| 931 |
IS 778 (1984) |
Specification for 2010 copper alloy gate, globe and check valves for waterworks purposes (Fourth Revision) |
- |
Rs 4500/- View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 6- Table 1-i) (Brass(Body)-Cl 7 and table 1 of IS 1264) |
- |
|
|
|
| 6- Table 1-i) (Leaded tin Bronze(Body)-Cl 3 and table 1 of IS 318) |
- |
|
|
|
| 6- Table 1-ii) (Forged Brass(Bonnet or cover)-Cl 8 , table 3 and FLB of IS 6912) |
- |
|
|
|
| 6- Table 1-iv) (High-tensile brass( stem) - Cl 4.1 and table 1 of IS 320) |
- |
|
|
|
| 4 (Classification ) |
- |
|
|
|
| 7.1.4.1- Table 3 (Diameter of flange - IS 778) |
- |
|
|
|
| 7.1.4.1- Table 3 (Thickness of flange - IS 778) |
- |
|
|
|
| 7.1.4.1- Table 3 (Diameter of Belt circle -IS 778) |
- |
|
|
|
| 7.1.4.1- Table 3 (No. of holes - IS 778) |
- |
|
|
|
| 7.1.4.1- Table 3 (Diameter of holes -IS 778) |
- |
|
|
|
| 7.2.2 (Bonnet Flanges - IS 778) |
- |
|
|
|
| 7.1.3.1 (Screwed Body End -IS 778) |
- |
|
|
|
|
- |
- complete |
| 932 |
IS 1580 (1991) |
Bituminous compounds for waterproofing and caulking purposes - Specification (Second Revision) |
- |
Rs. 2172/ View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Clause 4.2.2 and 5 (water content) |
- |
|
|
|
| Clause 4.2.2 and 5 (ash content) |
- |
|
|
|
| Clause 4.2.2 and 5 (water content) |
- |
|
|
|
| 4.2 (Composition) |
- |
|
|
|
| Clause 4.2.2 , Table 1,(iii) (Flow Test) |
- |
|
|
|
| Clause 4.2.2 , Table 1,(iv) (Flash point ,degree celsius, Min) |
- |
|
|
|
| Clause 4.2.2 , Table 1,(v) (Flexibility and adhesion) |
- |
|
|
|
| Clause 4.2.2 , Table 1,(vi) a (Consistency a) Before setting ( test after 1 h ) Min) |
- |
|
|
|
| Clause 4.2.2 , Table 1,(vi) b (Consistency b) After setting ( test after 24 h ) Min) |
- |
|
|
|
| Clause 4.2.1 (Composition) |
- |
|
|
|
| Clause 4.2.2 , Table 1,(i) (Water content, percent by mass, Max) |
- |
|
|
|
| Clause 4.2.2 , Table 1,(ii) (Ash content, percent by mass, Max) |
- |
|
|
|
| Clause 4.2.2 , Table 1,(iv) (Flash point ,degree celsius, Min) |
- |
|
|
|
| Clause 4.2.2 , Table 1,(iii) (Flow Test) |
- |
|
|
|
| Clause 4.2.2 , Table 1,(v) (Flexibility and adhesion) |
- |
|
|
|
| Clause 4.2.2 , Table 1,(vi) a (Consistency a) Before setting ( test after 1 h ) Min) |
- |
|
|
|
| Clause 4.2.2 , Table 1,(vi) b (Consistency b) After setting ( test after 24 h ) Min) |
- |
|
|
|
| 4.3 (Keeping Quality) |
- |
|
|
|
| Clause 4.2.2 , Table 1,(ii) (Ash content, percent by mass, Max) |
- |
|
|
|
| Clause 4.2.2 , Table 1,(i) (Water content, percent by mass, Max) |
- |
|
|
|
| Clause 4.2.1 (Composition) |
- |
|
|
|
| Clause 4.2.2 , Table 1,(iii) (Flow Test) |
- |
|
|
|
| Clause 4.2.2 , Table 1,(iv) (Flash point ,degree celsius, Min) |
- |
|
|
|
| Clause 4.2.2 , Table 1,(v) (Flexibility and adhesion) |
- |
|
|
|
| Clause 4.2.2 , Table 1,(vi) a (Consistency a) Before setting ( test after 1 h ) Min) |
- |
|
|
|
| Clause 4.2.2 , Table 1,(vi) b (Consistency b) After setting ( test after 24 h ) Min) |
- |
|
|
|
| Clause 4.2.1 (Composition) |
- |
|
|
|
| Clause 4.2.2 , Table 1,(iii) (Flow Test) |
- |
|
|
|
| Clause 4.2.2 , Table 1,(iv) (Flash point ,degree celsius, Min) |
- |
|
|
|
| Clause 4.2.2 , Table 1,(v) (Flexibility and adhesion) |
- |
|
|
|
| Clause 4.2.2 , Table 1,(vi) a (Consistency a) Before setting ( test after 1 h ) Min) |
- |
|
|
|
| Clause 4.2.2 , Table 1,(vi) b (Consistency b) After setting ( test after 24 h ) Min) |
- |
|
|
|
|
- |
- - |
| 933 |
IS 738 (1994) |
Wrought aluminium alloys, drawn tube for general engineering purposes - Specification (Third Revision) |
- |
- View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl. 8.1, Table 1 (Aluminium- IS 504 : 1963
or 1S 11085 : 1984 or any other established
instrumental/chemical method. ) |
- |
|
|
|
| Cl. 8.1, Table 1 (Copper- IS 504 : 1963
or 1S 11085 : 1984 or any other established
instrumental/chemical method. ) |
- |
|
|
|
| Cl. 8.1, Table 1 (Silicon- IS 504 : 1963
or 1S 11085 : 1984 or any other established
instrumental/chemical method. ) |
- |
|
|
|
| Cl. 8.1, Table 1 (Zinc- IS 504 : 1963
or 1S 11085 : 1984 or any other established
instrumental/chemical method. ) |
- |
|
|
|
| Cl. 8.1, Table 1 (Iron- IS 504 : 1963
or 1S 11085 : 1984 or any other established
instrumental/chemical method. ) |
- |
|
|
|
|
- |
- Grade as per Table 1 IS 738 may please declared. Sample size shall be minimum dia> 3mm and thickness > 0.8 mm; |
| 934 |
IS 164 (2015) |
Ready mixed paint for road marking - Specification (Second Revision) |
- |
- View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl 5.5, Table 1, S.no. x) (Flash point ) |
- |
|
|
|
| 5.1 (Composition) |
- |
|
|
|
| 5.2 (Application) |
- |
|
|
|
| Cl 5.3 (Durability) |
- |
|
|
|
| Cl. 5.4 (Lead Restriction) |
- |
|
|
|
| Cl 5.5, Table 1, S.no. i) (Drying time, a) Surface dry) |
- |
|
|
|
| Cl 5.5, Table 1, S.no. i) (Drying time, b) Hard dry) |
- |
|
|
|
| Cl 5.5, Table 1, S.no. ii) (Consistency) |
- |
|
|
|
| Cl 5.5, Table 1, S.no. iii) (Finish) |
- |
|
|
|
| Cl 5.5, Table 1, S.no. iv) (Colour) |
- |
|
|
|
| Cl 5.5, Table 1, S.no. v) (Wet opacity) |
- |
|
|
|
| Cl 5.5, Table 1, S.no. vi) (Resistance to bleeding) |
- |
|
|
|
| Cl 5.5, Table 1, S.no. vii) (Recoating property) |
- |
|
|
|
| Cl 5.5, Table 1, S.no. viii) (Resistance to wear: a) For Grade 1) |
- |
|
|
|
| Cl 5.5, Table 1, S.no. viii) (Resistance to wear: a) For Grade 2) |
- |
|
|
|
| Cl 5.5, Table 1, S.no. ix) (Residue on sieve) |
- |
|
|
|
| Cl 5.5, Table 1, S.no. xi) (xi) Mass) |
- |
|
|
|
| Cl 5.6 & Cl 5.6.2.1 (Optional Requirement for ECO-Mark, volatile organic compounds,) |
- |
|
|
|
| 5.6.2.2 (Optional Requirement for ECO-Marktoxic metals such as cadmium, chromium (VI) and their compounds) |
- |
|
|
|
|
- |
- IS is withdrawn. Revisied 2023 version is now available.; |
| 935 |
IS 13334 : Part 2 (2014) |
Skimmed milk powder - Specification: Part 2 extra grade (First Revision) |
- |
Rs 10430/- View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Table 1 (ix) (Bacterial count (IS 5402)) |
- |
|
|
|
| Table 1 (x) (Coliform count (IS 5401 - Part 1)) |
- |
|
|
|
| Table 1 (xi) (Escherichia coli (IS 5887 - Part 1)) |
- |
|
|
|
| Table 1 (xii) (Coagulase positive Staphylococcus aureus (IS 5887 - Part 2)) |
- |
|
|
|
| Table 1 (xiii) (Salmonella (IS 5887 - Part 3)) |
- |
|
|
|
| Table 1 (xiv)(a) (Spore Count: a)Aerobic (Bacillus cereus) Type m (IS 5887 - Part 6)) |
- |
|
|
|
| Table 1 (xiv)(b) (Spore Count: b) Anaerobic (Sulfite reducing Clostridia) Type m (ISO 15213 : 2003)) |
- |
|
|
|
| Table 1 (xiv)(b) (Spore Count: b) Anaerobic (Sulfite reducing Clostridia) Type M (ISO 15213 : 2003)) |
- |
|
|
|
| Table 1 (xiv)(b) (Spore Count: b) Anaerobic (Sulfite reducing Clostridia) Type m (ISO 15213 : 2003)) |
- |
|
|
|
| Table 1 (xv) (Listeria monocytogenes (IS 14988 - Part 2 : 2001)) |
- |
|
|
|
| Table 1 (i) (Moisture (IS 116231or 16072)) |
- |
|
|
|
| Table 1 (ii) (Milk protein in milk solids not fat (IS 72192)) |
- |
|
|
|
| Table 1 (iii) (Milk fat (IS 117213) or Annex B) |
- |
|
|
|
| Table 1 (viii) (Scorched particles (equivalent to Disc B) (IS 13500)) |
- |
|
|
|
| Table 1 (vii) (Lactate content (IS 11202)) |
- |
|
|
|
| Table 1 (v) (Total ash (on dry basis), Annex B of IS 14433) |
- |
|
|
|
| Table 1 (iv) (Insolubility index (IS 12759)) |
- |
|
|
|
| Table 1 (vii) (Lactate content (IS 11202)) |
- |
|
|
|
| Table 1 (xv) (Listeria monocytogenes (IS 14988 - Part 2 : 2001)) |
- |
|
|
|
|
- |
- 500 gm x 3 |
| 936 |
IS 4246 (2002) |
Domestic gas stoves for use with liquefied petroleum gases - Specification (Fifth Revision) |
- |
Please see remarks View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl.24(Annexure E) (on no account the carbon monoxidel
carbon dioxide ratio of the exhaust gases of any burner.
operating at any consumption at which the burner is
stable at gas inlet pressure from 2452 kN/m2 to
3432 kN/m2 (25 gf/cm2 to 35 gf/cm2), exceed 0.02.) |
- |
|
|
|
| Cl.23 (There shall be no extinction of the flames on any
of the burners operating at maximum consumption
when the appliance is placed in a general (not
localized) current of air with a velocity of 2 m/s, as
measured with a rotating vane anemometer. The
location of the appliance relative to neighboring walls
and the direction of the draught shall be varied to
correspond to likely conditions of appliance installation.
