| 7081 |
URS PRODUCTS AND TESTING PVT. LTD. (A29), NOIDA
| 8168906
| IS 13395 (2021) |
Performance of Handles and Handle Assemblies Attached to Cookware - Specification ( First Revision ) |
- |
10000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4.1(Construction) |
- |
200 |
|
- |
| 4.2(Materials) |
- |
200 |
|
- |
| 4.3(Selection and Size) |
- |
200 |
|
- |
| 4.4(Position of handle and knob with respect to cookware) |
- |
200 |
|
- |
| 4.5(Attachment to cookware) |
- |
200 |
|
- |
| 4.() |
- |
200 |
|
- |
| 4.() |
- |
200 |
|
- |
| 5.1(General) |
- |
400 |
|
- |
| 5.2(Bending strength) |
- |
800 |
|
- |
| 5.3(Torque strength) |
- |
800 |
|
- |
| 5.4(Impact strength) |
- |
800 |
|
- |
| 5.5(Fatigue resistance) |
- |
3000 |
|
- |
| 5.6(Leakage) |
- |
2000 |
|
- |
| 5.7(Thermal insulation) |
- |
1000 |
|
- |
| 5.8(Heat resistance) |
- |
800 |
|
- |
| 5.9(Washing resistance) |
- |
900 |
|
- |
| 5.10(Burning resistance) |
- |
900 |
|
- |
|
- |
- - |
| 7082 |
URS PRODUCTS AND TESTING PVT. LTD. (A29), NOIDA
| 8168906
| IS 6911 (2017) |
Stainless steel plate, sheet and strip - Specification (Second Revision) |
- |
8000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 6(Freedom from defects , IS 6911) |
- |
100 |
|
- |
| Cl. 7.1 & 7.2 Table 1(Carbon -IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
300 |
|
- |
| Cl. 7.1 & 7.2 Table 1(Chromium -IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
300 |
|
- |
| Cl. 7.1 & 7.2 Table 1(Copper -IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
300 |
|
- |
| Cl. 7.1 & 7.2 Table 1(Manganese -IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
300 |
|
- |
| Cl. 7.1 & 7.2 Table 1(Molybdenum -IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
300 |
|
- |
| Cl. 7.1 & 7.2 Table 1(Nickel -IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
300 |
|
- |
| Cl. 7.1 & 7.2 Table 1(Nitrogen -IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
300 |
|
- |
| Cl. 7.1 & 7.2 Table 1(Phosphorus -IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
300 |
|
- |
| Cl. 7.1 & 7.2 Table 1(Sulphur -IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
300 |
|
- |
| Cl. 7.1 & 7.2 Table 1(Silicon -IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
300 |
|
- |
| Cl. 7.1 & 7.2 Table 1(Niobium-IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
300 |
|
- |
| Cl. 7.1 & 7.2 Table 1(Titanium-IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
300 |
|
- |
| Cl. 7.1 & 7.2 Table 1(Others-IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
300 |
|
- |
| 10.1 - 4(Tensile Test) |
- |
800 |
|
- |
| 10.1 - 4(Yield strength) |
- |
800 |
|
- |
| 10.1 Amd 2(0.2 Percent Proof Stress) |
- |
1000 |
|
- |
| 10.1 - 4(Elongation % on 50mm) |
- |
700 |
|
- |
| 10.2(Hardness Test) |
- |
800 |
|
- |
| 10.3(Bend Test) |
- |
700 |
|
- |
| 11(Erichsen Cupping Test) |
- |
700 |
|
- |
| 17(Dimension and tolerance) |
- |
300 |
|
- |
| 12(Corrosion resistance) |
- |
500 |
|
- |
|
- |
- - |
| 7083 |
URS PRODUCTS AND TESTING PVT. LTD. (A29), NOIDA
| 8168906
| IS 6528 (1995) |
Stainless steel wire - Specification (First Revision) |
- |
7000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl 6(Workmanship) |
- |
100 |
|
- |
| Table-1,( Clauses 7.1, 7.2, 7.3 and 12.1)(Titanium) |
- |
300 |
|
- |
| Table-1,( Clauses 7.1, 7.2, 7.3 and 12.1)(Vanadium) |
- |
300 |
|
- |
| Table-1,( Clauses 7.1, 7.2, 7.3 and 12.1)(Boron) |
- |
300 |
|
- |
| Table-1,( Clauses 7.1, 7.2, 7.3 and 12.1)(Aluminium) |
- |
300 |
|
- |
| Table-1,( Clauses 7.1, 7.2, 7.3 and 12.1)(Carbon) |
- |
300 |
|
- |
| Table-1,( Clauses 7.1, 7.2, 7.3 and 12.1)(Chromium) |
- |
300 |
|
- |
| Table-1,( Clauses 7.1, 7.2, 7.3 and 12.1)(Copper) |
- |
300 |
|
- |
| Table-1,( Clauses 7.1, 7.2, 7.3 and 12.1)(Manganese) |
- |
300 |
|
- |
| Table-1,( Clauses 7.1, 7.2, 7.3 and 12.1)(Molybdenum) |
- |
300 |
|
- |
| Table-1,( Clauses 7.1, 7.2, 7.3 and 12.1)(Nickel) |
- |
300 |
|
- |
| Table-1,( Clauses 7.1, 7.2, 7.3 and 12.1)(Nitrogen) |
- |
300 |
|
- |
| Table-1,( Clauses 7.1, 7.2, 7.3 and 12.1)(Phosphorous) |
- |
300 |
|
- |
| Table-1,( Clauses 7.1, 7.2, 7.3 and 12.1)(Silicon) |
- |
300 |
|
- |
| Table-1,( Clauses 7.1, 7.2, 7.3 and 12.1)(Sulphor) |
- |
300 |
|
- |
| Cl 9.1 & Table 3(Diameter & Out Of Round) |
- |
300 |
|
- |
| Cl 10(UTM) |
- |
2000 |
|
- |
| 10.3(Torsion test- IS 1717) |
- |
1000 |
|
- |
| 10.4(Wrapping test-IS 1755) |
- |
1000 |
|
- |
| 15(Corrosion Resistance - IS:10461) |
- |
800 |
|
- |
|
- |
- - |
| 7084 |
URS PRODUCTS AND TESTING PVT. LTD. (A29), NOIDA
| 8168906
| IS 5522 (2014) |
Stainless steel sheets and strips for utensils - Specification (Third Revision) |
- |
6000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl . 6 .0(Freedom from defect) |
- |
100 |
|
- |
| Cl. 7.1 & 7.2 Table 1(Carbon -IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
200 |
|
- |
| Cl. 7.1 & 7.2 Table 1(Silicon -IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
200 |
|
- |
| Cl. 7.1 & 7.2 Table 1(Manganese -IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
2002 |
|
- |
| Cl. 7.1 & 7.2 Table 1(Nickel -IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
200 |
|
- |
| Cl. 7.1 & 7.2 Table 1(Chromium -IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
200 |
|
- |
| Cl. 7.1 & 7.2 Table 1(Sulphur -IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
200 |
|
- |
| Cl. 7.1 & 7.2 Table 1(Phosphorus -IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
200 |
|
- |
| Cl. 7.1 & 7.2 Table 1(Nitrogen -IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
200 |
|
- |
| 8.2, Table 3(Tensile Test-1608:Part 1) |
- |
2000 |
|
- |
| 8.2, Table 3(Proof Stress, N/mm2) |
- |
1500 |
|
- |
| 8.2, Table 3(Tensile Strength, N/mm2) |
- |
1000 |
|
- |
| 8.2, Table 3(Elongation, %) |
- |
800 |
|
- |
| 8.3(Hardness , max-IS 1500 or IS 1501 (Part 1) or IS 1586) |
- |
800 |
|
- |
| 8.4(Bend Test) |
- |
500 |
|
- |
| 8.5(Erichsen Cupping Test) |
- |
700 |
|
- |
| 10.1(Thickness, mm) |
- |
200 |
|
- |
| 10.2(width, mm) |
- |
200 |
|
- |
| 10.3(Length, mm) |
- |
200 |
|
- |
| 10.4(Flatness,mm) |
- |
200 |
|
- |
| 10.5(Camber, mm) |
- |
200 |
|
- |
| 11(Surface Finish) |
- |
100 |
|
- |
|
- |
- - |
| 7085 |
URS PRODUCTS AND TESTING PVT. LTD. (A29), NOIDA
| 8168906
| IS 740 (1977) |
Specification for wrought aluminium and aluminium alloy rivet stock for general engineering purposes (Second Revision) |
- |
13000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4.1,
Table 1of IS:740 (Designation 65032)(Aluminium) |
- |
600 |
|
- |
| 4.1,
Table 1of IS:740 (Designation 64430)(Aluminium) |
- |
600 |
|
- |
| 4.1,
Table 1of IS:740 (Designation 55000)(Aluminium) |
- |
600 |
|
- |
| 4.1,
Table 1of IS:740 (Designation 53000)(Aluminium) |
- |
600 |
|
- |
| 4.1,
Table 1of IS:740 (Designation 24345)(Aluminium) |
- |
600 |
|
- |
| 4.1,
Table 1of IS:740 (Designation 19000)(Aluminium) |
- |
600 |
|
- |
| 4.1,
Table 1of IS:740 (Designation 65032)(Either Cr or Mn shall present) |
- |
600 |
|
- |
| 4.1,
Table 1of IS:740 (Designation 65032)(Titanium and or other grain refining elements) |
- |
600 |
|
- |
| 4.1,
Table 1of IS:740 (Designation 64430)(Cr+Mn) |
- |
600 |
|
- |
| 4.1,
Table 1of IS:740 (Designation 64430)(Titanium and or other grain refining elements) |
- |
600 |
|
- |
| 4.1,
Table 1of IS:740 (Designation 55000)(Cr+Mn) |
- |
600 |
|
- |
| 4.1,
Table 1of IS:740 (Designation 55000)(Titanium and or other grain refining elements) |
- |
600 |
|
- |
| 4.1,
Table 1of IS:740 (Designation 53000)(Cr+Mn) |
- |
600 |
|
- |
| 4.1,
Table 1of IS:740 (Designation 53000)(Titanium and or other grain refining elements) |
- |
600 |
|
- |
| 4.1,
Table 1of IS:740 (Designation 24345)(Titanium and or other grain refining elements) |
- |
600 |
|
- |
| 4.1,
Table 1of IS:740 (Designation 19000)(Cu+Mg+Si+Fe+Mn+Zn) |
- |
600 |
|
- |
| 4.1,
Table 1of IS:740 (Designation 65032)(Chromium) |
- |
600 |
|
- |
| 4.1,
Table 1of IS:740 (Designation 65032)(Copper) |
- |
600 |
|
- |
| 4.1,
Table 1of IS:740 (Designation 65032)(Iron) |
- |
600 |
|
- |
| 4.1,
Table 1of IS:740 (Designation 65032)(Magnesium) |
- |
600 |
|
- |
| 4.1,
Table 1of IS:740 (Designation 65032)(Manganese) |
- |
600 |
|
- |
| 4.1,
Table 1of IS:740 (Designation 65032)(Silicon) |
- |
600 |
|
- |
| 4.1,
Table 1of IS:740 (Designation 65032)(Zinc) |
- |
600 |
|
- |
| 4.1,
Table 1of IS:740 (Designation 64430)(Chromium) |
- |
600 |
|
- |
| 4.1,
Table 1of IS:740 (Designation 55000)(Chromium) |
- |
600 |
|
- |
| 4.1,
Table 1of IS:740 (Designation 53000)(Chromium) |
- |
600 |
|
- |
| 4.1,
Table 1of IS:740 (Designation 24345)(Chromium) |
- |
600 |
|
- |
| 4.1,
Table 1of IS:740 (Designation 64430)(Copper) |
- |
600 |
|
- |
| 4.1,
Table 1of IS:740 (Designation 55000)(Copper) |
- |
600 |
|
- |
| 4.1,
Table 1of IS:740 (Designation 53000)(Copper) |
- |
600 |
|
- |
| 4.1,
Table 1of IS:740 (Designation 24345)(Copper) |
- |
600 |
|
- |
| 4.1,
Table 1of IS:740 (Designation 19000)(Copper) |
- |
600 |
|
- |
| 4.1,
Table 1of IS:740 (Designation 64430)(Iron) |
- |
600 |
|
- |
| 4.1,
Table 1of IS:740 (Designation 55000)(Iron) |
- |
600 |
|
- |
| 4.1,
Table 1of IS:740 (Designation 53000)(Iron) |
- |
600 |
|
- |
| 4.1,
Table 1of IS:740 (Designation 24345)(Iron) |
- |
600 |
|
- |
| 4.1,
Table 1of IS:740 (Designation 19000)(Iron) |
- |
600 |
|
- |
| 4.1,
Table 1of IS:740 (Designation 64430)(Magnesium) |
- |
600 |
|
- |
| 4.1,
Table 1of IS:740 (Designation 55000)(Magnesium) |
- |
600 |
|
- |
| 4.1,
Table 1of IS:740 (Designation 53000)(Magnesium) |
- |
600 |
|
- |
| 4.1,
Table 1of IS:740 (Designation 24345)(Magnesium) |
- |
600 |
|
- |
| 4.1,
Table 1of IS:740 (Designation 19000)(Magnesium) |
- |
600 |
|
- |
| 4.1,
Table 1of IS:740 (Designation 64430)(Manganese) |
- |
600 |
|
- |
| 4.1,
Table 1of IS:740 (Designation 55000)(Manganese) |
- |
600 |
|
- |
| 4.1,
Table 1of IS:740 (Designation 53000)(Manganese) |
- |
600 |
|
- |
| 4.1,
Table 1of IS:740 (Designation 24345)(Manganese) |
- |
600 |
|
- |
| 4.1,
Table 1of IS:740 (Designation 19000)(Manganese) |
- |
600 |
|
- |
| 4.1,
Table 1of IS:740 (Designation 64430)(Silicon) |
- |
600 |
|
- |
| 4.1,
Table 1of IS:740 (Designation 55000)(Silicon) |
- |
600 |
|
- |
| 4.1,
Table 1of IS:740 (Designation 53000)(Silicon) |
- |
600 |
|
- |
| 4.1,
Table 1of IS:740 (Designation 24345)(Silicon) |
- |
600 |
|
- |
| 4.1,
Table 1of IS:740 (Designation 19000)(Silicon) |
- |
600 |
|
- |
| 4.1,
Table 1of IS:740 (Designation 64430)(Zinc) |
- |
600 |
|
- |
| 4.1,
Table 1of IS:740 (Designation 55000)(Zinc) |
- |
600 |
|
- |
| 4.1,
Table 1of IS:740 (Designation 53000)(Zinc) |
- |
600 |
|
- |
| 4.1,
Table 1of IS:740 (Designation 24345)(Zinc) |
- |
600 |
|
- |
| 4.1,
Table 1of IS:740 (Designation 19000)(Zinc) |
- |
600 |
|
- |
| 4.1,
Table 1of IS:740 (Designation & Condition 65032, 'W')(Tensile Strength of Size upto and including 25 mm) |
- |
2000 |
|
- |
| 4.1,
Table 1of IS:740 (Designation & Condition 64430, 'W')(Tensile Strength of Size upto and including 25 mm) |
- |
2000 |
|
- |
| 4.1,
Table 1of IS:740 (Designation & Condition 55000, 'OD')(Tensile Strength of Size upto and including 25 mm) |
- |
2000 |
|
- |
| 4.1,
Table 1of IS:740 (Designation & Condition 55000, 'O or M')(Tensile Strength of Size upto and including 25 mm) |
- |
2000 |
|
- |
| 4.1,
Table 1of IS:740 (Designation & Condition 53000, 'OD')(Tensile Strength of Size upto and including 25 mm) |
- |
2000 |
|
- |
| 4.1,
Table 1of IS:740 (Designation & Condition 53000, 'O or M')(Tensile Strength of Size upto and including 25 mm) |
- |
2000 |
|
- |
| 4.1,
Table 1of IS:740 (Designation & Condition 24345, 'W')(Tensile Strength of Size upto and including 12 mm) |
- |
2000 |
|
- |
| 4.1,
Table 1of IS:740 (Designation & Condition 19000, '112')(Tensile Strength of Size upto and including 12 mm) |
- |
2000 |
|
- |
| 6(Freedom From Defects) |
- |
500 |
|
- |
| 7(Dmension And Tolerances) |
- |
500 |
|
- |
| 9.2(Head Forming Test) |
- |
1500 |
|
- |
| 11(Marking) |
- |
200 |
|
- |
|
- |
- - |
| 7086 |
URS PRODUCTS AND TESTING PVT. LTD. (A29), NOIDA
| 8168906
| IS 739 (1992) |
Wrought aluminium and aluminium alloys - Wire for general engineering purposes - Specification (Third Revision) |
- |
11000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 6.0(Freedom from defects) |
- |
300 |
|
- |
| 7.0(Dimension and Tolerances) |
- |
500 |
|
- |
| 8.1 Table-1(Al) |
- |
800 |
|
- |
| 8.1 Table-1(Cu) |
- |
800 |
|
- |
| 8.1 Table-1(Mg) |
- |
800 |
|
- |
| 8.1 Table-1(Si) |
- |
800 |
|
- |
| 8.1 Table-1(Fe) |
- |
800 |
|
- |
| 8.1 Table-1(Mn) |
- |
800 |
|
- |
| 8.1 Table-1(Zn) |
- |
800 |
|
- |
| 8.1 Table-1(Ti) |
- |
800 |
|
- |
| 8.1 Table-1(Cr) |
- |
800 |
|
- |
| 9.1(Tensile Strength) |
- |
2500 |
|
- |
| 9.3(Wrapping Test) |
- |
1500 |
|
- |
| 10(Selection of Test Samples) |
- |
500 |
|
- |
|
- |
- - |
| 7087 |
URS PRODUCTS AND TESTING PVT. LTD. (A29), NOIDA
| 8168906
| IS 737 (2008) |
Wrought aluminium and aluminium alloy sheet and strip for general engineering purposes - Specification (Fourth Revision) |
- |
9000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 5.0(Freedom from defects) |
- |
200 |
|
- |
| 6 Table-1(Al) |
- |
500 |
|
- |
| 6 Table-1(Cr) |
- |
500 |
|
- |
| 6 Table-1(Cu) |
- |
500 |
|
- |
| 6 Table-1(Mg) |
- |
500 |
|
- |
| 6 Table-1(Mn) |
- |
500 |
|
- |
| 6 Table-1(Si) |
- |
500 |
|
- |
| 6 Table-1(Fe) |
- |
500 |
|
- |
| 6 Table-1(Zn) |
- |
500 |
|
- |
| 6 Table-1(Ti) |
- |
500 |
|
- |
| 6 Table-1(Cu+Si+Fe) |
- |
500 |
|
- |
| 6 Table-1(Cu+Si+Fe+Mn+Zn) |
- |
500 |
|
- |
| 6 Table-1(Cu+Mg+Si+Fe+Mn+Zn) |
- |
500 |
|
- |
| 6 Table-1(Zr) |
- |
500 |
|
- |
| 6 Table-1(Cr+Mn) |
- |
500 |
|
- |
| 7 Table-2(Tensile Strength) |
- |
1000 |
|
- |
| 7 Table-2(Elongation) |
- |
1000 |
|
- |
| 7 Table-2(0.2 % Proof Stress) |
- |
1300 |
|
- |
| 7 Table-2(Bend Test) |
- |
900 |
|
- |
| 9(Dimension - IS 2676) |
- |
500 |
|
- |
| 12(Marking) |
- |
300 |
|
- |
|
- |
- - |
| 7088 |
URS PRODUCTS AND TESTING PVT. LTD. (A29), NOIDA
| 8168906
| IS 733 (1983) |
Specification for wrought aluminium and aluminium alloy bars, rods and sections (For General Engineering Purposes) (Third Revision) |
- |
8000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl. 4(Freedom from Defects) |
- |
200 |
|
- |
| Cl. 5.1, Table 2(Tensile Strength- IS 1816) |
- |
1000 |
|
- |
| Cl. 5.1, Table 2(Elongation on 50 mm or 5.65√So Gauge Length) |
- |
1000 |
|
- |
| Cl. 5.1, Table 2(0.2 Percent proof stress- IS 1816) |
- |
1300 |
|
- |
| Cl. 0.4, 5.1, Table 1(Aluminium- IS 504 or by any other suitable instrumental method) |
- |
500 |
|
- |
| Cl. 0.4, 5.1, Table 1(Chromium- IS 504 or by any other suitable instrumental method) |
- |
500 |
|
- |
| Cl. 0.4, 5.1, Table 1(Copper- IS 504 or by any other suitable instrumental method) |
- |
500 |
|
- |
| Cl. 0.4, 5.1, Table 1(Magnesium- IS 504 or by any other suitable instrumental method) |
- |
500 |
|
- |
| Cl. 0.4, 5.1, Table 1(Silicon- IS 504 or by any other suitable instrumental method) |
- |
500 |
|
- |
| Cl. 0.4, 5.1, Table 1(Iron- IS 504 or by any other suitable instrumental method) |
- |
500 |
|
- |
| Cl. 0.4, 5.1, Table 1(Zinc- IS 504 or by any other suitable instrumental method) |
- |
500 |
|
- |
| Cl. 0.4, 5.1, Table 1(Titanium and / or other grain refining elements - IS 504 or by any other suitable instrumental method) |
- |
500 |
|
- |
| Cl. 0.4, 5.1, Table 1(Ti+ V- IS 504 or by any other suitable instrumental method) |
- |
500 |
|
- |
| Cl. 0.4, 5.1, Table 1(Total Impurities- IS 504 or by any other suitable instrumental method) |
- |
500 |
|
- |
| Cl. 0.4, 5.1, Table 1(Cr+ Mn- IS 504 or by any other suitable instrumental method) |
- |
500 |
|
- |
| 7(Dimension - IS 3965) |
- |
400 |
|
- |
| 11(Marking) |
- |
300 |
|
- |
| Cl. 4(Freedom from Defects) |
- |
- |
|
- |
| Cl. 5.1, Table 2(Tensile Strength- IS 1816) |
- |
- |
|
- |
| Cl. 5.1, Table 2(Elongation on 50 mm or 5.65√So Gauge Length) |
- |
- |
|
- |
| Cl. 5.1, Table 2(0.2 Percent proof stress- IS 1816) |
- |
- |
|
- |
| Cl. 0.4, 5.1, Table 1(Aluminium- IS 504 or by any other suitable instrumental method) |
- |
- |
|
- |
| Cl. 0.4, 5.1, Table 1(Chromium- IS 504 or by any other suitable instrumental method) |
- |
- |
|
- |
| Cl. 0.4, 5.1, Table 1(Copper- IS 504 or by any other suitable instrumental method) |
- |
- |
|
- |
| Cl. 0.4, 5.1, Table 1(Magnesium- IS 504 or by any other suitable instrumental method) |
- |
- |
|
- |
| Cl. 0.4, 5.1, Table 1(Silicon- IS 504 or by any other suitable instrumental method) |
- |
- |
|
- |
| Cl. 0.4, 5.1, Table 1(Iron- IS 504 or by any other suitable instrumental method) |
- |
- |
|
- |
| Cl. 0.4, 5.1, Table 1(Zinc- IS 504 or by any other suitable instrumental method) |
- |
- |
|
- |
| Cl. 0.4, 5.1, Table 1(Titanium and / or other grain refining elements - IS 504 or by any other suitable instrumental method) |
- |
- |
|
- |
| Cl. 0.4, 5.1, Table 1(Ti+ V- IS 504 or by any other suitable instrumental method) |
- |
- |
|
- |
| Cl. 0.4, 5.1, Table 1(Total Impurities- IS 504 or by any other suitable instrumental method) |
- |
- |
|
- |
| Cl. 0.4, 5.1, Table 1(Cr+ Mn- IS 504 or by any other suitable instrumental method) |
- |
- |
|
- |
| 7(Dimension - IS 3965) |
- |
- |
|
- |
| 11(Marking) |
- |
- |
|
- |
|
- |
- - |
| 7089 |
URS PRODUCTS AND TESTING PVT. LTD. (A29), NOIDA
| 8168906
| IS 13983 (1994) |
Stainless Steel Sinks For Domestic Purposes |
- |
7000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4(Type) |
- |
200 |
|
- |
| Cl. 5 , As per IS 5522-2014, Cl. 7.2 , Table 1 & 2 Grade Desig X-04-Cr-19-Ni-19 (Numeric Symbol 304)(Carbon Content) |
- |
300 |
|
- |
| Cl. 5 , As per IS 5522-2014, Cl. 7.2 , Table 1 & 2 Grade Desig X-04-Cr-19-Ni-19 (Numeric Symbol 304)(Silicon Content) |
- |
300 |
|
- |
| Cl. 5 , As per IS 5522-2014, Cl. 7.2 , Table 1 & 2 Grade Desig X-04-Cr-19-Ni-19 (Numeric Symbol 304)(Manganese Content) |
- |
300 |
|
- |
| Cl. 5 , As per IS 5522-2014, Cl. 7.2 , Table 1 & 2 Grade Desig X-04-Cr-19-Ni-19 (Numeric Symbol 304)(Nickel Content) |
- |
300 |
|
- |
| Cl. 5 , As per IS 5522-2014, Cl. 7.2 , Table 1 & 2 Grade Desig X-04-Cr-19-Ni-19 (Numeric Symbol 304)(Chromium Content) |
- |
300 |
|
- |
| Cl. 5 , As per IS 5522-2014, Cl. 7.2 , Table 1 & 2 Grade Desig X-04-Cr-19-Ni-19 (Numeric Symbol 304)(Sulphur Content) |
- |
300 |
|
- |
| Cl. 5 , As per IS 5522-2014, Cl. 7.2 , Table 1 & 2 Grade Desig X-04-Cr-19-Ni-19 (Numeric Symbol 304)(Phouphorous Content) |
- |
300 |
|
- |
| Cl. 5 , As per IS 5522-2014, Cl. 7.2 , Table 1 & 2 Grade Desig X-04-Cr-19-Ni-19 (Numeric Symbol 304)(Nitrogen Content) |
- |
300 |
|
- |
| Cl. 5 , As per IS 5522-2014, Cl. 7.2 , Table 1 & 2 Grade Desig X-07-Cr-18-Ni-9 (Numeric Symbol 302)(Carbon Content) |
- |
300 |
|
- |
| Cl. 5 , As per IS 5522-2014, Cl. 7.2 , Table 1 & 2 Grade Desig X-07-Cr-18-Ni-9 (Numeric Symbol 302)(Silicon Content) |
- |
300 |
|
- |
| Cl. 5 , As per IS 5522-2014, Cl. 7.2 , Table 1 & 2 Grade Desig X-07-Cr-18-Ni-9 (Numeric Symbol 302)(Manganese Content) |
- |
300 |
|
- |
| Cl. 5 , As per IS 5522-2014, Cl. 7.2 , Table 1 & 2 Grade Desig X-07-Cr-18-Ni-9 (Numeric Symbol 302)(Nickel Content) |
- |
300 |
|
- |
| Cl. 5 , As per IS 5522-2014, Cl. 7.2 , Table 1 & 2 Grade Desig X-07-Cr-18-Ni-9 (Numeric Symbol 302)(Chromium Content) |
- |
300 |
|
- |
| Cl. 5 , As per IS 5522-2014, Cl. 7.2 , Table 1 & 2 Grade Desig X-07-Cr-18-Ni-9 (Numeric Symbol 302)(Sulphur Content) |
- |
300 |
|
- |
| Cl. 5 , As per IS 5522-2014, Cl. 7.2 , Table 1 & 2 Grade Desig X-07-Cr-18-Ni-9 (Numeric Symbol 302)(Phouphorous Content) |
- |
300 |
|
- |
| Cl. 5 , As per IS 5522-2014, Cl. 7.2 , Table 1 & 2 Grade Desig X-07-Cr-18-Ni-9 (Numeric Symbol 302)(Nitrogen Content) |
- |
300 |
|
- |
| 6(Thickness of sheet/strip) |
- |
400 |
|
- |
| 6(Depth of bowl) |
- |
400 |
|
- |
| 6(Internal dimensions of the bowl) |
- |
400 |
|
- |
| 6.4.1(Bowl Locating Limits) |
- |
400 |
|
- |
| 6(Co-ordinating sizes) |
- |
400 |
|
- |
| 7.1(Consruction and workmanship) |
- |
400 |
|
- |
| 7.1.1(Consruction and workmanship) |
- |
400 |
|
- |
| 7.2(Consruction and workmanship) |
- |
400 |
|
- |
| 7.2.1(Consruction and workmanship) |
- |
400 |
|
- |
| 7.3(CONSTRUCTION AND WORKMANSHIP) |
- |
400 |
|
- |
| 7.4(Waste Outlet) |
- |
400 |
|
- |
| 7.5(Tap holes) |
- |
400 |
|
- |
| 7.6(OVERFLOW) |
- |
400 |
|
- |
| 8(Finish) |
- |
400 |
|
- |
|
- |
- - |
| 7090 |
URS PRODUCTS AND TESTING PVT. LTD. (A29), NOIDA
| 8168906
| IS 7231 (2021) |
Plastic flushing cisterns for water closets and urinals - Specification (third revision) |
- |
15000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 5.1.1(Construction of Exposed Cistern) |
- |
200 |
|
5% discount for BIS |
| 5.1.1(Construction of Exposed Cistern) |
- |
200 |
|
5% discount for BIS |
| 5.1.1(Construction of Exposed Cistern) |
- |
200 |
|
5% discount for BIS |
| 5.1.2(Construction of Cover) |
- |
200 |
|
5% discount for BIS |
| 5.1.3(Construction of Flush Pipe) |
- |
200 |
|
5% discount for BIS |
| 5.1.3.1(Flush pipe connection to cistern) |
- |
200 |
|
5% discount for BIS |
| 5.1.3.1(Flush pipe connection to cistern) |
- |
200 |
|
5% discount for BIS |
| 5.1.3.1(Flush pipe connection to cistern) |
- |
200 |
|
5% discount for BIS |
| 5.1.3.1(Flush pipe connection to cistern) |
- |
200 |
|
5% discount for BIS |
| 5.1.4(Inlet and Overflow Holes) |
- |
200 |
|
5% discount for BIS |
| 5.1.5(Float Valve) |
- |
200 |
|
5% discount for BIS |
| 5.1.6(Operating Mechanism (Push-Knob)) |
- |
200 |
|
5% discount for BIS |
| 5.1.6(Operating Mechanism (Push-Knob)) |
- |
200 |
|
5% discount for BIS |
| 5.1.7(Overflow Pipe) |
- |
200 |
|
5% discount for BIS |
| 5.1.7.2(Overflow Pipe) |
- |
200 |
|
5% discount for BIS |
| 5.1.7.3(Overflow Pipe) |
- |
200 |
|
5% discount for BIS |
| 5.2.1(Concealed Cistern) |
- |
200 |
|
5% discount for BIS |
| 5.2.1(Concealed Cistern- Construction) |
- |
200 |
|
5% discount for BIS |
| 5.2.2(Flush Pipe) |
- |
200 |
|
5% discount for BIS |
| 5.2.3(Operating Mechanism) |
- |
200 |
|
5% discount for BIS |
| 5.2.3(Operating Mechanism) |
- |
200 |
|
5% discount for BIS |
| 6, 6.1(Finish) |
- |
200 |
|
5% discount for BIS |
| 6.1(Finish) |
- |
200 |
|
5% discount for BIS |
| 6.1(Finish) |
- |
800 |
|
5% discount for BIS |
| 6.2(Finish) |
- |
800 |
|
5% discount for BIS |
| 7.1(Operational and Performance Requirement- Flushing Arrangement) |
- |
300 |
|
5% discount for BIS |
| 7.2(Working Water Level) |
- |
300 |
|
5% discount for BIS |
| 7.3(Freedom from Leakage) |
- |
300 |
|
5% discount for BIS |
| 7.4(Reduced Water Level) |
- |
300 |
|
5% discount for BIS |
| 7.5 (a)(Cistern Discharge Capacity 6/3 Litres) |
- |
600 |
|
5% discount for BIS |
| 7.5 (a)(Cistern Discharge Capacity 6/3 Litres) |
- |
600 |
|
5% discount for BIS |
| 7.5 (b)(Cistern Discharge Capacity 4.8/2.8 litres) |
- |
600 |
|
5% discount for BIS |
| 7.5 (b)(Cistern Discharge Capacity 4.8/2.8 litres) |
- |
600 |
|
5% discount for BIS |
| 7.5 (c)(Cistern Discharge Capacity 4/2 litres) |
- |
600 |
|
5% discount for BIS |
| 7.5 (c)(Cistern Discharge Capacity 4/2 litres) |
- |
600 |
|
5% discount for BIS |
| 7.6 (a)(Discharge Rate) |
- |
900 |
|
5% discount for BIS |
| 7.6 (b)(Discharge Rate) |
- |
900 |
|
5% discount for BIS |
| 7.6 (c)(Discharge Rate) |
- |
900 |
|
5% discount for BIS |
| 7.6(Discharge Rate) |
- |
900 |
|
5% discount for BIS |
| 8.1(Distortion Resistance Test) |
- |
500 |
|
5% discount for BIS |
| 8.2(Dead Load Test) |
- |
800 |
|
5% discount for BIS |
| 8.3(Front Thrust Test) |
- |
800 |
|
5% discount for BIS |
| 8.4(Impact Test) |
- |
900 |
|
5% discount for BIS |
| 8.4.1(Impact Test) |
- |
900 |
|
5% discount for BIS |
| 9.3(Endurance Test) |
- |
3000 |
|
5% discount for BIS |
|
- |
- - |
| 7091 |
Ace Test Labs & Metrology Pvt. Ltd., Sonipat
| 9162826
| IS 14203 (2023) |
FIRE RESISTING RECORD PROTECTION CABINETS SPECIFICATION Second Revision of IS 14203 |
- |
198000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 3 and 6 (Table 1)(Nominal Sizes - Height) |
- |
20000 |
|
- |
| 3 and 6 (Table 1)(Nominal Sizes - Width) |
- |
20000 |
|
- |
| 3 and 6 (Table 1)(Nominal Sizes - Depth) |
- |
20000 |
|
- |
| 3 and 6 (Table 1)(Height of Pedestal) |
- |
20000 |
|
- |
| 7(Designation) |
- |
20000 |
|
- |
| 8.1(Cabinet Construction) |
- |
20000 |
|
- |
| 8.2(Locking Mechanism) |
- |
100000 |
|
- |
| 8.3(Locks) |
- |
20000 |
|
- |
| 8.4(Handles) |
- |
20000 |
|
- |
| 9(Internal Fixtures) |
- |
20000 |
|
- |
| 10.1(Minimum overall thinckness of coating) |
- |
20000 |
|
- |
| 10.2(Cross Hatch Test) |
- |
20000 |
|
- |
| 11, Annex-B, 3.1(Fire Endurance Test) |
- |
120000 |
|
- |
| 11, Annex-B, 3.2(Fire and Impact test) |
- |
100000 |
|
- |
| 3 and 6 (Table 1)(Nominal Sizes - Height) |
- |
20000 |
|
- |
| 3 and 6 (Table 1)(Nominal Sizes - Width) |
- |
20000 |
|
- |
| 3 and 6 (Table 1)(Nominal Sizes - Depth) |
- |
20000 |
|
- |
| 3 and 6 (Table 1)(Height of Pedestal) |
- |
20000 |
|
- |
| 7(Designation) |
- |
20000 |
|
- |
| 8.1(Cabinet Construction) |
- |
20000 |
|
- |
| 8.2(Locking Mechanism) |
- |
20000 |
|
- |
| 8.3(Locks) |
- |
20000 |
|
- |
| 8.4(Handles) |
- |
20000 |
|
- |
| 9(Internal Fixtures) |
- |
20000 |
|
- |
| 10.1(Minimum overall thinckness of coating) |
- |
20000 |
|
- |
| 10.2(Cross Hatch Test) |
- |
20000 |
|
- |
| 11, Annex-B, 3.1(Fire Endurance Test) |
- |
120000 |
|
- |
| 11, Annex-B, 3.2(Fire and Impact test) |
- |
100000 |
|
- |
|
14 Nov, 2027 |
- - |
| 7092 |
Atmy Analytical Labs Private Limited (Unit-2), Greater Noida
| 8176106
| IS 14203 (2023) |
FIRE RESISTING RECORD PROTECTION CABINETS SPECIFICATION Second Revision of IS 14203 |
- |
339000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 3 and 6 (Table 1)(Nominal Sizes - Height) |
- |
0 |
|
- |
| 3 and 6 (Table 1)(Nominal Sizes - Width) |
- |
0 |
|
- |
| 3 and 6 (Table 1)(Nominal Sizes - Depth) |
- |
0 |
|
- |
| 3 and 6 (Table 1)(Height of Pedestal) |
- |
0 |
|
- |
| 7(Designation) |
- |
0 |
|
- |
| 8.1(Cabinet Construction) |
- |
0 |
|
- |
| 8.2(Locking Mechanism) |
- |
0 |
|
- |
| 8.3(Locks) |
- |
0 |
|
- |
| 8.4(Handles) |
- |
0 |
|
- |
| 9(Internal Fixtures) |
- |
0 |
|
- |
| 10.1(Minimum overall thinckness of coating) |
- |
0 |
|
- |
| 10.2(Cross Hatch Test) |
- |
0 |
|
- |
| 11, Annex-B, 3.1(Fire Endurance Test) |
- |
0 |
|
- |
| 11, Annex-B, 3.2(Fire and Impact test) |
- |
0 |
|
- |
|
08 Feb, 2027 |
- Included w.e.f. 01.04.2025 |
| 7093 |
Atmy Analytical Labs Private Limited (Unit-2), Greater Noida
| 8176106
| IS 14561 (2014) |
Fire resisting (Insulating) filing cabinets - Specification (Second Revision) |
ALL |
330000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 3(Types & Rating) |
- |
0 |
|
- |
| 3.1(i) The fire resisting filing cabinets shall be of two types:
a) Vertical fire resisting filing cabinet, and
b) Lateral fire resisting filing cabinet.) |
- |
0 |
|
- |
| 3.2(ii) The standard and lateral fire resisting filing
cabinets shall have one-drawer or two-drawers or three drawers or four-drawers. A typical drawing of the fire resisting filing cabinet is given in Fig. 1.) |
- |
0 |
|
- |
| 3.3(iii) The fire resisting filing cabinets shall have fire
resisting ratings of 60 min or 120 min or 180 min or
240 min) |
- |
0 |
|
- |
| 4(Dimensions and Tolerances, mm) |
- |
0 |
|
- |
| 4.1(Overall Dimensions of Fire Resisting Filing
Cabinets: The internal usable space of the drawers of fire resisting (insulating) filing cabinets shall be as specified in Table 1 or any other size which is mutually agreed to between the purchaser and the supplier.) |
- |
0 |
|
- |
| 4.1(Internal usuable space of drawer, mm:) |
- |
0 |
|
- |
| 4.1(i) Height) |
- |
0 |
|
- |
| 4.1(ii) Width) |
- |
0 |
|
- |
| 4.1(iii) Depth) |
- |
0 |
|
- |
| 4.1(iv) Height of the bottom drawer above floor level) |
- |
0 |
|
- |
| 5(Materials) |
- |
0 |
|
- |
| 6(Designations: The filing cabinet shall be designated by the commonly used name, type, the fire rating and the number of this Indian Standard.) |
- |
0 |
|
- |
| 7(Constructions) |
- |
0 |
|
- |
| 7.1(Outer body and Inner Box: Outer body and inner box shall be fabricated from mild steel or galvanized steel sheets of not less than 0.8 mm and not more than 1.2 mm nominal thickness. The steel shall not have any burrs or dents. If required the outer
