| 15151 |
BIS, Southern Regional Laboratory (SRL)
| None
| IS 170 (2020) |
Acetone — Specification ( Fifth Revision ) |
- |
- View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl No 3.1 ( Description) |
- |
|
|
|
| Cl No 3.2 (Miscibility with Water) |
- |
|
|
|
| Cl 3.3 and 6.1 [ Table 1, Sl No. (vi) ] ref to 8 of IS 82 (Residue on evaporation) |
- |
|
|
|
| Cl 3.3 and 6.1 ANNEX C [ Table 1, Sl No. (vii) ] (Acidity (as CH3COOH),) |
- |
|
|
|
| Cl 3.3 and 6.1 ANNEX D [ Table 1, Sl No. (viii) ] (Alkalinity) |
- |
|
|
|
| Cl 3.3 and 6.1 ANNEX E [ Table 1, Sl No. (ix) ] (Permanganate test) |
- |
|
|
|
| Cl 3.3 and 6.1 ANNEX F [ Table 1, Sl No. (x) ] (Alcoholic impurities) |
- |
|
|
|
|
- |
- " 500 ml x 2
Excluding except purity of acetone, water content, colour, distillation range, benzene content, methanol content |
| 15152 |
BIS, Southern Regional Laboratory (SRL)
| None
| IS 253 (2014) |
Specification for common salt (Fourth Revision) |
- |
6690 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Clause -3 for common salt 3.1 ( 3.1.1 ) ( The material shall be crystalline solid, white or pale pink or light grey in colour.) |
- |
|
|
|
| Clause -3 for common salt 3.1 ( 3.1.2 ) Annex-2 (Moisture The material shall contain not more than 6.0 percent by mass of moisture, on as received basis, when tested according to the method given in A-2) |
- |
|
|
|
| Clause-3.2 for dairy salt (3.2.1) (The material shall be crystalline white solid and free from any visible impurities.) |
- |
|
|
|
| Clause-3.2 for dairy salt (3.2.3) Annex -2 (3.2.3 Moisture The material shall contain not more than 0.5 percent by mass of moisture, on as received basis, when tested according to the methods given in A-2.) |
- |
|
|
|
| Table 1 (i) Annex -4 (Water insoluble matter, common) |
- |
|
|
|
| Table 1 (i) Annex -4 (Water insoluble matter, Dairy) |
- |
|
|
|
| Table 1 (ii) Annex-5 (Chloride content (as NaCl)common) |
- |
|
|
|
| Table 1 (ii) Annex-5 (Chloride content (as NaCl), Dairy) |
- |
|
|
|
| Table 1 (iii) Annex-6 ( Matter soluble in water, other than sodium chloride, common) |
- |
|
|
|
| Table 1 (iii) Annex-6 ( Matter soluble in water, other than sodium chloride, Dairy) |
- |
|
|
|
| Table 1 (iv) (Calcium (as Ca), water soluble, percent by mass, common) |
- |
|
|
|
| Table 1 (iv) Annex-7 (Calcium (as Ca), water soluble, percent by mass, Dairy) |
- |
|
|
|
| Table 1 (v) (Magnesium (as Mg), water soluble, percent by mass, common ) |
- |
|
|
|
| Table 1 (v) Annex-7 (Magnesium (as Mg), water soluble, percent by mass, Dairy ) |
- |
|
|
|
| Table 1 (vi) (Sulphate as SO2 percent by mass, common) |
- |
|
|
|
| Table 1 (vi) Annex-8 (sulphate as SO2 percent by mass, Dairy) |
- |
|
|
|
| Table 1 (vii) Annex-9 (Alkalinity (as Na2CO3), common) |
- |
|
|
|
| Table 1 (vii) Annex-11 (Alkalinity (as Na2CO3), Dairy) |
- |
|
|
|
| Table 1 (viii) (Lead (as Pb), common) |
- |
|
|
|
| Table 1 (viii) (Lead (as Pb),Dairy ) |
- |
|
|
|
| Table 1 (ix) (Iron (as Fe), common) |
- |
|
|
|
| Table 1 (ix) (Iron (as Fe), Dairy) |
- |
|
|
|
| Table 1 (x) Annex-11 (x) Arsenic (as As), common) |
- |
|
|
|
| Table 1 (x) Annex-11 (x) Arsenic (as As),Dairy) |
- |
|
|
|
| Table 1 (xi) Annex-12 (Copper (as Cu), common) |
- |
|
|
|
| Table 1 (xi) Annex-12 (Copper (as Cu), Dairy ) |
- |
|
|
|
|
- |
- " 500 g |
| 15153 |
BIS, Southern Regional Laboratory (SRL)
| None
| IS 4148 (1989) |
Surgical rubber gloves - Specification (First Revision) |
- |
Rs. 3925/- View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4.5 (pH of Aqueous Extract ) |
- |
|
|
|
| 4.2 (Dimensions Fig 1 and Table 1) |
- |
|
|
|
| 4.2 (Dimensions Fig 1 and Table 1) |
- |
|
|
|
| 4.1.1 (Manufacture) |
- |
|
|
|
| 4.1.2 (Manufacture) |
- |
|
|
|
| 4.1.3 (Manufacture) |
- |
|
|
|
| 4.1.4 (Manufacture) |
- |
|
|
|
| 4.3 (Thickness) |
- |
|
|
|
| 4.4.1 (Physical Properties) |
- |
|
|
|
| 4.4.1 (Physical Properties) |
- |
|
|
|
| 4.4.2 (After accelerated aging at 70 + 1OC for 240 h ) |
- |
|
|
|
| 4.4.2 (After accelerated aging at 70 + 1OC for 240 h ) |
- |
|
|
|
| 4.4.2 (After accelerated aging at 70 + 1OC for 240 h ) |
- |
|
|
|
| 4.4.3 (After heat ageing in autoclave) |
- |
|
|
|
| 4.2 (Dimensions Fig 1 and Table 1) |
- |
|
|
|
| 4.2 (Dimensions Fig 1 and Table 1) |
- |
|
|
|
| 4.2 (Dimensions Fig 1 and Table 1) |
- |
|
|
|
| 4.2 (Dimensions Fig 1 and Table 1) |
- |
|
|
|
| 4.2 (Dimensions Fig 1 and Table 1) |
- |
|
|
|
| 4.4.4 (Tension Set) |
- |
|
|
|
|
- |
- " 20 Pairs |
| 15154 |
BIS, Southern Regional Laboratory (SRL)
| None
| IS 4581 (1978) |
Specification for phosphorus trichloride, pure and analytical reagent (First Revision) |
- |
- View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 3.1 (Description ) |
- |
|
|
|
| 3.2, Table 1 and A-2 of IS 4581 (Phosphprus Tricloride ( as PCl3 ) - For Analytical Reagent ) |
- |
|
|
|
| 3.2, Table 1 and A-2 of IS 4581 (Phosphprus Tricloride ( as PCl3 ) - For Pure grade) |
- |
|
|
|
| 3.2, Table 1 and A-5 of IS 4581 (Sulphate ( as SO4) - For Analytical Reagent) |
- |
|
|
|
| 3.2, Table 1 and A-7 of IS 4581 (Iron ( as Fe ) - For Analytical Reagent) |
- |
|
|
|
|
- |
- " 500 ml "
Excluding except boiling range, residue on evaporation for all grades; heavy metals for grade 1 |
| 15155 |
BIS, Southern Regional Laboratory (SRL)
| None
| IS 5295 (1985) |
Specification for ethylene glycol (First Revision) |
- |
Rs. 1500 Fibre Grade View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl No. 3.1 (Description) |
- |
|
|
|
| Cl No. 3.2 [ Table 1, Sl no.(i) ] Appendix A-2 FibreGrade only (Colour) |
- |
|
|
|
| Cl No. 3.2 [ Table 1, Sl no.(ii) ] Appendix A-2 FibreGrade only (Colour after boiling for 4 hour under total reflux) |
- |
|
|
|
| Cl No. 3.2 [ Table 1, Sl no.(vi) ] Appendix A-6 General Grade & Fibre Grade (Acidity ( as acetic acid)) |
- |
|
|
|
| Cl No. 3.2 [ Table 1, Sl no.(vii) ] Appendix A- 7 General Grade & Fibre Grade (Ash) |
- |
|
|
|
| Cl No. 3.2 [ Table 1, Sl no.(x) ] Appendix A-10 Fibre Grade only (Iron Content ) |
- |
|
|
|
| Cl No. 3.2 [ Table 1, Sl no.(xi) ] Appendix A-11 Fibre Grade only (Chlorides content ( as Cl )) |
- |
|
|
|
|
- |
- " 500 g x 2
Excluding except distillation range, moisture content, freezing point for General grade; except diethylene glycol content, relative density, colour, colour after boiling, uv transmitance, distillation range, moisture content for Fibre grade |
| 15156 |
BIS, Southern Regional Laboratory (SRL)
| None
| IS 6100 (1984) |
Specification for sodium tripolyphosphate, anhydrous, technical (First Revision) |
- |
- View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 2.1 (Description) |
