1 |
IS 16169 (2014) |
Utility - Interconnected photovoltaic inverters - Test procedure of islanding prevention measures |
-
|
300000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
6, (Elec)(Test for single or multi-phase inverter) |
- |
3500 |
|
- |
Annex A(Islanding as it applies to PV systems) |
- |
2000 |
|
- |
Annex B(Test for independent islanding device) |
- |
4000 |
|
- |
6 to 6.2, (Elec)(Test for single or multi-phase inverter to Pass/fail criteria) |
- |
290000 |
|
- |
7, (Elec)(Documentation) |
- |
500 |
|
- |
Annex B, (Elec)(Test for independent islanding device) |
- |
4000 |
|
- |
Annex A, (Elec)(Islanding as it applies to PV systems) |
- |
2000 |
|
- |
7(Documentation) |
- |
500 |
|
- |
6 to 6.2(Test for single or multi-phase inverter to Pass/fail criteria) |
- |
290000 |
|
- |
6(Test for single or multi-phase inverter) |
- |
3500 |
|
- |
|
Complete
|
|
23 Jun, 2025 |
- |
2 |
IS 16169 (2019) |
Utility - Interconnected photovoltaic inverters - Test procedure of islanding prevention measures (First Revision) |
-
|
300000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
6(Test for single or multi-phase inverter) |
- |
3000 |
|
- |
Annex A(Islanding as it applies to PV systems) |
- |
2000 |
|
- |
Annex B(Test for independent islanding device) |
- |
4000 |
|
- |
6 to 6.2(Test for single or multi-phase inverter to Pass/fail criteria) |
- |
290000 |
|
- |
7(Documentation) |
- |
500 |
|
- |
4(Testing circuit) |
- |
200 |
|
- |
5(Testing equipment) |
- |
100 |
|
- |
Annex C(Gate blocking signal) |
- |
200 |
|
- |
|
Complete
|
|
23 Jun, 2025 |
- |
3 |
IS/IEC 61730 : PART 2 (2019) |
Photovoltaic (PV) module safety qualification: Part 2 requirements for testing (First Revision) |
-
|
1500000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
4.1(General) |
- |
5000 |
|
- |
4.2(Thermal Cycling (TC50)) |
- |
7857 |
|
- |
4.2(Thermal Cycling (TC200)) |
- |
7857 |
|
- |
4.2(Humidity Freeze (HF10)) |
- |
7857 |
|
- |
4.2(Damp Heat (DH1000)) |
- |
7857 |
|
- |
4.2(UV Preconditioning) |
- |
7857 |
|
- |
4.2(Cold Conditioning) |
- |
7857 |
|
- |
4.2(Dry Hot Conditioning) |
- |
7857 |
|
- |
4.3(Visual inspection) |
- |
11428 |
|
- |
4.3(Performance at STC) |
- |
11428 |
|
- |
4.3(Maximum power determination) |
- |
11428 |
|
- |
4.3(Insulation thickness) |
- |
11428 |
|
- |
4.3(Durability of markings) |
- |
11428 |
|
- |
4.3(Sharp edge test) |
- |
11428 |
|
- |
4.3(Bypass diode functionality test) |
- |
11428 |
|
- |
4.4(Accessibility test) |
- |
2857 |
|
- |
4.4(Cut susceptibility test) |
- |
2857 |
|
- |
4.4(Continuity test for equipotential bonding) |
- |
2857 |
|
- |
4.4(Impulse voltage test) |
- |
2857 |
|
- |
4.4(Insulation test) |
- |
2857 |
|
- |
4.4(Wet leakage current test) |
- |
2857 |
|
- |
4.4(Robustness of terminations test) |
- |
2857 |
|
- |
4.5(Temperature test) |
- |
1333 |
|
- |
4.5(Hot-spot endurance test) |
- |
1333 |
|
- |
4.5(Fire test) |
- |
1333 |
|
- |
4.5(Ignitability test) |
- |
1333 |
|
- |
4.5(Bypass diode thermal test) |
- |
1333 |
|
- |
4.5(Reverse current overload test) |
- |
1333 |
|
- |
4.6(Module breakage test) |
- |
2142 |
|
- |
4.6(Screw connection test) |
- |
2142 |
|
- |
4.6(Mechanical load test) |
- |
2142 |
|
- |
4.6(Peel test) |
- |
2142 |
|
- |
4.6(Lap shear strength test) |
- |
2142 |
|
- |
4.6(Materials creep test) |
- |
2142 |
|
- |
4.6(Robustness of terminations test) |
- |
2142 |
|
- |
10.2
IS/IEC 61730-2( Visual inspection MST01) |
- |
10000 |
|
- |
10.3
IS/IEC 61730-2(Performance at STC MST 02) |
- |
80000 |
|
- |
10.4
IS/IEC 61730-2(Maximum power determination MST 03) |
- |
30000 |
|
- |
10.5
IS/IEC 61730-2(Insulation thickness test MST 04) |
- |
10000 |
|
- |
10.6
IS/IEC 61730-2(Durability of marking MST 05) |
- |
10000 |
|
- |
10.7
IS/IEC 61730-2(Sharp edge test MST 06) |
- |
10000 |
|
- |
10.8
IS/IEC 61730-2(Bypass diode functionality test MST 07) |
- |
10000 |
|
- |
10.9
IS/IEC 61730-2(Accessibility test MST 11) |
- |
20000 |
|
- |
10.10
IS/IEC 61730-2(Cut susceptibility test MST 12) |
- |
10000 |
|
- |
10.11
IS/IEC 61730-2(Continuity test of equipotential bonding MST 13) |
- |
20000 |
|
- |
10.12
IS/IEC 61730-2(Impulse voltage test MST 14) |
- |
20000 |
|
- |
10.13
IS/IEC 61730-2( Insulation test MST 16) |
- |
10000 |
|
- |
10.14
IS/IEC 61730-2( Wet leakage current test MST 17) |
- |
20000 |
|
- |
10.15
IS/IEC 61730-2( Temperature test MST 21) |
- |
35000 |
|
- |
10.16
IS/IEC 61730-2(Hot-spot endurance test MST 22) |
- |
35000 |
|
- |
10.17
IS/IEC 61730-2( Fire test MST 23) |
- |
70000 |
|
- |
10.18
IS/IEC 61730-2(Ignitability test MST 24) |
- |
15000 |
|
- |
10.19
IS/IEC 61730-2( Bypass diode thermal test MST 25) |
- |
25000 |
|
- |
10.20
IS/IEC 61730-2( Reverse current overload test MST 25) |
- |
25000 |
|
- |
10.21
IS/IEC 61730-2( Module breakage test MST 32) |
- |
25000 |
|
- |
10.22
IS/IEC 61730-2(Screw connections test MST 33) |
- |
20000 |
|
- |
10.23
IS/IEC 61730-2( Static Mechanical load test MST 34) |
- |
30000 |
|
- |
10.24
IS/IEC 61730-2( Peel test MST 35) |
- |
80000 |
|
- |
10.25
IS/IEC 61730-2( Lap shear strength test MST 36) |
- |
50000 |
|
- |
10.26
IS/IEC 61730-2(Materials creep test MST 37) |
- |
20000 |
|
- |
10.27
IS/IEC 61730-2( Robutness of terminations test MST 42) |
- |
20000 |
|
- |
10.28
IS/IEC 61730-2(Thermal cycling test MST 51) |
- |
80000 |
|
- |
10.29
IS/IEC 61730-2( Humidity-freeze test MST 52) |
- |
80000 |
|
- |
10.30
IS/IEC 61730-2( Damp heat test MST 53) |
- |
80000 |
|
- |
10.31
IS/IEC 61730-2(UV test MST 54) |
- |
30000 |
|
- |
10.32
IS/IEC 61730-2( Cold conditioning MST 55) |
- |
80000 |
|
- |
10.33
IS/IEC 61730-2( Dry heat conditioning MST 56) |
- |
80000 |
|
- |
CL. 4,4.1(61730-2) |
- |
5000 |
|
- |
CL. 4.2, 10.27, 10.28, 10.29, 10.30, 10.31, 10.32, 10.32.1, 10.32.2, 10.32.3, 10.32.4(61730-2) |
- |
55000 |
|
- |
CL. 4.3(61730-2) |
- |
80000 |
|
- |
CL. 4.4(61730-2) |
- |
20000 |
|
- |
CL. 4.5(61730-2) |
- |
80000 |
|
- |
CL. 4.6(61730-2) |
- |
15000 |
|
- |
CL. 5(Table 6)(61730-2) |
- |
15000 |
|
- |
CL. 7(61730-2) |
- |
10000 |
|
- |
CL. 8(61730-2) |
- |
10000 |
|
- |
CL. 9(61730-2) |
- |
10000 |
|
- |
CL. 10, 10.1(61730-2) |
- |
10000 |
|
- |
CL. 10.2, 10.2.1, 10.2.2, 10.2.3(61730-2) |
- |
10000 |
|
- |
CL. 10.3, 10.3.1, 10.3.2, 10.3.3(61730-2) |
- |
80000 |
|
- |
CL. 10.4, 10.4.1, 10.4.2, 10.4.3(61730-2) |
- |
30000 |
|
- |
CL. 10.5, 10.5.1, 10.5.2, 10.5.3(61730-2) |
- |
10000 |
|
- |
CL. 10.6(61730-2) |
- |
10000 |
|
- |
CL. 10.7(61730-2) |
- |
10000 |
|
- |
CL. 10.8,10.8.1,10.8.2,10.8.3(61730-2) |
- |
10000 |
|
- |
CL. 10.9, 10.9.1, 10.9.2, 10.9.3,10.9.4,10.9.5(61730-2) |
- |
20000 |
|
- |
CL. 10.10, 10.10.1, 10.10.2, 10.10.3, 10.10.4, 10.10.5(61730-2) |
- |
10000 |
|
- |
CL. 10.11, 10.11.1, 10.11.2, 10.11.3, 10.11.4, 10.11.5(61730-2) |
- |
20000 |
|
- |
CL. 10.12, 10.12.1, 10.12.2, 10.12.3, 10.12.4, 10.12.5(61730-2) |
- |
20000 |
|
- |
CL. 10.13, 10.13.1, 10.13.2, 10.13.3(61730-2) |
- |
10000 |
|
- |
CL. 10.14(61730-2) |
- |
20000 |
|
- |
CL. 10.15, 10.15.1, 10.15.2, 10.15.2.1, 10.15.2.2, 10.15.3, 10.15.3.1, 10.15.3.2, 10.15.4(61730-2) |
- |
35000 |
|
- |
CL. 10.16(61730-2) |
- |
35000 |
|
- |
CL. 10.17, 10.17.1(61730-2) |
- |
70000 |
|
- |
CL. 10.18, 10.18.1, 10.18.2, 10.18.2.1,10.18.2.2, 10.18.2.3, 10.18.2.4, 10.18.3, 10.18.3.1, 10.18.3.2,10.18.3.3, 10.18.4, 10.18.5, 10.18.5.1, 10.18.5.2, 10.18.5.3, 10.18.6, 10.18.7, 10.18.8(61730-2) |
- |
15000 |
|
- |
CL. 10.19(61730-2) |
- |
25000 |
|
- |
CL. 10.20, 10.20.1, 10.20.2, 10.20.3(61730-2) |
- |
25000 |
|
- |
CL. 10.21, 10.21.1, 10.21.2, 10.21.3, 10.21.4(61730-2) |
- |
25000 |
|
- |
CL. 10.22, 10.22.1, 10.22.1.1, 10.22.1.2, 10.22.2, 10.22.2.1, 10.22.2.2(61730-2) |
- |
20000 |
|
- |
CL. 10.23, 10.23.1(61730-2) |
- |
30000 |
|
- |
CL. 10.24, 10.24.1, 10.24.2 , 10.24.3,10.24.4 , 10.24.5(61730-2) |
- |
80000 |
|
- |
CL. 10.25, 10.25.1, 10.25.2 , 10.25.3 , 10.25.4 , 10.25.5(61730-2) |
- |
50000 |
|
- |
CL 10.26, 10.26.1, 10.26.2, 10.26.3 , 10.26.4, 10.26.5(61730-2) |
- |
20000 |
|
- |
CL 10.27(61730-2) |
- |
20000 |
|
- |
CL 10.28(61730-2) |
- |
80000 |
|
- |
CL 10.28(61730-2) |
- |
80000 |
|
- |
CL 10.30(61730-2) |
- |
80000 |
|
- |
CL 10.31(61730-2) |
- |
30000 |
|
- |
CL 10.32, 10.32.1, 10.32.2, 10.32.3, 10.32.4(61730-2) |
- |
80000 |
|
- |
CL 10.33, 10.33.1, 10.33.2, 10.33.3, 10.33.4(61730-2) |
- |
80000 |
|
- |
Annexure B.1, B.2,B.2.1,B.2.2, B.2.3,B.3(61730-2) |
- |
40000 |
|
- |
Annexure A.1, A.2,A.3,A.4,A.5,A.6(61730-2) |
- |
10000 |
|
- |
|
Complete
|
|
23 Jun, 2025 |
- |
4 |
IS/IEC 62368 : Part 1 (2018) |
Audio / Video, Information and Communication Technology Equipment Part 1 Safety Requirements ( First Revision ) |
-
|
85000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
Cl. 4, 4.1, 4.1.1, 4.1.2, 4.1.3, 4.1.4, 4.1.5, 4.1.6, 4.1.7, 4.1.8, 4.1.9,4.1.10, 4.1.11,4.1.12, 4.1.13, 4.1.14,4.1.15(General Requirements) |
- |
500 |
|
- |
Cl. 4.2, 4.2.1, 4.2.2, 4.2.3, 4.2.4(Energy source classifications) |
- |
