BIS, Central Laboratory (CL)

20/9, Site 4, Sahibabad Industrial Area, Sahibabad, Ghaziabad, Ghaziabad, Uttar Pradesh, 201010
- sample@bis.gov.in
Scope List
Reset
994 Results
S.No. Indian Standard No. Product Grade / Type / Size / Designation etc. Testing Charges (Excl. Of Taxes) Validity Date Remark
811 IS 12681 (1989) Sodium nitrate for explosives and pyrotechnic industry - Specification - - View breakup
-
- -
-
812 IS 7098 : Part 1 (1988) Specification for crosslinked polyethylene insulated pvc sheathed cables: Part 1 for working voltages up to and including 1100 volts (First Revision) - 26250 View breakup
Rs.26250.00, extra charges @35% for each additional core shall be levied.optional test the charges shall be levied Rs.1200.00
- -
TF not available Cat C1 & C2
813 IS 12817 (2013) Stainless steel butt hinges - Specification (Second Revision) - Rs. 2400/- and testing charges as per referred Iss View breakup
-
- -
-
814 IS 3055 : Part 1 (1994) Clinical thermometers: Part 1 solid stem type - Specification (Second Revision) - Rs 5400.00 View breakup
-
- -
-
815 IS 3390 (1988) Specification for sphygmomanometers, mercurial (Second Revision) - Rs 7800.00 View breakup
-
- -
-
816 IS 14807 (2000) Phosphate solubilising bacterial inoculant (PSBI) - Specification - Rs.8740/- View breakup
-
- -
-
817 IS 16892 (2018) Sattu - Specification - - View breakup
-
- -
-
818 IS 798 (2020) Orthophosphoric Acid — Specification ( Third Revision ) - Rs.14822/- View breakup
-
- -
-
819 IS 797 (1982) Specification for common salt for chemical industries (Third Revision) - - View breakup
-
- -
500 gm x 3
820 IS 1239 : Part 1 (2004) Steel tubes, tubulars and other wrought steel fittings - Specification: Part 1 steel tubes (Sixth Revision) - Rs. 9200/- Excluding test on joints View breakup
Rs. 9200/- Excluding test on joints
- -
Sample size shall be minimum dia> 3mm and thickness > 0.8 mm; Excluding "-; i) Joint (Cl 10.1) , ii) Leak Proof Test (Cl 13)"
821 IS 1785 : Part 2 (1983) Specification for plain hard drawn steel wire for prestressed concrete: Part 2 as - Drawn wire (First Revision) - Rs 3000/- View breakup
-
- -
Sample size shall be minimum dia> 3mm and thickness > 0.8 mm; Excluding -; Relaxation (Cl 6.5), Proof Stress (Cl 6.2)
822 IS 11785 (1986) Specification for captan (Wettable Powder) WP - Rs 3650.00 View breakup
-
- -
-
823 IS 1785 : Part 1 (1983) Specification for plain hard - Drawn steel wire for prestressed concrete: Part 1 cold drawn stress - Relieved wire (Second Revision) - Rs. 27300.00 (Complete testing charges) Rs. 9300.00 (F View breakup
-
- -
Sample size shall be minimum dia> 3mm and thickness > 0.8 mm; Excluding -; Relaxation (Cl 6.5), Proof Stress (Cl 6.2)
824 IS 11010 (1984) Specification for ziram colloidal suspension - Rs.3500.00 View breakup
-
- -
-
825 IS 2879 (1998) Mild steel for metal arc welding electrodes - Specification (Third Revision) - Testing charges are Rs.9050/- View breakup
-
- -
Sample size shall be minimum dia> 3mm and thickness > 0.8 mm;
826 IS 4270 (2001) Steel tubes used for water wells specification (Third Revision) - Rs.7500/- View breakup
-
- -
Sample size shall be minimum dia> 3mm and thickness > 0.8 mm; Excluding -; Hydrostatic test (Cl 8)
827 IS 7887 (1992) Mild steel wire rod for general engineering purposes - Specification (First Revision) - Rs.7200/- View breakup
-
- -
