| 361 |
QUALITY INTERNATIONAL RESEARCH & LABORATORIES PRIVATE LIMITED
| 5197006
| IS 5082 (1998) |
Wrought aluminium and aluminium alloy bars, rods, tubes, sections, plates and sheets for electrical applications (Second Revision) |
Wrought Aluminium & Aluminium Alloy Bars, Rods, Tubes, Sections, Plates & Sheets of Grade 19501 & 63401 |
14500 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 6.1(CHEMICAL COMPOSITION Table 1) |
- |
2500 |
|
- |
| Clause 5(FREEDOM FROM DEFECTS) |
- |
200 |
|
- |
| 8.1(MECHANICAL TEST
Tensile Strength Min, Mpa) |
- |
750 |
|
- |
| 8.1(MECHANICAL TEST
(0.2 Percent Proof Stress Min, Mpa)) |
- |
750 |
|
- |
| 8.1(Percent Elongation on 5.65 Min) |
- |
750 |
|
- |
| 8.2(Bend Test) |
- |
750 |
|
- |
| Clause 10(DIMENSIONAL TOLERANCES) |
- |
1000 |
|
- |
| 6.1, Table 1(Aluminium) |
- |
500 |
|
- |
| 6.1, Table 1(Copper) |
- |
500 |
|
- |
| 6.1, Table 1(Magnesium) |
- |
500 |
|
- |
| 6.1, Table 1(Silicon) |
- |
500 |
|
- |
| 6.1, Table 1(Manganese) |
- |
500 |
|
- |
| 6.1, Table 1(Zinc) |
- |
500 |
|
- |
| 6.1, Table 1(Titanium) |
- |
500 |
|
- |
| 6.1, Table 1(Chromium) |
- |
500 |
|
- |
| 6.1, Table 1(Iron) |
- |
500 |
|
- |
| 6.1, Table 1(Vanadium) |
- |
500 |
|
- |
| 8.1(Electrical Conductivity at 20°C,Min) |
- |
1500 |
|
- |
| 8.1(Maximum Electrical Resistivity at 20°C ohm-mm/mm2) |
- |
1500 |
|
- |
| 6.1(CHEMICAL COMPOSITION Table 1) |
- |
2500 |
|
- |
| Clause 5(FREEDOM FROM DEFECTS) |
- |
500 |
|
- |
| 8.1(MECHANICAL TEST
Tensile Strength Min, Mpa) |
- |
750 |
|
- |
| 8.1(MECHANICAL TEST
(0.2 Percent Proof Stress Min, Mpa)) |
- |
750 |
|
- |
| 8.1(Percent Elongation on 5.65 Min) |
- |
750 |
|
- |
| 8.2(Bend Test) |
- |
750 |
|
- |
| Clause 10(DIMENSIONAL TOLERANCES) |
- |
1000 |
|
- |
| 6.1, Table 1(Aluminium) |
- |
500 |
|
- |
| 6.1, Table 1(Copper) |
- |
500 |
|
- |
| 6.1, Table 1(Magnesium) |
- |
500 |
|
- |
| 6.1, Table 1(Silicon) |
- |
500 |
|
- |
| 6.1, Table 1(Manganese) |
- |
500 |
|
- |
| 6.1, Table 1(Zinc) |
- |
500 |
|
- |
| 6.1, Table 1(Titanium) |
- |
500 |
|
- |
| 6.1, Table 1(Chromium) |
- |
500 |
|
- |
| 6.1, Table 1(Iron) |
- |
500 |
|
- |
| 6.1, Table 1(Vanadium) |
- |
500 |
|
- |
| 8.1(Electrical Conductivity at 20°C,Min) |
- |
500 |
|
- |
| 8.1(Maximum Electrical Resistivity at 20°C ohm-mm/mm2) |
- |
500 |
|
- |
|
- |
- Included w.e.f. 02.03.2026 |
| 362 |
AANKAN CALIBRATION AND TESTING CENTRE LLP, DANTLI
| 7184406
| IS 15786 (2008) |
Prelaminated cement bonded particle board - Specification |
ALL |
32900 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Clause 10.3 (Moisture content) |
- |
600 |
|
IS 15786 physical tests-15500, Raw material cl. 5.2, 5.3, 5.4-3000, IS 14276 as per clause 5.1-14400 ) |
| 5.1(Cement Bonded Particle Board) |
- |
14400 |
|
- |
| 5.2(Impregnated Base Paper) |
- |
1000 |
|
- |
| 5.4(Finished Foil) |
- |
0 |
|
- |
| 6(Manufacture) |
- |
0 |
|
- |
| 7(Finish) |
- |
0 |
|
- |
| 8(DIMENSIONS AND TOLERANCES) |
- |
600 |
|
- |
| 10.2(Test for Density) |
- |
600 |
|
- |
| 10.4(Test for Water Absorption) |
- |
1200 |
|
- |
| 10.5(Test for Swelling in Water) |
- |
1000 |
|
- |
| 10.6(Test for Modulus of Elasticity and Modulus of Rupture) |
- |
1000 |
|
- |
| 10.7(Test for Tensile Strength Perpendicular to Surface) |
- |
1000 |
|
- |
| 10.8(Test for Tensile Strength Perpendicular to Surface After Ageing) |
- |
3000 |
|
- |
| 10.9(Test for Screw Withdrawal Strength) |
- |
2000 |
|
- |
| 10.10(Test for Abrasion Resistance) |
- |
1500 |
|
- |
| 10.11(Test for Resistance to Steam) |
- |
600 |
|
- |
| 10.12(Test for Resistance to Crack) |
- |
600 |
|
- |
| 10.13(Test for Resistance to Cigarette Bum) |
- |
600 |
|
- |
| 10.14(Test for Resistance to Stain) |
- |
600 |
|
- |
| 11(Marking) |
- |
0 |
|
- |
| 5.3(Impregnated OverlaylUnderIay) |
- |
1000 |
|
Complete Testing Charges IS-32900 (For IS 15786 physical tests-15500, Raw material cl. 5.2, 5.3, 5.4-3000, IS 14276 as per clause 5.1-14400 ) |
|
17 Mar, 2028 |
- Included w.e.f 01.04.2026 |
| 363 |
Stellar Test House, Noida
| 8171606
| IS 302 : PART 1 (Commercial Electric Rinsing Sinks) |
Commercial Electric Rinsing Sinks |
- |
30000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 6(Classifications) |
- |
500 |
|
- |
| 6(Classifications) |
- |
500 |
|
- |
| 5(General conditions for tests) |
- |
500 |
|
- |
| 4(General Requirement) |
- |
500 |
|
- |
| 11.8(Temperature rise) |
- |
1000 |
|
- |
| 11.7(Duration corresponding) |
- |
1000 |
|
- |
| 11.6(Combined appliances) |
- |
1000 |
|
- |
| 11.5(Motor-operated appliances) |
- |
1000 |
|
- |
| 11.4(Heating appliances) |
- |
1000 |
|
- |
| 8.1.5(Live parts of built-in appliances) |
- |
1000 |
|
- |
| 18(Endurance) |
- |
1000 |
|
- |
| 17(Overload protection of transformers and associated circuits) |
- |
1000 |
|
- |
| 16(Leakage current and electric strength) |
- |
1000 |
|
- |
| 4(General requirement) |
- |
500 |
|
- |
| 32(Radiation Toxicity and Similar Hazards) |
- |
1000 |
|
- |
| 31(Resistance to Rusting) |
- |
1000 |
|
- |
| 30.2(Needle Flame Test) |
- |
1000 |
|
- |
| 30.2(Glow Wire Test) |
- |
1000 |
|
- |
| 30.1(Ball pressure test) |
- |
1000 |
|
- |
| 29(clearance, creepage distances and solid insulation) |
- |
1000 |
|
- |
| 28(Screw test and connections) |
- |
1000 |
|
- |
| 27(Provision for earthing) |
- |
1000 |
|
- |
| 26(Terminals for external conductors) |
- |
1000 |
|
- |
| 25(Supply connection and external flexible cords) |
- |
1000 |
|
- |
| 24(Components) |
- |
1000 |
|
- |
| 23(General) |
- |
1000 |
|
- |
| 22(Construction verification related test) |
- |
1000 |
|
- |
| 21(Mechanical Strength Test) |
- |
1000 |
|
- |
| 20(Stability test) |
- |
1000 |
|
- |
| 19(Abnormal Operation) |
- |
1000 |
|
- |
| 18(Endurance Test requirements and tests) |
- |
1000 |
|
- |
| 17(Over Load Protection of Transformers and associated circuits) |
- |
1000 |
|
- |
| 16.3(Electric Strength (after clause 15 and 16.2)) |
- |
1000 |
|
- |
| 16.2(Leakage Current (after Clause 15)) |
- |
1000 |
|
- |
| 16.1(General) |
- |
1000 |
|
- |
| 16.0(General) |
- |
1000 |
|
- |
| 15.3(Humidity Test) |
- |
1000 |
|
- |
| 15.2(Spillage Test) |
- |
1000 |
|
- |
| 15.1(Ingress Protection test other than IPX0 (IP test)) |
- |
1000 |
|
- |
| 15.0(General) |
- |
1000 |
|
- |
| 14(Transient Over Voltages) |
- |
1000 |
|
- |
| 13.2(Leakage current at operating temperature) |
- |
1000 |
|
- |
| 13.1(General) |
- |
1000 |
|
- |
| 11.3(Heating) |
- |
1000 |
|
- |
| 11.2(General) |
- |
1000 |
|
- |
| 11.1(General) |
- |
1000 |
|
- |
| 10.2(Current input) |
- |
1000 |
|
- |
| 10.1(Power input) |
- |
1000 |
|
- |
| 9(Starting of motor operation test requirements and tests) |
- |
1000 |
|
- |
| 8.1.4(Protection against live parts against protective impedance) |
- |
1000 |
|
- |
| 8.1.3(Protection against live parts in visible glowing heating elements) |
- |
1000 |
|
- |
| 8.1.2(Protection against live parts in openings) |
- |
1000 |
|
- |
| 8.1.1(Protection against live parts in all positions) |
- |
1000 |
|
- |
| 7(Marking and instructions) |
- |
500 |
|
- |
| 13.3(Electric Strength at operating temperature) |
- |
1000 |
|
- |
|
26 Sep, 2028 |
- 1 19.11.4.7 (Harmonics) EMI/EMC Test Test facilities not available
2 19.11.4.6 (Class 3 Voltage dips and interruptions) EMI/EMC Test Test facilities not available
3 19.11.4.5 (Immunity to conducted discharges) EMI/EMC Test Test facilities not available
4 19.11.4.4 (Surge immunity test) EMI/EMC Test Test facilities not available
5 19.11.4.3 (Fast transient bursts) EMI/EMC Test Test facilities not available
6 19.11.4.2 (Radiated fields) EMI/EMC Test Test facilities not available
7 19.11.4.1 (Electrostatic discharges) EMI/EMC Test Test facilities not available. |
| 364 |
Stellar Test House, Noida
| 8171606
| IS 302 : PART 1 (Commercial Electric Multi-purpose Cooking Pans) |
Commercial Electric Multi-purpose Cooking Pans |
- |
30000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 6(Classifications) |
- |
500 |
|
- |
| 5(General conditions for tests) |
- |
500 |
|
- |
| 4(General Requirement) |
- |
500 |
|
- |
| 11.8(Temperature rise) |
- |
1000 |
|
- |
| 11.7(Duration corresponding) |
- |
1000 |
|
- |
| 11.6(Combined appliances) |
- |
1000 |
|
- |
| 11.5(Motor-operated appliances) |
- |
1000 |
|
- |
| 11.4(Heating appliances) |
- |
1000 |
|
- |
| 8.1.5(Live parts of built-in appliances) |
- |
1000 |
|
- |
| 18(Endurance) |
- |
1000 |
|
- |
| 17(Overload protection of transformers and associated circuits) |
- |
1000 |
|
- |
| 16(Leakage current and electric strength) |
- |
1000 |
|
- |
| 4(General requirement) |
- |
500 |
|
- |
| 32(Radiation Toxicity and Similar Hazards) |
- |
1000 |
|
- |
| 31(Resistance to Rusting) |
- |
1000 |
|
- |
| 30.2(Needle Flame Test) |
- |
1000 |
|
- |
| 30.2(Glow Wire Test) |
- |
1000 |
|
- |
| 30.1(Ball pressure test) |
- |
1000 |
|
- |
| 29(clearance, creepage distances and solid insulation) |
- |
1000 |
|
- |
| 28(Screw test and connections) |
- |
1000 |
|
- |
| 27(Provision for earthing) |
- |
1000 |
|
- |
| 26(Terminals for external conductors) |
- |
1000 |
|
- |
| 25(Supply connection and external flexible cords) |
- |
1000 |
|
- |
| 24(Components) |
- |
1000 |
|
- |
| 23(General) |
- |
1000 |
|
- |
| 22(Construction verification related test) |
- |
1000 |
|
- |
| 21(Mechanical Strength Test) |
- |
1000 |
|
- |
| 20(Stability test) |
- |
1000 |
|
- |
| 19(Abnormal Operation) |
- |
1000 |
|
- |
| 18(Endurance Test requirements and tests) |
- |
1000 |
|
- |
| 17(Over Load Protection of Transformers and associated circuits) |
- |
1000 |
|
- |
| 16.3(Electric Strength (after clause 15 and 16.2)) |
- |
1000 |
|
- |
| 16.2(Leakage Current (after Clause 15)) |
- |
1000 |
|
- |
| 16.1(General) |
- |
1000 |
|
- |
| 16.0(General) |
- |
1000 |
|
- |
| 15.3(Humidity Test) |
- |
1000 |
|
- |
| 15.2(Spillage Test) |
- |
1000 |
|
- |
| 15.1(Ingress Protection test other than IPX0 (IP test)) |
- |
1000 |
|
- |
| 15.0(General) |
- |
1000 |
|
- |
| 14(Transient Over Voltages) |
- |
1000 |
|
- |
| 13.3(Electric Strength at operating temperature) |
- |
1000 |
|
- |
| 13.2(Leakage current at operating temperature) |
- |
1000 |
|
- |
| 13.1(General) |
- |
1000 |
|
- |
| 11.3(Heating) |
- |
1000 |
|
- |
| 11.2(General) |
- |
1000 |
|
- |
| 11.1(General) |
- |
1000 |
|
- |
| 10.2(Current input) |
- |
1000 |
|
- |
| 10.1(Power input) |
- |
1000 |
|
- |
| 8.1.4(Protection against live parts against protective impedance) |
- |
1000 |
|
- |
| 8.1.3(Protection against live parts in visible glowing heating elements) |
- |
1000 |
|
- |
| 8.1.1(Protection against live parts in all positions) |
- |
1000 |
|
- |
| 7(Marking and instructions) |
- |
500 |
|
- |
| 9(Starting of motor operation test requirements and tests) |
- |
1000 |
|
- |
| 8.1.2(Protection against live parts in openings) |
- |
1000 |
|
- |
|
26 Sep, 2028 |
- 1 19.11.4.7 (Harmonics) EMI/EMC Test Test facilities not available
2 19.11.4.6 (Class 3 Voltage dips and interruptions) EMI/EMC Test Test facilities not available
3 19.11.4.5 (Immunity to conducted discharges) EMI/EMC Test Test facilities not available
4 19.11.4.4 (Surge immunity test) EMI/EMC Test Test facilities not available
5 19.11.4.3 (Fast transient bursts) EMI/EMC Test Test facilities not available
6 19.11.4.2 (Radiated fields) EMI/EMC Test Test facilities not available
7 19.11.4.1 (Electrostatic discharges) EMI/EMC Test Test facilities not available. |
| 365 |
AANKAN CALIBRATION AND TESTING CENTRE LLP, DANTLI
| 7184406
| IS 19267 (2025) |
Oriented Strand Boards � Specification |
all |
19500 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl-5.1(Wood) |
- |
0 |
|
- |
| Cl-5.2(Adhesives) |
- |
0 |
|
EXTRA |
| Cl-5.3(Preservative) |
- |
0 |
|
EXTRA |
| Cl-7(Finish) |
- |
500 |
|
- |
| Cl-8.1(Any dimensions (length and width)) |
- |
1000 |
|
- |
| Cl-8.2(Thickness) |
- |
500 |
|
- |
| Cl-8.3(Squareness and Edge Straightness) |
- |
1000 |
|
- |
| Cl-8.4(Tolerances) |
- |
1000 |
|
- |
| Cl-9.1, Table-2 (i)(Density variation within board, Max) |
- |
1000 |
|
- |
| Cl-9.1, Table-2 (ii)(Moisture content,) |
- |
1000 |
|
- |
| Cl-9.1, Table-3 (GP-REG) (i)(Modulus of rupture (MoR), N/mm2, Min — Major axis) |
- |
1500 |
|
- |
| Cl-9.1, Table-3 (GP-REG) (ii)(Modulus of rupture (MoR), N/mm2, Min — Minor axis) |
- |
1500 |
|
- |
| Cl-9.1, Table-3 (GP-REG) (iii)(Modulus of elasticity (MoE), N/mm2, Min — Major axis) |
- |
1500 |
|
- |
| Cl-9.1, Table-3 (GP-REG) (iv)(Modulus of elasticity (MoE), N/mm2, Min — Minor axis) |
- |
1500 |
|
- |
| Cl-9.1, Table-3 (GP-REG) (v)(Internal bond strength, N/mm2, Min) |
- |
2000 |
|
- |
| Cl-9.1, Table-3 (GP-REG) (vi)(24 h thickness swelling (due to general absorption), percent, Max) |
- |
1500 |
|
- |
| Cl-9.1, Table-3 (GP-REG) (vii)(Screw withdrawal strength (face), N, Min) |
- |
1500 |
|
- |
| Cl-9.1, Table-3 (GP-REG) (viii)(Screw withdrawal strength (edge), N, Min) |
- |
1500 |
|
- |
| Cl-9.1, Table-4 (LB-REG) (i)(Modulus of rupture (MoR), N/mm2, Min — Major axis) |
- |
1500 |
|
- |
| Cl-9.1, Table-4 (LB-REG) (ii)(Modulus of rupture (MoR), N/mm2, Min — Minor axis) |
- |
1500 |
|
- |
| Cl-9.1, Table-4 (LB-REG) (iii)(Modulus of elasticity (MoE), N/mm2, Min — Major axis) |
- |
1500 |
|
- |
| Cl-9.1, Table-4 (LB-REG) (iv)(Modulus of elasticity (MoE), N/mm2, Min — Minor axis) |
- |
1500 |
|
- |
