| 5371 |
JBS TESTING SOLUTIONS PVT LTD (27), JALANDHAR
| 9164606
| IS 7898 (2024) |
Manually Operated Chaff Cutter - Specification and Test Code(Third Revision) |
- |
17500 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl-3.1(Material) |
- |
17500 |
|
- |
|
- |
- - |
| 5372 |
ACE TEST HOUSE PRIVATE LIMITED (8161906), NEW DELHI
| 8161906
| IS 15622 (2017) |
Pressed Ceramic Tiles - Specification (First Revision) |
Group BIa/BIb/BIIa/BIIb/BIII |
22500 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 6 table 5, i a (Length-IS 13630(pt-1)) |
- |
200 |
|
- |
| 6 table 5,i a (width-IS 13630(pt-1)) |
- |
200 |
|
- |
| 6 table 5, i b (Thickness- IS 13630(pt-1)) |
- |
200 |
|
- |
| 6 table 5, i c(Straigthness of side-IS 13630(pt-1)) |
- |
1000 |
|
- |
| 6 table 5, i d(Rectangularity-IS 13630(pt-1)) |
- |
1000 |
|
- |
| 6 table 5, i e(Surface flatness-IS 13630(pt-1)) |
- |
500 |
|
- |
| 6 table 5, i f(Surface quality-IS 13630(pt-1)) |
- |
200 |
|
- |
| 6 table 5, ii a(Water Absorption-IS 13630(pt-2)) |
- |
1000 |
|
- |
| 6 table 5, ii b(Module of rupture -IS 13630(pt-6)) |
- |
2500 |
|
- |
| 6 table 5, ii c(Bending Strength-IS 13630(pt-6)) |
- |
500 |
|
- |
| 6 table 5, ii d(Moisture Expension-IS 13630(pt-3)) |
- |
2000 |
|
- |
| 6 table 5, ii e(Scratch hardness of surface -IS 13630(pt-13)) |
- |
500 |
|
- |
| 6 table 5, ii f(Coefficient of linear tharmal expansion from ambient temperature to100°C-IS 13630(pt-4) ) |
- |
1500 |
|
- |
| 6 table 5, ii g(Thermal shock resistance IS 13630(pt-5)) |
- |
1500 |
|
- |
| 6 table 5, ii h(Impact resistance-IS 13630(pt-14)) |
- |
1000 |
|
- |
| 6 table 5, ii k(Crazing resistance-IS 13630(pt-9)) |
- |
4000 |
|
- |
| 6 table 5, ii m(resistance to surface abrasion of glazed Tilles) |
- |
1500 |
|
- |
| 6 table 5, iii a(Resistance to staining of glazed Tilles-IS 13630(pt-8)) |
- |
1200 |
|
- |
| 6 table 5, iii b(Resistance to household chemicals and swimming pool water cleansers agents containing hydrofluoric acid and its compound-IS 13630(pt-8)) |
- |
1000 |
|
- |
| 6 table 5, iii c(Resistance to acid and alkalis (with the exception ofhydrofluoric acid and its
compounds – Glazed tiles-IS 13630(pt-8)) |
- |
1000 |
|
- |
| 6 table 6, i a (Length-IS 13630(pt-1)) |
- |
200 |
|
- |
| 6 table 6, i a (width-IS 13630(pt-1)) |
- |
200 |
|
- |
| 6 table 6, i b (Thickness-IS 13630(pt-1)) |
- |
200 |
|
- |
| 6 table 6, i c(Straigthness of side-IS 13630(pt-1)) |
- |
1000 |
|
- |
| 6 table 6, i d(Rectangularity-IS 13630(pt-1)) |
- |
1000 |
|
- |
| 6 table 6, i e(Surface flatness-IS 13630(pt-1)) |
- |
500 |
|
- |
| 6 table 6, i f(Surface quality-IS 13630(pt-1)) |
- |
200 |
|
- |
| 6 table 6, ii a(Water Absorption-IS 13630(pt-2) ) |
- |
1000 |
|
- |
| 6 table 6, ii b(Module of rupture -IS 13630(pt-6)) |
- |
2500 |
|
- |
| 6 table 6, ii c(Bending Strength-IS 13630(pt-6)) |
- |
500 |
|
- |
| 6 table 6, ii d(Moisture Expension-IS 13630(pt-3)) |
- |
2000 |
|
- |
| 6 table 6, ii e(Scratch hardness of surface-IS 13630(pt-13) ) |
- |
500 |
|
- |
| 5 table 6, ii f(Resistance to surface abrasion of glazed Tilles) |
- |
1500 |
|
- |
| 6 table 6, ii g(Coefficient of linear tharmal expansion from ambient temperature to100°C-IS13630(pt-4) ) |
- |
1500 |
|
- |
| 6 table 6, ii h(Thermal shock resistance-IS13630(pt-5) ) |
- |
1500 |
|
- |
| 6 table 6, ii j(Crazing resistance-IS 13630(pt-9)) |
- |
4000 |
|
- |
| 6 table 6, ii k(Impact resistance-IS 13630(pt-14)) |
- |
1000 |
|
- |
| 6 table 6, ii n(Forst resistance-IS 13630(pt-10)) |
- |
2000 |
|
- |
| 6 table 6, ii p(Resistance to deep abrasion of unglazed tiles) |
- |
1500 |
|
- |
| 6 table 6, iii a(Resistance to staining of glazed Tilles) |
- |
1200 |
|
- |
| 6 table 6, iii b(Resistance to household chemicals and swimming pool water cleansers agents containing hydrofluoric acid and its compound) |
- |
1000 |
|
- |
| 6 table 6, iii c(Resistance to acid and alkalis (with the exception of hydrofluoric acid and its
compounds – Glazed tiles) |
- |
1000 |
|
- |
| 6 table 7, i a (Length-IS 13630(pt-1)) |
- |
200 |
|
- |
| 6 table 7, i a (width-IS 13630(pt-1)) |
- |
200 |
|
- |
| 6 table 7, i b (Thickness-IS 13630(pt-1)) |
- |
200 |
|
- |
| 6 table 7, i c(Straigthness of side-IS 13630(pt-1)) |
- |
1000 |
|
- |
| 6 table 7, i d(Rectangularity-IS 13630(pt-1)) |
- |
1000 |
|
- |
| 6 table 7, i e(Surface flatness-IS 13630(pt-1)) |
- |
500 |
|
- |
| 6 table 7, i f(Surface quality-IS 13630(pt-1)) |
- |
200 |
|
- |
| 6 table 7, ii a(Water Absorption-IS 13630(pt-2) ) |
- |
1000 |
|
- |
| 6 table 7, ii b(Module of rupture-IS 13630(pt-6) ) |
- |
2500 |
|
- |
| 6 table 7, ii c(Bending Strength-IS 13630(pt-6)) |
- |
500 |
|
- |
| 6 table 7, ii d(Moisture Expension-IS 13630(pt-3)) |
- |
2000 |
|
- |
| 6 table 7, ii e(Scratch hardness of surface-IS 13630(pt-13)) |
- |
500 |
|
- |
| 6 table 7, ii f(Resistance to surface abrasion of glazed Tilles) |
- |
1500 |
|
- |
| 6 table 7, ii g(Coefficient of linear tharmal expansion from ambient temperature to100°C-IS13630(pt-4) ) |
- |
1500 |
|
- |
| 6 table 7, ii h(Thermal shock resistance-IS13630(pt-5) ) |
- |
1500 |
|
- |
| 6 table 7, ii j(Crazing resistance-IS 13630(pt-9)) |
- |
4000 |
|
- |
| 6 table 7, ii k(Impact resistance-IS 13630(pt-14)) |
- |
1000 |
|
- |
| 6 table 7, ii n(Forst resistance-IS 13630(pt-10)) |
- |
2000 |
|
- |
| 6 table 7, ii p(Resistance to deep abrasion of unglazed tiles) |
- |
1500 |
|
- |
| 6 table 7, iii a(Resistance to staining of glazed Tilles) |
- |
1200 |
|
- |
| 6 table 7, iii b(Resistance to household chemicals and swimming pool water cleansers agents containing hydrofluoric acid and its compound) |
- |
1000 |
|
- |
| 6 table 7, iii c(Resistance to acid and alkalis (with the exception of hydrofluoric acid and its
compounds – Glazed tiles) |
- |
1000 |
|
- |
| 6 table 8, i a (Length-IS 13630(pt-1)) |
- |
200 |
|
- |
| 6 table 8, i a (width-IS 13630(pt-1)) |
- |
200 |
|
- |
| 6 table 8, i b (Thickness-IS 13630(pt-1)) |
- |
200 |
|
- |
| 6 table 8, i c(Straigthness of side-IS 13630(pt-1)) |
- |
1000 |
|
- |
| 6 table 8, i d(Rectangularity-IS 13630(pt-1)) |
- |
1000 |
|
- |
| 6 table 8, i e(Surface flatness-IS 13630(pt-1)) |
- |
500 |
|
- |
| 6 table 8, i f(Surface quality-IS 13630(pt-1)) |
- |
200 |
|
- |
| 6 table 8, ii a(Water Absorption-IS 13630(pt-6) ) |
- |
1000 |
|
- |
| 6 table 8, ii b(Module of rupture-IS 13630(pt-6) ) |
- |
2500 |
|
- |
| 6 table 8, ii c(Bending Strength-IS 13630(pt-6)) |
- |
500 |
|
- |
| 6 table 8, ii d(Moisture Expension-IS 13630(pt-3)) |
- |
2000 |
|
- |
| 6 table 8, ii e(Scratch hardness of surface-IS 13630(pt-13) ) |
- |
500 |
|
- |
| 6 table 8, ii f(Resistance to surface abrasion of glazed Tilles) |
- |
1500 |
|
- |
| 6 table 8, ii g(Coefficient of linear tharmal expansion from ambient temperature to100°C-IS 13630(pt-4) ) |
- |
1500 |
|
- |
| 6 table 8, ii h(Thermal shock resistance-IS 13630(pt-5) ) |
- |
1500 |
|
- |
| 6 table 8, ii j(Crazing resistance-IS 13630(pt-9)) |
- |
4000 |
|
- |
| 6 table 8, ii k(Impact resistance-IS 13630(pt-14)) |
- |
1000 |
|
- |
| 6 table 8, ii n(Forst resistance-IS 13630(pt-10)) |
- |
2000 |
|
- |
| 6 table 8, ii p(Resistance to deep abrasion of unglazed tiles) |
- |
1500 |
|
- |
| 6 table 8, ii q(Bulk Density-IS13630(pt-2)) |
- |
1000 |
|
- |
| 6 table 8, iii a(Resistance to staining of glazed Tilles) |
- |
1200 |
|
- |
| 6 table 8 iii b(Resistance to household chemicals and swimming pool water cleansers agents containing hydrofluoric acid and its compound) |
- |
1000 |
|
- |
| 6 table 8, iii c(Resistance to acid and alkalis (with the exception of hydrofluoric acid and its
compounds – Glazed tiles) |
- |
1000 |
|
- |
| 6 table 9, i a (Length-IS 13630(pt-1)) |
- |
200 |
|
- |
| 6 table 9, i a (width-IS 13630(pt-1)) |
- |
200 |
|
- |
| 6 table 9, i b (Thickness-IS 13630(pt-1)) |
- |
200 |
|
- |
| 6 table 9, i c(Straigthness of side-IS 13630(pt-1)) |
- |
1000 |
|
- |
| 6 table 9, i d(Rectangularity-IS 13630(pt-1)) |
- |
1000 |
|
- |
| 6 table 9, i e(Surface flatness-IS 13630(pt-1)) |
- |
500 |
|
- |
| 6 table 9, i f(Surface quality-IS 13630(pt-1)) |
- |
200 |
|
- |
| 6 table 9, ii a(Water Absorption-IS 13630(pt-6) ) |
- |
1000 |
|
- |
| 6 table 9, ii b(Module of rupture-IS 13630(pt-6) ) |
- |
2500 |
|
- |
| 6 table 9, ii c(Bending Strength-IS 13630(pt-6)) |
- |
500 |
|
- |
| 6 table 9, ii d(Moisture Expension-IS 13630(pt-3)) |
- |
2000 |
|
- |
| 6 table 9, ii e(Scratch hardness of surface-IS 13630(pt-13) ) |
- |
500 |
|
- |
| 6 table 9, ii f(Resistance to surface abrasion of glazed Tilles) |
- |
1500 |
|
- |
| 6 table 9, ii g(Coefficient of linear tharmal expansion from ambient temperature to100°C ) |
- |
1500 |
|
- |
| 6 table 9, ii h(Thermal shock resistance-IS 13630(pt-5)) |
- |
1500 |
|
- |
| 6 table 9, ii j(Crazing resistance-IS 13630(pt-9)) |
- |
4000 |
|
- |
| 6 table 9, ii k(Impact resistance-IS 13630(pt-14)) |
- |
1000 |
|
- |
| 6 table 9, ii n(Forst resistance-IS 13630(pt-10)) |
- |
2000 |
|
- |
| 6 table 9, ii p(Resistance to deep abrasion of unglazed tiles) |
- |
1500 |
|
- |
| 6 table 9, ii q(Bulk Density-) |
- |
1000 |
|
- |
| 6 table 9, iii a(Resistance to staining ) |
- |
1200 |
|
- |
| 6 table 9 iii b(Resistance to household chemicals and swimming pool water cleansers agents containing hydrofluoric acid and its compound) |
- |
1000 |
|
- |
| 6 table 9, iii c(Resistance to acid and alkalis (with the exception of hydrofluoric acid and its
compounds – Glazed tiles) |
- |
1000 |
|
- |
| 6.0, Table 5 - 9 & SI No. - 1E(3)(Warpage) |
- |
200 |
|
- |
| 6.0, Table 5 - 9 & SI No. - 1E(2)(Edge Curveture) |
- |
200 |
|
- |
| CLAUSE NO. 5.2(Shapes and Sizes) |
- |
200 |
|
- |
|
26 Aug, 2027 |
- - |
| 5373 |
HT Product Services Private Limited, Noida
| 8175006
| IS 1258 (2024) |
Bayonet lampholders (Fifth Revision) |
- |
40000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4(General requirements) |
- |
5000 |
|
- |
| 6(Standard ratings) |
- |
5000 |
|
- |
| 7(Classification) |
- |
5000 |
|
- |
| 8(Marking) |
- |
5000 |
|
- |
| 9(Dimensions) |
- |
5000 |
|
- |
| 10(Protection against electric shock) |
- |
5000 |
|
- |
| 11(Terminals) |
- |
5000 |
|
- |
| 12(Provision for earthing) |
- |
5000 |
|
- |
| 13(Construction) |
- |
5000 |
|
- |
| 14(Switched lampholders) |
- |
5000 |
|
- |
| 15(Moisture resistance, insulation resistance and electrical strength) |
- |
5000 |
|
- |
| 16(Mechanical strength) |
- |
5000 |
|
- |
| 17(Screws, current-carrying parts and connections) |
- |
5000 |
|
- |
| 18(Creepage distances and clearances) |
- |
5000 |
|
- |
| 19(General resistance to heat) |
- |
5000 |
|
- |
| 20(Resistance to heat, fire and tracking) |
- |
5000 |
|
- |
| 21(Resistance to excessive residual stresses (season cracking) and to rusting) |
- |
5000 |
|
- |
| Annex A(Season cracking/corrosion test) |
- |
5000 |
|
- |
| 12.4(Thermal tests) |
- |
5000 |
|
- |
| 9.1(Lampholder dimensions) |
- |
5000 |
|
- |
| 11.2(Terminals) |
- |
5000 |
|
- |
| 12.3(Provision for earthing) |
- |
5000 |
|
- |
| 13.1(Construction) |
- |
5000 |
|
- |
| 13.8(Construction) |
- |
5000 |
|
- |
| 14.4(Switched lampholders) |
- |
5000 |
|
- |
| 15.1(Moisture resistance, insulation resistance and electrical strength) |
- |
5000 |
|
- |
| 16.7(Mechanical strength) |
- |
5000 |
|
- |
| 16.8(Mechanical strength) |
- |
5000 |
|
- |
| 21.2(Resistance to excessive residual stresses (season cracking) and to rusting) |
- |
5000 |
|
- |
| 4(General requirements) |
- |
5000 |
|
- |
| 6(Standard ratings) |
- |
5000 |
|
- |
| 7(Classification) |
- |
5000 |
|
- |
| 8(Marking) |
- |
5000 |
|
- |
| 9(Dimensions) |
- |
5000 |
|
- |
| 10(Protection against electric shock) |
- |
5000 |
|
- |
| 11(Terminals) |
- |
5000 |
|
- |
| 12(Provision for earthing) |
- |
5000 |
|
- |
| 13(Construction) |
- |
5000 |
|
- |
| 14(Switched lampholders) |
- |
5000 |
|
- |
| 15(Moisture resistance, insulation resistance and electrical strength) |
- |
5000 |
|
- |
| 16(Mechanical strength) |
- |
5000 |
|
- |
| 17(Screws, current-carrying parts and connections) |
- |
5000 |
|
- |
| 18(Creepage distances and clearances) |
- |
5000 |
|
- |
| 19(General resistance to heat) |
- |
5000 |
|
- |
| 20(Resistance to heat, fire and tracking) |
- |
5000 |
|
- |
| 21(Resistance to excessive residual stresses (season cracking) and to rusting) |
- |
5000 |
|
- |
| Annex A(Season cracking/corrosion test) |
- |
5000 |
|
- |
| 12.4(Thermal tests) |
- |
5000 |
|
- |
| 9.1(Lampholder dimensions) |
- |
5000 |
|
- |
| 11.2(Terminals) |
- |
5000 |
|
- |
| 12.3(Provision for earthing) |
- |
5000 |
|
- |
| 13.1(Construction) |
- |
5000 |
|
- |
| 13.8(Construction) |
- |
5000 |
|
- |
| 14.4(Switched lampholders) |
- |
5000 |
|
- |
| 15.1(Moisture resistance, insulation resistance and electrical strength) |
- |
5000 |
|
- |
| 16.7(Mechanical strength) |
- |
5000 |
|
- |
| 16.8(Mechanical strength) |
- |
5000 |
|
- |
| 21.2(Resistance to excessive residual stresses (season cracking) and to rusting) |
- |
5000 |
|
- |
|
03 Dec, 2026 |
- Included w.e.f.18.08.2025 |
| 5374 |
SHRI KRISHNA TEST HOUSE PVT LTD (142)
| 8185606
| IS 18800 (2023) |
Stainless steel feeding bottle for infants -- Specification |
All |
30000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl.4.1(Carbon - IS 228 and its parts or any other intrumental/chemical methods) |
- |
30000 |
|
- |
| Cl.4.1(Silicon - IS 228 and its parts or any other intrumental/chemical methods) |
- |
30000 |
|
- |
| Cl.4.1(Manganese - IS 228 and its parts or any other intrumental/chemical methods) |
- |
30000 |
|
- |
| Cl.4.1(Nickel - IS 228 and its parts or any other intrumental/chemical methods) |
- |
30000 |
|
- |
| Cl.4.1(Chromium - IS 228 and its parts or any other intrumental/chemical methods) |
- |
30000 |
|
- |
| Cl.4.1(Sulphur - IS 228 and its parts or any other intrumental/chemical methods) |
- |
30000 |
|
- |
| Cl.4.1(Phosphorous - IS 228 and its parts or any other intrumental/chemical methods) |
- |
30000 |
|
- |
| Cl.4.1(Nitrogen - IS 228 and its parts or any other intrumental/chemical methods) |
- |
30000 |
|
- |
| Cl.4.1(Molybdenum - IS 228 and its parts or any other intrumental/chemical methods) |
- |
30000 |
|
- |
| Cl.4.1(Copper - IS 228 and its parts or any other intrumental/chemical methods) |
- |
30000 |
|
- |
| Cl.4.1(Other Elements - IS 228 and its parts or any other intrumental/chemical methods) |
- |
30000 |
|
- |
| 5.1.1(Description) |
- |
30000 |
|
- |
| 5.1.2(Manufacture, Workmanship, Finish and Appearance) |
- |
30000 |
|
- |
| 5.1.3(Wall Thickness) |
- |
30000 |
|
- |
| 5.1.4(Capacity) |
- |
30000 |
|
- |
| 5.2(Mechanical Requirements) |
- |
30000 |
|
- |
| 5.3.1(Leakage Test) |
- |
30000 |
|
- |
| 5.3.2(Drop Test) |
- |
30000 |
|
- |
| 5.3.3(Compressive Deformation Resistance) |
- |
30000 |
|
- |
| 5.3.4(Permanency of Pigments of Printed Container) |
- |
30000 |
|
- |
| 5.1.1(Description) |
- |
30000 |
|
- |
| 5.1.2(Manufacture, Workmanship, Finish and Appearance) |
- |
30000 |
|
- |
| 5.1.3(Wall Thickness) |
- |
30000 |
|
- |
| 5.1.4(Capacity) |
- |
30000 |
|
- |
| 5.2(Mechanical Requirements) |
- |
30000 |
|
- |
| 5.3.1(Leakage Test) |
- |
30000 |
|
- |
| 5.3.2(Drop Test) |
- |
30000 |
|
- |
| 5.3.3(Compressive Deformation Resistance) |
- |
30000 |
|
- |
| 5.3.4(Permanency of Pigments of Printed Container) |
- |
30000 |
|
- |
| Cl.5.3.4(Permanency of Pigments - Annex D of IS 18800) |
- |
30000 |
|
- |
| Cl.4.1(Carbon - IS 228 and its parts or any other intrumental/chemical methods) |
- |
30000 |
|
- |
| Cl.4.1(Silicon - IS 228 and its parts or any other intrumental/chemical methods) |
- |
30000 |
|
- |
| Cl.4.1(Manganese - IS 228 and its parts or any other intrumental/chemical methods) |
- |
30000 |
|
- |
| Cl.4.1(Nickel - IS 228 and its parts or any other intrumental/chemical methods) |
- |
30000 |
|
- |
| Cl.4.1(Chromium - IS 228 and its parts or any other intrumental/chemical methods) |
- |
30000 |
|
- |
| Cl.4.1(Sulphur - IS 228 and its parts or any other intrumental/chemical methods) |
- |
30000 |
|
- |
| Cl.4.1(Phosphorous - IS 228 and its parts or any other intrumental/chemical methods) |
- |
30000 |
|
- |
| Cl.4.1(Nitrogen - IS 228 and its parts or any other intrumental/chemical methods) |
- |
30000 |
|
- |
| Cl.4.1(Molybdenum - IS 228 and its parts or any other intrumental/chemical methods) |
- |
30000 |
|
- |
| Cl.4.1(Copper - IS 228 and its parts or any other intrumental/chemical methods) |
- |
30000 |
|
- |
| Cl.4.1(Other Elements - IS 228 and its parts or any other intrumental/chemical methods) |
- |
30000 |
|
- |
| 5.1.1(Description) |
- |
30000 |
|
- |
| 5.1.2(Manufacture, Workmanship, Finish and Appearance) |
- |
30000 |
|
- |
| 5.1.3(Wall Thickness) |
- |
30000 |
|
- |
| 5.1.4(Capacity) |
- |
30000 |
|
- |
| 5.2(Mechanical Requirements) |
- |
30000 |
|
- |
| 5.3.1(Leakage Test) |
- |
30000 |
|
- |
| 5.3.2(Drop Test) |
- |
30000 |
|
- |
| 5.3.3(Compressive Deformation Resistance) |
- |
30000 |
|
- |
| 5.3.4(Permanency of Pigments of Printed Container) |
- |
30000 |
|
- |
| 5.1.1(Description) |
- |
30000 |
|
- |
| 5.1.2(Manufacture, Workmanship, Finish and Appearance) |
- |
30000 |
|
- |
| 5.1.3(Wall Thickness) |
- |
30000 |
|
- |
| 5.1.4(Capacity) |
- |
30000 |
|
- |
| 5.2(Mechanical Requirements) |
- |
30000 |
|
- |
| 5.3.1(Leakage Test) |
- |
30000 |
|
- |
| 5.3.2(Drop Test) |
- |
30000 |
|
- |
| 5.3.3(Compressive Deformation Resistance) |
- |
30000 |
|
- |
| 5.3.4(Permanency of Pigments of Printed Container) |
- |
30000 |
|
- |
| Cl.5.3.4(Permanency of Pigments - Annex D of IS 18800) |
- |
30000 |
|
- |
|
13 May, 2028 |
- Included w.e.f 03.07.2025 |
| 5375 |
Arihant Analytical Laboratory Pvt. Ltd., Sonipat
| 9167906
| IS 18755 (2024) |
Tri-ply SS-AL-SS material used for manufacture of utensils and kitchen appliances Specification |
All Type |
12500 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl-4(Supply of material and designation) |
- |
12500 |
|
- |
| Cl-5(Manufacturer) |
- |
12500 |
|
- |
| Cl-6(Aluminium for use as matrix) |
- |
12500 |
|
- |
| Cl-6(Top-surface of the aluminium matrix) |
- |
12500 |
|
- |
| Cl-6(Bottom-surface of the aluminium matrix) |
- |
12500 |
|
- |
| Cl-7.1.1(Tensile properties) |
- |
12500 |
|
- |
| Cl-7.1.1(Apparent Yield Strength) |
- |
12500 |
|
- |
| Cl-7.1.1(Tensile Strength Mpa,) |
- |
12500 |
|
- |
| Cl-7.1.2(Test Specimen) |
- |
12500 |
|
- |
| Cl-7.1.3(Test Parameters) |
- |
12500 |
|
- |
| Cl-7.2.1(Bond strength of Tri-Ply) |
- |
12500 |
|
- |
| Cl-7.2.2(Sample Preparation and Test Specimen) |
- |
12500 |
|
- |
| Cl-7.2.3(Test Apparatus) |
- |
12500 |
|
- |
| Cl-7.2.4(Procedure) |
- |
12500 |
|
- |
| Cl-8.1(Sample of suitable size) |
- |
12500 |
|
- |
| Cl-8.2(specimen for peel strength) |
- |
12500 |
|
- |
| Cl-8.3, table-3(T-Peel Strength, N/mm, Min SS304 and Al 19500 interface) |
- |
12500 |
|
- |
| Cl-8.3, table-3(T-Peel Strength, N/mm, Min SS430 and Al 19500 interface) |
- |
12500 |
|
- |
| Cl-9.1(Thickness) |
- |
12500 |
|
- |
| Cl-9.2(Diameter) |
- |
12500 |
|
- |
| Cl-9.3(Flatness) |
- |
12500 |
|
- |
| Cl-10(surface finish) |
- |
12500 |
|
- |
| Cl-11(Workmanship, finish and appearance) |
- |
12500 |
|
- |
| Cl-14(Marking) |
- |
12500 |
|
- |
|
02 Jun, 2027 |
- Included w.e.f.29.07.2025 |
| 5376 |
Akshat Test Lab & Calibration Services, Ghaziabad
| 8186526
| IS 302 : Part 2 : Sec 15 (2009) |
Safety of household and similar electrical appliances: Part 2 particular requirements: Sec 15 appliances for heating liquids (First Revision) |
- |
40000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 6.0(Classification) |
- |
500 |
|
- |
| 7(Marking and instructions) |
- |
500 |
|
- |
| 8(Protection against live parts) |
- |
1000 |
|
- |
| 9(STARTING OF MOTOR-OPERATED APPLIANCES) |
- |
500 |
|
- |
| 10(POWER INPUT AND CURRENT) |
- |
2000 |
|
- |
| 11(HEATING) |
- |
2000 |
|
- |
| 13(LEAKAGE CURRENT AND ELECTRIC STRENGTH AT OPERATING TEMPERATURE) |
- |
1000 |
|
- |
| 14(TRANSIENT OVERVOLTAGES) |
- |
2000 |
|
- |
| 15(MOISTURE RESISTANCE) |
- |
2500 |
|
- |
| 16(LEAKAGE CURRENT AND ELECTRIC STRENGTH) |
- |
1500 |
|
- |
| 17(OVERLOAD PROTECTION OF TRANSFORMERS AND ASSOCIATED CIRCUITS) |
- |
2000 |
|
- |
| 18(ENDURANCE) |
- |
2500 |
|
- |
| 19(ABNORMAL OPERATION) |
- |
2500 |
|
- |
| 20(STABILITY AND MECHANICAL HAZARDS) |
- |
1000 |
|
- |
| 21(MECHANICAL STRENGTH) |
- |
2000 |
|
- |
| 22(CONSTRUCTION) |
- |
1000 |
|
- |
| 23(INTERNAL WIRING) |
- |
2000 |
|
- |
| 24(COMPONENTS) |
- |
1000 |
|
- |
| 25(SUPPLY CONNECTION AND EXTERNAL FLEXIBLE CORDS) |
- |
2000 |
|
- |
| 26(TERMINALS FOR EXTERNAL CONDUCTORS) |
- |
500 |
|
- |
| 27(PROVISION FOR EARTHING) |
- |
1000 |
|
- |
| 28(SCREWS AND CONNECTIONS) |
- |
1000 |
|
- |
| 29(CLEARANCES, CREEPAGE DISTANCES AND SOLID INSULATION) |
- |
1000 |
|
- |
| 30(RESISTANCE TO HEAT AND FIRE) |
- |
1000 |
|
- |
| 31(RESISTANCE TO RUSTING) |
- |
2000 |
|
- |
| 32(RADIATION, TOXICITY AND SIMILAR HAZARDS) |
- |
500 |
|
- |
| 22.16(Automatic cord reel) |
- |
500 |
|
- |
| 22.32(Oxygen bomb for rubber material) |
- |
0 |
|
- |
| 22.47(Water pressure inlet) |
- |
0 |
|
- |
| 22.106(Interlocks) |
- |
0 |
|
- |
| 22.3(Flexing test) |
- |
500 |
|
- |
| 24(Components) |
- |
1000 |
|
- |
| 4(General requirements) |
- |
500 |
|
- |
| 5(General Conditions of tests) |
- |
500 |
|
- |
| 6(Classification- IS 302-1) |
- |
0 |
|
- |
| 6(Classification- IS 302-1) |
- |
0 |
|
- |
| 7.1(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.1(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.1(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.1(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.1(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.1(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.1(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.1(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.1(Marking- IS 302-2-15) |
- |
0 |
|
- |
| 7.3(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.4(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.5(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.6(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.7(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.8(Marking- IS 302-1) |
- |
0 |
|
- |
| 6(Classification- IS 302-1) |
- |
0 |
|
- |
| 6(Classification- IS 302-1) |
