |
|
|
|
| (Cl. 4.5 of IS 374: 2019) (Brushless DC Motor) |
- |
|
|
|
| (Cl.4.6 of IS 374: 2019) (Enclosure) |
- |
|
|
|
| (Cl. 7.6 of IS 302 Part 1) (Marking and Instructions) |
- |
|
|
|
| Cl. 7.8 of IS 302-2-80 :2017 (MARKING AND INSTRUCTIONS) |
- |
|
|
|
| (Cl. 7.12 of IS 302-2-80 :2017) (Marking and Instructions) |
- |
|
|
|
| (Cl. 7.12.1 of IS 302-2-80 :2017) (Marking and Instructions) |
- |
|
|
|
| (Cl. 7.12.5 of IS 302-1: 2008) (Marking and Instructions) |
- |
|
|
|
| (Cl. 7.12.5 of IS 302-1: 2008) (Marking and Instructions) |
- |
|
|
|
| (Cl. 7.12.5 of IS 302-1: 2008) (Marking and Instructions) |
- |
|
|
|
| (Cl. 7.12.7 of IS 302-1: 2008 (Marking and Instructions) |
- |
|
|
|
| (Cl. 7.13 of IS 302-1: 2008) (Marking and Instructions) |
- |
|
|
|
| (Cl. 7.14 of IS 302-1: 2008) (Marking and Instructions) |
- |
|
|
|
| (Cl. 10.1 of IS 374: 2019) (SPEED REGULATORS) |
- |
|
|
|
| (Cl. 10.3 of IS 374: 2019) (SPEED REGULATORS) |
- |
|
|
|
| (Cl. 10.4 of IS 374: 2019) (SPEED REGULATORS) |
- |
|
|
|
| (Cl. 10.7 of IS 374: 2019) (SPEED REGULATORS) |
- |
|
|
|
| (Cl. 10.7 of IS 374: 2019) (SPEED REGULATORS) |
- |
|
|
|
| (Cl. 10.8 of IS 374: 2019) (SPEED REGULATORS) |
- |
|
|
|
| (Cl. 11.2 of IS 374: 2019) (STARTING) |
- |
|
|
|
| (Cl. 13 of IS 374: 2019) (SILENT OPERATION) |
- |
|
|
|
| (Cl. 15.1 of IS 374: 2019) (PERFORMANCE REQUIREMENTS) |
- |
|
|
|
| (Cl. 15.1 of IS 374: 2019) (PERFORMANCE REQUIREMENTS) |
- |
|
|
|
| (Cl. 17 of IS 374: 2019 (Test for Harmonic Distortion) |
- |
|
|
|
| (Cl. 8.2 of IS 302-1: 2008) (PROTECTION AGAINST ACCESS TO LIVE PARTS) |
- |
|
|
|
| (Cl. 11 of IS 302-1: 2008) (HEATING) |
- |
|
|
|
| (Cl. 15 of IS 302-1: 2008) (MOISTURE RESISTANCE) |
- |
|
|
|
| (Cl. 15 of IS 302-1: 2008) (MOISTURE RESISTANCE) |
- |
|
|
|
| (Cl. 15 of IS 302-1: 2008. (MOISTURE RESISTANCE) |
- |
|
|
|
| (Cl. 17 of IS 302-1: 2008) (OVERLOAD PROTECTION OF TRANSFORMERS AND ASSOCIATED CIRCUITS) |
- |
|
|
|
| (Cl. 17 of IS 302-1: 2008) (OVERLOAD PROTECTION OF TRANSFORMERS AND ASSOCIATED CIRCUITS) |
- |
|
|
|
| (Cl. 19.13 of IS 302-1: 2008) (ABNORMAL OPERATION) |
- |
|
|
|
| (Cl. 19.7 of IS 302-1: 2008) (ABNORMAL OPERATION) |
- |
|
|
|
| (Cl. 19 of IS 302-2-80 :2017) (ABNORMAL OPERATION) |
- |
|
|
|
| (Cl. 19.13 of IS 302-1: 2008) (ABNORMAL OPERATION) |
- |
|
|
|
| (Cl. 19.13 of IS 302-1: 2008) (ABNORMAL OPERATION) |
- |
|
|
|
| (Cl. 19.13 of IS 302-1: 2008) (ABNORMAL OPERATION) |
- |
|
|
|
| (Cl. 19.13 of IS 302-1: 2008) (ABNORMAL OPERATION) |
- |
|
|
|
| (Cl. 20.102 of IS 302-2-80 :2017) (STABILITY AND MECHANICAL HAZARDS) |
- |
|
|
|
| (Cl. 22.2 of IS 302-1: 2008) (CONSTRUCTION) |
- |
|
|
|
| (Cl. 22.14 of IS 302-1: 2008) (CONSTRUCTION) |
- |
|
|
|
| (Cl. 22.18 of IS 302-1: 2008) (Electric Ceiling type fan-Specification) |
- |
|
|
|
| (Cl. 22.21 of IS 302-1: 2008) (CONSTRUCTION) |
- |
|
|
|
| (Cl. 22.22 of IS 302-1: 2008) (CONSTRUCTION) |
- |
|
|
|
| (Cl. 22.41 of IS 302-1: 2008) (CONSTRUCTION) |
- |
|
|
|
| (Cl. 22.44 of IS 302-1: 2008) (CONSTRUCTION) |
- |
|
|
|
| (Cl. 22.101 of IS 302-2-80: 2017) (CONSTRUCTION) |
- |
|
|
|
| (Cl. 23.1 of IS 302-1: 2008) (INTERNAL WIRING) |
- |
|
|
|
| (Cl. 23.2 of IS 302-1: 2008) (INTERNAL WIRING) |
- |
|
|
|
| (Cl. 23.4 of IS 302-1: 2008) (INTERNAL WIRING) |
- |
|
|
|
| (Cl. 23.5 of IS 302-1: 2008) (INTERNAL WIRING) |
- |
|
|
|
| (Cl. 23.6 of IS 302-1: 2008) (INTERNAL WIRING) |
- |
|
|
|
| (Cl. 23.7 of IS 302-1: 2008) (INTERNAL WIRING) |
- |
|
|
|
| (Cl. 23.9 of IS 302-1: 2008) (INTERNAL WIRING) |
- |
|
|
|
| (Cl. 23.10 of IS 302-1: 2008) (INTERNAL WIRING) |
- |
|
|
|
| (Cl. 24.1 of IS 302-1: 2008) (COMPONENTS) |
- |
|
|
|
| (Cl. 24.5 of IS 302-1: 2008) (COMPONENTS) |
- |
|
|
|
| (Cl. 24.105 of IS IS 302-2-80 :2017) (COMPONENTS) |
- |
|
|
|
| (Cl. 26.1 of IS 302-1: 2008) (TERMINALS FOR EXTERNAL CONDUCTORS) |
- |
|
|
|
| (Cl. 26.8 of IS 302-1: 2008) (TERMINALS FOR EXTERNAL CONDUCTORS) |
- |
|
|
|
| (Cl. 26.9 of IS 302-1: 2008) (TERMINALS FOR EXTERNAL CONDUCTORS) |
- |
|
|
|
| (Cl. 26.10 of IS 302-1: 2008) (TERMINALS FOR EXTERNAL CONDUCTORS) |
- |
|
|
|
| (Cl. 27.1 of IS 302-1: 2008) (PROVISION FOR EARTHING) |
- |
|
|
|
| (Cl. 27.2 of IS 302-1: 2008) (PROVISION FOR EARTHING) |
- |
|
|
|
| (Cl. 27.4 of IS 302-1: 2008) (PROVISION FOR EARTHING) |
- |
|
|
|
| (Cl. 27.5 of IS 302-1: 2008) (PROVISION FOR EARTHING) |
- |
|
|
|
| (Cl. 28.4 of IS 302-1: 2008) (SCREWS AND CONNECTIONS) |
- |
|
|
|
| (Cl. 30.2 of IS 302-1: 2008) (RESISTANCE TO HEAT AND FIRE) |
- |
|
|
|
| (Cl. 30.2 of IS 302-1: 2008) (RESISTANCE TO HEAT AND FIRE) |
- |
|
|
|
| (Cl. 32 of IS 302-1: 2008) (Radiation, toxicity and similar hazards) |
- |
|
|
|
|
- |
- - |
| 14735 |
BIS, Central Laboratory (CL)
| None
| IS 2745 (1983) |
Specification for non - Metal helmet for firemen and civil defence personnel (Second Revision) |
- |
1500 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl 3 (Shell, Protective padding, Retention System & Neck protector) |
- |
|
|
|
| Cl 5 ( Shell, Protective Padding, Brim, Head band, Chin Strap, Cradle, Neck Protector & Visor) |
- |
|
|
|
| Cl 6 (Workmanship & Finish) |
- |
|
|
|
| Cl 7 (Mass) |
- |
|
|
|
|
- |
- Excluding Test facility not available for Cl 4.1 sizes, Cl 9.1 Shock Absorption Test, Cl 9.2 Penetration Resistance, Cl 9.3 Strenth of Retention system; |
| 14736 |
BIS, Central Laboratory (CL)
| None
| IS 9562 (1980) |
Specification for non - Metal helmet for police force |
- |
Rs.2100/- View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl 3 (Shell, Protective padding & Retention System) |
- |
|
|
|
| Cl 5 ( Shell, Protective Padding, Brim, Head band, Chin Strap, Cradle, Neck Protector & Visor) |
- |
|
|
|
| Cl 6 (Workmanship & Finish) |
- |
|
|
|
| Cl 7 (Mass) |
- |
|
|
|
|
- |
- Exclusion Test facility not available for Cl 4.1 sizes, Cl 9.1 Shock Absorption Test, Cl 9.2 Penetration Resistance, Cl 9.3 Strenth of Retention system, Cl 9. Firing Test, Cl 9.6 Flammability Test; |
| 14737 |
BIS, Eastern Regional Laboratory (ERL)
| None
| IS 778 (1984) |
Specification for 2010 copper alloy gate, globe and check valves for waterworks purposes (Fourth Revision) |
For all classes except tests mentioned in remarks |
Rs 4500/- View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 3 (Nominal Sizes ) |
- |
|
|
|
| 4 (Classification ) |
- |
|
|
|
| 5 (Types) |
- |
|
|
|
| 7.1 (Valve Bodie - IS 778) |
