| 5341 |
BUREAU VERITAS CONSUMER PRODUCTS SERVICES INDIA PRIVATE LIMITED, NOIDA
| 8127706
| IS 302 : Part 2 : Sec 75 (2018) |
Safety of Household and Similar Electrical Appliances Part 2 Particular Requirements Section 75 Commercial Dispensing Appliances and Vending Machines |
- |
58000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 32(Radiation, toxicity and similar hazards) |
- |
0 |
|
- |
| 31(Resistance to rusting) |
- |
0 |
|
- |
| 30.2.4(Resistance to heat and fire) |
- |
0 |
|
Testing charges included in Cl. 30.1 |
| 30.2(Resistance to heat and fire) |
- |
0 |
|
Testing charges included in Cl. 30.1 |
| 30.1(Resistance to heat and fire) |
- |
3000 |
|
- |
| 29.3(Clearances, creepage distances and solid insulation) |
- |
0 |
|
Testing charges included in Cl. 29.1 |
| 29.2(Clearances, creepage distances and solid insulation) |
- |
0 |
|
Testing charges included in Cl. 29.1 |
| 29.1, Table No.- 16, Table No.- 17 & Table No.18(Clearances, creepage distances and solid insulation) |
- |
0 |
|
Testing charges included in Cl. 29.1 |
| 29.1, Table No.- 16, Table No.- 17 & Table No.18(Clearances, creepage distances and solid insulation) |
- |
2000 |
|
- |
| 28.2 to 28.4(Screws and connections) |
- |
0 |
|
Testing charges included in Cl. 28.1 |
| 28.1, Table No.-14(Screws and connections) |
- |
1000 |
|
- |
| 27.6(Provision for earthing) |
- |
0 |
|
Testing charges included in Cl. 27.5 |
| 27.5(Provision for earthing) |
- |
2000 |
|
- |
| 27.1 to 27.4(Provision for earthing) |
- |
0 |
|
Testing charges included in Cl. 27.5 |
| 26.10 & 26.11(Terminals for external conductors) |
- |
0 |
|
Testing charges included in Cl. 26.1 |
| 26.9(Terminals for external conductors) |
- |
0 |
|
Testing charges included in Cl. 26.1 |
| 26.1 to 26.8(Terminals for external conductors) |
- |
1000 |
|
- |
| 25.16 to 25.25(Supply connection and external flexible cords) |
- |
0 |
|
Testing charges included in Cl. 25.1 |
| 25.15(Supply connection and external flexible cords) |
- |
0 |
|
Testing charges included in Cl. 25.1 |
| 25.14(Supply connection and external flexible cords) |
- |
0 |
|
Testing charges included in Cl. 25.1 |
| 25.9 to 25.13(Supply connection and external flexible cords) |
- |
0 |
|
Testing charges included in Cl. 25.1 |
| 25.8, Table No.-11(Supply connection and external flexible cords) |
- |
0 |
|
Testing charges included in Cl. 25.1 |
| 25.5 to 25.7(Supply connection and external flexible cords) |
- |
0 |
|
Testing charges included in Cl. 25.1 |
| 25.4(Supply connection and external flexible cords) |
- |
0 |
|
Testing charges included in Cl. 25.1 |
| 25.3(Supply connection and external flexible cords) |
- |
0 |
|
Testing charges included in Cl. 25.1 |
| 25.2(Supply connection and external flexible cords) |
- |
0 |
|
Testing charges included in Cl. 25.1 |
| 25.1(Supply connection and external flexible cords) |
- |
1000 |
|
- |
| 24.101 to 24.103(Components) |
- |
0 |
|
Testing charges included in Cl. 24.1 |
| 24.2 to 24.6(Components) |
- |
0 |
|
Testing charges included in Cl. 24.1 |
| 24.1(Components) |
- |
3000 |
|
- |
| 23.101 to 23.102(Internal wiring) |
- |
0 |
|
Testing charges included in Cl. 23.1 |
| 23.6 to 23.10(Internal wiring) |
- |
0 |
|
Testing charges included in Cl. 23.1 |
| 23.5(Internal wiring) |
- |
0 |
|
Testing charges included in Cl. 23.1 |
| 23.4(Internal wiring) |
- |
0 |
|
Testing charges included in Cl. 23.1 |
| 23.3(Internal wiring) |
- |
0 |
|
Testing charges included in Cl. 23.1 |
| 23.1 & 23.2(Internal wiring) |
- |
2000 |
|
Testing charges included in Cl. 22.1 |
| 22.101 to 22.114(Constructions) |
- |
0 |
|
Testing charges included in Cl. 22.1 |
| 22.13 to 22.48(Constructions) |
- |
0 |
|
Testing charges included in Cl. 22.1 |
| 22.12(Constructions) |
- |
0 |
|
Testing charges included in Cl. 22.1 |
| 22.11(Constructions) |
- |
0 |
|
Testing charges included in Cl. 22.1 |
| 22.11(Constructions) |
- |
0 |
|
Testing charges included in Cl. 22.1 |
| 22.7 to 22.10(Constructions) |
- |
0 |
|
Testing charges included in Cl. 22.1 |
| 22.6(Constructions) |
- |
0 |
|
Testing charges included in Cl. 22.1 |
| 22.5(Constructions) |
- |
0 |
|
Testing charges included in Cl. 22.1 |
| 22.4(Constructions) |
- |
0 |
|
Testing charges included in Cl. 22.1 |
| 22.3(Constructions) |
- |
0 |
|
Testing charges included in Cl. 22.1 |
| 22.2(Constructions) |
- |
0 |
|
Testing charges included in Cl. 22.1 |
| 22.1(Constructions) |
- |
6000 |
|
- |
| 21.2(MECHANICAL STRENGTH) |
- |
0 |
|
Testing charges included in Cl. 21.1 |
| 21.1(MECHANICAL STRENGTH) |
- |
1500 |
|
- |
| 20.2(Stability and mechanical hazards) |
- |
1000 |
|
- |
| 20.1(Stability and mechanical hazards) |
- |
1000 |
|
- |
| 19.101 and 19.102(ABNORMAL OPERATION) |
- |
0 |
|
Testing charges included in Cl. 19.1 |
| 19.1 to 19.13, Table No. - 9(ABNORMAL OPERATION) |
- |
5000 |
|
- |
| 17(Overload protection of transformers and associated circuits) |
- |
4000 |
|
- |
| 16.3(Insulation resistance test) |
- |
0 |
|
Testing charges included in Cl. 16.1 |
| 16.3(Electric strength test) |
- |
0 |
|
Testing charges included in Cl. 16.1 |
| 16.1 & 16.2(Leakage current test) |
- |
3000 |
|
- |
| 15.102(Moisture resistance) |
- |
0 |
|
Testing charges included in Cl. 15.1 |
| 15.102(Moisture resistance) |
- |
0 |
|
Testing charges included in Cl. 15.1 |
| 15.101(Moisture resistance) |
- |
0 |
|
Testing charges included in Cl. 15.1 |
| 15.3(Moisture resistance) |
- |
0 |
|
Testing charges included in Cl. 15.1 |
| 15.2(Moisture resistance) |
- |
0 |
|
Testing charges included in Cl. 15.1 |
| 15.1(Moisture resistance) |
- |
4500 |
|
- |
| 14, Table No.- 6 & Table No.-16(Transient over voltages) |
- |
2000 |
|
- |
| 13.3 and Table No.- 4(Electric strength test) |
- |
1500 |
|
- |
| 13.1, 13.2(Leakage current test) |
- |
1500 |
|
- |
| 11.1 to 11.8, Table No.-3(Heating) |
- |
4500 |
|
- |
| 10.1 & 10.2 -Table No. 1, Table No. 2(Power Input and Current) |
- |
2000 |
|
- |
| 8.1.5(Protection against access to live parts) |
- |
0 |
|
Testing charges included in Cl. 8.1 |
| 8.1.4(Protection against access to live parts) |
- |
0 |
|
Testing charges included in Cl. 8.1 |
| 8.1.3(Protection against access to live parts) |
- |
0 |
|
Testing charges included in Cl. 8.1 |
| 8.1.2(Protection against access to live parts) |
- |
0 |
|
Testing charges included in Cl. 8.1 |
| 8.1, 8.1.1 & 8.2(Protection against access to live parts) |
- |
2000 |
|
- |
| 7.14(Legibility & Durability of Markings test) |
- |
0 |
|
Testing charges included in Cl. 7.1 |
| 7.1 to 7.13, 7.15, 7.16(Marking) |
- |
2000 |
|
- |
| 32(Radiation, toxicity and similar hazards) |
- |
0 |
|
- |
| 31(Resistance to rusting) |
- |
0 |
|
- |
| 30.2.4(Resistance to heat and fire) |
- |
0 |
|
Testing charges included in Cl. 30.1 |
| 30.2(Resistance to heat and fire) |
- |
0 |
|
Testing charges included in Cl. 30.1 |
| 30.1(Resistance to heat and fire) |
- |
0 |
|
Testing charges included in Cl. 30.1 |
| 29.3(Clearances, creepage distances and solid insulation) |
- |
0 |
|
Testing charges included in Cl. 29.1 |
| 29.2(Clearances, creepage distances and solid insulation) |
- |
0 |
|
Testing charges included in Cl. 29.1 |
| 29.2(Clearances, creepage distances and solid insulation) |
- |
0 |
|
Testing charges included in Cl. 29.1 |
| 29.1, Table No.- 16, Table No.- 17 & Table No.18(Clearances, creepage distances and solid insulation) |
- |
0 |
|
Testing charges included in Cl. 29.1 |
| 29.1, Table No.- 16, Table No.- 17 & Table No.18(Clearances, creepage distances and solid insulation) |
- |
0 |
|
Testing charges included in Cl. 29.1 |
| 28.2 to 28.4(Screws and connections) |
- |
0 |
|
Testing charges included in Cl. 28.1 |
| 28.1, Table No.-14(Screws and connections) |
- |
0 |
|
Testing charges included in Cl. 28.1 |
| 27.6(Provision for earthing) |
- |
0 |
|
Testing charges included in Cl. 27.5 |
| 27.5(Provision for earthing) |
- |
0 |
|
Testing charges included in Cl. 27.5 |
| 27.1 to 27.4(Provision for earthing) |
- |
0 |
|
Testing charges included in Cl. 27.5 |
| 26.10 & 26.11(Terminals for external conductors) |
- |
0 |
|
Testing charges included in Cl. 26.1 |
| 26.9(Terminals for external conductors) |
- |
0 |
|
Testing charges included in Cl. 26.1 |
| 26.1 to 26.8(Terminals for external conductors) |
- |
0 |
|
Testing charges included in Cl. 26.1 |
| 25.16 to 25.25(Supply connection and external flexible cords) |
- |
0 |
|
Testing charges included in Cl. 25.1 |
| 25.15(Supply connection and external flexible cords) |
- |
0 |
|
Testing charges included in Cl. 25.1 |
| 25.14(Supply connection and external flexible cords) |
- |
0 |
|
Testing charges included in Cl. 25.1 |
| 25.9 to 25.13(Supply connection and external flexible cords) |
- |
0 |
|
Testing charges included in Cl. 25.1 |
| 25.8, Table No.-11(Supply connection and external flexible cords) |
- |
0 |
|
Testing charges included in Cl. 25.1 |
| 25.5 to 25.7(Supply connection and external flexible cords) |
- |
0 |
|
Testing charges included in Cl. 25.1 |
| 25.4(Supply connection and external flexible cords) |
- |
0 |
|
Testing charges included in Cl. 25.1 |
| 25.3(Supply connection and external flexible cords) |
- |
0 |
|
Testing charges included in Cl. 25.1 |
| 25.2(Supply connection and external flexible cords) |
- |
0 |
|
Testing charges included in Cl. 25.1 |
| 25.1(Supply connection and external flexible cords) |
- |
0 |
|
Testing charges included in Cl. 25.1 |
| 24.101 to 24.103(Components) |
- |
0 |
|
Testing charges included in Cl. 24.1 |
| 24.2 to 24.6(Components) |
- |
0 |
|
Testing charges included in Cl. 24.1 |
| 24.1(Components) |
- |
0 |
|
Testing charges included in Cl. 24.1 |
| 23.101 to 23.102(Internal wiring) |
- |
0 |
|
Testing charges included in Cl. 23.1 |
| 23.6 to 23.10(Internal wiring) |
- |
0 |
|
Testing charges included in Cl. 23.1 |
| 23.5(Internal wiring) |
- |
0 |
|
Testing charges included in Cl. 23.1 |
| 23.4(Internal wiring) |
- |
0 |
|
Testing charges included in Cl. 23.1 |
| 23.3(Internal wiring) |
- |
0 |
|
Testing charges included in Cl. 23.1 |
| 23.1 & 23.2(Internal wiring) |
- |
0 |
|
Testing charges included in Cl. 23.1 |
| 22.101 to 22.114(Constructions) |
- |
0 |
|
Testing charges included in Cl. 22.1 |
| 22.13 to 22.48(Constructions) |
- |
0 |
|
Testing charges included in Cl. 22.1 |
| 22.12(Constructions) |
- |
0 |
|
Testing charges included in Cl. 22.1 |
| 22.11(Constructions) |
- |
0 |
|
Testing charges included in Cl. 22.1 |
| 22.11(Constructions) |
- |
0 |
|
Testing charges included in Cl. 22.1 |
| 22.7 to 22.10(Constructions) |
- |
0 |
|
Testing charges included in Cl. 22.1 |
| 22.6(Constructions) |
- |
0 |
|
Testing charges included in Cl. 22.1 |
| 22.5(Constructions) |
- |
0 |
|
Testing charges included in Cl. 22.1 |
| 22.4(Constructions) |
- |
0 |
|
Testing charges included in Cl. 22.1 |
| 22.3(Constructions) |
- |
0 |
|
Testing charges included in Cl. 22.1 |
| 22.2(Constructions) |
- |
0 |
|
Testing charges included in Cl. 22.1 |
| 22.1(Constructions) |
- |
0 |
|
Testing charges included in Cl. 22.1 |
| 21.2(MECHANICAL STRENGTH) |
- |
0 |
|
- |
| 21.1(MECHANICAL STRENGTH) |
- |
0 |
|
- |
| 20.2(Stability and mechanical hazards) |
- |
0 |
|
- |
| 20.1(Stability and mechanical hazards) |
- |
0 |
|
- |
| 19.101 and 19.102(ABNORMAL OPERATION) |
- |
0 |
|
Testing charges included in Cl. 19.1 |
| 19.1 to 19.13, Table No. - 9(ABNORMAL OPERATION) |
- |
0 |
|
Testing charges included in Cl. 19.1 |
| 17(Overload protection of transformers and associated circuits) |
- |
0 |
|
Testing charges included in Cl. 17 |
| 16.3(Insulation resistance test) |
- |
0 |
|
Testing charges included in Cl. 16.1 |
| 16.3(Electric strength test) |
- |
0 |
|
Testing charges included in Cl. 16.1 |
| 16.1 & 16.2(Leakage current test) |
- |
0 |
|
Testing charges included in Cl. 16.1 |
| 15.102(Moisture resistance) |
- |
0 |
|
Testing charges included in Cl. 15.1 |
| 15.102(Moisture resistance) |
- |
0 |
|
Testing charges included in Cl. 15.1 |
| 15.101(Moisture resistance) |
- |
0 |
|
Testing charges included in Cl. 15.1 |
| 15.3(Moisture resistance) |
- |
0 |
|
Testing charges included in Cl. 15.1 |
| 15.2(Moisture resistance) |
- |
0 |
|
Testing charges included in Cl. 15.1 |
| 15.1(Moisture resistance) |
- |
0 |
|
Testing charges included in Cl. 15.1 |
| 14, Table No.- 6 & Table No.-16(Transient over voltages) |
- |
0 |
|
Testing charges included in Cl. 14 |
| 13.3 and Table No.- 4(Electric strength test) |
- |
0 |
|
Testing charges included in Cl. 13.1 |
| 13.1, 13.2(Leakage current test) |
- |
0 |
|
Testing charges included in Cl. 13.1 |
| 11.1 to 11.8, Table No.-3(Heating) |
- |
0 |
|
- |
| 10.1 & 10.2 -Table No. 1, Table No. 2(Power Input and Current) |
- |
0 |
|
- |
| 8.1.5(Protection against access to live parts) |
- |
0 |
|
Testing charges included in Cl. 8.1 |
| 8.1.4(Protection against access to live parts) |
- |
0 |
|
Testing charges included in Cl. 8.1 |
| 8.1.3(Protection against access to live parts) |
- |
0 |
|
Testing charges included in Cl. 8.1 |
| 8.1.2(Protection against access to live parts) |
- |
0 |
|
Testing charges included in Cl. 8.1 |
| 8.1, 8.1.1 & 8.2(Protection against access to live parts) |
- |
0 |
|
Testing charges included in Cl. 8.1 |
| 7.14(Legibility & Durability of Markings test) |
- |
0 |
|
Testing charges included in Cl. 7.1 |
| 7.1 to 7.13, 7.15, 7.16(Marking) |
- |
0 |
|
Testing charges included in Cl. 7.1 |
| 29.2(Clearances, creepage distances and solid insulation) |
- |
0 |
|
Testing charges included in Cl. 29.1 |
|
- |
- Included w.e.f.20.06.2025
Exclusion
(EMI/EMC)Cl 19.11.4.1 TO Cl 19.11.4.7 |
| 5342 |
ABB Global Industries and Services Pvt. Ltd. - Low voltage breakers and switches testing laboratory
| 6189726
| IS/IEC 60947 : Part 4 : Sec 1 (2018) |
Low-Voltage switchgear and controlgear : Part 4-1 Contactors and motor starters electromechanical contactors and motor-Starters |
Contcators and motor starters, 25A to 630 A |
430350 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 9.3.3.2(Operating limits) |
- |
15400 |
|
Estimated tests charges do not include GST. Final charges will include GST at the prevailing rates. Charges for one sample of one rating |
| 9.3.3.2.1.2(Coil power consumption) |
- |
11500 |
|
Estimated tests charges do not include GST. Final charges will include GST at the prevailing rates. Charges for one sample of one rating |
| 9.3.3.2.1.3(Pole impedance) |
- |
11500 |
|
Estimated tests charges do not include GST. Final charges will include GST at the prevailing rates. Charges for one sample of one rating |
| 9.3.3.3.1(Ambient air temperature) |
- |
11500 |
|
Estimated tests charges do not include GST. Final charges will include GST at the prevailing rates. Charges for one sample of one rating |
| 9.3.3.3.2(Measurement of the temperature of parts) |
- |
70270 |
|
Charges for one rating upto 200A ₹19450 201A to 1000A ₹26810/- 1001A to 2000A ₹36110 2001A to 3000A ₹46230/- 3001A to 4000A ₹58270/- 4001A to 7000A ₹70270/- per rating without GST |
| 9.3.3.3.3(Temperature-rise of a part) |
- |
70270 |
|
Charges for one rating upto 200A ₹19450 201A to 1000A ₹26810/- 1001A to 2000A ₹36110 2001A to 3000A ₹46230/- 3001A to 4000A ₹58270/- 4001A to 7000A ₹70270/- per rating without GST |
| 9.3.3.3.4(Temperature-rise of the main circuit) |
- |
70270 |
|
Charges for one rating upto 200A ₹19450 201A to 1000A ₹26810/- 1001A to 2000A ₹36110 2001A to 3000A ₹46230/- 3001A to 4000A ₹58270/- 4001A to 7000A ₹70270/- per rating without GST |
| 9.3.3.3.5(Temperature-rise of control circuits) |
- |
11500 |
|
Estimated tests charges do not include GST. Final charges will include GST at the prevailing rates. Charges for one sample of one rating |
| 9.3.3.3.6(Temperature-rise of coils and electromagnets) |
- |
11500 |
|
Estimated tests charges do not include GST. Final charges will include GST at the prevailing rates. Charges for one sample of one rating |
| 9.3.3.3.7(Temperature-rise of auxiliary circuits) |
- |
11500 |
|
Estimated tests charges do not include GST. Final charges will include GST at the prevailing rates. Charges for one sample of one rating |
| 9.3.3.6(Operational performance capability) |
- |
51750 |
|
per shift |
| 9.3.5(Overload current withstand capability of contactors) |
- |
11500 |
|
Estimated tests charges do not include GST. Final charges will include GST at the prevailing rates. Charges for one sample of one rating |
| 9.3.6.3(Dielectric tests) |
- |
14390 |
|
Estimated tests charges do not include GST. Final charges will include GST at the prevailing rates. Charges for one rating SP ₹3000 SPN/DP ₹8000 TP ₹11000 FP ₹14390 |
| 8.2.4 of IEC 60947-1:2007 (Sequence 5)(Verification of Mechanical properties of terminals) |
- |
11500 |
|
- |
| Annex C of IEC 60947-1:2007 (Sequence 5)(Verification of Degree of protection of enclosed contactors and starters) |
- |
11500 |
|
- |
| 9.3.3.2.2(Relays and releases) |
- |
11500 |
|
- |
| 9.3.3.3.8(Temperature-rise of starting resistors for rheostatic rotor starters) |
- |
11500 |
|
Estimated tests charges do not include GST. Final charges will include GST at the prevailing rates. Charges for one sample of one rating |
| 9.3.6.2(Operation and operating limits) |
- |
11500 |
|
- |
|
07 Nov, 2028 |
- 1. Verification of rated marking and breaking capacities, change over ability and reversibility, where applicable(9.3.3.5) above 725V and 250A
2. Verification of conventional operational performance(9.3.3.6) above 725V and 250A
3. (Seq III) performance under short circuit conditions (9.3.4) |
| 5343 |
ABB Global Industries and Services Pvt. Ltd. - Low voltage breakers and switches testing laboratory
| 6189726
| IS/IEC 60947 : Part 5 : Sec 1 (2016) |
Low-Voltage Switchgear And Control Gear : Part 5-1 Control Circuit Devices And Switching Elements Electromechanical Control Circuit Devices |
Control circuit devices and switching elements, 10A |
357070 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 8.3.3.4(Dielectric properties) |
- |
51340 |
|
Test Charges will vary depending on the rating of the sample Test charge applicable will be intimated through a proforma invoice (Rate quoated is excluding GST) |
| 8.3.3.4(Dielectric properties) |
- |
51340 |
|
Test Charges will vary depending on the rating of the sample Test charge applicable will be intimated through a proforma invoice (Rate quoated is excluding GST) |
| 8.2.4(Mechanical and electrical properties of terminals) |
- |
25000 |
|
Test Charges will vary depending on the rating of the sample Test charge applicable will be intimated through a proforma invoice (Rate quoated is excluding GST) |
| 8.3.3.5.6 b(Dielectric verification) |
- |
14390 |
|
Estimated tests charges do not include GST. Final charges will include GST at the prevailing rates. Charges for one rating SP ₹3000 SPN/DP ₹8000 TP ₹11000 FP ₹14390 |
| 8.3.3.5.4(Making and breaking capacities of switching elements under abnormal conditions) |
- |
35000 |
|
Per shift |
| 8.2.5 (Sequence 5)(Verification of actuating force (or moment)) |
- |
5000 |
|
per sample |
| 7.1.4(Clearances and creepage distances) |
- |
5000 |
|
per sample |
| 7.2.4.1(Making and breaking capacities) |
- |
0 |
|
- |
| 7.2.3(Dielectric properties) |
- |
51340 |
|
Test Charges will vary depending on the rating of the sample Test charge applicable will be intimated through a proforma invoice (Rate quoated is excluding GST) |
| 8.2.1.1.1(Glow-wire test) |
- |
15000 |
|
Per sample |
| 8.2.1.1.2(Flammability, hot wire ignition and arc ignition tests (on materials)) |
- |
15000 |
|
Per sample |
| 8.2.4(Mechanical and electrical properties of terminals) |
- |
25000 |
|
Test Charges will vary depending on the rating of the sample Test charge applicable will be intimated through a proforma invoice (Rate quoated is excluding GST) |
| 8.2.4.2(Tests of mechanical strength of terminals) |
- |
15000 |
|
Per sample |
| 8.2.4.3(Testing for damage to and accidental loosening of conductors (flexion test)) |
- |
15000 |
|
Per sample |
| 8.2.4.4(Pull-out test) |
- |