- |
0 |
|
- |
| 7.1(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.1(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.1(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.1(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.1(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.1(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.1(Marking- IS 302-1) |
- |
0 |
|
- |
| Marking- IS 302-1(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.1(Marking- IS 302-2-15) |
- |
0 |
|
- |
| 7.3(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.4(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.1O(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.11(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.12(Marking- IS 302-2-15) |
- |
0 |
|
- |
| 7.12(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.12.3(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.12.5(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.12.6(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.13(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.14(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.15(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.101(Marking- IS 302-2-15) |
- |
0 |
|
- |
| 8(Protection Against Electric Shock, IS 302-1) |
- |
0 |
|
- |
| 10(Power Input and Current, IS 302-1) |
- |
0 |
|
- |
| 11(Heating, IS 302-1) |
- |
0 |
|
- |
| 11(Heating, IS 302-1) |
- |
0 |
|
- |
| 11(Heating, IS 302-1) |
- |
0 |
|
- |
| 11(Heating, IS 302-1) |
- |
0 |
|
- |
| 13(Electrical Insulation and Leakage Current at Operating Temperature: Leakage current, IS 302-1) |
- |
0 |
|
- |
| 13(Electrical Insulation and Leakage Current at Operating Temperature: High Voltage, IS 302-1) |
- |
0 |
|
- |
| 15.1(Moisture Resistance, IS 302-1) |
- |
0 |
|
- |
| 15.2(Spillage test as 15.2, IS 3.02-1 & 302-2-15) |
- |
0 |
|
- |
| 16(Leakage current as per Cl 16, IS 302-1) |
- |
0 |
|
- |
| 16(electric strength as per Cl 16, IS 302-1) |
- |
0 |
|
- |
| 17(Overload protection of Transformers and Associated Circuits, IS 302-1) |
- |
0 |
|
- |
| 19.13(Abnormal Operation as per Cl 19, IS 302-2-15) |
- |
0 |
|
- |
| 19.13(Abnormal Operation as per Cl 19, IS 302-1) |
- |
0 |
|
- |
| 19.13(Abnormal Operation as per Cl 19, IS 302-1) |
- |
0 |
|
- |
| 19.13(Abnormal Operation as per Cl 19, IS 302-1) |
- |
0 |
|
- |
| 20.1(Stability & Mechanical Hazards, IS 302-1) |
- |
0 |
|
- |
| 21.1(Mechanical Strength, IS 302-1) |
- |
0 |
|
- |
| 21.2(Mechanical Strength, IS 302-1) |
- |
0 |
|
- |
| 22.1(Construction, IS 302-1) |
- |
0 |
|
- |
| 22.7(Construction as per Cl 22.7, IS 3.02-2-15) |
- |
0 |
|
- |
| 22.107(Construction as per Cl 22.7, IS 3.02-2-15) |
- |
0 |
|
- |
| 22.108(Construction as per Cl 22.8, IS 3.02-2-15) |
- |
0 |
|
- |
| 23.1(Internal Wiring, IS 302-1) |
- |
0 |
|
- |
| 23.2(Internal Wiring, IS 302-1) |
- |
0 |
|
- |
| 23.4(Internal Wiring, IS 302-1) |
- |
0 |
|
- |
| 23.5(Internal Wiring, IS 302-1) |
- |
0 |
|
- |
| 23.6(Internal Wiring, IS 302-1) |
- |
0 |
|
- |
| 23.7(Internal Wiring, IS 302-1) |
- |
0 |
|
- |
| 23.8(Internal Wiring, IS 302-1) |
- |
0 |
|
- |
| 23.9(Internal Wiring, IS 302-1) |
- |
0 |
|
- |
| 23.1O(Internal Wiring, IS 302-1) |
- |
0 |
|
- |
| 25.1(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
- |
| 25.2(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
- |
| 25.5(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
- |
| 25.6(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
- |
| 25.8(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
- |
| 25.9(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
- |
| 25.1(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
- |
| 25.11(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
- |
| 25.12(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
- |
| 25.13(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
- |
| 25.14(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
- |
| 25.14(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
- |
| 25.15(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
- |
| 25.16(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
- |
| 25.17(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
- |
| 25.18(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
- |
| 25.19(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
- |
| 25.2(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
- |
| 25.21(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
- |
| 25.22(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
- |
| 26(Terminals for External Conductors, IS 302-1) |
- |
0 |
|
- |
| 27.1(Provision for Earthing, IS 302-1) |
- |
0 |
|
- |
| 27.2(Provision for Earthing, IS 302-1) |
- |
0 |
|
- |
| 27.3(Provision for Earthing, IS 302-1) |
- |
0 |
|
- |
| 27.4(Provision for Earthing, IS 302-1) |
- |
0 |
|
- |
| 27.5(Provision for Earthing, IS 302-1) |
- |
0 |
|
- |
| 28(Screws & Connections, IS 302-1) |
- |
0 |
|
- |
| 29.1(Clearances, Creepage distances and Solid Insulation, IS 302-1) |
- |
0 |
|
- |
| 29.2(Clearances, Creepage distances and Solid Insulation, IS 302-1) |
- |
0 |
|
- |
| 30.1(Resistance to Heat and Fire, IS 302-1) |
- |
0 |
|
- |
| 30.2(Resistance to Heat and Fire, IS 302-1) |
- |
0 |
|
- |
| 31(Resistance of Rusting, IS 302-1) |
- |
0 |
|
- |
| 7.5(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.6(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.7(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.8(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.9(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.12.1(Marking- IS 302-1) |
- |
0 |
|
40000 and 20% Discount for BIS |
|
- |
- Included w.e.f 16.07.2025
Exclusion: Cl 19.11.4.1-19.11.4.7(EMI/EMC), Cl 22.32 Oxygen bomb for rubber material |
| 5377 |
CIPET, Hyderabad
| 6111634
| IS 13487 (2024) |
Irrigation Equipment — Emitters — Specification |
Emitters |
3525 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl-5.1(Connections) |
- |
0 |
|
- |
| Cl-5.2(Emitter Ends) |
- |
0 |
|
- |
| Cl-5.3(Materials) |
- |
0 |
|
- |
| Cl-6.1(Test Specimens) |
- |
0 |
|
- |
| Cl-6.2.1(polyethylene pipe) |
- |
0 |
|
- |
| Cl-6.2.2("grease or chemicals
") |
- |
0 |
|
- |
| Cl-6.2.3(water temperature) |
- |
0 |
|
- |
| Cl-6.3(Accuracy or Measuring Devices) |
- |
0 |
|
- |
| Cl-7.1(Construction and Workmanship) |
- |
300.0 |
|
25% DISCOUNT FOR BIS |
| Cl-7.2(Flow Paths in Emitter) |
- |
300.0 |
|
25% DISCOUNT FOR BIS |
| Cl-7.3(Resistance to Hydrostatic Pressure) |
- |
1000.0 |
|
25% DISCOUNT FOR BIS |
| Cl-7.4(Emitter Pull-Out) |
- |
500.0 |
|
25% DISCOUNT FOR BIS |
| Cl-7.4.1(In-Line Emitters) |
- |
500.0 |
|
25% DISCOUNT FOR BIS |
| Cl-7.4.2(On-Line Emitters) |
- |
500.0 |
|
25% DISCOUNT FOR BIS |
| Cl-8.1.1(Uniformity of Emission Rate) |
- |
1000 |
|
25% DISCOUNT FOR BIS |
| Cl-8.1.2(Emission Rate as Function of Inlet Pressure) |
- |
1000.0 |
|
25% DISCOUNT FOR BIS |
| Cl-8.1.3(Determination of Emitter Exponent) |
- |
600.0 |
|
25% DISCOUNT FOR BIS |
| Cl-9(Marking) |
- |
500.0 |
|
25% DISCOUNT FOR BIS |
|
23 Feb, 2027 |
- Included w.e.f 28.07.2025 |
| 5378 |
JBS TESTING SOLUTIONS PVT LTD (27), JALANDHAR
| 9164606
| IS 3748 (2022) |
Tool Steels - Specification |
- |
12500 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 7.4(Shape, dimensions and tolerances) |
- |
4500 |
|
For dimensional and other qualitative test |
| 7.2(Chemical Composition) |
- |
5000 |
|
For chemical test |
| 7.2(Carbon) |
- |
5000 |
|
For chemical test |
| 7.2(Silicon) |
- |
5000 |
|
For chemical test |
| 7.2(Manganese) |
- |
4999.98 |
|
For chemical test |
| 7.2(Nickel) |
- |
5000 |
|
For chemical test |
| 7.2(Chromium) |
- |
5000 |
|
For chemical test |
| 7.2(Molybdenum) |
- |
5000 |
|
For chemical test |
| 7.2(Sulphur) |
- |
5000 |
|
For chemical test |
| 7.2(Phosphorus) |
- |
5000 |
|
For chemical test |
| 7.2(Nitrogen) |
- |
5000 |
|
For chemical test |
| 7.2(Copper) |
- |
5000 |
|
For chemical test |
| 7.2(Aluminium) |
- |
5000 |
|
For chemical test |
| 7.2(Titanium) |
- |
5000 |
|
For chemical test |
| 7.2(Niobium) |
- |
5000 |
|
For chemical test |
| 7.2(Cerium) |
- |
5000 |
|
For chemical test |
| 7.2(Tantalum) |
- |
5000 |
|
For chemical test |
| 7.2(Cobalt) |
- |
5000 |
|
For chemical test |
| 7.2(Tungsten) |
- |
5000 |
|
For chemical test |
| 7.2(Vanadium) |
- |
5000 |
|
For chemical test |
| 7.3(Surface Quality) |
- |
4499.98 |
|
For dimensional and other qualitative test |
| 7.4(Shapes, dimensions and tolerances) |
- |
4500 |
|
For dimensional and other qualitative test |
| 7.2(Hardness Test) |
- |
3000 |
|
For hardness test |
| Annex B.3(Verification of Minimum Hardness in Hardening Test) |
- |
3000 |
|
For hardness test |
| Annex B.7(Non-Destructive Test) |
- |
4500 |
|
For dimensional and other qualitative test |
| As per Clause 7.2, Table 2 to 9(Carbon) |
- |
5000 |
|
For chemical test |
| As per Clause 7.2, Table 2 to 9(Silicon) |
- |
5000 |
|
For chemical test |
| As per Clause 7.2, Table 2 to 9(Manganese) |
- |
5000 |
|
For chemical test |
| As per Clause 7.2, Table 2 to 9(Chromium) |
- |
5000 |
|
For chemical test |
| As per Clause 7.2, Table 2 to 9(Sulphur) |
- |
5000 |
|
For chemical test |
| As per Clause 7.2, Table 2 to 9(phosphorus) |
- |
5000 |
|
For chemical test |
| As per Clause 7.2, Table 2 to 9(Cobalt) |
- |
5000 |
|
For chemical test |
| As per Clause 7.2, Table 2 to 9(Molybdenum) |
- |
5000 |
|
For chemical test |
| As per Clause 7.2, Table 2 to 9(vanadium) |
- |
5000 |
|
For chemical test |
| As per Clause 7.2, Table 2 to 9(Tunsten) |
- |
5000 |
|
For chemical test |
| As per Clause 7.2, Table 2 to 9(Nickel) |
- |
5000 |
|
For chemical test |
| As per Clause 7.2, Table 2 to 9(Nitrogen) |
- |
5000 |
|
For chemical test |
| 4.1(Classification) |
- |
4500 |
|
For dimensional and other qualitative test |
| 4.2(Designation) |
- |
4500 |
|
For dimensional and other qualitative test |
| 6.2.1(General) |
- |
4500 |
|
For dimensional and other qualitative test |
| 6.2.2(Heat-treatment condition) |
- |
4500 |
|
For dimensional and other qualitative test |
| 6.2.3(Surface Condition) |
- |
4500 |
|
For dimensional and other qualitative test |
| 7.1(General requirements) |
- |
4500 |
|
For dimensional and other qualitative test |
| 7.2(Chemical composition and mechanical properties) |
- |
5000 |
|
For chemical test |
| 7.3(Surface quality) |
- |
4500 |
|
For dimensional and other qualitative test |
| 7.4(Shape, dimensions and tolerances) |
- |
4499.99 |
|
For dimensional and other qualitative test |
| 9(Marking) |
- |
4499.98 |
|
For dimensional and other qualitative test |
| 11.1(Product diameter or thickness ≥ 15 mm) |
- |
4500 |
|
For dimensional and other qualitative test |
| 11.2(Product diameter or thickness < 15 mm) |
- |
4500 |
|
For dimensional and other qualitative test |
|
- |
- Included w.e.f.30.06.2025 |
| 5379 |
BIS, Central Laboratory (CL)
| None
| IS 2556 : Part 2 (2024) |
Vitreous China Sanitary Appliances âSpecification Part 2 Specific Requirements of Washdown Water Closets (Sixth Revision) |
- |
- View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl-3 (GENERAL REQUIREMENTS) |
- |
|
|
|
| Cl-5 (DIMENSIONS AND TOLERANCES) |
- |
|
|
|
| Cl-6 (CONSTRUCTIONS) |
- |
|
|
|
| As per Clause 5 - Table 1 - i) (Height - A) |
- |
|
|
|
| As per Clause 5 - Table 1 - ii) (Depth of water seal, Min - H) |
- |
|
|
|
| As per Clause 5 - Table 1 - iii) (Width of water closet - J) |
- |
|
|
|
| As per Clause 5 - Table 1 - iv) (Distance from centre of seat bolt hole to front of water closet - K) |
- |
|
|
|
| As per Clause 5 - Table 1 - v) (Distance from centre of seat bolt
hole to inside face of flush rim at
back, Max - L) |
- |
|
|
|
| As per Clause 5 - Table 1 - vi) (Distance between a vertical line
from tip of back plate to inside
face of flush rim at back, Max - O) |
- |
|
|
|
| As per Clause 5 - Table 1 - vii) (Width of opening, Min - P) |
- |
|
|
|
| As per Clause 5 - Table 1 - viii) (Length of opening, Min - Q) |
- |
|
|
|
| As per Clause 5 - Table 1 - ix) (Overall length - S) |
- |
|
|
|
| As per Clause 5 - Table 1 - x) (Trap inlet depth, Min - T) |
- |
|
|
|
| As per Clause 5 - Table 1 - xi) (Water surface
Back to front - W1) |
- |
|
|
|
|
- |
- - |
| 5380 |
BIS, Central Laboratory (CL)
| None
| IS 251 (2024) |
SODA ASH, TECHNICAL â SPECIFICATION (fifth revision) |
Technical |
- View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4.1 ("Description
( IS 251 : 2024 )") |
- |
|
|
|
| 4.2 ("Bulk Density
( IS 251 : 2024 )") |
- |
|
|
|
| 4.3 ("Volatile Matter Content
( IS 251 : 2024 )") |
- |
|
|
|
| 4.4 ("Sieve Analysis of Dense Grade Soda Ash
( IS 251 : 2024 )") |
- |
|
|
|
| 4.4.1 ("Material retained on 1.70 mm IS Sieve
( IS 251 : 2024 )") |
- |
|
|
|
| 4.4.1 ("Material passing through 75 μm IS Sieve
( IS 251 : 2024 )") |
- |
|
|
|
| 4.5 Table 1 (i) ("Total alkalinity (as Na₂CO₃)
( IS 251 : 2024 )") |
- |
|
|
|
| 4.5 Table 1 (ii) ("Matter insoluble in water
( IS 251 : 2024 )") |
- |
|
|
|
| 4.5 Table 1 (iii) ("Sulphate (Na₂SO₄)
( IS 251 : 2024 )") |
- |
|
|
|
| 4.5 Table 1 (iv) ("Chloride (as NaCl)
( IS 251 : 2024 )") |
- |
|
|
|
| 4.5 Table 1 (5) ("Iron (as Fe₂O₃)
( IS 251 : 2024 )") |
- |
|
|
|
|
- |
- - |
| 5381 |
AADCO TESTING & RESEARCH LABORATORY PVT LTD (F28), GHAZIABAD
| 8141606
| IS 17505 : Part 1 (2021) |
Specification for Thermosetting Insulated Fire Survival Cables for Fixed Installation having Low Emission of Smoke and Corrosive Gases when Affected by Fire for Working Voltages upto and including 1100 Vac and 1500 Vdc |
ALL |
123780 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl. 7.3, Table 1 to 5 of IS 8130:2013 & IS:10810 (Part 5)-1984(Conductor Resistance Test) |
- |
2500 |
|
- |
| Cl. 7.1.2 of IS 8130 : 2013 & IS:10810 (Part 1)-1984(Annealing Test (for copper)) |
- |
1500 |
|
- |
| Cl. 7.1.1 of IS 8130:2013 & IS:10810 (Part 4)-1984(Persulphate Test for tinned copper) |
- |
2000 |
|
- |
| IS 191:2007 & IS 440(Copper purity test) |
- |
2000 |
|
- |
| Cl. 11,14,16, Table 4 and Table 6 of IS 17505 & IS:10810 (Part 6)-1984(Test for overall dimensions and thickness of insulation and sheath) |
- |
1500 |
|
- |
| Table 7 of IS 17505-1:2021, IS 3975:1999 & IS:10810 (Part 36)-1984(Diameter of armour Wire) |
- |
1000 |
|
- |
| Table 7 of IS 17505-1:2021, IS 3975:1999 & IS:10810 (Part 37)-1984(Tensile strength and elongation at break) |
- |
1000 |
|
- |
| Table 7 of IS 17505-1:2021, IS 3975:1999 & IS:10810 (Part 38)-1984(Torsion Test on galvanised steel wire for armouring) |
- |
500 |
|
- |
| Table 7 of IS 17505-1:2021, IS 3975:1999 & IS:10810 (Part 39)-1984(Winding Test for Formed Wires) |
- |
500 |
|
- |
| Table 7 of IS 17505-1:2021, IS 3975:1999 & IS:10810 (Part 40)-1984(Uniformity of Zinc coating on Round Steel Wires and Formed Steel Wires (Strips)) |
- |
750 |
|
- |
| Table 7 of IS 17505-1:2021, IS 3975:1999 & IS:10810 (Part 41)-1984(Mass of Zinc coating on Round Steel Wires and Formed Steel Wires (Strips)) |
- |
1500 |
|
- |
| Table 7 of IS 17505-1:2021, IS 3975:1999 & IS:10810 (Part 42)-1984(Resistivity test) |
- |
2500 |
|
- |
| Table 1 and Table 2 of IS 17505 -1: 2021, IS:10810 (Part 7)-1984 & IS:10810 (Part 11)-1984(Tensile Strength and elongation at break before and after ageing.) |
- |
3500 |
|
- |
| Cl 18.2 of IS 17505-1:2021 & IS:10810 (Part 45)-1984(High voltage test) |
- |
2500 |
|
- |
| Table 1 of IS 17505-1 :2021 & IS:10810 (Part 43)-1984(Insulation Resistance) |
- |
3000 |
|
- |
| Cl. 18.6 of IS 17505-1:2021 & IS:10810 (Part 58)-1998(Oxygen index) |
- |
3000 |
|
- |
| Cl. 18.7 of IS 17505-1:2021 & IS:10810 (Part 64)-2003(Temperature Index) |
- |
2000 |
|
- |
| Table-1 & Table-2 of IS 17505-1:2021 & IS:10810 (Part 11)-1984(Ageing in air oven.) |
- |
1500 |
|
- |
| Specification for thermosetting insulated fire survival cables for fixed installation having low emission of smoke and corrosive gases when affected by fire for working voltages upto and including 1100 V A.C. and 1500 V D.C(Hot deformation) |
- |
2000 |
|
- |
| Table-1 & Annex-F (F.1, F.2, F.3 F.4) of IS 17505-1 :2021(pH) |
- |
2000 |
|
- |
| Table-1 & Annex-F (F.1, F.2, F.3 F.4) of IS 17505-1 :2021(Conductivity) |
- |
2000 |
|
- |
| Table-1 & Annex-F (F.1, F.2, F.3 F.4) of IS 17505-1 :2021(HCl and HBr) |
- |
2000 |
|
- |
| Table-1 & Annex-F (F.1, F.2, F.3 F.4) of IS 17505-1 :2021(Presence of Fluorine / Fluorine Content (if required)) |
- |
2000 |
|
- |
| Table 1 of IS 17505-1: 2021 & IS:10810 (Part 21)-1984(Cold impact test) |
- |
1000 |
|
- |
| Table 1 & 2 of IS 17505-1: 2021 & IS:10810 (Part 30)-1984(Hot set test) |
- |
2500 |
|
- |
| Table 1 & 2 of IS 17505-1: 2021 & IS:10810 (Part 13)-1984(Ozone Resistance test) |
- |
7500 |
|
- |
| Cl 18.5.1 of IS 17505-1 :2021 & IS:10810 (Part 61)-1988(Flame test on single cable) |
- |
1000 |
|
- |
| Table 1 of IS 17505-1:2021 & IS:10810 (Part 12)-1984(Shrinkage test) |
- |
3000 |
|
- |
| Cl 7 & Annex-F (F.1, F.2, F.3 F.4) of IS 17505-1 :2021(pH) |
- |
2000 |
|
- |
| Cl 7 & Annex-F (F.1, F.2, F.3 F.4) of IS 17505-1 :2021(Conductivity) |
- |
2000 |
|
- |
| Cl 7 & Annex-F (F.1, F.2, F.3 F.4) of IS 17505-1 :2021(HCl and HBr) |
- |
2000 |
|
- |
| Cl 7 & Annex-F (F.1, F.2, F.3 F.4) of IS 17505-1 :2021(Presence of Fluorine / Fluorine Content (if required)) |
- |
3000 |
|
- |
| Tabel 1 and 2 of IS 17505-1:2021 & IS:10810 (Part 7)-1984(Tensile strength and elongation at break.) |
- |
2500 |
|
- |
| Tabel 1 and 2 of IS 17505-1:2021 & IS:10810 (Part 11)-1984(Ageing in air oven.) |
- |
3000 |
|
- |
| Cl 18.6 of IS 17505-1: 2021 & IS:10810 (Part 58)-1998(Oxygen Index.) |
- |
3000 |
|
- |
| Cl 18.8 of IS 17505-1:2021 & IS:10810 (Part 64)-2003(Temperature Index) |
- |
3000 |
|
- |
| Table 1 & 2 of IS 17505-1: 2021 & IS:10810 (Part 13)-1984(Ozone resistance test) |
- |
7500 |
|
- |
| Table 2 of IS 17505-1:2021 & IS:10810 (Part 15)-1984(Hot deformation) |
- |
1500 |
|
- |
| Cl 7 & Annex-F (F.1, F.2, F.3 F.4) of IS 17505-1 :2021(pH) |
- |
3000 |
|
- |
| Cl 7 & Annex-F (F.1, F.2, F.3 F.4) of IS 17505-1 :2021(Conductivity) |
- |
1250 |
|
- |
| Cl 7 & Annex-F (F.1, F.2, F.3 F.4) of IS 17505-1 :2021(HCl and HBr) |
- |
3500 |
|
- |
| Cl 7 & Annex-F (F.1, F.2, F.3 F.4) of IS 17505-1 :2021(Presence of Fluorine / Fluorine Content (if required)) |
- |
3000 |
|
- |
| Table 1 of IS 17505-1:2021 & IS:10810 (Part 12)-1984(Shrinkage test) |
- |
1000 |
|
- |
| Cl 18.2of IS 17505-1:2021 & IS:10810 (Part 45)-1984.(High Voltage test.) |
- |
2000 |
|
- |
| Table-2 of IS 17505-1:2021 & IS:10810 (Part 20)-1984(Cold bend test) |
- |
1000 |
|
- |
| Cl 18.5 of IS 17505-1:2021 & IS:10810 (Part 61)-1988(Flammability Test) |
- |
1500 |
|
- |
| Table-2 of IS 17505-1:2021 & IS:10810 (Part 21)-1984(Cold impact test) |
- |
1500 |
|
- |
| Cl 18.5of IS 17505-1:2021 & IS:10810 (Part 53)-1984(Flammability Test) |
- |
1000 |
|
- |
| Cl 18.9 of IS 17505-1:2021(Water immersion test ( effect of water on sheath of cable)) |
- |
3000 |
|
- |
| Cl 18.8 of IS 17505-1:2021& IS:10810 (Part 63)-1993(Smoke density test) |
- |
3000 |
|
- |
| Cl. 3.5, 18.4 & Annex-E of IS 17505-1:2021(Circuit integrity test under fire) |
- |
45000 |
|
- |
| Cl. 17.1 Table 9 (iv) m(Assessment of Halogen (HCl)) |
- |
1000 |
|
- |
| Cl. 17.1 Table 9 (iv) h(Water absorption (Gravimetric)) |
- |
3000 |
|
- |
| Cl. 17.1 Table 9 (vii) b(Flame test on bunched cable) |
- |
3000 |
|
- |
| Cl. 17.1 Table 9 (ix)(Abrasion resistance test) |
- |
3000 |
|
- |
| Cl. 17.1 Table 9 (iv) e(Heat Shock) |
- |
3000 |
|
- |
| Cl. 7.3, Table 1 to 5 of IS 8130:2013 & IS:10810 (Part 5)-1984(Conductor Resistance Test) |
- |
2000 |
|
- |
| Cl. 7.1.2 of IS 8130 : 2013 & IS:10810 (Part 1)-1984(Annealing Test (for copper)) |
- |
1000 |
|
- |
| Cl. 7.1.1 of IS 8130:2013 & IS:10810 (Part 4)-1984(Persulphate Test for tinned copper) |
- |
1500 |
|
- |
| IS 191:2007 & IS 440(Copper purity test) |
- |
2500 |
|
- |
| Cl. 11,14,16, Table 4 and Table 6 of IS 17505 & IS:10810 (Part 6)-1984(Test for overall dimensions and thickness of insulation and sheath) |
- |
500 |
|
- |
| Table 7 of IS 17505-1:2021, IS 3975:1999 & IS:10810 (Part 36)-1984(Diameter of armour Wire) |
- |
500 |
|
- |
| Table 7 of IS 17505-1:2021, IS 3975:1999 & IS:10810 (Part 37)-1984(Tensile strength and elongation at break) |
- |
750 |
|
- |
| Table 7 of IS 17505-1:2021, IS 3975:1999 & IS:10810 (Part 38)-1984(Torsion Test on galvanised steel wire for armouring) |
- |
500 |
|
- |
| Table 7 of IS 17505-1:2021, IS 3975:1999 & IS:10810 (Part 39)-1984(Winding Test for Formed Wires) |
- |
750 |
|
- |
| Table 7 of IS 17505-1:2021, IS 3975:1999 & IS:10810 (Part 40)-1984(Uniformity of Zinc coating on Round Steel Wires and Formed Steel Wires (Strips)) |
- |
500 |
|
- |
| Table 7 of IS 17505-1:2021, IS 3975:1999 & IS:10810 (Part 41)-1984(Mass of Zinc coating on Round Steel Wires and Formed Steel Wires (Strips)) |
- |
1500 |
|
- |
| Table 7 of IS 17505-1:2021, IS 3975:1999 & IS:10810 (Part 42)-1984(Resistivity test) |
- |
1500 |
|
- |
| Table 1 and Table 2 of IS 17505 -1: 2021, IS:10810 (Part 7)-1984 & IS:10810 (Part 11)-1984(Tensile Strength and elongation at break before and after ageing.) |
- |
750 |
|
- |
| Cl 18.2 of IS 17505-1:2021 & IS:10810 (Part 45)-1984(High voltage test) |
- |
3500 |
|
- |
| Table 1 of IS 17505-1 :2021 & IS:10810 (Part 43)-1984(Insulation Resistance) |
- |
1500 |
|
- |
| Cl. 18.6 of IS 17505-1:2021 & IS:10810 (Part 58)-1998(Oxygen index) |
- |
3000 |
|
- |
| Cl. 18.7 of IS 17505-1:2021 & IS:10810 (Part 64)-2003(Temperature Index) |
- |
3000 |
|
- |
| Table-1 & Table-2 of IS 17505-1:2021 & IS:10810 (Part 11)-1984(Ageing in air oven.) |
- |
1500 |
|
- |
| Specification for thermosetting insulated fire survival cables for fixed installation having low emission of smoke and corrosive gases when affected by fire for working voltages upto and including 1100 V A.C. and 1500 V D.C(Hot deformation) |
- |
500 |
|
- |
| Table-1 & Annex-F (F.1, F.2, F.3 F.4) of IS 17505-1 :2021(pH) |
- |
1000 |
|
- |
| Table-1 & Annex-F (F.1, F.2, F.3 F.4) of IS 17505-1 :2021(Conductivity) |
- |
1000 |
|
- |
| Table-1 & Annex-F (F.1, F.2, F.3 F.4) of IS 17505-1 :2021(HCl and HBr) |
- |
1500 |
|
- |
| Table-1 & Annex-F (F.1, F.2, F.3 F.4) of IS 17505-1 :2021(Presence of Fluorine / Fluorine Content (if required)) |