| Cl-9.1, Table-4 (LB-REG) (v)(Internal bond strength, N/mm2, Min) |
- |
2000 |
|
- |
| Cl-9.1, Table-4 (LB-REG) (vi)(24 h thickness swelling (due to general absorption), percent, Max) |
- |
1500 |
|
- |
| Cl-9.1, Table-4 (LB-REG) (vii)(Screw withdrawal strength (face), N, Min) |
- |
1500 |
|
- |
| Cl-9.1, Table-4 (LB-REG) (viii)(Screw withdrawal strength (edge), N, Min) |
- |
1500 |
|
- |
| Cl-9.1, Table-5 (LB-MR) (i)(Modulus of rupture (MoR), N/mm2, Min — Major axis) |
- |
1500 |
|
- |
| Cl-9.1, Table-5 (LB-MR) (ii)(Modulus of rupture (MoR), N/mm2, Min — Minor axis) |
- |
1500 |
|
- |
| Cl-9.1, Table-5 (LB-MR) (iii)(Modulus of elasticity (MoE), N/mm2, Min — Major axis) |
- |
1500 |
|
- |
| Cl-9.1, Table-5 (LB-MR) (iv)(Modulus of elasticity (MoE), N/mm2, Min — Minor axis) |
- |
1500 |
|
- |
| Cl-9.1, Table-5 (LB-MR) (v)(Internal bond strength, N/mm2, Min) |
- |
2000 |
|
- |
| Cl-9.1, Table-5 (LB-MR) (vi)(24 h thickness swelling (due to general absorption), percent, Max) |
- |
1500 |
|
- |
| Cl-9.1, Table-5 (LB-MR) (vii)(Screw withdrawal strength (face), N, Min) |
- |
1500 |
|
- |
| Cl-9.1, Table-5 (LB-MR) (viii)(Screw withdrawal strength (edge), N, Min) |
- |
1500 |
|
- |
| Cl-9.1, Table-5 (LB-MR) (ix) (a)("Option1, Cyclic test:
(i) Internal bond Strength, N/mm2, Min") |
- |
2000 |
|
- |
| Cl-9.1, Table-5 (LB-MR) (ix) (b)("Option 2, Boil test:
(i) Internal bond strength, N/mm2, Min") |
- |
2000 |
|
- |
| Cl-9.1, Table-5 (LB-MR) (x)(Modulus of rupture after cyclic test, N/mm2— Major axis) |
- |
1500 |
|
- |
| Cl-9.1, Table-6 (HLB-MR) (i)(Modulus of rupture (MoR), N/mm2, Min — Major axis) |
- |
1500 |
|
- |
| Cl-9.1, Table-6 (HLB-MR) (ii)(Modulus of rupture (MoR), N/mm2, Min — Minor axis) |
- |
1500 |
|
- |
| Cl-9.1, Table-6 (HLB-MR) (iii)(Modulus of elasticity (MoE), N/mm2, Min — Major axis) |
- |
1500 |
|
- |
| Cl-9.1, Table-6 (HLB-MR) (iv)(Modulus of elasticity (MoE), N/mm2, Min — Minor axis) |
- |
1500 |
|
- |
| Cl-9.1, Table-6 (HLB-MR) (v)(Internal bond strength, N/mm2, Min) |
- |
2000 |
|
- |
| Cl-9.1, Table-6 (HLB-MR) (vi)(24 h thickness swelling (due to general absorption), percent, Max) |
- |
1500 |
|
- |
| Cl-9.1, Table-6 (HLB-MR) (vii)(Screw withdrawal strength (face),) |
- |
1500 |
|
- |
| Cl-9.1, Table-6 (HLB-MR) (viii)(Screw withdrawal strength (edge),) |
- |
1500 |
|
- |
| Cl-9.1, Table-6 (HLB-MR) (ix)("Option1, Cyclic test:
(i) Internal bond Strength, N/mm2, Min") |
- |
2000 |
|
- |
| Cl-9.1, Table-6 (HLB-MR) (ix)("Option 2, Boil test:
(i) Internal bond strength, N/mm2, Min") |
- |
2000 |
|
- |
| Cl-9.1, Table-6 (HLB-MR) (x)(Modulus of rupture after cyclic test, N/mm2 — Major axis) |
- |
1500 |
|
- |
| Cl-9.1, Table-7 (i)(Formaldehyde content Fc, mg/100 g for oven dry board) |
- |
3000 |
|
- |
| Cl-9.1, Table-7 (ii)(Steady-state formaldehyde emission, Fc, mg/m3) |
- |
0 |
|
- |
| Cl-11(Marking) |
- |
0 |
|
- |
|
17 Mar, 2028 |
- Included w.e.f 17.03.2026 |
| 366 |
JBS TESTING SOLUTIONS PVT LTD (27), JALANDHAR
| 9164606
| IS 4984 (2016) |
Polyethylene pipes for water supply - Specification (Fifth Revision) |
- |
26500 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 8.10(Slow Crack Growth Rate) |
- |
1000 |
|
- |
| 8.9 table-6(Elongation at Break) |
- |
1500 |
|
- |
| 8.8(Tensile Strength for Butt-fusion) |
- |
1500 |
|
- |
| 8.7(Density) |
- |
1000 |
|
- |
| 8.5 (Oxidation Induction Time) |
- |
2000 |
|
- |
| 8.4( Melt Flow Rate) |
- |
1500 |
|
- |
| 8.2(Longitudinal Reversion Test) |
- |
1000 |
|
- |
| 8.1.2 table -5(Internal Pressure Creep Rupture Test of Pipe Joints) |
- |
2000 |
|
- |
| 8,/8.1/8.1.1 table-5(PERFORMANCE REQUIREMENTS / Hydraulic Characteristics/ Internal Pressure Creep Rupture Test of Pipe) |
- |
2000 |
|
- |
| 7.4.1.2(Ovality) |
- |
200 |
|
- |
| Cl-7.4(Mean Outside Diameter (For upto 50 mm take 8 reading, above 50mm take 6 reading & average will be reported)) |
- |
200 |
|
- |
| 7.2(Length) |
- |
200 |
|
- |
| 6.2.1(6.1.1 Identification Stripes) |
- |
200 |
|
- |
| 6.2(Colour) |
- |
200 |
|
- |
| 6.1.4(PIPE DESCRIPTION) |
- |
200 |
|
- |
| 6.1.3 (PIPE DESCRIPTION) |
- |
200 |
|
- |
| 6, 6.1.2(PIPE DESCRIPTION) |
- |
200 |
|
- |
| 6, 6.1.1(PIPE DESCRIPTION) |
- |
200 |
|
- |
| 6, 6.1(PIPE DESCRIPTION) |
- |
200 |
|
- |
| 8.6(Overall migration) |
- |
2000 |
|
- |
| 8.3(Carbon black) |
- |
1000 |
|
- |
| 5.4(Anti oxydent) |
- |
0 |
|
EXCLUSION REQUESTED |
| 5.3(e)(Carbon Black Master Batch) |
- |
0 |
|
EXCLUSION REQUESTED |
| 5.3(d)(Carbon Black Master Batch) |
- |
2500 |
|
- |
| 5.3(c)(Carbon Black Master Batch) |
- |
2000 |
|
- |
| 5.3(b)(Carbon Black Master Batch) |
- |
0 |
|
EXCLUSION REQUESTED |
| 5.3 (a)(Carbon Black Master Batch) |
- |
2000 |
|
- |
| 5.2(Polyethylene Resin) |
- |
2000 |
|
- |
| 5, 5.1 table-1(MATERIALS) |
- |
200 |
|
- |
| 7() |
- |
500 |
|
- |
| 5.2(Density) |
- |
1000 |
|
- |
| 5.2(MFI @ 1900C/5.0 Kg) |
- |
1000 |
|
- |
| 5.2(Volatile matter Content) |
- |
1000 |
|
- |
| 5.3(Toluene Extract) |
- |
1000 |
|
- |
| Clause 7.1(Visual Apperance) |
- |
200 |
|
- |
| Clause 7.3(Coiling) |
- |
200 |
|
- |
| Clause 8.3(Carbon Black content) |
- |
1500 |
|
- |
| Clause 8.3(Carbon Black Dispersion) |
- |
1000 |
|
- |
| Clause 8.6(Overall migration (stimulate)) |
- |
2000 |
|
- |
| Clause 8.6(Overall migration (surface of material)) |
- |
2000 |
|
- |
| 7.1(Visual Appearance) |
- |
200 |
|
- |
| 7.3(Coiling) |
- |
200 |
|
- |
| Table-2 (iii, iv)(Thermal Stability (Oxidation Induction Time), Volatile Matter) |
- |
2500 |
|
- |
| Cl. 8.3(Carbon Black Content) |
- |
1500 |
|
- |
| Cl. 8.3(Carbon Black Dispersion) |
- |
1000 |
|
- |
| 5.2,T2(Melt Flow rate(Temperature - 190oC,Mass 5kg)-IS 2530-1963) |
- |
1500 |
|
- |
| 8.7(Density-IS 7328:2020) |
- |
1000 |
|
- |
| 8.7(Corrected Density- IS 7328:2020) |
- |
500 |
|
- |
| 8.9,T6("Tensile - IS 4984-2016
(Annexure-H)") |
- |
2500 |
|
- |
| 8.9,T6("Elongation -IS 4984-2016
(Annexure-H)") |
- |
2500 |
|
- |
| Cl 8.3(Carbon Black Content) |
- |
1000 |
|
- |
| Cl 8.3(Carbon Black Dispersion) |
- |
1000 |
|
- |
| CL 7.4(Wall Thickness (Take 8 reading & Minimum and Maximum reported)) |
- |
1000 |
|
- |
| 8.10(Slow Crack Growth Rate) |
- |
0 |
|
- |
| Cl-7.4(Mean Outside Diameter (For upto 50 mm take 8 reading, above 50mm take 6 reading & average will be reported)) |
- |
0 |
|
- |
| 7() |
- |
0.03 |
|
- |
| 5.2(Density) |
- |
0 |
|
- |
| 5.2(MFI @ 1900C/5.0 Kg) |
- |
0.03 |
|
- |
| 5.2(Volatile matter Content) |
- |
0 |
|
- |
| 5.3(Toluene Extract) |
- |
0.03 |
|
- |
| Clause 7.1(Visual Apperance) |
- |
0 |
|
- |
| Clause 7.3(Coiling) |
- |
0 |
|
- |
| Clause 8.3(Carbon Black content) |
- |
0 |
|
- |
| Clause 8.3(Carbon Black Dispersion) |
- |
0 |
|
- |
| Clause 8.6(Overall migration (stimulate)) |
- |
0 |
|
- |
| Clause 8.6(Overall migration (surface of material)) |
- |
0 |
|
- |
| 7.1(Visual Appearance) |
- |
0 |
|
- |
| 7.3(Coiling) |
- |
0.02 |
|
- |
| Table-2 (iii, iv)(Thermal Stability (Oxidation Induction Time), Volatile Matter) |
- |
0 |
|
- |
| Cl. 8.3(Carbon Black Content) |
- |
0 |
|
- |
| Cl. 8.3(Carbon Black Dispersion) |
- |
0 |
|
- |
| 5.2,T2(Melt Flow rate(Temperature - 190oC,Mass 5kg)-IS 2530-1963) |
- |
0 |
|
- |
| 8.7(Density-IS 7328:2020) |
- |
0.03 |
|
- |
| 8.7(Corrected Density- IS 7328:2020) |
- |
0.03 |
|
- |
| 8.9,T6("Tensile - IS 4984-2016
(Annexure-H)") |
- |
0.02 |
|
- |
| 8.9,T6("Elongation -IS 4984-2016
(Annexure-H)") |
- |
0.02 |
|
- |
| Cl 8.3(Carbon Black Content) |
- |
0 |
|
- |
| Cl 8.3(Carbon Black Dispersion) |
- |
0 |
|
- |
| CL 7.4(Wall Thickness (Take 8 reading & Minimum and Maximum reported)) |
- |
0 |
|
- |
|
- |
- 1.
5.4 (Anti oxydent) anti-oxydent 5.4 (Anti oxydent), 5.3(b) (Carbon Black Master Batch), 5.3 (Toluene Extract), Cl 5.2 Table 2 Sl No V Water content, Cl 5.3(a) Higher Olefin constituent additional requirement.
2.
5.3(b) (Carbon Black Master Batch) Carbon black master batch 5.4 (Anti oxydent), 5.3(b) (Carbon Black Master Batch), 5.3 (Toluene Extract), Cl 5.2 Table 2 Sl No V Water content, Cl 5.3(a) Higher Olefin constituent additional requirement.
3.
5.3(e) (Carbon Black Master Batch) carbon black master batch 5.4 (Anti oxydent), 5.3(b) (Carbon Black Master Batch), 5.3 (Toluene Extract), Cl 5.2 Table 2 Sl No V Water content, Cl 5.3(a) Higher Olefin constituent additional requirement. |
| 367 |
Nemko India (Test Lab) Pvt. Ltd., Faridabad
| 8138426
| IS 302 : Part 2 : Sec 3 (2024) |
Household and Similar Electrical Appliances âSafety Part 2 Particular Requirements Section 3 Electric Irons (Second Revision) |
- |
240000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl-4(General requirement) |
- |
0 |
|
-- |
| Cl-7(Marking and instructions) |
- |
1000 |
|
10% (Discount offered to BIS) |
| Cl-8(Protection against access to live parts) |
- |
4000 |
|
10% (Discount offered to BIS) |
| Cl-10(Power input and current) |
- |
5000 |
|
10% (Discount offered to BIS) |
| Cl-11(Heating) |
- |
5000 |
|
10% (Discount offered to BIS) |
| Cl-12(Charging of metal-ion batteries) |
- |
2000 |
|
10% (Discount offered to BIS) |
| Cl-13(Leakage current and electric strength at operating temperature) |
- |
2000 |
|
10% (Discount offered to BIS) |
| Cl-14(Transient overvoltages) |
- |
2000 |
|
10% (Discount offered to BIS) |
| Cl-15(Moisture resistance) |
- |
10000 |
|
10% (Discount offered to BIS) |
| Cl-16(Leakage current and electric strength) |
- |
3000 |
|
10% (Discount offered to BIS) |
| Cl-17(Overload protection of transformers and associated circuits) |
- |
2000 |
|
10% (Discount offered to BIS) |
| Cl-18(Endurance) |
- |
1000 |
|
10% (Discount offered to BIS) |
| Cl-19(Abnormal operation) |
- |
9000 |
|
10% (Discount offered to BIS) |
| Cl-20(Stability and mechanical hazards) |
- |
2000 |
|
10% (Discount offered to BIS) |
| Cl-21(Mechanical strength) |
- |
2000 |
|
10% (Discount offered to BIS) |
| Cl-22(Construction) |
- |
4000 |
|
10% (Discount offered to BIS) |
| Cl-23(Internal wiring) |
- |
2000 |
|
10% (Discount offered to BIS) |
| Cl-25(Supply connection and external flexible cords) |
- |
2000 |
|
10% (Discount offered to BIS) |
| Cl-26(Terminals for external conductors) |
- |
2000 |
|
10% (Discount offered to BIS) |
| Cl-27(Provision for earthing) |
- |
4000 |
|
10% (Discount offered to BIS) |
| Cl-28(Screws and connections) |
- |
2000 |
|
10% (Discount offered to BIS) |
| Cl-29(Clearances, creepage distances and solid insulation) |
- |
3000 |
|
10% (Discount offered to BIS) |
| Cl-30(Resistance to heat and fire) |
- |
8000 |
|
10% (Discount offered to BIS) |
| Cl-31(Resistance to rusting) |
- |
2000 |
|
10% (Discount offered to BIS) |
| Cl-19.11.4.1(Electrostatic discharges) |
- |
20000 |
|
10% (Discount offered to BIS) |
| Cl-19.11.4.2(Radiated fields) |
- |
40000 |
|
10% (Discount offered to BIS) |
| Cl-19.11.4.3(Fast transient bursts) |
- |
15000 |
|
10% (Discount offered to BIS) |
| Cl-19.11.4.4(Surge immunity test) |
- |
15000 |
|
10% (Discount offered to BIS) |
| Cl-19.11.4.5(Immunity to conducted discharges) |
- |
20000 |
|
10% (Discount offered to BIS) |
| Cl-19.11.4.6(Class 3 Voltage dips and interruptions) |
- |
20000 |
|
10% (Discount offered to BIS) |
| Cl-19.11.4.7(Harmonics) |
- |
40000 |
|
10% (Discount offered to BIS) |
| Cl-4(General requirement) |
- |
0 |
|
-- |
| Cl-7(Marking and instructions) |
- |
0 |
|
-- |
| Cl-8(Protection against access to live parts) |
- |
0 |
|
-- |
| Cl-10(Power input and current) |
- |
0 |
|
-- |
| Cl-11(Heating) |
- |
0 |
|
-- |
| Cl-12(Charging of metal-ion batteries) |
- |
0 |
|
-- |
| Cl-13(Leakage current and electric strength at operating temperature) |
- |
0 |
|
-- |
| Cl-14(Transient overvoltages) |
- |
0 |
|
-- |
| Cl-15(Moisture resistance) |
- |
0 |
|
-- |
| Cl-16(Leakage current and electric strength) |
- |
0 |
|
-- |
| Cl-17(Overload protection of transformers and associated circuits) |
- |
0 |
|
-- |
| Cl-18(Endurance) |
- |
0 |
|
-- |
| Cl-19(Abnormal operation) |
- |
0 |
|
-- |
| Cl-20(Stability and mechanical hazards) |
- |
0 |
|
-- |
| Cl-21(Mechanical strength) |
- |
0 |
|
-- |
| Cl-22(Construction) |
- |
0 |
|
-- |
| Cl-23(Internal wiring) |
- |
0 |
|
-- |
| Cl-25(Supply connection and external flexible cords) |
- |
0 |
|
-- |
| Cl-26(Terminals for external conductors) |
- |
0 |
|
-- |
| Cl-27(Provision for earthing) |
- |
0 |
|
-- |
| Cl-28(Screws and connections) |
- |
0 |
|
-- |
| Cl-29(Clearances, creepage distances and solid insulation) |
- |
0 |
|
-- |
| Cl-30(Resistance to heat and fire) |
- |
0 |
|
-- |
| Cl-31(Resistance to rusting) |
- |
0 |
|
-- |
| Cl-19.11.4.1(Electrostatic discharges) |
- |
0 |
|
-- |
| Cl-19.11.4.2(Radiated fields) |
- |
0 |
|
-- |
| Cl-19.11.4.3(Fast transient bursts) |
- |
0 |
|
-- |
| Cl-19.11.4.4(Surge immunity test) |
- |
0 |
|
00 |
| Cl-19.11.4.5(Immunity to conducted discharges) |
- |
0 |
|
-- |
| Cl-19.11.4.6(Class 3 Voltage dips and interruptions) |
- |
0 |
|
-- |
| Cl-19.11.4.7(Harmonics) |
- |
0 |
|
-- |
| Cl-4(General requirement) |
- |
0 |
|
- |
| Cl-7(Marking and instructions) |
- |
0 |
|
- |
| Cl-8(Protection against access to live parts) |
- |
0 |
|
- |
| Cl-10(Power input and current) |
- |
0 |
|
- |
| Cl-11(Heating) |
- |
0 |
|
- |
| Cl-12(Charging of metal-ion batteries) |
- |
0 |
|
- |
| Cl-13(Leakage current and electric strength at operating temperature) |
- |
0 |
|
- |
| Cl-14(Transient overvoltages) |
- |
0 |
|
- |
