| 1891 |
Aaditech Test and Calibration Lab LLP
| 8179926
| IS 302 : Part 2 : Sec 23 (2009) |
Safety of household and similar electrical appliances: Part 2 particular requirements: Sec 23 appliances for skin or hair care (First Revision) |
Their rated voltage being not more than 250 V |
18000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 32(Radiation ,Toxicity and similar hazards) |
- |
0 |
|
- |
| 31(Resistance to Rusting) |
- |
1000 |
|
- |
| 30(Resistance to Heat & Fire) |
- |
1000 |
|
- |
| 29(Clearances, Creepage Distances & Solid Insulation) |
- |
500 |
|
- |
| 28(Screws & Connection) |
- |
500 |
|
- |
| 27(Provision For Earthing) |
- |
500 |
|
- |
| 26(Terminals For External Conductors) |
- |
500 |
|
- |
| 25(Supply Connection & External Flexible Cables and Cords) |
- |
2000 |
|
- |
| 24(Component) |
- |
500 |
|
- |
| 23(Internal wiring) |
- |
1000 |
|
- |
| 22(Construction) |
- |
1000 |
|
- |
| 21(Mechanical strength) |
- |
1000 |
|
- |
| 20(Stability & Mechanical Hazards) |
- |
500 |
|
- |
| 19(Abnormal Operation) |
- |
1000 |
|
- |
| 18(Endurance) |
- |
0 |
|
- |
| 17(Overload Protection/ Overload Protection of Transformers & Associated Circuits) |
- |
0 |
|
- |
| 16(Leakage Current and Electric Strength) |
- |
1000 |
|
- |
| 15(Moisture Resistance) |
- |
2000 |
|
- |
| 14(Transient Over Voltage) |
- |
0 |
|
- |
| 13(Leakage Current and Electric Strength at Operating Temperature) |
- |
1000 |
|
- |
| 11(Temperature Rise/Heating) |
- |
1000 |
|
- |
| 10(Power Input
& Current) |
- |
500 |
|
- |
| 9(Starting Of Motor Operated Appliances) |
- |
0 |
|
- |
| 8(Protection against Electric Shock/ Protection against Access to Live Parts) |
- |
500 |
|
- |
| 7(Marking/ Marking & Instructions) |
- |
500 |
|
- |
| 6(Classification) |
- |
500 |
|
- |
| 22.32(CONSTRUCTION) |
- |
0 |
|
- |
| 19.11.4.1(Electrostatic discharges) |
- |
0 |
|
- |
| 19.11.4.2(Radiated fields) |
- |
0 |
|
- |
| 19.11.4.3(Fast transient bursts) |
- |
0 |
|
- |
| 19.11.4.4(Surge immunity test) |
- |
0 |
|
- |
| 19.11.4.5(Immunity to conducted discharges) |
- |
0 |
|
- |
| 19.11.4.6(Class 3 Voltage dips and interruptions) |
- |
0 |
|
- |
| 19.11.4.7(Harmonics) |
- |
0 |
|
- |
| 32(Radiation ,Toxicity and similar hazards) |
- |
0 |
|
- |
| 31(Resistance to Rusting) |
- |
0 |
|
- |
| 30(Resistance to Heat & Fire) |
- |
0 |
|
- |
| 29(Clearances, Creepage Distances & Solid Insulation) |
- |
0 |
|
- |
| 28(Screws & Connection) |
- |
0 |
|
- |
| 27(Provision For Earthing) |
- |
0 |
|
- |
| 26(Terminals For External Conductors) |
- |
0 |
|
- |
| 25(Supply Connection & External Flexible Cables and Cords) |
- |
0 |
|
- |
| 24(Component) |
- |
0 |
|
- |
| 23(Internal wiring) |
- |
0 |
|
- |
| 22(Construction) |
- |
0 |
|
- |
| 21(Mechanical strength) |
- |
0 |
|
- |
| 20(Stability & Mechanical Hazards) |
- |
0 |
|
- |
| 19(Abnormal Operation) |
- |
0 |
|
- |
| 18(Endurance) |
- |
0 |
|
- |
| 17(Overload Protection/ Overload Protection of Transformers & Associated Circuits) |
- |
0 |
|
- |
| 16(Leakage Current and Electric Strength) |
- |
0 |
|
- |
| 15(Moisture Resistance) |
- |
0 |
|
- |
| 14(Transient Over Voltage) |
- |
0 |
|
- |
| 13(Leakage Current and Electric Strength at Operating Temperature) |
- |
0 |
|
- |
| 11(Temperature Rise/Heating) |
- |
0 |
|
- |
| 10(Power Input
& Current) |
- |
0 |
|
- |
| 9(Starting Of Motor Operated Appliances) |
- |
0 |
|
- |
| 8(Protection against Electric Shock/ Protection against Access to Live Parts) |
- |
0 |
|
- |
| 7(Marking/ Marking & Instructions) |
- |
0 |
|
- |
| 6(Classification) |
- |
0 |
|
- |
| 22.32(CONSTRUCTION) |
- |
0 |
|
- |
| 19.11.4.1(Electrostatic discharges) |
- |
0 |
|
- |
| 19.11.4.2(Radiated fields) |
- |
0 |
|
- |
| 19.11.4.3(Fast transient bursts) |
- |
0 |
|
- |
| 19.11.4.4(Surge immunity test) |
- |
0 |
|
- |
| 19.11.4.5(Immunity to conducted discharges) |
- |
0 |
|
- |
| 19.11.4.6(Class 3 Voltage dips and interruptions) |
- |
0 |
|
- |
| 19.11.4.7(Harmonics) |
- |
0 |
|
- |
| 32(Radiation ,Toxicity and similar hazards) |
- |
0 |
|
- |
| 31(Resistance to Rusting) |
- |
0 |
|
- |
| 30(Resistance to Heat & Fire) |
- |
0 |
|
- |
| 29(Clearances, Creepage Distances & Solid Insulation) |
- |
0 |
|
- |
| 28(Screws & Connection) |
- |
0 |
|
- |
| 27(Provision For Earthing) |
- |
0 |
|
- |
| 26(Terminals For External Conductors) |
- |
0 |
|
- |
| 25(Supply Connection & External Flexible Cables and Cords) |
- |
0 |
|
- |
| 24(Component) |
- |
0 |
|
- |
| 23(Internal wiring) |
- |
0 |
|
- |
| 22(Construction) |
- |
0 |
|
- |
| 21(Mechanical strength) |
- |
0 |
|
- |
| 20(Stability & Mechanical Hazards) |
- |
0 |
|
- |
| 19(Abnormal Operation) |
- |
0 |
|
- |
| 18(Endurance) |
- |
0 |
|
- |
| 17(Overload Protection/ Overload Protection of Transformers & Associated Circuits) |
- |
0 |
|
- |
| 16(Leakage Current and Electric Strength) |
- |
0 |
|
- |
| 15(Moisture Resistance) |
- |
0 |
|
- |
| 14(Transient Over Voltage) |
- |
0 |
|
- |
| 13(Leakage Current and Electric Strength at Operating Temperature) |
- |
0 |
|
- |
| 11(Temperature Rise/Heating) |
- |
0 |
|
- |
| 10(Power Input
& Current) |
- |
0 |
|
- |
| 9(Starting Of Motor Operated Appliances) |
- |
0 |
|
- |
| 8(Protection against Electric Shock/ Protection against Access to Live Parts) |
- |
0 |
|
- |
| 7(Marking/ Marking & Instructions) |
- |
0 |
|
- |
| 6(Classification) |
- |
0 |
|
- |
| 22.32(CONSTRUCTION) |
- |
0 |
|
- |
| 19.11.4.1(Electrostatic discharges) |
- |
0 |
|
- |
| 19.11.4.2(Radiated fields) |
- |
0 |
|
- |
| 19.11.4.3(Fast transient bursts) |
- |
0 |
|
- |
| 19.11.4.4(Surge immunity test) |
- |
0 |
|
- |
| 19.11.4.5(Immunity to conducted discharges) |
- |
0 |
|
- |
| 19.11.4.6(Class 3 Voltage dips and interruptions) |
- |
0 |
|
- |
| 19.11.4.7(Harmonics) |
- |
0 |
|
- |
| 32(Radiation ,Toxicity and similar hazards) |
- |
0 |
|
- |
| 31(Resistance to Rusting) |
- |
0 |
|
- |
| 30(Resistance to Heat & Fire) |
- |
0 |
|
- |
| 29(Clearances, Creepage Distances & Solid Insulation) |
- |
0 |
|
- |
| 28(Screws & Connection) |
- |
0 |
|
- |
| 27(Provision For Earthing) |
- |
0 |
|
- |
| 26(Terminals For External Conductors) |
- |
0 |
|
- |
| 25(Supply Connection & External Flexible Cables and Cords) |
- |
0 |
|
- |
| 24(Component) |
- |
0 |
|
- |
| 23(Internal wiring) |
- |
0 |
|
- |
| 22(Construction) |
- |
0 |
|
- |
| 21(Mechanical strength) |
- |
0 |
|
- |
| 20(Stability & Mechanical Hazards) |
- |
0 |
|
- |
| 19(Abnormal Operation) |
- |
0 |
|
- |
| 18(Endurance) |
- |
0 |
|
- |
| 17(Overload Protection/ Overload Protection of Transformers & Associated Circuits) |
- |
0 |
|
- |
| 16(Leakage Current and Electric Strength) |
- |
0 |
|
- |
| 15(Moisture Resistance) |
- |
0 |
|
- |
| 14(Transient Over Voltage) |
- |
0 |
|
- |
| 13(Leakage Current and Electric Strength at Operating Temperature) |
- |
0 |
|
- |
| 11(Temperature Rise/Heating) |
- |
0 |
|
- |
| 10(Power Input
& Current) |
- |
0 |
|
- |
| 9(Starting Of Motor Operated Appliances) |
- |
0 |
|
- |
| 8(Protection against Electric Shock/ Protection against Access to Live Parts) |
- |
0 |
|
- |
| 7(Marking/ Marking & Instructions) |
- |
0 |
|
- |
| 6(Classification) |
- |
0 |
|
- |
| 22.32(CONSTRUCTION) |
- |
0 |
|
- |
| 19.11.4.1(Electrostatic discharges) |
- |
0 |
|
- |
| 19.11.4.2(Radiated fields) |
- |
0 |
|
- |
| 19.11.4.3(Fast transient bursts) |
- |
0 |
|
- |
| 19.11.4.4(Surge immunity test) |
- |
0 |
|
- |
| 19.11.4.5(Immunity to conducted discharges) |
- |
0 |
|
- |
| 19.11.4.6(Class 3 Voltage dips and interruptions) |
- |
0 |
|
- |
| 19.11.4.7(Harmonics) |
- |
0 |
|
- |
| 32(Radiation ,Toxicity and similar hazards) |
- |
0 |
|
- |
| 31(Resistance to Rusting) |
- |
0 |
|
- |
| 30(Resistance to Heat & Fire) |
- |
0 |
|
- |
| 29(Clearances, Creepage Distances & Solid Insulation) |
- |
0 |
|
- |
| 28(Screws & Connection) |
- |
0 |
|
- |
| 27(Provision For Earthing) |
- |
0 |
|
- |
| 26(Terminals For External Conductors) |
- |
0 |
|
- |
| 25(Supply Connection & External Flexible Cables and Cords) |
- |
0 |
|
- |
| 24(Component) |
- |
0 |
|
- |
| 23(Internal wiring) |
- |
0 |
|
- |
| 22(Construction) |
- |
0 |
|
- |
| 21(Mechanical strength) |
- |
0 |
|
- |
| 20(Stability & Mechanical Hazards) |
- |
0 |
|
- |
| 19(Abnormal Operation) |
- |
0 |
|
- |
| 18(Endurance) |
- |
0 |
|
- |
| 17(Overload Protection/ Overload Protection of Transformers & Associated Circuits) |
- |
0 |
|
- |
| 16(Leakage Current and Electric Strength) |
- |
0 |
|
- |
| 15(Moisture Resistance) |
- |
0 |
|
- |
| 14(Transient Over Voltage) |
- |
0 |
|
- |
| 13(Leakage Current and Electric Strength at Operating Temperature) |
- |
0 |
|
- |
| 11(Temperature Rise/Heating) |
- |
0 |
|
- |
| 10(Power Input
& Current) |
- |
0 |
|
- |
| 9(Starting Of Motor Operated Appliances) |
- |
0 |
|
- |
| 8(Protection against Electric Shock/ Protection against Access to Live Parts) |
- |
0 |
|
- |
| 7(Marking/ Marking & Instructions) |
- |
0 |
|
- |
| 6(Classification) |
- |
0 |
|
- |
| 22.32(CONSTRUCTION) |
- |
0 |
|
- |
| 19.11.4.1(Electrostatic discharges) |
- |
0 |
|
- |
| 19.11.4.2(Radiated fields) |
- |
0 |
|
- |
| 19.11.4.3(Fast transient bursts) |
- |
0 |
|
- |
| 19.11.4.4(Surge immunity test) |
- |
0 |
|
- |
| 19.11.4.5(Immunity to conducted discharges) |
- |
0 |
|
- |
| 19.11.4.6(Class 3 Voltage dips and interruptions) |
- |
0 |
|
- |
| 19.11.4.7(Harmonics) |
- |
0 |
|
- |
| 32(Radiation ,Toxicity and similar hazards) |
- |
0 |
|
- |
| 31(Resistance to Rusting) |
- |
0 |
|
- |
| 30(Resistance to Heat & Fire) |
- |
0 |
|
- |
| 29(Clearances, Creepage Distances & Solid Insulation) |
- |
0 |
|
- |
| 28(Screws & Connection) |
- |
0 |
|
- |
| 27(Provision For Earthing) |
- |
0 |
|
- |
| 26(Terminals For External Conductors) |
- |
0 |
|
- |
| 25(Supply Connection & External Flexible Cables and Cords) |
- |
0 |
|
- |
| 24(Component) |
- |
0 |
|
- |
| 23(Internal wiring) |
- |
0 |
|
- |
| 22(Construction) |
- |
0 |
|
- |
| 21(Mechanical strength) |
- |
0 |
|
- |
| 20(Stability & Mechanical Hazards) |
- |
0 |
|
- |
| 19(Abnormal Operation) |
- |
0 |
|
- |
| 18(Endurance) |
- |
0 |
|
- |
| 17(Overload Protection/ Overload Protection of Transformers & Associated Circuits) |
- |
0 |
|
- |
| 16(Leakage Current and Electric Strength) |
- |
0 |
|
- |
| 15(Moisture Resistance) |
- |
0 |
|
- |
| 14(Transient Over Voltage) |
- |
0 |
|
- |
| 13(Leakage Current and Electric Strength at Operating Temperature) |
- |
0 |
|
- |
| 11(Temperature Rise/Heating) |
- |
0 |
|
- |
| 10(Power Input
& Current) |
- |
0 |
|
- |
| 9(Starting Of Motor Operated Appliances) |
- |
0 |
|
- |
| 8(Protection against Electric Shock/ Protection against Access to Live Parts) |
- |
0 |
|
- |
| 7(Marking/ Marking & Instructions) |
- |
0 |
|
- |
| 6(Classification) |
- |
0 |
|
- |
| 22.32(CONSTRUCTION) |
- |
0 |
|
- |
| 19.11.4.1(Electrostatic discharges) |
- |
0 |
|
- |
| 19.11.4.2(Radiated fields) |
- |
0 |
|
- |
| 19.11.4.3(Fast transient bursts) |
- |
0 |
|
- |
| 19.11.4.4(Surge immunity test) |
- |
0 |
|
- |
| 19.11.4.5(Immunity to conducted discharges) |
- |
0 |
|
- |
| 19.11.4.6(Class 3 Voltage dips and interruptions) |
- |
0 |
|
- |
| 19.11.4.7(Harmonics) |
- |
0 |
|
- |
|
28 Aug, 2027 |
- Included w.e.f.03.09.2025
Exclusion
"19.11.4.1 TO 19.11.4.7 EMI/EMC
32 (Radiation ,Toxicity and similar hazards)
24 (Component)" |
| 1892 |
ALPHA TEST HOUSE PVT LTD, BAHADURGARH
| 8185306
| IS 16270 (2023) |
Secondary cells and batteries for solar photovoltaic application - General requirements and methods of test |
- |
550000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl-4.1(Photovoltaic Energy System) |
- |
550000 |
|
- |
| Cl-4.2(Secondary Cells and Batteries) |
- |
550000 |
|
- |
| Cl-4.3(General Operating Conditions) |
- |
550000 |
|
- |
| Cl-4.3.8(Storage) |
- |
550000 |
|
- |
| Cl-4.3.9(Operating Temperature) |
- |
550000 |
|
- |
| Cl-5.1(Mechanical Endurance) |
- |
550000 |
|
- |
| Cl-5.2(Charge Efficiency) |
- |
550000 |
|
- |
| Cl-5.3(Deep Discharge Protection) |
- |
550000 |
|
- |
| Cl-5.4(Marking) |
- |
550000 |
|
- |
| Cl-5.5(Safety) |
- |
550000 |
|
- |
| Cl-5.6(Documentation) |
- |
550000 |
|
- |
| Cl-6(Functional characteristice) |
- |
550000 |
|
- |
| Cl-7(General test conditions) |
- |
550000 |
|
- |
| Cl-8.1(Capacity Test) |
- |
550000 |
|
- |
| Cl-8.2(Endurance Test) |
- |
550000 |
|
- |
| Cl-8.3(Charge Retention Test) |
- |
550000 |
|
- |
| Cl-8.4(Cycle Endurance in Photovoltaic Application (Extreme Conditions)) |
- |
550000 |
|
- |
| Cl-8.5(Sulphation Test (Applicable for Lead Acid Batteries only)) |
- |
550000 |
|
- |
| Cl-8.6(Water Loss Test (Valid for Flooded Lead Acid Batteries only)) |
- |
550000 |
|
- |
| Cl-9.1(Type Tests) |
- |
550000 |
|
- |
| Cl-9.2(Acceptance Test) |
- |
550000 |
|
- |
| 4.3.7.1(Specific gravity) |
- |
550000 |
|
- |
|
08 May, 2028 |
- Included w.e.f. 28.08.2025 |
| 1893 |
SHRI KRISHNA TEST HOUSE PVT LTD (142)
| 8185606
| IS 26 (2024) |
Tin ingot - Specification (fifth revision) |
All |
10000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl-5(Suppy of material) |
- |
10000 |
|
- |
| Cl-6(Raw Materials and manufacture) |
- |
10000 |
|
- |
| Cl-7.1, 7.2 Table-1(Sn, Min) |
- |
10000 |
|
- |
| Cl-7.1, 7.2 Table-1(Sb, Max) |
- |
10000 |
|
- |
| Cl-7.1, 7.2 Table-1(As, Max) |
- |
10000 |
|
- |
| Cl-7.1, 7.2 Table-1(Bi, Max) |
- |
10000 |
|
- |
| Cl-7.1, 7.2 Table-1(Cd, Max) |
- |
10000 |
|
- |
| Cl-7.1, 7.2 Table-1(Cu, Max) |
- |
10000 |
|
- |
| Cl-7.1, 7.2 Table-1(Fe, Max) |
- |
10000 |
|
- |
| Cl-7.1, 7.2 Table-1(Pb, Max) |
- |
10000 |
|
- |
| Cl-7.1, 7.2 Table-1(Al, Max) |
- |
10000 |
|
- |
| Cl-7.1, 7.2 Table-1(Zn, Max) |
- |
10000 |
|
- |
| Cl-7.1, 7.2 Table-1(Total of All Impurities, Max) |
- |
10000 |
|
- |
| Cl-7.2(Chemical analysis) |
- |
10000 |
|
- |
| Cl-8(Surface condition of ingots) |
- |
10000 |
|
- |
| Cl-9(Shape and mass of the ingots) |
- |
10000 |
|
- |
| Cl-14(Marking) |
- |
10000 |
|
- |
|
13 May, 2028 |
- Included w.e.f 31.07.2025 |
| 1894 |
Planet Electro Labs Private Limited (407)
| 8174226
| IS 17980 (2022) |
Maximum Power Point Tracking Efficiency of Grid Connected Photovoltaic Inverters (First Revision) |
UPTO 200KW |
450000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl-4.1 (a)(Static MPPT efficiency) |
- |
200000 |
|
- |
| Cl-4.1 (b)(Dynamic MPPT efficiency) |
- |
250000 |
|
- |
| Cl-4.1 (a)(Static MPPT efficiency) |
- |
250000 |
|
- |
| Cl-4.1 (b)(Dynamic MPPT efficiency) |
- |
250000 |
|
- |
| Cl-4.1 (a)(Static MPPT efficiency) |
- |
40000 |
|
- |
| Cl-4.1 (b)(Dynamic MPPT efficiency) |
- |
40000 |
|
- |
| Cl-4.3.2(Measurement procedure) |
- |
40000 |
|
- |
| Cl-4.4(Test conditions for dynamic MPPT efficiency) |
- |
40000 |
|
- |
| Cl-5(Calculation of the overall efficiency) |
- |
40000 |
|
- |
| A.1.1 in Annex A(PV generator simulator-General) |
- |
40000 |
|
- |
| A.1.2 in Annex A(Requirements on the static characteristic) |
- |
40000 |
|
- |
| A.1.3 in Annex A(Requirement on the transient stability) |
- |
40000 |
|
- |
| A.1.4 in Annex A(Requirements on the dynamic characteristic) |
- |
40000 |
|
- |
| A.1.5 in Annex A(Requirements on electrical characteristic) |
- |
30000 |
|
- |
| A.2 in Annex A(AC power supply) |
- |
20000 |
|
- |
| B.2 in Annex B(Test sequence with ramps 10 % – 50 % GSTC) |
- |
40000 |
|
- |
| B.3 in Annex B(Test sequence with ramps 30 % – 100 % GSTC) |
- |
40000 |
|
- |
| B.4 in Annex B(Start-up and shut-down test with slow ramps) |
- |
40000 |
|
- |
| C.1 in Annex C(PV generator model for MPPT performance tests) |
- |
40000 |
|
- |
| C.2 in Annex C(Alternative PV generator model for MPPT performance tests) |
- |
40000 |
|
- |
| D.1 in Annex D(European efficiency) |
- |
40000 |
|
- |
| D.2 in Annex D(CEC efficiency) |
- |
40000 |
|
- |
| E.1 in Annex E(static MPPT and conversion efficiency- General) |
- |
40000 |
|
- |
| E.2 in Annex E(Re-normalisation of output power PAC to the rated output power PAC,r) |
- |
40000 |
|
- |
| E.3 in Annex E(Representation of the conversion efficiency in terms of normalised rated output power) |
- |
40000 |
|
- |
| E.4 in Annex E(Interpolation on normative nodes) |
- |
40000 |
|
- |
| Cl-4.3.3(Evaluation – Calculation of static MPPT efficiency) |
- |
40000 |
|
- |
|
05 Nov, 2026 |
- Included w.e.f. 04.11.2025 |
| 1895 |
URS PRODUCTS AND TESTING PVT. LTD. (A29), NOIDA
| 8168906
| IS 737 (2024) |
WROUGHT ALUMINIUM AND ALUMINIUM ALLOY SHEET AND STRIP FOR GENERAL ENGINEERING PURPOSES SPECIFICATION (Fifth Revision) |
- |
14500 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl. 4(Ordering Information - IS 737) |
- |
14500 |
|
- |
| Cl. 4 (a)(Grade/ Thickness - IS 737) |
- |
14500 |
|
- |
| Cl. 4 (b)(Condition - IS 737) |
- |
14500 |
|
- |
| Cl. 4 (c)(Quantity in Kg - IS 737) |
- |
14500 |
|
- |
| Cl. 4 (d)(Size - Thickness X Width X Length (T X W X L) in mm for sheets and (T X W) in mm for Strips/ Coils - IS 737) |
- |
14500 |
|
- |
| Cl. 4 (e)(Coil ID and Coil Weight for Strips/ Coils - IS 737) |
- |
14500 |
|
- |
| Cl. 4 (f)(Core/ Spool Requirement for Coils - IS 737) |
- |
14500 |
|
- |
| Cl. 4 (g)(Packing Mode - IS 737) |
- |
14500 |
|
- |
| Cl. 5(Supply for Material - IS 737/ IS 10259) |
- |
14500 |
|
- |
| Cl. 6(Freedom from Defects - IS 737) |
- |
14500 |
|
- |
| Cl. 7(Chemical Composition - IS 504/ IS 504 (Part-1 to 12)/ IS 504 (Part-13 to 16)/ ASTM E 1251/ IS 11035) |
- |
14500 |
|
- |
| Cl. 7(Si - IS 504 (Part-1)/ ASTM E 1251/ IS 11035) |
- |
14500 |
|
- |
| Cl. 7(Fe - IS 504 (Part-2)/ ASTM E 1251/ IS 11035) |
- |
14500 |
|
- |
| Cl. 7(Cu - IS 504 (Part-3)/ ASTM E 1251/ IS 11035) |
- |
14500 |
|
- |
| Cl. 7(Mn - IS 504 (Part-5)/ ASTM E 1251/ IS 11035) |
- |
14500 |
|
- |
| Cl. 7(Mg - IS 504 (Part-6)/ ASTM E 1251/ IS 11035) |
- |
14500 |
|
- |
| Cl. 7(Cr - IS 504 (Part-8)/ ASTM E 1251/ IS 11035) |
- |
14500 |
|
- |
| Cl. 7(Zn - IS 504 (Part-4)/ ASTM E 1251/ IS 11035) |
- |
14500 |
|
- |
| Cl. 7(Ti - IS 504 (Part-11)/ ASTM E 1251/ IS 11035) |
- |
14500 |
|
- |
| Cl. 7(Others (Each) - IS 504/ IS 504 (Part-1 to 12)/ IS 504 (Part-13 to 16)/ ASTM E 1251/ IS 11035) |
- |
14500 |
|
- |