- |
750 |
|
- |
| Table 1 of IS 17505-1: 2021 & IS:10810 (Part 21)-1984(Cold impact test) |
- |
1500 |
|
- |
| Table 1 & 2 of IS 17505-1: 2021 & IS:10810 (Part 30)-1984(Hot set test) |
- |
2000 |
|
- |
| Table 1 & 2 of IS 17505-1: 2021 & IS:10810 (Part 13)-1984(Ozone Resistance test) |
- |
2500 |
|
- |
| Cl 18.5.1 of IS 17505-1 :2021 & IS:10810 (Part 61)-1988(Flame test on single cable) |
- |
1500 |
|
- |
| Table 1 of IS 17505-1:2021 & IS:10810 (Part 12)-1984(Shrinkage test) |
- |
2000 |
|
- |
| Cl 7 & Annex-F (F.1, F.2, F.3 F.4) of IS 17505-1 :2021(pH) |
- |
1000 |
|
- |
| Cl 7 & Annex-F (F.1, F.2, F.3 F.4) of IS 17505-1 :2021(Conductivity) |
- |
1000 |
|
- |
| Cl 7 & Annex-F (F.1, F.2, F.3 F.4) of IS 17505-1 :2021(HCl and HBr) |
- |
2000 |
|
- |
| Cl 7 & Annex-F (F.1, F.2, F.3 F.4) of IS 17505-1 :2021(Presence of Fluorine / Fluorine Content (if required)) |
- |
750 |
|
- |
| Tabel 1 and 2 of IS 17505-1:2021 & IS:10810 (Part 7)-1984(Tensile strength and elongation at break.) |
- |
1500 |
|
- |
| Tabel 1 and 2 of IS 17505-1:2021 & IS:10810 (Part 11)-1984(Ageing in air oven.) |
- |
1500 |
|
- |
| Cl 18.6 of IS 17505-1: 2021 & IS:10810 (Part 58)-1998(Oxygen Index.) |
- |
3000 |
|
- |
| Cl 18.8 of IS 17505-1:2021 & IS:10810 (Part 64)-2003(Temperature Index) |
- |
3000 |
|
- |
| Table 1 & 2 of IS 17505-1: 2021 & IS:10810 (Part 13)-1984(Ozone resistance test) |
- |
2000 |
|
- |
| Table 2 of IS 17505-1:2021 & IS:10810 (Part 15)-1984(Hot deformation) |
- |
750 |
|
- |
| Cl 7 & Annex-F (F.1, F.2, F.3 F.4) of IS 17505-1 :2021(pH) |
- |
1000 |
|
- |
| Cl 7 & Annex-F (F.1, F.2, F.3 F.4) of IS 17505-1 :2021(Conductivity) |
- |
1000 |
|
- |
| Cl 7 & Annex-F (F.1, F.2, F.3 F.4) of IS 17505-1 :2021(HCl and HBr) |
- |
2000 |
|
- |
| Cl 7 & Annex-F (F.1, F.2, F.3 F.4) of IS 17505-1 :2021(Presence of Fluorine / Fluorine Content (if required)) |
- |
750 |
|
- |
| Table 1 of IS 17505-1:2021 & IS:10810 (Part 12)-1984(Shrinkage test) |
- |
2000 |
|
- |
| Cl 18.2of IS 17505-1:2021 & IS:10810 (Part 45)-1984.(High Voltage test.) |
- |
3500 |
|
- |
| Table-2 of IS 17505-1:2021 & IS:10810 (Part 20)-1984(Cold bend test) |
- |
2000 |
|
- |
| Cl 18.5 of IS 17505-1:2021 & IS:10810 (Part 61)-1988(Flammability Test) |
- |
2000 |
|
- |
| Table-2 of IS 17505-1:2021 & IS:10810 (Part 21)-1984(Cold impact test) |
- |
2000 |
|
- |
| Cl 18.5of IS 17505-1:2021 & IS:10810 (Part 53)-1984(Flammability Test) |
- |
2000 |
|
- |
| Cl 18.9 of IS 17505-1:2021(Water immersion test ( effect of water on sheath of cable)) |
- |
1500 |
|
- |
| Cl 18.8 of IS 17505-1:2021& IS:10810 (Part 63)-1993(Smoke density test) |
- |
3500 |
|
- |
| Cl. 3.5, 18.4 & Annex-E of IS 17505-1:2021(Circuit integrity test under fire) |
- |
20000 |
|
- |
| Cl. 17.1 Table 9 (iv) m(Assessment of Halogen (HCl)) |
- |
2000 |
|
- |
| Cl. 17.1 Table 9 (iv) h(Water absorption (Gravimetric)) |
- |
2500 |
|
- |
| Cl. 17.1 Table 9 (vii) b(Flame test on bunched cable) |
- |
5000 |
|
- |
| Cl. 17.1 Table 9 (ix)(Abrasion resistance test) |
- |
1500 |
|
- |
| Cl. 17.1 Table 9 (iv) e(Heat Shock) |
- |
500 |
|
- |
| Cl. 7.3, Table 1 to 5 of IS 8130:2013 & IS:10810 (Part 5)-1984(Conductor Resistance Test) |
- |
2500 |
|
- |
| Cl. 7.1.2 of IS 8130 : 2013 & IS:10810 (Part 1)-1984(Annealing Test (for copper)) |
- |
500 |
|
- |
| Cl. 7.1.1 of IS 8130:2013 & IS:10810 (Part 4)-1984(Persulphate Test for tinned copper) |
- |
3000 |
|
- |
| IS 191:2007 & IS 440(Copper purity test) |
- |
3000 |
|
- |
| Cl. 11,14,16, Table 4 and Table 6 of IS 17505 & IS:10810 (Part 6)-1984(Test for overall dimensions and thickness of insulation and sheath) |
- |
750 |
|
- |
| Table 7 of IS 17505-1:2021, IS 3975:1999 & IS:10810 (Part 36)-1984(Diameter of armour Wire) |
- |
750 |
|
- |
| Table 7 of IS 17505-1:2021, IS 3975:1999 & IS:10810 (Part 37)-1984(Tensile strength and elongation at break) |
- |
1000 |
|
- |
| Table 7 of IS 17505-1:2021, IS 3975:1999 & IS:10810 (Part 38)-1984(Torsion Test on galvanised steel wire for armouring) |
- |
1500 |
|
- |
| Table 7 of IS 17505-1:2021, IS 3975:1999 & IS:10810 (Part 39)-1984(Winding Test for Formed Wires) |
- |
500 |
|
- |
| Table 7 of IS 17505-1:2021, IS 3975:1999 & IS:10810 (Part 40)-1984(Uniformity of Zinc coating on Round Steel Wires and Formed Steel Wires (Strips)) |
- |
1000 |
|
- |
| Table 7 of IS 17505-1:2021, IS 3975:1999 & IS:10810 (Part 41)-1984(Mass of Zinc coating on Round Steel Wires and Formed Steel Wires (Strips)) |
- |
1500 |
|
- |
| Table 7 of IS 17505-1:2021, IS 3975:1999 & IS:10810 (Part 42)-1984(Resistivity test) |
- |
2000 |
|
- |
| Table 1 and Table 2 of IS 17505 -1: 2021, IS:10810 (Part 7)-1984 & IS:10810 (Part 11)-1984(Tensile Strength and elongation at break before and after ageing.) |
- |
750 |
|
- |
| Cl 18.2 of IS 17505-1:2021 & IS:10810 (Part 45)-1984(High voltage test) |
- |
3000 |
|
- |
| Table 1 of IS 17505-1 :2021 & IS:10810 (Part 43)-1984(Insulation Resistance) |
- |
3500 |
|
- |
| Cl. 18.6 of IS 17505-1:2021 & IS:10810 (Part 58)-1998(Oxygen index) |
- |
3500 |
|
- |
| Cl. 18.7 of IS 17505-1:2021 & IS:10810 (Part 64)-2003(Temperature Index) |
- |
3000 |
|
- |
| Table-1 & Table-2 of IS 17505-1:2021 & IS:10810 (Part 11)-1984(Ageing in air oven.) |
- |
1500 |
|
- |
| Specification for thermosetting insulated fire survival cables for fixed installation having low emission of smoke and corrosive gases when affected by fire for working voltages upto and including 1100 V A.C. and 1500 V D.C(Hot deformation) |
- |
500 |
|
- |
| Table-1 & Annex-F (F.1, F.2, F.3 F.4) of IS 17505-1 :2021(pH) |
- |
750 |
|
- |
| Table-1 & Annex-F (F.1, F.2, F.3 F.4) of IS 17505-1 :2021(Conductivity) |
- |
750 |
|
- |
| Table-1 & Annex-F (F.1, F.2, F.3 F.4) of IS 17505-1 :2021(HCl and HBr) |
- |
2000 |
|
- |
| Table-1 & Annex-F (F.1, F.2, F.3 F.4) of IS 17505-1 :2021(Presence of Fluorine / Fluorine Content (if required)) |
- |
2000 |
|
- |
| Table 1 of IS 17505-1: 2021 & IS:10810 (Part 21)-1984(Cold impact test) |
- |
1500 |
|
- |
| Table 1 & 2 of IS 17505-1: 2021 & IS:10810 (Part 30)-1984(Hot set test) |
- |
2500 |
|
- |
| Table 1 & 2 of IS 17505-1: 2021 & IS:10810 (Part 13)-1984(Ozone Resistance test) |
- |
3000 |
|
- |
| Cl 18.5.1 of IS 17505-1 :2021 & IS:10810 (Part 61)-1988(Flame test on single cable) |
- |
1500 |
|
- |
| Table 1 of IS 17505-1:2021 & IS:10810 (Part 12)-1984(Shrinkage test) |
- |
1000 |
|
- |
| Cl 7 & Annex-F (F.1, F.2, F.3 F.4) of IS 17505-1 :2021(pH) |
- |
1500 |
|
- |
| Cl 7 & Annex-F (F.1, F.2, F.3 F.4) of IS 17505-1 :2021(Conductivity) |
- |
1500 |
|
- |
| Cl 7 & Annex-F (F.1, F.2, F.3 F.4) of IS 17505-1 :2021(HCl and HBr) |
- |
2500 |
|
- |
| Cl 7 & Annex-F (F.1, F.2, F.3 F.4) of IS 17505-1 :2021(Presence of Fluorine / Fluorine Content (if required)) |
- |
2000 |
|
- |
| Tabel 1 and 2 of IS 17505-1:2021 & IS:10810 (Part 7)-1984(Tensile strength and elongation at break.) |
- |
1000 |
|
- |
| Tabel 1 and 2 of IS 17505-1:2021 & IS:10810 (Part 11)-1984(Ageing in air oven.) |
- |
1500 |
|
- |
| Cl 18.6 of IS 17505-1: 2021 & IS:10810 (Part 58)-1998(Oxygen Index.) |
- |
3500 |
|
- |
| Cl 18.8 of IS 17505-1:2021 & IS:10810 (Part 64)-2003(Temperature Index) |
- |
3000 |
|
- |
| Table 1 & 2 of IS 17505-1: 2021 & IS:10810 (Part 13)-1984(Ozone resistance test) |
- |
3500 |
|
- |
| Table 2 of IS 17505-1:2021 & IS:10810 (Part 15)-1984(Hot deformation) |
- |
1500 |
|
- |
| Cl 7 & Annex-F (F.1, F.2, F.3 F.4) of IS 17505-1 :2021(pH) |
- |
1500 |
|
- |
| Cl 7 & Annex-F (F.1, F.2, F.3 F.4) of IS 17505-1 :2021(Conductivity) |
- |
1500 |
|
- |
| Cl 7 & Annex-F (F.1, F.2, F.3 F.4) of IS 17505-1 :2021(HCl and HBr) |
- |
2500 |
|
- |
| Cl 7 & Annex-F (F.1, F.2, F.3 F.4) of IS 17505-1 :2021(Presence of Fluorine / Fluorine Content (if required)) |
- |
2000 |
|
- |
| Table 1 of IS 17505-1:2021 & IS:10810 (Part 12)-1984(Shrinkage test) |
- |
750 |
|
- |
| Cl 18.2of IS 17505-1:2021 & IS:10810 (Part 45)-1984.(High Voltage test.) |
- |
3000 |
|
- |
| Table-2 of IS 17505-1:2021 & IS:10810 (Part 20)-1984(Cold bend test) |
- |
1500 |
|
- |
| Cl 18.5 of IS 17505-1:2021 & IS:10810 (Part 61)-1988(Flammability Test) |
- |
1500 |
|
- |
| Table-2 of IS 17505-1:2021 & IS:10810 (Part 21)-1984(Cold impact test) |
- |
1500 |
|
- |
| Cl 18.5of IS 17505-1:2021 & IS:10810 (Part 53)-1984(Flammability Test) |
- |
1500 |
|
- |
| Cl 18.9 of IS 17505-1:2021(Water immersion test ( effect of water on sheath of cable)) |
- |
3000 |
|
- |
| Cl 18.8 of IS 17505-1:2021& IS:10810 (Part 63)-1993(Smoke density test) |
- |
3000 |
|
- |
| Cl. 3.5, 18.4 & Annex-E of IS 17505-1:2021(Circuit integrity test under fire) |
- |
45000 |
|
- |
| Cl. 17.1 Table 9 (iv) m(Assessment of Halogen (HCl)) |
- |
2000 |
|
- |
| Cl. 17.1 Table 9 (iv) h(Water absorption (Gravimetric)) |
- |
3500 |
|
- |
| Cl. 17.1 Table 9 (vii) b(Flame test on bunched cable) |
- |
5500 |
|
- |
| Cl. 17.1 Table 9 (ix)(Abrasion resistance test) |
- |
2000 |
|
- |
| Cl. 17.1 Table 9 (iv) e(Heat Shock) |
- |
500 |
|
- |
| Cl. 7.3, Table 1 to 5 of IS 8130:2013 & IS:10810 (Part 5)-1984(Conductor Resistance Test) |
- |
3000 |
|
- |
| Cl. 7.1.2 of IS 8130 : 2013 & IS:10810 (Part 1)-1984(Annealing Test (for copper)) |
- |
500 |
|
- |
| Cl. 7.1.1 of IS 8130:2013 & IS:10810 (Part 4)-1984(Persulphate Test for tinned copper) |
- |
2500 |
|
- |
| IS 191:2007 & IS 440(Copper purity test) |
- |
22500 |
|
- |
| Cl. 11,14,16, Table 4 and Table 6 of IS 17505 & IS:10810 (Part 6)-1984(Test for overall dimensions and thickness of insulation and sheath) |
- |
750 |
|
- |
| Table 7 of IS 17505-1:2021, IS 3975:1999 & IS:10810 (Part 36)-1984(Diameter of armour Wire) |
- |
750 |
|
- |
| Table 7 of IS 17505-1:2021, IS 3975:1999 & IS:10810 (Part 37)-1984(Tensile strength and elongation at break) |
- |
1500 |
|
- |
| Table 7 of IS 17505-1:2021, IS 3975:1999 & IS:10810 (Part 38)-1984(Torsion Test on galvanised steel wire for armouring) |
- |
1500 |
|
- |
| Table 7 of IS 17505-1:2021, IS 3975:1999 & IS:10810 (Part 39)-1984(Winding Test for Formed Wires) |
- |
1000 |
|
- |
| Table 7 of IS 17505-1:2021, IS 3975:1999 & IS:10810 (Part 40)-1984(Uniformity of Zinc coating on Round Steel Wires and Formed Steel Wires (Strips)) |
- |
1500 |
|
- |
| Table 7 of IS 17505-1:2021, IS 3975:1999 & IS:10810 (Part 41)-1984(Mass of Zinc coating on Round Steel Wires and Formed Steel Wires (Strips)) |
- |
1500 |
|
- |
| Table 7 of IS 17505-1:2021, IS 3975:1999 & IS:10810 (Part 42)-1984(Resistivity test) |
- |
2000 |
|
- |
| Table 1 and Table 2 of IS 17505 -1: 2021, IS:10810 (Part 7)-1984 & IS:10810 (Part 11)-1984(Tensile Strength and elongation at break before and after ageing.) |
- |
1500 |
|
- |
| Cl 18.2 of IS 17505-1:2021 & IS:10810 (Part 45)-1984(High voltage test) |
- |
3500 |
|
- |
| Table 1 of IS 17505-1 :2021 & IS:10810 (Part 43)-1984(Insulation Resistance) |
- |
3500 |
|
- |
| Cl. 18.6 of IS 17505-1:2021 & IS:10810 (Part 58)-1998(Oxygen index) |
- |
3500 |
|
- |
| Cl. 18.7 of IS 17505-1:2021 & IS:10810 (Part 64)-2003(Temperature Index) |
- |
3500 |
|
- |
| Table-1 & Table-2 of IS 17505-1:2021 & IS:10810 (Part 11)-1984(Ageing in air oven.) |
- |
3000 |
|
- |
| Specification for thermosetting insulated fire survival cables for fixed installation having low emission of smoke and corrosive gases when affected by fire for working voltages upto and including 1100 V A.C. and 1500 V D.C(Hot deformation) |
- |
500 |
|
- |
| Table-1 & Annex-F (F.1, F.2, F.3 F.4) of IS 17505-1 :2021(pH) |
- |
2500 |
|
- |
| Table-1 & Annex-F (F.1, F.2, F.3 F.4) of IS 17505-1 :2021(Conductivity) |
- |
2500 |
|
- |
| Table-1 & Annex-F (F.1, F.2, F.3 F.4) of IS 17505-1 :2021(HCl and HBr) |
- |
2500 |
|
- |
| Table-1 & Annex-F (F.1, F.2, F.3 F.4) of IS 17505-1 :2021(Presence of Fluorine / Fluorine Content (if required)) |
- |
2000 |
|
- |
| Table 1 of IS 17505-1: 2021 & IS:10810 (Part 21)-1984(Cold impact test) |
- |
2000 |
|
- |
| Table 1 & 2 of IS 17505-1: 2021 & IS:10810 (Part 30)-1984(Hot set test) |
- |
2000 |
|
- |
| Table 1 & 2 of IS 17505-1: 2021 & IS:10810 (Part 13)-1984(Ozone Resistance test) |
- |
3500 |
|
- |
| Cl 18.5.1 of IS 17505-1 :2021 & IS:10810 (Part 61)-1988(Flame test on single cable) |
- |
1500 |
|
- |
| Table 1 of IS 17505-1:2021 & IS:10810 (Part 12)-1984(Shrinkage test) |
- |
1000 |
|
- |
| Cl 7 & Annex-F (F.1, F.2, F.3 F.4) of IS 17505-1 :2021(pH) |
- |
2500 |
|
- |
| Cl 7 & Annex-F (F.1, F.2, F.3 F.4) of IS 17505-1 :2021(Conductivity) |
- |
2500 |
|
- |
| Cl 7 & Annex-F (F.1, F.2, F.3 F.4) of IS 17505-1 :2021(HCl and HBr) |
- |
2500 |
|
- |
| Cl 7 & Annex-F (F.1, F.2, F.3 F.4) of IS 17505-1 :2021(Presence of Fluorine / Fluorine Content (if required)) |
- |
2000 |
|
- |
| Tabel 1 and 2 of IS 17505-1:2021 & IS:10810 (Part 7)-1984(Tensile strength and elongation at break.) |
- |
1500 |
|
- |
| Tabel 1 and 2 of IS 17505-1:2021 & IS:10810 (Part 11)-1984(Ageing in air oven.) |
- |
2000 |
|
- |
| Cl 18.6 of IS 17505-1: 2021 & IS:10810 (Part 58)-1998(Oxygen Index.) |
- |
3500 |
|
- |
| Cl 18.8 of IS 17505-1:2021 & IS:10810 (Part 64)-2003(Temperature Index) |
- |
3500 |
|
- |
| Table 1 & 2 of IS 17505-1: 2021 & IS:10810 (Part 13)-1984(Ozone resistance test) |
- |
3500 |
|
- |
| Table 2 of IS 17505-1:2021 & IS:10810 (Part 15)-1984(Hot deformation) |
- |
2000 |
|
- |
| Cl 7 & Annex-F (F.1, F.2, F.3 F.4) of IS 17505-1 :2021(pH) |
- |
2500 |
|
- |
| Cl 7 & Annex-F (F.1, F.2, F.3 F.4) of IS 17505-1 :2021(Conductivity) |
- |
2500 |
|
- |
| Cl 7 & Annex-F (F.1, F.2, F.3 F.4) of IS 17505-1 :2021(HCl and HBr) |
- |
2500 |
|
- |
| Cl 7 & Annex-F (F.1, F.2, F.3 F.4) of IS 17505-1 :2021(Presence of Fluorine / Fluorine Content (if required)) |
- |
2000 |
|
- |
| Table 1 of IS 17505-1:2021 & IS:10810 (Part 12)-1984(Shrinkage test) |
- |
1500 |
|
- |
| Cl 18.2of IS 17505-1:2021 & IS:10810 (Part 45)-1984.(High Voltage test.) |
- |
3500 |
|
- |
| Table-2 of IS 17505-1:2021 & IS:10810 (Part 20)-1984(Cold bend test) |
- |
1500 |
|
- |
| Cl 18.5 of IS 17505-1:2021 & IS:10810 (Part 61)-1988(Flammability Test) |
- |
1500 |
|
- |
| Table-2 of IS 17505-1:2021 & IS:10810 (Part 21)-1984(Cold impact test) |
- |
1500 |
|
- |
| Cl 18.5of IS 17505-1:2021 & IS:10810 (Part 53)-1984(Flammability Test) |
- |
2000 |
|
- |
| Cl 18.9 of IS 17505-1:2021(Water immersion test ( effect of water on sheath of cable)) |
- |
3500 |
|
- |
| Cl 18.8 of IS 17505-1:2021& IS:10810 (Part 63)-1993(Smoke density test) |
- |
3500 |
|
- |
| Cl. 3.5, 18.4 & Annex-E of IS 17505-1:2021(Circuit integrity test under fire) |
- |
30000 |
|
- |
| Cl. 17.1 Table 9 (iv) m(Assessment of Halogen (HCl)) |
- |
2500 |
|
- |
| Cl. 17.1 Table 9 (iv) h(Water absorption (Gravimetric)) |
- |
3500 |
|
- |
| Cl. 17.1 Table 9 (vii) b(Flame test on bunched cable) |
- |
5500 |
|
- |
| Cl. 17.1 Table 9 (ix)(Abrasion resistance test) |
- |
2500 |
|
- |
| Cl. 17.1 Table 9 (iv) e(Heat Shock) |
- |
1500 |
|
- |
|
26 Jul, 2027 |
- Included w.e.f. 01.09.2025 |
| 5382 |
Samridhi Test House Pvt. Ltd.
| 8184706
| IS 2553 : Part 2 (2019) |
Safety glass - Specification: Part 2 for road transport (First Revision) |
Safety glass - Specification: Part 2 for road transport |
15000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 5.1.1(Light Transmittance) |
- |
4900 |
|
Toughened Glass for panes: - 11,000/-
Laminated safety glass for panes: - 75,000/-
Laminated safety glass for windscreen: - 87,000/-
Toughened glass for windscreen: - 15,000/-
Plastic glazing: - 139,000/- |
| 5.1.1(Light Transmittance) |
- |
4700 |
|
Toughened Glass for panes: - 11,000/-
Laminated safety glass for panes: - 75,000/-
Laminated safety glass for windscreen: - 87,000/-
Toughened glass for windscreen: - 15,000/-
Plastic glazing: - 139,000/- |
| 5.1.2.1(Resistance to Abrasion) |
- |
7000 |
|
Toughened Glass for panes: - 11,000/-
Laminated safety glass for panes: - 75,000/-
Laminated safety glass for windscreen: - 87,000/-
Toughened glass for windscreen: - 15,000/-
Plastic glazing: - 139,000/- |
| 5.1.2.2(Resistance to Abrasion) |
- |
7000 |
|
Toughened Glass for panes: - 11,000/-
Laminated safety glass for panes: - 75,000/-
Laminated safety glass for windscreen: - 87,000/-
Toughened glass for windscreen: - 15,000/-
Plastic glazing: - 139,000/- |
| 5.1.2.3.1(Resistance to Abrasion) |
- |
1800 |
|
Toughened Glass for panes: - 11,000/-
Laminated safety glass for panes: - 75,000/-
Laminated safety glass for windscreen: - 87,000/-
Toughened glass for windscreen: - 15,000/-
Plastic glazing: - 139,000/- |
| 5.1.2.3.1(Resistance to Abrasion) |
- |
7500 |
|
Toughened Glass for panes: - 11,000/-
Laminated safety glass for panes: - 75,000/-
Laminated safety glass for windscreen: - 87,000/-
Toughened glass for windscreen: - 15,000/-
Plastic glazing: - 139,000/- |
| 5.1.2.3.2(Resistance to Abrasion) |
- |
7500 |
|
Toughened Glass for panes: - 11,000/-
Laminated safety glass for panes: - 75,000/-
Laminated safety glass for windscreen: - 87,000/-
Toughened glass for windscreen: - 15,000/-
Plastic glazing: - 139,000/- |
| 5.1.2.3.2(Resistance to Abrasion) |
- |
7000 |
|
Toughened Glass for panes: - 11,000/-
Laminated safety glass for panes: - 75,000/-
Laminated safety glass for windscreen: - 87,000/-
Toughened glass for windscreen: - 15,000/-
Plastic glazing: - 139,000/- |
| 5.2.1(Resistance to Temperature Changes) |
- |
3400 |
|
Toughened Glass for panes: - 11,000/-
Laminated safety glass for panes: - 75,000/-
Laminated safety glass for windscreen: - 87,000/-
Toughened glass for windscreen: - 15,000/-
Plastic glazing: - 139,000/- |
| 5.2.2(a) Resistance to Fire) |
- |
7000 |
|
Toughened Glass for panes: - 11,000/-
Laminated safety glass for panes: - 75,000/-
Laminated safety glass for windscreen: - 87,000/-
Toughened glass for windscreen: - 15,000/-
Plastic glazing: - 139,000/- |
| 5.2.2(b) Resistance to Fire) |
- |
7000 |
|
Toughened Glass for panes: - 11,000/-
Laminated safety glass for panes: - 75,000/-
Laminated safety glass for windscreen: - 87,000/-
Toughened glass for windscreen: - 15,000/-
Plastic glazing: - 139,000/- |
| 5.3.1 (Resistance to Radiation) |
- |
9000 |
|
Toughened Glass for panes: - 11,000/-
Laminated safety glass for panes: - 75,000/-
Laminated safety glass for windscreen: - 87,000/-
Toughened glass for windscreen: - 15,000/-
Plastic glazing: - 139,000/- |
| 5.3.2(Resistance to High
Temperature) |
- |
2000 |
|
Toughened Glass for panes: - 11,000/-
Laminated safety glass for panes: - 75,000/-
Laminated safety glass for windscreen: - 87,000/-
Toughened glass for windscreen: - 15,000/-
Plastic glazing: - 139,000/- |
| 5.3.3.1(Resistance to Humidity) |
- |
23500 |
|
Toughened Glass for panes: - 11,000/-
Laminated safety glass for panes: - 75,000/-
Laminated safety glass for windscreen: - 87,000/-
Toughened glass for windscreen: - 15,000/-
Plastic glazing: - 139,000/- |
| 5.3.3.2(Resistance to Humidity) |
- |
23500 |
|
Toughened Glass for panes: - 11,000/-
Laminated safety glass for panes: - 75,000/-
Laminated safety glass for windscreen: - 87,000/-
Toughened glass for windscreen: - 15,000/-
Plastic glazing: - 139,000/- |
| 5.3.3.2(Resistance to Humidity) |
- |
23500 |
|
Toughened Glass for panes: - 11,000/-
Laminated safety glass for panes: - 75,000/-
Laminated safety glass for windscreen: - 87,000/-
Toughened glass for windscreen: - 15,000/-
Plastic glazing: - 139,000/- |
| 5.3.3.3(Resistance to Humidity) |
- |
6500 |
|
Toughened Glass for panes: - 11,000/-
Laminated safety glass for panes: - 75,000/-
Laminated safety glass for windscreen: - 87,000/-
Toughened glass for windscreen: - 15,000/-
Plastic glazing: - 139,000/- |
| 5.4.1(Optical Distortion) |
- |
5700 |
|
Toughened Glass for panes: - 11,000/-
Laminated safety glass for panes: - 75,000/-
Laminated safety glass for windscreen: - 87,000/-
Toughened glass for windscreen: - 15,000/-
Plastic glazing: - 139,000/- |
| 5.4.1.3 (Optical Distortion) |
- |
5700 |
|
Toughened Glass for panes: - 11,000/-
Laminated safety glass for panes: - 75,000/-
Laminated safety glass for windscreen: - 87,000/-
Toughened glass for windscreen: - 15,000/-
Plastic glazing: - 139,000/- |
| 5.4.2(Secondary image separation test-Vehicle Category M1 and N -Zone A) |
- |
5700 |
|
Toughened Glass for panes: - 11,000/-
Laminated safety glass for panes: - 75,000/-
Laminated safety glass for windscreen: - 87,000/-
Toughened glass for windscreen: - 15,000/-
Plastic glazing: - 139,000/- |
| 5.4.2(Secondary image separation test-Vehicle Category M1 and N -Zone B) |
- |
5700 |
|
Toughened Glass for panes: - 11,000/-
Laminated safety glass for panes: - 75,000/-
Laminated safety glass for windscreen: - 87,000/-
Toughened glass for windscreen: - 15,000/-
Plastic glazing: - 139,000/- |
| 5.4.2(Secondary image separation test-Vehicle Category L -Zone Primary area) |
- |
5700 |
|
Toughened Glass for panes: - 11,000/-
Laminated safety glass for panes: - 75,000/-
Laminated safety glass for windscreen: - 87,000/-
Toughened glass for windscreen: - 15,000/-
Plastic glazing: - 139,000/- |
| 5.4.2(Secondary image separation test-Vehicle Category L -Zone Secondary area) |
- |
5700 |
|
Toughened Glass for panes: - 11,000/-
Laminated safety glass for panes: - 75,000/-
Laminated safety glass for windscreen: - 87,000/-
Toughened glass for windscreen: - 15,000/-
Plastic glazing: - 139,000/- |
| 5.4.2(Secondary image separation test-Vehicle Category M2 , M3 and N -central area) |
- |
5700 |
|
Toughened Glass for panes: - 11,000/-
Laminated safety glass for panes: - 75,000/-
Laminated safety glass for windscreen: - 87,000/-
Toughened glass for windscreen: - 15,000/-
Plastic glazing: - 139,000/- |
| 5.4.2.3(Secondary image separation test) |
- |
5700 |
|
Toughened Glass for panes: - 11,000/-
Laminated safety glass for panes: - 75,000/-
Laminated safety glass for windscreen: - 87,000/-
Toughened glass for windscreen: - 15,000/-
Plastic glazing: - 139,000/- |
| 5.4.3.1(Head-form Test (Location of crack)) |
- |
7000 |
|
Toughened Glass for panes: - 11,000/-
Laminated safety glass for panes: - 75,000/-
Laminated safety glass for windscreen: - 87,000/-
Toughened glass for windscreen: - 15,000/-
Plastic glazing: - 139,000/- |
| 5.4.3.2(Head-form Test (Interlayer adhesion)) |
- |
7000 |
|
Toughened Glass for panes: - 11,000/-
Laminated safety glass for panes: - 75,000/-