| Cl-15(Moisture resistance) |
- |
0 |
|
- |
| Cl-16(Leakage current and electric strength) |
- |
0 |
|
- |
| Cl-17(Overload protection of transformers and associated circuits) |
- |
0 |
|
- |
| Cl-18(Endurance) |
- |
0 |
|
- |
| Cl-19(Abnormal operation) |
- |
0 |
|
- |
| Cl-20(Stability and mechanical hazards) |
- |
0 |
|
- |
| Cl-21(Mechanical strength) |
- |
0 |
|
- |
| Cl-22(Construction) |
- |
0 |
|
- |
| Cl-23(Internal wiring) |
- |
0 |
|
- |
| Cl-25(Supply connection and external flexible cords) |
- |
0 |
|
- |
| Cl-26(Terminals for external conductors) |
- |
0 |
|
- |
| Cl-27(Provision for earthing) |
- |
0 |
|
- |
| Cl-28(Screws and connections) |
- |
0 |
|
- |
| Cl-29(Clearances, creepage distances and solid insulation) |
- |
0 |
|
- |
| Cl-30(Resistance to heat and fire) |
- |
0 |
|
- |
| Cl-31(Resistance to rusting) |
- |
0 |
|
- |
| Cl-19.11.4.1(Electrostatic discharges) |
- |
0 |
|
- |
| Cl-19.11.4.2(Radiated fields) |
- |
0 |
|
- |
| Cl-19.11.4.3(Fast transient bursts) |
- |
0 |
|
- |
| Cl-19.11.4.4(Surge immunity test) |
- |
0 |
|
- |
| Cl-19.11.4.5(Immunity to conducted discharges) |
- |
0 |
|
- |
| Cl-19.11.4.6(Class 3 Voltage dips and interruptions) |
- |
0 |
|
- |
| Cl-19.11.4.7(Harmonics) |
- |
0 |
|
- |
| Cl-4(General requirement) |
- |
0 |
|
- |
| Cl-7(Marking and instructions) |
- |
0 |
|
- |
| Cl-8(Protection against access to live parts) |
- |
0 |
|
- |
| Cl-10(Power input and current) |
- |
0 |
|
- |
| Cl-11(Heating) |
- |
0 |
|
- |
| Cl-12(Charging of metal-ion batteries) |
- |
0 |
|
- |
| Cl-13(Leakage current and electric strength at operating temperature) |
- |
0 |
|
- |
| Cl-14(Transient overvoltages) |
- |
0 |
|
- |
| Cl-15(Moisture resistance) |
- |
0 |
|
- |
| Cl-16(Leakage current and electric strength) |
- |
0 |
|
- |
| Cl-17(Overload protection of transformers and associated circuits) |
- |
0 |
|
- |
| Cl-18(Endurance) |
- |
0 |
|
- |
| Cl-19(Abnormal operation) |
- |
0 |
|
- |
| Cl-20(Stability and mechanical hazards) |
- |
0 |
|
- |
| Cl-21(Mechanical strength) |
- |
0 |
|
- |
| Cl-22(Construction) |
- |
0 |
|
- |
| Cl-23(Internal wiring) |
- |
0 |
|
- |
| Cl-25(Supply connection and external flexible cords) |
- |
0 |
|
- |
| Cl-26(Terminals for external conductors) |
- |
0 |
|
- |
| Cl-27(Provision for earthing) |
- |
0 |
|
- |
| Cl-28(Screws and connections) |
- |
0 |
|
- |
| Cl-29(Clearances, creepage distances and solid insulation) |
- |
0 |
|
- |
| Cl-30(Resistance to heat and fire) |
- |
0 |
|
- |
| Cl-31(Resistance to rusting) |
- |
0 |
|
- |
| Cl-19.11.4.1(Electrostatic discharges) |
- |
0 |
|
- |
| Cl-19.11.4.2(Radiated fields) |
- |
0 |
|
- |
| Cl-19.11.4.3(Fast transient bursts) |
- |
0 |
|
- |
| Cl-19.11.4.4(Surge immunity test) |
- |
0 |
|
- |
| Cl-19.11.4.5(Immunity to conducted discharges) |
- |
0 |
|
- |
| Cl-19.11.4.6(Class 3 Voltage dips and interruptions) |
- |
0 |
|
- |
| Cl-19.11.4.7(Harmonics) |
- |
0 |
|
- |
| Cl-4(General requirement) |
- |
0 |
|
- |
| Cl-7(Marking and instructions) |
- |
0 |
|
- |
| Cl-8(Protection against access to live parts) |
- |
0 |
|
- |
| Cl-10(Power input and current) |
- |
0 |
|
- |
| Cl-11(Heating) |
- |
0 |
|
- |
| Cl-12(Charging of metal-ion batteries) |
- |
0 |
|
- |
| Cl-13(Leakage current and electric strength at operating temperature) |
- |
0 |
|
- |
| Cl-14(Transient overvoltages) |
- |
0 |
|
- |
| Cl-15(Moisture resistance) |
- |
0 |
|
- |
| Cl-16(Leakage current and electric strength) |
- |
0 |
|
- |
| Cl-17(Overload protection of transformers and associated circuits) |
- |
0 |
|
- |
| Cl-18(Endurance) |
- |
0 |
|
- |
| Cl-19(Abnormal operation) |
- |
0 |
|
- |
| Cl-20(Stability and mechanical hazards) |
- |
0 |
|
- |
| Cl-21(Mechanical strength) |
- |
0 |
|
- |
| Cl-22(Construction) |
- |
0 |
|
- |
| Cl-23(Internal wiring) |
- |
0 |
|
- |
| Cl-25(Supply connection and external flexible cords) |
- |
0 |
|
- |
| Cl-26(Terminals for external conductors) |
- |
0 |
|
- |
| Cl-27(Provision for earthing) |
- |
0 |
|
- |
| Cl-28(Screws and connections) |
- |
0 |
|
- |
| Cl-29(Clearances, creepage distances and solid insulation) |
- |
0 |
|
- |
| Cl-30(Resistance to heat and fire) |
- |
0 |
|
- |
| Cl-31(Resistance to rusting) |
- |
0 |
|
- |
| Cl-19.11.4.1(Electrostatic discharges) |
- |
0 |
|
- |
| Cl-19.11.4.2(Radiated fields) |
- |
0 |
|
- |
| Cl-19.11.4.3(Fast transient bursts) |
- |
0 |
|
- |
| Cl-19.11.4.4(Surge immunity test) |
- |
0 |
|
- |
| Cl-19.11.4.5(Immunity to conducted discharges) |
- |
0 |
|
- |
| Cl-19.11.4.6(Class 3 Voltage dips and interruptions) |
- |
0 |
|
- |
| Cl-19.11.4.7(Harmonics) |
- |
0 |
|
- |
|
31 Dec, 2026 |
- Included w.e.f 01.04.2026
Exclusion: Cl-24 (Components), Cl-32 (Radiation, toxicity and similar hazards) |
| 368 |
Stellar Test House, Noida
| 8171606
| IS 302 : PART 1 (Commercial Electric Boiling Pans) |
Commercial Electric Boiling Pans |
- |
30000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 6(Classifications) |
- |
500 |
|
- |
| 5(General conditions for tests) |
- |
500 |
|
- |
| 4(General Requirement) |
- |
500 |
|
- |
| 11.8(Temperature rise) |
- |
1000 |
|
- |
| 11.7(Duration corresponding) |
- |
1000 |
|
- |
| 11.6(Combined appliances) |
- |
1000 |
|
- |
| 11.5(Motor-operated appliances) |
- |
1000 |
|
- |
| 11.4(Heating appliances) |
- |
1000 |
|
- |
| 8.1.5(Live parts of built-in appliances) |
- |
1000 |
|
- |
| 18(Endurance) |
- |
1000 |
|
- |
| 17(Overload protection of transformers and associated circuits) |
- |
1000 |
|
- |
| 16(Leakage current and electric strength) |
- |
1000 |
|
- |
| 4(General requirement) |
- |
1000 |
|
- |
| 32(Radiation Toxicity and Similar Hazards) |
- |
1000 |
|
- |
| 31(Resistance to Rusting) |
- |
1000 |
|
- |
| 30.2(Needle Flame Test) |
- |
1000 |
|
- |
| 30.2(Glow Wire Test) |
- |
1000 |
|
- |
| 30.1(Ball pressure test) |
- |
1000 |
|
- |
| 29(clearance, creepage distances and solid insulation) |
- |
1000 |
|
- |
| 28(Screw test and connections) |
- |
1000 |
|
- |
| 27(Provision for earthing) |
- |
1000 |
|
- |
| 26(Terminals for external conductors) |
- |
1000 |
|
- |
| 25(Supply connection and external flexible cords) |
- |
1000 |
|
- |
| 24(Components) |
- |
1000 |
|
- |
| 23(General) |
- |
1000 |
|
- |
| 22(Construction verification related test) |
- |
1000 |
|
- |
| 21(Mechanical Strength Test) |
- |
1000 |
|
- |
| 20(Stability test) |
- |
1000 |
|
- |
| 19(Abnormal Operation) |
- |
1000 |
|
- |
| 18(Endurance Test requirements and tests) |
- |
1000 |
|
- |
| 17(Over Load Protection of Transformers and associated circuits) |
- |
1000 |
|
- |
| 16.3(Electric Strength (after clause 15 and 16.2)) |
- |
1000 |
|
- |
| 16.2(Leakage Current (after Clause 15)) |
- |
1000 |
|
- |
| 16.1(General) |
- |
1000 |
|
- |
| 16.0(General) |
- |
1000 |
|
- |
| 15.3(Humidity Test) |
- |
1000 |
|
- |
| 15.2(Spillage Test) |
- |
1000 |
|
- |
| 15.1(Ingress Protection test other than IPX0 (IP test)) |
- |
1000 |
|
- |
| 15.0(General) |
- |
1000 |
|
- |
| 14(Transient Over Voltages) |
- |
1000 |
|
- |
| 13.3(Electric Strength at operating temperature) |
- |
1000 |
|
- |
| 13.2(Leakage current at operating temperature) |
- |
1000 |
|
- |
| 13.1(General) |
- |
1000 |
|
- |
| 11.3(Heating) |
- |
1000 |
|
- |
| 11.2(General) |
- |
1000 |
|
- |
| 11.1(General) |
- |
1000 |
|
- |
| 10.2(Current input) |
- |
1000 |
|
- |
| 10.1(Power input) |
- |
1000 |
|
- |
| 9(Starting of motor operation test requirements and tests) |
- |
1000 |
|
- |
| 8.1.4(Protection against live parts against protective impedance) |
- |
1000 |
|
- |
| 8.1.3(Protection against live parts in visible glowing heating elements) |
- |
1000 |
|
- |
| 8.1.2(Protection against live parts in openings) |
- |
1000 |
|
- |
| 8.1.1(Protection against live parts in all positions) |
- |
1000 |
|
- |
| 7(Marking and instructions) |
- |
500 |
|
- |
|
26 Sep, 2028 |
- "1 19.11.4.7 (Harmonics) EMI/EMC Test Test facilities not available
2 19.11.4.6 (Class 3 Voltage dips and interruptions) EMI/EMC Test Test facilities not available
3 19.11.4.5 (Immunity to conducted discharges) EMI/EMC Test Test facilities not available
4 19.11.4.3 (Fast transient bursts) EMI/EMC Test Test facilities not available
5 19.11.4.2 (Radiated fields) EMI/EMC Test Test facilities not available
6 19.11.4.1 (Electrostatic discharges) EMI/EMC Test Test facilities not available
7 19.11.4.4 (Surge immunity test) EMI/EMC Test Test facilities not available" |
| 369 |
JBS TESTING SOLUTIONS PVT LTD (27), JALANDHAR
| 9164606
| IS 10748 (2025) |
Hot-Rolled Steel Strip for Welded Tubes and Pipes - Specification ( Third Revision) |
- |
14000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl-4(Supply of Materials) |
- |
14000 |
|
- |
|
- |
- - |
| 370 |
Stellar Test House, Noida
| 8171606
| IS 302 : PART 1 (Commercial Electric Grillers and Toasters) |
Commercial Electric Grillers and Toasters |
- |
30000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 6(Classifications) |
- |
500 |
|
- |
| 5(General conditions for tests) |
- |
500 |
|
- |
| 4(General Requirement) |
- |
500 |
|
- |
| 11.8(Temperature rise) |
- |
1000 |
|
- |
| 11.7(Duration corresponding) |
- |
1000 |
|
- |
| 11.6(Combined appliances) |
- |
1000 |
|
- |
| 11.5(Motor-operated appliances) |
- |
1000 |
|
- |
| 11.4(Heating appliances) |
- |
1000 |
|
- |
| 8.1.5(Live parts of built-in appliances) |
- |
1000 |
|
- |
| 18(Endurance) |
- |
1000 |
|
- |
| 17(Overload protection of transformers and associated circuits) |
- |
1000 |
|
- |
| 16(Leakage current and electric strength) |
- |
1000 |
|
- |
| 4(General requirement) |
- |
500 |
|
- |
| 32(Radiation Toxicity and Similar Hazards) |
- |
1000 |
|
- |
| 31(Resistance to Rusting) |
- |
1000 |
|
- |
| 30.2(Needle Flame Test) |
- |
1000 |
|
- |
| 30.2(Glow Wire Test) |
- |
1000 |
|
- |
| 30.1(Ball pressure test) |
- |
1000 |
|
- |
| 29(clearance, creepage distances and solid insulation) |
- |
1000 |
|
- |
| 28(Screw test and connections) |
- |
1000 |
|
- |
| 27(Provision for earthing) |
- |
1000 |
|
- |
| 26(Terminals for external conductors) |
- |
1000 |
|
- |
| 25(Supply connection and external flexible cords) |
- |
1000 |
|
- |
| 24(Components) |
- |
1000 |
|
- |
| 23(General) |
- |
1000 |
|
- |
| 22(Construction verification related test) |
- |
1000 |
|
- |
| 21(Mechanical Strength Test) |
- |
1000 |
|
- |
| 20(Stability test) |
- |
1000 |
|
- |
| 19(Abnormal Operation) |
- |
1000 |
|
- |
| 18(Endurance Test requirements and tests) |
- |
1000 |
|
- |
| 17(Over Load Protection of Transformers and associated circuits) |
- |
1000 |
|
- |
| 16.3(Electric Strength (after clause 15 and 16.2)) |
- |
1000 |
|
- |
| 16.2(Leakage Current (after Clause 15)) |
- |
1000 |
|
- |
| 16.1(General) |
- |
1000 |
|
- |
| 16.0(General) |
- |
1000 |
|
- |
| 15.3(Humidity Test) |
- |
1000 |
|
- |
| 15.2(Spillage Test) |
- |
1000 |
|
- |
| 15.1(Ingress Protection test other than IPX0 (IP test)) |
- |
1000 |
|
- |
| 15.0(General) |
- |
1000 |
|
- |
| 14(Transient Over Voltages) |
- |
1000 |
|
- |
| 13.3(Electric Strength at operating temperature) |
- |
1000 |
|
- |
| 13.2(Leakage current at operating temperature) |
- |
1000 |
|
- |
| 13.1(General) |
- |
1000 |
|
- |
| 11.3(Heating) |
- |
1000 |
|
- |
| 11.2(General) |
- |
1000 |
|
- |
| 11.1(General) |
- |
1000 |
|
- |
| 10.2(Current input) |
- |
1000 |
|
- |
| 10.1(Power input) |
- |
1000 |
|
- |
| 9(Starting of motor operation test requirements and tests) |
- |
1000 |
|
- |
| 8.1.4(Protection against live parts against protective impedance) |
- |
1000 |
|
- |
| 8.1.3(Protection against live parts in visible glowing heating elements) |
- |
1000 |
|
- |
| 8.1.2(Protection against live parts in openings) |
- |
1000 |
|
- |
| 8.1.1(Protection against live parts in all positions) |
- |
1000 |
|
- |
| 7(Marking and instructions) |
- |
500 |
|
- |
|
26 Sep, 2028 |
- "1 19.11.4.7 (Harmonics) EMI/EMC Test Test facilities not available
2 19.11.4.6 (Class 3 Voltage dips and interruptions) EMI/EMC Test Test facilities not available
3 19.11.4.5 (Immunity to conducted discharges) EMI/EMC Test Test facilities not available
4 19.11.4.4 (Surge immunity test) EMI/EMC Test Test facilities not available
5 19.11.4.3 (Fast transient bursts) EMI/EMC Test Test facilities not available
6 19.11.4.2 (Radiated fields) EMI/EMC Test Test facilities not available
7 19.11.4.1 (Electrostatic discharges) EMI/EMC Test Test facilities not available" |
| 371 |
AJEO TESTING LABS PVT LTD, GHAZIABAD
| 8178606
| IS 863 (2023) |
Medical Textiles - Cotton bandage cloth - Specification third revision of IS 863 |
- |
3500 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4.1(Fibre Identification) |
- |
300 |
|
10% DISCOUNT FOR BIS |
| 4.2, Table 1, i)(Count of yarn (for guidance only)) |
- |
300 |
|
10% DISCOUNT FOR BIS |
| 4.2, Table 1, ii)(Threads, dm, Min) |
- |
200 |
|
10% DISCOUNT FOR BIS |
| 4.2, Table 1, iii)(Mass, g/m2) |
- |
300 |
|
10% DISCOUNT FOR BIS |
| 4.2, Table 1, iv)(Length, m, tolerance) |
- |
100 |
|
10% DISCOUNT FOR BIS |
| 4.2, Table 1, v)(Width, m, tolerance) |
- |
100 |
|
10% DISCOUNT FOR BIS |
| 4.2, Table 1, vi)(pH value of acqueous extract) |
- |
300 |
|
10% DISCOUNT FOR BIS |
| 4.2, Table 1, vii)(Scouring loss, percent, Max) |
- |
300 |
|
10% DISCOUNT FOR BIS |
| 4.2, Table 1, viii)(Freedom from optical whiteners) |
- |
200 |
|
10% DISCOUNT FOR BIS |