15000 |
|
Per sample |
| 8.3.1(Degree of protection of enclosed control circuit devices) |
- |
60000 |
|
- |
| H.8.7("Verification of
electromagnetic
compatibility") |
- |
0 |
|
- |
| 8.2.4.5(Test for insertability of unprepared round copper conductors having the maximum cross-section) |
- |
15000 |
|
per sample |
| 8.2.5(Verification of actuating force (or moment)) |
- |
5000 |
|
per sample |
| 7.1.2.2(Glow-wire testing) |
- |
15000 |
|
Per sample |
| Cl-7.3(Electromagnetic compatibility (EMC)) |
- |
0 |
|
- |
| 7.1.4 of IEC 60947-1:2007 (Sequence 6)(Measurement of Clearances and creepage distances) |
- |
5000 |
|
per sample |
| 8.3.3.5.3(Making and breaking capacities of switching elements under abnormal conditions) |
- |
0 |
|
- |
| 7.2.4.1(Making and breaking capacities) |
- |
0 |
|
- |
| 7.2.4.1(Making and breaking capacities) |
- |
0 |
|
- |
| Annex C of IEC 60947-1:2007 (Sequence 5)(Degree of protection of enclosed control circuit devices) |
- |
5000 |
|
- |
| 8.3.3.5(Making and breaking capacities) |
- |
0 |
|
- |
| 7.2.3(Dielectric properties) |
- |
51340 |
|
Test Charges will vary depending on the rating of the sample Test charge applicable will be intimated through a proforma invoice (Rate quoated is excluding GST) |
| 8.2.1.1(Test of resistance to abnormal heat and fire) |
- |
15000 |
|
Per sample |
| 8.2.4.5(Test for insertability of unprepared round copper conductors having the maximum cross-section) |
- |
15000 |
|
Per Sample |
| 8.2.1.1.1(Glow-wire test) |
- |
15000 |
|
Per sample |
| 8.2.4.4(Pull-out test) |
- |
15000 |
|
Per sample |
| 8.2.4.3(Testing for damage to and accidental loosening of conductors (flexion test)) |
- |
15000 |
|
Per sample |
| 8.2.4.2(Tests of mechanical strength of terminals) |
- |
15000 |
|
Per sample |
| 8.3.3.5(Making and breaking capacities) |
- |
0 |
|
- |
|
07 Nov, 2028 |
- Seq I Operating limits of contactor relays, if applicable (8.3.3.2), Temperature rise (8.3.3.3),
Seq II Making and breaking capacities of switching elements under normal conditions (8.3.3.5.3)
Seq IV Performance under conditional short circuit current (8.3.4)
Seq VI Verification of Limitation of rotation of Rotary Switch (8.2.6) |
| 5344 |
ABB Global Industries and Services Pvt. Ltd. - Low voltage breakers and switches testing laboratory
| 6189726
| IS/IEC 60947 : Part 2 (2016) |
Low - Voltage switchgear and controlgear: Part 2 circuit - Breakers (First Revision) |
Circuit Breakers, 25A to 630A |
1191815 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 8.3.3.2(Tripping limits and characteristics) |
- |
86940 |
|
Estimated tests charges do not include GST. Final charges will include GST at the prevailing rates. Charges for one rating SP ₹45540 SPN ₹49680 DP ₹53820 TP ₹70380 TPN ₹82800 FP ₹86940 considering as adjustable release in each case |
| 8.3.3.3(Test of dielectric properties) |
- |
77950 |
|
Estimated tests charges do not include GST. Final charges will include GST at the prevailing rates. Charges for one rating SP ₹20100 SPN/DP ₹48450 TP ₹63160 FP ₹77950 |
| 8.3.3.4(Mechanical operation and operational performance capability) |
- |
100625 |
|
Estimated tests charges do not include GST. Final charges will include GST at the prevailing rates. Charges for one rating SP, SPN/DP, TPN & FP |
| 8.3.3.5(Overload performance) |
- |
94050 |
|
Estimated tests charges do not include GST. Final charges will include GST at the prevailing rates. Charges for one rating SP, SPN/DP & TPN |
| 8.3.3.6(Verification of dielectric withstand) |
- |
26200 |
|
Estimated tests charges do not include GST. Final charges will include GST at the prevailing rates. Charges for one rating SP ₹5960 SPN/DP ₹16700 TP ₹21430 FP ₹26200 |
| 8.3.3.7(Verification of temperature-rise) |
- |
37100 |
|
Charges for one rating upto 200A ₹7900, 201A to 1000A ₹12200, 1001A to 2000A ₹17500, 2001A to 3000A ₹23300/- 3001A to 4000A ₹30160/-, 4001A to 7000A ₹37100/- per rating without GST |
| 8.3.3.8(Verification of Overload releases) |
- |
21850 |
|
Estimated tests charges do not include GST. Final charges will include GST at the prevailing rates. Charges for one rating SP, SPN/DP, TPN & FP ₹21850 |
| 8.3.3.9(Verification of undervoltage and shunt releases) |
- |
7950 |
|
Estimated tests charges do not include GST. Final charges will include GST at the prevailing rates. Charges for one rating SP, SPN/DP, TPN & FP ₹7950 |
| 8.3.3.10(Verification of main contact position) |
- |
7950 |
|
Estimated tests charges do not include GST. Final charges will include GST at the prevailing rates. Charges for one rating SP, SPN/DP, TPN & FP ₹7950 |
| 8.3.4.3(Verification of operational performance capability) |
- |
47050 |
|
Estimated tests charges do not include GST. Final charges will include GST at the prevailing rates. Charges for one rating SP, SPN/DP, TPN & FP upto 630A ₹32100 SP, SPN/DP, TPN & FP above 630A ₹47050 |
| 8.3.8.5(Verification of operational performance capability) |
- |
47050 |
|
Estimated tests charges do not include GST. Final charges will include GST at the prevailing rates. Charges for one rating SP, SPN/DP, TPN & FP upto 630A ₹32100 SP, SPN/DP, TPN & FP above 630A ₹47050 |
| 8.4.4(Verification of the operation of undervoltage and shunt releases) |
- |
7950 |
|
Estimated tests charges do not include GST. Final charges will include GST at the prevailing rates. Charges for one rating SP, SPN/DP, TPN & FP ₹7950 |
| 8.4.6(Dielectric tests) |
- |
77950 |
|
Estimated tests charges do not include GST. Final charges will include GST at the prevailing rates. Charges for one rating SP ₹20100 SPN/DP ₹48500 TP ₹63200 FP ₹77950 |
| 8.3.4.4(Verification of dielectric withstand) |
- |
26200 |
|
Estimated tests charges do not include GST. Final charges will include GST at the prevailing rates. Charges for one rating SP ₹5960 SPN/DP ₹16700 TP ₹21430 FP ₹26200 |
| 8.3.5.4(Verification of dielectric withstand) |
- |
26200 |
|
Estimated tests charges do not include GST. Final charges will include GST at the prevailing rates. Charges for one rating SP ₹5960 SPN/DP ₹16700 TP ₹21430 FP ₹26200 |
| 8.3.6.6(Verification of dielectric withstand) |
- |
26200 |
|
Estimated tests charges do not include GST. Final charges will include GST at the prevailing rates. Charges for one rating SP ₹5960 SPN/DP ₹16700 TP ₹21430 FP ₹26200 |
| 8.3.7.4(Verification of dielectric withstand) |
- |
26200 |
|
Estimated tests charges do not include GST. Final charges will include GST at the prevailing rates. Charges for one rating SP ₹5960 SPN/DP ₹16700 TP ₹21430 FP ₹26200 |
| 8.3.7.8(Verification of dielectric withstand) |
- |
26200 |
|
Estimated tests charges do not include GST. Final charges will include GST at the prevailing rates. Charges for one rating SP ₹5960 SPN/DP ₹16700 TP ₹21430 FP ₹26200 |
| 8.3.8.6(Verification of dielectric withstand) |
- |
26200 |
|
Estimated tests charges do not include GST. Final charges will include GST at the prevailing rates. Charges for one rating SP ₹5960 SPN/DP ₹16700 TP ₹21430 FP ₹26200 |
| 8.3.4.5(Verifiation of temperature-rise) |
- |
37100 |
|
Charges for one rating upto 200A ₹7900, 201A to 1000A ₹12200, 1001A to 2000A ₹17500, 2001A to 3000A ₹23300/- 3001A to 4000A ₹30160/-, 4001A to 7000A ₹37100/- per rating without GST |
| 8.3.6.4(Verification of temperature-rise) |
- |
37100 |
|
Charges for one rating upto 200A ₹7900, 201A to 1000A ₹12200, 1001A to 2000A ₹17500, 2001A to 3000A ₹23300/- 3001A to 4000A ₹30160/-, 4001A to 7000A ₹37100/- per rating without GST |
| 8.3.7.3(Verification of temperature-rise) |
- |
37100 |
|
Charges for one rating upto 200A ₹7900, 201A to 1000A ₹12200, 1001A to 2000A ₹17500, 2001A to 3000A ₹23300/- 3001A to 4000A ₹30160/-, 4001A to 7000A ₹37100/- per rating without GST |
| 8.3.8.7(Verification of temperature-rise) |
- |
37100 |
|
Charges for one rating upto 200A ₹7900, 201A to 1000A ₹12200, 1001A to 2000A ₹17500, 2001A to 3000A ₹23300/- 3001A to 4000A ₹30160/-, 4001A to 7000A ₹37100/- per rating without GST |
| 8.3.4.6(Verification of Overload releases) |
- |
21850 |
|
Estimated tests charges do not include GST. Final charges will include GST at the prevailing rates. Charges for one rating SP, SPN/DP, TPN & FP ₹21850 |
| 8.3.5.2(Verification of Overload releases) |
- |
21850 |
|
Estimated tests charges do not include GST. Final charges will include GST at the prevailing rates. Charges for one rating SP, SPN/DP, TPN & FP ₹21850 |
| 8.3.5.5(Verification of Overload releases) |
- |
21850 |
|
Estimated tests charges do not include GST. Final charges will include GST at the prevailing rates. Charges for one rating SP, SPN/DP, TPN & FP ₹21850 |
| 8.3.6.2(Verification of Overload releases) |
- |
21850 |
|
Estimated tests charges do not include GST. Final charges will include GST at the prevailing rates. Charges for one rating SP, SPN/DP, TPN & FP ₹21850 |
| 8.3.6.7(Verification of Overload releases) |
- |
21850 |
|
Estimated tests charges do not include GST. Final charges will include GST at the prevailing rates. Charges for one rating SP, SPN/DP, TPN & FP ₹21850 |
| 8.3.7.5(Verification of Overload releases) |
- |
21850 |
|
Estimated tests charges do not include GST. Final charges will include GST at the prevailing rates. Charges for one rating SP, SPN/DP, TPN & FP ₹21850 |
| 8.3.7.9(Verification of Overload releases) |
- |
21850 |
|
Estimated tests charges do not include GST. Final charges will include GST at the prevailing rates. Charges for one rating SP, SPN/DP, TPN & FP ₹21850 |
| 8.3.8.2(Verification of Overload releases) |
- |
21850 |
|
Estimated tests charges do not include GST. Final charges will include GST at the prevailing rates. Charges for one rating SP, SPN/DP, TPN & FP ₹21850 |
| 8.3.8.8(Verification of Overload releases) |
- |
21850 |
|
Estimated tests charges do not include GST. Final charges will include GST at the prevailing rates. Charges for one rating SP, SPN/DP, TPN & FP ₹21850 |
| 7.3 Annexure J Table J.1(Electrostatic discharges) |
- |
9775 |
|
- |
| 7.3 Annexure J Table J.1("Electrical fast transients/bursts") |
- |
9775 |
|
- |
| 7.3 Annexure J Table J.1(Surges) |
- |
18400 |
|
- |
| 7.3 Annexure J Table J.3("Conducted RF disturbances 150 kHz to 30 MHz") |
- |
11000 |
|
- |
| 8.3.4.4(verification of dielectric withstand (sequnce II)) |
- |
26200 |
|
Estimated tests charges do not include GST. Final charges will include GST at the prevailing rates. Charges for one rating SP ₹5960 SPN/DP ₹16700 TP ₹21430 FP ₹26200 |
| 8.3.4.5(verification of temperature-rise (sequence II)) |
- |
37100 |
|
Charges for one rating upto 200A ₹7900, 201A to 1000A ₹12200, 1001A to 2000A ₹17500, 2001A to 3000A ₹23300/- 3001A to 4000A ₹30160/-, 4001A to 7000A ₹37100/- per rating without GST |
| 8.3.4.6(verification of overload releases (sequence II)) |
- |
21850 |
|
Estimated tests charges do not include GST. Final charges will include GST at the prevailing rates. Charges for one rating SP, SPN/DP, TPN & FP ₹21850 |
| 8.3.5.2(verification of overload releases (sequence III)) |
- |
21850 |
|
Estimated tests charges do not include GST. Final charges will include GST at the prevailing rates. Charges for one rating SP, SPN/DP, TPN & FP ₹21850 |
| 8.3.5.4(verification of dielectric withstand (sequnce III)) |
- |
26200 |
|
Estimated tests charges do not include GST. Final charges will include GST at the prevailing rates. Charges for one rating SP ₹5960 SPN/DP ₹16700 TP ₹21430 FP ₹26200 |
| 8.3.5.5(verification of overload releases (sequence III)) |
- |
21850 |
|
Estimated tests charges do not include GST. Final charges will include GST at the prevailing rates. Charges for one rating SP, SPN/DP, TPN & FP ₹21850 |
| 8.3.6.2(verification of overload releases (sequence IV)) |
- |
21850 |
|
Estimated tests charges do not include GST. Final charges will include GST at the prevailing rates. Charges for one rating SP, SPN/DP, TPN & FP ₹21850 |
| 8.3.6.4(verification of temperature-rise (sequence IV)) |
- |
37100 |
|
Charges for one rating upto 200A ₹7900, 201A to 1000A ₹12200, 1001A to 2000A ₹17500, 2001A to 3000A ₹23300/- 3001A to 4000A ₹30160/-, 4001A to 7000A ₹37100/- per rating without GST |
| 8.3.6.6(verification of dielectric withstand (sequence IV)) |
- |
26200 |
|
Estimated tests charges do not include GST. Final charges will include GST at the prevailing rates. Charges for one rating SP ₹5960 SPN/DP ₹16700 TP ₹21430 FP ₹26200 |
| 8.3.6.7(verification of overload releases (sequence IV)) |
- |
21850 |
|
Estimated tests charges do not include GST. Final charges will include GST at the prevailing rates. Charges for one rating SP, SPN/DP, TPN & FP ₹21850 |
| 8.3.7.3((stage 1) verification of temperature-rise (sequence V)) |
- |
37100 |
|
Charges for one rating upto 200A ₹7900, 201A to 1000A ₹12200, 1001A to 2000A ₹17500, 2001A to 3000A ₹23300/- 3001A to 4000A ₹30160/-, 4001A to 7000A ₹37100/- per rating without GST |
| 8.3.7.4((stage 1) verification of dielectric withstand (sequence V)) |
- |
26200 |
|
Estimated tests charges do not include GST. Final charges will include GST at the prevailing rates. Charges for one rating SP ₹5960 SPN/DP ₹16700 TP ₹21430 FP ₹26200 |
| 8.3.7.5((stage 2) verification of overload releases (sequence V)) |
- |
21850 |
|
Estimated tests charges do not include GST. Final charges will include GST at the prevailing rates. Charges for one rating SP, SPN/DP, TPN & FP ₹21850 |
| 8.3.7.8((stage 2) verification of dielectric withstand (sequence V)) |
- |
26200 |
|
Estimated tests charges do not include GST. Final charges will include GST at the prevailing rates. Charges for one rating SP ₹5960 SPN/DP ₹16700 TP ₹21430 FP ₹26200 |
| 8.3.7.9((stage 2) verification of overload releases (sequence V)) |
- |
21850 |
|
Estimated tests charges do not include GST. Final charges will include GST at the prevailing rates. Charges for one rating SP, SPN/DP, TPN & FP ₹21850 |
| 8.3.8.2(verification of overload releases (sequence VI)) |
- |
21850 |
|
Estimated tests charges do not include GST. Final charges will include GST at the prevailing rates. Charges for one rating SP, SPN/DP, TPN & FP ₹21850 |
| 8.3.8.6(verification of dielectric withstand (sequence VI)) |
- |
26200 |
|
Estimated tests charges do not include GST. Final charges will include GST at the prevailing rates. Charges for one rating SP ₹5960 SPN/DP ₹16700 TP ₹21430 FP ₹26200 |
| 8.3.8.5(verification of operational performance capability (sequence VI)) |
- |
47050 |
|
Estimated tests charges do not include GST. Final charges will include GST at the prevailing rates. Charges for one rating SP, SPN/DP, TPN & FP upto 630A ₹32100 SP, SPN/DP, TPN & FP above 630A ₹47050 |
| 8.3.8.7(verification of temperature-rise (sequence VI)) |
- |
37100 |
|
Charges for one rating upto 200A ₹7900, 201A to 1000A ₹12200, 1001A to 2000A ₹17500, 2001A to 3000A ₹23300/- 3001A to 4000A ₹30160/-, 4001A to 7000A ₹37100/- per rating without GST |
| 8.3.8.8(verification of overload releases (sequence VI)) |
- |
21850 |
|
Estimated tests charges do not include GST. Final charges will include GST at the prevailing rates. Charges for one rating SP, SPN/DP, TPN & FP ₹21850 |
| 8.3.4.3(verification of operational performance capability (sequence II)) |
- |
47050 |
|
Estimated tests charges do not include GST. Final charges will include GST at the prevailing rates. Charges for one rating SP, SPN/DP, TPN & FP upto 630A ₹32100 SP, SPN/DP, TPN & FP above 630A ₹47050 |
|
07 Nov, 2028 |
- 8.3.3.5 Overload performance above test voltage 725v and test current 200A (Devices rated beyond 32A)
Seq II 8.3.4.2 (Rated service short circuit breaking capacity)
Seq III 8.3.5.3 (Rated ultimate short-circuit breaking capacity)
Seq IV 8.3.6.3 (Rated short-time withstand current),
8.3.6.5 (Short-circuit breaking capacity at maximum short-time withstand current)
Seq V 8.3.7.2 (Short-circuit at the selectivity limit current), 8.3.7.6 (Short-circuit at 1,1 times take-over current), 8.3.7.7 (Short-circuit at ultimate short-circuit breaking capacity)
Co-ordination between circuit breaker and another circuit protective device associated in the same circuit (Annex A), Circuit breakers incorporating residual current protection (Annex B), Items subjected to agreement between manufacturer and user (Annex E), Additional test for circuit breakers with electronic overload protection (Annex F), Power Loss (Annex G), Test sequence for circuit breakers for IT systems(Annex H), radiated radio frequency electromagnetic Fields (Annex J.2.3), Conducted disturbances induced by RF fields (Annex J.2.6) |
| 5345 |
Classic Testing & Research Centre (B17), Noida
| 8180826
| IS 302 : Part 2 : Sec 32 (1994) |
Safety of household and similar electrical appliances: Part 2 particular requirements: Sec 32 massage appliances |
- |
45000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl. 32 302-2-32 : 1994(Radiation Hazards) |
- |
5000 |
|
- |
| Cl. 31 302-2-32 : 1994(Resistance to Rusting) |
- |
5000 |
|
- |
| Cl. 30 302-2-32 : 1994(Resistance to Heat Fire & Tracking ) |
- |
5000 |
|
- |
| Cl. 29 302-2-32 : 1994(Clearances, Creepage Distances & Solid insulation ) |
- |
5000 |
|
- |
| Cl. 28 302-2-32 : 1994(Screws & Connections) |
- |
5000 |
|
- |
| Cl. 27 302-2-32 : 1994(Provision for Earthing ) |
- |
5000 |
|
- |
| Cl. 26 302-2-32 : 1994(Terminals for External conductors ) |
- |
5000 |
|
- |
| Cl. 25 302-2-32 : 1994(Supply Connection & External Flexible Cords) |
- |
5000 |
|
- |
| Cl. 24 302-2-32 : 1994(Components) |
- |
5000 |
|
- |
| Cl. 23 302-2-32 : 1994(Internal Wiring) |
- |
5000 |
|
- |
| Cl. 22 302-2-32 : 1994(Construction ) |
- |
5000 |
|
- |
| Cl. 21 302-2-32 : 1994(Mechanical strength) |
- |
5000 |
|
- |
| Cl. 20 302-2-32 : 1994(Stability & Mechanical Hazards) |
- |
5000 |
|
- |
| Cl. 19 302-2-32 : 1994(Abnormal Operation ) |
- |
5000 |
|
- |
| Cl. 18 302-2-32 : 1994(Endurance) |
- |
5000 |
|
- |
| Cl. 17 302-2-32 : 1994(Overload Protection of Transformers and Associated Circuit) |
- |
5000 |
|
- |
| Cl. 16 302-2-32 : 1994(Leakage Current & Electric Strength at Operating Temperature (After Humidity Treatment)) |
- |
5000 |
|
- |
| Cl. 15 302-2-32: 1994(Moisture Resistance Test ) |
- |
5000 |
|
- |
| Cl. 14 302-2-32 : 1994(Radio and television interference suppression / Transient over voltages) |
- |
5000 |
|
- |
| Cl. 13 302-2-32 : 1994(Leakage Current & Electric Strength at Operating Temperature) |
- |
5000 |
|
- |
| Cl. 11 302-2-32 : 1994(Temperature Rise) |
- |
5000 |
|
- |
| Cl. 10 302-2-32 : 1994(Power Input and Current ) |
- |
5000 |
|
- |
| Cl. 9 302-2-32 : 1994(Protection Against Electric Shock) |
- |
5000 |
|
- |
| Cl. 8 302-2-32 : 1994(Starting of motor operated appliances) |
- |
5000 |
|
- |
| Cl. 7 302-2-32 : 1994(Marking) |
- |
5000 |
|
- |
| (CI. 6 IS 302-2-32 : 1994(Classification ) |
- |
5000 |
|
- |
| 19.11.4.1(Electrostatic discharges) |
- |
5000 |
|
- |
| 19.11.4.3(Fast transient bursts) |
- |
5000 |
|
- |
| 19.11.4.4(Surge immunity test) |
- |
5000 |
|
- |
| 19.11.4.6(Class 3 Voltage dips and interruptions) |
- |
5000 |
|
- |
| 19.11.4.7(Harmonics) |
- |
5000 |
|
- |
|
15 Oct, 2027 |
- Included w.e.f.13.05.2025
Exclusion
Cl 19.11.4.2 (Radiated fields)
Cl 19.11.4.5 (Immunity to conducted discharges) |
| 5346 |
National Test House (NR) - NTH, Ghaziabad
| 8101304
| IS 14490 (2024) |
Plain Copier Paper â Specification (Second Revision) |
- |
16000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 5.1.1(plain copier paper) |
- |
500 |
|
- |
| 5.1.2(k,) |
- |
500 |
|
- |
| 5.2(Moisture) |
- |
500 |
|
- |
| 5.3(Grammage (Substance)) |
- |
1000 |
|
- |
| 5.4(Thickness) |
- |
500 |
|
- |
| 5.5(Size) |
- |
1000 |
|
- |
| 5.7(Conditioning specified) |
- |
1000 |
|
- |
| 5.8(Additional Requirements for Eco-Mark) |
- |
1000 |
|
- |
| 5.6, Table 1, i(ISO brightness, percent, Min) |
- |
1000 |
|
- |
| 5.6, Table 1, ii(Opacity, percent, Min) |
- |
1000 |
|
- |
| 5.6, Table 1, iii(One minute cobb test, both sides, g/m2 , Max) |
- |
1000 |
|
- |
| 5.6, Table 1, iv(Surface strength, Dennison (Wax Pick)) |