| Cl. 7(Others (Total) - IS 504/ IS 504 (Part-1 to 12)/ IS 504 (Part-13 to 16)/ ASTM E 1251/ IS 11035) |
- |
14500 |
|
- |
| Cl. 7(Al - IS 504) |
- |
14500 |
|
- |
| Cl. 8(Mechanical Properties - IS 1608 (Part-1)) |
- |
14500 |
|
- |
| Cl. 8.1(0.2% Proof Stress - IS 1608 (Part-1)) |
- |
14500 |
|
- |
| Cl. 8.1(Tensile Strength - IS 1608 (Part-1)) |
- |
14500 |
|
- |
| Cl. 8.1(Elongation on 50mm Gauge Length - IS 1608 (Part-1)) |
- |
14500 |
|
- |
| Cl. 8.2(Bend Test - IS 1599) |
- |
14500 |
|
- |
| Cl. 9(Condition - IS 737/ IS 5052) |
- |
14500 |
|
- |
| Cl. 10(Dimensions and Tolerances - IS 737/ IS 2676) |
- |
14500 |
|
- |
| Cl. 11(Selection of Test Samples - IS 737) |
- |
14500 |
|
- |
| Cl. 11.1(Sheet and Strip of Aluminium or Non - Heat Treatable Aluminium Alloy - IS 737) |
- |
14500 |
|
- |
| Cl. 11.2(Sheet and Strip of Heat - Treatable Aluminium Alloys - IS 737) |
- |
14500 |
|
- |
| Cl. 12(Retests - IS 737/ IS 10259) |
- |
14500 |
|
- |
| Cl. 13(Packaging - IS 737/ IS 10259) |
- |
14500 |
|
- |
| Cl. 13.1(Marking - IS 737) |
- |
14500 |
|
- |
|
26 Sep, 2027 |
- Included w.e.f.01.09.2025 |
| 1896 |
National Test House (NR) - NTH, Ghaziabad
| 8101304
| IS 11544 (1986) |
Specification for slipper, rubber |
- |
12000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 3.2.6(Thickness of components) |
- |
0 |
|
- |
| 3.2.5(Type of Thread) |
- |
0 |
|
- |
| 3.2.4(Colour fasntess to washing) |
- |
0 |
|
- |
| 3.2.4(Picks per cm) |
- |
0 |
|
- |
| 3.2.4(End per cm) |
- |
0 |
|
- |
| 3.2.4(Mass per unit area) |
- |
0 |
|
- |
| 3.2(Flexural endurance) |
- |
0 |
|
- |
| 3.2(Hardness after ageing) |
- |
0 |
|
- |
| 3.2(Relative density ) |
- |
0 |
|
- |
| 3.1(Shape & Design) |
- |
0 |
|
- |
| 3.2.2(Bottom Filling Material) |
- |
0 |
|
- |
| 3.2.4.1(Weave of fabrics) |
- |
0 |
|
- |
| 3.2.7(vulcanized process) |
- |
0 |
|
- |
| 3.2.8(Workmanship and Finish -) |
- |
0 |
|
- |
| 3.2.9(Preservation -) |
- |
0 |
|
- |
| Cl. 4, Cl. 4.1, Cl 4.2, Cl. 4.3(Marking and packing) |
- |
0 |
|
- |
| Cl. 4, Cl. 4.1,Cl 4.2(Marking and packing) |
- |
0 |
|
- |
| 3.2(Hardness (IRHD)) |
- |
0 |
|
- |
|
26 Oct, 2025 |
- Included w.e.f.18.08.2025 |
| 1897 |
EKO PRO ENGINEERS PRIVATE LIMITED (32/41), GHAZIABAD
| 9179706
| IS 5676 (1995) |
Moulded solid rubber soles and heels - SpecificatlOn (Second Revision) |
ALL |
7500 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 5/5.3/5.3.1(REQUIREMENTS- Construction) |
- |
700 |
|
- |
| 5/5.1(REQUIREMENTS-General) |
- |
500 |
|
- |
| 5/5.2- Fig. 1 to 5(REQUIREMENTS-Design) |
- |
500 |
|
- |
| 5/5.5- Table1(REQUIREMENTS-Thickness) |
- |
400 |
|
- |
| 5/5.6/5.6.1(REQUIREMENTS-Channel) |
- |
400 |
|
- |
| 5/5.7- Table2(REQUIREMENTS- Physical Requirements-
as per IS 3400 (Part 1, Part 2, Part 4, Part 9, Part 10, Part 16)) |
- |
700 |
|
- |
| 5/5.3/5.3.1(REQUIREMENTS- Construction) |
- |
400 |
|
- |
| 5/5.1(REQUIREMENTS-General) |
- |
400 |
|
- |
| 5/5.2- Fig. 1 to 5(REQUIREMENTS-Design) |
- |
400 |
|
- |
| 5/5.5- Table1(REQUIREMENTS-Thickness) |
- |
400 |
|
- |
| 5/5.6/5.6.1(REQUIREMENTS-Channel) |
- |
400 |
|
- |
| 5/5.7- Table2(REQUIREMENTS- Physical Requirements-
as per IS 3400 (Part 1, Part 2, Part 4, Part 9, Part 10, Part 16)) |
- |
700 |
|
- |
| 5/5.3/5.3.1(REQUIREMENTS- Construction) |
- |
700 |
|
- |
| 5/5.1(REQUIREMENTS-General) |
- |
400 |
|
- |
| 5/5.2- Fig. 1 to 5(REQUIREMENTS-Design) |
- |
400 |
|
- |
| 5/5.5- Table1(REQUIREMENTS-Thickness) |
- |
400 |
|
- |
| 5/5.6/5.6.1(REQUIREMENTS-Channel) |
- |
400 |
|
- |
| 5/5.7- Table2(REQUIREMENTS- Physical Requirements-
as per IS 3400 (Part 1, Part 2, Part 4, Part 9, Part 10, Part 16)) |
- |
700 |
|
- |
| 6(Marking and packing) |
- |
500 |
|
- |
| 8.1(Test methods) |
- |
800 |
|
- |
| 8.3(Measurement of thickness) |
- |
400 |
|
- |
| Cl.6.1,6.2,6.3(Marking and packing) |
- |
500 |
|
- |
| 8.1(Test Methods) |
- |
800 |
|
- |
| Cl.8.3(Measurement of thickness ") |
- |
400 |
|
- |
| 5.5 (Amendment 1)(Thickness) |
- |
400 |
|
- |
| 5.7 Table 2 i) (Amendment 1)(Relative Density) |
- |
500 |
|
- |
| 5.7, Table 2 ii) (Amendment 1)(Hardness, degree, Shore A) |
- |
400 |
|
- |
| 5.7, Table 2 iv) (Amendment 1)(Abrasion Resistance at applied force of 10 N) |
- |
700 |
|
- |
| 5.7, Table 2 v) (Amendment 1)(Tensile strength) |
- |
1000 |
|
- |
| 5.7, Table 2 vi) (Amendment 1)(Elongation at break) |
- |
1000 |
|
- |
| 5.7, Table 2 vii) (Amendment 1)(Tear strength (average force)) |
- |
1000 |
|
- |
| 5.7, Table 2 iii) (Amendment 1)(Flexing resistance) |
- |
1000 |
|
- |
|
26 Aug, 2027 |
- Included w.e.f.18.08.2025 |
| 1898 |
HT Product Services Private Limited, Noida
| 8175006
| IS 2083 (2024) |
FLASHLIGHT- SPECIFICATION (Third Revision) |
- |
50000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4.1(Materials) |
- |
2000 |
|
- |
| 6(Dimensions) |
- |
2000 |
|
- |
| 8.1.1(Samples for Type Tests) |
- |
2000 |
|
- |
| 8.2(Acceptance Tests) |
- |
2000 |
|
- |
| 8.2(Acceptance Tests) |
- |
2000 |
|
- |
| 8.2.1(Sample for Acceptance Tests) |
- |
2000 |
|
- |
| 8.3(Routine Tests) |
- |
2000 |
|
- |
| 10(TEST FOR MECHANICAL ASSEMBLY) |
- |
2000 |
|
- |
| 11(DROP TEST) |
- |
2000 |
|
- |
| 12.1(Dry Heat Tests) |
- |
2000 |
|
- |
| 12.2(Damp Heat (Accelerated) Test) |
- |
2000 |
|
- |
| 12.3(Dry Cold Test (Optional)) |
- |
2000 |
|
- |
| 13(LIFE TEST FOR SWITCH) |
- |
2000 |
|
- |
| 14.1(INSULATION RESISTANCE TEST) |
- |
2000 |
|
- |
| 15(TEST FOR CONTACT RESISTANCE OF THE SWITCH) |
- |
2000 |
|
- |
| 16(LIGHT DISTRIBUTION TEST) |
- |
2000 |
|
- |
| 17(LUMEN DEPRECIATION TEST FOR LED FLASHLIGHT) |
- |
2000 |
|
- |
| 18(CIRCUIT CURRENT OF LED FLASHLIGHT) |
- |
2000 |
|
- |
| 21(TEST FOR INGRESS PROTECTION) |
- |
2000 |
|
- |
| 24(THERMAL TEST) |
- |
2000 |
|
- |
| 7(MARKING) |
- |
2000 |
|
- |
| 19(TEST FOR CHARGING CURRENT IN
BUILT-IN RECHARGEABLE BATTERY
OPERATED FLASHLIGHTS) |
- |
2000 |
|
- |
| 22(OVER CHARGE PROTECTION IN
RECHARGEABLE FLASHLIGHTS WITH
BUILT-IN CHARGER/SEPARATE CHARGER/
SOLAR CHARGER) |
- |
2000 |
|
- |
| 24(THERMAL TEST) |
- |
2000 |
|
- |
|
03 Dec, 2026 |
- Included w.e.f. 28.08.2025
Exclusion: "9 (TEST FOR FINISH)
20 (PHOTOBIOLOGICAL SAFETY)" |
| 1899 |
Gravitas Laboratories Private Limited, Greater Noida
| 8182606
| IS 15658 (2021) |
Concrete Paving Blocks - Specification ( First Revision ) |
- |
12500 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Clause 7.3 & 9.1.4, Table 3, SI No. (vi)(Freeze Thaw durability (Visual Rating of specimen after 50 cycles) |
- |
0 |
|
- |
| Clause 7.3 & 9.1.4, Table 3, SI No. (vi)(Freeze Thaw durability (Visual Rating of specimen after 25 cycles) |
- |
0 |
|
- |
| Clause 7.3 & 9.1.4, Table 3, SI No. (vi)(Freeze Thaw durability (Visual Rating of specimen after 10 cycles) |
- |
0 |
|
- |
| Clause 7.3 & 9.1.4, Table 3, SI No. (vi)(Freeze Thaw durability (Cumulative Weight losses of specimen after 10, 25 & 50 cycles) |
- |
0 |
|
- |
| Clause 7.3 & 9.1.4, Table 3, SI No. (vi)(Freeze Thaw durability (Weight losses of specimen after 50 cycles) |
- |
0 |
|
- |
| Clause 7.3 & 9.1.4, Table 3, SI No. (vi)(Freeze Thaw durability (Weight losses of specimen after 25 cycles) |
- |
0 |
|
- |
| Clause 7.3 & 9.1.4, Table 3, SI No. (vi)(Freeze Thaw durability (Weight losses of specimen after 10 cycles) |
- |
0 |
|
- |
| Clause 7.3, Annex G(Average Breaking Load) |
- |
1000 |
|
- |
| Clause 7.3, Annex G(Individual Breaking Load) |
- |
1000 |
|
- |
| Clause 7.3, Annex F(Average Failure Load per unit Length) |
- |
1000 |
|
- |
| Clause 7.3, Annex F(Individual Failure Load per unit Length) |
- |
1000 |
|
- |
| Clause 7.3 & 9.1.4, Table 3, SI No. (v) b)(Average Flexural strength ) |
- |
1000 |
|
- |
| Clause 7.3 & 9.1.4, Table 3, SI No. (v) a)(Indivdual Flexural strength (i)) |
- |
1000 |
|
- |
| Clause 7.3 & 9.1.4, Table 3, SI No. (iv) b)(Average Tensile splitting strength ) |
- |
1000 |
|
- |
| Clause 7.3 & 9.1.4, Table 3, SI No. (iv) a)(Indivdual Tensile splitting strength (i)) |
- |
1000 |
|
- |
| Clause 7.3 & 9.1.4, Table 3, SI No. (iii) b) ii)(Wet Abrasion resistance (Average of three test specimens)) |
- |
3000 |
|
- |
| Clause 7.3 & 9.1.4, Table 3, SI No. (iii) b) i)( Indivdual Wet Abrasion Resistance ) |
- |
3000 |
|
- |
| Clause 7.3 & 9.1.4, Table 3, SI No. (iii) a) ii)(Dry Abrasion resistance (Average of three test specimens)) |
- |
3000 |
|
- |
| Clause 7.3 & 9.1.4, Table 3, SI No. (iii) a) i)( Indivdual Dry Abrasion Resistance ) |
- |
3000 |
|
- |
| Clause 7.3 & 9.1.4, Table 3, SI No. (ii) b)(Compressive strength (Average of eight test specimens)) |
- |
3000 |
|
- |
| Clause 7.3 & 9.1.4, Table 3, SI No. (ii) a)(Indivdual Compressive strength (i)) |
- |
3000 |
|
- |
| Clause 7.3 & 9.1.4, Table 3, SI No. (i) b)(Water absorption (Average of three test specimens)) |
- |
3000 |
|
- |
| Clause 7.3 & 9.1.4, Table 3, SI No. (i) a)( Indivdual Water absorption) |
- |
3000 |
|
- |
| Clause 7.2 & 9.1.3, Table 2, SI No. (ix)(Deviation from squareness) |
- |
1500 |
|
- |
| Clause 7.2 & 9.1.3, Table 2, SI No. (viii)(Indivdual Ratio of wearing face area and Plan area (Asw/Asp)) |
- |
1500 |
|
- |
| Clause 7.2 & 9.1.3, Table 2, SI No. (viii)(Ratio of wearing face area and Plan area (Asw/Asp)) |
- |
1500 |
|
- |
| Clause 7.2 & 9.1.3, Table 2, SI No. (vii)(Indivdual Plan Area (Asp)) |
- |
1500 |
|
- |
| Clause 7.2 & 9.1.3, Table 2, SI No. (vii)(Plan Area (Asp)) |
- |
1500 |
|
- |
| Clause 7.2 & 9.1.3, Table 2, SI No. (vi)(Indivdual Thickness of wearing Layer) |
- |
1500 |
|
- |
| Clause 7.2 & 9.1.3, Table 2, SI No. (vi)(Thickness of wearing Layer) |
- |
1500 |
|
- |
| Clause 7.2 & 9.1.3, Table 2, SI No. (v)(Indivdual Arris/chamfer, Depth) |
- |
1500 |
|
- |
| Clause 7.2 & 9.1.3, Table 2, SI No. (v)(Arris/chamfer, Depth) |
- |
1500 |
|
- |
| Clause 7.2 & 9.1.3, Table 2, SI No. (v)(Indivdual Arris/chamfer, Width) |
- |
1500 |
|
- |
| Clause 7.2 & 9.1.3, Table 2, SI No. (v)(Arris/chamfer, Width) |
- |
1500 |
|
- |
| Clause 7.2, Table No. 2, SI No. (iv)
(Indivdual Aspect Ratio, L/Th) |
- |
1500 |
|
- |
| Clause 7.2, Table No. 2, SI No. (iv)
(Aspect Ratio, L/Th) |
- |
1500 |
|
- |
| Clause 7.2, Table No. 2, SI No. (iii)
(Indivdual Thickness, Th) |
- |
1500 |
|
- |
| Clause 7.2, Table No. 2, SI No. (iii)
(Thickness, Th) |
- |
1500 |
|
- |
| Clause 7.2, Table No. 2, SI No. (ii)
(Indivdual Length, L) |
- |
1500 |
|
- |
| Clause 7.2, Table No. 2, SI No. (ii)
(Length, L) |
- |
1500 |
|
- |
| Clause 7.2, Table No. 2, SI No. (i)
(Indivdual Width, W) |
- |
1500 |
|
- |
| Clause 7.2, Table No. 2, SI No. (i)
(Width, W) |
- |
1500 |
|
- |
| Clauses 7.1.2 & 9.1.2
(Visual Inspection) |
- |
1000 |
|
- |
| Clause 7.1.1
(General Quality) |
- |
1000 |
|
- |
| 7.2- TABLE-2- (i) IS-15658 (Annex-B)(Individual Width - Lower) |
- |
1500 |
|
- |
| 7.2- TABLE-2- (i) IS-15658 (Annex-B)(Average Width -Lower) |
- |
1500 |
|
- |
| 7.2- TABLE-2- (i) IS-15658 (Annex-B)(Individual Width - Higher) |
- |
1500 |
|
- |
| 7.2- TABLE-2- (i) IS-15658 (Annex-B)(Average Width -Higher) |
- |
1500 |
|
- |
| Clause 3.20(Spacer nibs) |
- |
1500 |
|
- |
| 5.4(Coarse and Fine
Aggregates) |
- |
0 |
|
- |
| 5.6(Water) |
- |
0 |
|
- |
| Clause 7.3, Annex G(Average Breaking Load) |
- |
0 |
|
- |
| Clause 7.3, Annex G(Individual Breaking Load) |
- |
0 |
|
- |
| Clause 7.3, Annex F(Average Failure Load per unit Length) |
- |
0 |
|
- |
| Clause 7.3, Annex F(Individual Failure Load per unit Length) |
- |
0 |
|
- |
| Clause 7.3 & 9.1.4, Table 3, SI No. (v) b)(Average Flexural strength ) |
- |
0 |
|
- |
| Clause 7.3 & 9.1.4, Table 3, SI No. (v) a)(Indivdual Flexural strength (i)) |
- |
0 |
|
- |
| Clause 7.3 & 9.1.4, Table 3, SI No. (iv) b)(Average Tensile splitting strength ) |
- |
0 |
|
- |
| Clause 7.3 & 9.1.4, Table 3, SI No. (iv) a)(Indivdual Tensile splitting strength (i)) |
- |
0 |
|
- |
| Clause 7.3 & 9.1.4, Table 3, SI No. (iii) b) ii)(Wet Abrasion resistance (Average of three test specimens)) |
- |
0 |
|
- |
| Clause 7.3 & 9.1.4, Table 3, SI No. (iii) b) i)( Indivdual Wet Abrasion Resistance ) |
- |
0 |
|
- |
| Clause 7.3 & 9.1.4, Table 3, SI No. (iii) a) ii)(Dry Abrasion resistance (Average of three test specimens)) |
- |
0 |
|
- |
| Clause 7.3 & 9.1.4, Table 3, SI No. (iii) a) i)( Indivdual Dry Abrasion Resistance ) |
- |
0 |
|
- |
| Clause 7.3 & 9.1.4, Table 3, SI No. (ii) b)(Compressive strength (Average of eight test specimens)) |
- |
0 |
|
- |
| Clause 7.3 & 9.1.4, Table 3, SI No. (ii) a)(Indivdual Compressive strength (i)) |
- |
0 |
|
- |
| Clause 7.3 & 9.1.4, Table 3, SI No. (i) b)(Water absorption (Average of three test specimens)) |
- |
0 |
|
- |
| Clause 7.3 & 9.1.4, Table 3, SI No. (i) a)( Indivdual Water absorption) |
- |
0 |
|
- |
| Clause 7.2 & 9.1.3, Table 2, SI No. (ix)(Deviation from squareness) |
- |
0 |
|
- |
| Clause 7.2 & 9.1.3, Table 2, SI No. (viii)(Indivdual Ratio of wearing face area and Plan area (Asw/Asp)) |
- |
0 |
|
- |
| Clause 7.2 & 9.1.3, Table 2, SI No. (viii)(Ratio of wearing face area and Plan area (Asw/Asp)) |
- |
0 |
|
- |
| Clause 7.2 & 9.1.3, Table 2, SI No. (vii)(Indivdual Plan Area (Asp)) |
- |
0 |
|
- |
| Clause 7.2 & 9.1.3, Table 2, SI No. (vii)(Plan Area (Asp)) |
- |
0 |
|
- |
| Clause 7.2 & 9.1.3, Table 2, SI No. (vi)(Indivdual Thickness of wearing Layer) |
- |
0 |
|
- |
| Clause 7.2 & 9.1.3, Table 2, SI No. (vi)(Thickness of wearing Layer) |
- |
0 |
|
- |
| Clause 7.2 & 9.1.3, Table 2, SI No. (v)(Indivdual Arris/chamfer, Depth) |
- |
0 |
|
- |
| Clause 7.2 & 9.1.3, Table 2, SI No. (v)(Arris/chamfer, Depth) |
- |
0 |
|
- |
| Clause 7.2 & 9.1.3, Table 2, SI No. (v)(Indivdual Arris/chamfer, Width) |
- |
0 |
|
- |
| Clause 7.2 & 9.1.3, Table 2, SI No. (v)(Arris/chamfer, Width) |
- |
0 |
|
- |
| Clause 7.2, Table No. 2, SI No. (iv)
(Indivdual Aspect Ratio, L/Th) |
- |
0 |
|
- |
| Clause 7.2, Table No. 2, SI No. (iv)
(Aspect Ratio, L/Th) |
- |
0 |
|
- |
| Clause 7.2, Table No. 2, SI No. (iii)
(Indivdual Thickness, Th) |
- |
0 |
|
- |
| Clause 7.2, Table No. 2, SI No. (iii)
(Thickness, Th) |
- |
0 |
|
- |
| Clause 7.2, Table No. 2, SI No. (ii)
(Indivdual Length, L) |
- |
0 |
|
- |
| Clause 7.2, Table No. 2, SI No. (ii)
(Length, L) |
- |
0 |
|
- |
| Clause 7.2, Table No. 2, SI No. (i)
(Indivdual Width, W) |
- |
0 |
|
- |
| Clause 7.2, Table No. 2, SI No. (i)
(Width, W) |
- |
0 |
|
- |
| Clauses 7.1.2 & 9.1.2
(Visual Inspection) |
- |
0 |
|
- |
| Clause 7.1.1
(General Quality) |
- |
0 |
|
- |
| 7.2- TABLE-2- (i) IS-15658 (Annex-B)(Individual Width - Lower) |
- |
0 |
|
- |
| 7.2- TABLE-2- (i) IS-15658 (Annex-B)(Average Width -Lower) |
- |
0 |
|
- |
| 7.2- TABLE-2- (i) IS-15658 (Annex-B)(Individual Width - Higher) |
- |
0 |
|
- |
| 7.2- TABLE-2- (i) IS-15658 (Annex-B)(Average Width -Higher) |
- |
0 |
|
- |
| Clause 3.20(Spacer nibs) |
- |
0 |
|
- |
|
19 Nov, 2027 |
- - |
| 1900 |
SHRI KRISHNA TEST HOUSE PVT LTD (142)
| 8185606
| IS 444 (2025) |
Rubber Hoses, Textile-Reinforced, for General-Purpose Water Applications - Specification (Sixth Revision) |
ALL |
25000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl-5(Material and Construction) |
- |
25000 |
|
- |
| Cl-6.1(Internal diameters and tolerances) |
- |
25000 |
|
- |
| Cl-6.2(Concentricity) |
- |
25000 |
|
- |
| Cl-6.3(Tolerance of length) |
- |
25000 |
|
- |
| Cl-6.4(Minimum thickness of lining and cover) |
- |
25000 |
|
- |
| Cl-7.1, Table-2 (i)(Minimum tensile strength) |
- |
25000 |
|
- |
| Cl-7.1, Table-2 (ii)(Minimum elongation at break) |
- |
25000 |
|
- |
| Cl-7.1, Table-2 (iii)("Resistance to ageing:
Change in tensile strength from original value (max) . Change in elongation at break from original value (max)") |
- |
25000 |
|
- |
| Cl-7.2, Table-3 (i)(Proof pressure at 23 0 C) |
- |
25000 |
|
- |
| Cl-7.2, Table-3 (ii)(Change in length at proof pressure) |
- |
25000 |
|
- |
| Cl-7.2, Table-3 (iii)(Minimum burst pressure) |
- |
25000 |
|
- |
| Cl-7.2, Table-3 (iv)(Adhesion between component) |
- |
25000 |
|
- |
| Cl-7.2, Table-3 (v)(Ozone resistance) |
- |
25000 |
|
- |
| Cl-7.2, Table-3 (vi)(Flexibility at 23ºC) |
- |
25000 |
|
- |
| Cl-7.2, Table-3 (vii)(Low-temperature flexibility) |
- |
25000 |
|
- |
| Cl-8(Marking) |
- |
25000 |
|
- |
|
13 May, 2028 |
- Included w.e.f 31.07.2025 |
| 1901 |
BIS, Eastern Regional Laboratory (ERL)
| None
| IS 18166 (2025) |
Unplasticized Polyvinyl Chloride PVC-U Threaded Column Pipes for Borewells/Tubewells - Specification |
For all nominal size and class |
- View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 5 (COLOUR) |
- |
|
|
|
| 6 (CLASSIFICATION) |
- |
|
|
|
| 7, Table - 2,3,4,7 (DIMENSIONS) |
- |
|
|
|
| 8.3 , Table 5, 6 (Basic Thread Dimensions) |
- |
|
|
|
| 9.1 (Visual Appearance) |
- |
|
|
|
| 9.2 (Resistance to External Blows at 0 °C) |
- |
|
|
|
| 9.4 (Tensile Strength) |
- |
|
|
|
| 9.4 (Elongation at Break) |
- |
|
|
|
| 9.8 (Density) |
- |
|
|
|
| 9.9 (Vicat Softening Temperature) |
- |
|
|
|
| 8.1 (Column Pipes) |
- |
|
|
|
| 8.2 (Column Couplers) |
- |
|
|
|
| 8.4 (Sealing rings and elements made of elastomeric material such as EPDM,) |
- |
|
|
|
| 9.6 (Izod Impact Strength Test) |
- |
|
|
|
| 9.9 (Vicat Softening Temperature) |
- |
|
|
|
| 8.1 (Column Pipes) |
- |
|
|
|
| 8.2 (Column Couplers) |
- |
|
|
|
| 8.4 (Sealing rings and elements made of elastomeric material such as EPDM,) |
- |
|
|
|
| 9.5 , Table- 9 (Ultimate Breaking Load) |
- |
|
|
|
| 9.11 (Hydrostatic Pressure Test) |
- |
|
|
|
| 9.12 (Joint Leak Pressure Test) |
- |
|
|
|
| 9.3 (Flattening Test) |
- |
|
|
|
| 9.7 (Resistance to DCM) |
- |
|
|
|
| 9. 10 (Effect on Water Lead (first extraction)) |
- |
|
|
|
| 9. 10 (Effect on Water Lead (third extraction)) |
- |
|
|
|
| 9. 10 (Effect on Water Dialkyl tin C4 and higher homologues(measured as tin )(third extraction )) |
- |
|
|
|
| 9. 10 (Effect on Water Cadmium (mean of first extraction, second extraction and third extraction)) |
- |
|
|
|
| 9. 10 (Effect on Water Mercury (mean of first extraction, second extraction and third extraction)) |
- |
|
|
|
|
- |
- Except 9.5 Ultimate Breaking Load, 9.6 Izod Impact Strength Test, 9.11 Hydrostatic Pressure Test, 9.12 Joint Leak Pressure Test, 9.3 Flattening Test.