body shall be suitably stiffened to avoid bulging) |
- |
0 |
|
- |
| 7.2(Cabinets Sub-Assembly: The external body and drawer fronts of the fire resisting (insulating) filing cabinet shall be of double wall type with homogeneous insulating material filled in
between. Further the construction of the cabinet shall be such that each drawer slides in an individual inner box. The inner boxes shall have a insulating layer between each other to prevent fire spreading from one drawer to another. The joining of inner box, intermediate piece and outer body shall be such that, it forms a cavity to receive drawer front ) |
- |
0 |
|
- |
| 7.3(Filing Drawer: The drawer shall be made from mild steel or galvanized steel sheet of not less than 0.6 mm and not more than 1.0 mm nominal thickness and shall have an arrangement on the sides suitable for the drawer suspension system and an arrangement to stop it when fully pushed in.) |
- |
0 |
|
- |
| 7.3.1(Drawer Front: The drawer front shall be made from mild steel or galvanized steel sheet of not less than 0.6 mm and not more than 1.0 mm nominal thickness and shall be firmly secured to the drawer body by welding, screwing or riveting or any combination of these processes. The construction of drawer front shall be such that it snugly fits in the cavity provided for the same ) |
- |
0 |
|
- |
| 7.4.1(Latch: Each drawer of the cabinet shall be removable but shall be fitted with a latch/positive stop to prevent inadvertent withdrawal and rebound. Such latch shall be lifted/unlocked by the pull of the handle or any other mechanism.) |
- |
0 |
|
- |
| 7.4.2(The locking mechanism shall be designed in such
a manner so that there is minimum passage for direct
conduction of heat from outside to inside) |
- |
0 |
|
- |
| 7.5(Drawer Suspension The drawer suspension shall be either of the following types to ensure withdrawal of the full depth of the drawer:
a) Ball bearing / Roller bearing suspension
(Movement),
b) Solid roller suspension, and
c) Telescopic slide suspension (Extension) |
- |
0 |
|
- |
| 7.6(Handles: Each drawer shall be provided either with a handle made from ferrous/non-ferrous material suitably coated for corrosion resistance, or any polymer and fixed to the front of the drawer or with a built in pulling mechanism) |
- |
0 |
|
- |
| 7.6.1(The drawer handle shall be strong enough to take
a minimum pull of 50 N for 2 min. There shall be no
sharp corners or edges to avoid injury and damage to clothing) |
- |
0 |
|
- |
| 7.7.1(Locks: Top drawer shall be provided with single or dual control key lock having not less than 6 levers or pin cylinder lock having not less than 6 pins, with duplicate keys of stainless steel/nonferrous alloy. Alternatively if required by the purchaser a 3 wheel combination lock or electronic combination lock may be provided either in place of key lock or in addition to key lock) |
- |
0 |
|
- |
| 7.7.2(Each drawer may also be provided with
individual key lock or pin cylinder lock or combination lock subject to agreement between the purchaser and the supplier.) |
- |
0 |
|
- |
| 7.8(Locking Mechanism ) |
- |
0 |
|
- |
| 7.8.1(The locking mechanism shall be such that when
the top drawer is pushed-in fully, it actuates locking
mechanism to lock all other drawers imultaneously,
when they are in pushed-in position) |
- |
0 |
|
- |
| 7.8.1.1(At the time of locking the cabinet, if one of the
drawers is not fully pushed-in, that drawer shall remain unlocked and can be used. As soon as that drawer is pushed-in fully, it shall get locked automatically without further operation of key by the user.) |
- |
0 |
|
- |
| 7.8.1.2(In addition to the above, isolation mechanism
shall also be provided to permit independent locking/ use of other drawers. Such isolation mechanism provided on drawers shall be manually operated) |
- |
0 |
|
- |
| 8(Assemblies) |
- |
0 |
|
- |
| 8.1(The components shall be assembled by bolting,
welding, riveting or by any combination of these
processes) |
- |
0 |
|
- |
| 8.2(All joints between outer body and inner boxes,
the drawer front and the outer body shall be such that, there is minimum direct conduction of heat from outer body to inner body) |
- |
0 |
|
- |
| 9.1(Drawer Suspension Test and Latch Test: The drawer loaded with evenly distributed load of 30 kg
(excluding the weight of drawer) in any drawer shall be operated for 5 000 cycles at a rate of 300 cycles/h ±10 percent. One opening and one closing shall constitute one cycle. The test shall be carried out with maximum two breaks by using electrically or mechanically operated test equipment with a counter fitted on it. After 5 000 cycles the suspension slide and latch mechanism shall not show any apparent distortion, cracks, or failures to operate in a normal smooth manner) |
- |
0 |
|
- |
| 10.1(Finish: All dents, burrs and sharp edges shall be removed from the various components and they shall be thoroughly degreased and cleaned of rust and scale) |
- |
0 |
|
- |
| 10.2(The inside and outside surfaces of the fire resisting
(Insulating) filing cabinet shall be painted or powder coated. In case of paint, an appropriate primer and undercoating shall be used in accordance to industry practices. The minimum overall thickness of the coatings shall be 50 μ for powder coating and 70 μ for liquid paint. Cross hatch test shall be conducted to confirm the adhesion of coating in accordance with 10.2.1) |
- |
0 |
|
- |
| 10.2.1(Cross Hatch Test) |
- |
0 |
|
- |
| 10.2.1(a) Make 6 parallel cut marks using sharp metal
pointer and straight edge, through the painted/
coated surface, so as to make the base surface
visible through cut marks) |
- |
0 |
|
- |
| 10.2.1(b) Cut marks shall be minimum 20 mm long and
at 2 mm distance from each other) |
- |
0 |
|
- |
| 10.2.1(c) Make 6 similar cut marks in the direction
perpendicular to first set of cut marks, with
same length and spacing) |
- |
0 |
|
- |
| 10.2.1(d) These 12 cut marks together shall make a
pattern of 25 squares of 2 mm × 2mm size,
totally separated from each other) |
- |
0 |
|
- |
| 10.2.1(f) To ensure continuous contact with paint/coat
film, rub the tape firmly and remove air
bubbles under the tape, if any) |
- |
0 |
|
- |
| 10.2.1(g)Within 60 to 120 s after sticking the tape,
remove it by seizing free end of the tape and
rapidly pulling it off at an angle close to 180°.) |
- |
0 |
|
- |
| 10.2.1(h) Painting/Coating quality is considered as
acceptable, if no part of any 2 mm × 2 mm
square of paint/coat comes off the surface due
to pulling the tape) |
- |
0 |
|
- |
| 11.1(Fire endurance test) |
- |
0 |
|
- |
| 11.2(Fire and impact test) |
- |
0 |
|
- |
| 12.1(Marking of Cabinets:A metal plate showing classification of cabinet together with the manufacturer’s name, serial number and the
year of manufacture shall be fixed inside surface of
the top drawer of the cabinet in such a way that it is
visible when it is opened.) |
- |
0 |
|
- |
| 12.2(Marking on Keys: The keys shall bear an identification number which shall not be the same as the serial number of the cabinet) |
- |
0 |
|
- |
| 3(Types & Rating) |
- |
0 |
|
- |
| 3.1(i) The fire resisting filing cabinets shall be of two types:
a) Vertical fire resisting filing cabinet, and
b) Lateral fire resisting filing cabinet.) |
- |
0 |
|
- |
| 3.2(ii) The standard and lateral fire resisting filing
cabinets shall have one-drawer or two-drawers or three drawers or four-drawers. A typical drawing of the fire resisting filing cabinet is given in Fig. 1.) |
- |
0 |
|
- |
| 3.3(iii) The fire resisting filing cabinets shall have fire
resisting ratings of 60 min or 120 min or 180 min or
240 min) |
- |
0 |
|
- |
| 4(Dimensions and Tolerances, mm) |
- |
0 |
|
- |
| 4.1(Overall Dimensions of Fire Resisting Filing
Cabinets: The internal usable space of the drawers of fire resisting (insulating) filing cabinets shall be as specified in Table 1 or any other size which is mutually agreed to between the purchaser and the supplier.) |
- |
0 |
|
- |
| 4.1(Internal usuable space of drawer, mm:) |
- |
0 |
|
- |
| 4.1(i) Height) |
- |
0 |
|
- |
| 4.1(ii) Width) |
- |
0 |
|
- |
| 4.1(iii) Depth) |
- |
0 |
|
- |
| 4.1(iv) Height of the bottom drawer above floor level) |
- |
0 |
|
- |
| 5(Materials) |
- |
0 |
|
- |
| 6(Designations: The filing cabinet shall be designated by the commonly used name, type, the fire rating and the number of this Indian Standard.) |
- |
0 |
|
- |
| 7(Constructions) |
- |
0 |
|
- |
| 7.1(Outer body and Inner Box: Outer body and inner box shall be fabricated from mild steel or galvanized steel sheets of not less than 0.8 mm and not more than 1.2 mm nominal thickness. The steel shall not have any burrs or dents. If required the outer
body shall be suitably stiffened to avoid bulging) |
- |
0 |
|
- |
| 7.2(Cabinets Sub-Assembly: The external body and drawer fronts of the fire resisting (insulating) filing cabinet shall be of double wall type with homogeneous insulating material filled in
between. Further the construction of the cabinet shall be such that each drawer slides in an individual inner box. The inner boxes shall have a insulating layer between each other to prevent fire spreading from one drawer to another. The joining of inner box, intermediate piece and outer body shall be such that, it forms a cavity to receive drawer front ) |
- |
0 |
|
- |
| 7.3(Filing Drawer: The drawer shall be made from mild steel or galvanized steel sheet of not less than 0.6 mm and not more than 1.0 mm nominal thickness and shall have an arrangement on the sides suitable for the drawer suspension system and an arrangement to stop it when fully pushed in.) |
- |
0 |
|
- |
| 7.3.1(Drawer Front: The drawer front shall be made from mild steel or galvanized steel sheet of not less than 0.6 mm and not more than 1.0 mm nominal thickness and shall be firmly secured to the drawer body by welding, screwing or riveting or any combination of these processes. The construction of drawer front shall be such that it snugly fits in the cavity provided for the same ) |
- |
0 |
|
- |
| 7.4.1(Latch: Each drawer of the cabinet shall be removable but shall be fitted with a latch/positive stop to prevent inadvertent withdrawal and rebound. Such latch shall be lifted/unlocked by the pull of the handle or any other mechanism.) |
- |
0 |
|
- |
| 7.4.2(The locking mechanism shall be designed in such
a manner so that there is minimum passage for direct
conduction of heat from outside to inside) |
- |
0 |
|
- |
| 7.5(Drawer Suspension The drawer suspension shall be either of the following types to ensure withdrawal of the full depth of the drawer:
a) Ball bearing / Roller bearing suspension
(Movement),
b) Solid roller suspension, and
c) Telescopic slide suspension (Extension) |
- |
0 |
|
- |
| 7.6(Handles: Each drawer shall be provided either with a handle made from ferrous/non-ferrous material suitably coated for corrosion resistance, or any polymer and fixed to the front of the drawer or with a built in pulling mechanism) |
- |
0 |
|
- |
| 7.6.1(The drawer handle shall be strong enough to take
a minimum pull of 50 N for 2 min. There shall be no
sharp corners or edges to avoid injury and damage to clothing) |
- |
0 |
|
- |
| 7.7.1(Locks: Top drawer shall be provided with single or dual control key lock having not less than 6 levers or pin cylinder lock having not less than 6 pins, with duplicate keys of stainless steel/nonferrous alloy. Alternatively if required by the purchaser a 3 wheel combination lock or electronic combination lock may be provided either in place of key lock or in addition to key lock) |
- |
0 |
|
- |
| 7.7.2(Each drawer may also be provided with
individual key lock or pin cylinder lock or combination lock subject to agreement between the purchaser and the supplier.) |
- |
0 |
|
- |
| 7.8(Locking Mechanism ) |
- |
0 |
|
- |
| 7.8.1(The locking mechanism shall be such that when
the top drawer is pushed-in fully, it actuates locking
mechanism to lock all other drawers imultaneously,
when they are in pushed-in position) |
- |
0 |
|
- |
| 7.8.1.1(At the time of locking the cabinet, if one of the
drawers is not fully pushed-in, that drawer shall remain unlocked and can be used. As soon as that drawer is pushed-in fully, it shall get locked automatically without further operation of key by the user.) |
- |
0 |
|
- |
| 7.8.1.2(In addition to the above, isolation mechanism
shall also be provided to permit independent locking/ use of other drawers. Such isolation mechanism provided on drawers shall be manually operated) |
- |
0 |
|
- |
| 8(Assemblies) |
- |
0 |
|
- |
| 8.1(The components shall be assembled by bolting,
welding, riveting or by any combination of these
processes) |
- |
0 |
|
- |
| 8.2(All joints between outer body and inner boxes,
the drawer front and the outer body shall be such that, there is minimum direct conduction of heat from outer body to inner body) |
- |
0 |
|
- |
| 9.1(Drawer Suspension Test and Latch Test: The drawer loaded with evenly distributed load of 30 kg
(excluding the weight of drawer) in any drawer shall be operated for 5 000 cycles at a rate of 300 cycles/h ±10 percent. One opening and one closing shall constitute one cycle. The test shall be carried out with maximum two breaks by using electrically or mechanically operated test equipment with a counter fitted on it. After 5 000 cycles the suspension slide and latch mechanism shall not show any apparent distortion, cracks, or failures to operate in a normal smooth manner) |
- |
0 |
|
- |
| 10.1(Finish: All dents, burrs and sharp edges shall be removed from the various components and they shall be thoroughly degreased and cleaned of rust and scale) |
- |
0 |
|
- |
| 10.2(The inside and outside surfaces of the fire resisting
(Insulating) filing cabinet shall be painted or powder coated. In case of paint, an appropriate primer and undercoating shall be used in accordance to industry practices. The minimum overall thickness of the coatings shall be 50 μ for powder coating and 70 μ for liquid paint. Cross hatch test shall be conducted to confirm the adhesion of coating in accordance with 10.2.1) |
- |
0 |
|
- |
| 10.2.1(Cross Hatch Test) |
- |
0 |
|
- |
| 10.2.1(a) Make 6 parallel cut marks using sharp metal
pointer and straight edge, through the painted/
coated surface, so as to make the base surface
visible through cut marks) |
- |
0 |
|
- |
| 10.2.1(b) Cut marks shall be minimum 20 mm long and
at 2 mm distance from each other) |
- |
0 |
|
- |
| 10.2.1(c) Make 6 similar cut marks in the direction
perpendicular to first set of cut marks, with
same length and spacing) |
- |
0 |
|
- |
| 10.2.1(d) These 12 cut marks together shall make a
pattern of 25 squares of 2 mm × 2mm size,
totally separated from each other) |
- |
0 |
|
- |
| 10.2.1(g)Within 60 to 120 s after sticking the tape,
remove it by seizing free end of the tape and
rapidly pulling it off at an angle close to 180°.) |
- |
0 |
|
- |
| 10.2.1(h) Painting/Coating quality is considered as
acceptable, if no part of any 2 mm × 2 mm
square of paint/coat comes off the surface due
to pulling the tape) |
- |
0 |
|
- |
| 11.1(Fire endurance test) |
- |
0 |
|
- |
| 11.2(Fire and impact test) |
- |
0 |
|
- |
| 12.1(Marking of Cabinets:A metal plate showing classification of cabinet together with the manufacturer’s name, serial number and the
year of manufacture shall be fixed inside surface of
the top drawer of the cabinet in such a way that it is
visible when it is opened.) |
- |
0 |
|
- |
| 12.2(Marking on Keys: The keys shall bear an identification number which shall not be the same as the serial number of the cabinet) |
- |
0 |
|
- |
| 10.2.1(f) To ensure continuous contact with paint/coat
film, rub the tape firmly and remove air
bubbles under the tape, if any) |
- |
0 |
|
- |
|
08 Feb, 2027 |
- Included w.e.f. 01.04.2025 |
| 7094 |
Ace Test Labs & Metrology Pvt. Ltd., Sonipat
| 9162826
| IS 14561 (2014) |
Fire resisting (Insulating) filing cabinets - Specification (Second Revision) |
- |
258000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 3(Types & Rating) |
- |
5000 |
|
- |
| 3.1(i) The fire resisting filing cabinets shall be of two types:
a) Vertical fire resisting filing cabinet, and
b) Lateral fire resisting filing cabinet.) |
- |
5000 |
|
- |
| 3.2(ii) The standard and lateral fire resisting filing
cabinets shall have one-drawer or two-drawers or three drawers or four-drawers. A typical drawing of the fire resisting filing cabinet is given in Fig. 1.) |
- |
5000 |
|
- |
| 3.3(iii) The fire resisting filing cabinets shall have fire
resisting ratings of 60 min or 120 min or 180 min or
240 min) |
- |
5000 |
|
- |
| 4(Dimensions and Tolerances, mm) |
- |
5000 |
|
- |
| 4.1(Overall Dimensions of Fire Resisting Filing
Cabinets: The internal usable space of the drawers of fire resisting (insulating) filing cabinets shall be as specified in Table 1 or any other size which is mutually agreed to between the purchaser and the supplier.) |
- |
5000 |
|
- |
| 4.1(Internal usuable space of drawer, mm:) |
- |
5000 |
|
- |
| 4.1(i) Height) |
- |
5000 |
|
- |
| 4.1(ii) Width) |
- |
5000 |
|
- |
| 4.1(iii) Depth) |
- |
5000 |
|
- |
| 4.1(iv) Height of the bottom drawer above floor level) |
- |
5000 |
|
- |
| 5(Materials) |
- |
5000 |
|
- |
| 6(Designations: The filing cabinet shall be designated by the commonly used name, type, the fire rating and the number of this Indian Standard.) |
- |
5000 |
|
- |
| 7(Constructions) |
- |
15000 |
|
- |
| 7.1(Outer body and Inner Box: Outer body and inner box shall be fabricated from mild steel or galvanized steel sheets of not less than 0.8 mm and not more than 1.2 mm nominal thickness. The steel shall not have any burrs or dents. If required the outer
body shall be suitably stiffened to avoid bulging) |
- |
5000 |
|
- |
| 7.2(Cabinets Sub-Assembly: The external body and drawer fronts of the fire resisting (insulating) filing cabinet shall be of double wall type with homogeneous insulating material filled in
between. Further the construction of the cabinet shall be such that each drawer slides in an individual inner box. The inner boxes shall have a insulating layer between each other to prevent fire spreading from one drawer to another. The joining of inner box, intermediate piece and outer body shall be such that, it forms a cavity to receive drawer front ) |
- |
5000 |
|
- |
| 7.3(Filing Drawer: The drawer shall be made from mild steel or galvanized steel sheet of not less than 0.6 mm and not more than 1.0 mm nominal thickness and shall have an arrangement on the sides suitable for the drawer suspension system and an arrangement to stop it when fully pushed in.) |
- |
5000 |
|
- |
| 7.3.1(Drawer Front: The drawer front shall be made from mild steel or galvanized steel sheet of not less than 0.6 mm and not more than 1.0 mm nominal thickness and shall be firmly secured to the drawer body by welding, screwing or riveting or any combination of these processes. The construction of drawer front shall be such that it snugly fits in the cavity provided for the same ) |
- |
5000 |
|
- |
| 7.4.1(Latch: Each drawer of the cabinet shall be removable but shall be fitted with a latch/positive stop to prevent inadvertent withdrawal and rebound. Such latch shall be lifted/unlocked by the pull of the handle or any other mechanism.) |
- |
5000 |
|
- |
| 7.4.2(The locking mechanism shall be designed in such
a manner so that there is minimum passage for direct
conduction of heat from outside to inside) |
- |
5000 |
|
- |
| 7.5(Drawer Suspension The drawer suspension shall be either of the following types to ensure withdrawal of the full depth of the drawer:
a) Ball bearing / Roller bearing suspension
(Movement),
b) Solid roller suspension, and
c) Telescopic slide suspension (Extension) |
- |
5000 |
|
- |
| 7.6(Handles: Each drawer shall be provided either with a handle made from ferrous/non-ferrous material suitably coated for corrosion resistance, or any polymer and fixed to the front of the drawer or with a built in pulling mechanism) |
- |
5000 |
|
- |
| 7.6.1(The drawer handle shall be strong enough to take
a minimum pull of 50 N for 2 min. There shall be no
sharp corners or edges to avoid injury and damage to clothing) |
- |
5000 |
|
- |
| 7.7.1(Locks: Top drawer shall be provided with single or dual control key lock having not less than 6 levers or pin cylinder lock having not less than 6 pins, with duplicate keys of stainless steel/nonferrous alloy. Alternatively if required by the purchaser a 3 wheel combination lock or electronic combination lock may be provided either in place of key lock or in addition to key lock) |
- |
5000 |
|
- |
| 7.7.2(Each drawer may also be provided with
individual key lock or pin cylinder lock or combination lock subject to agreement between the purchaser and the supplier.) |
- |
5000 |
|
- |
| 7.8(Locking Mechanism ) |
- |
5000 |
|
- |
| 7.8.1(The locking mechanism shall be such that when
the top drawer is pushed-in fully, it actuates locking
mechanism to lock all other drawers imultaneously,
when they are in pushed-in position) |
- |
5000 |
|
- |
| 7.8.1.1(At the time of locking the cabinet, if one of the
drawers is not fully pushed-in, that drawer shall remain unlocked and can be used. As soon as that drawer is pushed-in fully, it shall get locked automatically without further operation of key by the user.) |
- |
5000 |
|
- |
| 7.8.1.2(In addition to the above, isolation mechanism
shall also be provided to permit independent locking/ use of other drawers. Such isolation mechanism provided on drawers shall be manually operated) |
- |
5000 |
|
- |
| 8(Assemblies) |
- |
5000 |
|
- |
| 8.1(The components shall be assembled by bolting,
welding, riveting or by any combination of these
processes) |
- |
5000 |
|
- |
| 8.2(All joints between outer body and inner boxes,
the drawer front and the outer body shall be such that, there is minimum direct conduction of heat from outer body to inner body) |
- |
5000 |
|
- |
| 9.1(Drawer Suspension Test and Latch Test: The drawer loaded with evenly distributed load of 30 kg
(excluding the weight of drawer) in any drawer shall be operated for 5 000 cycles at a rate of 300 cycles/h ±10 percent. One opening and one closing shall constitute one cycle. The test shall be carried out with maximum two breaks by using electrically or mechanically operated test equipment with a counter fitted on it. After 5 000 cycles the suspension slide and latch mechanism shall not show any apparent distortion, cracks, or failures to operate in a normal smooth manner) |
- |
5000 |
|
- |
| 10.1(Finish: All dents, burrs and sharp edges shall be removed from the various components and they shall be thoroughly degreased and cleaned of rust and scale) |
- |
5000 |
|
- |
| 10.2(The inside and outside surfaces of the fire resisting
(Insulating) filing cabinet shall be painted or powder coated. In case of paint, an appropriate primer and undercoating shall be used in accordance to industry practices. The minimum overall thickness of the coatings shall be 50 μ for powder coating and 70 μ for liquid paint. Cross hatch test shall be conducted to confirm the adhesion of coating in accordance with 10.2.1) |
- |
5000 |
|
- |
| 10.2.1(Cross Hatch Test) |
- |
5000 |
|
- |
| 10.2.1(a) Make 6 parallel cut marks using sharp metal
pointer and straight edge, through the painted/
coated surface, so as to make the base surface
visible through cut marks) |
- |
5000 |
|
- |
| 10.2.1(b) Cut marks shall be minimum 20 mm long and
at 2 mm distance from each other) |
- |
5000 |
|
- |
| 10.2.1(c) Make 6 similar cut marks in the direction
perpendicular to first set of cut marks, with
same length and spacing) |
- |
5000 |
|
- |
| 10.2.1(d) These 12 cut marks together shall make a
pattern of 25 squares of 2 mm × 2mm size,
totally separated from each other) |
- |
5000 |
|
- |
| 10.2.1(f) To ensure continuous contact with paint/coat
film, rub the tape firmly and remove air
bubbles under the tape, if any) |
- |
5000 |
|
- |
| 10.2.1(g)Within 60 to 120 s after sticking the tape,
remove it by seizing free end of the tape and
rapidly pulling it off at an angle close to 180°.) |
- |
5000 |
|
- |
| 10.2.1(h) Painting/Coating quality is considered as
acceptable, if no part of any 2 mm × 2 mm
square of paint/coat comes off the surface due
to pulling the tape) |
- |
5000 |
|
- |
| 11.1(Fire endurance test) |
- |
5000 |
|
- |
| 11.2(Fire and impact test) |
- |
5000 |
|
- |
| 12.1(Marking of Cabinets:A metal plate showing classification of cabinet together with the manufacturer’s name, serial number and the
year of manufacture shall be fixed inside surface of
the top drawer of the cabinet in such a way that it is
visible when it is opened.) |
- |
5000 |
|
- |
| 12.2(Marking on Keys: The keys shall bear an identification number which shall not be the same as the serial number of the cabinet) |
- |
5000 |
|
- |
| 3(Types & Rating) |
- |
5000 |
|
- |
| 3.1(i) The fire resisting filing cabinets shall be of two types:
a) Vertical fire resisting filing cabinet, and
b) Lateral fire resisting filing cabinet.) |
- |
5000 |
|
- |
| 3.2(ii) The standard and lateral fire resisting filing
cabinets shall have one-drawer or two-drawers or three drawers or four-drawers. A typical drawing of the fire resisting filing cabinet is given in Fig. 1.) |
- |
5000 |
|
- |
| 3.3(iii) The fire resisting filing cabinets shall have fire
resisting ratings of 60 min or 120 min or 180 min or
240 min) |
- |
5000 |
|
- |
| 4(Dimensions and Tolerances, mm) |
- |
5000 |
|
- |
| 4.1(Overall Dimensions of Fire Resisting Filing
Cabinets: The internal usable space of the drawers of fire resisting (insulating) filing cabinets shall be as specified in Table 1 or any other size which is mutually agreed to between the purchaser and the supplier.) |
- |
5000 |
|
- |
| 4.1(Internal usuable space of drawer, mm:) |
- |
5000 |
|
- |
| 4.1(i) Height) |
- |
5000 |
|
- |
| 4.1(ii) Width) |
- |
5000 |
|
- |
| 4.1(iii) Depth) |
- |
5000 |
|
- |
| 4.1(iv) Height of the bottom drawer above floor level) |
- |
5000 |
|
- |
| 5(Materials) |
- |
5000 |
|
- |
| 6(Designations: The filing cabinet shall be designated by the commonly used name, type, the fire rating and the number of this Indian Standard.) |
- |
5000 |
|
- |
| 7(Constructions) |
- |
5000 |
|
- |
| 7.1(Outer body and Inner Box: Outer body and inner box shall be fabricated from mild steel or galvanized steel sheets of not less than 0.8 mm and not more than 1.2 mm nominal thickness. The steel shall not have any burrs or dents. If required the outer
body shall be suitably stiffened to avoid bulging) |
- |
5000 |
|
- |
| 7.2(Cabinets Sub-Assembly: The external body and drawer fronts of the fire resisting (insulating) filing cabinet shall be of double wall type with homogeneous insulating material filled in
between. Further the construction of the cabinet shall be such that each drawer slides in an individual inner box. The inner boxes shall have a insulating layer between each other to prevent fire spreading from one drawer to another. The joining of inner box, intermediate piece and outer body shall be such that, it forms a cavity to receive drawer front ) |
- |
5000 |
|
- |
| 7.3(Filing Drawer: The drawer shall be made from mild steel or galvanized steel sheet of not less than 0.6 mm and not more than 1.0 mm nominal thickness and shall have an arrangement on the sides suitable for the drawer suspension system and an arrangement to stop it when fully pushed in.) |
- |
5000 |
|
- |
| 7.3.1(Drawer Front: The drawer front shall be made from mild steel or galvanized steel sheet of not less than 0.6 mm and not more than 1.0 mm nominal thickness and shall be firmly secured to the drawer body by welding, screwing or riveting or any combination of these processes. The construction of drawer front shall be such that it snugly fits in the cavity provided for the same ) |
- |
5000 |
|
- |
