| 14941 |
BIS, Central Laboratory (CL)
| None
| IS 7494 (1981) |
Specification for steel for valves for internal combustion engines (First Revision) |
- |
- View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl. 6.1, 6.2, 6.3, & Table 1 (Carbon- IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
|
|
|
| Cl. 6.1, 6.2, 6.3, & Table 1 (Silicon- IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
|
|
|
| Cl. 6.1, 6.2, 6.3, & Table 1 (Manganese- IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
|
|
|
| Cl. 6.1, 6.2, 6.3, & Table 1 (Sulphur- IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
|
|
|
| Cl. 6.1, 6.2, 6.3, & Table 1 (Phosphorus- IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
|
|
|
| Cl. 6.1, 6.2, 6.3, & Table 1 (Nitrogen- IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
|
|
|
|
- |
- Steel designation as per table 1 may plese be declared Sample size shall be minimum dia> 3mm and thickness > 0.8 mm.; |
| 14942 |
BIS, Southern Regional Laboratory (SRL)
| None
| IS 1554 : Part 2 (1988) |
Specification for pvc insulated (Heavy Duty) electric cables: Part 2 for working voltages from 3.3 kV up to and including 11 kV (Second Revision) |
- |
- View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 3.1 (CONDUCTOR) |
- |
|
|
|
| 3.1.1 (CONDUCTOR) |
- |
|
|
|
| 4.1 (INSULATION) |
- |
|
|
|
| 5.1 (SCREENING) |
- |
|
|
|
| 5.1.1 (Non-magnetic Metallic Tape for SingleCore Unscreened and Unarmoured Cables) |
- |
|
|
|
| 6.1 (FILLERS AND INNER SHEATH) |
- |
|
|
|
| 6.2 (FILLERS AND INNER SHEATH) |
- |
|
|
|
| 7.1 (ARMOURING) |
- |
|
|
|
| 7.2 (ARMOURING) |
- |
|
|
|
| 8.1 (OUTER SHEATH) |
- |
|
|
|
| 9.1 (CONDUCTOR) |
- |
|
|
|
| 9.2 (CONDUCTOR) |
- |
|
|
|
| 10.1 (CONDUCTOR SCREENING) |
- |
|
|
|
| 11.1 (INSULATION) |
- |
|
|
|
| 11.2 (INSULATION : Thickness of Insulation) |
- |
|
|
|
| 11.3 (INSULATION : Tolerance on Thickness of Insulation) |
- |
|
|
|
| 11.4 (INSULATION : Application of Insulation) |
- |
|
|
|
| 12.1 (INSULATION SCREENING) |
- |
|
|
|
| 12.2 (INSULATION SCREENING) |
- |
|
|
|
| 12.3 (INSULATION SCREENING) |
- |
|
|
|
| 12.4 (INSULATION SCREENING) |
- |
|
|
|
| 13.1 (CORE IDENTIFICATION) |
- |
|
|
|
| 13.1.1 (CORE IDENTIFICATION) |
- |
|
|
|
| 14.1 (LAYING UP OF CORES) |
- |
|
|
|
| 15.1 (INNER SHEATH (COMMON COVERING)) |
- |
|
|
|
| 15.2 (INNER SHEATH (COMMON COVERING)) |
- |
|
|
|
| 15.3 (INNER SHEATH (COMMON COVERING)) |
- |
|
|
|
| 15.4 (INNER SHEATH (COMMON COVERING) : Thickness of Inner Sheath) |
- |
|
|
|
| 15.4.1 (INNER SHEATH (COMMON COVERING) : Thickness of Inner Sheath) |
- |
|
|
|
| 16.1.1 (ARMOURING : Application) |
- |
|
|
|
| 16.1.2 (ARMOURING : Application) |
- |
|
|
|
| 16.1.3 (ARMOURING : Direction of lay ) |
- |
|
|
|
| 16.1.4 (ARMOURING : Application) |
- |
|
|
|
| 16.2.1 (ARMOURING : Type of Armour) |
- |
|
|
|
| 16.2.2 (ARMOURING : Type of Armour) |
- |
|
|
|
| 16.3 (Armouring : Dimensions -Wire Diameter) |
- |
|
|
|
| 16.3 (Armouring : Dimensions -Formed wire ) |
- |
|
|
|
| 16.4 (ARMOURING : Joints) |
- |
|
|
|
| 16.5 (ARMOURING : Resistance) |
- |
|
|
|
| 13.6 a) (ARMOURING: Tensile Strength) |
- |
|
|
|
| 13.6 b) (ARMOURING: Elongation ) |
- |
|
|
|
| 13.6 c) (ARMOURING: Torsion Test (For round wire ) ) |
- |
|
|
|
| 13.6 d) (ARMOURING: Winding Test(For formed wire)) |
- |
|
|
|
| 13.6 e) (ARMOURING: Uniformity of zinc coating) |
- |
|
|
|
| 13.6 f) (ARMOURING: Mass of zinc coating ) |
- |
|
|
|
| 13.6 g) (ARMOURING: Resistivity) |
- |
|
|
|
| 17.1 (OUTER SHEATH) |
- |
|
|
|
| 17.2 (OUTER SHEATH : colour ) |
- |
|
|
|
| 17.3.1 (Thickness of Outer Sheath : Unarmoured Cables) |
- |
|
|
|
| 17.3.2 (Thickness of Outer Sheath : Armoured Cables) |
- |
|
|
|
| 18.1 a) 1) (Tests on Conductor : Annealing test (for copper)) |
- |
|
|
|
| 18.1 a) 2) (Tensile test (for aluminium) - Before stranding ) |
- |
|
|
|
| 18.1 a) 2) (Tensile test (for aluminium) - After stranding ) |
- |
|
|
|
| 18.1 a) 3) (Tests on Conductor : Wrapping test ( for aluminium)) |
- |
|
|
|
| 18.1 a)4) (Tests on conductor : Conductor resistance test - Main conductor ) |