Sample required- 16 pieces pipes approx 1 m (Mechanical- 10 pc and chemical- 6 pc) |
| 1902 |
National Test House (NR) - NTH, Ghaziabad
| 8101304
| IS 6719 (1972) |
Solid Pvc Soles And Heels |
- |
15000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 3.6.1(Hardness ) |
- |
0 |
|
- |
| 3.6 (vi)(Lead (as Pb) ppm) |
- |
0 |
|
- |
| 3.6 (v)(Volatility, percent by means ) |
- |
0 |
|
- |
| 3.6 (iv)(Tear Strength a) Force Part b) Back Part ) |
- |
0 |
|
- |
| 3.6 (iii)(Elongation at break, percent ) |
- |
0 |
|
- |
| 3.6 (ii)(Tensile Strength ) |
- |
0 |
|
- |
| 3.6 (i)(Relative density ) |
- |
0 |
|
- |
| Cl. 3.1,3.2,3.3,3.4,3.5(Material) |
- |
0 |
|
- |
| 6 ,6.1,6.2,6.3(Test Method) |
- |
0 |
|
- |
| Cl. 3.1,3.2,3.3,3.4,3.5(Material) |
- |
0 |
|
- |
| Cl. 6.4(Measurement of thickness) |
- |
0 |
|
- |
| Table 1 (Flexing resistance)(Table 1 (Flexing resistance, Bennewart method, cut growth at the end of 30 000 cycles, mm, Max)) |
- |
0 |
|
- |
| Table 1 (Abrasion resistance)(Abrasion resistance at applied
force of 10 N (volume loss),
mm3, Max) |
- |
0 |
|
- |
| Table 1 Cl. 3.6, Sl No (iii)(Volatility, Percent by mass) |
- |
0 |
|
- |
| Table 1 Cl. 3.6, Sl No (iv)("Lead (as Pb), Shoes for
infants, children and
boys and girls, ppm") |
- |
0 |
|
- |
| Table 1 Cl. 3.6, Sl No (iv)("Lead (as Pb), for other sized shoes, ppm
") |
- |
0 |
|
- |
| 3.6.1(Hardness ) |
- |
0 |
|
- |
| 3.6 (vi)(Lead (as Pb) ppm) |
- |
0 |
|
- |
| 3.6 (v)(Volatility, percent by means ) |
- |
0 |
|
- |
| 3.6 (iv)(Tear Strength a) Force Part b) Back Part ) |
- |
0 |
|
- |
| 3.6 (iii)(Elongation at break, percent ) |
- |
0 |
|
- |
| 3.6 (ii)(Tensile Strength ) |
- |
0 |
|
- |
| 3.6 (i)(Relative density ) |
- |
0 |
|
- |
| Cl. 3.1,3.2,3.3,3.4,3.5(Material) |
- |
0 |
|
- |
| 6 ,6.1,6.2,6.3(Test Method) |
- |
0 |
|
- |
| Cl. 3.1,3.2,3.3,3.4,3.5(Material) |
- |
0 |
|
- |
| Cl. 6.4(Measurement of thickness) |
- |
0 |
|
- |
| Table 1 (Flexing resistance)(Table 1 (Flexing resistance, Bennewart method, cut growth at the end of 30 000 cycles, mm, Max)) |
- |
0 |
|
- |
| Table 1 (Abrasion resistance)(Abrasion resistance at applied
force of 10 N (volume loss),
mm3, Max) |
- |
0 |
|
- |
| Table 1 Cl. 3.6, Sl No (iii)(Volatility, Percent by mass) |
- |
0 |
|
- |
| Table 1 Cl. 3.6, Sl No (iv)("Lead (as Pb), Shoes for
infants, children and
boys and girls, ppm") |
- |
0 |
|
- |
| Table 1 Cl. 3.6, Sl No (iv)("Lead (as Pb), for other sized shoes, ppm
") |
- |
0 |
|
- |
| 3.6.1(Hardness ) |
- |
0 |
|
- |
| 3.6 (vi)(Lead (as Pb) ppm) |
- |
0 |
|
- |
| 3.6 (v)(Volatility, percent by means ) |
- |
0 |
|
- |
| 3.6 (iv)(Tear Strength a) Force Part b) Back Part ) |
- |
0 |
|
- |
| 3.6 (iii)(Elongation at break, percent ) |
- |
0 |
|
- |
| 3.6 (ii)(Tensile Strength ) |
- |
0 |
|
- |
| 3.6 (i)(Relative density ) |
- |
0 |
|
- |
| Cl. 3.1,3.2,3.3,3.4,3.5(Material) |
- |
0 |
|
- |
| 6 ,6.1,6.2,6.3(Test Method) |
- |
0 |
|
- |
| Cl. 3.1,3.2,3.3,3.4,3.5(Material) |
- |
0 |
|
- |
| Cl. 6.4(Measurement of thickness) |
- |
0 |
|
- |
| Table 1 (Flexing resistance)(Table 1 (Flexing resistance, Bennewart method, cut growth at the end of 30 000 cycles, mm, Max)) |
- |
0 |
|
- |
| Table 1 (Abrasion resistance)(Abrasion resistance at applied
force of 10 N (volume loss),
mm3, Max) |
- |
0 |
|
- |
| Table 1 Cl. 3.6, Sl No (iii)(Volatility, Percent by mass) |
- |
0 |
|
- |
| Table 1 Cl. 3.6, Sl No (iv)("Lead (as Pb), Shoes for
infants, children and
boys and girls, ppm") |
- |
0 |
|
- |
| Table 1 Cl. 3.6, Sl No (iv)("Lead (as Pb), for other sized shoes, ppm
") |
- |
0 |
|
- |
|
26 Oct, 2025 |
- Included w.e.f.18.08.2025 |
| 1903 |
DELHI TEST HOUSE (65) KUNDLI-2 SONIPAT
| 9138006
| IS 398 : Part 2 (2025) |
Aluminium Conductor for Overhead Transmission Purposes - Specification Part 2 Aluminium Conductors Galvanized Steel Reinforced (Fourth Revision) |
-- |
38450 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl-6(Material) |
- |
500 |
|
- |
| Cl-6.1.1(chemical composition of high carbon steel) |
- |
2000 |
|
- |
| Cl-6.2(zinc used for galvanizing) |
- |
1000 |
|
- |
| Cl-7(Freedom From Defects) |
- |
500 |
|
- |
| Cl-8.1(Wires-Nominal Sizes) |
- |
500 |
|
- |
| Cl-8.2(Aluminum Conductors, Galvanized Steel- Reinforced) |
- |
500 |
|
- |
| Cl-9.1(Joint in Wires) |
- |
500 |
|
- |
| Cl-9.2(Aluminium Wires) |
- |
500 |
|
- |
| Cl-9.3(Galvanized Steel Wires) |
- |
1000 |
|
- |
| Cl-10.2(Lay Ratio of Aluminium Conductors Galvanized Steel-Reinforced) |
- |
750 |
|
- |
| Cl-13.3(Conductor- Visual examination) |
- |
200 |
|
- |
| Cl- 13.5(Conductor- Measurement of lay ratio/direction of lay) |
- |
2500 |
|
- |
| Cl- 13.12(Conductor- d.c. Resistance test on stranded conductor) |
- |
3500 |
|
- |
| Cl- 13.14(Conductor- Ultimate tensile strength test on stranded conductor) |
- |
5000 |
|
- |
| Cl- 13.13(Conductor- Surface condition test on stranded conductor) |
- |
6000 |
|
- |
| Cl- 13.15(Conductor- Corona test (for conductors intended for use at 400 kV and above voltage level for a.c. and ± 320 kV and above voltage level for d.c.)) |
- |
0 |
|
- |
| Cl-13.16(Conductor- Radio interference voltage test) |
- |
0 |
|
- |
| Cl-13.4(Aluminium wires-Measurement of diameter) |
- |
1000 |
|
- |
| Cl- 13.6(Aluminium wires -Breaking load test) |
- |
1000 |
|
- |
| Cl- 13.8(Aluminium wires- Wrapping test) |
- |
500 |
|
- |
| Cl- 13.9(Aluminium wires- d.c. resistance test) |
- |
2000 |
|
- |
| Cl- 13.11(Aluminium wires Procedure qualification test on welded joint of aluminium strands) |
- |
500 |
|
- |
| Cl- 13.4(Steel wires- Measurement of diameter) |
- |
500 |
|
- |
| Cl- 13.6(Steel wires- Breaking load test) |
- |
1000 |
|
- |
| Cl- 13.7(Steel wires- Ductility test) |
- |
1000 |
|
- |
| Cl- 13.8(Steel wires- Wrapping test) |
- |
1000 |
|
- |
| Cl- 13.10(Steel wires- Galvanizing test) |
- |
3000 |
|
- |
| Cl-13.7.1(Torsion Test) |
- |
500 |
|
- |
| Cl-13.7.2(Elongation Test) |
- |
500 |
|
- |
| Cl-11.1(Standard Length) |
- |
500 |
|
- |
| Cl-11.2(Random Lengths) |
- |
500 |
|
- |
|
31 Dec, 2026 |
- Included w.e.f 09.10.2025
Exclusion: Cl- 13.15 (Conductor- Corona test (for conductors intended for use at 400 kV and above voltage level for a.c. and ± 320 kV and above voltage level for d.c.)), Cl-13.16 (Conductor- Radio interference voltage test) |
| 1904 |
IEC TEST LABS LLP
| 8165726
| IS 398 : Part 2 (1996) |
Aluminium conductors for overhead transmission purposes - Specification: Part 2 aluminium conuuctors, galvanized steel - Reinforced (Third Revision) |
- |
140000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 8.1.1 & 13.2 Table-1 (mech)(Diameter of Aluminium Wires Before Stranding) |
- |
1000 |
|
Rs. 20000/- [Up to 100 Sq.mm],
Rs. 110000/- [150 & 200 Sq.mm]
Rs. 120000/- [400 & 560 Sq.mm]
Rs. 140000/- [420 & 520 Sq.mm] |
| 8.1.1 & 13.2 Table 2 (mech)(Diameter of Steel Wires Before Stranding) |
- |
1000 |
|
- |
| 8.1.1 & 13.2 Table-1 (mech)(Diameter of Aluminium Wires After Stranding) |
- |
1000 |
|
- |
| 8.1.1 & 13.2 Table 2 (mech)(Diameter of Steel Wires After Stranding) |
- |
1000 |
|
- |
| 10 (elec)(Stranding) |
- |
1000 |
|
- |
| 10 (elec)(Stranding) |
- |
1000 |
|
- |
| 10 (elec)(Stranding) |
- |
1000 |
|
- |
| 10 (mech)(Stranding) |
- |
1000 |
|
- |
| 13.3 Table 1 (mech)(Breaking Load of Aluminium Wires Before Stranding) |
- |
1000 |
|
- |
| 13.3 Table 2 (mech)(Breaking Load of Steel Wires Before Stranding) |
- |
1000 |
|
- |
| 13.3 Table 1 (mech)(Breaking Load of Aluminium Wires After Stranding) |
- |
1000 |
|
- |
| 13.3 Table 2 (mech)(Breaking Load of Steel Wires After Stranding) |
- |
1000 |
|
- |
| 13.4.1 (mech)(Ductility by Torsion Test before stranding) |
- |
1000 |
|
- |
| 13.4.1 (mech)(Ductility by Torsion Test before stranding) |
- |
1000 |
|
- |
| 13.4.1 (mech)(Ductility by Torsion Test after stranding) |
- |
1000 |
|
- |
| 13.4.1 (mech)(Ductility by Torsion Test after stranding) |
- |
1000 |
|
- |
| 13.4.2 (elec)(Ductility by Elongation Test before stranding) |
- |
1000 |
|
- |
| 13.4.2 (elec)(Ductility by Elongation Test after stranding) |
- |
1000 |
|
- |
| 13.5.1 (mech)(Wrapping Test Aluminium Wires Before Stranding) |
- |
1000 |
|
- |
| 13.5.1 (mech)(Wrapping Test Aluminium Wires After Stranding) |
- |
1000 |
|
- |
| 13.5.2 (mech)(Wrapping Test Galvanized Steel Wires Before Stranding) |
- |
1000 |
|
- |
| 13.5.2 (mech)(Wrapping Test Galvanized Steel Wires After Stranding) |
- |
1000 |
|
- |
| 13.6 (elec)(Resistance test-Aluminium wire before Stranding) |
- |
1000 |
|
- |
| 13.6 (elec)(Resistance test-Aluminium wire after stranding) |
- |
1000 |
|
- |
| 13.7.2 (chem)(Mass of Zinc coating) |
- |
1000 |
|
- |
| 13.7.2 (chem)(Uniformity of Zinc coating) |
- |
1000 |
|
- |
| 13.8 Table-4 (mech)(Lay Ratio- Aluminium Wire Outermost Layer) |
- |
1000 |
|
- |
| 13.8 Table-4 (mech)(Lay Ratio- Aluminium Wire Layer Immediately Beneath Outermost Layer) |
- |
1000 |
|
- |
| 13.8 Table-4 (mech)(Lay Ratio- Aluminium Wire Innermost Layer of Conductors with 3 Aluminium Wire Layers) |
- |
1000 |
|
- |
| 13.8 Table-4 (mech)(Lay Ratio- Steel Core (6 Wire Layer)) |
- |
1000 |
|
- |
| 13.9 (elec)(Surface condition test) |
- |
20000 |
|
- |
| 13.10 (elec)(Ultimate breaking load) |
- |
20000 |
|
- |
| 13.11 (elec)(Stress-strain test) |
- |
80000 |
|
- |
| 13.8 Table-4 (elec)(Lay Ratio- Steel Core (6 Wire Layer)) |
- |
1000 |
|
- |
| 13.8 Table-4 (elec)(Lay Ratio- Steel Core (6 Wire Layer)) |
- |
1000 |
|
- |
| 13.8 Table-4 (elec)(Lay Ratio- Aluminium Wire Innermost Layer of Conductors with 3 Aluminium Wire Layers) |
- |
1000 |
|
- |
| 13.8 Table-4 (elec)(Lay Ratio- Aluminium Wire Layer Immediately Beneath Outermost Layer) |
- |
1000 |
|
- |
| 13.8 Table-4 (elec)(Lay Ratio- Aluminium Wire Outermost Layer) |
- |
1000 |
|
- |
| 13.7.2 (elec)(Uniformity of Zinc coating) |
- |
1000 |
|
- |
| 13.7.2 (elec)(Mass of Zinc coating) |
- |
1000 |
|
- |
| 13.5.2 (elec)(Wrapping Test Galvanized Steel Wires After Stranding) |
- |
1000 |
|
- |
| 13.5.2 (elec)(Wrapping Test Galvanized Steel Wires Before Stranding) |
- |
1000 |
|
- |
| 13.5.1 (elec)(Wrapping Test Aluminium Wires After Stranding) |
- |
1000 |
|
- |
| 13.5.1 (elec)(Wrapping Test Aluminium Wires Before Stranding) |
- |
1000 |
|
- |
| 13.4.1 (elec)(Ductility by Torsion Test after stranding) |
- |
1000 |
|
- |
| 13.4.1 (elec)(Ductility by Torsion Test after stranding) |
- |
1000 |
|
- |
| 13.4.1 (elec)(Ductility by Torsion Test after stranding) |
- |
1000 |
|
- |
| 13.4.1 (elec)(Ductility by Torsion Test after stranding) |
- |
1000 |
|
- |
| 13.3 Table 2 (elec)(Breaking Load of Steel Wires After Stranding) |
- |
1000 |
|
- |
| 13.3 Table 1 (elec)(Breaking Load of Steel Wires After Stranding) |
- |
1000 |
|
- |
| 13.3 Table 2 (elec)(Breaking Load of Steel Wires Before Stranding) |
- |
1000 |
|
- |
| 13.3 Table 1 (elec)(Breaking Load of Steel Wires Before Stranding) |
- |
1000 |
|
- |
| 8.1.1 & 13.2 Table-1 (elec)(Diameter of Aluminium Wires Before Stranding) |
- |
1000 |
|
- |
| 8.1.1 & 13.2 Table 2 (elec)(Diameter of Steel Wires Before Stranding) |
- |
1000 |
|
- |
| 8.1.1 & 13.2 Table-1 (elec)(Diameter of Aluminium Wires After Stranding) |
- |
1000 |
|
- |
| 8.1.1 & 13.2 Table 2 (elec)(Diameter of Steel Wires After Stranding) |
- |
1000 |
|
- |
| 13.8 Table-4 (elec)(Lay Ratio- Steel Core (6 Wire Layer)) |
- |
1000 |
|
- |
| 13.8 Table-4 (elec)(Lay Ratio- Aluminium Wire Innermost Layer of Conductors with 3 Aluminium Wire Layers) |
- |
1000 |
|
- |
| 13.8 Table-4 (elec)(Lay Ratio- Aluminium Wire Layer Immediately Beneath Outermost Layer) |
- |
1000 |
|
- |
| 13.8 Table-4 (elec)(Lay Ratio- Aluminium Wire Outermost Layer) |
- |
1000 |
|
- |
| 13.7.2 (elec)(Uniformity of Zinc coating) |
- |
1000 |
|
- |
| 13.7.2 (elec)(Mass of Zinc coating) |
- |
1000 |
|
- |
| 13.5.2 (elec)(Wrapping Test Galvanized Steel Wires After Stranding) |
- |
1000 |
|
- |
| 13.5.2 (elec)(Wrapping Test Galvanized Steel Wires Before Stranding) |
- |
1000 |
|
- |
| 13.5.1 (elec)(Wrapping Test Aluminium Wires After Stranding) |
- |
1000 |
|
- |
| 13.5.1 (elec)(Wrapping Test Aluminium Wires Before Stranding) |
- |
1000 |
|
- |
| 13.4.1 (elec)(Ductility by Torsion Test after stranding) |
- |
1000 |
|
- |
| 13.4.1 (elec)(Ductility by Torsion Test after stranding) |
- |
1000 |
|
- |
| 13.4.1 (elec)(Ductility by Torsion Test before stranding) |
- |
1000 |
|
- |
| 13.4.1 (elec)(Ductility by Torsion Test before stranding) |
- |
1000 |
|
- |
| 13.3 Table 2 (elec)(Breaking Load of Steel Wires After Stranding) |
- |
1000 |
|
- |
| 13.3 Table 1 (elec)(Breaking Load of Aluminium Wires After Stranding) |
- |
1000 |
|
- |
| 13.3 Table 2 (elec)(Breaking Load of Steel Wires Before Stranding) |
- |
1000 |
|
- |
| 13.3 Table 1 (elec)(Breaking Load of Aluminium Wires Before Stranding) |
- |
1000 |
|
- |
| 10 (elec)(Stranding) |
- |
1000 |
|
- |
| 8.1.1 & 13.2 Table 2 (elec)(Diameter of Steel Wires After Stranding) |
- |
1000 |
|
- |
| 8.1.1 & 13.2 Table-1 (elec)(Diameter of Aluminium Wires After Stranding) |
- |
1000 |
|
- |
| 8.1.1 & 13.2 Table 2 (elec)(Diameter of Steel Wires Before Stranding) |
- |
1000 |
|
- |
| 8.1.1 & 13.2 Table-1 (elec)(Diameter of Aluminium Wires Before Stranding) |
- |
1000 |
|
- |
| 4.1(Resistivity) |
- |
2000 |
|
- |
| 4.2(Density) |
- |
2000 |
|
- |
| 4.3(Constant-Mass Temperature Coefficient of Resistance) |
- |
2000 |
|
- |
| 4.4(Coefficient of Linear Expansion) |
- |
2000 |
|
- |
| 5.1(Density) |
- |
2000 |
|
- |
| 5.2(Coefficient of Linear Expansion) |
- |
2000 |
|
- |
| 14.2(a), 8.2.1(Sizes) |
- |
2000 |
|
- |
| 7(FREEDOM FROM DEFECTS) |
- |
2000 |
|
- |
| 6.2(zinc Purity) |
- |
2000 |
|
- |
| 9(Joint in wires) |
- |
2000 |
|
- |
| 6.1.1(Aluminum wires shall conform to IS 5484) |
- |
2000 |
|
- |
| 6.1.2(The mechanical properties of wire
shall comply with the requirements given in Table 2) |
- |
1000 |
|
- |
| 6.2(It shall conform to and satisfy all the requirements
of IS 209) |
- |
1000 |
|
- |
| 8.2.2(Calculated resistance) |
- |
1000 |
|
- |
| Cl-9.2.5(Welded joint strength) |
- |
2000 |
|
- |
|
07 Sep, 2026 |
- - |
| 1905 |
BIS, Eastern Regional Laboratory (ERL)
| None
| IS 15905 (2024) |
Hubless Centrifugally Cast (Spun) Iron Pipes, Fittings and Accessories — Spigot Series —Specification |
For all sizes except for the tests mentioned in remarks |
- View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl-10.2 (External Diameters and Tolerances) |
- |
|
|
|
| Cl-10.3 (Thickness and Tolerances) |
- |
|
|
|
| Cl-10.5 (Tolerances on Angles) |
- |
|
|
|
| Cl-10.6 (Straightness of Pipe) |
- |
|
|
|
| 7 ("VISUAL INSPECTION AND HAMMER
TEST") |
- |
|
|
|
| 6 (JOINTS) |
- |
|
|
|
| 11 (COATING) |
- |
|
|
|
|
- |
- Mech: Except 8 (crushing Test), 9 (Hydrostatic Test), 11.2 (resistance to salt spray) |
| 1906 |
URS PRODUCTS AND TESTING PVT. LTD. (A29), NOIDA
| 8168906
| IS 302 : Part 2 : Sec 14 (2009) |
Safety of household and similar electrical appliances: Part 2 particular requirements: Sec 14 electric kitchen machines (First Revision) |
- |
65000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 6(Classification- IS 302-1 ) |
- |
500 |
|
Additional Testing Charge For EMI/EMC:- 20,0000/- |
| 6(Classification- IS 302-1) |
- |
0 |
|
- |
| 7.1(Marking- IS 302-1) |
- |
500 |
|
- |
| 7.1(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.1(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.1(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.1(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.1(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.1(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.1(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.3(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.4(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.6(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.7(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.8(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.11(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.12(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.13(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.14(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.15(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.101(Marking) |
- |
0 |
|
- |
| 8( Protection Against Electric Shock, IS 302-1) |
- |
5000 |
|
- |
| 10(Power Input and Current, IS 302-1) |
- |
5000 |
|
- |
| 11(Heating, IS 302-1) |
- |
10000 |
|
- |
| 11(Heating, IS 302-1) |
- |
0 |
|
- |
| 11(Heating, IS 302-1) |
- |
0 |
|
- |
| 11(Heating, IS 302-1) |
- |
0 |
|
- |
| 11(Heating, IS 302-1) |
- |
0 |
|
- |
| 13(Electrical Insulation and Leakage Current at Operating Temperature: Leakage current, IS 302-1) |
- |
2500 |
|
- |
| 13(Electrical Insulation and Leakage Current at Operating Temperature: High Voltage, IS 302-1) |
- |
2500 |
|
- |
| 14(Transient Over Voltages, IS 302-1) |
- |
5000 |
|
- |
| 15.1(Moisture Resistance, IS 302-1) |
- |
5000 |
|
- |
| 15.2(Moisture Resistance, IS 302-1) |
- |
5000 |
|
- |
| 15(Moisture Resistance, IS 302-1) |
- |
2500 |
|
- |
| 16(Electrical Insulation and Leakage Current at Operating Temperature: Leakage current, IS 302-1) |
- |
2500 |
|
- |
| 16(Electrical Insulation and Leakage Current at Operating Temperature: High Voltage, IS 302-1) |
- |
0 |
|
- |
| 17(Overload protection of Transformers and Associated Circuits, IS 302-1) |
- |
5000 |
|
- |
| 17(Overload protection of Transformers and Associated Circuits, IS 302-1) |
- |
0 |
|
- |
| 19.7(Abnormal Operation, IS 302-1) |
- |
5000 |
|
- |
| 19.8(Abnormal Operation, IS 302-1) |
- |
2500 |
|
- |
| 19.9(Abnormal Operation, IS 302-1) |
- |
2500 |
|
- |
| 19.1(Abnormal Operation, IS 302-1) |
- |
2500 |
|
- |
| 19.101(Abnormal Operation) |
- |
2500 |
|
- |
| 19.102(Abnormal Operation) |
- |
2500 |
|
- |
| 20.1(Stability & Mechanical Hazards, IS 302-1) |
- |
2500 |
|
- |
| 20.2(Stability & Mechanical Hazards, IS 302-1) |
- |
500 |
|
- |
| 20.101(Stability & Mechanical Hazards) |
- |
500 |
|
- |
| 20.102(Stability & Mechanical Hazards) |
- |
500 |
|
- |
| 20.103(Stability & Mechanical Hazards) |
- |
500 |
|
- |
| 20.104(Stability & Mechanical Hazards) |