Laminated safety glass for windscreen: - 87,000/-
Toughened glass for windscreen: - 15,000/-
Plastic glazing: - 139,000/- |
| 5.4.3.3.1(Head-form Test) |
- |
7200 |
|
Toughened Glass for panes: - 11,000/-
Laminated safety glass for panes: - 75,000/-
Laminated safety glass for windscreen: - 87,000/-
Toughened glass for windscreen: - 15,000/-
Plastic glazing: - 139,000/- |
| 5.4.3.3.2(Head-form Test) |
- |
7200 |
|
Toughened Glass for panes: - 11,000/-
Laminated safety glass for panes: - 75,000/-
Laminated safety glass for windscreen: - 87,000/-
Toughened glass for windscreen: - 15,000/-
Plastic glazing: - 139,000/- |
| 5.4.4(2.260 g Ball) |
- |
5000 |
|
Toughened Glass for panes: - 11,000/-
Laminated safety glass for panes: - 75,000/-
Laminated safety glass for windscreen: - 87,000/-
Toughened glass for windscreen: - 15,000/-
Plastic glazing: - 139,000/- |
| 5.4.5.1(227 g Ball) |
- |
5000 |
|
Toughened Glass for panes: - 11,000/-
Laminated safety glass for panes: - 75,000/-
Laminated safety glass for windscreen: - 87,000/-
Toughened glass for windscreen: - 15,000/-
Plastic glazing: - 139,000/- |
| 5.4.5.2(227 g Ball) |
- |
5000 |
|
Toughened Glass for panes: - 11,000/-
Laminated safety glass for panes: - 75,000/-
Laminated safety glass for windscreen: - 87,000/-
Toughened glass for windscreen: - 15,000/-
Plastic glazing: - 139,000/- |
| 5.4.5.3(227 g Ball) |
- |
5000 |
|
Toughened Glass for panes: - 11,000/-
Laminated safety glass for panes: - 75,000/-
Laminated safety glass for windscreen: - 87,000/-
Toughened glass for windscreen: - 15,000/-
Plastic glazing: - 139,000/- |
| 5.4.5.4(227 g Ball) |
- |
5000 |
|
Toughened Glass for panes: - 11,000/-
Laminated safety glass for panes: - 75,000/-
Laminated safety glass for windscreen: - 87,000/-
Toughened glass for windscreen: - 15,000/-
Plastic glazing: - 139,000/- |
| 5.5.1.1.1(Fragmentation Test) |
- |
4000 |
|
Toughened Glass for panes: - 11,000/-
Laminated safety glass for panes: - 75,000/-
Laminated safety glass for windscreen: - 87,000/-
Toughened glass for windscreen: - 15,000/-
Plastic glazing: - 139,000/- |
| 5.5.1.1.4(Fragmentation Test) |
- |
4000 |
|
Toughened Glass for panes: - 11,000/-
Laminated safety glass for panes: - 75,000/-
Laminated safety glass for windscreen: - 87,000/-
Toughened glass for windscreen: - 15,000/-
Plastic glazing: - 139,000/- |
| 5.5.1.1.5(Fragmentation Test) |
- |
4000 |
|
Toughened Glass for panes: - 11,000/-
Laminated safety glass for panes: - 75,000/-
Laminated safety glass for windscreen: - 87,000/-
Toughened glass for windscreen: - 15,000/-
Plastic glazing: - 139,000/- |
| 5.5.1.1.5.1(Fragmentation Test) |
- |
4000 |
|
Toughened Glass for panes: - 11,000/-
Laminated safety glass for panes: - 75,000/-
Laminated safety glass for windscreen: - 87,000/-
Toughened glass for windscreen: - 15,000/-
Plastic glazing: - 139,000/- |
| 5.5.1.1.5.2(Fragmentation Test) |
- |
4000 |
|
Toughened Glass for panes: - 11,000/-
Laminated safety glass for panes: - 75,000/-
Laminated safety glass for windscreen: - 87,000/-
Toughened glass for windscreen: - 15,000/-
Plastic glazing: - 139,000/- |
| 5.5.1.2(227 g ball test) |
- |
1900 |
|
Toughened Glass for panes: - 11,000/-
Laminated safety glass for panes: - 75,000/-
Laminated safety glass for windscreen: - 87,000/-
Toughened glass for windscreen: - 15,000/-
Plastic glazing: - 139,000/- |
| 5.5.2.1.1(227 g ball test) |
- |
600 |
|
Toughened Glass for panes: - 11,000/-
Laminated safety glass for panes: - 75,000/-
Laminated safety glass for windscreen: - 87,000/-
Toughened glass for windscreen: - 15,000/-
Plastic glazing: - 139,000/- |
| 5.5.2.1.2(227 g ball test) |
- |
600 |
|
Toughened Glass for panes: - 11,000/-
Laminated safety glass for panes: - 75,000/-
Laminated safety glass for windscreen: - 87,000/-
Toughened glass for windscreen: - 15,000/-
Plastic glazing: - 139,000/- |
| 5.5.2.1.3(227 g ball test) |
- |
600 |
|
Toughened Glass for panes: - 11,000/-
Laminated safety glass for panes: - 75,000/-
Laminated safety glass for windscreen: - 87,000/-
Toughened glass for windscreen: - 15,000/-
Plastic glazing: - 139,000/- |
| 5.5.3.1(equirements Applicable only to Double-Glazed
Units-Individual components) |
- |
5500 |
|
Toughened Glass for panes: - 11,000/-
Laminated safety glass for panes: - 75,000/-
Laminated safety glass for windscreen: - 87,000/-
Toughened glass for windscreen: - 15,000/-
Plastic glazing: - 139,000/- |
| 5.5.3.2.1( Head-form Test) |
- |
9000 |
|
Toughened Glass for panes: - 11,000/-
Laminated safety glass for panes: - 75,000/-
Laminated safety glass for windscreen: - 87,000/-
Toughened glass for windscreen: - 15,000/-
Plastic glazing: - 139,000/- |
| 5.5.3.2.2.1( Head-form Test) |
- |
9000 |
|
Toughened Glass for panes: - 11,000/-
Laminated safety glass for panes: - 75,000/-
Laminated safety glass for windscreen: - 87,000/-
Toughened glass for windscreen: - 15,000/-
Plastic glazing: - 139,000/- |
| 5.5.3.2.2.2( Head-form Test) |
- |
9000 |
|
Toughened Glass for panes: - 11,000/-
Laminated safety glass for panes: - 75,000/-
Laminated safety glass for windscreen: - 87,000/-
Toughened glass for windscreen: - 15,000/-
Plastic glazing: - 139,000/- |
| 5.5.3.2.2.3( Head-form Test) |
- |
9000 |
|
Toughened Glass for panes: - 11,000/-
Laminated safety glass for panes: - 75,000/-
Laminated safety glass for windscreen: - 87,000/-
Toughened glass for windscreen: - 15,000/-
Plastic glazing: - 139,000/- |
| 5.5.3.2.3-a( Head-form Test) |
- |
9000 |
|
Toughened Glass for panes: - 11,000/-
Laminated safety glass for panes: - 75,000/-
Laminated safety glass for windscreen: - 87,000/-
Toughened glass for windscreen: - 15,000/-
Plastic glazing: - 139,000/- |
| 5.5.3.2.3-b-1( Head-form Test) |
- |
9000 |
|
Toughened Glass for panes: - 11,000/-
Laminated safety glass for panes: - 75,000/-
Laminated safety glass for windscreen: - 87,000/-
Toughened glass for windscreen: - 15,000/-
Plastic glazing: - 139,000/- |
| 5.5.3.2.3-b-2( Head-form Test) |
- |
9000 |
|
Toughened Glass for panes: - 11,000/-
Laminated safety glass for panes: - 75,000/-
Laminated safety glass for windscreen: - 87,000/-
Toughened glass for windscreen: - 15,000/-
Plastic glazing: - 139,000/- |
| 5.5.3.2.3-b-3( Head-form Test) |
- |
9000 |
|
Toughened Glass for panes: - 11,000/-
Laminated safety glass for panes: - 75,000/-
Laminated safety glass for windscreen: - 87,000/-
Toughened glass for windscreen: - 15,000/-
Plastic glazing: - 139,000/- |
| 5.6.1.7( Head-form Test) |
- |
9000 |
|
Toughened Glass for panes: - 11,000/-
Laminated safety glass for panes: - 75,000/-
Laminated safety glass for windscreen: - 87,000/-
Toughened glass for windscreen: - 15,000/-
Plastic glazing: - 139,000/- |
| 5.6.1.8( Head-form Test-The HIC value ) |
- |
9000 |
|
Toughened Glass for panes: - 11,000/-
Laminated safety glass for panes: - 75,000/-
Laminated safety glass for windscreen: - 87,000/-
Toughened glass for windscreen: - 15,000/-
Plastic glazing: - 139,000/- |
| 5.6.2.4-a(Mechanical Strength Test — 227g Ball) |
- |
6000 |
|
Toughened Glass for panes: - 11,000/-
Laminated safety glass for panes: - 75,000/-
Laminated safety glass for windscreen: - 87,000/-
Toughened glass for windscreen: - 15,000/-
Plastic glazing: - 139,000/- |
| 5.6.2.4-b(Mechanical Strength Test — 227g Ball) |
- |
6000 |
|
Toughened Glass for panes: - 11,000/-
Laminated safety glass for panes: - 75,000/-
Laminated safety glass for windscreen: - 87,000/-
Toughened glass for windscreen: - 15,000/-
Plastic glazing: - 139,000/- |
| 5.6.2.5(Mechanical Strength Test — 227g Ball test at –18° ± 2°C) |
- |
6000 |
|
Toughened Glass for panes: - 11,000/-
Laminated safety glass for panes: - 75,000/-
Laminated safety glass for windscreen: - 87,000/-
Toughened glass for windscreen: - 15,000/-
Plastic glazing: - 139,000/- |
| 5.6.2.5(Mechanical Strength Test — 227g Ball test at –18° ± 2°C) |
- |
6000 |
|
Toughened Glass for panes: - 11,000/-
Laminated safety glass for panes: - 75,000/-
Laminated safety glass for windscreen: - 87,000/-
Toughened glass for windscreen: - 15,000/-
Plastic glazing: - 139,000/- |
| 5.6.3.3(Flexibility and Fold Test) |
- |
7500 |
|
Toughened Glass for panes: - 11,000/-
Laminated safety glass for panes: - 75,000/-
Laminated safety glass for windscreen: - 87,000/-
Toughened glass for windscreen: - 15,000/-
Plastic glazing: - 139,000/- |
| 5.6.4.4-a(Weathering) |
- |
9500 |
|
Toughened Glass for panes: - 11,000/-
Laminated safety glass for panes: - 75,000/-
Laminated safety glass for windscreen: - 87,000/-
Toughened glass for windscreen: - 15,000/-
Plastic glazing: - 139,000/- |
| 5.6.4.4-b(Weathering) |
- |
9500 |
|
Toughened Glass for panes: - 11,000/-
Laminated safety glass for panes: - 75,000/-
Laminated safety glass for windscreen: - 87,000/-
Toughened glass for windscreen: - 15,000/-
Plastic glazing: - 139,000/- |
| 5.6.5.3-a(Cross-cut) |
- |
9000 |
|
Toughened Glass for panes: - 11,000/-
Laminated safety glass for panes: - 75,000/-
Laminated safety glass for windscreen: - 87,000/-
Toughened glass for windscreen: - 15,000/-
Plastic glazing: - 139,000/- |
| 5.6.5.3-b-1(Cross-cut) |
- |
9000 |
|
Toughened Glass for panes: - 11,000/-
Laminated safety glass for panes: - 75,000/-
Laminated safety glass for windscreen: - 87,000/-
Toughened glass for windscreen: - 15,000/-
Plastic glazing: - 139,000/- |
| 5.7.1.1(227 g Ball Test at 20 ± 5°C) |
- |
6000 |
|
Toughened Glass for panes: - 11,000/-
Laminated safety glass for panes: - 75,000/-
Laminated safety glass for windscreen: - 87,000/-
Toughened glass for windscreen: - 15,000/-
Plastic glazing: - 139,000/- |
| 5.7.2.1(227g Ball Test at –18° ± 2°C) |
- |
6000 |
|
Toughened Glass for panes: - 11,000/-
Laminated safety glass for panes: - 75,000/-
Laminated safety glass for windscreen: - 87,000/-
Toughened glass for windscreen: - 15,000/-
Plastic glazing: - 139,000/- |
| 5.7.3.1(Flexibility Test and Fold Test) |
- |
8500 |
|
Toughened Glass for panes: - 11,000/-
Laminated safety glass for panes: - 75,000/-
Laminated safety glass for windscreen: - 87,000/-
Toughened glass for windscreen: - 15,000/-
Plastic glazing: - 139,000/- |
| 5.7.3.1(Flexibility Test and Fold Test) |
- |
8500 |
|
Toughened Glass for panes: - 11,000/-
Laminated safety glass for panes: - 75,000/-
Laminated safety glass for windscreen: - 87,000/-
Toughened glass for windscreen: - 15,000/-
Plastic glazing: - 139,000/- |
| 5.4.5(227 g Ball test) |
- |
7500 |
|
Toughened Glass for panes: - 11,000/-
Laminated safety glass for panes: - 75,000/-
Laminated safety glass for windscreen: - 87,000/-
Toughened glass for windscreen: - 15,000/-
Plastic glazing: - 139,000/- |
| As per Clause 3.7(Wind screen and Panes) |
- |
23500 |
|
Toughened Glass for panes: - 11,000/-
Laminated safety glass for panes: - 75,000/-
Laminated safety glass for windscreen: - 87,000/-
Toughened glass for windscreen: - 15,000/-
Plastic glazing: - 139,000/- |
| As per Clause 4.1(Wind screen and Panes) |
- |
23500 |
|
Toughened Glass for panes: - 11,000/-
Laminated safety glass for panes: - 75,000/-
Laminated safety glass for windscreen: - 87,000/-
Toughened glass for windscreen: - 15,000/-
Plastic glazing: - 139,000/- |
| As per Clause 5.8.2(Wind screen) |
- |
9500 |
|
Toughened Glass for panes: - 11,000/-
Laminated safety glass for panes: - 75,000/-
Laminated safety glass for windscreen: - 87,000/-
Toughened glass for windscreen: - 15,000/-
Plastic glazing: - 139,000/- |
| As per Clause 5.8.3(Wind screen) |
- |
9500 |
|
Toughened Glass for panes: - 11,000/-
Laminated safety glass for panes: - 75,000/-
Laminated safety glass for windscreen: - 87,000/-
Toughened glass for windscreen: - 15,000/-
Plastic glazing: - 139,000/- |
| 5.4.3.1(Head-form Test (Location of crack)) |
- |
0 |
|
- |
| 5.4.3.2(Head-form Test (Interlayer adhesion)) |
- |
0 |
|
- |
| 5.4.5(227 g Ball test) |
- |
0 |
|
- |
| As per Clause 3.7(Wind screen and Panes) |
- |
0 |
|
- |
| As per Clause 4.1(Wind screen and Panes) |
- |
0 |
|
- |
| As per Clause 5.8.2(Wind screen) |
- |
0 |
|
- |
| As per Clause 5.8.3(Wind screen) |
- |
0 |
|
- |
| 5.4.3.1(Head-form Test (Location of crack)) |
- |
0 |
|
- |
| 5.4.3.2(Head-form Test (Interlayer adhesion)) |
- |
0 |
|
- |
| 5.4.5(227 g Ball test) |
- |
0 |
|
- |
| As per Clause 3.7(Wind screen and Panes) |
- |
0 |
|
- |
| As per Clause 4.1(Wind screen and Panes) |
- |
0 |
|
- |
| As per Clause 5.8.2(Wind screen) |
- |
0 |
|
- |
| As per Clause 5.8.3(Wind screen) |
- |
0 |
|
- |
| 5.4.3.1(Head-form Test (Location of crack)) |
- |
0 |
|
- |
| 5.4.3.2(Head-form Test (Interlayer adhesion)) |
- |
0 |
|
- |
| 5.4.5(227 g Ball test) |
- |
0 |
|
- |
| As per Clause 3.7(Wind screen and Panes) |
- |
0 |
|
- |
| As per Clause 4.1(Wind screen and Panes) |
- |
0 |
|
- |
| As per Clause 5.8.2(Wind screen) |
- |
0 |
|
- |
| As per Clause 5.8.3(Wind screen) |
- |
0 |
|
- |
|
- |
- Included w.e.f 28.07.2025 |
| 5383 |
EMC Testing and Compliance LLP, Gurugram
| 8141526
| IS 302 : Part 2 : Sec 11 (1994) |
Safety of household and similar electrical appliances: Part 2 particular requirements: Sec 11 tumbler dryers |
- |
50000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 3(GENERAL REQUIREMENT) |
- |
2000 |
|
- |
| 4(GENERAL NOTES ON TESTS) |
- |
2000 |
|
- |
| 5(RATING) |
- |
2000 |
|
- |
| 6(CLASSIFICATION) |
- |
2000 |
|
- |
| 7(MARKING) |
- |
2000 |
|
- |
| 8(PROTECTION AGAINST ELECTRIC SHOCK) |
- |
2000 |
|
- |
| 9(STARTING OF MOTOR-OPERATED APPLIANCES) |
- |
0 |
|
- |
| 10(INPUT AND CURRENT) |
- |
2000 |
|
- |
| 11(HEATING) |
- |
2000 |
|
- |
| 12(OPERATION TJNDER OVERLOAD CONDITIONS
OF APPLIANCES WITH HEATING ELEMENTS) |
- |
0 |
|
- |
| 13(ELECTRICAL INSULATION AND LEAKAGE CURRENT AT
OPERATING TEMPERATURE) |
- |
2000 |
|
- |
| 14(RADIO AND TELEVISION INTERFERENCE SUPPRESSION) |
- |
2000 |
|
- |
| 15(MOISTURE RESISTANCE) |
- |
3000 |
|
- |
| 16(INSULATION RESISTANCE AND ELECTRIC STRENGTH) |
- |
2000 |
|
- |
| 17(OVERLOAD PROTECTION) |
- |
2000 |
|
- |
| 18(ENDURANCE ) |
- |
0 |
|
- |
| 19(ABNORMAL OPERATION) |
- |
2000 |
|
- |
| 20(STABILITY AND MECHANICAL HAZARDS) |
- |
2000 |
|
- |
| 21(MECHANICAL STRENGTH) |
- |
2000 |
|
- |
| 22(CONSTRUCTION) |
- |
2000 |
|
- |
| 23(INTERNAL WIRING) |
- |
2000 |
|
- |
| 24(COMPONENTS) |
- |
2000 |
|
- |
| 25(SUPPLY CONNECTION AND EXTERNAL FLEXIBLE CABLES AND CORDS) |
- |
2000 |
|
- |
| 26(TERMINALS FOR EXTERNAL CONDUCTORS) |
- |
2000 |
|
- |
| 27(PROVISION FOR EARTHING) |
- |
2000 |
|
- |
| 28(SCREWS AND CONNECTIONS) |
- |
2000 |
|
- |
| 29(CREEPAGE DISTANCES, CLEARANCES AND DISTANCES THROUGH INSULATION) |
- |
2000 |
|
- |
| 30(RESISTANCE TO HEAT, FIRE AND TACKING) |
- |
2000 |
|
- |
| 31(RESISTANCE TO RUSTING) |
- |
2000 |
|
- |
| 101.1(Type Tests) |
- |
2000 |
|
- |
| 101.2(Acceptance Tests) |
- |
2000 |
|
- |
| 101.3(Routine Tests) |
- |
2000 |
|
- |
| 3(GENERAL REQUIREMENT) |
- |
2000 |
|
- |
| 4(GENERAL NOTES ON TESTS) |
- |
2000 |
|
- |
| 5(RATING) |
- |
2000 |
|
- |
| 6(CLASSIFICATION) |
- |
2000 |
|
- |
| 7(MARKING) |
- |
2000 |
|
- |
| 8(PROTECTION AGAINST ELECTRIC SHOCK) |
- |
2000 |
|
- |
| 9(STARTING OF MOTOR-OPERATED APPLIANCES) |
- |
0 |
|
- |
| 10(INPUT AND CURRENT) |
- |
2000 |
|
- |
| 11(HEATING) |
- |
2000 |
|
- |
| 12(OPERATION TJNDER OVERLOAD CONDITIONS
OF APPLIANCES WITH HEATING ELEMENTS) |
- |
0 |
|
- |
| 13(ELECTRICAL INSULATION AND LEAKAGE CURRENT AT
OPERATING TEMPERATURE) |
- |
2000 |
|
- |
| 14(RADIO AND TELEVISION INTERFERENCE SUPPRESSION) |
- |
2000 |
|
- |
| 15(MOISTURE RESISTANCE) |
- |
2000 |
|
- |
| 16(INSULATION RESISTANCE AND ELECTRIC STRENGTH) |
- |
2000 |
|
- |
| 17(OVERLOAD PROTECTION) |
- |
2000 |
|
- |
| 18(ENDURANCE ) |
- |
0 |
|
- |
| 19(ABNORMAL OPERATION) |
- |
2000 |
|
- |
| 20(STABILITY AND MECHANICAL HAZARDS) |
- |
2000 |
|
- |
| 21(MECHANICAL STRENGTH) |
- |
2000 |
|
- |
| 22(CONSTRUCTION) |
- |
2000 |
|
- |
| 23(INTERNAL WIRING) |
- |
2000 |
|
- |
| 25(SUPPLY CONNECTION AND EXTERNAL FLEXIBLE CABLES AND CORDS) |
- |
2000 |
|
- |
| 26(TERMINALS FOR EXTERNAL CONDUCTORS) |
- |
2000 |
|
- |
| 27(PROVISION FOR EARTHING) |
- |
2000 |
|
- |
| 28(SCREWS AND CONNECTIONS) |
- |
2000 |
|
- |
| 29(CREEPAGE DISTANCES, CLEARANCES AND DISTANCES THROUGH INSULATION) |
- |
2000 |
|
- |
| 30(RESISTANCE TO HEAT, FIRE AND TACKING) |
- |
2000 |
|
- |
| 31(RESISTANCE TO RUSTING) |
- |
2000 |
|
- |
| 101.1(Type Tests) |
- |
2000 |
|
- |
| 101.2(Acceptance Tests) |
- |
2000 |
|
- |
| 101.3(Routine Tests) |
- |
2000 |
|
- |
| 3(GENERAL REQUIREMENT) |
- |
- |
|
- |
| 4(GENERAL NOTES ON TESTS) |
- |
- |
|
- |
| 5(RATING) |
- |
- |
|
- |
| 6(CLASSIFICATION) |
- |
- |
|
- |
| 7(MARKING) |
- |
- |
|
- |
| 8(PROTECTION AGAINST ELECTRIC SHOCK) |
- |
- |
|
- |
| 9(STARTING OF MOTOR-OPERATED APPLIANCES) |
- |
- |
|
- |
| 10(INPUT AND CURRENT) |
- |
- |
|
- |
| 11(HEATING) |
- |
- |
|
- |
| 12(OPERATION TJNDER OVERLOAD CONDITIONS
OF APPLIANCES WITH HEATING ELEMENTS) |
- |
- |
|
- |
| 13(ELECTRICAL INSULATION AND LEAKAGE CURRENT AT
OPERATING TEMPERATURE) |
- |
- |
|
- |
| 14(RADIO AND TELEVISION INTERFERENCE SUPPRESSION) |
- |
- |
|
- |
| 15(MOISTURE RESISTANCE) |
- |
- |
|
- |
| 16(INSULATION RESISTANCE AND ELECTRIC STRENGTH) |
- |
- |
|
- |
| 17(OVERLOAD PROTECTION) |
- |
- |
|
- |
| 18(ENDURANCE ) |
- |
- |
|
- |
| 19(ABNORMAL OPERATION) |
- |
- |
|
- |
| 20(STABILITY AND MECHANICAL HAZARDS) |
- |
- |
|
- |
| 21(MECHANICAL STRENGTH) |
- |
- |
|
- |
| 22(CONSTRUCTION) |
- |
- |
|
- |
| 23(INTERNAL WIRING) |
- |
- |
|
- |
| 25(SUPPLY CONNECTION AND EXTERNAL FLEXIBLE CABLES AND CORDS) |
- |
- |
|
- |
| 26(TERMINALS FOR EXTERNAL CONDUCTORS) |
- |
- |
|
- |
| 27(PROVISION FOR EARTHING) |
- |
- |
|
- |
| 28(SCREWS AND CONNECTIONS) |
- |
- |
|
- |
| 29(CREEPAGE DISTANCES, CLEARANCES AND DISTANCES THROUGH INSULATION) |
- |
- |
|
- |
| 30(RESISTANCE TO HEAT, FIRE AND TACKING) |
- |
- |
|
- |
| 31(RESISTANCE TO RUSTING) |
- |
- |
|
- |
| 101.1(Type Tests) |
- |
- |
|
- |
| 101.2(Acceptance Tests) |
- |
- |
|
- |
| 101.3(Routine Tests) |
- |
- |
|
- |
|
19 Jul, 2027 |
- Included w.e.f.22.07.2025
Exclusion
Cl 19.11.4.1 to 19.11.4.7(EMI/EMC)
32 (Radiation, toxicity and similar hazards) |
| 5384 |
Excel Surveyors Pvt. Ltd., Kolkata
| 5135906
| IS 2074 (2023) |
Ready Mixed Paint Air Drying Red Oxide Zinc Chrome Priming -Specification (Fourth Revision) |
NA |
9700 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl-4(The smell of the material shall not be objectionable during application) |
- |
0 |
|
Facilty Not available |
| Cl-5.1 (a)(Pigment) |
- |
350 |
|
- |
| Cl-5.1 (b)(Driers) |
- |
0 |
|
Facility for Identification of type of driers not available |
| Cl-5.1.1 (a)("Zinc oxide content
Chromic anhydride content") |
- |
900 |
|
- |
| Cl-5.1.1 (b)(Synthetic red oxides of iron or Natural red oxides of iron or A mixture of both which shall correspond to red oxide, percent by mass) |
- |
500 |
|
- |
| Cl-5.1.1 (c)(Suitable extenders) |
- |
0 |
|
Facilty Not available |
| Cl-5.2(Material) |
- |
0 |
|
Facilty Not available |
| Cl-5.3(Compatibility with Thinner) |
- |
150 |
|
- |
| Cl-5.4(Freedom from Objectionable Impurities) |
- |
0 |
|
Facilty Not available |
| Cl-5.5(Lead Restriction) |
- |
400 |
|
- |
| Cl-5.6 & 8 Table-1 (i) (a)(Consistency) |
- |
150 |
|
- |
| Cl-5.6 & 8, Table-1 (i) (b)(Viscosity by ford cup No. 4 at 27±2°C) |
- |
200 |
|
- |
| Cl-5.6 & 8, Table-1 (ii)(Mass, in kg/10 1, Min) |
- |
200 |
|
- |
| Cl-5.6 & 8, Table-1 (iii)("Drying time, h, Max
a) Surface dry
b) Hard dry") |
- |
400 |
|
- |
| Cl-5.6 & 8, Table-1 (iv)(a) Finish) |
- |
150 |
|
- |
| Cl-5.6 & 8, Table-1 (iv)(b) Gloss 60° , Max) |
- |
250 |
|
- |
| Cl-5.6 & 8, Table-1 (v)(Fineness of grind, microns, Max) |
- |
200 |
|
- |
| Cl-5.6 & 8, Table-1 (vi)(Colour) |
- |
150 |
|
- |
| Cl-5.6 & 8,, Table-1 (vii) a)(Flexibility and adhesion: Bend test with 6.25mm dia mandrel and in type 1 apparatus) |
- |
200 |
|
- |
| Cl-5.6 & 8,, Table-1 (vii) b)(Flexibility and adhesion: Scratch hardness) |
- |
200 |
|
- |
| Cl-5.6 & 8, Table-1 (viii)(Flash point) |
- |
400 |
|
- |
| Cl-5.6 & 8,, Table-1 (ix)(Volume solids, percent) |
- |
400 |
|
- |
| Cl-5.6 & 8,, Table-1 (x) (a)(Resistance to humidity) |
- |
1000 |
|
- |
| Cl-5.6 & 8, Table-1 (x) (b)("Resistance to sea
water (applicable for marine
paints only)") |
- |
500 |
|
- |
| Cl-5.6 & 8, Table-1 (x) (c)(Resistance to salt spray) |
- |
500 |
|
- |
| Cl-5.6 & 8, Table-1 (xi)(Accelerated storage stability test) |
- |
1000 |
|
- |
| Cl-5.6 & 8, Table-1 (xii)("Keeping properties
Visual observation
(Corrosion and odour of putrefaction, rancidity or souring) ") |
- |
0 |
|
- |
| Cl-5.6 & 8, Table-1 (xii)("Keeping properties
Change in skinning") |
- |
0 |
|
- |
| Cl-5.6 & 8, Table-1 (xii)("Keeping properties
Degree of settling ") |
- |
0 |
|
- |
| Cl-5.6 & 8, Table-1 (xii)("Keeping properties
Observation of dried film ") |
- |
0 |
|
- |
| Cl-5.6 & 8, Table-1 (xii)("Keeping properties
Loss of mass resulting from Storage ") |
- |
0 |
|
- |
| Cl-5.7, Table-2 (i)(Consistency) |
- |
200 |
|
- |
| Cl-5.7, Table-2 (ii)(Hard dry, h, Max) |
- |
200 |
|
- |
| Cl-5.7, Table-2 (iii)(Non- volatile vehicle, percent, Min) |
- |
350 |
|
- |
| Cl-5.7, Table-2 (iv)(Wet opacity, m2 /10 l, Min) |
- |
250 |
|
- |
| Cl-4(The smell of the material shall not be objectionable during application) |
- |
0 |
|
Facility Not available |
| Cl-5.1 (a)(Pigment) |
- |
0 |
|
- |
| Cl-5.1 (b)(Driers) |
- |
0 |
|
Facility Not available |
| Cl-5.1.1 (a)("Zinc oxide content
Chromic anhydride content") |
- |
0 |
|
- |
| Cl-5.1.1 (b)(Synthetic red oxides of iron or Natural red oxides of iron or A mixture of both which shall correspond to red oxide, percent by mass) |
- |
0 |
|
- |
| Cl-5.1.1 (c)(Suitable extenders) |
- |
0 |
|
Facility Not available |
| Cl-5.2(Material) |
- |
0 |
|
Facility Not available |
| Cl-5.3(Compatibility with Thinner) |
- |
0 |
|
- |
| Cl-5.4(Freedom from Objectionable Impurities) |
- |
0 |
|
Facility Not available |
| Cl-5.5(Lead Restriction) |
- |
0 |
|
- |
| Cl-5.6 & 8 Table-1 (i) (a)(Consistency) |
- |
0 |
|
- |
| Cl-5.6 & 8, Table-1 (i) (b)(Viscosity by ford cup No. 4 at 27±2°C) |
- |
0 |
|
- |
| Cl-5.6 & 8, Table-1 (ii)(Mass, in kg/10 1, Min) |
- |
0 |
|
- |
| Cl-5.6 & 8, Table-1 (iii)("Drying time, h, Max
a) Surface dry
b) Hard dry") |
- |
