Search by IS Number
Reset
15248 Results
S.No. Lab Name Osl Code Indian Standard No. Product Grade / Type / Size / Designation etc. Testing Charges (Excl. Of Taxes) Validity Date Remark
15211 BIS, Eastern Regional Laboratory (ERL) None IS 2062 (2011) Hot rolled medium and high tensile structural steel - Specification (Seventh Revision) For all grades except for the tests mentioned in remarks 3200 View breakup
-
- -
Mech - NDT tests can be done with Ultrasonic Flaw detector only, specify method if otherwise; for impact test prepared pieces to be sent; Prepared test piece to be sent for Y groove crackability test. Chem- Type of Killed material to be declared, in case applicable.
15212 BIS, Eastern Regional Laboratory (ERL) None IS 12818 (2010) Unplasticized polyvinyl chloride (Pvc - U) screen and casing pipes for bore/tubewells - Specification (Second Revision) All sizes/types Rs.6450.00 View breakup
-
- -
Chemical: All except Effect on Water which is for Pipes above 60 mm Nominal dia and except for the requirement of 'Other Toxic Substances such a di-n-octyl Tin -s-s bis iso-octyl mercapto acetate' and 'butyl stearate'; Mech- All except HST.
15213 BIS, Eastern Regional Laboratory (ERL) None IS 4985 (2000) Unplasticized pvc pipes for potable water supplies - Specification (Third Revision) All sizes/varieties 4550 View breakup
-
- -
Chemical: All except Effect on Water which is for Pipes above 60 mm Nominal dia and except for the requirement of 'Other Toxic Substances such a di-n-octyl Tin -s-s bis iso-octyl mercapto acetate' and 'butyl stearate'; Mech- All except HST.
15214 BIS, Western Regional Laboratory (WRL) None IS 398 : Part 2 (1996) Aluminium conductors for overhead transmission purposes - Specification: Part 2 aluminium conuuctors, galvanized steel - Reinforced (Third Revision) Up to 100 sq mm Please see remarks. View breakup
-
- -
Test facility not available for Cl. 13.9, 13.10 and 13.11 for size 100 sq.mm and above.
15215 BIS, Western Regional Laboratory (WRL) None IS 3854 (1997) Switches for domestic and similar purposes - Specification (Second Revision) - Please see remarks. View breakup
-
- -
Complete TF is available for varieties upto and including 32 A.
15216 BIS, Eastern Regional Laboratory (ERL) None IS 398 : Part 2 (2025) Aluminium Conductor for Overhead Transmission Purposes - Specification Part 2 Aluminium Conductors Galvanized Steel Reinforced (Fourth Revision) - Please see remarks. View breakup
-
- -
"Partial: Up to 80 sq. mm-All Tests excluding Cl 13.15 Corona Test & Cl 13.16 Radio Interference Voltage Test. 100 sq mm and above-All tests excluding Cl 13.12 D.C Resistance test on stranded conductor, Cl 13.13 Surface Condition test, Cl 13.14 Ultimate Tensile Strength Test on Stranded conductor, Cl 13.15 Corona Test & Cl 13.16 Radio Interference Voltage Test."
15217 BIS, Eastern Regional Laboratory (ERL) None IS 1786 (2008) High strength deformed steel bars and wires for concretere inforcement - Specification (Fourth Revision) For all grades except for the tests mentioned in remarks 25780 View breakup
-
- -
Mech - Facility not available for pull out test, total elongation at maximum force. Chem- Declarations to be provided regarding type of 'Killed' material/Micro-alloys/low-alloys/Nitrogen content or any other parameter to be analysed additionally
15218 BIS, Eastern Regional Laboratory (ERL) None IS 1554 : Part 1 (1988) Specification for pvc insulated (Heavy Duty) electric cables: Part 1 for working voltages up to and including 1100 v (Third Revision) Complete for Cat 01(up to 400sq.mm)Except optional test Rs 26700 View breakup
-
- -
For Category-01 and upto 400 sq mm: all tests are available except additional tests. For cat. C1 and C2 : Except oxygen Index,Temperature index, Flame Retardance, Smoke Density,
15219 BIS, Guwahati Branch Laboratory (GBL) None IS 269 (2015) Ordinary portland cement - Specification (Sixth Revision) - - View breakup
-
- -
Qty. required (8+1) kg Except Transverse strength test (optional).