- |
500 |
|
- |
| 20.105(Stability & Mechanical Hazards) |
- |
500 |
|
- |
| 20.106(Stability & Mechanical Hazards) |
- |
500 |
|
- |
| 20.107(Stability & Mechanical Hazards) |
- |
500 |
|
- |
| 20.108(Stability & Mechanical Hazards) |
- |
500 |
|
- |
| 20.109(Stability & Mechanical Hazards) |
- |
500 |
|
- |
| 20.110(Stability & Mechanical Hazards) |
- |
500 |
|
- |
| 20.111(Stability & Mechanical Hazards) |
- |
500 |
|
- |
| 20.112(Stability & Mechanical Hazards) |
- |
500 |
|
- |
| 20.113(Stability & Mechanical Hazards) |
- |
500 |
|
- |
| 20.114(Stability & Mechanical Hazards) |
- |
500 |
|
- |
| 20.115(Stability & Mechanical Hazards) |
- |
500 |
|
- |
| 20.116(Stability & Mechanical Hazards) |
- |
500 |
|
- |
| 21.1(Mechanical Strength, IS 302-1) |
- |
2500 |
|
- |
| 21.2(Mechanical Strength, IS 302-1) |
- |
2500 |
|
- |
| 22(Construction, IS 302-1) |
- |
5000 |
|
- |
| 22.101(Construction) |
- |
500 |
|
- |
| 22.102(Construction) |
- |
500 |
|
- |
| 23.1(Internal Wiring, IS 302-1) |
- |
5000 |
|
- |
| 23.2(Internal Wiring, IS 302-1) |
- |
0 |
|
- |
| 23.3(Internal Wiring, IS 302-1) |
- |
500 |
|
- |
| 23.4(Internal Wiring, IS 302-1) |
- |
500 |
|
- |
| 23.5(Internal Wiring, IS 302-1) |
- |
500 |
|
- |
| 23.6(Internal Wiring, IS 302-1) |
- |
500 |
|
- |
| 23.7(Internal Wiring, IS 302-1) |
- |
500 |
|
- |
| 23.8(Internal Wiring, IS 302-1) |
- |
500 |
|
- |
| 23.9(Internal Wiring, IS 302-1) |
- |
500 |
|
- |
| 23.10(Internal Wiring, IS 302-1) |
- |
500 |
|
- |
| 24.1(Components, IS 302-1) |
- |
500 |
|
- |
| 24.2(Components, IS 302-1) |
- |
500 |
|
- |
| 24.5(Components, IS 302-1) |
- |
500 |
|
- |
| 24.6(Components, IS 302-1) |
- |
500 |
|
- |
| 25.1(Supply Connection and External Flexible Cords, IS 302-1) |
- |
5000 |
|
- |
| 25.5(Supply Connection and External Flexible Cords, IS 302-1) |
- |
500 |
|
- |
| 25.6(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
- |
| 25.7(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
- |
| 25.8(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
- |
| 26.9(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
- |
| 25.1(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
- |
| 25.11(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
- |
| 25.12(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
- |
| 25.13(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
- |
| 25.14(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
- |
| 25.14(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
- |
| 25.15(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
- |
| 25.16(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
- |
| 25.17(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
- |
| 25.18(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
- |
| 25.19(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
- |
| 25.2(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
- |
| 25.21(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
- |
| 25.22(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
- |
| 26(Terminals for External Conductors, IS 302-1) |
- |
5000 |
|
- |
| 27(Provision for Earthing, IS 302-1) |
- |
5000 |
|
- |
| 27.2(Provision for Earthing, IS 302-1) |
- |
0 |
|
- |
| 27.3(Provision for Earthing, IS 302-1) |
- |
0 |
|
- |
| 27.4(Provision for Earthing, IS 302-1) |
- |
0 |
|
- |
| 27.5(Provision for Earthing, IS 302-1) |
- |
0 |
|
- |
| 28(Screws & Connections, IS 302-1) |
- |
5000 |
|
- |
| 29.1(Clearances, Creepage distances and Solid Insulation, IS 302-1) |
- |
5000 |
|
- |
| 29.2(Clearances, Creepage distances and Solid Insulation, IS 302-1) |
- |
0 |
|
- |
| 30.1(Resistance to Heat and Fire, IS 302-1) |
- |
5000 |
|
- |
| 30.2(Resistance to Heat and Fire, IS 302-1) |
- |
0 |
|
- |
| 31(Resistance of Rusting, IS 302-1) |
- |
2500 |
|
- |
| 32(Radiation, Toxicity and similar Hazard IS 302-1) |
- |
2500 |
|
- |
| 19.11.4.1(Electrostatic discharges) |
- |
25000 |
|
- |
| 19.11.4.2(Radiated fields) |
- |
45000 |
|
- |
| 19.11.4.3(Fast transient bursts) |
- |
25000 |
|
- |
| 19.11.4.4(Surge immunity test) |
- |
25000 |
|
- |
| 19.11.4.5(Immunity to conducted discharges) |
- |
30000 |
|
- |
| 19.11.4.6(Class 3 Voltage dips and interruptions) |
- |
25000 |
|
- |
| 19.11.4.7(Harmonics) |
- |
25000 |
|
- |
| 19.11.4.5(Immunity to conducted discharges) |
- |
0 |
|
- |
| 4(GENERAL REQUIREMENTS) |
- |
500 |
|
- |
| 5(GENERAL CONDITIONS FOR THE TESTS) |
- |
500 |
|
- |
| 27(Provision for Earthing) |
- |
500 |
|
- |
| 29(Clearances, Creepage distances and Solid Insulation) |
- |
500 |
|
- |
|
26 Sep, 2027 |
- Included w.e.f. 18.08.2025 |
| 1907 |
UL India Private limited, Gurgaon
| 8127226
| IS 302 : Part 1 (2024) |
Household and Similar Electrical Appliances â Safety Part 1 General Requirements (Seventh Revision) |
Household and Similar Electrical Appliances |
95000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 7(Marking and instructions) |
- |
1500 |
|
- |
| 8.1.1(Protection against live parts in all positions) |
- |
3000 |
|
Testing Charges of complete Cl. No. 8, IS 302-1:2024 |
| 8.1.2(Protection against live parts in openings) |
- |
0 |
|
Not Applicable (Testing charges as per complete Cl. 8) |
| 8.1.3(Protection against live parts in visible glowing heating elements) |
- |
0 |
|
Not Applicable (Testing charges as per complete Cl. 8) |
| 8.1.4(Protection against live parts against protective impedance) |
- |
0 |
|
Not Applicable (Testing charges as per complete Cl. 8) |
| 8.1.5(Live parts of built-in appliances) |
- |
0 |
|
Not Applicable (Testing charges as per complete Cl. 8) |
| 10.1(Power input) |
- |
8000 |
|
Testing Charges of complete Cl. No. 10, IS 302-1:2024 |
| 10.2(Current input) |
- |
0 |
|
Not Applicable (Testing charges as per complete Cl. 10) |
| 11.1(General) |
- |
10000 |
|
Testing Charges of complete Cl. No. 11, IS 302-1:2024 |
| 11.2(General) |
- |
0 |
|
Not Applicable (Testing charges as per complete Cl. 11) |
| 11.3(Heating) |
- |
0 |
|
Not Applicable (Testing charges as per complete Cl. 11) |
| 11.4(Heating appliances) |
- |
0 |
|
Not Applicable (Testing charges as per complete Cl. 11) |
| 11.5(Motor-operated appliances) |
- |
0 |
|
Not Applicable (Testing charges as per complete Cl. 11) |
| 11.6(Combined appliances) |
- |
0 |
|
Not Applicable (Testing charges as per complete Cl. 11) |
| 11.7(Duration corresponding) |
- |
0 |
|
Not Applicable (Testing charges as per complete Cl. 11) |
| 11.8(Temperature rise) |
- |
0 |
|
Not Applicable (Testing charges as per complete Cl. 11) |
| 12(Charging of metal-ion batteries) |
- |
2000 |
|
- |
| 13(Leakage current and electric strength at operating temperature) |
- |
5000 |
|
Testing Charges of complete Cl. No. 13, IS 302-1:2024 |
| 13.2(Leakage current at operating temperature) |
- |
0 |
|
Not Applicable (Testing charges as per complete Cl. 13) |
| 13.3(Electric Strength at operating temperature) |
- |
0 |
|
Not Applicable (Testing charges as per complete Cl. 13) |
| 14(Transient Over Voltages) |
- |
8000 |
|
- |
| 15.1(Ingress Protection test other than IPX0 (IP test)) |
- |
8000 |
|
Testing Charges of complete Cl. No. 15, IS 302-1:2024 |
| 15.3(Humidity Test) |
- |
0 |
|
Not Applicable (Testing charges as per complete Cl. 15) |
| 15.0(Moisture resistance) |
- |
0 |
|
Not Applicable (Testing charges as per complete Cl. 15) |
| 16(Leakage current and electric strength) |
- |
5000 |
|
Testing Charges of complete Cl. No. 16, IS 302-1:2024 |
| 17(Overload protection of transformers and associated circuits) |
- |
5000 |
|
Testing Charges of complete Cl. No. 17, IS 302-1:2024 |
| 19(Abnormal Operation) |
- |
8000 |
|
Testing Charges of complete Cl. No. 19, IS 302-1:2024 |
| 20.1(Stability & Mechanical Hazards, IS 302-1) |
- |
3000 |
|
Testing Charges of complete Cl. No. 20, IS 302-1:2024 |
| 21.1(Mechanical Strength, IS 302-1) |
- |
6000 |
|
Testing Charges of complete Cl. No. 21, IS 302-1:2024 |
| 22.1(Construction, IS 302-1) |
- |
6000 |
|
Testing Charges of complete Cl. No. 22, IS 302-1:2024 |
| 23.1(Internal Wiring, IS 302-1) |
- |
1000 |
|
Testing Charges of complete Cl. No. 23, IS 302-1:2024 |
| 25.8(Supply Connection and External Flexible Cords, IS 302-1) |
- |
1000 |
|
Testing Charges of complete Cl. No. 25, IS 302-1:2024 |
| 26(Terminals for external conductors) |
- |
1000 |
|
Testing Charges of complete Cl. No. 26, IS 302-1:2024 |
| 27.1(Provision for Earthing, IS 302-1) |
- |
1500 |
|
Testing Charges of complete Cl. No. 27, IS 302-1:2024 |
| 28(Screw test and connections) |
- |
1500 |
|
Testing Charges of complete Cl. No. 28, IS 302-1:2024 |
| 29(clearance, creepage distances and solid insulation) |
- |
2500 |
|
Testing Charges of complete Cl. No. 29, IS 302-1:2024 |
| 30.1(Ball pressure test) |
- |
6000 |
|
Testing Charges of complete Cl. No. 30, IS 302-1:2024 |
| 30.2(Glow Wire Test) |
- |
0 |
|
Not Applicable (Testing charges as per complete Cl. 30) |
| 30.2(Needle Flame Test) |
- |
0 |
|
Not Applicable (Testing charges as per complete Cl. 30) |
| 31(Resistance to Rusting) |
- |
2000 |
|
Testing Charges of complete Cl. No. 31, IS 302-1:2024 |
| 5(General conditions for the tests) |
- |
0 |
|
Not Applicable |
| 6(Classification- IS 302-1) |
- |
0 |
|
Not Applicable |
| 4(General requirement) |
- |
0 |
|
Not Applicable |
| 15.2(Spillage Test) |
- |
0 |
|
Not Applicable (Testing charges as per complete Cl. 15) |
| 16.0(General) |
- |
0 |
|
Not Applicable (Testing charges as per complete Cl. 16) |
| 16.1(General) |
- |
0 |
|
Not Applicable (Testing charges as per complete Cl. 16) |
| 16.2(Leakage Current (after Clause 15)) |
- |
0 |
|
Not Applicable (Testing charges as per complete Cl. 16) |
| 16.3(Electric Strength (after clause 15 and 16.2)) |
- |
0 |
|
Not Applicable (Testing charges as per complete Cl. 16) |
| 19.11.4.5(Immunity to conducted discharges) |
- |
0 |
|
Not Applicable (Testing charges as per complete Cl. 19) |
| 19.11.4.6(Class 3 Voltage dips and interruptions) |
- |
0 |
|
Not Applicable (Testing charges as per complete Cl. 19) |
| 19.11.4.7(Harmonics) |
- |
0 |
|
Not Applicable (Testing charges as per complete Cl. 19) |
| 19.17(Abnormal Operation, IS 302-1) |
- |
0 |
|
Not Applicable (Testing charges as per complete Cl. 19) |
| 20.2(Stability & Mechanical Hazards, IS 302-1) |
- |
0 |
|
Not Applicable (Testing charges as per complete Cl. 20) |
| 21.2(Mechanical Strength, IS 302-1) |
- |
0 |
|
Not Applicable (Testing charges as per complete Cl. 21) |
| 21.3(Mechanical Strength, IS 302-1) |
- |
0 |
|
Not Applicable (Testing charges as per complete Cl. 21) |
| 22.5(Construction) |
- |
0 |
|
Not Applicable (Testing charges as per complete Cl. 22) |
| 22.6(Construction, IS 302-1) |
- |
0 |
|
Not Applicable (Testing charges as per complete Cl. 22) |
| 22.11(Construction, IS 302-1) |
- |
0 |
|
Not Applicable (Testing charges as per complete Cl. 22) |
| 22.16(Construction) |
- |
0 |
|
Not Applicable (Testing charges as per complete Cl. 22) |
| 22.42(Construction) |
- |
0 |
|
Not Applicable (Testing charges as per complete Cl. 22) |
| 23.3(Internal Wiring, IS 302-1) |
- |
0 |
|
Not Applicable (Testing charges as per complete Cl. 23) |
| 25.7(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
Not Applicable (Testing charges as per complete Cl. 25) |
| 25.14(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
Not Applicable (Testing charges as per complete Cl. 25) |
| 25.15(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
Not Applicable (Testing charges as per complete Cl. 25) |
| 26.5(Terminals for external conductors) |
- |
0 |
|
Not Applicable (Testing charges as per complete Cl. 26) |
| 27.5(Provision for Earthing, IS 302-1) |
- |
0 |
|
Not Applicable (Testing charges as per complete Cl. 27) |
| 28.1(Screws and connections) |
- |
0 |
|
Not Applicable (Testing charges as per complete Cl. 28) |
| A.2(Earth continuity test) |
- |
0 |
|
Not Applicable (Testing charges as per complete Cl. 27) |
| 22.2(Construction, IS 302-1) |
- |
0 |
|
Not Applicable (Testing charges as per complete Cl. 12) |
| 22.3(Construction, IS 302-1) |
- |
0 |
|
Not Applicable (Testing charges as per complete Cl. 12) |
| B.22.4(Construction, IS 302-1) |
- |
0 |
|
Not Applicable (Testing charges as per complete Cl. 12) |
| B.22.5(Construction, IS 302-1) |
- |
0 |
|
Not Applicable (Testing charges as per complete Cl. 12) |
| Annex C(Ageing test on motors) |
- |
0 |
|
Not Applicable |
| Annex D(Thermal motor protectors) |
- |
0 |
|
Not Applicable |
| 25.6(Supply connection and external flexible cords, IS 302-1) |
- |
0 |
|
Not Applicable (Testing charges as per complete Cl. 25) |
| 17(Over Load Protection of Transformers and associated circuits) |
- |
0 |
|
Not Applicable (Testing charges as per complete Cl. 17) |
| 15.2(Moisture resistance) |
- |
0 |
|
Not Applicable (Testing charges as per complete Cl. 15) |
| 7(Marking and instructions) |
- |
0 |
|
Not Applicable (Testing charges as per complete Cl. 7) |
| 8.1.1(Protection against live parts in all positions) |
- |
0 |
|
Not Applicable (Testing charges as per complete Cl. 8) |
| 8.1.2(Protection against live parts in openings) |
- |
0 |
|
Not Applicable (Testing charges as per complete Cl. 8) |
| 8.1.3(Protection against live parts in visible glowing heating elements) |
- |
0 |
|
Not Applicable (Testing charges as per complete Cl. 8) |
| 8.1.4(Protection against live parts against protective impedance) |
- |
0 |
|
Not Applicable (Testing charges as per complete Cl. 8) |
| 8.1.5(Live parts of built-in appliances) |
- |
0 |
|
Not Applicable (Testing charges as per complete Cl. 8) |
| 10.1(Power input) |
- |
0 |
|
Not Applicable (Testing charges as per complete Cl. 10) |
| 10.2(Current input) |
- |
0 |
|
Not Applicable (Testing charges as per complete Cl. 10) |
| 11.1(General) |
- |
0 |
|
Not Applicable (Testing charges as per complete Cl. 11) |
| 11.2(General) |
- |
0 |
|
Not Applicable (Testing charges as per complete Cl. 11) |
| 11.3(Heating) |
- |
0 |
|
Not Applicable (Testing charges as per complete Cl. 11) |
| 11.4(Heating appliances) |
- |
0 |
|
Not Applicable (Testing charges as per complete Cl. 11) |
| 11.5(Motor-operated appliances) |
- |
0 |
|
Not Applicable (Testing charges as per complete Cl. 11) |
| 11.6(Combined appliances) |
- |
0 |
|
Not Applicable (Testing charges as per complete Cl. 11) |
| 11.7(Duration corresponding) |
- |
0 |
|
Not Applicable (Testing charges as per complete Cl. 11) |
| 11.8(Temperature rise) |
- |
0 |
|
Not Applicable (Testing charges as per complete Cl. 11) |
| 12(Charging of metal-ion batteries) |
- |
0 |
|
Not Applicable (Testing charges as per complete Cl. 12) |
| 13(Leakage current and electric strength at operating temperature) |
- |
0 |
|
Not Applicable (Testing charges as per complete Cl. 13) |
| 13.2(Leakage current at operating temperature) |
- |
0 |
|
Not Applicable (Testing charges as per complete Cl. 13) |
| 13.3(Electric Strength at operating temperature) |
- |
0 |
|
Not Applicable (Testing charges as per complete Cl. 13) |
| 14(Transient Over Voltages) |
- |
0 |
|
Not Applicable (Testing charges as per complete Cl. 14) |
| 15.1(Ingress Protection test other than IPX0 (IP test)) |
- |
0 |
|
Not Applicable (Testing charges as per complete Cl. 15) |
| 15.3(Humidity Test) |
- |
0 |
|
Not Applicable (Testing charges as per complete Cl. 15) |
| 15.0(Moisture resistance) |
- |
0 |
|
Not Applicable (Testing charges as per complete Cl. 15) |
| 16(Leakage current and electric strength) |
- |
0 |
|
Not Applicable (Testing charges as per complete Cl. 16) |
| 17(Overload protection of transformers and associated circuits) |
- |
0 |
|
Not Applicable (Testing charges as per complete Cl. 17) |
| 19(Abnormal Operation) |
- |
0 |
|
Not Applicable (Testing charges as per complete Cl. 19) |
| 20.1(Stability & Mechanical Hazards, IS 302-1) |
- |
0 |
|
Not Applicable (Testing charges as per complete Cl. 20) |
| 21.1(Mechanical Strength, IS 302-1) |
- |
0 |
|
Not Applicable (Testing charges as per complete Cl. 21) |
| 22.1(Construction, IS 302-1) |
- |
0 |
|
Not Applicable (Testing charges as per complete Cl. 22) |
| 23.1(Internal Wiring, IS 302-1) |
- |
0 |
|
Not Applicable (Testing charges as per complete Cl. 23) |
| 25.8(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
Not Applicable (Testing charges as per complete Cl. 25) |
| 26(Terminals for external conductors) |
- |
0 |
|
Not Applicable (Testing charges as per complete Cl. 26) |
| 27.1(Provision for Earthing, IS 302-1) |
- |
0 |
|
Not Applicable (Testing charges as per complete Cl. 27) |
| 28(Screw test and connections) |
- |
0 |
|
Not Applicable (Testing charges as per complete Cl. 28) |
| 29(clearance, creepage distances and solid insulation) |
- |
0 |
|
Not Applicable (Testing charges as per complete Cl. 29) |
| 30.1(Ball pressure test) |
- |
0 |
|
Not Applicable (Testing charges as per complete Cl. 30) |
| 30.2(Glow Wire Test) |
- |
0 |
|
Not Applicable (Testing charges as per complete Cl. 30) |
| 30.2(Needle Flame Test) |
- |
0 |
|
Not Applicable (Testing charges as per complete Cl. 30) |
| 31(Resistance to Rusting) |
- |
0 |
|
Not Applicable (Testing charges as per complete Cl. 31) |
| 5(General conditions for the tests) |
- |
0 |
|
Not Applicable |
| 6(Classification- IS 302-1) |
- |
0 |
|
Not Applicable |
| 4(General requirement) |
- |
0 |
|
Not Applicable |
| 15.2(Spillage Test) |
- |
0 |
|
Not Applicable (Testing charges as per complete Cl. 15) |
| 16.0(General) |
- |
0 |
|
Not Applicable (Testing charges as per complete Cl. 16) |
| 16.1(General) |
- |
0 |
|
Not Applicable (Testing charges as per complete Cl. 16) |
| 16.2(Leakage Current (after Clause 15)) |
- |
0 |
|
Not Applicable (Testing charges as per complete Cl. 16) |
| 16.3(Electric Strength (after clause 15 and 16.2)) |
- |
0 |
|
Not Applicable (Testing charges as per complete Cl. 16) |
| 19.11.4.5(Immunity to conducted discharges) |
- |
0 |
|
Not Applicable (Testing charges as per complete Cl. 19) |
| 19.11.4.6(Class 3 Voltage dips and interruptions) |
- |
0 |
|
Not Applicable (Testing charges as per complete Cl. 19) |
| 19.11.4.7(Harmonics) |
- |
0 |
|