- |
|
|
|
| 7.1.1 (Body End Ports -IS 778) |
- |
|
|
|
| 7.1.2 (Water-Way Area - IS 778) |
- |
|
|
|
| 7.1.3 (Screwed Body End -IS 778) |
- |
|
|
|
| 7.1.3.1-Table2 (length of threaded portion in screwed end valves - IS 778) |
- |
|
|
|
| 7.1.3.1 (Screwed Body End -IS 778) |
- |
|
|
|
| 7.1.5 (Wedge and Disc Guides in the Bodies of Gate Valves - IS 778) |
- |
|
|
|
| 7.2.1 (Bonnets - IS 778) |
- |
|
|
|
| 7.2.1.1 (Bonnets - IS 778) |
- |
|
|
|
| 7.2.1.2 (number of engaged threads - IS 778) |
- |
|
|
|
| 7.2.1.2 (pitch of threads - IS 778) |
- |
|
|
|
| 7.2.1.3 (Bonnets - IS 778) |
- |
|
|
|
| 7.3 (Stuffing Box - IS 778) |
- |
|
|
|
| 7.4 (Gland - IS 778) |
- |
|
|
|
| 7.4.1 (Gland nut - IS 778) |
- |
|
|
|
| 7.6.1 (Stem - IS 778) |
- |
|
|
|
| 7.6.2 (Threads of Stem - IS 778) |
- |
|
|
|
| 7.6.3 (actuating threads - IS 778) |
- |
|
|
|
| 7.6.4 (Length of Stem - IS 778) |
- |
|
|
|
| 7.6.5 (Upper end of Stem - IS 778) |
- |
|
|
|
| 7.6.7 (Non-rising Stem - IS 778) |
- |
|
|
|
| 7.6.6 (Rising Stem - IS 778) |
- |
|
|
|
| 7.7.1 (Wedge-IS 778) |
- |
|
|
|
| 7.7.2 (Wedge-IS 778) |
- |
|
|
|
| 7.7.3 (Double disc - IS 778) |
- |
|
|
|
| 7.7.3.1 (Spreading assembly - IS 778) |
- |
|
|
|
| 7.7.3.2 (Disc - IS 778) |
- |
|
|
|
| 7.10.1 (Body Seats - IS 778) |
- |
|
|
|
| 7.10.1 (Seat ring - IS 778) |
- |
|
|
|
| 7.11 (Handwheel - IS 778) |
- |
|
|
|
| 7.11 (Handwheel - IS 778) |
- |
|
|
|
| 8.1- Table 4 (Thickness of Body and Bonnet- IS 778) |
- |
|
|
|
| 8.2 - Table 5 (Flat to Flat size -IS 778 ) |
- |
|
|
|
| 8.3 - Table 6 (Width of end - IS 778) |
- |
|
|
|
| 8.4 - Table 7 (Stem Diameters - IS 778) |
- |
|
|
|
| 8.5 - Table 8 (Size of packing space - IS 778) |
- |
|
|
|
| 8.5 - Table 8 (Depth of stuffing box - IS 778) |
- |
|
|
|
| 8.5 - Table 8 (Dia of stuffing box - IS 778) |
- |
|
|
|
| 8.6- Table 9 to Table 12 (End to end/ centre to ends/ Face to face/Centre to face dimension ) |
- |
|
|
|
| 6- Table 1-i) (Brass(Body)-Cl 7 and table 1 of IS 1264) |
- |
|
|
|
|
- |
- Facility not available for hydraulic test & Thread measurement |
| 14738 |
BIS, Southern Regional Laboratory (SRL)
| None
| IS 8329 (2000) |
Centrifugally cast (Spun) ductile iron pressure pipes for water, gas and sewage - Specification (Third Revision) |
- |
Rs.7800/- View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl 10 (Hardness & Tensile Test) |
- |
|
|
|
| Cl 11 (Hydrostatic Test) |
- |
|
|
|
| Cl 13 (Length, Diameter, Wall Thickness & Ovality) |
- |
|
|
|
|
- |
- " 1 No.
Excluding Excl hydrostatic test, chemical facilty. Facility for preparation of test specimen not available. |
| 14739 |
BIS, Central Laboratory (CL)
| None
| IS 2925 (1984) |
Specification for industrial safety helmets (Second Revision) |
- |
Rs 7770/- View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 3.1 (Shell) |
- |
|
|
|
| 3.3 (Metal Parts) |
- |
|
|
|
| 4.1 (Sizes) |
- |
|
|
|
| 5.1 (Shell) |
- |
|
|
|
| 5.2 (Harness) |
- |
|
|
|
| 5.3 (Chin Strap or Nape Strap) |
- |
|
|
|
| 6.1 (Workmanship & Finish) |
- |
|
|
|
| 7.1 (Mass) |
- |
|
|
|
| 8.1 (Shock Absorption Resistance) |
- |
|
|
|
| 8.2 (Penetration Resistance) |
- |
|
|
|
| 8.4 (Electrical Resistance) |
- |
|
|
|
| 8.5 (Water Absorption) |
- |
|
|
|
| 8.6 (Heat Resistance) |
- |
|
|
|
| 3.1 (Shell) |
- |
|
|
|
|
- |
- - |
| 14740 |
BIS, Northern Regional Laboratory (NRL)
| None
| IS 2465 (1984) |
Specification for cables for motor vehicles (Second Revision) |
- |
Single core PVC Insulated Unsheathed: Rs. 11030/- View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 7.1 (Insulation) |
- |
|
|
|
| 7.3 (Insulation) |
- |
|
|
|
| 8 (Core Identification) |
- |
|
|
|
| 9 (Laying up of cores) |
- |
|
|
|
| 10.1.1 (Sheathing ) |
- |
|
|
|
| 10.2 (Sheathing ) |
- |
|
|
|
| 3 & 6 (Flexibility class) |
- |
|
|
|
| 3 & 6 (Construction) |
- |
|
|
|
| 3 & 6 (Diameter of wire(mm)) |
- |
|
|
|
| 3 & 6 (Annealing test) |
- |
|
|
|
| 3 & 6 (Persulphate Test) |
- |
|
|
|
| 3 & 6 (Conductor resistance Test (ohm/km at 20˚c)) |
- |
|
|
|
| 7.2, 10.3, 11 (Dimensions & thickness ) |
- |
|
|
|
| 7.2, 10.3, 11 (Dimensions & thickness ) |
- |
|
|
|
| 7.2, 10.3, 11 (Overall Dimension (mm)) |
- |
|
|
|
| 4.2 & 12.1 (Without Ageing For Insulation
Tensile Strength (N/mm²)) |
- |
|
|
|
| 4.2 & 12.1, (f), 1 (elongation at break (N/mm²)) |
- |
|
|
|
| 4.2 & 12.1, (f), 1 (Tensile Strength at break (N/mm²)) |
- |
|
|
|
| 4.2 & 12.1, (e), 1 (elongation test at break) |
- |
|
|
|
| 4.2 & 12.1, (e), 1 (Tensile strength at break) |
- |
|
|
|
| 4.2 & 12.1, (f), 2 (Ageing in air oven) |
- |
|
|
|
| 4.2 & 12.1, (f), 3 (Ageing in oxygen bomb) |
- |
|
|
|
| 4.2 & 12.1, (e), 2 (After Ageing in air oven) |
- |
|
|
|
| 4.2 & 12.1, (e), 3 (Loss of mass test (mg/cm²) of Insulation) |
- |
|
|
|
| 4.2 & 12.1, (e), 3 (Loss of mass test (mg/cm²) of Sheath) |
- |
|
|
|
| 4.2 & 12.1, (e), 4 (Hot deformation test (%) of Insulation) |
- |
|
|
|
| 4.2 & 12.1, (e), 4 (Hot deformation test (%) of Sheath) |
- |
|
|
|
| 4.2 & 12.1, (e), 5 (Heat Shock Test of Insulation) |
- |
|
|
|
| 4.2 & 12.1, (e), 5 (Heat Shock Test of Sheath) |
- |
|
|
|
| 4.2 & 12.1, (e), 6 (Shrinkage Test (%) of Insulation) |
- |
|
|
|
| 4.2 & 12.1, (e), 6 (Shrinkage Test (%) of Sheath) |
- |
|
|
|
| 14 (High Voltage Test) |
- |
|
|
|
| 22.1 (FLAMMABILITY TEST) |
- |
|
|
|
| 22.1 (FLAMMABILITY TEST) |
- |
|
|
|
| 23.1 (Manufacturer's Identification) |
- |
|
|
|
| 23.1 (Manufacturer's Identification) |
- |
|
|
|
| 24.1 (PACKING AND MARKING) |
- |
|
|
|
| 24.2 (PACKING AND MARKING) |
- |
|
|
|
| 24.2.1 (PACKING AND MARKING) |
- |
|
|
|
| 20.3 (EFFECT OF LUBRICATING OIL) |
- |
|
|
|
| 20.3 (EFFECT OF LUBRICATING OIL) |
- |
|
|
|
| 20.3 (EFFECT OF BRAKE FLUID) |
- |
|
|
|
| 20.3 (EFFECT OF BRAKE FLUID) |
- |
|
|
|
| 20.3 (EFFECT OF DIESEL) |
- |
|
|
|
| 20.3 (EFFECT OF DIESEL) |
- |
|
|
|
| 21.1 (EFFECT OF COOLING ON FLEXIBILITY) |
- |
|
|
|
| 21.2 (EFFECT OF COOLING ON FLEXIBILITY) |
- |
|
|
|
| 21.2 (EFFECT OF COOLING ON FLEXIBILITY) |
- |
|
|
|
|
- |
- "Complete for general wiring only & Partial for PVC Insulation ignition cable
Excluding Cl. 16 capacitance, Cl. 18 Effect of heat on flexibility" |
| 14741 |
BIS, Southern Regional Laboratory (SRL)
| None
| IS 1038 (1983) |
Specification For Steel Doors, Windows And Ventilators |
- |
3000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4.1. (Size-Height) |
