9211 |
MSME Testing Centre, New Delhi
| IS 204 : Part 2 (1992) |
Tower bolts - Specification: Part 2 non - Ferrous metals (Fifth Revision) |
- |
-
|
4800 View breakup
Rs.4800/- (10% concession for BIS)
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
6.1- Table 1(Dimension of Barrel tower bolts-1.Size 2.Length of Bolt or Barrel-(A or B) 4.Width of Barrel-C 5.Dia of Bolt-D 6.Length of Socket-E 7.Thickness of Metal of Barrel (Brass or Zink Alloy/Aluminium alloy/Sheet Brass)-F 8.Dia of bore of barrel or socket- G ) |
- |
4500 |
|
- |
5.1(General) |
- |
300 |
|
- |
5.2.1 Table 1(Particulars-Barrel Tower Bolts) |
- |
300 |
|
- |
5.2.2 Table 2(Particulars-Skeleton Tower Bolts) |
- |
300 |
|
- |
6.1- Table 1(Dimension of barrel tower bolts-Minimum No. of equally Spaced holes in Barrel & Socket for wooden screw no 6) |
- |
300 |
|
- |
6.2- Table 2(Dimension of Skeleton Tower Bolts 1.Size 2.Length of Bolt -A 3.Length of Bolt Plate -B 4.Width of Bolt Plate or Staple-C 5.Dia of Bolt-D 6.Length of Staple-E 7.Thickness of Plate or Socket (Brass /Aluminium alloy or Zink Alloy)-F 8.Dia of bore of Plate or Staple-G 9.Dia of shank of Knob ) |
- |
300 |
|
- |
6.2- Table 2(Dimension of Skeleton Tower Bolts- Nos of Staples) |
- |
300 |
|
- |
6.2- Table 2(Dimension of Skeleton Tower Bolts-Minimum No. of Screw holes for wood screw no 4) |
- |
300 |
|
- |
6.2- Table 3(PACKING) |
- |
300 |
|
- |
|
Complete
|
|
31 Dec, 2026 |
- - |
9212 |
MSME Testing Centre, New Delhi
| IS 205 (1992) |
Non - Ferrous metal butt specification (Fourth Revision) |
- |
-
|
4500 View breakup
Rs.4500/- (10% concession for BIS)
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
5.1- Table 2,3,4,5 & Fig-1 & 2(Dimensions- Type of Hinge 1.Length 2.Breadth 3.Butt Dia 4.Pin Dia 5.Thickness of Flap) |
- |
2400 |
|
- |
5.1- Table 2,3,4,5 & Fig-1 & 2(Dimensions- 1. Holes for Screw Desination 2. No. of screw Holes) |
- |
600 |
|
- |
6.1(Manufacture- General) |
- |
300 |
|
- |
6.2- Table 2,3,4,5 (Kunckles) |
- |
300 |
|
- |
6.3.1- Table 2,3,4,5 & Fig-1 & 2(Screw Holes) |
- |
300 |
|
- |
6.3.2- Table 2,3,4,5 (Number of Holes) |
- |
300 |
|
- |
6.3.3 Fig-1(Position of Holes) |
- |
300 |
|
- |
8.1(Packing - Each hinge shall be packed in card board boxes or in any other approved packing. The number of hinges in a package shall be as under) |
- |
300 |
|
- |
|
Complete
|
|
31 Dec, 2026 |
- - |
9213 |
MSME Testing Centre, New Delhi
| IS 285 (1992) |
Laundry soaps - Specification (Third Revision) |
- |
-
|
13650 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
5.4, Table-1 (ix) Type-2 (Built soap) Gr-2(LSD/NSD content, IS 4955) |
- |
1050 |
|
- |
5.4, Table-1 (viii) Type-2 (Built soap) Gr-1 & Gr-2(Chloride (as sodium chloride), IS 286) |
- |
950 |
|
- |
5.4, Table-1 (viii) Type-1 (Pure soap)(Chloride (as sodium chloride), IS 286) |
- |
950 |
|
- |
5.4, Table-1 (vii) Type-1 (Pure soap)(Glycerol, IS 286) |
- |
1050 |
|
- |
5.4, Table-1 (vi) Type-1 (Pure soap)(Titre of total fatty acids, IS 286) |
- |
1350 |
|
- |
5.4, Table-1 (v) Type-2 (Built soap) Gr-1(Matter insoluble in alcohol, IS 286) |
- |
1050 |
|
- |
5.4, Table-1 (iv) (Free caustic alkali, as sodium hydroxide (NaOH), IS 286) |
- |
950 |
|
- |
5.4, Table-1 (iii) (Unsaponified fatty matter, IS 286) |
- |
1050 |
|
- |
5.4, Table-1 (ii) (Rosin acids, percent by mass of total fatty matter, IS 286 ) |
- |
1050 |
|
- |
5.4, Table-1 (i) Type-2 (Built soap) Gr-2(Total fatty matter, IS 286) |
- |
1350 |
|
- |
5.3(Odour and Lathering Properties, IS 286) |
- |
500 |
|
- |
5.1.1(Phenolic substances, IS 286) |
- |
950 |
|
- |
|
Complete
|
|
31 Dec, 2026 |
- - |
9214 |
Bharat Test House Pvt Ltd 1474 Haryana
| IS 302 : Part 2 : Sec 202 (1992) |
Safety of household and similar electrical appliances: Part 2 particular requirements: Sec 202 electric stoves |
Electric stoves |
-
|
2275 View breakup
Rs.2275/-
(5% discount for
BIS)
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
6(Classification- IS 302-1 ) |
- |
0 |
|
- |
7.1(Marking- IS 302-1) |
- |
5 |
|
5% discount for BIS |
7.3(Marking- IS 302-1) |
- |
5 |
|
5% discount for BIS |
7.4(Marking- IS 302-1) |
- |
5 |
|
5% discount for BIS |
7.6(Marking- IS 302-1) |
- |
5 |
|
5% discount for BIS |
7.11(Marking- IS 302-1) |
- |
5 |
|
5% discount for BIS |
7.12(Marking- IS 302-1) |
- |
5 |
|
5% discount for BIS |
7.13(Marking- IS 302-1) |
- |
5 |
|
5% discount for BIS |
7.14(Marking- IS 302-1) |
- |
5 |
|
5% discount for BIS |
7.15(Marking- IS 302-1) |
- |
5 |
|
5% discount for BIS |
7.101(Marking) |
- |
5 |
|
5% discount for BIS |
8( Protection Against Electric Shock, IS 302-1) |
- |
150 |
|
5% discount for BIS |
10(Power Input and Current, IS 302-1) |
- |
100 |
|
5% discount for BIS |
11(Heating, IS 302-1) |
- |
250 |
|
5% discount for BIS |
13(Electrical Insulation and Leakage Current at Operating Temperature: Leakage current, IS 302-1) |
- |
100 |
|
5% discount for BIS |
15.1(Moisture Resistance, IS 302-1) |
- |
125 |
|
5% discount for BIS |
15.3(Moisture Resistance, IS 302-1) |
- |
125 |
|
5% discount for BIS |
16(Electrical Insulation and Leakage Current at Operating Temperature: Leakage current, IS 302-1) |
- |
50 |
|
5% discount for BIS |
16(Electrical Insulation and Leakage Current at Operating Temperature: High Voltage, IS 302-1) |
- |
50 |
|
5% discount for BIS |
19.2(Abnormal Operation, IS 302-1) |
- |
125 |
|
5% discount for BIS |
19.3(Abnormal Operation, IS 302-1) |
- |
125 |
|
5% discount for BIS |
20.1(Stability & Mechanical Hazards, IS 302-1) |
- |
150 |
|
5% discount for BIS |
21.1(Mechanical Strength, IS 302-1 & IS 302-2-202) |
- |
50 |
|
5% discount for BIS |
22(Construction, IS 302-1) |
- |
6 |
|
5% discount for BIS |
22.101(Construction) |
- |
6 |
|
5% discount for BIS |
22.102(Construction) |
- |
6 |
|
5% discount for BIS |
22.103(Construction) |
- |
6 |
|
5% discount for BIS |
22.104(Construction) |
- |
6 |
|
5% discount for BIS |
22.105(Construction) |
- |
6 |
|
5% discount for BIS |
22.106(Construction) |
- |