Not Applicable (Testing charges as per complete Cl. 19) |
| 19.17(Abnormal Operation, IS 302-1) |
- |
0 |
|
Not Applicable (Testing charges as per complete Cl. 19) |
| 20.2(Stability & Mechanical Hazards, IS 302-1) |
- |
0 |
|
Not Applicable (Testing charges as per complete Cl. 20) |
| 21.2(Mechanical Strength, IS 302-1) |
- |
0 |
|
Not Applicable (Testing charges as per complete Cl. 21) |
| 21.3(Mechanical Strength, IS 302-1) |
- |
0 |
|
Not Applicable (Testing charges as per complete Cl. 21) |
| 22.5(Construction) |
- |
0 |
|
Not Applicable (Testing charges as per complete Cl. 22) |
| 22.6(Construction, IS 302-1) |
- |
0 |
|
Not Applicable (Testing charges as per complete Cl. 22) |
| 22.11(Construction, IS 302-1) |
- |
0 |
|
Not Applicable (Testing charges as per complete Cl. 22) |
| 22.16(Construction) |
- |
0 |
|
Not Applicable (Testing charges as per complete Cl. 22) |
| 22.42(Construction) |
- |
0 |
|
Not Applicable (Testing charges as per complete Cl. 22) |
| 23.3(Internal Wiring, IS 302-1) |
- |
0 |
|
Not Applicable (Testing charges as per complete Cl. 23) |
| 25.7(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
Not Applicable (Testing charges as per complete Cl. 25) |
| 25.14(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
Not Applicable (Testing charges as per complete Cl. 25) |
| 25.15(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
Not Applicable (Testing charges as per complete Cl. 25) |
| 26.5(Terminals for external conductors) |
- |
0 |
|
Not Applicable (Testing charges as per complete Cl. 26) |
| 27.5(Provision for Earthing, IS 302-1) |
- |
0 |
|
Not Applicable (Testing charges as per complete Cl. 27) |
| 28.1(Screws and connections) |
- |
0 |
|
Not Applicable (Testing charges as per complete Cl. 28) |
| A.2(Earth continuity test) |
- |
0 |
|
Not Applicable (Testing charges as per complete Cl. 27) |
| 22.2(Construction, IS 302-1) |
- |
0 |
|
Not Applicable (Testing charges as per complete Cl. 12) |
| 22.3(Construction, IS 302-1) |
- |
0 |
|
Not Applicable (Testing charges as per complete Cl. 12) |
| B.22.4(Construction, IS 302-1) |
- |
0 |
|
Not Applicable (Testing charges as per complete Cl. 12) |
| B.22.5(Construction, IS 302-1) |
- |
0 |
|
Not Applicable (Testing charges as per complete Cl. 12) |
| Annex C(Ageing test on motors) |
- |
0 |
|
Not Applicable (Testing charges as per complete Cl. 11) |
| Annex D(Thermal motor protectors) |
- |
0 |
|
Not Applicable (Testing charges as per complete Cl. 11) |
| 25.6(Supply connection and external flexible cords, IS 302-1) |
- |
0 |
|
Not Applicable (Testing charges as per complete Cl. 25) |
| 17(Over Load Protection of Transformers and associated circuits) |
- |
0 |
|
Not Applicable Not Applicable (Testing charges as per complete Cl. 17) |
| 15.2(Moisture resistance) |
- |
0 |
|
Not Applicable Not Applicable (Testing charges as per complete Cl. 15) |
|
07 Aug, 2028 |
view Scope file Included w.e.f.21.08.2025
Exclusion
Cl 19.11.4.1 to Cl 19.11.4.7 EMI/EMC
"Domestic Electric Clothes Washing Machines
(For testing charges please refer part 2 standard in LIMS)" |
| 1908 |
RTRC LIMITED, GURUGRAM
| 9177406
| IS 12444 (2020) |
Copper Wire Rods for Electrical Applications — Specification ( First Revision ) |
Copper Wire Rods for Electrical Applications — Specification |
20000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 5.1 Table-1(Te) |
- |
1000 |
|
- |
| 5.1 Table-1(Se) |
- |
1000 |
|
- |
| 5.1 Table-1(Bi) |
- |
1000 |
|
- |
| 5.1 Table-1(Se+Te+Bi) |
- |
0 |
|
- |
| 5.1 Table-1(Sb) |
- |
1000 |
|
- |
| 5.1 Table-1(As) |
- |
1000 |
|
- |
| 5.1 Table-1(Sn) |
- |
1000 |
|
- |
| 5.1 Table-1(Pb) |
- |
1000 |
|
- |
| 5.1 Table-1(Fe) |
- |
1000 |
|
- |
| 5.1 Table-1(Ni) |
- |
1000 |
|
- |
| 5.1 Table-1(S) |
- |
1000 |
|
- |
| 5.1 Table-1(Ag) |
- |
1000 |
|
- |
| 5.1 Table-1(O) |
- |
1000 |
|
- |
| 5.1 Table-1(Maximum Allowable Total Impurities) |
- |
500 |
|
- |
| 6.1(Dimension) |
- |
0 |
|
- |
| 6.2.2(Ovality) |
- |
0 |
|
- |
| 7.0(Freedom from Defects) |
- |
0 |
|
- |
| 8.1(Tensile Strength) |
- |
2500 |
|
- |
| 8.2(Surface Compression Test) |
- |
1000 |
|
- |
| Cl-9.1, Table-4(Volume Resistivity) |
- |
2500 |
|
- |
| Cl-9.1, Table-4(Mass Resistivity) |
- |
0 |
|
- |
| Cl-9.1, Table-4(Electrical Conductivity) |
- |
0 |
|
- |
| 10.5(Microscopic Examination) |
- |
0 |
|
- |
| 9.2.1.1(Electrical Properties) |
- |
0 |
|
- |
| 9.2.1.2(Electrical Properties) |
- |
0 |
|
- |
| 9.2.1.3(Electrical Properties) |
- |
0 |
|
- |
| 13(Mechanical Strength) |
- |
0 |
|
- |
| 8.2.2(Calculated resistance) |
- |
0 |
|
- |
| Cl-9.2.2(Electrical Properties) |
- |
0 |
|
- |
| 7.2(Surface Oxide) |
- |
1500 |
|
- |
| Cl-9.1, Table-4(Volume Resistivity) |
- |
0 |
|
- |
| Cl-9.1, Table-4(Mass Resistivity) |
- |
0 |
|
- |
| Cl-9.1, Table-4(Electrical Conductivity) |
- |
0 |
|
- |
| 10.5(Microscopic Examination) |
- |
0 |
|
- |
| 9.2.1.1(Electrical Properties) |
- |
0 |
|
- |
| 9.2.1.2(Electrical Properties) |
- |
0 |
|
- |
| 9.2.1.3(Electrical Properties) |
- |
0 |
|
- |
| 13(Mechanical Strength) |
- |
0 |
|
- |
| 8.2.2(Calculated resistance) |
- |
0 |
|
- |
| Cl-9.2.2(Electrical Properties) |
- |
0 |
|
- |
| 7.2(Surface Oxide) |
- |
0 |
|
- |
| Cl-9.1, Table-4(Volume Resistivity) |
- |
0 |
|
- |
| Cl-9.1, Table-4(Mass Resistivity) |
- |
0 |
|
- |
| Cl-9.1, Table-4(Electrical Conductivity) |
- |
0 |
|
- |
| 10.5(Microscopic Examination) |
- |
0 |
|
- |
| 9.2.1.1(Electrical Properties) |
- |
0 |
|
- |
| 9.2.1.2(Electrical Properties) |
- |
0 |
|
- |
| 9.2.1.3(Electrical Properties) |
- |
0 |
|
- |
| 13(Mechanical Strength) |
- |
0 |
|
- |
| 8.2.2(Calculated resistance) |
- |
0 |
|
- |
| Cl-9.2.2(Electrical Properties) |
- |
0 |
|
- |
| 7.2(Surface Oxide) |
- |
0 |
|
- |
| Cl-9.1, Table-4(Volume Resistivity) |
- |
0 |
|
- |
| Cl-9.1, Table-4(Mass Resistivity) |
- |
0 |
|
- |
| Cl-9.1, Table-4(Electrical Conductivity) |
- |
0 |
|
- |
| 10.5(Microscopic Examination) |
- |
0 |
|
- |
| 9.2.1.1(Electrical Properties) |
- |
0 |
|
- |
| 9.2.1.2(Electrical Properties) |
- |
0 |
|
- |
| 9.2.1.3(Electrical Properties) |
- |
0 |
|
- |
| 13(Mechanical Strength) |
- |
0 |
|
- |
| 8.2.2(Calculated resistance) |
- |
0 |
|
- |
| Cl-9.2.2(Electrical Properties) |
- |
0 |
|
- |
| 7.2(Surface Oxide) |
- |
0 |
|
- |
| Cl-9.1, Table-4(Volume Resistivity) |
- |
0 |
|
- |
| Cl-9.1, Table-4(Mass Resistivity) |
- |
0 |
|
- |
| Cl-9.1, Table-4(Electrical Conductivity) |
- |
0 |
|
- |
| 10.5(Microscopic Examination) |
- |
0 |
|
- |
| 9.2.1.1(Electrical Properties) |
- |
0 |
|
- |
| 9.2.1.2(Electrical Properties) |
- |
0 |
|
- |
| 9.2.1.3(Electrical Properties) |
- |
0 |
|
- |
| 13(Mechanical Strength) |
- |
0 |
|
- |
| 8.2.2(Calculated resistance) |
- |
0 |
|
- |
| Cl-9.2.2(Electrical Properties) |
- |
0 |
|
- |
| 7.2(Surface Oxide) |
- |
0 |
|
- |
| Cl-9.1, Table-4(Volume Resistivity) |
- |
0 |
|
- |
| Cl-9.1, Table-4(Mass Resistivity) |
- |
0 |
|
- |
| Cl-9.1, Table-4(Electrical Conductivity) |
- |
0 |
|
- |
| 10.5(Microscopic Examination) |
- |
0 |
|
- |
| 9.2.1.1(Electrical Properties) |
- |
0 |
|
- |
| 9.2.1.2(Electrical Properties) |
- |
0 |
|
- |
| 9.2.1.3(Electrical Properties) |
- |
0 |
|
- |
| 13(Mechanical Strength) |
- |
0 |
|
- |
| 8.2.2(Calculated resistance) |
- |
0 |
|
- |
| Cl-9.2.2(Electrical Properties) |
- |
0 |
|
- |
| 7.2(Surface Oxide) |
- |
0 |
|
- |
| Cl-9.1, Table-4(Volume Resistivity) |
- |
0 |
|
- |
| Cl-9.1, Table-4(Mass Resistivity) |
- |
0 |
|
- |
| Cl-9.1, Table-4(Electrical Conductivity) |
- |
0 |
|
- |
| 10.5(Microscopic Examination) |
- |
0 |
|
- |
| 9.2.1.1(Electrical Properties) |
- |
0 |
|
- |
| 9.2.1.2(Electrical Properties) |
- |
0 |
|
- |
| 9.2.1.3(Electrical Properties) |
- |
0 |
|
- |
| 13(Mechanical Strength) |
- |
0 |
|
- |
| 8.2.2(Calculated resistance) |
- |
0 |
|
- |
| Cl-9.2.2(Electrical Properties) |
- |
0 |
|
- |
| 7.2(Surface Oxide) |
- |
0 |
|
- |
| Cl-9.1, Table-4(Volume Resistivity) |
- |
0 |
|
- |
| Cl-9.1, Table-4(Mass Resistivity) |
- |
0 |
|
- |
| Cl-9.1, Table-4(Electrical Conductivity) |
- |
0 |
|
- |
| 10.5(Microscopic Examination) |
- |
0 |
|
- |
| 9.2.1.1(Electrical Properties) |
- |
0 |
|
- |
| 9.2.1.2(Electrical Properties) |
- |
0 |
|
- |
| 9.2.1.3(Electrical Properties) |
- |
0 |
|
- |
| 13(Mechanical Strength) |
- |
0 |
|
- |
| 8.2.2(Calculated resistance) |
- |
0 |
|
- |
| Cl-9.2.2(Electrical Properties) |
- |
0 |
|
- |
| 7.2(Surface Oxide) |
- |
0 |
|
- |
| Cl-9.1, Table-4(Volume Resistivity) |
- |
0 |
|
- |
| Cl-9.1, Table-4(Mass Resistivity) |
- |
0 |
|
- |
| Cl-9.1, Table-4(Electrical Conductivity) |
- |
0 |
|
- |
| 10.5(Microscopic Examination) |
- |
0 |
|
- |
| 9.2.1.1(Electrical Properties) |
- |
0 |
|
- |
| 9.2.1.2(Electrical Properties) |
- |
0 |
|
- |
| 9.2.1.3(Electrical Properties) |
- |
0 |
|
- |
| 13(Mechanical Strength) |
- |
0 |
|
- |
| 8.2.2(Calculated resistance) |
- |
0 |
|
- |
| Cl-9.2.2(Electrical Properties) |
- |
0 |
|
- |
| 7.2(Surface Oxide) |
- |
0 |
|
- |
| Cl-9.1, Table-4(Volume Resistivity) |
- |
0 |
|
- |
| Cl-9.1, Table-4(Mass Resistivity) |
- |
0 |
|
- |
| Cl-9.1, Table-4(Electrical Conductivity) |
- |
0 |
|
- |
| 10.5(Microscopic Examination) |
- |
0 |
|
- |
| 9.2.1.1(Electrical Properties) |
- |
0 |
|
- |
| 9.2.1.2(Electrical Properties) |
- |
0 |
|
- |
| 9.2.1.3(Electrical Properties) |
- |
0 |
|
- |
| 13(Mechanical Strength) |
- |
0 |
|
- |
| 8.2.2(Calculated resistance) |
- |
0 |
|
- |
| Cl-9.2.2(Electrical Properties) |
- |
0 |
|
- |
| 7.2(Surface Oxide) |
- |
0 |
|
- |
| Cl-9.1, Table-4(Volume Resistivity) |
- |
0 |
|
- |
| Cl-9.1, Table-4(Mass Resistivity) |
- |
0 |
|
- |
| Cl-9.1, Table-4(Electrical Conductivity) |
- |
0 |
|
- |
| 10.5(Microscopic Examination) |
- |
0 |
|
- |
| 9.2.1.1(Electrical Properties) |
- |
0 |
|
- |
| 9.2.1.2(Electrical Properties) |
- |
0 |
|
- |
| 9.2.1.3(Electrical Properties) |
- |
0 |
|
- |
| 13(Mechanical Strength) |
- |
0 |
|
- |
| 8.2.2(Calculated resistance) |
- |
0 |
|
- |
| Cl-9.2.2(Electrical Properties) |
- |
0 |
|
- |
| 7.2(Surface Oxide) |
- |
0 |
|
- |
| Cl-9.1, Table-4(Volume Resistivity) |
- |
0 |
|
- |
| Cl-9.1, Table-4(Mass Resistivity) |
- |
0 |
|
- |
| Cl-9.1, Table-4(Electrical Conductivity) |
- |
0 |
|
- |
| 10.5(Microscopic Examination) |
- |
0 |
|
- |
| 9.2.1.1(Electrical Properties) |
- |
0 |
|
- |
| 9.2.1.2(Electrical Properties) |
- |
0 |
|
- |
| 9.2.1.3(Electrical Properties) |
- |
0 |
|
- |
| 13(Mechanical Strength) |
- |
0 |
|
- |
| 8.2.2(Calculated resistance) |
- |
0 |
|
- |
| Cl-9.2.2(Electrical Properties) |
- |
0 |
|
- |
| 7.2(Surface Oxide) |
- |
0 |
|
- |
| Cl-9.1, Table-4(Volume Resistivity) |
- |
0 |
|
- |
| Cl-9.1, Table-4(Mass Resistivity) |
- |
0 |
|
- |
| Cl-9.1, Table-4(Electrical Conductivity) |
- |
0 |
|
- |
| 10.5(Microscopic Examination) |
- |
0 |
|
- |
| 9.2.1.1(Electrical Properties) |
- |
0 |
|
- |
| 9.2.1.2(Electrical Properties) |
- |
0 |
|
- |
| 9.2.1.3(Electrical Properties) |
- |
0 |
|
- |
| 13(Mechanical Strength) |
- |
0 |
|
- |
| 8.2.2(Calculated resistance) |
- |
0 |
|
- |
| Cl-9.2.2(Electrical Properties) |
- |
0 |
|
- |
| 7.2(Surface Oxide) |
- |
0 |
|
- |
| Cl-9.1, Table-4(Volume Resistivity) |
- |
0 |
|
- |
| Cl-9.1, Table-4(Mass Resistivity) |
- |
0 |
|
- |
| Cl-9.1, Table-4(Electrical Conductivity) |
- |
0 |
|
- |
| 10.5(Microscopic Examination) |
- |
0 |
|
- |
| 9.2.1.1(Electrical Properties) |
- |
0 |
|
- |
| 9.2.1.2(Electrical Properties) |
- |
0 |
|
- |
| 9.2.1.3(Electrical Properties) |
- |
0 |
|
- |
| 13(Mechanical Strength) |
- |
0 |
|
- |
| 8.2.2(Calculated resistance) |
- |
0 |
|
- |
| Cl-9.2.2(Electrical Properties) |
- |
0 |
|
- |
| 7.2(Surface Oxide) |
- |
0 |
|
- |
| Cl-9.1, Table-4(Volume Resistivity) |
- |
0 |
|
- |
| Cl-9.1, Table-4(Mass Resistivity) |
- |
0 |
|
- |
| Cl-9.1, Table-4(Electrical Conductivity) |
- |
0 |
|
- |
| 10.5(Microscopic Examination) |
- |
0 |
|
- |
| 9.2.1.1(Electrical Properties) |
- |
0 |
|
- |
| 9.2.1.2(Electrical Properties) |
- |
0 |
|
- |
| 9.2.1.3(Electrical Properties) |
- |
0 |
|
- |
| 13(Mechanical Strength) |
- |
0 |
|
- |
| 8.2.2(Calculated resistance) |
- |
0 |
|
- |
| Cl-9.2.2(Electrical Properties) |
- |
0 |
|
- |
| 7.2(Surface Oxide) |
- |
0 |
|
- |
|
03 Apr, 2027 |
- Included w.e.f 16.09.2025 |
| 1909 |
Sleen India Biz venture Private Limited, Agra
| 9139736
| IS 3980 (1982) |
Specification for porous metal powder oil - Impregnated bearings (First Revision) |
- |
10250 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 2(Types ) |
- |
500 |
|
- |
| 3(Material ) |
- |
2500 |
|
- |
| 4.2(Dimensions and Tolerances) |
- |
1000 |
|
- |
| 5(Manufacture, Workmanship and Finish) |
- |
1000 |
|
- |
| 6(Designation ) |
- |
250 |
|
- |
| 7.1(Density ) |
- |
1000 |
|
- |
| 7.2(Porosity ) |
- |
1500 |
|
- |
| 7.3(Radial Crushing Strength ) |
- |
2250 |
|
- |
| 10(Marking) |
- |
250 |
|
- |
|
15 May, 2027 |
- Included w.e.f.26.08.2025 |
| 1910 |
TUV SUD SOUTH ASIA PRIVATE LIMITED RANIPET
| 6191806
| IS 6719 (1972) |
Solid Pvc Soles And Heels |
- |
4900 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl. 3.1,3.2,3.3,3.4,3.5(Material) |
- |
500 |
|
- |
| Cl. 3.1,3.2,3.3,3.4,3.5(Material) |
- |
500 |
|
- |
| 3.6 (i)(Relative density ) |
- |
400 |
|
- |
| 3.6.1(Hardness ) |
- |
400 |
|
- |
| Table 1 (Flexing resistance)(Table 1 (Flexing resistance, Bennewart method, cut growth at the end of 30 000 cycles, mm, Max)) |
- |
1200 |
|
- |
| Table 1 (Abrasion resistance)(Abrasion resistance at applied
force of 10 N (volume loss),
mm3, Max) |
- |
960 |
|
- |
| 3.6 (iv)(Tear Strength a) Force Part b) Back Part ) |
- |
480 |
|
- |
| 3.6 (iii)(Elongation at break, percent ) |
- |
480 |
|
- |
| 3.6 (ii)(Tensile Strength ) |
- |
480 |
|
- |
| 6 ,6.1,6.2,6.3(Test Method) |
- |
500 |
|
- |
| Cl. 6.4(Measurement of thickness) |
- |
400 |
|
- |
| Table 1 Cl. 3.6, Sl No (iv)("Lead (as Pb), Shoes for
infants, children and
boys and girls, ppm") |
- |
1200 |
|
- |
| Table 1 Cl. 3.6, Sl No (iv)("Lead (as Pb), for other sized shoes, ppm
") |
- |
1200 |
|
- |
| Table 1 Cl. 3.6, Sl No (iii)(Volatility, Percent by mass) |
- |
1200 |
|
- |
|
02 Dec, 2028 |
- - |
| 1911 |
Classic Testing & Research Centre (B17), Noida
| 8180826
| IS 17550 : Part 1 (2024) |
Household Refrigerating Appliances - Characteristics and Test Methods Part 1 General Requirements (First Revision) |
- |
205000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 5(MARKING) |
- |
15000 |
|
- |
| 8(MATERIALS, DESIGN, AND MANUFACTURE) |
- |
15000 |
|
- |
| 9(Testing The Air Tightness Of Door Or Lid Seal(S)) |
- |
15000 |
|
- |
| 10(Testing The Opening Force Of Door(S) Or Lid(S)) |
- |
15000 |
|
- |
| 11(Testing The Durability Of Hinges And Handles Of Door(S) And Lid(S) |
- |
15000 |
|
- |
| 12(Testing The Mechanical Strength Of Shelves And Similar Components) |
- |
15000 |
|
- |
| 14(Ice-Making Test (If Applicable)) |
- |
15000 |
|
- |
| 15(Test For Absence Of Odour And Taste) |
- |
20000 |
|
- |
| 16(Safety Requirements) |
- |
20000 |
|
- |
|
15 Oct, 2027 |
- Included w.e.f 19.12.2025 |
| 1912 |
SHRI KRISHNA TEST HOUSE PVT LTD (142)
| 8185606
| IS 191 (2007) |
Copper - Specification (Fourth Revision) |
ALL |
5000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4-Table 1(GRADES/DESIGNATIONS) |
- |
5000 |
|
- |
| 5.1- Table 2(L) |
- |
5000 |
|
- |
| 5.1- Table 2(L1) |
- |
5000 |
|
- |
| 5.1- Table 2(h) |
- |
5000 |
|
- |
| 5.1- Table 2(h1) |
- |
5000 |
|
- |
| 5.1- Table 2(b) |
- |
5000 |
|
- |
| 5.1- Table 2(b1) |
- |
5000 |
|
- |
| 5.1- Table 2(R) |
- |
5000 |
|
- |
| 5.1- Table 2(R1) |
- |
5000 |
|
- |
| 5.1- Table 2(R2 ) |
- |
5000 |
|
- |
| 5.1- Table 2(α ) |
- |
5000 |
|
- |
| 5.1- Table 2( β ) |
- |
5000 |
|
- |
| 5.1- Table 2(γ) |
- |
5000 |
|
- |
| 5.2(Billets) |
- |
5000 |
|
- |
| 5.4-Table 3 (For Billets)(Mass) |
- |
5000 |
|
- |
| 5.2-Table 3 (For Billets)(Diameter) |
- |
5000 |
|
- |
| 5.2-Table 3 (For Billets)(Length) |
- |
5000 |
|
- |
| 5.2-Table 3 (For Billets)(Deviation from straightness per 1000 mm length) |
- |
5000 |
|
- |
| 5.4-Table 3 (Vertically continuously cast wire bars)(Mass) |
- |
5000 |
|
- |
| 5.3-Table 3 (Vertically continuously cast wire bars)(Width) |
- |
5000 |
|
- |
| 5.3-Table 3 (Vertically continuously cast wire bars)(thickness ) |
- |
5000 |
|
- |
| 5.3-Table 3 (Vertically continuously cast wire bars)(Other dimention) |
- |
5000 |
|
- |
| 5.4-Table 3 (Vertically static cast wire bars)(Mass) |
- |
5000 |
|
- |
| 5.3-Table 3 (Vertically static cast wire bars)(Width) |
- |
5000 |
|
- |
| 5.3-Table 3 (Vertically static cast wire bars)(thickness ) |
- |
5000 |
|
- |
| 5.3-Table 3 (Vertically static cast wire bars)(Other dimention) |
- |
5000 |
|
- |
| 5.4-Table 3 (Ingots)(Mass) |
- |
5000 |
|
- |
| 5.4-Table 3 (Cast cakes)(Mass) |
- |
5000 |
|
- |
| 5.3-Table 3 (Cast cakes)(Width) |
- |
5000 |
|
- |
| 5.3-Table 3 (Cast cakes)(thickness ) |
- |
5000 |
|
- |
| 5.3-Table 3 (Cast cakes)(Deviation from straightness per 1000 mm length) |
- |
5000 |
|
- |
| 7.1 - Table 4(Copper + Silver(By difference)-IS440) |
- |
5000 |
|
- |
| 7.1 - Table 4(Silver- IS 440) |
- |
5000 |
|
- |
| 7.1 - Table 4(Copper (any Silver present to be counted as copper)-IS440) |
- |
5000 |
|
- |
| 7.1 - Table 4(Phosphorus- IS 440) |
- |
5000 |
|
- |
| 7.1 - Table 4(Arsenic- IS440) |
- |
5000 |
|
- |
| 7.1 - Table 4(Antimony-IS440) |
- |
5000 |
|
- |
| 7.1 - Table 4(Bismuth-IS 440) |
- |
5000 |
|
- |
| 7.1 - Table 4(Iron IS 440) |
- |
5000 |
|
- |
| 7.1 - Table 4(Lead IS 440) |
- |
5000 |
|
- |
| 7.1 - Table 4(Nickel IS 440) |
- |
5000 |
|
- |
| 7.1 - Table 4(Oxygen IS 440) |
- |
5000 |
|
- |
| 7.1 - Table 4(Selenium - IS 440) |
- |
5000 |
|
- |
| 7.1 - Table 4(Sulphur- IS 440) |
- |
5000 |
|
- |
| 7.1 - Table 4(Tellurium- IS 440) |
- |
5000 |
|
- |
| 7.1 - Table 4(Tin - IS 440) |
- |
5000 |
|
- |
| 7.1 - Table 4(Znic-IS 440) |
- |
5000 |
|
- |
| 7.1 - Table 4(Selenium + Telluuium- IS 440) |
- |
5000 |
|
- |
| 7.1 - Table 4(Total Impurities- IS 440) |
- |
5000 |
|
- |
| 8.1(FREEDOM FROM DEFECTS) |
- |
5000 |
|
- |
| 8.2(FREEDOM FROM DEFECTS) |
- |
5000 |
|
- |
| 9.1- Table 5(Mass Resistivity- IS 3635) |
- |
5000 |
|
- |
| 10(HYDROGEN EMBRITTLEMENT TEST- IS 191) |