- |
|
|
|
| 18.1 a)4) (Resistance test - Neutral conductor ) |
- |
|
|
|
| 18.1 d) 1) (Phyaical tests for insulation : Tensile Test) |
- |
|
|
|
| 18.1 d) 1) (Phyaical tests for insulation : Elongation ) |
- |
|
|
|
| 18.1 d) 1) (Physical tests for sheath : Tensile stregth ) |
- |
|
|
|
| 18.1 d) 1) (Physical tests for sheath : Elongation ) |
- |
|
|
|
| 18.1 d) 2) (Phyaical tests for insulation- Ageing in air Oven : Tensile Test) |
- |
|
|
|
| 18.1 d) 2) (Phyaical tests for insulation - Ageing in air oven : Elongation ) |
- |
|
|
|
| 18.1 d) 2) (Phyaical tests for insulation - Ageing in air Oven : Tensile Variation ) |
- |
|
|
|
| 18.1 d) 2) (Phyaical tests for insulation- Ageing in air oven : Elongation Variation ) |
- |
|
|
|
| 18.1 d) 2) (Physical tests for outer sheath- Ageing in air oven : Tensile stregth ) |
- |
|
|
|
| 18.1 d) 2) (Physical tests for outer sheath -Ageing in air oven : Elongation ) |
- |
|
|
|
| 18.1 d) 2) (Physical tests for outer sheath- Ageing in air oven : Tensile stregth Variation ) |
- |
|
|
|
| 18.1 d) 2) (Physical tests for outer sheath -Ageing in air oven : Elongation Variation ) |
- |
|
|
|
| 18.1 d) 3) (Phyaical tests for insulation : Shrinkage ) |
- |
|
|
|
| 18.1 d) 3) (Phyaical tests for insulation : Shrinkage - Crack observed ) |
- |
|
|
|
| 18.1 d) 3) (Phyaical tests for Sheath : Shrinkage ) |
- |
|
|
|
| 18.1 d) 3) (Phyaical tests for Sheath : Shrinkage - Crack observed ) |
- |
|
|
|
| 18.1 d) 4) (Hot deformation : Insulation ) |
- |
|
|
|
| 18.1 d) 4) (Hot deformation : Sheath ) |
- |
|
|
|
| 18.1 d) 5) ( Loss of mass in air oven- Insulation ) |
- |
|
|
|
| 18.1 d) 5) ( Loss of mass in air oven- sheath ) |
- |
|
|
|
| 18.1 d) 6) (Heat shock test- Insulation ) |
- |
|
|
|
| 18.1 d) 6) (Heat shock test- sheath ) |
- |
|
|
|
| 18.1 d) 7) (Thermal stability- insulation ) |
- |
|
|
|
| 18.1 d) 7) (Thermal stability- Sheath ) |
- |
|
|
|
| 18.1 d) 8) (Water absorption (gravimetric)(for insulation, where applicable)) |
- |
|
|
|
| 18.1 e) (Insulation resistance test : Volume Resistivity ) |
- |
|
|
|
| 18.1 e) (Insulation resistance test : IR Constant ) |
- |
|
|
|
| 19.8 (Flammability test) |
- |
|
|
|
| 20.1 (IDENTIFICATION : Manufacturer's Identification) |
- |
|
|
|
| 20.2 (IDENTIFICATION : Cable Identification) |
- |
|
|
|
| 20.3 (IDENTIFICATION : Cable Code) |
- |
|
|
|
| 19.8 (Flammability test) |
- |
|
|
|
| 13.6 f) (ARMOURING: Mass of zinc coating ) |
- |
|
|
|
|
- |
- " 15 m
Excluding partial discharge , bend, Dielectric Power factor , heating cycle , implse withstand applicable to cable with screened core i.e for 6.35//11 Kv cable ,High voltage test above 3.3/3.3kV, Excluding C1 & C2 Category |
| 14943 |
BIS, Bengaluru Branch Laboratory (BNBL)
| None
| IS 15111 : PART 1 AND PART 2 (2002) |
Self ballasted lamps for general lighting services: Part 1 safety requirements |
Up to 26 W, Up to 250 V, B22d/E27/E14 cap |
Rs.39410/- View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 6.1 (Marking) |
- |
|
|
|
| 6.2 (Marking) |
- |
|
|
|
| 6.3 (Marking) |
- |
|
|
|
| 6.4 (BIS Certification Marking) |
- |
|
|
|
| 7 (Interchangeability
) |
- |
|
|
|
| 8 (Protection against electric shock) |
- |
|
|
|
| 9.1 (INSULATION RESISTANCE AND ELECTRIC
STRENGTH After HUMIDIT’Y TREATMENT) |
- |
|
|
|
| 9.2 (Insulation Resistance) |
- |
|
|
|
| 9.3 (Electric Strength) |
- |
|
|
|
| 10 (Mechanical strength test
) |
- |
|
|
|
| 11 (Cap Temperature rise test
) |
- |
|
|
|
| 12 (Resistance to heat) |
- |
|
|
|
| 13 (Resistance to Flame and Ignition) |
- |
|
|
|
| 14 (Fault Conditions) |
- |
|
|
|
|
- |
- - |
| 14944 |
BIS, Central Laboratory (CL)
| None
| IS 12931 (1990) |
Atrazine WP - Specification |
- |
Rs.3650.00 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 3.2 (Description) |
- |
|
|
|
| 3.3 Table 1 i (Atrazine Content) |
- |
|
|
|
| 3.3 Table 1 ii (Sieving requirements material passing through 75 micron IS sieve) |
- |
|
|
|
| 3.3 Table 1 iii (Suspensibility) |
- |
|
|
|
| 3.3 Table 1 iv (Acidity/Alkalinity) |
- |
|
|
|
| 3.3 Table 1 v (Wettability) |
- |
|
|
|
|
- |
