121 |
IS 3104 : Part 1 (1982) |
Specification for density hydrometers: Part 1 requirements (First Revision) |
- |
-
|
- View breakup
Rs. 4800/- excluding accuracy test
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
Cl.11.2 ( Stem diameter of the hydrometers shall be not less than 40 mm.) |
- |
|
|
|
Cl.10.1 workmanshisp and finish ( The outer surface of the hydrometers shall be symmetrical about the main axis) |
- |
|
|
|
Cl.10.2 ( There shall be no abrupt changes in their cross section ( see Fig, 1 )) |
- |
|
|
|
Cl.10.3 ( The cross-section of the stem shall remain unchanged for at least
5 mm below the lowest graduation line on ??? scale.) |
- |
|
|
|
Cl.10.4 (The stem shall extend unchanged in diameter at least 15 mm above
the uppermost graduation line on the scale.) |
- |
|
|
|
Cl.10.5 ( The hydrometer shall float with its axis vertical to within 1.5° of
arc.) |
- |
|
|
|
Cl.10.6 (There shall be no loose material in the instrument) |
- |
|
|
|
Cl.10.7 ( The strip on which the scale and inscriptions are marked shall
remain securely fastened in place at the temperature of use ( see 9.3 ).) |
- |
|
|
|
Cl.10.8 ( The scale shall be straight and without twist.) |
- |
|
|
|
Cl.10.9 ( Appropriate means shall be incorporated for ensuring that any
displacement of the scale or of the strip bearing the scale is readily
apparent.) |
- |
|
|
|
Cl.11.1 ( The dimensions of the hydrometers shall conform to the requirements
given in Table 1.) |
- |
|
|
|
Cl.12.2
Cl.12.2.1
Graduation Lines ( The graduation lines shall be distinct and of uniform thickness
not exceeding 0 2 mm or one-fifth of the distance between the centres of
adjacent lines, whichever is less. For the SP series, the thickness of the
graduation lines shall not exceed 0.2 mm or one-sixth of the distance
between the centres of adjacent lines, whichever is less.) |
- |
|
|
|
Cl.12.2.2 (There shall be no evident local irregularities in the spacing of
the graduation lines.) |
- |
|
|
|
Cl.12.2.3 ( The graduation lines shall be perpendicular to the axis of the
hydrometer.) |
- |
|
|
|
Cl.12.2.4 (The short, medium and long scale lines shall extend, respectively,
at least one-fifth, one-third and one-half of the way round the
circumference of the stem.) |
- |
|
|
|
Cl.12.2.5 ( The highest and lowest graduation lines indicating the nominal
limits of the scale shall be long lines ( see 12.3.1, 12.3.2 and 12.3.3 ).) |
- |
|
|
|
Cl.12.5 Extension of Scale ( — The scale shall be extended beyond the nominal scale limits, as indicated in col 12 of Table 1.) |
- |
|
|
|
|
Partial
|
|
- |
Excluding Accuracy test |
122 |
IS 5852 (2004) |
Protective Steel Toe Caps for Footwear |
- |
-
|
Rs 2400/- View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
5/5.1- Fig. 1 and Fig. 2, Table 1. (REQUIREMENTS-Shape and Dimension) |
- |
|
|
|
5/5.3 (REQUIREMENTS-Finish) |
- |
|
|
|
5/5.1- Fig. 1 and Fig. 2, Table 1. (REQUIREMENTS-Shape and Dimension) |
- |
|
|
|
5/5.3 (REQUIREMENTS-Finish) |
- |
|
|
|
5/5.1- Fig. 1 and Fig. 2, Table 1. (REQUIREMENTS-Shape and Dimension) |
- |
|
|
|
5/5.3 (REQUIREMENTS-Finish) |
- |
|
|
|
|
Partial
|
|
- |
Test facility not available NRL |
123 |
IS 14433 (2007) |
Infant milk substitutes - Specification (First Revision) |
- |
-
|
- View breakup
Rs. 29610/- excl. Vitamin-E, Linoleate content, Vitamin-A(as retinol), added Vitamin-D (expressed as Cholecalciferol), Thimine, Niacin, Riboflavin, Vitamin-B6, Vitamin-B12, Folic
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
6.1 (Moisture) |
- |
|
|
|
6.1 (Milk protein) |
- |
|
|
|
6.1 (Milk fat) |
- |
|
|
|
6.1 (Total ash) |
- |
|
|
|
6.1 (Acid insoluble ash) |
- |
|
|
|
6.1 (Insolubility index) |
- |
|
|
|
6.4 (Scorched particles) |
- |
|
|
|
|
Partial
|
|
- |
Microbiological testing is complete, Partial for Chemical Excluding Vitamins, Heavy Metals |
124 |
IS 9968 : Part 1 (1988) |
Specification for elastomer insulatedcables: Part 1 for working voltages up to and including 1100 volts (First Revision) |
- |
-
|
Rs.12000/ View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
3.1 ( Copper Cooduetor) |
- |
|
|
|
3.2 (Aluminium conductor) |
- |
|
|
|
4.1 (INSULATION : lnsulation for General Service) |
- |
|
|
|
4.2 (INSULATION : Heat Resisting insulation) |
- |
|
|
|
4.3 (INSULATION : Silicone Rubber Insulation) |
- |
|
|
|
5.1 (TAPE : Proofed Tape) |
- |
|
|
|
5.2 (TAPE : 2 Polyethyl_ Terephthalate ( PETP ) Tape or
Plastic: Tape or Any Other SlIIitable Tape ) |
- |
|
|
|
5.3 (TAPE : Giass Tape) |
- |
|
|
|
6.1 (FILLERS : ) |
- |
|
|
|
7.1 (BRAID : Textile Braid) |
- |
|
|
|
7.2 (BRAID : Glass Braid ) |
- |
|
|
|
8.1 (SHEATH : General Service Insulated Cables and Flexible
Cords) |
- |
|
|
|
8.2 (SHEATH :Heat Resisting Insulated Cables) |
- |
|
|
|
9.1 (PresenRtive Compound) |
- |
|
|
|
9.2 (Varnish) |
- |
|
|
|
10 ( Conductor ) |
- |
|
|
|
11 (Separator tape) |
- |
|
|
|
12.2 (Insulation : Thickness of Insufatien) |
- |
|
|
|
12.4 (Insulation : Allplication of Insulation) |
- |
|
|
|
13 (CORE IDENTiFICATlON) |
- |
|
|
|
14 (Tape) |
- |
|
|
|
15 (BRAIDING) |
- |
|
|
|
16 (COMPOUNDING AND VARNISHING) |
- |
|
|
|
17 (LAYING UP OF CORES) |
- |
|
|
|
18 ( Binder tape) |
- |
|
|
|
19.2 (Sheath : Thickness of Sheath) |
- |
|
|
|
19.4 ( Sheath :Colour) |
- |
|
|
|
20 ( Overall diameter) |
- |
|
|
|
21. (b) (Annealing Test (for coper)) |
- |
|
|
|
21. (c) ( Tensile Test (for aluminium)) |
- |
|
|
|
21. (d) ( Wrapping Test (for aluminium)) |
- |
|
|
|
21. (e) (Conductor Resistance ) |
- |
|
|
|
21.1 ( Tensile strength ) |
- |
|
|
|
22.1 ( Elongation) |
- |
|
|
|
21.1 (type test : Ageing In air oven) |
- |
|
|
|
21.1 (type test : Ageing in air bomb) |
- |
|
|
|
21.1 (type test : Ageing In oxygen
bomb) |
- |
|
|
|
21.1 (type test : Tear resistance ) |
- |
|
|
|
22.2 (type test :Insulauon resistance High voltage (water immersron ) test) |
- |
|
|
|
22.2 (type test : Flammability test
( applicable to cables
finished With SE 3 and
SE 4 sheaths only)
) |
- |
|
|
|
21 (Water absorption test) |
- |
|
|
|
23 (identification) |
- |
|
|
|
|
Partial
|
|
- |
Excluding Cl.21.1 water absorption test (electrical) for IE2 |
125 |
IS 5950 (1984) |
Specification for shot firing cables (For Use Other Than In Shafts) (First Revision) |
- |
-
|
- View breakup
Rs 11030/-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
3.1 (Conductor : Material -IS : 8130-2013) |
- |
|
|
|
4.1 (Insulation : Material -IS : 5831-1984) |
- |
|
|
|
5.1 (Sheath : materail IS : 5831-1984) |
- |
|
|
|
6.1 (Conductor : Construction IS : 8130-2013) |
- |
|
|
|
7.1 (Insulation : Application ) |
- |
|
|
|
7.2 (Thickness of Insulation - average ) |
- |
|
|
|
7.2 (Thickness of Insulation - Min. ) |
- |
|
|
|
7.3 (Colour of Insulation) |
- |
|
|
|
8.1, 9.1 (c) (Nominal radial thickness of sheath) |
- |
|
|
|
8.2 (Thickness of Sheath) |
- |
|
|
|
8.2 (Thickness of Sheath - min.) |
- |
|
|
|
8.3 (Colour of Sheath) |
- |
|
|
|
9.1 a) (Annealing test) |
- |
|
|
|
9.1 b) (Conductor resistance test) |
- |
|
|
|
9.1 d) i) (Insulation : Tensile strength) |
- |
|
|
|
9.1 d) i) (Insulation : elongation at break) |
- |
|
|
|
9.1 d) i) (Sheath : Tensile strength) |
- |
|
|
|
9.1 d) i) (Sheath : elongation at break) |
- |
|
|
|
9.1 d) ii) (Ageing in air oven - Insulation : Tensile strength) |
- |
|
|
|
9.1 d) ii) (Ageing in air oven - Insulation : Tensile strength Variation) |
- |
|
|
|
9.1 d) ii) (Ageing in air oven - Insulation : elongation at break) |
- |
|
|
|
9.1 d) ii) (Ageing in air oven - Insulation : elongation variation at break) |
- |
|
|
|
9.1 d) ii) (Ageing in air oven - Sheath : Tensile strength) |
- |
|
|
|
9.1 d) ii) (Ageing in air oven - Sheath : Tensile strength variation ) |
- |
|
|
|
9.1 d) ii) (Ageing in air oven - Sheath : elongation at break) |
- |
|
|
|
9.1 d) ii) (Ageing in air oven - Sheath : elongation variation at break) |
- |
|
|
|
9.1 d) iii ) (Loss of mass test - insulation ) |
- |
|
|
|
9.1 d) iii ) (Loss of mass test - Sheath ) |
- |
|
|
|
9.1 d) iv ) (Hot deformation - insulation ) |
- |
|
|
|
9.1 d) iv ) (Hot deformation - sheath ) |
- |
|
|
|
9.1 d) v ) (Heat shock - insulation ) |
- |
|
|
|
9.1 d) v ) (Heat shock - Sheath ) |
- |
|
|
|
9.1 d) vi ) (Shrinkage - insulation ) |
- |
|
|
|
9.1 d) vi ) (Shrinkage : Crack observed - insulation ) |
- |
|
|
|
9.1 d) vi ) (Shrinkage - Sheath ) |
- |
|
|
|
9.1 d) vi ) (Shrinkage: Crack observed - Sheath ) |
- |
|
|
|
9.1 f) (Insulation resistance test: Volume resistivity ) |
- |
|
|
|
9.1 f) (Insulation resistance test : IR constant) |
- |
|
|
|
10.4 (Flammability Test ) |
- |
|
|
|
11.1 (Manufacturer’s Identification) |
- |
|
|
|
11.2 (Cable Code) |
- |
|
|
|
12.1 (packing ) |
- |
|
|
|
12.2 (Marking ) |
- |
|
|
|
12.2.1 (Standard marks ) |
- |
|
|
|
|
Partial
|
|
- |
- |
126 |
IS 2465 (1984) |
Specification for cables for motor vehicles (Second Revision) |
- |
-
|
Single core PVC Insulated Unsheathed: Rs. 11030/- View breakup
Single core PVC Insulated Unsheathed: Rs. 11030/- Single core PVC Insulated Sheathed: 75 % additional for sheath. Multi core with PVC Sheath: 75% additional for each additional core. Round and flat tinned copper braids without further covering for earthing: Rs. 1115/- Above charges are excluding Material tests, Ageing in oxygen bomb, Capacitance test, Ozone resistance test, Effect of heat on flexibility, Effect of oils, Effect of lubricating oil, brake fluid, diesel and petrol, Effect of cooling on flexibility.
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
7.1 (Insulation) |
- |
|
|
|
7.3 (Insulation) |
- |
|
|
|
8 (Core Identification) |
- |
|
|
|
9 (Laying up of cores) |
- |
|
|
|
10.1.1 (Sheathing ) |
- |
|
|
|
10.2 (Sheathing ) |
- |
|
|
|
3 & 6 (Flexibility class) |
- |
|
|
|
3 & 6 (Construction) |
- |
|
|
|
3 & 6 (Diameter of wire(mm)) |
- |
|
|
|
3 & 6 (Annealing test) |
- |
|
|
|
3 & 6 (Persulphate Test) |
- |
|
|
|
3 & 6 (Conductor resistance Test (ohm/km at 20˚c)) |
- |
|
|
|
7.2, 10.3, 11 (Dimensions & thickness ) |
- |
|
|
|
7.2, 10.3, 11 (Dimensions & thickness ) |
- |
|
|
|
7.2, 10.3, 11 (Overall Dimension (mm)) |
- |
|
|
|
4.2 & 12.1 (Without Ageing For Insulation
Tensile Strength (N/mm²)) |
- |
|
|
|
4.2 & 12.1, (f), 1 (elongation at break (N/mm²)) |
- |
|
|
|
4.2 & 12.1, (f), 1 (Tensile Strength at break (N/mm²)) |
- |
|
|
|
4.2 & 12.1, (e), 1 (elongation test at break) |
- |
|
|
|
4.2 & 12.1, (e), 1 (Tensile strength at break) |
- |
|
|
|
4.2 & 12.1, (f), 2 (Ageing in air oven) |
- |
|
|
|
4.2 & 12.1, (f), 3 (Ageing in oxygen bomb) |
- |
|
|
|
4.2 & 12.1, (e), 2 (After Ageing in air oven) |
- |
|
|
|
4.2 & 12.1, (e), 3 (Loss of mass test (mg/cm²) of Insulation) |
- |
|
|
|
4.2 & 12.1, (e), 3 (Loss of mass test (mg/cm²) of Sheath) |
- |
|
|
|
4.2 & 12.1, (e), 4 (Hot deformation test (%) of Insulation) |
- |
|
|
|
4.2 & 12.1, (e), 4 (Hot deformation test (%) of Sheath) |
- |
|
|
|
4.2 & 12.1, (e), 5 (Heat Shock Test of Insulation) |
- |
|
|
|
4.2 & 12.1, (e), 5 (Heat Shock Test of Sheath) |
- |
|
|
|
4.2 & 12.1, (e), 6 (Shrinkage Test (%) of Insulation) |
- |
|
|
|
4.2 & 12.1, (e), 6 (Shrinkage Test (%) of Sheath) |
- |
|
|
|
14 (High Voltage Test) |
- |
|
|
|
22.1 (FLAMMABILITY TEST) |
- |
|
|
|
22.1 (FLAMMABILITY TEST) |
- |
|
|
|
23.1 (Manufacturer's Identification) |
- |
|
|
|
23.1 (Manufacturer's Identification) |
- |
|
|
|
24.1 (PACKING AND MARKING) |
- |
|
|
|
24.2 (PACKING AND MARKING) |
- |
|
|
|
24.2.1 (PACKING AND MARKING) |
- |
|
|
|
|
Partial
|
|
- |
"Complete for general wiring only & Partial for PVC Insulation ignition cable
Excluding Cl. 16 capacitance, Cl. 18 Effect of heat on flexibility" |
127 |
IS 4159 (2002) |
Mineral filled sheathed heating elements - Specification (Third Revision) |
- |
-
|
Rs.10500/- View breakup
for 1 to 3 kW Excluding leakage and Hydrostatic Strength Test (for immersion oil heating elements)
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
Cl.6 of IS 4159:2002 &
IS 302-1:2008
(Classification) |
- |
|
|
|
Cl.6 of IS 4159:2002 &
IS 302-1:2008
(Classification) |
- |
|
|
|
Cl.7 of IS 4159:2002 & IS 302-1:2008 (Marking
) |
- |
|
|
|
Cl.7 of IS 4159:2002 & IS 302-1:2008 (Marking
) |
- |
|
|
|
Cl.7 of IS 4159:2002 & IS 302-1:2008 (Marking
) |
- |
|
|
|
Cl.7 of IS 4159:2002 & IS 302-1:2008 (Marking
) |
- |
|
|
|
Cl.7 of IS 4159:2002 & IS 302-1:2008 (Marking
) |
- |
|
|
|
Cl.7 of IS 4159:2002 & IS 302-1:2008 (Marking
) |
- |
|
|
|
Cl.7 of IS 4159:2002 & IS 302-1:2008 (Marking
) |
- |
|
|
|
Cl.7 of IS 4159:2002 & IS 302-1:2008 (Marking
) |
- |
|
|
|
Cl.7 of IS 4159:2002 & IS 302-1:2008 (Marking
) |
- |
|
|
|
Cl.7 of IS 4159:2002 & IS 302-1:2008 (Marking
) |
- |
|
|
|
Cl.7 of IS 4159:2002 & IS 302-1:2008 (Marking
) |
- |
|
|
|
Cl.7 of IS 4159:2002 & IS 302-1:2008 (Marking
) |
- |
|
|
|
Cl.7 of IS 4159:2002 & IS 302-1:2008 (Marking
) |
- |
|
|
|
Cl.8 of IS 4159:2002 & IS 302‐1:2008 (Protection Against Electric Shock) |
- |
|
|
|
Cl.10 of IS 4159:2002 &
IS 302-1:2008 (Input & Current) |
- |
|
|
|
Cl.11 of IS 4159:2002 & IS 302‐1:2008 (Temperature Rise) |
- |
|
|
|
Cl.11 of IS 4159:2002 & IS 302‐1:2008 (Temperature Rise) |
- |
|
|
|
Cl.11 of IS 4159:2002 & IS 302‐1:2008 (Temperature Rise) |
- |
|
|
|
Cl.11 of IS 4159:2002 & IS 302‐1:2008 (Temperature Rise) |
- |
|
|
|
Cl.11 of IS 4159:2002 & IS 302‐1:2008 (Temperature Rise) |
- |
|
|
|
Cl.11 of IS 4159:2002 & IS 302‐1:2008 (Temperature Rise) |
- |
|
|
|
Cl.11 of IS 4159:2002 & IS 302‐1:2008 (Temperature Rise) |
- |
|
|
|
Cl.11 of IS 4159:2002 & IS 302‐1:2008 (Temperature Rise) |
- |
|
|
|
Cl.11 of IS 4159:2002 & IS 302‐1:2008 (Temperature Rise) |
- |
|
|
|
Cl.13 of IS 4159:2002 & IS 302-1: 2008 (Electrical Insulation and Leakage Current at Operating Temperature) |
- |
|
|
|
Cl.13 of IS 4159:2002 & IS 302-1: 2008 (Electrical Insulation and Leakage Current at Operating Temperature) |
- |
|
|
|
Cl.15 of IS 4159:2002 & IS 302-1: 2008 (Moisture Resistance) |
- |
|
|
|
Cl.15 of IS 4159:2002 & IS 302-1: 2008 (Moisture Resistance) |
- |
|
|
|
Cl.15 of IS 4159:2002 & IS 302-1: 2008 (Moisture Resistance) |
