| 961 |
IS 2029 (1998) |
Ring wrenches (Spanners) - Specification (Fourth Revision) |
- |
Rs.3700/- View breakup
Total Rs.300x12+100 = Rs.3700.00
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl.4 (CARBON) |
- |
|
|
|
| Cl.4 (SULPHUR) |
- |
|
|
|
| Cl.4 (PHOSPHURS) |
- |
|
|
|
| Cl.4 (MANGANESE) |
- |
|
|
|
| Cl.4 (NITROGEN) |
- |
|
|
|
| Cl.4 (SILICON) |
- |
|
|
|
| Cl.4 (ALUMINIUM) |
- |
|
|
|
| Cl.4 (CHROMIUM) |
- |
|
|
|
| Cl.4 (NICKEL) |
- |
|
|
|
| Cl.4 (VANADIUM) |
- |
|
|
|
| Cl.4 (MOLYBDENUM) |
- |
|
|
|
| 3, Table-1 (Dimensions- s1) |
- |
|
|
|
| 3, Table-1 (Dimensions- s2) |
- |
|
|
|
| 3, Table-1 (Dimensions- a) |
- |
|
|
|
| 3, Table-1 (Dimensions- b1) |
- |
|
|
|
| 3, Table-1 (Dimensions- b2) |
- |
|
|
|
| 3, Table-1 (Dimensions- L) |
- |
|
|
|
| 5 (Hardness) |
- |
|
|
|
| 6 (Workmanship and Finish) |
- |
|
|
|
| 6 (Torque Testing) |
- |
|
|
|
| 7 (Designation) |
- |
|
|
|
|
- |
- Grade designation of material as per relevant IS may please declared.;
Excluding -; torque test |
| 962 |
IS 8944 (2005) |
Chlorpyrifos, emulsifiable concentrates - Specification (First Revision) |
- |
- View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 3.2.1 (Description) |
- |
|
|
|
| 3.2.2 (Cold Test) |
- |
|
|
|
| 3.2.3 (Flash Point (Abel)) |
- |
|
|
|
| 3.2.4 (Emulsion Stability) |
- |
|
|
|
| 3.3.1 (Chloropyrifos content) |
- |
|
|
|
| 3.3.2 (Acidity (as H2SO4), ) |
- |
|
|
|
|
- |
- Excluding Cl. 3.3.1 Content; |
| 963 |
IS 9798 (2013) |
Low pressure regulators for use with liquefied petroleum gas (LPG) - Specification (Second Revision) |
- |
14276 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4.2
IS 742 (Material) |
- |
|
|
|
| 4.1.1
IS 2305 (Material) |
- |
|
|
|
| 4.2.1a (Finish) |
- |
|
|
|
| 4.2.1b
IS 9844
IS 6009 (Finish) |
- |
|
|
|
| 4.3.1 (Diaphragm Material) |
- |
|
|
|
| 4.3.2
IS 3400(Part 4) (The material shall not show change of more than 10 IRHD when subjected to ageing of 72 h at 70°C in accordance with the method prescribed in 3 or 4 of IS 3400 (Part 4)) |
- |
|
|
|
| 4.3.3 (Clamping test) |
- |
|
|
|
| 4.3.4
Annex C (Bursting & Pull out test) |
- |
|
|
|
| 4.3.5ai
Annex D (The material shall, after immersion in n-pentane or octet commercial LPG for 72 h, meet the appropriate requirements specified in Annex D
Diaphragm: Extractable
) |
- |
|
|
|
| 4.3.5b
IS 3400(Part 2) (Changes in hardness, before and after the immersion ) |
- |
|
|
|
| 4.3.7
Annex E (The material shall have 25 percent max compression set when subjected to compression set test in accordance with the method prescribed in Annex E.) |
- |
|
|
|
| 4.4.1 (Valve Pad Material) |
- |
|
|
|
| 4.4.2ai
Annex D (The material shall, after immersion in n-pentane or octet commercial LPG for 72 h, meet the appropriate requirements specified in Annex D
Extractable
) |
- |
|
|
|
| 4.4.2aii
Annex D ( Absorbed) |
- |
|
|
|
| 4.4.2b
IS 3400(Part 2) (Changes in hardness, before and after the test) |
- |
|
|
|
| 4.4.3
IS 3400(Part 4) (The material shall not show change of more than 10 IRHD when subjected to ageing of 72 h at 70°C in accordance with the method prescribed in 3 or 4 of IS 3400 (Part 4)) |
- |
|
|
|
| 4.4.4 (Valve Pad Material) |
- |
|
|
|
| 4.4.5
Annex E (The material shall have 40 percent max compression set when subjected to compression set test in accordance with the method prescribed in Annex E.) |
- |
|
|
|
| 4.5,4.4.1 (Seals
O rings and rubber components other than diaphragm
and valve pad ) |
- |
|
|
|
| 4.5,4.4.2i
Annex D (The material shall, after immersion in n-pentane or octet commercial LPG for 72 h, meet the appropriate requirements specified in Annex D
Extractable
) |
- |
|
|
|
| 4.5,4.4.2ii
Annex D ( Absorbed) |
- |
|
|
|
| 4.5,4.4.2b
IS 3400(Part 2) (Changes in hardness, before and after the test) |
- |
|
|
|
| 4.5,4.4.3
IS 3400(Part 4) (The material shall not show change of more than 10 IRHD when subjected to ageing of 72 h at 70°C in accordance with the method prescribed in 3 or 4 of IS 3400 (Part 4)) |
- |
|
|
|
| 4.5,4.4.5
Annex E (The material shall have 40 percent max compression set when subjected to compression set test in accordance with the method prescribed in Annex E.) |
- |
|
|
|
| 4.5,4.4.1 (Seals
O rings and rubber components other than diaphragm
and valve pad ) |
- |
|
|
|
| 4.5,4.4.2i
Annex D (The material shall, after immersion in n-pentane or octet commercial LPG for 72 h, meet the appropriate requirements specified in Annex D
Extractable
) |
- |
|
|
|
| 4.5,4.4.2ii
Annex D ( Absorbed) |
- |
|
|
|
| 4.5,4.4.2b
IS 3400(Part 2) (Changes in hardness, before and after the test) |
- |
|
|
|
| 4.5,4.4.3