| 7.4.1(Latch: Each drawer of the cabinet shall be removable but shall be fitted with a latch/positive stop to prevent inadvertent withdrawal and rebound. Such latch shall be lifted/unlocked by the pull of the handle or any other mechanism.) |
- |
5000 |
|
- |
| 7.4.2(The locking mechanism shall be designed in such
a manner so that there is minimum passage for direct
conduction of heat from outside to inside) |
- |
5000 |
|
- |
| 7.5(Drawer Suspension The drawer suspension shall be either of the following types to ensure withdrawal of the full depth of the drawer:
a) Ball bearing / Roller bearing suspension
(Movement),
b) Solid roller suspension, and
c) Telescopic slide suspension (Extension) |
- |
5000 |
|
- |
| 7.6(Handles: Each drawer shall be provided either with a handle made from ferrous/non-ferrous material suitably coated for corrosion resistance, or any polymer and fixed to the front of the drawer or with a built in pulling mechanism) |
- |
5000 |
|
- |
| 7.6.1(The drawer handle shall be strong enough to take
a minimum pull of 50 N for 2 min. There shall be no
sharp corners or edges to avoid injury and damage to clothing) |
- |
5000 |
|
- |
| 7.7.1(Locks: Top drawer shall be provided with single or dual control key lock having not less than 6 levers or pin cylinder lock having not less than 6 pins, with duplicate keys of stainless steel/nonferrous alloy. Alternatively if required by the purchaser a 3 wheel combination lock or electronic combination lock may be provided either in place of key lock or in addition to key lock) |
- |
5000 |
|
- |
| 7.7.2(Each drawer may also be provided with
individual key lock or pin cylinder lock or combination lock subject to agreement between the purchaser and the supplier.) |
- |
5000 |
|
- |
| 7.8(Locking Mechanism ) |
- |
5000 |
|
- |
| 7.8.1(The locking mechanism shall be such that when
the top drawer is pushed-in fully, it actuates locking
mechanism to lock all other drawers imultaneously,
when they are in pushed-in position) |
- |
5000 |
|
- |
| 7.8.1.1(At the time of locking the cabinet, if one of the
drawers is not fully pushed-in, that drawer shall remain unlocked and can be used. As soon as that drawer is pushed-in fully, it shall get locked automatically without further operation of key by the user.) |
- |
5000 |
|
- |
| 7.8.1.2(In addition to the above, isolation mechanism
shall also be provided to permit independent locking/ use of other drawers. Such isolation mechanism provided on drawers shall be manually operated) |
- |
5000 |
|
- |
| 8(Assemblies) |
- |
5000 |
|
- |
| 8.1(The components shall be assembled by bolting,
welding, riveting or by any combination of these
processes) |
- |
5000 |
|
- |
| 8.2(All joints between outer body and inner boxes,
the drawer front and the outer body shall be such that, there is minimum direct conduction of heat from outer body to inner body) |
- |
5000 |
|
- |
| 9.1(Drawer Suspension Test and Latch Test: The drawer loaded with evenly distributed load of 30 kg
(excluding the weight of drawer) in any drawer shall be operated for 5 000 cycles at a rate of 300 cycles/h ±10 percent. One opening and one closing shall constitute one cycle. The test shall be carried out with maximum two breaks by using electrically or mechanically operated test equipment with a counter fitted on it. After 5 000 cycles the suspension slide and latch mechanism shall not show any apparent distortion, cracks, or failures to operate in a normal smooth manner) |
- |
5000 |
|
- |
| 10.1(Finish: All dents, burrs and sharp edges shall be removed from the various components and they shall be thoroughly degreased and cleaned of rust and scale) |
- |
5000 |
|
- |
| 10.2(The inside and outside surfaces of the fire resisting
(Insulating) filing cabinet shall be painted or powder coated. In case of paint, an appropriate primer and undercoating shall be used in accordance to industry practices. The minimum overall thickness of the coatings shall be 50 μ for powder coating and 70 μ for liquid paint. Cross hatch test shall be conducted to confirm the adhesion of coating in accordance with 10.2.1) |
- |
5000 |
|
- |
| 10.2.1(Cross Hatch Test) |
- |
5000 |
|
- |
| 10.2.1(a) Make 6 parallel cut marks using sharp metal
pointer and straight edge, through the painted/
coated surface, so as to make the base surface
visible through cut marks) |
- |
5000 |
|
- |
| 10.2.1(b) Cut marks shall be minimum 20 mm long and
at 2 mm distance from each other) |
- |
5000 |
|
- |
| 10.2.1(c) Make 6 similar cut marks in the direction
perpendicular to first set of cut marks, with
same length and spacing) |
- |
5000 |
|
- |
| 10.2.1(d) These 12 cut marks together shall make a
pattern of 25 squares of 2 mm × 2mm size,
totally separated from each other) |
- |
5000 |
|
- |
| 10.2.1(f) To ensure continuous contact with paint/coat
film, rub the tape firmly and remove air
bubbles under the tape, if any) |
- |
5000 |
|
- |
| 10.2.1(g)Within 60 to 120 s after sticking the tape,
remove it by seizing free end of the tape and
rapidly pulling it off at an angle close to 180°.) |
- |
5000 |
|
- |
| 10.2.1(h) Painting/Coating quality is considered as
acceptable, if no part of any 2 mm × 2 mm
square of paint/coat comes off the surface due
to pulling the tape) |
- |
5000 |
|
- |
| 11.1(Fire endurance test) |
- |
150000 |
|
- |
| 11.2(Fire and impact test) |
- |
150000 |
|
- |
| 12.1(Marking of Cabinets:A metal plate showing classification of cabinet together with the manufacturer’s name, serial number and the
year of manufacture shall be fixed inside surface of
the top drawer of the cabinet in such a way that it is
visible when it is opened.) |
- |
15000 |
|
- |
| 12.2(Marking on Keys: The keys shall bear an identification number which shall not be the same as the serial number of the cabinet) |
- |
15000 |
|
- |
| 3(Types & Rating) |
- |
15000 |
|
- |
| 3.1(i) The fire resisting filing cabinets shall be of two types:
a) Vertical fire resisting filing cabinet, and
b) Lateral fire resisting filing cabinet.) |
- |
15000 |
|
- |
| 3.2(ii) The standard and lateral fire resisting filing
cabinets shall have one-drawer or two-drawers or three drawers or four-drawers. A typical drawing of the fire resisting filing cabinet is given in Fig. 1.) |
- |
15000 |
|
- |
| 3.3(iii) The fire resisting filing cabinets shall have fire
resisting ratings of 60 min or 120 min or 180 min or
240 min) |
- |
15000 |
|
- |
| 4(Dimensions and Tolerances, mm) |
- |
15000 |
|
- |
| 4.1(Overall Dimensions of Fire Resisting Filing
Cabinets: The internal usable space of the drawers of fire resisting (insulating) filing cabinets shall be as specified in Table 1 or any other size which is mutually agreed to between the purchaser and the supplier.) |
- |
15000 |
|
- |
| 4.1(Internal usuable space of drawer, mm:) |
- |
15000 |
|
- |
| 4.1(i) Height) |
- |
15000 |
|
- |
| 4.1(ii) Width) |
- |
15000 |
|
- |
| 4.1(iii) Depth) |
- |
15000 |
|
- |
| 4.1(iv) Height of the bottom drawer above floor level) |
- |
15000 |
|
- |
| 5(Materials) |
- |
15000 |
|
- |
| 6(Designations: The filing cabinet shall be designated by the commonly used name, type, the fire rating and the number of this Indian Standard.) |
- |
15000 |
|
- |
| 7(Constructions) |
- |
15000 |
|
- |
| 7.1(Outer body and Inner Box: Outer body and inner box shall be fabricated from mild steel or galvanized steel sheets of not less than 0.8 mm and not more than 1.2 mm nominal thickness. The steel shall not have any burrs or dents. If required the outer
body shall be suitably stiffened to avoid bulging) |
- |
15000 |
|
- |
| 7.2(Cabinets Sub-Assembly: The external body and drawer fronts of the fire resisting (insulating) filing cabinet shall be of double wall type with homogeneous insulating material filled in
between. Further the construction of the cabinet shall be such that each drawer slides in an individual inner box. The inner boxes shall have a insulating layer between each other to prevent fire spreading from one drawer to another. The joining of inner box, intermediate piece and outer body shall be such that, it forms a cavity to receive drawer front ) |
- |
15000 |
|
- |
| 7.3(Filing Drawer: The drawer shall be made from mild steel or galvanized steel sheet of not less than 0.6 mm and not more than 1.0 mm nominal thickness and shall have an arrangement on the sides suitable for the drawer suspension system and an arrangement to stop it when fully pushed in.) |
- |
15000 |
|
- |
| 7.3.1(Drawer Front: The drawer front shall be made from mild steel or galvanized steel sheet of not less than 0.6 mm and not more than 1.0 mm nominal thickness and shall be firmly secured to the drawer body by welding, screwing or riveting or any combination of these processes. The construction of drawer front shall be such that it snugly fits in the cavity provided for the same ) |
- |
15000 |
|
- |
| 7.4.1(Latch: Each drawer of the cabinet shall be removable but shall be fitted with a latch/positive stop to prevent inadvertent withdrawal and rebound. Such latch shall be lifted/unlocked by the pull of the handle or any other mechanism.) |
- |
15000 |
|
- |
| 7.4.2(The locking mechanism shall be designed in such
a manner so that there is minimum passage for direct
conduction of heat from outside to inside) |
- |
15000 |
|
- |
| 7.5(Drawer Suspension The drawer suspension shall be either of the following types to ensure withdrawal of the full depth of the drawer:
a) Ball bearing / Roller bearing suspension
(Movement),
b) Solid roller suspension, and
c) Telescopic slide suspension (Extension) |
- |
15000 |
|
- |
| 7.6(Handles: Each drawer shall be provided either with a handle made from ferrous/non-ferrous material suitably coated for corrosion resistance, or any polymer and fixed to the front of the drawer or with a built in pulling mechanism) |
- |
15000 |
|
- |
| 7.6.1(The drawer handle shall be strong enough to take
a minimum pull of 50 N for 2 min. There shall be no
sharp corners or edges to avoid injury and damage to clothing) |
- |
15000 |
|
- |
| 7.7.1(Locks: Top drawer shall be provided with single or dual control key lock having not less than 6 levers or pin cylinder lock having not less than 6 pins, with duplicate keys of stainless steel/nonferrous alloy. Alternatively if required by the purchaser a 3 wheel combination lock or electronic combination lock may be provided either in place of key lock or in addition to key lock) |
- |
15000 |
|
- |
| 7.7.2(Each drawer may also be provided with
individual key lock or pin cylinder lock or combination lock subject to agreement between the purchaser and the supplier.) |
- |
15000 |
|
- |
| 7.8(Locking Mechanism ) |
- |
15000 |
|
- |
| 7.8.1(The locking mechanism shall be such that when
the top drawer is pushed-in fully, it actuates locking
mechanism to lock all other drawers imultaneously,
when they are in pushed-in position) |
- |
15000 |
|
- |
| 7.8.1.1(At the time of locking the cabinet, if one of the
drawers is not fully pushed-in, that drawer shall remain unlocked and can be used. As soon as that drawer is pushed-in fully, it shall get locked automatically without further operation of key by the user.) |
- |
15000 |
|
- |
| 7.8.1.2(In addition to the above, isolation mechanism
shall also be provided to permit independent locking/ use of other drawers. Such isolation mechanism provided on drawers shall be manually operated) |
- |
15000 |
|
- |
| 8(Assemblies) |
- |
15000 |
|
- |
| 8.1(The components shall be assembled by bolting,
welding, riveting or by any combination of these
processes) |
- |
15000 |
|
- |
| 8.2(All joints between outer body and inner boxes,
the drawer front and the outer body shall be such that, there is minimum direct conduction of heat from outer body to inner body) |
- |
15000 |
|
- |
| 9.1(Drawer Suspension Test and Latch Test: The drawer loaded with evenly distributed load of 30 kg
(excluding the weight of drawer) in any drawer shall be operated for 5 000 cycles at a rate of 300 cycles/h ±10 percent. One opening and one closing shall constitute one cycle. The test shall be carried out with maximum two breaks by using electrically or mechanically operated test equipment with a counter fitted on it. After 5 000 cycles the suspension slide and latch mechanism shall not show any apparent distortion, cracks, or failures to operate in a normal smooth manner) |
- |
15000 |
|
- |
| 10.1(Finish: All dents, burrs and sharp edges shall be removed from the various components and they shall be thoroughly degreased and cleaned of rust and scale) |
- |
15000 |
|
- |
| 10.2(The inside and outside surfaces of the fire resisting
(Insulating) filing cabinet shall be painted or powder coated. In case of paint, an appropriate primer and undercoating shall be used in accordance to industry practices. The minimum overall thickness of the coatings shall be 50 μ for powder coating and 70 μ for liquid paint. Cross hatch test shall be conducted to confirm the adhesion of coating in accordance with 10.2.1) |
- |
15000 |
|
- |
| 10.2.1(Cross Hatch Test) |
- |
15000 |
|
- |
| 10.2.1(a) Make 6 parallel cut marks using sharp metal
pointer and straight edge, through the painted/
coated surface, so as to make the base surface
visible through cut marks) |
- |
15000 |
|
- |
| 10.2.1(b) Cut marks shall be minimum 20 mm long and
at 2 mm distance from each other) |
- |
15000 |
|
- |
| 10.2.1(c) Make 6 similar cut marks in the direction
perpendicular to first set of cut marks, with
same length and spacing) |
- |
15000 |
|
- |
| 10.2.1(d) These 12 cut marks together shall make a
pattern of 25 squares of 2 mm × 2mm size,
totally separated from each other) |
- |
15000 |
|
- |
| 10.2.1(f) To ensure continuous contact with paint/coat
film, rub the tape firmly and remove air
bubbles under the tape, if any) |
- |
15000 |
|
- |
| 10.2.1(g)Within 60 to 120 s after sticking the tape,
remove it by seizing free end of the tape and
rapidly pulling it off at an angle close to 180°.) |
- |
15000 |
|
- |
| 10.2.1(h) Painting/Coating quality is considered as
acceptable, if no part of any 2 mm × 2 mm
square of paint/coat comes off the surface due
to pulling the tape) |
- |
15000 |
|
- |
| 11.1(Fire endurance test) |
- |
15000 |
|
- |
| 11.2(Fire and impact test) |
- |
15000 |
|
- |
| 12.1(Marking of Cabinets:A metal plate showing classification of cabinet together with the manufacturer’s name, serial number and the
year of manufacture shall be fixed inside surface of
the top drawer of the cabinet in such a way that it is
visible when it is opened.) |
- |
15000 |
|
- |
| 12.2(Marking on Keys: The keys shall bear an identification number which shall not be the same as the serial number of the cabinet) |
- |
15000 |
|
- |
| 3(Types & Rating) |
- |
15000 |
|
- |
| 3.1(i) The fire resisting filing cabinets shall be of two types:
a) Vertical fire resisting filing cabinet, and
b) Lateral fire resisting filing cabinet.) |
- |
15000 |
|
- |
| 3.2(ii) The standard and lateral fire resisting filing
cabinets shall have one-drawer or two-drawers or three drawers or four-drawers. A typical drawing of the fire resisting filing cabinet is given in Fig. 1.) |
- |
15000 |
|
- |
| 3.3(iii) The fire resisting filing cabinets shall have fire
resisting ratings of 60 min or 120 min or 180 min or
240 min) |
- |
15000 |
|
- |
| 4(Dimensions and Tolerances, mm) |
- |
15000 |
|
- |
| 4.1(Overall Dimensions of Fire Resisting Filing
Cabinets: The internal usable space of the drawers of fire resisting (insulating) filing cabinets shall be as specified in Table 1 or any other size which is mutually agreed to between the purchaser and the supplier.) |
- |
15000 |
|
- |
| 4.1(Internal usuable space of drawer, mm:) |
- |
15000 |
|
- |
| 4.1(i) Height) |
- |
15000 |
|
- |
| 4.1(ii) Width) |
- |
15000 |
|
- |
| 4.1(iii) Depth) |
- |
15000 |
|
- |
| 4.1(iv) Height of the bottom drawer above floor level) |
- |
15000 |
|
- |
| 5(Materials) |
- |
15000 |
|
- |
| 6(Designations: The filing cabinet shall be designated by the commonly used name, type, the fire rating and the number of this Indian Standard.) |
- |
15000 |
|
- |
| 7(Constructions) |
- |
15000 |
|
- |
| 7.1(Outer body and Inner Box: Outer body and inner box shall be fabricated from mild steel or galvanized steel sheets of not less than 0.8 mm and not more than 1.2 mm nominal thickness. The steel shall not have any burrs or dents. If required the outer
body shall be suitably stiffened to avoid bulging) |
- |
15000 |
|
- |
| 7.2(Cabinets Sub-Assembly: The external body and drawer fronts of the fire resisting (insulating) filing cabinet shall be of double wall type with homogeneous insulating material filled in
between. Further the construction of the cabinet shall be such that each drawer slides in an individual inner box. The inner boxes shall have a insulating layer between each other to prevent fire spreading from one drawer to another. The joining of inner box, intermediate piece and outer body shall be such that, it forms a cavity to receive drawer front ) |
- |
15000 |
|
- |
| 7.3(Filing Drawer: The drawer shall be made from mild steel or galvanized steel sheet of not less than 0.6 mm and not more than 1.0 mm nominal thickness and shall have an arrangement on the sides suitable for the drawer suspension system and an arrangement to stop it when fully pushed in.) |
- |
15000 |
|
- |
| 7.3.1(Drawer Front: The drawer front shall be made from mild steel or galvanized steel sheet of not less than 0.6 mm and not more than 1.0 mm nominal thickness and shall be firmly secured to the drawer body by welding, screwing or riveting or any combination of these processes. The construction of drawer front shall be such that it snugly fits in the cavity provided for the same ) |
- |
15000 |
|
- |
| 7.4.1(Latch: Each drawer of the cabinet shall be removable but shall be fitted with a latch/positive stop to prevent inadvertent withdrawal and rebound. Such latch shall be lifted/unlocked by the pull of the handle or any other mechanism.) |
- |
15000 |
|
- |
| 7.4.2(The locking mechanism shall be designed in such
a manner so that there is minimum passage for direct
conduction of heat from outside to inside) |
- |
15000 |
|
- |
| 7.5(Drawer Suspension The drawer suspension shall be either of the following types to ensure withdrawal of the full depth of the drawer:
a) Ball bearing / Roller bearing suspension
(Movement),
b) Solid roller suspension, and
c) Telescopic slide suspension (Extension) |
- |
15000 |
|
- |
| 7.6(Handles: Each drawer shall be provided either with a handle made from ferrous/non-ferrous material suitably coated for corrosion resistance, or any polymer and fixed to the front of the drawer or with a built in pulling mechanism) |
- |
15000 |
|
- |
| 7.6.1(The drawer handle shall be strong enough to take
a minimum pull of 50 N for 2 min. There shall be no
sharp corners or edges to avoid injury and damage to clothing) |
- |
15000 |
|
- |
| 7.7.1(Locks: Top drawer shall be provided with single or dual control key lock having not less than 6 levers or pin cylinder lock having not less than 6 pins, with duplicate keys of stainless steel/nonferrous alloy. Alternatively if required by the purchaser a 3 wheel combination lock or electronic combination lock may be provided either in place of key lock or in addition to key lock) |
- |
15000 |
|
- |
| 7.7.2(Each drawer may also be provided with
individual key lock or pin cylinder lock or combination lock subject to agreement between the purchaser and the supplier.) |
- |
15000 |
|
- |
| 7.8(Locking Mechanism ) |
- |
15000 |
|
- |
| 7.8.1(The locking mechanism shall be such that when
the top drawer is pushed-in fully, it actuates locking
mechanism to lock all other drawers imultaneously,
when they are in pushed-in position) |
- |
15000 |
|
- |
| 7.8.1.1(At the time of locking the cabinet, if one of the
drawers is not fully pushed-in, that drawer shall remain unlocked and can be used. As soon as that drawer is pushed-in fully, it shall get locked automatically without further operation of key by the user.) |
- |
15000 |
|
- |
| 7.8.1.2(In addition to the above, isolation mechanism
shall also be provided to permit independent locking/ use of other drawers. Such isolation mechanism provided on drawers shall be manually operated) |
- |
15000 |
|
- |
| 8(Assemblies) |
- |
15000 |
|
- |
| 8.1(The components shall be assembled by bolting,
welding, riveting or by any combination of these
processes) |
- |
15000 |
|
- |
| 8.2(All joints between outer body and inner boxes,
the drawer front and the outer body shall be such that, there is minimum direct conduction of heat from outer body to inner body) |
- |
15000 |
|
- |
| 9.1(Drawer Suspension Test and Latch Test: The drawer loaded with evenly distributed load of 30 kg
(excluding the weight of drawer) in any drawer shall be operated for 5 000 cycles at a rate of 300 cycles/h ±10 percent. One opening and one closing shall constitute one cycle. The test shall be carried out with maximum two breaks by using electrically or mechanically operated test equipment with a counter fitted on it. After 5 000 cycles the suspension slide and latch mechanism shall not show any apparent distortion, cracks, or failures to operate in a normal smooth manner) |
- |
15000 |
|
- |
| 10.1(Finish: All dents, burrs and sharp edges shall be removed from the various components and they shall be thoroughly degreased and cleaned of rust and scale) |
- |
15000 |
|
- |
| 10.2(The inside and outside surfaces of the fire resisting
(Insulating) filing cabinet shall be painted or powder coated. In case of paint, an appropriate primer and undercoating shall be used in accordance to industry practices. The minimum overall thickness of the coatings shall be 50 μ for powder coating and 70 μ for liquid paint. Cross hatch test shall be conducted to confirm the adhesion of coating in accordance with 10.2.1) |
- |
15000 |
|
- |
| 10.2.1(Cross Hatch Test) |
- |
15000 |
|
- |
| 10.2.1(a) Make 6 parallel cut marks using sharp metal
pointer and straight edge, through the painted/
coated surface, so as to make the base surface
visible through cut marks) |
- |
15000 |
|
- |
| 10.2.1(b) Cut marks shall be minimum 20 mm long and
at 2 mm distance from each other) |
- |
15000 |
|
- |
| 10.2.1(c) Make 6 similar cut marks in the direction
perpendicular to first set of cut marks, with
same length and spacing) |
- |
15000 |
|
- |
| 10.2.1(d) These 12 cut marks together shall make a
pattern of 25 squares of 2 mm × 2mm size,
totally separated from each other) |
- |
15000 |
|
- |
| 10.2.1(f) To ensure continuous contact with paint/coat
film, rub the tape firmly and remove air
bubbles under the tape, if any) |
- |
15000 |
|
- |
| 10.2.1(g)Within 60 to 120 s after sticking the tape,
remove it by seizing free end of the tape and
rapidly pulling it off at an angle close to 180°.) |
- |
15000 |
|
- |
| 10.2.1(h) Painting/Coating quality is considered as
acceptable, if no part of any 2 mm × 2 mm
square of paint/coat comes off the surface due
to pulling the tape) |
- |
15000 |
|
- |
| 11.1(Fire endurance test) |
- |
150000 |
|
- |
| 11.2(Fire and impact test) |
- |
150000 |
|
- |
| 12.1(Marking of Cabinets:A metal plate showing classification of cabinet together with the manufacturer’s name, serial number and the
year of manufacture shall be fixed inside surface of
the top drawer of the cabinet in such a way that it is
visible when it is opened.) |
- |
5000 |
|
- |
| 12.2(Marking on Keys: The keys shall bear an identification number which shall not be the same as the serial number of the cabinet) |
- |
5000 |
|
- |
|
14 Nov, 2027 |
- Included w.e.f. 28.03.2025 |
| 7095 |
URS PRODUCTS AND TESTING PVT. LTD. (A29), NOIDA
| 8168906
| IS 21 (1992) |
Wrought aluminium and aluminium alloys for manufacture of utensils specification (Fourth Revision) |
- |
15000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4.1, & 4.1.1(Lead) |
- |
1500 |
|
- |
| 4.1.2(Aluminium) |
- |
800 |
|
- |
| 4.2,
Table 1of IS:21 (Designation 64430)(Aluminium) |
- |
800 |
|
- |
| 4.2,
Table 1of IS:21 (Designation 64430)(Lead) |
- |
800 |
|
- |
| 4.2,
Table 1of IS:21 (Designation 64430)(Chromium) |
- |
800 |
|
- |
| 4.2,
Table 1of IS:21 (Designation 64430)(Titanium and or other grain refining elements) |
- |
800 |
|
- |
| 4.2,
Table 1of IS:21 (Designation 64430)(Zinc) |
- |
800 |
|
- |
| 4.2,
Table 1of IS:21 (Designation 64430)(Manganese) |
- |
800 |
|
- |
| 4.2,
Table 1of IS:21 (Designation 64430)(Iron) |
- |
800 |
|
- |
| 4.2,
Table 1of IS:21 (Designation 40800)(Silicon) |
- |
800 |
|
- |
| 4.2,
Table 1of IS:21 (Designation 64430)(Magnesium) |
- |
800 |
|
- |
| 4.2,
Table 1of IS:21 (Designation 64430)(Copper) |
- |
800 |
|
- |
| 4.2,
Table 1of IS:21 (Designation 51000-B)(Aluminium) |
- |
800 |
|
- |
| 4.2,
Table 1of IS:21 (Designation 51000-B)(Lead) |
- |
800 |
|
- |
| 4.2,
Table 1of IS:21 (Designation 51000-B)(Chromium) |
- |
800 |
|
- |
| 4.2,
Table 1of IS:21 (Designation 51000-B)(Zinc) |
- |
800 |
|
- |
| 4.2,
Table 1of IS:21 (Designation 51000-B)(Manganese) |
- |
800 |
|
- |
| 4.2,
Table 1of IS:21 (Designation 51000-B)(Iron) |
- |
800 |
|
- |
| 4.2,
Table 1of IS:21 (Designation 51000-B)(Silicon) |
- |
800 |
|
- |
| 4.2,
Table 1of IS:21 (Designation 51000-B)(Magnesium) |
- |
800 |
|
- |
| 4.2,
Table 1of IS:21 (Designation 51000-B)(Copper) |
- |
800 |
|
- |
| 4.2,
Table 1of IS:21 (Designation 51000-A)(Aluminium) |
- |
800 |
|
- |
| 4.2,
Table 1of IS:21 (Designation 51000-A)(Lead) |
- |
800 |
|
- |
| 4.2,
Table 1of IS:21 (Designation 51000-A)(Chromium) |
- |
800 |
|
- |
| 4.2,
Table 1of IS:21 (Designation 51000-A)(Zinc) |
- |
800 |
|
- |
| 4.2,
Table 1of IS:21 (Designation 51000-A)(Manganese) |
- |
800 |
|
- |
| 4.2,
Table 1of IS:21 (Designation 51000-A)(Iron) |
- |
800 |
|
- |
| 4.2,
Table 1of IS:21 (Designation 51000-A)(Silicon) |
- |
800 |
|
- |
| 4.2,
Table 1of IS:21 (Designation 51000-A)(Magnesium) |
- |
800 |
|
- |
| 4.2,
Table 1of IS:21 (Designation 51000-A)(Copper) |
- |
800 |
|
- |
| 4.2,
Table 1of IS:21 (Designation 40800)(Aluminium) |
- |
800 |
|
- |
| 4.2,
Table 1of IS:21 (Designation 40800)(Lead) |
- |
800 |
|
- |
| 4.2,
Table 1of IS:21 (Designation 40800)(Titanium and or other grain refining elements) |
- |
800 |
|
- |
| 4.2,
Table 1of IS:21 (Designation 40800)(Zinc) |
- |
800 |
|
- |
| 4.2,
Table 1of IS:21 (Designation 40800)(Manganese) |
- |
800 |
|
- |
| 4.2,
Table 1of IS:21 (Designation 40800)(Iron) |
- |
800 |
|
- |
| 4.2,
Table 1of IS:21 (Designation 40800)(Magnesium) |
- |
800 |
|
- |
| 4.2,
Table 1of IS:21 (Designation 40800)(Copper) |
- |
800 |
|
- |
| 4.2,
Table 1of IS:21 (Designation 31500)(Aluminium) |
- |
800 |
|
- |
| 4.2,
Table 1of IS:21 (Designation 31500)(Titanium and or other grain refining elements) |
- |
800 |
|
- |
| 4.2,
Table 1of IS:21 (Designation 31500)(Lead) |
- |
800 |
|
- |
| 4.2,
Table 1of IS:21 (Designation 31500)(Zinc) |
- |
800 |
|
- |
| 4.2,
Table 1of IS:21 (Designation 31500)(Manganese) |
- |
800 |
|
- |
| 4.2,
Table 1of IS:21 (Designation 31500)(Iron) |
- |
800 |
|
- |
| 4.2,
Table 1of IS:21 (Designation 31500)(Silicon) |
- |
800 |
|
- |
| 4.2,
Table 1of IS:21 (Designation 31500)(Magnesium) |
- |
800 |
|
- |
| 4.2,
Table 1of IS:21 (Designation 31500)(Copper) |
- |
800 |
|
- |
| 4.2,
Table 1of IS:21 (Designation 31000)(Aluminium) |
- |
800 |
|
- |
| 4.2,
Table 1of IS:21 (Designation 31000)(Lead) |
- |
800 |
|
- |
| 4.2,
Table 1of IS:21 (Designation 31000)(Chromium) |
- |
800 |
|
- |
| 4.2,
Table 1of IS:21 (Designation 31000)(Titanium and or other grain refining elements) |
- |
800 |
|
- |
| 4.2,
Table 1of IS:21 (Designation 31000)(Zinc) |
- |
800 |
|
- |
| 4.2,
Table 1of IS:21 (Designation 31000)(Manganese) |
- |
800 |
|
- |
| 4.2,
Table 1of IS:21 (Designation 31000)(Iron) |
- |
800 |
|
- |
| 4.2,
Table 1of IS:21 (Designation 31000)(Silicon) |
- |
800 |
|
- |
| 4.2,
Table 1of IS:21 (Designation 31000)(Magnesium) |
- |
800 |
|
- |
| 4.2,
Table 1of IS:21 (Designation 31000)(Copper) |
- |
800 |
|
- |
| 4.2,
Table 1of IS:21 (Designation 19600)(Aluminium) |
- |
800 |
|
- |
| 4.2,
Table 1of IS:21 (Designation 19600)(Cu+Si+Fe+Mn+Zn) |