- |
|
|
|
Cl.16 of IS 4159:2002 & IS 302-1: 2008 (Insulation Resistance & Electric Strength (after Humidity Treatment)) |
- |
|
|
|
Cl.16 of IS 4159:2002 & IS 302-1: 2008 (Insulation Resistance & Electric Strength (after Humidity Treatment)) |
- |
|
|
|
Cl.18 of IS 4159:2002 (Endurance Test
) |
- |
|
|
|
Cl.19 of IS 4159:2002 & IS 302-1: 2008 (Abnormal Operation) |
- |
|
|
|
Cl.19 of IS 4159:2002 & IS 302-1: 2008 (Abnormal Operation) |
- |
|
|
|
Cl.19 of IS 4159:2002 & IS 302-1: 2008 (Abnormal Operation) |
- |
|
|
|
Cl.19 of IS 4159:2002 & IS 302-1: 2008 (Abnormal Operation) |
- |
|
|
|
Cl.19 of IS 4159:2002 & IS 302-1: 2008 (Abnormal Operation) |
- |
|
|
|
Cl.19 of IS 4159:2002 & IS 302-1: 2008 (Abnormal Operation) |
- |
|
|
|
Cl.19 of IS 4159:2002 & IS 302-1: 2008 (Abnormal Operation) |
- |
|
|
|
Cl.19 of IS 4159:2002 & IS 302-1: 2008 (Abnormal Operation) |
- |
|
|
|
Cl.19 of IS 4159:2002 & IS 302-1: 2008 (Abnormal Operation) |
- |
|
|
|
Cl.19 of IS 4159:2002 & IS 302-1: 2008 (Abnormal Operation) |
- |
|
|
|
Cl.19 of IS 4159:2002 & IS 302-1: 2008 (Abnormal Operation) |
- |
|
|
|
Cl.19 of IS 4159:2002 & IS 302-1: 2008 (Abnormal Operation) |
- |
|
|
|
Cl.19 of IS 4159:2002 & IS 302-1: 2008 (Abnormal Operation) |
- |
|
|
|
Cl.19 of IS 4159:2002 & IS 302-1: 2008 (Abnormal Operation) |
- |
|
|
|
Cl.19 of IS 4159:2002 & IS 302-1: 2008 (Abnormal Operation) |
- |
|
|
|
Cl.20 of IS 4159:2002 & IS 302-1: 2008 (Stability & Mechanical Hazards
) |
- |
|
|
|
Cl.21 of IS 4159:2002 & IS 302-1: 2008 (Mechanical Strength) |
- |
|
|
|
Cl.21 of IS 4159:2002 & IS 302-1: 2008 (Mechanical Strength) |
- |
|
|
|
Cl.22 of IS 4159:2002 &
IS 302-1: 2008 (Construction) |
- |
|
|
|
Cl.22 of IS 4159:2002 &
IS 302-1: 2008 (Construction) |
- |
|
|
|
Cl.22 of IS 4159:2002 &
IS 302-1: 2008 (Construction) |
- |
|
|
|
Cl.22 of IS 4159:2002 &
IS 302-1: 2008 (Construction) |
- |
|
|
|
Cl.22 of IS 4159:2002 &
IS 302-1: 2008 (Construction) |
- |
|
|
|
Cl.19 of IS 4159:2002 & IS 302-1: 2008 (Abnormal Operation) |
- |
|
|
|
Cl.22 of IS 4159:2002 &
IS 302-1: 2008 (Construction) |
- |
|
|
|
Cl.22 of IS 4159:2002 &
IS 302-1: 2008 (Construction) |
- |
|
|
|
Cl.22 of IS 4159:2002 &
IS 302-1: 2008 (Construction) |
- |
|
|
|
Cl.22 of IS 4159:2002 &
IS 302-1: 2008 (Construction) |
- |
|
|
|
Cl.22 of IS 4159:2002 &
IS 302-1: 2008 (Construction) |
- |
|
|
|
Cl.22 of IS 4159:2002 &
IS 302-1: 2008 (Construction) |
- |
|
|
|
Cl.22 of IS 4159:2002 &
IS 302-1: 2008 (Construction) |
- |
|
|
|
Cl.22 of IS 4159:2002 &
IS 302-1: 2008 (Construction) |
- |
|
|
|
Cl.22 of IS 4159:2002 &
IS 302-1: 2008 (Construction) |
- |
|
|
|
Cl.22 of IS 4159:2002 &
IS 302-1: 2008 (Construction) |
- |
|
|
|
Cl.23 of IS 4159:2002 &
IS 302-1: 2008 (Internal Wiring
) |
- |
|
|
|
Cl.23 of IS 4159:2002 &
IS 302-1: 2008 (Internal Wiring
) |
- |
|
|
|
Cl.23 of IS 4159:2002 &
IS 302-1: 2008 (Internal Wiring
) |
- |
|
|
|
Cl.23 of IS 4159:2002 &
IS 302-1: 2008 (Internal Wiring
) |
- |
|
|
|
Cl.23 of IS 4159:2002 &
IS 302-1: 2008 (Internal Wiring
) |
- |
|
|
|
Cl.23 of IS 4159:2002 &
IS 302-1: 2008 (Internal Wiring
) |
- |
|
|
|
Cl.23 of IS 4159:2002 &
IS 302-1: 2008 (Internal Wiring
) |
- |
|
|
|
Cl.23 of IS 4159:2002 &
IS 302-1: 2008 (Internal Wiring
) |
- |
|
|
|
Cl.23 of IS 4159:2002 &
IS 302-1: 2008 (Internal Wiring
) |
- |
|
|
|
Cl.23 of IS 4159:2002 &
IS 302-1: 2008 (Internal Wiring
) |
- |
|
|
|
Cl.24 of IS 4159:2002 &
IS 302-1: 2008 (Component ) |
- |
|
|
|
Cl.24 of IS 4159:2002 &
IS 302-1: 2008 (Component ) |
- |
|
|
|
Cl.25 of IS 4159:2002 & IS 302-1: 2008 (Supply connection & external flexible cables & cords) |
- |
|
|
|
Cl.26 of IS 4159:2002 & IS 302-1: 2008 (Terminals for External Conductors) |
- |
|
|
|
Cl.26 of IS 4159:2002 & IS 302-1: 2008 (Terminals for External Conductors) |
- |
|
|
|
Cl.26 of IS 4159:2002 & IS 302-1: 2008 (Terminals for External Conductors) |
- |
|
|
|
Cl.26 of IS 4159:2002 & IS 302-1: 2008 (Terminals for External Conductors) |
- |
|
|
|
Cl.26 of IS 4159:2002 & IS 302-1: 2008 (Terminals for External Conductors) |
- |
|
|
|
Cl.26 of IS 4159:2002 & IS 302-1: 2008 (Terminals for External Conductors) |
- |
|
|
|
Cl.26 of IS 4159:2002 & IS 302-1: 2008 (Terminals for External Conductors) |
- |
|
|
|
Cl.26 of IS 4159:2002 & IS 302-1: 2008 (Terminals for External Conductors) |
- |
|
|
|
Cl.26 of IS 4159:2002 & IS 302-1: 2008 (Terminals for External Conductors) |
- |
|
|
|
Cl.26 of IS 4159:2002 & IS 302-1: 2008 (Terminals for External Conductors) |
- |
|
|
|
Cl.26 of IS 4159:2002 & IS 302-1: 2008 (Terminals for External Conductors) |
- |
|
|
|
Cl.26 of IS 4159:2002 & IS 302-1: 2008 (Terminals for External Conductors) |
- |
|
|
|
Cl.26 of IS 4159:2002 & IS 302-1: 2008 (Terminals for External Conductors) |
- |
|
|
|
Cl.27 of IS 4159:2002 & IS 302-1: 2008 (Provision for Earthing) |
- |
|
|
|
Cl.27 of IS 4159:2002 & IS 302-1: 2008 (Provision for Earthing) |
- |
|
|
|
Cl.27 of IS 4159:2002 & IS 302-1: 2008 (Provision for Earthing) |
- |
|
|
|
Cl.27 of IS 4159:2002 & IS 302-1: 2008 (Provision for Earthing) |
- |
|
|
|
Cl.27 of IS 4159:2002 & IS 302-1: 2008 (Provision for Earthing) |
- |
|
|
|
Cl.28 of IS 4159:2002 & IS 302-1: 2008 (Screws & Connection ) |
- |
|
|
|
Cl.28 of IS 4159:2002 & IS 302-1: 2008 (Screws & Connection ) |
- |
|
|
|
Cl.28 of IS 4159:2002 & IS 302-1: 2008 (Screws & Connection ) |
- |
|
|
|
Cl.28 of IS 4159:2002 & IS 302-1: 2008 (Screws & Connection ) |
- |
|
|
|
Cl. 29 of IS 4159:2002 &
IS 302-1: 2008 (Creepage Distances & Clearances) |
- |
|
|
|
Cl. 29 of IS 4159:2002 &
IS 302-1: 2008 (Creepage Distances & Clearances) |
- |
|
|
|
Cl. 30 of IS 4159:2002 &
IS 302-1: 2008 (Resistance to Heat, Fire and Tracking) |
- |
|
|
|
Cl. 30 of IS 4159:2002 &
IS 302-1: 2008 (Resistance to Heat, Fire and Tracking) |
- |
|
|
|
Cl. 31 of IS 4159:2002 &
IS 302-1: 2008 (Resistance to Rusting) |
- |
|
|
|
Cl. 33.1 of IS 4159:2002 (Finish Test
) |
- |
|
|
|
Cl. 29 of IS 4159:2002 &
IS 302-1: 2008 (Creepage Distances & Clearances) |
- |
|
|
|
|
Complete
|
|
- |
Standard is revised and test facilty details for latest version mentioned at Sr. no. 16 |
128 |
IS 8978 (1992) |
Specification for electric instantaneous water heaters (Second Revision) |
- |
-
|
Rs.15030/ View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
Cl.6 of IS 302-2-35:2017 (Classification) |
- |
|
|
|
Cl.6 of IS 302-2-35:2017 (Classification) |
- |
|
|
|
Cl.8 of IS 302-2-35:2017 (Protection Against Access To Live Parts) |
- |
|
|
|
Cl.10 of IS 302-2- 35:2011 (Power Input & Current ) |
- |
|
|
|
Cl.11 of 302-2-35:2017 (Heating) |
- |
|
|
|
Cl.11 of 302-2-35:2017 (Heating) |
- |
|
|
|
Cl.11 of 302-2-35:2017 (Heating) |
- |
|
|
|
Cl.11 of 302-2-35:2017 (Heating) |
- |
|
|
|
Cl.13 of IS 302-2-35:2017 (Leakage Current & Electrical Strength at Operating Temperature ) |
- |
|
|
|
Cl.13 of IS 302-2-35:2017 (Leakage Current & Electrical Strength at Operating Temperature ) |
- |
|
|
|
Cl.15 of IS 302-2-35-2011 (Moisture Resistance ) |
- |
|
|
|
Cl.15 of IS 302-2-35-2011 (Moisture Resistance ) |
- |
|
|
|
Cl.16 of IS 302-2-35:2011 (Leakage Current and Electric Strength) |
- |
|
|
|
Cl.16 of IS 302-2-35:2011 (Leakage Current and Electric Strength) |
- |
|
|
|
Cl.19 of IS 302-2-35:2017 (Abnormal Operation) |
- |
|
|
|
Cl.19 of IS 302-2-35:2017 (Abnormal Operation) |
- |
|
|
|
Cl.19 of IS 302-2-35:2017 (Abnormal Operation) |
- |
|
|
|
Cl.19 of IS 302-2-35:2017 (Abnormal Operation) |
- |
|
|
|
Cl.20 of IS 302-2-35-2011 (Stability & Mechanical Hazards
) |
- |
|
|
|
Cl.21.1 of IS 302-2-35-2011 (Mechanical strength) |
- |
|
|
|
Cl.22 of IS 302-2-35-2011 (Construction
) |
- |
|
|
|
Cl.22 of IS 302-2-35-2011 (Construction
) |
- |
|
|
|
Cl.22 of IS 302-2-35-2011 (Construction
) |
- |
|
|
|
Cl.22 of IS 302-2-35-2011 (Construction
) |
- |
|
|
|
Cl.22 of IS 302-2-35-2011 (Construction
) |
- |
|
|
|
Cl.22 of IS 302-2-35-2011 (Construction
) |
- |
|
|
|
Cl.22 of IS 302-2-35-2011 (Construction
) |
- |
|
|
|
Cl.22 of IS 302-2-35-2011 (Construction
) |
- |
|
|
|
Cl.22 of IS 302-2-35-2011 (Construction
) |
- |
|
|
|
Cl.22 of IS 302-2-35-2011 (Construction
) |
- |
|
|
|
Cl.22 of IS 302-2-35-2011 (Construction
) |
- |
|
|
|
Cl.22 of IS 302-2-35-2011 (Construction
) |
- |
|
|
|
Cl.22 of IS 302-2-35-2011 (Construction
) |
- |
|
|
|
Cl.22 of IS 302-2-35-2011 (Construction
) |
- |
|
|
|
Cl.22 of IS 302-2-35-2011 (Construction
) |
- |
|
|
|
Cl.22 of IS 302-2-35-2011 (Construction
) |
- |
|
|
|
Cl.22 of IS 302-2-35-2011 (Construction
) |
- |
|
|
|
Cl.22 of IS 302-2-35-2011 (Construction
) |
- |
|
|
|
Cl.22 of IS 302-2-35-2011 (Construction
) |
- |
|
|
|
Cl.22 of IS 302-2-35-2011 (Construction
) |
- |
|
|
|
Cl.22 of IS 302-2-35-2011 (Construction
) |
- |
|
|
|
Cl.22 of IS 302-2-35-2011 (Construction
) |
- |
|
|
|
Cl.22 of IS 302-2-35-2011 (Construction
) |
- |
|
|
|
Cl.22 of IS 302-2-35-2011 (Construction
) |
- |
|
|
|
Cl.22 of IS 302-2-35-2011 (Construction
) |
- |
|
|
|
Cl.22 of IS 302-2-35-2011 (Construction
) |
- |
|
|
|
Cl.22 of IS 302-2-35-2011 (Construction
) |
- |
|
|
|
Cl.22 of IS 302-2-35-2011 (Construction
) |
- |
|
|
|
Cl.22 of IS 302-2-35-2011 (Construction
) |
- |
|
|
|
Cl.22 of IS 302-2-35-2011 (Construction
) |
- |
|
|
|
Cl.22 of IS 302-2-35-2011 (Construction
) |
- |
|
|
|
Cl.22 of IS 302-2-35-2011 (Construction
) |
- |
|
|
|
Cl.22 of IS 302-2-35-2011 (Construction
) |
- |
|
|
|
Cl.22 of IS 302-2-35-2011 (Construction
) |
- |
|
|
|
Cl.22 of IS 302-2-35-2011 (Construction
) |
- |
|
|
|
Cl.22 of IS 302-2-35-2011 (Construction
) |
- |
|
|
|
Cl.22 of IS 302-2-35-2011 (Construction
) |
- |
|
|
|
Cl.22 of IS 302-2-35-2011 (Construction
) |
- |
|
|
|
Cl.22 of IS 302-2-35-2011 (Construction
) |
- |
|
|
|
Cl.22 of IS 302-2-35-2011 (Construction
) |
- |
|
|
|
Cl.22 of IS 302-2-35-2011 (Construction
) |
- |
|
|
|
Cl.22 of IS 302-2-35-2011 (Construction
) |
- |
|
|
|
Cl.22 of IS 302-2-35-2011 (Construction
) |
- |
|
|
|
Cl.22 of IS 302-2-35-2011 (Construction
) |
- |
|
|
|
Cl.22 of IS 302-2-35-2011 (Construction
) |
- |
|
|
|
Cl.22 of IS 302-2-35-2011 (Construction
) |
- |
|
|
|
Cl.22 of IS 302-2-35-2011 (Construction
) |
- |
|
|
|
Cl.22 of IS 302-2-35-2011 (Construction
) |
- |
|
|
|
Cl.22 of IS 302-2-35-2011 (Construction
) |
- |
|
|
|
Cl.22 of IS 302-2-35-2011 (Construction
) |
- |
|
|
|
Cl.22 of IS 302-2-35-2011 (Construction
) |
- |
|
|
|
Cl.22 of IS 302-2-35-2011 (Construction
) |
- |
|
|
|
Cl.23 of IS 302-2-35-2011 (Internal Wiring) |
- |
|
|
|
Cl.23 of IS 302-2-35-2011 (Internal Wiring) |
- |
|
|
|
Cl.23 of IS 302-2-35-2011 (Internal Wiring) |
- |
|
|
|
Cl.23 of IS 302-2-35-2011 (Internal Wiring) |
- |
|
|
|
Cl.23 of IS 302-2-35-2011 (Internal Wiring) |
- |
|
|
|
Cl.23 of IS 302-2-35-2011 (Internal Wiring) |
- |
|
|
|
Cl.23 of IS 302-2-35-2011 (Internal Wiring) |
- |
|
|
|
Cl.23 of IS 302-2-35-2011 (Internal Wiring) |
- |
|
|
|
Cl.23 of IS 302-2-35-2011 (Internal Wiring) |
- |
|
|
|
Cl.23 of IS 302-2-35-2011 (Internal Wiring) |
- |
|
|
|
Cl.23 of IS 302-2-35-2011 (Internal Wiring) |
- |
|
|
|
Cl.23 of IS 302-2-35-2011 (Internal Wiring) |
- |
|
|
|
Cl.23 of IS 302-2-35-2011 (Internal Wiring) |
- |
|
|
|
Cl.24 of IS 302-2-35:2017 (Component
) |
- |
|
|
|
Cl.24 of IS 302-2-35:2017 (Component
) |
- |
|
|
|
Cl.24 of IS 302-2-35:2017 (Component
) |
- |
|
|
|
Cl.24 of IS 302-2-35:2017 (Component
) |
- |
|
|
|
Cl.24 of IS 302-2-35:2017 (Component
) |
- |
|
|
|
Cl.25 of IS 302-2-35:2017 (Supply Connection & External Flexible Cords) |
- |
|
|
|
Cl.25 of IS 302-2-35:2017 (Supply Connection & External Flexible Cords) |
- |
|
|
|
Cl.25 of IS 302-2-35:2017 (Supply Connection & External Flexible Cords) |
- |
|
|
|
Cl.25 of IS 302-2-35:2017 (Supply Connection & External Flexible Cords) |
- |
|
|
|
Cl.25 of IS 302-2-35:2017 (Supply Connection & External Flexible Cords) |
- |
|
|
|
Cl.25 of IS 302-2-35:2017 (Supply Connection & External Flexible Cords) |
- |
|
|
|
Cl.25 of IS 302-2-35:2017 (Supply Connection & External Flexible Cords) |
- |
|
|
|
Cl.25 of IS 302-2-35:2017 (Supply Connection & External Flexible Cords) |
- |
|
|
|
Cl.25 of IS 302-2-35:2017 (Supply Connection & External Flexible Cords) |
- |
|
|
|
Cl.25 of IS 302-2-35:2017 (Supply Connection & External Flexible Cords) |
- |
|
|
|
Cl.25 of IS 302-2-35:2017 (Supply Connection & External Flexible Cords) |
- |
|
|
|
Cl.25 of IS 302-2-35:2017 (Supply Connection & External Flexible Cords) |
- |
|
|
|
Cl.25 of IS 302-2-35:2017 (Supply Connection & External Flexible Cords) |
- |
|
|
|
Cl.25 of IS 302-2-35:2017 (Supply Connection & External Flexible Cords) |
- |
|
|
|
Cl.25 of IS 302-2-35:2017 (Supply Connection & External Flexible Cords) |
- |
|
|
|
Cl.25 of IS 302-2-35:2017 (Supply Connection & External Flexible Cords) |
- |
|
|
|
Cl.25 of IS 302-2-35:2017 (Supply Connection & External Flexible Cords) |
- |
|
|
|
Cl.25 of IS 302-2-35:2017 (Supply Connection & External Flexible Cords) |
- |
|
|
|
Cl.25 of IS 302-2-35:2017 (Supply Connection & External Flexible Cords) |
- |
|
|
|
Cl.25 of IS 302-2-35:2017 (Supply Connection & External Flexible Cords) |
- |
|
|
|
Cl.25 of IS 302-2-35:2017 (Supply Connection & External Flexible Cords) |
- |
|
|
|
Cl.25 of IS 302-2-35:2017 (Supply Connection & External Flexible Cords) |
- |
|
|
|
Cl.25 of IS 302-2-35:2017 (Supply Connection & External Flexible Cords) |
- |
|
|
|
Cl.25 of IS 302-2-35:2017 (Supply Connection & External Flexible Cords) |
- |
|
|
|
Cl.25 of IS 302-2-35:2017 (Supply Connection & External Flexible Cords) |
- |
|
|
|
Cl.26 of IS 302-2-35:2017 (Terminals for External Conductors) |
- |
|
|
|
Cl.26 of IS 302-2-35:2017 (Terminals for External Conductors) |
- |
|
|
|
Cl.26 of IS 302-2-35:2017 (Terminals for External Conductors) |
- |
|
|
|
Cl.26 of IS 302-2-35:2017 (Terminals for External Conductors) |
- |
|
|
|
Cl.26 of IS 302-2-35:2017 (Terminals for External Conductors) |
- |
|
|
|
Cl.26 of IS 302-2-35:2017 (Terminals for External Conductors) |
- |
|
|
|
Cl.26 of IS 302-2-35:2017 (Terminals for External Conductors) |
- |
|
|
|
Cl.26 of IS 302-2-35:2017 (Terminals for External Conductors) |