IS 3400(Part 4) (The material shall not show change of more than 10 IRHD when subjected to ageing of 72 h at 70°C in accordance with the method prescribed in 3 or 4 of IS 3400 (Part 4)) |
- |
|
|
|
| 4.5,4.4.5
Annex E (The material shall have 40 percent max compression set when subjected to compression set test in accordance with the method prescribed in Annex E.) |
- |
|
|
|
| 4.5,4.4.1 (Seals
O rings and rubber components other than diaphragm
and valve pad ) |
- |
|
|
|
| 4.5,4.4.2i
Annex D (The material shall, after immersion in n-pentane or octet commercial LPG for 72 h, meet the appropriate requirements specified in Annex D
Extractable
) |
- |
|
|
|
| 4.5,4.4.2ii
Annex D ( Absorbed) |
- |
|
|
|
| 4.5,4.4.2b
IS 3400(Part 2) (Changes in hardness, before and after the test) |
- |
|
|
|
| 4.5,4.4.3
IS 3400(Part 4) (The material shall not show change of more than 10 IRHD when subjected to ageing of 72 h at 70°C in accordance with the method prescribed in 3 or 4 of IS 3400 (Part 4)) |
- |
|
|
|
| 4.5,4.4.5
Annex E (The material shall have 40 percent max compression set when subjected to compression set test in accordance with the method prescribed in Annex E.) |
- |
|
|
|
| 5.2 (Construction and Workmanship) |
- |
|
|
|
| 5.5 (Inlet Connection) |
- |
|
|
|
| 5.5 (Inlet Connection) |
- |
|
|
|
| 5.5 (Inlet Connection) |
- |
|
|
|
| 5.6,5.6.1 (Outlet Connection:-
Non-threaded Outlet Connection) |
- |
|
|
|
| 5.7 (Body) |
- |
|
|
|
| 5.8 (Vent) |
- |
|
|
|
| 5.10.1 (Valve Pad Fitting) |
- |
|
|
|
| 5.11.1,8.11
Table 1 (The fixing of the inlet connection on to the regulator body , whether it is of the threaded or non - threaded type or in one piece, shall withstand the following tests, under the conditions defined in 8.11 (see Table 1)) |
- |
|
|
|
| 5.11.1,8.11
Table 1 (The fixing of the inlet connection on to the regulator body , whether it is of the threaded or non - threaded type or in one piece, shall withstand the following tests, under the conditions defined in 8.11 (see Table 1)) |
- |
|
|
|
| 5.12.1,8.11
Table 3 (The regulators when installed as indicated in the installation instruction shall resist the following tests under the conditions defined in 8.11 (see Table 3 )) |
- |
|
|
|
| 5.11.2a,8.11
Table 2 (The fixing of the outlet connection on to the regulator body, whether it is of the threaded, or non-threaded type or in one piece, shall resist the following tests, under the conditions defined in 8.11 (see Table 2):a)For non - threaded hose connection) |
- |
|
|
|
| 5.11.2b,8.11
Table 2 (The fixing of the outlet connection on to the regulator body, whether it is of the threaded, or non-threaded type or in one piece, shall resist the following tests, under the conditions defined in 8.11 (see Table 2):b)For threaded unions) |
- |
|
|
|
| 6,6.1,6.2 (SOUNDNESS) |
- |
|
|
|
| 6,6.1,6.2 (SOUNDNESS) |
- |
|
|
|
| 6.3 (SOUNDNESS) |
- |
|
|
|
| 6.4 (SOUNDNESS) |
- |
|
|
|
| 8.2 (CHATTER) |
- |
|
|
|
| 8.9 (Performance
(Before Cycle test, Low Temp. Test and High Temp. Test)
Inlet Pressure Flow Rate
) |
- |
|
|
|
| 8.9 (0.5 kgf/cm2 100 % ) |
- |
|
|
|
| 8.9 (17 kgf/cm2 10 % ) |
- |
|
|
|
| 8.9 (Static(lock up) pressure) |
- |
|
|
|
| 8.9 (Performance
(Before Cycle test, Low Temp. Test and High Temp. Test)
Inlet Pressure Flow Rate
) |
- |
|
|
|
| 8.10.1
Annex G (Cycle Test) |
- |
|
|
|
| 6,6.1,6.2 (SOUNDNESS
(After Cycle Test)) |
- |
|
|
|
| 8.9 (Performance
(After Cycle test)
Inlet Pressure Flow Rate
) |
- |
|
|
|
| 8.10.2
Annex H
8.9 (Low Temperature Test
Performance test after exposure to
temperature at -200 C for 10 Min and back
to ambient condition.
Inlet Pressure Flow Rate) |
- |
|
|
|
| 8.9 (Static(lock up) pressure) |
- |
|
|
|
| 8.10.3
Annex H
8.9 (High Temperature Test
Performance test after exposure to
temperature at 650 C for 10 Min and back
to ambient condition.
Inlet Pressure Flow Rate) |
- |
|
|
|
| 8.9 (0.5 kgf/cm2 100 % ) |
- |
|
|
|
| 8.9 (17 kgf/cm2 10 % ) |
- |
|
|
|
| 8.9 (Static(lock up) pressure) |
- |
|
|
|
| 4.4.5
Annex E (The material shall have 40 percent max compression set when subjected to compression set test in accordance with the method prescribed in Annex E.) |
- |
|
|
|
| Cl. 4.2 (Aluminium) |
- |
|
|
|
| Cl. 4.2 (Copper) |
- |
|
|
|
| Cl. 4.2 (Magnesium) |
- |
|
|
|
| Cl. 4.2 (Iron) |
- |
|
|
|
| Cl. 4.2 (Lead) |
- |
|
|
|
| Cl. 4.2 (Cadmium) |
- |
|
|
|
| Cl. 4.2 (Tin) |
- |
|
|
|
| Cl. 4.2 (Thalium+ Indium) |
- |
|
|
|
| Cl. 4.2 (Nickel) |
- |
|
|
|
| Cl. 4.2 (Zinc) |
- |
|
|
|
| Cl. 4.2 (Chromium) |
- |
|
|
|
|
- |
- - |
| 964 |
IS 1554 : Part 1 (1988) |