- |
|
|
|
| 2.3, Table 1 and Appendix B-2 of IS 6100 (Moisture) |
- |
|
|
|
| 2.3, Table 1 and Appendix B-3 of IS 6100 (Matter insoluble in water) |
- |
|
|
|
| 2.3, Table 1 and Appendix B-4 of IS 6100 (Phosphorus ( as P2O5 )) |
- |
|
|
|
| 2.3, Table 1 and Appendix B-5 of IS 6100 (pH value) |
- |
|
|
|
|
- |
- " 500g "
Excluding except Iron, Copper, sieve analysis, fluoride, temperature rise |
| 15157 |
BIS, Southern Regional Laboratory (SRL)
| None
| IS 650 (1991) |
Standard sand for testing cement - Specification (Second Revision) |
- |
Rs 1500.00 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 5.1 (Chemical Req) |
- |
|
|
|
| Cl. 4.1 (shall be of quartz, light grey or whitish variety and shall be free from silt. The sand grains shall be angular, the shape of the grains approximating to the spherical form; elongated and flattened grains being present only in very small or negligible quantities) |
- |
|
|
|
| Cl. 4.2 (Sieve test and particle size distribution) |
- |
|
|
|
|
- |
- - |
| 15158 |
BIS, Southern Regional Laboratory (SRL)
| None
| IS 7466 (1994) |
Rubber gaskets for pressure cookers - Specifications (First Revison) |
- |
Rs.9480/- View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Clause 4.3 Table 1 (Zinc oxide) |
- |
|
|
|
| Clause 3.4 Table 1 (Heavy metal content) |
- |
|
|
|
| 3.2 (Workmanship and Finish ) |
- |
|
|
|
| 3.4-Table 1(ii) (Requirements of Rubber Used for Gaskets-Tensile strength,) |
- |
|
|
|
| 3.4-Table 1(iii) (Requirements of Rubber Used for Gaskets-Elongation at break) |
- |
|
|
|
| 3.4-Table 1(iv-b) (Requirements of Rubber Used for Gaskets-Tensile strength(After ageing 3 days in Aie-oven Change From Original Value)) |
- |
|
|
|
| 3.4-Table 1(iv-c) (Requirements of Rubber Used for Gaskets-Elongation at break(After ageing 3 days in Aie-oven Change From Original Value)) |
- |
|
|
|
| 3.4-Table 1(v-b) (Requirements of Rubber Used for Gaskets-Tensile strength(After ageing in an autoclave Change From Original Value)) |
- |
|
|
|
| 3.4-Table 1(v-c) (Requirements of Rubber Used for Gaskets-Elongation at break(After ageing in an autoclave Change From Original Value)) |
- |
|
|
|
| 3.4-Table 1(vi) (Compression set) |
- |
|
|
|
| 3.4-Table 1(i) (Requirements of Rubber Used for Gaskets-Hardness IRHD) |
- |
|
|
|
| 3.4-Table 1(iv-a) (Requirements of Rubber Used for Gaskets-Hardness IRHD(After ageing 3 days in Aie-oven Change From Original Value)) |
- |
|
|
|
| 3.4-Table 1(v-a) (Requirements of Rubber Used for Gaskets-Hardness IRHD(After ageing in an autoclave Change From Original Value)) |
- |
|
|
|
| 3.4-Table 1(vi) (Compression set) |
- |
|
|
|
|
- |
- " 3 Nos Gaskets, 12 Big button, 8 slabs
Excluding For Performance test Pressure Cooker of corresponding Gasket is required to be provided |
| 15159 |
BIS, Southern Regional Laboratory (SRL)
| None
| IS 797 (1982) |
Specification for common salt for chemical industries (Third Revision) |
- |
- View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl.3.1 (Description) |
- |
|
|
|
| Cl.3.2.1 (Moisture Content For Grade 1 material (Annex A2)) |
- |
|
|
|
| Cl.3.2.2 (Moisture Content For Grade 2 material (Annex A2)) |
- |
|
|
|
| Table 1 Cl.3.3 (Sodium Chloride (as NaCl) For Grade 1 material (Annex A3)) |
- |
|
|
|
| Table 1 Cl.3.3 (Sodium Chloride (as NaCl) For Grade 2 material (Annex A3)) |
- |
|
|
|
| Table 1 Cl.3.3 (Material insoluble in water For Grade 1 material (Annex A4)) |
- |
|
|
|
| Table 1 Cl.3.3 (Material insoluble in water For Grade 2 material (Annex A4)) |
- |
|
|
|
| Table 1 Cl.3.3 (Calcium salts (as Ca) For Grade 1 material (Annex A5)) |
- |
|
|
|
| Table 1 Cl.3.3 (Calcium salts (as Ca) For Grade 2 material (Annex A5)) |
- |
|
|
|
| Table 1 Cl.3.3 (Magnasium salts (as Mg) For Grade 1 material (Annex A5)) |
- |
|
|
|
| Table 1 Cl.3.3 (Magnasium salts (as Mg) For Grade 2 material (Annex A5)) |
- |
|
|
|
| Table 1 Cl.3.3 (Sulphates (as SO4) For Grade 1 material (Annex A6)) |
- |
|
|
|
| Table 1 Cl.3.3 (Sulphates (as SO4) For Grade 2 material (Annex A6)) |
- |
|
|
|
| Table 1 Cl.3.3 (Iron compound (as Fe) For Grade 1 material (Annex A7)) |
- |
|
|
|
| Table 1 Cl.3.3 (Iron compound (as Fe) For Grade 2 material (Annex A7)) |
- |
|
|
|
|
- |
- " 2 x 500 g "
Excluding Excl TF for Table 1 & 3.3.1 |
| 15160 |
BIS, Southern Regional Laboratory (SRL)
| None
| IS 798 (2020) |
Orthophosphoric Acid — Specification ( Third Revision ) |
- |
Rs.14822/- View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4.1 (Description) |
- |
|
|
|
| 5.2.2 Table 1 (ii) (Orthophosphoric acid (H3 PO4 )) |
- |
|
|
|
| 5.2.2 Table 1 (iii) (Iron (as Fe), ) |
- |
|
|
|
| 5.2.2 Table 1 (iv) (Chlorides (as Cl), ) |
- |
|
|
|
| 5.2.2 Table 1 (v) (Sulphates (as SO4 ), ) |
- |
|
|
|
| 5.2.2 Table 1 (vi) (Arsenic (as As2 O3 ), ) |
- |
|
|
|
| 5.2.2 Table 1 (viii) (Nitrates (as NO3 ),) |
- |
|
|
|
| 5.2.2 Table 1 (ix) (Lead (as Pb), parts per million, Max) |
- |
|
|
|
| 5.2.2 Table 1 (x) (Silica (as SiO2 ), ) |
- |
|
|
|
| 5.2.2 Table 1 (xii) (Oxygen absorbed (as O),) |
- |
|
|
|
| 5.2.2 Table 1 (xiv) (Manganese (as Mn), ) |
- |
|
|
|
| 5.2.2 Table 1 (xvi) (Mercury (as Hg), ) |
- |
|
|
|
| 5.2.2 Table 1 (xvii) (Aluminium (as Al), ) |
- |
|
|
|
|
- |
- " 500 g "
Excluding except Calcium, Magnesium, relative density, Volatile acid for AR Grade ; Molybdenum, relative density, Antimony for For Technical grade |
| 15161 |
BIS, Southern Regional Laboratory (SRL)
| None
| IS 8041 (1990) |
Rapid hardening portland cement - Specific4tion (Second Revision) |
- |
Please see remarks View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 5.1 - Table - 1 i (Ratio of percentage of lime to percentages of silica, alumina and iron oxide - Cl 4 of IS 4032:1985) |
- |
|
|
|
| 5.1 - Table - 1 ii (Ratio of percentage of alumina to that of iron oxide - Cl 4 of IS 4032:1985) |
- |
|
|
|
| 5.1 - Table - 1 iii (Insoluble residue - Cl 4.10 of IS 4032:1985) |
- |
|
|
|
| 5.1 - Table - 1 iv (Magnesia - Cl 4.8 of IS 4032:1985) |
- |
|
|
|
| 5.1 - Table - 1 v (Total Sulphur Content calculated as Sulphuric Anhydride (SO3) - Cl 4.9 of IS 4032:1985) |
- |
|
|
|
| 5.1 - Table - 1 vi (Total loss on ignition - Cl 4.2 of IS 4032:1985) |
- |
|
|
|
| 6.1 (Fineness 4031 Part 2) |
- |
|
|
|
| 6.2.1 (Expansion by Le Chatelier- 4031 Part 3) |
- |
|
|
|
| 6.2.1 (Expansion by Autoclave- 4031 Part 3) |
- |
|
|
|
| 6.3 a) (Setting Time Initial- 4031 Part 5) |
- |
|
|
|
| 6.3 b) (Setting Time Final- 4031 Part 5) |
- |
|
|
|
| 6.4 a) (Compressive Strength At 24 hrs ± 30 minutes - IS 4031 Part 6) |
- |
|
|
|
| 6.4 b) (Compressive Strength At 72 hrs ± 1 hr - IS 4031 Part 6) |