- |
|
|
|
Cl.26 of IS 302-2-35:2017 (Terminals for External Conductors) |
- |
|
|
|
Cl.26 of IS 302-2-35:2017 (Terminals for External Conductors) |
- |
|
|
|
Cl.26 of IS 302-2-35:2017 (Terminals for External Conductors) |
- |
|
|
|
Cl.27 of IS 302-2-35:2017 (Provision for Earthing) |
- |
|
|
|
Cl.27 of IS 302-2-35:2017 (Provision for Earthing) |
- |
|
|
|
Cl.27 of IS 302-2-35:2017 (Provision for Earthing) |
- |
|
|
|
Cl.27 of IS 302-2-35:2017 (Provision for Earthing) |
- |
|
|
|
Cl.27 of IS 302-2-35:2017 (Provision for Earthing) |
- |
|
|
|
Cl.27 of IS 302-2-35:2017 (Provision for Earthing) |
- |
|
|
|
Cl.27 of IS 302-2-35:2017 (Provision for Earthing) |
- |
|
|
|
Cl.28 of IS 302-2-35:2017 (Screws and Connections
) |
- |
|
|
|
Cl.29 of IS 302-2-35:2017 (Clearances, Creepage Distances and Solid Insulation) |
- |
|
|
|
Cl.29 of IS 302-2-35:2017 (Clearances, Creepage Distances and Solid Insulation) |
- |
|
|
|
Cl.29 of IS 302-2-35:2017 (Clearances, Creepage Distances and Solid Insulation) |
- |
|
|
|
Cl.30 of IS 302-2-35: 2011 (Resistance to Heat and Fire) |
- |
|
|
|
Cl.30 of IS 302-2-35: 2011 (Resistance to Heat and Fire) |
- |
|
|
|
Cl.31 of IS 302-2-35: 2011 (Resistance to Rusting
) |
- |
|
|
|
Cl.32 of IS 302-2-35: 2011 (Radiation, Toxicity and Similar Hazards
) |
- |
|
|
|
Cl.10 of IS 8978 : 1992 (Finish) |
- |
|
|
|
Cl.11 of IS 8978 : 1992 (Operation of flow switch) |
- |
|
|
|
Cl.12 of IS 8978 : 1992 (Endurance) |
- |
|
|
|
Cl.7 of IS 302-2-35:2017 (Marking) |
- |
|
|
|
Cl.7 of IS 302-2-35:2017 (Marking) |
- |
|
|
|
Cl.7 of IS 302-2-35:2017 (Marking) |
- |
|
|
|
Cl.7 of IS 302-2-35:2017 (Marking) |
- |
|
|
|
Cl.7 of IS 302-2-35:2017 (Marking) |
- |
|
|
|
Cl.7 of IS 302-2-35:2017 (Marking) |
- |
|
|
|
Cl.7 of IS 302-2-35:2017 (Marking) |
- |
|
|
|
Cl.7 of IS 302-2-35:2017 (Marking) |
- |
|
|
|
Cl.7 of IS 302-2-35:2017 (Marking) |
- |
|
|
|
Cl.7 of IS 302-2-35:2017 (Marking) |
- |
|
|
|
Cl.7 of IS 302-2-35:2017 (Marking) |
- |
|
|
|
Cl.7 of IS 302-2-35:2017 (Marking) |
- |
|
|
|
Cl.7 of IS 302-2-35:2017 (Marking) |
- |
|
|
|
Cl.7 of IS 302-2-35:2017 (Marking) |
- |
|
|
|
Cl.7 of IS 302-2-35:2017 (Marking) |
- |
|
|
|
Cl.7 of IS 302-2-35:2017 (Marking) |
- |
|
|
|
Cl.7 of IS 302-2-35:2017 (Marking) |
- |
|
|
|
Cl.7 of IS 302-2-35:2017 (Marking) |
- |
|
|
|
Cl.7 of IS 302-2-35:2017 (Marking) |
- |
|
|
|
Cl.7 of IS 302-2-35:2017 (Marking) |
- |
|
|
|
Cl.7 of IS 302-2-35:2017 (Marking) |
- |
|
|
|
Cl.7 of IS 302-2-35:2017 (Marking) |
- |
|
|
|
Cl.7 of IS 302-2-35:2017 (Marking) |
- |
|
|
|
Cl. 21.2 of IS 302-1:2008 (Mechanical strength) |
- |
|
|
|
|
Partial
|
|
- |
Excluding Cl 22.105 Operation of electronic circuit and software evaulation annnex R
Cl. 22.108 Fault condition for electronic condition and software evaulation annnex R
Cl. 24.1.3 test on components and water heaters above 3kW"
Cl. 19.11 and Cl. 19.12 abnormal test (for Electronic circuit) |
129 |
IS 4250 (1980) |
Specification for domestic electric food - Mixers (Liquidizers And Grinders) (First Revision) |
- |
-
|
- View breakup
Rs 9750/- Excluding Endurance test for juicers
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
6 (Classification- IS 302-1 ) |
- |
|
|
|
6 (Classification- IS 302-1) |
- |
|
|
|
7.1 (Marking- IS 302-1) |
- |
|
|
|
7.1 (Marking- IS 302-1) |
- |
|
|
|
7.1 (Marking- IS 302-1) |
- |
|
|
|
7.1 (Marking- IS 302-1) |
- |
|
|
|
7.1 (Marking- IS 302-1) |
- |
|
|
|
7.1 (Marking- IS 302-1) |
- |
|
|
|
7.1 (Marking- IS 302-1) |
- |
|
|
|
7.1 (Marking- IS 302-1) |
- |
|
|
|
7.1 (Marking- IS 302-1) |
- |
|
|
|
7.1 (Marking- IS 302-1) |
- |
|
|
|
7.1 (Marking- IS 302-1) |
- |
|
|
|
7.1 (Marking- IS 302-1) |
- |
|
|
|
7.2 (Marking) |
- |
|
|
|
7.1 (Marking- IS 302-1) |
- |
|
|
|
7.1 (Marking- IS 302-1) |
- |
|
|
|
7.1 (Marking- IS 302-1) |
- |
|
|
|
7.4 (Marking) |
- |
|
|
|
7.5 (Marking) |
- |
|
|
|
7.6 (Marking) |
- |
|
|
|
8 ( Protection Against Electric Shock, IS 302-1) |
- |
|
|
|
9 (Starting, IS 302-1) |
- |
|
|
|
10 (Power Input and Current, IS 302-1) |
- |
|
|
|
11 (Heating, IS 302-1) |
- |
|
|
|
11 (Heating, IS 302-1) |
- |
|
|
|
11 (Heating, IS 302-1) |
- |
|
|
|
11 (Heating, IS 302-1) |
- |
|
|
|
11 (Heating, IS 302-1) |
- |
|
|
|
13 (Electrical Insulation and Leakage Current at Operating Temperature: Leakage current, IS 302-1) |
- |
|
|
|
16 (Electrical Insulation and Leakage Current at Operating Temperature: Leakage current, IS 302-1) |
- |
|
|
|
13 (Electrical Insulation and Leakage Current at Operating Temperature: High Voltage, IS 302-1) |
- |
|
|
|
15.2 (Moisture Resistance-Spillage test) |
- |
|
|
|
15 (Moisture Resistance, IS 302-1) |
- |
|
|
|
16 (Electrical Insulation and Leakage Current at Operating Temperature: Leakage current, IS 302-1) |
- |
|
|
|
16 (Electrical Insulation and Leakage Current at Operating Temperature: High Voltage, IS 302-1) |
- |
|
|
|
11 (Heating, IS 302-1) |
- |
|
|
|
19 (Abnormal Operation, IS 302-1) |
- |
|
|
|
11 (Heating, IS 302-1) |
- |
|
|
|
19 (Abnormal Operation, IS 302-1) |
- |
|
|
|
19 (Abnormal Operation, IS 302-1) |
- |
|
|
|
19 (Abnormal Operation, IS 302-1) |
- |
|
|
|
19 (Abnormal Operation, IS 302-1) |
- |
|
|
|
20 (Stability & Mechanical Hazards, IS 302-1) |
- |
|
|
|
20 (Stability & Mechanical Hazards, IS 302-1) |
- |
|
|
|
21 (Mechanical Strength, IS 302-1) |
- |
|
|
|
20 (Stability & Mechanical Hazards, IS 302-1) |
- |
|
|
|
21 (Mechanical Strength, IS 302-1) |
- |
|
|
|
21 (Mechanical Strength, IS 302-1) |
- |
|
|
|
22.1 (Construction, IS 302-1) |
- |
|
|
|
22.2 (Construction) |
- |
|
|
|
22.3 (Construction) |
- |
|
|
|
22.4 (Construction) |
- |
|
|
|
22.5 (Construction) |
- |
|
|
|
24.6 (Components) |
- |
|
|
|
24.7 (Components) |
- |
|
|
|
22.9 (Construction) |
- |
|
|
|
22.1 (Construction) |
- |
|
|
|
23 (Internal Wiring, IS 302-1) |
- |
|
|
|
23 (Internal Wiring, IS 302-1) |
- |
|
|
|
23 (Internal Wiring, IS 302-1) |
- |
|
|
|
23 (Internal Wiring, IS 302-1) |
- |
|
|
|
23 (Internal Wiring, IS 302-1) |
- |
|
|
|
23 (Internal Wiring, IS 302-1) |
- |
|
|
|
23 (Internal Wiring, IS 302-1) |
- |
|
|
|
23 (Internal Wiring, IS 302-1) |
- |
|
|
|
23 (Internal Wiring, IS 302-1) |
- |
|
|
|
24.1 (Components, IS 302-1) |
- |
|
|
|
24.1 (Components, IS 302-1) |
- |
|
|
|
24.1 (Components, IS 302-1) |
- |
|
|
|
24.1 (Components, IS 302-1) |
- |
|
|
|
24.2 (Components) |
- |
|
|
|
24.4 (Components) |
- |
|
|
|
24.5 (Components) |
- |
|
|
|
24.6 (Components) |
- |
|
|
|
24.7 (Components) |
- |
|
|
|
24.8 (Components) |
- |
|
|
|
24.9 (Components) |
- |
|
|
|
25 (Supply Connection and External Flexible Cords, IS 302-1) |
- |
|
|
|
25 (Supply Connection and External Flexible Cords, IS 302-1) |
- |
|
|
|
25 (Supply Connection and External Flexible Cords, IS 302-1) |
- |
|
|
|
25 (Supply Connection and External Flexible Cords, IS 302-1) |
- |
|
|
|
25 (Supply Connection and External Flexible Cords, IS 302-1) |
- |
|
|
|
25 (Supply Connection and External Flexible Cords, IS 302-1) |
- |
|
|
|
23 (Internal Wiring, IS 302-1) |
- |
|
|
|
25 (Supply Connection and External Flexible Cords, IS 302-1) |
- |
|
|
|
25 (Supply Connection and External Flexible Cords, IS 302-1) |
- |
|
|
|
25 (Supply Connection and External Flexible Cords, IS 302-1) |
- |
|
|
|
25 (Supply Connection and External Flexible Cords, IS 302-1) |
- |
|
|
|
25 (Supply Connection and External Flexible Cords, IS 302-1) |
- |
|
|
|
25 (Supply Connection and External Flexible Cords, IS 302-1) |
- |
|
|
|
25 (Supply Connection and External Flexible Cords, IS 302-1) |
- |
|
|
|
25 (Supply Connection and External Flexible Cords, IS 302-1) |
- |
|
|
|
25 (Supply Connection and External Flexible Cords, IS 302-1) |
- |
|
|
|
26 (Terminals for External Conductors, IS 302-1) |
- |
|
|
|
27 (Provision for Earthing, IS 302-1) |
- |
|
|
|
27 (Provision for Earthing, IS 302-1) |
- |
|
|
|
27 (Provision for Earthing, IS 302-1) |
- |
|
|
|
27 (Provision for Earthing, IS 302-1) |
- |
|
|
|
28 (Screws & Connections, IS 302-1) |
- |
|
|
|
29 (Clearances and Distances through Insulation, IS 302-1) |
- |
|
|
|
29 (Clearances and Distances through Insulation, IS 302-1) |
- |
|
|
|
30 (Resistance to Heat, Fire, Tracking, IS 302-1) |
- |
|
|
|
30 (Resistance to Heat, Fire, Tracking, IS 302-1) |
- |
|
|
|
34.2 (Operational tests- Grinding coffee (for machines which have a dry grinding arrangement)) |
- |
|
|
|
34.2 (Operational tests- Grinding coffee (for machines which have a dry grinding arrangement)) |
- |
|
|
|
34.4 (IDLI batter-Grinding of black gram) |
- |
|
|
|
34.4 (IDLI batter-Grinding of rice) |
- |
|
|
|
34.2 (Operational tests- Grinding coffee (for machines which have a dry grinding arrangement)) |
- |
|
|
|
34.4 (IDLI batter-Grinding of rice) |
- |
|
|
|
34.5.1 (a) (Operational test for juicers ) |
- |
|
|
|
34.5.1 (b) (Operational test for juicers ) |
- |
|
|
|
34.5.2 (Operational test for juicers ) |
- |
|
|
|
35 (Temperature withstand test for bowl) |
- |
|
|
|
36 (Test for controls ) |
- |
|
|
|
37 (Strength of Assembly ) |
- |
|
|
|
37 (Strength of Assembly ) |
- |
|
|
|
|
Partial
|
|
- |
Excluding 1. Cl. 14 Transient Overvoltage Test IS 302-1:2008 2. Cl. 19.11 and Cl. 19.12 abnormal test (for Electronic circuit) 3. Cl.24 Component Test IS 302-1:2008 |
130 |
IS 369 (2019) |
Household electric direct - Acting room heaters - Performance requirements (Fourth Revision) |
- |
-
|
- View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
Cl.6 of IS 302-2-30:2007 (Classification) |
- |
|
|
|
Cl.6 of IS 302-2-30:2007 (Classification) |
- |
|
|
|
Cl.7 of IS 302-2-30:2007 &IS:302-1:2008 (Marking and Instructions) |
- |
|
|
|
Cl.7 of IS 302-2-30:2007 &IS:302-1:2008 (Marking and Instructions) |
- |
|
|
|
Cl.7 of IS 302-2-30:2007 &IS:302-1:2008 (Marking and Instructions) |
- |
|
|
|
Cl.7 of IS 302-2-30:2007 &IS:302-1:2008 (Marking and Instructions) |
- |
|
|
|
Cl.7 of IS 302-2-30:2007 &IS:302-1:2008 (Marking and Instructions) |
- |
|
|
|
Cl.7 of IS 302-2-30:2007 &IS:302-1:2008 (Marking and Instructions) |
- |
|
|
|
Cl.7 of IS 302-2-30:2007 &IS:302-1:2008 (Marking and Instructions) |
- |
|
|
|
Cl.7 of IS 302-2-30:2007 &IS:302-1:2008 (Marking and Instructions) |
- |
|
|
|
Cl.7 of IS 302-2-30:2007 &IS:302-1:2008 (Marking and Instructions) |
- |
|
|
|
Cl.7 of IS 302-2-30:2007 &IS:302-1:2008 (Marking and Instructions) |
- |
|
|
|
Cl.7 of IS 302-2-30:2007 &IS:302-1:2008 (Marking and Instructions) |
- |
|
|
|
Cl.7 of IS 302-2-30:2007 &IS:302-1:2008 (Marking and Instructions) |
- |
|
|
|
Cl.7 of IS 302-2-30:2007 &IS:302-1:2008 (Marking and Instructions) |
- |
|
|
|
Cl.7 of IS 302-2-30:2007 &IS:302-1:2008 (Marking and Instructions) |
- |
|
|
|
Cl.7 of IS 302-2-30:2007 &IS:302-1:2008 (Marking and Instructions) |
- |
|
|
|
Cl.7 of IS 302-2-30:2007 &IS:302-1:2008 (Marking and Instructions) |
- |
|
|
|
Cl.7 of IS 302-2-30:2007 &IS:302-1:2008 (Marking and Instructions) |
- |
|
|
|
Cl.7 of IS 302-2-30:2007 &IS:302-1:2008 (Marking and Instructions) |
- |
|
|
|
Cl.7 of IS 302-2-30:2007 &IS:302-1:2008 (Marking and Instructions) |
- |
|
|
|
Cl.7 of IS 302-2-30:2007 &IS:302-1:2008 (Marking and Instructions) |
- |
|
|
|
Cl.7 of IS 302-2-30:2007 &IS:302-1:2008 (Marking and Instructions) |
- |
|
|
|
Cl.7 of IS 302-2-30:2007 &IS:302-1:2008 (Marking and Instructions) |
- |
|
|
|
Cl.7 of IS 302-2-30:2007 &IS:302-1:2008 (Marking and Instructions) |
- |
|
|
|
Cl.7 of IS 302-2-30:2007 &IS:302-1:2008 (Marking and Instructions) |
- |
|
|
|
Cl.7 of IS 302-2-30:2007 &IS:302-1:2008 (Marking and Instructions) |
- |
|
|
|
Cl.7 of IS 302-2-30:2007 &IS:302-1:2008 (Marking and Instructions) |
- |
|
|
|
Cl.7 of IS 302-2-30:2007 &IS:302-1:2008 (Marking and Instructions) |
- |
|
|
|
Cl.7 of IS 302-2-30:2007 &IS:302-1:2008 (Marking and Instructions) |
- |
|
|
|
Cl.7 of IS 302-2-30:2007 &IS:302-1:2008 (Marking and Instructions) |
- |
|
|
|
Cl.7 of IS 302-2-30:2007 &IS:302-1:2008 (Marking and Instructions) |
- |
|
|
|
Cl.7 of IS 302-2-30:2007 &IS:302-1:2008 (Marking and Instructions) |
- |
|
|
|
Cl.7 of IS 302-2-30:2007 &IS:302-1:2008 (Marking and Instructions) |
- |
|
|
|
Cl.7 of IS 302-2-30:2007 &IS:302-1:2008 (Marking and Instructions) |
- |
|
|
|
Cl.7 of IS 302-2-30:2007 &IS:302-1:2008 (Marking and Instructions) |
- |
|
|
|
Cl.7 of IS 302-2-30:2007 &IS:302-1:2008 (Marking and Instructions) |
- |
|
|
|
Cl.7 of IS 302-2-30:2007 &IS:302-1:2008 (Marking and Instructions) |
- |
|
|
|
Cl.7 of IS 302-2-30:2007 &IS:302-1:2008 (Marking and Instructions) |
- |
|
|
|
Cl.7 of IS 302-2-30:2007 &IS:302-1:2008 (Marking and Instructions) |
- |
|
|
|
Cl.7 of IS 302-2-30:2007 &IS:302-1:2008 (Marking and Instructions) |
- |
|
|
|
Cl.7 of IS 302-2-30:2007 &IS:302-1:2008 (Marking and Instructions) |
- |
|
|
|
Cl.7 of IS 302-2-30:2007 &IS:302-1:2008 (Marking and Instructions) |
- |
|
|
|
Cl.7 of IS 302-2-30:2007 &IS:302-1:2008 (Marking and Instructions) |
- |
|
|
|
Cl.7 of IS 302-2-30:2007 &IS:302-1:2008 (Marking and Instructions) |
- |
|
|
|
Cl.7 of IS 302-2-30:2007 &IS:302-1:2008 (Marking and Instructions) |
- |
|
|
|
Cl.7 of IS 302-2-30:2007 &IS:302-1:2008 (Marking and Instructions) |
- |
|
|
|
Cl.7 of IS 302-2-30:2007 &IS:302-1:2008 (Marking and Instructions) |
- |
|
|
|
Cl.7 of IS 302-2-30:2007 &IS:302-1:2008 (Marking and Instructions) |
- |
|
|
|
Cl.7 of IS 302-2-30:2007 &IS:302-1:2008 (Marking and Instructions) |
- |
|
|
|
Cl.7 of IS 302-2-30:2007 &IS:302-1:2008 (Marking and Instructions) |
- |
|
|
|
Cl.7 of IS 302-2-30:2007 &IS:302-1:2008 (Marking and Instructions) |
- |
|
|
|
Cl.7 of IS 302-2-30:2007 &IS:302-1:2008 (Marking and Instructions) |
- |
|
|
|
Cl.7 of IS 302-2-30:2007 &IS:302-1:2008 (Marking and Instructions) |
- |
|
|
|
Cl.7 of IS 302-2-30:2007 &IS:302-1:2008 (Marking and Instructions) |
- |
|
|
|
Cl.7 of IS 302-2-30:2007 &IS:302-1:2008 (Marking and Instructions) |
- |
|
|
|
Cl.7 of IS 302-2-30:2007 &IS:302-1:2008 (Marking and Instructions) |
- |
|
|
|
Cl.8 of IS 302-2-30:2007 &IS:302-1:2008 (Protection Against Access to Live Parts) |
- |
|
|
|
Cl.10 of IS 302-2-30:2007 &IS:302-1:2008 (Power Input and Current) |