Specification for pvc insulated (Heavy Duty) electric cables: Part 1 for working voltages up to and including 1100 v (Third Revision) |
- |
Rs 26700 View breakup
Rs.16650/- for single core unarmoured cable, Rs.22500/- for two core, unarmoured cable, Rs.26700/- for two core armoured cable (Excluding addl. Type test for cables with improved fire performance.) For multi core cables, extra charges @ 35 % for each additional core shall be levied. Material testing charges as per relevant referred ISs Testing charges for Additional Type Tests for Improved Fire Performance Tests: Rs. 7100/- for category C1 Rs. 11700/- for category C2
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 3.1 (MATERIALS : CONDUCTOR) |
- |
|
|
|
| 4.1.1 (INSULATION : General Purjose Insulaiion) |
- |
|
|
|
| 4.1.2 (INSULATION : Heat Resisting Insulation) |
- |
|
|
|
| 5.1 (MATERIALS : FILLER AND INNER SHEATH) |
- |
|
|
|
| 6.1 (MATERIALS : ARMGURING) |
- |
|
|
|
| 7.1.1 (OUTER SHEATH : For Cables with General Purpose InsuIafion) |
- |
|
|
|
| 7.1.2 (OUTER SHEATH : For Cables with Heat Resisting InsuIalion) |
- |
|
|
|
| 8.1 (CONSTRUCTION : CONDUCTOR) |
- |
|
|
|
| 8.2 (CONSTRUCTION : CONDUCTOR) |
- |
|
|
|
| 9.2 (INSULATION : Thickness of Insulation) |
- |
|
|
|
| 9.4 (INSULATION : Application of Insulation) |
- |
|
|
|
| 10.1 (CORE IDENTIFICATION) |
- |
|
|
|
| 10.2 (CORE IDENTIFICATION) |
- |
|
|
|
| 10.3 (CORE IDENTIFICATION) |
- |
|
|
|
| 10.3.1 (Arrangement of Marking) |
- |
|
|
|
| 11.1 (LAYING UP OF CORES) |
- |
|
|
|
| 12.1 (INNER SHEATH) |
- |
|
|
|
| 12.2 (INNER SHEATH) |
- |
|
|
|
| 12.3 (INNER SHEATH :Thickness of Inner Sheath) |
- |
|
|
|
| 13.1.1 (ARMOURING : Application) |
- |
|
|
|
| 13.1.2 (Armouring: Coverage ) |
- |
|
|
|
| 13.1.3 (ARMOURING : Direction of lay ) |
- |
|
|
|
| 13.2 (ARMOURING : Type of Armour) |
- |
|
|
|
| 13.3 (Armouring : Dimensions -Wire Diameter) |
- |
|
|
|
| 13.3 (Armouring : Dimensions -Formed wire ) |
- |
|
|
|
| 13.4 (ARMOURING : Joints) |
- |
|
|
|
| 13.5.1 (ARMOURING : Resistance) |
- |
|
|
|
| 13.5.2 (ARMOURING : Resistance) |
- |
|
|
|
| 13.6 a) (ARMOURING: Tensile Strength) |
- |
|
|
|
| 13.6 b) (ARMOURING: Elongation ) |
- |
|
|
|
| 13.6 f) (ARMOURING: Mass of zinc coating ) |
- |
|
|
|
| 13.6 g) (ARMOURING: Resistivity) |
- |
|
|
|
| 14.1 (OUTER SHEATH) |
- |
|
|
|
| 14.3 (OUTER SHEATH : Colour ) |
- |
|
|
|
| 14.4.1 (Thickness of Outer Sheath : Unarmowed Cables) |
- |
|
|
|
| 14.4.2 (Thickness of Outer Sheath : Armoured Cables) |
- |
|
|
|
| 15.1 a) 1) (Tests on conductor : Annealing test ( for copper )) |
- |
|
|
|
| 15.1 a) 2) (Tensile test (for aluminium) - Before stranding ) |
- |
|
|
|
| 15.1 a) 2) (Tensile test (for aluminium) - After stranding ) |
- |
|
|
|
| 15.1 a) 3) (Tests on conductor : Wrapping test ( for aluminium )) |
- |
|
|
|
| 15.1 a) 4) (Tests on conductor : Conductor resistance test) |
- |
|
|
|
| 15.1 a) 4) (Resistance test - Neutral conductor ) |
- |
|
|
|
| 15.1 d)1) (Phyaical tests for insulation : Tensile Test) |
- |
|
|
|
| 15.1 d)1) (Phyaical tests for insulation : Elongation ) |
- |
|
|
|
| 15.1 d)1) (Physical tests for sheath : Tensile stregth ) |
- |
|
|
|
| 15.1 d)1) (Physical tests for sheath : Elongation ) |
- |
|
|
|
| 15.1 d)2) (Phyaical tests for insulation- Ageing in air Oven : Tensile Test) |
- |
|
|
|
| 15.1 d)2) (Phyaical tests for insulation - Ageing in air Oven : Tensile Variation ) |
- |
|
|
|
| 15.1 d)2) (Phyaical tests for insulation - Ageing in air oven : Elongation ) |
- |
|
|
|
| 15.1 d)2) (Phyaical tests for insulation- Ageing in air oven : Elongation Variation ) |
- |
|
|
|
| 15.1 d)2) (Physical tests for outer sheath- Ageing in air oven : Tensile stregth ) |
- |
|
|
|
| 15.1 d)2) (Physical tests for outer sheath- Ageing in air oven : Tensile stregth Variation ) |
- |
|
|
|
| 15.1 d)2) (Physical tests for outer sheath -Ageing in air oven : Elongation Variation ) |
- |
|
|
|
| 15.1 d)5) ( Loss of mass in air oven- Insulation ) |
- |
|
|
|
| 15.1 d)5) ( Loss of mass in air oven- sheath ) |
- |
|
|
|
| 15.1 d)3) (Phyaical tests for insulation : Shrinkage ) |
- |
|
|
|
| 15.1 d)3) (Phyaical tests for insulation : Shrinkage - Crack observed ) |
- |
|
|
|
| 15.1 d)3) (Phyaical tests for Sheath : Shrinkage ) |
- |
|
|
|
| 15.1 d)3) (Phyaical tests for Sheath : Shrinkage - Crack observed ) |
- |
|
|
|
| 15.1 d)4) (Hot deformation : Insulation ) |
- |
|
|
|
| 15.1 d)4) (Hot deformation : Sheath ) |
- |
|
|
|
| 15.1 d)6) (Heat shock test- Insulation ) |
- |
|
|
|
| 15.1 d)6) (Heat shock test- sheath ) |
- |
|
|
|
| 15.1 d)7) (Thermal stability- insulation ) |
- |
|
|
|