6 |
|
5% discount for BIS |
22.107(Construction) |
- |
6 |
|
5% discount for BIS |
23.1(Internal Wiring, IS 302-1) |
- |
10 |
|
5% discount for BIS |
23.2(Internal Wiring, IS 302-1) |
- |
10 |
|
5% discount for BIS |
23.8(Internal Wiring, IS 302-1) |
- |
10 |
|
5% discount for BIS |
23.9(Internal Wiring, IS 302-1) |
- |
10 |
|
5% discount for BIS |
23.10(Internal Wiring, IS 302-1) |
- |
10 |
|
5% discount for BIS |
25.1(Supply Connection and External Flexible Cords, IS 302-1) |
- |
25 |
|
5% discount for BIS |
25.2(Supply Connection and External Flexible Cords, IS 302-1) |
- |
25 |
|
5% discount for BIS |
26(Terminals for External Conductors, IS 302-1) |
- |
50 |
|
5% discount for BIS |
27.1(Provision for Earthing, IS 302-1) |
- |
10 |
|
5% discount for BIS |
27.2(Provision for Earthing, IS 302-1) |
- |
10 |
|
5% discount for BIS |
27.3(Provision for Earthing, IS 302-1) |
- |
10 |
|
5% discount for BIS |
27.4(Provision for Earthing, IS 302-1) |
- |
10 |
|
5% discount for BIS |
27.5(Provision for Earthing, IS 302-1) |
- |
10 |
|
5% discount for BIS |
28(Screws & Connections, IS 302-1) |
- |
50 |
|
5% discount for BIS |
29.1(Clearances, Creepage distances and Solid Insulation, IS 302-1) |
- |
25 |
|
5% discount for BIS |
29.2(Clearances, Creepage distances and Solid Insulation, IS 302-1) |
- |
25 |
|
5% discount for BIS |
30.1(Resistance to Heat, Fire & Tracking, IS 302-1) |
- |
88 |
|
5% discount for BIS |
30.2(Resistance to Heat, Fire & Tracking, IS 302-1) |
- |
88 |
|
5% discount for BIS |
31(Resistance of Rusting, IS 302-1) |
- |
100 |
|
5% discount for BIS |
|
Complete
|
|
19 Mar, 2026 |
- - |
9215 |
Central Power Research Institute (CPRI), Bangalore
| IS 398 : Part 5 (1992) |
Aluminium conductor for overhead transmission purposes - Specification: Part 5 aluminium conductors - Galvanized steel - Reinforced for extra high voltage (400 KV And Above) (First Revision) |
- |
-
|
85000 View breakup
Nominal Al area 500mm2 to 690mm2 – Rs. 1,82,680/-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
13.2 (mech)(Visual Examination) |
- |
850 |
|
PER CONDUCTOR |
13.3 Table-1 (mech)(Diameter-Aluminium wires) |
- |
850 |
|
PER CONDUCTOR |
13.5.1 Table 3 (elec)(Breaking Load on Complete conductor) |
- |
3100 |
|
PER WIRE / LAYER |
13.3 Table-2 (mech)(Diameter-Galvanized Steel wires) |
- |
850 |
|
PER CONDUCTOR |
13.5.2 Table 1 (mech)(Breaking Load of Aluminium Wires Before Stranding) |
- |
3100 |
|
PER WIRE / LAYER |
13.5.2 Table 2 (mech)(Breaking Load of Steel Wires Before Stranding) |
- |
3100 |
|
PER WIRE / LAYER |
13.6.1 (mech)(Ductility by Torsion Test before stranding) |
- |
2300 |
|
PER WIRE / LAYER |
|
Complete
|
|
31 Dec, 2026 |
- - |
9216 |
National Metallurgical Laboratory Unit
| IS 739 (1992) |
Wrought aluminium and aluminium alloys - Wire for general engineering purposes - Specification (Third Revision) |
- |
-
|
- View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
No Record Found
|
|
Complete
|
|
- |
- (Lab of national repute and eminence, facilities of which are being utilized by BIS.) |
9217 |
MSME Testing Centre, New Delhi
| IS 1746 (1992) |
Shoe polish, paste - Specification (Third Revision) |
- |
-
|
13050 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
4.1.1(Odour) |
- |
850 |
|
- |
4.1.2(Colour) |
- |
850 |
|
- |
4.1.3(Consistency) |
- |
850 |
|
- |
4.1.4(Applicability) |
- |
850 |
|
- |
4.1.6(colour of water extract) |
- |
850 |
|
- |
4.2 (table 1 S.no(i))(Softeing point of non-volatile matter) |
- |
850 |
|
- |
4.2 (table 1 S.no(ii))(Ash of the non-volatile matter) |
- |
850 |
|
- |
4.2 (table 1 S.no(iii))(pH of water extract
) |
- |
850 |
|
- |
4.2 (table 1 S.no(iv))(Distillation range of
volatile portion
) |
- |
850 |
|
- |
4.2 (table 1 S.no(v))(Flash point of volatile portion,) |
- |
850 |
|
- |
4.2 (table 1 S.no(vi))(Non-volatile matter
) |
- |
850 |
|
- |
|
Complete
|
|
31 Dec, 2026 |
- - |
9218 |
MSME Testing Centre, New Delhi
| IS 2074 (2015) |
Ready mixed paint, air drying, red oxide - Zinc chrome, priming - Specification (Third Revision) |
- |
-
|
9500 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
Cl 5.1 (a)(Composition, Pigment, Cl 5.1.1) |
- |
500 |
|
- |
Cl 5.1 (b)(Composition, Driers) |
- |
500 |
|
- |
Cl 5.1 .1 (a)(Zinc chrome, (Type 2 of
IS 51), Annex B) |
- |
500 |
|
- |
Cl 5.1 .1 (b)(Synthetic red oxides of iron (conforming to Grade 2 or
IS 44), (conforming to Grade 3
of IS 44), 6 of IS 6947
(Part 2)) |
- |
500 |
|
- |
Cl 5.1 .1 (c)(Suitable extenders) |
- |
500 |
|
- |
Cl 5.1.2(Volatile vehicle) |
- |
500 |
|
- |
Cl 5.2(Material) |
- |
500 |
|
- |
Cl 5.3(Compatibility with Thinner, IS 1872) |
- |
500 |
|
- |
Cl 5.4(Freedom from Objectionable Impurities) |
- |
500 |
|
- |
Cl 5.5(Lead Restriction, IS 101(Part 8/Sec 5)) |
- |
1000 |
|
- |
1 (i) (a) Table 1(Consistency, Annex C) |
- |
500 |
|
- |
1 (i) (b) Table 1(Viscosity by ford cup No. 4, IS 101 (Part1/sec5)) |
- |
500 |
|
- |
1 (ii) Table 1(Mass, IS 101 (Part1/sec7)) |
- |
500 |
|
- |
1 (iii) (a) Table 1(Drying time, Surface Dry, IS 101 (Part3/sec1)) |
- |
500 |
|
- |
1 (iii) (b) Table 1(Drying time, Hard Dry, IS 101 (Part3/sec1)) |
- |
500 |
|
- |
1 (iv) (a) Table 1(Finish, IS 101 (Part3/sec4)) |
- |
500 |
|
- |
1 (iv) (b) Table 1(Gloss, IS 101 (Part4/sec4)) |
- |
500 |
|
- |
1 (v) Table 1(Fineness of grind, IS 101 (Part 3/Sec 5)) |
- |
500 |
|
- |
1 (vi) Table 1(Colour, IS 101 (Part 4/Sec 2)) |
- |
500 |
|
- |
1 (vii) (a) Table 1(Flexibility and adhesion: Bend test (with 6.25 mm dia mandrel and in type 1 apparatus), Clause 2 of IS 101 (Part 5/Sec 2)) |
- |
800 |
|
- |
1 (vii) (b) Table 1(Scratch hardness (load 1 000g), Clause 3 of IS 101 (Part 5/Sec 2)) |
- |
500 |
|
- |
1 (viii) Table 1(Flash point, IS 101 (Part l/Sec 6)) |
- |
500 |
|
- |
1 (ix) Table 1(Volume solids, IS 101 (Part 8/Sec 6)) |
- |
800 |
|
- |
1 (x) (a) Table 1(Resistance to humidity under condition of condensation: Resistance to humidity, Clause 2 of IS 101 (Part 6/Sec 1)) |
- |
2000 |
|
- |