- |
5000 |
|
- |
| 4-Table 1(GRADES/DESIGNATIONS) |
- |
5000 |
|
- |
| 5.1- Table 2(L) |
- |
5000 |
|
- |
| 5.1- Table 2(L1) |
- |
5000 |
|
- |
| 5.1- Table 2(h) |
- |
5000 |
|
- |
| 5.1- Table 2(h1) |
- |
5000 |
|
- |
| 5.1- Table 2(b) |
- |
5000 |
|
- |
| 5.1- Table 2(b1) |
- |
5000 |
|
- |
| 5.1- Table 2(R) |
- |
5000 |
|
- |
| 5.1- Table 2(R1) |
- |
5000 |
|
- |
| 5.1- Table 2(R2 ) |
- |
5000 |
|
- |
| 5.1- Table 2(α ) |
- |
5000 |
|
- |
| 5.1- Table 2( β ) |
- |
5000 |
|
- |
| 5.1- Table 2(γ) |
- |
5000 |
|
- |
| 5.2(Billets) |
- |
5000 |
|
- |
| 5.4-Table 3 (For Billets)(Mass) |
- |
5000 |
|
- |
| 5.2-Table 3 (For Billets)(Diameter) |
- |
5000 |
|
- |
| 5.2-Table 3 (For Billets)(Length) |
- |
5000 |
|
- |
| 5.2-Table 3 (For Billets)(Deviation from straightness per 1000 mm length) |
- |
5000 |
|
- |
| 5.4-Table 3 (Vertically continuously cast wire bars)(Mass) |
- |
5000 |
|
- |
| 5.3-Table 3 (Vertically continuously cast wire bars)(Width) |
- |
5000 |
|
- |
| 5.3-Table 3 (Vertically continuously cast wire bars)(thickness ) |
- |
5000 |
|
- |
| 5.3-Table 3 (Vertically continuously cast wire bars)(Other dimention) |
- |
5000 |
|
- |
| 5.4-Table 3 (Vertically static cast wire bars)(Mass) |
- |
5000 |
|
- |
| 5.3-Table 3 (Vertically static cast wire bars)(Width) |
- |
5000 |
|
- |
| 5.3-Table 3 (Vertically static cast wire bars)(thickness ) |
- |
5000 |
|
- |
| 5.3-Table 3 (Vertically static cast wire bars)(Other dimention) |
- |
5000 |
|
- |
| 5.4-Table 3 (Ingots)(Mass) |
- |
5000 |
|
- |
| 5.4-Table 3 (Cast cakes)(Mass) |
- |
5000 |
|
- |
| 5.3-Table 3 (Cast cakes)(Width) |
- |
5000 |
|
- |
| 5.3-Table 3 (Cast cakes)(thickness ) |
- |
5000 |
|
- |
| 5.3-Table 3 (Cast cakes)(Deviation from straightness per 1000 mm length) |
- |
5000 |
|
- |
| 7.1 - Table 4(Copper + Silver(By difference)-IS440) |
- |
5000 |
|
- |
| 7.1 - Table 4(Silver- IS 440) |
- |
5000 |
|
- |
| 7.1 - Table 4(Copper (any Silver present to be counted as copper)-IS440) |
- |
5000 |
|
- |
| 7.1 - Table 4(Phosphorus- IS 440) |
- |
5000 |
|
- |
| 7.1 - Table 4(Arsenic- IS440) |
- |
5000 |
|
- |
| 7.1 - Table 4(Antimony-IS440) |
- |
5000 |
|
- |
| 7.1 - Table 4(Bismuth-IS 440) |
- |
5000 |
|
- |
| 7.1 - Table 4(Iron IS 440) |
- |
5000 |
|
- |
| 7.1 - Table 4(Lead IS 440) |
- |
5000 |
|
- |
| 7.1 - Table 4(Nickel IS 440) |
- |
5000 |
|
- |
| 7.1 - Table 4(Oxygen IS 440) |
- |
5000 |
|
- |
| 7.1 - Table 4(Selenium - IS 440) |
- |
5000 |
|
- |
| 7.1 - Table 4(Sulphur- IS 440) |
- |
5000 |
|
- |
| 7.1 - Table 4(Tellurium- IS 440) |
- |
5000 |
|
- |
| 7.1 - Table 4(Tin - IS 440) |
- |
5000 |
|
- |
| 7.1 - Table 4(Znic-IS 440) |
- |
5000 |
|
- |
| 7.1 - Table 4(Selenium + Telluuium- IS 440) |
- |
5000 |
|
- |
| 7.1 - Table 4(Total Impurities- IS 440) |
- |
5000 |
|
- |
| 8.1(FREEDOM FROM DEFECTS) |
- |
5000 |
|
- |
| 8.2(FREEDOM FROM DEFECTS) |
- |
5000 |
|
- |
| 9.1- Table 5(Mass Resistivity- IS 3635) |
- |
5000 |
|
- |
| 10(HYDROGEN EMBRITTLEMENT TEST- IS 191) |
- |
5000 |
|
- |
| 9.1 , 9.2 & 10(Resistivity & HYDROGEN EMBRITTLEMENT TEST) |
- |
5000 |
|
- |
| 9.1 , 9.2 & 10(Resistivity & HYDROGEN EMBRITTLEMENT TEST) |
- |
5000 |
|
- |
| 13(Marking) |
- |
5000 |
|
- |
| 13(Marking) |
- |
5000 |
|
- |
| 13(Marking) |
- |
5000 |
|
- |
|
13 May, 2028 |
- Included w.e.f 01.08.2025 |
| 1913 |
TUV SUD SOUTH ASIA PRIVATE LIMITED RANIPET
| 6191806
| IS 13893 (1994) |
Polyurethane soles semirigid - specification |
- |
4900 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4.1(Design) |
- |
500 |
|
- |
| 4.2 (Amendment 2)(Thickness) |
- |
400 |
|
- |
| 4.3.1 Table 1 i) (Amendment 2)(Relative Density) |
- |
400 |
|
- |
| 4.3.1 Table 1 ii) (Amendment 2)(Hardness, degree, Shore A) |
- |
400 |
|
- |
| 4.3.1 Table 1 iii) (Amendment 2)(Abrasion Resistance at applied force of 10 N) |
- |
960 |
|
- |
| 4.3.1 Table 1 iv) (Amendment 2)(Flexing Resistance, Bennewart method) |
- |
1200 |
|
- |
| 4.3.1 Table 1 v) (Amendment 2)(Hydrolysis Resistance, cut growth after 150000 flexes) |
- |
5200 |
|
- |
| 4.3.1 Table 1 vi) (Amendment 2)(Tensile Strength) |
- |
480 |
|
- |
| 4.3.1 Table 1 vii) (Amendment 2)(Elongation at break) |
- |
480 |
|
- |
| 4.3.1 Table 1 viii) (Amendment 2)(Tear Strength (average force)) |
- |
480 |
|
- |
| Cl.5, 5.1, 5.2(Packing And Marking) |
- |
500 |
|
- |
| 4.3.2(Ageing test) |
- |
4000 |
|
- |
|
02 Dec, 2028 |
- - |
| 1914 |
NATIONAL TESTING BUREAU, GHAZIABAD
| 8186826
| IS 302 : Part 2 : Sec 59 (2024) |
Household and Similar Electrical Appliances â Safety Part 2 Particular Requirements Section 59 Insect Killers (First Revision) |
- |
20000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4(General) |
- |
0 |
|
- |
| 5(General conditions for the tests) |
- |
0 |
|
- |
| 6(Classification) |
- |
500 |
|
- |
| 7(Marking and instructions) |
- |
500 |
|
- |
| 8("8 PROTECTION AGAINST ELECTRIC
SHOCK ") |
- |
1000 |
|
- |
| 10(Power input and current) |
- |
1000 |
|
- |
| 11(Heating) |
- |
1000 |
|
- |
| 11.3(Heating) |
- |
1000 |
|
- |
| 11.7(Heating) |
- |
1000 |
|
- |
| 11.8(Heating) |
- |
1000 |
|
- |
| 12(Charging of metal-ion batteries) |
- |
0 |
|
- |
| 13(Leakage current and electric strength at operating temperature) |
- |
1000 |
|
- |
| 14(Transient overvoltages) |
- |
2000 |
|
- |
| 15(MOISTURE RESISTANCE) |
- |
1000 |
|
- |
| 16(Leakage current and electric strength) |
- |
500 |
|
- |
| 17(Overload protection of transformers and associated circuits) |
- |
500 |
|
- |
| 19(ABNORMAL OPERATION) |
- |
500 |
|
- |
| 19.11.4.1(Electrostatic discharges) |
- |
500 |
|
- |
| 19.11.4.2(Radiated fields) |
- |
0 |
|
- |
| 19.11.4.3(Fast transient bursts) |
- |
0 |
|
- |
| 19.11.4.4(Voltage surges) |
- |
0 |
|
- |
| 19.11.4.5(Injected currents) |
- |
0 |
|
- |
| 19.11.4.6(Class 3 Voltage dips and interruptions) |
- |
0 |
|
- |
| 19.11.4.7(Mains signals) |
- |
0 |
|
- |
| 20("STABILITY AND MECHANICAL
HAZARDS") |
- |
500 |
|
- |
| 21(MECHANICAL STRENGTH) |
- |
500 |
|
- |
| 22(CONSTRUCTION) |
- |
1000 |
|
- |
| 23(INTERNAL WIRING) |
- |
1000 |
|
- |
| 24(COMPONENTS) |
- |
0 |
|
- |
| 25("SUPPLY CONNECTION AND EXTERNAL
FLEXIBLE CABLES AND CORDS ") |
- |
1000 |
|
- |
| 26("TERMINALS FOR EXTERNAL
CONDUCTORS") |
- |
1000 |
|
- |
| 27(PROVISION FOR EARTHING) |
- |
1000 |
|
- |
| 28(SCREWS AND CONNECTIONS) |
- |
1000 |
|
- |
| 30("RESISTANCE TO HEAT, FIRE AND
TRACKING ") |
- |
1000 |
|
- |
| 31(RESISTANCE TO RUSTING) |
- |
1000 |
|
- |
| 32(Radiation, toxicity and similar hazards) |
- |
0 |
|
- |
| 29(Clearances, creepage distances and solid insulation) |
- |
1000 |
|
- |
|
10 Jul, 2028 |
- Included w.e.f. 04.08.2025
Exclusion: "19.11.4.1 (Electrostatic discharges)
19.11.4.2 (Radiated fields)
19.11.4.3 (Fast transient bursts)
19.11.4.4 (Voltage surges)
19.11.4.5 (Injected currents)
19.11.4.6 (Class 3 Voltage dips and interruptions)
19.11.4.7 (Mains signals)
24 (COMPONENTS)
32 (Radiation, toxicity and similar hazards)
" |
| 1915 |
TUV SUD SOUTH ASIA PRIVATE LIMITED RANIPET
| 6191806
| IS 17043 : Part 2 (2024) |
Shoes: Shoes for General Purpose |
- |
59900 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl-5.1(Shape and Design) |
- |
400 |
|
- |
| Cl-5.3(Material) |
- |
500 |
|
- |
| Cl-5.4, Table-1 (i)(Bond strength, N/mm, Min Upper to outsole, N/mm, Min) |
- |
600 |
|
- |
| Cl-5.4, Table-1 (ii)(Inter layer bond strength,= N/mm, Min Midsole to outsole, N/mm, Min) |
- |
600 |
|
- |
| Cl-5.4, Table-1 (iii)(Whole shoe flexing, flexes) |
- |
1600 |
|
- |
| Cl-5.4, Table-1 (iv)(Water proofness on complete shoe) |
- |
2000 |
|
- |
| Cl-5.4, Table-1 (v)(Slip resistance, Cof(1), Min dry and wet* (quarry tile)) |
- |
2800 |
|
- |
| Cl-5.4, Table-1 (vi)(Attachment strength of strap and buckle/D-ring N) |
- |
600 |
|
- |
| Cl-5.4, Table-1 (vii)(Attachment strength of strap and velcro , N, Min) |
- |
600 |
|
- |
| Cl-5.4, Table-1 (viii)(Strength of eyelet attachment, N, Min) |
- |
600 |
|
- |
| Cl-5.4, Table-1 (ix)(Heel pull off strength, N, Min) |
- |
600 |
|
- |
| Cl-5.4, Table-1 (x)(Top piece attachment strength, N, Min) |
- |
600 |
|
- |
| Cl-5.4, Table-1 (xi)(Seam strength, N/mm, Min) |
- |
440 |
|
- |
| Cl-5.4, Table-1 (xii)(Whole shoe topline strength, N, Min) |
- |
600 |
|
- |
| Cl-5.4, Table-1 (xiii)(Abrasion resistance (volume loss), mm3) |
- |
960 |
|
- |
| Cl-5.4, Table-1 (xvi)(Hydrolysis resistance,(4) cut growth at 150 000 flexes, mm, Max) |
- |
5200 |
|
- |
| Cl-6.1.1, Table-2 (i)(Tear trength, N) |
- |
440 |
|
- |
| Cl-6.1.1, Table-2 (ii)(Flexing resistance, flexes) |
- |
1000 |
|
- |
| Cl-6.1.1, Table-2 (iii)(Colour fastness to rubbing (marring/staining)) |
- |
480 |
|
- |
| Cl-6.1.1, Table-2 (iv)(Colour fastness to water (contact method- multi fabrics)) |
- |
480 |
|
- |
| Cl-6.1.1, Table-2 (v)(Water vapour permeability,mg/cm2 /h, Min Water vapour coefficient,mg/cm2 , Min) |
- |
1000 |
|
- |
| Cl-6.1.1, Table-2 (vi)(Stitch tear strength, N/mm, Min) |
- |
440 |
|
- |
| Cl-6.1.1, Table-2 (vii)(Abrasion resistance) |
- |
800 |
|
- |
| Cl-6.1.2, Table-3 (i)(Colour fastness to light, Marring, Min) |
- |
800 |
|
- |
| Cl-6.1.2, Table-3 (ii)(Water resistance) |
- |
800 |
|
- |
| Cl-6.1.2, Table-3 (iii)(Flexing resistance, flexes at (-) 5 °C 25 000 flexes) |
- |
1200 |
|
- |
| Cl-6.1.3, Table- 4 (i)(Breaking strength, N/mm, Min Elongation at break, percent, Min) |
- |
440 |
|
- |
| Cl-6.1.3, Table- 4 (ii)(Tear Strength, N, Min) |
- |
440 |
|
- |
| Cl-6.1.3, Table- 4 (iii)(Strength at needle perforation, N/mm, Min) |
- |
440 |
|
- |
| Cl-6.1.3, Table- 4 (iv)(Flexing resistance, Flexes) |
- |
1000 |
|
- |
| Cl-6.1.3, Table- 4 (v)(Water vapour permeability (WVP), mg/cm2 /h, Min) |
- |
1000 |
|
- |
| Cl-6.1.3, Table- 4 (vi)(Hydrolysis resistance) |
- |
5200 |
|
- |
| Cl-6.1.3, Table- 4 (vii)(Abrasion resistance) |
- |
800 |
|
- |
| Cl-6.1.4, Table-5 (i)(Colour fastness to light, Marring, Min) |
- |
800 |
|
- |
| Cl-6.1.4, Table- 5 (ii)(Flexing resistance, flexes at (-) 5 ºC, s 25 000 flexes) |
- |
1200 |
|
- |
| Cl-6.2, Table-6 (i)(Tear strength, N, Min) |
- |
440 |
|
- |
| Cl-6.2, Table-6 (ii)(Abrasion resistance) |
- |
800 |
|
- |
| Cl-6.2, Table-6 (iii)(Colour fastness rubbing (crocking)) |
- |
480 |
|
- |
| Cl-6.2, Table-6 (iv)(Colour fastness to perspiration) |
- |
480 |
|
- |
| Cl-6.2, Table-6 (v)(Water vapour permeability, mg/cm2 /h, Min Water vapour coefficient, mg/cm2, Min) |
- |
1800 |
|
- |
| Cl-6.3, Table-7 (i)(Flexing index, Min) |
- |
800 |
|
- |
| Cl-6.3, Table-7 (ii)(Abrasion resistance at 400 cycles) |
- |
800 |
|
- |
| Cl-6.3, Table-7 (iii)(Water absorption, mg/cm2 , Min
Water desorption, percent, Min) |
- |
800 |
|
- |
| Cl-6.4, Table-8 (i)(Thickness, mm, Min) |
- |
400 |
|
- |
| Cl-6.4, Table-8 (ii)(Abrasion resistance) |
- |
800 |
|
- |
| Cl-6.4, Table-8 (iii)(Water absorption, mg/cm2 , Min
Water desorption, percent, Min) |
- |
800 |
|
- |
| Cl-6.5.1, , Table-9 (i)(Flexing resistance) |
- |
1200 |
|
- |
| Cl-6.5.1, , Table-9 (ii)(Hydrolysis resistance, cut growth at 150 000 flexes, mm, Max) |
- |
5200 |
|
- |
| Cl-6.5.1, , Table-9 (iii)(Compression set, percent, Max) |
- |
800 |
|
- |
| Cl-6.5.2.1, Table-10 (i)(Grain crack index, Min) |
- |
500 |
|
- |
| Cl-6.5.2.1, Table-10 (ii)(Density, g/cm3 , Min) |
- |
400 |
|
- |
| Cl-6.5.2.1, Table-10 (iii)(Abrasion resistance, mm/kcs, Max) |
- |
1200 |
|
- |
| Cl-6.5.2.2, Table-11 (i)(Water resistance, (dynamic method)) |
- |
1000 |
|
- |
| Cl-6.5.2.3, Table-12 (i)(Hardness, Min) |
- |
400 |
|
- |
| Cl-6.5.2.3, Table-12 (ii)(Density, g/cm3 , Max) |
- |
400 |
|
- |
| Cl-6.5.2.3, Table-12 (iii)(Abrasion resistance (volume loss), mm3 , Max) |
- |
960 |
|
- |
| Cl-6.5.2.3, Table-12 (iv)(Bond Strength between Rubber top-lift and adjacent material, N/mm, Min) |
- |
600 |
|
- |
| Cl-6.6, Table-13 (i)(Heat shrinkage, percent, Max) |
- |
800 |
|
- |
| Cl-6.6, Table-13 (ii)(Split tear strength, kg/25 mm, Min) |
- |
480 |
|
- |
| Cl-6.6, Table-13 (iii)(Compression set, percent, Max) |
- |
800 |
|
- |
| Cl-6.7, Table-14 (i)(Hardness, N) |
- |
400 |
|
- |
| Cl-6.7, Table-14 (ii)(Resilience, percent) |
- |
1000 |
|
- |
| Cl-6.7, Table-14 (iii)(Moisture resistance, percent) |
- |
1000 |
|
- |
| Cl-6.7, Table-14 (iv)(Area shape retention, percent
(a) Initial, Min
b) After 10 collapsing load, Min) |
- |
1000 |
|
- |
| Cl-6.7, Table-14 (v)(Adhesion strength, N/mm) |
- |
1000 |
|
- |
| Cl-6.8, Table-15 (i)(Peel strength, N/mm
a) Initial, Min
b) After 5 000 wear cycles, Min) |
- |
2750 |
|
- |
| Cl- 6.8, Table-15 (ii)(a) Shear strength, kPa
b) Initial, Min) |
- |
600 |
|
- |
| Cl- 6.9, Table-16 (i)(Limit of useful extension, percent,
Min) |
- |
1000 |
|
- |
| Cl- 6.9, Table-16 (ii)(Needle strength, N/mm, Min) |
- |
440 |
|
- |
| Cl-6.10, Table-17 (i)(Lace breaking strength, N, Min) |
- |
600 |
|
- |
| Cl-6.10, Table-17 (ii)(Lace tag strength, N, Min) |
- |
600 |
|
- |
| Cl-6.10, Table-17 (iii)(Lace to lace abrasion resistance, cycles) |
- |
1200 |
|
- |
| Cl-6.10, Table-17 (iv)(Colour fastness to water for lace contact methodstaining Gray scale rate , Min) |
- |
480 |
|
- |
| Cl-6.10, Table-17 (v)(Corrosion resistance) |
- |
800 |
|
- |
| Cl-6.11, Table-18 (i)(Fatigue resistance, cycles, Min) |
- |
480 |
|
- |
| Cl-6.11, Table-18 (ii)(Security of puller attachment strength, N, Min) |
- |
480 |
|
- |
| Cl-6.11, Table-18 (iii)(Lateral load, N, Min) |
- |
480 |
|
- |
| Cl-6.11, Table-18 (iv)(End attachment strength, N, Min) |
- |
480 |
|
- |
| CL. 5.4, Table 1, Sl No (xv)("Lead content (as Pb) ppm, Max
(applicable only for PVC") |
- |
1200 |
|
- |
| Cl-5.4, Table-1 (xiv) (IS - 17011,Table - 1(i)(Allergenic and carcinogenic disperse dyes) |
- |
2800 |
|
- |
| Cl-5.4, Table-1 (xiv) (IS - 17011,Table - 1(ii)(Aromatic amines released from Azo dyes (each individual amine)) |
- |
2400 |
|
- |
| Cl-5.4, Table-1 (xiv) (IS - 17011,Table - 1(iii)(Aromatic amines released from Azo dyes (each individual amine)) |
- |
2400 |
|
- |
| Cl-5.4, Table-1 (xiv) (IS - 17011,Table - 1(iv)(Chromium (VI)) |
- |
1200 |
|
- |
| Cl-5.4, Table-1 (xiv) (IS - 17011,Table - 1(v)(Dimethyl fumarate (DMFU)) |
- |
2800 |
|
- |
| Cl-5.4, Table-1 (xiv) (IS - 17011,Table - 1(vi)(Formaldehyde (free or released by partial hydrolysis)) |
- |
960 |
|
- |
| Cl-5.4, Table-1 (xiv) (IS - 17011,Table - 1(vii)(Formaldehyde) |
- |
960 |
|
- |
| Cl-5.4, Table-1 (xiv) (IS - 17011,Table - 1(viii)(Organotin compounds) |
- |
4000 |
|
- |
| Cl-5.4, Table-1 (xiv) (IS - 17011,Table - 1(ix)(PCP-TeCP-TriCP polychlorophenols) |
- |
2800 |
|
- |
| Cl-5.4, Table-1 (xiv) (IS - 17011,Table - 1(x)(pH) |
- |
400 |
|
- |
| Cl-5.4, Table-1 (xiv) (IS - 17011,Table - 1(xi)(Phthalates (each individual phthalate)) |
- |
6400 |
|
- |
| Cl-5.4, Table-1 (xiv) (IS - 17011,Table - 1(xii)(Nickel, on skin contact) |
- |
1600 |
|
- |
| Cl.1.4.1 of IS 17011 (Table B Sl I )(Phthalate: DINP) |
- |
2800 |
|
- |
| Cl.1.4.1 of IS 17011 (Table B Sl II )(Phthalate:: DNOP) |
- |
2800 |
|
- |
| Cl.1.4.1 of IS 17011 (Table B Sl III )(Phthalate: DEHP) |
- |
2800 |
|
- |
| Cl.1.4.1 of IS 17011 (Table B Sl IV )(Phthalate: DIDP) |
- |
2800 |
|
- |
| Cl.1.4.1 of IS 17011 (Table B Sl V)(Phthalate: BBP) |
- |
2800 |
|
- |
| Cl.1.4.1 of IS 17011 (Table B Sl VI )(Phthalate:DBP) |
- |
2800 |
|
- |
| Cl.1.4.1 of IS 17011 (Table B Sl VII )(Phthalate: DIBP) |
- |
2800 |
|
- |
| Cl.4.1 (Annex-A Sl I )(Organotin: Dibutyltin) |
- |
2800 |
|
- |
| Cl.4.1 (Annex-A Sl II )(Organotin: Dibutyltin Dichloride) |
- |
2800 |
|
- |
| Cl.4.1 (Annex-A Sl III )(Organotin: Dioctyltin) |
- |
2800 |
|
- |
| Shoes: Shoes for General Purpose(Organotin: Monobutyltin) |
- |
2800 |
|
- |
| Cl.4.1 (Annex-A Sl V )(Organotin: Tributyltin) |
- |
2800 |
|
- |
| Cl.4.1 (Annex-A Sl VI)(Organotin: Triphenyltin) |
- |
2800 |
|
- |
| Cl.4.1 (Annex-A Sl VII )(Organotin: Monoctyltin) |
- |
2800 |
|
- |
| Cl.4.1 (Annex-A Sl VIII)(Organotin: Bis (tributyltin) oxide) |
- |
2800 |
|
- |
| Cl.1.4.1 of IS 17011(DMFU) |
- |
2800 |
|
- |
| Cl. No.8.6.1,Table 1 of IS 17011(Chromium) |
- |
1200 |
|
- |
| Cl. No.8.6.1,Table 1 of IS 17011(Formaldehyde (free or released by partial hydrolysis)) |
- |
960 |
|
- |
| Cl. No.8.6.1,Table 1 of IS 17011(pH) |
- |
400 |
|
- |
| Cl. No.8.6.1,Table 1 of IS 17011(Nickel, on skin contact 2-(thiocyanomethylthio) -benzothiazole (TCMTB)) |
- |
1600 |
|
- |
| Cl.4.1 (Table B-1 Sl I)(Aromatic Amines: 4-aminobiphenyl) |
- |
2400 |
|
- |
| Cl.4.1 (Table B-1 Sl II)(Aromatic Amines: Benzidine) |
- |
2400 |
|
- |
| Cl.4.1 (Table B-1 Sl III)(Aromatic Amines: 4-chloro-o-toluidine) |
- |
2400 |
|
- |
| Cl.4.1 (Table B-1 Sl IV)(Aromatic Amines: 2-naphthylamine) |
- |
2400 |
|
- |
| Cl.4.1 (Table B-1 Sl V)(Aromatic Amines :o- aminoazotoluene) |
- |
2400 |
|
- |
| Cl.4.1 (Table B-1 Sl VI)(Aromatic Amines: 2-amino-4-nitrotoluenem) |
- |
2400 |
|
- |
| Cl.4.1 (Table B-1 Sl VII)(Aromatic Amines: p-chloroaniline) |
- |
2400 |
|
- |
| Cl.4.1 (Table B-1 Sl VIII)(Aromatic Amines: 2,4-diaminoanisole) |
- |
2400 |
|
- |
| Cl.4.1 (Table B-1 Sl X)(Aromatic Amines : 3,3’-dichlorobenzidine) |
- |
2400 |
|
- |
| Cl.4.1 (Table B-1 Sl XI)(Aromatic Amines : 3,3’-dimethoxybenzidine) |
- |
2400 |
|
- |
| Cl.4.1 (Table B-1 Sl XII)(Aromatic Amines : 3,3’-dimethylbenzidine) |
- |
2400 |
|
- |
| Cl.4.1 (Table B-1 Sl XIII)(Aromatic Amines: 3,3’-dimethyl-4,4’-diaminodiphenylmethane) |
- |
2400 |
|
- |
| Cl.4.1 (Table B-1 Sl XIV)(Aromatic Amines : p-cresi) |
- |
2400 |
|
- |
| Cl.4.1 (Table B-1 Sl XV)(Aromatic Amines : 4,4’-methylene-bis(2-chloroaniline):) |
- |
2400 |
|
- |
| Cl.4.1 (Table B-1 Sl XVI)(Aromatic Amines :4,4’-oxydianiline) |
- |
2400 |
|
- |
| Cl.4.1 (Table B-1 Sl XVII)(Aromatic Amines:4,4’-thiodianiline) |
- |
2400 |
|
- |
| Cl.4.1 (Table B-1 Sl XVIII)(Aromatic Amines :o-toluidine:) |
- |
2400 |
|
- |
| Cl.4.1 (Table B-1 Sl XIX)(Aromatic Amines: 2,4-toluylendiamine) |
- |
2400 |
|
- |
| Cl.4.1 (Table B-1 Sl XX)(Aromatic Amines: 2,4,5-trimethylaniline) |
- |
2400 |
|
- |
| Cl.4.1 (Table B-1 Sl XXI)(Aromatic Amines :2,4-dimethylaniline) |
- |
2400 |
|
- |
| Cl.4.1 (Table B-1 Sl XXII)(Aromatic Amines: 2,6-dimethylaniline:) |
- |
2400 |
|
- |
