31 |
IS 13592 (2013) |
Unplasticized Polyvinyl Chloride (PVC-U) Pipes for Soil and Waste Discharge System Inside and Outside Buiildings Including Ventilation and Rainwater System |
All Grade |
-
|
18000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
Cl.5(Surface colour of the pipes shall be dark shade of grey) |
- |
500 |
|
10% Discount for BIS |
Cl.7.1(Mean outside diameter, outside diameter at any point
for Type A and Type B pipes
manufactured plain or with socket shall be as given in
Table 1. Dimensions shall be measured according to
the method given in IS 12235 (Part 1).) |
- |
500 |
|
10% Discount for BIS |
Cl.7.1( wall thickness at any point
for Type A and Type B pipes
manufactured plain or with socket shall be as given in
Table 1. Dimensions shall be measured according to
the method given in IS 12235 (Part 1).) |
- |
500 |
|
10% Discount for BIS |
Cl.7.2(Pipes shall be supplied in nominal lengths of 2, 3, 4 or
6 metres either plain or with socket for solvent
cementing/grooved socket. Tolerances on specified
length shall be + 10 mm and – 0 mm.The nominal length of the pipe with socket for solvent
cementing/grooved socket shall be as given in Fig. 1.) |
- |
500 |
|
10% Discount for BIS |
Cl.7.3.1(Minimum wall thickness of socket on pipes shall
be as given in Table 2 read with Fig. 2 and Fig. 3.) |
- |
500 |
|
10% Discount for BIS |
Cl.7.3.2(Dimensions of sockets for solvent cementing and
grooved sockets of pipes shall be as given in Tables 3
and 4 respectively, read with Fig. 2 and 3.) |
- |
500 |
|
10% Discount for BIS |
Cl.8.1(The internal and external surface of the pipes shall be
smooth and clean, and free from grooving and other
defects. The end shall be clearly cut and shall be square
with the axis of the pipe. The end may be chamfered
on the plain side.) |
- |
500 |
|
10% Discount for BIS |
Cl.8.2(When tested by the method described in IS 12235
(Part 5), a length of pipe sample of 200 ± 20 mm shall
not alter in length by more than 5 percent. In the case
of socket ended pipes, this test shall be carried out on
the plain portion of pipe taken at least 100 mm away
from the root of the socket.) |
- |
500 |
|
10% Discount for BIS |
Cl8.3(This test shall be carried out for socket end pipes only.
When tested by the method described in IS 12235
(Part 6), the test specimens shall not show blisters,
excessive delamination or cracking or signs of weld
line splitting.) |
- |
500 |
|
10% Discount for BIS |
Cl.8.4(When determined in accordance with IS 12235 (Part 2),
the vicat softening temperature of the specimen shall
not be less than 79°C.) |
- |
500 |
|
10% Discount for BIS |
Cl.8.5(After the required
period of exposure, the tensile strengths of two samples when tested as per IS 12235 (Part 13) shall not show
difference of more than 20 percent of their initial tensile
strengths) |
- |
500 |
|
10% Discount for BIS |
Cl. 9, IS 12235 Part 7(Resistance to Sulphuric Acid) |
- |
500 |
|
10% Discount for BIS |
Cl.10.1(When tested by method prescribed in IS 12235 (Part 9),the pipe shall have a true impact rate of not more than
10 percent. Mass of striker and height of fall shall be
as per Annex A.) |
- |
500 |
|
10% Discount for BIS |
Cl.10.2(When determined in accordance with the method
described in IS 12235 (Part 13), the tensile strength at
break shall not be less than 45 MPa.) |
- |
500 |
|
10% Discount for BIS |
Cl.10.3(The axial shrinkage shall not exceed 2 percent when
determined in accordance with Annex B.) |
- |
500 |
|
10% Discount for BIS |
Cl.11.(Jointing of solvent
cementing joints is to be carried out using solvent
conforming to IS 14182.
Apply a pressure of 0.05 MPa for a period of 15 min
and there should be no leakage at any joint.) |
- |
500 |
|
10% Discount for BIS |
Cl. 12, IS 12235 Part 11(Resistance to Di-Chloro-Methane ) |
- |
4000 |
|
(10% Discount for BIS) |
Cl6.3(The composition shall be based on PVC resin
having a K-value of 64 or greater when tested in
accordance with IS 4669) |
- |
1000 |
|
(10% Discount for BIS) |
|
Complete
|
|
- |
- |
32 |
IS 13395 (1995) |
Performance of handles and handle assemblies attached to cookware - Specification |
All Grade |
-
|
7450 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
5.2(Bending Strength) |
- |
750 |
|
(10% Discount for BIS) |
5.3(Torque Strength) |
- |
750 |
|
(10% Discount for BIS) |
5.4(Impact Strength) |
- |
750 |
|
(10% Discount for BIS) |
5.5(Fatigue Resistance) |
- |
750 |
|
(10% Discount for BIS) |
5.6(Leakage) |
- |
750 |
|
(10% Discount for BIS) |
5.7(Thermal Insulation) |
- |
1000 |
|
(10% Discount for BIS) |
5.8(Heat Resistance) |
- |
750 |
|
(10% Discount for BIS) |
5.9(Washing Resistance) |
- |
1000 |
|
(10% Discount for BIS) |
5.1(Burning Resistance) |
- |
750 |
|
(10% Discount for BIS) |
|
Complete
|
|
- |
- |
33 |
IS 12823 (2015) |
Prelaminated Particle Boards from Wood and other Lignocellulosic Material - Specification ( First Revision ) |
All Grade |
-
|
11700 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
Cl 10.2(Test For Density) |
- |
500 |
|
(10% Discount for BIS) |
Cl 10.3(Test For Moisture Content) |
- |
500 |
|
(10% Discount for BIS) |
Cl 10.4(For Water AbsorptionTest ) |
- |
600 |
|
(10% Discount for BIS) |
Cl 10.5(For Swelling in water Test ) |
- |
300 |
|
(10% Discount for BIS) |
Cl 10.6(Tesr For Modulus Of Elasticity & Mudulus Of Rupture) |
- |
1500 |
|
(10% Discount for BIS) |
Cl 10.7(For Determination of Tensile Strength Perpendicular to Surface) |
- |
1000 |
|
(10% Discount for BIS) |
Cl 10.8(For Determination of Tensile Strength Perpendicular to Surface After Ageing Test) |
- |
1500 |
|
(10% Discount for BIS) |
Cl 10.9(Test For Screw Withdrawal Strength) |
- |
600 |
|
(10% Discount for BIS) |
Cl 10.10 & Annex C( Test For Abrasion Resistance) |
- |
600 |
|
(10% Discount for BIS) |
Cl 10.11 & Annex D( Test For Resistance to Steam) |
- |
600 |
|
(10% Discount for BIS) |
Cl 10.12 & Annex E( Test For Crack Resistance) |
- |
600 |
|
(10% Discount for BIS) |
Cl 10.13 & Annex F( Test For Resistance to Cigarette Burn) |
- |
600 |
|
(10% Discount for BIS) |
|
Complete
|
|
- |
- |
34 |
IS 12786 (1989) |
Irrigation equipment - Polyethylene pipes for irrigation laterals - Specification |
All Grade |
-
|
7500 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
5.0
5.1
(Table1)
(Dimensions a)Outside diameter of pipe) |
- |
250 |
|
(10% Discount for BIS) |
7.1
Table-2
(Hydraulic Characteristics
a)Quality Test for 100 hours at 70°C & 2.5.MPa induced stress.