This applies for all pressures from 2452 kN/m2 to
3432 kN/m2 (25 gf/cm2 to 35 gf/cm2).) |
- |
|
|
|
| 24 (Annex - E) (Combustion (CO and CO2 ratio)) |
- |
|
|
|
| 4.1 (Requirement) |
- |
|
|
|
| 5 (Materials) |
- |
|
|
|
| 6 (Design for Maintenance) |
- |
|
|
|
| 7 (Rigidity and Stability) |
- |
|
|
|
| 8 (Workmanship and Finish) |
- |
|
|
|
| 9 (Gas Taps) |
- |
|
|
|
| 10 (Injector Jets) |
- |
|
|
|
| 11 (Burners) |
- |
|
|
|
| 13.1 (Gas Soundness) |
- |
|
|
|
| 13.2 (Gas Leak Detector) |
- |
|
|
|
| 14 (Gas Inlet Connections) |
- |
|
|
|
| 15 (Strength and Rigidity) |
- |
|
|
|
| 16 (General Conditions of Test) |
- |
|
|
|
| 17.1.1 (Gas Consumption) |
- |
|
|
|
| 18 (Ignition and Flame Travel) |
- |
|
|
|
| 19 (Flame Stability) |
- |
|
|
|
| 20 (Noise Control) |
- |
|
|
|
| 21 (Flash Back) |
- |
|
|
|
| 22 (Formation of Soot) |
- |
|
|
|
| 23 (Resistance to Draught) |
- |
|
|
|
| 24 (Combustion) |
- |
|
|
|
| 25 (Fire Hazard and Limiting Temperature) |
- |
|
|
|
| 26 (Thermal Efficiency) |
- |
|
|
|
| 27.1 (Type Tests) |
- |
|
|
|
| 27.2 (Routine Tests) |
- |
|
|
|
| 29 (Marking) |
- |
|
|
|
| 30 (Packing) |
- |
|
|
|
| 5.1.2 (Toughened glass- Adhesive tape) |
- |
|
|
|
| 5.1.3 (Thermal Shock test) |
- |
|
|
|
|
- |
- - |
| 937 |
IS 733 (1983) |
Specification for wrought aluminium and aluminium alloy bars, rods and sections (For General Engineering Purposes) (Third Revision) |
- |
please see remarks View breakup
TESTING charges per man-hour are Rs. 75.00. Testing charge for
physical tests are Rs. 450.00, and for Chemical tests will depend upon the elements to be tested according to the designation of the
material
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Table-1, Clause - 5.1 (Copper) |
- |
|
|
|
| Table-1, Clause - 5.1 (Iron) |
- |
|
|
|
| Table-1, Clause - 5.1 (Magnesium) |
- |
|
|
|
| Table-1, Clause - 5.1 (Manganese) |
- |
|
|
|
| Table-1, Clause - 5.1 (Titanium) |
- |
|
|
|
| Table-1, Clause - 5.1 (Silicon) |
- |
|
|
|
| Table-1, Clause - 5.1 (Chromium) |
- |
|
|
|
| Table-1, Clause - 5.1 (Zinc) |
- |
|
|
|
| Cl. 4 (Freedom from Defects) |
- |
|
|
|
| 7 (Dimension - IS 3965) |
- |
|
|
|
| Cl. 5.1, Table 2 (Tensile Strength- IS 1816) |
- |
|
|
|
| Cl. 5.1, Table 2 (Elongation on 50 mm or 5.65√So Gauge Length) |
- |
|
|
|
|
- |
- - |
| 938 |
IS 158 (2015) |
Ready mixed paint, brushing, bituminous, black, acid, alkali and heat resisting - Specification (Fourth Revision) |
- |
- View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl 4.3, Table 1, S.no.xv) (Flash point ,) |
- |
|
|
|
| 4.1 (Composition) |
- |
|
|
|
| 4.2.1 (Lead Restriction) |
- |
|
|
|
| Cl 4.3, Table 1, S.no. i) (Drying time, Hard dry) |
- |
|
|
|
| Cl 4.3, Table 1, S.no. ii) (Consistency) |
- |
|
|
|
| Cl 4.3, Table 1, S.no. iii) (Finish) |
- |
|
|
|
| Cl 4.3, Table 1, S.no. iv) (Wet opacity) |
- |
|
|
|
| Cl 4.3, Table 1, S.no. v) (Colour) |
- |
|
|
|
| Cl 4.3, Table 1, S.no. vi) ( Mass) |
- |
|
|
|
| Cl 4.3, Table 1, S.no.xvi) (Keeping properties) |
- |
|
|
|
| Cl 4.3, Table 1, S.no.viii) (Flexibility and adhesion) |
- |
|
|
|
| Cl 4.3, Table 1, S.no. ix) (Stripping test ) |
- |
|
|
|
| Cl 4.3, Table 1, S.no. x) (Protection against corrosion under conditions of condensation) |
- |
|
|
|
| Cl 4.3, Table 1, S.no.xi) (Volatile matter, perce) |
- |
|
|
|
| Cl 4.3, Table 1, S.no.xii) (Resistance to acid) |
- |
|
|
|
| Cl 4.3, Table 1, S.no.xiii) (Resistance to alkali) |
- |
|
|
|
| Cl 4.3, Table 1, S.no.xiv) (Resistance to Heat) |
- |
|
|
|
|
- |
- For colour, finish, wet opacity, resistance to acid, alkali and heat approved sample is required. Test facility is not available for mentioned exclusion parameter.;
Excluding Water content; |
| 939 |
IS 14735 (1999) |
Unplasticized Polyvinyl Chloride (UPVC) Injection Moulded Fittings for Soil and Waste Discharge System for Inside and Outside Buildings Including Ventilation and Rain Water System - |
- |
Total Testing Charges : Rs. 9970.00 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 5 (Colour of fittings) |
- |
|
|
|
| 7.1,Table 1 (Wall thickness) |
- |
|
|
|
| 7.2 ,Table 2&3 (Socket Dimensions) |
- |
|
|
|
| 10 (Workmanship) |
- |
|
|
|
| 11.1 (Solvent cement type or Rubber ring type) |
- |
|
|
|
| 11.2 (Socket and spigot configeration) |
- |
|
|
|
| 12.1 (Visual appearance) |
- |
|
|
|
| 12.2 (Stress relief test) |
- |
|
|
|
| 12.3 (Vicat softening tempewrature) |
- |
|
|
|
| Cl.13, IS 12235 (P-7)-2004, (Resistance to Sulphuric Acid) |
- |
|
|
|
| 16.1 (Impact test) |
- |
|
|
|
|
- |
- Complete for mechanical requirements;
Excluding Titanium dioxide content, effect on water; |
| 940 |
IS 14151 : Part 1 (1999) |
Irrigation equipment - Sprinkler pipes - Specification: Part 1 polyethylene pipes (First Revision) |
- |
Rs.17350/- View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 7.3 (Tensile Test) |
- |
|
|
|
| 7.2 (Reversion Test) |
- |
|
|
|
| 6.1 (VISUAL APPEARANCE) |
- |
|
|
|
| 5.1 table -1 (DIMENSIONS OF PIPES) |
- |
|
|
|
| 4.1.1 (density shall be between 940.4 kg/m’ and 958.4 kg/m3 (both inclusive) when determined at 27°C according to procedure prescribed in Annex A of IS 7328. The value of the density shall also not differ from the nominal value by more than 3 kg/m2 as per 5.2.1.1 of IS 7328.) |
- |
|
|
|
| Cl. 4.2 , IS 2530-1963, Cl. 10 (Cabon Black Content) |
- |
|
|
|
| 4.3 (Anti-oxidant) |
- |
|
|
|
|
- |
- - |
| 941 |
IS 281 (2009) |
Mild steel sliding door bolts for use with padlocks - Specification (Fourth Revision) |
- |
- View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4 (SIZES) |
- |
|
|
|
| 6 (DIMENSIONS AND TOLERANCES-A) |
- |
|
|
|
| 6-Table 1 (DIMENSIONS AND TOLERANCES-A) |
- |
|
|
|
| 6-Table 1 (DIMENSIONS AND TOLERANCES-B) |
- |
|
|
|
| 6-Table 1 (DIMENSIONS AND TOLERANCES-C) |
- |
|
|
|
| 6-Table 1 (DIMENSIONS AND TOLERANCES-D) |
- |
|
|
|
| 6-Table 1 (DIMENSIONS AND TOLERANCES-E) |
- |
|
|
|
| 6-Table 1 (DIMENSIONS AND TOLERANCES-F) |
- |
|
|
|
| 6-Table 1 (DIMENSIONS AND TOLERANCES-G) |
- |
|
|
|
| 6-Table 1 (DIMENSIONS AND TOLERANCES-H) |
- |
|
|
|
| 6-Table 1 (DIMENSIONS AND TOLERANCES-J) |
- |
|
|
|
| 6-Table 1 (DIMENSIONS AND TOLERANCES-T) |
- |
|
|
|
| 6-Table 1 (DIMENSIONS AND TOLERANCES-DIMENSIONS AND TOLERANCES-No. of Screw on Staple or Clip to accommodate Wood Screw N0 (IS 451)) |
- |
|
|
|
| 6-Table 1 (DIMENSIONS AND TOLERANCES-No. of Rivets on bolts plates) |
- |
|
|
|
| 6-Table 1 (DIMENSIONS AND TOLERANCES-No. of Rivets on Socket) |
- |
|
|
|
| 6-Table 1 (DIMENSIONS AND TOLERANCES-No. of Screw holes on bolt) |
- |
|
|
|
| 6-Table 1 (DIMENSIONS AND TOLERANCES-No. of Screw holes on Socket) |
- |
|
|
|
| 6-Table 1 (DIMENSIONS AND TOLERANCES-No. of Screw holes on Staple) |
- |
|
|
|
| 6-Table 1 (DIMENSIONS AND TOLERANCES-no. of 8m Sqire Holes for carriage bolts for plate and sockets) |
- |
|
|
|
| 6-Table 1 (DIMENSIONS AND TOLERANCES-no. of 8m Sqire Holes for carriage bolts for Staple) |