- |
800 |
|
- |
| 4.2,
Table 1of IS:21 (Designation 19500)(Aluminium) |
- |
800 |
|
- |
| 4.2,
Table 1of IS:21 (Designation 19500)(Cu+Si+Fe+Mn+Zn) |
- |
800 |
|
- |
| 4.2,
Table 1of IS:21 (Designation 19000)(Cu+Mg+Si+Fe+Mn+Zn) |
- |
800 |
|
- |
| 4.2,
Table 1of IS:21 (Designation 19000)(Aluminium) |
- |
800 |
|
- |
| 4.2,
Table 1of IS:21 (Designation 19600)(Lead) |
- |
800 |
|
- |
| 4.2,
Table 1of IS:21 (Designation 19500)(Lead) |
- |
800 |
|
- |
| 4.2,
Table 1of IS:21 (Designation 19000)(Lead) |
- |
800 |
|
- |
| 4.2,
Table 1of IS:21 (Designation 19600)(Zinc) |
- |
800 |
|
- |
| 4.2,
Table 1of IS:21 (Designation 19500)(Zinc) |
- |
800 |
|
- |
| 4.2,
Table 1of IS:21 (Designation 19000)(Zinc) |
- |
800 |
|
- |
| 4.2,
Table 1of IS:21 (Designation 19600)(Manganese) |
- |
800 |
|
- |
| 4.2,
Table 1of IS:21 (Designation 19500)(Manganese) |
- |
800 |
|
- |
| 4.2,
Table 1of IS:21 (Designation 19000)(Manganese) |
- |
800 |
|
- |
| 4.2,
Table 1of IS:21 (Designation 19600)(Iron) |
- |
800 |
|
- |
| 4.2,
Table 1of IS:21 (Designation 19500)(Iron) |
- |
800 |
|
- |
| 4.2,
Table 1of IS:21 (Designation 19000)(Iron) |
- |
800 |
|
- |
| 4.2,
Table 1of IS:21 (Designation 19600)(Silicon) |
- |
800 |
|
- |
| 4.2,
Table 1of IS:21 (Designation 19500)(Silicon) |
- |
800 |
|
- |
| 4.2,
Table 1of IS:21 (Designation 19000)(Silicon) |
- |
800 |
|
- |
| 4.2,
Table 1of IS:21 (Designation 19600)(Copper) |
- |
800 |
|
- |
| 4.2,
Table 1of IS:21 (Designation 19500)(Copper) |
- |
800 |
|
- |
| 4.2,
Table 1of IS:21 (Designation 19000)(Copper) |
- |
800 |
|
- |
| 4.2,
Table 1of IS:21 (Designation 19000)(Magnesium) |
- |
800 |
|
- |
| 4.2,
Table 2 of IS:21 (Designation & Condition 64430, WP')(Tensile Strength) |
- |
2000 |
|
- |
| 4.2,
Table 2 of IS:21 (Designation & Condition 64430, 'W')(Tensile Strength) |
- |
2000 |
|
- |
| 4.2,
Table 2 of IS:21 (Designation & Condition 64430, 'O')(Tensile Strength) |
- |
2000 |
|
- |
| 4.2,
Table 2 of IS:21 (Designation & Condition 51000-B, 'H4')(Tensile Strength) |
- |
2000 |
|
- |
| 4.2,
Table 2 of IS:21 (Designation & Condition 51000-B, 'H3')(Tensile Strength) |
- |
2000 |
|
- |
| 4.2,
Table 2 of IS:21 (Designation & Condition 51000-B, 'H2')(Tensile Strength) |
- |
2000 |
|
- |
| 4.2,
Table 2 of IS:21 (Designation & Condition 51000-B, 'H1')(Tensile Strength) |
- |
2000 |
|
- |
| 4.2,
Table 2 of IS:21 (Designation & Condition 51000-A, 'H3')(Tensile Strength) |
- |
2000 |
|
- |
| 4.2,
Table 2 of IS:21 (Designation & Condition 51000-A, 'H2')(Tensile Strength) |
- |
2000 |
|
- |
| 4.2,
Table 2 of IS:21 (Designation & Condition 51000-A, 'H1')(Tensile Strength) |
- |
2000 |
|
- |
| 4.2,
Table 2 of IS:21 (Designation & Condition 51000-A, 'O')(Tensile Strength) |
- |
2000 |
|
- |
| 4.2,
Table 2 of IS:21 (Designation & Condition 40800, 'H4')(Tensile Strength) |
- |
2000 |
|
- |
| 4.2,
Table 2 of IS:21 (Designation & Condition 40800, 'H3')(Tensile Strength) |
- |
2000 |
|
- |
| 4.2,
Table 2 of IS:21 (Designation & Condition 40800, 'H2')(Tensile Strength) |
- |
2000 |
|
- |
| 4.2,
Table 2 of IS:21 (Designation & Condition 40800, 'H1')(Tensile Strength) |
- |
2000 |
|
- |
| 4.2,
Table 2 of IS:21 (Designation & Condition 40800, 'O')(Tensile Strength) |
- |
2000 |
|
- |
| 4.2,
Table 2 of IS:21 (Designation & Condition 31500, 'H4')(Tensile Strength) |
- |
2000 |
|
- |
| 4.2,
Table 2 of IS:21 (Designation & Condition 31500, 'H3')(Tensile Strength) |
- |
2000 |
|
- |
| 4.2,
Table 2 of IS:21 (Designation & Condition 31500, 'H2')(Tensile Strength) |
- |
2000 |
|
- |
| 4.2,
Table 2 of IS:21 (Designation & Condition 31500, 'H1')(Tensile Strength) |
- |
2000 |
|
- |
| 4.2,
Table 2 of IS:21 (Designation & Condition 31500, 'O')(Tensile Strength) |
- |
2000 |
|
- |
| 4.2,
Table 2 of IS:21 (Designation & Condition 31000, 'H4')(Tensile Strength) |
- |
2000 |
|
- |
| 4.2,
Table 2 of IS:21 (Designation & Condition 31000, 'H3')(Tensile Strength) |
- |
2000 |
|
- |
| 4.2,
Table 2 of IS:21 (Designation & Condition 31000, 'H2')(Tensile Strength) |
- |
2000 |
|
- |
| 4.2,
Table 2 of IS:21 (Designation & Condition 31000, 'H1')(Tensile Strength) |
- |
2000 |
|
- |
| 4.2,
Table 2 of IS:21 (Designation & Condition 31000, 'O')(Tensile Strength) |
- |
2000 |
|
- |
| 4.2,
Table 2 of IS:21 (Designation & Condition 19600, 'H4')(Tensile Strength) |
- |
2000 |
|
- |
| 4.2,
Table 2 of IS:21 (Designation & Condition 19600, 'H2')(Tensile Strength) |
- |
2000 |
|
- |
| 4.2,
Table 2 of IS:21 (Designation & Condition 19600, 'O')(Tensile Strength) |
- |
2000 |
|
- |
| 4.2,
Table 2 of IS:21 (Designation & Condition 19500, 'H4')(Tensile Strength) |
- |
2000 |
|
- |
| 4.2,
Table 2 of IS:21 (Designation & Condition 19500, 'H2')(Tensile Strength) |
- |
2000 |
|
- |
| 4.2,
Table 2 of IS:21 (Designation & Condition 19500, 'O')(Tensile Strength) |
- |
2000 |
|
- |
| 4.2,
Table 2 of IS:21 (Designation & Condition 19000, 'H4')(Tensile Strength) |
- |
2000 |
|
- |
| 4.2,
Table 2 of IS:21 (Designation & Condition 19000, 'H3')(Tensile Strength) |
- |
2000 |
|
- |
| 4.2,
Table 2 of IS:21 (Designation & Condition 19000, 'H2')(Tensile Strength) |
- |
2000 |
|
- |
| 4.2,
Table 2 of IS:21 (Designation & Condition 19000, 'H1')(Tensile Strength) |
- |
2000 |
|
- |
| 4.2,
Table 2 of IS:21 (Designation & Condition 19000, 'O')(Tensile Strength) |
- |
2000 |
|
- |
| 4.2,
Table 2 of IS:21 (Designation & Condition 64430, WP')(0.2 Percent Proof Stress) |
- |
2000 |
|
- |
| 4.2,
Table 2 of IS:21 (Designation & Condition 64430, 'W')(0.2 Percent Proof Stress) |
- |
2000 |
|
- |
| 4.2,
Table 2 of IS:21 (Designation & Condition 51000-B, 'H3')(0.2 Percent Proof Stress) |
- |
2000 |
|
- |
| 4.2,
Table 2 of IS:21 (Designation & Condition 51000-B, 'H2')(0.2 Percent Proof Stress) |
- |
2000 |
|
- |
| 4.2,
Table 2 of IS:21 (Designation & Condition 51000-B, 'H1')(0.2 Percent Proof Stress) |
- |
2000 |
|
- |
| 4.2,
Table 2 of IS:21 (Designation & Condition 51000-A, 'H3')(0.2 Percent Proof Stress) |
- |
2000 |
|
- |
| 4.2,
Table 2 of IS:21 (Designation & Condition 51000-A, 'H2')(0.2 Percent Proof Stress) |
- |
2000 |
|
- |
| 4.2,
Table 2 of IS:21 (Designation & Condition 51000-A, 'H1')(0.2 Percent Proof Stress) |
- |
2000 |
|
- |
| 4.2,
Table 2 of IS:21 (Designation & Condition 64430, WP')(Elongation on 50 mm gauge length (For thickness over 2.6 to 6.3 mm)) |
- |
2000 |
|
- |
| 4.2,
Table 2 of IS:21 (Designation & Condition 64430, 'W')(Elongation on 50 mm gauge length (For thickness over 2.6 to 6.3 mm)) |
- |
2000 |
|
- |
| 4.2,
Table 2 of IS:21 (Designation & Condition 64430, 'O')(Elongation on 50 mm gauge length (For thickness over 2.6 to 6.3 mm)) |
- |
2000 |
|
- |
| 4.2,
Table 2 of IS:21 (Designation & Condition 51000-B, 'H4')(Elongation on 50 mm gauge length (For thickness over 2.6 to 6.3 mm)) |
- |
2000 |
|
- |
| 4.2,
Table 2 of IS:21 (Designation & Condition 51000-B, 'H3')(Elongation on 50 mm gauge length (For thickness over 2.6 to 6.3 mm)) |
- |
2000 |
|
- |
| 4.2,
Table 2 of IS:21 (Designation & Condition 51000-B, 'H2')(Elongation on 50 mm gauge length (For thickness over 2.6 to 6.3 mm)) |
- |
2000 |
|
- |
| 4.2,
Table 2 of IS:21 (Designation & Condition 51000-B, 'H1')(Elongation on 50 mm gauge length (For thickness over 2.6 to 6.3 mm)) |
- |
2000 |
|
- |
| 4.2,
Table 2 of IS:21 (Designation & Condition 51000-A, 'H3')(Elongation on 50 mm gauge length (For thickness over 2.6 to 6.3 mm)) |
- |
2000 |
|
- |
| 4.2,
Table 2 of IS:21 (Designation & Condition 51000-A, 'H2')(Elongation on 50 mm gauge length (For thickness over 2.6 to 6.3 mm)) |
- |
2000 |
|
- |
| 4.2,
Table 2 of IS:21 (Designation & Condition 51000-A, 'H1')(Elongation on 50 mm gauge length (For thickness over 2.6 to 6.3 mm)) |
- |
2000 |
|
- |
| 4.2,
Table 2 of IS:21 (Designation & Condition 51000-A, 'O')(Elongation on 50 mm gauge length (For thickness over 2.6 to 6.3 mm)) |
- |
2000 |
|
- |
| 4.2,
Table 2 of IS:21 (Designation & Condition 40800, 'H4')(Elongation on 50 mm gauge length (For thickness over 2.6 to 6.3 mm)) |
- |
2000 |
|
- |
| 4.2,
Table 2 of IS:21 (Designation & Condition 40800, 'H3')(Elongation on 50 mm gauge length (For thickness over 2.6 to 6.3 mm)) |
- |
2000 |
|
- |
| 4.2,
Table 2 of IS:21 (Designation & Condition 40800, 'H2')(Elongation on 50 mm gauge length (For thickness over 2.6 to 6.3 mm)) |
- |
2000 |
|
- |
| 4.2,
Table 2 of IS:21 (Designation & Condition 40800, 'H1')(Elongation on 50 mm gauge length (For thickness over 2.6 to 6.3 mm)) |
- |
2000 |
|
- |
| 4.2,
Table 2 of IS:21 (Designation & Condition 40800, 'O')(Elongation on 50 mm gauge length (For thickness over 2.6 to 6.3 mm)) |
- |
2000 |
|
- |
| 4.2,
Table 2 of IS:21 (Designation & Condition 31500, 'H4')(Elongation on 50 mm gauge length (For thickness over 2.6 to 6.3 mm)) |
- |
2000 |
|
- |
| 4.2,
Table 2 of IS:21 (Designation & Condition 31500, 'H3')(Elongation on 50 mm gauge length (For thickness over 2.6 to 6.3 mm)) |
- |
2000 |
|
- |
| 4.2,
Table 2 of IS:21 (Designation & Condition 31500, 'H2')(Elongation on 50 mm gauge length (For thickness over 2.6 to 6.3 mm)) |
- |
2000 |
|
- |
| 4.2,
Table 2 of IS:21 (Designation & Condition 31500, 'H1')(Elongation on 50 mm gauge length (For thickness over 2.6 to 6.3 mm)) |
- |
2000 |
|
- |
| 4.2,
Table 2 of IS:21 (Designation & Condition 31500, 'O')(Elongation on 50 mm gauge length (For thickness over 2.6 to 6.3 mm)) |
- |
2000 |
|
- |
| 4.2,
Table 2 of IS:21 (Designation & Condition 31000, 'H4')(Elongation on 50 mm gauge length (For thickness over 2.6 to 6.3 mm)) |
- |
2000 |
|
- |
| 4.2,
Table 2 of IS:21 (Designation & Condition 31000, 'H3')(Elongation on 50 mm gauge length (For thickness over 2.6 to 6.3 mm)) |
- |
2000 |
|
- |
| 4.2,
Table 2 of IS:21 (Designation & Condition 31000, 'H2')(Elongation on 50 mm gauge length (For thickness over 2.6 to 6.3 mm)) |
- |
2000 |
|
- |
| 4.2,
Table 2 of IS:21 (Designation & Condition 31000, 'H1')(Elongation on 50 mm gauge length (For thickness over 2.6 to 6.3 mm)) |
- |
2000 |
|
- |
| 4.2,
Table 2 of IS:21 (Designation & Condition 31000, 'O')(Elongation on 50 mm gauge length (For thickness over 2.6 to 6.3 mm)) |
- |
2000 |
|
- |
| 4.2,
Table 2 of IS:21 (Designation & Condition 19600, 'H4')(Elongation on 50 mm gauge length (For thickness over 2.6 to 6.3 mm)) |
- |
2000 |
|
- |
| 4.2,
Table 2 of IS:21 (Designation & Condition 19600, 'H2')(Elongation on 50 mm gauge length (For thickness over 2.6 to 6.3 mm)) |
- |
2000 |
|
- |
| 4.2,
Table 2 of IS:21 (Designation & Condition 19600, 'O')(Elongation on 50 mm gauge length (For thickness over 2.6 to 6.3 mm)) |
- |
2000 |
|
- |
| 4.2,
Table 2 of IS:21 (Designation & Condition 19500, 'H4')(Elongation on 50 mm gauge length (For thickness over 2.6 to 6.3 mm)) |
- |
2000 |
|
- |
| 4.2,
Table 2 of IS:21 (Designation & Condition 19500, 'H2')(Elongation on 50 mm gauge length (For thickness over 2.6 to 6.3 mm)) |
- |
2000 |
|
- |
| 4.2,
Table 2 of IS:21 (Designation & Condition 19500, 'O')(Elongation on 50 mm gauge length (For thickness over 2.6 to 6.3 mm)) |
- |
2000 |
|
- |
| 4.2,
Table 2 of IS:21 (Designation & Condition 19000, 'H4')(Elongation on 50 mm gauge length (For thickness over 2.6 to 6.3 mm)) |
- |
2000 |
|
- |
| 4.2,
Table 2 of IS:21 (Designation & Condition 19000, 'H3')(Elongation on 50 mm gauge length (For thickness over 2.6 to 6.3 mm)) |
- |
2000 |
|
- |
| 4.2,
Table 2 of IS:21 (Designation & Condition 19000, 'H2')(Elongation on 50 mm gauge length (For thickness over 2.6 to 6.3 mm)) |
- |
2000 |
|
- |
| 4.2,
Table 2 of IS:21 (Designation & Condition 19000, 'H1')(Elongation on 50 mm gauge length (For thickness over 2.6 to 6.3 mm)) |
- |
2000 |
|
- |
| 4.2,
Table 2 of IS:21 (Designation & Condition 19000, 'O')(Elongation on 50 mm gauge length (For thickness over 2.6 to 6.3 mm)) |
- |
2000 |
|
- |
| 4.2,
Table 2 of IS:21 (Designation & Condition 64430, WP')(Bend Test (Radius of Bend)) |
- |
2000 |
|
- |
| 4.2,
Table 2 of IS:21 (Designation & Condition 64430, 'W')(Bend Test (Radius of Bend)) |
- |
2000 |
|
- |
| 4.2,
Table 2 of IS:21 (Designation & Condition 64430, 'O')(Bend Test (Radius of Bend)) |
- |
2000 |
|
- |
| 4.2,
Table 2 of IS:21 (Designation & Condition 51000-B, 'H4')(Bend Test (Radius of Bend)) |
- |
2000 |
|
- |
| 4.2,
Table 2 of IS:21 (Designation & Condition 51000-B, 'H3')(Bend Test (Radius of Bend)) |
- |
2000 |
|
- |
| 4.2,
Table 2 of IS:21 (Designation & Condition 51000-B, 'H2')(Bend Test (Radius of Bend)) |
- |
2000 |
|
- |
| 4.2,
Table 2 of IS:21 (Designation & Condition 51000-B, 'H1')(Bend Test (Radius of Bend)) |
- |
2000 |
|
- |
| 4.2,
Table 2 of IS:21 (Designation & Condition 51000-A, 'H3')(Bend Test (Radius of Bend)) |
- |
2000 |
|
- |
| 4.2,
Table 2 of IS:21 (Designation & Condition 51000-A, 'H2')(Bend Test (Radius of Bend)) |
- |
2000 |
|
- |
| 4.2,
Table 2 of IS:21 (Designation & Condition 51000-A, 'H1')(Bend Test (Radius of Bend)) |
- |
2000 |
|
- |
| 4.2,
Table 2 of IS:21 (Designation & Condition 51000-A, 'O')(Bend Test (Radius of Bend)) |
- |
2000 |
|
- |
| 4.2,
Table 2 of IS:21 (Designation & Condition 40800, 'H4')(Bend Test (Radius of Bend)) |
- |
2000 |
|
- |
| 4.2,
Table 2 of IS:21 (Designation & Condition 40800, 'H3')(Bend Test (Radius of Bend)) |
- |
2000 |
|
- |
| 4.2,
Table 2 of IS:21 (Designation & Condition 40800, 'H2')(Bend Test (Radius of Bend)) |
- |
2000 |
|
- |
| 4.2,
Table 2 of IS:21 (Designation & Condition 40800, 'H1')(Bend Test (Radius of Bend)) |
- |
2000 |
|
- |
| 4.2,
Table 2 of IS:21 (Designation & Condition 40800, 'O')(Bend Test (Radius of Bend)) |
- |
2000 |
|
- |
| 4.2,
Table 2 of IS:21 (Designation & Condition 31500, 'H4')(Bend Test (Radius of Bend)) |
- |
2000 |
|
- |
| 4.2,
Table 2 of IS:21 (Designation & Condition 31500, 'H3')(Bend Test (Radius of Bend)) |
- |
2000 |
|
- |
| 4.2,
Table 2 of IS:21 (Designation & Condition 31500, 'H2')(Bend Test (Radius of Bend)) |
- |
2000 |
|
- |
| 4.2,
Table 2 of IS:21 (Designation & Condition 31500, 'H1')(Bend Test (Radius of Bend)) |
- |
2000 |
|
- |
| 4.2,
Table 2 of IS:21 (Designation & Condition 31500, 'O')(Bend Test (Radius of Bend)) |
- |
2000 |
|
- |
| 4.2,
Table 2 of IS:21 (Designation & Condition 31000, 'H4')(Bend Test (Radius of Bend)) |
- |
2000 |
|
- |
| 4.2,
Table 2 of IS:21 (Designation & Condition 31000, 'H3')(Bend Test (Radius of Bend)) |
- |
2000 |
|
- |
| 4.2,
Table 2 of IS:21 (Designation & Condition 31000, 'H2')(Bend Test (Radius of Bend)) |
- |
2000 |
|
- |
| 4.2,
Table 2 of IS:21 (Designation & Condition 31000, 'H1')(Bend Test (Radius of Bend)) |
- |
2000 |
|
- |
| 4.2,
Table 2 of IS:21 (Designation & Condition 31000, 'O')(Bend Test (Radius of Bend)) |
- |
2000 |
|
- |
| 4.2,
Table 2 of IS:21 (Designation & Condition 19600, 'H4')(Bend Test (Radius of Bend)) |
- |
2000 |
|
- |
| 4.2,
Table 2 of IS:21 (Designation & Condition 19600, 'H2')(Bend Test (Radius of Bend)) |
- |
2000 |
|
- |
| 4.2,
Table 2 of IS:21 (Designation & Condition 19600, 'O')(Bend Test (Radius of Bend)) |
- |
2000 |
|
- |
| 4.2,
Table 2 of IS:21 (Designation & Condition 19500, 'H4')(Bend Test (Radius of Bend)) |
- |
2000 |
|
- |
| 4.2,
Table 2 of IS:21 (Designation & Condition 19500, 'H2')(Bend Test (Radius of Bend)) |
- |
2000 |
|
- |
| 4.2,
Table 2 of IS:21 (Designation & Condition 19500, 'O')(Bend Test (Radius of Bend)) |
- |
2000 |
|
- |
| 4.2,
Table 2 of IS:21 (Designation & Condition 19000, 'H4')(Bend Test (Radius of Bend)) |
- |
2000 |
|
- |
| 4.2,
Table 2 of IS:21 (Designation & Condition 19000, 'H3')(Bend Test (Radius of Bend)) |
- |
2000 |
|
- |
| 4.2,
Table 2 of IS:21 (Designation & Condition 19000, 'H2')(Bend Test (Radius of Bend)) |
- |
2000 |
|
- |
| 4.2,
Table 2 of IS:21 (Designation & Condition 19000, 'H1')(Bend Test (Radius of Bend)) |
- |
2000 |
|
- |
| 4.2,
Table 2 of IS:21 (Designation & Condition 19000, 'O')(Bend Test (Radius of Bend)) |
- |
2000 |
|
- |
| 5(Marking) |
- |
300 |
|
- |
|
- |
- - |
| 7096 |
Ace Test Labs & Metrology Pvt. Ltd., Sonipat
| 9162826
| IS 11188 : Part 1 (2021) |
Vault Strong Room doors Part 1 specification |
- |
298000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 11.1 (3)(Fire and stream hose IS 11188 (Part 3)) |
- |
15000 |
|
- |
| 11.1 (2)(Fire endurance IS 11188 (Part 3)) |
- |
150000 |
|
- |
| 11.1 (1)(Burglary resistance IS 11188 (Part 2)) |
- |
150000 |
|
- |
| 10.4(Alternate to Cl 10.4) |
- |
15000 |
|
- |
| 10.3(Cross Hatch Test) |
- |
15000 |
|
- |
| 10(FINISH) |
- |
15000 |
|
- |
| 9.4(Vault Lighting Control) |
- |
15000 |
|
- |
| 9.3(Foot Bridge) |
- |
15000 |
|
- |
| 9.2(Handles) |
- |
15000 |
|
- |
| 9.1.1(Adjusting Bolt) |
- |
15000 |
|
- |
| 9.1(Hinges) |
- |
15000 |
|
- |
| 9(DOOR FITTINGS) |
- |
15000 |
|
- |
| 8.4.5(Automatic Relocking Device) |
- |
15000 |
|
- |
| 8.4.4(Time Lock) |
- |
15000 |
|
- |
| 8.4(Lock) |
- |
15000 |
|
- |
| 8.3.2.2(Construction) |
- |
15000 |
|
- |
| 8.3.2.1(The number of bolts and their minimum dimension) |
- |
15000 |
|
- |
| 8.3.2(Bolt Work) |
- |
15000 |
|
- |
| 8.3.1(Lock Case) |
- |
15000 |
|
- |
| 8.3(Locking Mechanism) |
- |
15000 |
|
- |
| 8.2.3(Crane Hinge Mechanism) |
- |
15000 |
|
- |
| 8.2.2(Compression Mechanism) |
- |
15000 |
|
- |
| 8.2.1(Rebate of the Door Frame) |
- |
15000 |
|
- |
| 8.2(Doors Frame) |
- |
15000 |
|
- |
| 8.1.2(Main Door (Outside)) |
- |
15000 |
|
- |
| 8.1.1(Ventilating Grill Gate (Inside)) |
- |
15000 |
|
- |
| 8.1 Fig. 1(Doors) |
- |
15000 |
|
- |
| 8(CONSTRUCTION AND GENERALREQUIREMENTS) |
- |
15000 |
|
- |
| 5 Table 1(bolts, Min) |
- |
15000 |
|
- |
| 5 Table 1(xix) Depth of engagement of shooting) |
- |
15000 |
|
- |
| 5 Table 1(cross sectional area, Min,sq mm) |
- |
15000 |
|
- |
| 5 Table 1(xviii) Diameter of shooting bolts, Min) |
- |
15000 |
|
- |
| 5 Table 1(xvi) Number of shooting bolts at top,Min) |
- |
15000 |
|
- |
| 5 Table 1(xv) Number of shooting bolts on opposite side,Min) |
- |
15000 |
|
- |
| 5 Table 1(xiv) Number of shooting bolts on hinge side, Min) |
- |
15000 |
|
- |
| 5 Table 1(xiii) Number of locks) |
- |
15000 |
|
- |
| 5 Table 1(xii) Wall thickness (recommendation)) |
- |
15000 |
|
- |
| 5 Table 1(xi) Thickness of drill and oxyacetylene
torch resisting layer (excluding mild steel plates),Min) |
- |
15000 |
|
- |
| 5 Table 1(ix) Thickness of doors slab, thickness over rebate) |
- |
15000 |
|
- |
| 5 Table 1(viii) Pitch of grill gate rods) |
- |
15000 |
|
- |
| 5 Table 1(vii) Diameter of grill gate rods, Min) |
- |
15000 |
|
- |
| 5 Table 1(vi) Thickens of grill gate angles or
section made out of M.S. plates, Min) |
- |
15000 |
|
- |
| 5 Table 1(v) Dimension of the rebate coming under shear) |
- |
15000 |
|
- |
| 5 Table 1(iv (b) Thickness of door frame, if
fabricated from single plate to form
channel/multi-bend section, Min) |
- |
15000 |
|
- |
| 5 Table 1(ii (a) Height H, Min b) Width W, Min
iv(a) Thickness of door frame angle,
channel or section made out of M.S.
plates, if built up to form a channel,Min) |
- |
15000 |
|
- |
| 5 Table 1(iii) Inside dimension or clear opening when
door shutters are swung open at 180 degree) |
- |
15000 |
|
- |
| 5 Table 1(ii (b) Width W) |
- |
15000 |
|
- |
| 5 Table 1(ii (a) Height, H) |
- |
15000 |
|
- |
| 5 Table 1(ii) Overall dimension of vault door) |
- |
15000 |
|
- |
| 5 Table 1(i) Door Type) |
- |
15000 |
|
- |
| 4(Type) |
- |
15000 |
|
- |
| 5(Table-1)(Type of Door) |
- |
15000 |
|
- |
| 5(Table-1)(Overall dimesion of door) |
- |
15000 |
|
- |
| 5(Table-1)(Inside dimension or clear opening of door) |
- |
15000 |
|
- |
| 5(Table-1)(Thickness of door frame angle-made of Plate,if bulit up to form a channel) |
- |
15000 |
|
- |
| 5(Table-1)(Thickness of door frame ,if fabricated or multibend) |
- |
15000 |
|
- |
| 5(Table-1)(Dimension of the rebate coming under share) |
- |
15000 |
|
- |
| 5(Table-1)(Thickness of grill gate angle/section) |
- |
15000 |
|
- |
| 5(Table-1)(Diameter of grill gate rod) |
- |
15000 |
|
- |
| 5(Table-1)(Pitch of grill gate rod) |
- |
15000 |
|
- |
| 5(Table-1)(Thickness of door slab,thickness over rebate) |
- |
15000 |
|
- |
| 5(Table-1)(Thickness of the door over lock) |
- |
15000 |
|
- |
| 5(Table-1)(Thickness of drill & oxyacetylene torch resis. layer(exclue MS plate) |
- |
15000 |
|
- |
| 5(Table-1)(Wall thickness) |
- |
15000 |
|
- |
| 5(Table-1)(Number of locks) |
- |
15000 |
|
- |
| 5(Table-1)(Number of shooting bolys on hinge side) |
- |
15000 |
|
- |
| 5(Table-1)(Number of shooting bolts on opposite) |
- |
15000 |
|
- |
| 5(Table-1)(Number of shooting bolts at top) |
- |
15000 |
|
- |
| 5(Table-1)(Number of shooting bolts at bottom) |
- |
15000 |
|
- |
| 5(Table-1)(Cross sectional area as per shooting bolt) |
- |
15000 |
|
- |
| 5(Table-1)(Depth engagement of shooting) |
- |
15000 |
|
- |
| 6(Materail) |
- |
15000 |
|
- |
| 7(Classification) |
- |
15000 |
|
- |
| 8 & 8.1.1(Ventilating Grill Gate (Inside)) |
- |
15000 |
|
- |
| 8.1.1.1(Locking device (unpickable dual control lock)) |
- |
15000 |
|
- |
| 8.1.2(Main Door- Outer & inner plate thickness) |
- |
15000 |
|
- |
| 8.1.2.1(Door(Finish &Gap of frame/edge with any place)) |
- |
15000 |
|
- |
| 8.2(Door frame (No.of barckets & Size for gripping)) |
- |
15000 |
|
- |
| 8.2.1(Rebate of the door frame) |
- |
15000 |
|
- |
| 8.2.2(Compression mechanism) |
- |
15000 |
|
- |
| 8.2.3(Crane hinge mechanism) |
- |
15000 |
|
- |
| 8.3(Lock case) |
- |
15000 |
|
- |
| 8.3.2(Bolt work) |
- |
15000 |
|
- |
| 8.3.2.2(Construction (of bolt work)) |
- |
15000 |
|
- |
| 8.3.2.3(Bearing piller) |
- |
15000 |
|
- |
| 8.4.1(Shooting bolt control (By lock)) |
- |
15000 |
|
- |
| 8.4.2(Test of key-Lock) |
- |
15000 |
|
- |
| 8.4.3(Lock fixing bolts) |
- |
15000 |
|
- |
| 8.4.4(Time lock) |
- |
15000 |
|
- |
| 8.4.5(Automatic Relocking devise) |
- |
15000 |
|
- |
| 9 &9.1(Hinges) |
- |
15000 |
|
- |
| 9.1.1(Adjusting bolt) |
- |
15000 |
|
- |
| 9.2(Handles) |
- |
15000 |
|
- |
| 9.3(Foot bringe) |
- |
15000 |
|
- |
| 9.4(Vault lighting control) |
- |
15000 |
|
- |
| 10 &10.1(Dents,Burrs & Edges) |
- |
15000 |
|
- |
| 10.2(Colour coating thickness (Surafce paint)) |
- |
15000 |
|
- |
| 10.3(Cross Hatch test) |
- |
15000 |
|
- |
| 10.4(Door (Stainless cladding)) |
- |
15000 |
|
- |
| 11.1 &11.2(Test criteria for confomity -Burglaty attack) |
- |
15000 |
|
- |
| 11.1 &11.2(Test criteria for confomity -Fire resistancey) |
- |
15000 |
|
- |
| 12(Marking of door) |
- |
15000 |
|
- |
| 12.2(Marking on keys) |
- |
15000 |
|
- |
| 4(Type) |
- |
15000 |
|
- |
| 5(Table-1)(5(Table-1)) |
- |
15000 |
|
- |
| 5(Table-1)(Overall dimesion of door) |
- |
15000 |
|
- |
| 5(Table-1)(Inside dimension or clear opening of door) |
- |
15000 |
|
- |
| 5(Table-1)(Thickness of door frame angle-made of Plate,if bulit up to form a channel) |
- |
15000 |
|
- |
| 5(Table-1)(Thickness of door frame ,if fabricated or multibend) |
- |
15000 |
|
- |
| 5(Table-1)(Dimension of the rebate coming under share) |
- |
15000 |
|
- |
| 5(Table-1)(Thickness of grill gate angle/section) |
- |
15000 |
|
- |
| 5(Table-1)(Diameter of grill gate rod) |
- |
15000 |
|
- |
| 5(Table-1)(Pitch of grill gate rod) |
- |
15000 |
|
- |
| 5(Table-1)(Thickness of door slab,thickness over rebate) |
- |
15000 |
|
- |
| 5(Table-1)(Thickness of the door over lock) |
- |
15000 |
|
- |
| 5(Table-1)(Thickness of drill & oxyacetylene torch resis. layer(exclue MS plate) |
- |
15000 |
|
- |
| 5(Table-1)(Wall thickness) |
- |
15000 |
|
- |
| 5(Table-1)(Number of locks) |
- |
15000 |
|
- |
| 5(Table-1)(Number of shooting bolys on hinge side) |
- |
15000 |
|
- |
| 5(Table-1)(Number of shooting bolts at top) |
- |
15000 |
|
- |
| 5(Table-1)(Number of shooting bolts at bottom) |
- |
15000 |
|
- |
| 5(Table-1)(Cross sectional area as per shooting bolt) |
- |
15000 |
|
- |
| 5(Table-1)(Depth engagement of shooting) |
- |
15000 |
|
- |
| 6(Materail) |
- |
15000 |
|
- |
| 7(Classification) |
- |
15000 |
|
- |
| 8 & 8.1.1(Ventilating Grill Gate (Inside)) |
- |
15000 |
|
- |
| 8.1.1.1(Locking device (unpickable dual control lock)) |
- |
15000 |
|
- |
| 8.1.2(Main Door- Outer & inner plate thickness) |
- |
15000 |
|
- |
| 8.1.2.1(Door(Finish &Gap of frame/edge with any place)) |
- |
15000 |
|
- |
| 8.2(Door frame (No.of barckets & Size for gripping)) |
- |
15000 |
|
- |
| 8.2.1(Rebate of the door frame) |
- |
15000 |
|
- |
| 8.2.2(Compression mechanism) |
- |
15000 |
|
- |
| 8.2.3(Crane hinge mechanism) |
- |
15000 |
|
- |
| 8.3(Lock case) |
- |
15000 |
|
- |
| 8.3.2(Bolt work) |
- |
15000 |
|
- |
| 8.3.2.2(Construction (of bolt work)) |
- |
15000 |
|
- |
| 8.3.2.3(Bearing piller) |
- |
15000 |
|
- |
| 8.4.1(Shooting bolt control (By lock)) |
- |
15000 |
|
- |
| 8.4.2(Test of key-Lock) |
- |
15000 |
|
- |
| 8.4.3(Lock fixing bolts) |
- |
15000 |
|
- |
| 8.4.4(Time lock) |
- |
15000 |
|
- |
| 8.4.5(Automatic Relocking devise) |
- |
15000 |
|
- |
| 9 &9.1(Hinges) |
- |
15000 |
|
- |
| 9.1.1(Adjusting bolt) |
- |
15000 |
|
- |
| 9.3(Foot bringe) |
- |
15000 |
|
- |
| 9.4(Vault lighting control) |
- |
15000 |
|
- |
| 10 &10.1(Dents,Burrs & Edges) |
- |
15000 |
|
- |
| 10.2(Colour coating thickness (Surafce paint)) |
- |
15000 |
|
- |
| 10.3(Cross Hatch test) |
- |
15000 |
|
- |
| 10.4(Door (Stainless cladding)) |
- |
15000 |
|
- |
| 11.1 &11.2(Test criteria for confomity -Burglaty attack) |
- |
15000 |
|
- |
| 11.1 &11.2(Test criteria for confomity -Fire resistancey) |
- |
15000 |
|
- |
| 12(Marking of door) |
- |
15000 |
|
- |
| 12.2(Marking on keys) |
- |
15000 |
|
- |
| 11.1 (3)(Fire and stream hose IS 11188 (Part 3)) |
- |
15000 |
|
- |
| 11.1 (2)(Fire endurance IS 11188 (Part 3)) |
- |
150000 |
|
- |
| 11.1 (1)(Burglary resistance IS 11188 (Part 2)) |
- |
150000 |
|
- |
| 10.4(Alternate to Cl 10.4) |
- |
15000 |
|
- |
| 10.3(Cross Hatch Test) |
- |
15000 |
|
- |
| 10(FINISH) |
- |
15000 |
|
- |
| 9.4(Vault Lighting Control) |
- |
15000 |
|
- |
| 9.3(Foot Bridge) |
- |
15000 |
|
- |
| 9.2(Handles) |
- |
15000 |
|
- |
| 9.1.1(Adjusting Bolt) |
- |
15000 |
|
- |
| 9.1(Hinges) |
- |
15000 |
|
- |
| 9(DOOR FITTINGS) |
- |
15000 |
|
- |
| 8.4.5(Automatic Relocking Device) |
- |
15000 |
|
- |
| 8.4.4(Time Lock) |
- |
15000 |
|
- |
| 8.4(Lock) |
- |
15000 |
|
- |
| 8.3.2.2(Construction) |
- |
15000 |
|
- |
| 8.3.2.1(The number of bolts and their minimum dimension) |
- |
15000 |
|
- |
| 8.3.2(Bolt Work) |
- |
15000 |
|
- |
| 8.3.1(Lock Case) |
- |
15000 |
|
- |
| 8.3(Locking Mechanism) |
- |
15000 |
|
- |
| 8.2.3(Crane Hinge Mechanism) |
- |
15000 |
|
- |
| 8.2.2(Compression Mechanism) |
- |
15000 |
|
- |
| 8.2.1(Rebate of the Door Frame) |
- |
15000 |
|
- |
| 8.2(Doors Frame) |
- |
15000 |
|
- |
| 8.1.2(Main Door (Outside)) |
- |
15000 |
|
- |
| 8.1.1(Ventilating Grill Gate (Inside)) |
- |
15000 |
|
- |
| 8.1 Fig. 1(Doors) |
- |
15000 |
|
- |
| 8(CONSTRUCTION AND GENERALREQUIREMENTS) |
- |
15000 |
|
- |
| 5 Table 1(bolts, Min) |
- |
15000 |
|
- |
| 5 Table 1(xix) Depth of engagement of shooting) |
- |
15000 |
|
- |
| 5 Table 1(cross sectional area, Min,sq mm) |
- |
15000 |
|
- |
| 5 Table 1(xviii) Diameter of shooting bolts, Min) |
- |
15000 |
|
- |
| 5 Table 1(xvi) Number of shooting bolts at top,Min) |
- |
15000 |
|
- |
| 5 Table 1(xv) Number of shooting bolts on opposite side,Min) |
- |
15000 |
|
- |
| 5 Table 1(xiv) Number of shooting bolts on hinge side, Min) |
- |
15000 |
|
- |
| 5 Table 1(xiii) Number of locks) |
- |
15000 |
|
- |
| 5 Table 1(xii) Wall thickness (recommendation)) |
- |
15000 |
|
- |
| 5 Table 1(xi) Thickness of drill and oxyacetylene
torch resisting layer (excluding mild steel plates),Min) |
- |
15000 |
|
- |
| 5 Table 1(ix) Thickness of doors slab, thickness over rebate) |
- |
15000 |
|
- |
| 5 Table 1(viii) Pitch of grill gate rods) |
- |
15000 |
|
- |
| 5 Table 1(vii) Diameter of grill gate rods, Min) |
- |
15000 |
|
- |
| 5 Table 1(vi) Thickens of grill gate angles or
section made out of M.S. plates, Min) |
- |
15000 |
|
- |
| 5 Table 1(v) Dimension of the rebate coming under shear) |
- |
15000 |
|
- |
| 5 Table 1(iv (b) Thickness of door frame, if
fabricated from single plate to form
channel/multi-bend section, Min) |
- |
15000 |
|
- |
| 5 Table 1(ii (a) Height H, Min b) Width W, Min
iv(a) Thickness of door frame angle,
channel or section made out of M.S.