- |
|
|
|
|
- |
- " 8 kg + 500g "
Excluding Except Transverse test (Optional) |
| 15162 |
BIS, Southern Regional Laboratory (SRL)
| None
| IS 8043 (1991) |
Specification for hydrophobic Portland cement |
- |
- View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 5.1 (ref. 6 - Table - 1 i of IS 269:2015) (Ratio of percentage of lime to percentages of silica, alumina and iron oxide - Cl 4 of IS 4032:1985) |
- |
|
|
|
| 5.1 (ref. 6 - Table - 1 ii of IS 269:2015) (Ratio of percentage of alumina to that of iron oxide - Cl 4 of IS 4032:1985) |
- |
|
|
|
| 5.1 (ref. 6 - Table - 1 iii of IS 269:2015) (Insoluble residue - Cl 4.10 of IS 4032:1985) |
- |
|
|
|
| 5.1 (ref. 6 - Table - 1 iv of IS 269:2015) (Magnesia - Cl 4.8 of IS 4032:1985) |
- |
|
|
|
| 5.1 (ref. 6 - Table - 1 v of IS 269:2015) (Total Sulphur Content calculated as Sulphuric Anhydride (SO3) - Cl 4.9 of IS 4032:1985) |
- |
|
|
|
| 5.1 (ref. 6 - Table - 1 vi of IS 269:2015) (Loss on ignition - Cl 4.2 of IS 4032:1985) |
- |
|
|
|
| 5.1 (ref. 6 - Table - 1 vii of IS 269:2015) (Chloride content - Cl 4.13 of IS 4032:1985) |
- |
|
|
|
| 5.1 (ref. 6 - Table - 1 viii of IS 269:2015) ( Alkali content as (Na2O + 0.658 K2O) - Cl 4.11 of IS 4032:1985) |
- |
|
|
|
|
- |
- " mech - 8 kg; chem - 500 g
Excluding Mech-Except transverse strength(optional), Hydrophobicity test; Chem-except Alkali content |
| 15163 |
BIS, Southern Regional Laboratory (SRL)
| None
| IS 8229 (1986) |
Specification for oil - Well cement (First Revision) |
ordinary, moderate & high sulphate resistant type |
5400 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4.1 - Table - 1 i (Magnesium Oxide (MgO) - Cl 4.8 of IS 4032:1985) |
- |
|
|
|
| 4.1 - Table - 1 ii (Sulphur Trioxide(SO3) - Cl 4.9 of IS 4032:1985) |
- |
|
|
|
| 4.1 - Table - 1 iii (Loss on ignition - Cl 4.2 of IS 4032:1985) |
- |
|
|
|
| 4.1 - Table - 1 iv (Insoluble residue - Cl 4.10 of IS 4032:1985) |
- |
|
|
|
| 4.1 - Table - 1 v (Tricalcium aluminate (3CaO.Al2O3) - Cl 4 of IS 4032:1985) |
- |
|
|
|
| 4.1 - Table - 1 x (Tricalcium Silicate (3CaO.SiO2) - Cl 4 of IS 4032:1985) |
- |
|
|
|
| 4.1 - Table - 1 xix (Tetracalcium aluminoferrite (4CaO.Al2O3.Fe2O3) plus twice the tricalcium aluminate (3CaO.Al2O3) - Cl 4 of IS 4032:1985) |
- |
|
|
|
| 4.1 - Table - 1 i (Magnesium Oxide (MgO) - Cl 4.8 of IS 4032:1985) |
- |
|
|
|
| 5.1 and Table 2 ii (Fineness
IS : 4031:1988) |
- |
|
|
|
| 5.1 and Table 2 iii (Soundness, Autoclave expansion
IS 4031:1988) |
- |
|
|
|
|
- |
- " mech - 8 kg; chem - 500 g
Excluding Mech- except water, free water content of slurry, preparation of slurry, thickening time, compressive strength; Chem- except alkali content for Class- G & H |
| 15164 |
BIS, Southern Regional Laboratory (SRL)
| None
| IS 9825 (2003) |
Chlorine tablets - Specification (Second Revision) |
- |
Rs.4330/ View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl.4.2 (Description) |
- |
|
|
|
| Cl.4.3 (Size (Mass of tablet)) |
- |
|
|
|
| Cl.4.3 (Available Chlorine (Annex A)) |
- |
|
|
|
| Cl.4.4 (Moisture (Annex B)) |
- |
|
|
|
| Cl.4.4 (Shelf Life (Annex A)) |
- |
|
|
|
|
- |
- 2x500g |
| 15165 |
BIS, Northern Regional Laboratory (NRL)
| None
| IS 13334 : Part 1 (2014) |
Skimmed milk powder - Specification: Part 1 standard grade (Second Revision) |
- |
10430/- View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 5.6 (Moisture) |
- |
|
|
|
| 5.6 (Total ash (on dry basis)) |
- |
|
|
|
| 5.6 (Insolubility index) |
- |
|
|
|
| 5.6 (Titratable acidity (lactic acid)) |
- |
|
|
|
| 5.6 (Milk fat) |
- |
|
|
|
| 4 (Description) |
- |
|
|
|
| 5.6 (Listeria monocytogenes) |
- |
|
|
|
| 5.6 (Spore count, Anaerobic (Sulfite reducing Clostridia)) |
- |
|
|
|
| 5.6 (Spore count, Aerobic (Bacillus cereus)) |
- |
|
|
|
| 5.6 (Salmonella) |
- |
|
|
|
| 5.6 (Coagulase positive Staphylococcus aureus) |
- |
|
|
|
| 5.6 (Escherichia coli) |
- |
|
|
|
| 5.6 (Coliform count ) |
- |
|
|
|
| 5.6 (Bacterial count) |
- |
|
|
|
| 5.6 (Scorched particles) |
- |
|
|
|
| 5.6 (Milk protein in milk solids not fat) |
- |
|
|
|
| Cl 5.4 (The flavour of the product or of the reconstituted
milk shall be pleasant and clean (see IS 10030).) |
- |
|
|
|
|
- |
- Testing Facility is complete |
| 15166 |
BIS, Southern Regional Laboratory (SRL)
| None
| IS 14255 (1995) |
Aertal bunched cables - For working voltages up to and including 1100 Volts - Specification |
- |
Please see remarks View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4.1 (Phase/Street Lighting conductor) |
- |
|
|
|
| 4.2 (Messenger (Neutral Conductor or Otherwise)) |
- |
|
|
|
| 5.1 (Insulation) |
- |
|
|
|
| 6.1 (Flexibility class) |
- |
|
|
|
| 6.2 (Compactness) |
- |
|
|
|
| 6.2 (No of strands) |
- |
|
|
|
| 6.2 (Surface) |
- |
|
|
|
| 6.3 (Protective barrier) |
- |
|
|
|
| 6.4 (size of street lighting conductor) |
- |
|
|
|
| 6.5 (Size of messenger conductor ) |
- |
|
|
|
| 6.6 (Joints in messenger conductor ) |
- |
|
|
|
| 6.6 (Direction of outer layer) |
- |
|
|
|
| 7.1 (Insulation) |
- |
|
|
|
| 7.2 ( Thickness of insulation) |
- |
|
|
|
| 7.3 (Tolerance on thickness of insulation ) |
- |
|
|
|
| 7.4 (Aplication of the insulation ) |
- |
|
|
|
| 7.5 (Colour of the insulation ) |
- |
|
|
|
| 8.1 (Core identification) |
- |
|
|
|
| 8.2 (Core identification) |
- |
|
|
|
| 8.3 (Identification by other means) |
- |
|
|
|
| 9.1 (Assembly (Laying up)) |
- |
|
|
|
| 9.2 (Assembly (Laying up)) |
- |
|
|
|
| 9.3 (Direction of lay) |
- |
|
|
|
| 10.1 a) i) (Tests on phase/street light conductor: tensile test - Test method IS10810:Part 2) |
- |
|
|
|
| 10.1 a) ii) (Wrapping test - 10810: Part 3) |
- |
|
|
|
| 10.1 a) iii) (Resistance test - IS10810: Part 5) |
- |
|
|
|
| 10.1 b) i) (Test on messenger conductor: Breaking load - IS 10810: Part 2) |
- |
|
|
|
| 10.1 b) ii) (Test on messenger conductor: Elongation test - Cl 11.3) |
- |
|
|
|
| 10.1 b) iii) (Test on messenger conductor: Resistance test - IS 10810: Part 5) |
- |
|
|
|
| 10.1 c) i) (Physical tests for XLPE Insulation:
Tensile strength - IS 10810: Part 7) |
- |
|
|
|
| 10.1 c) i) (Physical tests for XLPE Insulation:
elongation at break - IS 10810: part 7) |
- |
|
|
|
| 10.1 c) ii) (Ageing in air oven : Tensile strength variation - IS 10810:Part 11) |
- |
|
|
|
| 10.1 c) ii) (Ageing in air oven : Elongation variation- IS 10810: Part 11) |
- |
|
|
|
| 10.1 c) iii) (Hot set test: Elongation under load - IS 10810: Part 30) |
- |
|
|
|
| 10.1 c) iii) (Hot set test: Permanent elongation (set) after cooling - IS 10810: Part 30) |
- |
|
|
|
| 10.1 c) iv) (Shrinkage test : Shrinkage - 10810:Part 12) |
- |
|
|
|