1 (x) (b) Table 1(Resistance to humidity under condition of condensation: Resistance to sea water (applicable for marine paints only), Annex D) |
- |
2000 |
|
- |
1 (x) (c) Table 1(Resistance to humidity under condition of condensation: Resistance to salt spray, Annex E) |
- |
2000 |
|
- |
1 (xi) Table 1(Accelerated storage stability test, Annex F) |
- |
2000 |
|
- |
|
Complete
|
|
31 Dec, 2026 |
- - |
9219 |
MSME Testing Centre, New Delhi
| IS 5487 (1992) |
Metal polish, liquid - Specification (First Revision) |
- |
-
|
14700 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
4.8, Table-1 (vi) (Oleic acid content, IS 5487 ) |
- |
1500 |
|
- |
4.8, Table-1 (v) (Flash point (Abel), IS 1448 Part-20) |
- |
1000 |
|
- |
4.8, Table-1 (iv) (Cyanides, IS 5487) |
- |
1000 |
|
- |
4.8, Table-1 (iii) (Residue on 75miron IS Sieve, IS 5487) |
- |
1000 |
|
- |
4.8, Table-1 (ii) (Total ammonia (as NH3), IS 5487) |
- |
1000 |
|
- |
4.8, Table-1 (i) (Total solids (excluding oils and fatty matter), IS 5487) |
- |
1000 |
|
- |
4.7(Keeping Quality, IS 5487) |
- |
7000 |
|
- |
4.6(Acidity of the Aqueous Extract, IS 5487) |
- |
500 |
|
- |
4.5(Polishing Property, IS 5487) |
- |
500 |
|
- |
4.4(Stability, IS 5487) |
- |
500 |
|
- |
4.3(Consistency, IS 5487 ) |
- |
500 |
|
- |
|
Complete
|
|
31 Dec, 2026 |
- - |
9220 |
MSME Testing Centre, New Delhi
| IS 8978 (1992) |
Specification for electric instantaneous water heaters (Second Revision) |
0 |
-
|
15000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
Cl.8 of IS 302-2-35:2017(Protection Against Access To Live Parts) |
- |
2500 |
|
- |
Cl.10 of IS 302-2- 35:2011(Power Input & Current ) |
- |
2500 |
|
- |
Cl.11 of 302-2-35:2017(Heating : Temperature rise of test corner) |
- |
3000 |
|
- |
Cl.13 of IS 302-2-35:2017(Leakage Current & Electrical Strength at Operating Temperature ) |
- |
4000 |
|
- |
Cl.14 of IS 302-2-35:2017(Transient Over Voltages ) |
- |
2000 |
|
- |
Cl.15 of IS 302-2-35-2011(Moisture Resistance ) |
- |
4000 |
|
- |
Cl.16 of IS 302-2-35:2017(Leakage Current and Electric Strength (After Humidity)) |
- |
4000 |
|
- |
Cl.19 of IS 302-2-35:2017(Abnormal Operation) |
- |
4000 |
|
- |
Cl 22.26 ,Cl.22.28, Cl 22.29, Cl 22.30 , Cl 22.31, Cl 22.32 of
IS 302-1:2008(Construction : Supplymentry/ double / reinforced insulation for Class II/ Class III appliance ) |
- |
2000 |
|
- |
Cl.26 of IS 302-2-35:2017(Terminals for External Conductors) |
- |
2000 |
|
- |
Cl.27 of IS 302-2-35:2017(Provision for Earthing) |
- |
2000 |
|
- |
Cl.28 of IS 302-2-35:2017(Screws and Connections
) |
- |
2000 |
|
- |
Cl.30.1 of IS 302-1:2008(Resistance to Heat and Fire) |
- |
4000 |
|
- |
Cl.31 of IS 302-2-35: 2011(Resistance to Rusting
) |
- |
2500 |
|
- |
Cl.25 of IS 302-2-35:2017(Supply Connection & External Flexible Cords) |
- |
2500 |
|
- |
Cl.29 of IS 302-2-35:2017(Clearances, Creepage Distances and Solid Insulation) |
- |
2500 |
|
- |
Cl.12 of IS 8978 : 1992(Endurance) |
- |
4000 |
|
- |
|
Complete
|
|
31 Dec, 2026 |
- Excl: Cl.19.11.4.1 to Cl.19.11.4.7 (EMI/EMC Test) |
9221 |
Central Power Research Institute (CPRI), Bangalore
| IS 13314 (1992) |
Solid state inverters run from storage batteries - Specification |
SOLID STATE INVERTERS |
-
|
157000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
4(General requirements) |
- |
0 |
|
The complete test charges will be intimated at the time of issuing the proforma invoice. |
5(Technical requirements) |
- |
0 |
|
The complete test charges will be intimated at the time of issuing the proforma invoice. |
6(Marking) |
- |
0 |
|
The complete test charges will be intimated at the time of issuing the proforma invoice. |
7(Tests and performance requirements) |
- |
0 |
|
The complete test charges will be intimated at the time of issuing the proforma invoice. |
7.2(Type tests) |
- |
0 |
|
The complete test charges will be intimated at the time of issuing the proforma invoice. |
8(Packing) |
- |
0 |
|
The complete test charges will be intimated at the time of issuing the proforma invoice. |
9(Information to be supplied by the supplier) |
- |
0 |
|
The complete test charges will be intimated at the time of issuing the proforma invoice. |
|
Complete
|
|
31 Dec, 2026 |
- ISS included w.e.f. 23/7/2018 |
9222 |
CENTRAL INSTITUTE OF PETROCHEMICALS ENGINEERING AND TECHNOLOGY (CIPET):CSTS-BHOPAL
| IS 13410 (1992) |
Glass reinforced polyester sheet moulding compounds(Smc) - Specification |
- |
-
|
- View breakup
Rs.24825/-
(After 25% discount for BIS)
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
No Record Found
|
|
Complete
|
|
31 Dec, 2026 |
- For S1 & S2 grade only |
9223 |
national dairy development board
| IS 13690 (1992) |
Pasteurtzed butter - Specification |
- |
-
|
- View breakup
Rs.2300/- for Chemical parameters, Rs.2250/- for Microbiological parameters
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
No Record Found
|
|
Complete
|
|
- |
- (Lab of national repute and eminence, facilities of which are being utilized by BIS.) |
9224 |
Central Power Research Institute (CPRI), Bangalore
| IS 7098 : Part 3 (1993) |
Cross - Linked polyethylene insulated thermoplastic sheathed cables - Specification: Part 3 for working voltages from 66 kV up to and including 220 kV |
- |
-
|
3922000 View breakup
Type Test on single core XLPE Insulated PVC/PE Sheathed Cable of Voltage rating 66 kV with conductor cross sections up to and including 1000 sq.mm Rs. 775920 /- + 18 % GST
Type test on single core XLPE Insulated PVC/PE Sheathed cable of Voltage rating 66 kV with conductor cross sections above 1000 sq.mm up to and including 1600 sq.mm Rs 820680+ 18 % GST
Type test on Single core XLPE Insulated PVC/PE Sheathed cable of voltage rating 66 kV with conductor cross sections above 1600 sq.mm up to and including 2500 sq.mm Rs.946210 + 18 % GST
Type test on 3 Core XLPE Insulated PVC/PE Sheathed cable of voltage rating 66 kV rating Rs. 1005010 + 18 % GST Type test on XLPE Insulated PVC/PE Sheathed cable of Voltage rating 132 kV with conductor cross sections up and including 1000 sq.mm Rs.1687880 + 18 % GST