) |
- |
4000 |
|
(10% Discount for BIS) |
7.1
Table-2
(b)Acceptance Test for 01 hour at 20°C & 6.9MPa induced stress) |
- |
1000 |
|
(10% Discount for BIS) |
7.2(Reversion Test) |
- |
500 |
|
(10% Discount for BIS) |
7.3(Tensile Test) |
- |
1000 |
|
(10% Discount for BIS) |
7.4(SusceptibiIity to Environmental Stress
Cracking) |
- |
4000 |
|
(10% Discount for BIS) |
6.0
(6.1)
(Visual appearance) |
- |
250 |
|
(10% Discount for BIS) |
4.1.c.ii (Toluene extract - Annex A) |
- |
500 |
|
(10% Discount for BIS) |
4.1.c.iii (Volatile matter - Annex B ) |
- |
300 |
|
(10% Discount for BIS) |
4.1.c & 4.2.a (Carbon Black content - IS 2530 : 1963) |
- |
1000 |
|
(10% Discount for BIS) |
4.2.b (The dispersion of Carbon Black content shall be satisfactory - IS 2530 : 1963) |
- |
1000 |
|
(10% Discount for BIS) |
|
Complete
|
|
- |
- |
35 |
IS 12701 (1996) |
Rotational moulded polyethylene water storage tanks - specification (First Revision) |
All Grade |
-
|
15000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
4.2.3(Carbon Black Content ) |
- |
1000 |
|
(10% Discount for BIS) |
4.2.3(Carbon Dispersion Test) |
- |
1000 |
|
(10% Discount for BIS) |
5.1 Table 1(Dimensioas of Cylinderical Vertical Tank) |
- |
200 |
|
(10% Discount for BIS) |
5.2 Table 2(Dimensions of Rectangular Loft Tanks) |
- |
200 |
|
(10% Discount for BIS) |
7.1.1(Resistance to Deformation) |
- |
1000 |
|
(10% Discount for BIS) |
7.2(Resistance to Impact) |
- |
1000 |
|
(10% Discount for BIS) |
7.3(Test for Top Load Resistance) |
- |
1000 |
|
(10% Discount for BIS) |
7.4(Tensile Strength) |
- |
1000 |
|
(10% Discount for BIS) |
7.5(Flexural Modulus) |
- |
1000 |
|
(10% Discount for BIS) |
7.6(overall Migration) |
- |
7600 |
|
(10% Discount for BIS) |
9.1(Lid Thickness) |
- |
100 |
|
(10% Discount for BIS) |
9.2.1(Man-Hole and Hand-Hole Lids) |
- |
100 |
|
(10% Discount for BIS) |
6.1(Finish) |
- |
150 |
|
(10% Discount for BIS) |
5.4(Wall Thickness above effective height) |
- |
100 |
|
(10% Discount for BIS) |
|
Complete
|
|
- |
- |
36 |
IS 12406 (2003) |
Medium density fibre boards for general purpose - Specification (First Revision) |
All Grade |
-
|
8900 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
Cl 8(Dimensions & Tolerances) |
- |
500 |
|
(10% Discount for BIS) |
Cl 11.4(Test For Density) |
- |
300 |
|
(10% Discount for BIS) |
Cl 11.5(Test For Moisture Content) |
- |
500 |
|
(10% Discount for BIS) |
Cl 11.6(Test For water Absorption) |
- |
500 |
|
(10% Discount for BIS) |
Cl 11.8(Tesr For Modulus Of Elasticity & Mudulus Of Rupture) |
- |
1500 |
|
(10% Discount for BIS) |
Cl 11.9(Test For Internal Bond) |
- |
1500 |
|
(10% Discount for BIS) |
Cl 11.10(Test For Screw Withdrawal Strength) |
- |
1500 |
|
(10% Discount for BIS) |
|
Complete
|
|
- |
- |
37 |
IS 11513 (2017) |
Hot rolled carbon steel strip for cold rolling purposes - Specification (Second Revision) |
All Grade |
-
|
4600 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
Cl 8(Workmanship) |
- |
500 |
|
- |
Cl 9(Length, Width, Thickness, Crown, Edge Camber & Difference in Thickness Across Width ) |
- |
500 |
|
- |
|
Complete
|
|
- |
- |
38 |
IS 10748 (2004) |
Hot - Rolled steel strip for welded tubes and pipes - Specification (Second Revision) |
All Grade |
-
|
5600 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
Table 1 ( Clauses 7.1 ,7.2 )( CARBON) |
- |
200 |
|
(10% Discount for BIS) |
Table 1 ( Clauses 7.1 ,7.2 )(SULPHUR) |
- |
200 |
|
(10% Discount for BIS) |
Table 1 ( Clauses 7.1 ,7.2 )(PHOSPHURS) |
- |
200 |
|
(10% Discount for BIS) |
Table 1 ( Clauses 7.1 ,7.2 )(MANGANESE) |
- |
200 |
|
(10% Discount for BIS) |
Table 1 ( Clauses 7.1 ,7.2 )(SILICON) |
- |
200 |
|
(10% Discount for BIS) |
Table 1 ( Clauses 7.1 ,7.2 )(Chromium) |
- |
200 |
|
(10% Discount for BIS) |
Table 1 ( Clauses 7.1 ,7.2 )(Nickel) |
- |
200 |
|
(10% Discount for BIS) |
Table 1 ( Clauses 7.1 ,7.2 )(Molybdenum) |
- |
200 |
|
(10% Discount for BIS) |
7.1( Copper %) |
- |
200 |
|
(10% Discount for BIS) |
Table 1 ( Clauses 7.1 ,7.2 )(NITROGEN) |
- |
200 |
|
(10% Discount for BIS) |
Table 1 ( Clauses 7.1 ,7.2 )(VANADIUM) |
- |
200 |
|
(10% Discount for BIS) |
Table 1 ( Clauses 7.1 ,7.2 )(TITANIUM) |
- |
200 |
|
(10% Discount for BIS) |
Table 1 ( Clauses 7.1 ,7.2 )(NIOBIUM) |
- |
200 |
|
(10% Discount for BIS) |
Cl 8 & Table 3(UTM) |
- |
200 |
|
(10% Discount for BIS) |
Cl 9(Press) |
- |
200 |
|
(10% Discount for BIS) |
Cl 11(Workmanship) |
- |
200 |
|
(10% Discount for BIS) |
Cl 12 & 13(Length, Width & Thickness) |
- |
1000 |
|
(10% Discount for BIS) |
|
Complete
|
|
- |
- |
39 |
IS 10124 : Part 1 (2009) |
Fabricated PVC-U Fittings for Potable Water Supplies - Specification Part 1 General Requirements (Second Revision) |
Upto 315mm All Classes |
-
|
5000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
5.1 Table-1 Fig.1(Dimension of Socket length) |
- |
750 |
|
(10% Discount for BIS) |