- |
|
|
|
| 4.1 (Size-Width) |
- |
|
|
|
| 4.1. (Size-Height) |
- |
|
|
|
| 4.1 (Size-Width) |
- |
|
|
|
| 4.1. (Size-Height) |
- |
|
|
|
| 4.1 (Size-Width) |
- |
|
|
|
| 4.3 (Designation) |
- |
|
|
|
| 6.1.1.1 (Visual Inspection Test) |
- |
|
|
|
| 6.2 (Side Hung Shutter- Thickness of hinge) |
- |
|
|
|
| 6.2 (Side Hung Shutter- Pin diameter) |
- |
|
|
|
| 6.2 (Side Hung Shutter) |
- |
|
|
|
| 6.2 (Side Hung Shutter-Width of hinge) |
- |
|
|
|
| 6.2.2 & 6.2.2.1 (Handle and Handle Plate-Material of handel ) |
- |
|
|
|
| 6.2.2 & 6.2.2.1 (Handle and Handle Plate- Thicknesss of handle) |
- |
|
|
|
| 6.2.2 & 6.2.2.1 (Handle and Handle Plate-Height of handle plate) |
- |
|
|
|
| 6.2.3 (Peg Stay - Material) |
- |
|
|
|
| 6.2.3 (Peg Stay - Thickness) |
- |
|
|
|
| 6.2.3 (Peg Stay ) |
- |
|
|
|
| 6.3 (Top Hung Ventilator) |
- |
|
|
|
| 6.3 (Top Hung Ventilator-Thickness of hinge) |
- |
|
|
|
| 6.3 (Top Hung Ventilator-Pin diameter) |
- |
|
|
|
| 6.3 (Top Hung Ventilator-Width of hinge) |
- |
|
|
|
| 7.1 (Position of Holes) |
- |
|
|
|
| 7.2 Table 2 (Position of Fixing Screws) |
- |
|
|
|
| 7.2 Table 2 (Lugs-A) |
- |
|
|
|
| 7.2 Table 2 (Lugs-B) |
- |
|
|
|
| 7.2 Table 2 (Lugs-C) |
- |
|
|
|
| 7.2 Table 2 (Lugs-D) |
- |
|
|
|
| 7.2 Table 2 (Lugs-E) |
- |
|
|
|
| 6.2.3 (Peg Stay - Dimensions-F) |
- |
|
|
|
| 7.2 Table 2 (Lugs-G) |
- |
|
|
|
| 8 (Finish) |
- |
|
|
|
| 9 (Glazing) |
- |
|
|
|
|
- |
- " 1+1 NO.
Excluding Excl. micro and macro examination & Fillet weld test |
| 14742 |
BIS, Southern Regional Laboratory (SRL)
| None
| IS 4308 (2019) |
Dry Chemical Powders for Fire Fighting — BC, ABC and D Types — Specification ( Third Revision ) |
- |
Rs 5770/- for both ordinary type & foam compatible type View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Clause 5 Table 1(iii) (Apparent density (Declared value by
the manufacturer)) |
- |
|
|
|
| Clause 5 Table 1(iv) (Particle size / sieve analysis (Declared value by
the manufacturer)) |
- |
|
|
|
| Clause 5 Table 1(vi) (Water repellency) |
- |
|
|
|
| Clause 5 Table 1(vii) (Moisture content) |
- |
|
|
|
| Clause 5 Table 1(xii) (colour) |
- |
|
|
|
|
- |
- " 5 kg
Excluding Rate of flow, Foam compatibility, Fire Test, Temperature Resistance Test , chemical constituents |
| 14743 |
MSME TESTING CENTRE (WR), MUMBAI
| 7119404
| IS 694 (2010) |
Polyvinyl chloride insulated unsheathed and sheathed cables/cords with rigid and flexible conductor for rated voltages up to and including 450/750 v (Fourth Revision) |
PVC insulated unsheathed & sheathed cables/cords 110V |
22000 View breakup
Type test ₹12000 Singlecore/Unsheathed/01,₹16000
Singlecore/Sheathed/01,₹20000 Singlecore/Unsheathed/FR,₹22000
Singlecore/Sheathed/FR; Multicore: 25% extra for each additional core on single
core rate, Cat.02 ₹5000/- extra
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4.1(Tensile test (for Al)- After Stranding) |
- |
1800 |
|
Type test: i)Single core/Unsheathed/01:Rs.12,000/-, ii) Single core/sheathed/01:Rs.16000/- , iii)Single core/Unsheathed/FR:Rs.18000/-, iv)Single core/sheathed/FR:Rs.22000/- |
| 4.1(Tensile test (for Al)-Before Stranding) |
- |
1800 |
|
Acceptance test: i)Single core/Unsheathed/01:Rs.9,000/-, ii) Single core/sheathed/01:Rs.12000/- , iii)Single core/Unsheathed/FR:Rs.13500/-, iv)Single core/sheathed/FR:Rs.16500/- |
| 4.1(Annealing test (for copper)) |
- |
1800 |
|
For Multicore cables:25%extra for each additional core on single core rate |
| 4.1(Wrapping test (for Al)) |
- |
1500 |
|
- |
| 4.2(Conductor resistance test) |
- |
1800 |
|
- |
| Table 1(Category Code) |
- |
5000 |
|
For Cat.02 Rs.5000/- additional on above test charge |
| table 1 e) 3) (Volume Resistivity - Maximum temp) |
- |
1800 |
|
1800 |
| table 1 e) 3) (IR constant- Room temp ) |
- |
1800 |
|
1800 |
| table 1 e) 3) (IR constant- max. Temp) |
- |
1800 |
|
1800 |
| 5.1(Insulation) |
- |
2000 |
|
2000 |
| Table 1 iii) d) 7)(Thermal stability- Sheath ) |
- |
1800 |
|
1800 |
| Table 1 iii) d) 4)(Shrinkage- Sheath ) |
- |
3500 |
|
3500 |
| Table 1 iii) c) 5)(Heat shock-Insulation ) |
- |
1800 |
|
1800 |
| Table 1 iii) d) 6)(Hot deformation -Indentation depth - Sheath ) |
- |
2000 |
|
2000 |
| Table 1 iii) d) 8)(Cold bend for sheath) |
- |
3500 |
|
3500 |
| Table 1 iii) d) 9)(Cold impact for sheath) |
- |
3500 |
|
3500 |
| 10.4(Flammability test- Unaffected portion) |
- |
1800 |
|
1800 |
| 10.5(Oxygen index) |
- |
3500 |
|
3500 |
| 10.7(Temperature index) |
- |
3500 |
|
3500 |
| Table 1 iii) d) 2)(Loss of mass- Sheath ) |
- |
3000 |
|
3000 |
| Table 1 iii) d) 3)(Sheath- TS variation) |
- |
2000 |
|
2000 |
| Table 1 iii) c) 4)(Shrinkage-Insulation) |
- |
3500 |
|
3500 |
| Table 1 iii) d) 5)(Heat shock-Sheath ) |
- |
1800 |
|
1800 |
| 10.1(HV (water immersion)) |
- |
4000 |
|
4000 |
| 10.2(HV (room temperature)) |
- |
1800 |
|
1800 |
| 10.9(Additional ageing test (OU cables only) -HV test (at 60±3oC)) |
- |
5000 |
|
5000 |
|
- |
- - |
| 14744 |
MSME TESTING CENTRE (WR), MUMBAI
| 7119404
| IS 4250 (1980) |
Specification for domestic electric food - Mixers (Liquidizers And Grinders) (First Revision) |
Domestic Electric Food Mixers (Liquidizers & Grinders) |
16000 View breakup
Type test: Rs. 16,000/- ; Acceptance test Rs. 12,000/-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 7.1(Marking- IS 302-1) |
- |
1800 |
|
1800 |
| 8( Protection Against Electric Shock, IS 302-1) |
- |
1800 |
|
1800 |
| 9(Starting, IS 302-1) |
- |
1800 |
|
1800 |
| 10(Power Input and Current, IS 302-1) |
- |
1800 |
|
1800 |
| 11(Heating, IS 302-1) |
- |
2500 |
|
2500 |
| 13(Electrical Insulation and Leakage Current at Operating Temperature: Leakage current, IS 302-1) |
- |
1800 |
|
1800 |
| 15.1(Moisture Resistance, IS 302-1) |
- |
3000 |
|
3000 |
| 15.2(Moisture Resistance-Spillage test) |
- |
3000 |
|
3000 |
| 16(Electrical Insulation and Leakage Current at Operating Temperature: Leakage current, IS 302-1) |
- |
1800 |
|
1800 |
| 19(Abnormal Operation, IS 302-1) |
- |
1800 |
|
1800 |
| 21(Mechanical Strength, IS 302-1) |
- |
1800 |
|
1800 |
| 25(Supply Connection and External Flexible Cords, IS 302-1) |
- |
1800 |
|
1800 |
| 27(Provision for Earthing, IS 302-1) |
- |
1800 |
|
1800 |
| 28(Screws & Connections, IS 302-1) |
- |
1800 |
|
1800 |
| 29(Clearances and Distances through Insulation, IS 302-1) |
- |
1800 |
|
