Search by IS Number
Reset
11324 Results
S.No. Lab Name Osl Code Indian Standard No. Product Grade / Type / Size / Designation etc. Testing Charges (Excl. Of Taxes) Validity Date Remark
10201 BIS, Central Laboratory (CL) None IS 398 : Part 2 (1996) Aluminium conductors for overhead transmission purposes - Specification: Part 2 aluminium conuuctors, galvanized steel - Reinforced (Third Revision) - - View breakup
(I) For galvanized steel core only (consisting of 7 steel strands)- Rs.2850.00, (II) For galvanized steel reinforced stranded conductors with nominal aluminium area upto and including 100mm2-(a) For single steel wire core (1 steel + 6 Aluminium)- Rs. 1950.00 (b) For 7 wire core (7 steel + 6 Aluminium) - Rs. 4000.00, (III) For galvanized steel reinforced stranded conductors with nominal aluminium area more than 100mm2 (excluding special tests as per Cl. 13.9, 13.10 & 13.11)-(a) For stranded conductors with 37 strands-Rs.7900/-, (b) For stranded conductors with 49 strands-Rs.10000/-, (c) For stranded conductors with 61 strands-Rs.11100/-,
- -
Complete upto 100 sqmm, Above 100 sq. mm. TF not available for Stress-strain test, Surface conditioning test, ultimate breaking load on stranded conductor
10202 BIS, Central Laboratory (CL) None IS 12592 (2002) Precast concrete manhole cover and frame - Specification (First Revision) - - View breakup
Rs 3000/- Excluding Load Test
- -
Excluding -; Load test
10203 Ace Test Labs & Metrology Pvt. Ltd. 9162826 IS 16102 : Part 1 (2012) Self - Ballasted led lamps for general lighting services: Part 1 safety requirements - 51000 View breakup
Rs.51000/- (10% discount for BIS)
14 Nov, 2027 -
Only for IP(0-4)(5-6) Restricted for B22d , and E14 , E 27 ( Included w.e.f. 27.08.2019) Upto 30 V and 10 A only
10204 BIS, Western Regional Laboratory (WRL) None IS 2002 (2009) Steel plate for pressure vessel for intermediate and high temperature service including boilers (Third Revision) - - View breakup
-
- -
Test facilities are not available for the following: 1. Al, N, Cu, Mn, Cr, Mo, V, Ni 3. Homogeneity test 3. Ultrasonic test, ( cl 15 )
10205 BIS, Central Laboratory (CL) None IS 1038 (1983) Specification For Steel Doors, Windows And Ventilators - - View breakup
Hence complete testing charges for the product are Rs.3000.00
- -
-
10206 BIS, Central Laboratory (CL) None IS 12427 (2001) Fasteners - Threaded steel fasteners - Hexagon head transmission tower bolts - Specification (First Revision) - - View breakup
Rs.11850/- Excluding Proof load, Head soundness wedge load and decarburization test.