- |
|
|
|
| 7.1 (MANUFACTURE-General) |
- |
|
|
|
| 7.2 (MANUFACTURE-Sliding Door Bolts, Plate Type) |
- |
|
|
|
| 7.3 (MANUFACTURE-Sliding Bolts, Clip or Bolt Type) |
- |
|
|
|
|
- |
- Sample size shall be minimum dia> 3mm and thickness > 0.8 mm; |
| 942 |
IS 278 (2009) |
Galvanized steel barbed wire for fencing - Specification (Fourth Revision) |
- |
- View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 5 Table-1 (Sizes Diameter of Line wire) |
- |
|
|
|
| 5 Table-1 (Sizes Diamater of Point wire) |
- |
|
|
|
| 5 Table-1 (Sizes Mass of Completed barbed wire) |
- |
|
|
|
| 5 Table-1 (Sizes Distance between two barbs) |
- |
|
|
|
| 5 Table-1 (Sizes No. of Lays between the two consequtive barbs) |
- |
|
|
|
| 7.1 (Manufacture) |
- |
|
|
|
| 7.2 (Manufacture) |
- |
|
|
|
| 9.1 (Freedom from defects) |
- |
|
|
|
| 12.1 (Tensile Strength) |
- |
|
|
|
| 12.1 (Breaking load) |
- |
|
|
|
| 12.2.1 (Mass of zinc coating (line wire)) |
- |
|
|
|
| 12.2.2 (Mass of zinc coating (point wire)) |
- |
|
|
|
| 12.2 (Uniformity of zinc coating) |
- |
|
|
|
| 12.3 (Ductility) |
- |
|
|
|
| Cl. 6 . Table 1 of IS 7887 (Grade : 1,2,3,4,4M,6,6M,7,7M,8,8M,9,10,10M) (Carbon- IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
|
|
|
| Cl. 6 . Table 1 of IS 7887 (Grade : 1,2,3,4,4M,6,6M,7,7M,8,8M,9,10,10M) (Sulphur- IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
|
|
|
| Cl. 6 . Table 1 of IS 7887 (Grade : 1,2,3,4,4M,6,6M,7,7M,8,8M,9,10,10M) (Phosphorus- IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
|
|
|
| Cl. 6 . Table 1 of IS 7887 (Grade : 1,2,3,4,4M,6,6M,7,7M,8,8M,9,10,10M) (Manganese- IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
|
|
|
| Cl. 6 . Table 1 of IS 7887 (Grade : 1,2,3,4,4M,6,6M,7,7M,8,8M,9,10,10M) (Silicon- IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
|
|
|
|
- |
- Grade of the material and type of killing as per IS 7887 may please be declared.; |
| 943 |
IS 10124 : Part 2 (2009) |
Fabricated pvc - U fittings for potable water supplies - Specification: Part 2 specific requirements for sockets (Second Revision) |
- |
Rs.1800/ View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 3.2.1, Table-1, Fig-1 (Minimum wall thickness for working pressure) |
- |
|
|
|
| Clause 3.2.2, and Fig. 2. (Minimum wall thickness for working pressure) |
- |
|
|
|
| 3.2.2, and Fig. 2 (Dimensions of Socket for Elastomeric Sealing Ring Joint) |
- |
|
|
|
|
- |
- Excluding Test facility not available for Cl 6.2 Short Term Hydraulic Test, Cl 5.1.3 Out of Roundness; |
| 944 |
IS 10124 : Part 1 (2009) |
Fabricated PVC-U Fittings for Potable Water Supplies - Specification Part 1 General Requirements (Second Revision) |
- |
Rs 1500/- View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 5.1 Table-1 Fig.1 (Dimension of Socket length) |
- |
|
|
|
| 5.2 Table-2 Fig.2 (Dimensions of socket for elastomeric sealing ring) |
- |
|
|
|
|
- |
- Excluding Test facility not available for Cl 6.2 Short Term Hydraulic Test, Cl 5.1.3 Out of Roundness; |
| 945 |
IS 276 (2000) |
Austenitic - Manganese steel castings - Specification (First Revision) |
- |
please see remarks View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 8.1,8.3, Table 1 (C) |
- |
|
|
|
| 8.1,8.3, Table 1 (Si) |
- |
|
|
|
| 8.1,8.3, Table 1 (Mn) |
- |
|
|
|
| 8.1,8.3, Table 1 (p) |
- |
|
|
|
| 8.1,8.3, Table 1 (S) |
- |
|
|
|
| 8.1,8.3, Table 1 (Cr) |
- |
|
|
|
| 8.1,8.3, Table 1 (Mo) |
- |
|
|
|
| 8.1,8.3, Table 1 (Ni) |
- |
|
|
|
| 9.1 (WORKMANSHIP AND FINISH) |
- |
|
|
|
| 10.1 (FREEDOM FROM DEFECTS) |
- |
|
|
|
| 14.2 (Brinell Hardness Test) |
- |
|
|
|
| 14.3 (Bend Test) |
- |
|
|
|
| 14.4, IS 1608 Pt 1 (Tensile test) |
- |
|
|
|
|
- |
- - |
| 946 |
IS 210 (2009) |
Grey iron castings - Specification (First Revision) |
- |
Rs.2700.00 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 6 (Chemical Composition(chemical
composition shall be as agreed to between the
purchaser and the manufacturer.)) |
- |
|
|
|
| 7.1 (WORKMANSHIP AND FINISH) |
- |
|
|
|
| 10.1 (FREEDOM FROM DEFECTS) |
- |
|
|
|
| 10.2 (FREEDOM FROM DEFECTS) |
- |
|
|
|
| 13 (SIZE OF TEST BARS-Diameter) |
- |
|
|
|
| 13 (SIZE OF TEST BARS-Length) |
- |
|
|
|
| 15, Table 3 (TENSIL.E TEST- IS 1608 Part1 ) |
- |
|
|
|
| 16, Table 3 (Hardness Test) |
- |
|
|
|
| 17,Annex B (TRANSVERSE TEST) |
- |
|
|
|
|
- |
- Since the composition of cast iron shall be left to the discretion ofthe manufacturer , as such element to be tested with specified requirement and tolerances if any may please be declared with method of testing. Sample Size 5 pcs of 5x5 cm having dia> 3mm and thickness > 0.8 mm.;
Excluding -; Microstracture,Frequency of test,Tensile test(preparing of sample Above 28),Transverse test,Hydrostatic test |
| 947 |
IS 208 (1996) |
Door Handles - Specification ( Sixth Revision ) |
- |
- View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4.2 -Table 1- i (Ref. Cl 7.1 -Table 3 Grade 0 of IS 1079 : 2017) (Chemical composition - Carbon - IS 228) |
- |
|
|
|
| 4.2 -Table 1- iii (Ref. Cl 3.1, Table 1 Grade LCB-2 of IS 292 : 1983) (Chemical composition - Copper plus incidental nickel - IS 3685:1966) |
- |
|
|
|
| 4.2 -Table 1- iv (Ref. Cl 5.1, Table 1 Grade 5230 or 4600 of IS 617 : 1994) (Chemical composition - Copper - IS 504:1963, IS 7658:1975, IS 11035:1984) |
- |
|
|
|
| 4.2 -Table 1- v (Ref. Cl 6, Table 1 Grade 19000 of IS 737 : 2008) (Chemical composition - Aluminium - IS 504:1963) |
- |
|
|
|
| 4.2 -Table 1- vi (Ref. Cl 5.1, Table 1 Grade 63400 or 65032 of IS 733 : 1983) (Chemical composition - Aluminium - IS 504:1963) |
- |
|
|
|
| 4.2 -Table 1- vii (Ref. Cl 6.1 of IS 210 : 2009) (Chemical composition - Sulphur and/or Phosphorous) |
- |
|
|
|
| 4.2 -Table 1- viii (Ref. Cl 4.1, Table 1 of IS 742 : 1981) (Chemical composition - Aluminium- IS 2600:1964) |
- |
|
|
|
| 4.2 -Table 1- viii (Ref. Cl 4.1, Table 1 of IS 742 : 1981) (Chemical composition - Impurities-Nickel- IS 2600:1964) |
- |
|
|
|
| 3 (TYPES-Doors handle shall be of the following types according to the materials used:) |
- |
|
|
|
| 5.1 (MANUFACTURE- General) |
- |
|
|
|
| 6.1 Table2A & 2B and Fig 1,2,3,4 (DIMENSIONS - Size (A,B,C,D,E,F,G,H,I)) |
- |
|
|
|
| 6.1 Table2A & 2B and Fig 1,2,3,4 (DIMENSIONS - Size 1. No. in each Lug 2. No. in a plate when a continious plate is used 3. Size Designation of Counter-sunk Head Wood Screws
(as per IS 6760: 1972)) |
- |
|
|
|
|
- |
- Test facility is available for material test only as per Table 1. Sample dia > 3mm or thickness > 0.8 mm can only be tested, Sample size 5 pcs 5x5 cm;
Excluding All except Coating Test; |
| 948 |
IS 1166 (1986) |
Specification for condensed milk, partly skimmed and skimmed condensed milk (Second Revision) |
- |
10430 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl.5.1.10.1 (Salmonella IS 5887 Part 3) |
- |
|
|
|
| Cl.5.1.10.1 (Shigella IS 5887 Part 7) |
- |
|
|
|
| Cl.5.1.10.2 (Coliform Count IS 5401 Part 1) |