1000 |
|
- |
Cl. No. 4.3 ,4.4,4.5, 4.6,4.7,4.8,4.9,4.10 with all sub clauses(Protection against energy sources) |
- |
500 |
|
- |
Cl. No. 5,5.1,5.2,5.3,5.4,5.5,5.6,5.7,5.8 with all sub clauses(Electrically-caused injury) |
- |
2000 |
|
- |
Cl No. 6,6.1,6.2,6.3,6.4,6.5,6.6 with all sub clause(Electrically-caused fire) |
- |
2000 |
|
- |
Cl. 7, 7.1, 7.2, 7.3, 7.4, 7.5, 7.6(Injury caused by hazardous substances) |
- |
4000 |
|
- |
Cl. 8,8.1,8.2,8.3,8.4,8.5,8.6,8.7,8.8,8.9,8.10,8.11,8.12 with all sub clause(Mechanically-caused injury) |
- |
2000 |
|
- |
Cl. 9, 9.1, 9.2, 9.2.1,9.2.2, 9.2.3, 9.3, 9.3.1, 9.3.2, 9.4, 9.5, 9.5.1, 9.5.2, 9.6, 9.6.1, 9.6.2, 9.6.3(Thermal burn injury) |
- |
3000 |
|
- |
Annex. B, B.1, B.1.1, B.1.2, B.1.3, B.1.4, B.1.5,B.2,B.2.1, B.2.2, B.2.3, B.2.4, B.2.5, B.2.6, B.2.6.1, B.2.6.2, B.2.6.3, B.2.7, B.3, B.3.1, B.3.2, B.3.3, B.3.4, B.3.5, B.3.6, B.3.7, B.3.8, B.4, B.4.1, B.4.2, B.4.3, B.4.3.1, B.4.3.2,B.4.4, B.4.4.1, B.4.4.(Normal operating condition tests, abnormal operating condition tests and single fault condition tests) |
- |
4000 |
|
- |
Annex. D, D.1, D.2, D.3(Test Generators) |
- |
6000 |
|
- |
Annex E, E.1, E.2, E.3(Test conditions) |
- |
3000 |
|
- |
Annex. F, F.1, F.2, F2.1, F.2.2,F2.3,F.3, F.3.1, F.3.2, F.3.2.1,F.3.2.2, F.3.3,F.3.3.1, F.3.3.2,F.3.3.3, F.3.3.4, F.3.3.5, F.3.3.6,F.3.3.7, F.3.3.8, F.3.4, F.3.5, F.3.5.1,F.3.5.2, F.3.5.3, F.3.5.4, F.3.5.5,F.3.5.6, F.3.5.7,F.3.6, F.3.6.1, F.3.6.1.1, F.3.6(Equipment markings, instructions, and instructional safeguards) |
- |
4000 |
|
- |
Annex. G, G.1, G.1.1, G.1.2, G.1.3, G.2, G.2.1, G.2.2, G.2.3, G.2.4, G.3, G.3.1, G.3.1.1, G.3.1.2, G.3.2, G.3.2.1,G.3.2.2, G.3.3,G.3.4, G.3.5, G.3.5.1, G.3.5.2, G.4, G.4.1, G.4.2, G.4.3, G.5, G.5.1, G.5.1.1, G.5.1.2,G.5.1.3,G.5.2,G.5.2.1, G.5.2.2, G.5.2.3(Components) |
- |
4000 |
|
- |
Annex I(Overvoltage categories) |
- |
4000 |
|
- |
Annex. J, J.1, J.2, J.2.1, J.2.2, J.2.2.1, J.2.2.1.1, J.2.2.1.2, J.2.2.1.3, J.2.2.2, J.2.3, J.2.4, J.2.5, J.3, J.3.1, J.3.2, J.3.3(Insulated winding wires for use without interleaved insulation) |
- |
4000 |
|
- |
Annex. K, K.1, K.1.1, K.1.2, K.2, K.3, K.4, K.5, K.5.1, K.5.2, K.6, K.6.1, K.6.2, K.7, K.7.1, K.7.2, K.7.3, K.7.4(Safety Interlocks) |
- |
5000 |
|
- |
Annex. L, L.1, L.2, L.3, L.4, L.5, L.6, L.7, L.8, L.9,(Disconnect devices) |
- |
1000 |
|
- |
Annex. M, M.1, M.2, M.2.1, M.2.2, M.3, M.3.1, M.3.2, M.3.3, M.4, M.4.1, M.4.2,M.4.2.1, M.4.2.2,M.4.3, M.4.4,M.4.4.1, M.4.4.2,M.4.4.3, M.4.4.4, M.4.4.5, M.4.4.6, M.5, M.5.1, M.5.2, M.6, M.6.1, M.6.2, M.7, M.7.1, M.7.2, M.7.3, M.7.3.1,M.7.3.2, M.7.3.3, M.7.(Equipment containing batteries and their protection circuits) |
- |
2000 |
|
- |
Annex. N(Electrochemical potentials) |
- |
2000 |
|
- |
Annex. O(Measurement of creepage distances and clearances) |
- |
3000 |
|
- |
Annex. P, P.1, P.2, P.2.1, P.2.2, P.2.3, P.2.3.1, P.2.3.2, P.3, P.3.1, P.3.2, P.3.3, P.3.4, P.4, P.4.1, P.4.2(Safeguards against conductive objects) |
- |
2000 |
|
- |
Annex. Q, Q.1, Q.1.1, Q.1.2, Q.2(Circuits intended for interconnection with building wiring) |
- |
2000 |
|
- |
Annex. R, R.1, R.2, R.3, R.4(Limited short-circuit test) |
- |
5000 |
|
- |
Annex. S, S.1, S.2, S.3, S.3.1, S.3.2, S.4, S.5(Tests for resistance to heat and fire) |
- |
5000 |
|
- |
Annex. T, T.1, T.2, T.3, T.4, T.5, T.6, T.7, T.8, T.9, T.10, T.11(Mechanical strength tests) |
- |
8000 |
|
- |
Annex. V, V.1, V.1.1, V.1.2, V.1.3, V.1.4, V.1.5, V.1.6, V.2(Determination of accessible parts) |
- |
4000 |
|
- |
Annex. X(Alternative method for determining clearances for insulation in circuits connected to an AC mains not exceeding 420V peak (300V rms)) |
- |
1000 |
|
- |
Annex. Y, Y.1, Y.2, Y.3, Y.3.1, Y.3.2, Y.3.3, Y.3.4, Y.3.5, Y.4, Y.4.1 Y.4.2, Y.4.3, Y.4.4, Y.4.5, Y.5, Y.5.1, Y.5.2, Y.5.3, Y.5.4, Y.5.5, Y.5.5.1, Y.5.5.2, Y.5.5.3, Y.6, Y.6.1, Y.6.2(Construction requirements for outdoor enclosure) |
- |
1000 |
|
- |
|
Complete
|
|
23 Jun, 2025 |
- |
5 |
IS 6290 (1986) |
Specification for steam irons (First Revision) |
-
|
40000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
Cl. 5,5.1,5.2(6290) |
- |
250 |
|
- |
Cl.6,6.1(6290) |
- |
250 |
|
- |
Cl.7,7.1,7.12,7.14,7.101,7.102(6290) |
- |
500 |
|
- |
CL 8(6290) |
- |
500 |
|
- |
Cl.9(6290) |
- |
500 |
|
- |
CL 10(6290) |
- |
500 |
|
- |
CL 11(6290) |
- |
1500 |
|
- |
CL 12(6290) |
- |
500 |
|
- |
CL 13(6290) |
- |
800 |
|
- |
Cl.14(6290) |
- |
800 |
|
- |
CL 15(6290) |
- |
2000 |
|
- |
CL 16(6290) |
- |
800 |
|
- |
Cl.17(6290) |
- |
500 |
|
- |
CL 18(6290) |
- |
1000 |
|
- |
CL 19(6290) |
- |
1000 |
|
- |
Cl.20(6290) |
- |
700 |
|
- |
Cl 21(6290) |
- |
1000 |
|
- |
Cl.22, 22.101, 22.102, 22.103, 22.104,22.105, 22.106, 22.107, 22.108,22.109(6290) |
- |
1000 |
|
- |
Cl.23(6290) |
- |
600 |
|
- |
Cl.24,24.101(6290) |
- |
900 |
|
- |
CL 25(6290) |
- |
900 |
|
- |
Cl.26(6290) |
- |
900 |
|
- |
Cl.27(6290) |
- |
800 |
|
- |
Cl.28(6290) |
- |
500 |
|
- |
Cl.29(6290) |
- |
700 |
|
- |
Cl.30(6290) |
- |
1000 |
|
- |
Cl.31(6290) |
- |
800 |
|
- |
Cl.32(6290) |
- |
500 |
|
- |
Cl.33(6290) |
- |
100 |
|
- |
Cl.101,101.1 ,101.2 101.3 ,101.4, 101.5 101.6 ,101.7(6290) |
- |
1700 |
|
- |
CL 102(6290) |
- |
1700 |
|
- |
Cl.103,103.1,103.2, 103.3(6290) |
- |
1800 |
|
- |
Cl.104.1, 104.2(6290) |
- |
1800 |
|
- |
Cl.105,105.1,105.2,105.3,105.4,105.(6290) |
- |
2700 |
|
- |
Cl.106,106.1,106.2(6290) |
- |
2700 |
|
- |
CL 107.1(6290) |
- |
2800 |
|
- |
Cl.107.2,107.3(6290) |
- |
3000 |
|
- |
|
Complete
|
|
23 Jun, 2025 |
- |
6 |
IS 13273 (1991) |
Vitreous enamelled inner tanks for storage water heater - specification |
-
|
27000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
Cl. 5.3.2.1(1238) |
- |
500 |
|
- |
Cl. 5.3.2.1(1238) |
- |
500 |
|
- |
Cl. 5.3.2.3(13273) |
- |
2000 |
|
- |
Cl 5.3.2.2(13273) |
- |
2500 |
|
- |
Cl. 5.3.3(13273) |
- |
1500 |
|
- |
Cl. 5.3.2.2(3972(P-2/Sec-1)) |
- |
500 |
|
- |
Cl. 5.3.2.2(3972(P-2/Sec-1)) |
- |
3000 |
|
- |
Cl. 5.3.2.2(3972(P-2/Sec-1)) |
- |
3000 |
|
- |
Cl. 5.3.2.2(3972(P-2/Sec-1)) |
- |
2500 |
|
- |
Cl. 5.3.2.5(13273) |
- |
3500 |
|
- |
Cl. 5.4(13273) |
- |
2500 |
|
- |
Cl. 5.5(13273) |
- |
5000 |
|
- |
|
Complete
|
|
23 Jun, 2025 |
- |
7 |
IS 12510 (1988) |
Specification for wall clocks (Battery Operated) |
-
|
10000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
Cl. 3, 3.0 to 3.5, 3.5.1 to 3.5.3(12510) |
- |
1500 |
|
- |
Cl. 4, 4.1 to 4.4(12510) |
- |
5000 |
|
- |
Cl. 3, 3.0 to 3.5, 3.5.1 to 3.5.3(12510) |
- |
1500 |
|
- |
Cl. 4, 4.1 to 4.4(12510) |
- |
5000 |
|
- |
Cl. 5, 5.1, 5.2, 5.2.1, 5.2.1.1, 5.2.2(12510) |
- |
1500 |
|
- |
Cl. 7(12510) |
- |
1000 |
|
- |
Cl. 8, 8.1(12510) |
- |
1000 |
|
- |
|
Complete
|
|
23 Jun, 2025 |
- |
8 |
IS/IEC 60695 : Part 11 : Sec 10 (2013) |
Fire hazard testing: Part 11 test flames :: Sec 10 50 w horizontal and vertical flame test methods |
-
|
40000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
Cl. 8(60695-11-10) |
- |
20000 |
|
- |
Cl. 9(60695-11-10) |
- |
20000 |
|
- |
|
Complete
|
|
23 Jun, 2025 |
- |
9 |
IS 7872 (2020) |
Deep Freezers - Specification ( Second Revision ) |
-
|
165000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
5(Refrigeration system) |
- |
5000 |
|
- |
5.4.2(Individual Strength - Pressure Test) |
- |
833 |
|
- |
5.4.3(Individual Strength - Pressure Test) |
- |
833 |
|
- |
5.4.4(Fatigue Test) |
- |
833 |
|
- |
6(Safety Requirements) |
- |
7000 |
|
- |
7(Sound Pressure Level) |
- |
8000 |
|
- |
8(Freezer Storage Capacity) |
- |
15000 |
|
- |
11.1(No load Pull down Test) |
- |
25000 |
|
- |
11.2(Energy Consumption Test) |
- |
35000 |
|
- |
11.3(Temperature Rise Test) |
- |
20000 |
|
- |
11.4(Door Seal Test) |
- |
10000 |
|
- |
11.5(Mechanical Strength of Shelves and Similar Components) |
- |
10000 |
|
- |
11.6(Thermal Insulation Test ( External Condensation)) |
- |
10000 |
|
- |
11.7(Pressure Test) |
- |
10000 |
|
- |
13(Marking and Instruction) |
- |
1500 |
|
- |
4.8(Door and Fittings) |
- |
2500 |
|
- |
5.5(Strength Pressure test for components) |
- |
833 |
|
- |
5.6(External surface condensation test) |
- |
833 |
|
- |
5.1(Sound level) |
- |
833 |
|
- |
6(Measurement of freezer storage
capacity) |
- |
3500 |
|
- |
6.11(Volume measurement Water fill method) |
- |
3500 |
|
- |
9.1(No load test) |
- |
500 |
|
- |
9.2.1(Pull down time) |
- |
500 |
|
- |
9.2.2(Power consumption & percentage running time) |
- |
500 |
|
- |
|
Complete
|
|
23 Jun, 2025 |
- |
10 |
IS/IEC 61730 : PART 1 (2016) |
Photovoltaic (PV) Module Safety Qualification Part 1 Requirements for Construction ( First Revision ) |
-
|
190000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
3.0(Application Classes) |
- |
7500 |
|
- |
4.0(Construction Requirements) |
- |
10000 |
|
- |
5.0(Polymeric Materials) |
- |
10000 |
|
- |
4
IS/IEC 61730-1( Classification, Application and Inteded Use) |
- |
12500 |
|
- |
5, 5.1
IS/IEC 61730-1( Requirements for design and Construction) |
- |
10000 |
|
- |
5.2
IS/IEC 61730-1( Marking and Documentation) |