Sample size shall be minimum dia> 3mm and thickness > 0.8 mm;
828 IS 6913 (1973) Specification for stainless steel tubes for the food and beverage industry - - View breakup
-
- -
Steel grade designation as per Table 2 may be declared. Sample 5x5 cm having size dia> 3mm and thickness> 0.8 mm.; Excluding Except corrosion test;
829 IS 10748 (2004) Hot - Rolled steel strip for welded tubes and pipes - Specification (Second Revision) - Please see remarks View breakup
i) For grade 1,2&3 = 3716 /-, Rounded off to Rs.3750/- ii) For grade 4,5 & 6 including Micro alloying elements = 6728/-, Rounded off to Rs.6750/- Remarks: Testing chargesfor each of the elements other than Table-1 (Silicon, Aluminum, Nitrogen etc.) will be Rs.1004/-
- -
Sample size shall be minimum dia> 3mm and thickness > 0.8 mm;
830 IS 6902 (1973) Specification for steel wire for spokes - - View breakup
-
- -
Sample size shall be minimum dia> 3mm and thickness > 0.8 mm;
831 IS 6649 (1985) Specification for hardened and tempered washers for high strength structural bolts and nuts (First Revision) - - View breakup
-
- -
Sample size shall be minimum dia> 3mm and thickness > 0.8 mm;
832 IS 6603 (2001) Stainless steel bars and flats - Specification (First Revision) - - View breakup
-
- -
Steel grade designation as per Table 3 may be declared. Sample 5x5 cm having size dia> 3mm and thickness> 0.8 mm.; Excluding Except corrosion test; Proof stress test (Cl 9.1), Charpy impact test (Cl 9.5)
833 IS 15227 (2002) Deltamethrin ULV - Specification - Rs.2150.00 View breakup
-
- -
-
834 IS 1161 (2014) Steel tubes for structural purposes - Specification (Fifth Revision) - 5725 View breakup
Rs. 5725/- and material testing charges as per relevant referred Iss
- -
Sample size shall be minimum dia> 3mm and thickness > 0.8 mm;
835 IS 6529 (1996) Stainless steel blooms, billets and slabs for forging - Specification (First Revision) - - View breakup
-
- -
Steel Grade/designation as per Table 1 may be declared. Sample size shall be minimum dia> 3mm and thickness > 0.8 mm; Excluding Except corrosion test; Corrosion resistance test (Cl 13)
836 IS 6911 (2017) Stainless steel plate, sheet and strip - Specification (Second Revision) - - View breakup
-
- -
Steel Grade/designation as per Table 1 may be declared. Sample size shall be minimum dia> 3mm and thickness > 0.8 mm; Excluding Except corrosion test; Test facility is also not available for 0.2 % proof stress
837 IS 432 : Part 2 (1982) Mild Steel and Medium Tensile Steel Bars and Hard-Drawn Steel Wire for Concrete Reinforcement: Part 2 Hard-Drawn Steel Wire - Rs 3900/- View breakup
-
- -
Sample size shall be minimum dia> 3mm and thickness > 0.8 mm; Excluding -; Proof stress test (Cl 8.2)
838 IS 15228 (2002) Cyfluthrin - Emulsion in water (EW) - Specification - Rs.3500.00 View breakup
-
- -
Excluding Cl. 3.3.1 Cyfluthrin Content;
839 IS 6392 (2020) Steel Pipes Flanges — Specification ( First Revision ) - Rs 3070/- + View breakup
-
- -
Sample grade/designation as per relevant IS of Table 1 to be declared. Sample size shall be minimum dia> 3mm and thickness > 0.8 mm;
840 IS 5651 (1987) Specification for steels for pneumatic tools (First Revision) - - View breakup
-
- -
Sample size shall be minimum dia> 3mm and thickness > 0.8 mm;

Designed, Developed and Maintained by:

Arohatech IT Services (P) Ltd.

Contact for any query/support: supportlims@bis.gov.in