10531 |
BIS, Central Laboratory (CL)
| None
| IS 4123 (1982) |
Specification for chain pipe wrenches (First Revision) |
- |
Rs 2700.00 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
3 Table 1 (Dimensions- Nominal Size) |
- |
|
|
|
3 Table 1 (Dimensions- Capacity, D min) |
- |
|
|
|
3 Table 1 (Dimensions- Capacity, D max) |
- |
|
|
|
3 Table 1 (Dimensions- Length , L) |
- |
|
|
|
3 Table 1 (Dimensions- Length of Jaw, L1) |
- |
|
|
|
3 Table 1 (Dimensions- Width of Jaw, E) |
- |
|
|
|
3 Table 1 (Dimensions- Dia of Handle, d) |
- |
|
|
|
3 Table 1 (Dimensions- Thickness of Jaw, T) |
- |
|
|
|
3 Table 1 (Dimensions- Length of Chain) |
- |
|
|
|
3 Table 1 (Dimensions- Chain Pitch, P) |
- |
|
|
|
6.1 (Construction- Handel) |
- |
|
|
|
6.2 (Construction- Jaws) |
- |
|
|
|
6.3 (Construction- Chain) |
- |
|
|
|
7.1 (Workmanship and Finish ) |
- |
|
|
|
7.2 (Workmanship and Finish ) |
- |
|
|
|
9 (Test) |
- |
|
|
|
|
- |
- Sample size shall be minimum dia> 3mm and thickness > 0.8 mm;
EXCLUDING -; Torque test for above size 80mm |
10532 |
CIPET: CENTRE FOR SKILLING AND TECHNICAL SUPPORT (CSTS) - (CIPET), AURANGABAD
| 7123534
| IS 13488 (2008) |
Irrigation equipment - Emitting pipe systems - Specification (First Revision) |
- |
19062.10 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
5.1(Materials - shall be resistant to fertilizers and
chemicals commonly employed in irrigation, and shall
be suitable for use with water at temperatures up to
60°C and at pressures designed for the emitting pipe) |
- |
1050 |
|
-- |
5.1.2 (Ref. Cl 4.1.a of IS 12786 : 1989)(Potyethylene - higher olefins constituent ) |
- |
1050 |
|
-- |
5.1.2 (Ref. Cl 4.1.b of IS 12786 : 1989)(Potyethylene - anti-oxidant) |
- |
2000 |
|
-- |
5.1.2 (Ref. Cl 4.1.c.i of IS 12786 : 1989)(Density) |
- |
1125 |
|
500+625 |
5.1.2 (Ref. Cl 4.1.c.ii of IS 12786 : 1989)(Toluene extract - Annex A of IS 12786:1989) |
- |
1000 |
|
-- |
5.1.2 (Ref. Cl 4.1.c.iii of IS 12786 : 1989)(Volatile matter - Annex B of IS 12786:1989) |
- |
700 |
|
-- |
5.1.2 (Ref. Cl 4.1.c & 4.2.a of IS 12786 : 1989)(Carbon Black content - IS 2530 : 1963) |
- |
925 |
|
-- |
5.1.2 (Ref. Cl 4.2.b of IS 12786 : 1989)(The dispersion of Carbon Black content shall be satisfactory - IS 2530 : 1963) |
- |
700 |
|
-- |
6.2.2(Fittings) |
- |
250 |
|
-- |
8.1.2(Uniformity of Emission Rate for Unregulated Emitting Pipes) |
- |
1000 |
|
-- |
8.1.3(Uniformity of Emission Rate for Regulated Emitting Pipes) |
- |
1000 |
|
-- |
8.2(Emission Rate of Emitting Unit as a Function of Inlet Pressure) |
- |
1000 |
|
-- |
8.2.1(Unregu/Qt~d Emining Pipe) |
- |
0 |
|
-- |
8.2.2(Regulated Emitting Pipes) |
- |
1000 |
|
-- |
8.3.1(Wall Thickness ofEmitting Pipe) |
- |
250 |
|
-- |
8.3.2(Inside Diameter ofEmitting Pipe) |
- |
250 |
|
-- |
8.3.3(Flow Paths in Emitting Unit) |
- |
200 |
|
-- |
8.3.4(Spacing ofEmitter Units) |
- |
200 |
|
-- |
8.4.1(Resistance to Hydrostatic Pressure at Ambient Temperature) |
- |
1000 |
|
-- |
8.4.2(Resistance to Hydrostatic Pressure at Elevated Temperature) |
- |
1600 |
|
-- |
8.5(Resistance to Tension at Elevated Temperature) |
- |
1100 |
|
-- |
8.6(Resistance to Pull Out of Joints Between Fitting and Emitting
IS 13479) |
- |
400 |
|
-- |
8.7.1(Resistance of PE Emitting Pipe to
Environmental Stress Cracking -Acceptance Test
Annex D of IS 12786) |
- |
1200 |
|
-- |
8.7.2(Resistance of PE Emitting Pipe to
Environmental Stress Cracking - Type Test
Annex D of IS 12786) |
- |
1600 |
|
-- |
8.8(Determination of Emitting Unit Exponent) |
- |
600 |
|
-- |
9.1(DESIGNATION - Non regulated Emitting Pipe) |
- |
0 |
|
-- |
9.2(DESIGNATION - Regulated Emitting Pipe) |
- |
0 |
|
-- |
|
31 Dec, 2026 |
- - |
10533 |
BIS, Central Laboratory (CL)
| None
| IS 1537 (1976) |
Specification for vertically cast iron pressure pipes for water, gas and sewage (First Revision) |
- |
Rs. 3972/- (for flanged ends only) + materials as per View breakup
Rs. 3972/- (for flanged ends only) + materials as per respective ISS.