- - |
| 14945 |
BIS, Central Laboratory (CL)
| None
| IS 848 (2006) |
Synthetic resin adhesives for plywood (Phenolic And Aminoplastic) - Specification (Second Revision) |
BWP/ BWR/ MR |
Rs 1400/- View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4 Table (i) (BWP (BOiling WaterProof)) |
- |
|
|
|
| 4 Table (i) (BWR (Boiling Water Resistant)) |
- |
|
|
|
| 4 Table (i) (MR (Moisture Ressistant)) |
- |
|
|
|
| 7.4 (Acidity and Alkalinity ( pH)) |
- |
|
|
|
| 5,7.4 (Keeping Quality (Resistance to heat Polymerization)) |
- |
|
|
|
|
- |
- - |
| 14946 |
BIS, Central Laboratory (CL)
| None
| IS 5872 (1990) |
Cold rolled steel strips (Box Strappings) - Specification |
- |
6050 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl 6 (UTM) |
- |
|
|
|
| Cl 7 (Bending To Both Side At 90°, Then Straight) |
- |
|
|
|
| Cl 9 (Workmanship) |
- |
|
|
|
| Cl 10 (Width & Thickness) |
- |
|
|
|
| Cl 11 (Workmanship) |
- |
|
|
|
| 5.0 & 5.1 , Table 1 & 2 (Carbon) |
- |
|
|
|
| 5.0 & 5.1 , Table 1 & 2 (Manganese) |
- |
|
|
|
| 5.0 & 5.1 , Table 1 & 2 (Sulphur) |
- |
|
|
|
| 5.0 & 5.1 , Table 1 & 2 (Phosphorus) |
- |
|
|
|
| 5.0 & 5.1 , Table 1 & 2 (Niobium) |
- |
|
|
|
| 5.0 & 5.1 , Table 1 & 2 (Vanadium) |
- |
|
|
|
| 5.0 & 5.1 , Table 1 & 2 (Titanium) |
- |
|
|
|
| 5.0 & 5.1 , Table 1 & 2 (Boron) |
- |
|
|
|
| 5.0 & 5.1 , Table 1 & 2 (Micro Alloying Elements) |
- |
|
|
|
|
- |
- Sample size shall be minimum dia> 3mm and thickness > 0.8 mm;
excluding -; Corrosion Resistance test (CL 12) |
| 14947 |
BIS, Northern Regional Laboratory (NRL)
| None
| IS 1566 (1982) |
Specification for hard - Drawn steel wire fabric for concrete reinforcement (Second Revision) |
- |
Rs 300/- + mat test as per IS:432(Pt 2) View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 6 (DIMENSIONS) |
- |
|
|
|
| 7 (SIZES OF SHEETS ‘OR ROLLS) |
- |
|
|
|
| 8 (MASS) |
- |
|
|
|
| 9.2 (Tolerance on Size of Mesh) |
- |
|
|
|
| 9.3 (Tolerance on Size of Sheet) |
- |
|
|
|
| 9.4 (Tolerance on Mass of Fabric) |
- |
|
|
|
| 10 (MECHANICAL PROPERTIES) |
- |
|
|
|
| 11.2 (Tensile Test) |
- |
|
|
|
| 11.3 (Reverse Bend Test) |
- |
|
|
|
|
- |
- Test facility is complete |
| 14948 |
BIS, Northern Regional Laboratory (NRL)
| None
| IS 4397 (1999) |
Cold - Rolled carbon steel strips for ball and roller bearing cages retainers - Specification (Second Revision) |
- |
- View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4 (Freedom from defects ) |
- |
|
|
|
| 8 ( Bend Test ) |
- |
|
|
|
| 9 (Hardness-IS 1500: Pt 1) |
- |
|
|
|
| 14 ( ROLLING TOLERANCES) |
- |
|
|
|
| Cl. 5.2, 6.1, 6.1.1, 6.2 Table 1 (Carbon- IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
|
|
|
| Cl. 5.2, 6.1, 6.1.1, 6.2 Table 1 (Manganese- IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
|
|
|
| Cl. 5.2, 6.1, 6.1.1, 6.2 Table 1 (Phosphorus- IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
|
|
|
| Cl. 5.2, 6.1, 6.1.1, 6.2 Table 1 (Sulphur- IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
|
|
|
| Cl. 5.2, 6.1, 6.1.1, 6.2 Table 1 (Aluminium- IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
|
|
|
| Cl. 5.2, 6.1, 6.1.1, 6.2 Table 1 (Silicon- IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
|
|
|
| Cl. 5.2, 6.1, 6.1.1, 6.2 Table 1 (Nitrogen- IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
|
|
|
| Cl. 5.2, 6.1, 6.1.1, 6.2 Table 1 (Chromium- IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
|
|
|
| Cl. 5.2, 6.1, 6.1.1, 6.2 Table 1 (Nickel- IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
|
|
|
| Cl. 5.2, 6.1, 6.1.1, 6.2 Table 1 (Molybdenum- IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
|
|
|
| Cl. 5.2, 6.1, 6.1.1, 6.2 Table 1 (Copper- IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
|
|
|
| Cl. 5.2, 6.1, 6.1.1, 6.2 Table 1 (Niobium- IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
|
|
|
| Cl. 5.2, 6.1, 6.1.1, 6.2 Table 1 (Vanadium- IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
|
|
|
| Cl. 5.2, 6.1, 6.1.1, 6.2 Table 1 (Titanium- IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
|
|
|