- |
|
|
|
Cl.11 of IS 302-2-30:2007 &IS:302-1:2008 (Heating) |
- |
|
|
|
Cl.7 of IS 302-2-30:2007 &IS:302-1:2008 (Marking and Instructions) |
- |
|
|
|
Cl.11 of IS 302-2-30:2007 &IS:302-1:2008 (Heating) |
- |
|
|
|
Cl.11 of IS 302-2-30:2007 &IS:302-1:2008 (Heating) |
- |
|
|
|
Cl.11 of IS 302-2-30:2007 &IS:302-1:2008 (Heating) |
- |
|
|
|
Cl.11 of IS 302-2-30:2007 &IS:302-1:2008 (Heating) |
- |
|
|
|
Cl.11 of IS 302-2-30:2007 &IS:302-1:2008 (Heating) |
- |
|
|
|
Cl.11 of IS 302-2-30:2007 &IS:302-1:2008 (Heating) |
- |
|
|
|
Cl.11 of IS 302-2-30:2007 &IS:302-1:2008 (Heating) |
- |
|
|
|
Cl.11 of IS 302-2-30:2007 &IS:302-1:2008 (Heating) |
- |
|
|
|
Cl.11 of IS 302-2-30:2007 &IS:302-1:2008 (Heating) |
- |
|
|
|
Cl.11 of IS 302-2-30:2007 &IS:302-1:2008 (Heating) |
- |
|
|
|
Cl.11 of IS 302-2-30:2007 &IS:302-1:2008 (Heating) |
- |
|
|
|
Cl.11 of IS 302-2-30:2007 &IS:302-1:2008 (Heating) |
- |
|
|
|
Cl.11 of IS 302-2-30:2007 &IS:302-1:2008 (Heating) |
- |
|
|
|
Cl.11 of IS 302-2-30:2007 &IS:302-1:2008 (Heating) |
- |
|
|
|
Cl.11 of IS 302-2-30:2007 &IS:302-1:2008 (Heating) |
- |
|
|
|
Cl.11 of IS 302-2-30:2007 &IS:302-1:2008 (Heating) |
- |
|
|
|
Cl.11 of IS 302-2-30:2007 &IS:302-1:2008 (Heating) |
- |
|
|
|
Cl.11 of IS 302-2-30:2007 &IS:302-1:2008 (Heating) |
- |
|
|
|
Cl.11 of IS 302-2-30:2007 &IS:302-1:2008 (Heating) |
- |
|
|
|
Cl.11 of IS 302-2-30:2007 &IS:302-1:2008 (Heating) |
- |
|
|
|
Cl.11 of IS 302-2-30:2007 &IS:302-1:2008 (Heating) |
- |
|
|
|
Cl.11 of IS 302-2-30:2007 &IS:302-1:2008 (Heating) |
- |
|
|
|
Cl.11 of IS 302-2-30:2007 &IS:302-1:2008 (Heating) |
- |
|
|
|
Cl.11 of IS 302-2-30:2007 &IS:302-1:2008 (Heating) |
- |
|
|
|
Cl.13 of IS 302-2-30:2007 &IS:302-1:2008 (Leakage Current & Electric Strength at operating temp) |
- |
|
|
|
Cl.16 of IS 302-2-30:2007 &IS:302-1:2008 (Leakage Current & Electric Strength ) |
- |
|
|
|
Cl.13 of IS 302-2-30:2007 &IS:302-1:2008 (Leakage Current & Electric Strength at operating temp) |
- |
|
|
|
Cl.15 of IS 302-2-30:2007 &IS:302-1:2008 (Moisture Resistance) |
- |
|
|
|
Cl.15 of IS 302-2-30:2007 &IS:302-1:2008 (Moisture Resistance) |
- |
|
|
|
Cl.16 of IS 302-2-30:2007 &IS:302-1:2008 (Leakage Current & Electric Strength ) |
- |
|
|
|
Cl.16 of IS 302-2-30:2007 &IS:302-1:2008 (Leakage Current & Electric Strength ) |
- |
|
|
|
Cl.19 of IS 302-2-30:2007 &IS:302-1:2008 (Abnormal Operation) |
- |
|
|
|
Cl.19 of IS 302-2-30:2007 &IS:302-1:2008 (Abnormal Operation) |
- |
|
|
|
Cl.11 of IS 302-2-30:2007 &IS:302-1:2008 (Heating) |
- |
|
|
|
Cl.11 of IS 302-2-30:2007 &IS:302-1:2008 (Heating) |
- |
|
|
|
Cl.11 of IS 302-2-30:2007 &IS:302-1:2008 (Heating) |
- |
|
|
|
Cl.11 of IS 302-2-30:2007 &IS:302-1:2008 (Heating) |
- |
|
|
|
Cl.19 of IS 302-2-30:2007 &IS:302-1:2008 (Abnormal Operation) |
- |
|
|
|
Cl.19 of IS 302-2-30:2007 &IS:302-1:2008 (Abnormal Operation) |
- |
|
|
|
Cl.19 of IS 302-2-30:2007 &IS:302-1:2008 (Abnormal Operation) |
- |
|
|
|
Cl.11 of IS 302-2-30:2007 &IS:302-1:2008 (Heating) |
- |
|
|
|
Cl.19 of IS 302-2-30:2007 &IS:302-1:2008 (Abnormal Operation) |
- |
|
|
|
Cl.19 of IS 302-2-30:2007 &IS:302-1:2008 (Abnormal Operation) |
- |
|
|
|
Cl.11 of IS 302-2-30:2007 &IS:302-1:2008 (Heating) |
- |
|
|
|
Cl.19 of IS 302-2-30:2007 &IS:302-1:2008 (Abnormal Operation) |
- |
|
|
|
Cl.19 of IS 302-2-30:2007 &IS:302-1:2008 (Abnormal Operation) |
- |
|
|
|
Cl.19 of IS 302-2-30:2007 &IS:302-1:2008 (Abnormal Operation) |
- |
|
|
|
Cl.19 of IS 302-2-30:2007 &IS:302-1:2008 (Abnormal Operation) |
- |
|
|
|
Cl.19 of IS 302-2-30:2007 &IS:302-1:2008 (Abnormal Operation) |
- |
|
|
|
Cl.19 of IS 302-2-30:2007 &IS:302-1:2008 (Abnormal Operation) |
- |
|
|
|
Cl.19 of IS 302-2-30:2007 &IS:302-1:2008 (Abnormal Operation) |
- |
|
|
|
Cl.19 of IS 302-2-30:2007 &IS:302-1:2008 (Abnormal Operation) |
- |
|
|
|
Cl.19 of IS 302-2-30:2007 &IS:302-1:2008 (Abnormal Operation) |
- |
|
|
|
Cl.19 of IS 302-2-30:2007 &IS:302-1:2008 (Abnormal Operation) |
- |
|
|
|
Cl.20 of IS 302-2-30:2007 &IS:302-1:2008 (Stability & Mechanical Hazards) |
- |
|
|
|
Cl.21 of IS 302-2-30:2007 &IS:302-1:2008 (Mechanical Strength) |
- |
|
|
|
Cl.21 of IS 302-2-30:2007 &IS:302-1:2008 (Mechanical Strength) |
- |
|
|
|
Cl.21 of IS 302-2-30:2007 &IS:302-1:2008 (Mechanical Strength) |
- |
|
|
|
Cl.21 of IS 302-2-30:2007 &IS:302-1:2008 (Mechanical Strength) |
- |
|
|
|
Cl.21 of IS 302-2-30:2007 &IS:302-1:2008 (Mechanical Strength) |
- |
|
|
|
Cl.22 of IS 302-2-30:2007 &IS:302-1:2008 (Construction) |
- |
|
|
|
Cl.22 of IS 302-2-30:2007 &IS:302-1:2008 (Construction) |
- |
|
|
|
Cl.22 of IS 302-2-30:2007 &IS:302-1:2008 (Construction) |
- |
|
|
|
Cl.24 of IS 302-2-30:2007 &IS:302-1:2008 (Component) |
- |
|
|
|
Cl.22 of IS 302-2-30:2007 &IS:302-1:2008 (Construction) |
- |
|
|
|
Cl.22 of IS 302-2-30:2007 &IS:302-1:2008 (Construction) |
- |
|
|
|
Cl.22 of IS 302-2-30:2007 &IS:302-1:2008 (Construction) |
- |
|
|
|
Cl.22 of IS 302-2-30:2007 &IS:302-1:2008 (Construction) |
- |
|
|
|
Cl.22 of IS 302-2-30:2007 &IS:302-1:2008 (Construction) |
- |
|
|
|
Cl.22 of IS 302-2-30:2007 &IS:302-1:2008 (Construction) |
- |
|
|
|
Cl.22 of IS 302-2-30:2007 &IS:302-1:2008 (Construction) |
- |
|
|
|
Cl.22 of IS 302-2-30:2007 &IS:302-1:2008 (Construction) |
- |
|
|
|
Cl.22 of IS 302-2-30:2007 &IS:302-1:2008 (Construction) |
- |
|
|
|
Cl.22 of IS 302-2-30:2007 &IS:302-1:2008 (Construction) |
- |
|
|
|
Cl.23 of IS 302-2-30:2007 &IS:302-1:2008 (Internal Wiring) |
- |
|
|
|
Cl.23 of IS 302-2-30:2007 &IS:302-1:2008 (Internal Wiring) |
- |
|
|
|
Cl.23 of IS 302-2-30:2007 &IS:302-1:2008 (Internal Wiring) |
- |
|
|
|
Cl.23 of IS 302-2-30:2007 &IS:302-1:2008 (Internal Wiring) |
- |
|
|
|
Cl.23 of IS 302-2-30:2007 &IS:302-1:2008 (Internal Wiring) |
- |
|
|
|
Cl.24 of IS 302-2-30:2007 &IS:302-1:2008 (Component) |
- |
|
|
|
Cl.24 of IS 302-2-30:2007 &IS:302-1:2008 (Component) |
- |
|
|
|
Cl.24 of IS 302-2-30:2007 &IS:302-1:2008 (Component) |
- |
|
|
|
Cl.24 of IS 302-2-30:2007 &IS:302-1:2008 (Component) |
- |
|
|
|
Cl.24 of IS 302-2-30:2007 &IS:302-1:2008 (Component) |
- |
|
|
|
|
Complete
|
|
- |
Excluding Performance test |
131 |
IS 368 (2014) |
Electric immersion water heaters - Specification (Fifth Revision) |
- |
-
|
- View breakup
"For 1 kW & 1.5 kW: Rs.12150.00
For 2 kW and 3 kW: Rs.13050.00
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
Cl.6 of IS 302-‐2-‐201:2008 (Classification) |
- |
|
|
|
Cl.7 of IS 302-2-201:2008 (Marking and Instruction ) |
- |
|
|
|
Cl.7 of IS 302-2-201:2008 (Marking and Instruction ) |
- |
|
|
|
Cl.7 of IS 302-2-201:2008 (Marking and Instruction ) |
- |
|
|
|
Cl.7 of IS 302-2-201:2008 (Marking and Instruction ) |
- |
|
|
|
Cl.7 of IS 302-2-201:2008 (Marking and Instruction ) |
- |
|
|
|
Cl.7 of IS 302-2-201:2008 (Marking and Instruction ) |
- |
|
|
|
Cl.7 of IS 302-2-201:2008 (Marking and Instruction ) |
- |
|
|
|
Cl.7 of IS 302-2-201:2008 (Marking and Instruction ) |
- |
|
|
|
Cl.7 of IS 302-2-201:2008 (Marking and Instruction ) |
- |
|
|
|
Cl.7 of IS 302-2-201:2008 (Marking and Instruction ) |
- |
|
|
|
Cl.7 of IS 302-2-201:2008 (Marking and Instruction ) |
- |
|
|
|
Cl.7 of IS 302-2-201:2008 (Marking and Instruction ) |
- |
|
|
|
Cl.7 of IS 302-2-201:2008 (Marking and Instruction ) |
- |
|
|
|
Cl.7 of IS 302-2-201:2008 (Marking and Instruction ) |
- |
|
|
|
Cl.7 of IS 302-2-201:2008 (Marking and Instruction ) |
- |
|
|
|
Cl.7 of IS 302-2-201:2008 (Marking and Instruction ) |
- |
|
|
|
Cl.7 of IS 302-2-201:2008 (Marking and Instruction ) |
- |
|
|
|
Cl.7 of IS 302-2-201:2008 (Marking and Instruction ) |
- |
|
|
|
Cl.7 of IS 302-2-201:2008 (Marking and Instruction ) |
- |
|
|
|
Cl.8 of IS 302‐2-201: 2008 (Protection Against Access to Live Parts) |
- |
|
|
|
Cl.10 of IS 302‐2‐201:2008 (Power Input and Current ) |
- |
|
|
|
Cl.11 of IS 302-2201: 2008 (Heating) |
- |
|
|
|
Cl.11 of IS 302-2201: 2008 (Heating) |
- |
|
|
|
Cl.11 of IS 302-2201: 2008 (Heating) |
- |
|
|
|
Cl.11 of IS 302-2201: 2008 (Heating) |
- |
|
|
|
Cl.11 of IS 302-2201: 2008 (Heating) |
- |
|
|
|
Cl.11 of IS 302-2201: 2008 (Heating) |
- |
|
|
|
Cl.11 of IS 302-2201: 2008 (Heating) |
- |
|
|
|
Cl.11 of IS 302-2201: 2008 (Heating) |
- |
|
|
|
Cl.11 of IS 302-2201: 2008 (Heating) |
- |
|
|
|
Cl.11 of IS 302-2201: 2008 (Heating) |
- |
|
|
|
Cl.11 of IS 302-2201: 2008 (Heating) |
- |
|
|
|
Cl.13 of IS 302-2-201: 2008 (Leakage Current & Electric Strength at Operating Temperature) |
- |
|
|
|
Cl.13 of IS 302-2-201: 2009 (Leakage Current & Electric Strength at Operating Temperature) |
- |
|
|
|
Cl.15 of IS 302-2-201:2008 (Moisture Resistance ) |
- |
|
|
|
Cl.15 of IS 302-2-201:2008 (Moisture Resistance ) |
- |
|
|
|
Cl.16 of IS 302-2-201:2008 (Leakage Current & Electric Strength) |
- |
|
|
|
Cl.16 of IS 302-2-201:2008 (Leakage Current & Electric Strength) |
- |
|
|
|
Cl.18 of IS 368:2014 (Endurance) |
- |
|
|
|
Cl.19 of IS 302‐2-201: 2008 (Abnormal Operation ) |
- |
|
|
|
Cl.19 of IS 302‐2-201: 2008 (Abnormal Operation ) |
- |
|
|
|
Cl.19 of IS 302‐2-201: 2008 (Abnormal Operation ) |
- |
|
|
|
Cl.19 of IS 302‐2-201: 2008 (Abnormal Operation ) |
- |
|
|
|
Cl.20 of IS 302-2-201: 2008 (Stability & Mechanical Hazards) |
- |
|
|
|
Cl.21 of IS 302-2-201: 2008 (Mechanical Strength ) |
- |
|
|
|
Cl.21 of IS 302-2-201: 2008 (Mechanical Strength ) |
- |
|
|
|
Cl.22 of IS 302-2-201: 2008 (Construction) |
- |
|
|
|
Cl.22 of IS 302-2-201: 2008 (Construction) |
- |
|
|
|
Cl.22 of IS 302-2-201: 2008 (Construction) |
- |
|
|
|
Cl.22 of IS 302-2-201: 2008 (Construction) |
- |
|
|
|
Cl.23 of 302-2-201:2008 (Internal Wiring ) |
- |
|
|
|
Cl.23 of 302-2-201:2008 (Internal Wiring ) |
- |
|
|
|
Cl.23 of 302-2-201:2008 (Internal Wiring ) |
- |
|
|
|
Cl.23 of 302-2-201:2008 (Internal Wiring ) |
- |
|
|
|
Cl.23 of 302-2-201:2008 (Internal Wiring ) |
- |
|
|
|
Cl.23 of 302-2-201:2008 (Internal Wiring ) |
- |
|
|
|
Cl.23 of 302-2-201:2008 (Internal Wiring ) |
- |
|
|
|
Cl.23 of 302-2-201:2008 (Internal Wiring ) |
- |
|
|
|
Cl.24 of IS 302-2-201: 2008 (Component) |
- |
|
|
|
Cl.24 of IS 302-2-201: 2008 (Component) |
- |
|
|
|
Cl.24 of IS 302-2-201: 2008 (Component) |
- |
|
|
|
Cl.24 of IS 302-2-201: 2008 (Component) |
- |
|
|
|
Cl.24 of IS 302-2-201: 2008 (Component) |
- |
|
|
|
Cl.24 of IS 302-2-201: 2008 (Component) |
- |
|
|
|
Cl.24 of IS 302-2-201: 2008 (Component) |
- |
|
|
|
Cl.24 of IS 302-2-201: 2008 (Component) |
- |
|
|
|
Cl.24 of IS 302-2-201: 2008 (Component) |
- |
|
|
|
Cl.25 of IS 302-2-201: 2008 (Supply Connection and External Flexible Cords) |
- |
|
|
|
Cl.25 of IS 302-2-201: 2008 (Supply Connection and External Flexible Cords) |
- |
|
|
|
Cl.25 of IS 302-2-201: 2008 (Supply Connection and External Flexible Cords) |
- |
|
|
|
Cl.25 of IS 302-2-201: 2008 (Supply Connection and External Flexible Cords) |
- |
|
|
|
Cl.25 of IS 302-2-201: 2008 (Supply Connection and External Flexible Cords) |
- |
|
|
|
Cl.25 of IS 302-2-201: 2008 (Supply Connection and External Flexible Cords) |
- |
|
|
|
Cl.25 of IS 302-2-201: 2008 (Supply Connection and External Flexible Cords) |
- |
|
|
|
Cl.25 of IS 302-2-201: 2008 (Supply Connection and External Flexible Cords) |
- |
|
|
|
Cl.25 of IS 302-2-201: 2008 (Supply Connection and External Flexible Cords) |
- |
|
|
|
Cl.25 of IS 302-2-201: 2008 (Supply Connection and External Flexible Cords) |
- |
|
|
|
Cl.25 of IS 302-2-201: 2008 (Supply Connection and External Flexible Cords) |
- |
|
|
|
Cl.25 of IS 302-2-201: 2008 (Supply Connection and External Flexible Cords) |
- |
|
|
|
Cl.25 of IS 302-2-201: 2008 (Supply Connection and External Flexible Cords) |
- |
|
|
|
Cl.25 of IS 302-2-201: 2008 (Supply Connection and External Flexible Cords) |
- |
|
|
|
Cl.25 of IS 302-2-201: 2008 (Supply Connection and External Flexible Cords) |
- |
|
|
|
Cl.25 of IS 302-2-201: 2008 (Supply Connection and External Flexible Cords) |
- |
|
|
|
Cl.25 of IS 302-2-201: 2008 (Supply Connection and External Flexible Cords) |
- |
|
|
|
Cl.26 of IS 302-2-201: 2008 (Terminals for External Conductors) |
- |
|
|
|
Cl.27 of IS 302-2-201: 2008 (Provision for Earthing ) |
- |
|
|
|
Cl.27 of IS 302-2-201: 2008 (Provision for Earthing ) |
- |
|
|
|
Cl.27 of IS 302-2-201: 2008 (Provision for Earthing ) |
- |
|
|
|
Cl.27 of IS 302-2-201: 2008 (Provision for Earthing ) |
- |
|
|
|
Cl.27 of IS 302-2-201: 2008 (Provision for Earthing ) |
- |
|
|
|
Cl.27 of IS 302-2-201: 2008 (Provision for Earthing ) |
- |
|
|
|
Cl.28 of IS 302-2-201: 2008 (Screws & Connections ) |
- |
|
|
|
Cl.29 of IS 302-2‐201:2008 (Clearances, Creepage Distances and Solid Insulation ) |
- |
|
|
|
Cl.29 of IS 302-2‐201:2008 (Clearances, Creepage Distances and Solid Insulation ) |
- |
|
|
|
Cl.30 of IS 302-2‐201:2008 (Resistance to Heat and Fire ) |
- |
|
|
|
Cl.30 of IS 302-2‐201:2008 (Resistance to Heat and Fire ) |
- |
|
|
|
Cl.31 of IS 302-2-201:2008 (Resistance of Rusting ) |
- |
|
|
|
Cl.32 of IS 302-2-201:2008 (Radiation, Toxicity and Similar Hazards) |
- |
|
|
|
|
Partial
|
|
- |
Excluding test facility not availble for rating above 3kW |
132 |
IS 302 : Part 2 : Sec 202 (1992) |
Safety of household and similar electrical appliances: Part 2 particular requirements: Sec 202 electric stoves |
- |
-
|
Rs 2275/- View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
6 (Classification- IS 302-1 ) |
- |
|
|
|
6 (Classification- IS 302-1) |
- |
|
|
|
7.1 (Marking- IS 302-1) |
- |
|
|
|
7.1 (Marking- IS 302-1) |
- |
|
|
|
7.1 (Marking- IS 302-1) |
- |
|
|
|
7.1 (Marking- IS 302-1) |
- |
|
|
|
7.1 (Marking- IS 302-1) |
- |
|
|
|
7.1 (Marking- IS 302-1) |
- |
|
|
|
7.1 (Marking- IS 302-1) |
- |
|
|
|
7.1 (Marking- IS 302-1) |
- |
|
|
|
7.1 (Marking- IS 302-1) |
- |
|
|
|
7.3 (Marking- IS 302-1) |
- |
|
|
|
7.4 (Marking- IS 302-1) |
- |
|
|
|
7.6 (Marking- IS 302-1) |
- |
|
|
|
7.11 (Marking- IS 302-1) |
- |
|
|
|
7.12 (Marking- IS 302-1) |
- |
|
|
|
7.13 (Marking- IS 302-1) |
- |
|
|
|
7.14 (Marking- IS 302-1) |
- |
|
|
|
7.15 (Marking- IS 302-1) |
- |
|
|
|
7.101 (Marking) |
- |
|
|
|
8 ( Protection Against Electric Shock, IS 302-1) |