- |
12500 |
|
- |
5.3, 5.3.1
IS/IEC 61730-1( Electrical Components and Insualtion) |
- |
35000 |
|
- |
5.3.2
IS/IEC 61730-1( Internal Wiring) |
- |
3888 |
|
- |
5.3.3
IS/IEC 61730-1( External Wirings and cables) |
- |
3888 |
|
- |
5.3.4
IS/IEC 61730-1( Connectors) |
- |
3888 |
|
- |
5.3.5
IS/IEC 61730-1( Junction Box for PV modules) |
- |
3888 |
|
- |
5.3.6
IS/IEC 61730-1( Front sheet and back Sheet) |
- |
3888 |
|
- |
5.3.7
IS/IEC 61730-1( Insulation Barrier) |
- |
3888 |
|
- |
5.3.8
IS/IEC 61730-1( Electrical Connections) |
- |
3888 |
|
- |
5.3.9
IS/IEC 61730-1( Encapsulants) |
- |
3888 |
|
- |
5.3.10
IS/IEC 61730-1( Bypass Diodes) |
- |
3888 |
|
- |
5.4, 5.4.1
IS/IEC 61730-1( Mechanical and Electromechanical connections) |
- |
45000 |
|
- |
5.4.2
IS/IEC 61730-1( Screw Connctions) |
- |
7500 |
|
- |
5.4.3
IS/IEC 61730-1( Rivets) |
- |
7500 |
|
- |
5.4.4
IS/IEC 61730-1( Thread Cutting Screws) |
- |
7500 |
|
- |
5.4.5
IS/IEC 61730-1( Form/Press/Tight/Fit) |
- |
7500 |
|
- |
5.4.6
IS/IEC 61730-1( Connections by adhesives) |
- |
7500 |
|
- |
5.4.7
IS/IEC 61730-1( Other Connections) |
- |
7500 |
|
- |
5.5, 5.5.1
IS/IEC 61730-1( Materials) |
- |
22500 |
|
- |
5.5.2
IS/IEC 61730-1( Polymeric Materials) |
- |
2500 |
|
- |
5.5.2.3.2
IS/IEC 61730-1( Endurance to Electrical Stress) |
- |
2500 |
|
- |
5.5.2.3.3
IS/IEC 61730-1( Endurance to thermal stress-RTE (RTI) or TI ) |
- |
2500 |
|
- |
5.5.2.3.4
IS/IEC 61730-1( Polymeric Insulating materials used as external Parts) |
- |
2500 |
|
- |
5.5.2.3.5
IS/IEC 61730-1(Polymeric Insulating Parts supporting live Parts) |
- |
2500 |
|
- |
5.5.2.4
IS/IEC 61730-1(Polymeric Meterial used for Mechanical functions ) |
- |
2500 |
|
- |
5.5.3, 5.5.3.1
IS/IEC 61730-1(Metallic materials) |
- |
2500 |
|
- |
5.5.3.2
IS/IEC 61730-1( Current Carrying Parts) |
- |
2500 |
|
- |
5.5.4
IS/IEC 61730-1(Adhesives) |
- |
2500 |
|
- |
5.6, 5.6.1
IS/IEC 61730-1( Protection Agianst Electric Shock) |
- |
25000 |
|
- |
5.6.2
IS/IEC 61730-1( Protection Agianst accessibility to hazardeous live parts) |
- |
8333 |
|
- |
5.6.3
IS/IEC 61730-1(Insulation Coordination) |
- |
8333 |
|
- |
5.6.4
IS/IEC 61730-1( Distance through Insulation) |
- |
8333 |
|
- |
4
IS/IEC 61730-1( Classification, Application and Inteded Use) |
- |
12500 |
|
- |
5, 5.1
IS/IEC 61730-1( Requirements for design and Construction) |
- |
10000 |
|
- |
5.2
IS/IEC 61730-1( Marking and Documentation) |
- |
12500 |
|
- |
5.3, 5.3.1
IS/IEC 61730-1( Electrical Components and Insualtion) |
- |
35000 |
|
- |
5.3.2
IS/IEC 61730-1( Internal Wiring) |
- |
3888 |
|
- |
5.3.3
IS/IEC 61730-1( External Wirings and cables) |
- |
3888 |
|
- |
5.3.4
IS/IEC 61730-1( Connectors) |
- |
3888 |
|
- |
5.3.5
IS/IEC 61730-1( Junction Box for PV modules) |
- |
3888 |
|
- |
5.3.6
IS/IEC 61730-1( Front sheet and back Sheet) |
- |
3888 |
|
- |
5.3.7
IS/IEC 61730-1( Insulation Barrier) |
- |
3888 |
|
- |
5.3.8
IS/IEC 61730-1( Electrical Connections) |
- |
3888 |
|
- |
5.3.9
IS/IEC 61730-1( Encapsulants) |
- |
3888 |
|
- |
5.3.10
IS/IEC 61730-1( Bypass Diodes) |
- |
3888 |
|
- |
5.4, 5.4.1
IS/IEC 61730-1( Mechanical and Electromechanical connections) |
- |
45000 |
|
- |
5.4.2
IS/IEC 61730-1( Screw Connctions) |
- |
7500 |
|
- |
5.4.3
IS/IEC 61730-1( Rivets) |
- |
7500 |
|
- |
5.4.4
IS/IEC 61730-1( Thread Cutting Screws) |
- |
7500 |
|
- |
5.4.5
IS/IEC 61730-1( Form/Press/Tight/Fit) |
- |
7500 |
|
- |
5.4.6
IS/IEC 61730-1( Connections by adhesives) |
- |
7500 |
|
- |
5.4.7
IS/IEC 61730-1( Other Connections) |
- |
7500 |
|
- |
5.5, 5.5.1
IS/IEC 61730-1( Materials) |
- |
22500 |
|
- |
5.5.2
IS/IEC 61730-1( Polymeric Materials) |
- |
2500 |
|
- |
5.5.2.3.2
IS/IEC 61730-1( Endurance to Electrical Stress) |
- |
2500 |
|
- |
5.5.2.3.3
IS/IEC 61730-1( Endurance to thermal stress-RTE (RTI) or TI ) |
- |
2500 |
|
- |
5.5.2.3.4
IS/IEC 61730-1( Polymeric Insulating materials used as external Parts) |
- |
2500 |
|
- |
5.5.2.3.5
IS/IEC 61730-1(Polymeric Insulating Parts supporting live Parts) |
- |
2500 |
|
- |
5.5.2.4
IS/IEC 61730-1(Polymeric Meterial used for Mechanical functions ) |
- |
2500 |
|
- |
5.5.3, 5.5.3.1
IS/IEC 61730-1(Metallic materials) |
- |
2500 |
|
- |
5.5.3.2
IS/IEC 61730-1( Current Carrying Parts) |
- |
2500 |
|
- |
5.5.4
IS/IEC 61730-1(Adhesives) |
- |
2500 |
|
- |
5.6, 5.6.1
IS/IEC 61730-1( Protection Agianst Electric Shock) |
- |
25000 |
|
- |
5.6.2
IS/IEC 61730-1( Protection Agianst accessibility to hazardeous live parts) |
- |
833 |
|
- |
5.6.3
IS/IEC 61730-1(Insulation Coordination) |
- |
833 |
|
- |
5.6.4
IS/IEC 61730-1( Distance through Insulation) |
- |
833 |
|
- |
|
Complete
|
|
23 Jun, 2025 |
- |
11 |
IS/IEC 60335 : Part 2 : Sec 89 (2010) |
Household and similar electrical appliances - Safety: Part 2 - 89: particular requirements for commercial refrigerating appliances with an incorporated or remote refrigerant unit or compressor |
-
|
115000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
7.1 , 7.12, 7.14,7.15(Marking) |
- |
3400 |
|
- |
8, 8.1(Protection against access to live parts) |
- |
1200 |
|
- |
8.1.1 to 8.1.5(Protection against access to live parts) |
- |
1200 |
|
- |
8.2(Protection against access to live parts) |
- |
1200 |
|
- |
10.1(Power input and current) |
- |
2500 |
|
- |
10.101
(Power input and current) |
- |
2500 |
|
- |
11(TEMPERATURE RISE) |
- |
5000 |
|
- |
11.2(TEMPERATURE RISE) |
- |
555 |
|
- |
11.4(TEMPERATURE RISE) |
- |
555 |
|
- |
11.5(TEMPERATURE RISE) |
- |
555 |
|
- |
11.6(TEMPERATURE RISE) |
- |
555 |
|
- |
11.7(TEMPERATURE RISE) |
- |
555 |
|
- |
11.8(TEMPERATURE RISE) |
- |
555 |
|
- |
11.101(TEMPERATURE RISE) |
- |
555 |
|
- |
11.102(TEMPERATURE RISE) |
- |
555 |
|
- |
11.103(TEMPERATURE RISE) |
- |
555 |
|
- |
13(ELECTRICAL INSULATION AND
LEAKAGE CURRENT AT OPERATING
TEMPERATURE) |
- |
4500 |
|
- |
13.2(ELECTRICAL INSULATION AND
LEAKAGE CURRENT AT OPERATING
TEMPERATURE) |
- |
2250 |
|
- |
13.3 & table 4,5(ELECTRICAL INSULATION AND
LEAKAGE CURRENT AT OPERATING
TEMPERATURE) |
- |
2250 |
|
- |
14(Transient Over Voltage & table 6) |
- |
4000 |
|
- |
15(Moisture resistance) |
- |
12000 |
|
- |
15.1.1(Moisture resistance) |
- |
1714 |
|
- |
15.1.2(Moisture resistance) |
- |
1714 |
|
- |
15.2(Moisture resistance) |
- |
1714 |
|
- |
15.3(Moisture resistance) |
- |
1714 |
|
- |
15.101(Moisture resistance) |
- |
1714 |
|
- |
15.102(Moisture resistance) |
- |
1714 |
|
- |
15.103(Moisture resistance) |
- |
1714 |
|
- |
16 & 16.1(Leakage current and electric strength) |
- |
5500 |
|
- |
16.2(Leakage current and electric strength) |
- |
2750 |
|
- |
16.3 & table 7(Leakage current and electric strength) |
- |
2750 |
|
- |
17(Overload protection of transformers and associated circuits) |
- |
4000 |
|
- |
19(ABNORMAL OPERATION) |
- |
15000 |
|
- |
19.2(ABNORMAL OPERATION) |
- |
790 |
|
- |
19.3(ABNORMAL OPERATION) |
- |
790 |
|
- |
19.4(ABNORMAL OPERATION) |
- |
790 |
|
- |
19.5(ABNORMAL OPERATION) |
- |
790 |
|
- |
19.6(ABNORMAL OPERATION) |
- |
790 |
|
- |
19.7 & table 8(ABNORMAL OPERATION) |
- |
790 |
|
- |
19.8(ABNORMAL OPERATION) |
- |
790 |
|
- |
19.9(ABNORMAL OPERATION) |
- |
790 |
|
- |
19.1(ABNORMAL OPERATION) |
- |
790 |
|
- |
19.11(ABNORMAL OPERATION) |
- |
790 |
|
- |
19.11.1(ABNORMAL OPERATION) |
- |
790 |
|
- |
19.11.2(ABNORMAL OPERATION) |
- |
790 |
|
- |
19.11.3(ABNORMAL OPERATION) |
- |
790 |
|
- |
19.11.4(ABNORMAL OPERATION) |
- |
790 |
|
- |
19.11.4.1(ABNORMAL OPERATION) |
- |
790 |
|
- |
19.12(ABNORMAL OPERATION) |
- |
790 |
|
- |
19.13(ABNORMAL OPERATION) |
- |
790 |
|
- |
19.14(ABNORMAL OPERATION) |
- |
790 |
|
- |
19.15(ABNORMAL OPERATION) |
- |
790 |
|
- |
20.1(Stability and mechanical hazards) |
- |
2500 |
|
- |
20.2(Stability and mechanical hazards) |
- |
2500 |
|
- |
21.1(MECHANICAL STRENGTH) |
- |
1000 |
|
- |
21.2(MECHANICAL STRENGTH) |
- |
1000 |
|
- |
22.101(MECHANICAL STRENGTH) |
- |
1000 |
|
- |
22.102(MECHANICAL STRENGTH) |
- |
1000 |
|
- |
22.1(Constructions) |
- |
3000 |
|
- |
22.2(Constructions) |
- |
230 |
|
- |
22.3(Constructions) |
- |
230 |
|
- |
22.4(Constructions) |
- |
230 |
|
- |
22.5(Constructions) |
- |
230 |
|
- |
22.6(Constructions) |
- |
230 |
|
- |
22.7 to 22.10(Constructions) |
- |
230 |
|
- |
22.11(Constructions) |
- |
230 |
|
- |
22.12(Constructions) |
- |
230 |
|
- |
22.13 to 22.52(Constructions) |
- |
230 |
|
- |
22.101 to 22.102(Constructions) |
- |
230 |
|
- |
22.103(Constructions) |
- |
230 |
|
- |
22.104(Constructions) |
- |
230 |
|
- |
22.105 to 22.114(Constructions) |
- |
230 |
|
- |
22.104(Constructions) |
- |
230 |
|
- |
23.1 & 23.2(Internal wiring) |
- |
1000 |
|
- |
23.3(Internal wiring) |
- |
1000 |
|
- |
23.4(Internal wiring) |
- |
1000 |
|
- |
23.5 to 23.8(Internal wiring) |
- |
1000 |
|
- |
23.9 ,23.10(Internal wiring) |
- |
1000 |
|
- |
24(Components) |
- |
8000 |
|
- |
24.2 to 24.5 (Components) |
- |
4000 |
|
- |
25.1(Supply connection and external flexible cords) |
- |
2500 |
|
- |