- |
1000 |
|
- |
| 5.6, Table 1, v(Smoothness for both sides (Bendsten), ml/min, Max) |
- |
1000 |
|
- |
| 5.6, Table 1, vi(Ash content (at 900 °C), percent by mass, Max) |
- |
1000 |
|
- |
| 5.6, Table 1, vii(Taber stiffness, Min:
Machine direction, Cross direction) |
- |
1000 |
|
- |
| 5.6, Table 1, viii(Tear Index, mN.m2 /g, Min:
Machine direction, Cross direction) |
- |
1000 |
|
- |
| 5.6, Table 1, ix(Tensile index, N.m/g, Min:
Machine direction, Cross direction) |
- |
1000 |
|
- |
| 6(PACKING AND MARKING) |
- |
1000 |
|
- |
| 5.1.1(plain copier paper) |
- |
0 |
|
- |
| 5.1.2(k,) |
- |
0 |
|
- |
| 5.2(Moisture) |
- |
0 |
|
- |
| 5.3(Grammage (Substance)) |
- |
0 |
|
- |
| 5.4(Thickness) |
- |
0 |
|
- |
| 5.5(Size) |
- |
0 |
|
- |
| 5.7(Conditioning specified) |
- |
0 |
|
- |
| 5.8(Additional Requirements for Eco-Mark) |
- |
0 |
|
- |
| 5.6, Table 1, i(ISO brightness, percent, Min) |
- |
0 |
|
- |
| 5.6, Table 1, ii(Opacity, percent, Min) |
- |
0 |
|
- |
| 5.6, Table 1, iii(One minute cobb test, both sides, g/m2 , Max) |
- |
0 |
|
- |
| 5.6, Table 1, iv(Surface strength, Dennison (Wax Pick)) |
- |
0 |
|
- |
| 5.6, Table 1, v(Smoothness for both sides (Bendsten), ml/min, Max) |
- |
0 |
|
- |
| 5.6, Table 1, vi(Ash content (at 900 °C), percent by mass, Max) |
- |
0 |
|
- |
| 5.6, Table 1, vii(Taber stiffness, Min:
Machine direction, Cross direction) |
- |
0 |
|
- |
| 5.6, Table 1, viii(Tear Index, mN.m2 /g, Min:
Machine direction, Cross direction) |
- |
0 |
|
- |
| 5.6, Table 1, ix(Tensile index, N.m/g, Min:
Machine direction, Cross direction) |
- |
0 |
|
- |
| 6(PACKING AND MARKING) |
- |
0 |
|
- |
| 5.1.1(plain copier paper) |
- |
0 |
|
- |
| 5.1.2(k,) |
- |
0 |
|
- |
| 5.2(Moisture) |
- |
0 |
|
- |
| 5.3(Grammage (Substance)) |
- |
0.01 |
|
- |
| 5.4(Thickness) |
- |
0 |
|
- |
| 5.5(Size) |
- |
0 |
|
- |
| 5.7(Conditioning specified) |
- |
0 |
|
- |
| 5.8(Additional Requirements for Eco-Mark) |
- |
0 |
|
- |
| 5.6, Table 1, i(ISO brightness, percent, Min) |
- |
0 |
|
- |
| 5.6, Table 1, ii(Opacity, percent, Min) |
- |
0 |
|
- |
| 5.6, Table 1, iii(One minute cobb test, both sides, g/m2 , Max) |
- |
0 |
|
- |
| 5.6, Table 1, iv(Surface strength, Dennison (Wax Pick)) |
- |
0.01 |
|
- |
| 5.6, Table 1, v(Smoothness for both sides (Bendsten), ml/min, Max) |
- |
0 |
|
- |
| 5.6, Table 1, vi(Ash content (at 900 °C), percent by mass, Max) |
- |
0 |
|
- |
| 5.6, Table 1, vii(Taber stiffness, Min:
Machine direction, Cross direction) |
- |
0 |
|
- |
| 5.6, Table 1, viii(Tear Index, mN.m2 /g, Min:
Machine direction, Cross direction) |
- |
0 |
|
- |
| 5.6, Table 1, ix(Tensile index, N.m/g, Min:
Machine direction, Cross direction) |
- |
0 |
|
- |
| 6(PACKING AND MARKING) |
- |
0 |
|
- |
| 5.1.1(plain copier paper) |
- |
0 |
|
- |
| 5.1.2(k,) |
- |
0 |
|
- |
| 5.2(Moisture) |
- |
0 |
|
- |
| 5.3(Grammage (Substance)) |
- |
0 |
|
- |
| 5.4(Thickness) |
- |
0 |
|
- |
| 5.5(Size) |
- |
0 |
|
- |
| 5.7(Conditioning specified) |
- |
0 |
|
- |
| 5.8(Additional Requirements for Eco-Mark) |
- |
0 |
|
- |
| 5.6, Table 1, i(ISO brightness, percent, Min) |
- |
0 |
|
- |
| 5.6, Table 1, ii(Opacity, percent, Min) |
- |
0 |
|
- |
| 5.6, Table 1, iii(One minute cobb test, both sides, g/m2 , Max) |
- |
0 |
|
- |
| 5.6, Table 1, iv(Surface strength, Dennison (Wax Pick)) |
- |
0 |
|
- |
| 5.6, Table 1, v(Smoothness for both sides (Bendsten), ml/min, Max) |
- |
0 |
|
- |
| 5.6, Table 1, vi(Ash content (at 900 °C), percent by mass, Max) |
- |
0 |
|
- |
| 5.6, Table 1, vii(Taber stiffness, Min:
Machine direction, Cross direction) |
- |
0 |
|
- |
| 5.6, Table 1, viii(Tear Index, mN.m2 /g, Min:
Machine direction, Cross direction) |
- |
0 |
|
- |
| 5.6, Table 1, ix(Tensile index, N.m/g, Min:
Machine direction, Cross direction) |
- |
0 |
|
- |
| 6(PACKING AND MARKING) |
- |
0 |
|
- |
|
26 Oct, 2028 |
- Included w.e.f.28.05.2025 |
| 5347 |
Testtex India Laboratories Pvt. Ltd., Mumbai
| 7126506
| IS 17786 (2022) |
Medical Textiles Underpad Specification |
Small, Medium, Large, Extra Large |
14000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Clause 5, Table 1(Type and Sizes) |
- |
500 |
|
Complete Testing Charges- Rs 14,000 + GST (10 % Discount to BIS for Complete Testing) |
| Clause 6(WORKMANSHIP AND FINISH) |
- |
500 |
|
- |
| Clause 8.1(pH Value) |
- |
500 |
|
- |
| Clause 8.2, Table 2, (i)(Minimum absorption capacity (ml)) |
- |
1000 |
|
- |
| Clause 8.2, Table 2, (ii)(Absorption Time, s/ml, Max) |
- |
500 |
|
- |
| Clause 8.2, Table 2, (iii)(Retention Capacity #, Min) |
- |
1000 |
|
- |
| Clause 8.3.1(Bacterial and Fungal Bioburden) |
- |
5000 |
|
- |
| Clause 8.3.2(Test for Common Skin Pathogen - Staphylococcus Aureus) |
- |
2500 |
|
- |
| Clause 4.2(Top Cover or Top Sheet) |
- |
500 |
|
- |
| Clause 4.3(Absorbent Core) |
- |
500 |
|
- |
| Clause 4.4(Outer Protective Barrier or Back Sheet) |
- |
500 |
|
- |
| Clause 4.5(Adhesive) |
- |
500 |
|
- |
| Clause 7.0(Washing, Drying and handling Instruction) |
- |
500 |
|
- |
| Clause 9.0(Marking) |
- |
0 |
|
- |
| Clause 5, Table 1(Type and Sizes) |
- |
500 |
|
- |
| Clause 6(WORKMANSHIP AND FINISH) |
- |
500 |
|
- |
| Clause 8.1(pH Value) |
- |
500 |
|
- |
| Clause 8.2, Table 2, (i)(Minimum absorption capacity (ml)) |
- |
1000 |
|
- |
| Clause 8.2, Table 2, (ii)(Absorption Time, s/ml, Max) |
- |
500 |
|
- |
| Clause 8.2, Table 2, (iii)(Retention Capacity #, Min) |
- |
1000 |
|
- |
| Clause 8.3.1(Bacterial and Fungal Bioburden) |
- |
5000 |
|
- |
| Clause 8.3.2(Test for Common Skin Pathogen - Staphylococcus Aureus) |
- |
2500 |
|
- |
| Clause 4.2(Top Cover or Top Sheet) |
- |
500 |
|
- |
| Clause 4.3(Absorbent Core) |
- |
500 |
|
- |
| Clause 4.4(Outer Protective Barrier or Back Sheet) |
- |
500 |
|
- |
| Clause 4.5(Adhesive) |
- |
500 |
|
- |
| Clause 7.0(Washing, Drying and handling Instruction) |
- |
500 |
|
- |
| Clause 9.0(Marking) |
- |
0 |
|
- |
| Clause 5, Table 1(Type and Sizes) |
- |
500 |
|
- |
| Clause 6(WORKMANSHIP AND FINISH) |
- |
500 |
|
- |
| Clause 8.1(pH Value) |
- |
500 |
|
- |
| Clause 8.2, Table 2, (i)(Minimum absorption capacity (ml)) |
- |
1000 |
|
- |
| Clause 8.2, Table 2, (ii)(Absorption Time, s/ml, Max) |
- |
500 |
|
- |
| Clause 8.2, Table 2, (iii)(Retention Capacity #, Min) |
- |
1000 |
|
- |
| Clause 8.3.1(Bacterial and Fungal Bioburden) |
- |
5000 |
|
- |
| Clause 8.3.2(Test for Common Skin Pathogen - Staphylococcus Aureus) |
- |
2500 |
|
- |
| Clause 4.2(Top Cover or Top Sheet) |
- |
0 |
|
- |
| Clause 4.3(Absorbent Core) |
- |
0 |
|
- |
| Clause 4.4(Outer Protective Barrier or Back Sheet) |
- |
0 |
|
- |
| Clause 4.5(Adhesive) |
- |
0 |
|
- |
| Clause 7.0(Washing, Drying and handling Instruction) |
- |
0 |
|
- |
| Clause 9.0(Marking) |
- |
0 |
|
- |
| Clause 5, Table 1(Type and Sizes) |
- |
500 |
|
- |
| Clause 6(WORKMANSHIP AND FINISH) |
- |
500 |
|
- |
| Clause 8.1(pH Value) |
- |
500 |
|
- |
| Clause 8.2, Table 2, (i)(Minimum absorption capacity (ml)) |
- |
1000 |
|
- |
| Clause 8.2, Table 2, (ii)(Absorption Time, s/ml, Max) |
- |
500 |
|
- |
| Clause 8.2, Table 2, (iii)(Retention Capacity #, Min) |
- |
1000 |
|
- |
| Clause 8.3.1(Bacterial and Fungal Bioburden) |
- |
2500 |
|
- |
| Clause 8.3.2(Test for Common Skin Pathogen - Staphylococcus Aureus) |
- |
2500 |
|
- |
| Clause 4.2(Top Cover or Top Sheet) |
- |
500 |
|
- |
| Clause 4.3(Absorbent Core) |
- |
500 |
|
- |
| Clause 4.4(Outer Protective Barrier or Back Sheet) |
- |
500 |
|
- |
| Clause 4.5(Adhesive) |
- |
500 |
|
- |
| Clause 7.0(Washing, Drying and handling Instruction) |
- |
500 |
|
- |
| Clause 9.0(Marking) |
- |
0 |
|
- |
| Clause 5, Table 1(Type and Sizes) |
- |
500 |
|
- |
| Clause 6(WORKMANSHIP AND FINISH) |
- |
500 |
|
- |
| Clause 8.1(pH Value) |
- |
500 |
|
- |
| Clause 8.2, Table 2, (i)(Minimum absorption capacity (ml)) |
- |
1000 |
|
- |
| Clause 8.2, Table 2, (ii)(Absorption Time, s/ml, Max) |
- |
500 |
|
- |
| Clause 8.2, Table 2, (iii)(Retention Capacity #, Min) |
- |
1000 |
|
- |
| Clause 8.3.1(Bacterial and Fungal Bioburden) |
- |
5000 |
|
- |
| Clause 8.3.2(Test for Common Skin Pathogen - Staphylococcus Aureus) |
- |
2500 |
|
- |
| Clause 4.2(Top Cover or Top Sheet) |
- |
500 |
|
- |
| Clause 4.3(Absorbent Core) |
- |
500 |
|
- |
| Clause 4.4(Outer Protective Barrier or Back Sheet) |
- |
500 |
|
- |
| Clause 4.5(Adhesive) |
- |
500 |
|
- |
| Clause 7.0(Washing, Drying and handling Instruction) |
- |
500 |
|
- |
| Clause 9.0(Marking) |
- |
0 |
|
- |
| Clause 5, Table 1(Type and Sizes) |
- |
500 |
|
- |
| Clause 6(WORKMANSHIP AND FINISH) |
- |
500 |
|
- |
| Clause 8.1(pH Value) |
- |
500 |
|
- |
| Clause 8.2, Table 2, (i)(Minimum absorption capacity (ml)) |
- |
1000 |
|
- |
| Clause 8.2, Table 2, (ii)(Absorption Time, s/ml, Max) |
- |
500 |
|
- |
| Clause 8.2, Table 2, (iii)(Retention Capacity #, Min) |
- |
1000 |
|
- |
| Clause 8.3.1(Bacterial and Fungal Bioburden) |
- |
5000 |
|
- |
| Clause 8.3.2(Test for Common Skin Pathogen - Staphylococcus Aureus) |
- |
2500 |
|
- |
| Clause 4.2(Top Cover or Top Sheet) |
- |
500 |
|
- |
| Clause 4.3(Absorbent Core) |
- |
500 |
|
- |
| Clause 4.4(Outer Protective Barrier or Back Sheet) |
- |
500 |
|
- |
| Clause 4.5(Adhesive) |
- |
500 |
|
- |
| Clause 7.0(Washing, Drying and handling Instruction) |
- |
500 |
|
- |
| Clause 9.0(Marking) |
- |
0 |
|
- |
| Clause 5, Table 1(Type and Sizes) |
- |
500 |
|
- |
| Clause 6(WORKMANSHIP AND FINISH) |
- |
500 |
|
- |
| Clause 8.1(pH Value) |
- |
500 |
|
- |
| Clause 8.2, Table 2, (i)(Minimum absorption capacity (ml)) |
- |
1000 |
|
- |
| Clause 8.2, Table 2, (ii)(Absorption Time, s/ml, Max) |
- |
500 |
|
- |
| Clause 8.2, Table 2, (iii)(Retention Capacity #, Min) |
- |
1000 |
|
- |
| Clause 8.3.1(Bacterial and Fungal Bioburden) |
- |
5000 |
|
- |
| Clause 8.3.2(Test for Common Skin Pathogen - Staphylococcus Aureus) |
- |
2500 |
|
- |
| Clause 4.2(Top Cover or Top Sheet) |
- |
500 |
|
- |
| Clause 4.3(Absorbent Core) |
- |
500 |
|
- |
| Clause 4.4(Outer Protective Barrier or Back Sheet) |
- |
500 |
|
- |
| Clause 4.5(Adhesive) |
- |
500 |
|
- |
| Clause 7.0(Washing, Drying and handling Instruction) |
- |
500 |
|
- |
| Clause 9.0(Marking) |
- |
0 |
|
- |
| Clause 5, Table 1(Type and Sizes) |
- |
500 |
|
- |
| Clause 6(WORKMANSHIP AND FINISH) |
- |
500 |
|
- |
| Clause 8.1(pH Value) |
- |
500 |
|
- |
| Clause 8.2, Table 2, (i)(Minimum absorption capacity (ml)) |
- |
1000 |
|
- |
| Clause 8.2, Table 2, (ii)(Absorption Time, s/ml, Max) |
- |
500 |
|
- |
| Clause 8.2, Table 2, (iii)(Retention Capacity #, Min) |
- |
1000 |
|
- |
| Clause 8.3.1(Bacterial and Fungal Bioburden) |
- |
5000 |
|
- |
| Clause 8.3.2(Test for Common Skin Pathogen - Staphylococcus Aureus) |
- |
2500 |
|
- |
| Clause 4.2(Top Cover or Top Sheet) |
- |
500 |
|
- |
| Clause 4.3(Absorbent Core) |
- |
500 |
|
- |
| Clause 4.4(Outer Protective Barrier or Back Sheet) |
- |
500 |
|
- |
| Clause 4.5(Adhesive) |
- |
500 |
|
- |
| Clause 7.0(Washing, Drying and handling Instruction) |
- |
500 |
|
- |
| Clause 9.0(Marking) |
- |
0 |
|
- |
| Clause 5, Table 1(Type and Sizes) |
- |
500 |
|
- |
| Clause 6(WORKMANSHIP AND FINISH) |
- |
500 |
|
- |
| Clause 8.1(pH Value) |
- |
500 |
|
- |
| Clause 8.2, Table 2, (i)(Minimum absorption capacity (ml)) |
- |
1000 |
|
- |
| Clause 8.2, Table 2, (ii)(Absorption Time, s/ml, Max) |
- |
500 |
|
- |
| Clause 8.2, Table 2, (iii)(Retention Capacity #, Min) |
- |
1000 |
|
- |
| Clause 8.3.1(Bacterial and Fungal Bioburden) |
- |
5000 |
|
- |
| Clause 8.3.2(Test for Common Skin Pathogen - Staphylococcus Aureus) |
- |
2500 |
|
- |
| Clause 4.2(Top Cover or Top Sheet) |
- |
500 |
|
- |
| Clause 4.3(Absorbent Core) |
- |
500 |
|
- |
| Clause 4.4(Outer Protective Barrier or Back Sheet) |
- |
500 |
|
- |
| Clause 4.5(Adhesive) |
- |
500 |
|
- |
| Clause 7.0(Washing, Drying and handling Instruction) |
- |
500 |
|
- |
| Clause 9.0(Marking) |
- |
0 |
|
- |
| Clause 5, Table 1(Type and Sizes) |
- |
500 |
|
- |
| Clause 6(WORKMANSHIP AND FINISH) |
- |
500 |
|
- |
| Clause 8.1(pH Value) |
- |
500 |
|
- |
| Clause 8.2, Table 2, (i)(Minimum absorption capacity (ml)) |
- |
1000 |
|
- |
| Clause 8.2, Table 2, (ii)(Absorption Time, s/ml, Max) |
- |
500 |
|
- |
| Clause 8.2, Table 2, (iii)(Retention Capacity #, Min) |
- |
1000 |
|
- |
| Clause 8.3.1(Bacterial and Fungal Bioburden) |
- |
5000 |
|
- |
| Clause 8.3.2(Test for Common Skin Pathogen - Staphylococcus Aureus) |
- |
2500 |
|
- |
| Clause 4.2(Top Cover or Top Sheet) |
- |
500 |
|
- |
| Clause 4.3(Absorbent Core) |
- |
500 |
|
- |
| Clause 4.4(Outer Protective Barrier or Back Sheet) |
- |
500 |
|
- |
| Clause 4.5(Adhesive) |
- |
500 |
|
- |
| Clause 7.0(Washing, Drying and handling Instruction) |
- |
500 |
|
- |
| Clause 9.0(Marking) |
- |
0 |
|
- |
| Clause 5, Table 1(Type and Sizes) |
- |
500 |
|
- |
| Clause 6(WORKMANSHIP AND FINISH) |
- |
500 |
|
- |
| Clause 8.1(pH Value) |
- |
500 |
|
- |
| Clause 8.2, Table 2, (i)(Minimum absorption capacity (ml)) |
- |
1000 |
|
- |
| Clause 8.2, Table 2, (ii)(Absorption Time, s/ml, Max) |
- |
500 |
|
- |
| Clause 8.2, Table 2, (iii)(Retention Capacity #, Min) |
- |
1000 |
|
- |
| Clause 8.3.1(Bacterial and Fungal Bioburden) |
- |
5000 |
|
- |
| Clause 8.3.2(Test for Common Skin Pathogen - Staphylococcus Aureus) |
- |
2500 |
|
- |
| Clause 4.2(Top Cover or Top Sheet) |
- |
500 |
|
- |
| Clause 4.3(Absorbent Core) |
- |
500 |
|
- |
| Clause 4.4(Outer Protective Barrier or Back Sheet) |
- |
500 |
|
- |
| Clause 4.5(Adhesive) |
- |
500 |
|
- |
| Clause 7.0(Washing, Drying and handling Instruction) |
- |
500 |
|
- |
| Clause 9.0(Marking) |
- |
0 |
|
- |
|
- |
- Included w.e.f 26.05.2025
Exclusion: Clause 8.4 (" Biocompatibility Evaluation — Irritation and Skin Sensitization, Cytotoxicity (Optional)") |
| 5348 |
Arbro Pharmaceuticals Private Limited
| 8116816
| IS 15410 (2003) |
Containers for packaging of natural mineral water and packaged drinking water - Specification |
Commercial Grade |
16350 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4.1(Material) |
- |
0 |
|
No Discount |
| 4.6.2 Annex A(Transparency) |
- |
400 |
|
No Discount |
| 4.6.4, clause 8 of IS:2798:1998(Drop test ) |
- |
300 |
|
No Discount |
| 4.6.5(MIGRATION TEST) |
- |
1000 |
|
No Discount |
| 4.6.6.b (chem)(Water Potability Test
(b) Taste) |
- |
200 |
|
No Discount |
| 4.2(Design, Shape & Dimension ) |
- |
100 |
|
No Discount |
| 4.3(Workmanship, Finish & Appearance) |
- |
0 |
|
No Discount |
| Cl. 4.4 (a)(Capacity) |
- |
49.98 |
|
No Discount |
| 4.4 (b)(Brimful Capacity) |
- |
200 |
|
No Discount |
| 4.5, IS:2798:1998(Wall thickness- Top , in mm ) |
- |
200 |
|
No Discount |
| 4.5, IS:2798:1998(Wall thickness- Middle , in mm) |
- |
200 |
|
No Discount |
| 4.5, IS:2798:1998(Wall thickness- Bottom, in mm) |
- |
200 |
|
No Discount |
| 4.6.6.a (chem)(Water Potability Test
(a) Odour) |
- |
200 |
|
No Discount |
| 4.6.5.1.a(Colour migration Test (Container)) |
- |
300 |
|
No Discount |
| 4.6.3, clause 6 of IS:2798:1998(Leakage test- a. Closure leakage ) |
- |
133.33 |
|
No Discount |
| 4.6.3, clause 6 of IS:2798:1998(Leakage test- b. Vibration leakage) |
- |
133.33 |
|
No Discount |
| 4.6.3, clause 6 of IS:2798:1998(Leakage test- c. Air pressure leakage) |
- |
133.33 |
|
No Discount |
| Cl. 4.6.5 (chem)(Cl. 4.6.5 Overall migration (Caps)) |
- |
300 |
|
No Discount |
| 4.6.5 (chem)(c. Colour Migration (Cap)) |
- |
300 |
|
No Discount |
| 4.6.1(Environmental Stress-Crack Resistance) |
- |
0 |
|
Not Applicable (Parameter Removed from IS 15410). |
| Cl.4.6.7.2 and 4.6.7.3, Table 3, (i)(Barium) |
- |
300 |
|
Charges applicable for container only. In case of both Cap and container testing charges are 600 Rs. |
| Cl.4.6.7.2 and 4.6.7.3, Table 3, (ii)(Cobalt) |
- |
300 |
|
Charges applicable for container only. In case of both Cap and container testing charges are 600 Rs. |
| Cl.4.6.7.2 and 4.6.7.3, Table 3, (iii)(Copper) |
- |
300 |
|
Charges applicable for container only. In case of both Cap and container testing charges are 600 Rs. |
| Cl.4.6.7.2 and 4.6.7.3, Table 3, (iv)(Iron) |
- |
300 |
|
Charges applicable for container only. In case of both Cap and container testing charges are 600 Rs. |
| Cl.4.6.7.2 and 4.6.7.3, Table 3, (v)(Lithium) |
- |
300 |
|
Charges applicable for container only. In case of both Cap and container testing charges are 600 Rs. |
| Cl.4.6.7.2 and 4.6.7.3, Table 3, (vi)(Manganese) |
- |
300 |
|
Charges applicable for container only. In case of both Cap and container testing charges are 600 Rs. |
| Cl.4.6.7.2 and 4.6.7.3, Table 3, (vii)(Zinc) |
- |
300 |
|
Charges applicable for container only. In case of both Cap and container testing charges are 600 Rs. |
| Cl.4.6.7.2 and 4.6.7.3, Table 3, (viii)(Antimony) |
- |
300 |
|
Charges applicable for container only. In case of both Cap and container testing charges are 600 Rs. |
| Cl.4.6.7.2 and 4.6.7.3, Table 3, (ix)(Phthalic acid, bis(2-ethylhexyl) ester (DEHP)) |
- |
3600 |
|
Charges applicable for container only. In case of both Cap and container testing charges are 7200 Rs. |
|
14 Jan, 2029 |
- - |
| 5349 |
Institute for Auto Parts and Hand Tools Technology, Ludhiana
| 9126034
| IS 4432 (1988) |
Specification for case hardening steels (First Revision) |
All Grade/Type/Size/Designation as per IS 4432 |
40180 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| TABLE-1 (Clause-5)( CARBON) |
- |
100 |
|
- |
| TABLE-1 (Clause-5)(SULPHUR) |
- |
100 |
|
- |
| TABLE-1 (Clause-5)(PHOSPHURS) |
- |
100 |
|
- |
| TABLE-1 (Clause-5)(MANGANESE) |
- |
100 |
|
- |
| TABLE-1 (Clause-5)(SILICON) |
- |
100 |
|
- |
| TABLE-1 (Clause-5)( ALUMINIUM) |
- |
120 |
|
- |
| TABLE-1 (Clause-5)(Chromium) |
- |
120 |
|
- |
| TABLE-1 (Clause-5)(Molybdenum) |
- |
120 |
|
- |
| TABLE-1 (Clause-5)(NIOBIUM) |
- |
120 |
|
- |
| TABLE-1 (Clause-5)(VANADIUM) |
- |
120 |
|
- |
| TABLE-1 (Clause-5)(TITANIUM) |
- |
120 |
|
- |
| Cl. 5(Copper) |
- |
360 |
|
Copper = 120/-
Nickle= 120/-
Tin= 120/- |
| 11(Dimensional Tolerances) |
- |
1200 |
|
- |
| 4(Freedom from Defects) |
- |
500 |
|
- |
| 7(Hardness) |
- |
400 |
|
- |
| 8(Mechanical testing) |
- |
4200 |
|
- |
| 8.4(Impact testing) |
- |
4000 |
|
- |
| 9(Grain Size) |
- |
400 |
|
- |
| 10(Inclusion rating) |
- |
400 |
|
- |
| 14(Additional test) |
- |
26000 |
|
Blank Hardening- Rs. 6000/-
Hot upset test -Rs. 6000/-
Hardenability test- 5000/-
Blue fracture test - 4500/-
Microstructure- 500/-
Macro etch test - 1000/-
Step machined test- 1000/-
MPI testing - 1000/-
UT- 1000/- |
| TABLE-1 (Clause-5)(NITROGEN) |
- |
1500 |
|
- |
|
17 Feb, 2028 |
- - |
| 5350 |
Institute for Auto Parts and Hand Tools Technology, Ludhiana
| 9126034
| IS 704 (1984) |
Specification for crow - Bars and claw - Bars (Second Revision) |
All Grade/Type/Size/Designationasper IS704:1984 RA 2021 |
5440 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 3 Table-1 to 9(Shapes And Dimensions-Width across flats ) |
- |
1200 |
|
- |
| 6(Hardness) |
- |
400 |
|
- |
| 7(Manufacture and Finish) |
- |
500 |
|
- |
| 8.1(Drop Test) |
- |
500 |
|
- |
| 8.2(Static Load Test) |
- |
1000 |
|
- |
| 8.3(Falling weight test) |
- |
500 |
|
- |
| 5.0(Material testing) |
- |
0 |
|
- |
|
17 Feb, 2028 |
- - |
| 5351 |
REACT COMPLIANCE AND TESTING LABORATORIES LLP, BENGALURU
| 6130526
| IS/IEC 61683 (1999) |
Photovoltaic systems - Power conditioners - Procedure for measuring efficiency |
- |
100000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4(Efficiency measurement conditions) |
- |
60000 |
|
- |
| 5(Efficiency calculations) |
- |
20000 |
|
- |
| 6(Efficiency test circuits) |
- |
0 |
|
- |
| 7(Loss measurement) |
- |
20000 |
|
- |
| 4.1(DC power source for testing) |
- |
0 |
|
- |
| 4.2(Temperature) |
- |
0 |
|
- |
| 4.3(Output voltage and frequency) |
- |
0 |
|
- |
| 4.4(Input voltage) |
- |
0 |
|
- |
| 4.5(Ripple and distortion) |
- |
0 |
|
- |
| 4.6(Resistive loads/utility grid) |
- |
0 |
|
- |
| 4.7(Reactive loads) |
- |
0 |
|
- |
| 4.8(Resistive plus non-linear loads) |
- |
0 |
|
- |
| 4.9(Complex loads) |
- |
0 |
|
- |