plates, if built up to form a channel,Min) |
- |
15000 |
|
- |
| 5 Table 1(iii) Inside dimension or clear opening when
door shutters are swung open at 180 degree) |
- |
15000 |
|
- |
| 5 Table 1(ii (b) Width W) |
- |
15000 |
|
- |
| 5 Table 1(ii (a) Height, H) |
- |
15000 |
|
- |
| 5 Table 1(ii) Overall dimension of vault door) |
- |
15000 |
|
- |
| 5 Table 1(i) Door Type) |
- |
15000 |
|
- |
| 4(Type) |
- |
15000 |
|
- |
| 5(Table-1)(Type of Door) |
- |
15000 |
|
- |
| 5(Table-1)(Overall dimesion of door) |
- |
15000 |
|
- |
| 5(Table-1)(Inside dimension or clear opening of door) |
- |
15000 |
|
- |
| 5(Table-1)(Thickness of door frame angle-made of Plate,if bulit up to form a channel) |
- |
15000 |
|
- |
| 5(Table-1)(Thickness of door frame ,if fabricated or multibend) |
- |
15000 |
|
- |
| 5(Table-1)(Dimension of the rebate coming under share) |
- |
15000 |
|
- |
| 5(Table-1)(Thickness of grill gate angle/section) |
- |
15000 |
|
- |
| 5(Table-1)(Diameter of grill gate rod) |
- |
15000 |
|
- |
| 5(Table-1)(Pitch of grill gate rod) |
- |
15000 |
|
- |
| 5(Table-1)(Thickness of door slab,thickness over rebate) |
- |
15000 |
|
- |
| 5(Table-1)(Thickness of the door over lock) |
- |
15000 |
|
- |
| 5(Table-1)(Thickness of drill & oxyacetylene torch resis. layer(exclue MS plate) |
- |
15000 |
|
- |
| 5(Table-1)(Wall thickness) |
- |
15000 |
|
- |
| 5(Table-1)(Number of locks) |
- |
15000 |
|
- |
| 5(Table-1)(Number of shooting bolys on hinge side) |
- |
15000 |
|
- |
| 5(Table-1)(Number of shooting bolts on opposite) |
- |
15000 |
|
- |
| 5(Table-1)(Number of shooting bolts at top) |
- |
15000 |
|
- |
| 5(Table-1)(Number of shooting bolts at bottom) |
- |
15000 |
|
- |
| 5(Table-1)(Cross sectional area as per shooting bolt) |
- |
15000 |
|
- |
| 5(Table-1)(Depth engagement of shooting) |
- |
15000 |
|
- |
| 6(Materail) |
- |
15000 |
|
- |
| 7(Classification) |
- |
15000 |
|
- |
| 8 & 8.1.1(Ventilating Grill Gate (Inside)) |
- |
15000 |
|
- |
| 8.1.1.1(Locking device (unpickable dual control lock)) |
- |
15000 |
|
- |
| 8.1.2(Main Door- Outer & inner plate thickness) |
- |
15000 |
|
- |
| 8.1.2.1(Door(Finish &Gap of frame/edge with any place)) |
- |
15000 |
|
- |
| 8.2(Door frame (No.of barckets & Size for gripping)) |
- |
15000 |
|
- |
| 8.2.1(Rebate of the door frame) |
- |
15000 |
|
- |
| 8.2.2(Compression mechanism) |
- |
15000 |
|
- |
| 8.2.3(Crane hinge mechanism) |
- |
15000 |
|
- |
| 8.3(Lock case) |
- |
15000 |
|
- |
| 8.3.2(Bolt work) |
- |
15000 |
|
- |
| 8.3.2.2(Construction (of bolt work)) |
- |
15000 |
|
- |
| 8.3.2.3(Bearing piller) |
- |
15000 |
|
- |
| 8.4.1(Shooting bolt control (By lock)) |
- |
15000 |
|
- |
| 8.4.2(Test of key-Lock) |
- |
15000 |
|
- |
| 8.4.3(Lock fixing bolts) |
- |
15000 |
|
- |
| 8.4.4(Time lock) |
- |
15000 |
|
- |
| 8.4.5(Automatic Relocking devise) |
- |
15000 |
|
- |
| 9 &9.1(Hinges) |
- |
15000 |
|
- |
| 9.1.1(Adjusting bolt) |
- |
15000 |
|
- |
| 9.2(Handles) |
- |
15000 |
|
- |
| 9.3(Foot bringe) |
- |
15000 |
|
- |
| 9.4(Vault lighting control) |
- |
15000 |
|
- |
| 10 &10.1(Dents,Burrs & Edges) |
- |
15000 |
|
- |
| 10.2(Colour coating thickness (Surafce paint)) |
- |
15000 |
|
- |
| 10.3(Cross Hatch test) |
- |
15000 |
|
- |
| 10.4(Door (Stainless cladding)) |
- |
15000 |
|
- |
| 11.1 &11.2(Test criteria for confomity -Burglaty attack) |
- |
15000 |
|
- |
| 11.1 &11.2(Test criteria for confomity -Fire resistancey) |
- |
15000 |
|
- |
| 12(Marking of door) |
- |
15000 |
|
- |
| 12.2(Marking on keys) |
- |
15000 |
|
- |
| 4(Type) |
- |
15000 |
|
- |
| 5(Table-1)(5(Table-1)) |
- |
15000 |
|
- |
| 5(Table-1)(Overall dimesion of door) |
- |
15000 |
|
- |
| 5(Table-1)(Inside dimension or clear opening of door) |
- |
15000 |
|
- |
| 5(Table-1)(Thickness of door frame angle-made of Plate,if bulit up to form a channel) |
- |
15000 |
|
- |
| 5(Table-1)(Thickness of door frame ,if fabricated or multibend) |
- |
15000 |
|
- |
| 5(Table-1)(Dimension of the rebate coming under share) |
- |
15000 |
|
- |
| 5(Table-1)(Thickness of grill gate angle/section) |
- |
15000 |
|
- |
| 5(Table-1)(Diameter of grill gate rod) |
- |
15000 |
|
- |
| 5(Table-1)(Pitch of grill gate rod) |
- |
15000 |
|
- |
| 5(Table-1)(Thickness of door slab,thickness over rebate) |
- |
15000 |
|
- |
| 5(Table-1)(Thickness of the door over lock) |
- |
15000 |
|
- |
| 5(Table-1)(Thickness of drill & oxyacetylene torch resis. layer(exclue MS plate) |
- |
15000 |
|
- |
| 5(Table-1)(Wall thickness) |
- |
15000 |
|
- |
| 5(Table-1)(Number of locks) |
- |
15000 |
|
- |
| 5(Table-1)(Number of shooting bolys on hinge side) |
- |
15000 |
|
- |
| 5(Table-1)(Number of shooting bolts at top) |
- |
15000 |
|
- |
| 5(Table-1)(Number of shooting bolts at bottom) |
- |
15000 |
|
- |
| 5(Table-1)(Cross sectional area as per shooting bolt) |
- |
15000 |
|
- |
| 5(Table-1)(Depth engagement of shooting) |
- |
15000 |
|
- |
| 6(Materail) |
- |
15000 |
|
- |
| 7(Classification) |
- |
15000 |
|
- |
| 8 & 8.1.1(Ventilating Grill Gate (Inside)) |
- |
15000 |
|
- |
| 8.1.1.1(Locking device (unpickable dual control lock)) |
- |
15000 |
|
- |
| 8.1.2(Main Door- Outer & inner plate thickness) |
- |
15000 |
|
- |
| 8.1.2.1(Door(Finish &Gap of frame/edge with any place)) |
- |
15000 |
|
- |
| 8.2(Door frame (No.of barckets & Size for gripping)) |
- |
15000 |
|
- |
| 8.2.1(Rebate of the door frame) |
- |
15000 |
|
- |
| 8.2.2(Compression mechanism) |
- |
15000 |
|
- |
| 8.2.3(Crane hinge mechanism) |
- |
15000 |
|
- |
| 8.3(Lock case) |
- |
15000 |
|
- |
| 8.3.2(Bolt work) |
- |
15000 |
|
- |
| 8.3.2.2(Construction (of bolt work)) |
- |
15000 |
|
- |
| 8.3.2.3(Bearing piller) |
- |
15000 |
|
- |
| 8.4.1(Shooting bolt control (By lock)) |
- |
15000 |
|
- |
| 8.4.2(Test of key-Lock) |
- |
15000 |
|
- |
| 8.4.3(Lock fixing bolts) |
- |
15000 |
|
- |
| 8.4.4(Time lock) |
- |
15000 |
|
- |
| 8.4.5(Automatic Relocking devise) |
- |
15000 |
|
- |
| 9 &9.1(Hinges) |
- |
15000 |
|
- |
| 9.1.1(Adjusting bolt) |
- |
15000 |
|
- |
| 9.3(Foot bringe) |
- |
15000 |
|
- |
| 9.4(Vault lighting control) |
- |
15000 |
|
- |
| 10 &10.1(Dents,Burrs & Edges) |
- |
15000 |
|
- |
| 10.2(Colour coating thickness (Surafce paint)) |
- |
15000 |
|
- |
| 10.3(Cross Hatch test) |
- |
15000 |
|
- |
| 10.4(Door (Stainless cladding)) |
- |
15000 |
|
- |
| 11.1 &11.2(Test criteria for confomity -Burglaty attack) |
- |
15000 |
|
- |
| 11.1 &11.2(Test criteria for confomity -Fire resistancey) |
- |
15000 |
|
- |
| 12(Marking of door) |
- |
5000 |
|
- |
| 12.2(Marking on keys) |
- |
5000 |
|
- |
| 11.1 (3)(Fire and stream hose IS 11188 (Part 3)) |
- |
15000 |
|
- |
| 11.1 (2)(Fire endurance IS 11188 (Part 3)) |
- |
150000 |
|
- |
| 11.1 (1)(Burglary resistance IS 11188 (Part 2)) |
- |
150000 |
|
- |
| 10.4(Alternate to Cl 10.4) |
- |
15000 |
|
- |
| 10.3(Cross Hatch Test) |
- |
15000 |
|
- |
| 10(FINISH) |
- |
15000 |
|
- |
| 9.4(Vault Lighting Control) |
- |
15000 |
|
- |
| 9.3(Foot Bridge) |
- |
15000 |
|
- |
| 9.2(Handles) |
- |
15000 |
|
- |
| 9.1.1(Adjusting Bolt) |
- |
15000 |
|
- |
| 9.1(Hinges) |
- |
15000 |
|
- |
| 9(DOOR FITTINGS) |
- |
15000 |
|
- |
| 8.4.5(Automatic Relocking Device) |
- |
15000 |
|
- |
| 8.4.4(Time Lock) |
- |
15000 |
|
- |
| 8.4(Lock) |
- |
15000 |
|
- |
| 8.3.2.2(Construction) |
- |
15000 |
|
- |
| 8.3.2.1(The number of bolts and their minimum dimension) |
- |
15000 |
|
- |
| 8.3.2(Bolt Work) |
- |
15000 |
|
- |
| 8.3.1(Lock Case) |
- |
15000 |
|
- |
| 8.3(Locking Mechanism) |
- |
15000 |
|
- |
| 8.2.3(Crane Hinge Mechanism) |
- |
15000 |
|
- |
| 8.2.2(Compression Mechanism) |
- |
15000 |
|
- |
| 8.2.1(Rebate of the Door Frame) |
- |
15000 |
|
- |
| 8.2(Doors Frame) |
- |
15000 |
|
- |
| 8.1.2(Main Door (Outside)) |
- |
15000 |
|
- |
| 8.1.1(Ventilating Grill Gate (Inside)) |
- |
15000 |
|
- |
| 8.1 Fig. 1(Doors) |
- |
15000 |
|
- |
| 8(CONSTRUCTION AND GENERALREQUIREMENTS) |
- |
15000 |
|
- |
| 5 Table 1(bolts, Min) |
- |
15000 |
|
- |
| 5 Table 1(xix) Depth of engagement of shooting) |
- |
15000 |
|
- |
| 5 Table 1(cross sectional area, Min,sq mm) |
- |
15000 |
|
- |
| 5 Table 1(xviii) Diameter of shooting bolts, Min) |
- |
15000 |
|
- |
| 5 Table 1(xvi) Number of shooting bolts at top,Min) |
- |
15000 |
|
- |
| 5 Table 1(xv) Number of shooting bolts on opposite side,Min) |
- |
15000 |
|
- |
| 5 Table 1(xiv) Number of shooting bolts on hinge side, Min) |
- |
15000 |
|
- |
| 5 Table 1(xiii) Number of locks) |
- |
15000 |
|
- |
| 5 Table 1(xii) Wall thickness (recommendation)) |
- |
15000 |
|
- |
| 5 Table 1(xi) Thickness of drill and oxyacetylene
torch resisting layer (excluding mild steel plates),Min) |
- |
15000 |
|
- |
| 5 Table 1(ix) Thickness of doors slab, thickness over rebate) |
- |
15000 |
|
- |
| 5 Table 1(viii) Pitch of grill gate rods) |
- |
15000 |
|
- |
| 5 Table 1(vii) Diameter of grill gate rods, Min) |
- |
15000 |
|
- |
| 5 Table 1(vi) Thickens of grill gate angles or
section made out of M.S. plates, Min) |
- |
15000 |
|
- |
| 5 Table 1(v) Dimension of the rebate coming under shear) |
- |
15000 |
|
- |
| 5 Table 1(iv (b) Thickness of door frame, if
fabricated from single plate to form
channel/multi-bend section, Min) |
- |
15000 |
|
- |
| 5 Table 1(ii (a) Height H, Min b) Width W, Min
iv(a) Thickness of door frame angle,
channel or section made out of M.S.
plates, if built up to form a channel,Min) |
- |
15000 |
|
- |
| 5 Table 1(iii) Inside dimension or clear opening when
door shutters are swung open at 180 degree) |
- |
15000 |
|
- |
| 5 Table 1(ii (b) Width W) |
- |
15000 |
|
- |
| 5 Table 1(ii (a) Height, H) |
- |
15000 |
|
- |
| 5 Table 1(ii) Overall dimension of vault door) |
- |
15000 |
|
- |
| 5 Table 1(i) Door Type) |
- |
15000 |
|
- |
| 4(Type) |
- |
15000 |
|
- |
| 5(Table-1)(Type of Door) |
- |
15000 |
|
- |
| 5(Table-1)(Overall dimesion of door) |
- |
15000 |
|
- |
| 5(Table-1)(Inside dimension or clear opening of door) |
- |
15000 |
|
- |
| 5(Table-1)(Thickness of door frame angle-made of Plate,if bulit up to form a channel) |
- |
15000 |
|
- |
| 5(Table-1)(Thickness of door frame ,if fabricated or multibend) |
- |
15000 |
|
- |
| 5(Table-1)(Dimension of the rebate coming under share) |
- |
15000 |
|
- |
| 5(Table-1)(Thickness of grill gate angle/section) |
- |
15000 |
|
- |
| 5(Table-1)(Diameter of grill gate rod) |
- |
15000 |
|
- |
| 5(Table-1)(Pitch of grill gate rod) |
- |
15000 |
|
- |
| 5(Table-1)(Thickness of door slab,thickness over rebate) |
- |
15000 |
|
- |
| 5(Table-1)(Thickness of the door over lock) |
- |
15000 |
|
- |
| 5(Table-1)(Thickness of drill & oxyacetylene torch resis. layer(exclue MS plate) |
- |
15000 |
|
- |
| 5(Table-1)(Wall thickness) |
- |
15000 |
|
- |
| 5(Table-1)(Number of locks) |
- |
15000 |
|
- |
| 5(Table-1)(Number of shooting bolys on hinge side) |
- |
15000 |
|
- |
| 5(Table-1)(Number of shooting bolts on opposite) |
- |
15000 |
|
- |
| 5(Table-1)(Number of shooting bolts at top) |
- |
15000 |
|
- |
| 5(Table-1)(Number of shooting bolts at bottom) |
- |
15000 |
|
- |
| 5(Table-1)(Cross sectional area as per shooting bolt) |
- |
15000 |
|
- |
| 5(Table-1)(Depth engagement of shooting) |
- |
15000 |
|
- |
| 6(Materail) |
- |
15000 |
|
- |
| 7(Classification) |
- |
15000 |
|
- |
| 8 & 8.1.1(Ventilating Grill Gate (Inside)) |
- |
15000 |
|
- |
| 8.1.1.1(Locking device (unpickable dual control lock)) |
- |
15000 |
|
- |
| 8.1.2(Main Door- Outer & inner plate thickness) |
- |
15000 |
|
- |
| 8.1.2.1(Door(Finish &Gap of frame/edge with any place)) |
- |
15000 |
|
- |
| 8.2(Door frame (No.of barckets & Size for gripping)) |
- |
15000 |
|
- |
| 8.2.1(Rebate of the door frame) |
- |
15000 |
|
- |
| 8.2.2(Compression mechanism) |
- |
15000 |
|
- |
| 8.2.3(Crane hinge mechanism) |
- |
15000 |
|
- |
| 8.3(Lock case) |
- |
15000 |
|
- |
| 8.3.2(Bolt work) |
- |
15000 |
|
- |
| 8.3.2.2(Construction (of bolt work)) |
- |
15000 |
|
- |
| 8.3.2.3(Bearing piller) |
- |
15000 |
|
- |
| 8.4.1(Shooting bolt control (By lock)) |
- |
15000 |
|
- |
| 8.4.2(Test of key-Lock) |
- |
15000 |
|
- |
| 8.4.3(Lock fixing bolts) |
- |
15000 |
|
- |
| 8.4.4(Time lock) |
- |
15000 |
|
- |
| 8.4.5(Automatic Relocking devise) |
- |
15000 |
|
- |
| 9 &9.1(Hinges) |
- |
15000 |
|
- |
| 9.1.1(Adjusting bolt) |
- |
15000 |
|
- |
| 9.2(Handles) |
- |
15000 |
|
- |
| 9.3(Foot bringe) |
- |
15000 |
|
- |
| 9.4(Vault lighting control) |
- |
15000 |
|
- |
| 10 &10.1(Dents,Burrs & Edges) |
- |
15000 |
|
- |
| 10.2(Colour coating thickness (Surafce paint)) |
- |
15000 |
|
- |
| 10.3(Cross Hatch test) |
- |
15000 |
|
- |
| 10.4(Door (Stainless cladding)) |
- |
15000 |
|
- |
| 11.1 &11.2(Test criteria for confomity -Burglaty attack) |
- |
15000 |
|
- |
| 11.1 &11.2(Test criteria for confomity -Fire resistancey) |
- |
15000 |
|
- |
| 12(Marking of door) |
- |
15000 |
|
- |
| 12.2(Marking on keys) |
- |
15000 |
|
- |
| 4(Type) |
- |
15000 |
|
- |
| 5(Table-1)(5(Table-1)) |
- |
15000 |
|
- |
| 5(Table-1)(Overall dimesion of door) |
- |
15000 |
|
- |
| 5(Table-1)(Inside dimension or clear opening of door) |
- |
15000 |
|
- |
| 5(Table-1)(Thickness of door frame angle-made of Plate,if bulit up to form a channel) |
- |
15000 |
|
- |
| 5(Table-1)(Thickness of door frame ,if fabricated or multibend) |
- |
15000 |
|
- |
| 5(Table-1)(Dimension of the rebate coming under share) |
- |
15000 |
|
- |
| 5(Table-1)(Thickness of grill gate angle/section) |
- |
15000 |
|
- |
| 5(Table-1)(Diameter of grill gate rod) |
- |
15000 |
|
- |
| 5(Table-1)(Pitch of grill gate rod) |
- |
15000 |
|
- |
| 5(Table-1)(Thickness of door slab,thickness over rebate) |
- |
15000 |
|
- |
| 5(Table-1)(Thickness of the door over lock) |
- |
15000 |
|
- |
| 5(Table-1)(Thickness of drill & oxyacetylene torch resis. layer(exclue MS plate) |
- |
15000 |
|
- |
| 5(Table-1)(Wall thickness) |
- |
15000 |
|
- |
| 5(Table-1)(Number of locks) |
- |
15000 |
|
- |
| 5(Table-1)(Number of shooting bolys on hinge side) |
- |
15000 |
|
- |
| 5(Table-1)(Number of shooting bolts at top) |
- |
15000 |
|
- |
| 5(Table-1)(Number of shooting bolts at bottom) |
- |
15000 |
|
- |
| 5(Table-1)(Cross sectional area as per shooting bolt) |
- |
15000 |
|
- |
| 5(Table-1)(Depth engagement of shooting) |
- |
15000 |
|
- |
| 6(Materail) |
- |
15000 |
|
- |
| 7(Classification) |
- |
15000 |
|
- |
| 8 & 8.1.1(Ventilating Grill Gate (Inside)) |
- |
15000 |
|
- |
| 8.1.1.1(Locking device (unpickable dual control lock)) |
- |
15000 |
|
- |
| 8.1.2(Main Door- Outer & inner plate thickness) |
- |
15000 |
|
- |
| 8.1.2.1(Door(Finish &Gap of frame/edge with any place)) |
- |
15000 |
|
- |
| 8.2(Door frame (No.of barckets & Size for gripping)) |
- |
15000 |
|
- |
| 8.2.1(Rebate of the door frame) |
- |
15000 |
|
- |
| 8.2.2(Compression mechanism) |
- |
15000 |
|
- |
| 8.2.3(Crane hinge mechanism) |
- |
15000 |
|
- |
| 8.3(Lock case) |
- |
15000 |
|
- |
| 8.3.2(Bolt work) |
- |
15000 |
|
- |
| 8.3.2.2(Construction (of bolt work)) |
- |
15000 |
|
- |
| 8.3.2.3(Bearing piller) |
- |
15000 |
|
- |
| 8.4.1(Shooting bolt control (By lock)) |
- |
15000 |
|
- |
| 8.4.2(Test of key-Lock) |
- |
15000 |
|
- |
| 8.4.3(Lock fixing bolts) |
- |
15000 |
|
- |
| 8.4.4(Time lock) |
- |
15000 |
|
- |
| 8.4.5(Automatic Relocking devise) |
- |
15000 |
|
- |
| 9 &9.1(Hinges) |
- |
15000 |
|
- |
| 9.1.1(Adjusting bolt) |
- |
15000 |
|
- |
| 9.3(Foot bringe) |
- |
15000 |
|
- |
| 9.4(Vault lighting control) |
- |
15000 |
|
- |
| 10 &10.1(Dents,Burrs & Edges) |
- |
15000 |
|
- |
| 10.2(Colour coating thickness (Surafce paint)) |
- |
15000 |
|
- |
| 10.3(Cross Hatch test) |
- |
15000 |
|
- |
| 10.4(Door (Stainless cladding)) |
- |
15000 |
|
- |
| 11.1 &11.2(Test criteria for confomity -Burglaty attack) |
- |
15000 |
|
- |
| 11.1 &11.2(Test criteria for confomity -Fire resistancey) |
- |
15000 |
|
- |
| 12(Marking of door) |
- |
15000 |
|
- |
| 12.2(Marking on keys) |
- |
15000 |
|
- |
|
14 Nov, 2027 |
- Included w.e.f. 28.03.2025 |
| 7097 |
Atmy Analytical Labs Private Limited (Unit-2), Greater Noida
| 8176106
| IS 11188 : Part 1 (2021) |
Vault Strong Room doors Part 1 specification |
ALL |
349000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 11.1 (3)(Fire and stream hose IS 11188 (Part 3)) |
- |
349000 |
|
- |
| 11.1 (2)(Fire endurance IS 11188 (Part 3)) |
- |
349000 |
|
- |
| 11.1 (1)(Burglary resistance IS 11188 (Part 2)) |
- |
349000 |
|
- |
| 10.4(Alternate to Cl 10.4) |
- |
349000 |
|
- |
| 10.3(Cross Hatch Test) |
- |
349000 |
|
- |
| 10(FINISH) |
- |
349000 |
|
- |
| 9.4(Vault Lighting Control) |
- |
349000 |
|
- |
| 9.3(Foot Bridge) |
- |
349000 |
|
- |
| 9.2(Handles) |
- |
349000 |
|
- |
| 9.1.1(Adjusting Bolt) |
- |
349000 |
|
- |
| 9.1(Hinges) |
- |
349000 |
|
- |
| 9(DOOR FITTINGS) |
- |
349000 |
|
- |
| 8.4.5(Automatic Relocking Device) |
- |
349000 |
|
- |
| 8.4.4(Time Lock) |
- |
349000 |
|
- |
| 8.4(Lock) |
- |
349000 |
|
- |
| 8.3.2.2(Construction) |
- |
349000 |
|
- |
| 8.3.2.1(The number of bolts and their minimum dimension) |
- |
349000 |
|
- |
| 8.3.2(Bolt Work) |
- |
349000 |
|
- |
| 8.3.1(Lock Case) |
- |
349000 |
|
- |
| 8.3(Locking Mechanism) |
- |
349000 |
|
- |
| 8.2.3(Crane Hinge Mechanism) |
- |
349000 |
|
- |
| 8.2.2(Compression Mechanism) |
- |
349000 |
|
- |
| 8.2.1(Rebate of the Door Frame) |
- |
349000 |
|
- |
| 8.2(Doors Frame) |
- |
349000 |
|
- |
| 8.1.2(Main Door (Outside)) |
- |
349000 |
|
- |
| 8.1.1(Ventilating Grill Gate (Inside)) |
- |
349000 |
|
- |
| 8.1 Fig. 1(Doors) |
- |
349000 |
|
- |
| 8(CONSTRUCTION AND GENERALREQUIREMENTS) |
- |
349000 |
|
- |
| 5 Table 1(bolts, Min) |
- |
349000 |
|
- |
| 5 Table 1(xix) Depth of engagement of shooting) |
- |
349000 |
|
- |
| 5 Table 1(cross sectional area, Min,sq mm) |
- |
349000 |
|
- |
| 5 Table 1(xviii) Diameter of shooting bolts, Min) |
- |
349000 |
|
- |
| 5 Table 1(xvi) Number of shooting bolts at top,Min) |
- |
349000 |
|
- |
| 5 Table 1(xv) Number of shooting bolts on opposite side,Min) |
- |
349000 |
|
- |
| 5 Table 1(xiv) Number of shooting bolts on hinge side, Min) |
- |
349000 |
|
- |
| 5 Table 1(xiii) Number of locks) |
- |
349000 |
|
- |
| 5 Table 1(xii) Wall thickness (recommendation)) |
- |
349000 |
|
- |
| 5 Table 1(xi) Thickness of drill and oxyacetylene
torch resisting layer (excluding mild steel plates),Min) |
- |
349000 |
|
- |
| 5 Table 1(ix) Thickness of doors slab, thickness over rebate) |
- |
349000 |
|
- |
| 5 Table 1(viii) Pitch of grill gate rods) |
- |
349000 |
|
- |
| 5 Table 1(vii) Diameter of grill gate rods, Min) |
- |
349000 |
|
- |
| 5 Table 1(vi) Thickens of grill gate angles or
section made out of M.S. plates, Min) |
- |
349000 |
|
- |
| 5 Table 1(v) Dimension of the rebate coming under shear) |
- |
349000 |
|
- |
| 5 Table 1(iv (b) Thickness of door frame, if
fabricated from single plate to form
channel/multi-bend section, Min) |
- |
349000 |
|
- |
| 5 Table 1(ii (a) Height H, Min b) Width W, Min
iv(a) Thickness of door frame angle,
channel or section made out of M.S.
plates, if built up to form a channel,Min) |
- |
349000 |
|
- |
| 5 Table 1(iii) Inside dimension or clear opening when
door shutters are swung open at 180 degree) |
- |
349000 |
|
- |
| 5 Table 1(ii (b) Width W) |
- |
349000 |
|
- |
| 5 Table 1(ii (a) Height, H) |
- |
349000 |
|
- |
| 5 Table 1(ii) Overall dimension of vault door) |
- |
349000 |
|
- |
| 5 Table 1(i) Door Type) |
- |
349000 |
|
- |
| 4(Type) |
- |
349000 |
|
- |
| 5(Table-1)(Type of Door) |
- |
349000 |
|
- |
| 5(Table-1)(Overall dimesion of door) |
- |
349000 |
|
- |
| 5(Table-1)(Inside dimension or clear opening of door) |
- |
349000 |
|
- |
| 5(Table-1)(Thickness of door frame angle-made of Plate,if bulit up to form a channel) |
- |
349000 |
|
- |
| 5(Table-1)(Thickness of door frame ,if fabricated or multibend) |
- |
349000 |
|
- |
| 5(Table-1)(Dimension of the rebate coming under share) |
- |
349000 |
|
- |
| 5(Table-1)(Thickness of grill gate angle/section) |
- |
349000 |
|
- |
| 5(Table-1)(Diameter of grill gate rod) |
- |
349000 |
|
- |
| 5(Table-1)(Pitch of grill gate rod) |
- |
349000 |
|
- |
| 5(Table-1)(Thickness of door slab,thickness over rebate) |
- |
349000 |
|
- |
| 5(Table-1)(Thickness of the door over lock) |
- |
349000 |
|
- |
| 5(Table-1)(Thickness of drill & oxyacetylene torch resis. layer(exclue MS plate) |
- |
349000 |
|
- |
| 5(Table-1)(Wall thickness) |
- |
349000 |
|
- |
| 5(Table-1)(Number of locks) |
- |
349000 |
|
- |
| 5(Table-1)(Number of shooting bolys on hinge side) |
- |
349000 |
|
- |
| 5(Table-1)(Number of shooting bolts on opposite) |
- |
349000 |
|
- |
| 5(Table-1)(Number of shooting bolts at top) |
- |
349000 |
|
- |
| 5(Table-1)(Number of shooting bolts at bottom) |
- |
349000 |
|
- |
| 5(Table-1)(Cross sectional area as per shooting bolt) |
- |
349000 |
|
- |
| 5(Table-1)(Depth engagement of shooting) |
- |
349000 |
|
- |
| 6(Materail) |
- |
349000 |
|
- |
| 7(Classification) |
- |
349000 |
|
- |
| 8 & 8.1.1(Ventilating Grill Gate (Inside)) |
- |
349000 |
|
- |
| 8.1.1.1(Locking device (unpickable dual control lock)) |
- |
349000 |
|
- |
| 8.1.2(Main Door- Outer & inner plate thickness) |
- |
349000 |
|
- |
| 8.1.2.1(Door(Finish &Gap of frame/edge with any place)) |
- |
349000 |
|
- |
| 8.2(Door frame (No.of barckets & Size for gripping)) |
- |
349000 |
|
- |
| 8.2.1(Rebate of the door frame) |
- |
349000 |
|
- |
| 8.2.2(Compression mechanism) |
- |
349000 |
|
- |
| 8.2.3(Crane hinge mechanism) |
- |
349000 |
|
- |
| 8.3(Lock case) |
- |
349000 |
|
- |
| 8.3.2(Bolt work) |
- |
349000 |
|
- |
| 8.3.2.2(Construction (of bolt work)) |
- |
349000 |
|
- |
| 8.3.2.3(Bearing piller) |
- |
349000 |
|
- |
| 8.4.1(Shooting bolt control (By lock)) |
- |
349000 |
|
- |
| 8.4.2(Test of key-Lock) |
- |
349000 |
|
- |
| 8.4.3(Lock fixing bolts) |
- |
349000 |
|
- |
| 8.4.4(Time lock) |
- |
349000 |
|
- |
| 8.4.5(Automatic Relocking devise) |
- |
349000 |
|
- |
| 9 &9.1(Hinges) |
- |
349000 |
|
- |
| 9.1.1(Adjusting bolt) |
- |
349000 |
|
- |
| 9.2(Handles) |
- |
349000 |
|
- |
| 9.3(Foot bringe) |
- |
349000 |
|
- |
| 9.4(Vault lighting control) |
- |
349000 |
|
- |
| 10 &10.1(Dents,Burrs & Edges) |
- |
349000 |
|
- |
| 10.2(Colour coating thickness (Surafce paint)) |
- |
349000 |
|
- |
| 10.3(Cross Hatch test) |
- |
349000 |
|
- |
| 10.4(Door (Stainless cladding)) |
- |
349000 |
|
- |
| 11.1 &11.2(Test criteria for confomity -Burglaty attack) |
- |
349000 |
|
- |
| 11.1 &11.2(Test criteria for confomity -Fire resistancey) |
- |
349000 |
|
- |
| 12(Marking of door) |
- |
349000 |
|
- |
| 12.2(Marking on keys) |
- |
349000 |
|
- |
| 4(Type) |
- |
349000 |
|
- |
| 5(Table-1)(5(Table-1)) |
- |
349000 |
|
- |
| 5(Table-1)(Overall dimesion of door) |
- |
349000 |
|
- |
| 5(Table-1)(Inside dimension or clear opening of door) |
- |
349000 |
|
- |
| 5(Table-1)(Thickness of door frame angle-made of Plate,if bulit up to form a channel) |
- |
349000 |
|
- |
| 5(Table-1)(Thickness of door frame ,if fabricated or multibend) |
- |
349000 |
|
- |
| 5(Table-1)(Dimension of the rebate coming under share) |
- |
349000 |
|
- |
| 5(Table-1)(Thickness of grill gate angle/section) |
- |
349000 |
|
- |
| 5(Table-1)(Diameter of grill gate rod) |
- |
349000 |
|
- |
| 5(Table-1)(Pitch of grill gate rod) |
- |
349000 |
|
- |
| 5(Table-1)(Thickness of door slab,thickness over rebate) |
- |
349000 |
|
- |
| 5(Table-1)(Thickness of the door over lock) |
- |
349000 |
|
- |
| 5(Table-1)(Thickness of drill & oxyacetylene torch resis. layer(exclue MS plate) |
- |
349000 |
|
- |
| 5(Table-1)(Wall thickness) |
- |
349000 |
|
- |
| 5(Table-1)(Number of locks) |
- |
349000 |
|
- |
| 5(Table-1)(Number of shooting bolys on hinge side) |
- |
349000 |
|
- |
| 5(Table-1)(Number of shooting bolts at top) |
- |
349000 |
|
- |
| 5(Table-1)(Number of shooting bolts at bottom) |
- |
349000 |
|
- |
| 5(Table-1)(Cross sectional area as per shooting bolt) |
- |
349000 |
|
- |
| 5(Table-1)(Depth engagement of shooting) |
- |
349000 |
|
- |
| 6(Materail) |
- |
349000 |
|
- |
| 7(Classification) |
- |
349000 |
|
- |
| 8 & 8.1.1(Ventilating Grill Gate (Inside)) |
- |
349000 |
|
- |
| 8.1.1.1(Locking device (unpickable dual control lock)) |
- |
349000 |
|
- |
| 8.1.2(Main Door- Outer & inner plate thickness) |
- |
349000 |
|
- |
| 8.1.2.1(Door(Finish &Gap of frame/edge with any place)) |
- |
349000 |
|
- |
| 8.2(Door frame (No.of barckets & Size for gripping)) |
- |
349000 |
|
- |
| 8.2.1(Rebate of the door frame) |
- |
349000 |
|
- |
| 8.2.2(Compression mechanism) |
- |
349000 |
|
- |
| 8.2.3(Crane hinge mechanism) |
- |
349000 |
|
- |
| 8.3(Lock case) |
- |
349000 |
|
- |
| 8.3.2(Bolt work) |
- |
349000 |
|
- |
| 8.3.2.2(Construction (of bolt work)) |
- |
349000 |
|
- |
| 8.3.2.3(Bearing piller) |
- |
349000 |
|
- |
| 8.4.1(Shooting bolt control (By lock)) |
- |
349000 |
|
- |
| 8.4.2(Test of key-Lock) |
- |
349000 |
|
- |
| 8.4.3(Lock fixing bolts) |
- |
349000 |
|
- |
| 8.4.4(Time lock) |
- |
349000 |
|
- |
| 8.4.5(Automatic Relocking devise) |
- |
349000 |
|
- |
| 9 &9.1(Hinges) |
- |
349000 |
|
- |
| 9.1.1(Adjusting bolt) |
- |