| 10.1 c) iv) (Shrinkage test : Crack Observed - 10810:Part 12) |
- |
|
|
|
| 10.1 c) v) (Water ahsorption (Gravimetric) - IS 10810: Part 33 ) |
- |
|
|
|
| 10.1 d) i) (Physical test for PE insulation:
Tensile strength - IS 10810: Part 7 ) |
- |
|
|
|
| 10.1 d) i) (Physical test for PE insulation: elongation at break - IS 10810: Part 7) |
- |
|
|
|
| 10.1 f) (Insulation resistance (Volume resistivity) test a) volume resistivity at 27°C - IS 10810: Part 43) |
- |
|
|
|
| 10.1 f) (Insulation resistance (Volume resistivity) test b) volume resistivity at 70°C - IS 10810: Part 43) |
- |
|
|
|
| 10.1 g) (High voltage test - IS10810:Part 45) |
- |
|
|
|
|
- |
- " 15m
Excluding 1.)Complete for XLPE Insulation ; 2.)Except Carbon black test , Melt flow index , Vicat softening point , Environmental stress cracking test for PE insulation, Except C1 & C2 Category |
| 15167 |
BIS, Southern Regional Laboratory (SRL)
| None
| IS 9537 : Part 3 (1983) |
Specification for conduits for electrical installations: Part 3 rigid plain conduits of insulating meterials |
- |
Please check remarks View breakup
a) Total testing charges including type test for sizes upto and including 25 mm- Rs. 3300.00 b)Total testing charges including type test for sizes above 25 mm - Rs. 2850.00
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 6.1 (Marking) |
- |
|
|
|
| 6.2 (Durability of Marking as per 6.4 of IS: 9537 (Part 1)-1980) |
- |
|
|
|
| 6.3 (Standard Mark on Conduit) |
- |
|
|
|
| 7.1.1 (Maximum and minimum outside diameter of socket) |
- |
|
|
|
| 7.1.1 Table-2 (Length of Socket end) |
- |
|
|
|
| 7.1.2 (Maximum and minimum outside diameter of conduit) |
- |
|
|
|
| 7.2 (Minimum inside diameter of conduit) |
- |
|
|
|
| 7.3 (Length of conduit) |
- |
|
|
|
| 7.4 (Unifomity of The wall Thickness) |
- |
|
|
|
| 8.1 (Construction as per clause 8 of IS: 9537 (Part 1)-1980) |
- |
|
|
|
| 9.2 (Bending Test i) At Room Temp ii) At Low Temp (-5 ±2°C)) |
- |
|
|
|
| 9.3 (Compression Test as per caluse 9.3 of IS: 9537 (Part 1)-1980) |
- |
|
|
|
| 9.4 (Impact Test as per clause 9.4 of IS: 9537 (Part 1)-1980) |
- |
|
|
|
| 9.5 (Collapse Test as per clause 9.5 of IS: 9537 (Part 1)-1980) |
- |
|
|
|
| 9.2 (Bending Test i) At Room Temp ii) At Low Temp (-5 ±2°C)) |
- |
|
|
|
| 10 (Resistance to Heat -Ball presure test) |
- |
|
|
|
| 11 (Resistance to burning as per clause 11 of IS: 9537 (Part 1)-1980) |
- |
|
|
|
| 12 (Electrical Characteristics-Test for electric strength as per clause 12.1.1 of IS: 9537 (Part 1)-1980) |
- |
|
|
|
| 12 (Electrical Characteristics-Insulation resistance test as per clause 12.1.2 of IS: 9537 (Part 1)-1980) |
- |
|
|
|
|
- |
- 6x3m |
| 15168 |
BIS, Southern Regional Laboratory (SRL)
| None
| IS 12045 (1987) |
Specification for alloys used in electrical resistance metallic heating elements |
- |
- View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 3.1 (Tensile Strength-IS 1608 (P- 1)) |
- |
|
|
|
| 3.1 (Hardness- IS 1586 (P-1)) |
- |
|
|
|
| 5.1,5.2 (Physical Condition- IS 12045) |
- |
|
|
|
|
- |
- " mech - 2 x 500 mm
Excluding except Chemical tests |
| 15169 |
BIS, Northern Regional Laboratory (NRL)
| None
| IS 8783 : Part 4 : Sec 1 (1995) |
Winding wires for submersible motors - Specification: Part 4 specification for indmdual wires: Sec 1 HR PVC insulated wires (First Revision) |
- |
9300/- View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl.5.1.1 (Dimensions) |
- |
|
|
|
| Cl. 6 (Annealing Test) |
- |
|
|
|
| Cl 6 (Resistance Test) |
- |
|
|
|
| Cl 4.1.2 (Visual examination) |
- |
|
|
|
| Cl. 4 Table 1of IS: 8783 (part 2) (Volume resistivity) |
- |
|
|
|
| Cl. 4 Table 1of IS: 8783 (part 2) (Volume resistivity) |
- |
|
|
|
| Cl. 4 Table 1of IS: 8783 (part 2) (Tensile strength ) |
- |
|
|
|
| Cl. 4 Table 1of IS: 8783 (part 2) (Elongation) |
- |
|
|
|
| Cl. 4 Table 1of IS: 8783 (part 2) (Tensile Strength) |
- |
|
|
|
| Cl. 4 Table 1of IS: 8783 (part 2) (Tensile strength ) |
- |
|
|
|
| Cl. 4 Table 1of IS: 8783 (part 2) (Elongation at Break ) |
- |
|
|
|
| Cl. 4 Table 1of IS: 8783 (part 2) (Shrinkage test ) |
- |
|
|
|
| Cl. 4 Table 1of IS: 8783 (part 2) (Shrinkage test ) |
- |
|
|
|
| Cl. 4 Table 1of IS: 8783 (part 2) (Water absorption (Gravimetric) ) |
- |
|
|
|
| Cl. 4 Table 1of IS: 8783 (part 2) (Hot deformation Test ) |
- |
|
|
|
| Cl. 4 Table 1of IS: 8783 (part 2) (Heat shock Test ) |
- |
|
|
|
| Cl.4.1 (Insulation ) |
- |
|
|
|
| Cl.4.2 (Application) |
- |
|
|
|
| Cl.4.3 (Colour) |
- |
|
|
|
| Cl.4.4 (Overall Diameter) |
- |
|
|
|
| Cl.4.5 (Finish) |
- |
|
|
|
| Cl.4.6 (High Voltage Test Water Immersion ) |
- |
|
|
|
|
- |
- Test facility is complete |
| 15170 |
BIS, Eastern Regional Laboratory (ERL)
| None
| IS 12367 (1988) |
Specification for cold - Rolled carbon steel strips/coils for manufacture of welded tubes |
All grades/varieties |
- View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 1.3 (Hardness) |
- |
|
|
|
| 5 (Tensile Test-1608:Part 1) |
- |
|
|
|
| 5.2.1, Table 3 (i) 0.2% Proof stress, Mpa) |
- |
|
|
|
| 2 (Reverse bend test) |
- |
|
|
|
| 5.2.1, Table 3 (iii)Elongation, %) |
- |
|
|
|
| 7 (Cupping test) |
- |
|
|
|
| 10 (Surface Finish(as per declaration)) |
- |
|
|
|
| 8 (Strain-ageing Embrittlement Test) |
- |
|
|
|
| 12 (Dimensions ) |
- |
|
|
|
| 11 (Freedom from Defects) |
- |
|
|
|
| 4.1 & 4.2 (Carbon- Relevant parts of IS 228 or any other established instrumental /Chemical method) |
- |
|
|
|
| 4.1 & 4.2 (Silicon- Relevant parts of IS 228 or any other established instrumental /Chemical method) |
- |
|
|
|
| 4.1 & 4.2 (Manganese- Relevant parts of IS 228 or any other established instrumental /Chemical method) |
- |
|
|
|
| 4.1 & 4.2 (Phosphorus- Relevant parts of IS 228 or any other established instrumental /Chemical method) |
- |
|
|
|
| 4.1 & 4.2 (Sulphur- Relevant parts of IS 228 or any other established instrumental /Chemical method) |
- |
|
|
|
| 4.1 & 4.2 (Titanium- Relevant parts of IS 228 or any other established instrumental /Chemical method) |
- |
|
|
|
| 4.1 & 4.2 (Nitrogen- Relevant parts of IS 228 or any other established instrumental /Chemical method) |
- |
|
|
|
| 4.1 & 4.2 (Aluminium- Relevant parts of IS 228 or any other established instrumental /Chemical method) |
- |
|
|
|
| 4.1 & 4.2 (Boron- Relevant parts of IS 228 or any other established instrumental /Chemical method) |
- |
|
|
|
| 4.1 & 4.2 (Vanadium- Relevant parts of IS 228 or any other established instrumental /Chemical method) |
- |
|
|
|
| 4.1 & 4.2 (Niobium- Relevant parts of IS 228 or any other established instrumental /Chemical method) |
- |
|
|
|
|
- |
- Grade to be declared.