Type test on XLPE Insulated cable of voltage rating 132 kV with conductor cross sections above 1000 sq.mm up to and including 1600 sq.mm Rs. 1887920+ 18 % GST
Type test on XLPE Insulated cable of voltage rating 132 kV with conductor cross sections above 1600 Sq.mm Rs.2276000 + 18 % GST Type Test on XLPE Insulated PE/PVC Sheathed cable of voltage rating 220 kV with conductor cross section up to and including 1000 sq.mm Rs.2899640 /- + 18 % GST
Type test on XLPE Insulated PVC/PE Sheathed cable voltage rating 220 kV with conductor cross sections above 1000 sq.mm up to and including 1600 sq.mm, Rs. 3877180 /- 18 % GST
Type test on XLPE Insulated PVC/PE Sheathed cable voltage rating 220 kV conductor cross sections above 1600 sq.mm up to and including 2500 sq.mm, Rs. 4331790 /- + 18 % GST
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
4.1(CONDUCTOR) |
- |
0 |
|
The complete test charges applicable will be intimated through proforma invoice. |
5(INSULATION) |
- |
0 |
|
The complete test charges applicable will be intimated through proforma invoice. |
6(SCREENING) |
- |
0 |
|
The complete test charges applicable will be intimated through proforma invoice. |
7.1(MOISTURE BARRIER : Laminated Tape) |
- |
0 |
|
The complete test charges applicable will be intimated through proforma invoice. |
7.2(MOISTURE BARRIER : Lead Alloy Sheath) |
- |
0 |
|
The complete test charges applicable will be intimated through proforma invoice. |
7.3(MOISTURE BARRIER : Water Blocking Tape/Powder) |
- |
0 |
|
The complete test charges applicable will be intimated through proforma invoice. |
8.1(INNER SHEATH) |
- |
0 |
|
The complete test charges applicable will be intimated through proforma invoice. |
8.2(INNER SHEATH) |
- |
0 |
|
The complete test charges applicable will be intimated through proforma invoice. |
8.3(INNER SHEATH) |
- |
0 |
|
The complete test charges applicable will be intimated through proforma invoice. |
9.1(ARMOUR) |
- |
0 |
|
The complete test charges applicable will be intimated through proforma invoice. |
9.2(ARMOUR) |
- |
0 |
|
The complete test charges applicable will be intimated through proforma invoice. |
10.1(OUTER SHEATH) |
- |
0 |
|
The complete test charges applicable will be intimated through proforma invoice. |
10.2(OUTER SHEATH) |
- |
0 |
|
The complete test charges applicable will be intimated through proforma invoice. |
11.1(CONDUCTOR) |
- |
0 |
|
The complete test charges applicable will be intimated through proforma invoice. |
11.2(CONDUCTOR) |
- |
0 |
|
The complete test charges applicable will be intimated through proforma invoice. |
12.1(CONDUCTOR SCREENING ) |
- |
0 |
|
The complete test charges applicable will be intimated through proforma invoice. |
12.2(CONDUCTOR SCREENING ) |
- |
0 |
|
The complete test charges applicable will be intimated through proforma invoice. |
13.1(INSULATION) |
- |
0 |
|
The complete test charges applicable will be intimated through proforma invoice. |
13.2(INSULATION) |
- |
0 |
|
The complete test charges applicable will be intimated through proforma invoice. |
14.1(INSULATION SCREENING) |
- |
0 |
|
The complete test charges applicable will be intimated through proforma invoice. |
14.2.1(INSULATION SCREENING : Non-metallic Part) |
- |
0 |
|
The complete test charges applicable will be intimated through proforma invoice. |
14.2.2(INSULATION SCREENING : Non-metallic Part) |
- |
0 |
|
The complete test charges applicable will be intimated through proforma invoice. |
14.2.3(INSULATION SCREENING : Non-metallic Part) |
- |
0 |
|
The complete test charges applicable will be intimated through proforma invoice. |
14.3.1(INSULATION SCREENING : Metallic Part) |
- |
0 |
|
The complete test charges applicable will be intimated through proforma invoice. |
14.3.2(INSULATION SCREENING : Metallic Part) |
- |
0 |
|
The complete test charges applicable will be intimated through proforma invoice. |
14.3.3(INSULATION SCREENING : Metallic Part) |
- |
0 |
|
The complete test charges applicable will be intimated through proforma invoice. |
15.1(MOISTURE BARRIER) |
- |
0 |
|
The complete test charges applicable will be intimated through proforma invoice. |
15.2.1(Metallic Sheath) |
- |
0 |
|
The complete test charges applicable will be intimated through proforma invoice. |
15.2.2(Metallic Sheath) |
- |
0 |
|
The complete test charges applicable will be intimated through proforma invoice. |
16.1(INNER SHEATH) |
- |
0 |
|
The complete test charges applicable will be intimated through proforma invoice. |
16.2(INNER SHEATH) |
- |
0 |
|
The complete test charges applicable will be intimated through proforma invoice. |
17.1(ARMOUR) |
- |
0 |
|
The complete test charges applicable will be intimated through proforma invoice. |
17.2(ARMOUR) |
- |
0 |
|
The complete test charges applicable will be intimated through proforma invoice. |
17.3(ARMOUR) |
- |
0 |
|
The complete test charges applicable will be intimated through proforma invoice. |
17.4(ARMOUR) |
- |
0 |
|
The complete test charges applicable will be intimated through proforma invoice. |
17.5(ARMOUR) |
- |
0 |
|
The complete test charges applicable will be intimated through proforma invoice. |
18.1(OUTER SHEATH) |
- |
0 |
|
The complete test charges applicable will be intimated through proforma invoice. |
18.2(outer sheath colour) |
- |
0 |
|
The complete test charges applicable will be intimated through proforma invoice. |
18.3.1(Thickness of Outer Sheath : Unarmoured Cables) |
- |
2300 |
|
The complete test charges applicable will be intimated through proforma invoice. |
18.3.1(Thickness of Outer Sheath : armoured Cables) |
- |
2300 |
|
The complete test charges applicable will be intimated through proforma invoice. |
19.1 A) I)(Tests on conductor : Annealing test ( for copper )) |
- |
1450 |
|
The test charges is applicable for one core and if the number core increases, test charges will also increase proportionally.