0 |
|
- |
| Cl-5.6 & 8, Table-1 (iv)(a) Finish) |
- |
0 |
|
- |
| Cl-5.6 & 8, Table-1 (iv)(b) Gloss 60° , Max) |
- |
0 |
|
- |
| Cl-5.6 & 8, Table-1 (v)(Fineness of grind, microns, Max) |
- |
0 |
|
- |
| Cl-5.6 & 8, Table-1 (vi)(Colour) |
- |
0 |
|
- |
| Cl-5.6 & 8,, Table-1 (vii) a)(Flexibility and adhesion: Bend test with 6.25mm dia mandrel and in type 1 apparatus) |
- |
0 |
|
- |
| Cl-5.6 & 8,, Table-1 (vii) b)(Flexibility and adhesion: Scratch hardness) |
- |
0 |
|
- |
| Cl-5.6 & 8, Table-1 (viii)(Flash point) |
- |
0 |
|
- |
| Cl-5.6 & 8,, Table-1 (ix)(Volume solids, percent) |
- |
0 |
|
- |
| Cl-5.6 & 8,, Table-1 (x) (a)(Resistance to humidity) |
- |
0 |
|
- |
| Cl-5.6 & 8, Table-1 (x) (b)("Resistance to sea
water (applicable for marine
paints only)") |
- |
0 |
|
- |
| Cl-5.6 & 8, Table-1 (x) (c)(Resistance to salt spray) |
- |
0 |
|
- |
| Cl-5.6 & 8, Table-1 (xi)(Accelerated storage stability test) |
- |
0 |
|
- |
| Cl-5.6 & 8, Table-1 (xii)("Keeping properties
Visual observation
(Corrosion and odour of putrefaction, rancidity or souring) ") |
- |
0 |
|
- |
| Cl-5.6 & 8, Table-1 (xii)("Keeping properties
Change in skinning") |
- |
0 |
|
- |
| Cl-5.6 & 8, Table-1 (xii)("Keeping properties
Degree of settling ") |
- |
0 |
|
- |
| Cl-5.6 & 8, Table-1 (xii)("Keeping properties
Observation of dried film ") |
- |
0 |
|
- |
| Cl-5.6 & 8, Table-1 (xii)("Keeping properties
Loss of mass resulting from Storage ") |
- |
0 |
|
- |
| Cl-5.7, Table-2 (i)(Consistency) |
- |
0 |
|
- |
| Cl-5.7, Table-2 (ii)(Hard dry, h, Max) |
- |
0 |
|
- |
| Cl-5.7, Table-2 (iii)(Non- volatile vehicle, percent, Min) |
- |
0 |
|
- |
| Cl-5.7, Table-2 (iv)(Wet opacity, m2 /10 l, Min) |
- |
0 |
|
- |
| Cl-4(The smell of the material shall not be objectionable during application) |
- |
0 |
|
Facility Not available |
| Cl-5.1 (a)(Pigment) |
- |
0 |
|
- |
| Cl-5.1 (b)(Driers) |
- |
0 |
|
Facility Not available |
| Cl-5.1.1 (a)("Zinc oxide content
Chromic anhydride content") |
- |
0 |
|
- |
| Cl-5.1.1 (b)(Synthetic red oxides of iron or Natural red oxides of iron or A mixture of both which shall correspond to red oxide, percent by mass) |
- |
0 |
|
- |
| Cl-5.1.1 (c)(Suitable extenders) |
- |
0 |
|
Facility Not available |
| Cl-5.2(Material) |
- |
0 |
|
Facility Not available |
| Cl-5.3(Compatibility with Thinner) |
- |
0 |
|
- |
| Cl-5.4(Freedom from Objectionable Impurities) |
- |
0 |
|
Facility Not available |
| Cl-5.5(Lead Restriction) |
- |
0 |
|
- |
| Cl-5.6 & 8 Table-1 (i) (a)(Consistency) |
- |
0 |
|
- |
| Cl-5.6 & 8, Table-1 (i) (b)(Viscosity by ford cup No. 4 at 27±2°C) |
- |
0 |
|
- |
| Cl-5.6 & 8, Table-1 (ii)(Mass, in kg/10 1, Min) |
- |
0 |
|
- |
| Cl-5.6 & 8, Table-1 (iii)("Drying time, h, Max
a) Surface dry
b) Hard dry") |
- |
0 |
|
- |
| Cl-5.6 & 8, Table-1 (iv)(a) Finish) |
- |
0 |
|
- |
| Cl-5.6 & 8, Table-1 (iv)(b) Gloss 60° , Max) |
- |
0 |
|
- |
| Cl-5.6 & 8, Table-1 (v)(Fineness of grind, microns, Max) |
- |
0 |
|
- |
| Cl-5.6 & 8, Table-1 (vi)(Colour) |
- |
0 |
|
- |
| Cl-5.6 & 8,, Table-1 (vii) a)(Flexibility and adhesion: Bend test with 6.25mm dia mandrel and in type 1 apparatus) |
- |
0 |
|
- |
| Cl-5.6 & 8,, Table-1 (vii) b)(Flexibility and adhesion: Scratch hardness) |
- |
0 |
|
- |
| Cl-5.6 & 8, Table-1 (viii)(Flash point) |
- |
0 |
|
- |
| Cl-5.6 & 8,, Table-1 (ix)(Volume solids, percent) |
- |
0 |
|
- |
| Cl-5.6 & 8,, Table-1 (x) (a)(Resistance to humidity) |
- |
0 |
|
- |
| Cl-5.6 & 8, Table-1 (x) (b)("Resistance to sea
water (applicable for marine
paints only)") |
- |
0 |
|
- |
| Cl-5.6 & 8, Table-1 (x) (c)(Resistance to salt spray) |
- |
0 |
|
- |
| Cl-5.6 & 8, Table-1 (xi)(Accelerated storage stability test) |
- |
0 |
|
- |
| Cl-5.6 & 8, Table-1 (xii)("Keeping properties
Visual observation
(Corrosion and odour of putrefaction, rancidity or souring) ") |
- |
0 |
|
- |
| Cl-5.6 & 8, Table-1 (xii)("Keeping properties
Change in skinning") |
- |
0 |
|
- |
| Cl-5.6 & 8, Table-1 (xii)("Keeping properties
Degree of settling ") |
- |
0 |
|
- |
| Cl-5.6 & 8, Table-1 (xii)("Keeping properties
Observation of dried film ") |
- |
0 |
|
- |
| Cl-5.6 & 8, Table-1 (xii)("Keeping properties
Loss of mass resulting from Storage ") |
- |
0 |
|
- |
| Cl-5.7, Table-2 (i)(Consistency) |
- |
0 |
|
- |
| Cl-5.7, Table-2 (ii)(Hard dry, h, Max) |
- |
0 |
|
- |
| Cl-5.7, Table-2 (iii)(Non- volatile vehicle, percent, Min) |
- |
0 |
|
- |
| Cl-5.7, Table-2 (iv)(Wet opacity, m2 /10 l, Min) |
- |
0 |
|
- |
| Cl-4(The smell of the material shall not be objectionable during application) |
- |
0 |
|
- |
| Cl-5.1 (a)(Pigment) |
- |
0 |
|
- |
| Cl-5.1 (b)(Driers) |
- |
0 |
|
- |
| Cl-5.1.1 (a)("Zinc oxide content
Chromic anhydride content") |
- |
0 |
|
- |
| Cl-5.1.1 (b)(Synthetic red oxides of iron or Natural red oxides of iron or A mixture of both which shall correspond to red oxide, percent by mass) |
- |
0 |
|
- |
| Cl-5.1.1 (c)(Suitable extenders) |
- |
0 |
|
- |
| Cl-5.2(Material) |
- |
0 |
|
- |
| Cl-5.3(Compatibility with Thinner) |
- |
0 |
|
- |
| Cl-5.4(Freedom from Objectionable Impurities) |
- |
0 |
|
- |
| Cl-5.5(Lead Restriction) |
- |
0 |
|
- |
| Cl-5.6 & 8 Table-1 (i) (a)(Consistency) |
- |
0 |
|
- |
| Cl-5.6 & 8, Table-1 (i) (b)(Viscosity by ford cup No. 4 at 27±2°C) |
- |
0 |
|
- |
| Cl-5.6 & 8, Table-1 (ii)(Mass, in kg/10 1, Min) |
- |
0 |
|
- |
| Cl-5.6 & 8, Table-1 (iii)("Drying time, h, Max
a) Surface dry
b) Hard dry") |
- |
0 |
|
- |
| Cl-5.6 & 8, Table-1 (iv)(a) Finish) |
- |
0 |
|
- |
| Cl-5.6 & 8, Table-1 (iv)(b) Gloss 60° , Max) |
- |
0 |
|
- |
| Cl-5.6 & 8, Table-1 (v)(Fineness of grind, microns, Max) |
- |
0 |
|
- |
| Cl-5.6 & 8, Table-1 (vi)(Colour) |
- |
0 |
|
- |
| Cl-5.6 & 8,, Table-1 (vii) a)(Flexibility and adhesion: Bend test with 6.25mm dia mandrel and in type 1 apparatus) |
- |
0 |
|
- |
| Cl-5.6 & 8,, Table-1 (vii) b)(Flexibility and adhesion: Scratch hardness) |
- |
0 |
|
- |
| Cl-5.6 & 8, Table-1 (viii)(Flash point) |
- |
0 |
|
- |
| Cl-5.6 & 8,, Table-1 (ix)(Volume solids, percent) |
- |
0 |
|
- |
| Cl-5.6 & 8,, Table-1 (x) (a)(Resistance to humidity) |
- |
0 |
|
- |
| Cl-5.6 & 8, Table-1 (x) (b)("Resistance to sea
water (applicable for marine
paints only)") |
- |
0 |
|
- |
| Cl-5.6 & 8, Table-1 (x) (c)(Resistance to salt spray) |
- |
0 |
|
- |
| Cl-5.6 & 8, Table-1 (xi)(Accelerated storage stability test) |
- |
0 |
|
- |
| Cl-5.6 & 8, Table-1 (xii)("Keeping properties
Visual observation
(Corrosion and odour of putrefaction, rancidity or souring) ") |
- |
0 |
|
- |
| Cl-5.6 & 8, Table-1 (xii)("Keeping properties
Change in skinning") |
- |
0 |
|
- |
| Cl-5.6 & 8, Table-1 (xii)("Keeping properties
Degree of settling ") |
- |
0 |
|
- |
| Cl-5.6 & 8, Table-1 (xii)("Keeping properties
Observation of dried film ") |
- |
0 |
|
- |
| Cl-5.6 & 8, Table-1 (xii)("Keeping properties
Loss of mass resulting from Storage ") |
- |
0 |
|
- |
| Cl-5.7, Table-2 (i)(Consistency) |
- |
0 |
|
- |
| Cl-5.7, Table-2 (ii)(Hard dry, h, Max) |
- |
0 |
|
- |
| Cl-5.7, Table-2 (iii)(Non- volatile vehicle, percent, Min) |
- |
0 |
|
- |
| Cl-5.7, Table-2 (iv)(Wet opacity, m2 /10 l, Min) |
- |
0 |
|
- |
| Cl-4(The smell of the material shall not be objectionable during application) |
- |
0 |
|
- |
| Cl-5.1 (a)(Pigment) |
- |
0 |
|
- |
| Cl-5.1 (b)(Driers) |
- |
0 |
|
- |
| Cl-5.1.1 (a)("Zinc oxide content
Chromic anhydride content") |
- |
0 |
|
- |
| Cl-5.1.1 (b)(Synthetic red oxides of iron or Natural red oxides of iron or A mixture of both which shall correspond to red oxide, percent by mass) |
- |
0 |
|
- |
| Cl-5.1.1 (c)(Suitable extenders) |
- |
0 |
|
- |
| Cl-5.2(Material) |
- |
0 |
|
- |
| Cl-5.3(Compatibility with Thinner) |
- |
0 |
|
- |
| Cl-5.4(Freedom from Objectionable Impurities) |
- |
0 |
|
- |
| Cl-5.5(Lead Restriction) |
- |
0 |
|
- |
| Cl-5.6 & 8 Table-1 (i) (a)(Consistency) |
- |
0 |
|
- |
| Cl-5.6 & 8, Table-1 (i) (b)(Viscosity by ford cup No. 4 at 27±2°C) |
- |
0 |
|
- |
| Cl-5.6 & 8, Table-1 (ii)(Mass, in kg/10 1, Min) |
- |
0 |
|
- |
| Cl-5.6 & 8, Table-1 (iii)("Drying time, h, Max
a) Surface dry
b) Hard dry") |
- |
0 |
|
- |
| Cl-5.6 & 8, Table-1 (iv)(a) Finish) |
- |
0 |
|
- |
| Cl-5.6 & 8, Table-1 (iv)(b) Gloss 60° , Max) |
- |
0 |
|
- |
| Cl-5.6 & 8, Table-1 (v)(Fineness of grind, microns, Max) |
- |
0 |
|
- |
| Cl-5.6 & 8, Table-1 (vi)(Colour) |
- |
0 |
|
- |
| Cl-5.6 & 8,, Table-1 (vii) a)(Flexibility and adhesion: Bend test with 6.25mm dia mandrel and in type 1 apparatus) |
- |
0 |
|
- |
| Cl-5.6 & 8,, Table-1 (vii) b)(Flexibility and adhesion: Scratch hardness) |
- |
0 |
|
- |
| Cl-5.6 & 8, Table-1 (viii)(Flash point) |
- |
0 |
|
- |
| Cl-5.6 & 8,, Table-1 (ix)(Volume solids, percent) |
- |
0 |
|
- |
| Cl-5.6 & 8,, Table-1 (x) (a)(Resistance to humidity) |
- |
0 |
|
- |
| Cl-5.6 & 8, Table-1 (x) (b)("Resistance to sea
water (applicable for marine
paints only)") |
- |
0 |
|
- |
| Cl-5.6 & 8, Table-1 (x) (c)(Resistance to salt spray) |
- |
0 |
|
- |
| Cl-5.6 & 8, Table-1 (xi)(Accelerated storage stability test) |
- |
0 |
|
- |
| Cl-5.6 & 8, Table-1 (xii)("Keeping properties
Visual observation
(Corrosion and odour of putrefaction, rancidity or souring) ") |
- |
0 |
|
- |
| Cl-5.6 & 8, Table-1 (xii)("Keeping properties
Change in skinning") |
- |
0 |
|
- |
| Cl-5.6 & 8, Table-1 (xii)("Keeping properties
Degree of settling ") |
- |
0 |
|
- |
| Cl-5.6 & 8, Table-1 (xii)("Keeping properties
Observation of dried film ") |
- |
0 |
|
- |
| Cl-5.6 & 8, Table-1 (xii)("Keeping properties
Loss of mass resulting from Storage ") |
- |
0 |
|
- |
| Cl-5.7, Table-2 (i)(Consistency) |
- |
0 |
|
- |
| Cl-5.7, Table-2 (ii)(Hard dry, h, Max) |
- |
0 |
|
- |
| Cl-5.7, Table-2 (iii)(Non- volatile vehicle, percent, Min) |
- |
0 |
|
- |
| Cl-5.7, Table-2 (iv)(Wet opacity, m2 /10 l, Min) |
- |
0 |
|
- |
| Cl-4(The smell of the material shall not be objectionable during application) |
- |
0 |
|
- |
| Cl-5.1 (a)(Pigment) |
- |
0 |
|
- |
| Cl-5.1 (b)(Driers) |
- |
0 |
|
- |
| Cl-5.1.1 (a)("Zinc oxide content
Chromic anhydride content") |
- |
0 |
|
- |
| Cl-5.1.1 (b)(Synthetic red oxides of iron or Natural red oxides of iron or A mixture of both which shall correspond to red oxide, percent by mass) |
- |
0 |
|
- |
| Cl-5.1.1 (c)(Suitable extenders) |
- |
0 |
|
- |
| Cl-5.2(Material) |
- |
0 |
|
- |
| Cl-5.3(Compatibility with Thinner) |
- |
0 |
|
- |
| Cl-5.4(Freedom from Objectionable Impurities) |
- |
0 |
|
- |
| Cl-5.5(Lead Restriction) |
- |
0 |
|
- |
| Cl-5.6 & 8 Table-1 (i) (a)(Consistency) |
- |
0 |
|
- |
| Cl-5.6 & 8, Table-1 (i) (b)(Viscosity by ford cup No. 4 at 27±2°C) |
- |
0 |
|
- |
| Cl-5.6 & 8, Table-1 (ii)(Mass, in kg/10 1, Min) |
- |
0 |
|
- |
| Cl-5.6 & 8, Table-1 (iii)("Drying time, h, Max
a) Surface dry
b) Hard dry") |
- |
0 |
|
- |
| Cl-5.6 & 8, Table-1 (iv)(a) Finish) |
- |
0 |
|
- |
| Cl-5.6 & 8, Table-1 (iv)(b) Gloss 60° , Max) |
- |
0 |
|
- |
| Cl-5.6 & 8, Table-1 (v)(Fineness of grind, microns, Max) |
- |
0 |
|
- |
| Cl-5.6 & 8, Table-1 (vi)(Colour) |
- |
0 |
|
- |
| Cl-5.6 & 8,, Table-1 (vii) a)(Flexibility and adhesion: Bend test with 6.25mm dia mandrel and in type 1 apparatus) |
- |
0 |
|
- |
| Cl-5.6 & 8,, Table-1 (vii) b)(Flexibility and adhesion: Scratch hardness) |
- |
0 |
|
- |
| Cl-5.6 & 8, Table-1 (viii)(Flash point) |
- |
0 |
|
- |
| Cl-5.6 & 8,, Table-1 (ix)(Volume solids, percent) |
- |
0 |
|
- |
| Cl-5.6 & 8,, Table-1 (x) (a)(Resistance to humidity) |
- |
0 |
|
- |
| Cl-5.6 & 8, Table-1 (x) (b)("Resistance to sea
water (applicable for marine
paints only)") |
- |
0 |
|
- |
| Cl-5.6 & 8, Table-1 (x) (c)(Resistance to salt spray) |
- |
0 |
|
- |
| Cl-5.6 & 8, Table-1 (xi)(Accelerated storage stability test) |
- |
0 |
|
- |
| Cl-5.6 & 8, Table-1 (xii)("Keeping properties
Visual observation
(Corrosion and odour of putrefaction, rancidity or souring) ") |
- |
0 |
|
- |
| Cl-5.6 & 8, Table-1 (xii)("Keeping properties
Change in skinning") |
- |
0 |
|
- |
| Cl-5.6 & 8, Table-1 (xii)("Keeping properties
Degree of settling ") |
- |
0 |
|
- |
| Cl-5.6 & 8, Table-1 (xii)("Keeping properties
Observation of dried film ") |
- |
0 |
|
- |
| Cl-5.6 & 8, Table-1 (xii)("Keeping properties
Loss of mass resulting from Storage ") |
- |
0 |
|
- |
| Cl-5.7, Table-2 (i)(Consistency) |
- |
0 |
|
- |
| Cl-5.7, Table-2 (ii)(Hard dry, h, Max) |
- |
0 |
|
- |
| Cl-5.7, Table-2 (iii)(Non- volatile vehicle, percent, Min) |
- |
0 |
|
- |
| Cl-5.7, Table-2 (iv)(Wet opacity, m2 /10 l, Min) |
- |
0 |
|
- |
| Cl-4(The smell of the material shall not be objectionable during application) |
- |
0 |
|
- |
| Cl-5.1 (a)(Pigment) |
- |
0 |
|
- |
| Cl-5.1 (b)(Driers) |
- |
0 |
|
- |
| Cl-5.1.1 (a)("Zinc oxide content
Chromic anhydride content") |
- |
0 |
|
- |
| Cl-5.1.1 (b)(Synthetic red oxides of iron or Natural red oxides of iron or A mixture of both which shall correspond to red oxide, percent by mass) |
- |
0 |
|
- |
| Cl-5.1.1 (c)(Suitable extenders) |
- |
0 |
|
- |
| Cl-5.2(Material) |
- |
0 |
|
- |
| Cl-5.3(Compatibility with Thinner) |
- |
0 |
|
- |
| Cl-5.4(Freedom from Objectionable Impurities) |
- |
0 |
|
- |
| Cl-5.5(Lead Restriction) |
- |
0 |
|
- |
| Cl-5.6 & 8 Table-1 (i) (a)(Consistency) |
- |
0 |
|
- |
| Cl-5.6 & 8, Table-1 (i) (b)(Viscosity by ford cup No. 4 at 27±2°C) |
- |
0 |
|
- |
| Cl-5.6 & 8, Table-1 (ii)(Mass, in kg/10 1, Min) |
- |
0 |
|
- |
| Cl-5.6 & 8, Table-1 (iii)("Drying time, h, Max
a) Surface dry
b) Hard dry") |
- |
0 |
|
- |
| Cl-5.6 & 8, Table-1 (iv)(a) Finish) |
- |
0 |
|
- |
| Cl-5.6 & 8, Table-1 (iv)(b) Gloss 60° , Max) |
- |
0 |
|
- |
| Cl-5.6 & 8, Table-1 (v)(Fineness of grind, microns, Max) |
- |
0 |
|
- |
| Cl-5.6 & 8, Table-1 (vi)(Colour) |
- |
0 |
|
- |
| Cl-5.6 & 8,, Table-1 (vii) a)(Flexibility and adhesion: Bend test with 6.25mm dia mandrel and in type 1 apparatus) |
- |
0 |
|
- |
| Cl-5.6 & 8,, Table-1 (vii) b)(Flexibility and adhesion: Scratch hardness) |
- |
0 |
|
- |
| Cl-5.6 & 8, Table-1 (viii)(Flash point) |
- |
0 |
|
- |
| Cl-5.6 & 8,, Table-1 (ix)(Volume solids, percent) |
- |
0 |
|
- |
| Cl-5.6 & 8,, Table-1 (x) (a)(Resistance to humidity) |
- |
0 |
|
- |
| Cl-5.6 & 8, Table-1 (x) (b)("Resistance to sea
water (applicable for marine
paints only)") |
- |
0 |
|
- |
| Cl-5.6 & 8, Table-1 (x) (c)(Resistance to salt spray) |
- |
0 |
|
- |
| Cl-5.6 & 8, Table-1 (xi)(Accelerated storage stability test) |
- |
0 |
|
- |
| Cl-5.6 & 8, Table-1 (xii)("Keeping properties
Visual observation
(Corrosion and odour of putrefaction, rancidity or souring) ") |
- |
0 |
|
- |
| Cl-5.6 & 8, Table-1 (xii)("Keeping properties
Change in skinning") |
- |
0 |
|
- |
| Cl-5.6 & 8, Table-1 (xii)("Keeping properties
Degree of settling ") |
- |
0 |
|
- |
| Cl-5.6 & 8, Table-1 (xii)("Keeping properties
Observation of dried film ") |
- |
0 |
|
- |
| Cl-5.6 & 8, Table-1 (xii)("Keeping properties
Loss of mass resulting from Storage ") |
- |
0 |
|
- |
| Cl-5.7, Table-2 (i)(Consistency) |
- |
0 |
|
- |
| Cl-5.7, Table-2 (ii)(Hard dry, h, Max) |
- |
0 |
|
- |
| Cl-5.7, Table-2 (iii)(Non- volatile vehicle, percent, Min) |
- |
0 |
|
- |
| Cl-5.7, Table-2 (iv)(Wet opacity, m2 /10 l, Min) |
- |
0 |
|
- |
| Cl-4(The smell of the material shall not be objectionable during application) |
- |
0 |
|
- |
| Cl-5.1 (a)(Pigment) |
- |
0 |
|
- |
| Cl-5.1 (b)(Driers) |
- |
0 |
|
- |
| Cl-5.1.1 (a)("Zinc oxide content
Chromic anhydride content") |
- |
0 |
|
- |
| Cl-5.1.1 (b)(Synthetic red oxides of iron or Natural red oxides of iron or A mixture of both which shall correspond to red oxide, percent by mass) |
- |
0 |
|
- |
| Cl-5.1.1 (c)(Suitable extenders) |
- |
0 |
|
- |
| Cl-5.2(Material) |
- |
0 |
|
- |
| Cl-5.3(Compatibility with Thinner) |
- |
0 |
|
- |
| Cl-5.4(Freedom from Objectionable Impurities) |
- |
0 |
|
- |
| Cl-5.5(Lead Restriction) |
- |
0 |
|
- |
| Cl-5.6 & 8 Table-1 (i) (a)(Consistency) |
- |
0 |
|
- |
| Cl-5.6 & 8, Table-1 (i) (b)(Viscosity by ford cup No. 4 at 27±2°C) |
- |
0 |
|
- |
| Cl-5.6 & 8, Table-1 (ii)(Mass, in kg/10 1, Min) |
- |
0 |
|
- |
| Cl-5.6 & 8, Table-1 (iii)("Drying time, h, Max
a) Surface dry
b) Hard dry") |
- |
0 |
|
- |
| Cl-5.6 & 8, Table-1 (iv)(a) Finish) |
- |
0 |
|
- |
| Cl-5.6 & 8, Table-1 (iv)(b) Gloss 60° , Max) |
- |
0 |
|
- |
| Cl-5.6 & 8, Table-1 (v)(Fineness of grind, microns, Max) |
- |
0 |
|
- |
| Cl-5.6 & 8, Table-1 (vi)(Colour) |
- |
0 |
|
- |
| Cl-5.6 & 8,, Table-1 (vii) a)(Flexibility and adhesion: Bend test with 6.25mm dia mandrel and in type 1 apparatus) |
- |
0 |
|
- |
| Cl-5.6 & 8,, Table-1 (vii) b)(Flexibility and adhesion: Scratch hardness) |
- |
0 |
|
- |
| Cl-5.6 & 8, Table-1 (viii)(Flash point) |
- |
0 |
|
- |
| Cl-5.6 & 8,, Table-1 (ix)(Volume solids, percent) |
- |
0 |
|
- |
| Cl-5.6 & 8,, Table-1 (x) (a)(Resistance to humidity) |
- |
0 |
|
- |
| Cl-5.6 & 8, Table-1 (x) (b)("Resistance to sea
water (applicable for marine
paints only)") |
- |
0 |
|
- |
| Cl-5.6 & 8, Table-1 (x) (c)(Resistance to salt spray) |
- |
0 |
|
- |
| Cl-5.6 & 8, Table-1 (xi)(Accelerated storage stability test) |
- |
0 |
|
- |
| Cl-5.6 & 8, Table-1 (xii)("Keeping properties
Visual observation
(Corrosion and odour of putrefaction, rancidity or souring) ") |
- |
500 |
|
- |
| Cl-5.6 & 8, Table-1 (xii)("Keeping properties
Change in skinning") |
- |
0 |
|
- |
| Cl-5.6 & 8, Table-1 (xii)("Keeping properties
Degree of settling ") |
- |
0 |
|
- |
| Cl-5.6 & 8, Table-1 (xii)("Keeping properties
Observation of dried film ") |
- |
0 |
|
- |
| Cl-5.6 & 8, Table-1 (xii)("Keeping properties
Loss of mass resulting from Storage ") |
- |
0 |
|
( FOR KEEPING PROPERTIES THE TEST CHARGES WILL BE 500 ) |
| Cl-5.7, Table-2 (i)(Consistency) |
- |
0 |
|
- |
| Cl-5.7, Table-2 (ii)(Hard dry, h, Max) |
- |
0 |
|
- |
| Cl-5.7, Table-2 (iii)(Non- volatile vehicle, percent, Min) |
- |
0 |
|
- |
| Cl-5.7, Table-2 (iv)(Wet opacity, m2 /10 l, Min) |
- |
0 |
|
- |
| Cl-4(The smell of the material shall not be objectionable during application) |
- |
0 |
|
- |
| Cl-5.1 (a)(Pigment) |
- |
0 |
|
- |
| Cl-5.1 (b)(Driers) |
- |
0 |
|
- |
| Cl-5.1.1 (a)("Zinc oxide content
Chromic anhydride content") |
- |
0 |
|
- |
| Cl-5.1.1 (b)(Synthetic red oxides of iron or Natural red oxides of iron or A mixture of both which shall correspond to red oxide, percent by mass) |
- |
0 |
|
- |
| Cl-5.1.1 (c)(Suitable extenders) |
- |
0 |
|
- |
| Cl-5.2(Material) |
- |
0 |
|
- |
| Cl-5.3(Compatibility with Thinner) |
- |
0 |
|
- |
| Cl-5.4(Freedom from Objectionable Impurities) |
- |
0 |
|
- |
| Cl-5.5(Lead Restriction) |
- |
0 |
|
- |
| Cl-5.6 & 8 Table-1 (i) (a)(Consistency) |
- |
0 |
|
- |
| Cl-5.6 & 8, Table-1 (i) (b)(Viscosity by ford cup No. 4 at 27±2°C) |
- |
0 |
|
- |
| Cl-5.6 & 8, Table-1 (ii)(Mass, in kg/10 1, Min) |
- |
0 |
|
- |
| Cl-5.6 & 8, Table-1 (iii)("Drying time, h, Max
a) Surface dry
b) Hard dry") |
- |
0 |
|
- |
| Cl-5.6 & 8, Table-1 (iv)(a) Finish) |
- |
0 |
|
- |
| Cl-5.6 & 8, Table-1 (iv)(b) Gloss 60° , Max) |
- |
0 |
|
- |
| Cl-5.6 & 8, Table-1 (v)(Fineness of grind, microns, Max) |
- |
0 |
|
- |
| Cl-5.6 & 8, Table-1 (vi)(Colour) |
- |
0 |
|
- |
| Cl-5.6 & 8,, Table-1 (vii) a)(Flexibility and adhesion: Bend test with 6.25mm dia mandrel and in type 1 apparatus) |
- |
0 |
|
- |
| Cl-5.6 & 8,, Table-1 (vii) b)(Flexibility and adhesion: Scratch hardness) |
- |
0 |
|
- |
| Cl-5.6 & 8, Table-1 (viii)(Flash point) |
- |
0 |
|
- |
| Cl-5.6 & 8,, Table-1 (ix)(Volume solids, percent) |
- |
0 |
|
- |
| Cl-5.6 & 8,, Table-1 (x) (a)(Resistance to humidity) |
- |
0 |
|
- |
| Cl-5.6 & 8, Table-1 (x) (b)("Resistance to sea
water (applicable for marine
paints only)") |
- |
0 |
|
- |
| Cl-5.6 & 8, Table-1 (x) (c)(Resistance to salt spray) |
- |
0 |
|
- |
| Cl-5.6 & 8, Table-1 (xi)(Accelerated storage stability test) |
- |
0 |
|
- |
| Cl-5.6 & 8, Table-1 (xii)("Keeping properties
Visual observation
(Corrosion and odour of putrefaction, rancidity or souring) ") |
- |
0 |
|
- |
| Cl-5.6 & 8, Table-1 (xii)("Keeping properties
Change in skinning") |
- |
0 |
|
- |
| Cl-5.6 & 8, Table-1 (xii)("Keeping properties
Degree of settling ") |
- |
0 |
|
- |
| Cl-5.6 & 8, Table-1 (xii)("Keeping properties
Observation of dried film ") |
- |
0 |
|
- |
| Cl-5.6 & 8, Table-1 (xii)("Keeping properties
Loss of mass resulting from Storage ") |
- |
0 |
|
- |
| Cl-5.7, Table-2 (i)(Consistency) |
- |
0 |
|
- |
| Cl-5.7, Table-2 (ii)(Hard dry, h, Max) |
- |
0 |
|
- |
| Cl-5.7, Table-2 (iii)(Non- volatile vehicle, percent, Min) |
- |
0 |
|
- |
| Cl-5.7, Table-2 (iv)(Wet opacity, m2 /10 l, Min) |
- |
0 |
|
- |
|
31 Dec, 2026 |
- Included w.e.f. 26.09.2025
Exclusion: "Cl-4 (The smell of the material shall not be objectionable during application)
Cl-5.1.2 (volatile vehicle)
Cl-5.4 (Freedom from Objectionable Impurities)
" |
| 5385 |
Bharat Test House Pvt Ltd 1474 Sonipat Haryana
| 9135626
| IS 13450 : PART 2 : SEC 4 (2018) |
Medical electrical equipment: Part 2 particular requirements for the basic safety and essential performance: Sec 4 cardiac defibrillators (First Revision) |
Cardiac Defibrillators |
1090000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 201.4(General requirements) |
- |
10000 |
|
- |
| 201.5(General requirements for testing of ME EQUIPMENT) |
- |
45000 |
|
- |
| 201.6(Classification Of ME equipment and ME systems) |
- |
7500 |
|
- |
| 201.7(ME EQUIPMENT identification, marking and documents) |
- |
2500 |
|
- |
| 201.8(Protection against electrical HAZARDS from ME EQUIPMENT) |
- |
75000 |
|
- |
| 201.9(Protection against MECAHNICAL HAZARDS of ME EQUIPMENT and ME SYSTEMS) |
- |
75000 |
|
- |
| 201.10(Protection against unwanted and excessive radiation HAZARDS) |
- |
75000 |
|
- |
| 201.11(Protection against excessive temperatures and other HAZARDS) |
- |
75000 |
|
- |
| 201.12(Accuracy of controls and instruments and protection against hazardous outputs) |
- |
20000 |
|
- |
| 201.13(HAZARDOUS SITUATIONS and fault conditions) |
- |
75000 |
|
- |
| 201.14(PROGRAMMABLE ELECTRICAL MEDICAL SYSTEMS (PEMS)) |
- |
7500 |
|
- |
| 201.15(Construction of ME EQUIPMENT) |
- |
90000 |
|
- |
| 201.16(ME SYSTEMS) |
- |
7500 |
|
- |
| 201.17(Electromagnetic compatibility of ME equipment and ME systems) |
- |
300000 |
|
Facility for EMI/EMC available under 1668 (DIV-II) Location |
| 202(Electromagnetic compatibility-Requirement and tests) |