- |
|
|
|
| Cl.5.1.10.3 (Yeast and Mould Count IS 5403) |
- |
|
|
|
| Cl.5.1.10.4 (Coagulase positive Staphylococcus aureus IS 5887 Part 2) |
- |
|
|
|
| Cl.5.1.10.5 (Escherichia coli IS 5887 Part 1) |
- |
|
|
|
| Table 1 (i) (Apendix B) (Total milk solids -Condensed Milk) |
- |
|
|
|
| Table 1 (ii) (IS : 11762-
1986) (Fat -Condensed Milk) |
- |
|
|
|
| Table 1 (iii) (Apendix C) (Sucrose -Condensed Milk) |
- |
|
|
|
| Table 1 (vi) (Apendix D) (Titratable acidity (as lactic acid) -Condensed Milk) |
- |
|
|
|
|
- |
- 500 gm x 3 |
| 949 |
IS 205 (1992) |
Non - Ferrous metal butt specification (Fourth Revision) |
- |
1500 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 5.1- Table 2,3,4,5 & Fig-1 & 2 (Dimensions- Type of Hinge 1.Length 2.Breadth 3.Butt Dia 4.Pin Dia 5.Thickness of Flap) |
- |
|
|
|
| 5.1- Table 2,3,4,5 & Fig-1 & 2 (Dimensions- 1. Holes for Screw Desination 2. No. of screw Holes) |
- |
|
|
|
| 6.1 (Manufacture- General) |
- |
|
|
|
| 6.2- Table 2,3,4,5 (Kunckles) |
- |
|
|
|
| 6.3 (Screw Holes) |
- |
|
|
|
| 6.3.1- Table 2,3,4,5 & Fig-1 & 2 (Screw Holes) |
- |
|
|
|
| 6.3.2- Table 2,3,4,5 (Number of Holes) |
- |
|
|
|
| 6.3.3 Fig-1 (Position of Holes) |
- |
|
|
|
| 4.1 -Table 1-Flap- i (Ref. Cl 5.1, Table 1 Designation 64430 or 65032 of IS 733 : 1983) (Chemical composition - Aluminium - IS 504) |
- |
|
|
|
| 4 -Table 1- Flap-ii (Ref. Cl 8.1, Table 1 of IS 319 : 1989) (Chemical composition - Copper - IS 3685:1966) |
- |
|
|
|
| 4 -Table 1- Flap-iii (Ref. Cl 3.1, Table 1 Grade LCB-2 of IS 292 : 1983) (Chemical composition - Copper plus incidental nickel - IS 3685:1966) |
- |
|
|
|
| 4 -Table 1- Flap-iv (Ref. Cl 6.1 , Table 1 Designation CuZn40 of IS 410 : 1977) (Chemical composition - Copper - IS 3635:1966) |
- |
|
|
|
| 4.1 -Table 1-Pin- i (Ref. Cl 5.1, Table 1 Designation 64430 of IS 733 : 1983) (Chemical composition - Aluminium - IS 504) |
- |
|
|
|
| 4.1 -Table 1-Pin- ii (Ref. Cl 6.1, Table 1 of IS 7608 : 1987) (Chemical composition - Tin - IS 4027:1967) |
- |
|
|
|
| 4.1 -Table 1-Pin- iii (Ref. Cl 6 of IS 280:1978- Cross ref. Cl. 6.1 -Table 1 of IS 7887 : 1992) (Chemical composition - Carbon - IS 228) |
- |
|
|
|
| 4.1 -Table 1-Pin- iv (Ref. Cl 4.1 -Table 1 of IS 4413 : 1981) (Chemical composition - Copper - IS 3685:1966) |
- |
|
|
|
| 4.1 -Table 1-Pin- v (Ref. Cl 7.1 -Table 1 of IS 6528 : 1995) (Chemical composition - Carbon - IS 228) |
- |
|
|
|
|
- |
- Grade/Designation of material of componenets as per Table 1 may please be declared. Sample dia > 3mm or thickness > 0.8 mm can only be tested; |
| 950 |
IS 13592 (2013) |
Unplasticized Polyvinyl Chloride (PVC-U) Pipes for Soil and Waste Discharge System Inside and Outside Buiildings Including Ventilation and Rainwater System |
- |
9000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl.5 (Surface colour of the pipes shall be dark shade of grey) |
- |
|
|
|
| Cl.7.1 (Mean out side Diameter (For less than or equal to 40 mm- Average of 8 , For higher diameters up to 110 mm average of 6)) |
- |
|
|
|
| Cl.7.1 (Outside Diameter at any point (Take 8 reading reported minimum, maximum)) |
- |
|
|
|
| Cl.7.1 (Wall thickness "minimum,maximum" (Take 8 reading)) |
- |
|
|
|
| Cl.7.3.2 (Dimensions of sockets for solvent cementing and
grooved sockets of pipes shall be as given in Tables 3
and 4 respectively, read with Fig. 2 and 3.) |
- |
|
|
|
| Cl.8.1 (The internal and external surface of the pipes shall be
smooth and clean, and free from grooving and other
defects. The end shall be clearly cut and shall be square
with the axis of the pipe. The end may be chamfered
on the plain side.) |
- |
|
|
|
| Cl.8.2 (When tested by the method described in IS 12235
(Part 5), a length of pipe sample of 200 ± 20 mm shall
not alter in length by more than 5 percent. In the case
of socket ended pipes, this test shall be carried out on
the plain portion of pipe taken at least 100 mm away
from the root of the socket.) |
- |
|
|
|
| Cl8.3 (This test shall be carried out for socket end pipes only.
When tested by the method described in IS 12235
(Part 6), the test specimens shall not show blisters,
excessive delamination or cracking or signs of weld
line splitting.) |
- |
|
|
|
| Cl.8.4 (When determined in accordance with IS 12235 (Part 2),
the vicat softening temperature of the specimen shall
not be less than 79°C.) |
- |
|
|
|
| Cl. 9, IS 12235 Part 7 (Resistance to Sulphuric Acid) |
- |
|
|
|
| Cl.10.1 (When tested by method prescribed in IS 12235 (Part 9),the pipe shall have a true impact rate of not more than
10 percent. Mass of striker and height of fall shall be
as per Annex A.) |
- |
|
|
|
| Cl.10.2 (When determined in accordance with the method
described in IS 12235 (Part 13), the tensile strength at
break shall not be less than 45 MPa.) |
- |
|
|
|
|
- |
- Excluding Effect on water and Cl 10.1 |
| 951 |
IS 8931 (1993) |
copper alloy fancy single taps, combination tap assembly and stop valves for water services |
- |
Rs 3600/ View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl 3 (TERMINOLOGY) |
- |
|
|
|
| Cl 4 (NOMINAL SIZES) |
- |
|
|
|
| Cl 6.6 (Screw Threads) |
- |
|
|
|
| Cl 6.7 (Waterway) |
- |
|
|
|
| Cl 6.9 (Body Seat) |
- |
|
|
|
| Cl 6.10 (Bonnet assembly) |
- |
|
|
|
| Cl 6.11 (Gland Packaging) |
- |
|
|
|
| Cl 6.12 (Flanges) |
- |
|
|
|
| Cl 6.13 (Knob) |
- |
|
|
|
| Cl 7.1 (Thickness) |
- |
|
|
|
| Cl 7.2 (Body) |
- |
|
|
|
| Cl 7.3 (Bonnet Assembly) |
- |
|
|
|
| Cl 7.3.3 (Washer Plate) |
- |
|
|
|
| Cl 9.2.1 (Water Tightness Characteristic) |
- |
|
|
|
| Cl 9.2.2 (Pressure Resistance Characteristic) |
- |
|
|
|
| Cl 9.2.3 (Hydraulic characteristic (Flow rate)) |
- |
|
|
|
| Cl 9.2.4 (Mechanical strength characteristic) |
- |
|
|
|
| Cl 7.2 (Body) |
- |
|
|
|
| Cl 7.3 (Bonnet Assembly) |
- |
|
|
|
| Cl 7.3.3 (Washer Plate) |
- |
|
|
|
| Cl 9.2.1 (Water Tightness Characteristic) |
- |
|
|
|
| Cl 9.2.2 (Pressure Resistance Characteristic) |
- |
|
|
|
| Cl 9.2.3 (Hydraulic characteristic (Flow rate)) |
- |
|
|
|
| Cl 9.2.4 (Mechanical strength characteristic) |
- |
|
|
|
| Clause 5.1, Table -1 (Cast Brass LCB-2 of IS 292 1983,Ingots, Cu + Ni) |
- |
|
|
|
| Clause 5.1, Table -1 (Cast Brass Grade DCB - 2 of IS 1264 : 1981, Die Casting, Cu) |
- |
|
|
|
| Clause 5.1, Table -1 (Leaded In Tin Bronze ,LTB-2 of IS 318, Sn) |
- |
|
|
|
| Clause 5.1, Table -1 (Brass, Tyape 1 half Hard of IS 319 : 2007, Grade -1 , Cu) |
- |
|
|
|
| Clause 5.1, Table -1 (Grade FIB of IS 6912 : 2005, Cu) |
- |
|
|
|
| Clause 5.1, Table -1 (Brass Rods Grade- CuZn 37 of IS 410 : 1977, Cu) |
- |
|
|
|
| Clause 5.1, Table -1 (Stainless Steel Grade- X04Cr17Ni12Mo2 of IS 4454(Pt-4) : 1975, C) |
- |
|
|
|
| Clause 5.1, Table -1 (Zinc base Alloys Grade- Zn Al 4 of IS 742 : 1981, Al) |
- |
|
|
|
| Clause 5.1, Table -1 (Cast Brass LCB-2 of IS 292 1983,Ingots, Cu + Ni) |
- |
|
|
|
|
- |