The complete test charges applicable will be intimated through proforma invoice. |
19.1 A) II)(Tests on conductor : Resistance test) |
- |
2300 |
|
The test charges is applicable for one core and if the number core increases, test charges will also increase proportionally.
The complete test charges applicable will be intimated through proforma invoice. |
19.1 b) I)(Test for thickness and dimensions of insulation) |
- |
2300 |
|
The test charges is applicable for one core and if the number core increases, test charges will also increase proportionally.
The complete test charges applicable will be intimated through proforma invoice. |
19.1 b) II)(Tensile strength and elongation at break) |
- |
6200 |
|
The test charges is applicable for one core and if the number core increases, test charges will also increase proportionally.
The complete test charges applicable will be intimated through proforma invoice. |
19.1 b) III)(Thermal ageing in air oven) |
- |
5300 |
|
The complete test charges applicable will be intimated through proforma invoice. |
19.1 b) IV)(Hot set test) |
- |
2300 |
|
The test charges is applicable for one core and if the number core increases, test charges will also increase proportionally.
The complete test charges applicable will be intimated through proforma invoice. |
19.1 b) V)(Shrinkage test) |
- |
1000 |
|
The test charges is applicable for one core and if the number core increases, test charges will also increase proportionally.
The complete test charges applicable will be intimated through proforma invoice. |
20.3(Test for concentric metallic screen : Test for concentric copper wire) |
- |
4600 |
|
The complete test charges applicable will be intimated through proforma invoice. |
20.4(Test for concentric copper tape) |
- |
4600 |
|
The complete test charges applicable will be intimated through proforma invoice. |
20.5(Thickness of metallic sheath) |
- |
2300 |
|
The complete test charges applicable will be intimated through proforma invoice. |
20.6(Tests for armouring material : Dimensions) |
- |
2300 |
|
The complete test charges applicable will be intimated through proforma invoice. |
19.1 f) II)(Tests for armouring material : Tensile strength and elongation at break) |
- |
5300 |
|
The complete test charges applicable will be intimated through proforma invoice. |
Table 9, (Measurement of thickness) |
- |
2300 |
|
The test charges is applicable for one core and if the number core increases, test charges will also increase proportionally.
The complete test charges applicable will be intimated through proforma invoice. |
19.1 g)2) i)(PVC sheath : Tensile strength and elongation at break) |
- |
6200 |
|
The complete test charges applicable will be intimated through proforma invoice. |
19.1 g)2) iii)(PVC sheath : Loss of mass) |
- |
5300 |
|
The complete test charges applicable will be intimated through proforma invoice. |
19.1 g)2) v)(PVC sheath : Hot deformation test) |
- |
2200 |
|
The complete test charges applicable will be intimated through proforma invoice. |
19.1 g)2) vi)(PVC sheath : Shrinkage test) |
- |
1000 |
|
The complete test charges applicable will be intimated through proforma invoice. |
19.1 g)2) vii)(PVC sheath : Thermal stability) |
- |
3000 |
|
The complete test charges applicable will be intimated through proforma invoice. |
19.1 g)3) ii)(PE sheath : Tensile strength and elongation at break before and after ageing) |
- |
6200 |
|
The complete test charges applicable will be intimated through proforma invoice. |
19.1 g)3) iii)(PE sheath : Hot-detormation) |
- |
2200 |
|
The complete test charges applicable will be intimated through proforma invoice. |
20.7(Flammabihty test ( for PVC outer
sheathed cables only )) |
- |
1600 |
|
The complete test charges applicable will be intimated through proforma invoice. |
20.8.3(Water tightness test) |
- |
4400 |
|
The complete test charges applicable will be intimated through proforma invoice. |
20.9.1(Thermal ageing on complete cable sample) |
- |
5300 |
|
The complete test charges applicable will be intimated through proforma invoice. |
19.1 k) ii)(Tensile strength and elongation at breakfor insulation and outer sheath) |
- |
6200 |
|
The test charges is applicable for one core and if the number core increases, test charges will also increase proportionally.
The complete test charges applicable will be intimated through proforma invoice. |
20.2(Resistivity test for semi-conducting layer) |
- |
2300 |
|
The complete test charges applicable will be intimated through proforma invoice. |
20.11.1(Bending test followed by P D test) |
- |
12750 |
|
The complete test charges applicable will be intimated through proforma invoice. |
20.12, 20.18(Dielectric power factor and capacitance measurement at ambient temperature) |
- |
6900 |
|
The test charges will change with respect to voltage rating, cross section and number of cores of the cable,
The complete test charges applicable will be intimated through proforma invoice. |
20.13(Dielectric power factor measurement at elevated temperature) |
- |
8350 |
|
The test charges will change with respect to voltage rating, cross section and number of cores of the cable,
The complete test charges applicable will be intimated through proforma invoice. |
20.14.1(Load cycle test followed by P.D measurement) |
- |
271050 |
|
The test charges will change with respect to voltage rating, cross section and number of cores of the cable,
The complete test charges applicable will be intimated through proforma invoice. |
20.15(Impulse Voltage Test Followed by High Voltage Test) |
- |
35850 |
|
The test charges will change with respect to voltage rating, cross section and number of cores of the cable,
The complete test charges applicable will be intimated through proforma invoice. |
19.5(Check on Insulation Thickness Before the Electrical Type Tests) |
- |
2300 |
|
The test charges is applicable for one core and if the number core increases, test charges will also increase proportionally.
The complete test charges applicable will be intimated through proforma invoice. |
20.16.1(Test for Dimensions of Insulation : Insulation Thickness) |
- |
2300 |
|
The test charges is applicable for one core and if the number core increases, test charges will also increase proportionally.
The complete test charges applicable will be intimated through proforma invoice. |
20.16.2(Test for Dimensions of Insulation : Test for Eccentricity) |
- |
2300 |
|
The test charges is applicable for one core and if the number core increases, test charges will also increase proportionally.
The complete test charges applicable will be intimated through proforma invoice. |
20.16.3(Test for Dimensions of Insulation : Test for Ovality) |
- |
2300 |
|
The test charges is applicable for one core and if the number core increases, test charges will also increase proportionally.