| 15.1 d)7) (Thermal stability- Sheath ) |
- |
|
|
|
| 15.1 e) (Insulation resistance test : Volume Resistivity ) |
- |
|
|
|
| 15.1 e) (Insulation resistance test : IR Constant ) |
- |
|
|
|
| 15.1 f) (High voltage test ( water immersion test )) |
- |
|
|
|
| 15.1 g) (High voltage test at room temperature) |
- |
|
|
|
| 16.4 (Flammability Test) |
- |
|
|
|
| 15.4 a) (Cold bend test- Insulation ( Optional test)) |
- |
|
|
|
| 15.4 a) (Cold bend test- Sheath ( Optional test)) |
- |
|
|
|
| 15.4 b) (Cold impact test- Insulation ( Optional test)) |
- |
|
|
|
| 15.4 b) (Cold impact test- Sheath ( Optional test)) |
- |
|
|
|
| 15.4 c) (Armour resistance test ( for other than mining cables ).- Optional test ) |
- |
|
|
|
| 17.1 (IDENTIFICATION : Manufacturer’s Identification) |
- |
|
|
|
| 17.2 (IDENTIFICATION : Cable Identification) |
- |
|
|
|
| 17.3 (IDENTIFICATION : Cable Code) |
- |
|
|
|
| 13.6 c) (ARMOURING: Torsion Test (For round wire ) ) |
- |
|
|
|
| 13.6 d) (ARMOURING: Winding Test(For formed wire)) |
- |
|
|
|
| 13.6 e) (ARMOURING: Uniformity of zinc coating) |
- |
|
|
|
| Cl.8 (Conductor, Number of wires.) |
- |
|
|
|
| Cl.8 (Conductor, Number of wires.) |
- |
|
|
|
| Cl.8 (Flexibility class) |
- |
|
|
|
| [(Cl.15), (d), 2] (After ageing, Elongation of Sheath [Percentage]) |
- |
|
|
|
|
- |
- Except Cat C1 & C2 |
| 965 |
IS 2062 (2011) |
Hot rolled medium and high tensile structural steel - Specification (Seventh Revision) |
- |
3200 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl 18 (Weight) |
- |
|
|
|
| Cl 15 (Length, Width & Thickness) |
- |
|
|
|
| Cl 10.3 (UTM) |
- |
|
|
|
| Cl 7 (Workmanship) |
- |
|
|
|
| Cl. 5, 8.1 ,8.2. Table 1 (Grade:- E250, E275,E300 ,E350 ,E410, E450, E550,E600, E650) (Carbon- IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
|
|
|
| Cl. 5, 8.1 ,8.2. Table 1 (Grade:- E250, E275,E300 ,E350 ,E410, E450, E550,E600, E650) (Sulphur- IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
|
|
|
| Cl. 5, 8.1 ,8.2. Table 1 (Grade:- E250, E275,E300 ,E350 ,E410, E450, E550,E600, E650) (Phosphorus- IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
|
|
|
| Cl. 5, 8.1 ,8.2. Table 1 (Grade:- E250, E275,E300 ,E350 ,E410, E450, E550,E600, E650) (Manganese- IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
|
|
|
| Cl. 5, 8.1 ,8.2. Table 1 (Grade:- E250, E275,E300 ,E350 ,E410, E450, E550,E600, E650) (Silicon- IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
|
|
|
| Clause - 5, 8.1 & 8.2 (E250, ALUMINIUM) |
- |
|
|
|
| Cl. 5, 8.1 ,8.2. Table 1 (Grade:- E250, E275,E300 ,E350 ,E410, E450, E550,E600, E650) (Nitrogen- IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
|
|
|
| Cl. 5, 8.1 ,8.2. Table 1 (Grade:- E250, E275,E300 ,E350 ,E410, E450, E550,E600, E650) (Carbon Equivalent- IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
|
|
|
|
- |
- Grade/Designation, Quality type of killing and declaration regarding micro alloying elements addition may please be declared. Sample size- 5 pcs of 5 cm x 5 cm having dia> 3mm and thickness >0.8 mm;
Excluding -; Y-groove crackability test |
| 966 |
IS 1786 (2008) |
High strength deformed steel bars and wires for concretere inforcement - Specification (Fourth Revision) |
- |
25780 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl 9.4 (Load In Other Direction From Bend) |
- |
|
|
|
| Cl 9.3 (Load In One Direction) |
- |
|
|
|
| Cl 8.1 (UTM) |
- |
|
|
|
| Cl 5 (Deformations and Surface Characteristics) |
- |
|
|
|
| Cl 7.2 (Weight) |
- |
|
|
|
| 4.1 (Carbon %) |
- |
|
|
|
| 4.1 (Sulphur %) |
- |
|
|
|
| 4.1 (Phosphorus %) |
- |
|
|
|
| 4.1 (Manganese %) |
- |
|
|
|
| 4.1 ( Nitrogen%) |
- |
|
|
|
| 4.1 (Sulphur and phosphorous) |
- |
|
|
|
| 4.1 (CE) |
- |
|
|
|
|
- |
- Microalloying element/type of killing (element)/any other element to be declared;
Excluding -; Pull out test, proof stress |
| 967 |
IS 694 (2010) |
Polyvinyl chloride insulated unsheathed and sheathed cables/cords with rigid and flexible conductor for rated voltages up to and including 450/750 v (Fourth Revision) |
- |
Please see remarks View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4.1 (Conductor - Material) |
- |
|
|
|
| 4.1 (Tensile test (for Al)-Before Stranding) |
- |
|
|
|
| 4.1 (Tensile test (for Al)- After Stranding) |
- |
|
|
|
| 4.1 (Annealing test (for copper)) |
- |
|
|
|
| 4.1 (Wrapping test (for Al)) |
- |
|
|
|
| 4.2 (Conductor resistance test) |
- |
|
|
|
| 5.1 (Insulation) |
- |
|
|
|
| 5.2 (Application ) |
- |
|
|
|
| 5.3 (Thickness of Insulation) |
- |
|
|
|
| 6.1 (Filler) |
- |
|
|
|
| 6.2 (Filler) |
- |
|
|
|
| 7 (Binder Tape) |
- |
|
|
|