- |
|
|
|
10 (Power Input and Current, IS 302-1) |
- |
|
|
|
11 (Heating, IS 302-1) |
- |
|
|
|
11 (Heating, IS 302-1) |
- |
|
|
|
11 (Heating, IS 302-1) |
- |
|
|
|
11 (Heating, IS 302-1) |
- |
|
|
|
11 (Heating, IS 302-1) |
- |
|
|
|
11 (Heating, IS 302-1) |
- |
|
|
|
11 (Heating, IS 302-1) |
- |
|
|
|
13 (Electrical Insulation and Leakage Current at Operating Temperature: Leakage current, IS 302-1) |
- |
|
|
|
13 (Electrical Insulation and Leakage Current at Operating Temperature: High Voltage, IS 302-1) |
- |
|
|
|
15.1 (Moisture Resistance, IS 302-1) |
- |
|
|
|
15.3 (Moisture Resistance, IS 302-1) |
- |
|
|
|
16 (Electrical Insulation and Leakage Current at Operating Temperature: Leakage current, IS 302-1) |
- |
|
|
|
16 (Electrical Insulation and Leakage Current at Operating Temperature: High Voltage, IS 302-1) |
- |
|
|
|
19.2 (Abnormal Operation, IS 302-1) |
- |
|
|
|
19.2 (Abnormal Operation, IS 302-1) |
- |
|
|
|
19.3 (Abnormal Operation, IS 302-1) |
- |
|
|
|
19.3 (Abnormal Operation, IS 302-1) |
- |
|
|
|
20.1 (Stability & Mechanical Hazards, IS 302-1) |
- |
|
|
|
21.1 (Mechanical Strength, IS 302-1 & IS 302-2-202) |
- |
|
|
|
22 (Construction, IS 302-1) |
- |
|
|
|
22.101 (Construction) |
- |
|
|
|
22.102 (Construction) |
- |
|
|
|
22.103 (Construction) |
- |
|
|
|
22.104 (Construction) |
- |
|
|
|
22.105 (Construction) |
- |
|
|
|
22.105.1 (Construction) |
- |
|
|
|
22.105.2 (Construction) |
- |
|
|
|
22.106 (Construction) |
- |
|
|
|
22.107 (Construction) |
- |
|
|
|
11.107.1 (Construction) |
- |
|
|
|
23.1 (Internal Wiring, IS 302-1) |
- |
|
|
|
23.2 (Internal Wiring, IS 302-1) |
- |
|
|
|
23.8 (Internal Wiring, IS 302-1) |
- |
|
|
|
23.9 (Internal Wiring, IS 302-1) |
- |
|
|
|
23.10 (Internal Wiring, IS 302-1) |
- |
|
|
|
24.1 (Components, IS 302-1) |
- |
|
|
|
24.2 (Components, IS 302-1) |
- |
|
|
|
24.101 (Components) |
- |
|
|
|
25.1 (Supply Connection and External Flexible Cords, IS 302-1) |
- |
|
|
|
25.4 (Supply Connection and External Flexible Cords) |
- |
|
|
|
25.5 (Supply Connection and External Flexible Cords, IS 302-1) |
- |
|
|
|
25.6 (Supply Connection and External Flexible Cords, IS 302-1) |
- |
|
|
|
25.8 (Supply Connection and External Flexible Cords, IS 302-1) |
- |
|
|
|
26.9 (Supply Connection and External Flexible Cords, IS 302-1) |
- |
|
|
|
25.1 (Supply Connection and External Flexible Cords, IS 302-1) |
- |
|
|
|
25.11 (Supply Connection and External Flexible Cords, IS 302-1) |
- |
|
|
|
25.12 (Supply Connection and External Flexible Cords, IS 302-1) |
- |
|
|
|
25.15 (Supply Connection and External Flexible Cords, IS 302-1) |
- |
|
|
|
25.16 (Supply Connection and External Flexible Cords, IS 302-1) |
- |
|
|
|
25.17 (Supply Connection and External Flexible Cords, IS 302-1) |
- |
|
|
|
25.18 (Supply Connection and External Flexible Cords, IS 302-1) |
- |
|
|
|
25.19 (Supply Connection and External Flexible Cords, IS 302-1) |
- |
|
|
|
25.2 (Supply Connection and External Flexible Cords, IS 302-1) |
- |
|
|
|
25.21 (Supply Connection and External Flexible Cords, IS 302-1) |
- |
|
|
|
25.22 (Supply Connection and External Flexible Cords, IS 302-1) |
- |
|
|
|
26 (Terminals for External Conductors, IS 302-1) |
- |
|
|
|
27.1 (Provision for Earthing, IS 302-1) |
- |
|
|
|
27.2 (Provision for Earthing, IS 302-1) |
- |
|
|
|
27.3 (Provision for Earthing, IS 302-1) |
- |
|
|
|
27.4 (Provision for Earthing, IS 302-1) |
- |
|
|
|
27.5 (Provision for Earthing, IS 302-1) |
- |
|
|
|
28 (Screws & Connections, IS 302-1) |
- |
|
|
|
29.1 (Clearances, Creepage distances and Solid Insulation, IS 302-1) |
- |
|
|
|
29.2 (Clearances, Creepage distances and Solid Insulation, IS 302-1) |
- |
|
|
|
30.1 (Resistance to Heat, Fire & Tracking, IS 302-1) |
- |
|
|
|
30.2 (Resistance to Heat, Fire & Tracking, IS 302-1) |
- |
|
|
|
31 (Resistance of Rusting, IS 302-1) |
- |
|
|
|
|
Partial
|
|
- |
Except 1. Cl. 14 Transient Overvoltage Test IS 302-1:2008 2. Cl. 19.11 and Cl. 19.12 abnormal test (for Electronic circuit) 3. Cl.24 Component Test IS 302-1:2008 |
133 |
IS 302 : Part 2 : Sec 201 (2008) |
Safety of household and similar electrical appliances: Part 2 particular requirements: Sec 201 electric immersion water heaters (First Revision) |
- |
-
|
Rs 6900/ View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
Cl.6 of IS 302-‐2-‐201:2008 (Classification) |
- |
|
|
|
Cl.7 of IS 302-2-201:2008 (Marking and Instruction ) |
- |
|
|
|
Cl.7 of IS 302-2-201:2008 (Marking and Instruction ) |
- |
|
|
|
Cl.7 of IS 302-2-201:2008 (Marking and Instruction ) |
- |
|
|
|
Cl.7 of IS 302-2-201:2008 (Marking and Instruction ) |
- |
|
|
|
Cl.7 of IS 302-2-201:2008 (Marking and Instruction ) |
- |
|
|
|
Cl.7 of IS 302-2-201:2008 (Marking and Instruction ) |
- |
|
|
|
Cl.7 of IS 302-2-201:2008 (Marking and Instruction ) |
- |
|
|
|
Cl.7 of IS 302-2-201:2008 (Marking and Instruction ) |
- |
|
|
|
Cl.7 of IS 302-2-201:2008 (Marking and Instruction ) |
- |
|
|
|
Cl.7 of IS 302-2-201:2008 (Marking and Instruction ) |
- |
|
|
|
Cl.7 of IS 302-2-201:2008 (Marking and Instruction ) |
- |
|
|
|
Cl.7 of IS 302-2-201:2008 (Marking and Instruction ) |
- |
|
|
|
Cl.7 of IS 302-2-201:2008 (Marking and Instruction ) |
- |
|
|
|
Cl.7 of IS 302-2-201:2008 (Marking and Instruction ) |
- |
|
|
|
Cl.7 of IS 302-2-201:2008 (Marking and Instruction ) |
- |
|
|
|
Cl.7 of IS 302-2-201:2008 (Marking and Instruction ) |
- |
|
|
|
Cl.7 of IS 302-2-201:2008 (Marking and Instruction ) |
- |
|
|
|
Cl.7 of IS 302-2-201:2008 (Marking and Instruction ) |
- |
|
|
|
Cl.7 of IS 302-2-201:2008 (Marking and Instruction ) |
- |
|
|
|
Cl.7 of IS 302-2-201:2008 (Marking and Instruction ) |
- |
|
|
|
Cl.8 of IS 302‐2-201: 2008 (Protection Against Access to Live Parts) |
- |
|
|
|
Cl.10 of IS 302‐2‐201:2008 (Power Input and Current ) |
- |
|
|
|
Cl.11 of IS 302-2201: 2008 (Heating) |
- |
|
|
|
Cl.11 of IS 302-2201: 2008 (Heating) |
- |
|
|
|
Cl.11 of IS 302-2201: 2008 (Heating) |
- |
|
|
|
Cl.11 of IS 302-2201: 2008 (Heating) |
- |
|
|
|
Cl.11 of IS 302-2201: 2008 (Heating) |
- |
|
|
|
Cl.11 of IS 302-2201: 2008 (Heating) |
- |
|
|
|
Cl.11 of IS 302-2201: 2008 (Heating) |
- |
|
|
|
Cl.11 of IS 302-2201: 2008 (Heating) |
- |
|
|
|
Cl.11 of IS 302-2201: 2008 (Heating) |
- |
|
|
|
Cl.11 of IS 302-2201: 2008 (Heating) |
- |
|
|
|
Cl.11 of IS 302-2201: 2008 (Heating) |
- |
|
|
|
Cl.13 of IS 302-2-201: 2008 (Leakage Current & Electric Strength at Operating Temperature) |
- |
|
|
|
Cl.15 of IS 302-2-201:2008 (Moisture Resistance ) |
- |
|
|
|
Cl.15 of IS 302-2-201:2008 (Moisture Resistance ) |
- |
|
|
|
Cl.16 of IS 302-2-201:2008 (Leakage Current & Electric Strength) |
- |
|
|
|
Cl.16 of IS 302-2-201:2008 (Leakage Current & Electric Strength) |
- |
|
|
|
Cl.19 of IS 302‐2-201: 2008 (Abnormal Operation ) |
- |
|
|
|
Cl.19 of IS 302‐2-201: 2008 (Abnormal Operation ) |
- |
|
|
|
Cl.19 of IS 302‐2-201: 2008 (Abnormal Operation ) |
- |
|
|
|
Cl.19 of IS 302‐2-201: 2008 (Abnormal Operation ) |
- |
|
|
|
Cl.20 of IS 302-2-201: 2008 (Stability & Mechanical Hazards) |
- |
|
|
|
Cl.21 of IS 302-2-201: 2008 (Mechanical Strength ) |
- |
|
|
|
Cl.21 of IS 302-2-201: 2008 (Mechanical Strength ) |
- |
|
|
|
Cl.21 of IS 302-2-201: 2008 (Mechanical Strength ) |
- |
|
|
|
Cl.22 of IS 302-2-201: 2008 (Construction) |
- |
|
|
|
Cl.23 of 302-2-201:2008 (Internal Wiring ) |
- |
|
|
|
Cl.23 of 302-2-201:2008 (Internal Wiring ) |
- |
|
|
|
Cl.23 of 302-2-201:2008 (Internal Wiring ) |
- |
|
|
|
Cl.23 of 302-2-201:2008 (Internal Wiring ) |
- |
|
|
|
Cl.23 of 302-2-201:2008 (Internal Wiring ) |
- |
|
|
|
Cl.23 of 302-2-201:2008 (Internal Wiring ) |
- |
|
|
|
Cl.23 of 302-2-201:2008 (Internal Wiring ) |
- |
|
|
|
Cl.23 of 302-2-201:2008 (Internal Wiring ) |
- |
|
|
|
Cl.23 of 302-2-201:2008 (Internal Wiring ) |
- |
|
|
|
Cl.24 of IS 302-2-201: 2008 (Component) |
- |
|
|
|
Cl.24 of IS 302-2-201: 2008 (Component) |
- |
|
|
|
Cl.24 of IS 302-2-201: 2008 (Component) |
- |
|
|
|
Cl.24 of IS 302-2-201: 2008 (Component) |
- |
|
|
|
Cl.24 of IS 302-2-201: 2008 (Component) |
- |
|
|
|
Cl.24 of IS 302-2-201: 2008 (Component) |
- |
|
|
|
Cl.24 of IS 302-2-201: 2008 (Component) |
- |
|
|
|
Cl.24 of IS 302-2-201: 2008 (Component) |
- |
|
|
|
Cl.25 of IS 302-2-201: 2008 (Supply Connection and External Flexible Cords) |
- |
|
|
|
Cl.25 of IS 302-2-201: 2008 (Supply Connection and External Flexible Cords) |
- |
|
|
|
Cl.25 of IS 302-2-201: 2008 (Supply Connection and External Flexible Cords) |
- |
|
|
|
Cl.25 of IS 302-2-201: 2008 (Supply Connection and External Flexible Cords) |
- |
|
|
|
Cl.25 of IS 302-2-201: 2008 (Supply Connection and External Flexible Cords) |
- |
|
|
|
Cl.25 of IS 302-2-201: 2008 (Supply Connection and External Flexible Cords) |
- |
|
|
|
Cl.25 of IS 302-2-201: 2008 (Supply Connection and External Flexible Cords) |
- |
|
|
|
Cl.25 of IS 302-2-201: 2008 (Supply Connection and External Flexible Cords) |
- |
|
|
|
Cl.25 of IS 302-2-201: 2008 (Supply Connection and External Flexible Cords) |
- |
|
|
|
Cl.25 of IS 302-2-201: 2008 (Supply Connection and External Flexible Cords) |
- |
|
|
|
Cl.25 of IS 302-2-201: 2008 (Supply Connection and External Flexible Cords) |
- |
|
|
|
Cl.25 of IS 302-2-201: 2008 (Supply Connection and External Flexible Cords) |
- |
|
|
|
Cl.25 of IS 302-2-201: 2008 (Supply Connection and External Flexible Cords) |
- |
|
|
|
Cl.25 of IS 302-2-201: 2008 (Supply Connection and External Flexible Cords) |
- |
|
|
|
Cl.25 of IS 302-2-201: 2008 (Supply Connection and External Flexible Cords) |
- |
|
|
|
Cl.25 of IS 302-2-201: 2008 (Supply Connection and External Flexible Cords) |
- |
|
|
|
Cl.25 of IS 302-2-201: 2008 (Supply Connection and External Flexible Cords) |
- |
|
|
|
Cl.25 of IS 302-2-201: 2008 (Supply Connection and External Flexible Cords) |
- |
|
|
|
Cl.25 of IS 302-2-201: 2008 (Supply Connection and External Flexible Cords) |
- |
|
|
|
Cl.25 of IS 302-2-201: 2008 (Supply Connection and External Flexible Cords) |
- |
|
|
|
Cl.26 of IS 302-2-201: 2008 (Terminals for External Conductors) |
- |
|
|
|
Cl.27 of IS 302-2-201: 2008 (Provision for Earthing ) |
- |
|
|
|
Cl.27 of IS 302-2-201: 2008 (Provision for Earthing ) |
- |
|
|
|
Cl.27 of IS 302-2-201: 2008 (Provision for Earthing ) |
- |
|
|
|
Cl.27 of IS 302-2-201: 2008 (Provision for Earthing ) |
- |
|
|
|
Cl.27 of IS 302-2-201: 2008 (Provision for Earthing ) |
- |
|
|
|
Cl.27 of IS 302-2-201: 2008 (Provision for Earthing ) |
- |
|
|
|
Cl.28 of IS 302-2-201: 2008 (Screws & Connections ) |
- |
|
|
|
Cl.29 of IS 302-2‐201:2008 (Clearances, Creepage Distances and Solid Insulation ) |
- |
|
|
|
Cl.30 of IS 302-2‐201:2008 (Resistance to Heat and Fire ) |
- |
|
|
|
Cl.31 of IS 302-2-201:2008 (Resistance of Rusting ) |
- |
|
|
|
Cl.32 of IS 302-2-201:2008 (Radiation, Toxicity and Similar Hazards) |
- |
|
|
|
|
Partial
|
|
- |
Excluding test facility not availble for rating above 3kW |
134 |
IS 302 : Part 2 : Sec 30 (2007) |
Safety of household and similar electrical appliances: Part 2 particular requirements: Sec 30 room heaters (First Revision) |
- |
-
|
- View breakup
Rs.9950/- up to and including 1 Kw Rs. 10900/- up to and including 2 Kw
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
Cl.6 (Classification) |
- |
|
|
|
Cl.6 (Classification) |
- |
|
|
|
Cl.7 & IS:302-1:2008 (Marking and Instructions) |
- |
|
|
|
Cl.7 & IS:302-1:2008 (Marking and Instructions) |
- |
|
|
|
Cl.7 & IS:302-1:2008 (Marking and Instructions) |
- |
|
|
|
Cl.7 & IS:302-1:2008 (Marking and Instructions) |
- |
|
|
|
Cl.7 & IS:302-1:2008 (Marking and Instructions) |
- |
|
|
|
Cl.7 & IS:302-1:2008 (Marking and Instructions) |
- |
|
|
|
Cl.7 & IS:302-1:2008 (Marking and Instructions) |
- |
|
|
|
Cl.7 & IS:302-1:2008 (Marking and Instructions) |
- |
|
|
|
Cl.7 & IS:302-1:2008 (Marking and Instructions) |
- |
|
|
|
Cl.7 (Marking and Instructions) |
- |
|
|
|
Cl.7 (Marking and Instructions) |
- |
|
|
|
Cl.7 (Marking and Instructions) |
- |
|
|
|
Cl.7.3 (Marking and Instructions) |
- |
|
|
|
Cl.7.3 (Marking and Instructions) |
- |
|
|
|
Cl.7.3 (Marking and Instructions) |
- |
|
|
|
Cl.7.4 (Marking and Instructions) |
- |
|
|
|
Cl.7.5 (Marking and Instructions) |
- |
|
|
|
Cl.7.6 & IS:302-1:2008 (Marking and Instructions) |
- |
|
|
|
Cl.7.8 of IS :302-1:2008 (Marking and Instructions) |
- |
|
|
|
Cl.7.9 of IS :302-1:2008 (Marking and Instructions) |
- |
|
|
|
Cl.7.10 of IS :302-1:2008 (Marking and Instructions) |
- |
|
|
|
Cl.7.11 of IS :302-1:2008 (Marking and Instructions) |
- |
|
|
|
Cl.7.12 & IS:302-1:2008 (Marking and Instructions) |
- |
|
|
|
Cl.7.12 & IS:302-1:2008 (Marking and Instructions) |
- |
|
|
|
Cl.7.12 & IS:302-1:2008 (Marking and Instructions) |
- |
|
|
|
Cl.7.12 & IS:302-1:2008 (Marking and Instructions) |
- |
|
|
|
Cl.7.12 & IS:302-1:2008 (Marking and Instructions) |
- |
|
|
|
Cl.7.12 & IS:302-1:2008 (Marking and Instructions) |
- |
|
|
|
Cl.7.12 & IS:302-1:2008 (Marking and Instructions) |
- |
|
|
|
Cl.7.12 & IS:302-1:2008 (Marking and Instructions) |
- |
|
|
|
Cl.7.12 & IS:302-1:2008 (Marking and Instructions) |
- |
|
|
|
Cl.7.12 & IS:302-1:2008 (Marking and Instructions) |
- |
|
|
|
Cl.7.12 & IS:302-1:2008 (Marking and Instructions) |
- |
|
|
|
Cl.7.12 & IS:302-1:2008 (Marking and Instructions) |
- |
|
|
|
Cl.7.12.1 & IS:302-1:2008 (Marking and Instructions) |
- |
|
|
|
Cl.7.12.1 & IS:302-1:2008 (Marking and Instructions) |
- |
|
|
|
Cl.7.12.1 & IS:302-1:2008 (Marking and Instructions) |
- |
|
|
|
Cl.7.12.1 & IS:302-1:2008 (Marking and Instructions) |
- |
|
|
|
Cl.7.12.1 & IS:302-1:2008 (Marking and Instructions) |
- |
|
|
|
Cl.7.12.1 & IS:302-1:2008 (Marking and Instructions) |
- |
|
|
|
Cl.7.12.1 & IS:302-1:2008 (Marking and Instructions) |
- |
|
|
|
Cl.7.12.1 & IS:302-1:2008 (Marking and Instructions) |
- |
|
|
|
Cl.7.12.1 & IS:302-1:2008 (Marking and Instructions) |
- |
|
|
|
Cl.7.12.1 & IS:302-1:2008 (Marking and Instructions) |
- |
|
|
|
Cl.7.12.1 & IS:302-1:2009 (Marking and Instructions) |
- |
|
|
|
Cl.7.13 of IS 302-1:2008 (Marking and Instructions) |