| Cl. 5.2, 6.1, 6.1.1, 6.2 Table 1 (Boron- IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
|
|
|
|
- |
- Excluding Micro examination, Cupping test. |
| 14949 |
BIS, Bengaluru Branch Laboratory (BNBL)
| None
| IS 11673 : Part 2 (2019) |
Sodium hypochlorite solution - Specification: Part 2 water treatment use (Second Revision) |
- |
Rs.18022/ View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl. 4.3, Table-1, Sr.no. 1 (Relative density (at 25o/25oC)) |
- |
|
|
|
| Cl. 4.3, Table-1, Sr.no. 2 (Available Chlorine(as Cl2)) |
- |
|
|
|
| Cl. 4.3, Table-1, Sr.no. 3 (Total Chlorine(as Cl2)) |
- |
|
|
|
| Cl. 4.3, Table-1, Sr.no. 4 (Free alkali( as NaOH),) |
- |
|
|
|
| Cl. 4.3, Table-1, Sr.no. 5 (Free Sodium Carbonate (as Na2CO3)) |
- |
|
|
|
| Cl. 4.3, Table-1, Sr.no. 6 (Iron (as Fe)) |
- |
|
|
|
| Cl. 4.3, Table-1, Sr.no. 7 (Sodium Chlorate ( as NaClO3),) |
- |
|
|
|
| Cl. 4.3, Table-1, Sr.no. 8 (Lead (as Pb)) |
- |
|
|
|
| Cl. 4.3, Table-1, Sr.no. 9 (Arsenic (as As)) |
- |
|
|
|
| Cl. 4.3, Table-1, Sr.no. 11 (Manganese (as Mn)) |
- |
|
|
|
| Cl. 4.3, Table-1, Sr.no. 12 (Total chromium (as Cr)) |
- |
|
|
|
| Cl. 4.3, Table-1, Sr.no. 11 (Manganese (as Mn)) |
- |
|
|
|
| Cl. 4.3, Table-1, Sr.no. 12 (Total chromium (as Cr)) |
- |
|
|
|
| Cl. 4.3, Table-1, Sr.no. 13 (Cadmium (as Cd)) |
- |
|
|
|
| Cl. 4.3, Table-1, Sr.no. 14 (Selenium (as Se)) |
- |
|
|
|
| Cl. 4.3, Table-1, Sr.no. 10 (Mercury (as Hg)) |
- |
|
|
|
|
- |
- Complete for chemical section. |
| 14950 |
BIS, Southern Regional Laboratory (SRL)
| None
| IS 14491 (1997) |
Low carbon high strength cold rolled steel sheets and coils for cold forming - Specification |
- |
- View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 8.2 (Tensile Test-1608:Part 1) |
- |
|
|
|
| 8.2, Table 3 (i)Yield Strength, Mpa) |
- |
|
|
|
| 8.2, Table 3 (ii) Tensile Strength, Mpa) |
- |
|
|
|
| 8.2, Table 3 (iii)Elongation, %) |
- |
|
|
|
| 8.4, Table 3 (Bend) |
- |
|
|
|
| 9.5 (SURFACE CONDITION AND FINISH) |
- |
|
|
|
| 10 (FREEDOM FROM DEFECTS) |
- |
|
|
|
| 11 ( DIMENSIONS AND DIMENSIONAL TOLERANCES ) |
- |
|
|
|
|
- |
- " mech - 2 x 500 mm
Excluding except chemical tests |
| 14951 |
BIS, Central Laboratory (CL)
| None
| IS 13801 (2013) |
Chequered Cement Concrete Tiles - |
- |
Rs.9710/- View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl 12.1 (Concavity & Convexity ) |
- |
|
|
|
| Cl 12.3 (Shall not exceed 1 percent of the length of the edge.) |
- |
|
|
|
| Cl 12.4 (Water absorption) |
- |
|
|
|
| Cl 11 (Finish) |
- |
|
|
|
| (Cl 7, 8 &9) (Length, Breadth, Thickness, Difference in length of side between the longest side and shorterst side in the sample shall not exceed 1 mm, Half tiles, Difference in Thickness between the thickest and thinnest tile in the sample shall not exceed 10 percent of minimum thickness, Depth of chequred groove, Thickness of wearing layer.) |
- |
|
|
|
| (Cl 7, 8 &9) (Length, Breadth, Thickness, Difference in length of side between the longest side and shorterst side in the sample shall not exceed 1 mm, Half tiles, Difference in Thickness between the thickest and thinnest tile in the sample shall not exceed 10 percent of minimum thickness, Depth of chequred groove, Thickness of wearing layer.) |
- |
|
|
|
| Cl 12.5 (Wet transverse strength) |
- |
|
|
|
|
- |
- Not pertains to chemical.;
excluding -Resistance of wear |
| 14952 |
BIS, Central Laboratory (CL)
| None
| IS 15647 (2006) |
Hot rolled steel narrow width strip for welded tubes and pipes |
- |
Rs.9900/- View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl 8 (UTM) |
- |
|
|
|
| Cl 9 (Press) |
- |
|
|
|
| Cl 11 (Workmanship) |
- |
|
|
|
| Cl 12 (Length, Width & Thickness) |
- |
|
|
|
| Cl 13 (Workmanship) |
- |
|
|
|
|
- |
- Sample size shall be minimum dia> 3mm and thickness > 0.8 mm; |
| 14953 |
BIS, Southern Regional Laboratory (SRL)
| None
| IS 6529 (1996) |
Stainless steel blooms, billets and slabs for forging - Specification (First Revision) |
- |
- View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 6 (Freedom from defects) |
- |
|
|
|
| 9 (Hardness) |
- |
|
|
|