| 8.1 (Sheath Material ) |
- |
|
|
|
| 8.3 (Thickness of Sheath) |
- |
|
|
|
| 9 (Overall dimensions) |
- |
|
|
|
| 9.1 (Ovality) |
- |
|
|
|
| 10.1 (HV (water immersion)) |
- |
|
|
|
| 10.2 (HV (room temperature)) |
- |
|
|
|
| 10.4 (Flammability test-Burning after flame removal) |
- |
|
|
|
| 10.4 (Flammability test- Unaffected portion) |
- |
|
|
|
| 10.9 (Additional ageing test (OU cables only) -HV test (at 60±3oC)) |
- |
|
|
|
| 10.11 (Per sulphate test (for tinned Cu cable only)) |
- |
|
|
|
| 11 (Identification) |
- |
|
|
|
| 11.1 (Durability) |
- |
|
|
|
| 11.2 (Legibility) |
- |
|
|
|
| 12 (CONSTRUCTION Core Identification) |
- |
|
|
|
| Table 1 iii) c) 1) (Tensile strength (Without ageing)) |
- |
|
|
|
| Table 1 iii) c) 1) (Elongation (Without ageing)) |
- |
|
|
|
| Table 1 iii) c) 2) (Loss of mass- Insulation ) |
- |
|
|
|
| Table 1 iii) c) 3) (Tensile strength (After ageing)) |
- |
|
|
|
| Table 1 iii) c) 3) (TS variation) |
- |
|
|
|
| Table 1 iii) c) 3) (Elongation (After ageing)) |
- |
|
|
|
| Table 1 iii) c) 3) (Elongation variation) |
- |
|
|
|
| Table 1 iii) c) 4) (Shrinkage-Insulation) |
- |
|
|
|
| Table 1 iii) c) 4) (Cracks Observed) |
- |
|
|
|
| Table 1 iii) c) 5) (Heat shock-Insulation ) |
- |
|
|
|
| Table 1 iii) c) 6) (Hot deformation - Indentation depth- Insulation) |
- |
|
|
|
| Table 1 iii) c) 7) (Thermal stability- Insulation ) |
- |
|
|
|
| Table 1 iii) c) 8) (Cold bend for insulation) |
- |
|
|
|
| Table 1 iii) c) 9) (Cold impact for insulation) |
- |
|
|
|
| Table 1 iii) d) 1) (Sheath -Tensile strength (Without ageing)) |
- |
|
|
|
| Table 1 iii) d) 1) (Sheath- Elongation (Without ageing)) |
- |
|
|
|
| Table 1 iii) d) 2) (Loss of mass- Sheath ) |
- |
|
|
|
| Table 1 iii) d) 3) (Sheath- Tensile strength (After ageing)) |
- |
|
|
|
| Table 1 iii) d) 3) (Sheath- TS variation) |
- |
|
|
|
| Table 1 iii) d) 3) (Sheath- Elongation (After ageing)) |
- |
|
|
|
| Table 1 iii) d) 3) (Sheath- Elongation variation) |
- |
|
|
|
| Table 1 iii) d) 4) (Shrinkage- Sheath ) |
- |
|
|
|
| Table 1 iii) d) 4) (Cracks Observed) |
- |
|
|
|
| Table 1 iii) d) 5) (Heat shock-Sheath ) |
- |
|
|
|
| Table 1 iii) d) 6) (Hot deformation -Indentation depth - Sheath ) |
- |
|
|
|
| Table 1 iii) d) 7) (Thermal stability- Sheath ) |
- |
|
|
|
| Table 1 iii) d) 8) (Cold bend for sheath) |
- |
|
|
|
| Table 1 iii) d) 9) (Cold impact for sheath) |
- |
|
|
|
| table 1 e) 3) (Volume Resistivity - Room temp ) |
- |
|
|
|
| table 1 e) 3) (Volume Resistivity - Maximum temp) |
- |
|
|
|
| table 1 e) 3) (IR constant- Room temp ) |
- |
|
|
|
| table 1 e) 3) (IR constant- max. Temp) |
- |
|
|
|
| Table 1 iii) c) 8) (Cold bend for insulation) |
- |
|
|
|
| Table 1 iii) c) 9) (Cold impact for insulation) |
- |
|
|
|
| Table 1 iii) d) 8) (Cold bend for sheath) |
- |
|
|
|
| Table 1 iii) d) 9) (Cold impact for sheath) |
- |
|
|
|
| Table 1 (Category Code) |
- |
|
|
|
| 10.11 (Persulphate Test ) |
- |
|
|
|
| 4.1 (Conductor - Material) |
- |
|
|
|
| 4.1 (Conductor - Material) |
- |
|
|
|
| 4.1 (Conductor - Material) |
- |
|
|
|
| 8 (SHEATH) |
- |
|
|
|
| 18 (SINGLE AND MULTICORE CIRCULAR PVC INSULATED
AND SHEATHED CABLES WITH RIGID CONDUCTOR (CLASS 1 AND CLASS 2) FOR GENERAL PURPOSE ) FOR MAXIMUM CONDUCTOR TEMPERATURE (70°C OR 85°C)) |
- |
|
|
|
| 4.1 (Material) |
- |
|
|
|
| (4.3 of IS 8130:2013) (Form of Conductor) |
- |
|
|
|
| ( 4.4.1 of IS 8130:2013) (Joints in Conductor) |
- |
|
|
|
| (4.4.2 of IS 8130:2013) (Joints in Conductor Solid Conductors (Aluminium Conductors only)) |
- |
|
|
|
| (Cl.6.1.1 of IS 8130:2013) (Solid Conductor (Class 1)) |
- |
|
|
|
| (Cl.6.1.2 of IS 8130:2013) (Solid Conductor (Class 1)) |
- |
|
|
|
| (Cl.6.1.3 of IS 8130:2013) (Solid Conductor (Class 1)) |
- |
|
|
|
| (6.2.1 of IS 8130:2013) (Stranded Circular Non-compacted Conductors (Class 2)) |
- |
|
|
|
| (6.2.2 of IS 8130:2013) (Stranded Circular Non-compacted Conductors (Class 2)) |
- |
|
|
|
| (6.2.3 of IS 8130:2013) (Stranded Circular Non-compacted Conductors (Class 2)) |
- |
|
|
|
| (6.3.1 of IS 8130:2013) (Stranded Compacted Circular Conductors and Shaped Conductors (Class 2)) |
- |
|
|
|
| (6.3.2 of IS 8130:2013) (Stranded Compacted Circular Conductors and Shaped Conductors (Class 2)) |
- |
|
|
|
| (6.3.3 of IS 8130:2013) (Stranded Compacted Circular Conductors and Shaped Conductors (Class 2)) |
- |
|
|
|
| ( 6.4.1 of IS 8130:2013) (Flexible Conductors (Class 5)) |
- |
|
|
|
| (6.4.2 of IS 8130:2013) (Flexible Conductors (Class 5)) |
- |
|
|
|
| ( 6.4.3 of IS 8130:2013) (Flexible Conductors (Class 5)) |
- |
|
|
|
| Cl.19.1.4 (Assembly of Cores) |
- |
|
|
|