- |
|
|
|
Cl.7.14 of IS302-1:2008 (Marking and Instructions) |
- |
|
|
|
Cl.7.14 (Marking and Instructions) |
- |
|
|
|
Cl.7.14 (Marking and Instructions) |
- |
|
|
|
Cl.7.15 of IS 302-1:2008 (Marking and Instructions) |
- |
|
|
|
Cl.7.15 of IS 302-1:2008 (Marking and Instructions) |
- |
|
|
|
Cl.7.15 of IS 302-1:2008 (Marking and Instructions) |
- |
|
|
|
Cl.7.15 of IS 302-1:2008 (Marking and Instructions) |
- |
|
|
|
Cl.8 & IS:302-1:2008 (Protection Against Access to Live Parts) |
- |
|
|
|
Cl.10 & IS:302-1:2008 (Power Input and Current) |
- |
|
|
|
Cl.11 & IS:302-1:2008 (Heating) |
- |
|
|
|
Cl.11 & IS:302-1:2008 (Heating) |
- |
|
|
|
Cl.11 & IS:302-1:2008 (Heating) |
- |
|
|
|
Cl.11 & IS:302-1:2008 (Heating) |
- |
|
|
|
Cl.11 & IS:302-1:2008 (Heating) |
- |
|
|
|
Cl.11 & IS:302-1:2008 (Heating) |
- |
|
|
|
Cl.11 & IS:302-1:2008 (Heating) |
- |
|
|
|
Cl.11 & IS:302-1:2008 (Heating) |
- |
|
|
|
Cl.11 & IS:302-1:2008 (Heating) |
- |
|
|
|
Cl.11 & IS:302-1:2008 (Heating) |
- |
|
|
|
Cl.11 & IS:302-1:2008 (Heating) |
- |
|
|
|
Cl.11 & IS:302-1:2008 (Heating) |
- |
|
|
|
Cl.11 & IS:302-1:2008 (Heating) |
- |
|
|
|
Cl.11.8 (Heating) |
- |
|
|
|
Cl.11.8 (Heating) |
- |
|
|
|
Cl.11.8 (Heating) |
- |
|
|
|
Cl.13 & IS:302-1:2008 (Leakage Current & Electric Strength at operating temp. ) |
- |
|
|
|
Cl.13 & IS:302-1:2008 (Leakage Current & Electric Strength at operating temp. ) |
- |
|
|
|
Cl.15 & IS: 302-1:2008 (Moisture Resistance
) |
- |
|
|
|
Cl.15.3 of IS 302-1:200 (Moisture Resistance
) |
- |
|
|
|
Cl.16 & IS:302-1:2008 (Leakage Current & Electric Strength ) |
- |
|
|
|
Cl.16 & IS:302-1:2008 (Leakage Current & Electric Strength ) |
- |
|
|
|
Cl.19 & IS:302-1:2008 (Abnormal Operation.) |
- |
|
|
|
Cl.19 & IS:302-1:2008 (Abnormal Operation.) |
- |
|
|
|
Cl.19 & IS:302-1:2008 (Abnormal Operation.) |
- |
|
|
|
Cl.19 & IS:302-1:2008 (Abnormal Operation.) |
- |
|
|
|
Cl.19.101 (Abnormal Operation.) |
- |
|
|
|
Cl.19.102 (Abnormal Operation.) |
- |
|
|
|
Cl.19.103 (Abnormal Operation.) |
- |
|
|
|
Cl.19.104 (Abnormal Operation.) |
- |
|
|
|
Cl.19.105 (Abnormal Operation.) |
- |
|
|
|
Cl.19.106 (Abnormal Operation.) |
- |
|
|
|
Table 8 of IS 302-1:2008 (Abnormal Operation.) |
- |
|
|
|
Cl.19.107 (Abnormal Operation.) |
- |
|
|
|
Cl.19.108 (Abnormal Operation.) |
- |
|
|
|
Cl.19.109 (Abnormal Operation.) |
- |
|
|
|
Cl.19.110 (Abnormal Operation.) |
- |
|
|
|
Cl.19.111 (Abnormal Operation.) |
- |
|
|
|
Cl.19.112 (Abnormal Operation.) |
- |
|
|
|
Cl.19.113 (Abnormal Operation.) |
- |
|
|
|
Cl.19.114 (Abnormal Operation.) |
- |
|
|
|
Cl.20 & IS:302-1:2008 (Stability & Mechanical Hazards) |
- |
|
|
|
Cl.21 & IS:302-1:2008) (Mechanical Strength.) |
- |
|
|
|
Cl.21.2 of IS 302-1:2008 (Mechanical Strength.) |
- |
|
|
|
Cl.21.101 (Mechanical Strength.) |
- |
|
|
|
Cl.21.102 (Mechanical Strength.) |
- |
|
|
|
Cl.21.103 (Mechanical Strength.) |
- |
|
|
|
Cl.22.1 of IS 302-1:2008 (Construction) |
- |
|
|
|
Cl.22.5 of IS 302-1:2008 (Construction) |
- |
|
|
|
Cl.22.6 of IS 302-1:2008 (Construction) |
- |
|
|
|
Cl.22.7 of IS 302-1:2008 (Construction) |
- |
|
|
|
Cl.22.8 of IS 302-1:2008 (Construction) |
- |
|
|
|
Cl.22.9 of IS 302-1:2008 (Construction) |
- |
|
|
|
Cl.22.11 (Construction) |
- |
|
|
|
Cl.22.12 of IS 302-1:2008 (Construction) |
- |
|
|
|
Cl.22.13 of IS 302-1:2008 (Construction) |
- |
|
|
|
Cl.22.15 of IS 302-1:2008 (Construction) |
- |
|
|
|
Cl.22.18 of IS 302-1:2008 (Construction) |
- |
|
|
|
Cl.22.20 of IS 302-1:2008 (Construction) |
- |
|
|
|
Cl.22.21 of IS 302-1:2008 (Construction) |
- |
|
|
|
Cl.23 & IS:302-1:2008 (Internal Wiring
) |
- |
|
|
|
Cl.23.4 & Cl.29 of 302-1:2008 (Internal Wiring
) |
- |
|
|
|
Cl.23.5 of 302-1:2008 (Internal Wiring
) |
- |
|
|
|
Cl.23.7 of 302-1:2008 (Internal Wiring
) |
- |
|
|
|
C.23.7 of 302-1:2008 (Internal Wiring
) |
- |
|
|
|
Cl.24.1 of 302-1:2008 (Component) |
- |
|
|
|
Cl.24.1 of 302-1:2008 (Component) |
- |
|
|
|
Cl.24.1.3 (Component) |
- |
|
|
|
Cl.24.1.3 (Component) |
- |
|
|
|
Cl.24.1.3 (Component) |
- |
|
|
|
Cl.24.1.3 (Component) |
- |
|
|
|
C.24.2 of 302-1:2008 (Component) |
- |
|
|
|
Cl.24.10 (Component) |
- |
|
|
|
Cl.24.1 of 302-1:2008 (Component) |
- |
|
|
|
Cl.24.1 of 302-1:2008 (Component) |
- |
|
|
|
Cl.24.1.3 (Component) |
- |
|
|
|
Cl.24.1.3 (Component) |
- |
|
|
|
Cl.24.1.3 (Component) |
- |
|
|
|
Cl.24.1.3 (Component) |
- |
|
|
|
C.24.2 of 302-1:2008 (Component) |
- |
|
|
|
Cl.24.10 (Component) |
- |
|
|
|
Cl.25.1 of 302-1:2008 (Supply Connection and External Flexible Cords ) |
- |
|
|
|
Cl. 25.2 of IS 3021:2008 (Supply Connection and External Flexible Cords ) |
- |
|
|
|
Cl. 25.3 of IS 302-1:2008 (Supply Connection and External Flexible Cords ) |
- |
|
|
|
Cl. 25.4 of IS 302-1:2008 (Supply Connection and External Flexible Cords ) |
- |
|
|
|
Cl.25.5 of 302-1:2008 (Supply Connection and External Flexible Cords ) |
- |
|
|
|
Cl.25.6 of 302-1:2008 (Supply Connection and External Flexible Cords ) |
- |
|
|
|
Cl.25.7. (Supply Connection and External Flexible Cords ) |
- |
|
|
|
Cl.25.8 (Supply Connection and External Flexible Cords ) |
- |
|
|
|
Cl. 25.9 (Supply Connection and External Flexible Cords ) |
- |
|
|
|
Cl.25.10 of 302-1:2008 (Supply Connection and External Flexible Cords ) |
- |
|
|
|
Cl. 25.11 (Supply Connection and External Flexible Cords ) |
- |
|
|
|
Cl. 25.12 (Supply Connection and External Flexible Cords ) |
- |
|
|
|
Cl. 25.13 (Supply Connection and External Flexible Cords ) |
- |
|
|
|
Cl.7.101 (Marking and Instructions) |
- |
|
|
|
Cl.25.14 of IS 302-1:2008 (Supply Connection and External Flexible Cords ) |
- |
|
|
|
Cl.25.15 of IS 302-1:2008 (Supply Connection and External Flexible Cords ) |
- |
|
|
|
Cl.25.17 of IS 302-1:2008 (Supply Connection and External Flexible Cords ) |
- |
|
|
|
Cl.25.18 (Supply Connection and External Flexible Cords ) |
- |
|
|
|
Cl.25.20 (Supply Connection and External Flexible Cords ) |
- |
|
|
|
Cl.26.1 of IS 302-1:2008 (Terminal for External Conductors
) |
- |
|
|
|
Cl.26.10 of IS 302-1:2008 (Terminal for External Conductors
) |
- |
|
|
|
Cl.26.11 of IS 302-1:2008 (Terminal for External Conductors
) |
- |
|
|
|
Cl.27.1 of 302-1:2008 (Provision for Earthing.) |
- |
|
|
|
Cl.27.5 of 302-1:2008 (Provision for Earthing.) |
- |
|
|
|
Cl.28 of 302-1:2008 (Screws and Connections.) |
- |
|
|
|
Cl.29 & IS:302-1:2008 (Clearances, Creepage Distances and Solid Insulation) |
- |
|
|
|
Cl.29 & IS:302-1:2008 (Clearances, Creepage Distances and Solid Insulation) |
- |
|
|
|
Cl.30 & IS:302-1:2008 (Resistance to Heat and Fire) |
- |
|
|
|
Cl.30.2.2 of 302-1:2008 (Resistance to Heat and Fire) |
- |
|
|
|
Cl.31 & IS:302-1:2008 (Resistance to Rusting.) |
- |
|
|
|
Cl.32 & IS:302-1:2008 (Radition,Toxicity and similar Hazards.) |
- |
|
|
|
|
Complete
|
|
- |
Excluding 1. Cl. 14 Transient Overvoltage Test IS 302-1:2008 2. Cl. 19.11 and Cl. 19.12 abnormal test (for Electronic circuit) 3. Cl.24 Component Test IS 302-1:2008 |
135 |
IS 302 : Part 2 : Sec 14 (2009) |
Safety of household and similar electrical appliances: Part 2 particular requirements: Sec 14 electric kitchen machines (First Revision) |
- |
-
|
Rs.9800/- View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
6 (Classification- IS 302-1 ) |
- |
|
|
|
6 (Classification- IS 302-1) |
- |
|
|
|
7.1 (Marking- IS 302-1) |
- |
|
|
|
7.1 (Marking- IS 302-1) |
- |
|
|
|
7.1 (Marking- IS 302-1) |
- |
|
|
|
7.1 (Marking- IS 302-1) |
- |
|
|
|
7.1 (Marking- IS 302-1) |
- |
|
|
|
7.1 (Marking- IS 302-1) |
- |
|
|
|
7.1 (Marking- IS 302-1) |
- |
|
|
|
7.1 (Marking- IS 302-1) |
- |
|
|
|
7.3 (Marking- IS 302-1) |
- |
|
|
|
7.4 (Marking- IS 302-1) |
- |
|
|
|
7.6 (Marking- IS 302-1) |
- |
|
|
|
7.7 (Marking- IS 302-1) |
- |
|
|
|
7.8 (Marking- IS 302-1) |
- |
|
|
|
7.11 (Marking- IS 302-1) |
- |
|
|
|
7.12 (Marking- IS 302-1) |
- |
|
|
|
7.13 (Marking- IS 302-1) |
- |
|
|
|
7.14 (Marking- IS 302-1) |
- |
|
|
|
7.15 (Marking- IS 302-1) |
- |
|
|
|
7.101 (Marking) |
- |
|
|
|
8 ( Protection Against Electric Shock, IS 302-1) |
- |
|
|
|
10 (Power Input and Current, IS 302-1) |
- |
|
|
|
11 (Heating, IS 302-1) |
- |
|
|
|
11 (Heating, IS 302-1) |
- |
|
|
|
11 (Heating, IS 302-1) |
- |
|
|
|
11 (Heating, IS 302-1) |
- |
|
|
|
11 (Heating, IS 302-1) |
- |
|
|
|
8 ( Protection Against Electric Shock, IS 302-1) |
- |
|
|
|
13 (Electrical Insulation and Leakage Current at Operating Temperature: Leakage current, IS 302-1) |
- |
|
|
|
13 (Electrical Insulation and Leakage Current at Operating Temperature: High Voltage, IS 302-1) |
- |
|
|
|
15.1 (Moisture Resistance, IS 302-1) |
- |
|
|
|
15.2 (Moisture Resistance, IS 302-1) |
- |
|
|
|
15.1 (Moisture Resistance, IS 302-1) |
- |
|
|
|
16 (Electrical Insulation and Leakage Current at Operating Temperature: Leakage current, IS 302-1) |
- |
|
|
|
16 (Electrical Insulation and Leakage Current at Operating Temperature: High Voltage, IS 302-1) |
- |
|
|
|
19.7 (Abnormal Operation, IS 302-1) |
- |
|
|
|
19.8 (Abnormal Operation, IS 302-1) |
- |
|
|
|
19.9 (Abnormal Operation, IS 302-1) |
- |
|
|
|
19.1 (Abnormal Operation, IS 302-1) |
- |
|
|
|
19.101 (Abnormal Operation) |
- |
|
|
|
19.102 (Abnormal Operation) |
- |
|
|
|
20.1 (Stability & Mechanical Hazards, IS 302-1) |
- |
|
|
|
20.2 (Stability & Mechanical Hazards, IS 302-1) |
- |
|
|
|
20.101 (Stability & Mechanical Hazards) |
- |
|
|
|
20.102 (Stability & Mechanical Hazards) |
- |
|
|
|
20.103 (Stability & Mechanical Hazards) |
- |
|
|
|
20.104 (Stability & Mechanical Hazards) |
- |
|
|
|
20.105 (Stability & Mechanical Hazards) |
- |
|
|
|
20.106 (Stability & Mechanical Hazards) |
- |
|
|
|
20.107 (Stability & Mechanical Hazards) |
- |
|
|
|
20.108 (Stability & Mechanical Hazards) |
- |
|
|
|
20.109 (Stability & Mechanical Hazards) |
- |
|
|
|
20.110 (Stability & Mechanical Hazards) |
- |
|
|
|
20.111 (Stability & Mechanical Hazards) |
- |
|
|
|
20.112 (Stability & Mechanical Hazards) |
- |
|
|
|
20.113 (Stability & Mechanical Hazards) |
- |
|
|
|
20.114 (Stability & Mechanical Hazards) |
- |
|
|
|
20.115 (Stability & Mechanical Hazards) |
- |
|
|
|
20.116 (Stability & Mechanical Hazards) |
- |
|
|
|
21.1 (Mechanical Strength, IS 302-1) |
- |
|
|
|
21.2 (Mechanical Strength, IS 302-1) |
- |
|
|
|
22 (Construction, IS 302-1) |
- |
|
|
|
22.101 (Construction) |
- |
|
|
|
22.102 (Construction) |
- |
|
|
|
23.1 (Internal Wiring, IS 302-1) |
- |
|
|
|
23.2 (Internal Wiring, IS 302-1) |
- |
|
|
|
23.3 (Internal Wiring, IS 302-1) |
- |
|
|
|
23.4 (Internal Wiring, IS 302-1) |
- |
|
|
|
23.5 (Internal Wiring, IS 302-1) |
- |
|
|
|
23.6 (Internal Wiring, IS 302-1) |
- |
|
|
|
23.7 (Internal Wiring, IS 302-1) |
- |
|
|
|
23.8 (Internal Wiring, IS 302-1) |
- |
|
|
|
23.9 (Internal Wiring, IS 302-1) |
- |
|
|
|
23.10 (Internal Wiring, IS 302-1) |
- |
|
|
|
24.1 (Components, IS 302-1) |
- |
|
|
|
24.2 (Components, IS 302-1) |
- |
|
|
|
24.5 (Components, IS 302-1) |
- |
|
|
|
24.6 (Components, IS 302-1) |
- |
|
|
|
25.1 (Supply Connection and External Flexible Cords, IS 302-1) |
- |
|
|
|
25.5 (Supply Connection and External Flexible Cords, IS 302-1) |
- |
|
|
|
25.6 (Supply Connection and External Flexible Cords, IS 302-1) |
- |
|
|
|
25.7 (Supply Connection and External Flexible Cords, IS 302-1) |
- |
|
|
|
25.8 (Supply Connection and External Flexible Cords, IS 302-1) |
- |
|
|
|
26.9 (Supply Connection and External Flexible Cords, IS 302-1) |
- |
|
|
|
25.1 (Supply Connection and External Flexible Cords, IS 302-1) |
- |
|
|
|
25.11 (Supply Connection and External Flexible Cords, IS 302-1) |
- |
|
|
|
25.12 (Supply Connection and External Flexible Cords, IS 302-1) |
- |
|
|
|
25.13 (Supply Connection and External Flexible Cords, IS 302-1) |
- |
|
|
|
25.14 (Supply Connection and External Flexible Cords, IS 302-1) |
- |
|
|
|
25.15 (Supply Connection and External Flexible Cords, IS 302-1) |
- |
|
|
|
25.16 (Supply Connection and External Flexible Cords, IS 302-1) |
- |
|
|
|
25.17 (Supply Connection and External Flexible Cords, IS 302-1) |
- |
|
|
|
25.18 (Supply Connection and External Flexible Cords, IS 302-1) |
- |
|
|
|
25.19 (Supply Connection and External Flexible Cords, IS 302-1) |
- |
|
|
|
25.2 (Supply Connection and External Flexible Cords, IS 302-1) |
- |
|
|
|
25.21 (Supply Connection and External Flexible Cords, IS 302-1) |
- |
|
|
|
25.22 (Supply Connection and External Flexible Cords, IS 302-1) |
- |
|
|
|
26 (Terminals for External Conductors, IS 302-1) |
- |
|
|
|
27 (Provision for Earthing, IS 302-1) |
- |
|
|
|
27.2 (Provision for Earthing, IS 302-1) |
- |
|
|
|
27.3 (Provision for Earthing, IS 302-1) |
- |
|
|
|
27.4 (Provision for Earthing, IS 302-1) |
- |
|
|
|
27.5 (Provision for Earthing, IS 302-1) |
- |
|
|
|
28 (Screws & Connections, IS 302-1) |
- |
|
|
|
29.1 (Clearances, Creepage distances and Solid Insulation, IS 302-1) |
- |
|
|
|
29.2 (Clearances, Creepage distances and Solid Insulation, IS 302-1) |
- |
|
|
|
30.1 (Resistance to Heat and Fire, IS 302-1) |
- |
|
|
|
30.2 (Resistance to Heat and Fire, IS 302-1) |
- |
|
|
|
31 (Resistance of Rusting, IS 302-1) |
- |
|
|
|
32 (Radiation, Toxicity and similar Hazard IS 302-1) |
- |
|
|
|
|
Partial
|
|
- |
Excluding 1. Cl. 14 Transient Overvoltage Test IS 302-1:2008 2. Cl. 19.11 and Cl. 19.12 abnormal test (for Electronic circuit) 3. Cl.24 Component Test IS 302-1:2008 4.Except Can openers,Cheese graters,Churns(heavy cream and buttermilk),Food mixers with beaters for mixing cake batter,Ice-cream machines,Knives,Mincers |
136 |
IS 302 : Part 2 : Sec 3 (2007) |
Safety of household and similar electrical appliances: Part 2 particular requirements: Sec 3 electric iron (First Revision) |
- |
-
|
Rs.8330/- View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
6 (Classification- IS 302-1 ) |
- |
|
|
|
6 (Classification- IS 302-1) |
- |
|
|
|
7.1 (Marking- IS 302-1) |
- |
|
|
|
7.1 (Marking- IS 302-1) |
- |
|
|
|
7.1 (Marking- IS 302-1) |
- |
|
|
|
7.1 (Marking- IS 302-1) |
- |
|
|
|
7.1 (Marking- IS 302-1) |
- |
|
|
|
7.1 (Marking- IS 302-1) |
- |
|
|