| Annex A(Power conditioner description) |
- |
0 |
|
- |
| Annex B(Power efficiency and conversion factor) |
- |
0 |
|
- |
| Annex C(Weighted average energy efficiency) |
- |
0 |
|
- |
| Annex D(Derivation of efficiency tolerance in Table 2) |
- |
0 |
|
- |
| 4(Efficiency measurement conditions) |
- |
60000 |
|
- |
| 5(Efficiency calculations) |
- |
20000 |
|
- |
| 6(Efficiency test circuits) |
- |
0 |
|
- |
| 7(Loss measurement) |
- |
20000 |
|
- |
| 4.1(DC power source for testing) |
- |
0 |
|
- |
| 4.2(Temperature) |
- |
0 |
|
- |
| 4.3(Output voltage and frequency) |
- |
0 |
|
- |
| 4.4(Input voltage) |
- |
0 |
|
- |
| 4.5(Ripple and distortion) |
- |
0 |
|
- |
| 4.6(Resistive loads/utility grid) |
- |
0 |
|
- |
| 4.7(Reactive loads) |
- |
0 |
|
- |
| 4.8(Resistive plus non-linear loads) |
- |
0 |
|
- |
| 4.9(Complex loads) |
- |
0 |
|
- |
| Annex A(Power conditioner description) |
- |
0 |
|
- |
| Annex B(Power efficiency and conversion factor) |
- |
0 |
|
- |
| Annex C(Weighted average energy efficiency) |
- |
0 |
|
- |
| Annex D(Derivation of efficiency tolerance in Table 2) |
- |
0 |
|
- |
| 4(Efficiency measurement conditions) |
- |
60000 |
|
- |
| 5(Efficiency calculations) |
- |
20000 |
|
- |
| 6(Efficiency test circuits) |
- |
20000 |
|
- |
| 7(Loss measurement) |
- |
20000 |
|
- |
| 4.1(DC power source for testing) |
- |
10000 |
|
- |
| 4.2(Temperature) |
- |
10000 |
|
- |
| 4.3(Output voltage and frequency) |
- |
10000 |
|
- |
| 4.4(Input voltage) |
- |
10000 |
|
- |
| 4.5(Ripple and distortion) |
- |
10000 |
|
- |
| 4.6(Resistive loads/utility grid) |
- |
10000 |
|
- |
| 4.7(Reactive loads) |
- |
10000 |
|
- |
| 4.8(Resistive plus non-linear loads) |
- |
10000 |
|
- |
| 4.9(Complex loads) |
- |
10000 |
|
- |
| Annex A(Power conditioner description) |
- |
10000 |
|
- |
| Annex B(Power efficiency and conversion factor) |
- |
10000 |
|
- |
| Annex C(Weighted average energy efficiency) |
- |
10000 |
|
- |
| Annex D(Derivation of efficiency tolerance in Table 2) |
- |
10000 |
|
- |
|
10 Mar, 2027 |
- Included w.e.f 20.06.2025 |
| 5352 |
BUREAU VERITAS CONSUMER PRODUCTS SERVICES INDIA PRIVATE LIMITED, NOIDA
| 8127706
| IS 302 : Part 2 : Sec 30 (2007) |
Safety of household and similar electrical appliances: Part 2 particular requirements: Sec 30 room heaters (First Revision) |
- |
60500 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl.6 (Classification) |
- |
0 |
|
- |
| Cl.6 (Classification) |
- |
0 |
|
- |
| Cl.7 & IS:302-1:2008(Marking and Instructions) |
- |
2000 |
|
- |
| Cl.7 & IS:302-1:2008(Marking and Instructions) |
- |
0 |
|
Testing charges included in Cl. 7 |
| Cl.7 & IS:302-1:2008(Marking and Instructions) |
- |
0 |
|
Testing charges included in Cl. 7 |
| Cl.7 & IS:302-1:2008(Marking and Instructions) |
- |
0 |
|
Testing charges included in Cl. 7 |
| Cl.7 & IS:302-1:2008(Marking and Instructions) |
- |
0 |
|
Testing charges included in Cl. 7 |
| Cl.7 & IS:302-1:2008(Marking and Instructions) |
- |
0 |
|
Testing charges included in Cl. 7 |
| Cl.7 & IS:302-1:2008(Marking and Instructions) |
- |
0 |
|
Testing charges included in Cl. 7 |
| Cl.7 & IS:302-1:2008(Marking and Instructions) |
- |
0 |
|
Testing charges included in Cl. 7 |
| Cl.7 & IS:302-1:2008(Marking and Instructions) |
- |
0 |
|
Testing charges included in Cl. 7 |
| Cl.7(Marking and Instructions) |
- |
0 |
|
Testing charges included in Cl. 7 |
| Cl.7(Marking and Instructions) |
- |
0 |
|
Testing charges included in Cl. 7 |
| Cl.7(Marking and Instructions) |
- |
0 |
|
Testing charges included in Cl. 7 |
| Cl.7.3(Marking and Instructions) |
- |
0 |
|
Testing charges included in Cl. 7 |
| Cl.7.3(Marking and Instructions) |
- |
0 |
|
Testing charges included in Cl. 7 |
| Cl.7.3(Marking and Instructions) |
- |
0 |
|
Testing charges included in Cl. 7 |
| Cl.7.4(Marking and Instructions) |
- |
0 |
|
Testing charges included in Cl. 7 |
| Cl.7.5(Marking and Instructions) |
- |
0 |
|
Testing charges included in Cl. 7 |
| Cl.7.6 & IS:302-1:2008(Marking and Instructions) |
- |
0 |
|
Testing charges included in Cl. 7 |
| Cl.7.8 of IS :302-1:2008(Marking and Instructions) |
- |
0 |
|
Testing charges included in Cl. 7 |
| Cl.7.9 of IS :302-1:2008(Marking and Instructions) |
- |
0 |
|
Testing charges included in Cl. 7 |
| Cl.7.10 of IS :302-1:2008(Marking and Instructions) |
- |
0 |
|
Testing charges included in Cl. 7 |
| Cl.7.11 of IS :302-1:2008(Marking and Instructions) |
- |
0 |
|
Testing charges included in Cl. 7 |
| Cl.7.12 & IS:302-1:2008(Marking and Instructions) |
- |
0 |
|
Testing charges included in Cl. 7 |
| Cl.7.12 & IS:302-1:2008(Marking and Instructions) |
- |
0 |
|
Testing charges included in Cl. 7 |
| Cl.7.12 & IS:302-1:2008(Marking and Instructions) |
- |
0 |
|
Testing charges included in Cl. 7 |
| Cl.7.12 & IS:302-1:2008(Marking and Instructions) |
- |
0 |
|
Testing charges included in Cl. 7 |
| Cl.7.12 & IS:302-1:2008(Marking and Instructions) |
- |
0 |
|
Testing charges included in Cl. 7 |
| Cl.7.12 & IS:302-1:2008(Marking and Instructions) |
- |
0 |
|
Testing charges included in Cl. 7 |
| Cl.7.12 & IS:302-1:2008(Marking and Instructions) |
- |
0 |
|
Testing charges included in Cl. 7 |
| Cl.7.12 & IS:302-1:2008(Marking and Instructions) |
- |
0 |
|
Testing charges included in Cl. 7 |
| Cl.7.12 & IS:302-1:2008(Marking and Instructions) |
- |
0 |
|
Testing charges included in Cl. 7 |
| Cl.7.12 & IS:302-1:2008(Marking and Instructions) |
- |
0 |
|
Testing charges included in Cl. 7 |
| Cl.7.12 & IS:302-1:2008(Marking and Instructions) |
- |
0 |
|
Testing charges included in Cl. 7 |
| Cl.7.12 & IS:302-1:2008(Marking and Instructions) |
- |
0 |
|
Testing charges included in Cl. 7 |
| Cl.7.12.1 & IS:302-1:2008(Marking and Instructions) |
- |
0 |
|
Testing charges included in Cl. 7 |
| Cl.7.12.1 & IS:302-1:2008(Marking and Instructions) |
- |
0 |
|
Testing charges included in Cl. 7 |
| Cl.7.12.1 & IS:302-1:2008(Marking and Instructions) |
- |
0 |
|
Testing charges included in Cl. 7 |
| Cl.7.12.1 & IS:302-1:2008(Marking and Instructions) |
- |
0 |
|
Testing charges included in Cl. 7 |
| Cl.7.12.1 & IS:302-1:2008(Marking and Instructions) |
- |
0 |
|
Testing charges included in Cl. 7 |
| Cl.7.12.1 & IS:302-1:2008(Marking and Instructions) |
- |
0 |
|
Testing charges included in Cl. 7 |
| Cl.7.12.1 & IS:302-1:2008(Marking and Instructions) |
- |
0 |
|
Testing charges included in Cl. 7 |
| Cl.7.12.1 & IS:302-1:2008(Marking and Instructions) |
- |
0 |
|
Testing charges included in Cl. 7 |
| Cl.7.12.1 & IS:302-1:2008(Marking and Instructions) |
- |
0 |
|
Testing charges included in Cl. 7 |
| Cl.7.12.1 & IS:302-1:2008(Marking and Instructions) |
- |
0 |
|
Testing charges included in Cl. 7 |
| Cl.7.12.1 & IS:302-1:2009(Marking and Instructions) |
- |
0 |
|
Testing charges included in Cl. 7 |
| Cl.7.13 of IS 302-1:2008(Marking and Instructions) |
- |
0 |
|
Testing charges included in Cl. 7 |
| Cl.7.14 of IS302-1:2008(Marking and Instructions) |
- |
0 |
|
Testing charges included in Cl. 7 |
| Cl.7.14(Marking and Instructions) |
- |
0 |
|
Testing charges included in Cl. 7 |
| Cl.7.14(Marking and Instructions) |
- |
0 |
|
Testing charges included in Cl. 7 |
| Cl.7.15 of IS 302-1:2008(Marking and Instructions) |
- |
0 |
|
Testing charges included in Cl. 7 |
| Cl.7.15 of IS 302-1:2008(Marking and Instructions) |
- |
0 |
|
Testing charges included in Cl. 7 |
| Cl.7.15 of IS 302-1:2008(Marking and Instructions) |
- |
0 |
|
Testing charges included in Cl. 7 |
| Cl.7.15 of IS 302-1:2008(Marking and Instructions) |
- |
0 |
|
Testing charges included in Cl. 7 |
| Cl.7.101(Marking and Instructions) |
- |
0 |
|
Testing charges included in Cl. 7 |
| Cl.8 & IS:302-1:2008(Protection Against Access to Live Parts) |
- |
2000 |
|
- |
| Cl.10 & IS:302-1:2008(Power Input and Current) |
- |
2000 |
|
- |
| Cl.11 & IS:302-1:2008(Heating) |
- |
4000 |
|
- |
| Cl.11 & IS:302-1:2008(Heating) |
- |
0 |
|
Testing charges included in Cl. 11 |
| Cl.11 & IS:302-1:2008(Heating) |
- |
0 |
|
Testing charges included in Cl. 11 |
| Cl.11 & IS:302-1:2008(Heating) |
- |
0 |
|
Testing charges included in Cl. 11 |
| Cl.11 & IS:302-1:2008(Heating) |
- |
0 |
|
Testing charges included in Cl. 11 |
| Cl.11 & IS:302-1:2008(Heating) |
- |
0 |
|
Testing charges included in Cl. 11 |
| Cl.11 & IS:302-1:2008(Heating) |
- |
0 |
|
Testing charges included in Cl. 11 |
| Cl.11 & IS:302-1:2008(Heating) |
- |
0 |
|
Testing charges included in Cl. 11 |
| Cl.11 & IS:302-1:2008(Heating) |
- |
0 |
|
Testing charges included in Cl. 11 |
| Cl.11 & IS:302-1:2008(Heating) |
- |
0 |
|
Testing charges included in Cl. 11 |
| Cl.11 & IS:302-1:2008(Heating) |
- |
0 |
|
Testing charges included in Cl. 11 |
| Cl.11 & IS:302-1:2008(Heating) |
- |
0 |
|
Testing charges included in Cl. 11 |
| Cl.11 & IS:302-1:2008(Heating) |
- |
0 |
|
Testing charges included in Cl. 11 |
| Cl.11 & IS:302-1:2008(Heating) |
- |
0 |
|
Testing charges included in Cl. 11 |
| Cl.11 & IS:302-1:2008(Heating) |
- |
0 |
|
Testing charges included in Cl. 11 |
| Cl.11 & IS:302-1:2008(Heating) |
- |
0 |
|
Testing charges included in Cl. 11 |
| Cl.11.8(Heating) |
- |
0 |
|
Testing charges included in Cl. 11 |
| Cl.11.8(Heating) |
- |
0 |
|
Testing charges included in Cl. 11 |
| Cl.11.8(Heating) |
- |
0 |
|
Testing charges included in Cl. 11 |
| Cl.13 & IS:302-1:2008(Leakage Current & Electric Strength at operating temp. ) |
- |
3000 |
|
- |
| Cl.13 & IS:302-1:2008(Leakage Current & Electric Strength at operating temp. ) |
- |
0 |
|
Testing charges included in Cl. 13 |
| Cl.14 & IS:302-1:2008(Transient Over Voltages) |
- |
2000 |
|
- |
| Cl.15 & IS: 302-1:2008(Moisture Resistance
) |
- |
4000 |
|
- |
| Cl.15.3 of IS 302-1:200(Moisture Resistance
) |
- |
0 |
|
Testing charges included in Cl. 15 |
| Cl.16 & IS:302-1:2008(Leakage Current & Electric Strength ) |
- |
3000 |
|
- |
| Cl.16 & IS:302-1:2008(Leakage Current & Electric Strength ) |
- |
0 |
|
Testing charges included in Cl. 16 |
| Cl.17 & IS:302-1:2008(Over load Protection of Transformers and Associated Circuits ) |
- |
4000 |
|
- |
| Cl.18 (Endurance. ) |
- |
0 |
|
- |
| Cl.19 & IS:302-1:2008(Abnormal Operation.) |
- |
6500 |
|
- |
| Cl.19 & IS:302-1:2008(Abnormal Operation.) |
- |
0 |
|
Testing charges included in Cl. 19 |
| Cl.19 & IS:302-1:2008(Abnormal Operation.) |
- |
0 |
|
Testing charges included in Cl. 19 |
| Cl.19 & IS:302-1:2008(Abnormal Operation.) |
- |
0 |
|
Testing charges included in Cl. 19 |
| Cl.19.101(Abnormal Operation.) |
- |
0 |
|
Testing charges included in Cl. 19 |
| Cl.19.102(Abnormal Operation.) |
- |
0 |
|
Testing charges included in Cl. 19 |
| Cl.19.103(Abnormal Operation.) |
- |
0 |
|
Testing charges included in Cl. 19 |
| Cl.19.104(Abnormal Operation.) |
- |
0 |
|
Testing charges included in Cl. 19 |
| Cl.19.105(Abnormal Operation.) |
- |
0 |
|
Testing charges included in Cl. 19 |
| Cl.19.106(Abnormal Operation.) |
- |
0 |
|
Testing charges included in Cl. 19 |
| Table 8 of IS 302-1:2008(Abnormal Operation.) |
- |
0 |
|
Testing charges included in Cl. 19 |
| Cl.19.107(Abnormal Operation.) |
- |
0 |
|
Testing charges included in Cl. 19 |
| Cl.19.108(Abnormal Operation.) |
- |
0 |
|
Testing charges included in Cl. 19 |
| Cl.19.109(Abnormal Operation.) |
- |
0 |
|
Testing charges included in Cl. 19 |
| Cl.19.110(Abnormal Operation.) |
- |
0 |
|
Testing charges included in Cl. 19 |
| Cl.19.111(Abnormal Operation.) |
- |
0 |
|
Testing charges included in Cl. 19 |
| Cl.19.112(Abnormal Operation.) |
- |
0 |
|
Testing charges included in Cl. 19 |
| Cl.19.113(Abnormal Operation.) |
- |
0 |
|
Testing charges included in Cl. 19 |
| Cl.19.114(Abnormal Operation.) |
- |
0 |
|
Testing charges included in Cl. 19 |
| Cl.20 & IS:302-1:2008(Stability & Mechanical Hazards) |
- |
2000 |
|
- |
| Cl.21 & IS:302-1:2008)(Mechanical Strength.) |
- |
3000 |
|
- |
| Cl.21.2 of IS 302-1:2008(Mechanical Strength.) |
- |
0 |
|
Testing charges included in Cl. 21 |
| Cl.21.101 (Mechanical Strength.) |
- |
0 |
|
Testing charges included in Cl. 21 |
| Cl.21.102(Mechanical Strength.) |
- |
0 |
|
Testing charges included in Cl. 21 |
| Cl.21.103(Mechanical Strength.) |
- |
0 |
|
Testing charges included in Cl. 21 |
| Cl.22.1 of IS 302-1:2008(Construction) |
- |
5000 |
|
- |
| Cl.22.5 of IS 302-1:2008(Construction) |
- |
0 |
|
Testing Testing charges included in Cl. 22.1charges included in Cl. 22.1 |
| Cl.22.6 of IS 302-1:2008(Construction) |
- |
0 |
|
Testing charges included in Cl. 22.1 |
| Cl.22.7 of IS 302-1:2008(Construction) |
- |
0 |
|
Testing charges included in Cl. 22.1 |
| Cl.22.8 of IS 302-1:2008(Construction) |
- |
0 |
|
Testing charges included in Cl. 22.1 |
| Cl.22.9 of IS 302-1:2008(Construction) |
- |
0 |
|
Testing charges included in Cl. 22.1 |
| Cl.22.11(Construction) |
- |
0 |
|
Testing charges included in Cl. 22.1 |
| Cl.22.12 of IS 302-1:2008(Construction) |
- |
0 |
|
Testing charges included in Cl. 22.1 |
| Cl.22.13 of IS 302-1:2008(Construction) |
- |
0 |
|
Testing charges included in Cl. 22.1 |
| Cl.22.14 of IS 302-1:2008(Construction) |
- |
0 |
|
Testing charges included in Cl. 22.1 |
| Cl.22.18 of IS 302-1:2008(Construction) |
- |
0 |
|
Testing charges included in Cl. 22.1 |
| Cl.22.20 of IS 302-1:2008(Construction) |
- |
0 |
|
Testing charges included in Cl. 22.1 |
| Cl.22.21 of IS 302-1:2008(Construction) |
- |
0 |
|
Testing charges included in Cl. 22.1 |
| Cl.23 & IS:302-1:2008(Internal Wiring
) |
- |
2000 |
|
- |
| Cl.23.4 & Cl.29 of 302-1:2008(Internal Wiring
) |
- |
0 |
|
Testing charges included in Cl. 23 |
| Cl.23.5 of 302-1:2008(Internal Wiring
) |
- |
0 |
|
Testing charges included in Cl. 23 |
| Cl.23.7 of 302-1:2008(Internal Wiring
) |
- |
0 |
|
Testing charges included in Cl. 23 |
| C.23.7 of 302-1:2008(Internal Wiring
) |
- |
0 |
|
Testing charges included in Cl. 23 |
| Cl.24.1 of 302-1:2008(Component) |
- |
3000 |
|
- |
| Cl.24.1 of 302-1:2008(Component) |
- |
0 |
|
Testing charges included in Cl. 24.1 |
| Cl.24.1.3 (Component) |
- |
0 |
|
Testing charges included in Cl. 24.1 |
| Cl.24.1.3 (Component) |
- |
0 |
|
Testing charges included in Cl. 24.1 |
| Cl.24.1.3 (Component) |
- |
0 |
|
Testing charges included in Cl. 24.1 |
| Cl.24.1.3 (Component) |
- |
0 |
|
Testing charges included in Cl. 24.1 |
| C.24.1.4(Component) |
- |
0 |
|
Testing charges included in Cl. 24.1 |
| C.24.2 of 302-1:2008(Component) |
- |
0 |
|
Testing charges included in Cl. 24.1 |
| Cl.24.10(Component) |
- |
0 |
|
Testing charges included in Cl. 24.1 |
| Cl.25.1 of 302-1:2008(Supply Connection and External Flexible Cords ) |
- |
2000 |
|
- |
| Cl. 25.2 of IS 3021:2008(Supply Connection and External Flexible Cords ) |
- |
0 |
|
Testing charges included in Cl. 25.1 |
| Cl. 25.3 of IS 302-1:2008(Supply Connection and External Flexible Cords ) |
- |
0 |
|
Testing charges included in Cl. 25.1 |
| Cl. 25.4 of IS 302-1:2008(Supply Connection and External Flexible Cords ) |
- |
0 |
|
Testing charges included in Cl. 25.1 |
| Cl.25.5 of 302-1:2008(Supply Connection and External Flexible Cords ) |
- |
0 |
|
Testing charges included in Cl. 25.1 |
| Cl.25.6 of 302-1:2008(Supply Connection and External Flexible Cords ) |
- |
0 |
|
Testing charges included in Cl. 25.1 |
| Cl.25.7.(Supply Connection and External Flexible Cords ) |
- |
0 |
|
Testing charges included in Cl. 25.1 |
| Cl.25.8(Supply Connection and External Flexible Cords ) |
- |
0 |
|
Testing charges included in Cl. 25.1 |
| Cl. 25.9(Supply Connection and External Flexible Cords ) |
- |
0 |
|
Testing charges included in Cl. 25.1 |
| Cl.25.10 of 302-1:2008(Supply Connection and External Flexible Cords ) |
- |
0 |
|
Testing charges included in Cl. 25.1 |
| Cl. 25.11(Supply Connection and External Flexible Cords ) |
- |
0 |
|
Testing charges included in Cl. 25.1 |
| Cl. 25.12(Supply Connection and External Flexible Cords ) |
- |
0 |
|
Testing charges included in Cl. 25.1 |
| Cl. 25.13(Supply Connection and External Flexible Cords ) |
- |
0 |
|
Testing charges included in Cl. 25.1 |
| Cl.25.14 of IS 302-1:2008(Supply Connection and External Flexible Cords ) |
- |
0 |
|
Testing charges included in Cl. 25.1 |
| Cl.25.15 of IS 302-1:2008(Supply Connection and External Flexible Cords ) |
- |
0 |
|
Testing charges included in Cl. 25.1 |
| Cl.25.15 of IS 302-1:2008(Supply Connection and External Flexible Cords ) |
- |
0 |
|
Testing charges included in Cl. 25.1 |
| Cl.25.17 of IS 302-1:2008(Supply Connection and External Flexible Cords ) |
- |
0 |
|
Testing charges included in Cl. 25.1 |
| Cl.25.18(Supply Connection and External Flexible Cords ) |
- |
0 |
|
Testing charges included in Cl. 25.1 |
| Cl.25.20(Supply Connection and External Flexible Cords ) |
- |
0 |
|
Testing charges included in Cl. 25.1 |
| Cl.26.1 of IS 302-1:2008(Terminal for External Conductors
) |
- |
1000 |
|
- |
| Cl.26.10 of IS 302-1:2008(Terminal for External Conductors
) |
- |
0 |
|
Testing charges included in Cl. 26.1 |
| Cl.26.11 of IS 302-1:2008(Terminal for External Conductors
) |
- |
0 |
|
Testing charges included in Cl. 26.1 |
| Cl.27.1 of 302-1:2008(Provision for Earthing.) |
- |
2000 |
|
- |
| Cl.27.5 of 302-1:2008(Provision for Earthing.) |
- |
0 |
|
Testing charges included in Cl. 27.1 |
| Cl.28 of 302-1:2008(Screws and Connections.) |
- |
1000 |
|
- |
| Cl.29 & IS:302-1:2008(Clearances, Creepage Distances and Solid Insulation) |
- |
2000 |
|
- |
| Cl.29 & IS:302-1:2008(Clearances, Creepage Distances and Solid Insulation) |
- |
0 |
|
Testing charges included in Cl. 29 |
| Cl.30 & IS:302-1:2008(Resistance to Heat and Fire) |
- |
3000 |
|
- |
| Cl.30.2.2 of 302-1:2008(Resistance to Heat and Fire) |
- |
0 |
|
Testing charges included in Cl. 30 |
| Cl.31 & IS:302-1:2008(Resistance to Rusting.) |
- |
0 |
|
- |
| Cl.32 & IS:302-1:2008(Radition,Toxicity and similar Hazards.) |
- |
0 |
|
- |
| Cl.31 of IS:302-1:2008(Resistance to Rusting.) |
- |
0 |
|
- |
| Cl.30.2 of 302-1:2008(Resistance to Heat and Fire : Resistance to fire) |
- |
0 |
|
Testing charges included in Cl. 30 |
| Cl.30.1 of IS:302-1:2008(Resistance to Heat and Fire: Resistance to heat. ) |
- |
0 |
|
Testing charges included in Cl. 30 |
| Cl.29.2 of IS:302-1:2008(Clearances, Creepage Distances and Solid Insulation : Creepage Distance) |
- |
0 |
|
Testing charges included in Cl. 29 |
| Cl.29.1 of IS:302-1:2008(Clearances, Creepage Distances and Solid Insulation : Clearance ) |
- |
0 |
|
Testing charges included in Cl. 29 |
| Cl.28 of 302-1:2008(Screws and Connections.) |
- |
0 |
|
Testing charges included in Cl. 28 |
| Cl.27.5 of 302-1:2008(Provision for Earthing : ECR) |
- |
0 |
|
Testing charges included in Cl. 27.1 |
| Cl.27.1 of 302-1:2008(Provision for Earthing ) |
- |
0 |
|
Testing charges included in Cl. 27.1 |
| Cl.26 of IS 302-1:2008(Terminal for External Conductors
) |
- |
0 |
|
Testing charges included in Cl. 26 |
| Cl.25.20 of 302-1:2008(Supply Connection and External Flexible Cords : Additional insulation ) |
- |
0 |
|
Testing charges included in Cl. 25.1 |
| Cl.25.18 of 302-1:2008(Supply Connection and External Flexible Cords : Arrangement of cord anchorages ) |
- |
0 |
|
Testing charges included in Cl. 25.1 |
| Cl.25.15 of IS 302-1:2008(Supply Connection and External Flexible Cords : Cord grip test - displacement) |
- |
0 |
|
Testing charges included in Cl. 25.1 |
| Cl.25.15 of IS 302-1:2008(Supply Connection and External Flexible Cords : Cord grip test - strain at terminals ) |
- |
0 |
|
Testing charges included in Cl. 25.1 |
| Cl. 25.13 of 302-1:2008(Supply Connection and External Flexible Cords : Inlet opening of supply cords ) |
- |
0 |
|
Testing charges included in Cl. 25.1 |
| Cl. 25.12 of 302-1:2008(Supply Connection and External Flexible Cords : Moulding of cords ) |
- |
0 |
|
Testing charges included in Cl. 25.1 |
| Cl.25.10 of 302-1:2008(Supply Connection and External Flexible Cords : Colour of earthing wire ) |
- |
0 |
|
Testing charges included in Cl. 25.1 |
| Cl. 25.9 of 302-1:2008(Supply Connection and External Flexible Cords : Contact with sharp edge ) |
- |
0 |
|
