S.No. Lab Name Osl Code Indian Standard No. Product Grade / Type / Size / Designation etc. Testing Charges (Excl. Of Taxes) Validity Date Remark
15271 BIS, Patna Branch Laboratory (PBL) None IS 10748 (2004) Hot - Rolled steel strip for welded tubes and pipes - Specification (Second Revision) - Please see remarks View breakup
-
- -
All test facilities are available as per the IS except chemical tests for Chromium, Molybdenum,Vanadium, Nickel, Copper, Niobium, Boron, Titanium, Aluminium and Tungsten (Clause 7.2)
15272 BIS, Patna Branch Laboratory (PBL) None IS 1038 (1983) Specification For Steel Doors, Windows And Ventilators - 3000 View breakup
-
- -
All test facilities are available as per the IS
15273 BIS, Southern Regional Laboratory (SRL) None IS 13422 (1992) Disposable surgical rubber gloves specification - Rs.6900.00 View breakup
-
- -
" Mech - 25 pairs, Micro - 3 pairs "
15274 BIS, Northern Regional Laboratory (NRL) None IS 1659 (2004) Block boards - Specification (Fourth Revision) - Please check remarks View breakup
-
- -
Test facility is complete
15275 BIS, Southern Regional Laboratory (SRL) None IS 13334 : Part 2 (2014) Skimmed milk powder - Specification: Part 2 extra grade (First Revision) EXTRA GRADE 10430/- View breakup
-
- -
2X500g Excluding Except Lactate Content
15276 BIS, Eastern Regional Laboratory (ERL) None IS 398 : Part 5 (1992) Aluminium conductor for overhead transmission purposes - Specification: Part 5 aluminium conductors - Galvanized steel - Reinforced for extra high voltage (400 KV And Above) (First Revision) All sizes/varieties 11400 View breakup
Excluding Breaking load on complete conductor, Surface condition test, Corona test and Radio interference test
- -
Elec-Facility not available for surface condition,corona test ,radio interference test, Breaking Load on complete conductor.
15277 BIS, Northern Regional Laboratory (NRL) None IS 2062 (2011) Hot rolled medium and high tensile structural steel - Specification (Seventh Revision) - 3200 View breakup
-
- -
-
15278 BIS, Eastern Regional Laboratory (ERL) None IS 398 : Part 4 (1994) Aluminium conductors for overhead transmission purposes: Part 4 aluminium alloy stranded conductors (Aluminium - Magnesium - Silicon Type) - Specification (Third Revision) Complete facility available upto 100 sq mm only Please see remarks View breakup
For stranded conductors with 7 strands- Rs.1500 For stranded conductors with 19 strands- Rs.3600 For stranded conductors with 37 strands- Rs. 6750 For stranded conductors with 61 strands- Rs. 10650
- -
Elec-Complete facility available upto 100 sq mm only. For Above 100 sq.mm. facility not available for Stress-Strain Test, Surface Condition, Ultimate B/L on stranded conductor.
15279 BIS, Central Laboratory (CL) None IS 694 (2010) Polyvinyl chloride insulated unsheathed and sheathed cables/cords with rigid and flexible conductor for rated voltages up to and including 450/750 v (Fourth Revision) - Please see remarks View breakup
-
- -
Test facility not available for FR, FR-LSH category.
15280 BIS, Central Laboratory (CL) None IS 15658 (2006) Precast concrete blocks for paving - Specification - Rs.15940/- View breakup
-
- -
Excluding -; Abrasion Resistance Test a ( Dry & Wet)
15281 BIS, Central Laboratory (CL) None IS 269 (2015) Ordinary portland cement - Specification (Sixth Revision) - - View breakup
-
- -
Excluding Table 2,Clause 6.1 ,sl. no.(viii) , alkali content;
15282 BIS, Northern Regional Laboratory (NRL) None IS 269 (2015) Ordinary portland cement - Specification (Sixth Revision) - - View breakup
-
- -
Test Facility is complete for Chemical. Test Facility is complete except Transverse Strength Test
15283 BIS, Southern Regional Laboratory (SRL) None IS 12818 (2010) Unplasticized polyvinyl chloride (Pvc - U) screen and casing pipes for bore/tubewells - Specification (Second Revision) - Rs.6450.00 View breakup
Rs 6450/- Excluding effect on water test
- -
" 6 mts, 2 Gaskets and 5 Hardness button Excluding Excl. Tensile test, reistance to external blows at 0°C , Effect on Water, thread gauges
15284 BIS, Central Laboratory (CL) None IS 710 (2010) Marine plywood - Specification (Second Revision) - Rs 11200/- View breakup
-
- -
-
15285 BIS, Central Laboratory (CL) None IS 12786 (1989) Irrigation equipment - Polyethylene pipes for irrigation laterals - Specification - Please see remarks View breakup
-
- -
Excluding Environmental strees cracking resistance test and Cl 7.1 & Table 2 Hydraulic test;