The complete test charges applicable will be intimated through proforma invoice. |
20.17(High Voltage Test ( as Routine and
Acceptance Tests ) ) |
- |
35850 |
|
The test charges will change with respect to voltage rating, cross section and number of cores of the cable,
The complete test charges applicable will be intimated through proforma invoice. |
20.18(Measurement of Capacitance) |
- |
8350 |
|
The test charges will change with respect to voltage rating, cross section and number of cores of the cable,
The complete test charges applicable will be intimated through proforma invoice. |
15.4 (b)(Cold impact) |
- |
7600 |
|
The complete test charges applicable will be intimated through proforma invoice. |
|
Complete
|
|
31 Dec, 2026 |
- - |
9225 |
Central Power Research Institute (CPRI), Bangalore
| IS 13703 : Part 2 : Sec 1 (1993) |
Specification for low - Voltage fuses for voltages not exceeding 1000 v ac or1500vdc: Part 2 fuses for use by authorized persons Sec 1 supplementary requirements |
- |
-
|
- View breakup
Rs.70250/- upto 200 A;
Rs.76650/- upto 1000 A
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
No Record Found
|
|
Complete
|
|
31 Dec, 2026 |
- - |
9226 |
National Metallurgical Laboratory Unit
| IS 617 (1994) |
Cast aluminium and its alloys - Ingots and castings for general engineering purposes - Specification (Third Revision) |
- |
-
|
- View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
No Record Found
|
|
Complete
|
|
- |
- (Lab of national repute and eminence, facilities of which are being utilized by BIS.) |
9227 |
Fluid Control Research Institute
| IS 779 (1994) |
Water meters (Domestic Type) - Specification (Sixth Revision) |
- |
-
|
69500 View breakup
Type Test (Routine + Life cycle tests)
Rs. 59900/- for 15mm
Rs. 64800/- for 20mm
Rs. 72150/- for 25mm
Rs. 89010/- for 40mm
Rs. 101820/- for 50mm
Rs.9600/- for remaining tests
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
10.1(Pressure tightness) |
- |
1600 |
|
- |
10.2(Loss of pressure) |
- |
1600 |
|
- |
11.1(Metering Accuracy) |
- |
1600 |
|
- |
11.2(Min. Starting flow) |
- |
1600 |
|
- |
10.3(Temp. suitability ) |
- |
1600 |
|
- |
12.4.2(Construction) |
- |
1600 |
|
- |
12.4.4(Life test ) |
- |
59900 |
|
- |
|
Complete
|
|
- |
- Deferred w.e.f. 25.07.2024
Excluding Material test(Cl.6.1) |
9228 |
National Physical Laboratory
| IS 779 (1994) |
Water meters (Domestic Type) - Specification (Sixth Revision) |
- |
-
|
- View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
No Record Found
|
|
Complete
|
|
- |
- (Lab of national repute and eminence, facilities of which are being utilized by BIS.) |
9229 |
MSME Testing Centre, New Delhi
| IS 7231 (1994) |
plastic flushing cisterns for waterclosets and urinals |
- |
-
|
10400 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
Cl 5.1(Cistern) |
- |
600 |
|
- |
Cl 5.2(Cover) |
- |
300 |
|
- |
Cl 5.3(Flush pipe) |
- |
900 |
|
- |
Cl 5.3.1(Flush pipe connection to cistern.) |
- |
900 |
|
- |
Cl 5.4(Inlet and overflow holes) |
- |
900 |
|
- |
Cl 5.6(Operating mechanism / lever) |
- |
300 |
|
- |
Cl 5.7(String (Chain)) |
- |
300 |
|
- |
Cl 5.8(Overflow pipe) |
- |
300 |
|
- |
Cl 7.1(Flushing Arrangements) |
- |
300 |
|
- |
Cl 7.2(Working water level) |
- |
300 |
|
- |
Cl 7.3(Freedom from self-siphonage) |
- |
300 |
|
- |
Cl 7.4(Reduced water level) |
- |
300 |
|
- |
Cl 7.5(Discharge capacity) |
- |
300 |
|
- |
Cl 7.6 & 9.2(Discharge rate ) |
- |
1000 |
|
- |
Cl 8.1(Distortion resistance test) |
- |
500 |
|
- |
(Cl 8.2)(Dead load test) |
- |
500 |
|
- |
(Cl 8.3)(Front thrust test) |
- |
500 |
|
- |
(Cl 8.4)(Impact test) |
- |
500 |
|
- |
(Cl 9.3)(Endurance test) |
- |
1000 |
|
- |
(Cl.6)(Finish) |
- |
300 |
|
- |
|
Complete
|
|
31 Dec, 2026 |
- - |
9230 |
DEFENCE INSTITUTE OF FIRE RESEARCH
| IS 8423 (1994) |
Specification for controlled percolating hose for fire fighting |
- |
-
|
- View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
No Record Found
|
|
Complete
|
|
- |
- (Lab of national repute and eminence, facilities of which are being utilized by BIS.) |
9231 |
MSME Testing Centre, New Delhi
| IS 13983 (1994) |
Stainless Steel Sinks For Domestic Purposes |
- |
-
|
13300 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
9(Marking) |
- |
300 |
|
- |
4(Type) |
- |
300 |
|
- |
6(Thickness of sheet/strip) |
- |
300 |
|
- |
6(Depth of bowl) |
- |
300 |
|
- |
6(Internal dimensions of the bowl) |
- |
600 |
|
- |
6(Bowl locating limits) |
- |
600 |
|
- |
6(Co-ordinating sizes) |
- |
1800 |
|
- |
7.1(Consruction and workmanship) |
- |
300 |
|
- |
7.1.1(Consruction and workmanship) |
- |
300 |
|
- |
7.2(Consruction and workmanship) |
- |
300 |
|
- |
7.2.1(Consruction and workmanship) |
- |
300 |
|
- |
7.3(Drainers) |
- |
300 |
|
- |
7.4(Waste outlet) |
- |
300 |
|
- |
7.5(Tap holes) |
- |
300 |
|
- |
7.6(Overflows) |
- |
300 |
|
- |
8(Finish) |
- |
300 |
|
- |
|
Complete
|
|
31 Dec, 2026 |
- - |
9232 |
National Metallurgical Laboratory Unit
| IS 6527 (1995) |
Stainless steel wire rods - Specification (First Revision) |
- |
-
|
- View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
No Record Found
|
|
Complete
|
|
- |
- (Lab of national repute and eminence, facilities of which are being utilized by BIS.) |
9233 |
LPG Equipment Research Centre (LERC)
| IS 7142 (1995) |
Welded low carbon steel cylinders for low pressure liquifiable gases not exceeding 5 litre water capacity - Specification (First Revision) |
- |
-
|
- View breakup
Rs.16250/-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
No Record Found
|
|
Complete
|
|
- |
- Included w.e.f. 13-03-2020. (Lab of national repute and eminence, facilities of which are being utilized by BIS.) |
9234 |
Rajasthan Test & Research Centre
| IS 8783 : Part 4 : Sec 2 (1995) |
Winding wires for submersible motors - specification: Part 4 specification for individual wires: Sec 2 crosslinked polyethylene insulated and polyamide jacketed wires (First Revision) |
- |
-
|
- View breakup
(Provisional testing charges):
Rs.13,800.00
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
No Record Found
|
|
Complete
|
|
16 Aug, 2024 |
- - |
9235 |
Central Power Research Institute (CPRI), Bangalore
| IS 14255 (1995) |
Aertal bunched cables - For working voltages up to and including 1100 Volts - Specification |
- |
-
|
152550 View breakup
Rs.82000/- +18% GST (1ph + 1 bare mes); Rs.112000/- +18% GST (1ph + 1 ins. Mes); Rs.124000/- +18% GST ( 1 ph + 1 bare mes + 1 SL); Rs.151000/- +18% GST ( 1 ph + 1 ins. + 1 SL); Rs.108000 /- +18 % GST (2 Ph, 1 bare mes); Rs.133000 /- +18 % GST (2 Ph, 1 ins mes); Rs.141000 /- +18 % GST (2 Ph + 1 bare mes+1 SL); Rs.172000 /- +18 % GST (2 Ph + 1 ins mes+ 1SL); Rs.135000/- +18% GST (3ph + 1 bare mes); Rs.221000/- +18% GST (3ph + 1 ins. mes); Rs.174000/- (3ph + 1 bare mes + 1 SL); Rs.205000/- (3ph + 1 ins. Mes + 1 SL); Rs.202000/- (4ph + 1 Bare Mes + 1 SL); Rs.238000/- (4ph + 1 ins Mes + 1 SL)
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