1800 |
| 30(Resistance to Heat, Fire, Tracking, IS 302-1) |
- |
3000 |
|
3000 |
| 34.2(Operational tests- Grinding coffee (for machines which have a dry grinding arrangement)) |
- |
2500 |
|
2500 |
| 34.3(Whisking egg whites ) |
- |
2500 |
|
2500 |
| 35(Temperature withstand test for bowl) |
- |
1500 |
|
1500 |
| 36(Test for controls ) |
- |
1800 |
|
1800 |
|
- |
- Type Test: Rs.14,000/-
Acceptance Test: Rs.10,500/- |
| 14745 |
MSME TESTING CENTRE (WR), MUMBAI
| 7119404
| IS 16102 : Part 1 (2012) |
Self - Ballasted led lamps for general lighting services: Part 1 safety requirements |
Self ballasted LED Lamps for general lighting service |
20000 View breakup
Type test Rs. 20,000/- ; Acceptance test Rs. 15,000/-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 5(Marking) |
- |
1800 |
|
1800 |
| 6(Interchangeability) |
- |
1800 |
|
1800 |
| 7(Protection against accidental contact with live parts) |
- |
1800 |
|
1800 |
| 8(Insulation Resistance and Electric Strength) |
- |
6000 |
|
6000 |
| 9(MECHANICAL STRENGTH) |
- |
2500 |
|
2500 |
| 10(cap temperature) |
- |
5000 |
|
5000 |
| 11(Resistance to Heat) |
- |
1800 |
|
1800 |
| 12(Resistance to Flame and Ignition) |
- |
2500 |
|
2500 |
| 13(Fault conditions) |
- |
1800 |
|
1800 |
| 14(Creepage distance and clearances) |
- |
1800 |
|
1800 |
|
- |
- Lamp Cap Type : B22d only |
| 14746 |
MSME TESTING CENTRE (WR), MUMBAI
| 7119404
| IS 1293 (2019) |
Plugs and socket - Outlets of rated Voltage up to and including 250 Volts and rated current up to and including 16 amperes - Specification (Third Revision) |
upto & including 250V & rated current upto 16A |
22000 View breakup
Type test : Rs.14,000/- for 6/10A; Rs. 16,000/- for 16A; Rs. 22,000/- for 6A/16A
combined socket. Acceptance test: Rs.10,500/- for 6/10A; Rs. 16,000/- for 16A;
Rs. 15,000/- for 6A/16A combined socket.
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 6(Ratings) |
- |
1800 |
|
Type Test:6A/10A:Rs.14000/-, 16A:Rs.16000/-, 6/16AMultiple Socket:Rs.20000/-
Acceptance Test:6A/10A:Rs.10500/-, 16A:Rs.12000/-, 6/16AMultiple Socket:Rs.15000/- |
| 7.1.1(Accessories Classification) |
- |
1800 |
|
Type Test:6A/10A:Rs.14000/-, 16A:Rs.16000/-, 6/16AMultiple Socket:Rs.20000/-
Acceptance Test:6A/10A:Rs.10500/-, 16A:Rs.12000/-, 6/16AMultiple Socket:Rs.15000/- |
| 7.1.2(Accessories Classification) |
- |
1800 |
|
1800 |
| 7.1.3(Accessories Classification) |
- |
1800 |
|
1800 |
| 7.1.4(Accessories Classification) |
- |
1800 |
|
1800 |
| 7.1.5(Accessories Classification) |
- |
1800 |
|
1800 |
| 7.2.1(Socket-Outlets Classification) |
- |
1800 |
|
1800 |
| 7.2.2(Socket-Outlets Classification) |
- |
1800 |
|
1800 |
| 7.2.3(Socket-Outlets Classification) |
- |
1800 |
|
1800 |
| 7.2.4(Socket-Outlets Classification) |
- |
1800 |
|
1800 |
| 7.3(Plug Classification) |
- |
1800 |
|
1800 |
| 8.1(MARKING) |
- |
1800 |
|
1800 |
| 8.8(MARKING) |
- |
1800 |
|
1800 |
| 8.9(MARKING) |
- |
1800 |
|
1800 |
| 9.1(CHECKING OF DIMENSIONS) |
- |
1800 |
|
1800 |
| 9.2(CHECKING OF DIMENSIONS) |
- |
1800 |
|
1800 |
| 10.1(PROTECTION AGAINST ELECTRIC SHOCK) |
- |
1800 |
|
1800 |
| 10.3(PROTECTION AGAINST ELECTRIC SHOCK) |
- |
1800 |
|
1800 |
| 10.4(PROTECTION AGAINST ELECTRIC SHOCK) |
- |
1800 |
|
1800 |
| 10.5(PROTECTION AGAINST ELECTRIC SHOCK) |
- |
1800 |
|
1800 |
| 10.6(PROTECTION AGAINST ELECTRIC SHOCK) |
- |
1800 |
|
1800 |
| 10.7(PROTECTION AGAINST ELECTRIC SHOCK) |
- |
1800 |
|
1800 |
| 11.1(PROVISIONS FOR EARTHING) |
- |
1800 |
|
1800 |
| 11.2(PROVISIONS FOR EARTHING) |
- |
1800 |
|
1800 |
| 11.3(PROVISIONS FOR EARTHING) |
- |
1800 |
|
1800 |
| 11.4(PROVISIONS FOR EARTHING) |
- |
1800 |
|
1800 |
| 11.5(PROVISIONS FOR EARTHING) |
- |
1800 |
|
1800 |
| 11.6(PROVISIONS FOR EARTHING) |
- |
1800 |
|
1800 |
| 12.1.1(TERMINALS) |
- |
2500 |
|
2500 |
| 12.1.2(TERMINALS) |
- |
2500 |
|
2500 |
| 12.2.1(TERMINALS) |
- |
2500 |
|
- |
| 12.2.2(TERMINALS) |
- |
2500 |
|
2500 |
| 12.2.3(TERMINALS) |
- |
2500 |
|
2500 |
| 12.2.4(TERMINALS) |
- |
2500 |
|
2500 |
| 12.2.5(TERMINALS) |
- |
2500 |
|
2500 |
| 12.2.6(TERMINALS) |
- |
2500 |
|
2500 |
| 12.2.7(TERMINALS) |
- |
2500 |
|
2500 |
| 12.2.8(TERMINALS) |
- |
2500 |
|
2500 |
| 12.2.9(TERMINALS) |
- |
2500 |
|
2500 |
| 12.2.10(TERMINALS) |
- |
2500 |
|
2500 |
| 12.2.11(TERMINALS) |
- |
2500 |
|
2500 |
| 12.3.1(TERMINALS) |
- |
2500 |
|
2500 |
| 12.3.2(TERMINALS) |
- |
2500 |
|
2500 |
| 12.3.4(TERMINALS) |
- |
2500 |
|
2500 |
| 12.3.5(TERMINALS) |
- |
2500 |
|
2500 |
| 12.3.6(TERMINALS) |
- |
2500 |
|
2500 |
| 12.3.7(TERMINALS) |
- |
2500 |
|
2500 |
| 12.3.8(TERMINALS) |
- |
2500 |
|
2500 |
| 12.3.9(TERMINALS) |
- |
2500 |
|
2500 |
| 12.3.10(TERMINALS) |
- |
2500 |
|
2500 |
| 12.3.11(TERMINALS) |
- |
2500 |
|
2500 |
| 12.3.12(TERMINALS) |
- |
2500 |
|
2500 |
| 13.1(CONSTRUCTIONS OF FIXED SOCKETOUTLETS) |
- |
2500 |
|
2500 |
| 13.2(CONSTRUCTIONS OF FIXED SOCKETOUTLETS) |
- |
2500 |
|
2500 |
| 13.3(CONSTRUCTIONS OF FIXED SOCKETOUTLETS) |
- |
2500 |
|
2500 |
| 13.4(CONSTRUCTIONS OF FIXED SOCKETOUTLETS) |
- |
2500 |
|
2500 |
| 13.5(CONSTRUCTIONS OF FIXED SOCKETOUTLETS) |
- |
2500 |
|
2500 |
| 13.6(CONSTRUCTIONS OF FIXED SOCKETOUTLETS) |
- |
2500 |
|
2500 |
| 13.7(CONSTRUCTIONS OF FIXED SOCKETOUTLETS) |
- |
2500 |
|
2500 |
| 13.8(CONSTRUCTIONS OF FIXED SOCKETOUTLETS) |
- |
2500 |
|
2500 |
| 13.9(CONSTRUCTIONS OF FIXED SOCKETOUTLETS) |
- |
2500 |
|
2500 |
| 13.11(CONSTRUCTIONS OF FIXED SOCKETOUTLETS) |
- |
2500 |
|
2500 |
| 13.12(CONSTRUCTIONS OF FIXED SOCKETOUTLETS) |
- |
2500 |
|
2500 |
| 13.13(CONSTRUCTIONS OF FIXED SOCKETOUTLETS) |
- |
2500 |
|
2500 |
| 13.14(CONSTRUCTIONS OF FIXED SOCKETOUTLETS) |
- |
2500 |
|
2500 |
| 13.15(CONSTRUCTIONS OF FIXED SOCKETOUTLETS) |
- |
2500 |
|
2500 |
| 13.16(CONSTRUCTIONS OF FIXED SOCKETOUTLETS) |
- |
2500 |
|
2500 |
| 13.17(CONSTRUCTIONS OF FIXED SOCKETOUTLETS) |
- |
2500 |
|
2500 |
| 13.18(CONSTRUCTIONS OF FIXED SOCKETOUTLETS) |
- |
2500 |
|
2500 |
| 13.19(CONSTRUCTIONS OF FIXED SOCKETOUTLETS) |
- |
2500 |
|
2500 |
| 13.21(CONSTRUCTIONS OF FIXED SOCKETOUTLETS) |
- |
2500 |
|
2500 |
| 13.22(CONSTRUCTIONS OF FIXED SOCKETOUTLETS) |
- |
2500 |
|
2500 |
| 13.23(CONSTRUCTIONS OF FIXED SOCKETOUTLETS) |
- |
2500 |
|
2500 |
| 14.1(CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
2500 |
|
2500 |
| 14.26(CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
2500 |
|
2500 |