25.2 to 25.25(Supply connection and external flexible cords) |
- |
2500 |
|
- |
26, 26.1 to 26.11(Terminals for external conductors) |
- |
2000 |
|
- |
27, 27.1 to 27.6(Provision for earthing) |
- |
3000 |
|
- |
28.1, Table No.-14(Screws and connections) |
- |
2000 |
|
- |
28.2 to 28.4(Screws and connections) |
- |
2000 |
|
- |
29 and table (creepage and Clearances distances ) |
- |
1500 |
|
- |
29.1 & 29.3(creepage and Clearances distances ) |
- |
1500 |
|
- |
30.1(Resistance to heat and fire) |
- |
1800 |
|
- |
30.2(Resistance to heat and fire) |
- |
1800 |
|
- |
30.2.1(Resistance to heat and fire) |
- |
1800 |
|
- |
30.2.2(Resistance to heat and fire) |
- |
1800 |
|
- |
30.2.3(Resistance to heat and fire) |
- |
1800 |
|
- |
31(Resistance to rusting) |
- |
3000 |
|
- |
7.1 , 7.12, 7.14,7.15(Marking) |
- |
3400 |
|
- |
8, 8.1(Protection against access to live parts) |
- |
1200 |
|
- |
8.1.1 to 8.1.5(Protection against access to live parts) |
- |
1200 |
|
- |
8.2(Protection against access to live parts) |
- |
1200 |
|
- |
10.1(Power input and current) |
- |
2500 |
|
- |
10.101
(Power input and current) |
- |
2500 |
|
- |
11(TEMPERATURE RISE) |
- |
5000 |
|
- |
11.2(TEMPERATURE RISE) |
- |
555 |
|
- |
11.4(TEMPERATURE RISE) |
- |
555 |
|
- |
11.5(TEMPERATURE RISE) |
- |
555 |
|
- |
11.6(TEMPERATURE RISE) |
- |
555 |
|
- |
11.7(TEMPERATURE RISE) |
- |
555 |
|
- |
11.8(TEMPERATURE RISE) |
- |
555 |
|
- |
11.101(TEMPERATURE RISE) |
- |
555 |
|
- |
11.102(TEMPERATURE RISE) |
- |
555 |
|
- |
11.103(TEMPERATURE RISE) |
- |
555 |
|
- |
13(ELECTRICAL INSULATION AND
LEAKAGE CURRENT AT OPERATING
TEMPERATURE) |
- |
4500 |
|
- |
13.2(ELECTRICAL INSULATION AND
LEAKAGE CURRENT AT OPERATING
TEMPERATURE) |
- |
2250 |
|
- |
13.3 & table 4,5(ELECTRICAL INSULATION AND
LEAKAGE CURRENT AT OPERATING
TEMPERATURE) |
- |
2250 |
|
- |
14(Transient Over Voltage & table 6) |
- |
4000 |
|
- |
15(Moisture resistance) |
- |
12000 |
|
- |
15.1.1(Moisture resistance) |
- |
1714 |
|
- |
15.1.2(Moisture resistance) |
- |
1714 |
|
- |
15.2(Moisture resistance) |
- |
1714 |
|
- |
15.3(Moisture resistance) |
- |
1714 |
|
- |
15.101(Moisture resistance) |
- |
1714 |
|
- |
15.102(Moisture resistance) |
- |
1714 |
|
- |
15.103(Moisture resistance) |
- |
1714 |
|
- |
16 & 16.1(Leakage current and electric strength) |
- |
5500 |
|
- |
16.2(Leakage current and electric strength) |
- |
2750 |
|
- |
16.3 & table 7(Leakage current and electric strength) |
- |
2750 |
|
- |
17(Overload protection of transformers and associated circuits) |
- |
4000 |
|
- |
19(ABNORMAL OPERATION) |
- |
15000 |
|
- |
19.2(ABNORMAL OPERATION) |
- |
790 |
|
- |
19.3(ABNORMAL OPERATION) |
- |
790 |
|
- |
19.4(ABNORMAL OPERATION) |
- |
790 |
|
- |
19.5(ABNORMAL OPERATION) |
- |
790 |
|
- |
19.7 & table 8(ABNORMAL OPERATION) |
- |
790 |
|
- |
19.8(ABNORMAL OPERATION) |
- |
790 |
|
- |
19.9(ABNORMAL OPERATION) |
- |
790 |
|
- |
19.11(ABNORMAL OPERATION) |
- |
790 |
|
- |
19.11.1(ABNORMAL OPERATION) |
- |
790 |
|
- |
19.11.2(ABNORMAL OPERATION) |
- |
790 |
|
- |
19.11.3(ABNORMAL OPERATION) |
- |
790 |
|
- |
19.11.4(ABNORMAL OPERATION) |
- |
790 |
|
- |
19.11.4.1(ABNORMAL OPERATION) |
- |
790 |
|
- |
19.12(ABNORMAL OPERATION) |
- |
790 |
|
- |
19.13(ABNORMAL OPERATION) |
- |
790 |
|
- |
19.14(ABNORMAL OPERATION) |
- |
790 |
|
- |
19.15(ABNORMAL OPERATION) |
- |
790 |
|
- |
20.1(Stability and mechanical hazards) |
- |
2500 |
|
- |
20.2(Stability and mechanical hazards) |
- |
2500 |
|
- |
21.1(MECHANICAL STRENGTH) |
- |
1000 |
|
- |
21.2(MECHANICAL STRENGTH) |
- |
1000 |
|
- |
22.101(MECHANICAL STRENGTH) |
- |
1000 |
|
- |
22.102(MECHANICAL STRENGTH) |
- |
1000 |
|
- |
22.1(Constructions) |
- |
3000 |
|
- |
22.2(Constructions) |
- |
230 |
|
- |
22.3(Constructions) |
- |
230 |
|
- |
22.4(Constructions) |
- |
230 |
|
- |
22.5(Constructions) |
- |
230 |
|
- |
22.6(Constructions) |
- |
230 |
|
- |
22.7 to 22.10(Constructions) |
- |
230 |
|
- |
22.11(Constructions) |
- |
230 |
|
- |
22.12(Constructions) |
- |
230 |
|
- |
22.13 to 22.52(Constructions) |
- |
230 |
|
- |
22.101 to 22.102(Constructions) |
- |
230 |
|
- |
22.103(Constructions) |
- |
230 |
|
- |
22.104(Constructions) |
- |
230 |
|
- |
22.104(Constructions) |
- |
230 |
|
- |
22.105 to 22.114(Constructions) |
- |
230 |
|
- |
22.104(Constructions) |
- |
230 |
|
- |
23.1 & 23.2(Internal wiring) |
- |
1000 |
|
- |
23.3(Internal wiring) |
- |
1000 |
|
- |
23.4(Internal wiring) |
- |
1000 |
|
- |
23.5 to 23.8(Internal wiring) |
- |
1000 |
|
- |
23.9 ,23.10(Internal wiring) |
- |
1000 |
|
- |
24(Components) |
- |
8000 |
|
- |
24.2 to 24.5 (Components) |
- |
4000 |
|
- |
25.1(Supply connection and external flexible cords) |
- |
2500 |
|
- |
25.2 to 25.25(Supply connection and external flexible cords) |
- |
2500 |
|
- |
26, 26.1 to 26.11(Terminals for external conductors) |
- |
2000 |
|
- |
27, 27.1 to 27.6(Provision for earthing) |
- |
3000 |
|
- |
28.1, Table No.-14(Screws and connections) |
- |
2000 |
|
- |
28.2 to 28.4(Screws and connections) |
- |
2000 |
|
- |
29 and table (creepage and Clearances distances ) |
- |
1500 |
|
- |
29.1 & 29.3(creepage and Clearances distances ) |
- |
1500 |
|
- |
30.1(Resistance to heat and fire) |
- |
9000 |
|
- |
30.2(Resistance to heat and fire) |
- |
1800 |
|
- |
30.2.1(Resistance to heat and fire) |
- |
1800 |
|
- |
30.2.2(Resistance to heat and fire) |
- |
1800 |
|
- |
30.2.3(Resistance to heat and fire) |
- |
1800 |
|
- |
31(Resistance to rusting) |
- |
3000 |
|
- |
|
Complete
|
|
23 Jun, 2025 |
- |
12 |
IS 16221 : Part 2 (2015) |
Safety of power converters for use in photovoltaic power systems: Part 2 particular requirements for inverters |
-
|
400000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
4(General Test Requireements) |
- |
50000 |
|
- |
5(Marking and documentation) |
- |
20000 |
|
- |
6(Environmental requirements and conditions) |
- |
50000 |
|
- |
7(Protection against electric shock and energy hazards) |
- |
50000 |
|
- |
8(Protection against Mechanical Hazards) |
- |
50000 |
|
- |
9(Protection against Fire Hazards) |
- |
50000 |
|
- |
10(Protection against Sonic Pressure Hazards) |
- |
25000 |
|
- |
11(Protection against Liquid Hazards) |
- |
25000 |
|
- |
12(Protection against Chemical Hazards) |
- |
20000 |
|
- |
13(Physical Requirements) |
- |
30000 |
|
- |
14(Components) |
- |
30000 |
|
- |
14(Components) |
- |
30000 |
|
- |
4(General Test Requirements) |
- |
50000 |
|
- |
5(Marking and documentation) |
- |
20000 |
|
- |
6(Environmental requirements and conditions) |
- |
50000 |
|
- |
7(Protection against electric shock and energy hazards) |
- |
50000 |
|
- |
8(Protection against Mechanical Hazards) |
- |
50000 |
|
- |
9(Protection against Fire Hazards) |
- |
50000 |
|
- |
10(Protection against Sonic Pressure Hazards) |
- |
25000 |
|
- |
11(Protection against Liquid Hazards) |
- |
25000 |
|
- |
12(Protection against Chemical Hazards) |
- |
20000 |
|
- |
13(Physical Requirements) |
- |
30000 |
|
- |
14(Components) |
- |
30000 |
|
- |
|
Complete
|
|
23 Jun, 2025 |
- |
13 |
IS 16103 : Part 1 (2012) |
Led modules for general lighting: Part 1 safety requirements |
-
|
37500 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
7(Marking) |
- |
4000 |
|
1000 |
21(Heat management) |
- |
4000 |
|
- |
8(Terminals) |
- |
1500 |
|
- |
9(PROVISION FOR EARTHING) |
- |
2000 |
|
- |
10(Protection against accidental contact with live parts) |
- |
2000 |
|
- |
11(Mositure Resistance and Insulation) |
- |
8000 |
|
- |
12(Electric Strength) |
- |
5000 |
|
- |
13(Fault conditions) |
- |
3000 |
|
- |
15(Construction) |
- |
1000 |
|
- |
16(Creepage distance and clearances) |
- |
1000 |
|
- |
17(Screws, current carrying parts and connections) |
- |
2000 |
|
- |
18(Resistance to heat, fire and tracking) |
- |
6000 |
|
- |
19(Resistance to corrosion) |
- |
1000 |
|
- |
|
Complete
|
|
23 Jun, 2025 |
- |
14 |
IS 14286 : Part 1 : Sec 1 (2019) |
Terrestrial photovoltaic (PV) modules - Design qualification and type approval: Part 1 test requirements: Sec 1 special requirements for testing of crystalline silicon photovoltaic (Pv) modules (Second Revision) |
-
|
700000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
11.1(Visual inspection (MQT 01)) |
- |
20000 |
|
- |
11.2(Maximum power determination (MQT 02)) |
- |
20000 |
|
- |
11.3(Insulation test (MQT 03)) |
- |
10000 |
|
- |
11.4(Measurement of temperature coefficients (MQT 04)) |
- |
30000 |
|
- |
11.5(Measurement of nominal module operating temperature (NMOT)
(MQT 05)) |
- |
30000 |
|
- |
11.6(Performance at STC and NMOT
(MQT 06)) |
- |
30000 |
|
- |
11.7(Performance at low irradiance
(MQT 07)) |
- |
30000 |
|
- |
11.8(Outdoor exposure test (MQT 08)) |
- |
30000 |
|
- |
11.9(Hot-spot endurance test (MQT 09)) |
- |
45000 |
|
- |
11.1(UV preconditioning test
(MQT 10)) |
- |
30000 |
|
- |
11.11(Thermal cycling test (MQT 11)) |
- |
70000 |
|
- |
11.12(Humidity-freeze test (MQT 12)) |
- |
85000 |
|
- |
11.13(Damp heat test (MQT 13)) |