| 10 (Dimensional Tolerances) |
- |
|
|
|
|
- |
- " mech - 2 x 500 mm
Excluding except chemical tests |
| 14954 |
BIS, Central Laboratory (CL)
| None
| IS 12981 (1991) |
Common salt - Iron fortified - Specification |
- |
Rs.6710/- View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| CL 3.1 (Description ) |
- |
|
|
|
| CL 3.2 (Moisture) |
- |
|
|
|
| CL 3.3, Annex A of IS 253 : 1985 (Particle Size) |
- |
|
|
|
| Table 1 (i), Annex A, Annex IS 253 :
1985
A-4 (Water insoluble matter) |
- |
|
|
|
| Table 1 (vii), Annex A-3 (pH of 5 percent aqueous solution) |
- |
|
|
|
| Table 1 (vii), Annex A-4 (Phosphates ( as PO4 )) |
- |
|
|
|
| Table 1 (iii), IS 253 :
1985
A-6 (Matter insoluble in dilute hydrochloric acid.) |
- |
|
|
|
|
- |
- - |
| 14955 |
BIS, Western Regional Laboratory (WRL)
| None
| IS 13428 (2024) |
PACKAGED NATURAL MINERAL WATER - SPECIFICATION Third Revision |
- |
19200 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 6.2 Table-1 vi (pH) |
- |
|
|
|
| 6.2 Table-1 v (Total dissolved solids) |
- |
|
|
|
| 6.2 Table-1 iv (Turbidity) |
- |
|
|
|
| 6.2 Table-1 iii (Taste) |
- |
|
|
|
| 6.2 Table-1 ii (Odour) |
- |
|
|
|
| 6.1.8 (Vibrio parahemolyticus) |
- |
|
|
|
| 6.1.8 (Vibrio cholera ) |
- |
|
|
|
| 6.1.7 (Shigella) |
- |
|
|
|
| 6.1.7 (Salmonella ) |
- |
|
|
|
| 6.1.6 (Yeast and Mould ) |
- |
|
|
|
| 6.1.5 (Pseudomonas Aeruginosa ) |
- |
|
|
|
| 6.1.4 (Sulphite Reducing Anaerobes ) |
- |
|
|
|
| 6.1.3 (Staphylococcus Aureus) |
- |
|
|
|
| 6.1.3 (Faecal Streptococci ) |
- |
|
|
|
| 6.1.2 (Coliform , bacteria) |
- |
|
|
|
| 6.1.1 (Escherichia coli(or thermotolerant bacteria)) |
- |
|
|
|
| 6.2 Table-2 i (Nitrate (as NO3)) |
- |
|
|
|
| 6.2 Table-2 ii (Nitrite (as NO2)) |
- |
|
|
|
| 6.2 Table-2 iv (Manganese (as Mn)) |
- |
|
|
|
| 6.2 Table-2 v (Copper (as Cu)) |
- |
|
|
|
| 6.2 Table-2 vii (Flouride (as F)) |
- |
|
|
|
| 6.2 Table-2 viii (Barium (as Ba)) |
- |
|
|
|
| 6.2 Table-2 ix (Antimony (as Sb)) |
- |
|
|
|
| 6.2 Table-2 x (Borates (as B)) |
- |
|
|
|
| 6.2 Table-2 xi (Silver (as Ag)) |
- |
|
|
|
| 6.2 Table-2 xii (Chloride (as Cl)) |
- |
|
|
|
| 6.2 Table-2 xiii (Sulphate (as SO4),) |
- |
|
|
|
| 6.2 Table-2 xiv (Magnesium (as Mg)) |
- |
|
|
|
| 6.2 Table-2 xv (Calcium (as Ca)) |
- |
|
|
|
| 6.2 Table-2 xvi (Sodium (as Na)) |
- |
|
|
|
| 6.2 Table-2 xvii (Alkalinity (as HCO3)) |
- |
|
|
|
| 6.2 Table-2 xviii (Selenium (as Se)) |
- |
|
|
|
| 6.2 Table-3 v (Mercury (as Hg)) |
- |
|
|
|
| 6.2 Table-3 ii (Cadmium (as Cd)) |
- |
|
|
|
| 6.2 Table-3 i (Arsenic (as As)) |
- |
|
|
|
| 6.2 Table-3 vi (Lead (as Pb) |
- |
|
|
|
| 6.2 Table-3 iv (Chromium (as Cr)) |
- |
|
|
|
| 6.2 Table-3 vii (Nickel (as Ni)) |
- |
|
|
|
|
- |
- Test facility not available for following:
1. Cyanide 2.RAR |
| 14956 |
BIS, Central Laboratory (CL)
| None
| IS 3829 : Part 2 (1978) |
Specification for steam sterilizers: Part 2 horizontal cylindrical high speed steam sterilizers, pressure type (First Revision) |
- |
Please see remarks. View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4.1 (Shape) |
- |
|
|
|
| 4.2 (Size) |
- |
|
|
|
| 6.1 (as per Cl. 6.1) |
- |
|
|
|
| 6.2 (as per Cl. 6.2) |
- |
|
|
|
| 6.2.1 (as per Cl. 6.2.1) |
- |
|
|
|
| 6.2.2 (as per Cl. 6.2.2) |
- |
|
|
|
| 6.2.3.1 (as per Cl. 6.2.3.1) |
- |
|
|
|
| 6.2.4 (as per Cl. 6.2.4) |
- |
|
|
|
| 6.3 (Door- as per Cl. 6.3) |
- |
|
|
|
| 6.3.2 (Door Gasket- as per Cl. 6.3.2) |
- |
|
|
|
| 6.3.3 (Adjustment- as per Cl. 6.3.3) |
- |
|
|
|
| 7.1.1 (Operating Valve- as per Cl. 7.1.1) |
- |
|
|
|
| 7.1.1.1 (as per Cl. 7.1.1.1) |
- |
|
|
|
| 7.1.2 (Exhaust time- Cl. 7.1.2) |
- |
|
|
|
| 7.1.3.1 (as per Cl. 7.1.3.1) |
- |
|
|
|
| 7.1.4 (vaccum breaker- Cl. 7.1.4) |
- |
|
|
|
| 7.1.5 (Drying system-Cl. 7.1.5) |
- |
|
|
|
| 7.1.6 (Baffle- Cl. 7.1.6) |
- |
|
|
|
| 7.1.7 (Chamber drain- Cl. 7.1.7) |
- |
|
|
|
| 7.1.7.1 (Plug Screen- Cl. 7.1.7.1) |
- |
|
|
|
| 7.1.7.2 (Thermometer- Cl. 7.1.7.2) |
- |
|
|
|
| 7.1.8 (Gauges- Cl. 7.1.8) |
- |
|
|
|
| 8 (Hydrostatic Test- as per Cl 8.1, 8.1.1 & 8.2) |
- |
|
|
|
|
- |
- - |
| 14957 |
BIS, Bengaluru Branch Laboratory (BNBL)