Testing charges included in Cl. 25.1 |
| Cl.25.8 of 302-1:2008(Supply Connection and External Flexible Cords : Resistance of supply wires ) |
- |
0 |
|
Testing charges included in Cl. 25.1 |
| Cl.25.7 of IS:302-2-30:2007(Supply Connection and External Flexible Cords : Supply cords material ) |
- |
0 |
|
Testing charges included in Cl. 25.1 |
| Cl.25.5 of 302-1:2008(Supply Connection and External Flexible Cords : Type of attachments ) |
- |
0 |
|
Testing charges included in Cl. 25.1 |
| Cl.25.1 of 302-1:2008(Supply Connection and External Flexible Cords : Means of connection ) |
- |
0 |
|
Testing charges included in Cl. 25.1 |
| Cl.24 of IS:302-2-30:2007(Component) |
- |
0 |
|
Testing charges included in Cl. 24 |
| Cl.23.7 of 302-1:2008(Internal Wiring : Colour of earting conductor
) |
- |
0 |
|
Testing charges included in Cl. 23 |
| Cl.23 of IS:302-1:2008(Internal Wiring
) |
- |
0 |
|
Testing charges included in Cl. 23 |
| Cl.22.106 of IS:302-2-30:2007(Construction : Checking of thermostats, timers or similar means for visibl glowing radiant heaters) |
- |
0 |
|
Testing charges included in Cl. 22.1 |
| Cl.22.106 of IS:302-2-30:2007(Construction : Checking of openings on the underside) |
- |
0 |
|
Testing charges included in Cl. 22.1 |
| Cl.22.102 & Cl 22.103 of IS:302-2-30:2007(Construction : Fireguard ) |
- |
0 |
|
Testing charges included in Cl. 22.1 |
| Cl.22.101 of IS:302-2-30:2007(Construction : Prevention to contact with heating element) |
- |
0 |
|
Testing charges included in Cl. 22.1 |
| Cl.22.24 of IS:302-2-30:2007(Construction : test of bare heating element) |
- |
0 |
|
Testing charges included in Cl. 22.1 |
| Cl.22.18 of IS 302-1:2008(Construction : Resistance to corrosion ) |
- |
0 |
|
Testing charges included in Cl. 22.1 |
| Cl.22.15 of IS 302-1:2008(Construction : Storage hooks for flexible cords) |
- |
0 |
|
Testing charges included in Cl. 22.1 |
| Cl.22.14 of IS 302-1:2008(Construction : ragged and sharp edges) |
- |
0 |
|
Testing charges included in Cl. 22.1 |
| Cl.22.13 of IS 302-1:2008(Construction : Position of handles ) |
- |
0 |
|
Testing charges included in Cl. 22.1 |
| Cl.22.12 of IS 302-1:2008(Construction : Fixing of Handle, knobs,grips,lever and similer parts ) |
- |
0 |
|
Testing charges included in Cl. 22.1 |
| Cl.22.11 of IS 302-1:2008(Construction : Fixing of non detachable parts ) |
- |
0 |
|
Testing charges included in Cl. 22.1 |
| Cl.22.7 of IS:302-2-30:2007(Construction : Pressure test of oil heater ) |
- |
0 |
|
Testing charges included in Cl. 22.1 |
| Cl.21.101 of IS:302-2-30:2007(Mechanical Strength : fire gaurd deformation test ) |
- |
0 |
|
Testing charges included in Cl. 21 |
| Cl.21.2 of IS 302-1:2008(Mechanical Strength : Pentration by sharp implementation ) |
- |
0 |
|
Testing charges included in Cl. 21 |
| Cl.21.1 of IS:302-1:2008)(Mechanical Strength : Rough handling ) |
- |
0 |
|
Testing charges included in Cl. 21 |
| Cl.20 of IS:302-2-30:2007(Stability of Mechanical Hazards) |
- |
0 |
|
Testing charges included in Cl. 20 |
| Cl.19.114 of IS:302-2-30:2007(Abnormal Operation : the temp. of the surface of the container for oil heaters ) |
- |
0 |
|
Testing charges included in Cl. 19 |
| Cl.19.112 of IS:302-2-30:2007(Abnormal Operation : Ignition of bleached cotton gauge) |
- |
0 |
|
Testing charges included in Cl. 19 |
| Cl.19.111 of IS:302-2-30:2007(Abnormal Operation : Ignition of flannelette for Visibly glowing heaters) |
- |
0 |
|
Testing charges included in Cl. 19 |
| Cl.19.110 of IS:302-2-30:2007(Abnormal Operation : operation against wall for visibly glowing radiant heaters ) |
- |
0 |
|
Testing charges included in Cl. 19 |
| Cl.19.109 of IS:302-2-30:2007(Abnormal Operation : operation against wall for fan heater ) |
- |
0 |
|
Testing charges included in Cl. 19 |
| Cl.19.106 of IS:302-2-30:2007(Abnormal Operation : Locked rotor of fan hetear ) |
- |
0 |
|
Testing charges included in Cl. 19 |
| Cl.19.103 , Cl 19.104 of IS:302-2-30:2007(Abnormal Operation : Operation after Covering by cotton) |
- |
0 |
|
Testing charges included in Cl. 19 |
| Cl.19 of IS:302-2-30:2007(Abnormal Operation : High Voltage ) |
- |
0 |
|
Testing charges included in Cl. 19 |
| Cl.19 of IS:302-2-30:2007(Abnormal Operation : temp rise of supply cord ) |
- |
0 |
|
Testing charges included in Cl. 19 |
| Cl.19 of IS:302-2-30:2007(Abnormal Operation : Temp rise of test corner ) |
- |
0 |
|
Testing charges included in Cl. 19 |
| Cl.19 of IS:302-1:2008(Abnormal Operation : Emission of molten or poisonous or ignitable gas) |
- |
0 |
|
Testing charges included in Cl. 19 |
| Cl.16 of IS:302-1:2008(Leakage current and Electric strength (After humidity): Electric Strentgh ) |
- |
0 |
|
Testing charges included in Cl. 16 |
| Cl.16 of IS:302-1:2008(Leakage current and Electric strength (After humidity): Leakage current ) |
- |
0 |
|
Testing charges included in Cl. 16 |
| Cl.15 of IS 302-1:2008(Moisture Resistance
) |
- |
0 |
|
Testing charges included in Cl. 15 |
| Cl.14 of IS:302-1:2008(Transient Over Voltages) |
- |
0 |
|
Testing charges included in Cl. 14 |
| Cl.13 of IS:302-1:2008(Leakage Current of Electric Strength at operating temp. ) |
- |
0 |
|
Testing charges included in Cl. 13 |
| Cl.13 of IS:302-1:2008(Leakage Current of Electric Strength at operating temp. ) |
- |
0 |
|
Testing charges included in Cl. 13 |
| Cl.11 of IS:302-2:30: 2007(Heating : Room temperature) |
- |
0 |
|
Testing charges included in Cl. 11 |
| Cl.11.8 of IS:302-2:30: 2007(Heating : For liquid filled radiators the temp. rise of the outer surface of the liquid container) |
- |
0 |
|
Testing charges included in Cl. 11 |
| Cl.11 of IS:302-2:30: 2007(Heating : Temperature rise in winding) |
- |
0 |
|
Testing charges included in Cl. 11 |
| Cl.11 of IS:302-2:30: 2007(Heating : Air-outlet grills) |
- |
0 |
|
Testing charges included in Cl. 11 |
| Cl.11 of IS:302-2:30: 2007(Heating : Surfaces of handles, knobs, grips and similar parts) |
- |
0 |
|
Testing charges included in Cl. 11 |
| Cl.11 of IS:302-2:30: 2007(Heating : Wooden supports, walls, ceiling and floor of the test corner) |
- |
0 |
|
Testing charges included in Cl. 11 |
| Cl.11 of IS:302-2:30: 2007(Heating : PVC Insulation ) |
- |
0 |
|
Testing charges included in Cl. 11 |
| Cl.10 of IS:302-1:2008(Power Input and Current) |
- |
0 |
|
Testing charges included in Cl. 10 |
| Cl.8 of IS:302-1:2008(Protection Against Access to Live Parts) |
- |
0 |
|
Testing charges included in Cl. 8 |
| Cl.7.101 of IS:302-2:30: 2007(Marking and Instructions : standard mark. ) |
- |
0 |
|
Testing charges included in Cl. 7 |
| Cl.7.15 of IS 302-1:2008(Marking and Instructions : Visibility of marking concerning covering) |
- |
0 |
|
Testing charges included in Cl. 7 |
| Cl.7.15 of IS 302-1:2008(Marking and Instructions : discernibility from the out side ) |
- |
0 |
|
Testing charges included in Cl. 7 |
| Cl.7.14 of IS:302-2:30: 2007(Marking and Instructions : Height of “Do not cover”) |
- |
0 |
|
Testing charges included in Cl. 7 |
| Cl.7.14 of IS:302-2:30: 2007(Marking and Instructions : height of symbol) |
- |
0 |
|
Testing charges included in Cl. 7 |
| Cl.7.14 of IS302-1:2008(Marking and Instructions : Legibility and durability ) |
- |
0 |
|
Testing charges included in Cl. 7 |
| Cl.7.13 of IS 302-1:2008(Marking and Instructions : Languge of instruction and texts ) |
- |
0 |
|
Testing charges included in Cl. 7 |
| Cl.7.11 of IS :302-1:2008(Marking and Instructions : Controls ) |
- |
0 |
|
Testing charges included in Cl. 7 |
| Cl.7.9 of IS :302-1:2008(Marking and Instructions : switches ) |
- |
0 |
|
Testing charges included in Cl. 7 |
| Cl.7.8 of IS :302-1:2008(Marking and Instructions : terminals ) |
- |
0 |
|
Testing charges included in Cl. 7 |
| Cl.7.6 of IS:302-1:2008(Marking and Instructions : Symbols ) |
- |
0 |
|
Testing charges included in Cl. 7 |
| Cl.7.5 of IS:302-1:2008(Marking and Instructions : upper of lower limit of the rated power input ) |
- |
0 |
|
Testing charges included in Cl. 7 |
| Cl 7.1 & Cl.7.6 of IS:302-2:30: 2007(Marking and Instructions : Do not cover ) |
- |
0 |
|
Testing charges included in Cl. 7 |
| Cl.7.1 of IS:302-1:2008(Marking and Instructions : Country of manufacture ) |
- |
0 |
|
Testing charges included in Cl. 7 |
| Cl.7.1 of IS:302-1:2008(Marking and Instructions : Symbol for Class-II ) |
- |
0 |
|
Testing charges included in Cl. 7 |
| Cl.7.1 of IS:302-1:2008(Marking and Instructions : Model or type ) |
- |
0 |
|
Testing charges included in Cl. 7 |
| Cl.7.1 of IS:302-1:2008(Marking and Instructions : Name , trade-mark or identification mark of the manufacturer ) |
- |
0 |
|
Testing charges included in Cl. 7 |
| Cl.7.1 of IS:302-1:2008(Marking and Instructions : rated power input ) |
- |
0 |
|
Testing charges included in Cl. 7 |
| Cl.7.1 of IS:302-1:2008(Marking and Instructions : Nature of supply ) |
- |
0 |
|
Testing charges included in Cl. 7 |
| Cl.7.1 of IS:302-1:2008(Marking and Instructions : Rated Voltage ) |
- |
0 |
|
Testing charges included in Cl. 7 |
| Cl.22.15 of IS 302-1:2008(Construction) |
- |
0 |
|
Testing charges included in Cl. 7 |
|
- |
- Included w.e.f.20.06.2025
Exclusion
(EMI/EMC)Cl 19.11.4.1 TO Cl 19.11.4.7 |
| 5353 |
ADS LABTECH, GHAZIABAD
| 8178326
| IS 14255 (1995) |
Aertal bunched cables - For working voltages up to and including 1100 Volts - Specification |
1100V |
10500 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4.1(Phase/Street Lighting conductor) |
- |
100 |
|
- |
| 4.2(Messenger (Neutral Conductor or Otherwise)) |
- |
100 |
|
- |
| 5.1(Insulation) |
- |
100 |
|
100 |
| 6.1(Flexibility class) |
- |
100 |
|
- |
| 6.2(Compactness) |
- |
100 |
|
- |
| 6.2(No of strands) |
- |
100 |
|
- |
| 6.2(Surface) |
- |
100 |
|
- |
| 6.3(Protective barrier) |
- |
100 |
|
- |
| 6.4(size of street lighting conductor) |
- |
100 |
|
- |
| 6.5(Size of messenger conductor ) |
- |
100 |
|
- |
| 6.6(Joints in messenger conductor ) |
- |
100 |
|
- |
| 6.6(Direction of outer layer) |
- |
100 |
|
- |
| 7.1(Insulation) |
- |
100 |
|
- |
| 7.2( Thickness of insulation) |
- |
200 |
|
- |
| 7.3(Tolerance on thickness of insulation ) |
- |
200 |
|
- |
| 7.4(Aplication of the insulation ) |
- |
100 |
|
- |
| 7.5(Colour of the insulation ) |
- |
100 |
|
- |
| 8.1(Core identification) |
- |
100 |
|
- |
| 8.2(Core identification) |
- |
100 |
|
- |
| 8.3(Identification by other means) |
- |
100 |
|
- |
| 9.1(Assembly (Laying up)) |
- |
100 |
|
- |
| 9.2(Assembly (Laying up)) |
- |
100 |
|
- |
| 9.3(Direction of lay) |
- |
200 |
|
- |
| 10.1 a) i)(Tests on phase/street light conductor: tensile test - Test method IS10810:Part 2) |
- |
500 |
|
- |
| 10.1 a) ii)(Wrapping test - 10810: Part 3) |
- |
500 |
|
- |
| 10.1 a) iii)(Resistance test - IS10810: Part 5) |
- |
700 |
|
- |
| 10.1 b) i)(Test on messenger conductor: Breaking load - IS 10810: Part 2) |
- |
500 |
|
- |
| 10.1 b) ii)(Test on messenger conductor: Elongation test - Cl 11.3) |
- |
500 |
|
- |
| 10.1 b) iii)(Test on messenger conductor: Resistance test - IS 10810: Part 5) |
- |
500 |
|
- |
| 10.1 c) i)(Physical tests for XLPE Insulation:
Tensile strength - IS 10810: Part 7) |
- |
200 |
|
- |
| 10.1 c) i)(Physical tests for XLPE Insulation:
elongation at break - IS 10810: part 7) |
- |
200 |
|
- |
| 10.1 c) ii)(Ageing in air oven : Tensile strength variation - IS 10810:Part 11) |
- |
200 |
|
- |
| 10.1 c) ii)(Ageing in air oven : Elongation variation- IS 10810: Part 11) |
- |
200 |
|
- |
| 10.1 c) iii)(Hot set test: Elongation under load - IS 10810: Part 30) |
- |
200 |
|
- |
| 10.1 c) iii)(Hot set test: Permanent elongation (set) after cooling - IS 10810: Part 30) |
- |
200 |
|
- |
| 10.1 c) iv)(Shrinkage test : Shrinkage - 10810:Part 12) |
- |
200 |
|
- |
| 10.1 c) iv)(Shrinkage test : Crack Observed - 10810:Part 12) |
- |
200 |
|
- |
| 10.1 c) v)(Water ahsorption (Gravimetric) - IS 10810: Part 33 ) |
- |
500 |
|
- |
| 10.1 d) i)(Physical test for PE insulation:
Tensile strength - IS 10810: Part 7 ) |
- |
500 |
|
- |
| 10.1 d) i)(Physical test for PE insulation: elongation at break - IS 10810: Part 7) |
- |
500 |
|
- |
| 10.1 d) ii)(Melt flow index- IS 10810: Part 23) |
- |
500 |
|
- |
| 10.1 d) iv)(Vicat softening point -IS 10810: Part 22) |
- |
500 |
|
- |
| 10.1 d) v)(Environmental stress cracking -IS 10810:Part29) |
- |
500 |
|
- |
| 10.1 f)(Insulation resistance (Volume resistivity) test a) volume resistivity at 27°C - IS 10810: Part 43) |
- |
500 |
|
- |
| 10.1 f)(Insulation resistance (Volume resistivity) test b) volume resistivity at 70°C - IS 10810: Part 43) |
- |
500 |
|
- |
| 10.1 g)(High voltage test - IS10810:Part 45) |
- |
500 |
|
- |
| 11.4(Bending Test on the Completed Cable ( Optional) ) |
- |
500 |
|
- |
| 11.4(Bending Test on the Completed Cable ( Optional)) |
- |
500 |
|
- |
| 10.1 d) iii)(Carbon Black Content) |
- |
500 |
|
- |
| 6.1(Construction of phase conductor) |
- |
100 |
|
- |
| 6.1(Number of wires (phase conductor)) |
- |
100 |
|
- |
| 6.1(Construction of Street Lighting conductor) |
- |
100 |
|
- |
| 6.1(Number of wires (Street Lighting conductor)) |
- |
100 |
|
- |
| 12.1(Manufacturer's Identification) |
- |
100 |
|
- |
| 12.2(Cable Identification) |
- |
100 |
|
- |
|
15 May, 2027 |
- Included w.e.f 13.05.2025 |
| 5354 |
REACT COMPLIANCE AND TESTING LABORATORIES LLP, BENGALURU
| 6130526
| IS 16270 (2023) |
Secondary cells and batteries for solar photovoltaic application - General requirements and methods of test |
- |
684000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl-4.1(Photovoltaic Energy System) |
- |
2000 |
|
- |
| Cl-4.2(Secondary Cells and Batteries) |
- |
2000 |
|
- |
| Cl-4.3(General Operating Conditions) |
- |
2000 |
|
- |
| Cl-4.3.8(Storage) |
- |
2000 |
|
- |
| Cl-4.3.9(Operating Temperature) |
- |
2000 |
|
- |
| Cl-5.1(Mechanical Endurance) |
- |
5000 |
|
- |
| Cl-5.2(Charge Efficiency) |
- |
10000 |
|
- |
| Cl-5.3(Deep Discharge Protection) |
- |
10000 |
|
- |
| Cl-5.4(Marking) |
- |
2000 |
|
- |
| Cl-5.5(Safety) |
- |
5000 |
|
- |
| Cl-6(Functional characteristice) |
- |
1000 |
|
- |
| Cl-7(General test conditions) |
- |
1000 |
|
- |
| Cl-8.1(Capacity Test) |
- |
20000 |
|
- |
| Cl-8.2(Endurance Test) |
- |
300000 |
|
- |
| Cl-8.3(Charge Retention Test) |
- |
100000 |
|
- |
| Cl-8.4(Cycle Endurance in Photovoltaic Application (Extreme Conditions)) |
- |
200000 |
|
- |
| Cl-8.5(Sulphation Test (Applicable for Lead Acid Batteries only)) |
- |
10000 |
|
- |
| Cl-8.6(Water Loss Test (Valid for Flooded Lead Acid Batteries only)) |
- |
10000 |
|
- |
| Cl-9.1(Type Tests) |
- |
0 |
|
- |
| Cl-9.2(Acceptance Test) |
- |
0 |
|
- |
| 4.3.7.1(Specific gravity) |
- |
0 |
|
- |
| Cl-5.6(Documentation) |
- |
0 |
|
- |
| Cl-4.1(Photovoltaic Energy System) |
- |
2000 |
|
- |
| Cl-4.2(Secondary Cells and Batteries) |
- |
2000 |
|
- |
| Cl-4.3(General Operating Conditions) |
- |
2000 |
|
- |
| Cl-4.3.8(Storage) |
- |
2000 |
|
- |
| Cl-4.3.9(Operating Temperature) |
- |
2000 |
|
- |
| Cl-5.1(Mechanical Endurance) |
- |
5000 |
|
- |
| Cl-5.2(Charge Efficiency) |
- |
10000 |
|
- |
| Cl-5.3(Deep Discharge Protection) |
- |
10000 |
|
- |
| Cl-5.4(Marking) |
- |
2000 |
|
- |
| Cl-5.5(Safety) |
- |
5000 |
|
- |
| Cl-6(Functional characteristice) |
- |
1000 |
|
- |
| Cl-7(General test conditions) |
- |
1000 |
|
- |
| Cl-8.1(Capacity Test) |
- |
20000 |
|
- |
| Cl-8.2(Endurance Test) |
- |
300000 |
|
- |
| Cl-8.3(Charge Retention Test) |
- |
100000 |
|
- |
| Cl-8.4(Cycle Endurance in Photovoltaic Application (Extreme Conditions)) |
- |
200000 |
|
- |
| Cl-8.5(Sulphation Test (Applicable for Lead Acid Batteries only)) |
- |
10000 |
|
- |
| Cl-8.6(Water Loss Test (Valid for Flooded Lead Acid Batteries only)) |
- |
10000 |
|
- |
| Cl-9.1(Type Tests) |
- |
0 |
|
- |
| Cl-9.2(Acceptance Test) |
- |
0 |
|
- |
| 4.3.7.1(Specific gravity) |
- |
10000 |
|
- |
| Cl-5.6(Documentation) |
- |
1000 |
|
- |
| Cl-4.1(Photovoltaic Energy System) |
- |
0 |
|
- |
| Cl-4.2(Secondary Cells and Batteries) |
- |
0 |
|
- |
| Cl-4.3(General Operating Conditions) |
- |
0 |
|
- |
| Cl-4.3.8(Storage) |
- |
0 |
|
- |
| Cl-4.3.9(Operating Temperature) |
- |
0 |
|
- |
| Cl-5.1(Mechanical Endurance) |
- |
684000 |
|
- |
| Cl-5.2(Charge Efficiency) |
- |
0 |
|
- |
| Cl-5.3(Deep Discharge Protection) |
- |
0 |
|
- |
| Cl-5.4(Marking) |
- |
0 |
|
- |
| Cl-5.5(Safety) |
- |
0 |
|
- |
| Cl-6(Functional characteristice) |
- |
0 |
|
- |
| Cl-7(General test conditions) |
- |
0 |
|
- |
| Cl-8.1(Capacity Test) |
- |
0 |
|
- |
| Cl-8.2(Endurance Test) |
- |
0 |
|
- |
| Cl-8.3(Charge Retention Test) |
- |
0 |
|
- |
| Cl-8.4(Cycle Endurance in Photovoltaic Application (Extreme Conditions)) |
- |
0 |
|
- |
| Cl-8.5(Sulphation Test (Applicable for Lead Acid Batteries only)) |
- |
0 |
|
- |
| Cl-8.6(Water Loss Test (Valid for Flooded Lead Acid Batteries only)) |
- |
0 |
|
- |
| Cl-9.1(Type Tests) |
- |
0 |
|
- |
| Cl-9.2(Acceptance Test) |
- |
0 |
|
- |
| 4.3.7.1(Specific gravity) |
- |
0 |
|
- |
| Cl-5.6(Documentation) |
- |
0 |
|
- |
|
10 Mar, 2027 |
- Included w.e.f 04.07.2025 |
| 5355 |
Classic Testing & Research Centre (B17), Noida
| 8180826
| IS 302 : Part 2 : Sec 209 (1994) |
Safety of household and similar electrical appliances: Part 2 particular requirements: Sec 209 low speed food grinding machines |
- |
40000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl. 32 302-2-209 : 1994(Radiation Hazards) |
- |
5000 |
|
- |
| Cl. 31 302-2-209 : 1994(Resistance to Rusting) |
- |
5000 |
|
- |
| Cl. 30 302-2-209 : 1994(Resistance to Heat Fire & Tracking ) |
- |
5000 |
|
- |
| Cl. 29 302-2-209 : 1994(Clearances, Creepage Distances & Solid insulation ) |
- |
5000 |
|
- |
| Cl. 28 302-2-209 : 1994(Screws & Connections) |
- |
5000 |
|
- |
| Cl. 27 302-2-209 : 1994(Provision for Earthing ) |
- |
5000 |
|
- |
| Cl. 26 302-2-209 : 1994(Terminals for External conductors ) |
- |
5000 |
|
- |
| Cl. 25 302-2-209 : 1994(Supply Connection & External Flexible Cords) |
- |
5000 |
|
- |
| Cl. 24 302-2-209 : 1994(Components) |
- |
5000 |
|
- |
| Cl. 23 302-2-209 : 1994(Internal Wiring) |
- |
5000 |
|
- |
| Cl. 22 302-2-209 : 1994(Construction ) |
- |
5000 |
|
- |
| Cl. 21 302-2-209 : 1994(Mechanical strength) |
- |
5000 |
|
- |
| Cl. 20 302-2-209 : 1994(Stability & Mechanical Hazards) |
- |
5000 |
|
- |
| Cl. 19 302-2-209 : 1994(Abnormal Operation ) |
- |
5000 |
|
- |
| Cl. 18 302-2-209 : 1994(Endurance) |
- |
5000 |
|
- |
| Cl. 17 302-2-209 : 1994(Overload Protection of Transformers and Associated Circuit) |
- |
5000 |
|
- |
| Cl. 16 302-2-209 : 1994(Leakage Current & Electric Strength at Operating Temperature (After Humidity Treatment)) |
- |
5000 |
|
- |
| Cl. 15 302-2-209 : 1994(Moisture Resistance Test ) |
- |
5000 |
|
- |
| Cl. 14 302-2-209 : 1994(Radio and television interference suppression / Transient over voltages) |
- |
5000 |
|
- |
| Cl. 13 302-2-209 : 1994(Leakage Current & Electric Strength at Operating Temperature) |
- |
5000 |
|
- |
| Cl. 11 302-2-209 : 1994(Temperature Rise) |
- |
5000 |
|
- |
| Cl. 10 302-2-209 : 1994(Power Input and Current ) |
- |
5000 |
|
- |
| Cl. 9 302-2-209 : 1994(Starting of motor operated appliances) |
- |
5000 |
|
- |
| Cl. 8 302-2-209 : 1994(Protection Against Electric Shock ) |
- |
5000 |
|
- |
| Cl. 7 302-2-209 : 1994(Marking) |
- |
5000 |
|
- |
| (CI. 6 IS 302-2-209 : 1994(Classification ) |
- |
5000 |
|
- |
| Cl. 5 IS 302-2-209 :1994(Rating) |
- |
5000 |
|
- |
| Cl-19.11.4.1(Electrostatic discharge) |
- |
5000 |
|
- |
| Cl-19.11.4.3(Fast transient bursts) |
- |
5000 |
|
- |
| Cl-19.11.4.4(Surge Immunity test) |
- |
5000 |
|
- |
| Cl-19.11.4.6(Voltage dips and interruptions) |
- |
5000 |
|
- |
| Cl-19.11.4.7(Harmonics) |
- |
5000 |
|
- |
|
15 Oct, 2027 |
- Included w.e.f.13.05.2025
Exclusion
Cl-19.11.4.2 (Radiated Fields)
Cl-19.11.4.5 (Immunity to conducted discharge) |
| 5356 |
Anacon Laboratories Pvt. Ltd, Nagpur
| 7124116
| IS 15609 (2005) |
Polyethylene flexible pouches for the packing of natural mineral water and packaged drinking water - Specification |
- |