- |
100000 |
|
- |
11.14(Robustness of terminations
(MQT 14)) |
- |
20000 |
|
- |
11.15(Wet leakage current test (MQT 15)) |
- |
20000 |
|
- |
11.16(Static mechanical load test
(MQT 16)) |
- |
30000 |
|
- |
11.17(Hail test (MQT 17)) |
- |
30000 |
|
- |
11.18(Bypass diode thermal test (MQT 18)) |
- |
40000 |
|
- |
11.19(Stabilization (MQT 19)) |
- |
30000 |
|
- |
|
Complete
|
|
23 Jun, 2025 |
- |
15 |
IS 14286 : Part 1 (2019) |
Terrestrial photovoltaic (PV) modules - Design qualification and type approval: Part 1 test requirements (Second Revision) |
-
|
1100000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
11(Test flow and procedures) |
- |
100000 |
|
- |
5(Marking and documentation) |
- |
100000 |
|
- |
7(Pass criteria) |
- |
300000 |
|
- |
6(Testing) |
- |
100000 |
|
- |
8(Major visual defects) |
- |
200000 |
|
- |
8(Major visual defects) |
- |
200000 |
|
- |
9(Report) |
- |
150000 |
|
- |
10(Modifications) |
- |
150000 |
|
- |
|
Complete
|
|
23 Jun, 2025 |
- |
16 |
IS 302 : Part 2 : Sec 8 (1994) |
Safety of household and similar electrical appliances : part 2 particular requirements, section 8 electrical shavers hair, clippers and similar appliances |
-
|
24000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
5(Rating) |
- |
500 |
|
- |
6(Classification) |
- |
500 |
|
- |
7(Marking/ Marking & Instructions) |
- |
500 |
|
- |
8(Protection against Electric Shock/ Protection against Access to Live Parts) |
- |
750 |
|
- |
9(Starting Of Motor Operated Appliances) |
- |
500 |
|
- |
10(Power Input
& Current) |
- |
1000 |
|
- |
11(Temperature Rise/Heating) |
- |
1500 |
|
- |
13(Leakage Current and Electric Strength at Operating Temperature) |
- |
750 |
|
- |
14(Radio and Television Interference Suppression/ Transient Over Voltage) |
- |
750 |
|
- |
15(Moisture Resistance) |
- |
2000 |
|
- |
16(Leakage Current and Electric Strength) |
- |
750 |
|
- |
17(Overload Protection/ Overload Protection of Transformers & Associated Circuits) |
- |
250 |
|
- |
18(Endurance) |
- |
1500 |
|
- |
19(Abnormal Operation) |
- |
2000 |
|
- |
20(Stability & Mechanical Hazards) |
- |
500 |
|
- |
21(Mechanical strength) |
- |
750 |
|
- |
22(Construction) |
- |
1000 |
|
- |
23(Internal wiring) |
- |
750 |
|
- |
24(Component) |
- |
1000 |
|
- |
25(Supply Connection & External Flexible Cables and Cords) |
- |
1500 |
|
- |
26(Terminals For External Conductors) |
- |
750 |
|
- |
27(Provision For Earthing) |
- |
1000 |
|
- |
28(Screws & Connection) |
- |
750 |
|
- |
29(Clearances, Creepage Distances & Solid Insulation) |
- |
1000 |
|
- |
30(Resistance to Heat & Fire) |
- |
750 |
|
- |
31(Resistance to Rusting) |
- |
750 |
|
- |
32(Radiation ,Toxicity and similar hazards) |
- |
250 |
|
- |
|
Complete
|
|
23 Jun, 2025 |
- |
17 |
IS 302 : Part 2 : Sec 6 (2009) |
Safety of household and similar electrical appliances: Part 2 particular requirements: Sec 6 cooking ranges, hobs, ovens and similar appliances (First Revision) |
-
|
19000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
6.0(Classification) |
- |
250 |
|
- |
7.0(Marking and instructions) |
- |
250 |
|
- |
8.0(Protection against access to live part test) |
- |
250 |
|
- |
9.0(Starting of motor-operated appliances test) |
- |
250 |
|
- |
10.0(Power Input and current test) |
- |
800 |
|
- |
11.0(Heating test) |
- |
1000 |
|
- |
13.0(Leakage current and electric strength test) |
- |
500 |
|
- |
14.0(Transient voltages) |
- |
1200 |
|
- |
15.0(Moisture Resistance) |
- |
1500 |
|
- |
16.0(Leakage current and electric strength test) |
- |
500 |
|
- |
17.0(Overload protection of transformers test) |
- |
250 |
|
- |
18.0(Endurance test) |
- |
250 |
|
- |
19.0(Abnormal Operations) |
- |
1000 |
|
- |
20.0(Stability and Mechanical Hazards) |
- |
700 |
|
- |
21.0(Mechanical Strength) |
- |
700 |
|
- |
22.0(Construction verification related tests) |
- |
1000 |
|
- |
23.0(Internal wiring) |
- |
950 |
|
- |
24.0(Components) |
- |
1000 |
|
- |
25.0(Supply connections and External Flexible Cords) |
- |
1500 |
|
- |
26.0(Terminal for External Conductors) |
- |
500 |
|
- |
27.0(Provision for Earthing) |
- |
950 |
|
- |
28.0(Screws and connections) |
- |
500 |
|
- |
29.0(Clearances and Creepage distances and solid insulation) |
- |
1500 |
|
- |
30.0(Resistance to heat and fire) |
- |
950 |
|
- |
31.0(Resistance to rusting) |
- |
500 |
|
- |
32.0(Radiation, Toxicity and Similar hazards) |
- |
250 |
|
- |
|
Complete
|
|
23 Jun, 2025 |
- |
18 |
IS 302 : Part 2 : Sec 3 (2007) |
Safety of household and similar electrical appliances: Part 2 particular requirements: Sec 3 electric iron (First Revision) |
-
|
10000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
6(Classification- IS 302-1 ) |
- |
200 |
|
- |
6(Classification- IS 302-1) |
- |
200 |
|
- |
7.1(Marking- IS 302-1) |
- |
500 |
|
- |
7.1(Marking- IS 302-1) |
- |
50 |
|
- |
7.1(Marking- IS 302-1) |
- |
50 |
|
- |
7.1(Marking- IS 302-1) |
- |
50 |
|
- |
7.1(Marking- IS 302-1) |
- |
50 |
|
- |
7.1(Marking- IS 302-1) |
- |
50 |
|
- |
7.1(Marking- IS 302-1) |
- |
50 |
|
- |
7.1(Marking- IS 302-1) |
- |
50 |
|
- |
7.1(Marking- IS 302-1) |
- |
50 |
|
- |
7.3(Marking- IS 302-1) |
- |
50 |
|
- |
7.4(Marking- IS 302-1) |
- |
50 |
|
- |
7.6(Marking- IS 302-1) |
- |
50 |
|
- |
7.7(Marking- IS 302-1) |
- |
50 |
|
- |
7.8(Marking- IS 302-1) |
- |
50 |
|
- |
7.11(Marking- IS 302-1) |
- |
50 |
|
- |
7.12(Marking- IS 302-1) |
- |
50 |
|
- |
7.13(Marking- IS 302-1) |
- |
50 |
|
- |
7.14(Marking- IS 302-1) |
- |
50 |
|
- |
7.15(Marking- IS 302-1) |
- |
50 |
|
- |
7.101(Marking) |
- |
50 |
|
- |
8( Protection Against Electric Shock, IS 302-1) |
- |
250 |
|
- |
10(Power Input and Current, IS 302-1) |
- |
600 |
|
- |
11(Heating, IS 302-1) |
- |
500 |
|
- |
11(Heating, IS 302-1) |
- |
500 |
|
500 |
11(Heating, IS 302-1) |
- |
500 |
|
- |
11(Heating, IS 302-1) |
- |
500 |
|
- |
11(Heating, IS 302-1) |
- |
500 |
|
- |
11(Heating, IS 302-1) |
- |
500 |
|
- |
11(Heating, IS 302-1) |
- |
500 |
|
- |
11(Heating, IS 302-1) |
- |
500 |
|
- |
13(Electrical Insulation and Leakage Current at Operating Temperature: Leakage current, IS 302-1) |
- |
300 |
|
- |
13(Electrical Insulation and Leakage Current at Operating Temperature: High Voltage, IS 302-1) |
- |
300 |
|
- |
14(Transient Over Voltages, IS 302-1) |
- |
500 |
|
- |
15.1(Moisture Resistance, IS 302-1) |
- |
300 |
|
- |
15.2(Moisture Resistance, IS 302-1) |
- |
300 |
|
- |
15.3(Moisture Resistance, IS 302-1) |
- |
300 |
|
- |
16(Electrical Insulation and Leakage Current at Operating Temperature: Leakage current, IS 302-1) |
- |
450 |
|
- |
16(Electrical Insulation and Leakage Current at Operating Temperature: High Voltage, IS 302-1) |
- |
450 |
|
- |
19.4(Abnormal Operation, IS 302-1) |
- |
100 |
|
- |
19.4(Abnormal Operation, IS 302-1) |
- |
100 |
|
- |
19.5(Abnormal Operation, IS 302-1) |
- |
100 |
|
- |
19.5(Abnormal Operation, IS 302-1) |
- |
100 |
|
- |
19.7(Abnormal Operation) |
- |
100 |
|
- |
19.9(Abnormal Operation) |
- |
100 |
|
- |
19.1(Abnormal Operation) |
- |
100 |
|
- |
19.101(Abnormal Operation) |
- |
100 |
|
- |
20.1(Stability & Mechanical Hazards, IS 302-1) |
- |
150 |
|
- |
20.2(Stability & Mechanical Hazards, IS 302-1) |
- |
150 |
|
- |
21.1(Mechanical Strength, IS 302-1) |
- |
200 |
|
- |
21.2(Mechanical Strength, IS 302-1) |
- |
200 |
|
- |
22(Construction, IS 302-1) |
- |
400 |
|
- |
23.1(Internal Wiring, IS 302-1) |
- |
200 |
|
- |
23.2(Internal Wiring, IS 302-1) |
- |
200 |
|
- |
23.3(Internal Wiring, IS 302-1) |
- |
200 |
|
- |
23.4(Internal Wiring, IS 302-1) |
- |
200 |
|
- |
23.5(Internal Wiring, IS 302-1) |
- |
200 |
|
- |
23.6(Internal Wiring, IS 302-1) |
- |
200 |
|
- |
23.7(Internal Wiring, IS 302-1) |
- |
200 |
|
- |
23.8(Internal Wiring, IS 302-1) |
- |
200 |
|
- |
23.9(Internal Wiring, IS 302-1) |
- |
200 |
|
- |
23.10(Internal Wiring, IS 302-1) |
- |
200 |
|
- |
24.1(Components, IS 302-1) |
- |
100 |
|
- |
24.2(Components, IS 302-1) |
- |
100 |
|
- |
24.5(Components, IS 302-1) |
- |
100 |
|
- |
24.6(Components, IS 302-1) |
- |
100 |
|
- |
25.1(Supply Connection and External Flexible Cords, IS 302-1) |
- |
200 |
|
- |
25.5(Supply Connection and External Flexible Cords, IS 302-1) |
- |
200 |
|
- |
25.6(Supply Connection and External Flexible Cords, IS 302-1) |
- |
200 |
|
- |
25.7(Supply Connection and External Flexible Cords, IS 302-1) |
- |
200 |
|
- |
25.8(Supply Connection and External Flexible Cords, IS 302-1) |
- |
200 |
|
- |
26.9(Supply Connection and External Flexible Cords, IS 302-1) |
- |
200 |
|
- |
25.1(Supply Connection and External Flexible Cords, IS 302-1) |
- |
200 |
|
- |
25.11(Supply Connection and External Flexible Cords, IS 302-1) |
- |
200 |
|
- |
25.12(Supply Connection and External Flexible Cords, IS 302-1) |
- |
200 |
|
- |
25.13(Supply Connection and External Flexible Cords, IS 302-1) |
- |
200 |
|
- |
25.14(Supply Connection and External Flexible Cords, IS 302-1) |
- |
200 |
|
- |