| None
| IS 398 : Part 4 (1994) |
Aluminium conductors for overhead transmission purposes: Part 4 aluminium alloy stranded conductors (Aluminium - Magnesium - Silicon Type) - Specification (Third Revision) |
- |
Please see remarks View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 6.1 (Freedom from Defects) |
- |
|
|
|
| 7.1 Table-1 (Dimensional measurement of wires) |
- |
|
|
|
| 7.2.2 Table-2, Table-4 (Calculated resistance of Stranded Conductor) |
- |
|
|
|
| 8.1 (Joints in wires-Conductors Containing Seven Wires) |
- |
|
|
|
| 8.2 (Joints in wires-Conductors Containing More Than Seven Wires) |
- |
|
|
|
| 9.1 (Stranding) |
- |
|
|
|
| 9.2 Table 3 (Lay Ratio of stranded conductors) |
- |
|
|
|
| 9.3 (Direction of Lay) |
- |
|
|
|
| 9.4 (Multiple layers of wires) |
- |
|
|
|
| 11 (Packing and Marking) |
- |
|
|
|
| 12.2 Table 1 (Breaking Load Test- Before Stranding) |
- |
|
|
|
| 12.2 Table 1 (Breaking Load Test- After Stranding) |
- |
|
|
|
| 12.3 Table 1 (Elongation Test- Before Stranding) |
- |
|
|
|
| 12.3 Table 1 (Elongation Test- After Stranding) |
- |
|
|
|
| 12.4 Table 1 (Resistance of Aluminium wire) |
- |
|
|
|
|
- |
- Complete |
| 14958 |
BIS, Central Laboratory (CL)
| None
| IS 15558 (2005) |
Mini domestic water heater for use with LPG - Specification |
- |
13513 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4.1.1 (Construction) |
- |
|
|
|
| 4.1.2 (Construction) |
- |
|
|
|
| 4.1.3 (Construction) |
- |
|
|
|
| 4.1.4 (Construction) |
- |
|
|
|
| 4.1.5 (Construction) |
- |
|
|
|
| 4.1.6 (Construction) |
- |
|
|
|
| 4.1.7 (Construction) |
- |
|
|
|
| 4.1.8 (Construction) |
- |
|
|
|
| 4.1.10 (Construction) |
- |
|
|
|
| 4.1.11 (Construction) |
- |
|
|
|
| 4.1.12 (Construction) |
- |
|
|
|
| 5.2 (Materials) |
- |
|
|
|
| 5.3 (Materials) |
- |
|
|
|
| 5.4 (Materials) |
- |
|
|
|
| 6.2 (Connections) |
- |
|
|
|
| 6.3 (Connections) |
- |
|
|
|
| 6.4 (Connections) |
- |
|
|
|
| 6.5 (Connections) |
- |
|
|
|
| 6.6 (Gas Inlet Connections) |
- |
|
|
|
| 6.6 (Gas Inlet Connections) |
- |
|
|
|
| 6.6 (Gas Inlet Connections) |
- |
|
|
|
| 6.6 (Gas Inlet Connections) |
- |
|
|
|
| 6.6 (Gas Inlet Connections) |
- |
|
|
|
| 6.6 (Gas Inlet Connections) |
- |
|
|
|
| 7 (Flame Visibility) |
- |
|
|
|
| 8 (Gas Taps) |
- |
|
|
|
| 9 (Flame Failure Device) |
- |
|
|
|
| 10 (Ignition Device) |
- |
|
|
|
| 11 (Protection Against Accidental Overheating) |
- |
|
|
|
| 12 (Water Rate Adjuster) |
- |
|
|
|
| 14 (Gas Soundness) |
- |
|
|
|
| 15 (Water Soundness) |
- |
|
|
|
| 16 (Thermal Efficiency) |
- |
|
|
|
| 16 (Thermal Efficiency) |
- |
|
|
|
| 17 (Combustion) |
- |
|
|
|
| 18 (Gas Consumption) |
- |
|
|
|
| 19.1 (Ignition and flame travel) |
- |
|
|
|
| 19.2 (Ignition and flame travel) |
- |
|
|
|
| 19.3 (Ignition and flame travel) |
- |
|
|
|
| 20 (Flame Stability) |
- |
|
|
|
| 21 (Noise Control) |
- |
|
|
|
| 22 (Flash Back) |
- |
|
|
|
| 23 (Resistance to Draught) |
- |
|
|
|
| 24 (Fire Hazard And Limiting Temperature ) |
- |
|
|
|
| 24 (Fire Hazard And Limiting Temperature) |
- |
|
|
|
| 25 (Time For Temperature Rise) |
- |
|
|
|
| 26 (Hot Water Output Test) |
- |
|
|
|
|
- |
- - |
| 14959 |
BIS, Central Laboratory (CL)
| None
| IS 758 (1988) |
Specification for cotton gauze, absorbent, non-sterilized (fourth revision) |
- |
Rs 2400/- View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 3.1,Table 1,Sr.No.vii
IS : 1390 (pH value) |
- |
|
|
|
| 3.1,Table 1,Sr.No.viii
IS : 1383 (Scouring Loss) |
- |
|
|
|
|
- |
- - |
| 14960 |
BIS, Central Laboratory (CL)
| None
| IS 3564 (1995) |
Hydraulically Regulated Door Closers -Specification |
- |
Please see remarks. View breakup
Rs. 11400.00/- and testing charges as per referred Iss
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| B-1.5 (d) Endurance Test) |
- |
|
|
|
| B-1.4 (c) Performance Requirements) |
- |
|
|
|
| B-1.3 (b) Surface) |
- |
|
|
|
| B-1.2 (a) Visual Inspection) |
- |
|
|
|
| 8 (Essential Requirements) |
- |
|
|
|
| 9 (Finish) |
- |
|
|
|
|
- |
- - |
| 14961 |
BIS, Southern Regional Laboratory (SRL)
| None
| IS 6967 (1973) |