4.1(Phase/Street Lighting conductor) |
- |
0 |
|
The complete test charges applicable will be intimated through proforma invoice. |
4.2(Messenger (Neutral Conductor or Otherwise)) |
- |
0 |
|
The complete test charges applicable will be intimated through proforma invoice. |
5.1(Insulation) |
- |
0 |
|
The complete test charges applicable will be intimated through proforma invoice. |
6.1(Flexibility class) |
- |
0 |
|
The complete test charges applicable will be intimated through proforma invoice. |
6.2(Compactness) |
- |
0 |
|
The complete test charges applicable will be intimated through proforma invoice. |
6.2(No of strands) |
- |
0 |
|
The complete test charges applicable will be intimated through proforma invoice. |
6.3(Protective barrier) |
- |
0 |
|
The complete test charges applicable will be intimated through proforma invoice. |
6.4(size of street lighting conductor) |
- |
0 |
|
The complete test charges applicable will be intimated through proforma invoice. |
6.5(Size of messenger conductor ) |
- |
0 |
|
The complete test charges applicable will be intimated through proforma invoice. |
6.6(Joints in messenger conductor ) |
- |
0 |
|
The complete test charges applicable will be intimated through proforma invoice. |
6.6(Direction of outer layer) |
- |
0 |
|
The complete test charges applicable will be intimated through proforma invoice. |
7.1(Insulation) |
- |
0 |
|
The complete test charges applicable will be intimated through proforma invoice. |
7.2( Thickness of insulation) |
- |
1600 |
|
The test charges is applicable for one core and if the number core increases, test charges will also increase proportionally.
The complete test charges applicable will be intimated through proforma invoice. |
7.3(Tolerance on thickness of insulation ) |
- |
0 |
|
The complete test charges applicable will be intimated through proforma invoice. |
7.4(Aplication of the insulation ) |
- |
0 |
|
The complete test charges applicable will be intimated through proforma invoice. |
7.5(Colour of the insulation ) |
- |
0 |
|
The complete test charges applicable will be intimated through proforma invoice. |
8.1(Core identification) |
- |
0 |
|
The complete test charges applicable will be intimated through proforma invoice. |
8.2(Core identification) |
- |
0 |
|
The complete test charges applicable will be intimated through proforma invoice. |
8.3(Identification by other means) |
- |
0 |
|
The complete test charges applicable will be intimated through proforma invoice. |
9.1(Assembly (Laying up)) |
- |
0 |
|
The complete test charges applicable will be intimated through proforma invoice. |
9.2(Assembly (Laying up)) |
- |
0 |
|
The complete test charges applicable will be intimated through proforma invoice. |
9.3(Direction of lay) |
- |
0 |
|
The complete test charges applicable will be intimated through proforma invoice. |
10.1 a) i)(Tests on phase/street light conductor: tensile test - Test method IS10810:Part 2) |
- |
5300 |
|
The test charges is applicable for one core and if the number core increases, test charges will also increase proportionally.
The complete test charges applicable will be intimated through proforma invoice. |
10.1 a) ii)(Wrapping test - 10810: Part 3) |
- |
500 |
|
The complete test charges applicable will be intimated through proforma invoice. |
10.1 a) iii)(Resistance test - IS10810: Part 5) |
- |
2300 |
|
The test charges is applicable for one core and if the number core increases, test charges will also increase proportionally.
The complete test charges applicable will be intimated through proforma invoice. |
10.1 b) i)(Test on messenger conductor: Breaking load - IS 10810: Part 2) |
- |
5300 |
|
The complete test charges applicable will be intimated through proforma invoice. |
10.1 b) ii)(Test on messenger conductor: Elongation test - Cl 11.3) |
- |
5300 |
|
The complete test charges applicable will be intimated through proforma invoice. |
10.1 b) iii)(Test on messenger conductor: Resistance test - IS 10810: Part 5) |
- |
2300 |
|
The complete test charges applicable will be intimated through proforma invoice. |
10.1 c) i)(Physical tests for XLPE Insulation:
Tensile strength - IS 10810: Part 7) |
- |
6200 |
|
The test charges is applicable for one core and if the number core increases, test charges will also increase proportionally.
The complete test charges applicable will be intimated through proforma invoice. |
10.1 c) i)(Physical tests for XLPE Insulation:
elongation at break - IS 10810: part 7) |
- |
6200 |
|
The test charges is applicable for one core and if the number core increases, test charges will also increase proportionally.
The complete test charges applicable will be intimated through proforma invoice. |
10.1 c) ii)(Ageing in air oven : Tensile strength variation - IS 10810:Part 11) |
- |
5300 |
|
The complete test charges applicable will be intimated through proforma invoice. |
10.1 c) ii)(Ageing in air oven : Elongation variation- IS 10810: Part 11) |
- |
0 |
|
The complete test charges applicable will be intimated through proforma invoice. |
10.1 c) iii)(Hot set test: Elongation under load - IS 10810: Part 30) |
- |
2300 |
|
The test charges is applicable for one core and if the number core increases, test charges will also increase proportionally.
The complete test charges applicable will be intimated through proforma invoice. |
10.1 c) iii)(Hot set test: Permanent elongation (set) after cooling - IS 10810: Part 30) |
- |
2300 |
|
The test charges is applicable for one core and if the number core increases, test charges will also increase proportionally.
The complete test charges applicable will be intimated through proforma invoice. |
10.1 c) iv)(Shrinkage test : Shrinkage - 10810:Part 12) |
- |
1000 |
|
The test charges is applicable for one core and if the number core increases, test charges will also increase proportionally.
The complete test charges applicable will be intimated through proforma invoice. |
10.1 c) iv)(Shrinkage test : Crack Observed - 10810:Part 12) |
- |
0 |
|
The test charges is applicable for one core and if the number core increases, test charges will also increase proportionally.
The complete test charges applicable will be intimated through proforma invoice. |
10.1 c) v)(Water ahsorption (Gravimetric) - IS 10810: Part 33 ) |
- |
16100 |
|
The complete test charges applicable will be intimated through proforma invoice. |
10.1 d) i)(Physical test for PE insulation:
Tensile strength - IS 10810: Part 7 ) |
- |
6200 |
|
The test charges is applicable for one core and if the number core increases, test charges will also increase proportionally.
The complete test charges applicable will be intimated through proforma invoice. |
10.1 d) i)(Physical test for PE insulation: elongation at break - IS 10810: Part 7) |
- |
6200 |
|
The test charges is applicable for one core and if the number core increases, test charges will also increase proportionally.