15220 BIS, Western Regional Laboratory (WRL) None IS 694 (2010) Polyvinyl chloride insulated unsheathed and sheathed cables/cords with rigid and flexible conductor for rated voltages up to and including 450/750 v (Fourth Revision) - Please see remarks View breakup
-
- -
Test facility not available for Copper purity test and FR/FRLSH category cables
15221 BIS, Southern Regional Laboratory (SRL) None IS 694 (2010) Polyvinyl chloride insulated unsheathed and sheathed cables/cords with rigid and flexible conductor for rated voltages up to and including 450/750 v (Fourth Revision) PVC Cables except FR & FRLSH Category Please see remarks View breakup
-
- -
" 30 m Excluding Except FR & FRLSH test, Cu Purity test
15222 BIS, Guwahati Branch Laboratory (GBL) None IS 455 (2015) Portland slag cement - Specification - - View breakup
-
- -
Qty. required (8+1) kg Except Transverse Strength Test (Optional).
15223 BIS, Western Regional Laboratory (WRL) None IS 1554 : Part 1 (1988) Specification for pvc insulated (Heavy Duty) electric cables: Part 1 for working voltages up to and including 1100 v (Third Revision) - Rs 26700 View breakup
-
- -
Test facility not available for tests as per Cl. 15.1.1 of C1 and C2 category
15224 BIS, Guwahati Branch Laboratory (GBL) None IS 1489 (Part 1) (2015) Portland pozzolana cement - Specification: Part 1 fly Ash Based - Rs 8420/ View breakup
-
- -
Qty. required (8+1) kg Except Transverse Strength Test (Optional)
15225 BIS, Western Regional Laboratory (WRL) None IS 13334 : Part 1 (2014) Skimmed milk powder - Specification: Part 1 standard grade (Second Revision) - 10430/- View breakup
-
- -
(1) As per Cl. 5.7 The pesticide residues, heavy metals, toxins (aflatoxins and other naturally occurring toxins) and contaminants, if any, in the product shall not exceed the limits as prescribed in the Food Safety and Standards (Contaminants, Toxins and Residues) Regulations, 2011.’
15226 BIS, Bengaluru Branch Laboratory (BNBL) None IS 455 (2015) Portland slag cement - Specification - - View breakup
-
- -
Expect Transverse Strength
15227 BIS, Western Regional Laboratory (WRL) None IS 2124 (2000) Sodium bicarbonate - Specification (Second Revision) - Rs 4660/- for Pure Grade View breakup
Rs 8210/- for Analytical Reagent Grade Rs 4360/- for Refined Grade
- -
-
15228 BIS, Western Regional Laboratory (WRL) None IS 4984 (2016) Polyethylene pipes for water supply - Specification (Fifth Revision) - - View breakup
-
- -
The following test facilities are not available: (1) Internal Pressure creep rupture test (2)Tensile Strength for Butt-fusion (Clause 8.8) (3) Slow Crack Growth rate test (Clause 8.10) (4) Depth of strip (Clause 6.2.1) (5) Carbon Black content ( Clause 8.3) (6) For Size above 250 mm
15229 BIS, Guwahati Branch Laboratory (GBL) None IS 2062 (2011) Hot rolled medium and high tensile structural steel - Specification (Seventh Revision) - 3200 View breakup
-
- -
Qty. required Mech - Three pices of One metre each Chem - 50 gm or 5 pcs of 50 mm i) Except Impact Test, Y-Groove crackability tests (for Gr 250C). ii) Test Facility for all grades mentioned IS 2062: 2011 having quality A, all grades having other quality partial test is available bar upto diameter 20 mm
15230 BIS, Guwahati Branch Laboratory (GBL) None IS 1659 (2004) Block boards - Specification (Fourth Revision) MR/BWP - View breakup
-
- -
Qty. required 1 Nos Test facility available for thickness upto 30 mm
15231 BIS, Patna Branch Laboratory (PBL) None IS 2062 (2011) Hot rolled medium and high tensile structural steel - Specification (Seventh Revision) - 3200 View breakup
-
- -
All test facilities are available as per the IS except- i. Y-Groove Test (Clause 13) ii. Bend Test for thickness above 25 mm (Clause 11) iii. Tests for microalloying elements and Cr, Mo, Ni, Cu Al and B (Clause 8.2) Note: Prepared test piece of size 55 mm x10 mm x10 mm is required for Impact Test (Clause 12) *- The exact sample type, size and quantity may be ascertained from the latest product manual issued by BIS.