- |
300000 |
|
Facility for EMI/EMC available under 1668 (DIV-II) Location |
|
19 Mar, 2029 |
- Included w.e.f. 18.08.2025 |
| 5386 |
Classic Testing & Research Centre (B17), Noida
| 8180826
| IS 302 : Part 2 : Sec 30 (2007) |
Safety of household and similar electrical appliances: Part 2 particular requirements: Sec 30 room heaters (First Revision) |
- |
20000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl.6 (Classification) |
- |
500 |
|
- |
| Cl.6 (Classification) |
- |
500 |
|
- |
| Cl.7 & IS:302-1:2008(Marking and Instructions) |
- |
500 |
|
- |
| Cl.7 & IS:302-1:2008(Marking and Instructions) |
- |
500 |
|
- |
| Cl.7 & IS:302-1:2008(Marking and Instructions) |
- |
500 |
|
- |
| Cl.7 & IS:302-1:2008(Marking and Instructions) |
- |
500 |
|
- |
| Cl.7 & IS:302-1:2008(Marking and Instructions) |
- |
500 |
|
- |
| Cl.7 & IS:302-1:2008(Marking and Instructions) |
- |
500 |
|
- |
| Cl.7 & IS:302-1:2008(Marking and Instructions) |
- |
500 |
|
- |
| Cl.7 & IS:302-1:2008(Marking and Instructions) |
- |
500 |
|
- |
| Cl.7 & IS:302-1:2008(Marking and Instructions) |
- |
500 |
|
- |
| Cl.7(Marking and Instructions) |
- |
500 |
|
- |
| Cl.7(Marking and Instructions) |
- |
500 |
|
- |
| Cl.7(Marking and Instructions) |
- |
500 |
|
- |
| Cl.7.3(Marking and Instructions) |
- |
500 |
|
- |
| Cl.7.3(Marking and Instructions) |
- |
500 |
|
- |
| Cl.7.3(Marking and Instructions) |
- |
500 |
|
- |
| Cl.7.4(Marking and Instructions) |
- |
500 |
|
- |
| Cl.7.5(Marking and Instructions) |
- |
500 |
|
- |
| Cl.7.6 & IS:302-1:2008(Marking and Instructions) |
- |
500 |
|
- |
| Cl.7.8 of IS :302-1:2008(Marking and Instructions) |
- |
500 |
|
- |
| Cl.7.9 of IS :302-1:2008(Marking and Instructions) |
- |
500 |
|
- |
| Cl.7.10 of IS :302-1:2008(Marking and Instructions) |
- |
500 |
|
- |
| Cl.7.11 of IS :302-1:2008(Marking and Instructions) |
- |
500 |
|
- |
| Cl.7.12 & IS:302-1:2008(Marking and Instructions) |
- |
500 |
|
- |
| Cl.7.12 & IS:302-1:2008(Marking and Instructions) |
- |
500 |
|
- |
| Cl.7.12 & IS:302-1:2008(Marking and Instructions) |
- |
500 |
|
- |
| Cl.7.12 & IS:302-1:2008(Marking and Instructions) |
- |
500 |
|
- |
| Cl.7.12 & IS:302-1:2008(Marking and Instructions) |
- |
500 |
|
- |
| Cl.7.12 & IS:302-1:2008(Marking and Instructions) |
- |
500 |
|
- |
| Cl.7.12 & IS:302-1:2008(Marking and Instructions) |
- |
500 |
|
- |
| Cl.7.12 & IS:302-1:2008(Marking and Instructions) |
- |
500 |
|
- |
| Cl.7.12 & IS:302-1:2008(Marking and Instructions) |
- |
500 |
|
- |
| Cl.7.12 & IS:302-1:2008(Marking and Instructions) |
- |
500 |
|
- |
| Cl.7.12 & IS:302-1:2008(Marking and Instructions) |
- |
500 |
|
- |
| Cl.7.12 & IS:302-1:2008(Marking and Instructions) |
- |
500 |
|
- |
| Cl.7.12.1 & IS:302-1:2008(Marking and Instructions) |
- |
500 |
|
- |
| Cl.7.12.1 & IS:302-1:2008(Marking and Instructions) |
- |
500 |
|
- |
| Cl.7.12.1 & IS:302-1:2008(Marking and Instructions) |
- |
500 |
|
- |
| Cl.7.12.1 & IS:302-1:2008(Marking and Instructions) |
- |
500 |
|
- |
| Cl.7.12.1 & IS:302-1:2008(Marking and Instructions) |
- |
500 |
|
- |
| Cl.7.12.1 & IS:302-1:2008(Marking and Instructions) |
- |
500 |
|
- |
| Cl.7.12.1 & IS:302-1:2008(Marking and Instructions) |
- |
500 |
|
- |
| Cl.7.12.1 & IS:302-1:2008(Marking and Instructions) |
- |
500 |
|
- |
| Cl.7.12.1 & IS:302-1:2008(Marking and Instructions) |
- |
500 |
|
- |
| Cl.7.12.1 & IS:302-1:2008(Marking and Instructions) |
- |
500 |
|
- |
| Cl.7.12.1 & IS:302-1:2009(Marking and Instructions) |
- |
500 |
|
- |
| Cl.7.13 of IS 302-1:2008(Marking and Instructions) |
- |
500 |
|
- |
| Cl.7.14 of IS302-1:2008(Marking and Instructions) |
- |
500 |
|
- |
| Cl.7.14(Marking and Instructions) |
- |
500 |
|
- |
| Cl.7.14(Marking and Instructions) |
- |
500 |
|
- |
| Cl.7.15 of IS 302-1:2008(Marking and Instructions) |
- |
500 |
|
- |
| Cl.7.15 of IS 302-1:2008(Marking and Instructions) |
- |
500 |
|
- |
| Cl.7.15 of IS 302-1:2008(Marking and Instructions) |
- |
500 |
|
- |
| Cl.7.15 of IS 302-1:2008(Marking and Instructions) |
- |
500 |
|
- |
| Cl.7.101(Marking and Instructions) |
- |
500 |
|
- |
| Cl.8 & IS:302-1:2008(Protection Against Access to Live Parts) |
- |
2000 |
|
- |
| Cl.10 & IS:302-1:2008(Power Input and Current) |
- |
2000 |
|
- |
| Cl.11 & IS:302-1:2008(Heating) |
- |
2000 |
|
- |
| Cl.11 & IS:302-1:2008(Heating) |
- |
2000 |
|
- |
| Cl.11 & IS:302-1:2008(Heating) |
- |
2000 |
|
- |
| Cl.11 & IS:302-1:2008(Heating) |
- |
2000 |
|
- |
| Cl.11 & IS:302-1:2008(Heating) |
- |
2000 |
|
- |
| Cl.11 & IS:302-1:2008(Heating) |
- |
2000 |
|
- |
| Cl.11 & IS:302-1:2008(Heating) |
- |
2000 |
|
- |
| Cl.11 & IS:302-1:2008(Heating) |
- |
2000 |
|
- |
| Cl.11 & IS:302-1:2008(Heating) |
- |
2000 |
|
- |
| Cl.11 & IS:302-1:2008(Heating) |
- |
2000 |
|
- |
| Cl.11 & IS:302-1:2008(Heating) |
- |
2000 |
|
- |
| Cl.11 & IS:302-1:2008(Heating) |
- |
2000 |
|
- |
| Cl.11 & IS:302-1:2008(Heating) |
- |
2000 |
|
- |
| Cl.11 & IS:302-1:2008(Heating) |
- |
2000 |
|
- |
| Cl.11 & IS:302-1:2008(Heating) |
- |
2000 |
|
- |
| Cl.11 & IS:302-1:2008(Heating) |
- |
2000 |
|
- |
| Cl.11.8(Heating) |
- |
2000 |
|
- |
| Cl.11.8(Heating) |
- |
2000 |
|
- |
| Cl.11.8(Heating) |
- |
2000 |
|
- |
| Cl.13 & IS:302-1:2008(Leakage Current & Electric Strength at operating temp. ) |
- |
2200 |
|
- |
| Cl.13 & IS:302-1:2008(Leakage Current & Electric Strength at operating temp. ) |
- |
2200 |
|
- |
| Cl.14 & IS:302-1:2008(Transient Over Voltages) |
- |
1500 |
|
- |
| Cl.15 & IS: 302-1:2008(Moisture Resistance
) |
- |
2500 |
|
- |
| Cl.15.3 of IS 302-1:200(Moisture Resistance
) |
- |
2500 |
|
- |
| Cl.16 & IS:302-1:2008(Leakage Current & Electric Strength ) |
- |
2200 |
|
- |
| Cl.16 & IS:302-1:2008(Leakage Current & Electric Strength ) |
- |
2200 |
|
- |
| Cl.17 & IS:302-1:2008(Over load Protection of Transformers and Associated Circuits ) |
- |
2000 |
|
- |
| Cl.18 (Endurance. ) |
- |
2000 |
|
- |
| Cl.19 & IS:302-1:2008(Abnormal Operation.) |
- |
2000 |
|
- |
| Cl.19 & IS:302-1:2008(Abnormal Operation.) |
- |
2000 |
|
- |
| Cl.19 & IS:302-1:2008(Abnormal Operation.) |
- |
2000 |
|
- |
| Cl.19 & IS:302-1:2008(Abnormal Operation.) |
- |
2000 |
|
- |
| Cl.19.101(Abnormal Operation.) |
- |
2000 |
|
- |
| Cl.19.102(Abnormal Operation.) |
- |
2000 |
|
- |
| Cl.19.103(Abnormal Operation.) |
- |
2000 |
|
- |
| Cl.19.104(Abnormal Operation.) |
- |
2000 |
|
- |
| Cl.19.105(Abnormal Operation.) |
- |
2000 |
|
- |
| Cl.19.106(Abnormal Operation.) |
- |
2000 |
|
- |
| Table 8 of IS 302-1:2008(Abnormal Operation.) |
- |
2000 |
|
- |
| Cl.19.107(Abnormal Operation.) |
- |
2000 |
|
- |
| Cl.19.108(Abnormal Operation.) |
- |
2000 |
|
- |
| Cl.19.109(Abnormal Operation.) |
- |
2000 |
|
- |
| Cl.19.110(Abnormal Operation.) |
- |
2000 |
|
- |
| Cl.19.111(Abnormal Operation.) |
- |
2000 |
|
- |
| Cl.19.112(Abnormal Operation.) |
- |
2000 |
|
- |
| Cl.19.113(Abnormal Operation.) |
- |
2000 |
|
- |
| Cl.19.114(Abnormal Operation.) |
- |
2000 |
|
- |
| Cl.20 & IS:302-1:2008(Stability & Mechanical Hazards) |
- |
1500 |
|
- |
| Cl.21 & IS:302-1:2008)(Mechanical Strength.) |
- |
1500 |
|
- |
| Cl.21.2 of IS 302-1:2008(Mechanical Strength.) |
- |
1500 |
|
- |
| Cl.21.101 (Mechanical Strength.) |
- |
1500 |
|
- |
| Cl.21.102(Mechanical Strength.) |
- |
1500 |
|
- |
| Cl.21.103(Mechanical Strength.) |
- |
1500 |
|
- |
| Cl.22.1 of IS 302-1:2008(Construction) |
- |
2000 |
|
- |
| Cl.22.5 of IS 302-1:2008(Construction) |
- |
2000 |
|
- |
| Cl.22.6 of IS 302-1:2008(Construction) |
- |
2000 |
|
- |
| Cl.22.7 of IS 302-1:2008(Construction) |
- |
2000 |
|
- |
| Cl.22.8 of IS 302-1:2008(Construction) |
- |
2000 |
|
- |
| Cl.22.9 of IS 302-1:2008(Construction) |
- |
2000 |
|
- |
| Cl.22.11(Construction) |
- |
2000 |
|
- |
| Cl.22.12 of IS 302-1:2008(Construction) |
- |
2000 |
|
- |
| Cl.22.13 of IS 302-1:2008(Construction) |
- |
2000 |
|
- |
| Cl.22.14 of IS 302-1:2008(Construction) |
- |
2000 |
|
- |
| Cl.22.15 of IS 302-1:2008(Construction) |
- |
2000 |
|
- |
| Cl.22.18 of IS 302-1:2008(Construction) |
- |
2000 |
|
- |
| Cl.22.20 of IS 302-1:2008(Construction) |
- |
2000 |
|
- |
| Cl.22.21 of IS 302-1:2008(Construction) |
- |
2000 |
|
- |
| Cl.23 & IS:302-1:2008(Internal Wiring
) |
- |
1500 |
|
- |
| Cl.23.4 & Cl.29 of 302-1:2008(Internal Wiring
) |
- |
1500 |
|
- |
| Cl.23.5 of 302-1:2008(Internal Wiring
) |
- |
1500 |
|
- |
| Cl.23.7 of 302-1:2008(Internal Wiring
) |
- |
1500 |
|
- |
| C.23.7 of 302-1:2008(Internal Wiring
) |
- |
1500 |
|
- |
| Cl.24.1 of 302-1:2008(Component) |
- |
1000 |
|
- |
| Cl.24.1 of 302-1:2008(Component) |
- |
1000 |
|
- |
| Cl.24.1.3 (Component) |
- |
1000 |
|
- |
| Cl.24.1.3 (Component) |
- |
1000 |
|
- |
| Cl.24.1.3 (Component) |
- |
1000 |
|
- |
| Cl.24.1.3 (Component) |
- |
1000 |
|
- |
| C.24.1.4(Component) |
- |
1000 |
|
- |
| C.24.2 of 302-1:2008(Component) |
- |
1000 |
|
- |
| Cl.24.10(Component) |
- |
1000 |
|
- |
| Cl.25.1 of 302-1:2008(Supply Connection and External Flexible Cords ) |
- |
1000 |
|
- |
| Cl. 25.2 of IS 3021:2008(Supply Connection and External Flexible Cords ) |
- |
1000 |
|
- |
| Cl. 25.3 of IS 302-1:2008(Supply Connection and External Flexible Cords ) |
- |
1000 |
|
- |
| Cl. 25.4 of IS 302-1:2008(Supply Connection and External Flexible Cords ) |
- |
1000 |
|
- |
| Cl.25.5 of 302-1:2008(Supply Connection and External Flexible Cords ) |
- |
1000 |
|
- |
| Cl.25.6 of 302-1:2008(Supply Connection and External Flexible Cords ) |
- |
1000 |
|
- |
| Cl.25.7.(Supply Connection and External Flexible Cords ) |
- |
1000 |
|
- |
| Cl.25.8(Supply Connection and External Flexible Cords ) |
- |
1000 |
|
- |
| Cl. 25.9(Supply Connection and External Flexible Cords ) |
- |
1000 |
|
- |
| Cl.25.10 of 302-1:2008(Supply Connection and External Flexible Cords ) |
- |
1000 |
|
- |
| Cl. 25.11(Supply Connection and External Flexible Cords ) |
- |
1000 |
|
- |
| Cl. 25.12(Supply Connection and External Flexible Cords ) |
- |
1000 |
|
- |
| Cl. 25.13(Supply Connection and External Flexible Cords ) |
- |
1000 |
|
- |
| Cl.25.14 of IS 302-1:2008(Supply Connection and External Flexible Cords ) |
- |
1000 |
|
- |
| Cl.25.15 of IS 302-1:2008(Supply Connection and External Flexible Cords ) |
- |
1000 |
|
- |
| Cl.25.15 of IS 302-1:2008(Supply Connection and External Flexible Cords ) |
- |
1000 |
|
- |
| Cl.25.17 of IS 302-1:2008(Supply Connection and External Flexible Cords ) |
- |
1000 |
|
- |
| Cl.25.18(Supply Connection and External Flexible Cords ) |
- |
1000 |
|
- |
| Cl.25.20(Supply Connection and External Flexible Cords ) |
- |
1000 |
|
- |
| Cl.26.1 of IS 302-1:2008(Terminal for External Conductors
) |
- |
1000 |
|
- |
| Cl.26.10 of IS 302-1:2008(Terminal for External Conductors
) |
- |
1000 |
|
- |
| Cl.26.11 of IS 302-1:2008(Terminal for External Conductors
) |
- |
1000 |
|
- |
| Cl.27.1 of 302-1:2008(Provision for Earthing.) |
- |
1500 |
|
- |
| Cl.27.5 of 302-1:2008(Provision for Earthing.) |
- |
1500 |
|
- |
| Cl.28 of 302-1:2008(Screws and Connections.) |
- |
1000 |
|
- |
| Cl.29 & IS:302-1:2008(Clearances, Creepage Distances and Solid Insulation) |
- |
1500 |
|
- |
| Cl.29 & IS:302-1:2008(Clearances, Creepage Distances and Solid Insulation) |
- |
1500 |
|
- |
| Cl.30 & IS:302-1:2008(Resistance to Heat and Fire) |
- |
1500 |
|
- |
| Cl.30.2.2 of 302-1:2008(Resistance to Heat and Fire) |
- |
1500 |
|
- |
| Cl.31 & IS:302-1:2008(Resistance to Rusting.) |
- |
1500 |
|
- |
| Cl.32 & IS:302-1:2008(Radition,Toxicity and similar Hazards.) |
- |
1500 |
|
- |
| Cl.31 of IS:302-1:2008(Resistance to Rusting.) |
- |
1500 |
|
- |
| Cl.30.2 of 302-1:2008(Resistance to Heat and Fire : Resistance to fire) |
- |
1500 |
|
- |
| Cl.30.1 of IS:302-1:2008(Resistance to Heat and Fire: Resistance to heat. ) |
- |
1500 |
|
- |
| Cl.29.2 of IS:302-1:2008(Clearances, Creepage Distances and Solid Insulation : Creepage Distance) |
- |
1500 |
|
- |
| Cl.29.1 of IS:302-1:2008(Clearances, Creepage Distances and Solid Insulation : Clearance ) |
- |
1500 |
|
- |
| Cl.28 of 302-1:2008(Screws and Connections.) |
- |
1500 |
|
- |
| Cl.27.5 of 302-1:2008(Provision for Earthing : ECR) |
- |
1500 |
|
- |
| Cl.27.1 of 302-1:2008(Provision for Earthing ) |
- |
1500 |
|
- |
| Cl.26 of IS 302-1:2008(Terminal for External Conductors
) |
- |
1500 |
|
- |
| Cl.25.20 of 302-1:2008(Supply Connection and External Flexible Cords : Additional insulation ) |
- |
1500 |
|
- |
| Cl.25.18 of 302-1:2008(Supply Connection and External Flexible Cords : Arrangement of cord anchorages ) |
- |
1500 |
|
- |
| Cl.25.15 of IS 302-1:2008(Supply Connection and External Flexible Cords : Cord grip test - displacement) |
- |
1500 |
|
- |
| Cl.25.15 of IS 302-1:2008(Supply Connection and External Flexible Cords : Cord grip test - strain at terminals ) |
- |
1500 |
|
- |
| Cl. 25.13 of 302-1:2008(Supply Connection and External Flexible Cords : Inlet opening of supply cords ) |
- |
1500 |
|
- |
| Cl. 25.12 of 302-1:2008(Supply Connection and External Flexible Cords : Moulding of cords ) |
- |
1500 |
|
- |
| Cl.25.10 of 302-1:2008(Supply Connection and External Flexible Cords : Colour of earthing wire ) |
- |
1500 |
|
- |
| Cl. 25.9 of 302-1:2008(Supply Connection and External Flexible Cords : Contact with sharp edge ) |
- |
1500 |
|
- |
| Cl.25.8 of 302-1:2008(Supply Connection and External Flexible Cords : Resistance of supply wires ) |
- |
1500 |
|
- |
| Cl.25.7 of IS:302-2-30:2007(Supply Connection and External Flexible Cords : Supply cords material ) |
- |
1500 |
|
- |
| Cl.25.5 of 302-1:2008(Supply Connection and External Flexible Cords : Type of attachments ) |
- |
1500 |
|
- |
| Cl.25.1 of 302-1:2008(Supply Connection and External Flexible Cords : Means of connection ) |
- |
1500 |
|
- |
| Cl.24 of IS:302-2-30:2007(Component) |
- |
1000 |
|
- |
| Cl.23.7 of 302-1:2008(Internal Wiring : Colour of earting conductor
) |
- |
1000 |
|
- |
| Cl.23 of IS:302-1:2008(Internal Wiring
) |
- |
1000 |
|
- |
| Cl.22.106 of IS:302-2-30:2007(Construction : Checking of thermostats, timers or similar means for visibl glowing radiant heaters) |
- |
2000 |
|
- |
| Cl.22.106 of IS:302-2-30:2007(Construction : Checking of openings on the underside) |
- |
2000 |
|
- |
| Cl.22.102 & Cl 22.103 of IS:302-2-30:2007(Construction : Fireguard ) |
- |
2000 |
|
- |
| Cl.22.101 of IS:302-2-30:2007(Construction : Prevention to contact with heating element) |
- |
2000 |
|
- |
| Cl.22.24 of IS:302-2-30:2007(Construction : test of bare heating element) |
- |
2000 |
|
- |
| Cl.22.18 of IS 302-1:2008(Construction : Resistance to corrosion ) |
- |
2000 |
|
- |
| Cl.22.15 of IS 302-1:2008(Construction : Storage hooks for flexible cords) |
- |
2000 |
|
- |
| Cl.22.14 of IS 302-1:2008(Construction : ragged and sharp edges) |
- |
2000 |
|
- |
| Cl.22.13 of IS 302-1:2008(Construction : Position of handles ) |
- |
2000 |
|
- |
| Cl.22.12 of IS 302-1:2008(Construction : Fixing of Handle, knobs,grips,lever and similer parts ) |
- |
2000 |
|
- |
| Cl.22.11 of IS 302-1:2008(Construction : Fixing of non detachable parts ) |
- |
2000 |
|
- |
| Cl.22.7 of IS:302-2-30:2007(Construction : Pressure test of oil heater ) |
- |
2000.42 |
|
- |
| Cl.21.101 of IS:302-2-30:2007(Mechanical Strength : fire gaurd deformation test ) |
- |
1500 |
|
- |
| Cl.21.2 of IS 302-1:2008(Mechanical Strength : Pentration by sharp implementation ) |
- |
1500 |
|
- |
| Cl.21.1 of IS:302-1:2008)(Mechanical Strength : Rough handling ) |
- |
1500 |
|
- |
| Cl.20 of IS:302-2-30:2007(Stability of Mechanical Hazards) |
- |
1500 |
|
- |
| Cl.19.114 of IS:302-2-30:2007(Abnormal Operation : the temp. of the surface of the container for oil heaters ) |
- |
1500 |
|
- |
| Cl.19.112 of IS:302-2-30:2007(Abnormal Operation : Ignition of bleached cotton gauge) |
- |
1500 |
|
- |
| Cl.19.111 of IS:302-2-30:2007(Abnormal Operation : Ignition of flannelette for Visibly glowing heaters) |
- |
1500 |
|
- |
| Cl.19.110 of IS:302-2-30:2007(Abnormal Operation : operation against wall for visibly glowing radiant heaters ) |
- |
1500 |
|
- |
| Cl.19.109 of IS:302-2-30:2007(Abnormal Operation : operation against wall for fan heater ) |
- |
1500 |
|
- |
| Cl.19.106 of IS:302-2-30:2007(Abnormal Operation : Locked rotor of fan hetear ) |
- |
1500 |
|
- |
| Cl.19.103 , Cl 19.104 of IS:302-2-30:2007(Abnormal Operation : Operation after Covering by cotton) |
- |
1500 |
|
- |
| Cl.19 of IS:302-2-30:2007(Abnormal Operation : High Voltage ) |
- |
1500 |
|
- |
| Cl.19 of IS:302-2-30:2007(Abnormal Operation : temp rise of supply cord ) |
- |
1500 |
|
- |
| Cl.19 of IS:302-2-30:2007(Abnormal Operation : Temp rise of test corner ) |
- |
1500 |
|
- |
| Cl.19 of IS:302-1:2008(Abnormal Operation : Emission of molten or poisonous or ignitable gas) |
- |
1500 |
|
- |
| Cl.16 of IS:302-1:2008(Leakage current and Electric strength (After humidity): Electric Strentgh ) |
- |
1500 |
|
- |
| Cl.16 of IS:302-1:2008(Leakage current and Electric strength (After humidity): Leakage current ) |
- |
1500 |
|
- |
| Cl.15 of IS 302-1:2008(Moisture Resistance
) |
- |
1500 |
|
- |
| Cl.14 of IS:302-1:2008(Transient Over Voltages) |
- |
1500 |
|
- |
| Cl.13 of IS:302-1:2008(Leakage Current of Electric Strength at operating temp. ) |
- |
1500 |
|
- |
| Cl.13 of IS:302-1:2008(Leakage Current of Electric Strength at operating temp. ) |
- |
1500 |
|
- |
| Cl.11 of IS:302-2:30: 2007(Heating : Room temperature) |
- |
1500 |
|
- |
| Cl.11.8 of IS:302-2:30: 2007(Heating : For liquid filled radiators the temp. rise of the outer surface of the liquid container) |
- |
1500 |
|
- |
| Cl.11 of IS:302-2:30: 2007(Heating : Temperature rise in winding) |
- |
1500 |
|
- |
| Cl.11 of IS:302-2:30: 2007(Heating : Air-outlet grills) |
- |
1500 |
|
- |
| Cl.11 of IS:302-2:30: 2007(Heating : Surfaces of handles, knobs, grips and similar parts) |
- |
1500 |
|
- |
| Cl.11 of IS:302-2:30: 2007(Heating : Wooden supports, walls, ceiling and floor of the test corner) |
- |
1500 |
|
- |
| Cl.11 of IS:302-2:30: 2007(Heating : PVC Insulation ) |
- |
1500 |
|
- |
| Cl.10 of IS:302-1:2008(Power Input and Current) |
- |
1000 |
|
- |
| Cl.8 of IS:302-1:2008(Protection Against Access to Live Parts) |
- |
1000 |
|
- |
| Cl.7.101 of IS:302-2:30: 2007(Marking and Instructions : standard mark. ) |
- |
500 |
|
- |
| Cl.7.15 of IS 302-1:2008(Marking and Instructions : Visibility of marking concerning covering) |
- |
500 |
|
- |
| Cl.7.15 of IS 302-1:2008(Marking and Instructions : discernibility from the out side ) |
- |
500 |
|
- |
| Cl.7.14 of IS:302-2:30: 2007(Marking and Instructions : Height of “Do not cover”) |
- |
500 |
|
- |
| Cl.7.14 of IS:302-2:30: 2007(Marking and Instructions : height of symbol) |
- |
500 |
|
- |
| Cl.7.14 of IS302-1:2008(Marking and Instructions : Legibility and durability ) |
- |
500 |
|
- |
| Cl.7.13 of IS 302-1:2008(Marking and Instructions : Languge of instruction and texts ) |
- |
500 |
|
- |
| Cl.7.11 of IS :302-1:2008(Marking and Instructions : Controls ) |
- |
500 |
|
- |
| Cl.7.9 of IS :302-1:2008(Marking and Instructions : switches ) |
- |
500 |
|
- |
| Cl.7.8 of IS :302-1:2008(Marking and Instructions : terminals ) |
- |
500 |
|
- |
| Cl.7.6 of IS:302-1:2008(Marking and Instructions : Symbols ) |
- |
500 |
|
- |
| Cl.7.5 of IS:302-1:2008(Marking and Instructions : upper of lower limit of the rated power input ) |
- |
500 |
|
- |
| Cl 7.1 & Cl.7.6 of IS:302-2:30: 2007(Marking and Instructions : Do not cover ) |
- |
500 |
|
- |
| Cl.7.1 of IS:302-1:2008(Marking and Instructions : Country of manufacture ) |
- |
500 |
|
- |
| Cl.7.1 of IS:302-1:2008(Marking and Instructions : Symbol for Class-II ) |
- |
500 |
|
- |
| Cl.7.1 of IS:302-1:2008(Marking and Instructions : Model or type ) |
- |
500 |
|
- |
| Cl.7.1 of IS:302-1:2008(Marking and Instructions : Name , trade-mark or identification mark of the manufacturer ) |
- |
500 |
|
- |
| Cl.7.1 of IS:302-1:2008(Marking and Instructions : rated power input ) |
- |
500 |
|
- |
| Cl.7.1 of IS:302-1:2008(Marking and Instructions : Nature of supply ) |
- |
500 |
|
- |
| Cl.7.1 of IS:302-1:2008(Marking and Instructions : Rated Voltage ) |
- |
500 |
|
- |
| 19.11.4.1(Electrostatic discharges) |
- |
2500 |
|
- |
| 19.11.4.3(Fast transient bursts) |
- |
2500 |
|
- |
| 19.11.4.4(Surge immunity test) |
- |
2500 |
|
- |
| 19.11.4.6(Class 3 Voltage dips and interruptions) |
- |
2500 |
|
- |
| 19.11.4.7(Harmonics) |
- |
2500 |
|
- |
|
15 Oct, 2027 |
- Included w.e.f 11.07.2025
Exclusion: Cl 19.11.4.2(Radiated fields), Cl 19.11.4.5(Injected Current) |
| 5387 |
JBS TESTING SOLUTIONS PVT LTD (27), JALANDHAR
| 9164606
| IS 2185 : Part 2 (1983) |
Specification for concrete masonry units: Part 2 hollow and solid lightweight concrete blocks (First Revision) |
- |
15000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 8.7(Moisture Movement) |
- |
1500 |
|
- |
| 8.6(Drying shrinkage) |
- |
3500 |
|
- |
| 8.5, Table 1(Water Absorption) |
- |
2000 |
|
- |
| 8.4, Table 1(Compressive strength) |
- |
3500 |
|
- |
| 8.3(Block Density) |
- |
1500 |
|
- |
| 3.2.5(Thickness of Web) |
- |
3000 |
|
For dimensional and other qualitative test |
| 3.2.5(Face Shell Thickness) |
- |
3000 |
|
For dimensional and other qualitative test |
| 3.2(Width) |
- |
3000 |
|
For dimensional and other qualitative test |
| 3.2(Height) |
- |
3000 |
|
For dimensional and other qualitative test |
| 3.2(Length) |
- |
3000 |
|
For dimensional and other qualitative test |
| 8.1(General) |
- |
3000 |
|
For dimensional and other qualitative test |
| 8.2(Deimension (Length)) |
- |
3000 |
|
For dimensional and other qualitative test |
| 8.2(Deimension (Height)) |
- |
3000 |
|
For dimensional and other qualitative test |
| 8.2(Deimension (Width)) |
- |
3000 |
|
For dimensional and other qualitative test |
| 8.3(Block Density) |
- |
1500 |
|
For block density test |
| 8.4(Compressive Strength) |
- |
3500 |
|
For compressive strength test |
| 8.5(Water Absorption) |
- |
2000 |
|
For water absorption test |
| 8.6(Drying Shrinkage) |
- |
3500 |
|
For drying shrinkage test |
| 8.7(Moisture Movement) |
- |
1500 |
|
For moisture movement test |
|
- |
- Included w.e.f.30.06.2025 |
| 5388 |
JBS TESTING SOLUTIONS PVT LTD (27), JALANDHAR
| 9164606
| IS 2185 : Part 1 (2005) |