Specification for steels for electrically welded round link chains |
- |
- View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4 ( FREEDOM FROM DEFECTS) |
- |
|
|
|
| 7 ( HARDNESS) |
- |
|
|
|
| 8, Table 3 (Tensile Test-1608:Part 1) |
- |
|
|
|
| 8, Table 3 (Yield Strength, Mpa) |
- |
|
|
|
| 8, Table 3 (Elongation, %) |
- |
|
|
|
| 11 (DIMENSIONAL TOLERANCES) |
- |
|
|
|
|
- |
- " mech - 2 x 500 mm
Excluding except Hardenability, Grain size and Chemical tests |
| 14962 |
BIS, Southern Regional Laboratory (SRL)
| None
| IS 12367 (1988) |
Specification for cold - Rolled carbon steel strips/coils for manufacture of welded tubes |
- |
- View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 5 (Tensile Test-1608:Part 1) |
- |
|
|
|
| 5.2.1, Table 3 (ii)Ultimate Tensile Strength, Mpa) |
- |
|
|
|
| 5.2.1, Table 3 (iii)Elongation, %) |
- |
|
|
|
| 12 (Dimensions ) |
- |
|
|
|
| 11 (Freedom from Defects) |
- |
|
|
|
| 5.2.1, Table 3 (iv) Hardness, HBW) |
- |
|
|
|
|
- |
- " 2 x 500 mm
Excluding except reverse bend test, cupping test, strain -ageing embrittlement test and chemical tests |
| 14963 |
BIS, Western Regional Laboratory (WRL)
| None
| IS 5168 (2018) |
Glass feeding bottles - Specification (First Revision) |
- |
Rs. 6100.00 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl 4 (Types) |
- |
|
|
|
| Cl 5.2 (Description) |
- |
|
|
|
| Cl 5.3 (Capacity) |
- |
|
|
|
| Cl 5.5 (Scale and Graduations) |
- |
|
|
|
| Cl 5.7 (Thermal Shock Resistance) |
- |
|
|
|
| 5.8 (Migration of Heavy and toxic Elements) |
- |
|
|
|
|
- |
- - |
| 14964 |
BIS, Bengaluru Branch Laboratory (BNBL)
| None
| IS 11673 : Part 1 (2019) |
Sodium hypochlorite solution - Specification: Part 1 household and industrial use (Second Revision) |
Household and Industrial Use |
11900 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl. No. 5.1 (Description Grade 1 & 2) |
- |
|
|
|
| Cl. No. 5.2 (Keeping quality- available chlorine( table no. 1, cl 5.3, Annex B), Grade 1 & 2) |
- |
|
|
|
| Cl. No. 5.3, table no. 1, Sl no. 1 (Relative density, Grade 1, Annex -A) |
- |
|
|
|
| Cl. No. 5.3, table no. 1, Sl no. 2 (Available chlorine (as Clâ‚‚), Grade 1, Annex B) |
- |
|
|
|
| Cl. No. 5.3, table no. 1, Sl no. 3 (Total chlorine (as Clâ‚‚), Grade 1, Annex C) |
- |
|
|
|
| Cl. No. 5.3, table no. 1, Sl no. 4 (Free alkali (as NaOH), Grade 1, Annex D) |
- |
|
|
|
| Cl. No. 5.3, table no. 1, Sl no. 5 (Free sodium carbonate (as Na₂CO₃), Grade 1, Annex E) |
- |
|
|
|
| Cl. No. 5.3, table no. 1, Sl no. 6 (Iron (as Fe), Grade 1, Annex F) |
- |
|
|
|
| Cl. No. 5.3, table no. 1, Sl no. 6 (Iron (as Fe), Grade 1, Annex F) |
- |
|
|
|
| Cl. No. 5.3, table no. 1, Sl no. 7 (Sodium chlorate (as NaClO₃), Grade 1, Annex G) |
- |
|
|
|
|
- |
- Complete for chemical section. |
| 14965 |
BIS, Northern Regional Laboratory (NRL)
| None
| IS 1537 (1976) |
Specification for vertically cast iron pressure pipes for water, gas and sewage (First Revision) |
- |
Rs. 3972/- (for flanged ends only) + materials as per View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 3.1 , 6 of IS 210 ( The composition of cast iron shall be left to the
discretion of the manufacturer) |
- |
|
|
|
| 4.1 (Tensile Strength) |
- |
|
|
|
| 4.2 (Hardness test) |
- |
|
|
|
| 6.1 (Hydrostatic test) |
- |
|
|
|
| 7.1 & Table 2 (DE) |
- |
|
|
|
| 7.1 & Table 2 (DI) |
- |
|
|
|
| 7.1 & Table 2 (P) |
- |
|
|
|
| 7.1 & Table 2 (g) |
- |
|
|
|
| 7.1 & Table 2 (h) |
- |
|
|
|
| 7.1 & Table 2 (DC) |
- |
|
|
|
| 7.1 & Table 2 (c) |
- |
|
|
|
| 7.1 & Table 2 (f) |
- |
|
|
|
| 7.1 & Table 3 (DI) |
- |
|
|
|
| 7.1 & Table 3 (P) |
- |
|
|
|
| 7.1 & Table 3 (g) |
- |
|
|
|
| 7.1 & Table 3 (h) |
- |
|
|
|
| 7.1 & Table 4 (D) |
- |
|
|
|
| 7.1 & Table 4 (a) |
- |
|
|
|
| 7.1 & Table 4 (b) |
- |
|
|
|
| 7.1 & Table 4 (s) |
- |
|
|
|
| 7.1 & Table 4 (r) |
- |
|
|
|
| 7.1 & Table 5 (D) |
- |
|
|
|
| 7.1 & Table 5 (C) |
- |
|
|
|
| 7.1 & Table 5 (Holes Number) |
- |
|
|
|
| 7.1 & Table 5 (Holes Diameter) |
- |
|
|
|
| 7.1 & Table 5 (Diameter of Bolts) |
- |
|
|
|
| 7.1 & Table 6 to 8 (DE) |
- |
|
|
|