| 15(INTERLOCKED SOCKET-OUTLETS) |
- |
2500 |
|
2500 |
| 16.1(RESISTANCE TO AGEING,) |
- |
3000 |
|
3000 |
| 16.2(RESISTANCE TO HARMFUL INGRESS OF WATER AND TO HUMIDITY) |
- |
3000 |
|
3000 |
| 16.3(Resistance to Humidity) |
- |
3000 |
|
3000 |
| 17.1(INSULATION RESISTANCE AND ELECTRIC STRENGTH) |
- |
1800 |
|
1800 |
| 17.2(INSULATION RESISTANCE AND ELECTRIC STRENGTH) |
- |
1800 |
|
1800 |
| 17.3(INSULATION RESISTANCE AND ELECTRIC STRENGTH) |
- |
1800 |
|
1800 |
| 18(OPERATION OF EARTHING CONTACTS) |
- |
1800 |
|
1800 |
| 19(TEMPERATURE RISE) |
- |
2500 |
|
2500 |
| 20(BREAKING CAPACITY) |
- |
2000 |
|
2000 |
| 21(NORMAL OPERATION) |
- |
4000 |
|
4000 |
| 22.1(Verification of the Maximum Withdrawal Force) |
- |
1800 |
|
1800 |
| 22.2(Verification of Minimum Withdrawal Force) |
- |
1800 |
|
1800 |
| 23.1(FLEXIBLE CABLES AND THEIR CONNECTION) |
- |
1800 |
|
1800 |
| 23.3(FLEXIBLE CABLES AND THEIR CONNECTION) |
- |
1800 |
|
1800 |
| 24.1(MECHANICAL STRENGTH
For all kinds of fixed socket-outlets
) |
- |
1800 |
|
1800 |
| 24.2(MECHANICAL STRENGTH
For portable single socket-outlets:
1) with enclosures, covers or bodies other than thermoplastic or elastomeric material) |
- |
1800 |
|
1800 |
| 24.3(MECHANICAL STRENGTH
for fixed socket-outlets with a main part intended to be mounted directly on a surface) |
- |
1800 |
|
1800 |
| 24.4(MECHANICAL STRENGTH
For portable single socket-outlets:
1) with enclosures, covers or bodies of thermoplastic or elastomeric material) |
- |
1800 |
|
1800 |
| 24.5(MECHANICAL STRENGTH
For portable single socket-outlets:
1) with enclosures, covers or bodies of thermoplastic or elastomeric material) |
- |
1800 |
|
1800 |
| 24.6(MECHANICAL STRENGTH
For screwed glands of accessories having an IP code higher than IP20) |
- |
1800 |
|
1800 |
| 25.1(RESISTANCE TO HEAT
Accessories and surface mounting boxes) |
- |
2500 |
|
2500 |
| 25.2(RESISTANCE TO HEAT
Parts of insulating material necessary to retain
current-carrying parts of the earthing circuit in position,
as well as parts of the front surface zone of thermoplastic material) |
- |
2500 |
|
2500 |
| 25.3(RESISTANCE TO HEAT
Parts of insulating material not necessary to retain current-carrying parts and parts of the earthing circuit in position, even though they are in contact with them) |
- |
2500 |
|
2500 |
| 25.4(RESISTANCE TO HEAT
) |
- |
2500 |
|
2500 |
| 25.1(RESISTANCE TO HEAT
Accessories and surface mounting boxes) |
- |
2500 |
|
2500 |
| 26.1(SCREWS, CURRENT-CARRYING PARTS AND CONNECTIONS) |
- |
1800 |
|
1800 |
| 26.2(SCREWS, CURRENT-CARRYING PARTS AND CONNECTIONS) |
- |
1800 |
|
1800 |
| 27.1(CREEPAGE DISTANCES, CLEARANCES AND DISTANCES THROUGH SEALING COMPOUND) |
- |
1800 |
|
1800 |
| 27.2(CREEPAGE DISTANCES, CLEARANCES AND DISTANCES THROUGH SEALING COMPOUND) |
- |
1800 |
|
1800 |
| 28.1.1(Resistance to Abnormal Heat and to Fire
Glow-Wire Test) |
- |
2500 |
|
2500 |
| 28.1.2(Resistance to Abnormal Heat and to Fire
for plugs with pins provided with insulating sleeves) |
- |
2500 |
|
2500 |
| 28.2(Resistance to Tracking
For accessories other than IP code higher than IPX0 parts of insulating material retaining live parts in position) |
- |
2500 |
|
2500 |
| 29(RESISTANCE TO RUSTING) |
- |
1800 |
|
1800 |
| 30.1(ADDITIONAL TESTS ON PINS PROVIDED WITH INSULATING SLEEVES
Pressure Test at High Temperature) |
- |
1800 |
|
1800 |
| 30.2(ADDITIONAL TESTS ON PINS PROVIDED WITH INSULATING SLEEVES
Static Damp Heat Test) |
- |
1800 |
|
1800 |
| 30.3(ADDITIONAL TESTS ON PINS PROVIDED WITH INSULATING SLEEVES
Tests at Low Temperature) |
- |
1800 |
|
1800 |
| 30.4(ADDITIONAL TESTS ON PINS PROVIDED WITH INSULATING SLEEVES
Impact Test at Low Temperature) |
- |
1800 |
|
1800 |
|
- |
- - |
| 14747 |
MSME TESTING CENTRE (WR), MUMBAI
| 7119404
| IS 14927 : Part 2 (2001) |
Cable Trunking and Ducting Systems for Electrical Installations : Part 2 Cable Trunking and Ducting Systems Intended for Mounting on Walls or Ceiling |
1 |
12000 View breakup
Rs 12,000 For complete IS
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 7.1(Marking (as per Cl 7.1 of IS:14927(Pt-I ):2001)) |
- |
1000 |
|
1000 |
| 7.2(Marking (as per Cl 7.2 of IS:14927(Pt-I ):2001)) |
- |
1000 |
|
1000 |
| 8.1( Dimensions (As per cl.8.1 of IS 14927(Pt-1) : 2001)) |
- |
1000 |
|
1000 |
| 8.2(Dimensions (As per cl.8.2 of IS 14927(Pt-1) : 2001) |
- |
1000 |
|
1000 |
| 8.3, table 2( Dimensions (As per cl.8.3 and Table-2 of IS 14927(Pt-1) : 2001)) |
- |
1000 |
|
1000 |
| 9.1(Construction) |
- |
2000 |
|
2000 |
| 9.2(Construction ( As per Cl. 9.2 of IS 14927(Pt-1):2001)) |
- |
2000 |
|
2000 |
| 9.3(Construction ( As per Cl. 9.3 of IS 14927(Pt-1):2001)) |
- |
2000 |
|
2000 |
| 9.4.1(Construction [Access to Live Parts (As per Cl. 9.4.1 of IS 14927(Pt-1):2001)]) |
- |
2000 |
|
2000 |
| 9.5(Construction (As per Cl. 9.5 of IS 14927(Pt-1):2001)) |
- |
2000 |
|
2000 |
| 9.6.2(Construction [Membranes (As per Cl.9.6.2 of IS: 14927 (Pt-1):2001)]) |
- |
2000 |
|
2000 |
| 9.6.4(Construction [Membranes (As per Cl.9.6.4 of IS: 14927 (Pt-1):2001)]) |
- |
2000 |
|
2000 |
| 9.7.2, table 4(Construction [Glands (As per Cl.9.7.2 and Table-4 of IS: 14927 (Pt-1):2001)] ) |
- |
2000 |
|
2000 |
| 10.2(Cable supporting test for Surface mounting (As per Cl.10.2)) |
- |
2000 |
|
2000 |
| 10.3(Impact Test [ Cl.10.3 ]) |
- |
2000 |
|
2000 |
| 10.4(Linear Deflection Test [ Cl.10.4 ]) |
- |
2000 |
|
2000 |
| 11.1.1(Resistance to flame propagation (As per Cl. 11.1.1)) |
- |
1000 |
|
1000 |
| 12(Electrical Insulating Strength and Insulation Resistance Test. [ Cl.12.3 ]) |
- |
3000 |
|
3000 |
| 10.2(Cable supporting test for Surface mounting (As per Cl.10.2)) |
- |
2000 |
|
2000 |
|
- |
- - |
| 14748 |
MSME TESTING CENTRE (WR), MUMBAI
| 7119404
| IS 9537 : Part 3 (1983) |
Specification for conduits for electrical installations: Part 3 rigid plain conduits of insulating meterials |
- |
14000 View breakup
Rs 14,000 For complete IS
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 8.1(Construction as per clause 8 of IS: 9537 (Part 1)-1980) |
- |
1000 |
|
Rs.14,000/- for BIS Samples Rs.4950/- for upto and including 25mm, Rs.4,275/- for above 25mm |
| 6.1(Marking) |
- |
1000 |
|
Rs.14,000/- for BIS Samples Rs.4950/- for upto and including 25mm, Rs.4,275/- for above 25mm |
| 6.2(Durability of Marking as per 6.4 of IS: 9537 (Part 1)-1980) |