10800.00 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 6.1.1(Description) |
- |
200.00 |
|
- |
| 6.1.2(Film Form) |
- |
200.00 |
|
- |
| 6.1.3(Winding of the Film ) |
- |
200.00 |
|
- |
| 6.1.4(Odour) |
- |
100.00 |
|
- |
| 6.1.5 A-2 of IS: 2508:2016(Thickness) |
- |
200.00 |
|
- |
| 6.1.6(Width) |
- |
200.00 |
|
- |
| 6.1.7 IS: 9845:1998(Migration- a. Amount of extractive ) |
- |
900.00 |
|
- |
| 6.1.8 Annex 4 of IS:2508:2016(Tensile Strength a. Lengthwise direction) |
- |
150.00 |
|
Cost of Tensile Strength- 300.00 |
| 6.1.8 Annex 4 of IS:2508:2016(Tensile Strength b. Crosswise direction) |
- |
150.00 |
|
Cost of Tensile Strength- 300.00 |
| 6.1.9 Annex 4 of IS:2508:2016(Elongation at break - a. Lengthwise direction) |
- |
100.00 |
|
Cost of Elongation at break- 200.00 |
| 6.1.9 Annex 4 of IS:2508:2016(Elongation at break - b. Crosswise direction) |
- |
100.00 |
|
Cost of Elongation at break- 200.00 |
| 6.1.10 Annex -6 of IS:2508:2016(Dart impact Resistance) |
- |
200.00 |
|
- |
| 7.1 Annex E(Water Potability test (after 30 Days) a) Taste b) Odour) |
- |
900.00 |
|
- |
| 7.2 Annex F(Stack Load test) |
- |
300.00 |
|
- |
| 7.3 Annex G(Drop test ) |
- |
300.00 |
|
- |
| 7.4 Annex H(Ink adhesion test for printed pouches) |
- |
300.00 |
|
- |
| 7.5 Annex J(Product resistance test for printed pouches) |
- |
300.00 |
|
- |
| 5(Material) |
- |
1200.00 |
|
- |
| CL 6.1.11.2 and 6.1.11.3, Table 3 (ix)(Phthalic acid, bis(2-ethylhexyl) ester (DEHP)) |
- |
4800 |
|
For metals and Phthalic acid |
| CL 6.1.11.2 and 6.1.11.3, Table 3 (ix)(Phthalic acid, bis(2-ethylhexyl) ester (DEHP)) |
- |
4800 |
|
For metals and Phthalic acid |
| CL 6.1.11.2 and 6.1.11.3, Table 3 (i)(Barium) |
- |
4800.00 |
|
For metals and Phthalic acid |
| Table 3(ix) Phthalic acid, bis(2-ethylhexyl)ester (DEHP)) |
- |
4800.00 |
|
For metals and Phthalic acid |
| CL 6.1.11.2 and 6.1.11.3, Table 3 (ii)(Cobalt) |
- |
4800.00 |
|
For metals and Phthalic acid |
| CL 6.1.11.2 and 6.1.11.3, Table 3 (iii)(Copper) |
- |
4800.00 |
|
For metals and Phthalic acid |
| CL 6.1.11.2 and 6.1.11.3, Table 3 (iv)(Iron) |
- |
4800.00 |
|
For metals and Phthalic acid |
| CL 6.1.11.2 and 6.1.11.3, Table 3 (v)(Lithium) |
- |
4800.00 |
|
For metals and Phthalic acid |
| CL 6.1.11.2 and 6.1.11.3, Table 3 (vi)(Manganese) |
- |
4800.00 |
|
For metals and Phthalic acid |
| CL 6.1.11.2 and 6.1.11.3, Table 3 (vii)(Zinc) |
- |
4800.00 |
|
For metals and Phthalic acid |
| Table 3(viii) Antimony) |
- |
4800.00 |
|
For metals and Phthalic acid |
|
- |
- - |
| 5357 |
Anacon Laboratories Pvt. Ltd, Nagpur
| 7124116
| IS 15410 (2003) |
Containers for packaging of natural mineral water and packaged drinking water - Specification |
- |
10800 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4.1(Material) |
- |
1200.00 |
|
ok |
| 4.6.3, clause 6 of IS:2798:1998(Leakage test- c. Air pressure leakage) |
- |
300.00 |
|
- |
| 4.6.3, clause 6 of IS:2798:1998(Leakage test- b. Vibration leakage) |
- |
300.00 |
|
- |
| 4.6.3, clause 6 of IS:2798:1998(Leakage test- a. Closure leakage ) |
- |
100.00 |
|
- |
| Cl. 4.5(Cl. 4.5 Wall Thickness (Top)) |
- |
400.00 |
|
Top, middle, bottom together |
| 4.5, IS:2798:1998(Wall thickness- Middle , in mm) |
- |
400.00 |
|
Top, middle, bottom together |
| 4.5, IS:2798:1998(Wall thickness- Bottom, in mm) |
- |
400.00 |
|
Top, middle, bottom together |
| 4.6.4, clause 8 of IS:2798:1998(Drop test ) |
- |
500.00 |
|
- |
| 4.6.2.1, Annex A(Transparency (Blue tint in polycarbonate & PET containers of 5 litre and above capacity)) |
- |
400.00 |
|
- |
| 4.6.2 Annex A(Transparency) |
- |
400.00 |
|
- |
| 4.4 (b)(Brimful Capacity) |
- |
400.00 |
|
- |
| 4.6.6 (chem)(Water Potability test (after 30 days) (a) Taste (b) Odour) |
- |
900.00 |
|
- |
| 4.6.5.1 (chem)(Colour migration (Caps)) |
- |
900.00 |
|
- |
| 4.6.5.1 (chem)(Colour migration (Container)) |
- |
900.00 |
|
- |
| 4.6.5 , IS:9845:1998 (chem)(Migration of Caps - a. Amount of extractive) |
- |
900.00 |
|
- |
| 4.6.5 , IS:9845:1998 (chem)(Migration- b. Amount of extractive) |
- |
900.00 |
|
- |
| 4.3(Workmanship, Finish & Appearance) |
- |
400.00 |
|
- |
| 4.2(Design, Shape & Dimension ) |
- |
200.00 |
|
- |
| 4.6.5 , IS:9845:1998 (chem)(Migration- a. Amount of extractive) |
- |
900.00 |
|
- |
| Cl.4.6.7.2 and 4.6.7.3, Table 3, (ix)(Phthalic acid, bis(2-ethylhexyl) ester (DEHP)) |
- |
4800.00 |
|
for metals and phthalic acid |
| CL 4.6.7.2 and 4.6.7.3, Table 3 (ix)(Phthalic acid, bis(2-ethylhexyl) ester (DEHP)) |
- |
4800.00 |
|
for metals and phthalic acid |
| Cl.4.6.7.2 and 4.6.7.3, Table 3, (i)(Barium) |
- |
4800.00 |
|
for metals and phthalic acid |
| Clauses 4.6.7.2 and 4.6.7.3 ,S.No(ii)(Specific migration for container,Cobalt) |
- |
4800.00 |
|
for metals and phthalic acid |
| Cl.4.6.7.2 and 4.6.7.3, Table 3, (iii)(Copper) |
- |
4800.00 |
|
for metals and phthalic acid |
| Cl.4.6.7.2 and 4.6.7.3, Table 3, (iv)(Iron) |
- |
4800.00 |
|
for metals and phthalic acid |
| Cl.4.6.7.2 and 4.6.7.3, Table 3, (v)(Lithium) |
- |
4800.00 |
|
for metals and phthalic acid |
| Cl.4.6.7.2 and 4.6.7.3, Table 3, (vi)(Manganese) |
- |
4800.00 |
|
for metals and phthalic acid |
| Cl.4.6.7.2 and 4.6.7.3, Table 3, (ii)(Cobalt) |
- |
4800.00 |
|
for metals and phthalic acid |
| Cl.4.6.7.2 and 4.6.7.3, Table 3, (vii)(Zinc) |
- |
4800.00 |
|
for metals and phthalic acid |
| Cl.4.6.7.2 and 4.6.7.3, Table 3, (viii)(Antimony) |
- |
4800.00 |
|
for metals and phthalic acid |
| CL 4.6.7.2 and 4.6.7.3, Table 3 (i)(Barium) |
- |
4800.00 |
|
for metals and phthalic acid |
| CL 4.6.7.2 and 4.6.7.3, Table 3 (ii)(Cobalt) |
- |
4800.00 |
|
for metals and phthalic acid |
| CL 4.6.7.2 and 4.6.7.3, Table 3 (iii)(Copper) |
- |
4800.00 |
|
for metals and phthalic acid |
| CL 4.6.7.2 and 4.6.7.3, Table 3 (iv)(Iron) |
- |
4800.00 |
|
for metals and phthalic acid |
| CL 4.6.7.2 and 4.6.7.3, Table 3 (v)(Lithium) |
- |
4800.00 |
|
for metals and phthalic acid |
| CL 4.6.7.2 and 4.6.7.3, Table 3 (vi)(Manganese) |
- |
4800.00 |
|
for metals and phthalic acid |
| CL 4.6.7.2 and 4.6.7.3, Table 3 (vii)(Zinc) |
- |
4800.00 |
|
for metals and phthalic acid |
| CL 4.6.7.2 and 4.6.7.3, Table 3 (viii)(Antimony) |
- |
4800.00 |
|
for metals and phthalic acid |
| Clauses 4.6.7.2 and 4.6.7.3 ,S.No(i)(Specific migration for container,Barium) |
- |
4800.00 |
|
for metals and phthalic acid |
| Clauses 4.6.7.2 and 4.6.7.3 ,S.No(iii)(Specific migration for container,Copper) |
- |
4800.00 |
|
for metals and phthalic acid |
| Clauses 4.6.7.2 and 4.6.7.3 ,S.No(iv)(Specific migration for container,Iron) |
- |
4800.00 |
|
for metals and phthalic acid |
| Clauses 4.6.7.2 and 4.6.7.3 ,S.No(v)(Specific migration for container,Lithium) |
- |
4800.00 |
|
for metals and phthalic acid |
| Clauses 4.6.7.2 and 4.6.7.3 ,S.No(vi)(Specific migration for container,Manganese) |
- |
4800.00 |
|
for metals and phthalic acid |
| Clauses 4.6.7.2 and 4.6.7.3 ,S.No(vii)(Specific migration for container,Zinc) |
- |
4800.00 |
|
for metals and phthalic acid |
| Clauses 4.6.7.2 and 4.6.7.3 ,S.No(viii)(Specific migration for container,Antimony) |
- |
4800.00 |
|
for metals and phthalic acid |
| Clauses 4.6.7.2 and 4.6.7.3 ,S.No(i)(Specific migration for Cap,Barium) |
- |
4800.00 |
|
for metals and phthalic acid |
| Clauses 4.6.7.2 and 4.6.7.3 ,S.No(ii)(Specific migration for Cap,Cobalt) |
- |
4800.00 |
|
for metals and phthalic acid |
| Clauses 4.6.7.2 and 4.6.7.3 ,S.No(iii)(Specific migration for Cap,Copper) |
- |
4800.00 |
|
for metals and phthalic acid |
| Clauses 4.6.7.2 and 4.6.7.3 ,S.No(iv)(Specific migration for Cap,Iron) |
- |
4800.00 |
|
for metals and phthalic acid |
| Clauses 4.6.7.2 and 4.6.7.3 ,S.No(v)(Specific migration for Cap,Lithium) |
- |
4800.00 |
|
for metals and phthalic acid |
| Clauses 4.6.7.2 and 4.6.7.3 ,S.No(vi)(Specific migration for Cap,Manganese) |
- |
4800.00 |
|
for metals and phthalic acid |
| Clauses 4.6.7.2 and 4.6.7.3 ,S.No(vii)(Specific migration for Cap,Zinc) |
- |
4800.00 |
|
for metals and phthalic acid |
| Clauses 4.6.7.2 and 4.6.7.3 ,S.No(viii)(Specific migration for Cap,Antimony) |
- |
4800.00 |
|
for metals and phthalic acid |
|
- |
- - |
| 5358 |
Arbro Pharmaceuticals Private Limited
| 8116816
| IS 15609 (2005) |
Polyethylene flexible pouches for the packing of natural mineral water and packaged drinking water - Specification |
Commercial Grade |
14500 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 6.1.1(Description) |
- |
150 |
|
No Discount |
| 6.1.2(Film Form) |
- |
150 |
|
No Discount |
| 6.1.3(Winding of the Film ) |
- |
150 |
|
No Discount |
| 6.1.4(Odour) |
- |
150 |
|
No Discount |
| 6.1.5 A-2 of IS: 2508:2016(Thickness) |
- |
150 |
|
No Discount |
| 6.1.6(Width) |
- |
150 |
|
No Discount |
| 6.1.7 IS: 9845:1998(Migration- a. Amount of extractive ) |
- |
1000 |
|
No Discount |
| 6.1.7 IS: 9845:1998(Migration- b. Colour migration) |
- |
1000 |
|
No Discount |
| 6.1.8 Annex 4 of IS:2508:2016(Tensile Strength a. Lengthwise direction) |
- |
300 |
|
No Discount |
| 6.1.8 Annex 4 of IS:2508:2016(Tensile Strength b. Crosswise direction) |
- |
300 |
|
No Discount |
| 6.1.9 Annex 4 of IS:2508:2016(Elongation at break - a. Lengthwise direction) |
- |
300 |
|
No Discount |
| 6.1.9 Annex 4 of IS:2508:2016(Elongation at break - b. Crosswise direction) |
- |
300 |
|
No Discount |
| 6.1.10 Annex -6 of IS:2508:2016(Dart impact Resistance) |
- |
600 |
|
No Discount |
| 7.1 Annex E(Water Potability test (after 30 Days) a) Taste b) Odour) |
- |
1500 |
|
No Discount |
| 7.2 Annex F(Stack Load test) |
- |
1200 |
|
No Discount |
| 7.3 Annex G(Drop test ) |
- |
300 |
|
No Discount |
| 7.4 Annex H(Ink adhesion test for printed pouches) |
- |
150 |
|
No Discount |
| 7.5 Annex J(Product resistance test for printed pouches) |
- |
150 |
|
No Discount |
| CL 6.1.11.2 and 6.1.11.3, Table 3 (i)(Barium) |
- |
300 |
|
No Discount |
| CL 6.1.11.2 and 6.1.11.3, Table 3 (ii)(Cobalt) |
- |
300 |
|
No Discount |
| CL 6.1.11.2 and 6.1.11.3, Table 3 (iii)(Copper) |
- |
300 |
|
No Discount |
| CL 6.1.11.2 and 6.1.11.3, Table 3 (iv)(Iron) |
- |
300 |
|
No Discount |
| CL 6.1.11.2 and 6.1.11.3, Table 3 (v)(Lithium) |
- |
300 |
|
No Discount |
| CL 6.1.11.2 and 6.1.11.3, Table 3 (vi)(Manganese) |
- |
300 |
|
No Discount |
| CL 6.1.11.2 and 6.1.11.3, Table 3 (vii)(Zinc) |
- |
300 |
|
No Discount |
| CL 6.1.11.2 and 6.1.11.3, Table 3 (viii)(Antimony) |
- |
300 |
|
No Discount |
| CL 6.1.11.2 and 6.1.11.3, Table 3 (ix)(Phthalic acid, bis(2-ethylhexyl) ester (DEHP)) |
- |
3600 |
|
No Discount |
| 7.1(Vibration Leakage Test) |
- |
500 |
|
No Discount |
|
14 Jan, 2029 |
- - |
| 5359 |
Sleen India Biz venture Private Limited, Agra
| 9139736
| IS 210 (2009) |
Grey iron castings - Specification (First Revision) |
CAST IRON PRODUCT-Grey iron castings |
7500 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 6(Chemical Composition(chemical
composition shall be as agreed to between the
purchaser and the manufacturer.)) |
- |
2000 |
|
- |
| 7.1(WORKMANSHIP AND FINISH) |
- |
150 |
|
- |
| 10.1(FREEDOM FROM DEFECTS) |
- |
200 |
|
Complete test price for cl.10 is 200/-. |
| 10.2(FREEDOM FROM DEFECTS) |
- |
0 |
|
Complete test price for cl.10 is 200/-. |
| 13(SIZE OF TEST BARS-Diameter) |
- |
150 |
|
- |
| 13(SIZE OF TEST BARS-Length) |
- |
0 |
|
Complete Test price for cl.13 is 200/-. |
| 15, Table 3(TENSIL.E TEST- IS 1608 Part1 ) |
- |
1000 |
|
- |
| 16, Table 3(Hardness Test) |
- |
1000 |
|
- |
| 17,Annex B(TRANSVERSE TEST) |
- |
1000 |
|
- |
| 18(HYDROSTATIC TEST) |
- |
1000 |
|
- |
| 6(Chemical Composition(chemical
composition shall be as agreed to between the
purchaser and the manufacturer.)) |
- |
0 |
|
Test price for cl.6 is 1500/-. |
| 7.1(WORKMANSHIP AND FINISH) |
- |
0 |
|
Complete test price for cl. 7 is 200 |
| 10.1(FREEDOM FROM DEFECTS) |
- |
0 |
|
Complete test price for cl.10 is 200/-. |
| 10.2(FREEDOM FROM DEFECTS) |
- |
0 |
|
Complete test price for cl.10 is 200/-. |
| 13(SIZE OF TEST BARS-Diameter) |
- |
0 |
|
Complete test price for cl.13 is 200/-. |
| 13(SIZE OF TEST BARS-Length) |
- |
0 |
|
Complete test price for cl.13 is 200/-. |
| 15, Table 3(TENSIL.E TEST- IS 1608 Part1 ) |
- |
0 |
|
Tensile test for cl.14 is 500/-. |
| 16, Table 3(Hardness Test) |
- |
0 |
|
Hardness test for cl.16 is 500/-. |
| 17,Annex B(TRANSVERSE TEST) |
- |
0 |
|
Transverse test for cl.17 is 500/-. |
| 18(HYDROSTATIC TEST) |
- |
0 |
|
hydrostatic test for cl.18 is 500/-. |
| 9(IS 7754) |
- |
0 |
|
Complete is price for cl.9 is 500/-. |
| 9(IS 7754) |
- |
0 |
|
Complete is price for cl.9 is 500/-. |
| 9(Microstructure) |
- |
0 |
|
Complete is price for cl.9 is 500/-. |
| 21(Marking) |
- |
50 |
|
- |
| 9(Microstructure) |
- |
0 |
|
Complete is price for cl.9 is 500/-. |
| 7.2(Casting dimensions) |
- |
550 |
|
- |
| Cl-6(Phosprorus (P) - IS 12308 ( P-5)) |
- |
400 |
|
- |
| 6(Chemical Composition(chemical
composition shall be as agreed to between the
purchaser and the manufacturer.)) |
- |
0 |
|
- |
| 7.1(WORKMANSHIP AND FINISH) |
- |
0 |
|
- |
| 10.1(FREEDOM FROM DEFECTS) |
- |
0 |
|
- |
| 10.2(FREEDOM FROM DEFECTS) |
- |
0 |
|
- |
| 13(SIZE OF TEST BARS-Diameter) |
- |
0 |
|
- |
| 13(SIZE OF TEST BARS-Length) |
- |
0 |
|
- |
| 15, Table 3(TENSIL.E TEST- IS 1608 Part1 ) |
- |
0 |
|
- |
| 16, Table 3(Hardness Test) |
- |
0 |
|
- |
| 17,Annex B(TRANSVERSE TEST) |
- |
0 |
|
- |
| 18(HYDROSTATIC TEST) |
- |
0 |
|
- |
| 6(Chemical Composition(chemical
composition shall be as agreed to between the
purchaser and the manufacturer.)) |
- |
0 |
|
- |
| 7.1(WORKMANSHIP AND FINISH) |
- |
0 |
|
- |
| 10.1(FREEDOM FROM DEFECTS) |
- |
0 |
|
- |
| 10.2(FREEDOM FROM DEFECTS) |
- |
0 |
|
- |
| 13(SIZE OF TEST BARS-Diameter) |
- |
0 |
|
- |
| 13(SIZE OF TEST BARS-Length) |
- |
0 |
|
- |
| 15, Table 3(TENSIL.E TEST- IS 1608 Part1 ) |
- |
0 |
|
- |
| 16, Table 3(Hardness Test) |
- |
0 |
|
- |
| 17,Annex B(TRANSVERSE TEST) |
- |
0 |
|
- |
| 18(HYDROSTATIC TEST) |
- |
0 |
|
- |
| 9(IS 7754) |
- |
0 |
|
- |
| 9(IS 7754) |
- |
0 |
|
- |
| 9(Microstructure) |
- |
0 |
|
- |
| 21(Marking) |
- |
0 |
|
- |
| 9(Microstructure) |
- |
0 |
|
- |
| 7.2(Casting dimensions) |
- |
0 |
|
- |
| Cl-6(Phosprorus (P) - IS 12308 ( P-5)) |
- |
0 |
|
- |
|
- |
- Included w.e.f 16.07.2025 |
| 5360 |
Ahmedabad Textile Industry's Research Association (ATIRA), Ahmedabad
| 7173002
| IS 7903 (2017) |
Textiles – Tarpaulins made from high density polyethylene (HDPE) woven fabrics – Specification (fifth revision) |
- |
55900 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 3.4( Line/ Cord beading
IS 7903) |
- |
200 |
|
- |
| 4.0(Types IS 7903) |
- |
0 |
|
- |
| 5.1.1(Lamination IS 7903) |
- |
0 |
|
- |
| 5.1.2(Lamination IS 7903) |
- |
0 |
|
- |
| 5.2.1(Construction IS 7903) |
- |
200 |
|
- |
| 5.2.1(Construction IS 7903) |
- |
200 |
|
- |
| 5.2.1(Construction IS 7903) |
- |
200 |
|
- |
| 5.2.1(Construction IS 7903) |
- |
200 |
|
- |
| 5.2.1(Construction IS 7903) |
- |
0 |
|
- |
| 5.2.1(Construction IS 7903) |
- |
0 |
|
- |
| 5.2.1(Construction IS 7903) |
- |
0 |
|
- |
| 5.2.1(Construction IS 7903) |
- |
0 |
|
- |
| 5.3(Joint/Seam, IS 7903) |
- |
200 |
|
- |
| 5.4(Fixing of Eyelets, IS 7903) |
- |
200 |
|
- |
| 5.4(Fixing of Eyelets ,IS 7903) |
- |
0 |
|
- |
| 6.1 Table 1,i)(No of HDPE fabric layers ,IS 7903) |
- |
200 |
|
- |
| 6.1 Table 1,ii)(No of lamination layers, IS 7903) |
- |
200 |
|
- |
| 6.1 Table 1, iii)(Total no of layers in the finished tarpaulin, IS 7903) |
- |
200 |
|
- |
| 6.1 Table 1,iv)(Mass of finished tarpaulin, Annex B ,IS 7903) |
- |
450 |
|
- |
| 6.1 Table 1,v)(Mass of laminated fabric, Annex C , IS 7903) |
- |
450 |
|
- |
| 6.1 Table 1vi)(Breaking strength before UV exposure,warp ,IS 1969 Part 1) |
- |
900 |
|
- |
| 6.1 Table 1vi)(Breaking strength before UV exposure,weft, IS 1969 part 1) |
- |
0 |
|
- |
| 6.1 Table 1 vii)(Elongation at break of fabric,warp, IS 1969 Part 1) |
- |
0 |
|
- |
| 6.1 Table 1 vii)(Elongation at break of fabric,weft, IS 1969 Part1) |
- |
0 |
|
- |
| 6.1 Table 1 viii)(Retention of breaking strength after UV exposure of 144h Warp, IS 13162 part 2& IS 1969 Part1 ) |
- |
13860 |
|
- |
| 6.1 Table 1 viii)(Retention of breaking strength after UV exposure of 144h Weft , IS 13162 part 2& IS 1969 Part1 ) |
- |
0 |
|
- |
| 6.1 Table 1 ix)(Welded seam strength before UV exposure (Weft) , IS 1969 Part 1) |
- |
800 |
|
- |
| 6.1 Table 1 x)(Retention of welded seam strength after UV exposure of 144h(Weft) ,IS 13162 part 2& IS 1969 Part1 ) |
- |
13760 |
|
- |
| 6.1 Table 1 xi)(Trapezoidal tear strength, IS 14293) |
- |
900 |
|
- |
| 6.1 Table 1 xii)(Puncture Resistance, Annex D of IS 7903) |
- |
1350 |
|
- |
| 6.1 Table 1 xiii)(Impact Failure load , at 1524 mmdrop, Annex E of IS 7903) |
- |
3000 |
|
- |
| 6.1 Table 1 xiv)(Color fastness to light (For color Tarpulines) , IS 2454) |
- |
1650 |
|
- |
| 6.1 Table 1 xv)(Ash Content, Annex F of IS 7903) |
- |
650 |
|
- |
| 6.2(Length, IS 7903) |
- |
200 |
|
- |
| 6.2(Width, IS 7903) |
- |
200 |
|
- |
| 6.2(height, IS 7903) |
- |
200 |
|
- |
| 6.3(Water Proofness,IS 7941) |
- |
1600 |
|
- |
| 6.3(Water Proofness, IS 7940) |
- |
700 |
|
- |
| 3.4( Line/ Cord beading
IS 7903) |
- |
0 |
|
- |
| 4.0(Types IS 7903) |
- |
0 |
|
- |
| 5.1.1(Lamination IS 7903) |
- |
0 |
|
- |
| 5.1.2(Lamination IS 7903) |
- |
0 |
|
- |
| 5.2.1(Construction IS 7903) |
- |
0 |
|
- |
| 5.2.1(Construction IS 7903) |
- |
0 |
|
- |
| 5.2.1(Construction IS 7903) |
- |
0 |
|
- |
| 5.2.1(Construction IS 7903) |
- |
0 |
|
- |
| 5.2.1(Construction IS 7903) |
- |
0 |
|
- |
| 5.2.1(Construction IS 7903) |
- |
0 |
|
- |
| 5.2.1(Construction IS 7903) |
- |
0 |
|
- |
| 5.2.1(Construction IS 7903) |
- |
0 |
|
- |
| 5.3(Joint/Seam, IS 7903) |
- |
0 |
|
- |
| 5.4(Fixing of Eyelets, IS 7903) |
- |
0 |
|
- |
| 5.4(Fixing of Eyelets ,IS 7903) |
- |
0 |
|
- |
| 6.1 Table 1,i)(No of HDPE fabric layers ,IS 7903) |
- |
0 |
|
- |
| 6.1 Table 1,ii)(No of lamination layers, IS 7903) |
- |
0 |
|
- |
| 6.1 Table 1, iii)(Total no of layers in the finished tarpaulin, IS 7903) |
- |
0 |
|
- |
| 6.1 Table 1,iv)(Mass of finished tarpaulin, Annex B ,IS 7903) |
- |
0 |
|
- |
| 6.1 Table 1,v)(Mass of laminated fabric, Annex C , IS 7903) |
- |
0 |
|
- |
| 6.1 Table 1vi)(Breaking strength before UV exposure,warp ,IS 1969 Part 1) |
- |
0 |
|
- |
| 6.1 Table 1vi)(Breaking strength before UV exposure,weft, IS 1969 part 1) |
- |
0 |
|
- |
| 6.1 Table 1 vii)(Elongation at break of fabric,warp, IS 1969 Part 1) |
- |
0 |
|
- |
| 6.1 Table 1 vii)(Elongation at break of fabric,weft, IS 1969 Part1) |
- |
0 |
|
- |
| 6.1 Table 1 viii)(Retention of breaking strength after UV exposure of 144h Warp, IS 13162 part 2& IS 1969 Part1 ) |
- |
0 |
|
- |
| 6.1 Table 1 viii)(Retention of breaking strength after UV exposure of 144h Weft , IS 13162 part 2& IS 1969 Part1 ) |
- |
0 |
|
- |
| 6.1 Table 1 ix)(Welded seam strength before UV exposure (Weft) , IS 1969 Part 1) |
- |
0 |
|
- |
| 6.1 Table 1 x)(Retention of welded seam strength after UV exposure of 144h(Weft) ,IS 13162 part 2& IS 1969 Part1 ) |
- |
0 |
|
- |
| 6.1 Table 1 xi)(Trapezoidal tear strength, IS 14293) |
- |
0 |
|
- |
| 6.1 Table 1 xii)(Puncture Resistance, Annex D of IS 7903) |
- |
0 |
|
- |
| 6.1 Table 1 xiii)(Impact Failure load , at 1524 mmdrop, Annex E of IS 7903) |
- |
0 |
|
- |
| 6.1 Table 1 xiv)(Color fastness to light (For color Tarpulines) , IS 2454) |
- |
0 |
|
- |
| 6.1 Table 1 xv)(Ash Content, Annex F of IS 7903) |
- |
0 |
|
- |
| 6.2(Length, IS 7903) |
- |
0 |
|
- |
| 6.2(Width, IS 7903) |
- |
0 |
|
- |
| 6.2(height, IS 7903) |
- |
0 |
|
- |
| 6.3(Water Proofness,IS 7941) |
- |
0 |
|
- |
| 6.3(Water Proofness, IS 7940) |
- |
0 |
|
- |
| 6.2(dimension(l)) |
- |
0 |
|
- |
| 6.2(dimension(w)) |
- |
0 |
|
- |
| 6.2(dimension(h)) |
- |
0 |
|
- |
| 3.3(Eyelets (Dimesnions) i) Starting thickness of metal Aluminium min ii) Outside dia of flange‘A’
iii) Flange formed height ‘B’
iv) Pierced dia ‘C’
v) Overall length ‘D’
vi) Internal dia of Barrel when closed ‘E’ min