| 4.2, Table 1, ix)(Colour fastness: a) Light) |
- |
800 |
|
10% DISCOUNT FOR BIS |
| 4.2, Table 1, ix)(Colour fastness: b) Washing (A1)) |
- |
300 |
|
10% DISCOUNT FOR BIS |
| 6(Marking) |
- |
300 |
|
10% DISCOUNT FOR BIS |
| 4.3(Cleanliness–Microbial/Bioburden Test) |
- |
0 |
|
- |
| 4.1(Fibre Identification) |
- |
0 |
|
REPEAT |
| 4.2, Table 1, i)(Count of yarn (for guidance only)) |
- |
0 |
|
REPEAT |
| 4.2, Table 1, ii)(Threads, dm, Min) |
- |
0 |
|
REPEAT |
| 4.2, Table 1, iii)(Mass, g/m2) |
- |
0 |
|
REPEAT |
| 4.2, Table 1, iv)(Length, m, tolerance) |
- |
0 |
|
REPEAT |
| 4.2, Table 1, v)(Width, m, tolerance) |
- |
0 |
|
REPEAT |
| 4.2, Table 1, vi)(pH value of acqueous extract) |
- |
0 |
|
REPEAT |
| 4.2, Table 1, vii)(Scouring loss, percent, Max) |
- |
0 |
|
REPEAT |
| 4.2, Table 1, viii)(Freedom from optical whiteners) |
- |
0 |
|
REPEAT |
| 4.2, Table 1, ix)(Colour fastness: a) Light) |
- |
0 |
|
REPEAT |
| 4.2, Table 1, ix)(Colour fastness: b) Washing (A1)) |
- |
0 |
|
REPEAT |
| 6(Marking) |
- |
0 |
|
REPEAT |
| 4.3(Cleanliness–Microbial/Bioburden Test) |
- |
0 |
|
REPEAT |
| 4.1(Fibre Identification) |
- |
- |
|
- |
| 4.2, Table 1, i)(Count of yarn (for guidance only)) |
- |
- |
|
- |
| 4.2, Table 1, ii)(Threads, dm, Min) |
- |
- |
|
- |
| 4.2, Table 1, iii)(Mass, g/m2) |
- |
- |
|
- |
| 4.2, Table 1, iv)(Length, m, tolerance) |
- |
- |
|
- |
| 4.2, Table 1, v)(Width, m, tolerance) |
- |
- |
|
- |
| 4.2, Table 1, vi)(pH value of acqueous extract) |
- |
- |
|
- |
| 4.2, Table 1, vii)(Scouring loss, percent, Max) |
- |
- |
|
- |
| 4.2, Table 1, viii)(Freedom from optical whiteners) |
- |
- |
|
- |
| 4.2, Table 1, ix)(Colour fastness: a) Light) |
- |
- |
|
- |
| 4.2, Table 1, ix)(Colour fastness: b) Washing (A1)) |
- |
- |
|
- |
| 6(Marking) |
- |
- |
|
- |
| 4.3(Cleanliness–Microbial/Bioburden Test) |
- |
- |
|
- |
|
- |
- Included w.e.f 17.03.2026
Exclusion: 4.2, Table 1, x) (Sterility (optional)) |
| 372 |
JBS TESTING SOLUTIONS PVT LTD (27), JALANDHAR
| 9164606
| IS 12701 (1996) |
Rotational moulded polyethylene water storage tanks - specification (First Revision) |
- |
21000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4.2.3(Carbon Black Content ) |
- |
2000 |
|
- |
| 4.2.3(Carbon Dispersion Test) |
- |
2000 |
|
- |
| 5(Types and Features ) |
- |
1500 |
|
- |
| 5.1 Table 1(Dimensioas of Cylinderical Vertical Tank) |
- |
1500 |
|
- |
| 5.1 Table 1(Dimensioas of Cylinderical Vertical Tank) |
- |
1500 |
|
- |
| 5.1 Table 1(Dimensioas of Cylinderical Vertical Tank) |
- |
1500 |
|
- |
| 5.1 Table 1(Dimensioas of Cylinderical Vertical Tank) |
- |
1500 |
|
- |
| 5.1 Table 1(Dimensioas of Cylinderical Vertical Tank) |
- |
1500 |
|
- |
| 5.1 Table 1(Dimensioas of Cylinderical Vertical Tank) |
- |
1500 |
|
- |
| 5.1 Table 1(Dimensioas of Cylinderical Vertical Tank) |
- |
1500 |
|
- |
| 5.1 Table 1(Dimensioas of Cylinderical Vertical Tank) |
- |
1500 |
|
- |
| 5.2 Table 2(Dimensions of Rectangular Loft Tanks) |
- |
1500 |
|
- |
| 5.2 Table 2(Dimensions of Rectangular Loft Tanks) |
- |
1500 |
|
- |
| 5.2 Table 2(Dimensions of Rectangular Loft Tanks) |
- |
1500 |
|
- |
| 5.2 Table 2(Dimensions of Rectangular Loft Tanks) |
- |
1500 |
|
- |
| 5.2 Table 2(Dimensions of Rectangular Loft Tanks) |
- |
1500 |
|
- |
| 5.2 Table 2(Dimensions of Rectangular Loft Tanks) |
- |
1500 |
|
- |
| 5.2 Table 2(Dimensions of Rectangular Loft Tanks) |
- |
1500 |
|
- |
| 5.2 Table 2(Dimensions of Rectangular Loft Tanks) |
- |
1500 |
|
- |
| 5.3(Types and Features ) |
- |
1500 |
|
- |
| 5.6(Types and Features ) |
- |
1500 |
|
- |
| 6.1(Finish) |
- |
500 |
|
- |
| 7.1.1(Resistance to Deformation) |
- |
1000 |
|
- |
| 7.1.2(Resistance to Deformation) |
- |
2000 |
|
- |
| 7.2(Resistance to Impact) |
- |
3000 |
|
- |
| 7.3(Test for Top Load Resistance) |
- |
3000 |
|
- |
| 7.4(Tensile Strength) |
- |
5500 |
|
- |
| 7.5(Flexural Modulus) |
- |
5500 |
|
- |
| 7.6(overall Migration) |
- |
5500 |
|
- |
| 9.2.1(Man-Hole and Hand-Hole Lids) |
- |
5500 |
|
- |
| 9.2(Man-Hole and Hand-Hole Lids) |
- |
1000 |
|
- |
| 9.1(Man-Hole and Hand-Hole Lids) |
- |
1000 |
|
- |
| 9.1(Lid Thickness) |
- |
1000 |
|
- |
| 7.3(Test for Top Load Resistance) |
- |
3000 |
|
- |
| 6.1(Finish) |
- |
500 |
|
- |
| 5.4(Wall Thickness above effective height) |
- |
1500 |
|
- |
| 5.2 Table 2 (7)(Minimum Wall Thickness) |
- |
1500 |
|
- |
| 5.1 Table 1 (7)(Minimum Weight of Tank (Without Lid)) |
- |
1500 |
|
- |
| 4.2.1(Density) |
- |
500 |
|
- |
| 4.2.2(MFI) |
- |
500 |
|
- |
| 7.6(overall Migration) |
- |
500 |
|
- |
| 4.1(MATERIALS) |
- |
500 |
|
- |
| 4.2.2(MFR) |
- |
500 |
|
- |
| 4.2.1(Density) |
- |
500 |
|
- |
| 5.4(Wall Thickness) |
- |
500 |
|
- |
| 10(MARKING) |
- |
500 |
|
- |
| Cl-7.6(Overall Migration) |
- |
500 |
|
- |
|
- |
- Included w.e.f. 02.03.2026 |
| 373 |
JBS TESTING SOLUTIONS (Unit-2) (24), Jalandhar
| 9172306
| IS 456 (2000) |
Plain and reinforced concrete - Code of practice (Fourth Revision) |
For Compression and Construction water |
4000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 5.4-Table-1 (v)-IS: 3025(P-17)(Suspended matter) |
- |
4000 |
|
For compressive strength: 4000
For construction water: 6500 |
| 5.4-Table-1 (iv)-IS: 3025(P-32)(Chloride) |
- |
4000 |
|
For compressive strength: 4000
For construction water: 6500 |
| 5.4-Table-1 (iii)-IS: 3025(P-32)(Chloride) |
- |
4000 |
|
For compressive strength: 4000
For construction water: 6500 |
| 5.4-Table-1 (ii)-IS: 3025(P-24)(Sulphate) |
- |
4000 |
|
For compressive strength: 4000
For construction water: 6500 |
| 5.4-Table-1 (i)-IS: 3025(P-18)(In-Organic) |
- |
4000 |
|
For compressive strength: 4000
For construction water: 6500 |
| 5.4-Table-1 (i)-IS: 3025(P-18)(Organic ) |
- |
4000 |
|
For compressive strength: 4000
For construction water: 6500 |
| 5.4.2-IS: 3025(P-11)(Ph) |
- |
4000 |
|
For compressive strength: 4000
For construction water: 6500 |
| 5.4-(b)-IS: 3025 (P-23)(Volume of 0.02 N H2SO4 to neutralized 100 ml of water using mixed indicator) |
- |
4000 |
|
For compressive strength: 4000
For construction water: 6500 |
| 5.4-(a)-IS: 3025 (P-22)(Volume of 0.02 N NaOH to neutralized 100 ml of water using phenolphthalein indicator) |
- |
4000 |
|
For compressive strength: 4000
For construction water: 6500 |
| Cl 5.4 Table 1 (v)(Suspended Matter) |
- |
4000 |
|
For compressive strength: 4000
For construction water: 6500 |
| Cl 5.4 Table 1 (iv)(Chloride) |
- |
4000 |
|
For compressive strength: 4000
For construction water: 6500 |
| Cl 5.4 Table 1 (iii)(Sulphate) |
- |
4000 |
|
For compressive strength: 4000
For construction water: 6500 |
| Cl 5.4 Table 1 (ii)(Inorganic Solids) |
- |
4000 |
|
For compressive strength: 4000
For construction water: 6500 |
| Cl 5.4 Table 1 (i)(Organic Solids) |
- |
4000 |
|
For compressive strength: 4000
For construction water: 6500 |
| Cl 5.4 .2(pH) |
- |
4000 |
|
For compressive strength: 4000
For construction water: 6500 |
| Cl 5.4 (b)(Alkalinity) |
- |
4000 |
|
For compressive strength: 4000
For construction water: 6500 |
| Cl 5.4 (a)(Acidity) |
- |
4000 |
|
For compressive strength: 4000
For construction water: 6500 |
| 16.1(Average Compressive Strength) |
- |
4000 |
|
For compressive strength: 4000
For construction water: 6500 |
| 16.1(Compressive Strength of Individual Samples ) |
- |
4000 |
|
For compressive strength: 4000
For construction water: 6500 |
| 16.1(Compressive Strength of Individual Samples ) |
- |
4000 |
|
For compressive strength: 4000
For construction water: 6500 |
| 16.1(Compressive Strength of Individual Samples ) |
- |
4000 |
|
For compressive strength: 4000
For construction water: 6500 |
| Clause 5.4(Description) |
- |
0 |
|
- |
| 5.2(Mineral Admixtures) |
- |
0 |
|
- |
| 5.3(Aggregates) |
- |
0 |
|
- |
| 5.7(Storage of Materials) |
- |
0 |
|
- |
|
22 May, 2029 |
- - |
| 374 |
Stellar Test House, Noida
| 8171606
| IS 302 : PART 1 (Outdoor Barbecues) |
Outdoor Barbecues |
- |
30000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 6(Classifications) |
- |
500 |
|
- |
| 5(General conditions for tests) |
- |
500 |
|
- |
| 4(General Requirement) |
- |
500 |
|
- |
| 11.8(Temperature rise) |
- |
1000 |
|
- |
| 11.7(Duration corresponding) |
- |
1000 |
|
- |
| 11.6(Combined appliances) |
- |
1000 |
|
- |
| 11.5(Motor-operated appliances) |
- |
1000 |
|
- |
| 11.4(Heating appliances) |
- |
1000 |
|
- |
| 8.1.5(Live parts of built-in appliances) |
- |
1000 |
|
- |
| 18(Endurance) |
- |
1000 |
|
- |
| 17(Overload protection of transformers and associated circuits) |
- |
1000 |
|
- |
| 16(Leakage current and electric strength) |
- |
1000 |
|
- |
| 4(General requirement) |
- |
500 |
|
- |
| 32(Radiation Toxicity and Similar Hazards) |
- |
1000 |
|
- |
| 31(Resistance to Rusting) |
- |
1000 |
|
- |
| 30.2(Needle Flame Test) |
- |
1000 |
|
- |
| 30.2(Glow Wire Test) |
- |
1000 |
|
- |
| 30.1(Ball pressure test) |
- |
1000 |
|
- |
| 29(clearance, creepage distances and solid insulation) |
- |
1000 |
|
- |
| 28(Screw test and connections) |
- |
1000 |
|
- |
| 27(Provision for earthing) |
- |
1000 |
|
- |
| 26(Terminals for external conductors) |
- |
1000 |
|
- |
| 25(Supply connection and external flexible cords) |
- |
1000 |
|
- |
| 24(Components) |
- |
1000 |
|
- |
| 23(General) |
- |
1000 |
|
- |
| 22(Construction verification related test) |
- |
1000 |
|
- |
| 21(Mechanical Strength Test) |
- |
1000 |
|
- |
| 20(Stability test) |
- |
1000 |
|
- |
| 19(Abnormal Operation) |
- |
1000 |
|
- |
| 18(Endurance Test requirements and tests) |
- |
1000 |
|
- |
| 17(Over Load Protection of Transformers and associated circuits) |
- |
1000 |
|
- |
| 16.3(Electric Strength (after clause 15 and 16.2)) |
- |
1000 |
|
- |
| 16.2(Leakage Current (after Clause 15)) |
- |
1000 |
|
- |
| 16.1(General) |
- |
1000 |
|
- |
| 16.0(General) |
- |
1000 |
|
- |
| 15.3(Humidity Test) |
- |
1000 |
|
- |
| 15.2(Spillage Test) |
- |
1000 |
|
- |
| 15.1(Ingress Protection test other than IPX0 (IP test)) |
- |
1000 |
|
- |
| 15.0(General) |
- |
1000 |
|
- |
| 14(Transient Over Voltages) |
- |
1000 |
|
- |
| 13.3(Electric Strength at operating temperature) |
- |
1000 |
|
- |
| 13.2(Leakage current at operating temperature) |
- |
1000 |
|
- |
| 13.1(General) |
- |
1000 |
|
- |
| 11.3(Heating) |
- |
1000 |
|
- |
| 11.2(General) |
- |
1000 |
|
- |
| 11.1(General) |
- |
1000 |
|
- |
| 10.2(Current input) |
- |
1000 |
|
- |
| 10.1(Power input) |
- |
1000 |
|
- |
| 9(Starting of motor operation test requirements and tests) |
- |
1000 |
|
- |
| 8.1.4(Protection against live parts against protective impedance) |
- |
1000 |
|
- |
| 8.1.3(Protection against live parts in visible glowing heating elements) |
- |
1000 |
|
- |
| 8.1.2(Protection against live parts in openings) |
- |
1000 |
|
- |
| 8.1.1(Protection against live parts in all positions) |
- |
1000 |
|
- |
| 7(Marking and instructions) |
- |
500 |
|
- |
|
26 Sep, 2028 |
- "1 19.11.4.7 (Harmonics) EMI/EMC Test Test facilities not available
2 19.11.4.6 (Class 3 Voltage dips and interruptions) EMI/EMC Test Test facilities not available
3 19.11.4.5 (Immunity to conducted discharges) EMI/EMC Test Test facilities not available
4 19.11.4.4 (Surge immunity test) EMI/EMC Test Test facilities not available
5 19.11.4.3 (Fast transient bursts) EMI/EMC Test Test facilities not available
6 19.11.4.2 (Radiated fields) EMI/EMC Test Test facilities not available
7 19.11.4.1 (Electrostatic discharges) EMI/EMC Test Test facilities not available" |
| 375 |
Atckon Laboratories LLP, Bahadurgarh
| 8186436
| IS 6419 (1996) |
Welding rods and bare electrodes for gas shielded arc welding of structural steel - Specification (First Revision) |
ALL |
18300 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 5(Diameter) |
- |
18300 |
|
- |
| 6(Reels for Wire) |
- |
18300 |
|
- |
| 7(Reeling Condition) |
- |
18300 |
|
- |
| 8(Dimension of Spools, Rims & Coils) |
- |
18300 |
|
- |
| 14.1 Table 7(Sulphur-Relevant parts of IS 228) |
- |
18300 |
|
- |
| 9(Lengthof Rods) |
- |
18300 |
|
- |
| 10.1(Finish) |
- |
18300 |
|
- |
| 10.1(Copper Content of Coated Wire or Rod) |
- |
18300 |
|
- |
| 10.2.1 Table 5(Tensile Strength-IS 1608(P-1)) |
- |
18300 |
|
- |
| 10.2.2 Table 6(Cast- As per Cl.10.2.2 ) |
- |
18300 |
|
- |
| 10.2.3 Table 6(Helix- As per Cl.10.2.3 ) |
- |
18300 |
|
- |
| 14.1 Table 7(Carbon-Relevant parts of IS 228) |
- |
18300 |
|
- |
| 14.1 Table 7(Manganese-Relevant parts of IS 228) |
- |
18300 |
|
- |
| 14.1 Table 7(Silicon-Relevant parts of IS 228) |
- |
18300 |
|
- |
| 14.1 Table 7(Phosphorous-Relevant parts of IS 228) |
- |
18300 |
|
- |
| 14.1 Table 7(Nickel-Relevant parts of IS 228) |
- |
18300 |
|
- |
| 14.1 Table 7(Chromium-Relevant parts of IS 228) |
- |
18300 |
|
- |
| 14.1 Table 7(Molybdenum-Relevant parts of IS 228) |
- |
18300 |
|
- |
| 14.1 Table 7(Vanadium-Relevant parts of IS 228) |
- |
18300 |
|
- |
| 14.1 Table 7(Copper-Relevant parts of IS 228) |
- |
18300 |
|
- |
| 14.1 Table 7(Titanium-Relevant parts of IS 228) |
- |
18300 |
|
- |
| 14.1 Table 7(Zirconium-Relevant parts of IS 228) |
- |
18300 |
|
- |
| 14.1 Table 7(Aluminium-Relevant parts of IS 228) |
- |
18300 |
|
- |
| 14.1 Table 7(Mo+Ni+Cr-Relevant parts of IS 228) |
- |
18300 |
|
- |
| 10.2.1(Welding rods and bare electrodes for gas shielded arc welding of structural steel) |
- |
18300 |
|
- |
| 14.3.2(UTS) |