| Cl.4.1 (Table B-1 Sl XXIV)(Aromatic Amines :4-aminoazobenzene) |
- |
2400 |
|
- |
| Cl.4.1 (Table B-3 Sl I)(Allergenic Disperse Dyes :Disperse blue 3) |
- |
2800 |
|
- |
| Cl.4.1 (Table B-3 Sl II)(Allergenic Disperse Dyes :Disperse blue 7) |
- |
280 |
|
- |
| Cl.4.1 (Table B-3 Sl III)(Allergenic Disperse Dyes :Disperse blue 26) |
- |
2800 |
|
- |
| Cl.4.1 (Table B-3 Sl IV)(Allergenic Disperse Dyes :Disperse blue 102) |
- |
2800 |
|
- |
| Cl.4.1 (Table B-3 Sl V)(Allergenic Disperse Dyes: Disperse brown 1) |
- |
2800 |
|
- |
| Cl.4.1 (Table B-3 Sl VI)(Allergenic Disperse Dyes :Disperse yellow 1) |
- |
2800 |
|
- |
| Cl.4.1 (Table B-3 Sl VII)(Allergenic Disperse Dyes :Disperse yellow 9) |
- |
2800 |
|
- |
| Cl.4.1 (Table B-3 Sl VIII)(Allergenic Disperse Dyes :Disperse yellow 39) |
- |
2800 |
|
- |
| Cl.4.1 (Table B-3 Sl IX)(Allergenic Disperse Dyes :Disperse yellow 49) |
- |
2800 |
|
- |
| Cl.4.1 (Table B-3 Sl X)(Allergenic Disperse Dyes :Disperse orange 1) |
- |
2800 |
|
- |
| Cl.4.1 (Table B-3 Sl XI)(Allergenic Disperse Dyes :Disperse red 11) |
- |
2800 |
|
- |
| Cl.4.1 (Table B-3 Sl XII)(Allergenic Disperse Dyes :Disperse red 17) |
- |
2800 |
|
- |
| Cl.4.1 (Table B-3 Sl XIII)(Allergenic Disperse Dyes :Disperse yellow 7) |
- |
2800 |
|
- |
| Cl.4.1 (Table B-3 Sl XIV)(Allergenic Disperse Dyes :Disperse yellow 56) |
- |
2800 |
|
- |
| Cl.4.1 (Table B-3 Sl XV)(Allergenic Disperse Dyes :Disperse red 151) |
- |
2800 |
|
- |
| Cl.4.1 (Table B-3 Sl XVI)(Allergenic Disperse Dyes :Solvent red 23) |
- |
2800 |
|
- |
| Cl.4.1 (Table B-4 Sl I)(Carcinogenic Disperse Dyes :Navy blue) |
- |
2800 |
|
- |
| Cl.4.1 (Table B-4 Sl II)(Carcinogenic Disperse Dyes: Disperse blue 1) |
- |
2800 |
|
- |
| Cl.4.1 (Table B-4 Sl III)(Carcinogenic Disperse Dyes: Disperse blue 35) |
- |
2800 |
|
- |
| Cl.4.1 (Table B-4 Sl IV)(Carcinogenic Disperse Dyes :Disperse blue 106) |
- |
2800 |
|
- |
| Cl.4.1 (Table B-4 Sl V)(Carcinogenic Disperse Dyes: Disperse blue 124) |
- |
2800 |
|
- |
| Cl.4.1 (Table B-4 Sl VI)(Carcinogenic Disperse Dyes :Disperse yellow 3) |
- |
2800 |
|
- |
| Cl.4.1 (Table B-4 Sl VII)(Carcinogenic Disperse Dyes: Disperse orange 3) |
- |
2800 |
|
- |
| Cl.4.1 (Table B-4 Sl VIII)(Carcinogenic Disperse Dyes :Disperse orange 37/59/76a)) |
- |
2800 |
|
- |
| Cl.4.1 (Table B-4 Sl IX)(Carcinogenic Disperse Dyes :Disperse red 1) |
- |
2800 |
|
- |
| Cl.4.1 (Table B-4 Sl X)(Carcinogenic Disperse Dyes :Basic red 9) |
- |
2800 |
|
- |
| Cl.4.1 (Table B-4 Sl XI)(Carcinogenic Disperse Dyes :Violet 3) |
- |
2800 |
|
- |
| Cl.4.1 (Table B-4 Sl XII)(Carcinogenic Disperse Dyes Disperse yellow 23) |
- |
2800 |
|
- |
| Cl.4.1 (Table B-3)(Allergenic and Carcinogenic Disperse Dyes) |
- |
2800 |
|
- |
| Cl.4.1 (Table B-11)(PCP-TeCP-TriCP polychlorophenols) |
- |
2800 |
|
- |
| Cl-8.1(Marking) |
- |
500 |
|
- |
| CL. 5.4, Table 1, Sl No (xiv) & Table 1 of IS 17011(pH, Min) |
- |
400 |
|
- |
| Cl-5.4, Table-1 (xiv)(Chemical requirements(3)) |
- |
30000 |
|
- |
| Cl-5.4, Table-1 (xv)(Lead content (as Pb) ppm, Max) |
- |
1200 |
|
- |
| Cl.4.1 (Table B-1 Sl XXIII)(Aromatic Amines :2-methoxyaniline) |
- |
2800 |
|
- |
|
02 Dec, 2028 |
- - |
| 1916 |
TUV SUD SOUTH ASIA PRIVATE LIMITED RANIPET
| 6191806
| IS 10702 (2023) |
Hawai Chappal-Specification |
- |
33900 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4.1(Material) |
- |
500 |
|
- |
| 4.2(Length) |
- |
500 |
|
- |
| 4.3(Thickness) |
- |
400 |
|
- |
| Cl-4.4, Table -1 S. No-1 (i) (Amendment No-1)(Compression set at constant stress) |
- |
800 |
|
- |
| Cl-4.4, Table -1 S. No-1 (ii) (Amendment No-1)(Split tear strength) |
- |
480 |
|
- |
| Cl-4.4, Table -1 S. No-1 (iii) (a)(Amendment No-1)("Shrinkage at Shrinkage at 50 °C ± 1 °C for 2 h for polymeric material, percent, Max
") |
- |
800 |
|
- |
| Cl-4.4, Table -1 S. No-1 (iii)(b) (Amendment No-1)(Shrinkage at 100 °C ± 1 °C for 1 h for rubber, percent, Max) |
- |
800 |
|
- |
| Cl-4.4, Table -1 S. No-1 (v) (Amendment No-1)(Flexing resistance: Maximum cut growth,) |
- |
1200 |
|
- |
| Cl-4.4, Table -1 S. No-1 (iv) (Amendment No-1)(Abrasion resistance at applied force) |
- |
960 |
|
- |
| Cl-4.4, Table -1 S. No-1 (vi) (Amendment No-1)(Hydrolysis resistance:Maximum cut growth) |
- |
5200 |
|
- |
| Cl-4.4, Table -2 S. No-1 (i), a (Amendment No-1)("Breaking strength for Strap to strap
1-Solid strap
2-Cellular strap") |
- |
480 |
|
- |
| Cl-4.4, Table -2 S. No-1 (i), b (Amendment No-1)("Breaking strength for Toe portion to strap
1-Solid strap
2-Cellular strap") |
- |
480 |
|
- |
| Cl-4.4, Table -2 S. No-1 (i), c (Amendment No-1)("Elongation at break , percent, Min
1-Solid strap
2-Cellular strap") |
- |
480 |
|
- |
| Cl-4.4, Table -3 S. No-1 (i), (Amendment No-1)(Toe post attachment strength) |
- |
600 |
|
- |
| Cl-4.4, Table -3 S. No-1 (ii), (Amendment No-1)(Attachment strength of rear strap) |
- |
600 |
|
- |
| Cl-4.4, Table -3 S. No-1 (iii), (Amendment No-1)(Inter layer bond strength) |
- |
600 |
|
- |
| Cl. No.5.1,Table no.1 of IS 17011(i)(Allergenic and carcinogenic disperse dyes) |
- |
5600 |
|
- |
| Cl. No.5.1,Table no.1 of IS 17011(ii)(Aromatic amines released from Azo dyes (each individual amine)) |
- |
2400 |
|
- |
| Cl. No.5.1,Table no.1 of IS 17011(iii)(Aromatic amines released from Azo dyes (each individual amine)) |
- |
2400 |
|
- |
| Cl. No.5.1,Table no.1 of IS 17011(iv)(Chromium (VI)) |
- |
1200 |
|
- |
| Cl. No.5.1,Table no.1 of IS 17011(v)(Dimethyl fumarate (DMFU)) |
- |
2800 |
|
- |
| Cl. No.5.1,Table no.1 of IS 17011(vi)(Formaldehyde (free or released by partial hydrolysis)) |
- |
960 |
|
- |
| Cl. No.5.1,Table no.1 of IS 17011(vii)(Formaldehyde) |
- |
960 |
|
- |
| Cl. No.5.1,Table no.1 of IS 17011(viii)(Organotin compounds) |
- |
4000 |
|
- |
| Cl. No.5.1,Table no.1 of IS 17011(ix)(PCP-TeCP-TriCP polychlorophenols) |
- |
2800 |
|
- |
| Cl. No.5.1,Table no.1 of IS 17011(x)(pH) |
- |
400 |
|
- |
| Cl. No.5.1,Table no.1 of IS 17011(xi)(Phthalates (each individual phthalate)) |
- |
4000 |
|
- |
| Cl. No.5.1,Table no.1 of IS 17011(xii)(Nickel, on skin contact 2-(thiocyanomethylthio) -benzothiazole (TCMTB)) |
- |
1600 |
|
- |
| Cl.No. 5.2(lead content) |
- |
1200 |
|
- |
| 5(CHEMICAL REQUIREMENT FOR HAWAI CHAPPAL) |
- |
23100 |
|
- |
| Cl-4.4, Table -1 S. No-1 (vii) (Amendment No-1)(Chemical requirements) |
- |
23100 |
|
- |
| Cl-4.4, Table -1 S. No-1 (viii) (Amendment No-1)("Lead content (as Pb),
ppm, Max") |
- |
1200 |
|
- |
| Cl-4.4, Table -2 S. No-1 (ii), (Amendment No-1)(Chemical requirements) |
- |
1200 |
|
Only for Lead test |
| Cl-4.4, Table -2 S. No-1 (iii), (Amendment No-1)(Lead content (as Pb), in ppm, Max) |
- |
1200 |
|
- |
| Cl.4.4 - Table No 1 - Sl. No.-vii(pH- IS 1390:2022) |
- |
400 |
|
- |
| Cl.4.4 - Table No 1 - Sl. No.-viii("Lead Content (as Pb) (applicable for PVC only)
- IS 12240 (Part 5) : 1988") |
- |
1200 |
|
- |
| Cl.1.4.1 of IS 17011 (Table B Sl I )(Phthalate: DINP) |
- |
2800 |
|
- |
| Cl.1.4.1 of IS 17011 (Table B Sl II )(Phthalate:: DNOP) |
- |
2800 |
|
- |
| Cl.1.4.1 of IS 17011 (Table B Sl III )(Phthalate: DEHP) |
- |
2800 |
|
- |
| Cl.1.4.1 of IS 17011 (Table B Sl IV )(Phthalate: DIDP) |
- |
2800 |
|
- |
| Cl.1.4.1 of IS 17011 (Table B Sl V)(Phthalate: BBP) |
- |
2800 |
|
- |
| Cl.1.4.1 of IS 17011 (Table B Sl VI )(Phthalate:DBP) |
- |
2800 |
|
- |
| Cl.1.4.1 of IS 17011 (Table B Sl VII )(Phthalate: DIBP) |
- |
2800 |
|
- |
| Cl.4.1 (Annex-A Sl I )(Organotin: Dibutyltin) |
- |
4000 |
|
- |
| Cl.4.1 (Annex-A Sl II )(Organotin: Dibutyltin Dichloride) |
- |
4000 |
|
- |
| Cl.4.1 (Annex-A Sl III )(Organotin: Dioctyltin) |
- |
4000 |
|
- |
| Cl.4.1 (Annex-A Sl IV)(Organotin: Monobutyltin) |
- |
4000 |
|
- |
| Cl.4.1 (Annex-A Sl V )(Organotin: Tributyltin) |
- |
4000 |
|
- |
| Cl.4.1 (Annex-A Sl VI)(Organotin: Triphenyltin) |
- |
4000 |
|
- |
| Cl.4.1 (Annex-A Sl VII )(Organotin: Monoctyltin) |
- |
4000 |
|
- |
| Cl.4.1 (Annex-A Sl VIII)(Organotin: Bis (tributyltin) oxide) |
- |
4000 |
|
- |
| Hawai Chappal-Specification(Formaldehyde (free or released by partial hydrolysis)) |
- |
960 |
|
- |
| Cl. No.8.6.1,Table 1 of IS 17011(Nickel, on skin contact 2-(thiocyanomethylthio) -benzothiazole (TCMTB)) |
- |
1600 |
|
- |
| Cl.8 - Table No 1(Lead Content (as Pb) (applicable for PVC only) - IS 12240 (Part 5) : 1988) |
- |
1200 |
|
- |
| Cl.4.1 (Table B-3)(Allergenic and Carcinogenic Disperse Dyes) |
- |
5600 |
|
- |
| Cl.4.1 (Table B-1 Sl I)(Aromatic Amines: 4-aminobiphenyl) |
- |
2400 |
|
- |
| Cl.4.1 (Table B-1 Sl II)(Aromatic Amines: Benzidine) |
- |
2400 |
|
- |
| Cl.4.1 (Table B-1 Sl III)(Aromatic Amines: 4-chloro-o-toluidine) |
- |
2400 |
|
- |
| Cl.4.1 (Table B-1 Sl IV)(Aromatic Amines: 2-naphthylamine) |
- |
2400 |
|
- |
| Cl.4.1 (Table B-1 Sl V)(Aromatic Amines :o-aminoazotoluene) |
- |
2400 |
|
- |
| Cl.4.1 (Table B-1 Sl VI)(Aromatic Amines: 2-amino-4-nitrotoluenem) |
- |
2400 |
|
- |
| Cl.4.1 (Table B-1 Sl VII)(Aromatic Amines: p-chloroaniline) |
- |
2400 |
|
- |
| Cl.4.1 (Table B-1 Sl VIII)(Aromatic Amines: 2,4-diaminoanisole) |
- |
2400 |
|
- |
| Cl.4.1 (Table B-1 Sl IX)(Aromatic Amines : 4,4’- diaminodiphenylmethane:) |
- |
2400 |
|
- |
| Cl.4.1 (Table B-1 Sl X)(Aromatic Amines : 3,3’-dichlorobenzidine) |
- |
2400 |
|
- |
| Cl.4.1 (Table B-1 Sl XI)(Aromatic Amines : 3,3’-dimethoxybenzidine) |
- |
2400 |
|
- |
| Cl.4.1 (Table B-1 Sl XII)(Aromatic Amines : 3,3’-dimethylbenzidine) |
- |
2400 |
|
- |
| Cl.4.1 (Table B-1 Sl XIII)(Aromatic Amines: 3,3’-dimethyl-4,4’-diaminodiphenylmethane) |
- |
2400 |
|
- |
| Cl.4.1 (Table B-1 Sl XIV)(Aromatic Amines : p-cresidine) |
- |
2400 |
|
- |
| Cl.4.1 (Table B-1 Sl XV)(Aromatic Amines : 4,4’-methylene-bis(2-chloroaniline):) |
- |
2400 |
|
- |
| Cl.4.1 (Table B-1 Sl XVI)(Aromatic Amines :4,4’-oxydianiline) |
- |
2400 |
|
- |
| Cl.4.1 (Table B-1 Sl XVII)(Aromatic Amines:4,4’-thiodianiline) |
- |
2400 |
|
- |
| Cl.4.1 (Table B-1 Sl XVIII)(Aromatic Amines :o-toluidine:) |
- |
2400 |
|
- |
| Cl.4.1 (Table B-1 Sl XIX)(Aromatic Amines: 2,4-toluylendiamine) |
- |
2400 |
|
- |
| Cl.4.1 (Table B-1 Sl XX)(Aromatic Amines: 2,4,5-trimethylaniline) |
- |
2400 |
|
- |
| Cl.4.1 (Table B-1 Sl XXI)(Aromatic Amines :2,4-dimethylaniline) |
- |
2400 |
|
- |
| Cl.4.1 (Table B-1 Sl XXII)(Aromatic Amines: 2,6-dimethylaniline:) |
- |
2400 |
|
- |
| Cl.4.1 (Table B-1 Sl XXIII)(Aromatic Amines :2-methoxyaniline) |
- |
2400 |
|
- |
| Cl.4.1 (Table B-1 Sl XXIV)(Aromatic Amines :4-aminoazobenzene) |
- |
2400 |
|
- |
| Cl-4 ((Amendment No-1)(Category And Type) |
- |
500 |
|
Actual Charge based on Material |
| 6(MARKING AND PACKING) |
- |
500 |
|
Actual Charge based on Material |
| Clause 4.1 - 4.1.1(Bottom Material) |
- |
500 |
|
Actual Charge based on Material |
| Clause 4.1 - 4.1.2(Strap Material) |
- |
500 |
|
Actual Charge based on Material |
| Clause 4.1 - 4.1.3(Material) |
- |
500 |
|
Actual Charge based on Material |
| Clause 4.3 - 4.3.2(Thickness) |
- |
400 |
|
Actual Charge based on Material |
| Clause 4.1 - 4.1.4(Material) |
- |
500 |
|
Actual Charge based on Material |
| Clause 4.2(Material) |
- |
500 |
|
Actual Charge based on Material |
|
02 Dec, 2028 |
- - |
| 1917 |
TUV SUD SOUTH ASIA PRIVATE LIMITED RANIPET
| 6191806
| IS 3735 (1996) |
Canvas Shoes, Rubber Sole |
- |
15900 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl.4.5 Consolidation Test
IS 3400 (Part 5) : 1986 (From the quarter, cut a strip of 25.0 ± 0.5 mm width along the leagth of the boot
and of sufficient length to permit separation over a length of 75 mm. Carry out the test on two test pieces (one from each odd) at the rate of traverse of 100± 10mm per minute in accordance with IS 3400 (Part 5): 1986 or Static Dead Load
Method as given in Annex C. The individual adhesion value for consolidation test shall not be less than 30N (3.0 kgf) for each of the teat piecea (see Note
under 4.4).') |
- |
1000 |
|
- |
| CL.4.6 Mass(The mass of one pair of finished shoes of size 8 shall not exceed 750 g with an increase or decrease of 25 g for each bigger or smaller size respectively) |
- |
500 |
|
- |
| Cl.4.4 Adhesion Test(From the upper-foxing portion where it is adhered to the canvas, parallel to the waist of sole, cut a strip of length 100 mm and width 8 mm. Separate out
the plies initially by breaking the bond to a length of about 75 mm. Carry out the test on two specimens in accordance with IS 3400 (Part 5) : 1986. There
shall be no further separation within 1 minute at a load of 1 kg for each of the two specimens.) |
- |
600 |
|
- |
| Cl.4.3.8( A rubber foxing shall be fixed all round the sole and heel. The colour shall be as agreed to between the purchaser and the supplier. ) |
- |
1000 |
|
- |
| Cl.4.3.8(The foxing, not less
than 18 mm wide, shall not extend beyond the edges of the sole at the bottom) |
- |
500 |
|
- |
| Cl.4.3.5( Five pairs of eyelets shall be fitted in each
shoe. The eyelets shall be properly clenched without
any distortion. It shall properly match the colour of
the upper canvas, or as agreed to between the purchaser
and the supplier.) |
- |
500 |
|
- |
| Cl.4.3.3( The counter shall be stitched at the back, set from bottom of lining and bound flat on top edge
with white/scoured binding material cut in bias and formed as a tape. T ) |
- |
500 |
|
- |
| Cl.4.3.3(he number of stitches shall be
30 to 40 per decimetre. The counter binding shall
meet the binding of the upper at the centre top edge
of the heel.) |
- |
500 |
|
- |
| Cl.4.3.3(The edges of quarter shall be bound with
dyed cotton binding material or matching to the colour
of the upper, cut in bias and formed as a tape.) |
- |
500 |
|
- |
| Cl.'4.3.2( Back of the upper shall be reinforced with a strip of upper material when
there is a seam.') |
- |
500 |
|
- |
| CL.4.2 Shape and Design
IS 1638 : 1969(Cl 4.2.1 The shoes shall be made according to design
and pattern as agreed to between the purchaser and
the supplier. Size and fittings of the shoes shall be
in accordance with IS 1638 : 1969 unless otherwise
specified by the purchaser.) |
- |
500 |
|
- |
| Cl.4.2.2( The recommended design of canvas shoes is
shown in Fig. 1.) |
- |
500 |
|
- |
| Cl.4.1.6.2 Ageing
col 4 of Table 5.(The shoes shall be also aged at 70 ± 1°C for 168 h, on completion of which the test pieces taken from the shoes shall conform to the physical requirements
prescribed in col 4 of Table 5. ) |
- |
4000 |
|
- |
| Cl.4.1.6.2 Ageing
(None of the rubber components of the shoes shall show any sign of tackiness or crack developed after ageing, when examined visually) |
- |
1000 |
|
- |
| " CL. 5.1, Cl. 5.2, Cl. 5.2.1, Cl. 5.2.1.1(Packing and marking ") |
- |
500 |
|
- |
| 4.1.1 (Drill) (End & Picks/dm) |
- |
500 |
|
- |
| 4.1.1 (canvas )(Breaking Load ) |
- |
440 |
|
- |
| 4.1.1 (canvas )(End & Picks/dm) |
- |
500 |
|
- |
| 4.1.1.1(Colorfastness to light ) |
- |
800 |
|
- |
| 4.1.6(Elongation at break ) |
- |
440 |
|
- |
| 4.1.6(Tensile strength) |
- |
440 |
|
- |
| 4.1.6(Hardness (after accelerated )) |
- |
400 |
|
- |
| 4.1.6(Flexing resistance test) |
- |
1200 |
|
- |
| 4.1.6(Hardness ) |
- |
400 |
|
- |
| 4.1.6(Relative density) |
- |
400 |
|
- |
| Cl.4.1.6.2 Ageing
col 4 of Table 5.(The shoes shall be also aged at 70 ± 1°C for 168 h, on completion of which the test pieces taken from the shoes shall conform to the physical requirements
prescribed in col 4 of Table 5. ) |
- |
4000 |
|
- |
| Cl.4.1.6.2 Ageing
(None of the rubber components of the shoes shall show any sign of tackiness or crack developed after ageing, when examined visually) |
- |
1000 |
|
- |
| 4.1.1 Upper, Sl No. (i) of Table 1(The upper shall consist of over layer of cotton, manmade or blended
conforming' to the requirements given in Sl No. (i) of Table 1 as an overlayer and cotton drill conforming to the
requirements given in Sl No. (ii) of Table 1, as an inner layer or lining. The two fabrics shall be firmly adhered together with rubber compound. ) |
- |
500 |
|
- |
| Cl.4.1.2 Binding Material(IS 1954 : 1990)
(IS1969 : 1985)(Cotton tape NEWAR used as binding material shall conform to the requirements prescribed in col 3 of
Table 2, when tested in accordance with the methods referred to in col 4 of the table.) |
- |
500 |
|
- |
| Cl.4.3 Construction
Cl 4.3.1( The upper shall be stitched on a lock stitch machine and the number of stitches shall be 30 to
40 per dm.) |
- |
500 |
|
- |
| Cl.4.3.3( The counter shall be stitched at the back, set from bottom of lining and bound flat on top edge
with white/scoured binding material cut in bias and formed as a tape. T ) |
- |
500 |
|
- |
| Cl.4.3.3(he number of stitches shall be
30 to 40 per decimetre. The counter binding shall
meet the binding of the upper at the centre top edge
of the heel.) |
- |
500 |
|
- |
| Cl.4.3.3(The edges of quarter shall be bound with
dyed cotton binding material or matching to the colour
of the upper, cut in bias and formed as a tape.) |
- |
500 |
|
- |
| Cl.4.3.4 (The vantp shall be strengthened with a rubber
toe-cap (see Fig. 1).) |
- |
500 |
|
- |
| Cl.4.3.6( The shoes shall be free from folds, wrinkles in the upper, blisters, embedded foreign matters and
excessive surface markings. In appearance, general workmanship, finish and all other respects, not defined
in the standard, the shoes shall be similar to the
sample approved by the purchaser, if any) |
- |
500 |
|
- |
| CL.4.3.7( The soles shall be of even substance and ofone layer only.) |
- |
500 |
|
- |
| Cl.4.3.8( A rubber foxing shall be fixed all round the sole and heel. The colour shall be as agreed to between the purchaser and the supplier. ) |
- |
500 |
|
- |
| Cl.4.3.8(The foxing, not less
than 18 mm wide, shall not extend beyond the edges of the sole at the bottom) |
- |
500 |
|
- |
| Cl.4.1.1.1 Colour fastness(The dyed fabrics prescribed in 4.1.1 shall be fast todaylight and mechanical washing. Fastness to daylight
shall be of rating 4 or better, when tested in accordance with IS 686 : 1985 or IS 2454: 1985. However in case of dispute the method prescribed in IS 686 : 1985
shall be considered as referee method.) |
- |
1400 |
|
- |
| Cl.4.1.2.1
Anmex B.(Cotton, manmade or blended shall be used as binding material.'