Chem- Facility not available for Al, V, Nb, Ti, B & Mo. Type of killing and grade to be declared |
| 15171 |
BIS, Eastern Regional Laboratory (ERL)
| None
| IS 1239 : Part 2 (2011) |
Steel tubes, tubulars and other steel fittings - Specification: Part 2 steel pipe fittings (Fifth Revision) |
All types/sizes (pl see remarks) |
3400 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 7.1 (Chemical Composition - Sulphur - Laddle Analysis IS 228) |
- |
|
|
|
| 7.1 (Chemical Composition - Phosphorus - Laddle Analysis IS 228) |
- |
|
|
|
| 8.6 -Table 6 (Sockets) |
- |
|
|
|
| 14 (WORKMANSHIP) |
- |
|
|
|
| "Clauses 6.3.1 and 8.6 TABLE 6" ("Avarage Outside Diameter.(04)
") |
- |
|
|
|
| "Clauses 6.3.1 and 8.6 TABLE 6" ("Avarage Length (04)
") |
- |
|
|
|
|
- |
- Mech- Facility not available for Cl 11.1 (Hydrostatic or pneumatic), Taper screw plug test (Cl 11.2.2). Method of manufacture, type and size designation to be declared. |
| 15172 |
BIS, Southern Regional Laboratory (SRL)
| None
| IS 398 : Part 5 (1992) |
Aluminium conductor for overhead transmission purposes - Specification: Part 5 aluminium conductors - Galvanized steel - Reinforced for extra high voltage (400 KV And Above) (First Revision) |
- |
11400 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 7 (elec) (Freedom from
defects) |
- |
|
|
|
| 13.2 (mech) (Visual Examination) |
- |
|
|
|
| 13.3 Table-1 (mech) (Diameter-Aluminium wires) |
- |
|
|
|
| 13.3 Table-2 (mech) (Diameter-Galvanized Steel wires) |
- |
|
|
|
| 13.5.2 Table 1 (mech) (Breaking Load of Aluminium Wires Before Stranding) |
- |
|
|
|
| 13.5.2 Table 2 (mech) (Breaking Load of Steel Wires Before Stranding) |
- |
|
|
|
| 13.5.2 Table 1 (mech) (Breaking Load of Aluminium Wires After Stranding) |
- |
|
|
|
| 13.5.2 Table 2 (mech) (Breaking Load of Steel Wires After Stranding) |
- |
|
|
|
| 13.6.1 (mech) (Ductility by Torsion Test before stranding) |
- |
|
|
|
| 13.6.1 (mech) (Ductility by Torsion Test after stranding) |
- |
|
|
|
| 13.6.2 (mech) (Ductility by Elongation Test before stranding) |
- |
|
|
|
| 13.6.2 (mech) (Ductility by Elongation Test after stranding) |
- |
|
|
|
| 13.7.1 (mech) (Wrapping Test Aluminium Wires Before Stranding) |
- |
|
|
|
| 13.7.1 (mech) (Wrapping Test Aluminium Wires After Stranding) |
- |
|
|
|
| 13.7.2 (mech) (Wrapping Test Galvanized Steel Wires Before Stranding) |
- |
|
|
|
| 13.7.2 (mech) (Wrapping Test Galvanized Steel Wires After Stranding) |
- |
|
|
|
| 13.8 (elec) (Resistance test-Aluminium wire before Stranding) |
- |
|
|
|
| 14.8 (elec) (Resistance test-Aluminium wire after stranding) |
- |
|
|
|
| 13.9.2 (chem) (Mass of Zinc coating) |
- |
|
|
|
| 13.9.2 (chem) (Uniformity of Zinc coating) |
- |
|
|
|
| 13.4 Table-4 (mech) (Lay Ratio- Aluminium Wire Outermost Layer) |
- |
|
|
|
| 13.4 Table-4 (mech) (Lay Ratio- Aluminium Wire Layer Immediately Beneath Outermost Layer) |
- |
|
|
|
| 13.4 Table-4 (mech) (Lay Ratio- Aluminium Wire Innermost Layer of Conductors eith 3 Aluminium Wire Layers) |
- |
|
|
|
| 13.4 Table-4 (mech) (Lay Ratio- Steel Core (6 Wire Layer)) |
- |
|
|
|
|
- |
- " 5 m
Excluding Except surface, carona & Radio Interference Test |
| 15173 |
BIS, Southern Regional Laboratory (SRL)
| None
| IS 11952 (1986) |
Specification for steels for piston pins (Gudgeon Pins) |
- |
- View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 5.2, Table3 (i) Tensile Strength) |
- |
|
|
|
| 5.2, Table3 (ii) Hardness) |
- |
|
|
|
| 11 (TOLERANCES) |
- |
|
|
|
|
- |
- " mech - 2 x 500 mm
Excluding except inclusions test, magnetic particle test, Grain size, hardenability, surface defects and Chemical tests |
| 15174 |
BIS, Southern Regional Laboratory (SRL)
| None
| IS 1785 : Part 2 (1983) |
Specification for plain hard drawn steel wire for prestressed concrete: Part 2 as - Drawn wire (First Revision) |
- |
Rs 3000/- View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl 5.1 (Diameter) |
- |
|
|
|
| Cl 6.1 (Tensile Test On UTM) |
- |
|
|
|
| Cl 5.1.2 (Weight) |
- |
|
|
|
|
- |
- " 2mtl.