The complete test charges applicable will be intimated through proforma invoice. |
10.1 d) ii)(Melt flow index- IS 10810: Part 23) |
- |
0 |
|
The complete test charges applicable will be intimated through proforma invoice. |
10.1 d) iv)(Vicat softening point -IS 10810: Part 22) |
- |
2200 |
|
The test charges is applicable for one core and if the number core increases, test charges will also increase proportionally.
The complete test charges applicable will be intimated through proforma invoice. |
10.1 d) v)(Environmental stress cracking -IS 10810:Part29) |
- |
1000 |
|
The test charges is applicable for one core and if the number core increases, test charges will also increase proportionally.
The complete test charges applicable will be intimated through proforma invoice. |
10.1 f)(Insulation resistance (Volume resistivity) test a) volume resistivity at 27°C - IS 10810: Part 43) |
- |
1100 |
|
The test charges is applicable for one core and if the number core increases, test charges will also increase proportionally.
The complete test charges applicable will be intimated through proforma invoice. |
10.1 f)(Insulation resistance (Volume resistivity) test b) volume resistivity at 70°C - IS 10810: Part 43) |
- |
1700 |
|
The test charges is applicable for one core and if the number core increases, test charges will also increase proportionally.
The complete test charges applicable will be intimated through proforma invoice. |
10.1 g)(High voltage test - IS10810:Part 45) |
- |
1300 |
|
The test charges is applicable for one core and if the number core increases, test charges will also increase proportionally.
The complete test charges applicable will be intimated through proforma invoice. |
11.4(Bending Test on the Completed Cable ( Optional) ) |
- |
5700 |
|
The complete test charges applicable will be intimated through proforma invoice. |
|
Complete
|
|
31 Dec, 2026 |
- - |
9236 |
Central Institute of Fisheries Technology Cochin
| IS 14287 (1995) |
Textiles - Polypropylene multifilament netting twines - Specification |
- |
-
|
- View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
No Record Found
|
|
Complete
|
|
- |
- (Lab of national repute and eminence, facilities of which are being utilized by BIS.) |
9237 |
Indian Institute of Technology Chennai
| IS 325 (1996) |
Three-phase Induction Motors |
- |
-
|
- View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
No Record Found
|
|
Complete
|
|
- |
- (Lab of national repute and eminence, facilities of which are being utilized by BIS.) |
9238 |
Central Power Research Institute (CPRI), Bangalore
| IS 398 : Part 2 (1996) |
Aluminium conductors for overhead transmission purposes - Specification: Part 2 aluminium conuuctors, galvanized steel - Reinforced (Third Revision) |
- |
-
|
85000 View breakup
a. Nominal Al area 10mm2 to 80mm2 – Rs.34,500/- b. Nominal Al area 100mm2 Rs.1,91,250/- c. Nominal Al area 150mm2 to 200mm2 – Rs.2,16,550/- d. Nominal Al area 400mm2 to 560mm2 – Rs.2,43,000/-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
13.9 (elec)(Surface condition test) |
- |
21300 |
|
- |
13.10 (elec)(Ultimate breaking load) |
- |
52500 |
|
- |
13.8 Table-4 (mech)(Lay Ratio- Aluminium Wire Outermost Layer) |
- |
3100 |
|
PER WIRE / LAYER |
13.8 Table-4 (mech)(Lay Ratio- Aluminium Wire Layer Immediately Beneath Outermost Layer) |
- |
3100 |
|
PER WIRE / LAYER |
13.3 Table 1 (mech)(Breaking Load of Aluminium Wires Before Stranding) |
- |
3100 |
|
PER WIRE / LAYER |
13.3 Table 2 (mech)(Breaking Load of Steel Wires Before Stranding) |
- |
3100 |
|
PER WIRE / LAYER |
13.4.1 (mech)(Ductility by Torsion Test before stranding) |
- |
3100 |
|
PER WIRE / LAYER |
13.4.1 (mech)(Ductility by Torsion Test after stranding) |
- |
3100 |
|
PER WIRE / LAYER |
13.5.1 (mech)(Wrapping Test Aluminium Wires Before Stranding) |
- |
500 |
|
PER WIRE / LAYER |
13.7.2 (chem)(Mass of Zinc coating) |
- |
1400 |
|
PER WIRE / LAYER |
13.7.2 (chem)(Uniformity of Zinc coating) |
- |
1400 |
|
PER WIRE / LAYER |
13.11 (elec)(Stress-strain test) |
- |
2300 |
|
PER WIRE / LAYER |
|
Complete
|
|
31 Dec, 2026 |
- - |
9239 |
MSME Testing Centre, New Delhi
| IS 398 : Part 2 (1996) |
Aluminium conductors for overhead transmission purposes - Specification: Part 2 aluminium conuuctors, galvanized steel - Reinforced (Third Revision) |
- |
-
|
8276 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
13.4.1 (mech)(Ductility by Torsion Test before stranding) |
- |
1444 |
|
- |
13.4.1 (mech)(Ductility by Torsion Test after stranding) |
- |
1444 |
|
- |
13.5.1 (mech)(Wrapping Test Aluminium Wires Before Stranding) |
- |
1271 |
|
- |
13.5.1 (mech)(Wrapping Test Aluminium Wires After Stranding) |
- |
1271 |
|
- |
13.5.2 (mech)(Wrapping Test Galvanized Steel Wires Before Stranding) |
- |
1271 |
|
- |
13.5.2 (mech)(Wrapping Test Galvanized Steel Wires After Stranding) |
- |
1271 |
|
- |
13.6 (elec)(Resistance test-Aluminium wire before Stranding) |
- |
1652 |
|
- |
13.6 (elec)(Resistance test-Aluminium wire after stranding) |
- |
1652 |
|
- |
13.7.2 (chem)(Mass of Zinc coating) |
- |
1386 |
|
- |
13.7.2 (chem)(Uniformity of Zinc coating) |
- |
1386 |
|
- |
8.1.1 & 13.2 Table-1 (mech)(Diameter of Aluminium Wires Before Stranding) |
- |
559 |
|
Nominal Size |
13.3 Table 1 (mech)(Breaking Load of Aluminium Wires Before Stranding) |
- |
1444 |
|
- |
8.1.1 & 13.2 Table 2 (mech)(Diameter of Steel Wires Before Stranding) |
- |
559 |
|
Nominal Size |
8.1.1 & 13.2 Table-1 (mech)(Diameter of Aluminium Wires After Stranding) |
- |
559 |
|
Nominal Size |
8.1.1 & 13.2 Table 2 (mech)(Diameter of Steel Wires After Stranding) |
- |
559 |
|
Nominal Size |
13.3 Table 2 (mech)(Breaking Load of Steel Wires Before Stranding) |
- |
1444 |
|
- |
13.3 Table 1 (mech)(Breaking Load of Aluminium Wires After Stranding) |
- |
1444 |
|
- |
13.3 Table 2 (mech)(Breaking Load of Steel Wires After Stranding) |
- |
1444 |
|
- |
|
Complete
|
|
31 Dec, 2026 |
- - |
9240 |
Central Institute of Mining & Fuel Research, Dhanbad
| IS 3768 (1996) |
Ventilation ducting - Vinyl coated, flexible and semi - Rigid - Specification (Second Revision) |
- |
-
|
- View breakup
Rs.22,800/- per sample
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
No Record Found
|
|
Complete
|
|
- |
- Except coating adhesion and flex tests.(Lab of national repute and eminence, facilities of which are being utilized by BIS.) |