5.1.2 Table-1(Dimensions of mean inside diameter at mid-point of socket depth) |
- |
750 |
|
(10% Discount for BIS) |
6.1(Opacity test in accordance with IS 12235 (Part 3)) |
- |
1000 |
|
(10% Discount for BIS) |
6.2(Short Term Hydraulic Test in accordance with Annex A) |
- |
2500 |
|
(10% Discount for BIS) |
|
Complete
|
|
- |
- |
40 |
IS 9968 : Part 1 (1988) |
Specification for elastomer insulatedcables: Part 1 for working voltages up to and including 1100 volts (First Revision) |
All Grade |
-
|
10100 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
21. (b)(Annealing Test (for coper)) |
- |
500 |
|
(10% Discount for BIS) |
21. (c)( Tensile Test (for aluminium)) |
- |
500 |
|
(10% Discount for BIS) |
21. (e)(Conductor Resistance ) |
- |
600 |
|
(10% Discount for BIS) |
21. (a)(Persulphate tests (for copper)) |
- |
500 |
|
(10% Discount for BIS) |
22.1( Elongation) |
- |
500 |
|
(10% Discount for BIS) |
21.1(type test : Ageing In air oven) |
- |
500 |
|
(10% Discount for BIS) |
21.1(type test : Ageing in air bomb) |
- |
500 |
|
(10% Discount for BIS) |
21.1(type test : Ageing In oxygen
bomb) |
- |
500 |
|
(10% Discount for BIS) |
3.1( Copper Cooduetor) |
- |
200 |
|
(10% Discount for BIS) |
3.2(Aluminium conductor) |
- |
200 |
|
(10% Discount for BIS) |
4.3(INSULATION : Silicone Rubber Insulation) |
- |
200 |
|
(10% Discount for BIS) |
5.1(TAPE : Proofed Tape) |
- |
200 |
|
(10% Discount for BIS) |
5.2(TAPE : 2 Polyethyl_ Terephthalate ( PETP ) Tape or
Plastic: Tape or Any Other SlIIitable Tape ) |
- |
200 |
|
(10% Discount for BIS) |
5.3(TAPE : Giass Tape) |
- |
200 |
|
(10% Discount for BIS) |
6.1(FILLERS : ) |
- |
200 |
|
(10% Discount for BIS) |
7.1(BRAID : Textile Braid) |
- |
200 |
|
(10% Discount for BIS) |
7.2(BRAID : Glass Braid ) |
- |
200 |
|
(10% Discount for BIS) |
8.1(SHEATH : General Service Insulated Cables and Flexible
Cords) |
- |
200 |
|
(10% Discount for BIS) |
8.2(SHEATH :Heat Resisting Insulated Cables) |
- |
200 |
|
(10% Discount for BIS) |
9.1(PresenRtive Compound) |
- |
200 |
|
(10% Discount for BIS) |
9.2(Varnish) |
- |
200 |
|
(10% Discount for BIS) |
10( Conductor ) |
- |
200 |
|
(10% Discount for BIS) |
11(Separator tape) |
- |
200 |
|
(10% Discount for BIS) |
12.2(Insulation : Thickness of Insufatien) |
- |
200 |
|
(10% Discount for BIS) |
12.4(Insulation : Allplication of Insulation) |
- |
200 |
|
(10% Discount for BIS) |
13(CORE IDENTiFICATlON) |
- |
200 |
|
(10% Discount for BIS) |
14(Tape) |
- |
200 |
|
(10% Discount for BIS) |
15(BRAIDING) |
- |
200 |
|
(10% Discount for BIS) |
16(COMPOUNDING AND VARNISHING) |
- |
200 |
|
(10% Discount for BIS) |
17(LAYING UP OF CORES) |
- |
200 |
|
(10% Discount for BIS) |
18( Binder tape) |
- |
200 |
|
(10% Discount for BIS) |
19.2(Sheath : Thickness of Sheath) |
- |
200 |
|
(10% Discount for BIS) |
19.4( Sheath :Colour) |
- |
200 |
|
(10% Discount for BIS) |
20( Overall diameter) |
- |
200 |
|
(10% Discount for BIS) |
21.1( Tensile strength ) |
- |
200 |
|
(10% Discount for BIS) |
21.1(type test : Hot set elongation) |
- |
200 |
|
(10% Discount for BIS) |
21.1(type test : Tear resistance ) |
- |
200 |
|
(10% Discount for BIS) |
22.2(type test :Insulauon resistance High voltage (water immersron ) test) |
- |
200 |
|
(10% Discount for BIS) |
22.2(type test : Flammability test
( applicable to cables
finished With SE 3 and
SE 4 sheaths only)
) |
- |
200 |
|
(10% Discount for BIS) |
21(Water absorption test) |
- |
200 |
|
(10% Discount for BIS) |
23(identification) |
- |
200 |
|
(10% Discount for BIS) |
|
Complete
|
|
- |
- |
41 |
IS 9537 : Part 3 (1983) |
Specification for conduits for electrical installations: Part 3 rigid plain conduits of insulating meterials |
All Grade |
-
|
4950 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
9.2(Bending Test i) At Room Temp ii) At Low Temp (-5 ±2°C)) |
- |
500 |
|
(10% Discount for BIS) |
9.3(Compression Test as per caluse 9.3 of IS: 9537 (Part 1)-1980) |
- |
500 |
|
(10% Discount for BIS) |
9.4(Impact Test as per clause 9.4 of IS: 9537 (Part 1)-1980) |
- |
500 |
|
(10% Discount for BIS) |
9.5(Collapse Test as per clause 9.5 of IS: 9537 (Part 1)-1980) |
- |
500 |
|
(10% Discount for BIS) |
10(Resistance to Heat -Ball presure test) |
- |
600 |
|
(10% Discount for BIS) |
11(Resistance to burning as per clause 11 of IS: 9537 (Part 1)-1980) |
- |
750 |
|
(10% Discount for BIS) |
12(Electrical Characteristics-Test for electric strength as per clause 12.1.1 of IS: 9537 (Part 1)-1980) |
- |
750 |
|
(10% Discount for BIS) |
12(Electrical Characteristics-Insulation resistance test as per clause 12.1.2 of IS: 9537 (Part 1)-1980) |
- |
750 |
|
(10% Discount for BIS) |
6.1 - a(Marking) |
- |
200 |
|
10% Discount for BIS |
6.1 - b(Marking) |
- |
200 |
|
10% Discount for BIS |
6.1 - c(Marking) |
- |
200 |
|
10% Discount for BIS |
6.1 - d(Marking) |
- |
200 |
|
10% Discount for BIS |