Excluding Except proof load, ductility, stress relaxation & reverse bend test |
| 15175 |
BIS, Central Laboratory (CL)
| None
| IS 1079 (2017) |
Hot rolled carbon steel sheet, plate and strip - Specification (Seventh Revision) |
- |
- View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl 8 (UTM) |
- |
|
|
|
| Cl 9 (Press) |
- |
|
|
|
| Cl 10 (Die Press) |
- |
|
|
|
| Cl 12 (Workmanship) |
- |
|
|
|
| Cl 13 (Length, Width & Thickness) |
- |
|
|
|
| 6.1 (Carbon %) |
- |
|
|
|
| 6.1 (Manganese %) |
- |
|
|
|
| 6.1 (Phosphorus %) |
- |
|
|
|
| 6.1 (Sulphur %) |
- |
|
|
|
| 6.1 ( Copper %) |
- |
|
|
|
| 6.1 ( Aluminium %) |
- |
|
|
|
| 6.1 ( Nitrogen%) |
- |
|
|
|
| 6.1 ( Nb) |
- |
|
|
|
| 6.1 (V) |
- |
|
|
|
| 6.1 ( Ti) |
- |
|
|
|
| 6.1 (Cr) |
- |
|
|
|
| 6.1 (Mo) |
- |
|
|
|
| 6.1 (Ni) |
- |
|
|
|
| 6.1 (Silicon %) |
- |
|
|
|
|
- |
- Grade/Designation, Quality type of killing and declaration regarding micro alloying elements addition may please be declared. Sample size- 5 pcs of 5 cm x 5 cm having dia> 3mm and thickness >0.8 mm; |
| 15176 |
BIS, Southern Regional Laboratory (SRL)
| None
| IS 1159 (1981) |
Specification for baking powder (First Revision) |
- |
Rs.2100/- View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Table 1 (i), Annax A (Available carbon dioxide) |
- |
|
|
|
| Table 1 (ii), CL 12 of
IS : 6287 • 1971 (Arsenic (as As)) |
- |
|
|
|
| Table 1 (iii), CI 13
IS : 6287 • 1971 (Heavy Metals (As Pb)) |
- |
|
|
|
|
- |
- " 500 g |
| 15177 |
BIS, Central Laboratory (CL)
| None
| IS 3854 (1997) |
Switches for domestic and similar purposes - Specification (Second Revision) |
- |
Please see remarks. View breakup
6A Screw type terminals-Rs.4900/-, 6A Screwless type terminals-Rs.5850/-,10A Screw type terminals-Rs.5050/-, 10A Screwless type terminals-Rs.6400/-, 16A Screw type terminals-Rs.5850/-,16A Screwless type terminals-Rs.7900/-, 20A-Rs.5250/-, 25A-Rs.5900/-, 32A-Rs.6250/-, 40A-Rs.6550/-, 63A-Rs.6200/-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 6 (Rating) |
- |
|
|
|
| 7 (Classification) |
- |
|
|
|
| 7 (Classification) |
- |
|
|
|
| 7 (Classification) |
- |
|
|
|
| 7 (Classification) |
- |
|
|
|
| 7 (Classification) |
- |
|
|
|
| 7 (Classification) |
- |
|
|
|
| 7 (Classification) |
- |
|
|
|
| 8 (Marking) |
- |
|
|
|
| 8 (Marking) |
- |
|
|
|
| 8 (Marking) |
- |
|
|
|
| 8 (Marking) |
- |
|
|
|
| 8 (Marking) |
- |
|
|
|
| 8 (Marking) |
- |
|
|
|
| 8 (Marking) |
- |
|
|
|
| 8.9 (Marking) |
- |
|
|
|
| 6 (Rating) |
- |
|
|
|
| 10 (Protection against Electric Shock) |
- |
|
|
|
| 11.1 (Provision for earthing) |
- |
|
|
|
| 12 (Terminals) |
- |
|
|
|
| 12.2.1 (Terminals) |
- |
|
|
|
| 12.2.2 (Connection of conductor) |
- |
|
|
|
| 12.2.3 (Mechanical strength of terminals) |
- |
|
|
|
| 12.2.4 (Resistance to corrosion) |
- |
|
|
|
| 12.2.5 (Undue damage to conductor) |
- |
|
|
|
| 12.2.7 (Insertion of conductor) |
- |
|
|
|
| 12.2.9 (Locking against accidental loosening) |
- |
|
|
|
| 12.2.11 (Distance between screw and conductor) |
- |
|
|
|
| 12.3.2 (Screwless terminals) |
- |
|
|
|
| 12.3.3 (Connectin of conductor) |
- |
|
|
|
| 12.3.4 (Material of terminals) |
- |
|
|
|
| 12.3.5 (Clamping) |
- |
|
|
|
| 12.3.7 (v) Interconnection of conductors [Cl. 12.3.7]) |
- |
|
|
|
| 12.3.11 (vi) Electrical & Thermal Stresses [Cl 12.3.11]) |
- |
|
|
|
| 12.3.12 (vii) Deflection Stresses [Cl. 12.3.12]) |
- |
|
|
|
| 13.1 (a) Insulating lining, barriers and the like [Cl 13.1]) |
- |
|
|
|
| 13.2 (b) Construction of switch [Cl 13.2]) |
- |
|
|
|
| 13.2 (i) Installation Test) |
- |
|
|
|
| 13.3 (c) Covers,cover plates and actuating members [Cl 13.3]) |
- |
|
|
|
| 13.4 (d) Ordinary switches [Cl 13.4]) |
- |
|
|
|
| 13.5 (e) Rotary switches [Cl 13.5]) |
- |
|
|
|
| 13.6 (f) Screws and other means [Cl 13.6]) |
- |
|
|
|
| 13.7 (g) Combination of switches or switches and socket outlets [Cl 13.7]) |
- |
|
|
|
| 13.8 (h) Assessories combined with switches [Cl. 13.8]) |
- |
|
|
|
| 13.9 (j) Switches other than ordinary switches [Cl. 13.9]) |
- |
|
|
|
| 13.1 (k) Switches to be installed in a box [Cl. 13.10]) |
- |
|
|
|
| 13.11 (l) Surface type switches other than ordinary switch [Cl. 13.11]) |
- |
|
|
|
| 13.12, 13.13, 13.14 (m) Inlet opening [Cl. 13.12.13.13 & 13.14]) |
- |
|
|
|
| 13.15 (q) Requirements for membrane in inlet opening [ Cl. 13.15]) |
- |
|
|
|
| 13.15 (q) Requirements for membrane in inlet opening [ Cl. 13.15]) |
- |
|
|
|
| 13.15 (q) Requirements for membrane in inlet opening [ Cl. 13.15]) |
- |
|
|
|
| 13.15 (q) Requirements for membrane in inlet opening [ Cl. 13.15]) |
- |
|
|
|
| 14 (Mechanism [Cl. 14]) |
- |
|
|
|
| 15.1 (Resistance to Ageing, to Harmful Ingress of water and to Humidity [Cl. 15]: Resistance to Ageing, [Cl. 15.1]) |
- |
|
|
|
| 15.2 (b)Resistance to Harmful ingress of water [Cl. 15.2]) |
- |
|
|
|
| 15.3 (c) Resistance to Humidity [Cl. 15.3]) |
- |
|
|
|
| 16.1 (Insulation resistance [Cl. 16.1]) |
- |
|
|
|
| 16.2 ( Electric Strength [Cl. 16.2]) |
- |
|
|
|
| 17 (Temperature- rise [Cl. 17]) |
- |
|
|
|
| 18 (Marking and breaking Capacity[Cl. 18]) |
- |
|
|
|
| 19 (Normal Operation [Cl. 19] a) General & Operation) |
- |
|
|
|
| 19 (b) Electric Strength) |
- |
|
|
|
| 19 (c)Temperature-rise ) |
- |
|
|
|
| 14.3 (d)Test for arcing and sparking [Cl 14.3]) |
- |
|
|
|
| 19.2 (Normal Operation (For AX type Switches) [Cl. 19.2]) |
- |
|
|
|
| 20 (Mechanical Strength Test [Cl. 20]) |
- |
|
|
|
| 21 (Resistance to Heat [Cl.21]) |
- |
|
|
|
| 22 (Screw, Current Carrying Part And Connection [Cl.22]) |
- |
|
|
|
| 22.1 (i) Screw & Nuts [Cl.22.1]) |
- |
|
|
|
| 22.4 (ii) Screw & rivets [Cl . 22.4]) |
- |
|
|
|
| 22.5 (iv) Current carrying part [Cl.22.5]) |
- |
|
|
|
| 23.2 (Creepage distances, clearances and distance through sealing compound [Cl.23]) |
- |
|
|
|
| 24.1.1 (Resistance to Abnormal Heat & Fire [Cl.24.1] [Glow Wire Test] [Cl.24.1.1]) |
- |
|
|
|
| 24.2 (Resistance to tracking [For Switch other than ordinary] [Cl.24.2]) |
- |
|
|
|
| 6 (Rating) |
- |
|
|
|
| 7 (Classification) |
- |
|
|
|
| 21 (Resistance to Heat [Cl.21]) |
- |
|
|
|
| 21 (Resistance to Heat [Cl.21]) |
- |
|
|
|
| 23.2 (Creepage distances, clearances and distance through sealing compound [Cl.23]) |
- |
|
|
|
| 22.3 (iii) Electrical Connections [Cl.22.3]) |
- |
|
|
|
| 25 of IS 3854 : 1997 (Resistance to rusting) |
- |
|
|
|
| 8 (Marking) |
- |
|
|
|
|
- |
- - |
| 15178 |
BIS, Central Laboratory (CL)
| None
| IS 1489 : Part 2 (2015) |
Portland - Pozzolana cement - Specification: Part 2 calcined clay based |
- |
Rs.8420/- View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 7 -Table 2- i (Fineness 4031 Part 2) |