- |
18300 |
|
- |
| 14.3.2(Yield Stress) |
- |
18300 |
|
- |
| 14.3.2(% of Elongation) |
- |
18300 |
|
- |
| 14.3.3(Impact Test) |
- |
18300 |
|
- |
|
19 Jun, 2028 |
- - |
| 376 |
JBS TESTING SOLUTIONS (Unit-2) (24), Jalandhar
| 9172306
| IS 383 (2016) |
Coarse and Fine Aggregate for Concrete - Specification (Third Revision) |
- |
12000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 5.4.1 (a)(mechanical properties- Aggregate Crushing Value/Ten Percent Fines Value) |
- |
12000 |
|
- |
| 5.4.1 (b)(mechanical properties- Aggregate Crushing Value/Ten Percent Fines Value) |
- |
12000 |
|
- |
| 5.4.2(a)( Aggregates Impact Value) |
- |
12000 |
|
- |
| 5.4.2(b)( Aggregates Impact Value) |
- |
12000 |
|
- |
| 5.4.3(a)( Aggregate Abrasion Value) |
- |
12000 |
|
- |
| 5.4.3(b)( Aggregate Abrasion Value) |
- |
12000 |
|
- |
| 6.1-Table 7(SIZE AND GRADING OF AGGREGATES-Single-Sized Coarse Aggregates-Nominal Size of aggregate) |
- |
12000 |
|
- |
| 6.1-Table 7(i)(SIZE AND GRADING OF AGGREGATES-Single-Sized Coarse Aggregates-Percentage Passing through 80 mm sieve ) |
- |
12000 |
|
- |
| 6.1-Table 7(ii)(SIZE AND GRADING OF AGGREGATES-Single-Sized Coarse Aggregates-Percentage Passing through 63 mm sieve ) |
- |
12000 |
|
- |
| 6.1-Table 7(iii)(SIZE AND GRADING OF AGGREGATES-Single-Sized Coarse Aggregates-Percentage Passing through 40 mm sieve ) |
- |
12000 |
|
- |
| 6.1-Table 7(iv)(SIZE AND GRADING OF AGGREGATES-Single-Sized Coarse Aggregates-Percentage Passing through 20 mm sieve ) |
- |
12000 |
|
- |
| 6.1-Table 7(v)(SIZE AND GRADING OF AGGREGATES-Single-Sized Coarse Aggregates-Percentage Passing through 16 mm sieve ) |
- |
12000 |
|
- |
| 6.1-Table 7(vi)(SIZE AND GRADING OF AGGREGATES-Single-Sized Coarse Aggregates-Percentage Passing through 12.5 mm sieve ) |
- |
12000 |
|
- |
| 6.1-Table 7(vii)(SIZE AND GRADING OF AGGREGATES-Single-Sized Coarse Aggregates-Percentage Passing through 10 mm sieve ) |
- |
12000 |
|
- |
| 6.1-Table 7(viii)(SIZE AND GRADING OF AGGREGATES-Single-Sized Coarse Aggregates-Percentage Passing through 4.75 mm sieve ) |
- |
12000 |
|
- |
| 6.1-Table 7(ix)(SIZE AND GRADING OF AGGREGATES-Single-Sized Coarse Aggregates-Percentage Passing through 2.36 mm sieve ) |
- |
12000 |
|
- |
| 6.1.1-Table 8(SIZE AND GRADING OF AGGREGATES- Sizes of Coarse Aggregates for Mass Concrete- Class) |
- |
12000 |
|
- |
| 6.1.1-Table 8(SIZE AND GRADING OF AGGREGATES- Sizes of Coarse Aggregates for Mass Concrete- Size) |
- |
12000 |
|
- |
| 6.1.1-Table 8(i)(SIZE AND GRADING OF AGGREGATES- Sizes of Coarse Aggregates for Mass Concrete- Percentage Passing through 160 mm Sieve) |
- |
12000 |
|
- |
| 6.1.1-Table 8(i)(SIZE AND GRADING OF AGGREGATES- Sizes of Coarse Aggregates for Mass Concrete- Percentage Passing through 80 mm Sieve) |
- |
12000 |
|
- |
| 6.1.1-Table 8(ii)(SIZE AND GRADING OF AGGREGATES- Sizes of Coarse Aggregates for Mass Concrete- Percentage Passing through 80 mm Sieve) |
- |
12000 |
|
- |
| 6.1.1-Table 8(ii)(SIZE AND GRADING OF AGGREGATES- Sizes of Coarse Aggregates for Mass Concrete- Percentage Passing through 40 mm Sieve) |
- |
12000 |
|
- |
| 6.1.1-Table 8(iii)(SIZE AND GRADING OF AGGREGATES- Sizes of Coarse Aggregates for Mass Concrete- Percentage Passing through 40 mm Sieve) |
- |
12000 |
|
- |
| 6.1.1-Table 8(iii)(SIZE AND GRADING OF AGGREGATES- Sizes of Coarse Aggregates for Mass Concrete- Percentage Passing through 20 mm Sieve) |
- |
12000 |
|
- |
| 6.1.1-Table 8(iv)(SIZE AND GRADING OF AGGREGATES- Sizes of Coarse Aggregates for Mass Concrete- Percentage Passing through 20 mm Sieve) |
- |
12000 |
|
- |
| 6.1.1-Table 8(iv)(SIZE AND GRADING OF AGGREGATES- Sizes of Coarse Aggregates for Mass Concrete- Percentage Passing through 4.75 mm Sieve) |
- |
12000 |
|
- |
| 6.1.1-Table 8(iv)(SIZE AND GRADING OF AGGREGATES- Sizes of Coarse Aggregates for Mass Concrete- Percentage Passing through 2.36 mm Sieve) |
- |
12000 |
|
- |
| 6.2-Table 7(SIZE AND GRADING OF AGGREGATES- Graded Coarse Aggregates-Nominal Size of aggregate) |
- |
12000 |
|
- |
| 6.2-Table 7(i)(SIZE AND GRADING OF AGGREGATES- Graded Coarse Aggregates-Percentage Passing through 80 mm sieve) |
- |
12000 |
|
- |
| 6.2-Table 7(ii)(SIZE AND GRADING OF AGGREGATES- Graded Coarse Aggregates-Percentage Passing through 63 mm sieve) |
- |
12000 |
|
- |
| 6.2-Table 7(iii)(SIZE AND GRADING OF AGGREGATES- Graded Coarse Aggregates-Percentage Passing through 40 mm sieve) |
- |
12000 |
|
- |
| 6.2-Table 7(iv)(SIZE AND GRADING OF AGGREGATES- Graded Coarse Aggregates-Percentage Passing through 20 mm sieve) |
- |
12000 |
|
- |
| 6.2-Table 7(v)(SIZE AND GRADING OF AGGREGATES- Graded Coarse Aggregates-Percentage Passing through 16 mm sieve) |
- |
12000 |
|
- |
| 6.2-Table 7(vi)(SIZE AND GRADING OF AGGREGATES- Graded Coarse Aggregates-Percentage Passing through 12.5 mm sieve) |
- |
12000 |
|
- |
| 6.2-Table 7(vii)(SIZE AND GRADING OF AGGREGATES- Graded Coarse Aggregates-Percentage Passing through 10 mm sieve) |
- |
12000 |
|
- |
| 6.2-Table 7(viii)(SIZE AND GRADING OF AGGREGATES- Graded Coarse Aggregates-Percentage Passing through 4.75 mm sieve) |
- |
12000 |
|
- |
| 6.2-Table 7(ix)(SIZE AND GRADING OF AGGREGATES- Graded Coarse Aggregates-Percentage Passing through 2.36 mm sieve) |
- |
12000 |
|
- |
| 6.3-Table 9(SIZE AND GRADING OF AGGREGATES-Fine Aggregate-Grading Zone) |
- |
12000 |
|
- |
| 6.3-Table 9(i)(SIZE AND GRADING OF AGGREGATES-Fine Aggregate-Percentage Passing through 10mm Sieve ) |
- |
12000 |
|
- |
| 6.3-Table 9(ii)(SIZE AND GRADING OF AGGREGATES-Fine Aggregate-Percentage Passing through 4.75mm Sieve ) |
- |
12000 |
|
- |
| 6.3-Table 9(iii)(SIZE AND GRADING OF AGGREGATES-Fine Aggregate-Percentage Passing through 2.36mm Sieve ) |
- |
12000 |
|
- |
| 6.3-Table 9(iv)(SIZE AND GRADING OF AGGREGATES-Fine Aggregate-Percentage Passing through 1.18mm Sieve ) |
- |
12000 |
|
- |
| 6.3-Table 9(v)(SIZE AND GRADING OF AGGREGATES-Fine Aggregate-Percentage Passing through 600µm Sieve ) |
- |
12000 |
|
- |
| 6.3-Table 9(vi)(SIZE AND GRADING OF AGGREGATES-Fine Aggregate-Percentage Passing through 300µm Sieve ) |
- |
12000 |
|
- |
| 6.3-Table 9(vii)(SIZE AND GRADING OF AGGREGATES-Fine Aggregate-Percentage Passing through 150µm Sieve ) |
- |
12000 |
|
- |
| 6.4-Table 10(SIZE AND GRADING OF AGGREGATES- All-in-Aggregate Grading-Nominal Size ) |
- |
12000 |
|
- |
| 6.4-Table 10(i)(SIZE AND GRADING OF AGGREGATES- All-in-Aggregate Grading-Percentage Passing through 80mm Sieve ) |
- |
12000 |
|
- |
| 6.4-Table 10(ii)(SIZE AND GRADING OF AGGREGATES- All-in-Aggregate Grading-Percentage Passing through 40mm Sieve ) |
- |
12000 |
|
- |
| 6.4-Table 10(iii)(SIZE AND GRADING OF AGGREGATES- All-in-Aggregate Grading-Percentage Passing through 20mm Sieve ) |
- |
12000 |
|
- |
| 6.4-Table 10(iv)(SIZE AND GRADING OF AGGREGATES- All-in-Aggregate Grading-Percentage Passing through 4.75mm Sieve ) |
- |
12000 |
|
- |
| 6.4-Table 10(v)(SIZE AND GRADING OF AGGREGATES- All-in-Aggregate Grading-Percentage Passing through 600µm Sieve ) |
- |
12000 |
|
- |
| 6.4-Table 10(vi)(SIZE AND GRADING OF AGGREGATES- All-in-Aggregate Grading-Percentage Passing through 150µm Sieve ) |
- |
12000 |
|
- |
| 5.7-Table-3-(v) IS: 2386 (P-3)(specific gravity(fine aggregate)) |
- |
12000 |
|
- |
| 5.7-Table-3-(Iv) IS: 2386 (P-3)(Water absorption (fine aggregate)) |
- |
12000 |
|
- |
| 5.7-Table-3-(III) IS:14959 (P-2)(Water soluble chloride content (fine aggregate)) |
- |
12000 |
|
- |
| 5.7-Table-3-(II) IS:4032(Total sulphate content (fine aggregate)) |
- |
12000 |
|
- |
| 5.6-IS: 2386 (P-7)(Alkali Aggregate Reaction (fine aggregate)) |
- |
12000 |
|
- |
| 5.5-IS: 2386 (P-5)(Soundness (fine aggregate)) |
- |
12000 |
|
- |
| 5.2- TABLE-2- (Note-3) IS-2386 (P-2)(Mica content (fine aggregate)) |
- |
12000 |
|
- |
| 5.2- TABLE-2- (Note-4) IS-2386 (P-2)(Effect of organic impurities on strength of mortar (fine aggregate)) |
- |
12000 |
|
- |
| 5.2- TABLE-2- (Note-4) IS-2386 (P-2)(Effect of organic impurities on strength of mortar (fine aggregate)) |
- |
12000 |
|
- |
| 5.2- TABLE-2- (Note-4) IS-2386 (P-2)(Organic impurities (fine aggregate)) |
- |
12000 |
|
- |
| 5.2- TABLE-2- (vi) IS-2386 (P-2)(Total deleterious material (fine aggregate)) |
- |
12000 |
|
- |
| 5.2- TABLE-2- (iii) IS-2386 (P-1)(Material fine aggregater than 75 micron (fine aggregate)) |
- |
12000 |
|
- |
| 5.2- TABLE-2- (ii) IS-2386 (P-2)(Clay lumps (fine aggregate )) |
- |
12000 |
|
- |
| 5.2- TABLE-2- (i) IS-2386 (P-2)(Coal and Lignite (fine aggregate )) |
- |
12000 |
|
- |
| 5.7-Table-3-(v) IS: 2386 (P-3)(specific gravity(coarse aggregate)) |
- |
12000 |
|
- |
| 5.7-Table-3-(Iv) IS: 2386 (P-3)(Water absorption (coarse aggregate)) |
- |
12000 |
|
- |
| 5.7-Table-3-(III) BN EN: 1744(Water soluble chloride content (coarse aggregate)) |
- |
12000 |
|
- |
| 5.7-Table-3-(II) BN EN: 1744(Total sulphate content (coarse aggregate)) |
- |
12000 |
|
- |
| 5.6-IS: 2386 (P-7)(Alkali Aggregate Reaction (coarse aggregate)) |
- |
12000 |
|
- |
| 5.5-IS: 2386 (P-5)(Soundness (coarse aggregate)) |
- |
12000 |
|
- |
| 5.3-IS: 2386 (P-1)(Combined elongation & flakiness index (coarse aggregate)) |
- |
12000 |
|
- |
| 5.2- TABLE-2- (vi) IS-2386 (P-2)(Total deleterious material (coarse aggregate)) |
- |
12000 |
|
- |
| 5.2- TABLE-2- (iv) IS-2386 (P-2)(Soft fragments (coarse aggregate)) |
- |
12000 |
|
- |
| 5.2- TABLE-2- (iii) IS-2386 (P-1)(Material fine aggregater than 75 micron (coarse aggregate)) |
- |
12000 |
|
- |
| 5.2- TABLE-2- (ii) IS-2386 (P-2)(Clay lumps (coarse aggregate )) |
- |
12000 |
|
- |
| 5.2- TABLE-2- (i) IS-2386 (P-2)(Coal and Lignite (coarse aggregate )) |
- |
12000 |
|
- |
| 5.5(Soundness By Magnesium Sulphate) |
- |
12000 |
|
- |
| 7.2(Moisture Content) |
- |
12000 |
|
- |
| 7.2(Bulking Of Fine Aggregate) |
- |
12000 |
|
- |
| 7.2(Bulk Density loose) |
- |
12000 |
|
- |
| 7.2(Bulk Density Rodded) |
- |
12000 |
|
- |
| 5.5(Soundness By Magnesium Sulphate) |
- |
12000 |
|
- |
| 7.2(Moisture Content) |
- |
12000 |
|
- |
| 7.2(Bulk Density loose) |
- |
12000 |
|
- |
| 7.2(Bulk Density Rodded) |
- |
12000 |
|
- |
| 5.3(Elongation Index) |
- |
12000 |
|
- |
| 5.3(Flakiness Index) |
- |
12000 |
|
- |
| 5.6(Alkali Agregate Reaction ) |
- |
12000 |
|
- |
| 5.7 table 3(WaterAbsorption) |
- |
12000 |
|
- |
| 5.7 table 3(Specific Gravity) |
- |
12000 |
|
- |
| 5.3(Flakiness & Elongation) |
- |
12000 |
|
- |
| 5.5 Na2so4/5.5.1 Maso4/5.5.1 (Soundness) |
- |
12000 |
|
- |
| 5.7 table 4 (Calcium oxide) |
- |
12000 |
|
- |
| 5.5 Na2so4/5.5.1 Maso4/5.5.1 (Soundness) |
- |
12000 |
|
- |
| 5.2 (5.2.2, 5.2.1, 5.2.3, shale table-2 ) (Deleterious material (Clay lumps, coal & lignite, material finer than 75 micron IS sieve, Soft fragments,shale)) |
- |
12000 |
|
- |
| 3.2.2
Table 3 ii)
IS 1963(Basicity as CaO/SiO2) |
- |
12000 |
|
- |
| Clause 5.7- Table 3 (i) (TotalAlkali content as Na2O equivalent ) |
- |
12000 |
|
- |
| Clause 5.6(Nature of Aggregate) |
- |
12000 |
|
- |
| Clause 5.6(Dissolved Silica) |
- |
12000 |
|
- |
| Clause 5.6(Reduction in Alkalinity) |
- |
12000 |
|
- |
| Clause 5.1(General) |
- |
12000 |
|
- |
| Clause 5.1(General) |
- |
12000 |
|
- |
| Table 4 Cl. 5.7 (ii)(Total Sulphur as S) |
- |
12000 |
|
- |
| Table 4 Cl. 5.7 (iii)(Total iron as FeO) |
- |
12000 |
|
- |
| Table 5 Cl. 5.7 (i)(Calcium oxide as CaO,) |
- |
12000 |
|
- |
| Table 5 Cl. 5.7 (ii)(Magnesium oxide as MgO) |
- |
12000 |
|
- |
| Table 5 Cl. 5.7 (iii)(Total iron as FeO) |
- |
12000 |
|
- |
| Table 5 Cl. 5.7 (iv)(Basicity as CaO/SiO2) |
- |
12000 |
|
- |
| Table 6 Cl. 5.7 (i)(Calcium oxide as CaO) |
- |
12000 |
|
- |
| Table 6 Cl. 5.7 (ii)(Total sulphur as S) |
- |
12000 |
|
- |
| Table 6 Cl. 5.7 (iii)(Total iron as FeO) |
- |
12000 |
|
- |
| Table 6 Cl. 5.7 (iv)() |
- |
12000 |
|
- |
| Table 6 Cl. 5.7 (iv)() |
- |
12000 |
|
- |
|
22 May, 2029 |
- Included w.e.f. 02.03.2026 |
| 377 |
Shri Krishna Test House
| 8122336
| IS 1660 (2024) |
Wrought and Cast Aluminium Utensils Specification ( Second Revision ) |
- |
30000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl-3.1.1, 3.1.2(Minimum Thickness of Sheet) |
- |
3000 |
|
- |
| Cl-3.1.3, Table-2(Minimum Thickness at the Bottom) |
- |
3000 |
|
- |
| Cl-3.1.3, Table-2(Minimium Thickness of Wall at the Top Edge) |
- |
3000 |
|
- |
| Cl-3.1.3, Table-2(Minimum Cover Thickness) |
- |
3000 |
|
- |
| Cl-4.1(Main body of utensil) |
- |
3000 |
|
- |
| Cl-4.1(Cast cookware) |
- |
3000 |
|
- |
| Cl-4.1(Other aluminum components and parts) |
- |
3000 |
|
- |
| Cl-4.1.1(Lids (material)) |
- |
3000 |
|
- |
| Cl-4.1.1(Minimum thickness of lid) |
- |
3000 |
|
- |
| Cl-4.1.2(Minimum thickness of glass) |
- |
3000 |
|
- |
| Cl-4.1.2(Material of rim) |
- |
3000 |
|
- |
| Cl-4.1.2(Minimum thickness of rim) |
- |
3000 |
|
- |
| Cl-4.2(Material of strips) |
- |
3000 |
|
- |
| Cl-4.2(Stainless steel handles, rivets and fittings) |
- |
3000 |
|
- |
| Cl-4.3(Clips of lunch box) |
- |
3000 |
|
- |
| Cl-4.3(Clips of lunch box) |
- |
3000 |
|
- |
| Cl-4.3(Rivets used in lunch box) |
- |
3000 |
|
- |
| Cl-4.4(Screws, studs/nuts, and locking loop) |
- |
3000 |
|
- |
| Cl-4.5(Rivets for fixing of handles) |
- |
3000 |
|
- |
| Cl-4.5(Material of cap) |
- |
3000 |
|
- |
| Cl-4.6(Strips used for flame guards) |
- |
3000 |
|
- |
| Cl-4.6(stainless steel) |
- |
3000 |
|
- |
| Cl-5(Fabrication) |
- |
3000 |
|
- |