|
7.1 (Marking- IS 302-1) |
- |
|
|
|
7.1 (Marking- IS 302-1) |
- |
|
|
|
7.1 (Marking- IS 302-1) |
- |
|
|
|
7.3 (Marking- IS 302-1) |
- |
|
|
|
7.4 (Marking- IS 302-1) |
- |
|
|
|
7.6 (Marking- IS 302-1) |
- |
|
|
|
7.7 (Marking- IS 302-1) |
- |
|
|
|
7.8 (Marking- IS 302-1) |
- |
|
|
|
7.11 (Marking- IS 302-1) |
- |
|
|
|
7.12 (Marking- IS 302-1) |
- |
|
|
|
7.13 (Marking- IS 302-1) |
- |
|
|
|
7.14 (Marking- IS 302-1) |
- |
|
|
|
7.15 (Marking- IS 302-1) |
- |
|
|
|
7.101 (Marking) |
- |
|
|
|
8 ( Protection Against Electric Shock, IS 302-1) |
- |
|
|
|
10 (Power Input and Current, IS 302-1) |
- |
|
|
|
11 (Heating, IS 302-1) |
- |
|
|
|
11 (Heating, IS 302-1) |
- |
|
|
|
11 (Heating, IS 302-1) |
- |
|
|
|
11 (Heating, IS 302-1) |
- |
|
|
|
11 (Heating, IS 302-1) |
- |
|
|
|
11 (Heating, IS 302-1) |
- |
|
|
|
11 (Heating, IS 302-1) |
- |
|
|
|
11 (Heating, IS 302-1) |
- |
|
|
|
13 (Electrical Insulation and Leakage Current at Operating Temperature: Leakage current, IS 302-1) |
- |
|
|
|
13 (Electrical Insulation and Leakage Current at Operating Temperature: High Voltage, IS 302-1) |
- |
|
|
|
15.1 (Moisture Resistance, IS 302-1) |
- |
|
|
|
15.2 (Moisture Resistance, IS 302-1) |
- |
|
|
|
15.3 (Moisture Resistance, IS 302-1) |
- |
|
|
|
16 (Electrical Insulation and Leakage Current at Operating Temperature: Leakage current, IS 302-1) |
- |
|
|
|
16 (Electrical Insulation and Leakage Current at Operating Temperature: High Voltage, IS 302-1) |
- |
|
|
|
19.4 (Abnormal Operation, IS 302-1) |
- |
|
|
|
19.4 (Abnormal Operation, IS 302-1) |
- |
|
|
|
19.5 (Abnormal Operation, IS 302-1) |
- |
|
|
|
19.5 (Abnormal Operation, IS 302-1) |
- |
|
|
|
19.7 (Abnormal Operation) |
- |
|
|
|
19.9 (Abnormal Operation) |
- |
|
|
|
19.1 (Abnormal Operation) |
- |
|
|
|
19.101 (Abnormal Operation) |
- |
|
|
|
20.1 (Stability & Mechanical Hazards, IS 302-1) |
- |
|
|
|
20.2 (Stability & Mechanical Hazards, IS 302-1) |
- |
|
|
|
21.1 (Mechanical Strength, IS 302-1) |
- |
|
|
|
21.2 (Mechanical Strength, IS 302-1) |
- |
|
|
|
21.101 (Mechanical Strength, IS 302-2-3) |
- |
|
|
|
22 (Construction, IS 302-1) |
- |
|
|
|
22.101 (Construction) |
- |
|
|
|
22.102 (Construction) |
- |
|
|
|
22.103 (Construction) |
- |
|
|
|
22.104 (Construction) |
- |
|
|
|
22.105 (Construction) |
- |
|
|
|
22.106 (Construction) |
- |
|
|
|
22.107 (Construction) |
- |
|
|
|
23.1 (Internal Wiring, IS 302-1) |
- |
|
|
|
23.2 (Internal Wiring, IS 302-1) |
- |
|
|
|
23.3 (Internal Wiring, IS 302-1) |
- |
|
|
|
23.4 (Internal Wiring, IS 302-1) |
- |
|
|
|
23.5 (Internal Wiring, IS 302-1) |
- |
|
|
|
23.6 (Internal Wiring, IS 302-1) |
- |
|
|
|
23.7 (Internal Wiring, IS 302-1) |
- |
|
|
|
23.8 (Internal Wiring, IS 302-1) |
- |
|
|
|
23.9 (Internal Wiring, IS 302-1) |
- |
|
|
|
23.10 (Internal Wiring, IS 302-1) |
- |
|
|
|
25.6 (Supply Connection and External Flexible Cords, IS 302-1) |
- |
|
|
|
24.1 (Components, IS 302-1) |
- |
|
|
|
24.2 (Components, IS 302-1) |
- |
|
|
|
24.4 (Components, IS 302-1) |
- |
|
|
|
24.5 (Components, IS 302-1) |
- |
|
|
|
24.6 (Components, IS 302-1) |
- |
|
|
|
25.1 (Supply Connection and External Flexible Cords, IS 302-1) |
- |
|
|
|
25.5 (Supply Connection and External Flexible Cords, IS 302-1) |
- |
|
|
|
25.7 (Supply Connection and External Flexible Cords, IS 302-1) |
- |
|
|
|
25.8 (Supply Connection and External Flexible Cords, IS 302-1) |
- |
|
|
|
23.9 (Internal Wiring, IS 302-1) |
- |
|
|
|
25.14 (Supply Connection and External Flexible Cords, IS 302-1) |
- |
|
|
|
25.14 (Supply Connection and External Flexible Cords, IS 302-1) |
- |
|
|
|
25.15 (Supply Connection and External Flexible Cords, IS 302-1) |
- |
|
|
|
25.16 (Supply Connection and External Flexible Cords, IS 302-1) |
- |
|
|
|
25.15 (Supply Connection and External Flexible Cords, IS 302-1) |
- |
|
|
|
25.17 (Supply Connection and External Flexible Cords, IS 302-1) |
- |
|
|
|
25.18 (Supply Connection and External Flexible Cords, IS 302-1) |
- |
|
|
|
25.19 (Supply Connection and External Flexible Cords, IS 302-1) |
- |
|
|
|
25.2 (Supply Connection and External Flexible Cords, IS 302-1) |
- |
|
|
|
25.21 (Supply Connection and External Flexible Cords, IS 302-1) |
- |
|
|
|
25.22 (Supply Connection and External Flexible Cords, IS 302-1) |
- |
|
|
|
26 (Terminals for External Conductors, IS 302-1) |
- |
|
|
|
27.1 (Provision for Earthing, IS 302-1) |
- |
|
|
|
27.2 (Provision for Earthing, IS 302-1) |
- |
|
|
|
27.3 (Provision for Earthing, IS 302-1) |
- |
|
|
|
27.4 (Provision for Earthing, IS 302-1) |
- |
|
|
|
27.5 (Provision for Earthing, IS 302-1) |
- |
|
|
|
28 (Screws & Connections, IS 302-1) |
- |
|
|
|
29.1 (Clearances, Creepage distances and Solid Insulation, IS 302-1) |
- |
|
|
|
29.2 (Clearances, Creepage distances and Solid Insulation, IS 302-1) |
- |
|
|
|
30.1 (Resistance to Heat, Fire & Tracking, IS 302-1) |
- |
|
|
|
30.2 (Resistance to Heat, Fire & Tracking, IS 302-1) |
- |
|
|
|
31 (Resistance of Rusting, IS 302-1) |
- |
|
|
|
32 (Radiation, Toxicity and similar Hazard IS 302-1) |
- |
|
|
|
|
Partial
|
|
- |
Excluding Cl. 22.105 construction for cordless iron ,Cl.22.16 Cord reel test setup,Cl. 14 Transient Overvoltage Test IS 302-1:2008 ,Cl. 19.11 and Cl. 19.12 abnormal test (for Electronic circuit) ,Cl.24 Component Test IS 302-1:2008 |
137 |
IS 8041 (1990) |
Rapid hardening portland cement - Specific4tion (Second Revision) |
- |
-
|
- View breakup
Testing charges for the product are: Including Transverse Strength (optional test) test 9,100.00 Excluding Transverse Strength (optional test) test 7,900.00 -Testing charges for only chemical test report: 4,300.00 -Testing charges for only physical test report including optional tests: 4,800.00 -Testing charges for only physical test report excluding optional tests: 3,600.00
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
6.1 (Fineness 4031 Part 2) |
- |
|
|
|
6.1 (Fineness 4031 Part 2) |
- |
|
|
|
6.2.1 (Expansion by Le Chatelier- 4031 Part 3) |
- |
|
|
|
6.2.1 (Expansion by Autoclave- 4031 Part 3) |
- |
|
|
|
6.3 a) (Setting Time Initial- 4031 Part 5) |
- |
|
|
|
6.3 a) (Setting Time Initial- 4031 Part 5) |
- |
|
|
|
6.4 a) (Compressive Strength At 24 hrs ± 30 minutes - IS 4031 Part 6) |
- |
|
|
|
5.1 - Table - 1 i (Ratio of percentage of lime to percentages of silica, alumina and iron oxide - Cl 4 of IS 4032:1985) |
- |
|
|
|
5.1 - Table - 1 ii (Ratio of percentage of alumina to that of iron oxide - Cl 4 of IS 4032:1985) |
- |
|
|
|
5.1 - Table - 1 iii (Insoluble residue - Cl 4.10 of IS 4032:1985) |
- |
|
|
|
5.1 - Table - 1 iv (Magnesia - Cl 4.8 of IS 4032:1985) |
- |
|
|
|
5.1 - Table - 1 v (Total Sulphur Content calculated as Sulphuric Anhydride (SO3) - Cl 4.9 of IS 4032:1985) |
- |
|
|
|
5.1 - Table - 1 vi (Total loss on ignition - Cl 4.2 of IS 4032:1985) |
- |
|
|
|
|
Complete
|
|
- |
Test facility is complete |
138 |
IS 8042 (2015) |
White portland cement - Specification (Third Revision) |
- |
-
|
Rs 12050/- View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
6 -Table 2- i (Fineness 4031 Part 2) |
- |
|
|
|
6 -Table 2- ii- a (Expansion by Le Chatelier- 4031 Part 3) |
- |
|
|
|
6 -Table 2- ii- a (Expansion after aeration - 4031 Part 3) |
- |
|
|
|
6 -Table 2- ii- b (Expansion by Autoclave- 4031 Part 3) |
- |
|
|
|
6-Table 2- ii- b (Expansion after aeration- 4031 Part 3) |
- |
|
|
|
6 -Table 2- iii- a (Setting Time Initial- 4031 Part 5) |
- |
|
|
|
6 -Table 2- iv- a (Compressive Strength At 72 hrs ± 1 hr - IS 4031 Part 6) |
- |
|
|
|
5 - Table - 1 iii (Insoluble residue - Cl 4.10 of IS 4032:1985) |
- |
|
|
|
5 - Table - 1 i (Ratio of percentage of lime to percentages of silica, alumina and iron oxide - Cl 4 of IS 4032:1985) |
- |
|
|
|
5 - Table - 1 iv (Magnesia - Cl 4.8 of IS 4032:1985) |
- |
|
|
|
5 - Table - 1 v (Total Sulphur Content calculated as Sulphuric Anhydride (SO3) - Cl 4.9 of IS 4032:1985) |
- |
|
|
|
5 - Table - 1 vi (Loss on ignition - Cl 4.2 of IS 4032:1985) |
- |
|
|
|
5 - Table - 1 vii (Chloride content - Cl 4.13 of IS 4032:1985) |
- |
|
|
|
5 - Table - 1 ii (Iron oxide - Cl 4.5 of IS 4032:1985) |
- |
|
|
|
5 - Table - 1 iii (Insoluble residue - Cl 4.10 of IS 4032:1985) |
- |
|
|
|
|
Partial
|
|
- |
Excluding Degree of whiteness in terms of reflectance, Optional Test Transverse Strength |
139 |
IS 7231 (1994) |
plastic flushing cisterns for waterclosets and urinals |
- |
-
|
Rs.8100/- View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
Cl 5.1 (Cistern) |
- |
|
|
|
Cl 5.2 (Cover) |
- |
|
|
|
Cl 5.3 (Flush pipe) |
- |
|
|
|
Cl 5.3.1 (Flush pipe connection to cistern.) |
- |
|
|
|
Cl 5.4 (Inlet and overflow holes) |
- |
|
|
|
Cl 5.6 (Operating mechanism / lever) |
- |
|
|
|
Cl 5.8 (Overflow pipe) |
- |
|
|
|
4 ,Table- 1, S.No 2 AND AS PER IS 1239-1 (CARBON) |
- |
|
|
|
4 ,Table- 1, S.No 2 AND AS PER IS 1239-1 (SULPHUR) |
- |
|
|
|
4 ,Table- 1, S.No 2 AND AS PER IS 1239-1 (MANGANESE) |
- |
|
|
|
4 ,Table- 1, S.No 2 AND AS PER IS 1239-1 (PHOSPHORUS) |
- |
|
|
|
|
Partial
|
|
- |
Test facility not availabe |
140 |
IS 14542 (1998) |
Partly skimmed milk powder specification |
ALL TYPE |
-
|
- View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
Table 1(i) (Moisture Type I (IS 11623)) |
- |
|
|
|
Table 1(i) (Moisture Type II (IS 11623)) |
- |
|
|
|
Table 1(ii) (Total solids (milk solids and added salts) Type I (IS 11623)) |
- |
|
|
|
Table 1(ii) (Total solids (milk solids and added salts) Type II (IS 11623)) |
- |
|
|
|
Table 1(iii) (Milk fat, Type I (IS I1722)) |
- |
|
|
|
Table 1(iii) (Milk fat, Type II (IS I1722)) |
- |
|
|
|
Table 1(iv) (Insolubility index, a) Roller dried Type I (IS 12759)) |
- |
|
|
|
Table 1(iv) (Insolubility index, a) Roller dried Type II (IS 12759)) |
- |
|
|
|
Table 1(iv) (Insolubility index, b) Spray dried Type I (IS 12759)) |
- |
|
|
|
Table 1(iv) (Insolubility index, b) Spray dried Type II (IS 12759)) |
- |
|
|
|
Table 1(v) (Total ash Type I (Annex B of IS 14433 - Part 1)) |
- |
|
|
|
Table 1(v) (Total ash Type II (Annex B of IS 14433 - Part 1)) |
- |
|
|
|
Table 1(vi) (Titratable acidity (as lactic acid) Type I (IS 11766)) |
- |
|
|
|
Table 1(vi) (Titratable acidity (as lactic acid) Type II (IS 11766)) |
- |
|
|
|
Cl 6.6.1 (Bacterial Count (IS 5402)) |
- |
|
|
|
Cl 6.6.2 (Coliform Count ((IS 5402)) |
- |
|
|
|
|
Partial
|
|
- |
Test facility is complete |
141 |
IS 9762 (1994) |
Specification for polyethylene floats (Spherical) for float valves |
- |
-
|
Rs.4500/ View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
6, 6.1 (Table 1) (Dimensions and Tolerances) |
- |
|
|
|
6.2.1 (Wall Thickness) |
- |
|
|
|
6.2.2 (Wall Thickness) |
- |
|
|
|
6, 6.1 (Table 1) (Tapping of boss, A) |
- |
|
|
|
6, 6.1 (Table 1) (Insert wall thickness, t ( below threads )) |
- |
|
|
|
6, 6.1 (Table 1) (Insert base thickcess, T) |
- |
|
|
|
6, 6.1 (Table 1) (Axial length of thread, B (min)) |
- |
|
|
|
cl 8.1 (Leakage & water ab. Test) |
- |
|
|
|
cl 8.2 (Deflection Test) |
- |
|
|
|
cl 8.3 (Impact test) |
- |
|
|
|
cl 8.4 (Boss test) |
- |
|
|
|
|
Partial
|
|
- |
Excluding dimensional test |
142 |
IS 1660 (2009) |
Wrought aluminium utensils - Specification (First Revision) |
- |
-
|
Rs 6760/- View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
3.1 (Classification Heavy/Medium/L:ight) |
- |
|
|
|
4 (Material) |
- |
|
|
|
0.5 (Fabrication) |
- |
|
|
|
5.1 (The utensil shall be pressed or spun from one piece) |
- |
|
|
|
5.2 ( Body Thickness of the thinnest part of the finished utensil, mm Not declared ) |
- |
|
|
|
5.2 (Lid Thickness of the finished utensil, mm) |
- |
|
|
|
6.1 & Table 1 ( i) Name of Utensil ) |
- |
|
|
|
6.1 & Table 1 (ii) Shape of Utensil) |
- |
|
|
|
6.1 & Table 1 ( Nominal Size, mm) |
- |
|
|
|
6.1 & Table 1 (Inside dia, Φ D mm Not declared ) |
- |
|
|
|
6.1 & Table 1 (Outside dia Ф NA) |
- |
|
|
|
6.1 & Table 1 (Height NA) |
- |
|
|
|
6.1 & Table 1 (Capacity, l NA) |
- |
|
|
|
6.1 ( Minimum sheet thickness for nominal size ) |
- |
|
|
|
7.1 (HANDLES ,When fitted shall be of aluminium, stainless steel or of other suitable fire resistance material These shall be fastened to the utensils by tightly drawn aluminium or stainless steel rivets, by welding, by screwing to cast bosses or by riveting between flange at the end of the handles. Handles shall be so shaped and positioned to facilitate the carrying and handling of the utensils in normal use ) |
- |
|
|
|
7.2 (Handles shall be sufficiently strong to support a mass in the utensils equivalent to three times the mass of the water capacity of the utensils in the position of normal use without visible permanent deformation of the handle or utensil) |
- |
|
|
|
8.1 (The utensils shall be clean reasonably free from distortion, dents, wrinkles, wavy surface, burrs, scratches, pitting and deep tool marks and other surface defects) |
- |
|
|
|
8.2 (The design of the utensils shall be such that it is easy to clean and prevent accumulation of dirt) |
- |
|
|
|
8.4.3 (Abrasion Resistance When the coating surface is rubbed two or three times with emery paper with emery conforming to grit number 180 using medium finger pressure, it shall not abrade the surface but shall skid over the surface showing not more than a trace of whitening of the surface) |
- |
|
|
|
8.4.4 (The colour of the hard anodic coating varies depending upon the alloy, thickness of the coating and electrolye. Normally the colour may vary from dark grey (almost black) to light grey. ) |
- |
|
|
|
9 (The manufacturer shall provide full instructions for use and cleaning for coated or hard anodized utensils) |
- |
|
|
|
10 (Each vessel shall be legibly and indelibly stamped on the outside surface or handle with the manufacturer’s name or registered trade-mark, size and thickness or class. ) |
- |
|
|
|
|
Partial
|
|
- |
Excluding Material tests,anodized and non stick coating, test for lunch boxes. |
143 |
IS 8794 (1988) |
Specification for cast iron detachable joints for use with asbestos cement pressure pipes (First Revision) |
- |
-
|