349000 |
|
- |
| 9.3(Foot bringe) |
- |
349000 |
|
- |
| 9.4(Vault lighting control) |
- |
349000 |
|
- |
| 10 &10.1(Dents,Burrs & Edges) |
- |
349000 |
|
- |
| 10.2(Colour coating thickness (Surafce paint)) |
- |
349000 |
|
- |
| 10.3(Cross Hatch test) |
- |
349000 |
|
- |
| 10.4(Door (Stainless cladding)) |
- |
349000 |
|
- |
| 11.1 &11.2(Test criteria for confomity -Burglaty attack) |
- |
349000 |
|
- |
| 11.1 &11.2(Test criteria for confomity -Fire resistancey) |
- |
349000 |
|
- |
| 12(Marking of door) |
- |
349000 |
|
- |
| 12.2(Marking on keys) |
- |
349000 |
|
- |
|
08 Feb, 2027 |
- Included w.e.f. 01.04.2025 |
| 7098 |
Atmy Analytical Labs Private Limited (Unit-2), Greater Noida
| 8176106
| IS 5244 (2020) |
Safe Deposit Locker Cabinets — Specification ( Fourth Revision ) |
- |
39500 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl. 4.1( Types ) |
- |
0 |
|
- |
| Cl. 6 (Fig-5)(Cabinet Size (in mm)) |
- |
0 |
|
- |
| Table 1(Thickness Min. (in mm)) |
- |
0 |
|
- |
| Table 1(Thickness Min. (in mm)) |
- |
0 |
|
- |
| Table 1(Thickness Min. (in mm)) |
- |
0 |
|
- |
| Table 1(Thickness Min. (in mm)) |
- |
0 |
|
- |
| Table 1(Thickness Min. (in mm)) |
- |
0 |
|
- |
| Table 1(Thickness Min. (in mm)) |
- |
0 |
|
- |
| Table 1(Thickness Min. (in mm)) |
- |
0 |
|
- |
| Table 1(Thickness Min. (in mm)) |
- |
0 |
|
- |
| Table 1(Thickness Min. (in mm)) |
- |
0 |
|
- |
| Table 1(Thickness Min. (in mm)) |
- |
0 |
|
- |
| Table 1(Finish) |
- |
0 |
|
- |
| Table 1(Finish) |
- |
0 |
|
- |
| Cl.6(Sizes (Minimum Inside Measurements of locker) Locker Size) |
- |
0 |
|
- |
| Cl.6(Sizes (Minimum Inside Measurements of locker) Locker Size) |
- |
0 |
|
- |
| Cl.6(Sizes (Minimum Inside Measurements of locker) Locker Size) |
- |
0 |
|
- |
| Cl. 7.1(Design and Manufacture) |
- |
0 |
|
- |
| Cl. 7.1(Design and Manufacture) |
- |
0 |
|
- |
| Cl. 7.1(Design and Manufacture) |
- |
0 |
|
- |
| Cl. 7.1(Design and Manufacture) |
- |
0 |
|
- |
| Cl. 7.1(Design and Manufacture) |
- |
0 |
|
- |
| Cl. 7.2(Design and Manufacture) |
- |
0 |
|
- |
| Cl. 7.3(Design and Manufacture) |
- |
0 |
|
- |
| Cl. 7.3(Design and Manufacture) |
- |
0 |
|
- |
| Cl. 7.4(Design and Manufacture) |
- |
0 |
|
- |
| Cl. 7.5(Design and Manufacture) |
- |
0 |
|
- |
| Cl. 7.6(Design and Manufacture) |
- |
0 |
|
- |
| Cl. 8(Workmanship) |
- |
0 |
|
- |
| Cl. 8.2(Tolerance) |
- |
0 |
|
- |
| Cl. 9.1(Testing) |
- |
0 |
|
- |
| Cl. 9.2(Testing) |
- |
0 |
|
- |
| Cl. 9.3(Cross Hatch Test) |
- |
0 |
|
- |
| Cl. 10.1(Marking) |
- |
0 |
|
- |
| Cl. 10.2(Marking) |
- |
0 |
|
- |
| Cl. 10.3(Marking) |
- |
0 |
|
- |
| Cl. 10.4(Marking on Keys) |
- |
0 |
|
- |
| Cl. 11(Packing) |
- |
0 |
|
- |
|
08 Feb, 2027 |
- Included w.e.f. 01.04.2025 |
| 7099 |
URS PRODUCTS AND TESTING PVT. LTD. (A29), NOIDA
| 8168906
| IS 2347 (2017) |
Domestic pressure cooker - Specification (Sixth Revision) |
- |
34000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4.1(Capacity) |
- |
400 |
|
- |
| 5.1.1(Body, Lid, Containers and Grid) |
- |
300 |
|
- |
| 5.1.2(Body, Lid, Containers and Grid) |
- |
300 |
|
- |
| 5.1.3(Body, Lid, Containers and Grid) |
- |
300 |
|
- |
| 5.1.4(Body, Lid, Containers and Grid) |
- |
300 |
|
- |
| 5.2(Safety Relief Device) |
- |
300 |
|
- |
| 5.3(Gasket) |
- |
300 |
|
- |
| 5.4(Handles and Knobs) |
- |
300 |
|
- |
| 5.5(Pressure Regulating Device) |
- |
300 |
|
- |
| 5.6(Vent Seal Pin for Pressure Regulating Device) |
- |
300 |
|
- |
| 5.7(Vent Pipe) |
- |
300 |
|
- |
| 5.8(Vent Pipe Nut) |
- |
300 |
|
- |
| 5.9(Spring) |
- |
300 |
|
- |
| 6(CONSTRUCTION) |
- |
300 |
|
- |
| 6.1(Pressure Regulating Device) |
- |
300 |
|
- |
| 6.1.1(Pressure Regulating Device) |
- |
300 |
|
- |
| 6.1.2(Pressure Regulating Device) |
- |
300 |
|
- |
| 6.1.3(Pressure Regulating Device) |
- |
300 |
|
- |
| 6.1.4(Pressure Regulating Device) |
- |
300 |
|
- |
| 6.1.5(Pressure Regulating Device) |
- |
300 |
|
- |
| 6.2(Safety Relief Device) |
- |
300 |
|
- |
| 6.2.1(Safety Relief Device) |
- |
300 |
|
- |
| 6.2.2(Safety Relief Device) |
- |
300 |
|
- |
| 6.3.1(Temperature Responsive Pressure Relief Device) |
- |
400 |
|
- |
| 6.3.1(Temperature Responsive Pressure Relief Device) |
- |
4000 |
|
- |
| 6.4.1(Handles and Knobs) |
- |
300 |
|
- |
| 6.4.1.1(Handles and Knobs) |
- |
300 |
|
- |
| 7.1(WORKMANSHIP AND FINISH) |
- |
300 |
|
- |
| 7.2(WORKMANSHIP AND FINISH) |
- |
300 |
|
- |
| 7.3(WORKMANSHIP AND FINISH) |
- |
500 |
|
- |
| 7.4(WORKMANSHIP AND FINISH) |
- |
1000 |
|
- |
| 8.1(Air Pressure Test) |
- |
600 |
|
- |
| 8.2(Proof Pressure Test) |
- |
600 |
|
- |
| 8.3(Operating Test for Pressure Regulating Device) |
- |
800 |
|
- |
| 8.4(Test for Safety Pressure Relief Device) |
- |
800 |
|
- |
| 8.5(Bursting Pressure Test) |
- |
1000 |
|
- |
| 8.6.1(Tests for Removal of Lid under Pressure For Outer Lid Cooker) |
- |
900 |
|
- |
| 8.6.2(Tests for Removal of Lid under Pressure For inner Lid Cooker) |
- |
900 |
|
- |
| 8.7(Test for Spring Loaded Mechanism) |
- |
800 |
|
- |
| 8.8(Test for Spring Loaded Mechanism) |
- |
1200 |
|
- |
| 8.9(Test for Spring Loaded Mechanism) |
- |
1200 |
|
- |
| 8.1(testing of handles of the cooker) |
- |
1200 |
|
- |
| 8.4 Annex H-1.2(Test for SPRD - For Resettable Devices ) |
- |
800 |
|
- |
| 8.4 Annex H-1.1(Test for SPRD - For Destructible Devices ) |
- |
800 |
|
- |
| 8.10 (a)(Handles of the cooker- Resistance to Burning) |
- |
700 |
|
- |
| 8.10 (b)(Handles of the cooker- Heat Resistance) |
- |
700 |
|
- |
| 8.10 (c)(Handles of the cooker- Torque Strength) |
- |
700 |
|
- |
| 8.10 (d)(Handles of the cooker- Bending Strength) |
- |
700 |
|
- |
| 8.10 (e)(Handles of the cooker- Fatigue Resistance) |
- |
1200 |
|
- |
| 8.10 (f)(Handles of the cooker- Thermal Insualtion Test) |
- |
800 |
|
- |
| 8.10 NOTES (3)(Handles of the cooker - Proof Pressure) |
- |
300 |
|
- |
| 8.10 NOTES (4)(Handles of the cooker) |
- |
300 |
|
- |
| 8.10 NOTES (5)(Handles of the cooker) |
- |
300 |
|
- |
| 8.10 NOTES (6)(Handles of the cooker) |
- |
300 |
|
- |
| 8.11.1 (a)(External Coating (powder coating or ceramic coating or high temperature resistant liquid coating)) |
- |
800 |
|
- |
| 8.11.1 (b)(External Coating (powder coating or ceramic coating or high temperature resistant liquid coating)) |
- |
800 |
|
- |
| 8.11.1 (c)(External Coating (powder coating or ceramic coating or high temperature resistant liquid coating)) |
- |
800 |
|
- |
| 8.11.1.1 (Thermal shock test for externally coated cooker) |
- |
1200 |
|
- |
| 8.12(Internal Coating) |
- |
1300 |
|
- |
| 8.14(3 Ply Construction Cooker Body) |
- |
1000 |
|
- |
| 11(Marking) |
- |
300 |
|
- |
|
- |
- - |
| 7100 |
URS PRODUCTS AND TESTING PVT. LTD. (A29), NOIDA
| 8168906
| IS 14756 (2022) |
Draft Indian Standard STAINLESS STEEL COOKWARE SPECIFICATION Second Revision of IS 14756 |
- |
12000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 3.1(Material) |
- |
500 |
|
- |
| 3.2(Material) |
- |
500 |
|
- |
| 3.3(Material) |
- |
500 |
|
- |
| 3.4(Material) |
- |
500 |
|
- |
| 3.5(Material) |
- |
500 |
|
- |
| 4.1 (Annex A)(Shapes and Dimensions) |
- |
500 |
|
- |
| 4.2 (Table 1)(Shapes and Dimensions) |
- |
500 |
|
- |
| 4.3(Shapes and Dimensions) |
- |
500 |
|
- |
| 4.4(Shapes and Dimensions) |
- |
500 |
|
- |
| 6.1(Staining Test) |
- |
1000 |
|
- |
| 6.2(Mechanical Shock Test (For Cladded Utensils only)) |
- |
1000 |
|
- |
| 6.3(Thermal Shock Test (For Cladded Utensils only)) |
- |
1000 |
|
- |
| 6.4(Dry Heat Test (For Cladded Utensils only)) |
- |
1500 |
|
- |
| 6.5(Coating Thickness Test (For Copper Deposit)) |
- |
1000 |
|
- |
| 6.6(3 Ply) |
- |
1000 |
|
- |
| 6.7.1(Nominal Capacity Test) |
- |
1000 |
|
- |
| 6.8.1(Tests on Tempered Glass Lid) |
- |
1000 |
|
- |
| 6.8.2(Tests on Tempered Glass Lid (Ball drop test)) |
- |
1000 |
|
- |
| 6.8.3(Tests on Tempered Glass Lid (thermal shock test)) |
- |
1000 |
|
- |
| 6.8.4.1(Tests on Tempered Glass Lid (Free Fall Test with rim facing down)) |
- |
1000 |
|
- |
| 6.8.4.2(Tests on Tempered Glass Lid (Free Fall Test without rim facing down)) |
- |
1000 |
|
- |
| 3.4(Material) |
- |
500 |
|
- |
| 3.5(Material) |
- |
500 |
|
- |
| 3.5(Material) |
- |
500 |
|
- |
| 3.5(Material) |
- |
500 |
|
- |
| 4.2 (Table 1)(Shapes and Dimensions) |
- |
500 |
|
- |
| 4.2(Shapes and Dimensions) |
- |
500 |
|
- |
| 5.1(Workmanship and Finish) |
- |
500 |
|
- |
| 5.1(Workmanship and Finish) |
- |
500 |
|
- |
| 5.1(Workmanship and Finish) |
- |
500 |
|
- |
| 5.2(Workmanship and Finish) |
- |
500 |
|
- |
| 5.3(Workmanship and Finish) |
- |
500 |
|
- |
| 5.3(Workmanship and Finish) |
- |
500 |
|
- |
| 5.3(Workmanship and Finish) |
- |
500 |
|
- |
| 5.3(Workmanship and Finish) |
- |
500 |
|
- |
| 5.3(Workmanship and Finish) |
- |
500 |
|
- |
| 5.3(Workmanship and Finish) |
- |
500 |
|
- |
| 5.4(Workmanship and Finish) |
- |
500 |
|
- |
| 5.5(Workmanship and Finish) |
- |
500 |
|
- |
| 5.6(Workmanship and Finish) |
- |
500 |
|
- |
| 6.1(Staining Test) |
- |
1000 |
|
- |
| 6.7.2(Nominal Capacity Test- Diameter) |
- |
1000 |
|
- |
| 6.8.1(Tests on Tempered Glass Lid) |
- |
1000 |
|
- |
|
- |
- - |
| 7101 |
Ace Test Labs & Metrology Pvt. Ltd., Sonipat
| 9162826
| IS 550 : Part 1 (2022) |
Safes: Part 1 specification Fifth Revision |
- |
258000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4(Classification) |
- |
124999.97 |
|
- |
| 5.1(Dimensions) |
- |
10000 |
|
- |
| 5.2(Sizes) |
- |
10000 |
|
- |
| 5.2(Table-2)(Inside dimensions) |
- |
10000 |
|
- |
| 5.2(Table-2)(Tolerance on inside dimensions) |
- |
10000 |
|
- |
| 5.2(Table-2)(Internal volume) |
- |
10000 |
|
- |
| 5.2(Table-2)(Tolerance on interanal volume) |
- |
10000 |
|
- |
| 5.2(Table-2)(Minumum Weight) |
- |
10000 |
|
- |
| 5.2(Table-2)(Thickness of Plates (outer bodys& Door)) |
- |
10000 |
|
- |
| 5.2(Table-2)(Thickness of Door slab) |
- |
10000 |
|
- |
| 5.2(Table-2)(Thickness of door overbolt work) |
- |
10000 |
|
- |
| 5.2(Table-2)(Number of lock on the door) |
- |
10000 |
|
- |
| 5.2(Table-2)(Any other type of lock) |
- |
10000 |
|
- |
| 5.2(Table-2)(Number of bolt on hinge side) |
- |
10000 |
|
- |
| 5.2(Table-2)(Number of bolt on opposite hinge) |
- |
10000 |
|
- |
| 5.2(Table-2)(No.of bolt at the top) |
- |
10000 |
|
- |
| 5.2(Table-2)(No.of bolt at the bottom) |
- |
10000 |
|
- |
| 5.2(Table-2)(Size of each bolt (area of bolt section)) |
- |
10000 |
|
- |
| 5.2(Table-2)(Depth engagement of bolt) |
- |
10000 |
|
- |
| 6(Material declaration) |
- |
10000 |
|
- |
| 7(Desigantion-Delaration) |
- |
10000 |
|
- |
| 8.1(Body (Construction & workmanship)) |
- |
10000 |
|
- |
| 8.2(Door (Gap)) |
- |
10000 |
|
- |
| 8.4.1(Hinges) |
- |
10000 |
|
- |
| 8.4.2(Bolts) |
- |
10000 |
|
- |
| 8.5(Handle) |
- |
10000 |
|
- |
| 8.6.1(Lock (key type) Garde) |
- |
10000 |
|
- |
| 8.6.1(Lock (key type)classification) |
- |
10000 |
|
- |
| 8.6.1(Lock (key type)construction) |
- |
10000 |
|
- |
| 8.6.1(Lock(key type) leaver thickness) |
- |
10000 |
|
- |
| 8.6.1(Lock (key type)Material) |
- |
10000 |
|
- |
| 8.6.1(Lock (key type)corrosion protection materail) |
- |
10000 |
|
- |
| 8.6.1(Lock(key type) -Endurance test) |
- |
10000 |
|
- |
| 8.6.1(Lock(key type)-Bolt forcing test) |
- |
10000 |
|
- |
| 8.6.1(Lock(key type)-salt spray solution test) |
- |
10000 |
|
- |
| 8.6.1(Lock(key type)-key strength test) |
- |
10000 |
|
- |
| 8.6.1(Lock(key type) -Marking) |
- |
10000 |
|
- |
| 8.6.1(Lock(Key type) -Key Marking) |
- |
10000 |
|
- |
| 8.6.1(Mechanical combination lock -Classification) |
- |
10000 |
|
- |
| 8.6.1(Mechanical combination lock -Construction) |
- |
10000 |
|
- |
| 8.6.1(Mechanical combination lock -Metallic parts) |
- |
10000 |
|
- |
| 8.6.1(Mechanical combination lock -Corrosion Prot) |
- |
10000 |
|
- |
| 8.6.1(Mechanical combination lock -Operation test) |
- |
10000 |
|
- |
| 8.6.1(Mechanical cmbination lock -Manipulation) |
- |
10000 |
|
- |
| 8.6.1(Mechanical combination lock -Punching attack) |
- |
10000 |
|
- |
| 8.6.1(Mechanical combination lock -Endurance test) |
- |
10000 |
|
- |
| 8.6.1(Mechanical combination lock-Salt spary test) |
- |
10000 |
|
- |
| 8.6.1(Mechanical combination lock-Strength test) |
- |
10000 |
|
- |
| 8.6.1(Mechanical combination lock-Aging-stress Dist) |
- |
10000 |
|
- |
| 8.6.1(Mechanical combination lock-Moisture Absorp) |
- |
10000 |
|
- |
| 8.6.1(Mechanical combination lock-Vibration test) |
- |
10000 |
|
- |
| 8.6.1(Mechanical combination lock-Marking) |
- |
10000 |
|
- |
| 8.6.1(Any other lock) |
- |
10000 |
|
- |
| 8.6.4(Lock Bolt engagement) |
- |
10000 |
|
- |
| 8.6.5(Additional provision- retrofitting time lock) |
- |
10000 |
|
- |
| 8.7(Automatic re-locking device) |
- |
10000 |
|
- |
| 8.8(Cable hole size) |
- |
10000 |
|
- |
| 9(Internal fixture) |
- |
10000 |
|
- |
| 10(Painting) |
- |
10000 |
|
- |
| 10.1(Cross hatch test) |
- |
10000 |
|
- |
| 11.1(Marking of safe) |
- |
10000 |
|
- |
| 12(Burglary attack) |
- |
99999.97 |
|
- |
| 12(Fire Resistance) |
- |
150000 |
|
- |
| 4(Classification) |
- |
100000 |
|
- |
| 5.1(Dimensions) |
- |
10000 |
|
- |
| 5.2(Sizes) |
- |
10000 |
|
- |
| 5.2(Table-2)(Inside dimensions) |
- |
10000 |
|
- |
| 5.2(Table-2)(Tolerance on inside dimensions) |
- |
10000 |
|
- |
| 5.2(Table-2)(Internal volume) |
- |
10000 |
|
- |
| 5.2(Table-2)(Tolerance on interanal volume) |
- |
10000 |
|
- |
| 5.2(Table-2)(Minumum Weight) |
- |
10000 |
|
- |
| 5.2(Table-2)(Thickness of Plates (outer bodys& Door)) |
- |
10000 |
|
- |
| 5.2(Table-2)(Thickness of Door slab) |
- |
10000 |
|
- |
| 5.2(Table-2)(Thickness of door overbolt work) |
- |
10000 |
|
- |
| 5.2(Table-2)(Number of lock on the door) |
- |
10000 |
|
- |
| 5.2(Table-2)(Any other type of lock) |
- |
10000 |
|
- |
| 5.2(Table-2)(Number of bolt on hinge side) |
- |
10000 |
|
- |
| 5.2(Table-2)(Number of bolt on opposite hinge) |
- |
10000 |
|
- |
| 5.2(Table-2)(No.of bolt at the top) |
- |
10000 |
|
- |
| 5.2(Table-2)(No.of bolt at the bottom) |
- |
10000 |
|
- |
| 5.2(Table-2)(Size of each bolt (area of bolt section)) |
- |
10000 |
|
- |
| 5.2(Table-2)(Depth engagement of bolt) |
- |
10000 |
|
- |
| 6(Material declaration) |
- |
10000 |
|
- |
| 7(Desigantion-Delaration) |
- |
10000 |
|
- |
| 8.1(Body (Construction & workmanship)) |
- |
10000 |
|
- |
| 8.2(Door (Gap)) |
- |
10000 |
|
- |
| 8.4.1(Hinges) |
- |
10000 |
|
- |
| 8.4.2(Bolts) |
- |
10000 |
|
- |
| 8.5(Handle) |
- |
10000 |
|
- |
| 8.6.1(Lock (key type) Garde) |
- |
10000 |
|
- |
| 8.6.1(Lock (key type)classification) |
- |
10000 |
|
- |
| 8.6.1(Lock (key type)construction) |
- |
10000 |
|
- |
| 8.6.1(Lock(key type) leaver thickness) |
- |
10000 |
|
- |
| 8.6.1(Lock (key type)Material) |
- |
10000 |
|
- |
| 8.6.1(Lock (key type)corrosion protection materail) |
- |
10000 |
|
- |
| 8.6.1(Lock(key type) -Endurance test) |
- |
10000 |
|
- |
| 8.6.1(Lock(key type)-Bolt forcing test) |
- |
10000 |
|
- |
| 8.6.1(Lock(key type)-salt spray solution test) |
- |
10000 |
|
- |
| 8.6.1(Lock(key type)-key strength test) |
- |
10000 |
|
- |
| 8.6.1(Lock(key type) -Marking) |
- |
10000 |
|
- |
| 8.6.1(Lock(Key type) -Key Marking) |
- |
10000 |
|
- |
| 8.6.1(Mechanical combination lock -Classification) |
- |
10000 |
|
- |
| 8.6.1(Mechanical combination lock -Construction) |
- |
10000 |
|
- |
| 8.6.1(Mechanical combination lock -Metallic parts) |
- |
10000 |
|
- |
| 8.6.1(Mechanical combination lock -Corrosion Prot) |
- |
10000 |
|
- |
| 8.6.1(Mechanical combination lock -Operation test) |
- |
10000 |
|
- |
| 8.6.1(Mechanical cmbination lock -Manipulation) |
- |
10000 |
|
- |
| 8.6.1(Mechanical combination lock -Punching attack) |
- |
10000 |
|
- |
| 8.6.1(Mechanical combination lock -Endurance test) |
- |
10000 |
|
- |
| 8.6.1(Mechanical combination lock-Salt spary test) |
- |
10000 |
|
- |
| 8.6.1(Mechanical combination lock-Strength test) |
- |
10000 |
|
- |
| 8.6.1(Mechanical combination lock-Aging-stress Dist) |
- |
10000 |
|
- |
| 8.6.1(Mechanical combination lock-Moisture Absorp) |
- |
10000 |
|
- |
| 8.6.1(Mechanical combination lock-Vibration test) |
- |
10000 |
|
- |
| 8.6.1(Mechanical combination lock-Marking) |
- |
10000 |
|
- |
| 8.6.1(Any other lock) |
- |
10000 |
|
- |
| 8.6.4(Lock Bolt engagement) |
- |
10000 |
|
- |
| 8.6.5(Additional provision- retrofitting time lock) |
- |
10000 |
|
- |
| 8.7(Automatic re-locking device) |
- |
10000 |
|
- |
| 8.8(Cable hole size) |
- |
10000 |
|
- |
| 9(Internal fixture) |
- |
10000 |
|
- |
| 10(Painting) |
- |
10000 |
|
- |
| 10.1(Cross hatch test) |
- |
10000 |
|
- |
| 11.1(Marking of safe) |
- |
10000 |
|
- |
| 12(Burglary attack) |
- |
100000 |
|
- |
| 12(Fire Resistance) |
- |
150000 |
|
- |
|
14 Nov, 2027 |
- Included w.e.f. 28.03.2025 |
| 7102 |
Atmy Analytical Labs Private Limited (Unit-2), Greater Noida
| 8176106
| IS 17541 (2021) |
Modular panel for security of premises specification |
- |
546000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Clause-5(Dimensions) |
- |
0 |
|
- |
| Clause-6(Materials) |
- |
0 |
|
- |
| Clause-8(Construction and General Requirements) |
- |
0 |
|
- |
| Clause-9(Fittings) |
- |
0 |
|
- |
| Clause-10(Finish) |
- |
0 |
|
- |
| Clause-10.1(Cross Hatch Test) |
- |
0 |
|
- |
| Clause-11.2, 1(Full length panel (Continuous design panel)) |
- |
0 |
|
- |
| Clause-11.2, 2(Assemble panel/Segmented panel) |
- |
0 |
|
- |
| Clause-12(Marking) |
- |
0 |
|
- |
| Clause-5(Dimensions) |
- |
0 |
|
- |
| Clause-6(Materials) |
- |
0 |
|
- |
| Clause-8(Construction and General Requirements) |
- |
0 |
|
- |
| Clause-9(Fittings) |
- |
0 |
|
- |
| Clause-10(Finish) |
- |
0 |
|
- |
| Clause-10.1(Cross Hatch Test) |
- |
0 |
|
- |
| Clause-11.2, 1(Full length panel (Continuous design panel)) |
- |
0 |
|
- |
| Clause-11.2, 2(Assemble panel/Segmented panel) |
- |
0 |
|
- |
| Clause-12(Marking) |
- |
0 |
|
- |
|
08 Feb, 2027 |
- Included w.e.f. 01.04.2025 |
| 7103 |
Atmy Analytical Labs Private Limited (Unit-2), Greater Noida
| 8176106
| IS 550 : Part 1 (2022) |
Safes: Part 1 specification Fifth Revision |
- |
380000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4(Classification) |
- |
0 |
|
- |
| 5.1(Dimensions) |
- |
0 |
|
- |
| 5.2(Sizes) |
- |
0 |
|
- |
| 5.2(Table-2)(Inside dimensions) |
- |
0 |
|
- |
| 5.2(Table-2)(Tolerance on inside dimensions) |
- |
0 |
|
- |
| 5.2(Table-2)(Internal volume) |
- |
0 |
|
- |
| 5.2(Table-2)(Tolerance on interanal volume) |
- |
0 |
|
- |
| 5.2(Table-2)(Minumum Weight) |
- |
0 |
|
- |
| 5.2(Table-2)(Thickness of Plates (outer bodys& Door)) |
- |
0 |
|
- |
| 5.2(Table-2)(Thickness of Door slab) |
- |
0 |
|
- |
| 5.2(Table-2)(Thickness of door overbolt work) |
- |
0 |
|
- |
| 5.2(Table-2)(Number of lock on the door) |
- |
0 |
|
- |
| 5.2(Table-2)(Any other type of lock) |
- |
0 |
|
- |
| 5.2(Table-2)(Number of bolt on hinge side) |
- |
0 |
|
- |
| 5.2(Table-2)(Number of bolt on opposite hinge) |
- |
0 |
|
- |
| 5.2(Table-2)(No.of bolt at the top) |
- |
0 |
|
- |
| 5.2(Table-2)(No.of bolt at the bottom) |
- |
0 |
|
- |
| 5.2(Table-2)(Size of each bolt (area of bolt section)) |
- |
0 |
|
- |
| 5.2(Table-2)(Depth engagement of bolt) |
- |
0 |
|
- |
| 6(Material declaration) |
- |
0 |
|
- |
| 7(Desigantion-Delaration) |
- |
0 |
|
- |
| 8.1(Body (Construction & workmanship)) |
- |
0 |
|
- |
| 8.2(Door (Gap)) |
- |
0 |
|
- |
| 8.4.1(Hinges) |
- |
0 |
|
- |
| 8.4.2(Bolts) |
- |
0 |
|
- |
| 8.5(Handle) |
- |
0 |
|
- |
| 8.6.1(Lock (key type) Garde) |
- |
0 |
|
- |
| 8.6.1(Lock (key type)classification) |
- |
0 |
|
- |
| 8.6.1(Lock (key type)construction) |
- |
0 |
|
- |
| 8.6.1(Lock(key type) leaver thickness) |
- |
0 |
|
- |
| 8.6.1(Lock (key type)Material) |
- |
0 |
|
- |
| 8.6.1(Lock (key type)corrosion protection materail) |
- |
0 |
|
- |
| 8.6.1(Lock(key type) -Endurance test) |
- |
0 |
|
- |
| 8.6.1(Lock(key type)-Bolt forcing test) |
- |
0 |
|
- |
| 8.6.1(Lock(key type)-salt spray solution test) |
- |
0 |
|
- |
| 8.6.1(Lock(key type)-key strength test) |
- |
0 |
|
- |
| 8.6.1(Lock(key type) -Marking) |
- |
0 |
|
- |
| 8.6.1(Lock(Key type) -Key Marking) |
- |
0 |
|
- |
| 8.6.1(Mechanical combination lock -Classification) |
- |
0 |
|
- |
| 8.6.1(Mechanical combination lock -Construction) |
- |
0 |
|
- |
| 8.6.1(Mechanical combination lock -Metallic parts) |
- |
0 |
|
- |
| 8.6.1(Mechanical combination lock -Corrosion Prot) |
- |
0 |
|
- |
| 8.6.1(Mechanical combination lock -Operation test) |
- |
0 |
|
- |
| 8.6.1(Mechanical cmbination lock -Manipulation) |
- |
0 |
|
- |
| 8.6.1(Mechanical combination lock -Punching attack) |
- |
0 |
|
- |
| 8.6.1(Mechanical combination lock -Endurance test) |
- |
0 |
|
- |
| 8.6.1(Mechanical combination lock-Salt spary test) |
- |
0 |
|
- |
| 8.6.1(Mechanical combination lock-Strength test) |
- |
0 |
|
- |
| 8.6.1(Mechanical combination lock-Aging-stress Dist) |
- |
0 |
|
- |
| 8.6.1(Mechanical combination lock-Moisture Absorp) |
- |
0 |
|
- |
| 8.6.1(Mechanical combination lock-Vibration test) |
- |
0 |
|
- |
| 8.6.1(Mechanical combination lock-Marking) |
- |
0 |
|
- |
| 8.6.1(Any other lock) |
- |
0 |
|
- |
| 8.6.4(Lock Bolt engagement) |
- |
0 |
|
- |
| 8.6.5(Additional provision- retrofitting time lock) |
- |
0 |
|
- |
| 8.7(Automatic re-locking device) |
- |
0 |
|
- |
| 8.8(Cable hole size) |
- |
0 |
|
- |
| 9(Internal fixture) |
- |
0 |
|
- |
| 10(Painting) |
- |
0 |
|
- |
| 10.1(Cross hatch test) |
- |
0 |
|
- |
| 11.1(Marking of safe) |
- |
0 |
|
- |
| 12(Burglary attack) |
- |
0 |
|
- |
| 12(Fire Resistance) |
- |
0 |
|
- |
| 4(Classification) |
- |
0 |
|
- |
| 5.1(Dimensions) |
- |
0 |
|
- |
| 5.2(Sizes) |
- |
0 |
|
- |
| 5.2(Table-2)(Inside dimensions) |
- |
0 |
|
- |
| 5.2(Table-2)(Tolerance on inside dimensions) |
- |
0 |
|
- |
| 5.2(Table-2)(Internal volume) |
- |
0 |
|
- |
| 5.2(Table-2)(Tolerance on interanal volume) |
- |
0 |
|
- |
| 5.2(Table-2)(Minumum Weight) |
- |
0 |
|
- |
| 5.2(Table-2)(Thickness of Plates (outer bodys& Door)) |
- |
0 |
|
- |
| 5.2(Table-2)(Thickness of Door slab) |
- |
0 |
|
- |
| 5.2(Table-2)(Thickness of door overbolt work) |
- |
0 |
|
- |
| 5.2(Table-2)(Number of lock on the door) |
- |
0 |
|
- |
| 5.2(Table-2)(Any other type of lock) |
- |
0 |
|
- |
| 5.2(Table-2)(Number of bolt on hinge side) |
- |
0 |
|
- |
| 5.2(Table-2)(Number of bolt on opposite hinge) |
- |
0 |
|
- |
| 5.2(Table-2)(No.of bolt at the top) |
- |
0 |
|
- |
| 5.2(Table-2)(No.of bolt at the bottom) |
- |
0 |
|
- |
| 5.2(Table-2)(Size of each bolt (area of bolt section)) |
- |
0 |
|
- |
| 5.2(Table-2)(Depth engagement of bolt) |
- |
0 |
|
- |
| 6(Material declaration) |
- |
0 |
|
- |
| 7(Desigantion-Delaration) |
- |
0 |
|
- |
| 8.1(Body (Construction & workmanship)) |
- |
0 |
|
- |
| 8.2(Door (Gap)) |
- |
0 |
|
- |
| 8.4.1(Hinges) |
- |
0 |
|
- |
| 8.4.2(Bolts) |
- |
0 |
|
- |
| 8.5(Handle) |
- |
0 |
|
- |
| 8.6.1(Lock (key type) Garde) |
- |
0 |
|
- |
| 8.6.1(Lock (key type)classification) |
- |
0 |
|
- |
| 8.6.1(Lock (key type)construction) |
- |
0 |
|
- |
| 8.6.1(Lock(key type) leaver thickness) |
- |
0 |
|
- |
| 8.6.1(Lock (key type)Material) |
- |
0 |
|
- |
| 8.6.1(Lock (key type)corrosion protection materail) |
- |
0 |
|
- |
| 8.6.1(Lock(key type) -Endurance test) |
- |
0 |
|
- |
| 8.6.1(Lock(key type)-Bolt forcing test) |
- |
0 |
|
- |
| 8.6.1(Lock(key type)-salt spray solution test) |
- |
0 |
|
- |
| 8.6.1(Lock(key type)-key strength test) |
- |
0 |
|
- |
| 8.6.1(Lock(key type) -Marking) |
- |
0 |
|
- |
| 8.6.1(Lock(Key type) -Key Marking) |
- |
0 |
|
- |
| 8.6.1(Mechanical combination lock -Classification) |
- |
0 |
|
- |
| 8.6.1(Mechanical combination lock -Construction) |
- |
0 |
|
- |
| 8.6.1(Mechanical combination lock -Metallic parts) |
- |
0 |
|
- |
| 8.6.1(Mechanical combination lock -Corrosion Prot) |
- |
0 |
|
- |
| 8.6.1(Mechanical combination lock -Operation test) |
- |
0 |
|
- |
| 8.6.1(Mechanical cmbination lock -Manipulation) |
- |
0 |
|
- |
| 8.6.1(Mechanical combination lock -Punching attack) |
- |
0 |
|
- |
| 8.6.1(Mechanical combination lock -Endurance test) |
- |
0 |
|
- |
| 8.6.1(Mechanical combination lock-Salt spary test) |
- |
0 |
|
- |
| 8.6.1(Mechanical combination lock-Strength test) |
- |
0 |
|
- |
| 8.6.1(Mechanical combination lock-Aging-stress Dist) |
- |
0 |
|
- |
| 8.6.1(Mechanical combination lock-Moisture Absorp) |
- |
0 |
|
- |
| 8.6.1(Mechanical combination lock-Vibration test) |
- |
0 |
|
- |
| 8.6.1(Mechanical combination lock-Marking) |
- |
0 |
|
- |
| 8.6.1(Any other lock) |
- |
0 |
|
- |
| 8.6.4(Lock Bolt engagement) |
- |
0 |
|
- |
| 8.6.5(Additional provision- retrofitting time lock) |
- |
0 |
|
- |
| 8.7(Automatic re-locking device) |
- |
0 |
|
- |
| 8.8(Cable hole size) |
- |
0 |
|
- |
| 9(Internal fixture) |
- |
0 |
|
- |
| 10(Painting) |
- |
0 |
|
- |
| 10.1(Cross hatch test) |
- |
0 |
|
- |
| 11.1(Marking of safe) |
- |
0 |
|
- |
| 12(Burglary attack) |
- |
0 |
|
- |
| 12(Fire Resistance) |
- |
0 |
|
- |
| 4(Classification) |
- |
0 |
|
- |
| 5.1(Dimensions) |
- |
0 |
|
- |
| 5.2(Sizes) |
- |
0 |
|
- |
| 5.2(Table-2)(Inside dimensions) |
- |
0 |
|
- |
| 5.2(Table-2)(Tolerance on inside dimensions) |
- |
0 |
|
- |