'Coloured cotton tapes shall have fastness to day light of rating as and if agreed
to between the purchaser and the supplier when tested in accordance with IS 686 :
1985. The black tapes shall be free from sulphur dyes when tested in accordance
with Annex B.') |
- |
500 |
|
- |
| Cl.4.1.4(.Brass, steel or aluminium eyelets of 7.5 mm diameter and wall thickness 0.30 to
0.35 mm shall be used.') |
- |
500 |
|
- |
| Cl.4.1.5 Laces(
The shoes shall be provided with fabric braided laces
either matching the shade of the upper or black or The length of the lace shall be 60 ± 3 cm ) |
- |
500 |
|
- |
| Cl.4.1.5 Laces(and shallhave the breaking strength of not less than 250 N when tested between 18 cm grips in accordance with
IS 1969 : 1985, the rate of traverse of power actuated grip being 300 mm/min.) |
- |
600 |
|
- |
| Cl.4.1.5 Laces
Annex B(In case the laces are black,
the same shall pass the test for freedom from sulpher
dyes when tested in accordance with Annex B. The
two ends of the lace shall be provided with suitable
metal or plastic tips.) |
- |
400 |
|
- |
| Cl.4.1.6 Rubber Components(The rubber components shall conform to the requirements given in Table 4, when tested from finished boots.However in case it is not possible to cut the test pieces from the made up boots then 4.1.5.3 of IS
13695 : 1993 shall be followed.') |
- |
500 |
|
- |
| Cl.4.1 (Table B-3 Sl I)(Allergenic and Carcinogenic Disperse Dyes) |
- |
5600 |
|
- |
| Cl.4.1 (Table B-11)(PCP-TeCP-TriCP polychlorophenols) |
- |
2800 |
|
- |
|
02 Dec, 2028 |
- (Clause 4.1.2.1 & 4.1.2.2 - Mechanical
Laundering) |
| 1918 |
Aaditech Test and Calibration Lab LLP
| 8179926
| IS 302 : Part 2 : Sec 6 (2009) |
Safety of household and similar electrical appliances: Part 2 particular requirements: Sec 6 cooking ranges, hobs, ovens and similar appliances (First Revision) |
Their rated voltage being not more than 250 V for single-phase appliances connected between one phase and neutral, and 480 V for other appliances. |
17000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 6.0(Classification) |
- |
500 |
|
- |
| 7.0(Marking and instructions) |
- |
1000 |
|
- |
| 8.0(Protection against access to live part test) |
- |
500 |
|
- |
| 9.0(Starting of motor-operated appliances test) |
- |
0 |
|
- |
| 10.0(Power Input and current test) |
- |
500 |
|
- |
| 11.0(Heating test) |
- |
1000 |
|
- |
| 13.0(Leakage current and electric strength test) |
- |
1000 |
|
- |
| 14.0(Transient voltages) |
- |
0 |
|
- |
| 15.0(Moisture Resistance) |
- |
2000 |
|
- |
| 16.0(Leakage current and electric strength test) |
- |
1000 |
|
- |
| 17.0(Overload protection of transformers test) |
- |
0 |
|
- |
| 18.0(Endurance test) |
- |
0 |
|
- |
| 19.0(Abnormal Operations) |
- |
1000 |
|
- |
| 20.0(Stability and Mechanical Hazards) |
- |
500 |
|
- |
| 21.0(Mechanical Strength) |
- |
500 |
|
- |
| 22.0(Construction verification related tests) |
- |
500 |
|
- |
| 23.0(Internal wiring) |
- |
500 |
|
- |
| 24.0(Components) |
- |
500 |
|
- |
| 25.0(Supply connections and External Flexible Cords) |
- |
1000 |
|
- |
| 26.0(Terminal for External Conductors) |
- |
500 |
|
- |
| 27.0(Provision for Earthing) |
- |
500 |
|
- |
| 28.0(Screws and connections) |
- |
500 |
|
- |
| 29.0(Clearances and Creepage distances and solid insulation) |
- |
500 |
|
- |
| 30.0(Resistance to heat and fire) |
- |
2000 |
|
- |
| 31.0(Resistance to rusting) |
- |
1000 |
|
- |
| 32.0(Radiation, Toxicity and Similar hazards) |
- |
0 |
|
- |
| 19.11.4.1(Electrostatic discharges) |
- |
0 |
|
- |
| 19.11.4.2(Radiated fields) |
- |
0 |
|
- |
| 19.11.4.3(Fast transient bursts) |
- |
0 |
|
- |
| 19.11.4.4(Surge immunity test) |
- |
0 |
|
- |
| 19.11.4.5(Immunity to conducted discharges) |
- |
0 |
|
- |
| 19.11.4.6(Class 3 Voltage dips and interruptions) |
- |
0 |
|
- |
| 19.11.4.7(Harmonics) |
- |
0 |
|
- |
| 4(General Requirements) |
- |
0 |
|
- |
| 5(General condition for the tests) |
- |
0 |
|
- |
| 22.111(Pyrolytic self-cleaning) |
- |
0 |
|
- |
| 6.0(Classification) |
- |
0 |
|
- |
| 7.0(Marking and instructions) |
- |
0 |
|
- |
| 8.0(Protection against access to live part test) |
- |
0 |
|
- |
| 9.0(Starting of motor-operated appliances test) |
- |
0 |
|
- |
| 10.0(Power Input and current test) |
- |
0 |
|
- |
| 11.0(Heating test) |
- |
0 |
|
- |
| 13.0(Leakage current and electric strength test) |
- |
0 |
|
- |
| 14.0(Transient voltages) |
- |
0 |
|
- |
| 15.0(Moisture Resistance) |
- |
0 |
|
- |
| 16.0(Leakage current and electric strength test) |
- |
0 |
|
- |
| 17.0(Overload protection of transformers test) |
- |
0 |
|
- |
| 18.0(Endurance test) |
- |
0 |
|
- |
| 19.0(Abnormal Operations) |
- |
0 |
|
- |
| 20.0(Stability and Mechanical Hazards) |
- |
0 |
|
- |
| 21.0(Mechanical Strength) |
- |
0 |
|
- |
| 22.0(Construction verification related tests) |
- |
0 |
|
- |
| 23.0(Internal wiring) |
- |
0 |
|
- |
| 24.0(Components) |
- |
0 |
|
- |
| 25.0(Supply connections and External Flexible Cords) |
- |
0 |
|
- |
| 26.0(Terminal for External Conductors) |
- |
0 |
|
- |
| 27.0(Provision for Earthing) |
- |
0 |
|
- |
| 28.0(Screws and connections) |
- |
0 |
|
- |
| 29.0(Clearances and Creepage distances and solid insulation) |
- |
0 |
|
- |
| 30.0(Resistance to heat and fire) |
- |
0 |
|
- |
| 31.0(Resistance to rusting) |
- |
0 |
|
- |
| 32.0(Radiation, Toxicity and Similar hazards) |
- |
0 |
|
- |
| 19.11.4.1(Electrostatic discharges) |
- |
0 |
|
- |
| 19.11.4.2(Radiated fields) |
- |
0 |
|
- |
| 19.11.4.3(Fast transient bursts) |
- |
0 |
|
- |
| 19.11.4.4(Surge immunity test) |
- |
0 |
|
- |
| 19.11.4.5(Immunity to conducted discharges) |
- |
0 |
|
- |
| 19.11.4.6(Class 3 Voltage dips and interruptions) |
- |
0 |
|
- |
| 19.11.4.7(Harmonics) |
- |
0 |
|
- |
| 4(General Requirements) |
- |
0 |
|
- |
| 5(General condition for the tests) |
- |
0 |
|
- |
| 22.111(Pyrolytic self-cleaning) |
- |
0 |
|
- |
| 6.0(Classification) |
- |
0 |
|
- |
| 7.0(Marking and instructions) |
- |
0 |
|
- |
| 8.0(Protection against access to live part test) |
- |
0 |
|
- |
| 9.0(Starting of motor-operated appliances test) |
- |
0 |
|
- |
| 10.0(Power Input and current test) |
- |
0 |
|
- |
| 11.0(Heating test) |
- |
0 |
|
- |
| 13.0(Leakage current and electric strength test) |
- |
0 |
|
- |
| 14.0(Transient voltages) |
- |
0 |
|
- |
| 15.0(Moisture Resistance) |
- |
0 |
|
- |
| 16.0(Leakage current and electric strength test) |
- |
0 |
|
- |
| 17.0(Overload protection of transformers test) |
- |
0 |
|
- |
| 18.0(Endurance test) |
- |
0 |
|
- |
| 19.0(Abnormal Operations) |
- |
0 |
|
- |
| 20.0(Stability and Mechanical Hazards) |
- |
0 |
|
- |
| 21.0(Mechanical Strength) |
- |
0 |
|
- |
| 22.0(Construction verification related tests) |
- |
0 |
|
- |
| 23.0(Internal wiring) |
- |
0 |
|
- |
| 24.0(Components) |
- |
0 |
|
- |
| 25.0(Supply connections and External Flexible Cords) |
- |
0 |
|
- |
| 26.0(Terminal for External Conductors) |
- |
0 |
|
- |
| 27.0(Provision for Earthing) |
- |
0 |
|
- |
| 28.0(Screws and connections) |
- |
0 |
|
- |
| 29.0(Clearances and Creepage distances and solid insulation) |
- |
0 |
|
- |
| 30.0(Resistance to heat and fire) |
- |
0 |
|
- |
| 31.0(Resistance to rusting) |
- |
0 |
|
- |
| 32.0(Radiation, Toxicity and Similar hazards) |
- |
0 |
|
- |
| 19.11.4.1(Electrostatic discharges) |
- |
0 |
|
- |
| 19.11.4.2(Radiated fields) |
- |
0 |
|
- |
| 19.11.4.3(Fast transient bursts) |
- |
0 |
|
- |
| 19.11.4.4(Surge immunity test) |
- |
0 |
|
- |
| 19.11.4.5(Immunity to conducted discharges) |
- |
0 |
|
- |
| 19.11.4.6(Class 3 Voltage dips and interruptions) |
- |
0 |
|
- |
| 19.11.4.7(Harmonics) |
- |
0 |
|
- |
| 4(General Requirements) |
- |
0 |
|
- |
| 5(General condition for the tests) |
- |
0 |
|
- |
| 22.111(Pyrolytic self-cleaning) |
- |
0 |
|
- |
| 6.0(Classification) |
- |
0 |
|
- |
| 7.0(Marking and instructions) |
- |
0 |
|
- |
| 8.0(Protection against access to live part test) |
- |
0 |
|
- |
| 9.0(Starting of motor-operated appliances test) |
- |
0 |
|
- |
| 10.0(Power Input and current test) |
- |
0 |
|
- |
| 11.0(Heating test) |
- |
0 |
|
- |
| 13.0(Leakage current and electric strength test) |
- |
0 |
|
- |
| 14.0(Transient voltages) |
- |
0 |
|
- |
| 15.0(Moisture Resistance) |
- |
0 |
|
- |
| 16.0(Leakage current and electric strength test) |
- |
0 |
|
- |
| 17.0(Overload protection of transformers test) |
- |
0 |
|
- |
| 18.0(Endurance test) |
- |
0 |
|
- |
| 19.0(Abnormal Operations) |
- |
0 |
|
- |
| 20.0(Stability and Mechanical Hazards) |
- |
0 |
|
- |
| 21.0(Mechanical Strength) |
- |
0 |
|
- |
| 22.0(Construction verification related tests) |
- |
0 |
|
- |
| 23.0(Internal wiring) |
- |
0 |
|
- |
| 24.0(Components) |
- |
0 |
|
- |
| 25.0(Supply connections and External Flexible Cords) |
- |
0 |
|
- |
| 26.0(Terminal for External Conductors) |
- |
0 |
|
- |
| 27.0(Provision for Earthing) |
- |
0 |
|
- |
| 28.0(Screws and connections) |
- |
0 |
|
- |
| 29.0(Clearances and Creepage distances and solid insulation) |
- |
0 |
|
- |
| 30.0(Resistance to heat and fire) |
- |
0 |
|
- |
| 31.0(Resistance to rusting) |
- |
0 |
|
- |
| 32.0(Radiation, Toxicity and Similar hazards) |
- |
0 |
|
- |
| 19.11.4.1(Electrostatic discharges) |
- |
0 |
|
- |
| 19.11.4.2(Radiated fields) |
- |
0 |
|
- |
| 19.11.4.3(Fast transient bursts) |
- |
0 |
|
- |
| 19.11.4.4(Surge immunity test) |
- |
0 |
|
- |
| 19.11.4.5(Immunity to conducted discharges) |
- |
0 |
|
- |
| 19.11.4.6(Class 3 Voltage dips and interruptions) |
- |
0 |
|
- |
| 19.11.4.7(Harmonics) |
- |
0 |
|
- |
| 4(General Requirements) |
- |
0 |
|
- |
| 5(General condition for the tests) |
- |
0 |
|
- |
| 22.111(Pyrolytic self-cleaning) |
- |
0 |
|
- |
|
28 Aug, 2027 |
- Included w.e.f. 21.08.2025
Exclusion: "19.11.4.1 (Electrostatic discharges)
19.11.4.2 (Radiated fields)
19.11.4.3 (Fast transient bursts)
19.11.4.4 (Surge immunity test)
19.11.4.5 (Immunity to conducted discharges)
19.11.4.6 (Class 3 Voltage dips and interruptions)
19.11.4.7 (Harmonics)
32.0 (Radiation, Toxicity and Similar hazards)
" |
| 1919 |
Atckon Laboratories LLP, Bahadurgarh
| 8186436
| IS 1117 (2018) |
Laboratory glassware - Single - Volume pipettes (Second Revision) |
all |
13500 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 6.1.1&3(Marking) |
- |
500 |
|
- |
| 3(Class of Accuracy) |
- |
500 |
|
- |
| 4.1(Nominal capacities) |
- |
500 |
|
- |
| 4.2(Accuracy) |
- |
500 |
|
- |
| 5.1(Material) |
- |
500 |
|
- |
| 5.1(Material) |
- |
500 |
|
- |
| 5.1.1(Limit of Alkalinity) |
- |
500 |
|
- |
| 5.2(Pattern of Pipette) |
- |
500 |
|
- |
| 5.3(Workmanship & Finish) |
- |
500 |
|
- |
| 5.4(i) Distance of graduation line from top of pipette.) |
- |
500 |
|
- |
| 5.4(ii) Distance from graduation line to top of bulb(pattern 2)) |
- |
500 |
|
- |
| 5.4(iii)Distance from graduation line to tip of jet (Pattern 1)) |
- |
500 |
|
- |
| 5.4(iv) Wall thickness) |
- |
500 |
|
- |
| 5.4(a) pattern 2 pipette of 1 and 2ml ) |
- |
500 |
|
- |
| 5.4(b) Other pipettes) |
- |
500 |
|
- |
| 5.4(v) Dia. of safety bulb (if provided )) |
- |
500 |
|
- |
| 5.4(vi)Distance from top of pipette to bottom of safety bulb ) |
- |
500 |
|
- |
| 5.4(vii) Overall length, L) |
- |
500 |
|
- |
| 5.4(viii) Length of suction tube, L1 ) |
- |
500 |
|
- |
| 5.4(ix) Length of delivery tube, L2 ) |
- |
500 |
|
- |
| 5.4(x) Internal dia. of suction tube D1 ) |
- |
500 |
|
- |
| 5.4(xi) External dia. of bulb D2 ) |
- |
500 |
|
- |
| 5.4(xii) External dia. of delivery tube D3 ) |
- |
500 |
|
- |
| 5.5(Delivery Time) |
- |
500 |
|
- |
| 5.5(Delivery Time) |
- |
500 |
|
- |
| 5.6&7(Graduation line & Visibility ) |
- |
500 |
|
- |
| 6.1.2(Marking) |
- |
500 |
|
- |
| 6.1.1&3(Marking) |
- |
500 |
|
- |
| 3(Class of Accuracy) |
- |
500 |
|
- |
| 4.1(Nominal capacities) |
- |
500 |
|
- |
| 4.2(Accuracy) |
- |
500 |
|
- |
| 5.1(Material) |
- |
500 |
|
- |
| 5.1(Material) |
- |
500 |
|
- |
| 5.1.1(Limit of Alkalinity) |
- |
500 |
|
- |
| 5.2(Pattern of Pipette) |
- |
500 |
|
- |
| 5.3(Workmanship & Finish) |
- |
500 |
|
- |
| 5.4(i) Distance of graduation line from top of pipette.) |
- |
500 |
|
- |
| 5.4(ii) Distance from graduation line to top of bulb(pattern 2)) |
- |
500 |
|
- |
| 5.4(iii)Distance from graduation line to tip of jet (Pattern 1)) |
- |
500 |
|
- |
| 5.4(iv) Wall thickness) |
- |
500 |
|
- |
| 5.4(a) pattern 2 pipette of 1 and 2ml ) |
- |
500 |
|
- |
| 5.4(b) Other pipettes) |
- |
500 |
|
- |
| 5.4(v) Dia. of safety bulb (if provided )) |
- |
500 |
|
- |
| 5.4(vi)Distance from top of pipette to bottom of safety bulb ) |
- |
500 |
|
- |
| 5.4(vii) Overall length, L) |
- |
500 |
|
- |
| 5.4(viii) Length of suction tube, L1 ) |
- |
500 |
|
- |
| 5.4(ix) Length of delivery tube, L2 ) |
- |
500 |
|
- |
| 5.4(x) Internal dia. of suction tube D1 ) |
- |
500 |
|
- |
| 5.4(xi) External dia. of bulb D2 ) |
- |
500 |
|
- |
| 5.4(xii) External dia. of delivery tube D3 ) |
- |
500 |
|
- |
| 5.5(Delivery Time) |
- |
500 |
|
- |
| 5.5(Delivery Time) |
- |
500 |
|
- |
| 5.6&7(Graduation line & Visibility ) |
- |
500 |
|
- |
| 6.1.2(Marking) |
- |
500 |
|
- |
| 6.1.1&3(Marking) |
- |
500 |
|
- |
| 3(Class of Accuracy) |
- |
500 |
|
- |
| 4.1(Nominal capacities) |
- |
500 |
|
- |
| 4.2(Accuracy) |
- |
500 |
|
- |
| 5.1(Material) |
- |
500 |
|
- |
| 5.1(Material) |
- |
500 |
|
- |
| 5.1.1(Limit of Alkalinity) |
- |
500 |
|
- |
| 5.2(Pattern of Pipette) |
- |
500 |
|
- |
| 5.3(Workmanship & Finish) |
- |
500 |
|
- |
| 5.4(i) Distance of graduation line from top of pipette.) |
- |
500 |
|
- |
| 5.4(ii) Distance from graduation line to top of bulb(pattern 2)) |
- |
500 |
|
- |
| 5.4(iii)Distance from graduation line to tip of jet (Pattern 1)) |
- |
500 |
|
- |
| 5.4(iv) Wall thickness) |
- |
500 |
|
- |
| 5.4(a) pattern 2 pipette of 1 and 2ml ) |
- |
500 |
|
- |
| 5.4(b) Other pipettes) |
- |
500 |
|
- |
| 5.4(v) Dia. of safety bulb (if provided )) |
- |
500 |
|
- |
| 5.4(vi)Distance from top of pipette to bottom of safety bulb ) |
- |
500 |
|
- |
| 5.4(vii) Overall length, L) |
- |
500 |
|
- |
| 5.4(viii) Length of suction tube, L1 ) |
- |
500 |
|
- |
| 5.4(ix) Length of delivery tube, L2 ) |
- |
500 |
|
- |
| 5.4(x) Internal dia. of suction tube D1 ) |
- |
500 |
|
- |
| 5.4(xi) External dia. of bulb D2 ) |
- |
500 |
|
- |
| 5.4(xii) External dia. of delivery tube D3 ) |
- |
500 |
|
- |
| 5.5(Delivery Time) |
- |
500 |
|
- |
| 5.5(Delivery Time) |
- |
500 |
|
- |
| 5.6&7(Graduation line & Visibility ) |
- |
500 |
|
- |
| 6.1.2(Marking) |
- |
500 |
|
- |
| 4.1(unit of volume) |
- |
500 |
|
- |
| 4.2(delivery volume) |
- |
500 |
|
- |
| 4.3(reference temperature) |
- |
500 |
|
- |
| 5.1(Types and Classes of accuracy) |
- |
500 |
|
- |
| 5.2(Types of single- volume pipette) |
- |
500 |
|
- |
| Clause- 6.0(Maximum Permissible error) |
- |
500 |
|
- |
| 7.1(Material) |
- |
500 |
|
- |
| 7.2(Shape) |
- |
500 |
|
- |
| 7.3(Bulb) |
- |
500 |
|
- |
| 7.4(Dimensions) |
- |
500 |
|
- |
| 7.5(Top of Pipette) |
- |
500 |
|
- |
| 7.6(Delivery Jet) |
- |
500 |
|
- |
| 7.7(Delivery Time) |
- |
500 |
|
- |
| 7.8(Waiting Time) |
- |
500 |
|
- |
| Clause- 8.0(Graduation Line) |
- |
500 |
|
- |
| Clause- 9.0(Setting of the Meniscus) |
- |
500 |
|
- |
| Clause-10.0(Marking) |
- |
500 |
|
- |
| Cl-7.4, Table-2 (i)(Overall length) |
- |
500 |
|
- |
| Cl-7.4, Table-2 (ii)(Internal diameter at the graduation line) |
- |
500 |
|
- |
| Cl-7.4, Table-2 (iii)(Length of suction tube⎯ valid only for bulb pattern pipettes) |
- |
500 |
|
- |
| Cl-7.4, Table-2 (iv)(Length of delivery tube ⎯ valid only for bulb pattern pipettes) |
- |
500 |
|
- |
| Cl-7.4, Table-2 (v)(External diameter of delivery tube
⎯ valid only for bulb pattern pipettes) |
- |
500 |
|
- |
| Cl-7.4, Table-2 (vi)(External diameter of bulb ⎯ valid only for bulb pattern pipettes) |
- |
500 |
|
- |
| Cl-7.4, Table-2 (vii)(External diameter of tube
⎯ valid only for straight pattern pipettes) |
- |
500 |
|
- |
| Cl-7.4, Table-3 (i)(Distance of graduation line from top of pipette (one-mark pipettes)) |
- |
500 |
|
- |
| Cl-7.4, Table-3 (ii)(Distance from graduation line to tip of jet (one-mark pipettes)
⎯ valid only for straight pattern pipettes) |
- |
500 |
|
- |
| Cl-7.4, Table-3 (iii)(Distance from graduation line to tip of jet (one-mark pipettes)
⎯ valid only for straight pattern pipettes) |
- |
500 |
|
- |
| Cl-7.4, Table-3 (iv)(Wall thickness (one-mark pipettes)
⎯ bulb pattern pipettes) |
- |
500 |
|
- |
| Cl-7.4, Table-3 (v)(Wall thickness (one-mark pipettes)
⎯ straight pattern pipettes) |
- |
500 |
|
- |
| Cl-7.4, Table-4 (i)(Distance of upper graduation line from top of pipette (two-mark pipettes)) |
- |
500 |
|
- |
| Cl-7.4, Table-4 (ii)(Distance of upper graduation line from top of pipette (two-mark pipettes)) |
- |
500 |
|
- |
| Cl-7.4, Table-4 (iii)(Distance from upper graduation line to tip of jet (two-mark pipettes)
⎯ valid only for straight pattern pipettes) |
- |
500 |
|
- |
| Cl-7.4, Table-4 (iv)(Distance from lower graduation line to bottom of bulb (two-mark pipettes)) |
- |
500 |
|
- |
| Cl-7.4, Table-4 (v)(Distance from lower graduation line to tip of jet (two-mark pipettes)) |
- |
500 |
|
- |
| Cl-7.4, Table-4 (vi)(Wall thickness (two-mark pipettes)
⎯ bulb pattern pipettes) |
- |
500 |
|
- |
| Cl-7.4, Table-4 (vii)(Wall thickness (two-mark pipettes)
⎯ straight pattern pipettes) |
- |
500 |
|
- |
| Cl-11(Visibility of graduation lines, figures and inscriptions) |
- |
500 |
|
- |
| Cl-12(Colour coding) |
- |
500 |
|
- |
| Cl-12(Colour coding) |
- |
500 |
|
- |
|
19 Jun, 2028 |
- Included w.e.f 18.08.2025 |
| 1920 |
Sleen India Biz venture Private Limited, Agra
| 9139736
| IS 4215 (1983) |
Specification for ring type needle bearings (First Revision) |
- |
14250 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 2(Types ) |
- |
250 |
|
- |
| 3(Material) |
- |
4000 |
|
- |
| 4(Hardness) |
- |
1500 |
|
- |
| 5.1(Dimensions for radial, without inner rings ) |
- |
3000 |
|
- |
| 5.2(Dimensions for radial, with inner rings ) |
- |
0 |
|
Complete Test price for cl.5 dimension is 3000/-. |
| 5.3(Dimensions for bearing without inner rings) |
- |
0 |
|
Complete Test price for cl.5 dimension is 3000/-. |
| 5.4(Dimensions for bearing with inner rings ) |
- |
0 |
|
Complete Test price for cl.5 dimension is 3000/-. |
| 5.5(Dimensions for needle bearings without outer rings) |
- |
0 |
|
Complete Test price for cl.5 dimension is 3000/-. |
| 5.6(Dimensions for needle thrust bearings) |
- |
0 |
|
Complete Test price for cl.5 dimension is 3000/-. |
| 5.7(Dimensions for combined needle bearings) |
- |
0 |
|
Complete Test price for cl.5 dimension is 3000/-. |
| 5.8(Dimensional tolerances for needle bearing ) |
- |
0 |
|
Complete Test price for cl.5 dimension is 3000/-. |
| 6(Designation ) |
- |
250 |
|
- |
| 7(Workmanship and Finish) |
- |
2500 |
|
- |
| 8(Packing and Marking) |
- |
250 |
|
- |
|
15 May, 2027 |