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
3.1 , 6 of IS 210 ( The composition of cast iron shall be left to the
discretion of the manufacturer) |
- |
|
|
|
4.1 (Tensile Strength) |
- |
|
|
|
4.2 (Hardness test) |
- |
|
|
|
7.1 & Table 2 (DE) |
- |
|
|
|
7.1 & Table 2 (DI) |
- |
|
|
|
7.1 & Table 2 (P) |
- |
|
|
|
7.1 & Table 2 (g) |
- |
|
|
|
7.1 & Table 2 (h) |
- |
|
|
|
7.1 & Table 2 (DC) |
- |
|
|
|
7.1 & Table 2 (c) |
- |
|
|
|
7.1 & Table 2 (f) |
- |
|
|
|
7.1 & Table 3 (DI) |
- |
|
|
|
7.1 & Table 3 (P) |
- |
|
|
|
7.1 & Table 3 (g) |
- |
|
|
|
7.1 & Table 2 (h) |
- |
|
|
|
7.1 & Table 4 (D) |
- |
|
|
|
7.1 & Table 4 (a) |
- |
|
|
|
7.1 & Table 4 (b) |
- |
|
|
|
7.1 & Table 4 (s) |
- |
|
|
|
7.1 & Table 4 (r) |
- |
|
|
|
7.1 & Table 5 (D) |
- |
|
|
|
7.1 & Table 5 (C) |
- |
|
|
|
7.1 & Table 5 (Holes Number) |
- |
|
|
|
7.1 & Table 5 (Holes Diameter) |
- |
|
|
|
7.1 & Table 5 (Diameter of Bolts) |
- |
|
|
|
7.1 & Table 6 to 8 (DE) |
- |
|
|
|
7.1 & Table 6 to 8 (t) |
- |
|
|
|
7.1 & Table 6 to 8 (Mass of one meter barrel (Approx)) |
- |
|
|
|
8.4 (Permissible deviation from a straight line) |
- |
|
|
|
7.1 & Table 6 to 8 (Socket mass (Approx)) |
- |
|
|
|
9.1,Table 9 (Working Length) |
- |
|
|
|
10.1 to 10.6 (Coating ) |
- |
|
|
|
|
- |
- Since the composition of cast iron shall be left to the discretion ofthe manufacturer , as such element to be tested with specified requirement and tolerances if any may please be declared with method of testing. Sample Size 5 pcs of 5x5 cm having dia> 3mm and thickness > 0.8 mm.;
EXCLUDING -; hydraulic test |
10534 |
CIPET: CENTRE FOR SKILLING AND TECHNICAL SUPPORT (CSTS) - (CIPET), AURANGABAD
| 7123534
| IS 13487 (1992) |
Irrigation equipment - Emitters - Specification |
- |
4700 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
7.1(Construction and workmanship) |
- |
300 |
|
Construction & Workmanship |
7.2(Flow path in emitters) |
- |
300 |
|
Flow Path in Emitter |
7.3.1(Resistance to Hydrostatic pressure) |
- |
999.99 |
|
Resistance to Hydrostatic pressure |
7.3.2(Resistance to Hydrostatic pressure) |
- |
0 |
|
included in 7.3.1 |
7.3.3(Resistance to Hydrostatic pressure) |
- |
0 |
|
included in 7.3.1 |
7.4.1(Emitter Pull Out In-line emitters) |
- |
500 |
|
Emitter Pullout |
7.4.2(Emitter Pull Out On-line emitters) |
- |
0 |
|
Included in 7.4.1 |
8.1.2(Uniformity of Emission Rate Unregulated emitters) |
- |
1000 |
|
Uniformity of emission rate |
8.1.3(Uniformity of Emission Rate Regulated emitters) |
- |
0 |
|
Included in 8.1.2 |
8.2.2(Emission rate as a function of inlet pressure Unregulated emitters) |
- |
1000 |
|
Emission rate as a function of inlet pressure |
8.2.3(Emission rate as a function of inlet pressure Regulated emitters) |
- |
0 |
|
Included 8.2.2 |
8.3(Determination of Emitter Exponent) |
- |
600 |
|