| Cl. 8.2 (Application of Sheath) |
- |
|
|
|
|
- |
- Test facility not available for FR, FR-LSH category. |
| 968 |
IS 15658 (2006) |
Precast concrete blocks for paving - Specification |
- |
Rs.15940/- View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 6.2.4 (WATER ABSORPTION TEST (Average for three test specimens)) |
- |
|
|
|
| 6.2.5 (AVERAGE COMPRESSIVE STRENGTH (Average for eight test specimens) ) |
- |
|
|
|
|
- |
- Excluding -; Abrasion Resistance Test a ( Dry & Wet) |
| 969 |
IS 269 (2015) |
Ordinary portland cement - Specification (Sixth Revision) |
- |
- View breakup
Testing charges) for the product are: i) Including Transverse Strength (optional test) test 9,700.00 ii) Excluding Transverse Strength (optional test) test 8,500.00 -Testing charges for only chemical test report: 4,900.00 -Testing charges for only physical test report including optional tests: 4,800.00 -Testing charges for only physical test report excluding optional tests: 3,600.00
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 6.1 Table-2 viii (Alkali content) |
- |
|
|
|
| 6.1 Table-2 vii (Chloride content) |
- |
|
|
|
| 6.1 Table-2 vi (Loss on ignition) |
- |
|
|
|
| 6.1 Table-2 v (Total Sulphur Content calculated as Sulphuric Anhydride) |
- |
|
|
|
| 6.1 Table-2 iv (Magnesia) |
- |
|
|
|
| 6 - Table - 1 i (Ratio of percentage of lime to percentages of silica, alumina and iron oxide - Cl 4 of IS 4032:1985) |
- |
|
|
|
| 6.1 Table-2 iii. (Insoluble residue) |
- |
|
|
|
| 6.1 Table-2 ii. (Ratio of percentage of alumina to that of iron oxide) |
- |
|
|
|
| 6.1 Table-2 viii (Alkali content) |
- |
|
|
|
| 6.1 Table-2 vii (Chloride content) |
- |
|
|
|
| 6.1 Table-2 vi (Loss on ignition) |
- |
|
|
|
| 6.1 Table-2 v (Total Sulphur Content calculated as Sulphuric Anhydride) |
- |
|
|
|
| 6.1 Table-2 iv (Magnesia) |
- |
|
|
|
| 6 - Table - 1 i (Ratio of percentage of lime to percentages of silica, alumina and iron oxide - Cl 4 of IS 4032:1985) |
- |
|
|
|
| 6.1 Table-2 iii. (Insoluble residue) |
- |
|
|
|
| 6.1 Table-2 ii. (Ratio of percentage of alumina to that of iron oxide) |
- |
|
|
|
| 7 Table-3 iv c (Compressive Strength At 672 hrs ± 4 hr - IS 4031 Part 6) |
- |
|
|
|
| 7 Table-3 iv b (Compressive Strength At 168 hrs ± 2 hr - IS 4031 Part 6) |
- |
|
|
|
| 7 Table-3 iv a (Compressive Strength At 72 hrs ± 1 hr - IS 4031 Part 6) |
- |
|
|
|
| 7 Table-3 iii b (Setting Time Final) |
- |
|
|
|
| 7 Table-3 iii a (Setting Time Initial) |
- |
|
|
|
| 7 Table-3 ii b (Expansion by Autoclave) |
- |
|
|
|
| 7 Table-3 ii a (Expansion by Le Chatelier) |
- |
|
|
|
| 7 Table-3 i. (Fineness) |
- |
|
|
|
|
- |
- Excluding Table 2,Clause 6.1 ,sl. no.(viii) , alkali content; |
| 970 |
IS 710 (2010) |
Marine plywood - Specification (Second Revision) |
- |
Rs 11200/- View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 7.1 (WORKMANSHIP AND FINISH ) |
- |
|
|
|
| 7.2 (WORKMANSHIP AND FINISH ) |
- |
|
|
|
| 7.3 (WORKMANSHIP AND FINISH ) |
- |
|
|
|
| 7.5 (WORKMANSHIP AND FINISH ) |
- |
|
|
|
| 6.1 (DIMENSIONS) |
- |
|
|
|
| 6.2 (DIMENSIONS) |
- |
|
|
|
| 6.3 (DIMENSIONS) |
- |
|
|
|
| 9.1.1 (MOISTURE CONTENT) |
- |
|
|
|
| 9.1.2 , 9.1.2.1 (Glue Adhesion in Dry State) |
- |
|
|
|
| 9.1.2 , 9.1.2.2 (Glue Adhesion in Dry State) |
- |
|
|
|
| 9.1.3 , 9.1.3.1.1 (Water resistance test) |
- |
|
|
|
| 9.1.3 , 9.1.3.1.2 (Water resistance test) |
- |
|
|
|
| 9.1.5 (Mycological test) |
- |
|
|
|
| 9.1.4 (Tensile strength) |
- |
|
|
|
| 9.1.6 (Table 3) (Static bending strength) |
- |
|
|
|
| 9.1.6 (Table 3) (Static bending strength) |
- |
|
|
|
| 9.1.7 (Table 4) (Wet bending strength) |
- |
|
|
|
| 9.1.7 (Table 4) (Wet bending strength) |
- |
|
|
|
| 9.1.8 (Retention of preservative) |
- |
|
|
|
| 11.1 (MARKING) |
- |
|
|
|
|
- |
- - |
| 971 |
IS 12786 (1989) |
Irrigation equipment - Polyethylene pipes for irrigation laterals - Specification |
- |
Please see remarks View breakup
Rs. 7800.00 (Excluding Testing Charges for Material Test) Rs. 3600.00 (Testing Charges for Material Test)
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 7.3 (Tensile Test) |
- |
|
|
|
| 7.3 (Elongation at Break) |
- |
|
|
|
| 4.1.c & 4.2.a (Carbon Black content - IS 2530 : 1963) |
- |
|
|
|
|
- |
- Excluding Environmental strees cracking resistance test and Cl 7.1 & Table 2 Hydraulic test; |
| 972 |
IS 14151 : Part 2 (2008) |
Irrigation equipment - Sprinkler pipes - Specification: Part 2 quick coupled polyethylene pipes and fittings (Second Revision) |
- |
- View breakup
Rs. 4250/-(Excluding leakage test and Hyd. Proof Test)+Testing charges as per IS 14151(Part 1)