3900/- View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
6.1, Table 2 (External Dia of AC Pipe(D2)) |
- |
|
|
|
6.1, Table 2 (Inside diaFlange(DI)) |
- |
|
|
|
6.1, Table 2 (External Dia at Centre(DEC)) |
- |
|
|
|
6.1, Table 2 (Thickness(t)) |
- |
|
|
|
6.1, Table 3 (Nominal Dia of Bolt(do)) |
- |
|
|
|
6.1, Table 3 (Minimum prefared length of bolt(L)) |
- |
|
|
|
6.1, Table 4 (Mass of joints) |
- |
|
|
|
8.4 (Coating) |
- |
|
|
|
|
Partial
|
|
- |
HST for size above 300 mm, Facility for Chemical tests not available |
144 |
IS 6595 : Part 2 (1993) |
Horizontal centrifugal pumps for clear, cOld water: Part 2 general pmUrpose (Other than agricultural and rural water supply) - Specification (Second Revision) |
- |
-
|
- View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
10.5 (Guarantee of Workmanship and Material) |
- |
|
|
|
10.1 (Pump test, tolerances, and verification of guarantee on Pump Performance) |
- |
|
|
|
|
Complete
|
|
- |
Test facility is to be deleteed from NRL scope |
145 |
IS 1166 (1986) |
Specification for condensed milk, partly skimmed and skimmed condensed milk (Second Revision) |
- |
-
|
- View breakup
The testing charges are fixed at Rs. 10430.00
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
Table 1 (i) (Apendix B) (Total milk solids - Partly Skimmed Condenied Milk) |
- |
|
|
|
Table 1 (ii) (IS : 11762-
1986) (Fat -Condensed Milk) |
- |
|
|
|
Table 1 (iii) (Apendix C) (Sucrose -Condensed Milk) |
- |
|
|
|
Table 1 (vi) (Apendix D) (Titratable acidity (as lactic acid) -Condensed Milk) |
- |
|
|
|
Table 1 (v) (Apendix E) (Accelerated starage test -Condensed Milk) |
- |
|
|
|
Cl.5.1.10.1 (Salmonella IS 5887 Part 3) |
- |
|
|
|
Cl.5.1.10.1 (Shigella IS 5887 Part 7) |
- |
|
|
|
Cl.5.1.10.2 (Coliform Count IS 5401 Part 1) |
- |
|
|
|
Cl.5.1.10.3 (Yeast and Mould Count IS 5403) |
- |
|
|
|
Cl.5.1.10.4 (Coagulase positive Staphylococcus aureus IS 5887 Part 2) |
- |
|
|
|
Cl.5.1.10.5 (Escherichia coli IS 5887 Part 1) |
- |
|
|
|
|
Partial
|
|
- |
Microbiological testing is complete. Excluding Except Lactate Crystals |
146 |
IS 2082 (2018) |
Stationary storage type electric water heaters - Specification (Fifth Revision) |
- |
-
|
- View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
6 (Classification ) |
- |
|
|
|
6 (Classification ) |
- |
|
|
|
7 (Marking) |
- |
|
|
|
7 (Marking) |
- |
|
|
|
7 (Marking) |
- |
|
|
|
7 (Marking) |
- |
|
|
|
7 (Marking) |
- |
|
|
|
7 (Marking) |
- |
|
|
|
7 (Marking) |
- |
|
|
|
7 (Marking) |
- |
|
|
|
7 (Marking) |
- |
|
|
|
7 (Marking) |
- |
|
|
|
7 (Marking) |
- |
|
|
|
7 (Marking) |
- |
|
|
|
7 (Marking) |
- |
|
|
|
7 (Marking) |
- |
|
|
|
7 (Marking) |
- |
|
|
|
7 (Marking) |
- |
|
|
|
7 (Marking) |
- |
|
|
|
7 (Marking) |
- |
|
|
|
7 (Marking) |
- |
|
|
|
7 (Marking) |
- |
|
|
|
7 (Marking) |
- |
|
|
|
7 (Marking) |
- |
|
|
|
7 (Marking) |
- |
|
|
|
7 (Marking) |
- |
|
|
|
7 (Marking) |
- |
|
|
|
7 (Marking) |
- |
|
|
|
7 (Marking) |
- |
|
|
|
(Cl.8 of IS 302-2-21:2011) (Protection Against Access to Live Parts) |
- |
|
|
|
(Cl.10 of IS 302-2-21: 2011) (Power Input & Current) |
- |
|
|
|
(Cl.11 of 302-2-21:2011) (Heating) |
- |
|
|
|
(Cl.11 of 302-2-21:2011) (Heating) |
- |
|
|
|
(Cl.13 of IS 302-2-21:2011) (Leakage Current ) |
- |
|
|
|
(Cl.15 of IS 302-2-21-2011) (Moisture Resistance) |
- |
|
|
|
(Cl.15 of IS 302-2-21-2011) (Moisture Resistance) |
- |
|
|
|
(Cl.15 of IS 302-2-21-2011) (Moisture Resistance) |
- |
|
|
|
(Cl.19 of IS 302-2-21:2011) (Abnormal Operation) |
- |
|
|
|
(Cl.19 of IS 302-2-21:2011) (Abnormal Operation) |
- |
|
|
|
(Cl.19 of IS 302-2-21:2011) (Abnormal Operation) |
- |
|
|
|
(Cl.19 of IS 302-2-21:2011) (Abnormal Operation) |
- |
|
|
|
(Cl.20 of IS 302-2-21:2011) (Stability & Mechanical Hazards) |
- |
|
|
|
(Cl.21ofIS302-2-21:2011) (Mechanical strength) |
- |
|
|
|
(Cl.22 Of
IS 302-2-21:2011) (Construction) |
- |
|
|
|
(Cl.22 Of
IS 302-2-21:2011) (Construction) |
- |
|
|
|
(Cl.22 Of
IS 302-2-21:2011) (Construction) |
- |
|
|
|
(Cl.22 Of
IS 302-2-21:2011) (Construction) |
- |
|
|
|
(Cl.22 Of
IS 302-2-21:2011) (Construction) |
- |
|
|
|
(Cl.22 Of
IS 302-2-21:2011) (Construction) |
- |
|
|
|
(Cl.22 Of
IS 302-2-21:2011) (Construction) |
- |
|
|
|
(Cl.22 Of
IS 302-2-21:2011) (Construction) |
- |
|
|
|
(Cl.22 Of
IS 302-2-21:2011) (Construction) |
- |
|
|
|
(Cl.22 Of
IS 302-2-21:2011) (Construction) |
- |
|
|
|
(Cl.22 Of
IS 302-2-21:2011) (Construction) |
- |
|
|
|
(Cl.22 Of
IS 302-2-21:2011) (Construction) |
- |
|
|
|
(Cl.22 Of
IS 302-2-21:2011) (Construction) |
- |
|
|
|
(Cl.22 Of
IS 302-2-21:2011) (Construction) |
- |
|
|
|
(Cl.22 Of
IS 302-2-21:2011) (Construction) |
- |
|
|
|
(Cl.22 Of
IS 302-2-21:2011) (Construction) |
- |
|
|
|
(Cl.22 Of
IS 302-2-21:2011) (Construction) |
- |
|
|
|
(Cl.22 Of
IS 302-2-21:2011) (Construction) |
- |
|
|
|
(Cl.22 Of
IS 302-2-21:2011) (Construction) |
- |
|
|
|
(Cl.22 Of
IS 302-2-21:2011) (Construction) |
- |
|
|
|
(Cl.22 Of
IS 302-2-21:2011) (Construction) |
- |
|
|
|
(Cl.22 Of
IS 302-2-21:2011) (Construction) |
- |
|
|
|
(Cl.22 Of
IS 302-2-21:2011) (Construction) |
- |
|
|
|
(Cl.22 Of
IS 302-2-21:2011) (Construction) |
- |
|
|
|
(Cl.22 Of
IS 302-2-21:2011) (Construction) |
- |
|
|
|
(Cl.22 Of
IS 302-2-21:2011) (Construction) |
- |
|
|
|
(Cl.22 Of
IS 302-2-21:2011) (Construction) |
- |
|
|
|
(Cl.22 Of
IS 302-2-21:2011) (Construction) |
- |
|
|
|
(Cl.22 Of
IS 302-2-21:2011) (Construction) |
- |
|
|
|
(Cl.22 Of
IS 302-2-21:2011) (Construction) |
- |
|
|
|
(Cl.22 Of
IS 302-2-21:2011) (Construction) |
- |
|
|
|
(Cl.22 Of
IS 302-2-21:2011) (Construction) |
- |
|
|
|
(Cl.22 Of
IS 302-2-21:2011) (Construction) |
- |
|
|
|
(Cl.22 Of
IS 302-2-21:2011) (Construction) |
- |
|
|
|
(Cl.22 Of
IS 302-2-21:2011) (Construction) |
- |
|
|
|
(Cl.22 Of
IS 302-2-21:2011) (Construction) |
- |
|
|
|
(Cl.22 Of
IS 302-2-21:2011) (Construction) |
- |
|
|
|
(Cl.22 Of
IS 302-2-21:2011) (Construction) |
- |
|
|
|
(Cl.22 Of
IS 302-2-21:2011) (Construction) |
- |
|
|
|
(Cl.22 Of
IS 302-2-21:2011) (Construction) |
- |
|
|
|
(Cl.22 Of
IS 302-2-21:2011) (Construction) |
- |
|
|
|
(Cl.22 Of
IS 302-2-21:2011) (Construction) |
- |
|
|
|
(Cl.22 Of
IS 302-2-21:2011) (Construction) |
- |
|
|
|
(Cl.22 Of
IS 302-2-21:2011) (Construction) |
- |
|
|
|
(Cl.22 Of
IS 302-2-21:2011) (Construction) |
- |
|
|
|
(Cl.22 Of
IS 302-2-21:2011) (Construction) |
- |
|
|
|
(Cl.22 Of
IS 302-2-21:2011) (Construction) |
- |
|
|
|
(Cl.22 Of
IS 302-2-21:2011) (Construction) |
- |
|
|
|
(Cl. 23 of IS 302-2-21: 2011) (Internal Wiring
) |
- |
|
|
|
(Cl. 23 of IS 302-2-21: 2011) (Internal Wiring
) |
- |
|
|
|
(Cl. 23 of IS 302-2-21: 2011) (Internal Wiring
) |
- |
|
|
|
(Cl. 23 of IS 302-2-21: 2011) (Internal Wiring
) |
- |
|
|
|
(Cl. 23 of IS 302-2-21: 2011) (Internal Wiring
) |
- |
|
|
|
(Cl. 23 of IS 302-2-21: 2011) (Internal Wiring
) |
- |
|
|
|
(Cl. 23 of IS 302-2-21: 2011) (Internal Wiring
) |
- |
|
|
|
(Cl. 23 of IS 302-2-21: 2011) (Internal Wiring
) |
- |
|
|
|
(Cl. 23 of IS 302-2-21: 2011) (Internal Wiring
) |
- |
|
|
|
(Cl. 23 of IS 302-2-21: 2011) (Internal Wiring
) |
- |
|
|
|
(Cl.24ofIS302-221:2011) (Component) |
- |
|
|
|
(Cl.24ofIS302-221:2011) (Component) |
- |
|
|
|
(Cl. 23 of IS 302-2-21: 2011) (Internal Wiring
) |
- |
|
|
|
(Cl.24ofIS302-221:2011) (Component) |
- |
|
|
|
(Cl.24ofIS302-221:2011) (Component) |
- |
|
|
|
(Cl.24ofIS302-221:2011) (Component) |
- |
|
|
|
(Cl.25 of IS 302-2-21:2011) (Supply Connection & External Flexible Cords) |
- |
|
|
|
(Cl.25 of IS 302-2-21:2011) (Supply Connection & External Flexible Cords) |
- |
|
|
|
(Cl.25 of IS 302-2-21:2011) (Supply Connection & External Flexible Cords) |
- |
|
|
|
(Cl.25 of IS 302-2-21:2011) (Supply Connection & External Flexible Cords) |
- |
|
|
|
(Cl.25 of IS 302-2-21:2011) (Supply Connection & External Flexible Cords) |
- |
|
|
|
(Cl.25 of IS 302-2-21:2011) (Supply Connection & External Flexible Cords) |
- |
|
|
|
(Cl.25 of IS 302-2-21:2011) (Supply Connection & External Flexible Cords) |
- |
|
|
|
(Cl.25 of IS 302-2-21:2011) (Supply Connection & External Flexible Cords) |
- |
|
|
|
(Cl.25 of IS 302-2-21:2011) (Supply Connection & External Flexible Cords) |
- |
|
|
|
(Cl.25 of IS 302-2-21:2011) (Supply Connection & External Flexible Cords) |
- |
|
|
|
(Cl.25 of IS 302-2-21:2011) (Supply Connection & External Flexible Cords) |
- |
|
|
|
(Cl.25 of IS 302-2-21:2011) (Supply Connection & External Flexible Cords) |
- |
|
|
|
(Cl.25 of IS 302-2-21:2011) (Supply Connection & External Flexible Cords) |
- |
|
|
|
(Cl.25 of IS 302-2-21:2011) (Supply Connection & External Flexible Cords) |
- |
|
|
|
(Cl.25 of IS 302-2-21:2011) (Supply Connection & External Flexible Cords) |
- |
|
|
|
(Cl.25 of IS 302-2-21:2011) (Supply Connection & External Flexible Cords) |
- |
|
|
|
(Cl.26 of IS 302-2-21: 2011) (Terminals for External Conductors) |
- |
|
|
|
(Cl.26 of IS 302-2-21: 2011) (Terminals for External Conductors) |
- |
|
|
|
(Cl.26 of IS 302-2-21: 2011) (Terminals for External Conductors) |
- |
|
|
|
(Cl.26 of IS 302-2-21: 2011) (Terminals for External Conductors) |
- |
|
|
|
(Cl.26 of IS 302-2-21: 2011) (Terminals for External Conductors) |
- |
|
|
|
(Cl.26 of IS 302-2-21: 2011) (Terminals for External Conductors) |
- |
|
|
|
(Cl.26 of IS 302-2-21: 2011) (Terminals for External Conductors) |
- |
|
|
|
(Cl.26 of IS 302-2-21: 2011) (Terminals for External Conductors) |
- |
|
|
|
(Cl.26 of IS 302-2-21: 2011) (Terminals for External Conductors) |
- |
|
|
|
(Cl.26 of IS 302-2-21: 2011) (Terminals for External Conductors) |
- |
|
|
|
(Cl.27 of IS 302-2-21:2011) (Provision for Earthing) |
- |
|
|
|
(Cl.27 of IS 302-2-21:2011) (Provision for Earthing) |
- |
|
|
|
(Cl.27 of IS 302-2-21:2011) (Provision for Earthing) |
- |
|
|
|
(Cl.27 of IS 302-2-21:2011) (Provision for Earthing) |
- |
|
|
|
(Cl.27 of IS 302-2-21:2011) (Provision for Earthing) |
- |
|
|
|
(Cl.27 of IS 302-2-21:2011) (Provision for Earthing) |
- |
|
|
|
(Cl.28 of IS 302-2-21:2011) (Screws & Connections) |
- |
|
|
|
(Cl.29ofIS302-2-21:2011) (Clearances, Creepage Distances and Solid Insulation) |
- |
|
|
|
(Cl.30 of IS 302-2-21:2011) (Resistance to Heat & Fire) |
- |
|
|
|
(Cl.30 of IS 302-2-21:2011) (Resistance to Heat & Fire) |
- |
|
|
|
(Cl.31 of IS 302-2-21:2011) (Resistance to Rusting) |
- |
|
|
|
(Cl.15 of IS 2082:2018) (Verification of the Rated Capacity) |
- |
|
|
|
(Cl.16 of IS 2082:2018) (Standing Loss per 24 Hours) |
- |
|
|
|
(Cl.17 of IS 2082:2018) (Hot Water Output) |
- |
|
|
|
(Cl.18 of IS 2082:2018) ( Reheating Time) |
- |
|
|
|
(Cl.19 of IS 2082:2018) (Mixing Factor) |
- |
|
|
|
(Cl.20 of IS 2082:2018) (Deviation of Dial Calibration) |
- |
|
|
|
(Cl.21 of IS 2082:2018) (Cyclic Temperature Variation) |
- |
|
|
|
(Cl.22 of IS 2082:2018) (Finish) |
- |
|
|
|
|
Partial
|
|
- |
Excluding Cl.24.102.1 and Cl.24.102.2 Electronic circuit and Software evaluation
Cl. 19.11 and Cl. 19.12 abnormal test (for Electronic circuit) |
147 |
IS 8462 (1977) |
Specification for sterilizer, portable, vertical, pressure type |
- |
-
|
For sterilizers with painted steel stand Rs.9580/-. For View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
4.1 (Shape and Dimensions) |
- |
|
|
|
4.2 (Thickness) |
- |
|
|
|
5.8 (Construction) |
- |
|
|
|
6.1 (Workmanship and Finish) |
- |
|
|
|
6.2 (Workmanship and Finish) |
- |
|
|
|
8.1 (Proof Pressure Test) |
- |
|
|
|
|
Partial
|
|
- |
Mechanical: Test facility is complete, Facility for chemical test is not available |
148 |
IS 8329 (2000) |
Centrifugally cast (Spun) ductile iron pressure pipes for water, gas and sewage - Specification (Third Revision) |
- |
-
|
Rs.7800/- View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
Cl 10 (Hardness & Tensile Test) |
- |
|
|
|
Cl 11 (Hydrostatic Test) |
- |
|
|
|
Cl 13 (Length, Diameter, Wall Thickness & Ovality) |
- |
|
|
|
|
Partial
|
|
- |
Excluding HST for size above 300 mm |
149 |
IS 6240 (2008) |
Hot rolled steel plate (Up To 6 Mm) sheet and strip for the manufacture of low pressure liquefiable gas cylinders (Fourth Revision) |
- |
-
|
- View breakup
Rs.9710/- excluding Erichsen cupping test.
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
Cl 7 (UTM) |
- |
|
|
|
Cl 8 (Press) |
- |
|
|
|
Cl 9 (Strainage Embrittlement) |
- |
|
|
|
Cl 13 (Length, Width & Thickness) |
- |
|
|
|
6.1 (Carbon %) |
- |
|
|
|
6.1 (Manganese %) |
- |
|
|
|
6.1 (Phosphorus %) |
- |
|
|
|
6.1 (Sulphur %) |
- |
|
|
|
6.1 (Silicon %) |
- |
|
|
|
6.1 (Nitrogen%) |
- |
|
|
|
|
Partial
|
|
- |
Excluding, Cupping Test, Microalloying elements |
150 |
IS 814 (2004) |
Covered electrodes for manual metal arc welding of carbon and carbon manganese steel - Specification (Sixth Revision) |
- |
-
|
Rs. 17500/- View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
7.1.1 (Diameter of Core Wire) |
- |
|
|
|
7.1.2 (Length of Electrodes) |
- |
|
|
|
7.2.1 (Contact End) |
- |
|
|
|
7.2.2 (Arc striking End) |
- |
|
|
|
7.3 (Concentricity of Flux covering with core wire) |
- |
|
|
|
9.1.2 Table 6 (Ultimate Tensile Strength-Annex F) |
- |
|
|
|
9.1.2 Table 6 ( Yield Stress -Annex F) |
- |
|
|
|
9.1.2 Table 6 (Percentage Elongation on Gauge Length-Annex F) |
- |
|
|
|
9.2 (Butt Weld Bend Test-IS 1599) |
- |
|
|
|
6 & 8.2 (Carbon- Relevant Parts of IS 228 or any other established instrumental/chemical method) |
- |
|
|
|
6 & 8.2 (Sulphur- Relevant Parts of IS 228 or any other established instrumental/chemical method) |
- |
|
|
|
6 & 8.2 (Silicon- Relevant Parts of IS 228 or any other established instrumental/chemical method) |
- |
|
|
|
6 & 8.2 (Manganese- Relevant Parts of IS 228 or any other established instrumental/chemical method) |
- |
|
|
|
6 & 8.2 (Phosphorous- Relevant Parts of IS 228 or any other established instrumental/chemical method) |
- |
|
|
|
|
Partial
|
|
- |
Radiographic test, increased metal recovery, diffusible hydrogen evaluation and For tensile and bend test prepared test pieces are required. Partial testing for Cl. 6 is available except Si and Microalloying elements. Test Facility as per Cl. 8.2 is not available |