- |
|
|
|
| 7 -Table 2- ii- a (Expansion by Le Chatelier- 4031 Part 3) |
- |
|
|
|
| 7 -Table 2- ii- b (Expansion by Autoclave- 4031 Part 3) |
- |
|
|
|
| 7 -Table 2- iii- a (Setting Time Initial- 4031 Part 5) |
- |
|
|
|
| 7 -Table 2-iii- b (Setting Time Final- 4031 Part 5) |
- |
|
|
|
| 7 -Table 2- iv- a (Compressive Strength At 72 hrs ± 1 hr - IS 4031 Part 6) |
- |
|
|
|
| 7 -Table 2- iv- b (Compressive Strength At 168 hrs ± 2 hr - IS 4031 Part 6) |
- |
|
|
|
| 7 -Table 2- iv- c (Compressive Strength At 672 hrs ± 4 hr - IS 4031 Part 6) |
- |
|
|
|
| 7 -Table 2- vi (Drying Shrinkage- IS 4031 Part 10) |
- |
|
|
|
| 6 - Table - 1 i (Insoluble residue - Cl 7.4 of IS 4032:1985) |
- |
|
|
|
| 6 - Table - 1 ii (Magnesia - Cl 7.2 of IS 4032:1985) |
- |
|
|
|
| 6 - Table - 1 iii (Total Sulphur Content calculated as Sulphuric Anhydride (SO3) - Cl 7.3 of IS 4032:1985) |
- |
|
|
|
| 6 - Table - 1 iv (Loss on ignition - Cl 7.1 of IS 4032:1985) |
- |
|
|
|
| 6 - Table - 1 v (Chloride content - Cl 4.13 of IS 4032:1985) |
- |
|
|
|
| 6 - Table - 1 vi ( Alkali content as (Na2O + 0.658 K2O) - Cl 4.11 of IS 4032:1985) |
- |
|
|
|
|
- |
- Excluding Table 1,Clause 6.1 ,sl. no.(vi) , alkali content; |
| 15179 |
BIS, Southern Regional Laboratory (SRL)
| None
| IS 1785 : Part 1 (1983) |
Specification for plain hard - Drawn steel wire for prestressed concrete: Part 1 cold drawn stress - Relieved wire (Second Revision) |
- |
Rs. 27300.00 (Complete testing charges) Rs. 9300.00 (F View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl 5.1 (Diameter) |
- |
|
|
|
| Cl 6.1 (Tensile Test On UTM) |
- |
|
|
|
| Cl 6.4 (Tensile Test On UTM) |
- |
|
|
|
|
- |
- " 2mt.+2m "
Excluding Except proof load, ductility, stress relaxation & reverse bend test |
| 15180 |
BIS, Central Laboratory (CL)
| None
| IS 1293 (2019) |
Plugs and socket - Outlets of rated Voltage up to and including 250 Volts and rated current up to and including 16 amperes - Specification (Third Revision) |
- |
- View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 6 (Ratings) |
- |
|
|
|
| 6 (Ratings) |
- |
|
|
|
| 6 (Ratings) |
- |
|
|
|
| 7.1.1 (Accessories Classification) |
- |
|
|
|
| 7.1.2 (Accessories Classification) |
- |
|
|
|
| 7.1.3 (Accessories Classification) |
- |
|
|
|
| 7.1.4 (Accessories Classification) |
- |
|
|
|
| 7.2.1 (Socket-Outlets Classification) |
- |
|
|
|
| 7.2.2 (Socket-Outlets Classification) |
- |
|
|
|
| 7.2.3 (Socket-Outlets Classification) |
- |
|
|
|
| 7.2.4 (Socket-Outlets Classification) |
- |
|
|
|
| 7.3 (Plug Classification) |
- |
|
|
|
| 8.1 (MARKING) |
- |
|
|
|
| 8.8 (MARKING) |
- |
|
|
|
| 8.9 (MARKING) |
- |
|
|
|
| 9.1 (CHECKING OF DIMENSIONS) |
- |
|
|
|
| 9.2 (CHECKING OF DIMENSIONS) |
- |
|
|
|
| 10.1 (PROTECTION AGAINST ELECTRIC SHOCK) |
- |
|
|
|
| 10.1 (PROTECTION AGAINST ELECTRIC SHOCK) |
- |
|
|
|
| 10.4 (PROTECTION AGAINST ELECTRIC SHOCK) |
- |
|
|
|
| 10.5 (PROTECTION AGAINST ELECTRIC SHOCK) |
- |
|
|
|
| 10.6 (PROTECTION AGAINST ELECTRIC SHOCK) |
- |
|
|
|
| 10.7 (PROTECTION AGAINST ELECTRIC SHOCK) |
- |
|
|
|
| 11.1 (PROVISIONS FOR EARTHING) |
- |
|
|
|
| 11.2 (PROVISIONS FOR EARTHING) |
- |
|
|
|
| 11.3 (PROVISIONS FOR EARTHING) |
- |
|
|
|
| 11.4 (PROVISIONS FOR EARTHING) |
- |
|
|
|
| 11.5 (PROVISIONS FOR EARTHING) |
- |
|
|
|
| 11.6 (PROVISIONS FOR EARTHING) |
- |
|
|
|
| 12.1.1 (TERMINALS) |
- |
|
|
|
| 12.1.2 (TERMINALS) |
- |
|
|
|
| 12.2.1 (TERMINALS) |
- |
|
|
|
| 12.2.2 (TERMINALS) |
- |
|
|
|
| 12.2.3 (TERMINALS) |
- |
|
|
|
| 12.2.4 (TERMINALS) |
- |
|
|
|
| 12.2.5 (TERMINALS) |
- |
|
|
|
| 12.2.6 (TERMINALS) |
- |
|
|
|
| 12.2.7 (TERMINALS) |
- |
|
|
|
| 12.2.8 (TERMINALS) |
- |
|
|
|
| 12.2.9 (TERMINALS) |
- |
|
|
|
| 12.2.10 (TERMINALS) |
- |
|
|
|
| 12.2.11 (TERMINALS) |
- |
|
|
|
| 12.3.1 (TERMINALS) |
- |
|
|
|
| 12.3.2 (TERMINALS) |
- |
|
|
|
| 12.3.3 (TERMINALS) |
- |
|
|
|
| 12.3.4 (TERMINALS) |
- |
|
|
|
| 12.3.5 (TERMINALS) |
- |
|
|
|
| 12.3.6 (TERMINALS) |
- |
|
|
|
| 12.3.7 (TERMINALS) |
- |
|
|
|
| 12.3.8 (TERMINALS) |
- |
|
|
|
| 12.3.9 (TERMINALS) |
- |
|
|
|
| 12.3.10 (TERMINALS) |
- |
|
|
|
| 12.3.11 (TERMINALS) |
- |
|
|
|
| 12.3.12 (TERMINALS) |
- |
|
|
|
| 13.1 (CONSTRUCTIONS OF FIXED SOCKETOUTLETS) |
- |
|
|
|
| 13.2 (CONSTRUCTIONS OF FIXED SOCKETOUTLETS) |
- |
|
|
|
| 13.3 (CONSTRUCTIONS OF FIXED SOCKETOUTLETS) |
- |
|
|
|
| 13.4 (CONSTRUCTIONS OF FIXED SOCKETOUTLETS) |
- |
|
|
|
| 13.5 (CONSTRUCTIONS OF FIXED SOCKETOUTLETS) |
- |
|
|
|
| 13.6 (CONSTRUCTIONS OF FIXED SOCKETOUTLETS) |
- |
|
|
|
| 13.7 (CONSTRUCTIONS OF FIXED SOCKETOUTLETS) |
- |
|
|
|
| 13.8 (CONSTRUCTIONS OF FIXED SOCKETOUTLETS) |
- |
|
|
|
| 13.9 (CONSTRUCTIONS OF FIXED SOCKETOUTLETS) |
- |
|
|
|
| 13.1 (CONSTRUCTIONS OF FIXED SOCKETOUTLETS) |
- |
|
|
|
| 13.11 (CONSTRUCTIONS OF FIXED SOCKETOUTLETS) |
- |
|
|
|
| 13.12 (CONSTRUCTIONS OF FIXED SOCKETOUTLETS) |
- |
|
|
|
| 13.13 (CONSTRUCTIONS OF FIXED SOCKETOUTLETS) |
- |
|
|
|
| 13.14 (CONSTRUCTIONS OF FIXED SOCKETOUTLETS) |
- |
|
|
|
| 13.15 (CONSTRUCTIONS OF FIXED SOCKETOUTLETS) |
- |
|
|
|
| 13.16 (CONSTRUCTIONS OF FIXED SOCKETOUTLETS) |
- |
|
|
|
| 13.17 (CONSTRUCTIONS OF FIXED SOCKETOUTLETS) |
- |
|
|
|
| 13.18 (CONSTRUCTIONS OF FIXED SOCKETOUTLETS) |
- |
|
|
|
| 13.19 (CONSTRUCTIONS OF FIXED SOCKETOUTLETS) |
- |
|
|
|
| 13.2 (CONSTRUCTIONS OF FIXED SOCKETOUTLETS) |
- |
|
|
|
| 13.21 (CONSTRUCTIONS OF FIXED SOCKETOUTLETS) |
- |
|
|
|
| 13.22 (CONSTRUCTIONS OF FIXED SOCKETOUTLETS) |
- |
|
|
|
| 13.23 (CONSTRUCTIONS OF FIXED SOCKETOUTLETS) |
- |
|
|
|
| 14.1 (CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
|
|
|
| 14.2 (CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
|
|
|
| 14.3 (CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
|
|
|
| 14.4 (CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
|
|
|
| 14.5 (CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
|
|
|
| 14.6 (CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
|
|
|
| 14.7 (CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
|
|
|
| 14.8 (CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
|
|
|
| 14.9 (CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
|
|
|
| 14.1 (CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
|
|
|
| 14.11 (CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
|
|
|
| 14.12 (CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
|
|
|
| 14.13 (CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
|
|
|
| 14.14 (CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
|
|
|
| 14.15 (CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
|
|
|