15232 BIS, Patna Branch Laboratory (PBL) None IS 1786 (2008) High strength deformed steel bars and wires for concretere inforcement - Specification (Fourth Revision) - 25780 View breakup
-
- -
All test facilities are available as per the IS except- i. Bond/Pull Out Test (Clause 5.7) ii. Total Elongation at Maximum Force (Clause 8.1 and Table 3) iii. Tensile Test of Sizes > 16mm (Clause 8.1 and Table 3) iv. Tests for microalloying elements (Ti, Nb, B, V), Cr, Mo, Cu, Ni and Al (Clause 4.2)
15233 BIS, Patna Branch Laboratory (PBL) None IS 1489 (Part 1) (2015) Portland pozzolana cement - Specification: Part 1 fly Ash Based - - View breakup
-
- -
All test facilities are available as per the IS except Transverse Strength Test (Clause 7 and Table-2) which is an optional test
15234 BIS, Patna Branch Laboratory (PBL) None IS 1659 (2004) Block boards - Specification (Fourth Revision) - - View breakup
-
- -
All test facilities are available as per the IS
15235 BIS, Patna Branch Laboratory (PBL) None IS 269 (2015) Ordinary portland cement - Specification (Sixth Revision) - - View breakup
-
- -
All test facilities are available as per the IS except Transverse Strength Test (Clause 7 and Table-3) which is an optional test
15236 BIS, Patna Branch Laboratory (PBL) None IS 455 (2015) Portland slag cement - Specification - - View breakup
-
- -
All test facilities are available as per the IS except Transverse Strength Test (Clause 7 and Table 2) which is an optional test
15237 BIS, Patna Branch Laboratory (PBL) None IS 12818 (2010) Unplasticized polyvinyl chloride (Pvc - U) screen and casing pipes for bore/tubewells - Specification (Second Revision) - Rs.6450.00 View breakup
-
- -
All test facilities available except Effect on Water (Clause 9.7)
15238 BIS, Eastern Regional Laboratory (ERL) None IS 455 (2015) Portland slag cement - Specification - - View breakup
-
- -
Mech-Facility not available for transverse strength test( optional); Chem-Declaration for chloride regarding end use of cement required as per Table 1, Confirmation for testing Alkali Content required.
15239 BIS, Eastern Regional Laboratory (ERL) None IS 4984 (2016) Polyethylene pipes for water supply - Specification (Fifth Revision) All varieties - View breakup
-
- -
Mech- Except Hydraulic test, Slow Crack Growth Rate and Internal Pressure Creep Rupture test. Fused pipes required to be provided for T/S of butt fusion joints. Prepared test pieces required for density. Chem- Complete
15240 BIS, Eastern Regional Laboratory (ERL) None IS 1489 (Part 1) (2015) Portland pozzolana cement - Specification: Part 1 fly Ash Based - - View breakup
-
- -
Mech- Facility not available for transverse strength test( optional); Chem-Declaration for chloride regarding end use of cement (as per Table 1) and declaration of fly ash content & Confirmation for testing Alkali Content required.

Designed, Developed and Maintained by:

Arohatech IT Services (P) Ltd.

Contact for any query/support: supportlims@bis.gov.in