25.14(Supply Connection and External Flexible Cords, IS 302-1) |
- |
200 |
|
- |
25.15(Supply Connection and External Flexible Cords, IS 302-1) |
- |
200 |
|
- |
25.16(Supply Connection and External Flexible Cords, IS 302-1) |
- |
200 |
|
- |
25.17(Supply Connection and External Flexible Cords, IS 302-1) |
- |
200 |
|
- |
25.18(Supply Connection and External Flexible Cords, IS 302-1) |
- |
200 |
|
- |
25.19(Supply Connection and External Flexible Cords, IS 302-1) |
- |
200 |
|
- |
25.2(Supply Connection and External Flexible Cords, IS 302-1) |
- |
200 |
|
- |
25.21(Supply Connection and External Flexible Cords, IS 302-1) |
- |
200 |
|
- |
25.22(Supply Connection and External Flexible Cords, IS 302-1) |
- |
200 |
|
- |
26(Terminals for External Conductors, IS 302-1) |
- |
200 |
|
- |
27.1(Provision for Earthing, IS 302-1) |
- |
60 |
|
- |
27.2(Provision for Earthing, IS 302-1) |
- |
60 |
|
- |
27.3(Provision for Earthing, IS 302-1) |
- |
60 |
|
- |
27.4(Provision for Earthing, IS 302-1) |
- |
60 |
|
- |
27.5(Provision for Earthing, IS 302-1) |
- |
60 |
|
- |
28(Screws & Connections, IS 302-1) |
- |
250 |
|
- |
29.1(Clearances, Creepage distances and Solid Insulation, IS 302-1) |
- |
125 |
|
- |
29.2(Clearances, Creepage distances and Solid Insulation, IS 302-1) |
- |
125 |
|
- |
30.1(Resistance to Heat, Fire & Tracking, IS 302-1) |
- |
250 |
|
- |
30.2(Resistance to Heat, Fire & Tracking, IS 302-1) |
- |
250 |
|
- |
31(Resistance of Rusting, IS 302-1) |
- |
200 |
|
- |
32(Radiation, Toxicity and similar Hazard IS 302-1) |
- |
250 |
|
- |
17(Overload protection of transformers and associated circuits) |
- |
250 |
|
- |
17(Overload protection of transformers and associated circuits) |
- |
250 |
|
- |
17(Overload protection of transformers and associated circuits) |
- |
250 |
|
- |
18(Endurance) |
- |
250 |
|
- |
21.101(Mechanical Strength, IS 302-2-3) |
- |
400 |
|
- |
22.101(Construction) |
- |
400 |
|
- |
22.102(Construction) |
- |
400 |
|
- |
22.103(Construction) |
- |
400 |
|
- |
22.104(Construction) |
- |
400 |
|
- |
22.105(Construction) |
- |
400 |
|
- |
22.106(Construction) |
- |
400 |
|
- |
22.107(Construction) |
- |
400 |
|
- |
24.4(Components, IS 302-1) |
- |
100 |
|
- |
4(General requirement) |
- |
200 |
|
- |
16(Leakage current and electric strength) |
- |
450 |
|
- |
|
Complete
|
|
23 Jun, 2025 |
- |
19 |
IS 5790 (1985) |
Specification for domestic electric cooking ovens (First Revision) |
-
|
80000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
5(Rating) |
- |
1000 |
|
- |
6(Classification) |
- |
500 |
|
- |
7(Marking) |
- |
750 |
|
- |
8(Protection against Access to Live Parts) |
- |
1000 |
|
- |
9(Starting Of Motor Operated Appliances) |
- |
2000 |
|
- |
10(Power Input & Current) |
- |
4000 |
|
- |
11(Temperature Rise/ Heating) |
- |
6500 |
|
- |
12(Operation under overload condition of appliances with heating element) |
- |
5000 |
|
- |
13(Electrical Insulation and Leakage Current at Operating Temperature) |
- |
6500 |
|
- |
14(Radio and Television Interference Suppressions/ Transient Over Voltage) |
- |
4000 |
|
- |
15(Moisture Resistance) |
- |
4500 |
|
- |
16(Insulation Resistance and Electric Strength (After Humidity Treatment)/ Leakage Current and Electric Strength) |
- |
3750 |
|
- |
17(Overload Protection/ Overload Protection of Transformers & Associated Circuits) |
- |
1000 |
|
- |
18(Endurance) |
- |
5000 |
|
- |
19(Abnormal Operation) |
- |
3000 |
|
- |
20(Stability & Mechanical Hazards) |
- |
1000 |
|
- |
21(Mechanical strength) |
- |
1000 |
|
- |
22(Construction) |
- |
2000 |
|
- |
23(Internal wiring) |
- |
2000 |
|
- |
24(Components) |
- |
1000 |
|
- |
25(Supply Connection & External Flexible Cords) |
- |
1000 |
|
- |
26(Terminals For External Conductors) |
- |
1000 |
|
- |
27(Provision For Earthing) |
- |
2000 |
|
- |
28(Screws & Connections) |
- |
2000 |
|
- |
29(Clearances, Creepage Distances & Solid Insulation) |
- |
1500 |
|
- |
30(Resistance to Heat & Fire) |
- |
5000 |
|
- |
31(Resistance to Rusting) |
- |
2500 |
|
- |
32(Radiation ,Toxicity and similar hazards) |
- |
1500 |
|
- |
33(Finish) |
- |
1000 |
|
- |
101(Heating Up Time) |
- |
1500 |
|
- |
102(Heat Losses) |
- |
1500 |
|
- |
103(Uniformity of Temperature) |
- |
1000 |
|
- |
104(Thermostat setting and differential (For automatic ovens only)) |
- |
3000 |
|
- |
|
Complete
|
|
23 Jun, 2025 |
- |
20 |
IS 10322 : Part 5 : Sec 9 (2017) |
Luminaires: Part 5 particular requirements: Sec 9 rope lights |
-
|
40000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
21.4(General Test Requireements) |
- |
2000 |
|
- |
21.5(Classification of Luminaires') |
- |
1000 |
|
- |
21.6(Marking) |
- |
1000 |
|
- |
21.7(Construction) |
- |
3000 |
|
- |
21.8(Creepage Distance and Clearances) |
- |
1000 |
|
- |
21.10(Terminals) |
- |
1000 |
|
- |
21.11(External & Internal Wiring) |
- |
1000 |
|
- |
21.12(Protection against electric shock) |
- |
2000 |
|
- |
21.13(Endurance Tests and Thermal Tests) |
- |
10000 |
|
- |
21.14(Resistance to Dust & Moisture) |
- |
10000 |
|
- |
21.15(Insulation Resistance and Electric Strength) |
- |
3000 |
|
- |
21.16(Resistance to Heat , fire and tracking) |
- |
5000 |
|
- |
|
Complete
|
|
23 Jun, 2025 |
- |
21 |
IS 10617 (2018) |
Hermetic compressors - Specification (Second Revision) |
-
|
1400000 View breakup
For all type of compressor cooling capacity Upto 0.75 kW- Rs. 7,00,000/-
For all type of compressor cooling capacity from 0.75 kW to 2.5 kW - Rs. 9,50,000/-
For all type of compressor cooling capacity from 2.5 kW to 5 kW - Rs. 12,50,000/-
For all type of compressor cooling capacity from 5 kW to 17.5 kW - Rs. 14,00,000/-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
6.1.1 & 5.1 -Table 2, 3, 4,5(Compressor Performance Test & Compressor Capacity Rating Test) |
- |
468000 |
|
- |
Cl. 4 of IS:10617:2018(10617) |
- |
2000 |
|
- |
Cl. 5,5.1 of IS:10617:2018(10617) |
- |
3000 |
|
- |
Cl.6.1.1 of IS:10617:2018(10617) |
- |
468000 |
|
- |
Cl. 6.1.2, 6.1.2.1 of IS:10617:2018(10617) |
- |
5000 |
|
- |
Cl. 6.1.2.2 of IS:10617:2018(10617) |
- |
25000 |
|
- |
Cl. 6.1.2.3 of IS:10617:2018(10617) |
- |
25000 |
|
- |
Cl. 6.1.2.4 of IS:10617:2018(10617) |
- |
25000 |
|
- |
Cl. 6.1.3 of IS:10617(10617) |
- |
20000 |
|
- |
Cl. 6.1.4 of IS:10617:2018(10617) |
- |
5000 |
|
- |
Cl. 6.1.5 of IS:10617:2018(10617) |
- |
5000 |
|
- |
Cl. 6.1.6 of IS:10617:2018(10617) |
- |
20000 |
|
- |
Cl. 6.1.7 of IS:10617:2018(10617) |
- |
25000 |
|
- |
Cl. 6.2 of IS:10617:2018(10617) |
- |
30000 |
|
- |
Cl. 7, 7.1 of IS:10617:2018(10617) |
- |
30000 |
|
- |
Cl. 8, 8.1, 8.2, 8.3, 8.4, 8.5 of IS:10617:2018(10617) |
- |
200000 |
|
- |
Cl. 9 of IS:10617-2018(10617) |
- |
5000 |
|
- |
Cl. 10 of IS:10617-2018(10617) |
- |
2000 |
|
- |
Cl. 11, 11.1, 11.2, 11.2.1 of IS:10617-2018(10617) |
- |
5000 |
|
- |
|
Complete
|
|
23 Jun, 2025 |
Single phase- LBP/MBP/HBP -Cooling capacity upto 17.5 kW
Three phase- LBP/MBP/HBP- Cooling capacity upto 17.5 kW
DC- LBP/MBP/HBP- Cooling capacity upto 17.5 kW |
22 |
IS 1258 (2005) |
Bayonet lamp holders (Fourth Revision) |
-
|
14000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
6(Rating ) |
- |
400 |
|
- |
6(Rating ) |
- |
400 |
|
- |
7(Classification) |
- |
500 |
|
- |
7.2(Classification) |
- |
100 |
|
- |
7.3(Classification) |
- |
100 |
|
- |
7.4(Classification) |
- |
100 |
|
- |
7.5(Classification) |
- |
100 |
|
- |
7.6(Classification) |
- |
100 |
|
- |
9.1(Dimensions) |
- |
500 |
|
- |
9.1(Dimensions) |
- |
150 |
|
- |
9.1(Dimensions) |
- |
150 |
|
- |
9.1(Dimensions) |
- |
150 |
|
- |
9.1(Dimensions) |
- |
150 |
|
- |
9.1(Dimensions) |
- |
150 |
|
- |
9.1(Dimensions) |
- |
150 |
|
- |
9.1(Dimensions) |
- |
150 |
|
- |
9.1(Dimensions) |
- |
150 |
|
- |
9.1(Dimensions) |
- |
150 |
|
- |
9.1(Dimensions) |
- |
150 |
|
- |
9.1(Dimensions) |
- |
150 |
|
- |
9.1(Dimensions) |
- |
150 |
|
- |
9.1(Dimensions) |
- |
150 |
|
- |
9.1(Dimensions) |
- |
150 |
|
- |
9.1(Dimensions) |
- |
150 |
|
- |
9.1(Dimensions) |
- |
150 |
|
- |
9.1(Dimensions) |
- |
150 |
|
- |
9.1(Dimensions) |
- |
150 |
|
- |
9.1(Dimensions) |
- |
150 |
|
- |
9.1(Dimensions) |
- |
150 |
|
- |
9.1(Dimensions) |
- |
150 |
|
- |
9.1(Dimensions) |
- |
150 |
|
- |
9.1(Dimensions) |
- |
150 |
|
- |
9.1(Dimensions) |
- |
150 |
|
- |
9.2(Dimensions) |
- |
150 |
|
- |
9.3(Dimensions) |
- |
150 |
|
- |
9.3(Dimensions) |
- |
150 |
|
- |
9.3(Dimensions) |
- |
150 |
|
- |
9.3(Dimensions) |
- |
150 |
|
- |
9.3(Dimensions) |
- |
150 |
|
- |
9.3(Dimensions) |
- |
150 |
|
- |
9.3(Dimensions) |
- |
150 |
|
- |
10(Protection against electric shock ) |
- |
1000 |
|
- |
11.1(Terminals) |
- |
125 |
|
- |
11.2(Terminals) |
- |
125 |
|
- |
11.3(Terminals) |
- |
125 |
|
- |
11.3(Terminals) |
- |
125 |
|
- |
11.3(Terminals) |
- |
125 |
|
- |
11.3(Terminals) |
- |
125 |
|
- |
11.3(Terminals) |
- |
125 |
|
- |
11.3(Terminals) |
- |
125 |
|
- |
11.4(Terminals) |
- |
125 |
|
- |
12(Provision for Earthing) |
- |
1000 |
|
- |
13.1(Construction) |
- |