6.2(Durability of Marking as per 6.4 of IS: 9537 (Part 1)-1980) |
- |
200 |
|
10% Discount for BIS |
6.3(Standard Mark on Conduit) |
- |
200 |
|
10% Discount for BIS |
7.1.1(Maximum and minimum outside diameter of socket) |
- |
200 |
|
10% Discount for BIS |
7.2(Minimum inside diameter of conduit) |
- |
200 |
|
10% Discount for BIS |
7.3(Length of conduit) |
- |
200 |
|
10% Discount for BIS |
7.4(Unifomity of The wall Thickness) |
- |
200 |
|
10% Discount for BIS |
7.1.1 Table-2(Length of Socket end) |
- |
200 |
|
10% Discount for BIS |
8.1(Construction as per clause 8 of IS: 9537 (Part 1)-1980) |
- |
200 |
|
10% Discount for BIS |
9.2(Bending Test At Low Temp (-5 ±2°C)) |
- |
500 |
|
10% Discount for BIS |
9.2(Bending Test At Room Temp) |
- |
500 |
|
10% Discount for BIS |
9.3(Compression Test at Full force applied (On load)) |
- |
500 |
|
10% Discount for BIS |
9.3(Compression Test (after removal of force) as per caluse 9.3.3 of IS: 9537 (Part 1)-1980) |
- |
500 |
|
10% Discount for BIS |
|
Complete
|
|
- |
- |
42 |
IS 9537 : Part 2 (1981) |
Specification for conduits for electrical installations: Part 2 rigid steel conduits |
Upto 50mm |
-
|
4500 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
7.2.1(Dimensions, (Minimum outside Diameter), IS 9537-2) |
- |
250 |
|
(10% Discount for BIS) |
7.2.2(Dimensions (Maximum outside Diameter), IS 9537-2) |
- |
250 |
|
(10% Discount for BIS) |
9.2(Mechanical Properties (Bending test), Cl. 9.3 of IS 9537-1) |
- |
1500 |
|
(10% Discount for BIS) |
9.3(Mechanical Properties (Compression Test), IS 9537-2) |
- |
1500 |
|
(10% Discount for BIS) |
13(External Influences, IS 9537-2) |
- |
200 |
|
(10% Discount for BIS) |
6.1(Marking, IS 9537-2) |
- |
200 |
|
10% Discount for BIS |
6.3(Marking, Cl. 6.4 of IS 9537-1) |
- |
200 |
|
10% Discount for BIS |
6.2(Marking, IS 9537-2) |
- |
200 |
|
10% Discount for BIS |
7.3.3(Uniformity of wall thickness, IS 9537-2) |
- |
200 |
|
10% Discount for BIS |
7.4(Screw threads, IS 9537-2) |
- |
1000 |
|
10% Discount for BIS |
8.1(Construction, Cl. 8 of IS 9537-1) |
- |
200 |
|
10% Discount for BIS |
8.2(Construction, IS 9537-2) |
- |
200 |
|
10% Discount for BIS |
|
Complete
|
|
- |
- |
43 |
IS 8042 (2015) |
White portland cement - Specification (Third Revision) |
All Grade |
-
|
7650 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
6 -Table 2- iv- a(Compressive Strength At 72 hrs ± 1 hr - IS 4031 Part 6) |
- |
300 |
|
(10% Discount for BIS) |
6 -Table 2- iv- b(Compressive Strength At 168 hrs ± 2 hr - IS 4031 Part 6) |
- |
300 |
|
(10% Discount for BIS) |
6 -Table 2- iv- c(Compressive Strength At 672 hrs ± 4 hr - IS 4031 Part 6) |
- |
300 |
|
(10% Discount for BIS) |
6 -Table 2- vi(Degree of whiteness-Annex B) |
- |
500 |
|
(10% Discount for BIS) |
6 -Table 2- i(Fineness 4031 Part 2) |
- |
- |
|
- |
6 -Table 2- ii- a(Expansion by Le Chatelier- 4031 Part 3) |
- |
- |
|
- |
6 -Table 2- ii- a(Expansion after aeration - 4031 Part 3) |
- |
- |
|
- |
6 -Table 2- ii- b(Expansion by Autoclave- 4031 Part 3) |
- |
- |
|
- |
6 -Table 2- iii- a(Setting Time Initial- 4031 Part 5) |
- |
- |
|
- |
6 -Table 2-iii- b(Setting Time Final- 4031 Part 5) |
- |
- |
|
- |
6 -Table 2- v(Transverse Strength - IS 4031 Part 8 (Optional)) |
- |
- |
|
- |
|
Complete
|
|
- |
- |
44 |
IS 7887 (1992) |
Mild steel wire rod for general engineering purposes - Specification (First Revision) |
All Grade |
-
|
2200 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
6.1(Carbon %) |
- |
200 |
|
(10% Discount for BIS) |
6.1(Manganese %) |
- |
200 |
|
(10% Discount for BIS) |
6.1(Silicon %) |
- |
200 |
|
(10% Discount for BIS) |
6.1(Sulphur %) |
- |
200 |
|
(10% Discount for BIS) |
6.1(Phosphorus %) |
- |
200 |
|
(10% Discount for BIS) |
|
Complete
|
|
- |
- |
45 |
IS 7098 : Part 1 (1988) |
Specification for crosslinked polyethylene insulated pvc sheathed cables: Part 1 for working voltages up to and including 1100 volts (First Revision) |
For Category 01 Only (Upto 630mm) |
-
|
23250 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
15.1 a) i)(Annealing Test ( For copper wire ) ) |
- |
600 |
|
(10% Discount for BIS) |
15.1 a) ii)(Tensile test (for aluminium) - Before stranding ) |
- |
300 |
|
(10% Discount for BIS) |
15.1 a) ii)(Tensile test (for aluminium) - After stranding ) |
- |
300 |
|
(10% Discount for BIS) |
3(CONDUCTOR: MATERIALS) |
- |
750 |
|
(10% Discount for BIS) |
15.1 d) ii) (Phyaical tests for insulation - Ageing in air Oven : Tensile Variation ) |
- |
400 |
|
(10% Discount for BIS) |
15.1 d) iii) (Phyaical tests for insulation : Hot set ) |
- |
400 |
|
(10% Discount for BIS) |
15.1 d) iv) (Phyaical tests for insulation : Shrinkage ) |
- |
400 |
|
(10% Discount for BIS) |
15.1 d) v) (Insulation: Waterabsorption(gravimetric)) |
- |
500 |
|
(10% Discount for BIS) |
15.1 e) i) (Physical tests for outer sheath : Tensile stregth) |
- |
300 |
|
(10% Discount for BIS) |