- -
Excluding -; Cl 6 - Mechanical Properties as per IS 1367-3 (Except Hardness & Impact Test), Cl 6.2 - Shear Strength
10207 BIS, Central Laboratory (CL) None IS 7452 (1990) Hot rolled steel sections for doors, windows and ventilators - Specification - Rs 1800/- View breakup
-
- -
Sample size shall be minimum dia> 3mm and thickness > 0.8 mm;
10208 BIS, Northern Regional Laboratory (NRL) None IS 9968 : Part 1 (1988) Specification for elastomer insulatedcables: Part 1 for working voltages up to and including 1100 volts (First Revision) - Rs.12000/ View breakup
-
- -
Excluding Cl.21.1 water absorption test (electrical) for IE2
10209 BIS, Central Laboratory (CL) None IS 15030 (2001) Terephthalic acid - Specification - - View breakup
-
- -
Excluding Supersheded by IS 15030 ( 2022);
10210 BIS, Central Laboratory (CL) None IS 4454 : Part 2 (2001) Steel wire for mechanical springs - Specification february 2001: Part 2 oil hardened and tempered steel wire (Second Revision) - - View breakup
-
- -
Sample size shall be minimum dia> 3mm and thickness > 0.8 mm;
10211 BIS, Central Laboratory (CL) None IS 398 : Part 1 (1996) Aluminium conductors for overhead transmission purposes - Specification: Part 1 aluminium stranded conductors (Third Revision) - Rs.1600/- for 7 strands, Rs.3750/- for 19 strands View breakup
-
- -
-
10212 BIS, Central Laboratory (CL) None IS 2721 (2003) Galvanized steel chain link fence fabric - Specification (Second Revision) - - View breakup
Rs.5950/- (for wire below 5 mm Dia), Rs.6910/- (for wires above 5 mm Dia) and Material testing charges as per relevant referred Iss
- -
Sample size shall be minimum dia> 3mm and thickness > 0.8 mm;
10213 CIPET, Hyderabad 6111634 IS 710 (2010) Marine plywood - Specification (Second Revision) - 20050 View breakup
Rs.19675/-
23 Feb, 2027 -
Testing charges has been fixed for a period of two years w.e.f. 29.01.2019 i.e. up to 28.01.2021.
10214 BIS, Eastern Regional Laboratory (ERL) None IS 210 (2009) Grey iron castings - Specification (First Revision) For all grades except tests mentioned in remarks Rs.2700.00 View breakup
-
- -
Chem: only available for Phosphorous as per Cl. 6.1) Mech- Excluding hydrostatic test and transverse test. For Hardness test, provide sample greater than 10 mm thickness Note: If test bars are sent for mechanical testing, please specify whether hardness and microstructure analysis should be performed on those test bars.
10215 BIS Patna Branch Laboratory (PBL) None IS 8041 (1990) Rapid hardening portland cement - Specific4tion (Second Revision) - - View breakup
Testing charges for the product are: Including Transverse Strength (optional test) test 9,100.00 Excluding Transverse Strength (optional test) test 7,900.00 -Testing charges for only chemical test report: 4,300.00 -Testing charges for only physical test report including optional tests: 4,800.00 -Testing charges for only physical test report excluding optional tests: 3,600.00
- -
All test facilities are available as per the IS
10216 BIS, Eastern Regional Laboratory (ERL) None IS 12330 (1988) Specificatioon for sulphate resisting Portland cement - Rs.12900/- View breakup
-
- -
Facility not available for transverse strength test(Optional)
10217 BIS Patna Branch Laboratory (PBL) None IS 15911 (2010) Structural steel (Ordinary Quality) - Specification - Rs 6750/- For elements other than Table-1: Rs 1004/- pe View breakup
-
- -
All test facilities are available as per the IS except tests for Chromium, Molybdenum, Vanadium, Nickel, Copper, Niobium, Boron, Titanium, Aluminium and Tungsten (Clause 8.2)
10218 BIS, Central Laboratory (CL) None IS 9537 : Part 2 (1981) Specification for conduits for electrical installations: Part 2 rigid steel conduits - Rs 2100/- View breakup
-
- -
excluding Bending Test & Thread Gauge;
10219 BIS Patna Branch Laboratory (PBL) None IS 10124 : Part 2 (2009) Fabricated pvc - U fittings for potable water supplies - Specification: Part 2 specific requirements for sockets (Second Revision) - - View breakup
-
- -
All test facilities are available as per the IS except- i. Short Term Hydrostatic Test (Clause 6.2) ii. Effect on Water (Clause 6.3)
10220 CENTRAL INSTITUTE OF PETROCHEMICALS ENGINEERING AND TECHNOLOGY (CIPET):CSTS-BHOPAL 8100534 IS 4148 (1989) Surgical rubber gloves - Specification (First Revision) - 15400 View breakup
-
31 Dec, 2026 -
Included w.e.f. 27-05-2022.