| 7.1 & Table 6 to 8 (t) |
- |
|
|
|
| 7.1 & Table 6 to 8 (Mass of one meter barrel (Approx)) |
- |
|
|
|
| 7.1 & Table 6 to 8 (Socket mass (Approx)) |
- |
|
|
|
| 7.1 & Table 6 to 8 (Total mass for one working length in meter) |
- |
|
|
|
| 8.4 (Permissible deviation from a straight line) |
- |
|
|
|
| 9.1,Table 9 (DE) |
- |
|
|
|
| 9.1,Table 9 (e) |
- |
|
|
|
| 9.1,Table 9 (Flange, Mass of one meter (Approx)) |
- |
|
|
|
| 9.1,Table 9 (Mass of one flange (Approx)) |
- |
|
|
|
| 9.1,Table 9 (Working Length) |
- |
|
|
|
| 10.1 to 10.6 (Coating ) |
- |
|
|
|
| 3.1 , 6 of IS 210 ( The composition of cast iron shall be left to the
discretion of the manufacturer) |
- |
|
|
|
| 7.1 & Table 5 (Holes Number) |
- |
|
|
|
|
- |
- Excluding HST for size above 300 mm, Facility for chemical test is not available |
| 14966 |
BIS, Central Laboratory (CL)
| None
| IS 3829 : Part 1 (1999) |
Specification for steam sterilizers: Part 1 horizontal cylindrical and horizontal rectangular steam sterilizers, pressure type (For Hospital And Pharmaceutical Use) (Second Revision) |
- |
Please see remarks. View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl. 4 (Design) |
- |
|
|
|
| Cl. 5 - Table 1 & 2 (Shape & Size) |
- |
|
|
|
| Cl. 7 (Construction) |
- |
|
|
|
| Cl. 8 (Fittings) |
- |
|
|
|
| Cl. 9 (Hydrostatic test) |
- |
|
|
|
| Cl. 9 (Hydrostatic test) |
- |
|
|
|
| Cl. 9 (Hydrostatic test) |
- |
|
|
|
| Cl. 10 (Method of stem supply to Sterilizer) |
- |
|
|
|
| 6.1, 6.2 (Chamber) |
- |
|
|
|
| 6.1, 6.2 (Jacket) |
- |
|
|
|
| 6.1 and 6.2 (Other) |
- |
|
|
|
| Cl. 10.8 (Capacity) |
- |
|
|
|
| 4 (Design) |
- |
|
|
|
| 5 (Shape & Size) |
- |
|
|
|
| 6 (Materials) |
- |
|
|
|
| 7 (Construction) |
- |
|
|
|
| 8 (Fittings) |
- |
|
|
|
| 9 (Hydrostatic test) |
- |
|
|
|
| 10 (Methods of steam supply to sterilizer) |
- |
|
|
|
| 11 (Accessories) |
- |
|
|
|
| 12 (Marking) |
- |
|
|
|
|
- |
- - |
| 14967 |
BIS, Central Laboratory (CL)
| None
| IS 4368 (1967) |
Specification for alloy steel billets, blooms and slabs for forging for general engineering purposes |
- |
- View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl 5 (Freedom from Defects) |
- |
|
|
|
| Cl 8 (Diameter, Ovality & Weight) |
- |
|
|
|
| Cl 11 (Hardness & Tensile Test) |
- |
|
|
|
|
- |
- Steel designation as per Table 1 may be delcraed. Sample size having minimum dia > 3mm and thickness > 0.8 mm shall be provided.; |
| 14968 |
BIS, Southern Regional Laboratory (SRL)
| None
| IS 14246 (2013) |
Continuously pre-painted galvanized steel sheets and coils (First Revision) |
- |
4700 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl 6.2 (Press) |
- |
|
|
|
| Cl 6.3 (HWB) |
- |
|
|
|
| Cl 6.4 (Load Resistance) |
- |
|
|
|
| Cl 6.5 (Cross Hatch) |
- |
|
|
|
| Cl 9 (Length, Width, Thickness & Mass) |
- |
|
|
|
| Cl 10 (Camber, Deviation From Squareness (Out-of- Square) & Deviation From Flatness) |
- |
|
|
|
|
- |
- Excluding Only dimentions test available |
| 14969 |
BIS, Western Regional Laboratory (WRL)
| None
| IS 4947 (2006) |
Foam concentrate for producing mechanical foam for fire fighting - Specification (Fourth Revision) |
- |
Please see remarks. View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Clause 4.1 (A) (Carbon) |
- |
|
|
|
| Clause 4.1 (A) (Silicon) |
- |
|
|
|
| Clause 4.1 (A) (Sulphor ) |
- |
|
|
|
| Clause 4.1 (A) (Phosphorous) |
- |
|
|
|
| Clause 4.1 (A) (Manganese) |
- |
|
|
|
| Cl 3 (General Requirements) |
- |
|
|
|
| Cl 6 (Capacity and Contents) |
- |
|
|
|
| Cl 5 (Construction) |
- |
|
|
|
| Cl 7 (Performance Requirements ) |
- |
|
|
|
| Cl 7.3 (Leakage Test) |
- |
|
|
|
| Cl 8 (Finish) |
- |
|
|
|
|
- |
- Test facilities are not available for the following:
(1) Pitch and included angle |
| 14970 |
BIS, Central Laboratory (CL)
| None
| IS 14183 (1994) |
Pesticide - Cartap hydrochloride SP - Specification |
- |
Rs.3800.00 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 3.2 (Description) |
- |
|
|
|
| 3.3 Table 1 iii (pH or 10 percent ( mlm ) extract) |
- |
|
|
|
| 3.3 Table 1 ii (Matter insoluble in water ) |
- |
|
|
|
|
- |
- - |