15.1 e) i) (Physical tests for outer sheath : Elongation) |
- |
300 |
|
(10% Discount for BIS) |
15.1 e) ii) (Physical tests for outer sheath- Ageing in air oven : Tensile stregth ) |
- |
600 |
|
(10% Discount for BIS) |
15.1 e) ii) (Physical tests for outer sheath -Ageing in air oven : Elongation ) |
- |
300 |
|
(10% Discount for BIS) |
15.1 e) ii) (Physical tests for outer sheath- Ageing in air oven : Tensile stregth Variation ) |
- |
600 |
|
(10% Discount for BIS) |
10.1(Core Identification) |
- |
300 |
|
(10% Discount for BIS) |
10.2(Core Identification- Neutral) |
- |
300 |
|
(10% Discount for BIS) |
10.4(Core Identification by number - Neutral ) |
- |
300 |
|
(10% Discount for BIS) |
15.1 a) iii)(Wrapping test (for aluminium)) |
- |
300 |
|
(10% Discount for BIS) |
15.1 a) iv)(Resistance test - Main conductor) |
- |
300 |
|
(10% Discount for BIS) |
15.1 a) iv)(Resistance test - Neutral conductor) |
- |
300 |
|
(10% Discount for BIS) |
15.1 d) i) (Phyaical tests for insulation : Tensile Test) |
- |
300 |
|
(10% Discount for BIS) |
15.1 d) i) (Phyaical tests for insulation : Elongation) |
- |
300 |
|
(10% Discount for BIS) |
15.1 d) ii) (Phyaical tests for insulation- Ageing in air oven : Elongation Variation ) |
- |
30 |
|
(10% Discount for BIS) |
15.1 d) iii) (Phyaical tests for insulation : Permanent set ) |
- |
300 |
|
(10% Discount for BIS) |
15.1 e) ii) (Physical tests for outer sheath -Ageing in air oven : Elongation Variation ) |
- |
300 |
|
(10% Discount for BIS) |
15.1 e) iii) (Sheath: Loss of mass in air oven) |
- |
300 |
|
(10% Discount for BIS) |
15.1 e) iv) (Phyaical tests for Sheath : Shrinkage ) |
- |
300 |
|
(10% Discount for BIS) |
15.1 e) v) (Sheath : Hot deformation) |
- |
300 |
|
(10% Discount for BIS) |
15.1 e) vi) (Sheath : Heat shock test) |
- |
200 |
|
(10% Discount for BIS) |
15.1 e) vii) (Sheath : Thermalstability) |
- |
150 |
|
(10% Discount for BIS) |
15.1 f)(INSULATION RESISTANCE TEST : Volume resistivity ) |
- |
200 |
|
(10% Discount for BIS) |
16.2(HIGH VOLTAGE TEST ) |
- |
300 |
|
(10% Discount for BIS) |
16.3(FLAMMABILITY TEST : Period of Burning ) |
- |
300 |
|
(10% Discount for BIS) |
16.3(FLAMMABILITY TEST : Unaffected length ) |
- |
200 |
|
(10% Discount for BIS) |
16.9(Oxygen Index Test) |
- |
200 |
|
(10% Discount for BIS) |
16.1(Flame Retardance Test on Single Cables) |
- |
200 |
|
(10% Discount for BIS) |
16.11(Flame Retardance Test on Bunched Cables) |
- |
200 |
|
(10% Discount for BIS) |
16.13(Test for Halogen Acid Gas Evolution) |
- |
200 |
|
(10% Discount for BIS) |
16.14(Temperature Index) |
- |
200 |
|
(10% Discount for BIS) |
17.1(Manufacturer'. identification) |
- |
200 |
|
(10% Discount for BIS) |
17.2(cable Indentification ) |
- |
200 |
|
(10% Discount for BIS) |
17.3(cable Code ) |
- |
200 |
|
(10% Discount for BIS) |
13.1.2(Armouring: Coverage ) |
- |
200 |
|
(10% Discount for BIS) |
13.1.3(Armouring: Direction of Lay ) |
- |
200 |
|
(10% Discount for BIS) |
13.2(Type of armour ) |
- |
200 |
|
(10% Discount for BIS) |
13.3(Armouring : Dimensions -Wire Diameter) |
- |
200 |
|
(10% Discount for BIS) |
13.3(Armouring : Dimensions -Formed wire ) |
- |
200 |
|
(10% Discount for BIS) |
13.4(Armour: Joint) |
- |
200 |
|
(10% Discount for BIS) |
13.5(Armouring : Resistance Test) |
- |
200 |
|
(10% Discount for BIS) |
13.6 a)(ARMOURING: Tensile Strength) |
- |
200 |
|
(10% Discount for BIS) |
13.6 b)(ARMOURING: Elongation ) |
- |
200 |
|
(10% Discount for BIS) |
13.6 c)(ARMOURING: Torsion Test (For round wire ) ) |
- |
200 |
|
(10% Discount for BIS) |
13.6 d)(ARMOURING: Winding Test(For formed wire)) |
- |
200 |
|
(10% Discount for BIS) |
13.6 e)(ARMOURING: Uniformity of zinc coating) |
- |
200 |
|
(10% Discount for BIS) |
13.6 f)(ARMOURING: Mass of zinc coating ) |
- |
200 |
|
(10% Discount for BIS) |
13.6 g)(ARMOURING: Resistivity) |
- |
200 |
|
(10% Discount for BIS) |
14.1(Outer Sheath : Application) |
- |
200 |
|
(10% Discount for BIS) |
14.2(Colour of outer sheath) |
- |
200 |
|
(10% Discount for BIS) |
14.3(Thickness of outer sheath - AVERAGE) |
- |
200 |
|
(10% Discount for BIS) |
14.3(Thickness of outer sheath - minimum) |
- |
200 |
|
(10% Discount for BIS) |
4(INSULATION : MATERIALS) |
- |
200 |
|
(10% Discount for BIS) |
5.1(FILLER AND INNER SHEATH) |
- |
200 |
|
(10% Discount for BIS) |
5.2(FILLER AND INNER SHEATH) |
- |
200 |
|
(10% Discount for BIS) |
7(OUTER SHEATH) |
- |
200 |
|
(10% Discount for BIS) |
8.1(CONDUCTOR: CONSTRUCTION) |
- |
200 |
|
(10% Discount for BIS) |
9.2(Thickness of Insulation - Average) |
- |
200 |
|
(10% Discount for BIS) |
9.3(Thickness of Insulation - Minimum) |
- |
200 |
|
(10% Discount for BIS) |
11(LAVING UP OF CORES) |
- |
200 |
|
(10% Discount for BIS) |
12.1 & 12.2(Inner sheath : Application) |
- |
200 |
|
(10% Discount for BIS) |
12.3(Thickness of Inner Sheath) |
- |
200 |
|
(10% Discount for BIS) |
|
Complete
|
|
- |
- |