Concrete masonry units - Specification: Part 1 hollow and solid concrete blocks (Third Revision) |
- |
15000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 9.1(PHYSICAL REQUIREMENTS-General) |
- |
3000 |
|
For dimensional and other qualitative test |
| 9.2 & 4.2(PHYSICAL REQUIREMENTS-Nominal Dimensions 1.Length 2.Hight 3. Width) |
- |
3000 |
|
For dimensional and other qualitative test |
| 9.2 & 4.2.3(Nominal Dimensions-variation in the length of units ) |
- |
3000 |
|
For dimensional and other qualitative test |
| 9.2 & 4.2.3(Nominal Dimensions -variation in height and width of units ) |
- |
3000 |
|
For dimensional and other qualitative test |
| 9.2 & 4.2.4, Table-1(Nominal Dimensions-thickness of
the face shell) |
- |
3000 |
|
For dimensional and other qualitative test |
| 9.2 & 4.2.4, Table-1(Nominal Dimensions-thickness of
the Web shell) |
- |
3000 |
|
For dimensional and other qualitative test |
| 9.3 & 5.1 & 5.2 Table 2(PHYSICAL REQUIREMENTS-Blocks Density - 1.Hollow (Open and Closed Cavity) Concrete Block- Grade Aor Grade B 2.Solid Concrete Block — Grade C) |
- |
1500 |
|
For block density test |
| 9.4- Table 2(PHYSICAL REQUIREMENTS - Compressive Strength 1.Minimum Average Compressive Strength of Units 2.Minimum Average Compressive Strength of Individual Unit) |
- |
3500 |
|
For compressive strength test |
| 9.5(PHYSICAL REQUIREMENTS -Water Absorption) |
- |
2000 |
|
For water absorption test |
| 9.6(PHYSICAL REQUIREMENTS -Drying Shrinkage) |
- |
3500 |
|
For drying shrinkage test |
| 9.7(PHYSICAL REQUIREMENTS -Moisture Movement) |
- |
1500 |
|
For moisture movement test |
| 15(Marking) |
- |
3000 |
|
For dimensional and other qualitative test |
|
- |
- Included w.e.f.30.06.2025 |
| 5389 |
Hi Physix Laboratory India Private Limited, Pune
| 7126926
| IS 4250 (2025) |
Electric Food-Mixers (Liquidizers and Grinders) and Centrifugal Juicers � Specification ( Second Revision ) |
- |
40000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl-4(General Requirements) |
- |
0 |
|
- |
| Cl-5(General Conditions for the tests) |
- |
0 |
|
- |
| Cl-6(Classification) |
- |
0 |
|
- |
| Cl-7(Marking) |
- |
1000 |
|
- |
| Cl-8(Safety Requirements) |
- |
20000 |
|
- |
| Cl-9(Endurance fpr motor and base assembly) |
- |
10000 |
|
- |
| Cl-10.2("Grinding Coffee (for Machines that Have a
Dry Grinding Arrangement)") |
- |
2000 |
|
- |
| Cl-10.3(Whisking Egg Whites (for Machines that have Whisking Egg Arrangement)) |
- |
1000 |
|
- |
| Cl-10.4(Idli Batter) |
- |
1000 |
|
- |
| Cl-10.5(Operational Tests for Juicers) |
- |
2000 |
|
- |
| Cl-11(Temperature Withstand Test for Bowl) |
- |
1000 |
|
- |
| Cl-12.1(Test for Switches) |
- |
1000 |
|
- |
| Cl-13(Strength of Assembly) |
- |
1000 |
|
- |
| Cl-14.2, 14.3 Table-2 (i)(Protection against access to live parts) |
- |
1000 |
|
- |
| Cl-14.2, Table-2 (ii)(Power input and current) |
- |
2000 |
|
- |
| Cl-14.2, 14.3 Table-2 (iii)(Leakage current and electric strength at operating temperature) |
- |
1000 |
|
- |
| Cl-14.2, Table-2 (iv)(Moisture resistance) |
- |
1000 |
|
- |
| Cl-14.2, Table-2 (v)(Leakage current and electric strength) |
- |
1000 |
|
- |
| Cl-14.2, 14.3 Table-2 (vi)(Provision for earthing) |
- |
1000 |
|
- |
| Cl-19.11.4.1(Electrostatic discharges) |
- |
5000 |
|
if applicable (If EMI/EMC (Cl.19.11.4.1 to Cl.19.11.4.7) testing is applicable then Rs. 55000 will be charged extra) |
| Cl-19.11.4.2(Radiated fields) |
- |
20000 |
|
if applicable |
| Cl-19.11.4.3(Fast transient bursts) |
- |
5000 |
|
if applicable |
| Cl-19.11.4.4(Surge immunity test) |
- |
5000 |
|
if applicable |
| Cl-19.11.4.5(Immunity to conducted discharges) |
- |
10000 |
|
if applicable |
| Cl-19.11.4.6(Class 3 Voltage dips and interruptions) |
- |
5000 |
|
if applicable |
| Cl-19.11.4.7(Harmonics) |
- |
5000 |
|
if applicable |
|
20 Jun, 2028 |
- Included w.e.f 28.07.2025
Exclusion: Cl 22.32 (Construction) Rubber parts oxygen bomb test, Cl 24 (Components) Components testing |
| 5390 |
Atharva Laboratories Pvt. Ltd. (C-54), Noida
| 8165026
| IS 14544 (2022) |
LEATHER SAFETY AND PROTECTIVE FOOTWEAR WITH DIRECT MOULDED POLYVINYL CHLORIDE PVC SOLE - SPECIFICATION First Revision |
- |
40000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 8.1(Cl. No. 5.10 of IC 15298(P-1):2015) |
- |
1500 |
|
- |
| 8.2(Cl. No. 5.10 of IC 15298(P-1):2015) |
- |
1500 |
|
- |
| Cl-6.2(Design) |
- |
150 |
|
- |
| Cl-6.3(Size and Fitting) |
- |
200 |
|
- |
| Cl-6.4(Height of Upper) |
- |
200 |
|
- |
| Cl-6.5.1(Whole Footwear-Construction) |
- |
200 |
|
- |
| Cl-6.5.2(Whole Footwear-Ergonomic Feature) |
- |
500 |
|
- |
| Cl-6.5.3(Whole Footwear-Upper – Outsole Bond Strength) |
- |
800 |
|
- |
| Cl-6.5.4(Whole Footwear- Slip Resistance) |
- |
1500 |
|
- |
| Cl-6.5.5(Whole Footwear- Resistance to Fuel Oil) |
- |
2000 |
|
- |
| Cl-6.5.6(Whole Footwear- Impact Resistance) |
- |
1200 |
|
- |
| Cl-6.5.7(Whole Footwear- Compression Resistance) |
- |
1200 |
|
- |
| Cl-6.5.8(Whole Footwear- Resistance to Corrosion) |
- |
2000 |
|
- |
| Cl-6.6.2(Upper- Material) |
- |
200 |
|
- |
| Cl-6.6.3(Upper-Tear Strength) |
- |
800 |
|
- |
| Cl-6.6.4(Upper- Tensile strength) |
- |
800 |
|
- |
| Cl-6.6.5(Upper- Water Vapour Permeability and Coefficient) |
- |
1000 |
|
- |
| Cl-6.7.1(Vamp and quarter lining-Material) |
- |
200 |
|
- |
| Cl-6.7.2(Vamp and quarter lining-Tear strength) |
- |
800 |
|
- |
| Cl-6.7.3(Vamp and quarter lining-Abrasion resistance) |
- |
1200 |
|
- |
| Cl-6.7.4(Vamp and quarter lining-Water vapour permeability and coefficient) |
- |
1000 |
|
- |
| Cl-6.8(Toecaps -Whole toecap) |
- |
3000 |
|
- |
| Cl-6.9.1(Insole- Material) |
- |
200 |
|
- |
| Cl-6.9.2(Insole-Thickness) |
- |
200 |
|
- |
| Cl-6.9.3(Insole- Abrasion resistance) |
- |
600 |
|
- |
| Cl-6.9.4(Insole- Water absorption and desorption) |
- |
1000 |
|
- |
| Cl-6.10(Insocks-Thickness) |
- |
200 |
|
- |
| Cl-6.10.1(Insocks-Material) |
- |
200 |
|
- |
| Cl-6.10.2(Insocks-Abrasion resistance) |
- |
1200 |
|
- |
| Cl-6.10.3(Insocks-Water absorption and desorption) |
- |
1000 |
|
- |
| Cl-6.11(Stiffener) |
- |
3000 |
|
- |
| Cl-6.12(Tongue -Material) |
- |
800 |
|
- |
| Cl-6.13(Closing thread-- Properties) |
- |
1000 |
|
- |
| Cl-6.14.1(Outsole-Material) |
- |
200 |
|
- |
| Cl-6.14.2, 6.14.3 & 6.14.4(Outsole-Thickness, cleat area and cleat height) |
- |
200 |
|
- |
| Cl-6.14.5(Outsole-Tear strength) |
- |
800 |
|
- |
| Cl-6.14.6(Outsole-Abrasion resistance) |
- |
1000 |
|
- |
| Cl-6.14.7(Outsole-Flexing resistance) |
- |
1000 |
|
- |
| Cl-6.14.8(Outsole-Interlayer bond strength) |
- |
800 |
|
- |
| Cl-6.15.1(Laces-Material) |
- |
200 |
|
- |
| Cl-6.15.2(Laces-Colour Fastness) |
- |
1000 |
|
- |
| Cl-6.15.3(Laces-Abrasion Resistance) |
- |
800 |
|
- |
| Cl-6.15.4(Laces-Breaking load) |
- |
800 |
|
- |
| Cl-7.1, Table 1 of IS 17011 (i)(Allergenic and carcinogenic disperse dyes) |
- |
3000 |
|
Chemical package charges- 25000 |
| Cl-7.2(PVC outsole) |
- |
3000 |
|
- |
| Cl-8.3(Cold insulation of Sole) |
- |
1000 |
|
- |
| Cl-8.4(Heat insulation of Sole) |
- |
1000 |
|
- |
| Cl-10(Marking) |
- |
200 |
|
- |
| cL-7.1, Table no 1 of IS 17011 (ii)(Aromatic amines released from Azo dyes (each individual amine)) |
- |
3000 |
|
- |
| Cl-7.1 Table no 1 of IS 17011 (iii)(Aromatic amines released from Azo dyes (each individual amine)) |
- |
3000 |
|
- |
| Cl-7.1, Table no 1 of IS 17011 (iv)(Chromium (VI)) |
- |
3000 |
|
- |
| Cl-7.1, Table no 1 of IS 17011 (v)(Dimethyl fumarate (DMFU)) |
- |
3000 |
|
- |
| Cl-7.1, Table no 1 of IS 17011 (vi)(Formaldehyde (free or released by partial hydrolysis)) |
- |
3000 |
|
- |
| Cl-7.1, Table no 1 of IS 17011 (vii)(Formaldehyde) |
- |
3000 |
|
- |
| Cl-7.1, Table no 1 of IS 17011 (viii)(Organotin compounds) |
- |
3000 |
|
- |
| Cl-7.1, Table no 1 of IS 17011 (ix)(PCP-TeCP-TriCP polychlorophenols) |
- |
3000 |
|
- |
| Cl-7.1, Table no 1 of IS 17011 (x)(pH) |
- |
800 |
|
- |
| Cl-7.1, Table no 1 of IS 17011 (xi)(Phthalates (each individual phthalate)) |
- |
3000 |
|
- |
| Cl-7.1, Table no 1 of IS 17011 (xii)(Nickel, on skin contact) |
- |
3000 |
|
- |
|
- |
- Included w.e.f. 18.08.2025 |
| 5391 |
SHRI KRISHNA TEST HOUSE PVT LTD (142)
| 8185606
| IS 16218 (2014) |
Forks - Specification |
ALL |
15000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 3.1(food grade stainless steel.) |
- |
15000 |
|
- |
| 3.2 (i)(Brass as parent material) |
- |
15000 |
|
- |
| 3.2(ii)(Brass plated with pure silver) |
- |
15000 |
|
- |
| 3.3(Plastic handle) |
- |
15000 |
|
- |
| 4(Shapes and Dimensions) |
- |
15000 |
|
- |
| 5(Manufacture) |
- |
15000 |
|
- |
| 6.1(Workmanship) |
- |
15000 |
|
- |
| 6.2(Finish) |
- |
15000 |
|
- |
| 9(Marking) |
- |
15000 |
|
- |
| 10(Packing) |
- |
15000 |
|
- |
|
13 May, 2028 |
- Included w.e.f 03.07.2025 |
| 5392 |
SHRI KRISHNA TEST HOUSE PVT LTD (142)
| 8185606
| IS 16286 (2014) |
Spoons - Specification |
all |
15000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 3.1(food grade stainless steel.) |
- |
15000 |
|
- |
| 3.2 (i)(Brass as parent material) |
- |
15000 |
|
- |
| 3.2(ii)(Brass plated with pure silver) |
- |
15000 |
|
- |
| 3.3(Plastic handle) |
- |
15000 |
|
- |
| 4(Shapes and Dimensions) |
- |
15000 |
|
- |
| 5.1(Manufacture) |
- |
15000 |
|
- |
| 5.2(Workmanship) |
- |
15000 |
|
- |
| 5.3(Finish) |
- |
15000 |
|
- |
| 8(Marking) |
- |
15000 |
|
- |
| 9(Packing) |
- |
15000 |
|
- |
| Cl-6.1(Staining Test) |
- |
15000 |
|
- |
| Cl-6.2(Bending Test) |
- |
15000 |
|
- |
| Cl-6.3(Load Test) |
- |
15000 |
|
- |
| Cl-6.4.1(Boiling) |
- |
15000 |
|
- |
| Cl-6.4.2(Impact) |
- |
15000 |
|
- |
| Cl-6.4.3(Staining) |
- |
15000 |
|
- |
|
13 May, 2028 |
- Included w.e.f 03.07.2025 |
| 5393 |
ALPHA TEST HOUSE PVT LTD, BAHADURGARH
| 8185306
| IS 617 (2024) |
Aluminium and Aluminium Alloys Ingots for Remelting and Castings for General Engineering Purposes â Specification (Fourth Revision) |
ALL |
14900 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl-6.1, Table-1(Si) |
- |
14900 |
|
- |
| Cl-6.1, Table-1(Fe) |
- |
14900 |
|
- |
| Cl-6.1, Table-1(Cu) |
- |
14900 |
|
- |
| Cl-6.1, Table-1(Mn) |
- |
14900 |
|
- |
| Cl-6.1, Table-1(Mg) |
- |
14900 |
|
- |
| Cl-6.1, Table-1(Cr) |
- |
14900 |
|
- |
| Cl-6.1, Table-1(Ni) |
- |
14900 |
|
- |
| Cl-6.1, Table-1(Zn) |
- |
14900 |
|
- |
| Cl-6.1, Table-1(Pb) |
- |
14900 |
|
- |
| Cl-6.1, Table-1(Sn) |
- |
14900 |
|
- |
| Cl-6.1, Table-1(Ti) |
- |
14900 |
|
- |
| Cl-6.1, Table-1(Others elements Each) |
- |
14900 |
|
- |
| Cl-6.1, Table-1(Others elements Total) |
- |
14900 |
|
- |
| Cl-6.1, Table-1(Aluminium) |
- |
14900 |
|
- |
| Cl-6.2(The chemical analysis) |
- |
14900 |
|
- |
| Cl-7.1, Table-2(Sand-Cast Alloys- Tensile Strength) |
- |
14900 |
|
- |
| Cl-7.1, Table-2(Sand-Cast Alloys- Proof Stress) |
- |
14900 |
|
- |
| Cl-7.1, Table-2(Sand-Cast Alloys- Elongation) |
- |
14900 |
|
- |
| Cl-7.1, Table-2(Sand-Cast Alloys- Brinell Hardness HBW) |
- |
14900 |
|
- |
| Cl-7.1, Table-3(Chill Cast Alloys- Tensile Strength) |
- |
14900 |
|
- |
| Cl-7.1, Table-3(Chill Cast Alloys- Proof Stress) |
- |
14900 |
|
- |
| Cl-7.1, Table-3(Chill Cast Alloys- Elongation) |
- |
14900 |
|
- |
| Cl-7.1, Table-3(Chill Cast Alloys- Brinell Hardness HBW) |
- |
14900 |
|
- |
| Cl-7.1, Table-4(Investment-Cast Alloys- Tensile Strength) |
- |
14900 |
|
- |
| Cl-7.1, Table-4(Investment-Cast Alloys- Proof Stress) |
- |
14900 |
|
- |
| Cl-7.1, Table-4(Investment-Cast Alloys- Elongation) |
- |
14900 |
|
- |
| Cl-7.1, Table-4(Investment-Cast Alloys-Brinell Hardness) |
- |
14900 |
|
- |
| Cl-7.2(Tensile Tests) |
- |
14900 |
|
- |
| Cl-7.3(Test Pieces) |
- |
14900 |
|
- |
| Cl-7.4(Hardness) |
- |
14900 |
|
- |
| Cl-8(Freedom from Defects) |
- |
14900 |
|
- |
| Cl-11(RETEST) |
- |
14900 |
|
- |
| Cl-13(Marking) |
- |
14900 |
|
- |
| Cl. 6(Silicon) |
- |
14900 |
|
- |
| Cl. 6(Iron) |
- |
14900 |
|
- |
| Cl. 6(Copper) |
- |
14900 |
|
- |
| Cl. 6(Manganese) |
- |
14900 |
|
- |
| Cl. 6(Magnesium) |
- |
14900 |
|
- |
| Cl. 6(Chromium) |
- |
14900 |
|
- |
| Cl. 6(Nickel) |
- |
14900 |
|
- |
| Cl. 6(Zinc) |
- |
14900 |
|
- |
| Cl. 6(Lead) |
- |
14900 |
|
- |
| Cl. 6(Tin) |
- |
14900 |
|
- |
| Cl. 6(Titanium) |
- |
14900 |
|
- |
| Cl. 6(Others Element Each) |
- |
14900 |
|
- |
| Cl. 6(Others Element Total) |
- |
14900 |
|
- |
| Cl. 6(Aluminium) |
- |
14900 |
|
- |
| Cl. 6(Silver) |
- |
14900 |
|
- |
| Cl. 6(Zirconium) |
- |
14900 |
|
- |
| Cl. 6(Titanium+Zirconium) |
- |
14900 |
|
- |
| Cl. 6(Antimony) |
- |
14900 |
|
- |
| Cl. 6(Cobalt) |
- |
14900 |
|
- |
| Cl. 6(Antimony+Cobalt) |
- |
14900 |
|
- |
| Cl. 6(Beryllium) |
- |
14900 |
|
- |
| 10(Pressure Test) |
- |
14900 |
|
- |
|
08 May, 2028 |
- Included w.e.f 02.07.2025 |
| 5394 |
EMC Testing and Compliance LLP, Gurugram
| 8141526
| IS 302 : Part 2 : SEC 31 (2009) |
Safety of household and similar electrical appliances: Part 2 particular requirements: Sec 31 range hoods |
- |
50000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Clause No - 5(GENERAL CONDITIONS FOR THE TESTS) |
- |
2000 |
|
- |
| Clause No - 5.18(linear and angular dimension) |
- |
2000 |
|
- |
| Clause No - 6.2(harmfull ingress of water) |
- |
2000 |
|
- |
| Clause No - 8.1.1("PROTECTION AGAINST ACCESS TO LIVE
PART- test probe B") |
- |
2000 |
|
- |
| Clause No - 8.1.2("PROTECTION AGAINST ACCESS TO LIVE
PART - test probe 13") |
- |
2000 |
|
- |
| Clause No - 8.2(Addition) |
- |
2000 |
|
- |
| Clause No - 10.1, Table No. -1(power input deviation) |
- |
2000 |
|
- |
| Clause No - 13.3("LEAKAGE CURRENT AND ELECTRIC
STRENGTH AT OPERATING TEMPERATURE") |
- |
2000 |
|
- |
| Clause No - 13.3,Table No.- 4(voltage for electrical strength) |
- |
2000 |
|
- |
| Clause No - 14(Impulse test voltage) |
- |
2000 |
|
- |
| Clause No - 15.1.1(MOISTURE RESISTANCE) |
- |
3000 |
|
- |
| Clause No -19.7(test is repeated with the capacitor short circuited) |
- |
2000 |
|
- |
| Clause No -21.1(Mechanical strength) |
- |
2000 |
|
- |
| Clause No -22.1(construction) |
- |
2000 |
|
- |
| Clause No -22.11(push force applied) |
- |
2000 |
|
- |
| Clause No -24.1.2(safety isolating transformer) |
- |
2000 |
|
- |
| Clause No -24.1.3(for switches) |
- |
2000 |
|
- |
| Clause No -24.1.4(for automatic control) |
- |
2000 |
|
- |
| Clause No -24.1.5(for innterconnection couplers) |
- |
2000 |
|
- |
| Clause No -24.4(plug and socket) |
- |
2000 |
|
- |
| Clause No -25.8, Table no -11(conductor resistance) |
- |
2000 |
|
- |
| Clause No -25.5(dimension for pins) |
- |
2000 |
|
- |
| Clause No -27.6(for circuit board) |
- |
2000 |
|
- |
| Clause No -29.2(comparative tracking index) |
- |
2000 |
|
- |
| Clause No -29.3.3(dry heat test) |
- |
2000 |
|
- |
| Clause No -30.2.1(glow wire test) |
- |
2000 |
|
- |
| Clause No -30.101("incorporate combustible
material") |
- |
2000 |
|
- |
| 15(MOISTURE RESISTANCE) |
- |
3000 |
|
- |
| 16(LEAKAGE CURRENT AND ELECTRIC STRENGTH) |
- |
2000 |
|
- |
| 17(OVERLOAD PROTECTION OF TRANSFORMERS AND ASSOCIATED CIRCUITS) |
- |
2000 |
|
- |
| 18(ENDURANCE) |
- |
0 |
|
- |
| 28(SCREWS AND CONNECTIONS) |
- |
2000 |
|
- |
| 31(RESISTANCE TO RUSTING) |
- |
2000 |
|
- |
| 22(CONSTRUCTION) |
- |
2000 |
|
- |
| 24(COMPONENTS) |
- |
2000 |
|
- |
| 11(Heating) |
- |
2000 |
|
- |
|
19 Jul, 2027 |
- Included w.e.f 10.07.2025
Exclusion : Cl 19.11.4.1-19.11.4.7(EMI/EMC), Cl 32 Radiation, toxicity and similar hazards |
| 5395 |
SHRI KRISHNA TEST HOUSE PVT LTD (142)
| 8185606
| IS 18573 (2024) |
Cold formed welded carbon steel square and rectangular hollow sections for mechanical, general engineering and decorative purposes � Specification |
all |
15000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Clause. 3.0(Types) |
- |
15000 |
|
- |
| Clause.4.0(Carbon) |
- |
15000 |
|
- |
| Clause.4.0(Sulphur) |
- |
15000 |
|
- |
| Clause.4.0(Sulphur) |
- |
15000 |
|
- |
| Clause.4.0(Phosphorus) |
- |
15000 |
|
- |
| Clause.4.0(Silicon) |
- |
15000 |
|
- |
| Clause.4.0(Manganese) |
- |
15000 |
|
- |
| Clause.5.0(Supply of Material) |
- |
15000 |
|
- |
| Clause.5.0(Supply of Material) |
- |
15000 |
|
- |
| Clause.6.0(Workmanship) |
- |
15000 |
|
- |
| Clause.7.0(Straightness) |
- |
15000 |
|
- |
| Clause.8.0(Basis of Calculation) |
- |
15000 |
|
- |
| Clause.9.0(Length) |
- |
15000 |
|
- |
| Clause.10.0(Dimensions and properties) |
- |
15000 |
|
- |
| Clause.10.0(Dimensions and properties) |
- |
15000 |
|
- |
| Clause.11.0(General) |
- |
15000 |
|
- |
| Clause.11.0(Outside Dimension) |
- |
15000 |
|
- |
| Clause.11.0(Thickness) |
- |
15000 |
|
- |
| Clause.11.0(Thickness) |
- |
15000 |
|
- |
| Clause.11.0(Concavity and Convexity) |
- |
15000 |
|
- |
| Clause.11.0(Squareness of Sides) |
- |
15000 |
|
- |
| Clause.11.0(External Corner Radiius) |
- |
15000 |
|
- |
| Clause.11.0(Straightness and twist) |
- |
15000 |
|
- |
| Clause.12.0(Dimension Tolerances) |
- |
15000 |
|
- |
| Clause.12.0(Dimension Tolerances) |
- |
15000 |
|
- |
| Clause.13.0(Surface Protection) |
- |
15000 |
|
- |
| Clause.14.0(Testing) |
- |
15000 |
|
- |
| Clause.15.0(Tensile test) |
- |
15000 |
|
- |
| Clause.15.0(Yield strength) |
- |
15000 |
|
- |
| Clause.15.0(Elognation Percent) |
- |
15000 |
|
- |
| Clause.18.0(Marking) |
- |
15000 |
|
- |
| 6(Workmanship) |
- |
15000 |
|
- |
| 10(Dimensions and Properties) |
- |
15000 |
|
- |
| 11(Measurement of Shape and Size) |
- |
15000 |
|
- |
| 12(Dimensions and Tolerances) |
- |
15000 |
|
- |
| 13(Surface Protection) |
- |
15000 |
|
- |
| 15(Tensile Test) |
- |
15000 |
|
- |
|
13 May, 2028 |
- Included w.e.f 03.07.2025 |
| 5396 |
DELHI TEST HOUSE, Azadhpur
| 8131406
| IS 15905 (2024) |
Hubless Centrifugally Cast (Spun) Iron Pipes, Fittings and Accessories — Spigot Series —Specification |
ALL |
22000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl-5(Manufacture) |
- |
1000 |
|
Rs.500/- EXTRA EACH CHEMICAL PARAMETER,FOR UPTO 100MM SIZE WITH TWO OPENING MOUTH TESTING CHRGERS-Rs 2500/- AND EXTRA Rs 500/- EACH OPENING MOUTH&FOR ABOVE 100MM SIZE WITH TWO OPENING MOUTH TESTING CHRGERS-Rs 5000/- AND EXTRA Rs 1000/- EACH OPENING MOUTH, |
| Cl-5.4(pipes and fittings) |
- |
500 |
|
Rs.500/- EACH CHEMICAL PARAMETER,FOR UPTO 100MM SIZE WITH TWO OPENING MOUTH TESTING CHRGERS-Rs 2500/- AND EXTRA Rs 500/- EACH OPENING MOUTH&FOR > 100MM SIZE WITH TWO OPENING MOUTH TESTING CHRGERS-Rs 5000/- AND EXTRA Rs 1000/- EACH OPENING MOUTH, |
| Cl-6.2(EPDM) |
- |
10000 |
|
Rs.500/- EXTRA EACH CHEMICAL PARAMETER,FOR UPTO 100MM SIZE WITH TWO OPENING MOUTH TESTING CHRGERS-Rs 2500/- AND EXTRA Rs 500/- EACH OPENING MOUTH&FOR ABOVE 100MM SIZE WITH TWO OPENING MOUTH TESTING CHRGERS-Rs 5000/- AND EXTRA Rs 1000/- EACH OPENING MOUTH, |
| Cl-6.4(Minimum Free Lengths) |
- |
500 |
|
Rs.500/- EXTRA EACH CHEMICAL PARAMETER,FOR UPTO 100MM SIZE WITH TWO OPENING MOUTH TESTING CHRGERS-Rs 2500/- AND EXTRA Rs 500/- EACH OPENING MOUTH&FOR ABOVE 100MM SIZE WITH TWO OPENING MOUTH TESTING CHRGERS-Rs 5000/- AND EXTRA Rs 1000/- EACH OPENING MOUTH |
| Cl-8(Crush tests on pipes ring) |
- |
2000 |
|
Rs.500/- EXTRA EACH CHEMICAL PARAMETER,FOR UPTO 100MM SIZE WITH TWO OPENING MOUTH TESTING CHRGERS-Rs 2500/- AND EXTRA Rs 500/- EACH OPENING MOUTH&FOR ABOVE 100MM SIZE WITH TWO OPENING MOUTH TESTING CHRGERS-Rs 5000/- AND EXTRA Rs 1000/- EACH OPENING MOUTH, |
| Cl-9(Hydrostatic test) |
- |
5000 |
|
Rs.500/- EXTRA EACH CHEMICAL PARAMETER,FOR UPTO 100MM SIZE WITH TWO OPENING MOUTH TESTING CHRGERS-Rs 2500/- AND EXTRA Rs 500/- EACH OPENING MOUTH&FOR ABOVE 100MM SIZE WITH TWO OPENING MOUTH TESTING CHRGERS-Rs 5000/- AND EXTRA Rs 1000/- EACH OPENING MOUTH, |
| Cl-10.2(External Diameters and Tolerances) |
- |
250 |
|
Rs.500/- EXTRA EACH CHEMICAL PARAMETER,FOR UPTO 100MM SIZE WITH TWO OPENING MOUTH TESTING CHRGERS-Rs 2500/- AND EXTRA Rs 500/- EACH OPENING MOUTH&FOR ABOVE 100MM SIZE WITH TWO OPENING MOUTH TESTING CHRGERS-Rs 5000/- AND EXTRA Rs 1000/- EACH OPENING MOUTH, |
| Cl-10.3(Thickness and Tolerances) |
- |
250 |
|
Rs.500/- EXTRA EACH CHEMICAL PARAMETER,FOR UPTO 100MM SIZE WITH TWO OPENING MOUTH TESTING CHRGERS-Rs 2500/- AND EXTRA Rs 500/- EACH OPENING MOUTH&FOR ABOVE 100MM SIZE WITH TWO OPENING MOUTH TESTING CHRGERS-Rs 5000/- AND EXTRA Rs 1000/- EACH OPENING MOUTH, |
| Cl-10.4(Length and Tolerances) |
- |
250 |
|
Rs.500/- EXTRA EACH CHEMICAL PARAMETER,FOR UPTO 100MM SIZE WITH TWO OPENING MOUTH TESTING CHRGERS-Rs 2500/- AND EXTRA Rs 500/- EACH OPENING MOUTH&FOR ABOVE 100MM SIZE WITH TWO OPENING MOUTH TESTING CHRGERS-Rs 5000/- AND EXTRA Rs 1000/- EACH OPENING MOUTH, |
| Cl-10.5(Tolerances on Angles) |
- |
250 |
|
Rs.500/- EXTRA EACH CHEMICAL PARAMETER,FOR UPTO 100MM SIZE WITH TWO OPENING MOUTH TESTING CHRGERS-Rs 2500/- AND EXTRA Rs 500/- EACH OPENING MOUTH&FOR ABOVE 100MM SIZE WITH TWO OPENING MOUTH TESTING CHRGERS-Rs 5000/- AND EXTRA Rs 1000/- EACH OPENING MOUTH, |
| Cl-10.6(Straightness of Pipe) |
- |
250 |
|
Rs.500/- EXTRA EACH CHEMICAL PARAMETER,FOR UPTO 100MM SIZE WITH TWO OPENING MOUTH TESTING CHRGERS-Rs 2500/- AND EXTRA Rs 500/- EACH OPENING MOUTH&FOR ABOVE 100MM SIZE WITH TWO OPENING MOUTH TESTING CHRGERS-Rs 5000/- AND EXTRA Rs 1000/- EACH OPENING MOUTH, |
| Cl-10.7(End Faces) |
- |
250 |
|
Rs.500/- EXTRA EACH CHEMICAL PARAMETER,FOR UPTO 100MM SIZE WITH TWO OPENING MOUTH TESTING CHRGERS-Rs 2500/- AND EXTRA Rs 500/- EACH OPENING MOUTH&FOR ABOVE 100MM SIZE WITH TWO OPENING MOUTH TESTING CHRGERS-Rs 5000/- AND EXTRA Rs 1000/- EACH OPENING MOUTH, |
| Cl-10.8.1(Pipe) |
- |
1500 |
|
Rs.500/- EXTRA EACH CHEMICAL PARAMETER,FOR UPTO 100MM SIZE WITH TWO OPENING MOUTH TESTING CHRGERS-Rs 2500/- AND EXTRA Rs 500/- EACH OPENING MOUTH&FOR ABOVE 100MM SIZE WITH TWO OPENING MOUTH TESTING CHRGERS-Rs 5000/- AND EXTRA Rs 1000/- EACH OPENING MOUTH, |
| Cl-10.8.2.1(Bend) |
- |
1500 |
|
Rs.500/- EXTRA EACH CHEMICAL PARAMETER,FOR UPTO 100MM SIZE WITH TWO OPENING MOUTH TESTING CHRGERS-Rs 2500/- AND EXTRA Rs 500/- EACH OPENING MOUTH&FOR ABOVE 100MM SIZE WITH TWO OPENING MOUTH TESTING CHRGERS-Rs 5000/- AND EXTRA Rs 1000/- EACH OPENING MOUTH, |
| Cl-10.8.2.2(Bend with or without access door) |
- |
1500 |
|
Rs.500/- EXTRA EACH CHEMICAL PARAMETER,FOR UPTO 100MM SIZE WITH TWO OPENING MOUTH TESTING CHRGERS-Rs 2500/- AND EXTRA Rs 500/- EACH OPENING MOUTH&FOR ABOVE 100MM SIZE WITH TWO OPENING MOUTH TESTING CHRGERS-Rs 5000/- AND EXTRA Rs 1000/- EACH OPENING MOUTH, |
| Cl-10.8.2.3(Long radius bend) |
- |