- |
1000 |
|
1000 |
| 7.1.1(Maximum and minimum outside diameter of socket) |
- |
1000 |
|
1000 |
| 7.1.1 Table-2(Length of Socket end) |
- |
1000 |
|
1000 |
| 7.1.2(Maximum and minimum outside diameter of conduit) |
- |
1000 |
|
1000 |
| 7.2(Minimum inside diameter of conduit) |
- |
1000 |
|
1000 |
| 7.3(Length of conduit) |
- |
1000 |
|
1000 |
| 7.4(Unifomity of The wall Thickness) |
- |
1000 |
|
1000 |
| 9.2(Bending Test i) At Room Temp ii) At Low Temp (-5 ±2°C)) |
- |
2000 |
|
2000 |
| 9.3(Compression Test as per caluse 9.3 of IS: 9537 (Part 1)-1980) |
- |
2000 |
|
2000 |
| 9.4(Impact Test as per clause 9.4 of IS: 9537 (Part 1)-1980) |
- |
2000 |
|
2000 |
| 9.5(Collapse Test as per clause 9.5 of IS: 9537 (Part 1)-1980) |
- |
2000 |
|
2000 |
| 10(Resistance to Heat -Ball presure test) |
- |
2000 |
|
2000 |
| 11(Resistance to burning as per clause 11 of IS: 9537 (Part 1)-1980) |
- |
1000 |
|
1000 |
| 12(Electrical Characteristics-Test for electric strength as per clause 12.1.1 of IS: 9537 (Part 1)-1980) |
- |
3000 |
|
3000 |
| 12(Electrical Characteristics-Insulation resistance test as per clause 12.1.2 of IS: 9537 (Part 1)-1980) |
- |
3000 |
|
3000 |
|
- |
- - |
| 14749 |
MSME TESTING CENTRE (WR), MUMBAI
| 7119404
| IS 3419 (1988) |
Specification for fittings for rigid non - Metallic (Second Revision) |
- |
10000 View breakup
Rs 10,000 For complete IS
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 8 & 5(Visual Examination -IS:3419) |
- |
1000 |
|
1000 |
| 6.2 & 9.1- Table-1, ii(Inside Diameter of Collar for Slip type cuplers -IS:3419) |
- |
2000 |
|
2000 |
| 6.2 & 9.1- Table-1, iii(Inside Diameter of Ridge for Slip type cuplers -IS:3419) |
- |
2000 |
|
2000 |
| 6.2 & 9.1- Table-1, iv(Minimum overall length for Slip type cuplers -IS:3419) |
- |
2000 |
|
2000 |
| 6.2 & 9.1- Table-1, v(Minimum wall thickness for Slip type cuplers -IS:3419) |
- |
2000 |
|
2000 |
| 6.2 & 9.1- Table-2, ii(Inside Diameter of Collar for Socketed type cuplers -IS:3419) |
- |
2000 |
|
2000 |
| 6.2 & 9.1- Table-2, iii(Inside Diameter of Ridge for Socketed type cuplers -IS:3419) |
- |
2000 |
|
2000 |
| 6.2 & 9.1- Table-2, iv(Minimum overall length (a) for Socketed type cuplers -IS:3419) |
- |
2000 |
|
2000 |
| 6.2 & 9.1- Table-2, v(Minimum overall length (l) for Socketed type cuplers -IS:3419) |
- |
2000 |
|
2000 |
| 6.2 & 9.1- Table-2, vi(Minimum wall thickness for Socketed type cuplers -IS:3419) |
- |
2000 |
|
2000 |
| 6.2 & 9.1- Table-3, ii(Inside Diameter of Collar(d6) for Clamp type cuplers -IS:3419) |
- |
2000 |
|
2000 |
| 6.2 & 9.1- Table-3, iv(Inside Diameter of Ridge for Clamp type cuplers -IS:3419) |
- |
2000 |
|
2000 |
| 6.2 & 9.1- Table-3, iv(Minimum length for Clamp type cuplers -IS:3419) |
- |
2000 |
|
2000 |
| 6.2 & 9.1- Table-4, v(Length (l1) of Normal Type Bend -IS:3419) |
- |
2000 |
|
2000 |
| 6.2 & 9.1- Table-3, vi(Minimum wall thickness for Clamp type cuplers -IS:3419) |
- |
2000 |
|
2000 |
| 6.2 & 9.1- Table-4, ii(Outside Dameter of Normal type bend -IS:3419) |
- |
2000 |
|
2000 |
| 6.2 & 9.1- Table-4, iii(Minimum Inside Diameter of Normal Type Bend -IS:3419) |
- |
2000 |
|
2000 |
| 6.2 & 9.1- Table-4, iv(Radious(R) of Normal Type Bend -IS:3419) |
- |
2000 |
|
2000 |
| 6.2 & 9.1- Table-5, ii(Outside Dameter of Slip type cupling bend -IS:3419) |
- |
2000 |
|
2000 |
| 6.2 & 9.1- Table-5, iii(Minimum Inside Diameter of Slip type cupling bend -IS:3419) |
- |
2000 |
|
2000 |
| 6.2 & 9.1- Table-5, iv(Inside Diameter of collar for Slip type cupling bend -IS:3419) |
- |
2000 |
|
2000 |
| 6.2 & 9.1- Table-5, v(R- for Slip type cupling bend -IS:3419) |
- |
2000 |
|
2000 |
| 6.2 & 9.1- Table-5, vi(Y- for Slip type cupling bend -IS:3419) |
- |
2000 |
|
2000 |
| 6.2 & 9.1- Table-5, vii(l2- for Slip type cupling bend -IS:3419) |
- |
2000 |
|
2000 |
| 6.2 & 9.1- Table-6, ii(Inside Diameter of collar for Normal type Elbows -IS:3419) |
- |
2000 |
|
2000 |
| 6.2 & 9.1- Table-6, iii(Length (l) of Normal Type Elbows -IS:3419) |
- |
2000 |
|
2000 |
| 6.2 & 9.1- Table-6, iv(Radious(r) of Normal Type Elbows -IS:3419) |
- |
2000 |
|
2000 |
| 6.2 & 9.1- Table-6, v(Minimum wall thicknes of Elbows -IS:3419) |
- |
2000 |
|
2000 |
| 6.2 & 9.1- Table-7, ii(Inside Diameter of Collear for Normal type Tees -IS:3419) |
- |
2000 |
|
2000 |
| 6.2 & 9.1- Table-7, iii(Length (l) of Normal type Tees -IS:3419) |
- |
2000 |
|
2000 |
| 6.2 & 9.1- Table-7, iv(Radious(r) of Normal type Tees -IS:3419) |
- |
2000 |
|
2000 |
| 6.2 & 9.1- Table-7, v( Minimum wall thicknes of Normal type Tees -IS:3419) |
- |
2000 |
|
2000 |
| 6.2 & 9.1- Table-8, ii(Inside Diameter of Collear for socketed type Tees - IS:3419) |
- |
2000 |
|
2000 |
| 6.2 & 9.1- Table-8, iii(a - of socketed type Tees -IS:3419) |
- |
2000 |
|
2000 |
| 6.2 & 9.1- Table-8, iv(l - of socketed type Tees -IS:3419) |
- |
2000 |
|
2000 |
| 6.2 & 9.1- Table-8, v(Minimum wall thicknes of socketed type Tees -IS:3419) |
- |
2000 |
|
2000 |
| 6.2 & 9.1- Table-9, ii(B - of spout Type Circular Boxes -IS:3419) |
- |
2000 |
|
2000 |
| 6.2 & 9.1- Table-9, iii(C - of spout Type Circular Boxes -IS:3419) |
- |
2000 |
|
2000 |
| 6.2 & 9.1- Table-9, iv(D - of spout Type Circular Boxes -IS:3419) |
- |
2000 |
|
2000 |
| 6.2 & 9.1- Table-9, v(E - of spout Type Circular Boxes -IS:3419) |
- |
2000 |
|
2000 |
| 6.2 & 9.1- Table-9, vi(F(Max) - of spout Type Circular Boxes -IS:3419) |
- |
2000 |
|
2000 |
| 6.2 & 9.1- Table-9, vii(F(Min) - of spout Type Circular Boxes -IS:3419) |
- |
2000 |
|
2000 |
| 6.2 & 9.1- Table-9, viii(G - of spout Type Circular Boxes -IS:3419) |
- |
2000 |
|
2000 |
| 6.2 & 9.1- Table-9, ix(t - of spout Type Circular Boxes -IS:3419) |
- |
2000 |
|
2000 |
| 10(Resistance to Heat -IS:3419) |
- |
2000 |
|
2000 |
| 11(Resistance to Burning - IS 3419) |
- |
2000 |
|
2000 |
| 12(Moisture Absorption - IS 3419) |
- |
2000 |
|
2000 |
| 13.2 &13.3(Resistance to chemival action in Acid solution - IS 3419) |
- |
2000 |
|
2000 |
| 13.2 &13.3(Resistance to chemival action in Alkaline solution - IS 3419) |
- |
2000 |
|
2000 |
| 14.1(Copper Test - IS 3419) |
- |
2000 |
|
2000 |
| 15, 15.3(Resistance to Oil - IS 3419) |
- |
2000 |
|
2000 |
| 15,15.4(Resistance to Oil - IS 3419) |
- |
2000 |
|
2000 |
| 16- Appendix-A(Resistance to Impact -IS 3419) |
- |
2000 |
|
2000 |
| 17.2(Electric Strength - IS 3419) |
- |
2000 |
|
2000 |