| Cl-6(Shape and Dimensions) |
- |
3000 |
|
- |
| Cl-7.1(Handles, when fitted) |
- |
3000 |
|
- |
| Cl-7.2(Handles) |
- |
3000 |
|
- |
| Cl-7.3 (Cl- 4.1 of IS 13395)(Construction) |
- |
3000 |
|
- |
| Cl-7.3 (Cl- 4.2 of IS 13395)(Materials) |
- |
3000 |
|
- |
| Cl-7.3 (Cl- 4.3 of IS 13395)(Selection and Size) |
- |
3000 |
|
- |
| Cl-7.3 (Cl- 4.4 of IS 13395)(Position of Handle and Knob with Respect to Cookware) |
- |
3000 |
|
- |
| Cl-7.3 (Cl- 4.5 of IS 13395)(Attachment to Cookware) |
- |
3000 |
|
- |
| Cl-7.3 (Cl- 5.2 of IS 13395)(Bending Strength) |
- |
3000 |
|
- |
| Cl-7.3 (Cl- 5.3 of IS 13395)(Torque Strength) |
- |
3000 |
|
- |
| Cl-7.3 (Cl- 5.4 of IS 13395)(Impact Strength) |
- |
3000 |
|
- |
| Cl-7.3 (Cl- 5.5 of IS 13395)(Fatigue Resistance) |
- |
3000 |
|
- |
| Cl-7.3 (Cl- 5.6 of IS 13395)(Leakage) |
- |
3000 |
|
- |
| Cl-7.3 (Cl- 5.7 of IS 13395)(Thermal Insulation) |
- |
3000 |
|
- |
| Wrought and Cast Aluminium Utensils — Specification(Heat Resistance) |
- |
3000 |
|
- |
| Cl-7.3 (Cl- 5.9 of IS 13395)(Washing Resistance (Type Test)) |
- |
3000 |
|
- |
| Cl-7.3 (Cl- 5.10 of IS 13395)(Burning Resistance) |
- |
3000 |
|
- |
| Cl-8(Workmanship and Finish) |
- |
3000 |
|
- |
| Cl-8.3(Utensils, if anodized, fully or partially) |
- |
3000 |
|
- |
| Cl-8.3(Minimum nominal thickness) |
- |
3000 |
|
- |
| Cl-8.3(Thickness of hard anodized) |
- |
3000 |
|
- |
| Cl-8.3(Finish and appearance of hard anodized) |
- |
3000 |
|
- |
| Cl-8.3(Abrasion resistance of hard anodized) |
- |
3000 |
|
- |
| Cl-8.3(Colour of hard anodized) |
- |
3000 |
|
- |
| Cl-8.3(Hardness of hard anodized) |
- |
3000 |
|
- |
| Wrought and Cast Aluminium Utensils — Specification(Lid of the cookware) |
- |
3000 |
|
- |
| Cl-8.5(Non-stick unreinforced PTFE) |
- |
3000 |
|
- |
| Cl-8.6(Ceramic coating) |
- |
3000 |
|
- |
| Cl-8.7(The thickness test, adhesion test) |
- |
3000 |
|
- |
| Cl-8.7(Minimum thickness of coating) |
- |
3000 |
|
- |
| Cl-8.7.1(Dry heat the cookware) |
- |
3000 |
|
- |
| Cl-8.8(Requirements of PTFE) |
- |
3000 |
|
- |
| Cl-8.9(Material for induction plate) |
- |
3000 |
|
- |
| Cl-8.9(Test for Induction compatible base) |
- |
3000 |
|
- |
| Cl-8.10.1(Tests for Lunch Boxes- Performance Test) |
- |
3000 |
|
- |
| Cl-8.10.1(Tests for Lunch Boxes- Performance Test) |
- |
3000 |
|
- |
| Cl-8.10.2(Tests for Lunch Boxes- Ground Nut Oil Test for Leakage) |
- |
3000 |
|
- |
| Cl-8.11.1(Test(s) on Tempered Glass Lid- Fragmentation Test) |
- |
3000 |
|
- |
| Cl-8.11.2(Test(s) on Tempered Glass Lid-Ball Drop Test) |
- |
3000 |
|
- |
| Cl-8.11.3(Test(s) on Tempered Glass Lid- Thermal Shock Test) |
- |
3000 |
|
- |
| Cl-8.11.4(Test(s) on Tempered Glass Lid- Free Fall Test) |
- |
3000 |
|
- |
| Cl-9.1(Normal Capacity) |
- |
3000 |
|
- |
| Cl-9.2(Normal Capacity of internal diameter) |
- |
3000 |
|
- |
| Cl 3.1.4 Table 3 (Amendment No.1)(Thickness of cast cookware- Cast Aluminium- Minimum Base Thickness of Body) |
- |
3000 |
|
- |
|
05 Oct, 2028 |
- - |
| 378 |
Shri Krishna Test House
| 8122336
| IS 14756 (2024) |
Stainless Steel Utensils - Specification (THIRD REVISION) |
All Types |
30000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl 3.1(Material used for manufacturing utensils) |
- |
30000 |
|
- |
| Cl 3.2(Material used for composite bottom) |
- |
30000 |
|
- |
| Cl 3.3(Material used for body of utensil of 3-ply construction) |
- |
30000 |
|
- |
| Cl 3.4(Material used for stainless steel lid) |
- |
30000 |
|
- |
| Cl 3.5(Material used for tempered glass lid) |
- |
30000 |
|
- |
| Cl 3.5(Material used for stainless steel rim) |
- |
30000 |
|
- |
| Cl 4.2 & Table 1(Minimum Sheet Thickness for Body of Utensil) |
- |
30000 |
|
- |
| Cl 4.2 & Table 2(Minimum Sheet Thickness for Lid of Utensil) |
- |
30000 |
|
- |
| Cl 4.2(Thickness of the finished utensil) |
- |
30000 |
|
- |
| Cl 4.3(Classification) |
- |
30000 |
|
- |
| Cl 4.4 (i)(Thickness of Aluminium disc/core) |
- |
30000 |
|
- |
| Cl 4.4 (ii)(Thickness of Protector/cowl) |
- |
30000 |
|
- |
| Cl 4.5(Minimum sheet thickness (3-ply utensil)) |
- |
30000 |
|
- |
| Cl 4.5(Thickness of finished utensil (3-ply utensil)) |
- |
30000 |
|
- |
| Cl 5.1(Manufacturing defect & visual appearance) |
- |
30000 |
|
- |
| CL 5.2(Accessibility for cleaning) |
- |
30000 |
|
- |
| Cl 5.3(Joining of handles to the utensils) |
- |
30000 |
|
- |
| Cl 5.4(Requirement for handles) |
- |
30000 |
|
- |
| Cl 5.5(Welding (Finish)) |
- |
30000 |
|
- |
| Cl 5.6(Finish of 3-ply utensil) |
- |
30000 |
|
- |
| Cl 5.7(Requirement for coating) |
- |
30000 |
|
- |
| Cl 5.8(Coating thickness test) |
- |
30000 |
|
- |
| Cl 5.8(Coating adhesion test) |
- |
30000 |
|
- |
| Cl 5.8.1(Thermal shock test (Coating)) |
- |
30000 |
|
- |
| Cl 6.1(Staining Test (Type Test - Frequency Once in a Year)) |
- |
30000 |
|
- |
| Cl 6.2(Mechanical Shock Test (for Cladded Utensils Only)) |
- |
30000 |
|
- |
| Cl 6.3(Thermal Shock Test (for Cladded Utensils Only)) |
- |
30000 |
|
- |
| Cl 6.4(Dry Heat Test (for Cladded Utensils Only)) |
- |
30000 |
|
- |
| Cl 6.5(Coating Thickness Test (for Copper Deposit)) |
- |
30000 |
|
- |
| Cl 6.6(Thermal shock test (3-ply construction utensil body)) |
- |
30000 |
|
- |
| Cl 6.7(Nominal Capacity Test) |
- |
30000 |
|
- |
| Cl 8(Marking) |
- |
30000 |
|
- |
|
05 Oct, 2028 |
- - |
| 379 |
DELHI TEST HOUSE (50) KUNDLI SONIPAT
| 9127026
| IS 16046 : Part 2 (2018) |
Secondary Cells and Batteries Containing Alkaline or Other Non-Acid Electrolytes ” Safety Requirements for Portable Sealed Secondary Cells and for Batteries Made from Them for Use in Portable Applications Part 2 Lithium Systems ( Second Revision ) |
-- |
100000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4(Parameter Measurement Tolerances) |
- |
500 |
|
Battery- 115000
Cell- 130000 |
| 5(General Safety Considerations) |
- |
250 |
|
Battery- 115000
Cell- 130000 |
| 5.1(General) |
- |
250 |
|
Battery- 115000
Cell- 130000 |
| 5.2(Insulation and Wiring) |
- |
3000 |
|
Battery- 115000
Cell- 130000 |
| 5.3(Venting) |
- |
1000 |
|
Battery- 115000
Cell- 130000 |
| 5.4(Temperature, Voltage and Current Management) |
- |
1000 |
|
Battery- 115000
Cell- 130000 |
| 5.5(Terminal Contacts) |
- |
1000 |
|
Battery- 115000
Cell- 130000 |
| 5.6(Assembly of Cells into batteries) |
- |
5000 |
|
Battery- 115000
Cell- 130000 |
| 5.7(Quality Plan) |
- |
500 |
|
Battery- 115000
Cell- 130000 |
| 5.8(Battery Safety Components) |
- |
500 |
|
Battery- 115000
Cell- 130000 |
| 6(Type Test and Sample Size) |
- |
11000 |
|
Battery- 115000
Cell- 130000 |
| 7(Specific requirements and tests) |
- |
1000 |
|
Battery- 115000
Cell- 130000 |
| 7.1(Charging procedure for test purposes) |
- |
30000 |
|
Battery- 115000
Cell- 130000 |
| 7.2(Intended Use) |
- |
33000 |
|
Battery- 115000
Cell- 130000 |
| 7.3(Reasonably foreseeable misuse) |
- |
63000 |
|
Battery- 115000
Cell- 130000 |
| 8(Information for safety) |
- |
1000 |
|
Battery- 115000
Cell- 130000 |
| 8.1(General) |
- |
1000 |
|
Battery- 115000
Cell- 130000 |
| 8.2(Small Cell and battery safety information) |
- |
1000 |
|
Battery- 115000
Cell- 130000 |
| 9(Marking) |
- |
500 |
|
Battery- 115000
Cell- 130000 |
| 9.1(Cell Marking) |
- |
500 |
|
Battery- 115000
Cell- 130000 |
| 9.2(Battery Marking) |
- |
1000 |
|
Battery- 115000
Cell- 130000 |
| 9.3(Caution for ingestion of small cells and batteries) |
- |
1000 |
|
Battery- 115000
Cell- 130000 |
| 9.4(Other information) |
- |
1000 |
|
Battery- 115000
Cell- 130000 |
| 10(Packaging) |
- |
500 |
|
Battery- 115000
Cell- 130000 |
| clause 7.3.1 of IS 16047: Part 3(Discharge performance at 20 °C (rated capacity)) |
- |
30000 |
|
Battery- 115000Cell- 130000 |
|
23 Jun, 2028 |
- Exclusion : Clause 7.3.1 of IS 16047: Part 3 |
| 380 |
Stellar Test House, Noida
| 8171606
| IS 302 : PART 1 (Commercial Electric Hoods) |
Commercial Electric Hoods |
- |
30000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 6(Classifications) |
- |
500 |
|
- |
| 5(General conditions for tests) |
- |
500 |
|
- |
| 4(General Requirement) |
- |
500 |
|
- |
| 11.8(Temperature rise) |
- |
1000 |
|
- |
| 11.7(Duration corresponding) |
- |
1000 |
|
- |
| 11.6(Combined appliances) |
- |
1000 |
|
- |
| 11.5(Motor-operated appliances) |
- |
1000 |
|
- |
| 11.4(Heating appliances) |
- |
1000 |
|
- |
| 8.1.5(Live parts of built-in appliances) |
- |
1000 |
|
- |
| 18(Endurance) |
- |
1000 |
|
- |
| 17(Overload protection of transformers and associated circuits) |
- |
1000 |
|
- |
| 16(Leakage current and electric strength) |
- |
1000 |
|
- |
| 4(General requirement) |
- |
1000 |
|
- |
| 32(Radiation Toxicity and Similar Hazards) |
- |
1000 |
|
- |
| 31(Resistance to Rusting) |
- |
1000 |
|
- |
| 30.2(Needle Flame Test) |
- |
1000 |
|
- |
| 30.2(Glow Wire Test) |
- |
1000 |
|
- |
| 30.1(Ball pressure test) |
- |
1000 |
|
- |
| 29(clearance, creepage distances and solid insulation) |
- |
1000 |
|
- |
| 28(Screw test and connections) |
- |
1000 |
|
- |
| 27(Provision for earthing) |
- |
1000 |
|
- |
| 26(Terminals for external conductors) |
- |
1000 |
|
- |
| 25(Supply connection and external flexible cords) |
- |
1000 |
|
- |
| 24(Components) |
- |
1000 |
|
- |
| 23(General) |
- |
1000 |
|
- |
| 22(Construction verification related test) |
- |
1000 |
|
- |
| 21(Mechanical Strength Test) |
- |
1000 |
|
- |
| 20(Stability test) |
- |
1000 |
|
- |
| 19(Abnormal Operation) |
- |
1000 |
|
- |
| 18(Endurance Test requirements and tests) |
- |
1000 |
|
- |
| 17(Over Load Protection of Transformers and associated circuits) |
- |
1000 |
|
- |
| 16.3(Electric Strength (after clause 15 and 16.2)) |
- |
1000 |
|
- |
| 16.2(Leakage Current (after Clause 15)) |
- |
1000 |
|
- |
| 16.1(General) |
- |
1000 |
|
- |
| 16.0(General) |
- |
1000 |
|
- |
| 15.3(Humidity Test) |
- |
1000 |
|
- |
| 15.2(Spillage Test) |
- |
1000 |
|
- |
| 15.1(Ingress Protection test other than IPX0 (IP test)) |
- |
1000 |
|
- |
| 15.0(General) |
- |
1000 |
|
- |
| 14(Transient Over Voltages) |
- |
1000 |
|
- |
| 13.3(Electric Strength at operating temperature) |
- |
1000 |
|
- |
| 13.2(Leakage current at operating temperature) |
- |
1000 |
|
- |
| 13.1(General) |
- |
1000 |
|
- |
| 11.3(Heating) |
- |
1000 |
|
- |
| 11.2(General) |
- |
1000 |
|
- |
| 11.1(General) |
- |
1000 |
|
- |
| 10.2(Current input) |
- |
1000 |
|
- |
| 10.1(Power input) |
- |
1000 |
|
- |
| 9(Starting of motor operation test requirements and tests) |
- |
1000 |
|
- |
| 8.1.4(Protection against live parts against protective impedance) |
- |
1000 |
|
- |
| 8.1.3(Protection against live parts in visible glowing heating elements) |
- |
1000 |
|
- |
| 8.1.2(Protection against live parts in openings) |
- |
1000 |
|
- |
| 8.1.1(Protection against live parts in all positions) |
- |
1000 |
|
- |
| 7(Marking and instructions) |
- |
500 |
|
- |
|
26 Sep, 2028 |
- "1 19.11.4.7 (Harmonics) EMI/EMC Test Test facilities not available
2 19.11.4.6 (Class 3 Voltage dips and interruptions) EMI/EMC Test Test facilities not available
3 19.11.4.5 (Immunity to conducted discharges) EMI/EMC Test Test facilities not available
4 19.11.4.4 (Surge immunity test) EMI/EMC Test Test facilities not available
5 19.11.4.3 (Fast transient bursts) EMI/EMC Test Test facilities not available
6 19.11.4.2 (Radiated fields) EMI/EMC Test Test facilities not available
7 19.11.4.1 (Electrostatic discharges) EMI/EMC Test Test facilities not available
" |
| 381 |
Stellar Test House, Noida
| 8171606
| IS 302 : PART 1 (Single Walled Baking Ovens) |
Single Walled Baking Ovens |
- |
30000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 32(RADIATION HAZARDS) |
- |
1000 |
|
- |
| 31(RESISTANCE TO RUSTING) |
- |
1000 |
|
- |
| 30(RESISTANCE TO HEAT, FIRE AND TACKING) |
- |
1000 |
|
- |
| 29(CREEPAGE DISTANCES, CLEARANCES AND DISTANCES THROUGH INSULATION) |
- |
1000 |
|
- |
| 28(SCREWS AND CONNECTIONS) |
- |
1000 |
|
- |
| 27(PROVISION FOR EARTHING) |
- |
1000 |
|
- |
| 26(TERMINALS FOR EXTERNAL CONDUCTORS) |
- |
1000 |
|
- |
| 25(SUPPLY CONNECTION AND EXTERNAL FLEXIBLE CABLES AND CORDS) |
- |
1000 |
|
- |
| 24(COMPONENTS) |
- |
1000 |
|
- |
| 23(INTERNAL WIRING) |
- |
1000 |
|
- |
| 22(CONSTRUCTION) |
- |
1000 |
|
- |
| 21(MECHANICAL STRENGTH) |
- |
1000 |
|
- |
| 20(STABILITY AND MECHANICAL HAZARDS) |
- |
1000 |
|
- |
| 19(ABNORMAL OPERATION) |
- |
1000 |
|
- |
| 18(ENDURANCE) |
- |
1000 |
|
- |
| 17(OVERLOAD PROTECTION) |
- |
1000 |
|
- |
| 16("INSULATION RESISTANCE AND ELECTRIC SHOCK STRENGTH
( AFTER HUMIDITY TREATMENT )") |
- |
1000 |
|
- |
| 15(MOISTURE RESESTANCE) |
- |
1000 |
|
- |
| 14(RADIO AND TELEVISION INTERFERENCE SUPPRESSION) |
- |
1000 |
|
- |
| 13("ELECTRICAL INSULATION AND LEAKAGE CURRENT
AT OPERATING TEMPERATURE") |
- |
1000 |
|
- |
| 12("OPERATLON UNDER OVERLOAD CONDITIONS OF APPLIANCES
WITH HEATING ELEMENTS") |
- |
1000 |
|
- |
| 11(TEMPERATURE RISE) |
- |
1000 |
|
- |
| 10(INPUT AND CURRENT) |
- |
1000 |
|
- |
| 9(STARTING OF MOTOR-OPERATING APPLIANCES) |
- |
1000 |
|
- |
| 8(PROTECTION AGAINST ELECTRIC SHOCK) |
- |
1000 |
|
- |
| 7(MARKING) |
- |
500 |
|
- |
| 6(CLASSIFICATION) |
- |
500 |
|
- |
| 5(RATING) |
- |
500 |
|
- |
| 4(GENERAL NOTES ON TESTS) |
- |
500 |
|
- |
| 3(GENERAL REQUIREMENT) |
- |
500 |
|
- |
| 101.3(Routine Tests) |
- |
1000 |
|
- |
| 101.2(Acceptance Tests) |
- |
1000 |
|
- |
| 101.1(Type Tests) |
- |
1000 |
|
- |
|
26 Sep, 2028 |
- 1.