10221 CENTRAL INSTITUTE OF PETROCHEMICALS ENGINEERING AND TECHNOLOGY (CIPET):CSTS-BHOPAL 8100534 IS 3462 (1986) Unbacked Flexible Pvc Flooring - 19800 View breakup
Rs.17238/- (After 25% discount for BIS)
31 Dec, 2026 -
Included w.e.f. 29.06.2017.
10222 BIS, Central Laboratory (CL) None IS 4581 (1978) Specification for phosphorus trichloride, pure and analytical reagent (First Revision) - - View breakup
-
- -
Excluding Clause 4.2 Table 1 (i) Phosphorus trichloride,;
10223 BIS, Eastern Regional Laboratory (ERL) None IS 1079 (2017) Hot rolled carbon steel sheet, plate and strip - Specification (Seventh Revision) For all grades except tests mentioned in remarks - View breakup
-
- -
Chem: Facility not available for Microalloying elements and Al To declare Grade
10224 Ace Test Labs & Metrology Pvt. Ltd. 9162826 IS 16242 : Part 1 (2014) Uninterruptible power systems (UPS): Part 1 general and safety requirements for UPS - 108000 View breakup
Rs.108000/- (10% discount for BIS)
14 Nov, 2027 -
Only for IP(0-4)(5-6) For UPS/Inverter up to 5KVA), UPS < =10 KVA Excluding: Cl. 4.5/1.5 of RD Components - Cl. 5.6/2.8 of RD Safety Interlocks Cl. 2.10.5.4 & Annex U of RD Semiconductor Devices Cl.2.10.6 PCB material, Cl. 2.10.5.11 Insulation in wound components, CL.7.6 & Annex-M Ventilation of battery Compartment, Annex-L.5 Non linear Loads, Annex-I.5 Solid state backfeed protection Annex-H /Table Protection against Ingress of foreign objects
10225 BIS, Central Laboratory (CL) None IS 4505 (2015) Sodium formaldehyde sulphoxylate - Specification (First Revision) - - View breakup
Testing charges for the product are Rs. 4480/-. Testing Charges for keeping quality: Rs. 4330/-.
- -
-
10226 BIS, Eastern Regional Laboratory (ERL) None IS 1989 : Part 1 (1986) Specification for leather safety boots and shoes: Part 1 for miners (Fourth Revision) For all sizes except test mentioned in remarks Rs 5100/- for safety boots, Rs.4500/- safety shoes View breakup
-
- -
Mech- 2 pairs, Except Colour fastness (Cl 7, Cl 14) Chem-2 pairs
10227 BIS, Central Laboratory (CL) None IS/IEC 60898 : PART 1 (2015) Electrical accessories - Circuit - Breakers for overcurrent protection for household and similar installations: Part 1 circuit - Breakers for a.c. operation (First Revision) - - View breakup
-
- -
Excluding 1. 28 days test , 2.Mechanical and Electrical endurance Test, 3. Short circuit test 4. Tripping test at rated voltage, 5. Mechanical shock test, 6. Impact test, 7. Verification of insulation resistance against Impulse Voltage.
10228 BIS, Eastern Regional Laboratory (ERL) None IS 362 (1991) Parliament Hinges -specification For all types except tests mentioned in remarks - View breakup
Rs.2250/- and material testing charges as per relevant referred Iss
- -
Facility not available for Al,V)
10229 BIS, Southern Regional Laboratory (SRL) None IS 1784 (2020) Screwed Closures for Drums — Specification ( Fourth Revision ) - - View breakup
-
- -
" 6 Nos. Excluding except air pressure test, torque test for steel bungs, curling & thread,chemical tests
10230 BIS, Eastern Regional Laboratory (ERL) None IS 10124 : Part 1 (2009) Fabricated PVC-U Fittings for Potable Water Supplies - Specification Part 1 General Requirements (Second Revision) - Rs 1500/- View breakup
-
- -
Facility not available for Effect on water. short term hydraulic test

Designed, Developed and Maintained by:

Arohatech IT Services (P) Ltd.

Contact for any query/support: supportlims@bis.gov.in