- Grade/Designation of material of componenets as per Table 1 may please be declared. Sample dia > 3mm or thickness > 0.8 mm can only be tested; |
| 952 |
IS 13428 (2005) |
Packaged natural mineral water specification (Second Revision) |
- |
19200 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 6.1.1 (Escherichia coli(or thermotolerant bacteria)) |
- |
|
|
|
| 6.1.2 (Coliform , bacteria) |
- |
|
|
|
| 6.1.3 (Faecal Streptococci ) |
- |
|
|
|
| 6.1.3 (Staphylococcus Aureus) |
- |
|
|
|
| 6.1.4 (Sulphite Reducing Anaerobes ) |
- |
|
|
|
| 6.1.5 (Pseudomonas Aeruginosa ) |
- |
|
|
|
| 6.1.6 (Yeast and Mould ) |
- |
|
|
|
| 6.1.7 (Salmonella ) |
- |
|
|
|
| 6.1.7 (Shigella) |
- |
|
|
|
| 6.1.8 (Vibrio cholera ) |
- |
|
|
|
| 6.1.8 (Vibrio parahemolyticus) |
- |
|
|
|
| 6.2 Table-1 i (Colour) |
- |
|
|
|
| 6.2 Table-1 ii (Odour) |
- |
|
|
|
| 6.2 Table-1 iii (Taste) |
- |
|
|
|
| 6.2 Table-1 iv (Turbidity) |
- |
|
|
|
| 6.2 Table-1 v (Total dissolved solids) |
- |
|
|
|
| 6.2 Table-2 i (Nitrate (as NO3)) |
- |
|
|
|
| 6.2 Table-2 ii (Nitrite (as NO2)) |
- |
|
|
|
| 6.2 Table-2 iii (Sulphide (as H2S)) |
- |
|
|
|
|
- |
- 13 Litre for chemical and 12 lt for microbiology |
| 953 |
IS 204 : Part 2 (1992) |
Tower bolts - Specification: Part 2 non - Ferrous metals (Fifth Revision) |
- |
Rs.2100.00. View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4 -Table 3- i (Ref. Cl 8, Table 1 Designation 63400 of IS 1285 : 2002) (Chemical composition - Aluminium - IS 504) |
- |
|
|
|
| 4 -Table 3- ii (Ref. Cl 5.1, Table 1 Designation 65032 of IS 733 : 1983) (Chemical composition - Aluminium - IS 504) |
- |
|
|
|
| 4 -Table 3- iii (Ref. Cl 6.1 , Table 1 Designation CuZn40 of IS 410 : 1977) (Chemical composition - Copper - IS 3635:1966) |
- |
|
|
|
| 4 -Table 3- iv (Ref. Cl 3.1, Table 1 Grade CB-2 of IS 292 : 1983) (Chemical composition - Nickel - IS 3685:1966) |
- |
|
|
|
| 4 -Table 3- v (Ref. Cl 8.1, Table 1 Grade II of IS 319 : 1974) (Chemical composition - Copper - IS 3685:1966) |
- |
|
|
|
| 4 -Table 3- vi (Ref. Cl 4.1, Table 1 Alloy ZnAl4 of IS 742 : 1981) (Chemical composition - Aluminium- IS 2600:1964) |
- |
|
|
|
| 4 -Table 3- vi (Ref. Cl 4.1, Table 1 Alloy ZnAl4 of IS 742 : 1981) (Chemical composition - Zinc- IS 2600:1964) |
- |
|
|
|
| 5.2.1 Table 1 (Particulars-Barrel Tower Bolts) |
- |
|
|
|
| 5.2.2 Table 2 (Particulars-Skeleton Tower Bolts) |
- |
|
|
|
| 6.1- Table 1 (Dimension of Barrel tower bolts-1.Size 2.Length of Bolt or Barrel-(A or B) 4.Width of Barrel-C 5.Dia of Bolt-D 6.Length of Socket-E 7.Thickness of Metal of Barrel (Brass or Zink Alloy/Aluminium alloy/Sheet Brass)-F 8.Dia of bore of barrel or socket- G ) |
- |
|
|
|
| 6.1- Table 1 (Dimension of barrel tower bolts-Minimum No. of equally Spaced holes in Barrel & Socket for wooden screw no 6) |
- |
|
|
|
| 6.2- Table 2 (Dimension of Skeleton Tower Bolts 1.Size 2.Length of Bolt -A 3.Length of Bolt Plate -B 4.Width of Bolt Plate or Staple-C 5.Dia of Bolt-D 6.Length of Staple-E 7.Thickness of Plate or Socket (Brass /Aluminium alloy or Zink Alloy)-F 8.Dia of bore of Plate or Staple-G 9.Dia of shank of Knob ) |
- |
|
|
|
| 6.2- Table 2 (Dimension of Skeleton Tower Bolts- Nos of Staples) |
- |
|
|
|
| 6.2- Table 2 (Dimension of Skeleton Tower Bolts-Minimum No. of Screw holes for wood screw no 4) |
- |
|
|
|
|
- |
- Grade/Designation, Quality type of killing and declaration regarding micro alloying elements addition may please be declared as per relevant IS of Table 3 of IS 204(P-2). Sample size- 5 pcs of 5 cm x 5 cm having dia> 3mm and thickness >0.8 mm; |
| 954 |
IS 204 : Part 1 (1991) |
Tower bolts - Specification: Part 1 ferrous metals (Fifth Revision) |
- |
Rs.2100.00. View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4 -Table 5- i (Ref. Cl 7, Table 3, HR1 grade of IS 1079 : 2017) (Chemical composition - Carbon - IS 228) |
- |
|
|
|
| 4 -Table 5- i (Ref. Cl 7, Table 3, HR1 grade of IS 1079 : 2017) (Chemical composition - Manganese - IS 228) |
- |
|
|
|
| 4 -Table 5- i (Ref. Cl 7, Table 3, HR1 grade of IS 1079 : 2017) (Chemical composition - Phosphorus - IS 228) |
- |
|
|
|
| 4 -Table 5- i (Ref. Cl 7, Table 3, HR1 grade of IS 1079 : 2017) (Chemical composition - Sulphur - IS 228) |
- |
|
|
|
| 4 -Table 5- ii (Ref. Cl 5, Table 1, E300-C grade of IS 2062 : 2011) (Chemical composition - Carbon - IS 228) |
- |
|
|
|
| 4 -Table 5- ii (Ref. Cl 5, Table 1, E300-C grade of IS 2062 : 2011) (Chemical composition - Manganese - IS 228) |
- |
|
|
|
| 4 -Table 5- ii (Ref. Cl 5, Table 1, E300-C grade of IS 2062 : 2011) (Chemical composition - Phosphorus - IS 228) |
- |
|
|
|
| 4 -Table 5- ii (Ref. Cl 5, Table 1, E300-C grade of IS 2062 : 2011) (Chemical composition - Silicon - IS 228) |
- |
|
|
|
| 4 -Table 5- ii (Ref. Cl 5, Table 1, E300-C grade of IS 2062 : 2011) (Chemical composition - Carbon Equivalen(CE) - IS 228) |
- |
|
|
|
| 4 -Table 5- iii (Ref. Cl 6.1 of IS 210 : 2009) (Chemical composition - Sulphur and/or Phosphorous) |
- |
|
|
|
| 5.2.1 Table 1 (Particulars-Barrel Tower Bolts) |
- |
|
|
|
| 5.2.2 Table 2 (Particulars-Sami Barrel Tower Bolts) |
- |
|
|
|
| 5.2.3 Table 3 (Particulars-Riveted or Spot Welded Tower Bolts) |
- |
|
|
|
| 5.2.4 Table 4 (Particulars-Skeleton Tower Bolts) |
- |
|
|
|
| 6.1- Table 1 (Dimension of Barrel tower bolts-1.Size 2.Length of Bolt-A 3.Length of Barrel-B 4.Width of Barrel-C 5.Dia of Bolt-D 6.Length of Socket-E 7.Thickness of mild steel sheet for barrel-F 8.Dia of bore of barrel or socket- G ) |
- |
|
|
|
| 6.1- Table 1 (Dimension of Barrel tower bolts-Minimum No. of equally Spaced Screw holes in Barrel and Socket for wood screw no 6) |
- |
|
|
|
| 6.2- Table 2 (Dimension of Sami Barrel Tower Bolts 1.Size 2.Length of Bolt-A 3.Length of Bolt Plate-B 4.Width of Bolt Plate-C 5.Dia of Bolt-D 6.Length of Socket-E 7.Thickness of Bolt Plate or Socket-F 8.Dia of bore of Bolt Plate or socket G ) |
- |
|
|
|
| 6.2- Table 2 (Dimension of Sami Barrel Tower Bolts-Minimum No. of equally Spaced Screw holes in Bolt Plate and Socket for wood screw no 6) |
- |
|
|
|
| 6.3- Table 3 (Dimension of Riveted or Spot Welded Tower Bolts- 1.Size 2.Length of Bolt-A 3.Length of Bolt Plate-B 4.Width of Bolt Plate-C 5.Dia of Bolt-D 6.Length of Socket-E 7. Length of Strap-E" 8.Thickness of Back Plate -F 9.Thickness of Socket or Upper Plate and Strap- F" 10.Dia of bore of Bolt Plate or socket- G 11. Length of Alternative Socket-H ) |
- |
|
|
|
| 6.3- Table 3 (Dimension of Riveted or Spot Welded Tower Bolts-Minimum No. of equally Spaced Screw holes in Bolt Plate and Socket for wood screw no 6) |
- |
|
|
|
| 6.4- Table 4 (Dimension of Skeleton Tower Bolts 1.Size 2.Length of Bolt-A 3.Length of Bolt Plate-B 4.Width of Bolt Plate-C 5.Dia of Bolt-D 6.Length of Staple-E 7.Thickness of Plate or Staple -F 8.Dia of bore of Plate or Staple-G 9.Dia of shank of Knob-J) |
- |
|
|
|
| 6.4- Table 4 (Dimension of Skeleton Tower Bolts- Nos of Staples) |
- |
|
|
|
| 9 (PACKING) |
- |
|
|