46 |
IS 5509 (2000) |
Fire retardant plywood - Specification (Second Revision) |
All Grade |
-
|
9650 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
8(a) Length) |
- |
250 |
|
(10% Discount for BIS) |
8(b) Width) |
- |
250 |
|
(10% Discount for BIS) |
8.3 & Annex A (d) Edge Straightness 0.2% Max.) |
- |
300 |
|
(10% Discount for BIS) |
8.3 & Annex A (e) Edge Squareness 0.2% Max.) |
- |
300 |
|
(10% Discount for BIS) |
12.2(Moisture content ) |
- |
1000 |
|
(10% Discount for BIS) |
12.3.1(Flammability ) |
- |
1000 |
|
(10% Discount for BIS) |
12.3.2(Flame Penetration ) |
- |
750 |
|
(10% Discount for BIS) |
12.2.3(Rate of burning ) |
- |
750 |
|
(10% Discount for BIS) |
12.4(Glue adhesion (water resistance )) |
- |
300 |
|
(10% Discount for BIS) |
12.4(Modulus of Rupture, (Along the grain direction of the face veneer)) |
- |
750 |
|
(10% Discount for BIS) |
12.4(Modulus of Elasticity, (Along the grain direction of the face veneer)) |
- |
750 |
|
(10% Discount for BIS) |
12.4(Static Bending Strength as per BWR grade of IS 303 :) |
- |
250 |
|
(10% Discount for BIS) |
|
Complete
|
|
- |
- |
47 |
IS 4990 (2011) |
Plywood for concrete shuttering works - Specification (Third Revision) |
All Grade |
-
|
10600 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
7.2(DIMENSIONS &
TOLERANCES
) |
- |
500 |
|
(10% Discount for BIS) |
8.1(WORKMANSHIP AND FINISH ) |
- |
250 |
|
(10% Discount for BIS) |
10.1.1(MOISTURE CONTENT) |
- |
500 |
|
(10% Discount for BIS) |
10.1.2, 10.1.2.2(GLUE ADHESION IN DRY STATE) |
- |
750 |
|
(10% Discount for BIS) |
10.1.6(Chem)(TENSILE STRENGTH) |
- |
1000 |
|
(10% Discount for BIS) |
10.1.5(MYCOLOGICAL TEST ) |
- |
1000 |
|
(10% Discount for BIS) |
10.1.7 (Table-2)(STATIC BENDING STRENGTH) |
- |
150 |
|
(10% Discount for BIS) |
10.1.8 (Table-3)(WET BENDING STRENGTH) |
- |
200 |
|
(10% Discount for BIS) |
Cl. 10.1.8 (Table 3) (Cl. 10.1.8 (Table 3) (Modulus of Rupture: Across the Face Grain: Minimum Individual)) |
- |
250 |
|
(10% Discount for BIS) |
Cl. 10.1.8 (Table 3) (Cl. 10.1.8 (Table 3) (Modulus of Rupture: Across the Face Grain: Average)) |
- |
200 |
|
(10% Discount for BIS) |
Cl. 10.1.8 (Table 3) (Cl. 10.1.8 (Table 3) (Modulus of Rupture: Along the Face Grain: Minimum Individual)) |
- |
200 |
|
(10% Discount for BIS) |
Cl. 10.1.8 (Table 3) (Cl. 10.1.8 (Table 3) (Modulus of Rupture: Along the Face Grain: Average)) |
- |
250 |
|
(10% Discount for BIS) |
Cl. 10.1.8 (Table 3)(Cl. 10.1.8 (Table 3) (Modulus of Elasticity: Across the Face Grain: Minimum Individual)) |
- |
150 |
|
(10% Discount for BIS) |
Cl. 10.1.8 (Table 3) (Cl. 10.1.8 (Table 3) (Modulus of Elasticity: Across the Face Grain: Average)) |
- |
200 |
|
(10% Discount for BIS) |
Cl. 10.1.8 (Table 3) (Cl. 10.1.8 (Table 3) (Modulus of Elasticity: Along the Face Grain: Minimum Individual)) |
- |
250 |
|
(10% Discount for BIS) |
|
Complete
|
|
- |
- |
48 |
IS 4985 (2021) |
UNPLASTICIZED PVC PIPES FOR POTABLE WATER SUPPLIES SPECIFICATION Fourth Revision |
Upton315mm all Classes |
-
|
20000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
7(DIMENSIONS-PIPE-Nominal Diameter) |
- |
500 |
|
(10% Discount for BIS) |
7.2.1(DIMENSIONS-Socket) |
- |
400 |
|
(10% Discount for BIS) |
10.2(PHYSICAL AND CHEMICAL CHARACTERISTICS-Opacity) |
- |
200 |
|
(10% Discount for BIS) |
10.1(PHYSICAL AND CHEMICAL CHARACTERISTICS-Visual Appearance) |
- |
200 |
|
(10% Discount for BIS) |
10.4(PHYSICAL AND CHEMICAL CHARACTERISTICS- Reversion Test) |
- |
6000 |
|
(10% Discount for BIS) |
10.5(PHYSICAL AND CHEMICAL CHARACTERISTICS- Vicat Softening Temperature) |
- |
1500 |
|
(10% Discount for BIS) |
10.6(PHYSICAL AND CHEMICAL CHARACTERISTICS- Density) |
- |
500 |
|
(10% Discount for BIS) |
11.1-Table 6(MECHANICAL PROPERTIES-Hydrostatic Pressure Test (Acceptance Test)) |
- |
8000 |
|
(10% Discount for BIS) |
11.2(Resistance to External Blows at 0°C) |
- |
1500 |
|
(10% Discount for BIS) |
10.3(Effect on Water) |
- |
4000 |
|
(10% Discount for BIS) |
7(DIMENSIONS-PIPE-Nominal Diameter) |
- |
500 |
|
(10% Discount for BIS) |
7.2.1(DIMENSIONS-Socket) |
- |
400 |
|
(10% Discount for BIS) |
10.1.1(PHYSICAL AND CHEMICAL CHARACTERISTICS-Visual Appearance) |
- |
200 |
|
(10% Discount for BIS) |
10.4(PHYSICAL AND CHEMICAL CHARACTERISTICS- Reversion Test) |
- |
6000 |
|
(10% Discount for BIS) |
10.5(PHYSICAL AND CHEMICAL CHARACTERISTICS- Vicat Softening Temperature) |
- |
1500 |
|
(10% Discount for BIS) |
10.6(PHYSICAL AND CHEMICAL CHARACTERISTICS- Density) |
- |
500 |
|
(10% Discount for BIS) |
11.1-Table 6(MECHANICAL PROPERTIES-Hydrostatic Pressure Test (Acceptance Test)) |
- |
500 |
|
(10% Discount for BIS) |
11.2(Resistance to External Blows at 0°C) |
- |
1500 |
|
(10% Discount for BIS) |
10.3(Effect on Water Test) |
- |
500 |
|
(10% Discount for BIS) |
7.1.2.1(DIMENSIONS-PIPE-Thickness(Maximum)) |
- |
300 |
|
(10% Discount for BIS) |