Cl-19.11.4.7 (Harmonics) EMI/EMC Test Test facilities not available
2.
Cl-19.11.4.6 (Voltage dips and interruptions) EMI/EMC Test Test facilities not available
3.
Cl-19.11.4.5 (Immunity to conducted discharge) EMI/EMC Test Test facilities not available
4.
Cl-19.11.4.4 (Surge Immunity test) EMI/EMC Test Test facilities not available
5.
Cl-19.11.4.3 (Fast transient bursts) EMI/EMC Test Test facilities not available
6.
Cl-19.11.4.2 (Radiated Fields) EMI/EMC Test Test facilities not available
7.
Cl-19.11.4.1 (Electrostatic discharge) EMI/EMC Test Test facilities not available" |
| 382 |
Stellar Test House, Noida
| 8171606
| IS 302 : PART 1 (Electrolysers) |
Electrolysers |
- |
30000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 6(Classifications) |
- |
500 |
|
- |
| 5(General conditions for tests) |
- |
500 |
|
- |
| 4(General Requirement) |
- |
500 |
|
- |
| 11.8(Temperature rise) |
- |
1000 |
|
- |
| 11.7(Duration corresponding) |
- |
1000 |
|
- |
| 11.6(Combined appliances) |
- |
1000 |
|
- |
| 11.5(Motor-operated appliances) |
- |
1000 |
|
- |
| 11.4(Heating appliances) |
- |
1000 |
|
- |
| 8.1.5(Live parts of built-in appliances) |
- |
1000 |
|
- |
| 18(Endurance) |
- |
1000 |
|
- |
| 17(Overload protection of transformers and associated circuits) |
- |
1000 |
|
- |
| 16(Leakage current and electric strength) |
- |
1000 |
|
- |
| 4(General requirement) |
- |
1000 |
|
- |
| 32(Radiation Toxicity and Similar Hazards) |
- |
1000 |
|
- |
| 31(Resistance to Rusting) |
- |
1000 |
|
- |
| 30.2(Needle Flame Test) |
- |
1000 |
|
- |
| 30.2(Glow Wire Test) |
- |
1000 |
|
- |
| 30.1(Ball pressure test) |
- |
1000 |
|
- |
| 29(clearance, creepage distances and solid insulation) |
- |
1000 |
|
- |
| 28(Screw test and connections) |
- |
1000 |
|
- |
| 27(Provision for earthing) |
- |
1000 |
|
- |
| 26(Terminals for external conductors) |
- |
1000 |
|
- |
| 25(Supply connection and external flexible cords) |
- |
1000 |
|
- |
| 24(Components) |
- |
1000 |
|
- |
| 23(General) |
- |
1000 |
|
- |
| 22(Construction verification related test) |
- |
1000 |
|
- |
| 21(Mechanical Strength Test) |
- |
1000 |
|
- |
| 20(Stability test) |
- |
1000 |
|
- |
| 19(Abnormal Operation) |
- |
1000 |
|
- |
| 18(Endurance Test requirements and tests) |
- |
1000 |
|
- |
| 17(Over Load Protection of Transformers and associated circuits) |
- |
1000 |
|
- |
| 16.3(Electric Strength (after clause 15 and 16.2)) |
- |
1000 |
|
- |
| 16.2(Leakage Current (after Clause 15)) |
- |
1000 |
|
- |
| 16.1(General) |
- |
1000 |
|
- |
| 15.3(Humidity Test) |
- |
1000 |
|
- |
| 15.2(Spillage Test) |
- |
1000 |
|
- |
| 15.1(Ingress Protection test other than IPX0 (IP test)) |
- |
1000 |
|
- |
| 15.0(General) |
- |
1000 |
|
- |
| 14(Transient Over Voltages) |
- |
1000 |
|
- |
| 13.3(Electric Strength at operating temperature) |
- |
1000 |
|
- |
| 13.2(Leakage current at operating temperature) |
- |
1000 |
|
- |
| 13.1(General) |
- |
1000 |
|
- |
| 11.3(Heating) |
- |
1000 |
|
- |
| 11.2(General) |
- |
1000 |
|
- |
| 11.1(General) |
- |
1000 |
|
- |
| 10.2(Current input) |
- |
1000 |
|
- |
| 10.1(Power input) |
- |
1000 |
|
- |
| 9(Starting of motor operation test requirements and tests) |
- |
1000 |
|
- |
| 8.1.4(Protection against live parts against protective impedance) |
- |
1000 |
|
- |
| 8.1.3(Protection against live parts in visible glowing heating elements) |
- |
1000 |
|
- |
| 8.1.2(Protection against live parts in openings) |
- |
1000 |
|
- |
| 8.1.1(Protection against live parts in all positions) |
- |
1000 |
|
- |
| 7(Marking and instructions) |
- |
500 |
|
- |
|
26 Sep, 2028 |
- 1.
19.11.4.7 (Harmonics) EMI/EMC Test Test facilities not available
2.
19.11.4.6 (Class 3 Voltage dips and interruptions) EMI/EMC Test Test facilities not available
3.
19.11.4.5 (Immunity to conducted discharges) EMI/EMC Test Test facilities not available
4.
19.11.4.4 (Surge immunity test) EMI/EMC Test Test facilities not available
5.
19.11.4.3 (Fast transient bursts) EMI/EMC Test Test facilities not available
6.
19.11.4.2 (Radiated fields) EMI/EMC Test Test facilities not available
7.
19.11.4.1 (Electrostatic discharges) EMI/EMC Test Test facilities not available" |
| 383 |
Stellar Test House, Noida
| 8171606
| IS 302 : PART 1 (Warming Plates and Similar Appliances) |
Warming Plates and Similar Appliances |
- |
30000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 32(Radiation hazards) |
- |
1000 |
|
- |
| 31(Resistance to Rusting) |
- |
1000 |
|
- |
| 30(Resistance to Heat & Fire) |
- |
1000 |
|
- |
| 29(Clearances, Creepage Distances & Solid Insulation) |
- |
1000 |
|
- |
| 28(Screws & Connections) |
- |
1000 |
|
- |
| 27(Provision For Earthing) |
- |
1000 |
|
- |
| 26(Terminals For External Conductors) |
- |
1000 |
|
- |
| 25(Supply Connection & External Flexible Cords) |
- |
1000 |
|
- |
| 24(Components) |
- |
1000 |
|
- |
| 23(Internal Wiring) |
- |
1000 |
|
- |
| 22(Construction) |
- |
1000 |
|
- |
| 21(Mechanical strength) |
- |
1000 |
|
- |
| 20(Stability & Mechanical Hazards) |
- |
1000 |
|
- |
| 19(Abnormal Operation) |
- |
1000 |
|
- |
| 18(Endurance) |
- |
1000 |
|
- |
| 17(Overload Protection/ Overload Protection of Transformers & Associated Circuits) |
- |
1000 |
|
- |
| 16(Insulation Resistance and Electric Strength/ Leakage Current and Electric Strength) |
- |
1000 |
|
- |
| 15(Moisture Resistance) |
- |
1000 |
|
- |
| 14("""Radio and Television Interference Suppression / Transient Over Voltage
""") |
- |
1000 |
|
- |
| 13(Leakage Current and Electric Strength at Operating Temperature) |
- |
1000 |
|
- |
| 12(Operation Under Overload Conditions of Appliances with heating Element) |
- |
1000 |
|
- |
| 11(Temperature Rise/ Heating) |
- |
1000 |
|
- |
| 10("""Power Input
& Current""") |
- |
1000 |
|
- |
| 9(Starting Of Motor Operated Appliances) |
- |
1000 |
|
- |
| 8(Protection against Access to Live Parts) |
- |
1000 |
|
- |
| 7(Marking) |
- |
500 |
|
- |
| 6(Classification) |
- |
500 |
|
- |
| 5(Rating) |
- |
500 |
|
- |
|
26 Sep, 2028 |
- included w.e.f 01.04.2026 |
| 384 |
Stellar Test House, Noida
| 8171606
| IS 302 : PART 1 (Water-Bed Heaters) |
Water-Bed Heaters |
- |
30000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 6(Classifications) |
- |
500 |
|
- |
| 5(General conditions for tests) |
- |
500 |
|
- |
| 4(General Requirement) |
- |
500 |
|
- |
| 11.8(Temperature rise) |
- |
1000 |
|
- |
| 11.7(Duration corresponding) |
- |
1000 |
|
- |
| 11.6(Combined appliances) |
- |
1000 |
|
- |
| 11.5(Motor-operated appliances) |
- |
1000 |
|
- |
| 11.4(Heating appliances) |
- |
1000 |
|
- |
| 8.1.5(Live parts of built-in appliances) |
- |
1000 |
|
- |
| 18(Endurance) |
- |
1000 |
|
- |
| 17(Overload protection of transformers and associated circuits) |
- |
1000 |
|
- |
| 16(Leakage current and electric strength) |
- |
1000 |
|
- |
| 4(General requirement) |
- |
500 |
|
- |
| 32(Radiation Toxicity and Similar Hazards) |
- |
1000 |
|
- |
| 31(Resistance to Rusting) |
- |
1000 |
|
- |
| 30.2(Needle Flame Test) |
- |
1000 |
|
- |
| 30.2(Glow Wire Test) |
- |
1000 |
|
- |
| 30.1(Ball pressure test) |
- |
1000 |
|
- |
| 29(clearance, creepage distances and solid insulation) |
- |
1000 |
|
- |
| 28(Screw test and connections) |
- |
1000 |
|
- |
| 27(Provision for earthing) |
- |
1000 |
|
- |
| 26(Terminals for external conductors) |
- |
1000 |
|
- |
| 25(Supply connection and external flexible cords) |
- |
1000 |
|
- |
| 24(Components) |
- |
1000 |
|
- |
| 23(General) |
- |
1000 |
|
- |
| 22(Construction verification related test) |
- |
1000 |
|
- |
| 21(Mechanical Strength Test) |
- |
1000 |
|
- |
| 20(Stability test) |
- |
1000 |
|
- |
| 19(Abnormal Operation) |
- |
1000 |
|
- |
| 18(Endurance Test requirements and tests) |
- |
1000 |
|
- |
| 17(Over Load Protection of Transformers and associated circuits) |
- |
1000 |
|
- |
| 16.3(Electric Strength (after clause 15 and 16.2)) |
- |
1000 |
|
- |
| 16.2(Leakage Current (after Clause 15)) |
- |
1000 |
|
- |
| 16.1(General) |
- |
1000 |
|
- |
| 16.0(General) |
- |
1000 |
|
- |
| 15.3(Humidity Test) |
- |
1000 |
|
- |
| 15.2(Spillage Test) |
- |
1000 |
|
- |
| 15.1(Ingress Protection test other than IPX0 (IP test)) |
- |
1000 |
|
- |
| 15.0(General) |
- |
1000 |
|
- |
| 14(Transient Over Voltages) |
- |
1000 |
|
- |
| 13.3(Electric Strength at operating temperature) |
- |
1000 |
|
- |
| 13.2(Leakage current at operating temperature) |
- |
1000 |
|
- |
| 13.1(General) |
- |
1000 |
|
- |
| 11.3(Heating) |
- |
1000 |
|
- |
| 11.2(General) |
- |
1000 |
|
- |
| 11.1(General) |
- |
1000 |
|
- |
| 10.2(Current input) |
- |
1000 |
|
- |
| 10.1(Power input) |
- |
1000 |
|
- |
| 9(Starting of motor operation test requirements and tests) |
- |
1000 |
|
- |
| 8.1.4(Protection against live parts against protective impedance) |
- |
1000 |
|
- |
| 8.1.3(Protection against live parts in visible glowing heating elements) |
- |
1000 |
|
- |
| 8.1.2(Protection against live parts in openings) |
- |
1000 |
|
- |
| 8.1.1(Protection against live parts in all positions) |
- |
1000 |
|
- |
| 7(Marking and instructions) |
- |
500 |
|
- |
|
26 Sep, 2028 |
- "1 19.11.4.7 (Harmonics) EMI/EMC Test Test facilities not available
2 19.11.4.6 (Class 3 Voltage dips and interruptions) EMI/EMC Test Test facilities not available
3 19.11.4.5 (Immunity to conducted discharges) EMI/EMC Test Test facilities not available
4 19.11.4.4 (Surge immunity test) EMI/EMC Test Test facilities not available
5 19.11.4.3 (Fast transient bursts) EMI/EMC Test Test facilities not available
6 19.11.4.2 (Radiated fields) EMI/EMC Test Test facilities not available
7 19.11.4.1 (Electrostatic discharges) EMI/EMC Test Test facilities not available" |
| 385 |
ACE TEST LAB PRIVATE LIMITED (8166826), DELHI
| 8166826
| IS 302 : Part 2 : Sec 25 (2014) |
Safety of household and similar electrical appliances: Part 2 Particular requirements: Section 25 Microwave ovens |
- |
45000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 6.0(Classification) |
- |
1730 |
|
- |
| 7(Marking and instructions) |
- |
1730 |
|
- |
| 8(Protection against live parts) |
- |
1730 |
|
- |
| 9(STARTING OF MOTOR-OPERATED APPLIANCES) |
- |
1730 |
|
- |
| 10(POWER INPUT AND CURRENT) |
- |
1730 |
|
- |
| 11(HEATING) |
- |
1730 |
|
- |
| 13(LEAKAGE CURRENT AND ELECTRIC STRENGTH AT OPERATING TEMPERATURE) |
- |
1730 |
|
- |
| 14(IMPULSE VOLTAGE TEST) |
- |
1730 |
|
- |
| 15(HUMIDITY TREATMENT TEST) |
- |
1730 |
|
- |
| 16(LEAKAGE CURRENT AND ELECTRIC STRENGTH) |
- |
1730 |
|
- |
| 17(OVERLOAD PROTECTION OF TRANSFORMERS AND ASSOCIATED CIRCUITS) |
- |
1730 |
|
- |
| 18(ENDURANCE) |
- |
1730 |
|
- |
| 19(ABNORMAL OPERATION) |
- |
1730 |
|
- |
| 20(STABILITY AND MECHANICAL HAZARDS) |
- |
1730 |
|
- |
| 21(MECHANICAL STRENGTH) |
- |
1730 |
|
- |
| 22(CONSTRUCTION) |
- |
1730 |
|
- |
| 23(INTERNAL WIRING) |
- |
1730 |
|
- |
| 24(COMPONENTS) |
- |
1730 |
|
- |
| 25(SUPPLY CONNECTION AND EXTERNAL FLEXIBLE CORDS) |
- |
1730 |
|
- |
| 26(TERMINALS FOR EXTERNAL CONDUCTORS) |
- |
1730 |
|
- |
| 27(PROVISION FOR EARTHING) |
- |
1730 |
|
- |
| 28(SCREWS AND CONNECTIONS) |
- |
1730 |
|
- |
| 29(CLEARANCES, CREEPAGE DISTANCES AND SOLID INSULATION) |
- |
1730 |
|
- |
| 30(RESISTANCE TO HEAT AND FIRE) |
- |
1730 |
|
- |
| 32(RADIATION, TOXICITY AND SIMILAR HAZARDS) |
- |
1730 |
|
- |
| 31(RESISTANCE TO RUSTING) |
- |
1750 |
|
- |
|
- |
- Included w.e.f 24.03.2026
Exclusion:Cl 19.11.4.1-19.11.4.7(EMI/EMC), 22.46 (Software), 22.32 (Oxygen bomb for rubber material) |
| 386 |
Nextron International Lab Private Limited
| 9140226
| IS 16047 : Part 3 (2018) |
Secondary Cells and Batteries Containing Alkaline or Other Non-Acid Electrolytes ” Secondary Lithium Cells and Batteries for Portable Applications Part 3 Prismatic and Cylindrical Lithium Secondary Cells, and Batteries Made From Them ( First Revision ) |
- |
100000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 5(Cell Designation and Marking) |
- |
5000 |
|
- |
| 7.1, 7.2(Charging Procedure for Test Purpose) |
- |
5000 |
|
- |
| 7.3.1(Discharge Performance at 20°C (Rated Capacity)) |
- |
25000 |
|
- |
| 7.3.2("Discharge Performance at
-20°C ") |
- |
5000 |
|
- |
| 7.3.3(High Rate Discharge Performance at 20°C) |
- |
5000 |
|
- |
| 7.4(Charge (capacity) Retention and Recovery) |
- |
15000 |
|
- |
| 7.5(Charge (Capacity) Recovery After Long Term Storage) |
- |
15000 |
|
- |
| 7.6.2(Endurance In Cycles at a Rate of 0.2It A) |
- |
15000 |
|
- |
| 7.6.3("Endurance in Cycles at a Rate of 0.5It A
(Accelerated Test Procedure)
") |
- |
15000 |
|
- |
| 7.7(Battery Internal Resistance) |
- |
5000 |
|
- |
| 5(Cell Designation and Marking) |
- |
5000 |
|
- |
| 7.1, 7.2(Charging Procedure for Test Purpose) |
- |
5000 |
|
- |
| 7.3.1(Discharge Performance at 20°C (Rated Capacity)) |
- |
25000 |
|
- |
| 7.3.2("Discharge Performance at
-20°C ") |
- |
5000 |
|
- |
| 7.3.3(High Rate Discharge Performance at 20°C) |
- |
5000 |
|
- |
| 7.4(Charge (capacity) Retention and Recovery) |
- |
15000 |
|
- |
| 7.5(Charge (Capacity) Recovery After Long Term Storage) |
- |
15000 |
|
- |
| 7.6.2(Endurance In Cycles at a Rate of 0.2It A) |
- |
15000 |
|
- |
| 7.6.3("Endurance in Cycles at a Rate of 0.5It A