vii) Thickness of compressed material between eyelet and washer F’ max
viii) Outside diameter of barrel under the flange‘G’
) |
- |
400 |
|
- |
| 3.3(Eyelets) |
- |
0 |
|
- |
| 3.2(HDPE Fabric (Material Identification)) |
- |
500 |
|
- |
| 3.1(HDPE Tapes (Carbon Black Content)) |
- |
550 |
|
- |
| 3.1(HDPE Tapes (Presence of UV-stabiliser)) |
- |
0 |
|
- |
| 3.1(HDPE Tapes (Material Identification)) |
- |
0 |
|
- |
| 3.1() |
- |
0 |
|
- |
| 3.1() |
- |
0 |
|
- |
| 3.1() |
- |
0 |
|
- |
| 3.1() |
- |
0 |
|
- |
| 3.1() |
- |
0 |
|
- |
| 4() |
- |
0 |
|
- |
| 5.1.1(Coating Thickness) |
- |
700 |
|
- |
| 5.1.1(Carbon Black Content) |
- |
550 |
|
- |
| 5.1.1(Sandwich lamination thickness) |
- |
450 |
|
- |
| 5.1.1(Mass of Finished Tarpaulin) |
- |
0 |
|
- |
| 5.1.1(UV Exposure (144 hrs)) |
- |
0 |
|
- |
| 5.1.1(Agening) |
- |
10080 |
|
- |
|
- |
- Included w.e.f 26.05.2025 |
| 5361 |
CIPET, Jaipur
| 8122834
| IS 2833 (2019) |
Aniline, technical - Specification (Second Revision) |
Aniline, Technical - Specification |
16300 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl.2.1(Description) |
- |
1000 |
|
Include packing and marking charges also |
| Cl.2.2.1(Relative Density at 27/27 0C) |
- |
1000 |
|
- |
| Cl.2.2.2(Crystallizing Point) |
- |
2200 |
|
- |
| Cl.2.2.4(Assay, percent by Nitrite value) |
- |
2000 |
|
- |
| Cl.2.2.5(Nitrobenzene content by GC, ppm) |
- |
3200 |
|
- |
| Cl.2.2.3(Distillation Range) |
- |
2200 |
|
- |
| Cl.2.2.4(Assay, percent by GC) |
- |
3200 |
|
- |
| Cl.2.2.6(Moisture content, percent by mass) |
- |
1500 |
|
- |
| Cl.2.1(Description) |
- |
0 |
|
- |
| Cl.2.2.1(Relative Density at 27/27 0C) |
- |
0 |
|
- |
| Cl.2.2.2(Crystallizing Point) |
- |
0 |
|
- |
| Cl.2.2.4(Assay, percent by Nitrite value) |
- |
0 |
|
- |
| Cl.2.2.5(Nitrobenzene content by GC, ppm) |
- |
0 |
|
- |
| Cl.2.2.3(Distillation Range) |
- |
0 |
|
- |
| Cl.2.2.4(Assay, percent by GC) |
- |
0 |
|
- |
| Cl.2.2.6(Moisture content, percent by mass) |
- |
0 |
|
- |
| Cl.2.1(Description) |
- |
0 |
|
- |
| Cl.2.2.1(Relative Density at 27/27 0C) |
- |
0 |
|
- |
| Cl.2.2.2(Crystallizing Point) |
- |
0 |
|
- |
| Cl.2.2.3(Distillation Range) |
- |
0 |
|
- |
| Cl.2.2.4(Assay, percent by Nitrite value) |
- |
0 |
|
- |
| Cl.2.2.4(Assay, percent by GC) |
- |
0 |
|
- |
| Cl.2.2.5(Nitrobenzene content by GC, ppm) |
- |
0 |
|
- |
| Cl.2.2.6(Moisture content, percent by mass) |
- |
0 |
|
- |
| Cl.2.1(Description) |
- |
0 |
|
- |
| Cl.2.2.1(Relative Density at 27/27 0C) |
- |
0 |
|
- |
| Cl.2.2.2(Crystallizing Point) |
- |
0 |
|
- |
| Cl.2.2.3(Distillation Range) |
- |
0 |
|
- |
| Cl.2.2.4(Assay, percent by Nitrite value) |
- |
0 |
|
- |
| Cl.2.2.4(Assay, percent by GC) |
- |
0 |
|
- |
| Cl.2.2.5(Nitrobenzene content by GC, ppm) |
- |
0 |
|
- |
| Cl.2.2.6(Moisture content, percent by mass) |
- |
0 |
|
- |
| Cl.2.1(Description) |
- |
0 |
|
- |
| Cl.2.2.1(Relative Density at 27/27 0C) |
- |
0 |
|
- |
| Cl.2.2.2(Crystallizing Point) |
- |
0 |
|
- |
| Cl.2.2.3(Distillation Range) |
- |
0 |
|
- |
| Cl.2.2.4(Assay, percent by Nitrite value) |
- |
0 |
|
- |
| Cl.2.2.4(Assay, percent by GC) |
- |
0 |
|
- |
| Cl.2.2.5(Nitrobenzene content by GC, ppm) |
- |
0 |
|
- |
| Cl.2.2.6(Moisture content, percent by mass) |
- |
0 |
|
- |
| Cl.2.1(Description) |
- |
0 |
|
- |
| Cl.2.2.1(Relative Density at 27/27 0C) |
- |
0 |
|
- |
| Cl.2.2.2(Crystallizing Point) |
- |
0 |
|
- |
| Cl.2.2.3(Distillation Range) |
- |
0 |
|
- |
| Cl.2.2.4(Assay, percent by Nitrite value) |
- |
0 |
|
- |
| Cl.2.2.4(Assay, percent by GC) |
- |
0 |
|
- |
| Cl.2.2.5(Nitrobenzene content by GC, ppm) |
- |
0 |
|
- |
| Cl.2.2.6(Moisture content, percent by mass) |
- |
0 |
|
- |
|
21 Feb, 2029 |
- Included w.e.f.03.06.2025 |
| 5362 |
MARQUIS TECHNOLOGIES PRIVATE LIMITED, NOIDA
| 8175126
| IS 16107 : Part 2 : Sec 1 (2012) |
Luminaires performance: Part 2 particular requirements: Sec 1 led luminaire |
- |
50000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 10(LED Luminaire
Life) |
- |
15000 |
|
- |
| 9(Chromaticity
Coordinates,
Correlated
colour temperature
and colour rendering) |
- |
15000 |
|
- |
| 8(Light Output) |
- |
10000 |
|
- |
| 7(Total Input Power) |
- |
15000 |
|
- |
|
13 Dec, 2026 |
- Included w.e.f 19.05.2025 |
| 5363 |
Institute for Auto Parts and Hand Tools Technology, Ludhiana
| 9126034
| IS 274 : Part 1 and 2 (1981) |
Specification for shovels: Part 1 genral purpose shovels: Part 2 heat - Treated shovels (Third Revision) |
All Grade/Type/Size/Designation per the IS 274 (Pt 1&2) |
8200 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4.1(Sulphur) |
- |
200 |
|
- S = Rs.100/- per element (As per IS 274 Part-I)
- S = Rs.100/- per element (As per IS 274 Part-II) |
| 4.1(Phosphorus) |
- |
200 |
|
- P = Rs.100/- per element (As per IS 274 Part-I)
- P = Rs.100/- per element (As per IS 274 Part-II) |
| 5 Table-1,2(Shape) |
- |
2400 |
|
Rs. 1200/- as per IS 274 (Part-I)
Rs. 1200/- as per IS 274 (Part-II) |
| 5 Table-1,2(Dimensions- A) |
- |
0 |
|
- |
| 5 Table-1,2(Dimensions- B) |
- |
0 |
|
- |
| 5 Table-1,2(Dimensions- C) |
- |
0 |
|
- |
| 5 Table-1,2(Dimensions- D) |
- |
0 |
|
- |
| 5 Table-1,2(Dimensions- E) |
- |
0 |
|
- |
| 5 Table-1,2(Dimensions- G) |
- |
0 |
|
- |
| 5 Table-1,2(Dimensions- H) |
- |
0 |
|
- |
| 5 Table-1,2(Dimensions- K) |
- |
0 |
|
- |
| 5 Table-1,2(Dimensions- L) |
- |
0 |
|
- |
| 6.1(Blade thickness) |
- |
0 |
|
- |
| 7.0(Mass) |
- |
0 |
|
- |
| 8.0(Manufacture) |
- |
0 |
|
- |
| 8.0(Manufacture) |
- |
0 |
|
- |
| 8.0(Manufacture) |
- |
0 |
|
- |
| 9.1(Handles) |
- |
0 |
|
- |
| 9.3(Handles) |
- |
0 |
|
- |
| 11.0(Workmanship & Finish
) |
- |
1000 |
|
Rs. 500/- as per IS 274 (Part-I)
Rs. 500/- as per IS 274 (Part-II) |
| 12.0(Preservative Treatment
) |
- |
0 |
|
- |
| 14.2(Bending Test) |
- |
0 |
|
- |
| 14.3(Flexing Test) |
- |
0 |
|
- |
| 4.1(Sulphur) |
- |
0 |
|
- |
| 4.1(Phosphorus) |
- |
0 |
|
- |
| 5 Table-1,2(Shape) |
- |
0 |
|
- |
| 5 Table-1,2(Dimensions- A) |
- |
0 |
|
- |
| 5 Table-1,2(Dimensions- B) |
- |
0 |
|
- |
| 5 Table-1,2(Dimensions- C) |
- |
0 |
|
- |
| 5 Table-1,2(Dimensions- D) |
- |
0 |
|
- |
| 5 Table-1,2(Dimensions- E) |
- |
0 |
|
- |
| 5 Table-1,2(Dimensions- G) |
- |
0 |
|
- |
| 5 Table-1,2(Dimensions- H) |
- |
0 |
|
- |
| 5 Table-1,2(Dimensions- K) |
- |
0 |
|
- |
| 5 Table-1,2(Dimensions- L) |
- |
0 |
|
- |
| 6.1(Blade thickness) |
- |
0 |
|
- |
| 7.0(Mass) |
- |
0 |
|
- |
| 8.0(Manufacture) |
- |
0 |
|
- |
| 8.0(Manufacture) |
- |
0 |
|
- |
| 8.0(Manufacture) |
- |
0 |
|
- |
| 9.1(Handles) |
- |
400 |
|
Hardness As per IS 274 (Part-II) Clause no. 9.0 |
| 9.3(Handles) |
- |
0 |
|
- |
| 11.0(Workmanship & Finish
) |
- |
500 |
|
- |
| 12.0(Preservative Treatment
) |
- |
0 |
|
- |
| 14.2(Bending Test) |
- |
1000 |
|
Rs. 1000/- as per IS 274 (Part-I)
Rs. 1000/- as per IS 274 (Part-II) |
| 14.3(Flexing Test) |
- |
1000 |
|
Rs. 1000/- as per IS 274 (Part-I)
Rs. 1000/- as per IS 274 (Part-II) |
| 4.0(PHOSPHORUS) |
- |
0 |
|
- |
| 4.0(SULPHUR) |
- |
0 |
|
- |
|
17 Feb, 2028 |
- - |
| 5364 |
Institute for Auto Parts and Hand Tools Technology, Ludhiana
| 9126034
| IS 4003 : Part 1 (1978) |
Specification for pipe wrenches: Part 1 general purpose (First Revision) |
All Grade/Type/Size/Designation per IS 4003-1:2024 |
13520 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 3(Dimensions- Nominal Size) |
- |
1200 |
|
- |
| 4 AND AS PER IS 1570 PART 4(CARBON) |
- |
6620 |
|
- |
| 4 AND AS PER IS 1570 PART 2(SULPHUR) |
- |
0 |
|
- |
| 4 AND AS PER IS 1570 PART 2(PHOSPHORUS) |
- |
0 |
|
- |
| 4 AND AS PER IS 1570 PART 2(MANGANESE) |
- |
0 |
|
- |
| 4 AND AS PER IS 1570 PART 4(SILICON) |
- |
0 |
|
- |
| 4 AND AS PER IS 1570 PART 4(CHROMIUM) |
- |
0 |
|
- |
| 5(Hardness- Jaws) |
- |
1200 |
|
- |
| 7(Workmanship & Finish) |
- |
500 |
|
- |
| 13.1(Static Load Test) |
- |
2000 |
|
- |
| 5(Hardness- Shank of movable Jaw) |
- |
0 |
|
- |
| 4 AND AS PER IS 1570 PART 4(ALUMINIUM) |
- |
0 |
|
- |
| 4 AND AS PER IS 1570 PART 4(VANADIM) |
- |
0 |
|
- |
| 4 AND AS PER IS 1570 PART 4(BORON) |
- |
0 |
|
- |
| 4 AND AS PER IS 1570 PART 4(NICKEL) |
- |
0 |
|
- |
| 3(Dimensions-Minimum capacity) |
- |
0 |
|
- |
| 3(Dimensions-Maximum capacity, D) |
- |
0 |
|
- |
| 3(Dimensions- Jaw Thickness,T min) |
- |
0 |
|
- |
| 3(Dimensions- Length of movablejae, l1) |
- |
0 |
|
- |
| 3(Dimensions- Length of Handle, l2) |
- |
0 |
|
- |
| 3(Dimensions- Width of Nut, N) |
- |
0 |
|
- |
| 5(Hardness- Handle of movable Jaw) |
- |
0 |
|
- |
| 6.1(Manufacture- Handel) |
- |
0 |
|
- |
| 6.1(Manufacture- Handel) |
- |
0 |
|
- |
| 6.2(Manufacture- Movable Jaw) |
- |
0 |
|
- |
| 6.2(Manufacture- Movable Jaw) |
- |
0 |
|
- |
| 6.2(Manufacture- Movable Jaw) |
- |
0 |
|
- |
| 6.3(Manufacture- Adjusting Nut) |
- |
0 |
|
- |
| 6.3(Manufacture- Adjusting Nut) |
- |
0 |
|
- |
| 6.4(Manufacture- Frame) |
- |
0 |
|
- |
| 6.5(Manufacture- Hinge Pin) |
- |
0 |
|
- |
| 6.6(Manufacture- Spring) |
- |
0 |
|
- |
| 6.6(Manufacture- Spring) |
- |
0 |
|
- |
| 6.6(Manufacture- Spring) |
- |
0 |
|
- |
| 7(Workmanship & Finish) |
- |
0 |
|
- |
| 7(Workmanship & Finish) |
- |
0 |
|
- |
| 8(Operation) |
- |
0 |
|
- |
| 8(Operation) |
- |
0 |
|
- |
| 13.1(Static Load Test) |
- |
0 |
|
- |
| 13.2(Static- Shock Load Test) |
- |
2000 |
|
- |
| 13.2(Static- Shock Load Test) |
- |
0 |
|
- |
| 4 AND AS PER IS 1570 PART 4(MOLYBDENUM) |
- |
0 |
|
- |
| 4 AND AS PER IS 1570 PART 4(MANGANESE) |
- |
0 |
|
- |
| 4 AND AS PER IS 1570 PART 2(CARBON) |
- |
0 |
|
- |
|
17 Feb, 2028 |
- - |
| 5365 |
Institute for Auto Parts and Hand Tools Technology, Ludhiana
| 9126034
| IS 844 : Part 3 (1979) |
Specification for screw drivers: Part 3 dimensions for screw drivers for recessed head screws (Second Revision) |
AllGrade/Type/Size/Designation as per IS 844 (Part-III) |
3840 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 6 Table 1 & 2(Torque Test) |
- |
500 |
|
- |
| 4(Hardness) |
- |
400 |
|
- |
| 3 , IS 844 (P- 1)(Finish) |
- |
1000 |
|
Finish
Coating |
| 3 , IS 844 (P- 1)(Coating) |
- |
740 |
|
- C, Si, Mn, S, P -100/ element= 500/-
- Cr, V - 120/element = Rs. 240/- |
| 2.1( Dimension, d1) |
- |
1200 |
|
For complete dimensional inspection |
| 2.4(h) |
- |
0 |
|
- |
| 2.4(l) |
- |
0 |
|
- |
| 2.3(S) |
- |
0 |
|
- |
| 2.2( Dimension, d) |
- |
0 |
|
- |
| 2.1( Dimension, β) |
- |
0 |
|
- |
| 2.1( Dimension, α) |
- |
0 |
|
- |
| 2.1( Dimension, lmin) |
- |
0 |
|
- |
| 2.1( Dimension, f) |
- |
0 |
|
- |
| 2.1( Dimension, e) |
- |
0 |
|
- |
| 2.1( Dimension, d2) |
- |
0 |
|
- |
|
17 Feb, 2028 |
- - |
| 5366 |
CENTRAL LEATHER RESEARCH INSTITUTE (CSIR-CLRI), CHENNAI
| 6167704
| IS 15844 : Part 2 (2023) |
SPORTS FOOTWEAR PART -2 PERFORMANCE SPORTS FOOTWEAR |
- |
38000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 7.1.2(Upper to Mid Sole/Out Sole Bond Performance) |
- |
200 |
|
- |
| 7.1.3("Upper to Composite Sole Bond Performance
(Applicable Only When the Sole is Composite)") |
- |
0 |
|
- |
| 7.1.4(Out Sole to Mid Sole (Multilayer) Bond Performance) |
- |
0 |
|
- |
| 7.1.5(Energy Absorption at Seat Region) |
- |
1000 |
|
- |
| 7.1.6(Complete Shoe Flexing) |
- |
1000 |
|
- |
| 7.1.7(Washability) |
- |
500 |
|
- |
| 7.1.8(Slip Resistance) |
- |
1000 |
|
- |
| 7.1.9(Heel Drop) |
- |
200 |
|
- |
| 7.2 , Table No. 2 , i)(Flexing resistance) |
- |
500 |
|
- |
| 7.2 , Table No. 2 , ii)(Tear strength (average force)) |
- |
400 |
|
- |
| 7.2 , Table No. 2 , iii)("Colour fastness rubbing (To and fro) Grey scale rate
Dry: (rubbing) Rating: (Marring and staining) ") |
- |
400 |
|
- |
| 7.2 , Table No. 2 , iv) ,a)(Water vapour permeability) |
- |
600 |
|
- |
| 7.2 , Table No. 2 , iv) ,b)(Water vapour coefficient) |
- |
200 |
|
- |
| 7.2 , Table No. 2 , v)(Stitch tear strength (double hole)) |
- |
400 |
|
- |
| 7.2 , Table No. 2 , vi)("Colour fastness to light (Optional) Grey scale rate,
Rating: (Marring)") |
- |
1000 |
|
- |
| 7.2 , Table No. 2 , vii)(Tensile strength) |
- |
400 |
|
- |
| 7.2 , Table No. 2 , viii)(Elongation at break,) |
- |
0 |
|
- |
| 7.2 , Table No. 2 , ix)("Water penetration and water absorption after 60 Minutes
Water absorption %, Max Water penetration Gms, Max") |
- |
400 |
|
- |
| 7.2 , Table No. 2 , x)(Abrasion test (for unlined upper)) |
- |
1000 |
|
- |
| 7.2 , Table No. 3 , i)(Breaking strength
"As per Method 1 of IS 7016 (Part 2)/
ISO 1421 : 2016 or ISO 17706") |
- |
0 |
|
- |
| 7.2 , Table No. 3 , ii)(Elongation at break) |
- |
0 |
|
- |
| 7.2 , Table No. 3 , iii)(Tear strength, N, Min For Fabric: For all other materials) |
- |
0 |
|
- |
| 7.2 , Table No. 3 , iv)(Strength at needle perforation) |
- |
600 |
|
- |
| 7.2 , Table No. 3 , v)("Flexing resistance, no crack/damage to coating/ lamination
/ upper material till prescribed cycles") |
- |
0 |
|
- |
| 7.2 , Table No. 3 , vii)(Hydrolysis resistance) |
- |
600 |
|
- |
| 7.2 , Table No. 3 , viii)(Colour fastness to light grey scale rate) |
- |
0 |
|
- |
| 7.2 , Table No. 3 , ix)(Bursting Strength,) |
- |
500 |
|
- |
| 7.3 , Table No. 4 , i)(Tear strength,) |
- |
0 |
|
- |
| 7.3 , Table No. 4 , ii)(Abrasion resistance, cycles) |
- |
0 |
|
- |
| 7.3 , Table No. 4 , iii)("Colour fastness to rubbing (crocking), Grey scale
rate with 10 rubs on dry or wet, ") |
- |
0 |
|
- |
| 7.3 , Table No. 4 , iv)("Colour fastness to perspiration (contact method)
Grey scale rate, ") |
- |
600 |
|
- |
| 7.4 , Table No. 5 , i)(Thickness) |
- |
200 |
|
- |
| 7.4 , Table No. 5 , ii)(Flexing index) |
- |
400 |
|
- |
| 7.4 , Table No. 5 , iii)(Abrasion resistance, at 400 cycles) |
- |
400 |
|
- |
| 7.4 , Table No. 5 , iv) , a)(Water Absorption,) |
- |
400 |
|
- |
| 7.4 , Table No. 5 , iv) , b)(Water Desorption) |
- |
200 |
|
- |
| 7.5 , Table No. 6 , i)(Thickness) |
- |
0 |
|
- |
| 7.5 , Table No. 6 , iii) , a)(Water Absorption) |
- |
0 |
|
- |
| 7.5 , Table No. 6 , iii) , b)(Water Desorption) |
- |
0 |
|
- |
| 7.5 , Table No. 6 , iv)(Heat resistance shrinkage linear) |
- |
400 |
|
- |
| 7.6 , Table No. 7 , i)(Abrasion resistance (volume loss)) |
- |
500 |
|
- |
| 7.6 , Table No. 7 , ii)(Flexing resistance) |
- |
600 |
|
- |
| 7.6 , Table No. 7 , iii)(Hydrolysis resistance, cut growth after 1 50 000 flexes) |
- |
600 |
|
- |
| 7.6 , Table No. 7 , iv)(Tear strength) |
- |
400 |
|
- |
| 7.6 , Table No. 7 , v)(Tensile strength) |
- |
400 |
|
- |
| 7.6 , Table No. 7 , vi)(Elongation at break) |
- |
0 |
|
- |
| 7.6 , Table No. 7 , vii)(Compression set) |
- |
0 |
|
- |
| 7.7 , Table No. 8 , i)(Compression set) |
- |
0 |
|
- |
| 7.7 , Table No. 8 , ii)(Split tear strength,) |
- |
400 |
|
- |
| 7.7 , Table No. 8 , iii)(Heat shrinkage,) |
- |
400 |
|
- |
| 7.7 , Table No. 8 , iv)(Elongation at break,) |
- |
0 |
|
- |
| 7.8 , Table No. 9 , i)(First dry collapsing load, hardness) |
- |
200 |
|
- |
| 7.8 , Table No. 9 , ii)(Resilience) |
- |
200 |
|
- |
| 7.8 , Table No. 9 , iii)(Moisture resistance) |
- |
200 |
|
- |
| 7.8 , Table No. 9 , iv) , a)(Initial dry area shape retention) |
- |
200 |
|
- |
| 7.8 , Table No. 9 , iv) , b)(Area shape retention after 10th collapse, dry) |
- |
200 |
|
- |
| 7.8 , Table No. 9 , v)(Peel strength) |
- |
400 |
|
- |
| 7.9 , Table No. 10 , i)(Peel strength) |
- |
400 |
|
- |
| 7.9 , Table No. 10 , ii)(Shear strength) |
- |
400 |
|
- |
| 7.10 , Table No. 11 , i)(Limit of useful extension,) |
- |
400 |
|
- |
| 7.10 , Table No. 11 , ii)(Needle strength,) |
- |
400 |
|
- |
| 7.11 , Table No. 12 , i)(Breaking strength of lace,) |
- |
200 |
|
- |
| 7.11 , Table No. 12 , ii)(Lace tag strength,) |
- |
400 |
|
- |
| 7.11 , Table No. 12 , iii)(Lace to lace abrasion,) |
- |
400 |
|
- |
| 7.11 , Table No. 12 , iv)("Colour fastness to water
Gray Scale Rate") |
- |
400 |
|
- |
| 7.11 , Table No. 12 , v)(Strength of Buckle/Ski hook) |
- |
400 |
|
- |
| 7.11 , Table No. 12 , vi)(Corrosion resistance) |
- |
400 |
|
PHYSICAL PARAMETER ONLY
Rs.22000 |
| 7.12("Chemical Requirement on Complete Product
for All Types of Sports Shoe") |
- |
15000 |
|
CHEMICAL PARAMTER ONLY
Rs.15000 |
| 8(MARKING AND PACKING) |
- |
0 |
|
- |
| 7.12, Table no. 1 of IS 17011,(i)(Allergenic and carcinogenic disperse dyes) |
- |
1000 |
|
- |
| 7.12, Table no. 1 of IS 17011,(ii)(Aromatic amines released from Azo dyes (each individual amine)) |
- |
2000 |
|
- |
| 7.12, Table no. 1 of IS 17011,(iii)(Aromatic amines released from Azo dyes (each individual amine)) |
- |
2000 |
|
- |
| 7.12, Table no. 1 of IS 17011,(iv)(Chromium (VI)) |
- |
2000 |
|
- |
| 7.12, Table no. 1 of IS 17011,(v)(Dimethyl fumarate (DMFU)) |
- |
1000 |
|
- |
| 7.12, Table no. 1 of IS 17011,(vi)(Formaldehyde (free or released by partial hydrolysis)) |
- |
1000 |
|
- |
| 7.12, Table no. 1 of IS 17011,(vii)(Formaldehyde) |
- |
1000 |
|
- |
| 7.12, Table no. 1 of IS 17011,(viii)(Organotin compounds) |
- |
1000 |
|
- |
| 7.12, Table no. 1 of IS 17011,(ix)(PCP-TeCP-TriCP polychlorophenols) |
- |
1000 |
|
- |
| 7.12, Table no. 1 of IS 17011,(x)(pH) |
- |
1000 |
|
- |
| 7.12, Table no. 1 of IS 17011,(xi)(Phthalates (each individual phthalate)) |
- |
1000 |
|
- |
| 7.12, Table no. 1 of IS 17011,(xii)(Nickel, on skin contact 2-(thiocyanomethylthio) -benzothiazole (TCMTB)) |
- |
1000 |
|
- |
| 7.5 , Table No. 6 , ii)(Abrasion resistance, cycles
As per IS 15298 (Part 1)) |
- |
0 |
|
- |
| 7.1.1(Whole Footwear) |
- |
0 |
|
- |
| 7.12.2 (Amendment 1)(Lead content) |
- |
1000 |
|
- |
|
02 May, 2027 |
- - |
| 5367 |
Alpha Test House Services LLP (160), Sahibzada Ajit Singh Nagar
| 9138706
| IS 5872 (2025) |
Steel strapping for packaging ( Third Revision) |
- |
10000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Clause. 5.0(Carbon) |
- |
10000 |
|
- |
| Clause. 5.0(Silicon) |
- |
10000 |
|
- |
| Clause. 5.0(Manganese) |
- |
10000 |
|
- |
| Clause. 5.0(Sulphur) |
- |
10000 |
|
- |
| Clause. 5.0(Phosphorus) |
- |
10000 |
|
- |
| Clause. 5.0(Boron) |
- |
10000 |
|
- |
| Clause. 5.0(Niobium) |
- |
10000 |
|
- |
| Clause. 5.0(Vanadium) |
- |
10000 |
|
- |
| Clause. 5.0(Titanium) |
- |
10000 |
|
- |
| Clause. 6.0(Tensile Test) |
- |
10000 |
|
- |
| Clause. 6.0(Elongation test) |
- |
10000 |
|
- |
| Clause. 7.0(Reverse Bend Test) |
- |
10000 |
|
- |
| Clause. 8.0(Retest) |
- |
10000 |
|
- |
| Clause. 9.0(Freedom From Defects) |
- |
10000 |
|
- |
| Clause.10.0(Dimension , Shape & Tolerance) |
- |
10000 |
|
- |
| Clause.11.0(Surface Finish) |
- |
10000 |
|
- |
| Clause.12.0(Corrosion Resistance) |
- |
10000 |
|
- |
| Clause.13.0(Packing) |
- |
10000 |
|
- |
| Clause.14.0(Marking) |
- |
10000 |
|
- |
| Clause. 5.0(Carbon) |
- |
10000 |
|
- |
| Clause. 5.0(Silicon) |
- |
10000 |
|
- |
| Clause. 5.0(Manganese) |
- |
10000 |
|
- |
| Clause. 5.0(Sulphur) |
- |
10000 |
|
- |
| Clause. 5.0(Phosphorus) |
- |
10000 |
|
- |
| Clause. 5.0(Boron) |
- |
10000 |
|
- |
| Clause. 5.0(Niobium) |
- |
10000 |
|
- |
| Clause. 5.0(Vanadium) |
- |
10000 |
|
- |
| Clause. 5.0(Titanium) |
- |
10000 |
|
- |
| Clause. 6.0(Tensile Test) |
- |
10000 |
|
- |
| Clause. 6.0(Elongation test) |
- |
10000 |
|
- |
| Clause. 7.0(Reverse Bend Test) |
- |
10000 |
|
- |
| Clause. 8.0(Retest) |
- |
10000 |
|
- |
| Clause. 9.0(Freedom From Defects) |
- |
10000 |
|
- |
| Clause.10.0(Dimension , Shape & Tolerance) |
- |
10000 |
|
- |
| Clause.11.0(Surface Finish) |
- |
10000 |
|
- |
| Clause.12.0(Corrosion Resistance) |
- |
10000 |
|
- |
| Clause.13.0(Packing) |
- |
10000 |
|
- |
| Clause.14.0(Marking) |
- |
10000 |
|
- |
|
31 Dec, 2026 |
- Included w.e.f.24.04.2025 |
| 5368 |
BIS, Northern Regional Laboratory (NRL)
| None
| IS 10908 (2023) |
FLEXIBLE RUBBER TUBING FOR LIQUEFIED PETROLEUM GAS SPECIFICATION Second Revision |
- |
- View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4.3.1 (The tubing when supplied in 6.4 mm inside diameter; the tolerance as per table-1) |
- |
|
|
|
| 4.4.1 (When tested in accordance with the method given in Annex B, the tubing shall fit over the standard and oversize metal nozzle shown in Fig. 1, 2 and 3.) |
- |
|
|
|
| 4.4.2 ("When tested in accordance with the method given in Annex B, the tubing shall remain attached to both nozzles throughout the test period.