|
|
- |
- Grade/Designation, Quality type of killing and declaration regarding micro alloying elements addition may please be declared as per relevant IS of Table 5 of IS 204(P-1). Sample size- 5 pcs of 5 cm x 5 cm having dia> 3mm and thickness >0.8 mm; |
| 955 |
IS 1079 (2017) |
Hot rolled carbon steel sheet, plate and strip - Specification (Seventh Revision) |
- |
- View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl 8 (UTM) |
- |
|
|
|
| Cl 9 (Press) |
- |
|
|
|
| Cl 10 (Die Press) |
- |
|
|
|
| Cl 12 (Workmanship) |
- |
|
|
|
| Cl 13 (Length, Width & Thickness) |
- |
|
|
|
| 6.1 (Carbon %) |
- |
|
|
|
| 6.1 (Manganese %) |
- |
|
|
|
| 6.1 (Phosphorus %) |
- |
|
|
|
| 6.1 (Sulphur %) |
- |
|
|
|
| 6.1 ( Copper %) |
- |
|
|
|
| 6.1 ( Aluminium %) |
- |
|
|
|
| 6.1 ( Nitrogen%) |
- |
|
|
|
| 6.1 ( Nb) |
- |
|
|
|
| 6.1 (V) |
- |
|
|
|
| 6.1 ( Ti) |
- |
|
|
|
| 6.1 (Cr) |
- |
|
|
|
| 6.1 (Mo) |
- |
|
|
|
| 6.1 (Ni) |
- |
|
|
|
| 6.1 (Silicon %) |
- |
|
|
|
|
- |
- Grade/Designation, Quality type of killing and declaration regarding micro alloying elements addition may please be declared. Sample size- 5 pcs of 5 cm x 5 cm having dia> 3mm and thickness >0.8 mm; |
| 956 |
IS 3854 (1997) |
Switches for domestic and similar purposes - Specification (Second Revision) |
- |
Please see remarks. View breakup
6A Screw type terminals-Rs.4900/-, 6A Screwless type terminals-Rs.5850/-,10A Screw type terminals-Rs.5050/-, 10A Screwless type terminals-Rs.6400/-, 16A Screw type terminals-Rs.5850/-,16A Screwless type terminals-Rs.7900/-, 20A-Rs.5250/-, 25A-Rs.5900/-, 32A-Rs.6250/-, 40A-Rs.6550/-, 63A-Rs.6200/-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 6 (Rating) |
- |
|
|
|
| 7 (Classification) |
- |
|
|
|
| 7 (Classification) |
- |
|
|
|
| 7 (Classification) |
- |
|
|
|
| 7 (Classification) |
- |
|
|
|
| 7 (Classification) |
- |
|
|
|
| 7 (Classification) |
- |
|
|
|
| 7 (Classification) |
- |
|
|
|
| 8 (Marking) |
- |
|
|
|
| 8 (Marking) |
- |
|
|
|
| 8 (Marking) |
- |
|
|
|
| 8 (Marking) |
- |
|
|
|
| 8 (Marking) |
- |
|
|
|
| 8 (Marking) |
- |
|
|
|
| 8 (Marking) |
- |
|
|
|
| 8.9 (Marking) |
- |
|
|
|
| 6 (Rating) |
- |
|
|
|
| 10 (Protection against Electric Shock) |
- |
|
|
|
| 11.1 (Provision for earthing) |
- |
|
|
|
| 12 (Terminals) |
- |
|
|
|
| 12.2.1 (Terminals) |
- |
|
|
|
| 12.2.2 (Connection of conductor) |
- |
|
|
|
| 12.2.3 (Mechanical strength of terminals) |
- |
|
|
|
| 12.2.4 (Resistance to corrosion) |
- |
|
|
|
| 12.2.5 (Undue damage to conductor) |
- |
|
|
|
| 12.2.7 (Insertion of conductor) |
- |
|
|
|
| 12.2.9 (Locking against accidental loosening) |
- |
|
|
|
| 12.2.11 (Distance between screw and conductor) |
- |
|
|
|
| 12.3.2 (Screwless terminals) |
- |
|
|
|
| 12.3.3 (Connectin of conductor) |
- |
|
|
|
| 12.3.4 (Material of terminals) |
- |
|
|
|
| 12.3.5 (Clamping) |
- |
|
|
|
| 12.3.7 (v) Interconnection of conductors [Cl. 12.3.7]) |
- |
|
|
|
| 12.3.11 (vi) Electrical & Thermal Stresses [Cl 12.3.11]) |
- |
|
|
|
| 12.3.12 (vii) Deflection Stresses [Cl. 12.3.12]) |
- |
|
|
|
| 13.1 (a) Insulating lining, barriers and the like [Cl 13.1]) |
- |
|
|
|
| 13.2 (b) Construction of switch [Cl 13.2]) |
- |
|
|
|
| 13.2 (i) Installation Test) |
- |
|
|
|
| 13.3 (c) Covers,cover plates and actuating members [Cl 13.3]) |
- |
|
|
|
| 13.4 (d) Ordinary switches [Cl 13.4]) |
- |
|
|
|
| 13.5 (e) Rotary switches [Cl 13.5]) |
- |
|
|
|
| 13.6 (f) Screws and other means [Cl 13.6]) |
- |
|
|
|
| 13.7 (g) Combination of switches or switches and socket outlets [Cl 13.7]) |
- |
|
|
|
| 13.8 (h) Assessories combined with switches [Cl. 13.8]) |
- |
|
|
|
| 13.9 (j) Switches other than ordinary switches [Cl. 13.9]) |
- |
|
|
|
| 13.1 (k) Switches to be installed in a box [Cl. 13.10]) |
- |
|
|
|
| 13.11 (l) Surface type switches other than ordinary switch [Cl. 13.11]) |
- |
|
|
|
| 13.12, 13.13, 13.14 (m) Inlet opening [Cl. 13.12.13.13 & 13.14]) |
- |
|
|
|
| 13.15 (q) Requirements for membrane in inlet opening [ Cl. 13.15]) |
- |
|
|
|
| 13.15 (q) Requirements for membrane in inlet opening [ Cl. 13.15]) |
- |
|
|
|
| 13.15 (q) Requirements for membrane in inlet opening [ Cl. 13.15]) |
- |
|
|
|
| 13.15 (q) Requirements for membrane in inlet opening [ Cl. 13.15]) |
- |
|
|
|
| 14 (Mechanism [Cl. 14]) |
- |
|
|
|
| 15.1 (Resistance to Ageing, to Harmful Ingress of water and to Humidity [Cl. 15]: Resistance to Ageing, [Cl. 15.1]) |
- |
|
|
|
| 15.2 (b)Resistance to Harmful ingress of water [Cl. 15.2]) |
- |
|
|
|
| 15.3 (c) Resistance to Humidity [Cl. 15.3]) |
- |
|
|
|
| 16.1 (Insulation resistance [Cl. 16.1]) |
- |
|
|
|
| 16.2 ( Electric Strength [Cl. 16.2]) |
- |
|
|
|
| 17 (Temperature- rise [Cl. 17]) |
- |
|
|
|
| 18 (Marking and breaking Capacity[Cl. 18]) |
- |
|
|
|
| 19 (Normal Operation [Cl. 19] a) General & Operation) |
- |
|
|
|
| 19 (b) Electric Strength) |
- |
|
|
|
| 19 (c)Temperature-rise ) |
- |
|
|
|
| 14.3 (d)Test for arcing and sparking [Cl 14.3]) |
- |
|
|
|
| 19.2 (Normal Operation (For AX type Switches) [Cl. 19.2]) |
- |
|
|
|
| 20 (Mechanical Strength Test [Cl. 20]) |
- |
|
|
|
| 21 (Resistance to Heat [Cl.21]) |
- |
|
|
|
| 22 (Screw, Current Carrying Part And Connection [Cl.22]) |
- |
|
|
|
| 22.1 (i) Screw & Nuts [Cl.22.1]) |
- |
|
|
|
| 22.4 (ii) Screw & rivets [Cl . 22.4]) |
- |
|
|
|
| 22.5 (iv) Current carrying part [Cl.22.5]) |
- |
|
|
|
| 23.2 (Creepage distances, clearances and distance through sealing compound [Cl.23]) |
- |
|
|
|
| 24.1.1 (Resistance to Abnormal Heat & Fire [Cl.24.1] [Glow Wire Test] [Cl.24.1.1]) |
- |
|
|
|
| 24.2 (Resistance to tracking [For Switch other than ordinary] [Cl.24.2]) |
- |
|
|
|
| 6 (Rating) |
- |
|
|
|
| 7 (Classification) |
- |
|
|
|
| 21 (Resistance to Heat [Cl.21]) |
- |
|
|
|
| 21 (Resistance to Heat [Cl.21]) |
- |
|
|
|
| 23.2 (Creepage distances, clearances and distance through sealing compound [Cl.23]) |
- |
|
|
|
| 22.3 (iii) Electrical Connections [Cl.22.3]) |
- |
|
|
|
| 25 of IS 3854 : 1997 (Resistance to rusting) |
- |
|
|
|
| 8 (Marking) |
- |
|
|
|
|
- |
- - |
| 957 |
IS 1489 : Part 2 (2015) |
Portland - Pozzolana cement - Specification: Part 2 calcined clay based |
- |
Rs.8420/- View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 7 -Table 2- i (Fineness 4031 Part 2) |
- |
|
|
|
| 7 -Table 2- ii- a (Expansion by Le Chatelier- 4031 Part 3) |
- |
|
|
|
| 7 -Table 2- ii- b (Expansion by Autoclave- 4031 Part 3) |
- |
|
|
|
| 7 -Table 2- iii- a (Setting Time Initial- 4031 Part 5) |
- |
|
|
|
| 7 -Table 2-iii- b (Setting Time Final- 4031 Part 5) |
- |
|
|
|
| 7 -Table 2- iv- a (Compressive Strength At 72 hrs ± 1 hr - IS 4031 Part 6) |
- |
|
|
|
| 7 -Table 2- iv- b (Compressive Strength At 168 hrs ± 2 hr - IS 4031 Part 6) |
- |
|
|
|
| 7 -Table 2- iv- c (Compressive Strength At 672 hrs ± 4 hr - IS 4031 Part 6) |
- |
|
|
|
| 7 -Table 2- vi (Drying Shrinkage- IS 4031 Part 10) |
- |
|
|
|