(Accelerated Test Procedure)
") |
- |
15000 |
|
- |
| 7.7(Battery Internal Resistance) |
- |
5000 |
|
- |
|
06 Jun, 2027 |
- 1 7.8 (Electrostatic Discharge (ESD)) ESD NOT REQUIRED. |
| 387 |
CIPET: CENTRE FOR SKILLING AND TECHNICAL SUPPORT (CSTS) - (CIPET), AURANGABAD
| 7123534
| IS 16058 (2024) |
Dunnage pallets made from recycled packaging wastes for warehousing application - Specification (First Revision) |
- |
26600 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl-8.1.1(Nails) |
- |
500 |
|
- |
| Cl-8.1.2(Threaded Nail) |
- |
500 |
|
- |
| Cl-8.1.3(Ring Nail) |
- |
500 |
|
- |
| Cl-8.1.4(Interrupted Thread Nail) |
- |
500 |
|
- |
| Cl-8.1.6(Screw) |
- |
500 |
|
- |
| Cl-8.2(Requirements for Fasteners) |
- |
500 |
|
- |
| Cl-11.1(Dimensions of Pallet Type “A-1”) |
- |
2000 |
|
4 parameters |
| Cl-11.1.1(Dimensions of Top Plank of Pallet Type “A-1”) |
- |
2500 |
|
5 parameters |
| Cl-11.2(Dimensions of Pallet Type “A-2”) |
- |
0 |
|
- |
| Cl-11.2.1(Dimensions of Top Plank of Pallet Type “A-2”) |
- |
0 |
|
- |
| Cl-11.3(Dimensions of Pallet Type “B”) |
- |
0 |
|
- |
| Cl-11.3.1(Dimensions of Top Plank of Pallet Type “B”) |
- |
0 |
|
- |
| Cl-11.3.2(Dimensions of Bottom Support Plank of Pallet Type “B”) |
- |
2500 |
|
5 parameters |
| Cl-12(Workmanship) |
- |
500 |
|
- |
| Cl-13(Finish) |
- |
500 |
|
- |
| Cl-15.1(Stacking Test Using Static Load) |
- |
1800 |
|
1100+700 |
| Cl-15.2(Vertical Impact Drop Test) |
- |
1100 |
|
- |
| Cl-15.3(Corner Drop Test) |
- |
1100 |
|
- |
| Cl-15.4(Hammer Test) |
- |
1100 |
|
- |
| Cl-15.5(Load Bearing Test) |
- |
1100 |
|
- |
| Cl-17.1 (i)(Density (kg/m³)) |
- |
700 |
|
- |
| Cl-17.2 (ii)(Tensile stress at proportional limits (kg/cm2)) |
- |
1300 |
|
- |
| Cl-17.2 (iii)(Tensile stress at maximum load (kg/cm2)) |
- |
1300 |
|
- |
| Cl-17.2 (iv)(Modulus of elasticity in tension parallel to grain (kg/cm²)) |
- |
1300 |
|
- |
| Cl-17.2 (v)(F alling impact strength, minimum height of fall (cm)) |
- |
1100 |
|
- |
| Cl-17.2 (vi)(Compression parallel to surface test (Min), (kg/cm²)) |
- |
1100 |
|
- |
| Cl-17.3 (i)(Moisture (percent, Max)) |
- |
1100 |
|
- |
| Cl-17.3 (ii)(Water absorption 2 h (percent, Max)) |
- |
1700 |
|
700+1000 |
| Cl-17.3 (iii)(Water absorption 24 h (percent, Max)) |
- |
1700 |
|
700+1000 |
| Cl-17.3 (iv)(Acidity and alkalinity resistance test) |
- |
1100 |
|
- |
| Cl-20(Marking) |
- |
500 |
|
- |
| 14(Conditioning) |
- |
0 |
|
- |
| Cl-8.1.5(Collated Nail) |
- |
500 |
|
- |
|
31 Dec, 2026 |
- Included w.e.f. 26.02.2026
Exclusion: Cl-16 (Routine Tests) |
| 388 |
Stellar Test House, Noida
| 8171606
| IS 302 : PART 1 (Massage Appliances) |
Massage Appliances |
- |
30000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| (CI. 6 IS 302-2-32 : 1994(Classification) |
- |
500 |
|
- |
| Cl. 7 302-2-32 : 1994(Marking) |
- |
500 |
|
- |
| Cl. 8 302-2-32 : 1994(Starting of motor operated appliances) |
- |
1000 |
|
- |
| Cl. 9 302-2-32 : 1994(Protection Against Electric Shock) |
- |
1000 |
|
- |
| Cl. 10 302-2-32 : 1994(Power Input and Current) |
- |
1000 |
|
- |
| Cl. 11 302-2-32 : 1994(Temperature Rise) |
- |
1000 |
|
- |
| Cl. 13 302-2-32 : 1994(Leakage Current & Electric Strength at Operating Temperature) |
- |
1000 |
|
- |
| Cl. 14 302-2-32 : 1994(Radio and television interference suppression / Transient over voltages) |
- |
1000 |
|
- |
| Cl. 15 302-2-32: 1994(Moisture Resistance Test) |
- |
1000 |
|
- |
| Cl. 16 302-2-32 : 1994(Leakage Current & Electric Strength at Operating Temperature (After Humidity Treatment)) |
- |
1000 |
|
- |
| Cl. 17 302-2-32 : 1994(Overload Protection of Transformers and Associated Circuit) |
- |
1000 |
|
- |
| Cl. 18 302-2-32 : 1994(Endurance) |
- |
1000 |
|
- |
| Cl. 19 302-2-32 : 1994(Abnormal Operation) |
- |
1000 |
|
- |
| Cl. 20 302-2-32 : 1994(Stability & Mechanical Hazards) |
- |
1000 |
|
- |
| Cl. 21 302-2-32 : 1994(Mechanical strength) |
- |
1000 |
|
- |
| Cl. 22 302-2-32 : 1994(Construction) |
- |
1000 |
|
- |
| Cl. 23 302-2-32 : 1994(Internal Wiring) |
- |
1000 |
|
- |
| Cl. 24 302-2-32 : 1994(Components) |
- |
1000 |
|
- |
| Cl. 25 302-2-32 : 1994(Supply Connection & External Flexible Cords) |
- |
1000 |
|
- |
| Cl. 26 302-2-32 : 1994(Terminals for External conductors) |
- |
1000 |
|
- |
| Cl. 27 302-2-32 : 1994(Provision for Earthing) |
- |
1000 |
|
- |
| Cl. 28 302-2-32 : 1994(Screws & Connections) |
- |
1000 |
|
- |
| Cl. 29 302-2-32 : 1994(Clearances, Creepage Distances & Solid insulation) |
- |
1000 |
|
- |
| Cl. 30 302-2-32 : 1994(Resistance to Heat Fire & Tracking) |
- |
1000 |
|
- |
| Cl. 31 302-2-32 : 1994(Resistance to Rusting) |
- |
1000 |
|
- |
| Cl. 32 302-2-32 : 1994(Radiation Hazards) |
- |
1000 |
|
- |
|
26 Sep, 2028 |
- "1 19.11.4.7 (Harmonics) EMI/EMC Test Test facilities not available
2 19.11.4.6 (Class 3 Voltage dips and interruptions) EMI/EMC Test Test facilities not available
3 19.11.4.5 (Immunity to conducted discharges) EMI/EMC Test Test facilities not available
4 19.11.4.4 (Surge immunity test) EMI/EMC Test Test facilities not available
5 19.11.4.3 (Fast transient bursts) EMI/EMC Test Test facilities not available
6 19.11.4.2 EMI/EMC Test Test facilities not available
7 19.11.4.2 EMI/EMC Test Test facilities not available
8 19.11.4.2 EMI/EMC Test Test facilities not available
9 19.11.4.2 EMI/EMC Test Test facilities not available
10 19.11.4.2 EMI/EMC Test Test facilities not available
11 19.11.4.2 EMI/EMC Test Test facilities not available
12 19.11.4.2 EMI/EMC Test Test facilities not available
13 19.11.4.2 (Radiated fields) EMI/EMC Test Test facilities not available
14 19.11.4.1 (Electrostatic discharges) EMI/EMC Test Test facilities not available"
15 32 (Radiation Toxicity and Similar Hazards)
16 24 (Components) |
| 389 |
Stellar Test House, Noida
| 8171606
| IS 302 : PART 1 (Commercial Electric Dishwashing Machines) |
Commercial Electric Dishwashing Machines |
- |
30000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 6(Classifications) |
- |
500 |
|
- |
| 5(General conditions for tests) |
- |
500 |
|
- |
| 4(General Requirement) |
- |
500 |
|
- |
| 11.8(Temperature rise) |
- |
1000 |
|
- |
| 11.7(Duration corresponding) |
- |
1000 |
|
- |
| 11.6(Combined appliances) |
- |
1000 |
|
- |
| 11.5(Motor-operated appliances) |
- |
1000 |
|
- |
| 11.4(Heating appliances) |
- |
1000 |
|
- |
| 8.1.5(Live parts of built-in appliances) |
- |
1000 |
|
- |
| 18(Endurance) |
- |
1000 |
|
- |
| 17(Overload protection of transformers and associated circuits) |
- |
1000 |
|
- |
| 16(Leakage current and electric strength) |
- |
1000 |
|
- |
| 4(General requirement) |
- |
500 |
|
- |
| 32(Radiation Toxicity and Similar Hazards) |
- |
1000 |
|
- |
| 31(Resistance to Rusting) |
- |
1000 |
|
- |
| 30.2(Needle Flame Test) |
- |
1000 |
|
- |
| 30.2(Glow Wire Test) |
- |
1000 |
|
- |
| 30.1(Ball pressure test) |
- |
1000 |
|
- |
| 29(clearance, creepage distances and solid insulation) |
- |
1000 |
|
- |
| 28(Screw test and connections) |
- |
1000 |
|
- |
| 27(Provision for earthing) |
- |
1000 |
|
- |
| 26(Terminals for external conductors) |
- |
1000 |
|
- |
| 25(Supply connection and external flexible cords) |
- |
1000 |
|
- |
| 24(Components) |
- |
1000 |
|
- |
| 23(General) |
- |
1000 |
|
- |
| 22(Construction verification related test) |
- |
1000 |
|
- |
| 21(Mechanical Strength Test) |
- |
1000 |
|
- |
| 20(Stability test) |
- |
1000 |
|
- |
| 19(Abnormal Operation) |
- |
1000 |
|
- |
| 18(Endurance Test requirements and tests) |
- |
1000 |
|
- |
| 17(Over Load Protection of Transformers and associated circuits) |
- |
1000 |
|
- |
| 16.3(Electric Strength (after clause 15 and 16.2)) |
- |
1000 |
|
- |
| 16.2(Leakage Current (after Clause 15)) |
- |
1000 |
|
- |
| 16.1(General) |
- |
1000 |
|
- |
| 16.0(General) |
- |
1000 |
|
- |
| 15.3(Humidity Test) |
- |
1000 |
|
- |
| 15.2(Spillage Test) |
- |
1000 |
|
- |
| 15.1(Ingress Protection test other than IPX0 (IP test)) |
- |
1000 |
|
- |
| 15.0(General) |
- |
1000 |
|
- |
| 14(Transient Over Voltages) |
- |
1000 |
|
- |
| 13.3(Electric Strength at operating temperature) |
- |
1000 |
|
- |
| 13.2(Leakage current at operating temperature) |
- |
1000 |
|
- |
| 13.1(General) |
- |
1000 |
|
- |
| 11.3(Heating) |
- |
1000 |
|
- |
| 11.2(General) |
- |
1000 |
|
- |
| 11.1(General) |
- |
1000 |
|
- |
| 10.2(Current input) |
- |
1000 |
|
- |
| 10.1(Power input) |
- |
1000 |
|
- |
| 9(Starting of motor operation test requirements and tests) |
- |
1000 |
|
- |
| 8.1.4(Protection against live parts against protective impedance) |
- |
1000 |
|
- |
| 8.1.3(Protection against live parts in visible glowing heating elements) |
- |
1000 |
|
- |
| 8.1.2(Protection against live parts in openings) |
- |
1000 |
|
- |
| 8.1.1(Protection against live parts in all positions) |
- |
1000 |
|
- |
| 7(Marking and instructions) |
- |
500 |
|
- |
|
26 Sep, 2028 |
- "1 19.11.4.7 (Harmonics) EMI/EMC Test Test facilities not available
2 19.11.4.6 (Class 3 Voltage dips and interruptions) EMI/EMC Test Test facilities not available
3 19.11.4.5 (Immunity to conducted discharges) EMI/EMC Test Test facilities not available
4 19.11.4.4 (Surge immunity test) EMI/EMC Test Test facilities not available
5 19.11.4.3 (Fast transient bursts) EMI/EMC Test Test facilities not available
6 19.11.4.2 (Radiated fields) EMI/EMC Test Test facilities not available
7 19.11.4.1 (Electrostatic discharges) EMI/EMC Test Test facilities not available"
8 32 (Radiation Toxicity and Similar Hazards)
9 24 (Components) |
| 390 |
Stellar Test House, Noida
| 8171606
| IS 302 : PART 1 (Dishwashers) |
Dishwashers |
- |
30000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 6(Classifications) |
- |
500 |
|
- |
| 5(General conditions for tests) |
- |
500 |
|
- |
| 4(General Requirement) |
- |
500 |
|
- |
| 11.8(Temperature rise) |
- |
1000 |
|
- |
| 11.7(Duration corresponding) |
- |
1000 |
|
- |
| 11.6(Combined appliances) |
- |
1000 |
|
- |
| 11.5(Motor-operated appliances) |
- |
1000 |
|
- |
| 11.4(Heating appliances) |
- |
1000 |
|
- |
| 8.1.5(Live parts of built-in appliances) |
- |
1000 |
|
- |
| 18(Endurance) |
- |
1000 |
|
- |
| 17(Overload protection of transformers and associated circuits) |
- |
1000 |
|
- |
| 16(Leakage current and electric strength) |
- |
1000 |
|
- |
| 4(General requirement) |
- |
500 |
|
- |
| 32(Radiation Toxicity and Similar Hazards) |
- |
1000 |
|
- |
| 31(Resistance to Rusting) |
- |
1000 |
|
- |
| 30.2(Needle Flame Test) |
- |
1000 |
|
- |
| 30.2(Glow Wire Test) |
- |
1000 |
|
- |
| 30.1(Ball pressure test) |
- |
1000 |
|
- |
| 29(clearance, creepage distances and solid insulation) |
- |
1000 |
|
- |
| 28(Screw test and connections) |
- |
1000 |
|
- |
| 27(Provision for earthing) |
- |
1000 |
|
- |
| 26(Terminals for external conductors) |
- |
1000 |
|
- |
| 25(Supply connection and external flexible cords) |
- |
1000 |
|
- |
| 24(Components) |
- |
1000 |
|
- |
| 23(General) |
- |
1000 |
|
- |
| 22(Construction verification related test) |
- |
1000 |
|
- |
| 21(Mechanical Strength Test) |
- |
1000 |
|
- |
| 20(Stability test) |
- |
1000 |
|
- |
| 19(Abnormal Operation) |
- |
1000 |
|
- |
| 18(Endurance Test requirements and tests) |
- |
1000 |
|
- |
| 17(Over Load Protection of Transformers and associated circuits) |
- |
1000 |
|
- |
| 16.3(Electric Strength (after clause 15 and 16.2)) |
- |
1000 |
|
- |
| 16.2(Leakage Current (after Clause 15)) |
- |
1000 |
|
- |
| 16.1(General) |
- |
1000 |
|
- |
| 16.0(General) |
- |
1000 |
|
- |
| 15.3(Humidity Test) |
- |
1000 |
|
- |
| 15.2(Spillage Test) |
- |
1000 |
|
- |
| 15.1(Ingress Protection test other than IPX0 (IP test)) |
- |
1000 |
|
- |
| 15.0(General) |
- |
1000 |
|
- |
| 14(Transient Over Voltages) |
- |
1000 |
|
- |
| 13.3(Electric Strength at operating temperature) |
- |
1000 |
|
- |
| 13.2(Leakage current at operating temperature) |
- |
1000 |
|
- |
| 13.1(General) |
- |
1000 |
|
- |
| 11.3(Heating) |
- |
1000 |
|
- |
| 11.2(General) |
- |
1000 |
|
- |
| 11.1(General) |
- |
1000 |
|
- |
| 10.2(Current input) |
- |
1000 |
|
- |
| 10.1(Power input) |
- |
1000 |
|
- |
| 9(Starting of motor operation test requirements and tests) |
- |
1000 |
|
- |
| 8.1.4(Protection against live parts against protective impedance) |
- |
1000 |
|
- |
| 8.1.3(Protection against live parts in visible glowing heating elements) |
- |
1000 |
|
- |
| 8.1.2(Protection against live parts in openings) |
- |
1000 |
|
- |
| 8.1.1(Protection against live parts in all positions) |
- |
1000 |
|
- |
| 7(Marking and instructions) |
- |
1000 |
|
- |
|
26 Sep, 2028 |
- "1 19.11.4.7 (Harmonics) EMI/EMC Test Test facilities not available
2 19.11.4.6 (Class 3 Voltage dips and interruptions) EMI/EMC Test Test facilities not available
3 19.11.4.5 (Immunity to conducted discharges) EMI/EMC Test Test facilities not available
4 19.11.4.4 (Surge immunity test) EMI/EMC Test Test facilities not available
5 19.11.4.3 (Fast transient bursts) EMI/EMC Test Test facilities not available
6 19.11.4.2 (Radiated fields) EMI/EMC Test Test facilities not available
7 19.11.4.1 (Electrostatic discharges) EMI/EMC Test Test facilities not available"
8 32 (Radiation Toxicity and Similar Hazards)
9 24 (Components) |