110 |
|
- |
13.1(Construction (Data Sheet No 7005-10)) |
- |
110 |
|
- |
13.1(Construction (Data Sheet No 7005-10& 7006-15A)) |
- |
110 |
|
- |
13.2(Construction (Data Sheet No 7005-10& 7006-15A)) |
- |
110 |
|
- |
13.3(Construction ) |
- |
110 |
|
- |
13.4(Construction ) |
- |
110 |
|
- |
13.5(Construction) |
- |
110 |
|
- |
13.2 ,13.6 & 13.7 (Construction) |
- |
110 |
|
- |
13.2 ,13.6 & 13.8(Construction) |
- |
110 |
|
- |
13.11(Construction) |
- |
110 |
|
- |
14(Construction) |
- |
500 |
|
- |
15.1(Moisture Resistance, Insulation Resistance and Electric Strength) |
- |
700 |
|
- |
15.2(Moisture Resistance, Insulation Resistance and Electric Strength) |
- |
700 |
|
- |
15.3(Moisture Resistance, Insulation Resistance and Electric Strength) |
- |
700 |
|
- |
16.1(Mechanical Strength) |
- |
500 |
|
- |
16.1(Mechanical Strength) |
- |
60 |
|
- |
16.2(Mechanical Strength) |
- |
60 |
|
- |
16.3(Mechanical Strength) |
- |
60 |
|
- |
16.4(Mechanical Strength) |
- |
60 |
|
- |
16.5(Mechanical Strength) |
- |
60 |
|
- |
16.6 & Table - 6(Mechanical Strength) |
- |
60 |
|
- |
16.7(Mechanical Strength) |
- |
60 |
|
- |
16.8(Mechanical Strength) |
- |
60 |
|
- |
17(Screws,current-carrying parts and connections) |
- |
500 |
|
- |
18(Creepage distances and Clearances) |
- |
500 |
|
- |
18.1, Table 8(Creepage distances and Clearances) |
- |
500 |
|
- |
18.1, Table 8(Creepage distances and Clearances) |
- |
500 |
|
- |
18.1, Table 8(Creepage distances and Clearances) |
- |
500 |
|
- |
18.1, Table 8(Creepage distances and Clearances) |
- |
500 |
|
- |
18.1, Table 8(Creepage distances and Clearances) |
- |
500 |
|
- |
18.1, Table 8(Creepage distances and Clearances) |
- |
500 |
|
- |
18.1, Table 8(Creepage distances and Clearances) |
- |
500 |
|
- |
19.1(General resistance to heat) |
- |
375 |
|
- |
19.2(General resistance to heat) |
- |
375 |
|
- |
19.3(General resistance to heat) |
- |
375 |
|
- |
19.4(Resistance to heat test) |
- |
375 |
|
- |
20.1(Resistance to heat, fire and tracking) |
- |
500 |
|
- |
20.3(Resistance to heat, fire and tracking) |
- |
500 |
|
- |
20.4(Resistance to heat, fire and tracking) |
- |
500 |
|
- |
20.5(Resistance to tracking) |
- |
500 |
|
- |
21.1(Resistance to excessive residual stresses and to rusting) |
- |
500 |
|
- |
21.1(Resistance to excessive residual stresses and to rusting) |
- |
500 |
|
- |
6(Rating ) |
- |
400 |
|
- |
6(Rating ) |
- |
400 |
|
- |
7(Classification) |
- |
500 |
|
- |
7.2(Classification) |
- |
100 |
|
- |
7.3(Classification) |
- |
100 |
|
- |
7.4(Classification) |
- |
100 |
|
- |
7.5(Classification) |
- |
100 |
|
- |
7.6(Classification) |
- |
100 |
|
- |
8.1(Marking ) |
- |
500 |
|
- |
8.1(Marking ) |
- |
60 |
|
- |
8.1(Marking ) |
- |
60 |
|
- |
8.1(Marking ) |
- |
60 |
|
- |
8.1(Marking ) |
- |
60 |
|
- |
8.1(Marking ) |
- |
60 |
|
- |
8.1(Marking ) |
- |
60 |
|
- |
8.1(Marking ) |
- |
60 |
|
- |
8.1(Marking ) |
- |
60 |
|
- |
8.1(Marking ) |
- |
60 |
|
- |
8.1(Marking ) |
- |
60 |
|
- |
8.1(Marking ) |
- |
60 |
|
- |
8.2(Marking ) |
- |
60 |
|
- |
8.2(Marking ) |
- |
60 |
|
- |
8.2(Marking ) |
- |
60 |
|
- |
8.3(Marking ) |
- |
60 |
|
- |
8.4(Marking ) |
- |
60 |
|
- |
8.5(Marking ) |
- |
60 |
|
- |
8.6(Marking ) |
- |
60 |
|
- |
8.7(Marking ) |
- |
60 |
|
- |
8.8(Marking ) |
- |
60 |
|
- |
9.1(Dimensions) |
- |
150 |
|
- |
9.1(Dimensions) |
- |
150 |
|
- |
9.1(Dimensions) |
- |
150 |
|
- |
9.1(Dimensions) |
- |
150 |
|
- |
9.1(Dimensions) |
- |
150 |
|
- |
9.1(Dimensions) |
- |
150 |
|
- |
9.1(Dimensions) |
- |
150 |
|
- |
9.1(Dimensions) |
- |
150 |
|
- |
9.1(Dimensions) |
- |
150 |
|
- |
9.1(Dimensions) |
- |
150 |
|
- |
9.1(Dimensions) |
- |
150 |
|
- |
9.1(Dimensions) |
- |
150 |
|
- |
9.1(Dimensions) |
- |
150 |
|
- |
9.1(Dimensions) |
- |
150 |
|
- |
9.1(Dimensions) |
- |
150 |
|
- |
9.1(Dimensions) |
- |
150 |
|
- |
9.1(Dimensions) |
- |
150 |
|
- |
9.1(Dimensions) |
- |
150 |
|
- |
9.1(Dimensions) |
- |
150 |
|
- |
9.1(Dimensions) |
- |
150 |
|
- |
9.1(Dimensions) |
- |
150 |
|
- |
9.1(Dimensions) |
- |
150 |
|
- |
9.1(Dimensions) |
- |
150 |
|
- |
9.1(Dimensions) |
- |
150 |
|
- |
9.2(Dimensions) |
- |
150 |
|
- |
9.3(Dimensions) |
- |
150 |
|
- |
9.3(Dimensions) |
- |
150 |
|
- |
9.3(Dimensions) |
- |
150 |
|
- |
9.3(Dimensions) |
- |
150 |
|
- |
9.3(Dimensions) |
- |
150 |
|
- |
9.3(Dimensions) |
- |
150 |
|
- |
10(Protection against electric shock ) |
- |
1000 |
|
- |
11.1(Terminals) |
- |
125 |
|
- |
11.2(Terminals) |
- |
125 |
|
- |
11.3(Terminals) |
- |
125 |
|
- |
12.3(Terminals) |
- |
125 |
|
- |
11.3(Terminals) |
- |
125 |
|
- |
11.3(Terminals) |
- |
125 |
|
- |
11.3(Terminals) |
- |
125 |
|
- |
11.4(Terminals) |
- |
125 |
|
- |
13.1(Construction) |
- |
110 |
|
- |
13.1(Construction (Data Sheet No 7005-10)) |
- |
110 |
|
- |
13.1(Construction (Data Sheet No 7005-10& 7006-15A)) |
- |
100 |
|
- |
13.2(Construction (Data Sheet No 7005-10& 7006-15A)) |
- |
110 |
|
- |
13.3(Construction ) |
- |
110 |
|
- |
13.4(Construction ) |
- |
110 |
|
- |
13.5(Construction) |
- |
110 |
|
- |
13.2 ,13.6 & 13.7 (Construction) |
- |
110 |
|
- |
13.2 ,13.6 & 13.8(Construction) |
- |
110 |
|
- |
13.11(Construction) |
- |
110 |
|
* |
14(Construction) |
- |
500 |
|
- |
15.1(Moisture Resistance, Insulation Resistance and Electric Strength) |
- |
700 |
|
- |
15.3(Moisture Resistance, Insulation Resistance and Electric Strength) |
- |
700 |
|
- |
16.1(Mechanical Strength) |
- |
60 |
|
- |
16.2(Mechanical Strength) |
- |
60 |
|
- |
16.4(Mechanical Strength) |
- |
60 |
|
- |
16.5(Mechanical Strength) |
- |
60 |
|
- |
16.6 & Table - 6(Mechanical Strength) |
- |
60 |
|
- |
16.7(Mechanical Strength) |
- |
60 |
|
- |
16.8(Mechanical Strength) |
- |
60 |
|
- |
17(Screws,current-carrying parts and connections) |
- |
500 |
|
- |
18(Creepage distances and Clearances) |
- |
500 |
|
- |
18(Creepage distances and Clearances) |
- |
500 |
|
- |
18(Creepage distances and Clearances) |
- |
500 |
|
- |
18(Creepage distances and Clearances) |
- |
500 |
|
- |
18(Creepage distances and Clearances) |
- |
500 |
|
- |
18(Creepage distances and Clearances) |
- |
500 |
|
- |
18(Creepage distances and Clearances) |
- |
500 |
|
- |
18(Creepage distances and Clearances) |
- |
500 |
|
- |
19.1(General resistance to heat) |
- |
375 |
|
- |
19.2(General resistance to heat) |
- |
375 |
|
- |
19.3(General resistance to heat) |
- |
375 |
|
- |
19.4(Resistance to heat test) |
- |
500 |
|
- |
20.1(Resistance to heat, fire and tracking) |
- |
500 |
|
- |
20.3(Resistance to heat, fire and tracking) |
- |
500 |
|
- |
20.4(Resistance to heat, fire and tracking) |
- |
500 |
|
- |
20.5(Resistance to tracking) |
- |
500 |
|
- |
21.1(Resistance to excessive residual stresses and to rusting) |
- |
500 |
|
- |
21.1(Resistance to excessive residual stresses and to rusting) |
- |
500 |
|
- |
|
Complete
|
|
23 Jun, 2025 |
- |
23 |
IS 555 (1979) |
Specification for electric table type fans and regulators (Third Revision) |
-
|
15000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
3.0(Size, Speed and Types) |
- |
300 |
|
- |
4.0(Rated Voltages) |
- |
400 |
|
- |
5.0(Rated Frequency) |
- |
1000 |
|
- |
6.0(Design and General Construction) |
- |
300 |
|
- |
7.8(Speed Regulators) |
- |
200 |
|
- |
7.9(Interchangeability) |
- |
300 |
|
- |
7.11(Oscillating Mechanism) |
- |
500 |
|
- |
9.0(Marking) |
- |
300 |
|
- |
10.3(Air Delivery Test) |
- |
1700 |
|
- |
10.4(Temperature-Rise Test) |
- |
1000 |
|
- |
10.5(Leakage Current) |
- |
800 |
|
- |
10.6(High Voltage Test) |
- |
1300 |
|
- |
10.7(Insulation-Resistance Test (Shall follow Moisture Resistance Test Cl.10.12)) |
- |
900 |
|
- |
10.8(Construction) |
- |
900 |
|
- |
10.9(Fan Speed and Input) |
- |
400 |
|
- |
10.1(Earthing Connection) |
- |
800 |
|
- |
10.11(Protection against Electric Shock) |
- |
500 |
|
- |
10.12(Moisture Resistance Test) |
- |
1500 |
|
- |
10.13, 7.4(Mechanical Endurance Test (for Regulators Only)) |
- |
1100 |
|
- |
10.14(Cord Grip Test) |
- |
400 |
|
- |
10.16(Creepage Distances and Clearances) |
- |
400 |
|
- |
|
Complete
|
|
23 Jun, 2025 |
- |
24 |
IS 11037 (2019) |
Electronic Type Fan Regulators — Specification ( First Revision ) |
-
|
36000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
9.1 (a)(Marking ) |
- |
83 |
|
- |
9.1 (b)(Marking ) |
- |
83 |
|
- |
9.1 (c)(Marking ) |
- |
83 |
|
- |
9.1 (d)(Marking ) |
- |
83 |
|
- |
9.1 (e)(Marking ) |
- |
83 |
|
- |
9.1 (f)(Marking ) |
- |
83 |
|
- |
9.2(Marking ) |
- |
500 |
|
- |
6.1(Design and General Construction) |
- |
200 |
|
- |
6.2(Design and General Construction) |
- |
200 |
|
- |
6.3(Design and General Construction) |
- |
200 |
|
- |
6.5(Design and General Construction) |
- |
200 |
|
- |
6.6(Design and General Construction) |
- |
200 |
|
- |
9.5.1 , 7.3(Temperature Rise) |
- |
1500 |
|
- |
9.5.1 , 7.3 (a)(Temperature Rise ) |
- |
750 |
|
- |
9.5.1 , 7.3 (b)(Temperature Rise) |
- |
750 |
|
- |
9.5.1 , 7.3 (b)(Temperature Rise) |
- |
750 |
|
- |