| 5.2(Table-2)(Internal volume) |
- |
0 |
|
- |
| 5.2(Table-2)(Tolerance on interanal volume) |
- |
0 |
|
- |
| 5.2(Table-2)(Minumum Weight) |
- |
0 |
|
- |
| 5.2(Table-2)(Thickness of Plates (outer bodys& Door)) |
- |
0 |
|
- |
| 5.2(Table-2)(Thickness of Door slab) |
- |
0 |
|
- |
| 5.2(Table-2)(Thickness of door overbolt work) |
- |
0 |
|
- |
| 5.2(Table-2)(Number of lock on the door) |
- |
0 |
|
- |
| 5.2(Table-2)(Any other type of lock) |
- |
0 |
|
- |
| 5.2(Table-2)(Number of bolt on hinge side) |
- |
0 |
|
- |
| 5.2(Table-2)(Number of bolt on opposite hinge) |
- |
0 |
|
- |
| 5.2(Table-2)(No.of bolt at the top) |
- |
0 |
|
- |
| 5.2(Table-2)(No.of bolt at the bottom) |
- |
0 |
|
- |
| 5.2(Table-2)(Size of each bolt (area of bolt section)) |
- |
0 |
|
- |
| 5.2(Table-2)(Depth engagement of bolt) |
- |
0 |
|
- |
| 6(Material declaration) |
- |
0 |
|
- |
| 7(Desigantion-Delaration) |
- |
0 |
|
- |
| 8.1(Body (Construction & workmanship)) |
- |
0 |
|
- |
| 8.2(Door (Gap)) |
- |
0 |
|
- |
| 8.4.1(Hinges) |
- |
0 |
|
- |
| 8.4.2(Bolts) |
- |
0 |
|
- |
| 8.5(Handle) |
- |
0 |
|
- |
| 8.6.1(Lock (key type) Garde) |
- |
0 |
|
- |
| 8.6.1(Lock (key type)classification) |
- |
0 |
|
- |
| 8.6.1(Lock (key type)construction) |
- |
0 |
|
- |
| 8.6.1(Lock(key type) leaver thickness) |
- |
0 |
|
- |
| 8.6.1(Lock (key type)Material) |
- |
0 |
|
- |
| 8.6.1(Lock (key type)corrosion protection materail) |
- |
0 |
|
- |
| 8.6.1(Lock(key type) -Endurance test) |
- |
0 |
|
- |
| 8.6.1(Lock(key type)-Bolt forcing test) |
- |
0 |
|
- |
| 8.6.1(Lock(key type)-salt spray solution test) |
- |
0 |
|
- |
| 8.6.1(Lock(key type)-key strength test) |
- |
0 |
|
- |
| 8.6.1(Lock(key type) -Marking) |
- |
0 |
|
- |
| 8.6.1(Lock(Key type) -Key Marking) |
- |
0 |
|
- |
| 8.6.1(Mechanical combination lock -Classification) |
- |
0 |
|
- |
| 8.6.1(Mechanical combination lock -Construction) |
- |
0 |
|
- |
| 8.6.1(Mechanical combination lock -Metallic parts) |
- |
0 |
|
- |
| 8.6.1(Mechanical combination lock -Corrosion Prot) |
- |
0 |
|
- |
| 8.6.1(Mechanical combination lock -Operation test) |
- |
0 |
|
- |
| 8.6.1(Mechanical cmbination lock -Manipulation) |
- |
0 |
|
- |
| 8.6.1(Mechanical combination lock -Punching attack) |
- |
0 |
|
- |
| 8.6.1(Mechanical combination lock -Endurance test) |
- |
0 |
|
- |
| 8.6.1(Mechanical combination lock-Salt spary test) |
- |
0 |
|
- |
| 8.6.1(Mechanical combination lock-Strength test) |
- |
0 |
|
- |
| 8.6.1(Mechanical combination lock-Aging-stress Dist) |
- |
0 |
|
- |
| 8.6.1(Mechanical combination lock-Moisture Absorp) |
- |
0 |
|
- |
| 8.6.1(Mechanical combination lock-Vibration test) |
- |
0 |
|
- |
| 8.6.1(Mechanical combination lock-Marking) |
- |
0 |
|
- |
| 8.6.1(Any other lock) |
- |
0 |
|
- |
| 8.6.4(Lock Bolt engagement) |
- |
0 |
|
- |
| 8.6.5(Additional provision- retrofitting time lock) |
- |
0 |
|
- |
| 8.7(Automatic re-locking device) |
- |
0 |
|
- |
| 8.8(Cable hole size) |
- |
0 |
|
- |
| 9(Internal fixture) |
- |
0 |
|
- |
| 10(Painting) |
- |
0 |
|
- |
| 10.1(Cross hatch test) |
- |
0 |
|
- |
| 11.1(Marking of safe) |
- |
0 |
|
- |
| 12(Burglary attack) |
- |
0 |
|
- |
| 12(Fire Resistance) |
- |
0 |
|
- |
|
08 Feb, 2027 |
- Included w.e.f. 01.04.2025 |
| 7104 |
Ace Test Labs & Metrology Pvt. Ltd., Sonipat
| 9162826
| IS 5244 (2020) |
Safe Deposit Locker Cabinets — Specification ( Fourth Revision ) |
- |
30000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl. 4.1( Types ) |
- |
1000 |
|
- |
| Cl. 6 (Fig-5)(Cabinet Size (in mm)) |
- |
1000 |
|
- |
| Table 1(Thickness Min. (in mm)) |
- |
1000 |
|
- |
| Table 1(Thickness Min. (in mm)) |
- |
1000 |
|
- |
| Table 1(Thickness Min. (in mm)) |
- |
1000 |
|
- |
| Table 1(Thickness Min. (in mm)) |
- |
1000 |
|
- |
| Table 1(Thickness Min. (in mm)) |
- |
1000 |
|
- |
| Table 1(Thickness Min. (in mm)) |
- |
1000 |
|
- |
| Table 1(Thickness Min. (in mm)) |
- |
1000 |
|
- |
| Table 1(Thickness Min. (in mm)) |
- |
1000 |
|
- |
| Table 1(Thickness Min. (in mm)) |
- |
1000 |
|
- |
| Table 1(Thickness Min. (in mm)) |
- |
1000 |
|
- |
| Table 1(Finish) |
- |
1000 |
|
- |
| Table 1(Finish) |
- |
1000 |
|
- |
| Cl.6(Sizes (Minimum Inside Measurements of locker) Locker Size) |
- |
1000 |
|
- |
| Cl.6(Sizes (Minimum Inside Measurements of locker) Locker Size) |
- |
1000 |
|
- |
| Cl.6(Sizes (Minimum Inside Measurements of locker) Locker Size) |
- |
1000 |
|
- |
| Cl. 7.1(Design and Manufacture) |
- |
1000 |
|
- |
| Cl. 7.1(Design and Manufacture) |
- |
1000 |
|
- |
| Cl. 7.1(Design and Manufacture) |
- |
1000 |
|
- |
| Cl. 7.1(Design and Manufacture) |
- |
1000 |
|
- |
| Cl. 7.1(Design and Manufacture) |
- |
1000 |
|
- |
| Cl. 7.2(Design and Manufacture) |
- |
1000 |
|
- |
| Cl. 7.3(Design and Manufacture) |
- |
1000 |
|
- |
| Cl. 7.3(Design and Manufacture) |
- |
1000 |
|
- |
| Cl. 7.4(Design and Manufacture) |
- |
1000 |
|
- |
| Cl. 7.5(Design and Manufacture) |
- |
1000 |
|
- |
| Cl. 7.6(Design and Manufacture) |
- |
1000 |
|
- |
| Cl. 8(Workmanship) |
- |
1000 |
|
- |
| Cl. 8.2(Tolerance) |
- |
1000 |
|
- |
| Cl. 9.1(Testing) |
- |
1000 |
|
- |
| Cl. 9.2(Testing) |
- |
1000 |
|
- |
| Cl. 9.3(Cross Hatch Test) |
- |
1000 |
|
- |
| Cl. 10.1(Marking) |
- |
1000 |
|
- |
| Cl. 10.2(Marking) |
- |
1000 |
|
- |
| Cl. 10.3(Marking) |
- |
1000 |
|
- |
| Cl. 10.4(Marking on Keys) |
- |
1000 |
|
- |
| Cl. 11(Packing) |
- |
1000 |
|
- |
| Cl. 4.1( Types ) |
- |
1000 |
|
- |
| Cl. 6 (Fig-5)(Cabinet Size (in mm)) |
- |
1000 |
|
- |
| Table 1(Thickness Min. (in mm)) |
- |
1000 |
|
- |
| Table 1(Thickness Min. (in mm)) |
- |
1000 |
|
- |
| Table 1(Thickness Min. (in mm)) |
- |
1000 |
|
- |
| Table 1(Thickness Min. (in mm)) |
- |
1000 |
|
- |
| Table 1(Thickness Min. (in mm)) |
- |
1000 |
|
- |
| Table 1(Thickness Min. (in mm)) |
- |
1000 |
|
- |
| Table 1(Thickness Min. (in mm)) |
- |
1000 |
|
- |
| Table 1(Thickness Min. (in mm)) |
- |
1000 |
|
- |
| Table 1(Thickness Min. (in mm)) |
- |
1000 |
|
- |
| Table 1(Thickness Min. (in mm)) |
- |
1000 |
|
- |
| Table 1(Finish) |
- |
1000 |
|
- |
| Table 1(Finish) |
- |
1000 |
|
- |
| Cl.6(Sizes (Minimum Inside Measurements of locker) Locker Size) |
- |
1000 |
|
- |
| Cl.6(Sizes (Minimum Inside Measurements of locker) Locker Size) |
- |
1000 |
|
- |
| Cl.6(Sizes (Minimum Inside Measurements of locker) Locker Size) |
- |
1000 |
|
- |
| Cl. 7.1(Design and Manufacture) |
- |
1000 |
|
- |
| Cl. 7.1(Design and Manufacture) |
- |
1000 |
|
- |
| Cl. 7.1(Design and Manufacture) |
- |
1000 |
|
- |
| Cl. 7.1(Design and Manufacture) |
- |
1000 |
|
- |
| Cl. 7.1(Design and Manufacture) |
- |
1000 |
|
- |
| Cl. 7.2(Design and Manufacture) |
- |
1000 |
|
- |
| Cl. 7.3(Design and Manufacture) |
- |
1000 |
|
- |
| Cl. 7.3(Design and Manufacture) |
- |
1000 |
|
- |
| Cl. 7.4(Design and Manufacture) |
- |
1000 |
|
- |
| Cl. 7.5(Design and Manufacture) |
- |
1000 |
|
- |
| Cl. 7.6(Design and Manufacture) |
- |
1000 |
|
- |
| Cl. 8(Workmanship) |
- |
1000 |
|
- |
| Cl. 8.2(Tolerance) |
- |
1000 |
|
- |
| Cl. 9.1(Testing) |
- |
1000 |
|
- |
| Cl. 9.2(Testing) |
- |
1000 |
|
- |
| Cl. 9.3(Cross Hatch Test) |
- |
1000 |
|
- |
| Cl. 10.1(Marking) |
- |
1000 |
|
- |
| Cl. 10.2(Marking) |
- |
1000 |
|
- |
| Cl. 10.3(Marking) |
- |
1000 |
|
- |
| Cl. 10.4(Marking on Keys) |
- |
1000 |
|
- |
| Cl. 11(Packing) |
- |
1000 |
|
- |
| Cl. 4.1( Types ) |
- |
1000 |
|
- |
| Cl. 6 (Fig-5)(Cabinet Size (in mm)) |
- |
1000 |
|
- |
| Table 1(Thickness Min. (in mm)) |
- |
1000 |
|
- |
| Table 1(Thickness Min. (in mm)) |
- |
1000 |
|
- |
| Table 1(Thickness Min. (in mm)) |
- |
1000 |
|
- |
| Table 1(Thickness Min. (in mm)) |
- |
1000 |
|
- |
| Table 1(Thickness Min. (in mm)) |
- |
1000 |
|
- |
| Table 1(Thickness Min. (in mm)) |
- |
1000 |
|
- |
| Table 1(Thickness Min. (in mm)) |
- |
1000 |
|
- |
| Table 1(Thickness Min. (in mm)) |
- |
1000 |
|
- |
| Table 1(Thickness Min. (in mm)) |
- |
1000 |
|
- |
| Table 1(Thickness Min. (in mm)) |
- |
1000 |
|
- |
| Table 1(Finish) |
- |
1000 |
|
- |
| Table 1(Finish) |
- |
1000 |
|
- |
| Cl.6(Sizes (Minimum Inside Measurements of locker) Locker Size) |
- |
1000 |
|
- |
| Cl.6(Sizes (Minimum Inside Measurements of locker) Locker Size) |
- |
1000 |
|
- |
| Cl.6(Sizes (Minimum Inside Measurements of locker) Locker Size) |
- |
1000 |
|
- |
| Cl. 7.1(Design and Manufacture) |
- |
1000 |
|
- |
| Cl. 7.1(Design and Manufacture) |
- |
1000 |
|
- |
| Cl. 7.1(Design and Manufacture) |
- |
1000 |
|
- |
| Cl. 7.1(Design and Manufacture) |
- |
1000 |
|
- |
| Cl. 7.1(Design and Manufacture) |
- |
1000 |
|
- |
| Cl. 7.2(Design and Manufacture) |
- |
1000 |
|
- |
| Cl. 7.3(Design and Manufacture) |
- |
1000 |
|
- |
| Cl. 7.3(Design and Manufacture) |
- |
1000 |
|
- |
| Cl. 7.4(Design and Manufacture) |
- |
1000 |
|
- |
| Cl. 7.5(Design and Manufacture) |
- |
1000 |
|
- |
| Cl. 7.6(Design and Manufacture) |
- |
1000 |
|
- |
| Cl. 8(Workmanship) |
- |
1000 |
|
- |
| Cl. 8.2(Tolerance) |
- |
1000 |
|
- |
| Cl. 9.1(Testing) |
- |
1000 |
|
- |
| Cl. 9.2(Testing) |
- |
1000 |
|
- |
| Cl. 9.3(Cross Hatch Test) |
- |
1000 |
|
- |
| Cl. 10.1(Marking) |
- |
1000 |
|
- |
| Cl. 10.2(Marking) |
- |
1000 |
|
- |
| Cl. 10.3(Marking) |
- |
1000 |
|
- |
| Cl. 10.4(Marking on Keys) |
- |
1000 |
|
- |
| Cl. 11(Packing) |
- |
1000 |
|
- |
|
14 Nov, 2027 |
- Included w.e.f. 28.03.2025 |
| 7105 |
URS PRODUCTS AND TESTING PVT. LTD. (A29), NOIDA
| 8168906
| IS 15558 (2005) |
Mini domestic water heater for use with LPG - Specification |
- |
9700 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 17(Combustion) |
- |
800 |
|
- |
| 6.1(Connections) |
- |
200 |
|
- |
| 6.2(Connections) |
- |
200 |
|
- |
| 6.3(Connections) |
- |
200 |
|
- |
| 6.4(Connections) |
- |
200 |
|
- |
| 6.5(Connections) |
- |
200 |
|
- |
| 6.6(Gas Inlet Connections) |
- |
200 |
|
- |
| 6.6(Gas Inlet Connections) |
- |
200 |
|
- |
| 6.6(Gas Inlet Connections) |
- |
200 |
|
- |
| 6.6(Gas Inlet Connections) |
- |
200 |
|
- |
| 6.6(Gas Inlet Connections) |
- |
200 |
|
- |
| 6.6(Gas Inlet Connections) |
- |
200 |
|
- |
| 24(Fire Hazard And Limiting Temperature ) |
- |
500 |
|
- |
| 24(Fire Hazard And Limiting Temperature) |
- |
500 |
|
- |
| 24(Fire Hazard And Limiting Temperature) |
- |
500 |
|
- |
| 24(Fire Hazard And Limiting Temperature) |
- |
500 |
|
- |
| 9(Flame Failure Device) |
- |
400 |
|
- |
| 20(Flame Stability) |
- |
500 |
|
- |
| 7(Flame Visibility) |
- |
300 |
|
- |
| 22(Flash Back) |
- |
400 |
|
- |
| 18(Gas Consumption) |
- |
800 |
|
- |
| 14(Gas Soundness) |
- |
500 |
|
- |
| 8(Gas Taps) |
- |
300 |
|
- |
| 19.1(Ignition and flame travel) |
- |
500 |
|
- |
| 19.2(Ignition and flame travel) |
- |
500 |
|
- |
| 19.3(Ignition and flame travel) |
- |
500 |
|
- |
| 10(Ignition Device) |
- |
400 |
|
- |
| 5.1(Materials) |
- |
200 |
|
- |
| 5.2(Materials) |
- |
200 |
|
- |
| 5.3(Materials) |
- |
200 |
|
- |
| 5.4(Materials) |
- |
200 |
|
- |
| 5.5(Materials) |
- |
200 |
|
- |
| 21(Noise Control) |
- |
400 |
|
- |
| 11(Protection Against Accidental Overheating) |
- |
400 |
|
- |
| 23(Resistance to Draught) |
- |
400 |
|
- |
| 16(Thermal Efficiency) |
- |
800 |
|
- |
| 16(Thermal Efficiency) |
- |
800 |
|
- |
| 25(Time For Temperature Rise) |
- |
500 |
|
- |
| 4.1.1(Construction) |
- |
200 |
|
- |
| 4.1.2(Construction) |
- |
200 |
|
- |
| 4.1.3(Construction) |
- |
200 |
|
- |
| 4.1.4(Construction) |
- |
200 |
|
- |
| 4.1.5(Construction) |
- |
200 |
|
- |
| 4.1.6(Construction) |
- |
200 |
|
- |
| 4.1.7(Construction) |
- |
200 |
|
- |
| 4.1.8(Construction) |
- |
200 |
|
- |
| 4.1.9(Construction) |
- |
200 |
|
- |
| 4.1.10(Construction) |
- |
200 |
|
- |
| 4.1.11(Construction) |
- |
400 |
|
- |
| 4.1.12(Construction) |
- |
200 |
|
- |
| 26(Hot Water Output Test) |
- |
800 |
|
- |
| 27(Marking) |
- |
200 |
|
- |
| 12(Water Rate Adjuster) |
- |
500 |
|
- |
| 15(Water Soundness) |
- |
500 |
|
- |
|
- |
- - |
| 7106 |
ACCURATE TEST SOLUTIONS LLP (F21), NOIDA
| 8141226
| IS 302 : Part 2 : Sec 30 (2007) |
Safety of household and similar electrical appliances: Part 2 particular requirements: Sec 30 room heaters (First Revision) |
- |
20000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl.6 (Classification) |
- |
500 |
|
- |
| Cl.6 (Classification) |
- |
500 |
|
- |
| Cl.7 & IS:302-1:2008(Marking and Instructions) |
- |
500 |
|
- |
| Cl.7 & IS:302-1:2008(Marking and Instructions) |
- |
500 |
|
- |
| Cl.7 & IS:302-1:2008(Marking and Instructions) |
- |
500 |
|
- |
| Cl.7 & IS:302-1:2008(Marking and Instructions) |
- |
500 |
|
- |
| Cl.7 & IS:302-1:2008(Marking and Instructions) |
- |
500 |
|
- |
| Cl.7 & IS:302-1:2008(Marking and Instructions) |
- |
500 |
|
- |
| Cl.7 & IS:302-1:2008(Marking and Instructions) |
- |
500 |
|
- |
| Cl.7 & IS:302-1:2008(Marking and Instructions) |
- |
500 |
|
- |
| Cl.7 & IS:302-1:2008(Marking and Instructions) |
- |
500 |
|
- |
| Cl.7(Marking and Instructions) |
- |
500 |
|
- |
| Cl.7(Marking and Instructions) |
- |
500 |
|
- |
| Cl.7(Marking and Instructions) |
- |
500 |
|
- |
| Cl.7.3(Marking and Instructions) |
- |
500 |
|
- |
| Cl.7.3(Marking and Instructions) |
- |
500 |
|
- |
| Cl.7.3(Marking and Instructions) |
- |
500 |
|
- |
| Cl.7.4(Marking and Instructions) |
- |
500 |
|
- |
| Cl.7.5(Marking and Instructions) |
- |
500 |
|
- |
| Cl.7.6 & IS:302-1:2008(Marking and Instructions) |
- |
500 |
|
- |
| Cl.7.8 of IS :302-1:2008(Marking and Instructions) |
- |
500 |
|
- |
| Cl.7.9 of IS :302-1:2008(Marking and Instructions) |
- |
500 |
|
- |
| Cl.7.10 of IS :302-1:2008(Marking and Instructions) |
- |
500 |
|
- |
| Cl.7.11 of IS :302-1:2008(Marking and Instructions) |
- |
500 |
|
- |
| Cl.7.12 & IS:302-1:2008(Marking and Instructions) |
- |
500 |
|
- |
| Cl.7.12 & IS:302-1:2008(Marking and Instructions) |
- |
500 |
|
- |
| Cl.7.12 & IS:302-1:2008(Marking and Instructions) |
- |
500 |
|
- |
| Cl.7.12 & IS:302-1:2008(Marking and Instructions) |
- |
500 |
|
- |
| Cl.7.12 & IS:302-1:2008(Marking and Instructions) |
- |
500 |
|
- |
| Cl.7.12 & IS:302-1:2008(Marking and Instructions) |
- |
500 |
|
- |
| Cl.7.12 & IS:302-1:2008(Marking and Instructions) |
- |
500 |
|
- |
| Cl.7.12 & IS:302-1:2008(Marking and Instructions) |
- |
500 |
|
- |
| Cl.7.12 & IS:302-1:2008(Marking and Instructions) |
- |
500 |
|
- |
| Cl.7.12 & IS:302-1:2008(Marking and Instructions) |
- |
500 |
|
- |
| Cl.7.12 & IS:302-1:2008(Marking and Instructions) |
- |
500 |
|
- |
| Cl.7.12 & IS:302-1:2008(Marking and Instructions) |
- |
500 |
|
- |
| Cl.7.12.1 & IS:302-1:2008(Marking and Instructions) |
- |
500 |
|
- |
| Cl.7.12.1 & IS:302-1:2008(Marking and Instructions) |
- |
500 |
|
- |
| Cl.7.12.1 & IS:302-1:2008(Marking and Instructions) |
- |
500 |
|
- |
| Cl.7.12.1 & IS:302-1:2008(Marking and Instructions) |
- |
500 |
|
- |
| Cl.7.12.1 & IS:302-1:2008(Marking and Instructions) |
- |
500 |
|
- |
| Cl.7.12.1 & IS:302-1:2008(Marking and Instructions) |
- |
500 |
|
- |
| Cl.7.12.1 & IS:302-1:2008(Marking and Instructions) |
- |
500 |
|
- |
| Cl.7.12.1 & IS:302-1:2008(Marking and Instructions) |
- |
500 |
|
- |
| Cl.7.12.1 & IS:302-1:2008(Marking and Instructions) |
- |
500 |
|
- |
| Cl.7.12.1 & IS:302-1:2008(Marking and Instructions) |
- |
500 |
|
- |
| Cl.7.12.1 & IS:302-1:2009(Marking and Instructions) |
- |
500 |
|
- |
| Cl.7.13 of IS 302-1:2008(Marking and Instructions) |
- |
500 |
|
- |
| Cl.7.14 of IS302-1:2008(Marking and Instructions) |
- |
500 |
|
- |
| Cl.7.14(Marking and Instructions) |
- |
500 |
|
- |
| Cl.7.14(Marking and Instructions) |
- |
500 |
|
- |
| Cl.7.15 of IS 302-1:2008(Marking and Instructions) |
- |
500 |
|
- |
| Cl.7.15 of IS 302-1:2008(Marking and Instructions) |
- |
500 |
|
- |
| Cl.7.15 of IS 302-1:2008(Marking and Instructions) |
- |
500 |
|
- |
| Cl.7.15 of IS 302-1:2008(Marking and Instructions) |
- |
500 |
|
- |
| Cl.7.101(Marking and Instructions) |
- |
500 |
|
- |
| Cl.8 & IS:302-1:2008(Protection Against Access to Live Parts) |
- |
500 |
|
- |
| Cl.10 & IS:302-1:2008(Power Input and Current) |
- |
500 |
|
- |
| Cl.11 & IS:302-1:2008(Heating) |
- |
500 |
|
- |
| Cl.11 & IS:302-1:2008(Heating) |
- |
500 |
|
- |
| Cl.11 & IS:302-1:2008(Heating) |
- |
500 |
|
- |
| Cl.11 & IS:302-1:2008(Heating) |
- |
500 |
|
- |
| Cl.11 & IS:302-1:2008(Heating) |
- |
500 |
|
- |
| Cl.11 & IS:302-1:2008(Heating) |
- |
500 |
|
- |
| Cl.11 & IS:302-1:2008(Heating) |
- |
500 |
|
- |
| Cl.11 & IS:302-1:2008(Heating) |
- |
500 |
|
- |
| Cl.11 & IS:302-1:2008(Heating) |
- |
500 |
|
- |
| Cl.11 & IS:302-1:2008(Heating) |
- |
500 |
|
- |
| Cl.11 & IS:302-1:2008(Heating) |
- |
500 |
|
- |
| Cl.11 & IS:302-1:2008(Heating) |
- |
500 |
|
- |
| Cl.11 & IS:302-1:2008(Heating) |
- |
500 |
|
- |
| Cl.11 & IS:302-1:2008(Heating) |
- |
500 |
|
- |
| Cl.11 & IS:302-1:2008(Heating) |
- |
500 |
|
- |
| Cl.11 & IS:302-1:2008(Heating) |
- |
500 |
|
- |
| Cl.11.8(Heating) |
- |
500 |
|
- |
| Cl.11.8(Heating) |
- |
500 |
|
- |
| Cl.11.8(Heating) |
- |
500 |
|
- |
| Cl.13 & IS:302-1:2008(Leakage Current & Electric Strength at operating temp. ) |
- |
500 |
|
- |
| Cl.13 & IS:302-1:2008(Leakage Current & Electric Strength at operating temp. ) |
- |
500 |
|
- |
| Cl.14 & IS:302-1:2008(Transient Over Voltages) |
- |
500 |
|
- |
| Cl.15 & IS: 302-1:2008(Moisture Resistance
) |
- |
500 |
|
- |
| Cl.15.3 of IS 302-1:200(Moisture Resistance
) |
- |
500 |
|
- |
| Cl.16 & IS:302-1:2008(Leakage Current & Electric Strength ) |
- |
500 |
|
- |
| Cl.16 & IS:302-1:2008(Leakage Current & Electric Strength ) |
- |
500 |
|
- |
| Cl.17 & IS:302-1:2008(Over load Protection of Transformers and Associated Circuits ) |
- |
500 |
|
- |
| Cl.18 (Endurance. ) |
- |
0 |
|
- |
| Cl.19 & IS:302-1:2008(Abnormal Operation.) |
- |
500 |
|
- |
| Cl.19 & IS:302-1:2008(Abnormal Operation.) |
- |
500 |
|
- |
| Cl.19 & IS:302-1:2008(Abnormal Operation.) |
- |
500 |
|
- |
| Cl.19 & IS:302-1:2008(Abnormal Operation.) |
- |
500 |
|
- |
| Cl.19.101(Abnormal Operation.) |
- |
500 |
|
- |
| Cl.19.102(Abnormal Operation.) |
- |
500 |
|
- |
| Cl.19.103(Abnormal Operation.) |
- |
500 |
|
- |
| Cl.19.104(Abnormal Operation.) |
- |
500 |
|
- |
| Cl.19.105(Abnormal Operation.) |
- |
500 |
|
- |
| Cl.19.106(Abnormal Operation.) |
- |
500 |
|
- |
| Table 8 of IS 302-1:2008(Abnormal Operation.) |
- |
500 |
|
- |
| Cl.19.107(Abnormal Operation.) |
- |
500 |
|
- |
| Cl.19.108(Abnormal Operation.) |
- |
500 |
|
- |
| Cl.19.109(Abnormal Operation.) |
- |
500 |
|
- |
| Cl.19.110(Abnormal Operation.) |
- |
500 |
|
- |
| Cl.19.111(Abnormal Operation.) |
- |
500 |
|
- |
| Cl.19.112(Abnormal Operation.) |
- |
500 |
|
- |
| Cl.19.113(Abnormal Operation.) |
- |
500 |
|
- |
| Cl.19.114(Abnormal Operation.) |
- |
500 |
|
- |
| Cl.20 & IS:302-1:2008(Stability & Mechanical Hazards) |
- |
500 |
|
- |
| Cl.21 & IS:302-1:2008)(Mechanical Strength.) |
- |
500 |
|
- |
| Cl.21.2 of IS 302-1:2008(Mechanical Strength.) |
- |
500 |
|
- |
| Cl.21.101 (Mechanical Strength.) |
- |
500 |
|
- |
| Cl.21.102(Mechanical Strength.) |
- |
500 |
|
- |
| Cl.21.103(Mechanical Strength.) |
- |
500 |
|
- |
| Cl.22.1 of IS 302-1:2008(Construction) |
- |
500 |
|
- |
| Cl.22.5 of IS 302-1:2008(Construction) |
- |
500 |
|
- |
| Cl.22.6 of IS 302-1:2008(Construction) |
- |
500 |
|
- |
| Cl.22.7 of IS 302-1:2008(Construction) |
- |
500 |
|
- |
| Cl.22.8 of IS 302-1:2008(Construction) |
- |
500 |
|
- |
| Cl.22.9 of IS 302-1:2008(Construction) |
- |
500 |
|
- |
| Cl.22.11(Construction) |
- |
500 |
|
- |
| Cl.22.12 of IS 302-1:2008(Construction) |
- |
500 |
|
- |
| Cl.22.13 of IS 302-1:2008(Construction) |
- |
500 |
|
- |
| Cl.22.14 of IS 302-1:2008(Construction) |
- |
500 |
|
- |
| Cl.22.15 of IS 302-1:2008(Construction) |
- |
500 |
|
- |
| Cl.22.18 of IS 302-1:2008(Construction) |
- |
500 |
|
- |
| Cl.22.20 of IS 302-1:2008(Construction) |
- |
500 |
|
- |
| Cl.22.21 of IS 302-1:2008(Construction) |
- |
500 |
|
- |
| Cl.23 & IS:302-1:2008(Internal Wiring
) |
- |
500 |
|
- |
| Cl.23.4 & Cl.29 of 302-1:2008(Internal Wiring
) |
- |
500 |
|
- |
| Cl.23.5 of 302-1:2008(Internal Wiring
) |
- |
500 |
|
- |
| Cl.23.7 of 302-1:2008(Internal Wiring
) |
- |
500 |
|
- |
| C.23.7 of 302-1:2008(Internal Wiring
) |
- |
500 |
|
- |
| Cl.25.1 of 302-1:2008(Supply Connection and External Flexible Cords ) |
- |
500 |
|
- |
| Cl. 25.2 of IS 3021:2008(Supply Connection and External Flexible Cords ) |
- |
500 |
|
- |
| Cl. 25.3 of IS 302-1:2008(Supply Connection and External Flexible Cords ) |
- |
500 |
|
- |
| Cl. 25.4 of IS 302-1:2008(Supply Connection and External Flexible Cords ) |
- |
500 |
|
- |
| Cl.25.5 of 302-1:2008(Supply Connection and External Flexible Cords ) |
- |
500 |
|
- |
| Cl.25.7.(Supply Connection and External Flexible Cords ) |
- |
500 |
|
- |
| Cl.25.8(Supply Connection and External Flexible Cords ) |
- |
500 |
|
- |
| Cl. 25.9(Supply Connection and External Flexible Cords ) |
- |
500 |
|
- |
| Cl.25.10 of 302-1:2008(Supply Connection and External Flexible Cords ) |
- |
500 |
|
- |
| Cl. 25.11(Supply Connection and External Flexible Cords ) |
- |
500 |
|
- |
| Cl. 25.12(Supply Connection and External Flexible Cords ) |
- |
500 |
|
- |
| Cl. 25.13(Supply Connection and External Flexible Cords ) |
- |
500 |
|
- |
| Cl.25.14 of IS 302-1:2008(Supply Connection and External Flexible Cords ) |
- |
500 |
|
- |
| Cl.25.15 of IS 302-1:2008(Supply Connection and External Flexible Cords ) |
- |
500 |
|
- |
| Cl.25.15 of IS 302-1:2008(Supply Connection and External Flexible Cords ) |
- |
500 |
|
- |
| Cl.25.18(Supply Connection and External Flexible Cords ) |
- |
500 |
|
- |
| Cl.25.20(Supply Connection and External Flexible Cords ) |
- |
500 |
|
- |
| Cl.26.1 of IS 302-1:2008(Terminal for External Conductors
) |
- |
500 |
|
- |
| Cl.26.10 of IS 302-1:2008(Terminal for External Conductors
) |
- |
500 |
|
- |
| Cl.26.11 of IS 302-1:2008(Terminal for External Conductors
) |
- |
500 |
|
- |
| Cl.27.1 of 302-1:2008(Provision for Earthing.) |
- |
500 |
|
- |
| Cl.27.5 of 302-1:2008(Provision for Earthing.) |
- |
500 |
|
- |
| Cl.28 of 302-1:2008(Screws and Connections.) |
- |
500 |
|
- |
| Cl.29 & IS:302-1:2008(Clearances, Creepage Distances and Solid Insulation) |
- |
500 |
|
- |
| Cl.29 & IS:302-1:2008(Clearances, Creepage Distances and Solid Insulation) |
- |
500 |
|
- |
| Cl.30 & IS:302-1:2008(Resistance to Heat and Fire) |
- |
500 |
|
- |
| Cl.30.2.2 of 302-1:2008(Resistance to Heat and Fire) |
- |
500 |
|
- |
| Cl.31 & IS:302-1:2008(Resistance to Rusting.) |
- |
500 |
|
- |
| Cl.32 & IS:302-1:2008(Radition,Toxicity and similar Hazards.) |
- |
500 |
|
- |
| Cl.31 of IS:302-1:2008(Resistance to Rusting.) |
- |
500 |
|
- |
| Cl.30.2 of 302-1:2008(Resistance to Heat and Fire : Resistance to fire) |
- |
500 |
|
- |
| Cl.30.1 of IS:302-1:2008(Resistance to Heat and Fire: Resistance to heat. ) |
- |
500 |
|
- |
| Cl.29.2 of IS:302-1:2008(Clearances, Creepage Distances and Solid Insulation : Creepage Distance) |
- |
500 |
|
- |
| Cl.29.1 of IS:302-1:2008(Clearances, Creepage Distances and Solid Insulation : Clearance ) |
- |
500 |
|
- |
| Cl.28 of 302-1:2008(Screws and Connections.) |
- |
500 |
|
- |
| Cl.27.5 of 302-1:2008(Provision for Earthing : ECR) |
- |
500 |
|
- |
| Cl.27.1 of 302-1:2008(Provision for Earthing ) |
- |
500 |
|
- |
| Cl.26 of IS 302-1:2008(Terminal for External Conductors
) |
- |
500 |
|
- |
| Cl.25.20 of 302-1:2008(Supply Connection and External Flexible Cords : Additional insulation ) |
- |
500 |
|
- |
| Cl.25.18 of 302-1:2008(Supply Connection and External Flexible Cords : Arrangement of cord anchorages ) |
- |
500 |
|
- |
| Cl.25.15 of IS 302-1:2008(Supply Connection and External Flexible Cords : Cord grip test - displacement) |
- |
500 |
|
- |
| Cl.25.15 of IS 302-1:2008(Supply Connection and External Flexible Cords : Cord grip test - strain at terminals ) |
- |
500 |
|
- |
| Cl. 25.13 of 302-1:2008(Supply Connection and External Flexible Cords : Inlet opening of supply cords ) |
- |
500 |
|
- |
| Cl. 25.12 of 302-1:2008(Supply Connection and External Flexible Cords : Moulding of cords ) |
- |
500 |
|
- |
| Cl.25.10 of 302-1:2008(Supply Connection and External Flexible Cords : Colour of earthing wire ) |
- |
500 |
|
- |
| Cl. 25.9 of 302-1:2008(Supply Connection and External Flexible Cords : Contact with sharp edge ) |
- |
500 |
|
- |
| Cl.25.8 of 302-1:2008(Supply Connection and External Flexible Cords : Resistance of supply wires ) |
- |
500 |
|
- |
| Cl.25.7 of IS:302-2-30:2007(Supply Connection and External Flexible Cords : Supply cords material ) |
- |
500 |
|
- |
| Cl.25.5 of 302-1:2008(Supply Connection and External Flexible Cords : Type of attachments ) |
- |
500 |
|
- |
| Cl.25.1 of 302-1:2008(Supply Connection and External Flexible Cords : Means of connection ) |
- |
500 |
|
- |
| Cl.23.7 of 302-1:2008(Internal Wiring : Colour of earting conductor
) |
- |
500 |
|
- |
| Cl.23 of IS:302-1:2008(Internal Wiring
) |
- |
500 |
|
- |
| Cl.22.106 of IS:302-2-30:2007(Construction : Checking of thermostats, timers or similar means for visibl glowing radiant heaters) |
- |
500 |
|
- |
| Cl.22.106 of IS:302-2-30:2007(Construction : Checking of openings on the underside) |