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 7.2.1 (Visual and Workmanship Requirement) |
- |
|
|
|
| 4.2.7 (1 Dimensions of Quick Coupled Pipes and Fittings) |
- |
|
|
|
|
- |
- - |
| 973 |
IS 1489 (Part 1) (2015) |
Portland pozzolana cement - Specification: Part 1 fly Ash Based |
- |
- View breakup
Rs.8420/-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 6 - Table - 1 v (Chloride content - Cl 4.13 of IS 4032:1985) |
- |
|
|
|
| 6 - Table - 1 iv (Loss on ignition - Cl 7.1 of IS 4032:1985) |
- |
|
|
|
| 6 - Table - 1 i (Insoluble residue - Cl 7.4 of IS 4032:1985) |
- |
|
|
|
| 6 - Table - 1 iii (Total Sulphur Content calculated as Sulphuric Anhydride (SO3) - Cl 7.3 of IS 4032:1985) |
- |
|
|
|
| 6 - Table - 1 ii (Magnesia - Cl 7.2 of IS 4032:1985) |
- |
|
|
|
| 6 - Table - 1 vi ( Alkali content as (Na2O + 0.658 K2O) - Cl 4.11 of IS 4032:1985) |
- |
|
|
|
| 7 -Table 2- vi (Drying Shrinkage- IS 4031 Part 10) |
- |
|
|
|
| 7 -Table 2- iv- c (Compressive Strength At 672 hrs ± 4 hr - IS 4031 Part 6) |
- |
|
|
|
| 7 -Table 2- iv- b (Compressive Strength At 168 hrs ± 2 hr - IS 4031 Part 6) |
- |
|
|
|
| 7 -Table 2- iv- a (Compressive Strength At 72 hrs ± 1 hr - IS 4031 Part 6) |
- |
|
|
|
| 7 -Table 2-iii- b (Setting Time Final- 4031 Part 5) |
- |
|
|
|
| 7 -Table 2- iii- a (Setting Time Initial- 4031 Part 5) |
- |
|
|
|
| 7 -Table 2- ii- b (Expansion by Autoclave- 4031 Part 3) |
- |
|
|
|
| 7 -Table 2- ii- a (Expansion by Le Chatelier- 4031 Part 3) |
- |
|
|
|
| 7 -Table 2- i (Fineness 4031 Part 2) |
- |
|
|
|
|
- |
- Excluding Table 1,Clause 6 ,sl. no.(vi) , alkali content; |
| 974 |
IS 4985 (2021) |
UNPLASTICIZED PVC PIPES FOR POTABLE WATER SUPPLIES SPECIFICATION Fourth Revision |
- |
- View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 10.1 (Colour) |
- |
|
|
|
| 10.7 (Sulphated Ash Content) |
- |
|
|
|
| 10.1 (Colour) |
- |
|
|
|
| 10.7 (Sulphated Ash Content) |
- |
|
|
|
|
- |
- Excluding Effect on water |
| 975 |
IS 4984 (2016) |
Polyethylene pipes for water supply - Specification (Fifth Revision) |
- |
- View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl. 8.3 (Carbon Black Content) |
- |
|
|
|
| Cl-7.4 (Mean Outside Diameter (For upto 50 mm take 8 reading, above 50mm take 6 reading & average will be reported)) |
- |
|
|
|
| 8.2 (Longitudinal Reversion Test) |
- |
|
|
|
| Cl 8.3 (Carbon Black Dispersion) |
- |
|
|
|
| 8.7 (Density) |
- |
|
|
|
| 8.4 ( Melt Flow Rate) |
- |
|
|
|
| 7.4.1.2 (Ovality) |
- |
|
|
|
| 7.2 (Length) |
- |
|
|
|
| 6.2 (Colour) |
- |
|
|
|
| 6.2.1 (6.1.1 Identification Stripes) |
- |
|
|
|
|
- |
- Excluding Oxidation induction , overall migration, Cl 8.7 density, Cl 7.4.1.2 ovality Cl 8.8 Tensile,Cl 8.9 Elongation at Break; |
| 976 |
IS 2202 : Part 1 (2023) |
WOODEN FLUSH DOOR SHUTTERS SOLID CORE TYPE SPECIFICATION PART 1 PLYWOOD FACE PANELS Seventh Revision |
- |
- View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 9.1 (Workmanship & Finish) |
- |
|
|
|
| 9.2 (Workmanship & Finish) |
- |
|
|
|
| 9.3 (Workmanship & Finish) |
- |
|
|
|
| 11.1 (Dimensions - Height) |
- |
|
|
|
| 11.1 (Dimensions - Width) |
- |
|
|
|
| 9.3 (Workmanship & Finish) |
- |
|
|
|
| 11.1 (Dimensions - Thickness) |
- |
|
|
|
| 11.1 (Dimensions - Variation in thickness) |
- |
|
|
|
| 11.1 (Dimensions - Thickness) |
- |
|
|
|
| 11.1 (Dimensions - Width) |
- |
|
|
|
| 11.1 (Dimensions - Height) |
- |
|
|
|
| 9.1 (Workmanship & Finish) |
- |
|
|
|
| 9.2 (Workmanship & Finish) |
- |
|
|
|
| 9.3 (Workmanship & Finish) |
- |
|
|
|
| 11.14 (Glue Adhesion Test) |
- |
|
|
|
| 11.13 (Knife Test) |
- |
|
|
|
| 11.12 (End immersion test) |
- |
|
|
|
| Clause 11.11 (Varying Humidity Test) |
- |
|
|
|
| 11.10 (Misuse Test) |
- |
|
|
|
| 11.9.2 (Slamming Test) |
- |
|
|
|
| 11.8 (Buckling Test) |
- |
|
|
|
| Clause 11.7 (Shock Resistance Test) |
- |
|
|
|
| 11.4 (Impact Indentation Test) |
- |
|
|
|
| Clause 11.2 (General Flatness Test) |
- |
|
|
|
| 11.1 (Dimensions - Squareness) |
- |
|
|
|
| 11.1 (Dimensions - Height) |
- |
|
|
|
| 11.1 (Dimensions - Width) |
- |
|
|
|
|
- |
- Excluding Test facility not available for Cl 11.2, 11.4, 11.6, 11.8, 11.9; |
| 977 |
IS 2830 (2012) |
Carbon steel cast billet ingots, billets, blooms and slabs for re-rolling into steel for general structural purposes - Specification (Third Revision) |
- |
Rs. 5250/- View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl 9 (Workmanship) |
- |
|
|
|
| Cl 10.2 (Workmanship) |
- |
|
|
|
| Cl 10.3 (Workmanship) |
- |
|
|
|
| Cl 11 (Length, Width & Thickness) |
- |
|
|
|
| 6.1 (Carbon %) |
- |
|
|
|
| 6.1 (Sulphur %) |
- |
|
|
|
| 6.1 (Phosphorus %) |