") |
- |
|
|
|
| 4.5 (When immersed in water for 5 min under an internal air pressure of 0.25 MPa or 250 kPa (2.5 bar), the increase in the outside diameter or the tubing shall not be more than 15 percent.) |
- |
|
|
|
| 4.9 (60 cm long tubing shall be subjected to a crushing force of 350 N applied on the middle of the tubing evenly over a length of 25 mm for 5 minutes, and 30 min after removal of the force it shall not show any deformation or collapse, nor shall it leak when subjected to an internal air pressure of 250 kPa) |
- |
|
|
|
| 4.12 ("When tested in accordance with the method
described in Annex F, the tubing shall not burn to either of the outer marks within the test period of 45 s") |
- |
|
|
|
|
- |
- - |
| 5369 |
MARQUIS TECHNOLOGIES PRIVATE LIMITED, NOIDA
| 8175126
| IS 302 : Part 1 (2008) |
Safety of household and similar electrical appliances: Part 1 general requirements (Sixth Revision) |
- |
54000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 7(Marking and instructions) |
- |
1000 |
|
- |
| 8.1.1(Protection against live parts in all positions) |
- |
1000 |
|
- |
| 8.1.2(Protection against live parts in openings) |
- |
2000 |
|
- |
| 8.1.3(Protection against live parts in visible glowing heating elements) |
- |
2000 |
|
- |
| 8.1.4(Protection against live parts against protective impedance) |
- |
2000 |
|
- |
| 9(Starting of motor operation test requirements and tests) |
- |
0 |
|
- |
| 10.1(Power input) |
- |
1000 |
|
- |
| 10.2(Current input) |
- |
1000 |
|
- |
| 11.1(General) |
- |
0 |
|
- |
| 11.2(General) |
- |
0 |
|
- |
| 11.3(Heating) |
- |
2000 |
|
- |
| 13.1(General) |
- |
0 |
|
- |
| 13.2(Leakage current at operating temperature) |
- |
2000 |
|
- |
| 13.3(Electric Strength at operating temperature) |
- |
2000 |
|
- |
| 14(Transient Over Voltages) |
- |
2000 |
|
- |
| 15.0(General) |
- |
0 |
|
- |
| 15.1(Ingress Protection test other than IPX0 (IP test)) |
- |
2000 |
|
- |
| 15.2(Spillage Test) |
- |
2000 |
|
- |
| 15.3(Humidity Test) |
- |
2000 |
|
- |
| 16.0(General) |
- |
0 |
|
- |
| 16.1(General) |
- |
0 |
|
- |
| 16.2(Leakage Current (after Clause 15)) |
- |
2000 |
|
- |
| 16.3(Electric Strength (after clause 15 and 16.2)) |
- |
2000 |
|
- |
| 17(Over Load Protection of Transformers and associated circuits) |
- |
2000 |
|
- |
| 18(Endurance Test requirements and tests) |
- |
2000 |
|
- |
| 19(Abnormal Operation) |
- |
2000 |
|
- |
| 20(Stability test) |
- |
2000 |
|
- |
| 21(Mechanical Strength Test) |
- |
2000 |
|
- |
| 22(Construction verification related test) |
- |
0 |
|
- |
| 23(General) |
- |
0 |
|
- |
| 24(Components) |
- |
0 |
|
- |
| 25(Supply connection and external flexible cords) |
- |
2000 |
|
- |
| 26(Terminals for external conductors) |
- |
2000 |
|
- |
| 27(Provision for earthing) |
- |
2000 |
|
- |
| 28(Screw test and connections) |
- |
2000 |
|
- |
| 29(clearance, creepage distances and solid insulation) |
- |
2000 |
|
- |
| 30.1(Ball pressure test) |
- |
2000 |
|
- |
| 30.2(Glow Wire Test) |
- |
2000 |
|
- |
| 30.2(Needle Flame Test) |
- |
2000 |
|
- |
| 31(Resistance to Rusting) |
- |
0 |
|
- |
| 32(Radiation Toxicity and Similar Hazards) |
- |
0 |
|
- |
| 4(General requirement) |
- |
0 |
|
- |
| 16(Leakage current and electric strength) |
- |
2000 |
|
- |
| 17(Overload protection of transformers and associated circuits) |
- |
2000 |
|
- |
| 18(Endurance) |
- |
2000 |
|
- |
| 8.1.5(Live parts of built-in appliances) |
- |
0 |
|
- |
| 11.4(Heating appliances) |
- |
0 |
|
- |
| 11.5(Motor-operated appliances) |
- |
0 |
|
- |
| 11.6(Combined appliances) |
- |
0 |
|
- |
| 11.7(Duration corresponding) |
- |
0 |
|
- |
| 11.8(Temperature rise) |
- |
0 |
|
- |
| 19.11.4.1(Electrostatic discharges) |
- |
0 |
|
- |
| 19.11.4.2(Radiated fields) |
- |
0 |
|
- |
| 19.11.4.3(Fast transient bursts) |
- |
0 |
|
- |
| 19.11.4.4(Surge immunity test) |
- |
0 |
|
- |
| 19.11.4.5(Immunity to conducted discharges) |
- |
0 |
|
- |
| 19.11.4.7(Harmonics) |
- |
0 |
|
- |
| 4(General Requirement) |
- |
0 |
|
- |
| 5(General conditions for tests) |
- |
0 |
|
- |
| 6(Classification- IS 302-1) |
- |
0 |
|
- |
| 19.11.4.6(Class 3 Voltage dips and interruptions) |
- |
0 |
|
- |
| 7(Marking and instructions) |
- |
0 |
|
- |
| 8.1.1(Protection against live parts in all positions) |
- |
0 |
|
- |
| 8.1.2(Protection against live parts in openings) |
- |
0 |
|
- |
| 8.1.3(Protection against live parts in visible glowing heating elements) |
- |
0 |
|
- |
| 8.1.4(Protection against live parts against protective impedance) |
- |
0 |
|
- |
| 9(Starting of motor operation test requirements and tests) |
- |
0 |
|
- |
| 10.1(Power input) |
- |
0 |
|
- |
| 10.2(Current input) |
- |
0 |
|
- |
| 11.1(General) |
- |
0 |
|
- |
| 11.2(General) |
- |
0 |
|
- |
| 11.3(Heating) |
- |
0 |
|
- |
| 13.1(General) |
- |
0 |
|
- |
| 13.2(Leakage current at operating temperature) |
- |
0 |
|
- |
| 13.3(Electric Strength at operating temperature) |
- |
0 |
|
- |
| 14(Transient Over Voltages) |
- |
0 |
|
- |
| 15.0(General) |
- |
0 |
|
- |
| 15.1(Ingress Protection test other than IPX0 (IP test)) |
- |
0 |
|
- |
| 15.2(Spillage Test) |
- |
0 |
|
- |
| 15.3(Humidity Test) |
- |
0 |
|
- |
| 16.0(General) |
- |
0 |
|
- |
| 16.1(General) |
- |
0 |
|
- |
| 16.2(Leakage Current (after Clause 15)) |
- |
0 |
|
- |
| 16.3(Electric Strength (after clause 15 and 16.2)) |
- |
0 |
|
- |
| 17(Over Load Protection of Transformers and associated circuits) |
- |
0 |
|
- |
| 18(Endurance Test requirements and tests) |
- |
0 |
|
- |
| 19(Abnormal Operation) |
- |
0 |
|
- |
| 20(Stability test) |
- |
0 |
|
- |
| 21(Mechanical Strength Test) |
- |
0 |
|
- |
| 22(Construction verification related test) |
- |
0 |
|
- |
| 23(General) |
- |
0 |
|
- |
| 24(Components) |
- |
0 |
|
- |
| 25(Supply connection and external flexible cords) |
- |
0 |
|
- |
| 26(Terminals for external conductors) |
- |
0 |
|
- |
| 27(Provision for earthing) |
- |
0 |
|
- |
| 28(Screw test and connections) |
- |
0 |
|
- |
| 29(clearance, creepage distances and solid insulation) |
- |
0 |
|
- |
| 30.1(Ball pressure test) |
- |
0 |
|
- |
| 30.2(Glow Wire Test) |
- |
0 |
|
- |
| 30.2(Needle Flame Test) |
- |
0 |
|
- |
| 31(Resistance to Rusting) |
- |
0 |
|
- |
| 32(Radiation Toxicity and Similar Hazards) |
- |
0 |
|
- |
| 4(General requirement) |
- |
0 |
|
- |
| 16(Leakage current and electric strength) |
- |
0 |
|
- |
| 17(Overload protection of transformers and associated circuits) |
- |
0 |
|
- |
| 18(Endurance) |
- |
0.01 |
|
- |
| 8.1.5(Live parts of built-in appliances) |
- |
0 |
|
- |
| 11.4(Heating appliances) |
- |
0 |
|
- |
| 11.5(Motor-operated appliances) |
- |
0 |
|
- |
| 11.6(Combined appliances) |
- |
0 |
|
- |
| 11.7(Duration corresponding) |
- |
0 |
|
- |
| 11.8(Temperature rise) |
- |
0 |
|
- |
| 19.11.4.1(Electrostatic discharges) |
- |
0 |
|
- |
| 19.11.4.2(Radiated fields) |
- |
0 |
|
- |
| 19.11.4.3(Fast transient bursts) |
- |
0 |
|
- |
| 19.11.4.4(Surge immunity test) |
- |
0 |
|
- |
| 19.11.4.5(Immunity to conducted discharges) |
- |
0 |
|
- |
| 19.11.4.7(Harmonics) |
- |
0 |
|
- |
| 4(General Requirement) |
- |
0 |
|
- |
| 5(General conditions for tests) |
- |
0 |
|
- |
| 6(Classification- IS 302-1) |
- |
0 |
|
- |
| 19.11.4.6(Class 3 Voltage dips and interruptions) |
- |
0 |
|
- |
| 7(Marking and instructions) |
- |
0 |
|
- |
| 8.1.1(Protection against live parts in all positions) |
- |
0 |
|
- |
| 8.1.2(Protection against live parts in openings) |
- |
0 |
|
- |
| 8.1.3(Protection against live parts in visible glowing heating elements) |
- |
0 |
|
- |
| 8.1.4(Protection against live parts against protective impedance) |
- |
0 |
|
- |
| 9(Starting of motor operation test requirements and tests) |
- |
0 |
|
- |
| 10.1(Power input) |
- |
0 |
|
- |
| 10.2(Current input) |
- |
0 |
|
- |
| 11.1(General) |
- |
0 |
|
- |
| 11.2(General) |
- |
0 |
|
- |
| 11.3(Heating) |
- |
0 |
|
- |
| 13.1(General) |
- |
0 |
|
- |
| 13.2(Leakage current at operating temperature) |
- |
0 |
|
- |
| 13.3(Electric Strength at operating temperature) |
- |
0 |
|
- |
| 14(Transient Over Voltages) |
- |
0 |
|
- |
| 15.0(General) |
- |
0 |
|
- |
| 15.1(Ingress Protection test other than IPX0 (IP test)) |
- |
0 |
|
- |
| 15.2(Spillage Test) |
- |
0 |
|
- |
| 15.3(Humidity Test) |
- |
0 |
|
- |
| 16.0(General) |
- |
0 |
|
- |
| 16.1(General) |
- |
0 |
|
- |
| 16.2(Leakage Current (after Clause 15)) |
- |
0 |
|
- |
| 16.3(Electric Strength (after clause 15 and 16.2)) |
- |
0 |
|
- |
| 17(Over Load Protection of Transformers and associated circuits) |
- |
0 |
|
- |
| 18(Endurance Test requirements and tests) |
- |
0 |
|
- |
| 19(Abnormal Operation) |
- |
0 |
|
- |
| 20(Stability test) |
- |
0 |
|
- |
| 21(Mechanical Strength Test) |
- |
0 |
|
- |
| 22(Construction verification related test) |
- |
0 |
|
- |
| 23(General) |
- |
0 |
|
- |
| 24(Components) |
- |
0 |
|
- |
| 25(Supply connection and external flexible cords) |
- |
0 |
|
- |
| 26(Terminals for external conductors) |
- |
0 |
|
- |
| 27(Provision for earthing) |
- |
0 |
|
- |
| 28(Screw test and connections) |
- |
0 |
|
- |
| 29(clearance, creepage distances and solid insulation) |
- |
0 |
|
- |
| 30.1(Ball pressure test) |
- |
0 |
|
- |
| 30.2(Glow Wire Test) |
- |
0 |
|
- |
| 30.2(Needle Flame Test) |
- |
0 |
|
- |
| 31(Resistance to Rusting) |
- |
0 |
|
- |
| 32(Radiation Toxicity and Similar Hazards) |
- |
0 |
|
- |
| 4(General requirement) |
- |
0 |
|
- |
| 16(Leakage current and electric strength) |
- |
0 |
|
- |
| 17(Overload protection of transformers and associated circuits) |
- |
0 |
|
- |
| 18(Endurance) |
- |
0 |
|
- |
| 8.1.5(Live parts of built-in appliances) |
- |
0 |
|
- |
| 11.4(Heating appliances) |
- |
0 |
|
- |
| 11.5(Motor-operated appliances) |
- |
0 |
|
- |
| 11.6(Combined appliances) |
- |
0 |
|
- |
| 11.7(Duration corresponding) |
- |
0 |
|
- |
| 11.8(Temperature rise) |
- |
0 |
|
- |
| 19.11.4.1(Electrostatic discharges) |
- |
0 |
|
- |
| 19.11.4.2(Radiated fields) |
- |
0 |
|
- |
| 19.11.4.3(Fast transient bursts) |
- |
0 |
|
- |
| 19.11.4.4(Surge immunity test) |
- |
0 |
|
- |
| 19.11.4.5(Immunity to conducted discharges) |
- |
0 |
|
- |
| 19.11.4.7(Harmonics) |
- |
0 |
|
- |
| 4(General Requirement) |
- |
0 |
|
- |
| 5(General conditions for tests) |
- |
0 |
|
- |
| 6(Classification- IS 302-1) |
- |
0 |
|
- |
| 19.11.4.6(Class 3 Voltage dips and interruptions) |
- |
0 |
|
- |
|
13 Dec, 2026 |
- Included w.e.f 19.05.2025
Exclusion: Cl 19.11.4.1-Cl 19.11.4.7(EMI/EMC)
"(1)Cooking ranges, hobs, ovens and similar appliances, (2)Commercial Dispensing Appliances and Vending Machines, (3) spin extractors
(For testing charges please refer relevant Part 2 standard in LIMS)" |
| 5370 |
KRISHNA DIGITAL MATERIAL TESTING LABORATORY LLP, BHOPAL
| 8168706
| IS 15658 (2021) |
Concrete Paving Blocks - Specification ( First Revision ) |
M30 TO M50 |
8500 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Clauses 7.1.2 & 9.1.2
(Visual Inspection) |
- |
100 |
|
0 |
| Clause 7.1.3
(Colour and Texture) |
- |
100 |
|
0 |
| Clause 6.3
(Bonding and Delamination between the layers of paver blocks) |
- |
100 |
|
0 |
| Clause 7.2, Table No. 2, SI No. (i)
(Width, W) |
- |
250 |
|
0 |
| Clause 7.2, Table No. 2, SI No. (i)
(Indivdual Width, W) |
- |
250 |
|
0 |
| Clause 7.2, Table No. 2, SI No. (ii)
(Length, L) |
- |
250 |
|
0 |
| Clause 7.2, Table No. 2, SI No. (ii)
(Indivdual Length, L) |
- |
250 |
|
0 |
| Clause 7.2, Table No. 2, SI No. (iii)
(Thickness, Th) |
- |
250 |
|
0 |
| Clause 7.2, Table No. 2, SI No. (iii)
(Indivdual Thickness, Th) |
- |
250 |
|
0 |
| Clause 7.2, Table No. 2, SI No. (iv)
(Aspect Ratio, L/Th) |
- |
150 |
|
0 |
| Clause 7.2, Table No. 2, SI No. (iv)
(Indivdual Aspect Ratio, L/Th) |
- |
150 |
|
0 |
| Clause 7.2 & 9.1.3, Table 2, SI No. (v)(Arris/chamfer, Width) |
- |
150 |
|
0 |
| Clause 7.2 & 9.1.3, Table 2, SI No. (v)(Indivdual Arris/chamfer, Width) |
- |
150 |
|
0 |
| Clause 7.2 & 9.1.3, Table 2, SI No. (vi)(Thickness of wearing Layer) |
- |
100 |
|
0 |
| Clause 7.2 & 9.1.3, Table 2, SI No. (vi)(Indivdual Thickness of wearing Layer) |
- |
100 |
|
0 |
| Clause 7.2 & 9.1.3, Table 2, SI No. (vii)(Plan Area (Asp)) |
- |
200 |
|
0 |
| Clause 7.2 & 9.1.3, Table 2, SI No. (vii)(Indivdual Plan Area (Asp)) |
- |
200 |
|
0 |
| Clause 7.2 & 9.1.3, Table 2, SI No. (viii)(Ratio of wearing face area and Plan area (Asw/Asp)) |
- |
200 |
|
0 |
| Clause 7.2 & 9.1.3, Table 2, SI No. (viii)(Indivdual Ratio of wearing face area and Plan area (Asw/Asp)) |
- |
150 |
|
00 |
| Clause 7.2 & 9.1.3, Table 2, SI No. (ix)(Deviation from squareness) |
- |
100 |
|
0 |
| Clause 7.3 & 9.1.4, Table 3, SI No. (i) a)( Indivdual Water absorption) |
- |
500 |
|
0 |
| Clause 7.3 & 9.1.4, Table 3, SI No. (i) b)(Water absorption (Average of three test specimens)) |
- |
500 |
|
0 |
| Clause 7.3 & 9.1.4, Table 3, SI No. (ii) a)(Indivdual Compressive strength (i)) |
- |
1000 |
|
0 |
| Clause 7.3 & 9.1.4, Table 3, SI No. (ii) b)(Compressive strength (Average of eight test specimens)) |
- |
1000 |
|
0 |
| Clause 7.3 & 9.1.4, Table 3, SI No. (iii) a) i)( Indivdual Dry Abrasion Resistance ) |
- |
1000 |
|
0 |
| Clause 7.3 & 9.1.4, Table 3, SI No. (iii) a) ii)(Dry Abrasion resistance (Average of three test specimens)) |
- |
800 |
|
0 |
| Clause 7.3 & 9.1.4, Table 3, SI No. (iii) b) i)( Indivdual Wet Abrasion Resistance ) |
- |
800 |
|
0 |
| Clause 7.3 & 9.1.4, Table 3, SI No. (iii) b) ii)(Wet Abrasion resistance (Average of three test specimens)) |
- |
750 |
|
0 |
| Clause 7.3 & 9.1.4, Table 3, SI No. (iv) a)(Indivdual Tensile splitting strength (i)) |
- |
1500 |
|
0 |
| Clause 7.3 & 9.1.4, Table 3, SI No. (iv) b)(Average Tensile splitting strength ) |
- |
1500 |
|
0 |
| Clause 7.3 & 9.1.4, Table 3, SI No. (v) a)(Indivdual Flexural strength (i)) |
- |
1200 |
|
0 |
| Clause 7.3 & 9.1.4, Table 3, SI No. (v) b)(Average Flexural strength ) |
- |
1200 |
|
0 |
| Clause 7.3, Annex F(Individual Failure Load per unit Length) |
- |
1500 |
|
0 |
| Clause 7.3, Annex F(Average Failure Load per unit Length) |
- |
1200 |
|
0 |
| Clause 7.3, Annex G(Individual Breaking Load) |
- |
1100 |
|
0 |
| Clause 7.3, Annex G(Average Breaking Load) |
- |
1100 |
|
0 |
|
19 Aug, 2027 |
- - |