1500 |
|
Rs.500/- EXTRA EACH CHEMICAL PARAMETER,FOR UPTO 100MM SIZE WITH TWO OPENING MOUTH TESTING CHRGERS-Rs 2500/- AND EXTRA Rs 500/- EACH OPENING MOUTH&FOR ABOVE 100MM SIZE WITH TWO OPENING MOUTH TESTING CHRGERS-Rs 5000/- AND EXTRA Rs 1000/- EACH OPENING MOUTH, |
| Cl-10.8.2.4(Long tail bend) |
- |
1500 |
|
Rs.500/- EXTRA EACH CHEMICAL PARAMETER,FOR UPTO 100MM SIZE WITH TWO OPENING MOUTH TESTING CHRGERS-Rs 2500/- AND EXTRA Rs 500/- EACH OPENING MOUTH&FOR ABOVE 100MM SIZE WITH TWO OPENING MOUTH TESTING CHRGERS-Rs 5000/- AND EXTRA Rs 1000/- EACH OPENING MOUTH, |
| Cl-10.8.2.5(Horn plain bend) |
- |
1500 |
|
Rs.500/- EXTRA EACH CHEMICAL PARAMETER,FOR UPTO 100MM SIZE WITH TWO OPENING MOUTH TESTING CHRGERS-Rs 2500/- AND EXTRA Rs 500/- EACH OPENING MOUTH&FOR ABOVE 100MM SIZE WITH TWO OPENING MOUTH TESTING CHRGERS-Rs 5000/- AND EXTRA Rs 1000/- EACH OPENING MOUTH, |
| Cl-10.8.2.6(Double bend) |
- |
1500 |
|
Rs.500/- EXTRA EACH CHEMICAL PARAMETER,FOR UPTO 100MM SIZE WITH TWO OPENING MOUTH TESTING CHRGERS-Rs 2500/- AND EXTRA Rs 500/- EACH OPENING MOUTH&FOR ABOVE 100MM SIZE WITH TWO OPENING MOUTH TESTING CHRGERS-Rs 5000/- AND EXTRA Rs 1000/- EACH OPENING MOUTH, |
| Cl-10.8.2.7(Single branch) |
- |
1500 |
|
Rs.500/- EXTRA EACH CHEMICAL PARAMETER,FOR UPTO 100MM SIZE WITH TWO OPENING MOUTH TESTING CHRGERS-Rs 2500/- AND EXTRA Rs 500/- EACH OPENING MOUTH&FOR ABOVE 100MM SIZE WITH TWO OPENING MOUTH TESTING CHRGERS-Rs 5000/- AND EXTRA Rs 1000/- EACH OPENING MOUTH, |
| Cl-10.8.2.8(Single branch with or without access door) |
- |
1500 |
|
Rs.500/- EXTRA EACH CHEMICAL PARAMETER,FOR UPTO 100MM SIZE WITH TWO OPENING MOUTH TESTING CHRGERS-Rs 2500/- AND EXTRA Rs 500/- EACH OPENING MOUTH&FOR ABOVE 100MM SIZE WITH TWO OPENING MOUTH TESTING CHRGERS-Rs 5000/- AND EXTRA Rs 1000/- EACH OPENING MOUTH, |
| Cl-10.8.2.9(Double branch) |
- |
1500 |
|
Rs.500/- EXTRA EACH CHEMICAL PARAMETER,FOR UPTO 100MM SIZE WITH TWO OPENING MOUTH TESTING CHRGERS-Rs 2500/- AND EXTRA Rs 500/- EACH OPENING MOUTH&FOR ABOVE 100MM SIZE WITH TWO OPENING MOUTH TESTING CHRGERS-Rs 5000/- AND EXTRA Rs 1000/- EACH OPENING MOUTH, |
| Cl-10.8.2.11(Diminishing pieces) |
- |
1500 |
|
Rs.500/- EXTRA EACH CHEMICAL PARAMETER,FOR UPTO 100MM SIZE WITH TWO OPENING MOUTH TESTING CHRGERS-Rs 2500/- AND EXTRA Rs 500/- EACH OPENING MOUTH&FOR ABOVE 100MM SIZE WITH TWO OPENING MOUTH TESTING CHRGERS-Rs 5000/- AND EXTRA Rs 1000/- EACH OPENING MOUTH, |
| Cl-10.8.2.12(Offset) |
- |
1500 |
|
Rs.500/- EXTRA EACH CHEMICAL PARAMETER,FOR UPTO 100MM SIZE WITH TWO OPENING MOUTH TESTING CHRGERS-Rs 2500/- AND EXTRA Rs 500/- EACH OPENING MOUTH&FOR ABOVE 100MM SIZE WITH TWO OPENING MOUTH TESTING CHRGERS-Rs 5000/- AND EXTRA Rs 1000/- EACH OPENING MOUTH, |
| Cl-10.8.2.13(Equal and unequal parallel branch) |
- |
1500 |
|
Rs.500/- EXTRA EACH CHEMICAL PARAMETER,FOR UPTO 100MM SIZE WITH TWO OPENING MOUTH TESTING CHRGERS-Rs 2500/- AND EXTRA Rs 500/- EACH OPENING MOUTH&FOR ABOVE 100MM SIZE WITH TWO OPENING MOUTH TESTING CHRGERS-Rs 5000/- AND EXTRA Rs 1000/- EACH OPENING MOUTH, |
| Cl-10.8.2.14(P trap) |
- |
1500 |
|
Rs.500/- EXTRA EACH CHEMICAL PARAMETER,FOR UPTO 100MM SIZE WITH TWO OPENING MOUTH TESTING CHRGERS-Rs 2500/- AND EXTRA Rs 500/- EACH OPENING MOUTH&FOR ABOVE 100MM SIZE WITH TWO OPENING MOUTH TESTING CHRGERS-Rs 5000/- AND EXTRA Rs 1000/- EACH OPENING MOUTH, |
| Cl-10.8.2.15(H ventilation pipe) |
- |
1500 |
|
Rs.500/- EXTRA EACH CHEMICAL PARAMETER,FOR UPTO 100MM SIZE WITH TWO OPENING MOUTH TESTING CHRGERS-Rs 2500/- AND EXTRA Rs 500/- EACH OPENING MOUTH&FOR ABOVE 100MM SIZE WITH TWO OPENING MOUTH TESTING CHRGERS-Rs 5000/- AND EXTRA Rs 1000/- EACH OPENING MOUTH, |
| Cl-10.8.2.16(Y ventilation pipe) |
- |
1500 |
|
Rs.500/- EXTRA EACH CHEMICAL PARAMETER,FOR UPTO 100MM SIZE WITH TWO OPENING MOUTH TESTING CHRGERS-Rs 2500/- AND EXTRA Rs 500/- EACH OPENING MOUTH&FOR ABOVE 100MM SIZE WITH TWO OPENING MOUTH TESTING CHRGERS-Rs 5000/- AND EXTRA Rs 1000/- EACH OPENING MOUTH, |
| Cl-10.8.2.17(T Y single branch) |
- |
1500 |
|
Rs.500/- EXTRA EACH CHEMICAL PARAMETER,FOR UPTO 100MM SIZE WITH TWO OPENING MOUTH TESTING CHRGERS-Rs 2500/- AND EXTRA Rs 500/- EACH OPENING MOUTH&FOR >100MM SIZE WITH TWO OPENING MOUTH TESTING CHRGERS-Rs 5000/- AND EXTRA Rs 1000/- EACH OPENING MOUTH, |
| Cl-10.8.2.18(Vent cowel) |
- |
1500 |
|
Rs.500/- EXTRA EACH CHEMICAL PARAMETER,FOR UPTO 100MM SIZE WITH TWO OPENING MOUTH TESTING CHRGERS-Rs 2500/- AND EXTRA Rs 500/- EACH OPENING MOUTH&FOR ABOVE 100MM SIZE WITH TWO OPENING MOUTH TESTING CHRGERS-Rs 5000/- AND EXTRA Rs 1000/- EACH OPENING MOUTH, |
| Cl-10.8.2.19(Inspection pipe (clean-out pipe)) |
- |
1500 |
|
Rs.500/- EXTRA EACH CHEMICAL PARAMETER,FOR UPTO 100MM SIZE WITH TWO OPENING MOUTH TESTING CHRGERS-Rs 2500/- AND EXTRA Rs 500/- EACH OPENING MOUTH&FOR ABOVE 100MM SIZE WITH TWO OPENING MOUTH TESTING CHRGERS-Rs 5000/- AND EXTRA Rs 1000/- EACH OPENING MOUTH, |
| Cl-10.8.2.20(Unequal trap) |
- |
1500 |
|
Rs.500/- EXTRA EACH CHEMICAL PARAMETER,FOR UPTO 100MM SIZE WITH TWO OPENING MOUTH TESTING CHRGERS-Rs 2500/- AND EXTRA Rs 500/- EACH OPENING MOUTH&FOR ABOVE 100MM SIZE WITH TWO OPENING MOUTH TESTING CHRGERS-Rs 5000/- AND EXTRA Rs 1000/- EACH OPENING MOUTH, |
| Cl-10.8.2.21(Single branch with or without door) |
- |
1500 |
|
Rs.500/- EXTRA EACH CHEMICAL PARAMETER,FOR UPTO 100MM SIZE WITH TWO OPENING MOUTH TESTING CHRGERS-Rs 2500/- AND EXTRA Rs 500/- EACH OPENING MOUTH&FOR ABOVE 100MM SIZE WITH TWO OPENING MOUTH TESTING CHRGERS-Rs 5000/- AND EXTRA Rs 1000/- EACH OPENING MOUTH, |
| Cl-10.8.2.22(Single branch socketed with access door) |
- |
1500 |
|
Rs.500/- EXTRA EACH CHEMICAL PARAMETER,FOR UPTO 100MM SIZE WITH TWO OPENING MOUTH TESTING CHRGERS-Rs 2500/- AND EXTRA Rs 500/- EACH OPENING MOUTH&FOR ABOVE 100MM SIZE WITH TWO OPENING MOUTH TESTING CHRGERS-Rs 5000/- AND EXTRA Rs 1000/- EACH OPENING MOUTH, |
| Cl-10.8.2.23(Multi inlet pipe) |
- |
1500 |
|
Rs.500/- EXTRA EACH CHEMICAL PARAMETER,FOR UPTO 100MM SIZE WITH TWO OPENING MOUTH TESTING CHRGERS-Rs 2500/- AND EXTRA Rs 500/- EACH OPENING MOUTH&FOR ABOVE 100MM SIZE WITH TWO OPENING MOUTH TESTING CHRGERS-Rs 5000/- AND EXTRA Rs 1000/- EACH OPENING MOUTH, |
| Cl-10.8.2.24(Floor trap (deep seal)) |
- |
1500 |
|
Rs.500/- EXTRA EACH CHEMICAL PARAMETER,FOR UPTO 100MM SIZE WITH TWO OPENING MOUTH TESTING CHRGERS-Rs 2500/- AND EXTRA Rs 500/- EACH OPENING MOUTH&FOR ABOVE 100MM SIZE WITH TWO OPENING MOUTH TESTING CHRGERS-Rs 5000/- AND EXTRA Rs 1000/- EACH OPENING MOUTH, |
| Cl-10.8.2.25(Access door) |
- |
1500 |
|
Rs.500/- EXTRA EACH CHEMICAL PARAMETER,FOR UPTO 100MM SIZE WITH TWO OPENING MOUTH TESTING CHRGERS-Rs 2500/- AND EXTRA Rs 500/- EACH OPENING MOUTH&FOR ABOVE 100MM SIZE WITH TWO OPENING MOUTH TESTING CHRGERS-Rs 5000/- AND EXTRA Rs 1000/- EACH OPENING MOUTH, |
| Cl-11.2(Resistance to Salt Spray) |
- |
5000 |
|
RS.15/- EACH Hrs. |
| Cl-12(Marking) |
- |
250 |
|
Rs.500/- EXTRA EACH CHEMICAL PARAMETER,FOR UPTO 100MM SIZE WITH TWO OPENING MOUTH TESTING CHRGERS-Rs 2500/- AND EXTRA Rs 500/- EACH OPENING MOUTH&FOR ABOVE 100MM SIZE WITH TWO OPENING MOUTH TESTING CHRGERS-Rs 5000/- AND EXTRA Rs 1000/- EACH OPENING MOUTH, |
| Cl-6(Joints) |
- |
5000 |
|
IF REQUIRED CLAMPING COMPONENT TESTING |
|
17 Jun, 2027 |
- Included w.e.f 28.07.2025 |
| 5397 |
Atharva Laboratories Pvt. Ltd. (C-54), Noida
| 8165026
| IS 12254 (2021) |
POLYVINYLCHLORIDE PVC INDUSTRIAL BOOTS - SPECIFICATION Second Revision |
- |
44500 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 5.2(Size) |
- |
100 |
|
- |
| 5.3(Height) |
- |
200 |
|
- |
| 5.4.2(Ergonomic feature) |
- |
500 |
|
- |
| 5.4.3(Sole bond) |
- |
800 |
|
- |
| 5.4.4(Slip resistance) |
- |
1500 |
|
- |
| 5.4.5(Leak proofness) |
- |
800 |
|
- |
| 5.4.6.1(Toe caps General) |
- |
200 |
|
- |
| 5.4.6.2(Internal length of toecaps) |
- |
200 |
|
- |
| 5.4.6.3(Corrosion resistance) |
- |
1000 |
|
- |
| 5.4.6.4(Impact resistance) |
- |
1000 |
|
- |
| 5.4.6.5(Compression resistance) |
- |
1000 |
|
- |
| 5.4.7(Colour) |
- |
150 |
|
- |
| 5.5.1(Upper material) |
- |
200 |
|
- |
| 5.5.1(Upper Thickness) |
- |
200 |
|
- |
| 5.5.2(Upper tensile strength) |
- |
800 |
|
- |
| 5.5.3(Upper flexing) |
- |
1200 |
|
- |
| 5.5.4(Upper Hardness) |
- |
500 |
|
- |
| 5.6.1(Lining material) |
- |
200 |
|
- |
| 5.6.2(Lining Tear strength) |
- |
800 |
|
- |
| 5.6.3(Lining abrasion) |
- |
1200 |
|
- |
| 5.6.4(Lining adhesion with upper) |
- |
800 |
|
- |
| 5.7.1(Insole material) |
- |
200 |
|
- |
| 5.7.1(Insole thickness) |
- |
200 |
|
- |
| 5.7.2(Insole abrasion) |
- |
600 |
|
- |
| 5.7.3(Water absorption and desorption) |
- |
1000 |
|
- |
| 5.8.2(Eyelets material) |
- |
200 |
|
- |
| 5.8.2(Lace material) |
- |
200 |
|
- |
| 5.8.2(Lace length) |
- |
200 |
|
- |
| 5.8.2(Lace breaking load) |
- |
800 |
|
- |
| 5.9.1(Insock material) |
- |
200 |
|
- |
| 5.9.2(Inscok abrasion resistance) |
- |
1200 |
|
- |
| 5.9.3(Insock water absorption and desorption) |
- |
1000 |
|
- |
| 5.8.2(Closing thread breaking load) |
- |
800 |
|
- |
| 5.11.1(Outsole material) |
- |
200 |
|
- |
| 5.11.1(Outsole thickness) |
- |
200 |
|
- |
| 5.11.2(Outsole density) |
- |
800 |
|
- |
| 5.11.3(Outsole Interlayer bond) |
- |
800 |
|
- |
| 5.11.4(Outsole tear) |
- |
800 |
|
- |
| 5.11.5(Outsole Abrasion) |
- |
1200 |
|
- |
| 5.11.6(Outsole hardness) |
- |
500 |
|
- |
| 5.11.7(Outsole flexing) |
- |
1200 |
|
- |
| 5.4.8.1(Conductive Footwear) |
- |
1500 |
|
- |
| 5.4.8.2(Antistatic Footwear) |
- |
1500 |
|
- |
| 5.4.8.3.2(Penetration resistance) |
- |
800 |
|
- |
| 5.4.8.4(Cut resistance) |
- |
800 |
|
- |
| 5.5.5(Upper Cold flex resistance) |
- |
0 |
|
- |
| 5.4.8.5(Outsole resistance to acid and alkali) |
- |
2000 |
|
- |
| 5.4.8.6(Outsole resistance to fuel oil) |
- |
1000 |
|
- |
| 5.11.8(Outsole cold flex resistance) |
- |
2000 |
|
- |
| 6.1(Volatility) |
- |
600 |
|
- |
| 6.2(Lead content) |
- |
600 |
|
- |
| Table 1 as per IS 17011 2018(pH) |
- |
600 |
|
Chemical package charges 30000/- |
| Table 1 as per IS 17011 2018(Phthalates (each individual phthalate)) |
- |
3000 |
|
- |
| Table 1 as per IS 17011 2018(Nickel, on skin contact) |
- |
3000 |
|
- |
| Table 1 as per IS 17011 2018(Allergenic and carcinogenic disperse dyes) |
- |
3000 |
|
- |
| Table 1 as per IS 17011 2018(Aromatic amines released from Azo dyes (each individual amine)) |
- |
3000 |
|
- |
| Table 1 as per IS 17011 2018(Aromatic amines released from Azo dyes (each individual amine)) |
- |
3000 |
|
- |
| Table 1 as per IS 17011 2018(Chromium (VI)) |
- |
3000 |
|
- |
| Table 1 as per IS 17011 2018(Dimethyl fumarate (DMFU)) |
- |
3000 |
|
- |
| Table 1 as per IS 17011 2018(Formaldehyde (free or released by partial hydrolysis)) |
- |
3000 |
|
- |
| Table 1 as per IS 17011 2018(Formaldehyde) |
- |
3000 |
|
- |
| Table 1 as per IS 17011 2018(Organotin compounds) |
- |
3000 |
|
- |
| Table 1 as per IS 17011 2018(PCP-TeCP-TriCP polychlorophenols) |
- |
3000 |
|
- |
| 5.10(Closing Thread (If used)) |
- |
800 |
|
- |
| Cl.6.1(Volatility- IS 12240 (Part 4)) |
- |
800 |
|
- |
| Cl.6.2(Lead Content-IS 12240 (Part 5),) |
- |
800 |
|
- |
| 5.2(Size) |
- |
0 |
|
- |
| 5.3(Height) |
- |
0 |
|
- |
| 5.4.2(Ergonomic feature) |
- |
0 |
|
- |
| 5.4.3(Sole bond) |
- |
0 |
|
- |
| 5.4.4(Slip resistance) |
- |
0 |
|
- |
| 5.4.5(Leak proofness) |
- |
0 |
|
- |
| 5.4.6.1(Toe caps General) |
- |
0 |
|
- |
| 5.4.6.2(Internal length of toecaps) |
- |
0 |
|
- |
| 5.4.6.3(Corrosion resistance) |
- |
0 |
|
- |
| 5.4.6.4(Impact resistance) |
- |
0 |
|
- |
| 5.4.6.5(Compression resistance) |
- |
0 |
|
- |
| 5.4.7(Colour) |
- |
0 |
|
- |
| 5.5.1(Upper material) |
- |
0 |
|
- |
| 5.5.1(Upper Thickness) |
- |
0 |
|
- |
| 5.5.2(Upper tensile strength) |
- |
0 |
|
- |
| 5.5.3(Upper flexing) |
- |
0 |
|
- |
| 5.5.4(Upper Hardness) |
- |
0 |
|
- |
| 5.6.1(Lining material) |
- |
0 |
|
- |
| 5.6.2(Lining Tear strength) |
- |
0 |
|
- |
| 5.6.3(Lining abrasion) |
- |
0 |
|
- |
| 5.6.4(Lining adhesion with upper) |
- |
0 |
|
- |
| 5.7.1(Insole material) |
- |
0 |
|
- |
| 5.7.1(Insole thickness) |
- |
0 |
|
- |
| 5.7.2(Insole abrasion) |
- |
0 |
|
- |
| 5.7.3(Water absorption and desorption) |
- |
0 |
|
- |
| 5.8.2(Eyelets material) |
- |
0 |
|
- |
| 5.8.2(Lace material) |
- |
0 |
|
- |
| 5.8.2(Lace length) |
- |
0 |
|
- |
| 5.8.2(Lace breaking load) |
- |
0 |
|
- |
| 5.9.1(Insock material) |
- |
0 |
|
- |
| 5.9.2(Inscok abrasion resistance) |
- |
0 |
|
- |
| 5.9.3(Insock water absorption and desorption) |
- |
0 |
|
- |
| 5.8.2(Closing thread breaking load) |
- |
0 |
|
- |
| 5.11.1(Outsole material) |
- |
0 |
|
- |
| 5.11.1(Outsole thickness) |
- |
0 |
|
- |
| 5.11.2(Outsole density) |
- |
0 |
|
- |
| 5.11.3(Outsole Interlayer bond) |
- |
0 |
|
- |
| 5.11.4(Outsole tear) |
- |
0 |
|
- |
| 5.11.5(Outsole Abrasion) |
- |
0 |
|
- |
| 5.11.6(Outsole hardness) |
- |
0 |
|
- |
| 5.11.7(Outsole flexing) |
- |
0 |
|
- |
| 5.4.8.1(Conductive Footwear) |
- |
0 |
|
- |
| 5.4.8.2(Antistatic Footwear) |
- |
0 |
|
- |
| 5.4.8.3.2(Penetration resistance) |
- |
0 |
|
- |
| 5.4.8.4(Cut resistance) |
- |
0 |
|
- |
| 5.5.5(Upper Cold flex resistance) |
- |
0 |
|
- |
| 5.4.8.5(Outsole resistance to acid and alkali) |
- |
0 |
|
- |
| 5.4.8.6(Outsole resistance to fuel oil) |
- |
0 |
|
- |
| 5.11.8(Outsole cold flex resistance) |
- |
0 |
|
- |
| 6.1(Volatility) |
- |
0 |
|
- |
| 6.2(Lead content) |
- |
0 |
|
- |
| Table 1 as per IS 17011 2018(pH) |
- |
0 |
|
- |
| Table 1 as per IS 17011 2018(Phthalates (each individual phthalate)) |
- |
0 |
|
- |
| Table 1 as per IS 17011 2018(Nickel, on skin contact) |
- |
0 |
|
- |
| Table 1 as per IS 17011 2018(Allergenic and carcinogenic disperse dyes) |
- |
0 |
|
- |
| Table 1 as per IS 17011 2018(Aromatic amines released from Azo dyes (each individual amine)) |
- |
0 |
|
- |
| Table 1 as per IS 17011 2018(Aromatic amines released from Azo dyes (each individual amine)) |
- |
0 |
|
- |
| Table 1 as per IS 17011 2018(Chromium (VI)) |
- |
0 |
|
- |
| Table 1 as per IS 17011 2018(Dimethyl fumarate (DMFU)) |
- |
0 |
|
- |
| Table 1 as per IS 17011 2018(Formaldehyde (free or released by partial hydrolysis)) |
- |
0 |
|
- |
| Table 1 as per IS 17011 2018(Formaldehyde) |
- |
0 |
|
- |
| Table 1 as per IS 17011 2018(Organotin compounds) |
- |
0 |
|
- |
| Table 1 as per IS 17011 2018(PCP-TeCP-TriCP polychlorophenols) |
- |
0 |
|
- |
| 5.10(Closing Thread (If used)) |
- |
0 |
|
- |
| Cl.6.1(Volatility- IS 12240 (Part 4)) |
- |
0 |
|
- |
| Cl.6.2(Lead Content-IS 12240 (Part 5),) |
- |
0 |
|
- |
|
- |
- Included w.e.f. 12.11.2025
5.5.5 (Upper Cold flex resistance) |
| 5398 |
Gravitas Laboratories Private Limited, Greater Noida
| 8182606
| IS 2385 (1977) |
Specification for hot - Rolled mild steel sheet and strip in coil form for cold - Reduced tinplate and cold - Reduced blackplate (First Revision) |
All Size |
10000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl. 5.1, 5.2 & Table1(Carbon- Appropriate parts of IS 228 or any other established Instrumental/Chemical method.) |
- |
7000 |
|
- |
| Cl. 5.1, 5.2 & Table1(Manganese- Appropriate parts of IS 228 or any other established Instrumental/Chemical method.) |
- |
7000 |
|
- |
| Cl. 5.1, 5.2 & Table1(Sulphur- Appropriate parts of IS 228 or any other established Instrumental/Chemical method.) |
- |
7000 |
|
- |
| Cl. 5.1, 5.2 & Table1(Phosphorus- Appropriate parts of IS 228 or any other established Instrumental/Chemical method.) |
- |
7000 |
|
- |
| Cl. 5.1, 5.2 & Table1(Nitrogen- Appropriate parts of IS 228 or any other established Instrumental/Chemical method.) |
- |
7000 |
|
- |
| Cl. 5.1, 5.2 & Table1(Aluminium- Appropriate parts of IS 228 or any other established Instrumental/Chemical method.) |
- |
7000 |
|
- |
| 6(Freedom from defects) |
- |
5000 |
|
- |
| 8(Dimensions and Tolerances) |
- |
5000 |
|
- |
| Cl. 5.1, 5.2(chromium) |
- |
7000 |
|
- |
| Cl. 5.1, 5.2(silicon) |
- |
7000 |
|
- |
| Cl. 5.1, 5.2(copper) |
- |
7000 |
|
- |
| Cl. 5.1, 5.2(aluminium) |
- |
7000 |
|
- |
| Cl. 5.1, 5.2(Nitrogen ) |
- |
7000 |
|
- |
| Cl. 5.1, 5.2(Phosphorus) |
- |
7000 |
|
- |
| Cl. 5.1, 5.2(Sulphur) |
- |
7000 |
|
- |
| Cl. 5.1, 5.2(Manganese) |
- |
7000 |
|
- |
| Cl. 5.1, 5.2(carbon) |
- |
7000 |
|
- |
| Cl. 5.1, 5.2 & Table1(Carbon- Appropriate parts of IS 228 or any other established Instrumental/Chemical method.) |
- |
0 |
|
- |
| Cl. 5.1, 5.2 & Table1(Manganese- Appropriate parts of IS 228 or any other established Instrumental/Chemical method.) |
- |
0 |
|
- |
| Cl. 5.1, 5.2 & Table1(Sulphur- Appropriate parts of IS 228 or any other established Instrumental/Chemical method.) |
- |
0 |
|
- |
| Cl. 5.1, 5.2 & Table1(Phosphorus- Appropriate parts of IS 228 or any other established Instrumental/Chemical method.) |
- |
0 |
|
- |
| Cl. 5.1, 5.2 & Table1(Nitrogen- Appropriate parts of IS 228 or any other established Instrumental/Chemical method.) |
- |
0 |
|
- |
| Cl. 5.1, 5.2 & Table1(Aluminium- Appropriate parts of IS 228 or any other established Instrumental/Chemical method.) |
- |
0 |
|
- |
| 6(Freedom from defects) |
- |
0 |
|
- |
| 8(Dimensions and Tolerances) |
- |
0 |
|
- |
| Cl. 5.1, 5.2(chromium) |
- |
0 |
|
- |
| Cl. 5.1, 5.2(silicon) |
- |
0 |
|
- |
| Cl. 5.1, 5.2(copper) |
- |
0 |
|
- |
| Cl. 5.1, 5.2(aluminium) |
- |
0 |
|
- |
| Cl. 5.1, 5.2(Nitrogen ) |
- |
0 |
|
- |
| Cl. 5.1, 5.2(Phosphorus) |
- |
0 |
|
- |
| Cl. 5.1, 5.2(Sulphur) |
- |
0 |
|
- |
| Cl. 5.1, 5.2(Manganese) |
- |
0 |
|
- |
| Cl. 5.1, 5.2(carbon) |
- |
0 |
|
- |
|
- |
- Included w.e.f 22.07.2025 |
| 5399 |
JBS TESTING SOLUTIONS PVT LTD (27), JALANDHAR
| 9164606
| IS 5517 (1993) |
Steels for hardening and tempering - Speicification (Second Revision) |
- |
42500 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl. 6.1, 6.2, 6.3, 11.2, 15.1 & Table 2(Carbon- IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
5000 |
|
For complete chemical testing |
| Cl. 6.1, 6.2, 6.3, 11.2, 15.1 & Table 2(Manganese- IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
5000 |
|
For complete chemical testing |
| Cl. 6.1, 6.2, 6.3, 11.2, 15.1 & Table 2(Silicon- IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
5000 |
|
For complete chemical testing |
| Cl. 6.1, 6.2, 6.3, 11.2, 15.1 & Table 2(Nickel- IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
5000 |
|
For complete chemical testing |
| Cl. 6.1, 6.2, 6.3, 11.2, 15.1 & Table 2(Chromium- IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
5000 |
|
For complete chemical testing |
| Cl. 6.1, 6.2, 6.3, 11.2, 15.1 & Table 2(Molybdenum- IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
5000 |
|
For complete chemical testing |
| Cl. 6.1, 6.2, 6.3, 11.2, 15.1 & Table 2(Vanadium- IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
5000 |
|
For complete chemical testing |
| Cl. 6.1, 6.2, 6.3, 11.2, 15.1 & Table 2(Aluminium IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
5000 |
|
For complete chemical testing |
| Cl. 6.1, 6.2, 6.3, 11.2, 15.1 & Table 2(Sulphur- IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
5000 |
|
For complete chemical testing |
| Cl. 6.1, 6.2, 6.3, 11.2, 15.1 & Table 2(Phosphorus- IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
5000 |
|
For complete chemical testing |
| Cl. 6.1, 6.2, 6.3, 11.2, 15.1 & Table 2(Copper- IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
5000 |
|
For complete chemical testing |
| Cl. 6.1, 6.2, 6.3, 11.2, 15.1 & Table 2(Boron- IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
5000 |
|
For complete chemical testing |
| Cl. 6.1, 6.2, 6.3, 11.2, 15.1 & Table 2(Tin- IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
5000 |
|
For complete chemical testing |
| 5(Freedom from defects , IS 5517) |
- |
2500 |
|
For dimension and other qualitative tests |
| 8,Table 6(Hardness Test - IS 1500(Pt -1)) |
- |
12500 |
|
Mechanical testing (tensile and Hardness) |
| 9, Table 5(Mechanical ptoperties - IS 1608(Pt -1),IS 1598) |
- |
12500 |
|
Mechanical testing (tensile and Hardness) |
| 10(Grain Size - IS 4748) |
- |
2500 |
|
For dimension and other qualitative tests |
| 11.1(Inclusion Rating- IS 4163) |
- |
2500 |
|
For dimension and other qualitative tests |
| 11.2(Blue Fracture Test - IS 10138 (Pt1)) |
- |
3500 |
|
For Blue fracture test |
| 11.2(Step Down Test- IS 10138(Pt2)) |
- |
2500 |
|
For dimension and other qualitative tests |
| 11.2(Magnetic Particle Test -- IS 10138(Pt3)) |
- |
2500 |
|
For dimension and other qualitative tests |
| 12;Table 7(Hardenability Test-IS 3848) |
- |
2500 |
|
For dimension and other qualitative tests |
| 13.1&13.2&13.3(Dimensional tolerances- IS 3739 and is 3469(Pt 1to 3); Tolerance on straightness) |
- |
2500 |
|
For dimension and other qualitative tests |
| 16.1 a)(Additional Test; Macro etch Test) |
- |
2500 |
|
- |
| 16.1 b)(Additional Test; Ultrasonic Test -IS 3664) |
- |
1000 |
|
For additional mechanical tests |
| 16.1 c); Table 7(Additional Test;Hardenability Test) |
- |
1000 |
|
For additional mechanical tests |
| 16.1 d);Table 5(Additional Test;Blank Hardening Test) |
- |
1000 |
|
For additional mechanical tests |
| 16.1 e)(Additional Test;Cleanliness Test-IS 10138(Pt 1to3)) |
- |
1000 |
|
For additional mechanical tests |
| 16.1 f)(Microstructure for machinability,including banding) |
- |
5000 |
|
For microstructure tests |
| 16.1 g)(Hot up set for forgability) |
- |
5000 |
|
For Forgability test |
| Cl 6.2 & Table 2(Carbon- IS 228(Part 1)) |
- |
5000 |
|
For complete chemical testing |
| Cl 6.2 & Table 3(Sulphur- IS 228(Part 9)) |
- |
5000 |
|
For complete chemical testing |
| Cl 6.2 & Table 4(Phosphorous- IS 228(Part 3)) |
- |
5000 |
|
For complete chemical testing |
| Cl 6.2 & Table 5(Manganese- IS 228(Part 2)) |
- |
5000 |
|
For complete chemical testing |
| Cl 6.2 & Table 6(Silicon- IS 228(Part 2)) |
- |
5000 |
|
For complete chemical testing |
|
- |
- Included w.e.f 26.06.2025 |
| 5400 |
Byte Scientific Research Lab Private Limited
| 8189436
| IS/ISO 834 : Part 8 (2002) |
Fire-Resistance Tests - Elements of Building Construction Part 8 Specific Requirements for Non-load Bearing Vertical Separating Elements |
upto size 3 meter x 3 meter |
440000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 10(Integrity, Insulation) |
- |
440000 |
|
Installation of sample would be done by client itself at our facility. |
|
28 Oct, 2028 |
- - |