| 17.3(Insulation Resistance - IS 3419) |
- |
2000 |
|
2000 |
|
- |
- - |
| 14750 |
BIS, Southern Regional Laboratory (SRL)
| None
| IS 11722 (1986) |
Specification for thin walled flexible quick coupling pipes |
- |
4800 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4.1 (Pipe Manufacturing Process ) |
- |
|
|
|
| 5,5.1 (Workmsnship &Finish) |
- |
|
|
|
| 6 &7 ; Table 1 (Dimension & Tolerance) |
- |
|
|
|
| 8 (Length) |
- |
|
|
|
| 12 (Straightness) |
- |
|
|
|
| 13.1 (Flattening Test,IS 2328) |
- |
|
|
|
| 13.2 (Tensile Test ,; IS 1608(P1)) |
- |
|
|
|
|
- |
- " 2 nos.+coupler
Excluding excl hydraulic test,chemical tests |
| 14751 |
BIS, Southern Regional Laboratory (SRL)
| None
| IS 4224 (1972) |
Specification for steel wire for staples, pins and clips (First Revision) |
- |
525 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4 (Freedom from defects , IS 4224) |
- |
|
|
|
| 5 (Sizes and Tolerances - IS 4224) |
- |
|
|
|
| 6 (Finish) |
- |
|
|
|
| 7.1 (Tensile Test - IS 1608(Pt -1)) |
- |
|
|
|
|
- |
- " 5 m + 100g drill.
Excluding chemical test |
| 14752 |
BIS, Southern Regional Laboratory (SRL)
| None
| IS 903 (1993) |
Specification for Fire Hose Delivery Couplings, Branch Pipe, Nozzles And Nozzle Spanner - Specificaion |
- |
Rs 3600/ View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 3 (Finish and workmanship) |
- |
|
|
|
| 4 (Marking) |
- |
|
|
|
| 5 (Delivery hose coupling) |
- |
|
|
|
| 5.3 (Size and Dimension ) |
- |
|
|
|
| 7.3 (Hydraulic test requirement) |
- |
|
|
|
| 6 (Branch pipe) |
- |
|
|
|
| 6.3 (Hydraulic test requirement) |
- |
|
|
|
| 7 (Nozzle) |
- |
|
|
|
| 7.3 (Hydraulic test requirement) |
- |
|
|
|
| 8.2 (Shape & Dimensions of Spanner) |
- |
|
|
|
| 8.4 (Deflection test of Spanner) |
- |
|
|
|
|
- |
- " 1 pcs
Excluding Except Hydraulic Test Requirement, Deflection Test Requirement,chemical tests |
| 14753 |
BIS, Southern Regional Laboratory (SRL)
| None
| IS 13997 (2014) |
Drums, large open top - Specification (First Revision) |
- |
- View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 5, Table 1 (Dimensions-D2) |
- |
|
|
|
| 5, Table 1 (Dimensions-D3) |
- |
|
|
|
| 5, Table 1 (Dimensions-D4) |
- |
|
|
|
| 5, Table 1 (Dimensions-H1) |
- |
|
|
|
| 5, Table 1 (Dimensions-H5) |
- |
|
|
|
| 5, Table 1 (Dimensions-h2) |
- |
|
|
|
| 5, Table 1 (Dimensions-h3) |
- |
|
|
|
| 5, Table 1 (Dimensions-h4) |
- |
|
|
|
| 5, Table 1 (Dimensions-p1) |
- |
|
|
|
| 6.2 (The nominal thickness of steel sheets for body
and ends ) |
- |
|
|
|
| 7.1 ( CONSTRUCTION) |
- |
|
|
|
| 7.2 ( CONSTRUCTION) |
- |
|
|
|
| 7.3 ( CONSTRUCTION- Double Seam/Spiral Seam/Triple Seam Construction for Grade A Drums) |
- |
|
|
|
| 7.4 ( CONSTRUCTION-Spiral Seam/Triple Seam Construction for Grade B Drums) |
- |
|
|
|
| 7.5 ( CONSTRUCTION) |
- |
|
|
|
| 7.6 ( CONSTRUCTION) |
- |
|
|
|
| 7.7 ( CONSTRUCTION) |
- |
|
|
|
| 7.8 ( CONSTRUCTION) |
- |
|
|
|
| 7.9 (Closures) |
- |
|
|
|
| 7.10(a) (Closures) |
- |
|
|
|
| 7.10(b) (Closures) |
- |
|
|
|
| 7.10(c) (Closures) |
- |
|
|
|
| 7.10(d) (Closures) |
- |
|
|
|
| 7.11 ( Locking Ring) |
- |
|
|
|
| 8.1 (FINISH
) |
- |
|
|
|
| 8.2 (FINISH
) |
- |
|
|
|
| 9 (leakage test) |
- |
|
|
|
|
- |
- - |
| 14754 |
BIS, Southern Regional Laboratory (SRL)
| None
| IS 2653 (2004) |
Safety matches in boxes - Specification (Third Revision) |
- |
Rs 2570.00 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 5.1.2.1 (Matchboxes) |
- |
|
|
|
| 5.1.2.2 (Matchboxes) |
- |
|
|
|
| 5.1.3 (Envelopment) |
- |
|
|
|
| 5.1.4 (Ease of Opening) |
- |
|
|
|
| 5.1.5 (Retention of Contents) |
- |
|
|
|
| 5.1.6.1 (Defective Match Boxes) |
- |
|
|
|
| 5.1.6.2 (Defective Match Boxes) |
- |
|
|
|
| 5.2.1.1 (Match Splints) |
- |
|
|
|
| 5.2.1.2 (Match Splints) |
- |
|
|
|
| 5.2.1.2 (Minimum thickness) |
- |
|
|
|
| 5.2.1.2 (Average thickness) |
- |
|
|
|
| 5.2.2 (Unserviceable Sticks) |
- |
|
|
|
| 5.3 (Match Boxes) |
- |
|
|
|
| 6.1.1 (Striking Performance - General) |
- |
|
|
|
| 6.1.2 (Safety Matches) |
- |
|
|
|
| 6.2 (Ignition Below 170 ˚C) |
- |
|
|
|
| 6.3 (Ignition Under Impact) |
- |
|
|
|
| 6.4.1 (Durability of the Striking Surface) |
- |
|
|
|
| 6.4.2 (Ignition of the Striking Surface) |
- |
|
|
|
| 6.4.3 (Loss of Burning Fragments) |
- |
|
|
|
| 6.5 (Damp Proofness for Match Boxes) |
- |
|
|
|
|
- |
- " 2 dozen |
| 14755 |
BIS, Southern Regional Laboratory (SRL)
| None
| IS 3196 : Part 2 (2006) |
Welded low carbon steel cylinders exceeding 5 litre water capacity for low pressure liquefiable gases: Part 2 cylinders for liquefiable non - Toxic gases other than lpg - Specification (First Revision) |
- |
- View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 19 (Marking) |
- |
|
|
|
| 9 (Valve Connection) |
- |
|
|
|
| 9 (Valve Protection) |
- |
|
|
|
| 9 (Valve Protection) |
- |
|
|
|
| 9 (Valve Protection) |
- |
|
|
|
| 10 (Handle) |
- |
|
|
|
| 10 (Foot ring) |
- |
|
|
|
| 10 (Foot ring) |
- |
|
|
|
| 10 (Foot ring) |
- |
|
|
|
| 10.3 (Bung) |
- |
|
|
|
| 14 (Water Capacity) |
- |
|
|
|
| 16 (Pneumatic Leakage Test) |
- |
|
|
|
| 18.1.3 (Root Bend test,) |
- |
|
|
|
| 18.1.3 (Face Bend Test,) |
- |
|
|
|
| 18.1.5 (Minimum Thickness test) |
- |
|
|
|
| 20 (Colour Identification) |
- |
|
|
|
| 10.3 (Bung) |
- |
|
|
|
|
- |
- 2nos
Excluding except material test, Hydrostatic stretch test,RADIOGRAPHIC EXAMINATION (Prepared Test piece needed for Acceptance Test). Test facility for hydrostatic test is limited to 360Kg/cm2 pressure. |
| 14756 |
BIS, Southern Regional Laboratory (SRL)
| None
| IS 6006 (2014) |
Uncoated stress relieved strand for prestressed concrete - Specification (Second Revision) |
- |
Rs 4035/- Excluding Proof Stress and Relaxation Test View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl 5 (Weight) |
- |
|
|
|
| Cl 7 (Tensile Test On UTM) |
- |
|
|
|
| Cl 4 (Length ) |
- |
|
|
|
| Cl 4 (Joints) |
- |
|
|
|
| Cl 4.5 (Workmanship) |
- |
|
|
|
| Clause 5.3, Table-2 (Nominal Diameter of Strand (Seven - Wire Strand) ) |
- |
|
|
|
|
- |
- " 3 mts + 50g
Excluding Strands upto 9.5 mm 7-Ply only,chemical tests and Excl Breaking strength, proof stress, Elongation and stress relaxation tests. |
| 14757 |
BIS, Southern Regional Laboratory (SRL)
| None
| IS 2556 : Part 7 (1995) |
Vitreous sanitary appliances (Vitreous China) - specification: Part 7 specific requirements of accessories for sanitary appliances |