7.1.2.1(DIMENSIONS-PIPE-Average Thickness) |
- |
300 |
|
(10% Discount for BIS) |
11.1-Table 6(MECHANICAL PROPERTIES-Hydrostatic Pressure Test (Type Test)) |
- |
2000 |
|
(10% Discount for BIS) |
10.7(Sulphated Ash Content) |
- |
1200 |
|
(10% Discount for BIS) |
10.1(Colour) |
- |
200 |
|
(10% Discount for BIS) |
6.1.2(PVC Resin) |
- |
7000 |
|
(10% Discount for BIS) |
7.1.1.1(DIMENSIONS-PIPE-Mean O.D. Variation) |
- |
500 |
|
(10% Discount for BIS) |
7.1.1.2(DIMENSIONS-PIPE-O.D. at any Point (Minimum)) |
- |
500 |
|
(10% Discount for BIS) |
7.1.1.2(DIMENSIONS-PIPE-O.D. at any Point (Maximum)) |
- |
500 |
|
(10% Discount for BIS) |
|
Complete
|
|
- |
- |
49 |
IS 4984 (2016) |
Polyethylene pipes for water supply - Specification (Fifth Revision) |
Upto 315mm all Classes |
-
|
44200 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
8.1.2 table -5(Internal Pressure Creep Rupture Test of Pipe Joints) |
- |
2000 |
|
(10% Discount for BIS) |
8.2(Longitudinal Reversion Test) |
- |
1000 |
|
(10% Discount for BIS) |
8.3(Carbon black) |
- |
1750 |
|
(10% Discount for BIS) |
8.4( Melt Flow Rate) |
- |
1000 |
|
(10% Discount for BIS) |
8.5 (Oxidation Induction Time) |
- |
1000 |
|
(10% Discount for BIS) |
8.6(Overall migration) |
- |
750 |
|
(10% Discount for BIS) |
8.7(Density) |
- |
2000 |
|
(10% Discount for BIS) |
8.8(Tensile Strength for Butt-fusion) |
- |
600 |
|
(10% Discount for BIS) |
8.9 table-6(Elongation at Break) |
- |
600 |
|
(10% Discount for BIS) |
8.10(Slow Crack Growth Rate) |
- |
9000 |
|
(10% Discount for BIS) |
8,/8.1/8.1.1 table-5(PERFORMANCE REQUIREMENTS / Hydraulic Characteristics/ Internal Pressure Creep Rupture Test of Pipe) |
- |
23000 |
|
(10% Discount for BIS) |
6.2(Colour) |
- |
500 |
|
(10% Discount for BIS) |
6.2.1(6.1.1 Identification Stripes) |
- |
1000 |
|
(10% Discount for BIS) |
5.3 (a)(Carbon Black Master Batch) |
- |
500 |
|
(10% Discount for BIS) |
5.3(b)(Carbon Black Master Batch) |
- |
500 |
|
(10% Discount for BIS) |
5.3(c)(Carbon Black Master Batch) |
- |
500 |
|
(10% Discount for BIS) |
5.3(d)(Carbon Black Master Batch) |
- |
500 |
|
(10% Discount for BIS) |
5.3(e)(Carbon Black Master Batch) |
- |
500 |
|
(10% Discount for BIS) |
5.2(Polyethylene Resin) |
- |
2000 |
|
(10% Discount for BIS) |
|
Complete
|
|
- |
- |
50 |
IS 4948 (2020.0) |
Welded steel wire fabric for general use - Specification (Second Revision) |
All Grade |
-
|
44200 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
Cl. 5.5(Tolerance of Size of Mesh) |
- |
1000 |
|
(10% Discount for BIS) |
|
Complete
|
|
- |
- |
51 |
IS 4923 (2017) |
Hollow steel sections for structural use - Specification (Third Revision) |
All Grade |
-
|
7000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
Cl.7.1(Sulphur- IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
500 |
|
(10% Discount for BIS) |
Cl.7.1(Phosphorus- IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
500 |
|
(10% Discount for BIS) |
Cl.7.1(Carbon Equivalent-IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
500 |
|
(10% Discount for BIS) |
Cl.9.1, Table 1(Dimensions and Properties of Hollow Sections (Weigth)) |
- |
500 |
|
(10% Discount for BIS) |
Cl. 10.2, Fig 1(Outside dimension (B)) |
- |
500 |
|
(10% Discount for BIS) |
Cl.9.1, Table 1(Dimensions and Properties of Hollow Sections(Thickness)) |
- |
500 |
|
(10% Discount for BIS) |
Cl. 10.4, Fig 2(Concavity, X1) |
- |
1000 |
|
(10% Discount for BIS) |
Cl. 10.5, Fig 3(Squareness of side) |
- |
200 |
|
(10% Discount for BIS) |
Cl. 10.6, Fig 4(External Corner Radius) |
- |
200 |
|
(10% Discount for BIS) |
Cl. 10.1, 14.1, 18.1(Straightness) |
- |
1500 |
|
(10% Discount for BIS) |
Cl. 14.1(Exact Length) |
- |
200 |
|
(10% Discount for BIS) |
Cl. 15.2, Table 3(Yield Strength- IS 1608) |
- |
500 |
|
(10% Discount for BIS) |
Cl. 15.2, Table 3(Tensile Strength- IS 1608) |
- |
1000 |
|
(10% Discount for BIS) |
Cl. 15.2, Table 3(Elongation- IS 1608) |
- |
500 |
|
(10% Discount for BIS) |
|
Complete
|
|
- |
- |
52 |
IS 4270 (2001) |
Steel tubes used for water wells specification (Third Revision) |
All Grade |
-
|
8650 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
5.2(sulphur) |
- |
200 |
|
(10% Discount for BIS) |
5.2(phosphorus) |
- |
200 |
|
(10% Discount for BIS) |
Cl 6(Tensile Test & Flattening Test) |
- |
500 |
|
(10% Discount for BIS) |
Cl 7(Outer Diameter, Thickness, Mass & Straightness) |
- |
2000 |
|
(10% Discount for BIS) |
Cl 9(Pipe ends, Angle of bevel & Root Face ) |
- |
500 |
|
(10% Discount for BIS) |
Cl 10(Outer Diameter & Overall Length) |
- |
1500 |
|
(10% Discount for BIS) |
|
Complete
|
|
- |
- |
53 |
IS 4246 (2002) |
Domestic gas stoves for use with liquefied petroleum gases - Specification (Fifth Revision) |
All Grade |
-
|
7600 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
Cl.24(Annexure E)(on no account the carbon monoxidel
carbon dioxide ratio of the exhaust gases of any burner.