- |
500 |
|
- |
| Cl.22.102 & Cl 22.103 of IS:302-2-30:2007(Construction : Fireguard ) |
- |
500 |
|
- |
| Cl.22.101 of IS:302-2-30:2007(Construction : Prevention to contact with heating element) |
- |
500 |
|
- |
| Cl.22.24 of IS:302-2-30:2007(Construction : test of bare heating element) |
- |
500 |
|
- |
| Cl.22.18 of IS 302-1:2008(Construction : Resistance to corrosion ) |
- |
500 |
|
- |
| Cl.22.15 of IS 302-1:2008(Construction : Storage hooks for flexible cords) |
- |
500 |
|
- |
| Cl.22.14 of IS 302-1:2008(Construction : ragged and sharp edges) |
- |
500 |
|
- |
| Cl.22.13 of IS 302-1:2008(Construction : Position of handles ) |
- |
500 |
|
- |
| Cl.22.12 of IS 302-1:2008(Construction : Fixing of Handle, knobs,grips,lever and similer parts ) |
- |
500 |
|
- |
| Cl.22.11 of IS 302-1:2008(Construction : Fixing of non detachable parts ) |
- |
500 |
|
- |
| Cl.22.7 of IS:302-2-30:2007(Construction : Pressure test of oil heater ) |
- |
500 |
|
- |
| Cl.21.101 of IS:302-2-30:2007(Mechanical Strength : fire gaurd deformation test ) |
- |
500 |
|
- |
| Cl.21.2 of IS 302-1:2008(Mechanical Strength : Pentration by sharp implementation ) |
- |
500 |
|
- |
| Cl.21.1 of IS:302-1:2008)(Mechanical Strength : Rough handling ) |
- |
500 |
|
- |
| Cl.20 of IS:302-2-30:2007(Stability of Mechanical Hazards) |
- |
500 |
|
- |
| Cl.19.114 of IS:302-2-30:2007(Abnormal Operation : the temp. of the surface of the container for oil heaters ) |
- |
500 |
|
- |
| Cl.19.112 of IS:302-2-30:2007(Abnormal Operation : Ignition of bleached cotton gauge) |
- |
500 |
|
- |
| Cl.19.111 of IS:302-2-30:2007(Abnormal Operation : Ignition of flannelette for Visibly glowing heaters) |
- |
500 |
|
- |
| Cl.19.110 of IS:302-2-30:2007(Abnormal Operation : operation against wall for visibly glowing radiant heaters ) |
- |
500 |
|
- |
| Cl.19.109 of IS:302-2-30:2007(Abnormal Operation : operation against wall for fan heater ) |
- |
500 |
|
- |
| Cl.19.106 of IS:302-2-30:2007(Abnormal Operation : Locked rotor of fan hetear ) |
- |
500 |
|
- |
| Cl.19.103 , Cl 19.104 of IS:302-2-30:2007(Abnormal Operation : Operation after Covering by cotton) |
- |
500 |
|
- |
| Cl.19 of IS:302-2-30:2007(Abnormal Operation : High Voltage ) |
- |
500 |
|
- |
| Cl.19 of IS:302-2-30:2007(Abnormal Operation : Temp rise of test corner ) |
- |
500 |
|
- |
| Cl.19 of IS:302-2-30:2007(Abnormal Operation : temp rise of supply cord ) |
- |
500 |
|
- |
| Cl.19 of IS:302-1:2008(Abnormal Operation : Emission of molten or poisonous or ignitable gas) |
- |
500 |
|
- |
| Cl.16 of IS:302-1:2008(Leakage current and Electric strength (After humidity): Electric Strentgh ) |
- |
500 |
|
- |
| Cl.16 of IS:302-1:2008(Leakage current and Electric strength (After humidity): Leakage current ) |
- |
500 |
|
- |
| Cl.15 of IS 302-1:2008(Moisture Resistance
) |
- |
500 |
|
- |
| Cl.14 of IS:302-1:2008(Transient Over Voltages) |
- |
500 |
|
- |
| Cl.13 of IS:302-1:2008(Leakage Current of Electric Strength at operating temp. ) |
- |
500 |
|
- |
| Cl.13 of IS:302-1:2008(Leakage Current of Electric Strength at operating temp. ) |
- |
500 |
|
- |
| Cl.11 of IS:302-2:30: 2007(Heating : Room temperature) |
- |
500 |
|
- |
| Cl.11.8 of IS:302-2:30: 2007(Heating : For liquid filled radiators the temp. rise of the outer surface of the liquid container) |
- |
500 |
|
- |
| Cl.11 of IS:302-2:30: 2007(Heating : Temperature rise in winding) |
- |
500 |
|
- |
| Cl.11 of IS:302-2:30: 2007(Heating : Air-outlet grills) |
- |
500 |
|
- |
| Cl.11 of IS:302-2:30: 2007(Heating : Surfaces of handles, knobs, grips and similar parts) |
- |
500 |
|
- |
| Cl.11 of IS:302-2:30: 2007(Heating : Wooden supports, walls, ceiling and floor of the test corner) |
- |
500 |
|
- |
| Cl.11 of IS:302-2:30: 2007(Heating : PVC Insulation ) |
- |
500 |
|
- |
| Cl.10 of IS:302-1:2008(Power Input and Current) |
- |
500 |
|
- |
| Cl.8 of IS:302-1:2008(Protection Against Access to Live Parts) |
- |
500 |
|
- |
| Cl.7.101 of IS:302-2:30: 2007(Marking and Instructions : standard mark. ) |
- |
500 |
|
- |
| Cl.7.15 of IS 302-1:2008(Marking and Instructions : Visibility of marking concerning covering) |
- |
500 |
|
- |
| Cl.7.15 of IS 302-1:2008(Marking and Instructions : discernibility from the out side ) |
- |
500 |
|
- |
| Cl.7.14 of IS:302-2:30: 2007(Marking and Instructions : Height of “Do not cover”) |
- |
500 |
|
- |
| Cl.7.14 of IS:302-2:30: 2007(Marking and Instructions : height of symbol) |
- |
500 |
|
- |
| Cl.7.14 of IS302-1:2008(Marking and Instructions : Legibility and durability ) |
- |
500 |
|
- |
| Cl.7.13 of IS 302-1:2008(Marking and Instructions : Languge of instruction and texts ) |
- |
500 |
|
- |
| Cl.7.11 of IS :302-1:2008(Marking and Instructions : Controls ) |
- |
500 |
|
- |
| Cl.7.9 of IS :302-1:2008(Marking and Instructions : switches ) |
- |
500 |
|
- |
| Cl.7.8 of IS :302-1:2008(Marking and Instructions : terminals ) |
- |
500 |
|
- |
| Cl.7.6 of IS:302-1:2008(Marking and Instructions : Symbols ) |
- |
500 |
|
- |
| Cl.7.5 of IS:302-1:2008(Marking and Instructions : upper of lower limit of the rated power input ) |
- |
500 |
|
- |
| Cl 7.1 & Cl.7.6 of IS:302-2:30: 2007(Marking and Instructions : Do not cover ) |
- |
500 |
|
- |
| Cl.7.1 of IS:302-1:2008(Marking and Instructions : Country of manufacture ) |
- |
500 |
|
- |
| Cl.7.1 of IS:302-1:2008(Marking and Instructions : Symbol for Class-II ) |
- |
500 |
|
- |
| Cl.7.1 of IS:302-1:2008(Marking and Instructions : Model or type ) |
- |
500 |
|
- |
| Cl.7.1 of IS:302-1:2008(Marking and Instructions : Name , trade-mark or identification mark of the manufacturer ) |
- |
500 |
|
- |
| Cl.7.1 of IS:302-1:2008(Marking and Instructions : rated power input ) |
- |
500 |
|
- |
| Cl.7.1 of IS:302-1:2008(Marking and Instructions : Nature of supply ) |
- |
500 |
|
- |
| Cl.7.1 of IS:302-1:2008(Marking and Instructions : Rated Voltage ) |
- |
500 |
|
- |
| Cl.25.6 of 302-1:2008(Supply Connection and External Flexible Cords ) |
- |
500 |
|
- |
| Cl.25.17 of IS 302-1:2008(Supply Connection and External Flexible Cords ) |
- |
500 |
|
- |
| Cl.24.1 of 302-1:2008(Component) |
- |
0 |
|
- |
| Cl.24.1 of 302-1:2008(Component) |
- |
0 |
|
- |
| Cl.24.1.3 (Component) |
- |
0 |
|
- |
| Cl.24.1.3 (Component) |
- |
0 |
|
- |
| Cl.24.1.3 (Component) |
- |
0 |
|
- |
| Cl.24.1.3 (Component) |
- |
0 |
|
- |
| C.24.1.4(Component) |
- |
0 |
|
- |
| C.24.2 of 302-1:2008(Component) |
- |
0 |
|
- |
| Cl.24.10(Component) |
- |
0 |
|
- |
| Cl.24 of IS:302-2-30:2007(Component) |
- |
0 |
|
- |
| 19.11.4.1(Electrostatic discharges) |
- |
0 |
|
- |
| 19.11.4.2(Radiated fields) |
- |
0 |
|
- |
| 19.11.4.3(Fast transient bursts) |
- |
0 |
|
- |
| 19.11.4.4(Surge immunity test) |
- |
0 |
|
- |
| 19.11.4.5(Injected currents) |
- |
0 |
|
- |
| 19.11.4.6(Class 3 Voltage dips and interruptions) |
- |
0 |
|
- |
| 19.11.4.7(Harmonics) |
- |
0 |
|
- |
|
04 Jul, 2027 |
- Included w.e.f.17.03.2025
Exclusion
Cl 19.11.4.1 to Cl 19.11.4.7 (EMI/EMC)
Cl 24 (Components) |
| 7107 |
Alpha Test House Services LLP (160), Sahibzada Ajit Singh Nagar
| 9138706
| IS 1364 : Part 1 (2023) |
Hexagon head bolts, screws, and nuts of property grades A and B: Part 1 Hexagon head bolts (Size range M1.6 to M64) (sixth revision) |
M 1.6 -M 64 |
25000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl-4(Dimensions) |
- |
25000 |
|
- |
| Cl-5, Table-7(General requirements) |
- |
25000 |
|
- |
| Cl-5, Table-7(Thread-Tolerance class) |
- |
25000 |
|
- |
| Cl-5, Table-7(Mechanical properties- Steel) |
- |
25000 |
|
- |
| Cl-5, Table-7(Mechanical properties-Stainless steel) |
- |
25000 |
|
- |
| Cl-5, Table-7(Tolerances-Product grade) |
- |
25000 |
|
- |
| Cl-5, Table-7(Surface condition -Electroplated coatings) |
- |
25000 |
|
- |
| Cl-5, Table-7(Surface condition- Non-electrolytically applied zinc flake) |
- |
1000 |
|
- |
| Cl-5, Table-7(Surface condition - Hot dip galvanized coatings) |
- |
1000 |
|
- |
| Cl-5, Table-7(Surface integrity- Limits for surface discontinuities) |
- |
1000 |
|
- |
| Cl-6(Marking) |
- |
25000 |
|
- |
|
31 Dec, 2029 |
- - |
| 7108 |
Alpha Test House Services LLP (160), Sahibzada Ajit Singh Nagar
| 9138706
| IS 1364 : Part 2 (2018) |
Hexagon head bolts, screws and nuts of product grades A and B: Part 2 hexagon head screws (Size Range M 1.6 To M 64) (Fifth Revision) |
M 1.6- M 64 |
25000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 3(dimensions) |
- |
25000 |
|
- |
| 4(Material) |
- |
25000 |
|
- |
| 4(Thread requirements) |
- |
25000 |
|
- |
| 5(Designation) |
- |
25000 |
|
- |
| 9.1 to 9.5, 9.7(Tensile Test) |
- |
25000 |
|
- |
| 9.8(Head Soundness Test) |
- |
25000 |
|
- |
| 9.13(Torsion Test) |
- |
25000 |
|
- |
| 9.14(Impact Test) |
- |
25000 |
|
- |
| 9.9(Hardness Test) |
- |
25000 |
|
- |
| 9.1(Decarburization Test) |
- |
25000 |
|
- |
| 9.11(Carburization test) |
- |
25000 |
|
- |
| 9.12(Re tempering test) |
- |
25000 |
|
- |
| 9.15(Surface discontinuity test) |
- |
25000 |
|
- |
| 7.2.2(Tensile Strength) |
- |
25000 |
|
- |
| 7.2.3(Stress at 0.2% permanent strain) |
- |
25000 |
|
- |
| 7.2.4(Elongation after fracture) |
- |
25000 |
|
- |
| 7.2.5(Breaking Torque Test) |
- |
1500 |
|
- |
| 7.2.6(Strength under wedge loading) |
- |
25000 |
|
- |
| 7.2.7(Hardness) |
- |
25000 |
|
- |
|
31 Dec, 2029 |
- - |
| 7109 |
CSIR-Central Building Research Institute, Roorkee
| 9184204
| IS 550 : Part 1 (2014) |
Safes: Part 1 specification (Fifth Revision) |
- |
450000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl. 4 Table 1(CLASSIFICATIONS) |
- |
450000 |
|
450000 + GST for two hours |
| Cl. 5 Table 2(DIMENSIONS AND SIZES) |
- |
450000 |
|
450000 + GST for two hours |
| Cl. 5 Table 2(DIMENSIONS AND SIZES) |
- |
450000 |
|
450000 + GST for two hours |
| Cl. 5 Table 2(DIMENSIONS AND SIZES) |
- |
450000 |
|
450000 + GST for two hours |
| Cl. 5 Table 2(DIMENSIONS AND SIZES) |
- |
450000 |
|
450000 + GST for two hours |
| Cl. 5 Table 2(DIMENSIONS AND SIZES) |
- |
450000 |
|
450000 + GST for two hours |
| Cl. 5 Table 2(DIMENSIONS AND SIZES) |
- |
450000 |
|
450000 + GST for two hours |
| Cl. 5 Table 2(DIMENSIONS AND SIZES) |
- |
450000 |
|
450000 + GST for two hours |
| Cl. 5 Table 2(DIMENSIONS AND SIZES) |
- |
450000 |
|
450000 + GST for two hours |
| Cl. 5 Table 10(DIMENSIONS AND SIZES) |
- |
450000 |
|
450000 + GST for two hours |
| Cl. 5 Table 2(DIMENSIONS AND SIZES) |
- |
450000 |
|
450000 + GST for two hours |
| Cl. 5 Table 2(DIMENSIONS AND SIZES) |
- |
450000 |
|
450000 + GST for two hours |
| Cl. 5 Table 2(DIMENSIONS AND SIZES) |
- |
450000 |
|
450000 + GST for two hours |
| Cl. 5 Table 2(DIMENSIONS AND SIZES) |
- |
450000 |
|
450000 + GST for two hours |
| Cl. 5 Table 2(DIMENSIONS AND SIZES) |
- |
450000 |
|
450000 + GST for two hours |
| Cl. 5 Table 2(DIMENSIONS AND SIZES) |
- |
450000 |
|
450000 + GST for two hours |
| Cl. 6 Table 3(Material) |
- |
450000 |
|
450000 + GST for two hours |
| Cl. 7 (DESIGNATIONS) |
- |
450000 |
|
450000 + GST for two hours |
| Cl. 8.1(Body) |
- |
450000 |
|
450000 + GST for two hours |
| Cl. 8.3(Door) |
- |
450000 |
|
450000 + GST for two hours |
| Cl. 8.4.1(Hinges) |
- |
450000 |
|
450000 + GST for two hours |
| Cl. 8.4.2(Bolts) |
- |
450000 |
|
450000 + GST for two hours |
| Cl. 8.5 Table 3(Handles) |
- |
450000 |
|
450000 + GST for two hours |
| Cl. 8.6.1(Locks (Type)) |
- |
450000 |
|
450000 + GST for two hours |
| Cl. 8.6.1.1(Locks (Type)) |
- |
450000 |
|
450000 + GST for two hours |
| Cl. 8.6.2(Locks (Levers)) |
- |
450000 |
|
450000 + GST for two hours |
| Cl. 8.6.3(Tests for locks) |
- |
450000 |
|
450000 + GST for two hours |
| Cl. 8.6.4(Keys) |
- |
450000 |
|
450000 + GST for two hours |
| Cl. 8.6.5(Unpickability) |
- |
450000 |
|
450000 + GST for two hours |
| Cl. 8.6.6(Non-interchangeability) |
- |
450000 |
|
450000 + GST for two hours |
| Cl. 8.7(Automatic Relocking Device) |
- |
450000 |
|
450000 + GST for two hours |
| Cl. 9(INTERNAL FIXTURES) |
- |
450000 |
|
450000 + GST for two hours |
| Cl. 10(Painting) |
- |
450000 |
|
450000 + GST for two hours |
| Cl. 10(Painting) |
- |
450000 |
|
450000 + GST for two hours |
| Cl. 11.1(Marking of Safes) |
- |
450000 |
|
450000 + GST for two hours |
| Cl. 11.2( Marking on Keys) |
- |
450000 |
|
450000 + GST for two hours |
| Cl. 11.3(BIS Certification Marking) |
- |
450000 |
|
450000 + GST for two hours |
|
12 Mar, 2028 |
- - |
| 7110 |
Shiva Analyticals (India) Private Limited, Bengaluru
| 6121716
| IS 14543 (2024) |
Packaged Drinking Water Other than Packaged Natural Mineral Water Specification Third Revision |
- |
20000.00 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 5.3(Appearance) |
- |
200 |
|
- |
| 5.4/Annex D/i(P,P-DDT) |
- |
180 |
|
- |
| 5.4/Annex D/ii(Lindane) |
- |
180 |
|
- |
| 5.4/Annex D/iv(b-Endosulfan) |
- |
180 |
|
- |
| 5.4/Annex D/xvi(Dieldrin) |
- |
180 |
|
- |
| 5.4/Annex D/xvi(Aldrin) |
- |
180 |
|
- |
| 5.4/Annex D/i(O,P-DDT) |
- |
180 |
|
- |
| 5.4/Annex D/iv(a-Endosulfan) |
- |
180 |
|
- |
| 5.4/Annex D/iii(d-HCH) |
- |
180 |
|
- |
| 5.4/Annex D/i(O,P-DDD) |
- |
180 |
|
- |
| 5.4/Annex D/i(P,P-DDE) |
- |
180 |
|
- |
| 5.4/Annex D/i(O,P-DDE) |
- |
180 |
|
- |
| 5.4/Annex D/iii(a-HCH) |
- |
180 |
|
- |
| 5.4/Annex D/iii(β- HCH) |
- |
180 |
|
- |
| 5.4/Annex D/iv(Endosulfan sulfate) |
- |
180 |
|
- |
| 5.4/Annex D/i(P,P-DDD) |
- |
180 |
|
- |
| 5.4/Annex D/xii(Alachlor) |
- |
180 |
|
- |
| 5.4/Annex D/vii(Chlorpyrifos) |
- |
180 |
|
- |
| 5.4/Annex D/x(Butachlor) |
- |
180 |
|
- |
| 5.4/Annex D/vi(Ethion) |
- |
180 |
|
- |
| 5.4/Annex D/xiv(Methyl parathion) |
- |
180 |
|
- |
| 5.4/Annex D/xv(Malathion) |
- |
180 |
|
- |
| 5.4/Annex D/viii(Phorate) |
- |
180 |
|
- |
| 5.4/Annex D/v(Monochrotophos) |
- |
180 |
|
- |
| 5.4/Annex D/xiii(Atrazine) |
- |
180 |
|
- |
| 5.4/Annex D/viii(Phorate sulphoxide) |
- |
180 |
|
- |
| 5.4/Annex D/viii(Phorate sulfone) |
- |
180 |
|
- |
| 5.4/Annex D/xxvii(Methyl paraoxon) |
- |
180 |
|
- |
| 5.4/Annex D/xxviii(Malaoxon) |
- |
180 |
|
- |
| 5.4/Annex D/xi(Isoproturon) |
- |
180 |
|
- |
| 5.4/Annex D/ix(2,4 –D) |
- |
180 |
|
- |
| Cl-5.3, Table-1 (i)(Colour, true colour units, Max) |
- |
200 |
|
- |
| Cl-5.3, Table-1 (ii)(Odour) |
- |
200 |
|
- |
| Cl-5.3, Table-1 (iii)(Taste) |
- |
200 |
|
- |
| Cl-5.3, Table-1 (iv)(Turbidity, nephelometric turbidity unit (NTU), Max) |
- |
200 |
|
- |
| Cl-5.3, Table-1 (v)(Total dissolved solids, mg/l, Max) |
- |
200 |
|
- |
| Cl-5.3, Table-1 (vi)(pH) |
- |
200 |
|
- |
| Cl-5.3, Table-2 (i)(Barium (as Ba)) |
- |
200 |
|
- |
| Cl-5.3, Table-2 (ii)(Copper (as Cu)) |
- |
200 |
|
- |
| Cl-5.3, Table-2 (iii)(Iron (as Fe)) |
- |
200 |
|
- |
| Cl-5.3, Table-2 (iv)(Manganese (as Mn)) |
- |
200 |
|
- |
| Cl-5.3, Table-2 (v)(Nitrate (as NO3 )) |
- |
200 |
|
- |
| Cl-5.3, Table-2 (vi)(Nitrite (as NO2 )) |
- |
200 |
|
- |
| Cl-5.3, Table-2 (vii)(Fluoride (as F)) |
- |
200 |
|
- |
| Cl-5.3, Table-2 (viii)(Zinc (as Zn)) |
- |
200 |
|
- |
| Cl-5.3, Table-2 (ix)(Silver (as Ag)) |
- |
200 |
|
- |
| Cl-5.3, Table-2 (x)(Aluminium (as A1)) |
- |
200 |
|
- |
| Cl-5.3, Table-2 (xi)(Chloride (as Cl)) |
- |
200 |
|
- |
| Cl-5.3, Table-2 (xii)(Selenium (as Se)) |
- |
200 |
|
- |
| Cl-5.3, Table-2 (xiii)(Sulphate (as SO4 )) |
- |
200 |
|
- |
| Cl-5.3, Table-2 (xiv)(Alkalinity (as HCO3 )) |
- |
200 |
|
- |
| Cl-5.3, Table-2 (xv)(Calcium (as Ca)) |
- |
200 |
|
- |
| Cl-5.3, Table-2 (xvi)(Magnesium (as Mg)) |
- |
200 |
|
- |
| Cl-5.3, Table-2 (xvii)(Sodium (as Na)) |
- |
200 |
|
- |
| Cl-5.3, Table-2 (xviii)(Residual free chlorine) |
- |
200 |
|
- |
| Cl-5.3, Table-2 (xix)(Phenolic compounds (as C6H5OH)) |
- |
200 |
|
- |
| Cl-5.3, Table-2 (xx)(Mineral oil) |
- |
550 |
|
- |
| Cl-5.2.1(Escherichia coli or thermotolerant bacteria) |
- |
415 |
|
- |
| Cl-5.2.2(Coliform) |
- |
415 |
|
- |
| Cl-5.2.3(Staphylococcus aureus) |
- |
470 |
|
- |
| Cl-5.2.4(Sulphite Reducing Anaerobes) |
- |
415 |
|
- |
| Cl-5.2.5(Pseudomonas Aeruginosa) |
- |
415 |
|
- |
| Cl-5.2.6(Aerobic Microbial Count @ 37 deg C) |
- |
415 |
|
- |
| Cl-5.2.7(Yeast and mould) |
- |
415 |
|
- |
| Cl-5.2.8(Salmonella) |
- |
415 |
|
- |
| Cl-5.2.9(Vibrio cholera) |
- |
415 |
|
- |
| Cl-5.1(General Requirements) |
- |
200 |
|
- |
| 5.4 i)(Dieldrin) |
- |
180 |
|
- |
| 5.4 i)(Aldrin) |
- |
180 |
|
- |
| 5.4 i)(Malathion) |
- |
180 |
|
- |
| 5.4, i)("oxygen analogue of Malathion (Malaoxon)") |
- |
180 |
|
- |
| 5.4 i)(Methyl Paraoxon) |
- |
180 |
|
- |
| 5.4 i)(Methyl Parathion) |
- |
180 |
|
- |
| 5.4 i)(Atrazine) |
- |
180 |
|
- |
| 5.4 i)(Alachlor) |
- |
180 |
|
- |
| 5.4 i)(Isoproturon) |
- |
180 |
|
- |
| 5.4 i)(Butachlor) |
- |
180 |
|
- |
| 5.4 i)(2,4-D) |
- |
180 |
|
- |
| 5.4 i)(Phorate sulphone) |
- |
180 |
|
- |
| 5.4 i)(Phorate sulphoxide) |
- |
180 |
|
- |
| 5.4 i)(Phorate) |
- |
180 |
|
- |
| 5.4 i)(Chlorpyrifos) |
- |
180 |
|
- |
| 5.4 i)(Ethion) |
- |
180 |
|
- |
| 5.4 i)(Monocrotophos) |
- |
180 |
|
- |
| 5.4 i)(Endosulfan Sulphate) |
- |
180 |
|
- |
| 5.4 i)(beta-Endosulfan) |
- |
180 |
|
- |
| 5.4 i)(alpha-Endosulfan) |
- |
180 |
|
- |
| 5.4 i)(Delta-HCH) |
- |
180 |
|
- |
| 5.4 i)(beta-HCH) |
- |
180 |
|
- |
| 5.4 i)(alpha-HCH) |
- |
180 |
|
- |
| 5.4 i)(Gamma-HCH (Lindane)) |
- |
180 |
|
- |
| 5.4 i)(p,p DDD) |
- |
180 |
|
- |
| 5.4 i)(o,p DDD) |
- |
180 |
|
- |
| 5.4 i)(p,p DDE) |
- |
180 |
|
- |
| 5.4, i)(o,p DDE) |
- |
180 |
|
- |
| 5.4 i)(p,p DDT) |
- |
180 |
|
- |
| 5.4 i)(o,p DDT) |
- |
180 |
|
- |
| Table 3, x)(Uranium) |
- |
200 |
|
- |
| Cl-5.3, Table-3 (x)(Uranium) |
- |
200 |
|
- |
| Cl-5.2.3(Faecal streptococci) |
- |
415 |
|
- |
| Cl-5.2.8(shigella) |
- |
415 |
|
- |
| Cl-5.2.9(V.parahaemolyticus) |
- |
415 |
|
- |
| 5.2.6(Aerobic Microbial Count @ 20 to 22 deg C) |
- |
415 |
|
- |
| Cl-5.3, Table-2 (xxi)(Anionic surface active agents) |
- |
200 |
|
- |
| Cl-5.3, Table-2 (xxii)(Sulphide) |
- |
200 |
|
- |
| Cl-5.3, Table-2 (xxiii)(Antimony (as Sb)) |
- |
200 |
|
- |
| Cl-5.3, Table-2 (xxiv)(Borates (as B)) |
- |
200 |
|
- |
| Cl-5.3, Table-2 (xxv)(Bromates (as BrO3 )) |
- |
200 |
|
- |
| Cl-5.3, Table-3 (i)(Mercury (as Hg)) |
- |
200 |
|
- |
| Cl-5.3, Table-3 (ii)(Cadmium (as Cd)) |
- |
200 |
|
- |
| Cl-5.3, Table-3 (iii)(Arsenic (as As)) |
- |
200 |
|
- |
| Cl-5.3, Table-3 (iv)(Cyanide (as CN)) |
- |
200 |
|
- |
| Cl-5.3, Table-3 (v)(Lead (as Pb)) |
- |
200 |
|
- |
| Cl-5.3, Table-3 (vi)(Chromium (as Cr)) |
- |
200 |
|
- |
| Cl-5.3, Table-3 (viii)(Polychlorinated biphenyl (PCB)) |
- |
200 |
|
- |
| Cl-5.3, Table-3 (vii)(Nickel (as Ni)) |
- |
200 |
|
- |
| Cl-5.3, Table-3 (ix)(Polynuclear aromatic hydrocarbons) |
- |
200 |
|
- |
| Cl-5.4 (i)(Pesticide residues considered individually) |
- |
200 |
|
- |
| Cl-5.4 (ii)(Total pesticide residue) |
- |
200 |
|
- |
| Cl-5.3, Table-4 (i)(Alpha emitters, Becquerel (Bq/l)) |
- |
0.00 |
|
- |
| Cl-5.3, Table-4 (ii)(Beta emitters, Becquerel (Bq/l),) |
- |
0.00 |
|
- |
| 5.3(Appearance) |
- |
- |
|
- |
| 5.4/Annex D/i(P,P-DDT) |
- |
- |
|
- |
| 5.4/Annex D/ii(Lindane) |
- |
- |
|
- |
| 5.4/Annex D/iv(b-Endosulfan) |
- |
- |
|
- |
| 5.4/Annex D/xvi(Dieldrin) |
- |
- |
|
- |
| 5.4/Annex D/xvi(Aldrin) |
- |
- |
|
- |
| 5.4/Annex D/i(O,P-DDT) |
- |
- |
|
- |
| 5.4/Annex D/iv(a-Endosulfan) |
- |
- |
|
- |
| 5.4/Annex D/iii(d-HCH) |
- |
- |
|
- |
| 5.4/Annex D/i(O,P-DDD) |
- |
- |
|
- |
| 5.4/Annex D/i(P,P-DDE) |
- |
- |
|
- |
| 5.4/Annex D/i(O,P-DDE) |
- |
- |
|
- |
| 5.4/Annex D/iii(a-HCH) |
- |
- |
|
- |
| 5.4/Annex D/iii(β- HCH) |
- |
- |
|
- |
| 5.4/Annex D/iv(Endosulfan sulfate) |
- |
- |
|
- |
| 5.4/Annex D/i(P,P-DDD) |
- |
- |
|
- |
| 5.4/Annex D/xii(Alachlor) |
- |
- |
|
- |
| 5.4/Annex D/vii(Chlorpyrifos) |
- |
- |
|
- |
| 5.4/Annex D/x(Butachlor) |
- |
- |
|
- |
| 5.4/Annex D/vi(Ethion) |
- |
- |
|
- |
| 5.4/Annex D/xiv(Methyl parathion) |
- |
- |
|
- |
| 5.4/Annex D/xv(Malathion) |
- |
- |
|
- |
| 5.4/Annex D/viii(Phorate) |
- |
- |
|
- |
| 5.4/Annex D/v(Monochrotophos) |
- |
- |
|
- |
| 5.4/Annex D/xiii(Atrazine) |
- |
- |
|
- |
| 5.4/Annex D/viii(Phorate sulphoxide) |
- |
- |
|
- |
| 5.4/Annex D/viii(Phorate sulfone) |
- |
- |
|
- |
| 5.4/Annex D/xxvii(Methyl paraoxon) |
- |
- |
|
- |
| 5.4/Annex D/xxviii(Malaoxon) |
- |
- |
|
- |
| 5.4/Annex D/xi(Isoproturon) |
- |
- |
|
- |
| 5.4/Annex D/ix(2,4 –D) |
- |
- |
|
- |
| Cl-5.3, Table-1 (i)(Colour, true colour units, Max) |
- |
- |
|
- |
| Cl-5.3, Table-1 (ii)(Odour) |
- |
- |
|
- |
| Cl-5.3, Table-1 (iii)(Taste) |
- |
- |
|
- |
| Cl-5.3, Table-1 (iv)(Turbidity, nephelometric turbidity unit (NTU), Max) |
- |
- |
|
- |
| Cl-5.3, Table-1 (v)(Total dissolved solids, mg/l, Max) |
- |
- |
|
- |
| Cl-5.3, Table-1 (vi)(pH) |
- |
- |
|
- |
| Cl-5.3, Table-2 (i)(Barium (as Ba)) |
- |
- |
|
- |
| Cl-5.3, Table-2 (ii)(Copper (as Cu)) |
- |
- |
|
- |
| Cl-5.3, Table-2 (iii)(Iron (as Fe)) |
- |
- |
|
- |
| Cl-5.3, Table-2 (iv)(Manganese (as Mn)) |
- |
- |
|
- |
| Cl-5.3, Table-2 (v)(Nitrate (as NO3 )) |
- |
- |
|
- |
| Cl-5.3, Table-2 (vi)(Nitrite (as NO2 )) |
- |
- |
|
- |
| Cl-5.3, Table-2 (vii)(Fluoride (as F)) |
- |
- |
|
- |
| Cl-5.3, Table-2 (viii)(Zinc (as Zn)) |
- |
- |
|
- |
| Cl-5.3, Table-2 (ix)(Silver (as Ag)) |
- |
- |
|
- |
| Cl-5.3, Table-2 (x)(Aluminium (as A1)) |
- |
- |
|
- |
| Cl-5.3, Table-2 (xi)(Chloride (as Cl)) |
- |
- |
|
- |
| Cl-5.3, Table-2 (xii)(Selenium (as Se)) |
- |
- |
|
- |
| Cl-5.3, Table-2 (xiii)(Sulphate (as SO4 )) |
- |
- |
|
- |
| Cl-5.3, Table-2 (xiv)(Alkalinity (as HCO3 )) |
- |
- |
|
- |
| Cl-5.3, Table-2 (xv)(Calcium (as Ca)) |
- |
- |
|
- |
| Cl-5.3, Table-2 (xvi)(Magnesium (as Mg)) |
- |
- |
|
- |
| Cl-5.3, Table-2 (xvii)(Sodium (as Na)) |
- |
- |
|
- |
| Cl-5.3, Table-2 (xviii)(Residual free chlorine) |
- |
- |
|
- |
| Cl-5.3, Table-2 (xix)(Phenolic compounds (as C6H5OH)) |
- |
- |
|
- |
| Cl-5.3, Table-2 (xx)(Mineral oil) |
- |
- |
|
- |
| Cl-5.2.1(Escherichia coli or thermotolerant bacteria) |
- |
- |
|
- |
| Cl-5.2.2(Coliform) |
- |
- |
|
- |
| Cl-5.2.3(Staphylococcus aureus) |
- |
- |
|
- |
| Cl-5.2.4(Sulphite Reducing Anaerobes) |
- |
- |
|
- |
| Cl-5.2.5(Pseudomonas Aeruginosa) |
- |
- |
|
- |
| Cl-5.2.6(Aerobic Microbial Count @ 37 deg C) |
- |
- |
|
- |
| Cl-5.2.7(Yeast and mould) |
- |
- |
|
- |
| Cl-5.2.8(Salmonella) |
- |
- |
|
- |
| Cl-5.2.9(Vibrio cholera) |
- |
- |
|
- |
| Cl-5.1(General Requirements) |
- |
- |
|
- |
| 5.4 i)(Dieldrin) |
- |
- |
|
- |
| 5.4 i)(Aldrin) |
- |
- |
|
- |
| 5.4 i)(Malathion) |
- |
- |
|
- |
| 5.4, i)("oxygen analogue of Malathion (Malaoxon)") |
- |
- |
|
- |
| 5.4 i)(Methyl Paraoxon) |
- |
- |
|
- |
| 5.4 i)(Methyl Parathion) |
- |
- |
|
- |
| 5.4 i)(Atrazine) |
- |
- |
|
- |
| 5.4 i)(Alachlor) |
- |
- |
|
- |
| 5.4 i)(Isoproturon) |
- |
- |
|
- |
| 5.4 i)(Butachlor) |
- |
- |
|
- |
| 5.4 i)(2,4-D) |
- |
- |
|
- |
| 5.4 i)(Phorate sulphone) |
- |
- |
|
- |
| 5.4 i)(Phorate sulphoxide) |
- |
- |
|
- |
| 5.4 i)(Phorate) |
- |
- |
|
- |
| 5.4 i)(Chlorpyrifos) |
- |
- |
|
- |
| 5.4 i)(Ethion) |
- |
- |
|
- |
| 5.4 i)(Monocrotophos) |
- |
- |
|
- |
| 5.4 i)(Endosulfan Sulphate) |
- |
- |
|
- |
| 5.4 i)(beta-Endosulfan) |
- |
- |
|
- |
| 5.4 i)(alpha-Endosulfan) |
- |
- |
|
- |
| 5.4 i)(Delta-HCH) |
- |
- |
|
- |
| 5.4 i)(beta-HCH) |
- |
- |
|
- |
| 5.4 i)(alpha-HCH) |
- |
- |
|
- |
| 5.4 i)(Gamma-HCH (Lindane)) |
- |
- |
|
- |
| 5.4 i)(p,p DDD) |
- |
- |
|
- |
| 5.4 i)(o,p DDD) |
- |
- |
|
- |
| 5.4 i)(p,p DDE) |
- |
- |
|
- |
| 5.4, i)(o,p DDE) |
- |
- |
|
- |
| 5.4 i)(p,p DDT) |
- |
- |
|
- |
| 5.4 i)(o,p DDT) |
- |
- |
|
- |
| Table 3, x)(Uranium) |
- |
- |
|
- |
| Cl-5.3, Table-3 (x)(Uranium) |
- |
- |
|
- |
| Cl-5.2.3(Faecal streptococci) |
- |
- |
|
- |
| Cl-5.2.8(shigella) |
- |
- |
|
- |
| Cl-5.2.9(V.parahaemolyticus) |
- |
- |
|
- |
| 5.2.6(Aerobic Microbial Count @ 20 to 22 deg C) |
- |
- |
|
- |
| Cl-5.3, Table-2 (xxi)(Anionic surface active agents) |
- |
- |
|
- |
| Cl-5.3, Table-2 (xxii)(Sulphide) |
- |
- |
|
- |
| Cl-5.3, Table-2 (xxiii)(Antimony (as Sb)) |
- |
- |
|
- |
| Cl-5.3, Table-2 (xxiv)(Borates (as B)) |
- |
- |
|
- |
| Cl-5.3, Table-2 (xxv)(Bromates (as BrO3 )) |
- |
- |
|
- |
| Cl-5.3, Table-3 (i)(Mercury (as Hg)) |
- |
- |
|
- |
| Cl-5.3, Table-3 (ii)(Cadmium (as Cd)) |
- |
- |
|
- |
| Cl-5.3, Table-3 (iii)(Arsenic (as As)) |
- |
- |
|
- |
| Cl-5.3, Table-3 (iv)(Cyanide (as CN)) |
- |
- |
|
- |
| Cl-5.3, Table-3 (v)(Lead (as Pb)) |
- |
- |
|
- |
| Cl-5.3, Table-3 (vi)(Chromium (as Cr)) |
- |
- |
|
- |
| Cl-5.3, Table-3 (viii)(Polychlorinated biphenyl (PCB)) |
- |
- |
|
- |
| Cl-5.3, Table-3 (vii)(Nickel (as Ni)) |
- |
- |
|
- |
| Cl-5.3, Table-3 (ix)(Polynuclear aromatic hydrocarbons) |
- |
- |
|
- |
| Cl-5.4 (i)(Pesticide residues considered individually) |
- |
- |
|
- |
| Cl-5.4 (ii)(Total pesticide residue) |
- |
- |
|
- |
| Cl-5.3, Table-4 (i)(Alpha emitters, Becquerel (Bq/l)) |
- |
- |
|
- |
| Cl-5.3, Table-4 (ii)(Beta emitters, Becquerel (Bq/l),) |
- |
- |
|
- |
| 5.3/Table 2/xiii(Suphate) |
- |
- |
|
- |
|
21 Apr, 2028 |
- Included w.e.f.16.04.2025
Exclusion
Cl-5.3, Table-4 (i) (Alpha emitters, Becquerel (Bq/l))
Cl-5.3, Table-4 (ii) (Beta emitters, Becquerel (Bq/l),) |