- |
- View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 3 (General requirements-Application of Glazing-IS 2556 (Part 1)) |
- |
|
|
|
| 3 (General requirements-Application of Glazing-IS 2556 (Part 1)) |
- |
|
|
|
| 3 (General requirements-Application of Glazing-IS 2556 (Part 1)) |
- |
|
|
|
| 3 (General requirements-Permissible blemishes or defects (WC apns, Bidets, Squatting pans, Urinals, Partition plates, Pedestals, Short Pedestals and Accessories)-General-Wavy finiah-IS 2556 (Part 1)) |
- |
|
|
|
| 3 (General requirements-Permissible blemishes or defects (WC apns, Bidets, Squatting pans, Urinals, Partition plates, Pedestals, Short Pedestals and Accessories)-Flushing surface and horizontal face of WC pans,iDI lurfaco and horizontal tace of rima of we pans, Squatting pans bidets and urinals-Bubbles and specks-IS 2556 (Part 1)) |
- |
|
|
|
| 3 (General requirements-Permissible blemishes or defects (Wash Basins, Laboratory sinks and drinking fountains)-General-Wavy finiah-IS 2556 (Part 1))) |
- |
|
|
|
| 3 (General requirements-Permissible blemishes or defects (Wash Basins, Laboratory sinks and drinking fountains)-General-Warpages-IS 2556 (Part 1))) |
- |
|
|
|
| 3 (General requirements-Permissible blemishes or defects (Wash Basins, Laboratory sinks and drinking fountains)-General-Dislocations-IS 2556 (Part 1))) |
- |
|
|
|
| 3 (General requirements-Permissible blemishes or defects (Wash Basins, Laboratory sinks and drinking fountains)-Service space top of slab inside of bowl, front of fascis-Spots, blisters and pinholes-IS 2556 (Part 1))) |
- |
|
|
|
| 3 (General requirements-Permissible blemishes or defects (Wash Basins, Laboratory sinks and drinking fountains)-Service space top of slab inside of bowl, front of fascis-Polishing marks-IS 2556 (Part 1))) |
- |
|
|
|
| 3 (General requirements-Permissible blemishes or defects (Wash Basins, Laboratory sinks and drinking fountains)-Face of intrnal, back and side-Spots, blisters and pinholes-IS 2556 (Part 1))) |
- |
|
|
|
| 3 (General requirements-Permissible blemishes or defects (Wash Basins, Laboratory sinks and drinking fountains)-Face of intrnal, back and side-Polishing marks-IS 2556 (Part 1))) |
- |
|
|
|
| 3 (General requirements-Permissible blemishes or defects (Flushing cisterns, Auto cisterns and covers)-General-Warpage-IS 2556 (Part 1))) |
- |
|
|
|
| 3 (General requirements-Permissible blemishes or defects (Flushing cisterns, Auto cisterns and covers)-General-Dislocations-IS 2556 (Part 1))) |
- |
|
|
|
| 3 (General requirements-Permissible blemishes or defects (Flushing cisterns, Auto cisterns and covers)-Visual surface-Spot, blisters and pinholes-IS 2556 (Part 1))) |
- |
|
|
|
| 3 (General requirements-Permissible blemishes or defects (Flushing cisterns, Auto cisterns and covers)-Visual surface-Bubbles and specks-IS 2556 (Part 1))) |
- |
|
|
|
| 3 (General requirements-Permissible blemishes or defects (Flushing cisterns, Auto cisterns and covers)-Visual surface-Polishing marks-IS 2556 (Part 1))) |
- |
|
|
|
| 3 (General requirements-Thickness
IS 2556 (Part 1)) |
- |
|
|
|
| 3 (General requirements-PERFORMANCE REQUIllEMENTS-WARPAGE IS 2556 (Part 1)) |
- |
|
|
|
| 3 (General requirements-PERFORMANCE REQUIllEMENTS-CRAZING IS 2556 (Part 1)) |
- |
|
|
|
| 4 (DIMENSIONS-STOP END CHANNEL WITH OUTLET-Type A
) |
- |
|
|
|
| 4 (DIMENSIONS-STOP END CHANNEL WITH OUTLET-Type B
) |
- |
|
|
|
| 4 (DIMENSIONS-PLAIN CHENNEL-Type A
) |
- |
|
|
|
| 4 (DIMENSIONS-PLAIN CHENNEL-Type B
) |
- |
|
|
|
| 4 (DIMENSIONS-PLAIN CHANNEL WITH SOCKET-Type A
) |
- |
|
|
|
| 4 (DIMENSIONS-PLAIN CHANNEL WITH SOCKET-Type B
) |
- |
|
|
|
| 4 (DIMENSIONS-FOOT REST
) |
- |
|
|
|
| 4 (DIMENSIONS-- FLOOR TRAP) |
- |
|
|
|
| 4 (DIMENSIONS-TYPICAL ILLUSTRATION OF VITRIOUS SHOWER ROSH) |
- |
|
|
|
| 5 (CONSTRUCTION) |
- |
|
|
|
| 6 (FINISH) |
- |
|
|
|
| 4 (DIMENSIONS-- Ovality permissible within the variation allowed for the dimensioN
) |
- |
|
|
|
|
- |
- 2nos |
| 14758 |
BIS, Southern Regional Laboratory (SRL)
| None
| IS 2098 (1997) |
Asbestos cement building boards - Specification (First Revision) |
- |
3300 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 7.1 Table -1 ( TOLERANCES - 1.Tolerance on Length & Width) |
- |
|
|
|
| 7.2 Table -1 (2.Tolerance on Thickness ) |
- |
|
|
|
| 8.4 (TESTS-Water Absorption Test ) |
- |
|
|
|
| 11 (MARKING-Each board shall be stamped or marked by any suitable
method on non weathering side with the following
information: ) |
- |
|
|
|
|
- |
- " 2 nos.
Excl load bearing capacity test |
| 14759 |
BIS, Southern Regional Laboratory (SRL)
| None
| IS 3196 : Part 4 (2001) |
Welded low carbon steel cylinders exceeding 5 litre water capacity for low pressure liquefiable gases - Specification: Part 4 cylinders for toxic and corrosive gases |
- |
- View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 19 (Marking) |
- |
|
|
|
| 4 (Material) |
- |
|
|
|
| 9.3 (Valve Protection) |
- |
|
|
|
| 9.3 (Valve Protection) |
- |
|
|
|
| 10.2 (Foot ring) |
- |
|
|
|
| 14 (Water Capacity) |
- |
|
|
|
| 15 (Hydrostatic test) |
- |
|
|
|
| 4 (Material,Bung) |
- |
|
|
|
| 16 (Pneumatic Leakage Test) |
- |
|
|
|
| 17.2 (Bursting test) |
- |
|
|
|
| 8.4 (Agreed finished Thickness ) |
- |
|
|
|
| 20 (Colour Identification) |
- |
|
|
|
| 19 (Marking) |
- |
|
|
|
| 9.3 (Valve Protection) |
- |
|
|
|
| 14 (Water Capacity) |
- |
|
|
|
| 15 (Hydrostatic test) |
- |
|
|
|
| 16 (Pneumatic Leakage Test) |
- |
|
|
|
| 17.2 (Bursting test) |
- |
|
|
|
| 18.1.3 (Face Bend Test,) |
- |
|
|
|
| 18.1.7 (Macro Examination) |
- |
|
|
|
| 8.4 (Agreed finished Thickness ) |
- |
|
|
|
| 20 (Colour Identification) |
- |
|
|
|
|
- |
- 5
Excluding Excl 1.Hydrostatic stretch test 2.Nicked bend test 3.Radiographic examination Facility for preparation of test specimen not available,Chemical facility not available |
| 14760 |
BIS, Southern Regional Laboratory (SRL)
| None
| IS 1812 (1982) |
Specification for carbon steel wire for the manufacture of wood screws (Second Revision) |
- |
825 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 6.1 ( Tensile Test IS1608(P-1)) |
- |
|
|
|
| 6.3 ( Wrapping Test ) |
- |
|
|
|
| 7 (. SIZE TOLERANCE) |
- |
|
|
|
| 8 ( FREEDOM FROM DEFECTS) |
- |
|
|
|
|
- |
- " 3m + 100g drill.
Excluding chemical facility not available. |