- |
|
|
|
| 6.1 (Silicon %) |
- |
|
|
|
| 6.1 ( Aluminium %) |
- |
|
|
|
| 6.1 ( Nitrogen%) |
- |
|
|
|
| 6 (Sulphur + Phosphorus) |
- |
|
|
|
| 6.1 ( Nb) |
- |
|
|
|
| 6.1 (V) |
- |
|
|
|
| 6.1 ( Ti) |
- |
|
|
|
| 6 (carbon equivalent (CE)) |
- |
|
|
|
| 6 (Copper as Cu) |
- |
|
|
|
| Clause 6, Table 1 Note : 3 (Nb+V+Ti) |
- |
|
|
|
| 6.1 (Cr) |
- |
|
|
|
| 6.1 (Mo) |
- |
|
|
|
| 6.1 (Ni) |
- |
|
|
|
| Cl 6.1 (Manganese) |
- |
|
|
|
|
- |
- - |
| 978 |
IS 1659 (2004) |
Block boards - Specification (Fourth Revision) |
- |
Rs.6494.00 View breakup
Rs 5900/- for BWR Grade, Rs.6800/- for MR grade
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 9.2.6 (Spot test - Annexure L) |
- |
|
|
|
| 9.2.5 (Modulus of elasticity - MINIMUM INDIVIDUAL - Annexure K) |
- |
|
|
|
| 9.2.5 (Modulus of elasticity - AVERAGE - Annexure K) |
- |
|
|
|
| 9.2.5 (Modulus of rupture - MINIMUM INDIVIDUAL - Annexure K) |
- |
|
|
|
| 9.2.5 (Modulus of rupture - AVERAGE - Annexure K) |
- |
|
|
|
| 9.2.4 (Mycological Test [for MR grade only] - Annexure J) |
- |
|
|
|
| 9.2.3 (Adhesion of Plies - Annexure H) |
- |
|
|
|
| 9.2.2 (Resistance to water - Annexure G, Annexure H [For MR Grade]) |
- |
|
|
|
| 9.2.2 (Resistance to water - Annexure G, Annexure H [For BWP grade]) |
- |
|
|
|
| 9.2.1 (Dimensional Changes caused by humidity Change in local planeness - Annexure F) |
- |
|
|
|
| 9.2.1 (Dimensional Changes caused by humidity - Delamination - Annexure F) |
- |
|
|
|
| 9.2.1 (Dimensional Changes caused by humidity - Change in thickness - at 40% RH - Annexure F) |
- |
|
|
|
| 9.2.1 (Dimensional Changes caused by humidity - Change in Thickness - at 90% RH - Annexure F) |
- |
|
|
|
| 9.2.1 (Dimensional Changes caused by humidity - Change in Length - at 40% RH - Annexure F) |
- |
|
|
|
| 9.2.1 (Dimensional Changes caused by humidity - Change in Length - at 90% RH - Annexure F) |
- |
|
|
|
| 7.3 (Dimensional Requirements - Variation in thickness - Annexure E) |
- |
|
|
|
| 7.3 (Dimensional Requirements - Squareness - Annexure D) |
- |
|
|
|
| 7.3 (Dimensional Requirements - Edge Straightness - Annexure D) |
- |
|
|
|
| 7.3 (Dimensional Requirements - Thickness - Annexure E) |
- |
|
|
|
| 7.3 (Dimensional Requirements - Width - 8.1.4) |
- |
|
|
|
| 7.3 (Dimensional Requirements - Length - 8.1.4) |
- |
|
|
|
| 8.1.3, 6.3.3, IS 1328 (Visual Inspection - Permissible Defects - IS 1328 [test method for DECORATIVE type]) |
- |
|
|
|
| 8.1.3, 6.3.3, IS 303 (Visual Inspection - Permissible Defects - IS 303 [test method for COMMERCIAL type]) |
- |
|
|
|
| 9.2.6 (mechanical) (Spot test - Annexure L) |
- |
|
|
|
|
- |
- SIZE: One Block Board
Sample Size without dimensional measurements:Length-1200 mm, width-1200 |
| 979 |
IS 13334 : Part 1 (2014) |
Skimmed milk powder - Specification: Part 1 standard grade (Second Revision) |
- |
Rs 24306 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 5.6 (Bacterial count) |
- |
|
|
|
| 5.6 (Coliform count ) |
- |
|
|
|
| 5.6 (Escherichia coli) |
- |
|
|
|
| 5.6 (Coagulase positive Staphylococcus aureus) |
- |
|
|
|
| 5.6 (Salmonella) |
- |
|
|
|
| 5.6 (Spore count, Aerobic (Bacillus cereus)) |
- |
|
|
|
| 5.6 (Spore count, Anaerobic (Sulfite reducing Clostridia)) |
- |
|
|
|
| 5.6 (Listeria monocytogenes) |
- |
|
|
|
| 4 (Description) |
- |
|
|
|
| Cl 5.1 (Milk intended (IS 1479 - Part 1)) |
- |
|
|
|
| 5.2 (Absence of extraneous matter, added colour and added flavour) |
- |
|
|
|
| Cl 5.3 (Calcium chloride,
citric acid and sodium citrate, sodium salts of
orthophosphoric acid and polyphosphoric acid (as
linear phosphate), ) |
- |
|
|
|
| Cl 5.4 (The flavour of the product or of the reconstituted
milk shall be pleasant and clean (see IS 10030).) |
- |
|
|
|
| 5.6 (Moisture) |
- |
|
|
|
| 5.6 (Milk protein in milk solids not fat) |
- |
|
|
|
| 5.6 (Milk fat) |
- |
|
|
|
| 5.6 (Insolubility index) |
- |
|
|
|
| 5.6 (Milk fat) |
- |
|
|
|
| 5.6 (Titratable acidity (lactic acid)) |
- |
|
|
|
| 5.6 (Scorched particles) |
- |
|
|
|
| 5.6 (Total ash (on dry basis)) |
- |
|
|
|
| 5.6 (Coliform count ) |
- |
|
|
|
| 5.6 (Salmonella) |
- |
|
|
|
| 5.6 (Bacterial count) |
- |
|
|
|
|
- |
- 500 gm x 3 |
| 980 |
IS 303 (2024) |
Plywood for General Purposes â Specification (Fourth Revision) |
- |
Rs 4000/- /BWR Grade, Rs.4900/- for MR Grade View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl-5.1 (Classification by appearance) |
- |
|
|
|
| Cl-11.6 (Formaldehyde Content Test) |
- |
|
|
|
|
- |
- Facility not available: Static bending strength above 15 mm thickness. ;
Excluding- Steady State Formaldehyde Emission Test (Cl. 11.7) |