| 6 - Table - 1 i (Insoluble residue - Cl 7.4 of IS 4032:1985) |
- |
|
|
|
| 6 - Table - 1 ii (Magnesia - Cl 7.2 of IS 4032:1985) |
- |
|
|
|
| 6 - Table - 1 iii (Total Sulphur Content calculated as Sulphuric Anhydride (SO3) - Cl 7.3 of IS 4032:1985) |
- |
|
|
|
| 6 - Table - 1 iv (Loss on ignition - Cl 7.1 of IS 4032:1985) |
- |
|
|
|
| 6 - Table - 1 v (Chloride content - Cl 4.13 of IS 4032:1985) |
- |
|
|
|
| 6 - Table - 1 vi ( Alkali content as (Na2O + 0.658 K2O) - Cl 4.11 of IS 4032:1985) |
- |
|
|
|
|
- |
- Excluding Table 1,Clause 6.1 ,sl. no.(vi) , alkali content; |
| 958 |
IS 1293 (2019) |
Plugs and socket - Outlets of rated Voltage up to and including 250 Volts and rated current up to and including 16 amperes - Specification (Third Revision) |
- |
- View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 6 (Ratings) |
- |
|
|
|
| 6 (Ratings) |
- |
|
|
|
| 6 (Ratings) |
- |
|
|
|
| 7.1.1 (Accessories Classification) |
- |
|
|
|
| 7.1.2 (Accessories Classification) |
- |
|
|
|
| 7.1.3 (Accessories Classification) |
- |
|
|
|
| 7.1.4 (Accessories Classification) |
- |
|
|
|
| 7.2.1 (Socket-Outlets Classification) |
- |
|
|
|
| 7.2.2 (Socket-Outlets Classification) |
- |
|
|
|
| 7.2.3 (Socket-Outlets Classification) |
- |
|
|
|
| 7.2.4 (Socket-Outlets Classification) |
- |
|
|
|
| 7.3 (Plug Classification) |
- |
|
|
|
| 8.1 (MARKING) |
- |
|
|
|
| 8.8 (MARKING) |
- |
|
|
|
| 8.9 (MARKING) |
- |
|
|
|
| 9.1 (CHECKING OF DIMENSIONS) |
- |
|
|
|
| 9.2 (CHECKING OF DIMENSIONS) |
- |
|
|
|
| 10.1 (PROTECTION AGAINST ELECTRIC SHOCK) |
- |
|
|
|
| 10.1 (PROTECTION AGAINST ELECTRIC SHOCK) |
- |
|
|
|
| 10.4 (PROTECTION AGAINST ELECTRIC SHOCK) |
- |
|
|
|
| 10.5 (PROTECTION AGAINST ELECTRIC SHOCK) |
- |
|
|
|
| 10.6 (PROTECTION AGAINST ELECTRIC SHOCK) |
- |
|
|
|
| 10.7 (PROTECTION AGAINST ELECTRIC SHOCK) |
- |
|
|
|
| 11.1 (PROVISIONS FOR EARTHING) |
- |
|
|
|
| 11.2 (PROVISIONS FOR EARTHING) |
- |
|
|
|
| 11.3 (PROVISIONS FOR EARTHING) |
- |
|
|
|
| 11.4 (PROVISIONS FOR EARTHING) |
- |
|
|
|
| 11.5 (PROVISIONS FOR EARTHING) |
- |
|
|
|
| 11.6 (PROVISIONS FOR EARTHING) |
- |
|
|
|
| 12.1.1 (TERMINALS) |
- |
|
|
|
| 12.1.2 (TERMINALS) |
- |
|
|
|
| 12.2.1 (TERMINALS) |
- |
|
|
|
| 12.2.2 (TERMINALS) |
- |
|
|
|
| 12.2.3 (TERMINALS) |
- |
|
|
|
| 12.2.4 (TERMINALS) |
- |
|
|
|
| 12.2.5 (TERMINALS) |
- |
|
|
|
| 12.2.6 (TERMINALS) |
- |
|
|
|
| 12.2.7 (TERMINALS) |
- |
|
|
|
| 12.2.8 (TERMINALS) |
- |
|
|
|
| 12.2.9 (TERMINALS) |
- |
|
|
|
| 12.2.10 (TERMINALS) |
- |
|
|
|
| 12.2.11 (TERMINALS) |
- |
|
|
|
| 12.3.1 (TERMINALS) |
- |
|
|
|
| 12.3.2 (TERMINALS) |
- |
|
|
|
| 12.3.3 (TERMINALS) |
- |
|
|
|
| 12.3.4 (TERMINALS) |
- |
|
|
|
| 12.3.5 (TERMINALS) |
- |
|
|
|
| 12.3.6 (TERMINALS) |
- |
|
|
|
| 12.3.7 (TERMINALS) |
- |
|
|
|
| 12.3.8 (TERMINALS) |
- |
|
|
|
| 12.3.9 (TERMINALS) |
- |
|
|
|
| 12.3.10 (TERMINALS) |
- |
|
|
|
| 12.3.11 (TERMINALS) |
- |
|
|
|
| 12.3.12 (TERMINALS) |
- |
|
|
|
| 13.1 (CONSTRUCTIONS OF FIXED SOCKETOUTLETS) |
- |
|
|
|
| 13.2 (CONSTRUCTIONS OF FIXED SOCKETOUTLETS) |
- |
|
|
|
| 13.3 (CONSTRUCTIONS OF FIXED SOCKETOUTLETS) |
- |
|
|
|
| 13.4 (CONSTRUCTIONS OF FIXED SOCKETOUTLETS) |
- |
|
|
|
| 13.5 (CONSTRUCTIONS OF FIXED SOCKETOUTLETS) |
- |
|
|
|
| 13.6 (CONSTRUCTIONS OF FIXED SOCKETOUTLETS) |
- |
|
|
|
| 13.7 (CONSTRUCTIONS OF FIXED SOCKETOUTLETS) |
- |
|
|
|
| 13.8 (CONSTRUCTIONS OF FIXED SOCKETOUTLETS) |
- |
|
|
|
| 13.9 (CONSTRUCTIONS OF FIXED SOCKETOUTLETS) |
- |
|
|
|
| 13.1 (CONSTRUCTIONS OF FIXED SOCKETOUTLETS) |
- |
|
|
|
| 13.11 (CONSTRUCTIONS OF FIXED SOCKETOUTLETS) |
- |
|
|
|
| 13.12 (CONSTRUCTIONS OF FIXED SOCKETOUTLETS) |
- |
|
|
|
| 13.13 (CONSTRUCTIONS OF FIXED SOCKETOUTLETS) |
- |
|
|
|
| 13.14 (CONSTRUCTIONS OF FIXED SOCKETOUTLETS) |
- |
|
|
|
| 13.15 (CONSTRUCTIONS OF FIXED SOCKETOUTLETS) |
- |
|
|
|
| 13.16 (CONSTRUCTIONS OF FIXED SOCKETOUTLETS) |
- |
|
|
|
| 13.17 (CONSTRUCTIONS OF FIXED SOCKETOUTLETS) |
- |
|
|
|
| 13.18 (CONSTRUCTIONS OF FIXED SOCKETOUTLETS) |
- |
|
|
|
| 13.19 (CONSTRUCTIONS OF FIXED SOCKETOUTLETS) |
- |
|
|
|
| 13.2 (CONSTRUCTIONS OF FIXED SOCKETOUTLETS) |
- |
|
|
|
| 13.21 (CONSTRUCTIONS OF FIXED SOCKETOUTLETS) |
- |
|
|
|
| 13.22 (CONSTRUCTIONS OF FIXED SOCKETOUTLETS) |
- |
|
|
|
| 13.23 (CONSTRUCTIONS OF FIXED SOCKETOUTLETS) |
- |
|
|
|
| 14.1 (CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
|
|
|
| 14.2 (CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
|
|
|
| 14.3 (CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
|
|
|
| 14.4 (CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
|
|
|
| 14.5 (CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
|
|
|
| 14.6 (CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
|
|
|
| 14.7 (CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
|
|
|
| 14.8 (CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
|
|
|
| 14.9 (CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
|
|
|
| 14.1 (CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
|
|
|
| 14.11 (CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
|
|
|
| 14.12 (CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
|
|
|
| 14.13 (CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
|
|
|
| 14.14 (CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
|
|
|
| 14.15 (CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
|
|
|
| 14.16 (CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
|
|
|
| 14.17 (CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
|
|
|
| 14.18 (CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
|
|
|
| 14.19 (CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
|
|
|
| 14.2 (CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
|
|
|
| 14.21 (CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
|
|
|
| 14.22 (CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
|
|
|
| 14.23 (CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
|
|
|
| 14.23.1 (CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
|
|
|
| 14.23.2 (CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
|
|
|
| 14.24 (CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
|
|
|
| 14.25 (CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
|
|
|
| 14.26 (CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
|
|
|
| 15 (INTERLOCKED SOCKET-OUTLETS) |
- |
|
|
|
| 16.1 (RESISTANCE TO AGEING,) |
- |
|
|
|
| 16.2 (RESISTANCE TO HARMFUL INGRESS OF WATER AND TO HUMIDITY) |
- |
|
|
|
| 16.3 (Resistance to Humidity) |
- |
|
|
|
| 17.1 (INSULATION RESISTANCE AND ELECTRIC STRENGTH) |
- |
|
|
|
| 17.2 (INSULATION RESISTANCE AND ELECTRIC STRENGTH) |
- |
|
|
|
| 19 (TEMPERATURE RISE) |
- |
|
|
|
| 20 (BREAKING CAPACITY) |
- |
|
|
|
| 21 (NORMAL OPERATION) |
- |
|
|
|
| 21 (NORMAL OPERATION) |
- |
|
|
|
| 21 (NORMAL OPERATION) |
- |
|
|
|
| 22.1 (Verification of the Maximum Withdrawal Force) |
- |
|
|
|
| 22.2 (Verification of Minimum Withdrawal Force) |
- |
|
|
|