operating at any consumption at which the burner is
stable at gas inlet pressure from 2452 kN/m2 to
3432 kN/m2 (25 gf/cm2 to 35 gf/cm2), exceed 0.02.) |
- |
500 |
|
(10% Discount for BIS) |
|
Complete
|
|
- |
- |
54 |
IS 3812 : Part 2 (2013) |
Pulverized Fuel Ash - Part 2 : For Use as Admixture in Cement Mortar and Concrete |
All Grade |
-
|
5250 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
7.1, Table 1(Fineness — Specific surface in m2 /kg) |
- |
500 |
|
(10% Discount for BIS) |
7.1, Table 1(Particles retained on 45 micron IS sieve (wet sieving)) |
- |
1000 |
|
(10% Discount for BIS) |
7.1, Table 1(Soundnes) |
- |
1500 |
|
(10% Discount for BIS) |
7.2(Uniformity Requirements) |
- |
- |
|
- |
|
Complete
|
|
- |
- |
55 |
IS 3812 (Part 1) (2013) |
Pulverized fuel ash - Specification: Part 1 For use as pozzolana in cement, cement mortar and concrete |
All Grade |
-
|
7750 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
7.1-Table 2(i)(PHYSICAL REQUIREMENTS-Fineness) |
- |
500 |
|
(10% Discount for BIS) |
7.1-Table 2(ii)(PHYSICAL REQUIREMENTS-Particles retained on 45 micron IS sieve) |
- |
750 |
|
(10% Discount for BIS) |
7.1-Table 2(iii)(PHYSICAL REQUIREMENTS-Average compressive strength) |
- |
1500 |
|
(10% Discount for BIS) |
7.1-Table 2(v)(PHYSICAL REQUIREMENTS-Soundness by autoclave test ) |
- |
1000 |
|
(10% Discount for BIS) |
7.2(Uniformity Requirements) |
- |
- |
|
- |
|
Complete
|
|
- |
- |
56 |
IS 3601 (2006) |
Steel tubes for mechanical and general engineering purposes - Specification (Second Revision) |
All Grade |
-
|
9000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
4.1(Sulphur-Percentage by mass) |
- |
200 |
|
(10% Discount for BIS) |
4.1(Phosphorus-Percentage by mass) |
- |
200 |
|
(10% Discount for BIS) |
13.1.3(Tensile Strength) |
- |
500 |
|
(10% Discount for BIS) |
13.1.1(Yield Stress) |
- |
500 |
|
(10% Discount for BIS) |
13.1.2(Elongation) |
- |
500 |
|
(10% Discount for BIS) |
13.2(Flattening Test) |
- |
1000 |
|
(10% Discount for BIS) |
13.5(Drift Expansion Test) |
- |
1000 |
|
(10% Discount for BIS) |
13.6(Crush Test) |
- |
1000 |
|
(10% Discount for BIS) |
|
Complete
|
|
- |
- |
57 |
IS 3589 (2001) |
Steel pipes for water and sewage (168.3 To 2540 Mm Outside Diameter) - Specification (Third Revision) |
All Grade |
-
|
7500 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
8.1 Table 2 Table 3(Carbon Content IS 228) |
- |
200 |
|
(10% Discount for BIS) |
8.1 Table 2 Table 3(Sulphur Content IS 228) |
- |
200 |
|
(10% Discount for BIS) |
8.1 Table 2 Table 3(Phosphorus Content IS 228) |
- |
200 |
|
(10% Discount for BIS) |
8.1 Table 2 Table 3(Manganese Content IS 228) |
- |
200 |
|
(10% Discount for BIS) |
9.1(Tensile test-Strength) |
- |
1000 |
|
(10% Discount for BIS) |
9.1(Tensile test- Elongation) |
- |
500 |
|
(10% Discount for BIS) |
9.2.1(Flattening test for
ERW pipes ) |
- |
750 |
|
(10% Discount for BIS) |
9.2.3(Flattening Test for
seamless pipes) |
- |
750 |
|
(10% Discount for BIS) |
10(Hydaulic pressure test) |
- |
1000 |
|
(10% Discount for BIS) |
11.1, Table 5.(Mass) |
- |
500 |
|
(10% Discount for BIS) |
11.1, Table 5.(Outside Diameter (OD)) |
- |
500 |
|
(10% Discount for BIS) |
11.1, Table 5.(Thickness) |
- |
500 |
|
(10% Discount for BIS) |
12.3.3(Ovality) |
- |
300 |
|
(10% Discount for BIS) |
12.5(Strightness) |
- |
200 |
|
(10% Discount for BIS) |
14.1(Visual inspection, Appearance and Workmanship) |
- |
200 |
|
(10% Discount for BIS) |
14.2(Visual inspection, Appearance and Workmanship) |
- |
200 |
|
(10% Discount for BIS) |
14.3(Visual inspection, Appearance and Workmanship) |
- |
200 |
|
(10% Discount for BIS) |
14.4(Visual inspection, Appearance and Workmanship-Dent Depth(Above 610 mm OD)) |
- |
200 |
|
(10% Discount for BIS) |
|
Complete
|
|
- |
- |
58 |
IS 3564 (1995) |
Hydraulically Regulated Door Closers -Specification |
All Grade |
-
|
7750 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
6(Nominal Sizes) |
- |
500 |
|
(10% Discount for BIS) |
8(Essential Requirements) |
- |
200 |
|
(10% Discount for BIS) |
B-1.2(a) Visual Inspection) |
- |
200 |
|
(10% Discount for BIS) |
B-1.4(c) Performance Requirements) |
- |
1500 |
|
(10% Discount for BIS) |
B-1.5(d) Endurance Test) |
- |
3500 |
|
(10% Discount for BIS) |
|
Complete
|
|
- |
- |
59 |
IS 3087 (2005) |
Practicle boards of wood and other lingnocellulosic materials (medium density) for general purposes -Specification |
All Grade |
-
|
8400 View breakup
Rs 8400/-(10% discount)
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
1 (i) Table 1(Density Variation (Flat Pressed Single Layer)) |
- |
500 |
|
(10% Discount for BIS) |
1 (ii) (a) Table 1(Water absorption, 2h soacking (Flat Pressed Single Layer)) |
- |
500 |
|
(10% Discount for BIS) |
1 (v) Table 1(Swelling in thickness due to surface absorption, (Flat Pressed Single Layer)) |
- |
500 |
|
(10% Discount for BIS) |
9.2, 11.4(Moisture content) |
- |
300 |
|
(10% Discount for BIS) |
|
Complete
|
|
- |
- |
60 |
IS 2831 (2012) |
Carbon steel cast billet ingots, billets, blooms and slabs for re-rolling into structural steel (Ordinary Quality) - Specification (Fourth Revision) |
All Grade |
-
|
4900 View breakup
Rs..4900/- (10% discount for BIS)
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
Cl. 6.1, Table 1(Carbon- IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
300 |
|
(10% Discount for BIS) |
Cl. 6.1, Table 1(Sulphur- IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
300 |
|
(10% Discount for BIS) |
Cl. 6.1, Table 1(Phosphorus- IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
300 |
|
(10% Discount for BIS) |
Cl. 6.1, Table 1(Manganese- IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
300 |
|
(10% Discount for BIS) |
Cl. 6.1, Table 1(Silicon- IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
300 |
|
(10% Discount for BIS) |
Cl. 6.1, Table 1(Copper- IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
300 |
|
(10% Discount for BIS) |
Cl. 6.1, Table 1(Vanadium- IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
300 |
|
(10% Discount for BIS) |
Cl. 6.1, Table 1(Aluminium- IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
300 |
|
(10% Discount for BIS) |
Cl. 6.1, Table 1(Titanium- IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
300 |
|
(10% Discount for BIS) |
Cl. 6.1, Table 1(Niobium- IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
300 |
|
(10% Discount for BIS) |
11 & 12(DIMENSIONS and Tolerances) |
- |
1000 |
|
(10% Discount for BIS) |
9( FREEDOM FROM DEFECTS) |
- |
1000 |
|
(10% Discount for BIS) |
|
Complete
|
|
- |
- |