9.5.1 , 7.3 (b)(Temperature Rise) |
- |
750 |
|
- |
9.5.2, 7.2(Leakage Current Test(as per Cl.13.2 of IS 302 (Part 1).) |
- |
1000 |
|
- |
9.5.3(High Voltage Test) |
- |
1500 |
|
- |
9.5.5(Earthing Connection) |
- |
1000 |
|
- |
9.5.6(Protection against electric shock (as per Cl.8 of IS 302 (Part 1)) |
- |
1000 |
|
- |
7.6(General and safety requirements) |
- |
1000 |
|
- |
7.7(Voltage drop) |
- |
1100 |
|
- |
8.1(Performance) |
- |
300 |
|
- |
8.2(Performance) |
- |
300 |
|
- |
8.3(Performance) |
- |
300 |
|
- |
9.5.7, 9.5.4(Moisture Resistance ) |
- |
2500 |
|
- |
7.4.1(a)(Mechanical strength ) |
- |
500 |
|
- |
7.4.1(b)(Mechanical strength ) |
- |
500 |
|
- |
9.5.8, (Mechanical strength (as per Cl.21.1 of IS 302-1:2008)) |
- |
1500 |
|
- |
9.5.9, 7.5, Table-1(Creepage Distances and Clearances (as per Cl. 29 of IS 302-1)) |
- |
1000 |
|
- |
9.5.9, 7.5, Table-1(Creepage Distances and Clearances (as per Cl. 29 of IS 302-1)) |
- |
1000 |
|
- |
9.5.10( Electrical Endurance Test) |
- |
3000 |
|
- |
9.5.11.2(Environmental Tests) |
- |
5000 |
|
- |
9.5.11.3(Environmental Tests) |
- |
3000 |
|
- |
9.5.11.4(Environmental Tests) |
- |
4000 |
|
- |
9.5.12(Resistance to Abnormal Heat and to Fire) |
- |
750 |
|
- |
9.5.12.1(Resistance to Abnormal Heat and to Fire) |
- |
750 |
|
- |
9.5.13(Resistance to Rusting ) |
- |
1500 |
|
- |
9.5.14(Checking of Dimensions) |
- |
1500 |
|
- |
9.1(Marking ) |
- |
500 |
|
- |
9.1 (a)(Marking ) |
- |
83 |
|
- |
9.1 (b)(Marking ) |
- |
83 |
|
- |
9.1 (c)(Marking ) |
- |
83 |
|
- |
9.1 (d)(Marking ) |
- |
83 |
|
- |
9.1 (e)(Marking ) |
- |
83 |
|
- |
9.1 (f)(Marking ) |
- |
83 |
|
- |
9.2(Marking ) |
- |
83 |
|
- |
6.1(Design and General Construction) |
- |
200 |
|
- |
6.2(Design and General Construction) |
- |
200 |
|
- |
6.3(Design and General Construction) |
- |
200 |
|
- |
6.5(Design and General Construction) |
- |
200 |
|
- |
6.6(Design and General Construction) |
- |
200 |
|
- |
9.5.1 , 7.3(Temperature Rise) |
- |
1500 |
|
- |
9.5.1 , 7.3 (a)(Temperature Rise ) |
- |
750 |
|
- |
9.5.1 , 7.3 (b)(Temperature Rise) |
- |
750 |
|
- |
9.5.1 , 7.3 (b)(Temperature Rise) |
- |
750 |
|
- |
9.5.1 , 7.3 (b)(Temperature Rise) |
- |
750 |
|
- |
9.5.2, 7.2(Leakage Current Test(as per Cl.13.2 of IS 302 (Part 1).) |
- |
1000 |
|
- |
9.5.5(Earthing Connection) |
- |
1000 |
|
- |
9.5.6(Protection against electric shock (as per Cl.8 of IS 302 (Part 1)) |
- |
1000 |
|
- |
7.6(General and safety requirements) |
- |
1000 |
|
- |
8.1(Performance) |
- |
300 |
|
- |
8.2(Performance) |
- |
300 |
|
- |
8.3(Performance) |
- |
300 |
|
- |
9.5.7, 9.5.4(Moisture Resistance ) |
- |
2500 |
|
- |
7.4.1(Mechanical strength ) |
- |
1000 |
|
- |
7.4.1(a)(Mechanical strength ) |
- |
500 |
|
- |
7.4.1(b)(Mechanical strength ) |
- |
500 |
|
- |
9.5.8, (Mechanical strength (as per Cl.21.1 of IS 302-1:2008)) |
- |
1500 |
|
- |
9.5.9, 7.5, Table-1(Creepage Distances and Clearances (as per Cl. 29 of IS 302-1)) |
- |
1000 |
|
- |
9.5.9, 7.5, Table-1(Creepage Distances and Clearances (as per Cl. 29 of IS 302-1)) |
- |
1000 |
|
- |
9.5.10( Electrical Endurance Test) |
- |
3000 |
|
- |
9.5.11.3(Environmental Tests) |
- |
3000 |
|
- |
9.5.11.4(Environmental Tests) |
- |
4000 |
|
- |
9.5.12(Resistance to Abnormal Heat and to Fire) |
- |
750 |
|
- |
9.5.12.1(Resistance to Abnormal Heat and to Fire) |
- |
750 |
|
- |
9.5.13(Resistance to Rusting ) |
- |
1500 |
|
- |
|
Complete
|
|
23 Jun, 2025 |
- |
25 |
IS 11328 (1985) |
Specification for self - Contained automatic ice makers |
-
|
25000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
5.5.1(Pressure Test
and leakage tests) |
- |
5500 |
|
- |
5.5.2(Insulation resistance
test) |
- |
6250 |
|
- |
5.5.3(High voltage test) |
- |
5000 |
|
- |
5.5.4(Ice making capacity rating test) |
- |
8250 |
|
- |
|
Complete
|
|
23 Jun, 2025 |
- |
26 |
IS 15750 (2006) |
Household frost - Free refrigerating appliances - Refrigerators cooled by internal forced air circulation - Characteristics and test methods - Specification |
-
|
150000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
3.3(General Definitions) |
- |
500 |
|
- |
4(Material Design & manufacturing) |
- |
600 |
|
- |
5(Required characteristics) |
- |
500 |
|
- |
6(Determination of linear dimensions, volumes and areas) |
- |
15000 |
|
- |
7(General test condition) |
- |
600 |
|
- |
8(Testing the air tightness of Door or Lid Seal) |
- |
7000 |
|
- |
9(Testing the opening force of door(s) or lid(s)) |
- |
3500 |
|
- |
10(Testing the durability of hinges and handles of door(s) and lid(s)) |
- |
3500 |
|
- |
11(Testing the mechanical
strength of shelves
and similar components) |
- |
7000 |
|
- |
12(Testing the storage temperatures) |
- |
10000 |
|
- |
13(Water vapour condensation test ) |
- |
7000 |
|
- |
14(Energy consumption test) |
- |
40000 |
|
- |
15(Temperature Rise Test) |
- |
10000 |
|
- |
16(Pull down test) |
- |
25000 |
|
- |
17(Ice making test) |
- |
5000 |
|
- |
18(Test for absence of
odour & taste) |
- |
3000 |
|
- |
19(High voltage test) |
- |
3000 |
|
- |
20(Insulation resistance test) |
- |
3000 |
|
- |
22(Requirement of ECO mark) |
- |
4600 |
|
- |
23(Designation) |
- |
600 |
|
- |
24(Marking) |
- |
600 |
|
- |
|
Complete
|
|
23 Jun, 2025 |
- |
27 |
IS 1476 : Part 1 (2000) |
Performance of household refrigerating appliance - Refrigerators with or without low temperature compartment: Part 1 energy consumption and performance (Third Revision) |
-
|
135000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
4(Classification) |
- |
500 |
|
- |
5(Material Design & Manufacture) |
- |
3000 |
|
- |
6(Electrical Components) |
- |
2500 |
|
- |
7.1(Dimensional characteristics) |
- |
250 |
|
- |
7.2(Performance Characteristics) |
- |
250 |
|
- |
8(Determination of Linear dimensions, volumes & areas.) |
- |
12000 |
|
- |
9(Operational requirement) |
- |
500 |
|
- |
11( Additional Requirement for ECO mark) |
- |
500 |
|
- |
13(Measurement) |
- |
500 |
|
- |
14.1(Door Seal Test) |
- |
5000 |
|
- |
14.2(Mechanical strength of shelves & similar components) |
- |
6000 |
|
- |
14.3(Doors and fitting test) |
- |
5000 |
|
- |
14.4(No load adjustment test) |
- |
10000 |
|
- |
14.5(No-load performance Test) |
- |
22000 |
|
- |
14.6(Ice making test) |
- |
13000 |
|
- |
14.7(Thermal Insulation Test) |
- |
5500 |
|
- |
14.8(High voltage test) |
- |
5000 |
|
- |
14.9(Rated Energy consumption test) |
- |
34500 |
|
- |
15.1(Thermostat Test) |
- |
5000 |
|
- |
15.2(Insulation resistance) |
- |
4000 |
|
- |
|
Complete
|
|
23 Jun, 2025 |
- |
28 |
IS 1474 (1959) |
Specification for commercial refrigerators |
-
|
285000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
3.3.1(Gross Volume) |
- |
7000 |
|
- |
3.3(Volume of evaporator space) |
- |
7000 |
|
- |
3.5(Volume of fixed shelves and partitions) |
- |
7000 |
|
- |
3.6(Computation of shelf area) |
- |
7000 |
|
- |
3.7(Net volume) |
- |
7000 |
|
- |
7.5.1(Pressure Test) |
- |
35000 |
|
- |
7.5.7(Test for Adequate Rating of Compressor Motor) |
- |
25000 |
|
- |
7.5.6(Rating Test) |
- |
40000 |
|
- |
7.5.5(Condensation Test) |
- |
50000 |
|
- |
7.5.4(Thermal Insulation Test) |
- |
25000 |
|
- |
7.5.3(Insulation Resistance Test (Assembly Test)) |
- |
40000 |
|
- |
7.5.8(Door Seal Test) |
- |
35000 |
|
- |
|
Complete
|
|
23 Jun, 2025 |
- |
29 |
IS 1287 (1993) |
Electric toasters - Specification (Third Revision) |
-
|
38000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
6(Rating) |
- |
600 |
|
- |
7(Classification) |
- |
650 |
|
- |
8(Marking) |
- |
750 |
|
- |
9(Safety Requirements) |
- |
0 |
|
- |
11(Overall dimension) |
- |
1500 |
|
- |
12(Length of the Flexible cord) |
- |
750 |
|
- |
13(Mass) |
- |
750 |
|
- |
14(Number and Dimensions of the toasing chambers, toasting surfaces and heating elements) |
- |
5000 |
|
- |
15(Force necessary to operate the bread carriage) |
- |
5000 |
|
- |
16(Preparation of bread for toasters) |
- |
1000 |
|
- |
17(Browning control setting) |
- |
5000 |
|
- |
18(Toasting) |
- |
2000 |
|
- |
19(Toasting time) |
- |
2000 |
|
- |
20(Evenness of Browning) |
- |
3000 |
|
- |
21(Browning control characteristic) |
- |
3000 |
|
- |
22(Endurance) |
- |
5000 |
|
- |
23(Finish) |
- |
1000 |
|
- |
24(Functional Provision) |
- |
1000 |
|
- |
|
Complete
|
|
23 Jun, 2025 |
- |
30 |
IS/IEC 61730 : PART 1 (2004) |
Photovoltaic (PV) Module Safety Qualification Part 1 Requirements for Construction |
-
|
460000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
3(Application classes) |
- |
20000 |
|
- |
4(Construction requirements) |
- |
20000 |
|
- |
5(Polymeric materials) |
- |
45000 |
|
- |
6(Internal wiring and current-carrying parts) |
- |
45000 |
|
- |
7(Connections) |
- |
95000 |
|
- |
8(Bonding and grounding) |
- |
35000 |
|
- |
9(Creepage and clearance distances) |
- |
35000 |
|
- |
10(Field wiring compartments with covers) |
- |
60000 |
|
- |
11(Marking) |
- |
15000 |
|
- |
12() |
- |
40500 |
|
- |
|
Complete
|
|
23 Jun, 2025 |
- |