Determination of Emitter Exponent |
|
31 Dec, 2026 |
- - |
10535 |
BIS, Central Laboratory (CL)
| None
| IS 11722 (1986) |
Specification for thin walled flexible quick coupling pipes |
- |
4800 View breakup
Rs.4800/- (excluding Hydraulic test) and material testing charges as per relevant referred ISs
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
4.1 (Pipe Manufacturing Process ) |
- |
|
|
|
5,5.1 (Workmsnship &Finish) |
- |
|
|
|
6 &7 ; Table 1 (Dimension & Tolerance) |
- |
|
|
|
8 (Length) |
- |
|
|
|
9 (Galvanizing ,IS 4736) |
- |
|
|
|
10,10.1 (Couplers for thin walled coupling pipes ; Appendix A) |
- |
|
|
|
10,10.2 ,Table 1 (Coupler,Type 1B, IS 5382) |
- |
|
|
|
12 (Straightness) |
- |
|
|
|
13.1 (Flattening Test,IS 2328) |
- |
|
|
|
|
- |
- - |
10536 |
BIS, Central Laboratory (CL)
| None
| IS 9523 (2000) |
Ductile iron fittings for pressure pipes for water, gas and sewage - Specification (First Revision) |
- |
Rs.7245.00 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
Cl 5 (Thickness) |
- |
|
|
|
Cl 6 & Table 4,5,6&7 (Design & Tolerance) |
- |
|
|
|
Cl 9 (Tensile Test & Hardness Test) |
- |
|
|
|
Cl 11 (Nominal Diameter, Ovality, Dimensions, No. Of Holes & Bolt Sizes) |
- |
|
|
|
|
- |
- - |
10537 |
BIS, Central Laboratory (CL)
| None
| IS 903 (1993) |
Specification for Fire Hose Delivery Couplings, Branch Pipe, Nozzles And Nozzle Spanner - Specificaion |
- |
Rs 3600/ View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
Clause 5.2.3 (Zinc Aluminium alloys Casting) (Magnesium ( mg)) |
- |
|
|
|
Clause 5.2.3 (Zinc Aluminium alloys Casting) (Aluminium(Al)) |
- |
|
|
|
Clause 5.2.3 (Zinc Aluminium alloys Casting) (Copper ( Cu)) |
- |
|
|
|
Clause 5.2.2 (Aluminium alloys Casting) (Aluminium(Al)) |
- |
|
|
|
Clause 5.2.2 (Aluminium alloys Casting) (Titanium) |
- |
|
|
|
Clause 5.2.2 (Aluminium alloys Casting) (Lead(Pb)) |
- |
|
|
|
Clause 5.2.2 (Aluminium alloys Casting) (Tin(Sn)) |
- |
|
|
|
Clause 5.2.2 (Aluminium alloys Casting) (Zinc(Zn)) |
- |
|
|
|
Clause 5.2.2 (Aluminium alloys Casting) (Nickel(Ni)) |
- |
|
|
|
Clause 5.2.2 (Aluminium alloys Casting) (Manganese(Mn)) |
- |
|
|
|
Clause 5.2.2 (Aluminium alloys Casting) (Silicon(Si)) |
- |
|
|
|
Clause 5.2.1 (Copper alloys Casting) (Zinc(Zn) IS 318, 291,292,1264) |
- |
|
|
|
Clause 5.2.1 (Copper alloys Casting) (Tin(Sn)) |
- |
|
|
|
Clause 5.2.1 (Copper alloys Casting) (Lead(Pb)) |
- |
|
|
|
Clause 5.2.1 (Copper alloys Casting) (Nickel(Ni)) |
- |
|
|
|
Clause 5.2.1 (Copper alloys Casting) (Aluminium(Al)) |
- |
|
|
|
Clause 5.2.1 (Copper alloys Casting) (Silicon(Si)) |
- |
|
|
|
Clause 5.2.1 (Copper alloys Casting) (Antimony(Sb)) |
- |
|
|
|
Clause 5.2.1 (Copper alloys Casting) (Iron(Fe)) |
- |
|
|
|
Clause 5.2.1 (Copper alloys Casting) (Other impurities) |
- |
|
|
|
Clause 5.2.1 (Copper alloys Casting) (Copper ( Cu)) |