| 23.1 (FLEXIBLE CABLES AND THEIR CONNECTION) |
- |
|
|
|
| 23.3 (FLEXIBLE CABLES AND THEIR CONNECTION) |
- |
|
|
|
| 23.4 (FLEXIBLE CABLES AND THEIR CONNECTION) |
- |
|
|
|
| 24.1 (MECHANICAL STRENGTH
For all kinds of fixed socket-outlets
) |
- |
|
|
|
| 24.1 (MECHANICAL STRENGTH
For Plug
(1) with enclosures, covers or bodies of thermoplastic or elastomeric material) |
- |
|
|
|
| 24.1 (MECHANICAL STRENGTH
For surface mounting boxes) |
- |
|
|
|
| 24.2 (MECHANICAL STRENGTH
For portable single socket-outlets:
1) with enclosures, covers or bodies other than thermoplastic or elastomeric material) |
- |
|
|
|
| 24.2 (MECHANICAL STRENGTH
For portable multiple and combined socket outlets:
1) with enclosures, covers and bodies of elastomeric or thermoplastic material) |
- |
|
|
|
| 24.2 (MECHANICAL STRENGTH
For plug
1) with enclosures, covers and bodies other than elastomeric or thermoplastic material) |
- |
|
|
|
| 24.2 (MECHANICAL STRENGTH
For plug
1) with enclosures, covers and bodies of elastomeric or thermoplastic material) |
- |
|
|
|
| 24.3 (MECHANICAL STRENGTH
for fixed socket-outlets with a main part intended to be mounted directly on a surface) |
- |
|
|
|
| 24.4 (MECHANICAL STRENGTH
For portable single socket-outlets:
1) with enclosures, covers or bodies of thermoplastic or elastomeric material) |
- |
|
|
|
| 24.4 (MECHANICAL STRENGTH
For portable multiple and combined socket outlets:
1) with enclosures, covers and bodies of elastomeric or thermoplastic material) |
- |
|
|
|
| 24.4 (MECHANICAL STRENGTH
For Plug
1) with enclosures, covers and bodies of elastomeric or thermoplastic material) |
- |
|
|
|
| 24.5 (MECHANICAL STRENGTH
For portable single socket-outlets:
1) with enclosures, covers or bodies of thermoplastic or elastomeric material) |
- |
|
|
|
| 24.5 (MECHANICAL STRENGTH
For portable multiple and combined socket outlets:
1) with enclosures, covers and bodies of elastomeric or thermoplastic material) |
- |
|
|
|
| 24.5 (MECHANICAL STRENGTH
For Plug
1) with enclosures, covers and bodies of elastomeric or thermoplastic material) |
- |
|
|
|
| 24.6 (MECHANICAL STRENGTH
For screwed glands of accessories having an IP code higher than IP20) |
- |
|
|
|
| 24.7 (MECHANICAL STRENGTH
For plug pins provided with insulating sleeves) |
- |
|
|
|
| 24.8 (MECHANICAL STRENGTH
For shuttered socket-outlets) |
- |
|
|
|
| 24.9 (MECHANICAL STRENGTH
For portable multiple and combined socket outlets
(1) with enclosures, covers or bodies other than thermoplastic or elastomeric material) |
- |
|
|
|
| 24.1 (MECHANICAL STRENGTH
For Plug
(1) with enclosures, covers or bodies other than thermoplastic or elastomeric material) |
- |
|
|
|
| 24.11 (MECHANICAL STRENGTH
For portable socket-outlets having means for suspension on a wall) |
- |
|
|
|
| 24.12 (MECHANICAL STRENGTH
For portable socket-outlets having means for suspension on a wall) |
- |
|
|
|
| 24.13 (MECHANICAL STRENGTH
For portable socket-outlets having means for suspension on a wall) |
- |
|
|
|
| 24.14.1 (MECHANICAL STRENGTH
For fixed socket-outlets) |
- |
|
|
|
| 24.14.2 (MECHANICAL STRENGTH
For fixed socket-outlets) |
- |
|
|
|
| 25.1 (RESISTANCE TO HEAT
Accessories and surface mounting boxes) |
- |
|
|
|
| 25.2 (RESISTANCE TO HEAT
Parts of insulating material necessary to retain
current-carrying parts of the earthing circuit in position,
as well as parts of the front surface zone of thermoplastic material) |
- |
|
|
|
| 25.3 (RESISTANCE TO HEAT
Parts of insulating material not necessary to retain current-carrying parts and parts of the earthing circuit in position, even though they are in contact with them) |
- |
|
|
|
| 25.4 (RESISTANCE TO HEAT
) |
- |
|
|
|
| 26.1 (SCREWS, CURRENT-CARRYING PARTS AND CONNECTIONS) |
- |
|
|
|
| 27.1 (CREEPAGE DISTANCES, CLEARANCES AND DISTANCES THROUGH SEALING COMPOUND) |
- |
|
|
|
| 27.2 (CREEPAGE DISTANCES, CLEARANCES AND DISTANCES THROUGH SEALING COMPOUND) |
- |
|
|
|
| 27.3 (CREEPAGE DISTANCES, CLEARANCES AND DISTANCES THROUGH SEALING COMPOUND) |
- |
|
|
|
| 28.1.1 (Resistance to Abnormal Heat and to Fire
Glow-Wire Test) |
- |
|
|
|
| 28.1.2 (Resistance to Abnormal Heat and to Fire
for plugs with pins provided with insulating sleeves) |
- |
|
|
|
| 28.2 (Resistance to Tracking
For accessories other than IP code higher than IPX0 parts of insulating material retaining live parts in position) |
- |
|
|
|
| 29 (RESISTANCE TO RUSTING) |
- |
|
|
|
| 30.1 (ADDITIONAL TESTS ON PINS PROVIDED WITH INSULATING SLEEVES
Pressure Test at High Temperature) |
- |
|
|
|
| 30.2 (ADDITIONAL TESTS ON PINS PROVIDED WITH INSULATING SLEEVES
Static Damp Heat Test) |
- |
|
|
|
| 30.3 (ADDITIONAL TESTS ON PINS PROVIDED WITH INSULATING SLEEVES
Tests at Low Temperature) |
- |
|
|
|
| 30.4 (ADDITIONAL TESTS ON PINS PROVIDED WITH INSULATING SLEEVES
Impact Test at Low Temperature) |
- |
|
|
|
| 7.1.5 (Accessories Classification) |
- |
|
|
|
| 8.1 (MARKING) |
- |
|
|
|
| 10.1 (PROTECTION AGAINST ELECTRIC SHOCK) |
- |
|
|
|
| 23.2 (FLEXIBLE CABLES AND THEIR CONNECTION) |
- |
|
|
|
|
- |
- - |
| 959 |
IS 12818 (2010) |
Unplasticized polyvinyl chloride (Pvc - U) screen and casing pipes for bore/tubewells - Specification (Second Revision) |
- |
Rs.6450.00 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 9.5 (Tensile Strength
IS 12235(Part 13)) |
- |
|
|
|
| 9.6 (Vicat Softening Temperature
IS 12235 (Part 2).) |
- |
|
|
|
| 9.3 (Density
IS 12235 (Part 14)) |
- |
|
|
|
| 9.1 ( Visual Appearance) |
- |
|
|
|
| 7.2 and Table 5, 6 & 7
Fig 1B (Wall thickness, Max) |
- |
|
|
|
| 7.2 and Table 5, 6 & 7
Fig 1B (Wall thickness, Min) |
- |
|
|
|
| 7.1, 7.2 and Table 5, 6 & 7 Fig 1B (Mean outside dia over connection,mm (Take 4 reading and maximum valu reported)) |
- |
|
|
|
| 7.1 and Table 1, 2, 3, & 4
Fig 1A & 1B (Wall thickness) |
- |
|
|
|
|
- |
- Excluding Test facility not avaialble for Cl 9.4 Resistance to External Blows ,9.7 Effect on Water; |
| 960 |
IS 2029 (1998) |
Ring wrenches (Spanners) - Specification (Fourth Revision) |
- |
Rs.3700/- View breakup
Total Rs.300x12+100 = Rs.3700.00
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl.4 (CARBON) |
- |
|
|
|
| Cl.4 (SULPHUR) |
- |
|
|
|
| Cl.4 (PHOSPHURS) |
- |
|
|
|
| Cl.4 (MANGANESE) |
- |
|
|
|
| Cl.4 (NITROGEN) |
- |
|
|
|
| Cl.4 (SILICON) |
- |
|
|
|
| Cl.4 (ALUMINIUM) |
- |
|
|
|
| Cl.4 (CHROMIUM) |
- |
|
|
|
| Cl.4 (NICKEL) |
- |
|
|
|
| Cl.4 (VANADIUM) |
- |
|
|
|
| Cl.4 (MOLYBDENUM) |
- |
|
|
|
| 3, Table-1 (Dimensions- s1) |
- |
|
|
|
| 3, Table-1 (Dimensions- s2) |
- |
|
|
|
| 3, Table-1 (Dimensions- a) |
- |
|
|
|
| 3, Table-1 (Dimensions- b1) |
- |
|
|
|
| 3, Table-1 (Dimensions- b2) |
- |
|
|
|
| 3, Table-1 (Dimensions- L) |
- |
|
|
|
| 5 (Hardness) |
- |
|
|
|
| 6 (Workmanship and Finish) |
- |
|
|
|
| 6 (Torque Testing) |
- |
|
|
|
| 7 (Designation) |
- |
|
|
|
|
- |
- Grade designation of material as per relevant IS may please declared.;
Excluding -; torque test |