| 14.16 (CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
|
|
|
| 14.17 (CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
|
|
|
| 14.18 (CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
|
|
|
| 14.19 (CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
|
|
|
| 14.2 (CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
|
|
|
| 14.21 (CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
|
|
|
| 14.22 (CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
|
|
|
| 14.23 (CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
|
|
|
| 14.23.1 (CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
|
|
|
| 14.23.2 (CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
|
|
|
| 14.24 (CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
|
|
|
| 14.25 (CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
|
|
|
| 14.26 (CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
|
|
|
| 15 (INTERLOCKED SOCKET-OUTLETS) |
- |
|
|
|
| 16.1 (RESISTANCE TO AGEING,) |
- |
|
|
|
| 16.2 (RESISTANCE TO HARMFUL INGRESS OF WATER AND TO HUMIDITY) |
- |
|
|
|
| 16.3 (Resistance to Humidity) |
- |
|
|
|
| 17.1 (INSULATION RESISTANCE AND ELECTRIC STRENGTH) |
- |
|
|
|
| 17.2 (INSULATION RESISTANCE AND ELECTRIC STRENGTH) |
- |
|
|
|
| 19 (TEMPERATURE RISE) |
- |
|
|
|
| 20 (BREAKING CAPACITY) |
- |
|
|
|
| 21 (NORMAL OPERATION) |
- |
|
|
|
| 21 (NORMAL OPERATION) |
- |
|
|
|
| 21 (NORMAL OPERATION) |
- |
|
|
|
| 22.1 (Verification of the Maximum Withdrawal Force) |
- |
|
|
|
| 22.2 (Verification of Minimum Withdrawal Force) |
- |
|
|
|
| 23.1 (FLEXIBLE CABLES AND THEIR CONNECTION) |
- |
|
|
|
| 23.3 (FLEXIBLE CABLES AND THEIR CONNECTION) |
- |
|
|
|
| 23.4 (FLEXIBLE CABLES AND THEIR CONNECTION) |
- |
|
|
|
| 24.1 (MECHANICAL STRENGTH
For all kinds of fixed socket-outlets
) |
- |
|
|
|
| 24.1 (MECHANICAL STRENGTH
For Plug
(1) with enclosures, covers or bodies of thermoplastic or elastomeric material) |
- |
|
|
|
| 24.1 (MECHANICAL STRENGTH
For surface mounting boxes) |
- |
|
|
|
| 24.2 (MECHANICAL STRENGTH
For portable single socket-outlets:
1) with enclosures, covers or bodies other than thermoplastic or elastomeric material) |
- |
|
|
|
| 24.2 (MECHANICAL STRENGTH
For portable multiple and combined socket outlets:
1) with enclosures, covers and bodies of elastomeric or thermoplastic material) |
- |
|
|
|
| 24.2 (MECHANICAL STRENGTH
For plug
1) with enclosures, covers and bodies other than elastomeric or thermoplastic material) |
- |
|
|
|
| 24.2 (MECHANICAL STRENGTH
For plug
1) with enclosures, covers and bodies of elastomeric or thermoplastic material) |
- |
|
|
|
| 24.3 (MECHANICAL STRENGTH
for fixed socket-outlets with a main part intended to be mounted directly on a surface) |
- |
|
|
|
| 24.4 (MECHANICAL STRENGTH
For portable single socket-outlets:
1) with enclosures, covers or bodies of thermoplastic or elastomeric material) |
- |
|
|
|
| 24.4 (MECHANICAL STRENGTH
For portable multiple and combined socket outlets:
1) with enclosures, covers and bodies of elastomeric or thermoplastic material) |
- |
|
|
|
| 24.4 (MECHANICAL STRENGTH
For Plug
1) with enclosures, covers and bodies of elastomeric or thermoplastic material) |
- |
|
|
|
| 24.5 (MECHANICAL STRENGTH
For portable single socket-outlets:
1) with enclosures, covers or bodies of thermoplastic or elastomeric material) |
- |
|
|
|
| 24.5 (MECHANICAL STRENGTH
For portable multiple and combined socket outlets:
1) with enclosures, covers and bodies of elastomeric or thermoplastic material) |
- |
|
|
|
| 24.5 (MECHANICAL STRENGTH
For Plug
1) with enclosures, covers and bodies of elastomeric or thermoplastic material) |
- |
|
|
|
| 24.6 (MECHANICAL STRENGTH
For screwed glands of accessories having an IP code higher than IP20) |
- |
|
|
|
| 24.7 (MECHANICAL STRENGTH
For plug pins provided with insulating sleeves) |
- |
|
|
|
| 24.8 (MECHANICAL STRENGTH
For shuttered socket-outlets) |
- |
|
|
|
| 24.9 (MECHANICAL STRENGTH
For portable multiple and combined socket outlets
(1) with enclosures, covers or bodies other than thermoplastic or elastomeric material) |
- |
|
|
|
| 24.1 (MECHANICAL STRENGTH
For Plug
(1) with enclosures, covers or bodies other than thermoplastic or elastomeric material) |
- |
|
|
|
| 24.11 (MECHANICAL STRENGTH
For portable socket-outlets having means for suspension on a wall) |
- |
|
|
|
| 24.12 (MECHANICAL STRENGTH
For portable socket-outlets having means for suspension on a wall) |
- |
|
|
|
| 24.13 (MECHANICAL STRENGTH
For portable socket-outlets having means for suspension on a wall) |
- |
|
|
|
| 24.14.1 (MECHANICAL STRENGTH
For fixed socket-outlets) |
- |
|
|
|
| 24.14.2 (MECHANICAL STRENGTH
For fixed socket-outlets) |
- |
|
|
|
| 25.1 (RESISTANCE TO HEAT
Accessories and surface mounting boxes) |
- |
|
|
|
| 25.2 (RESISTANCE TO HEAT
Parts of insulating material necessary to retain
current-carrying parts of the earthing circuit in position,
as well as parts of the front surface zone of thermoplastic material) |
- |
|
|
|
| 25.3 (RESISTANCE TO HEAT
Parts of insulating material not necessary to retain current-carrying parts and parts of the earthing circuit in position, even though they are in contact with them) |
- |
|
|
|
| 25.4 (RESISTANCE TO HEAT
) |
- |
|
|
|
| 26.1 (SCREWS, CURRENT-CARRYING PARTS AND CONNECTIONS) |
- |
|
|
|
| 27.1 (CREEPAGE DISTANCES, CLEARANCES AND DISTANCES THROUGH SEALING COMPOUND) |
- |
|
|
|
| 27.2 (CREEPAGE DISTANCES, CLEARANCES AND DISTANCES THROUGH SEALING COMPOUND) |
- |
|
|
|
| 27.3 (CREEPAGE DISTANCES, CLEARANCES AND DISTANCES THROUGH SEALING COMPOUND) |
- |
|
|
|
| 28.1.1 (Resistance to Abnormal Heat and to Fire
Glow-Wire Test) |
- |
|
|
|
| 28.1.2 (Resistance to Abnormal Heat and to Fire
for plugs with pins provided with insulating sleeves) |
- |
|
|
|
| 28.2 (Resistance to Tracking
For accessories other than IP code higher than IPX0 parts of insulating material retaining live parts in position) |
- |
|
|
|
| 29 (RESISTANCE TO RUSTING) |
- |
|
|
|
| 30.1 (ADDITIONAL TESTS ON PINS PROVIDED WITH INSULATING SLEEVES
Pressure Test at High Temperature) |
- |
|
|
|
| 30.2 (ADDITIONAL TESTS ON PINS PROVIDED WITH INSULATING SLEEVES
Static Damp Heat Test) |
- |
|
|
|
| 30.3 (ADDITIONAL TESTS ON PINS PROVIDED WITH INSULATING SLEEVES
Tests at Low Temperature) |
- |
|
|
|
| 30.4 (ADDITIONAL TESTS ON PINS PROVIDED WITH INSULATING SLEEVES
Impact Test at Low Temperature) |
- |
|
|
|
| 7.1.5 (Accessories Classification) |
- |
|
|
|
| 8.1 (MARKING) |
- |
|
|
|
| 10.1 (PROTECTION AGAINST ELECTRIC SHOCK) |
- |
|
|
|
| 23.2 (FLEXIBLE CABLES AND THEIR CONNECTION) |
- |
|
|
|
|
- |
- - |