15286 BIS, Central Laboratory (CL) None IS 14151 : Part 2 (2008) Irrigation equipment - Sprinkler pipes - Specification: Part 2 quick coupled polyethylene pipes and fittings (Second Revision) - - View breakup
Rs. 4250/-(Excluding leakage test and Hyd. Proof Test)+Testing charges as per IS 14151(Part 1)
- -
-
15287 BIS, Central Laboratory (CL) None IS 1489 (Part 1) (2015) Portland pozzolana cement - Specification: Part 1 fly Ash Based - - View breakup
-
- -
Excluding Table 1,Clause 6 ,sl. no.(vi) , alkali content;
15288 BIS, Central Laboratory (CL) None IS 4985 (2021) UNPLASTICIZED PVC PIPES FOR POTABLE WATER SUPPLIES SPECIFICATION Fourth Revision - - View breakup
-
- -
Excluding Effect on water
15289 BIS, Central Laboratory (CL) None IS 4984 (2016) Polyethylene pipes for water supply - Specification (Fifth Revision) - - View breakup
-
- -
Excluding Oxidation induction , overall migration, Cl 8.7 density, Cl 7.4.1.2 ovality Cl 8.8 Tensile,Cl 8.9 Elongation at Break;
15290 BIS, Central Laboratory (CL) None IS 2202 : Part 1 (2023) WOODEN FLUSH DOOR SHUTTERS SOLID CORE TYPE SPECIFICATION PART 1 PLYWOOD FACE PANELS Seventh Revision - - View breakup
-
- -
Excluding Test facility not available for Cl 11.2, 11.4, 11.6, 11.8, 11.9;
15291 BIS, Patna Branch Laboratory (PBL) None IS 6003 (2010) Indented Wire For--Prestressed Concrete ” - Rs.4110/- excl. relaxation test View breakup
-
- -
All test facilities are available as per the IS except- i. Ductility Test (Clause 7.3) ii. Reverse Bend Test (Clause 8.5)
15292 BIS, Patna Branch Laboratory (PBL) None IS 7224 (2006) Iodized salt, vacuum evaporated iodized salt and refined iodized salt - Specification (Second Revision) - Rs7440/- View breakup
-
- -
All test facilities are available as per the IS except chemical tests for determining Lead Content (Clause 4.3 and Table 1)
15293 BIS, Patna Branch Laboratory (PBL) None IS 277 (2018) Galvanized steel strips and sheets (Plain And Corrugated) - Specification (Seventh Revision) - - View breakup
-
- -
All test facilities are available as per the IS except tests for - i. Microalloying elements and Aluminium (Clause 5.1) ii. Surface Finish (Clause 9)
15294 BIS, Patna Branch Laboratory (PBL) None IS 11513 (2017) Hot rolled carbon steel strip for cold rolling purposes - Specification (Second Revision) - - View breakup
-
- -
All test facilities are available as per the IS except tests for microalloying elements (Nb, V, Ti and B) and Aluminium (Clause 6.2)
15295 BIS, Patna Branch Laboratory (PBL) None IS 9825 (2003) Chlorine tablets - Specification (Second Revision) - Rs.4330/ View breakup
-
- -
All test facilities are available as per the IS
15296 BIS, Patna Branch Laboratory (PBL) None IS 1011 (2002) Biscuits - Specification (Fourth Revision) - Rs.3280/- View breakup
-
- -
All test facilities are available as per the IS
15297 BIS, Patna Branch Laboratory (PBL) None IS 1759 (1986) Specification for powrahs (Second Revision) - Rs.2100 View breakup
-
- -
All test facilities are available as per the IS except- i. Hardness Test (Clause 5.2) ii. Drop Test Facility With Platform Made of Mild Steel Plate (Clause 10)
15298 BIS, Patna Branch Laboratory (PBL) None IS 278 (2009) Galvanized steel barbed wire for fencing - Specification (Fourth Revision) - - View breakup
-
- -
All test facilities are available as per the IS except Aluminium (Clause 6) Note: Point wire sample before fabrication is required. *- The exact sample type, size and quantity may be ascertained from the latest product manual issued by BIS.
15299 BIS, Patna Branch Laboratory (PBL) None IS 1239 : Part 1 (2004) Steel tubes, tubulars and other wrought steel fittings - Specification: Part 1 steel tubes (Sixth Revision) - Rs. 9200/- Excluding test on joints View breakup
-
- -
All test facilities are available as per the IS except- i. Hydrostatic Test (Clause 13) ii. Tests for microalloying elements i.e.,Chromium, Molybdenum,Vanadium, Nickel, Copper, Niobium, Boron, Titanium and Aluminium (Clause 6.1.1) Note: Sample size of 3m full length (two samples each of preferred size 1.5 m) may be supplied for testing. *- The exact sample type, size and quantity may be ascertained from the latest product manual issued by BIS.
15300 BIS, Patna Branch Laboratory (PBL) None IS 7887 (1992) Mild steel wire rod for general engineering purposes - Specification (First Revision) - Rs.7200/- View breakup
-
- -
All test facilities are available as per the IS except test of Aluminium (Table 1 and Note 2 of Clause 6.1)