- |
|
|
|
Clause 5.2.2 (Aluminium alloys Casting) (Copper ( Cu) IS 617) |
- |
|
|
|
3 (Finish and workmanship) |
- |
|
|
|
5 (Delivery hose coupling) |
- |
|
|
|
5.3 (Size and Dimension ) |
- |
|
|
|
5.3 (Size and Dimension ) |
- |
|
|
|
5.4 (Hydraulic test requirement) |
- |
|
|
|
6 (Branch pipe) |
- |
|
|
|
6.3 (Hydraulic test requirement) |
- |
|
|
|
7 (Nozzle) |
- |
|
|
|
7 (Nozzle) |
- |
|
|
|
7.3 (Hydraulic test requirement) |
- |
|
|
|
|
- |
- Sample size shall be minimum dia> 3mm and thickness > 0.8 mm;
EXCLUDING all except IS 318 : 1974, Complete for material; Thread of Sample is not carried due to non availability of Ring Gauge as per G 1¾ of IS :2643(Part 1), Fillet radius >25 mm |
10538 |
BIS, Central Laboratory (CL)
| None
| IS 704 (1984) |
Specification for crow - Bars and claw - Bars (Second Revision) |
- |
Total Rs.11x 300 = Rs.3300.00 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
2 (Type) |
- |
|
|
|
3 Table-1 to 9 (Shapes And Dimensions-Width across flats ) |
- |
|
|
|
3 Table-1 to 9 (Shapes And Dimensions-Diameter of bars) |
- |
|
|
|
7 (Manufacture and Finish) |
- |
|
|
|
8.1 (Drop Test) |
- |
|
|
|
|
- |
- - |
10539 |
CIPET: CENTRE FOR SKILLING AND TECHNICAL SUPPORT (CSTS) - (CIPET), AURANGABAD
| 7123534
| IS 12701 (1996) |
Rotational moulded polyethylene water storage tanks - specification (First Revision) |
- |
11625 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
4.2.3(Carbon Black Content ) |
- |
925 |
|
Carbon black content * |
4.2.3(Carbon Dispersion Test) |
- |
700 |
|
Carbon black content |
5(Types and Features ) |
- |
3100 |
|
Net & Gross Capacity 500
Overall Diameter 250
Overall Height 250
Internal dia of man - hole 250
Wall thickness upon effective height 250
Wall thickness above effective height 250
Minimum weight without lid 500 |
5.1 Table 1(Dimensioas of Cylinderical Vertical Tank) |
- |
0 |
|
included in Types and feature |
5.1 Table 1(Dimensioas of Cylinderical Vertical Tank) |
- |
0 |
|
included in Types and feature |
5.1 Table 1(Dimensioas of Cylinderical Vertical Tank) |
- |
0 |
|
included in Types and feature |
5.1 Table 1(Dimensioas of Cylinderical Vertical Tank) |
- |
0 |
|
included in Types and feature |
5.1 Table 1(Dimensioas of Cylinderical Vertical Tank) |
- |
0 |
|
included in Types and feature |
5.1 Table 1(Dimensioas of Cylinderical Vertical Tank) |
- |
0 |
|
included in Types and feature |
5.1 Table 1(Dimensioas of Cylinderical Vertical Tank) |
- |
0 |
|
included in Types and feature |
5.2 Table 2(Dimensions of Rectangular Loft Tanks) |
- |
0 |
|
included in Types and feature |
5.2 Table 2(Dimensions of Rectangular Loft Tanks) |
- |
0 |
|
included in Types and feature |
5.2 Table 2(Dimensions of Rectangular Loft Tanks) |
- |
0 |
|
included in Types and feature |
5.2 Table 2(Dimensions of Rectangular Loft Tanks) |
- |
0 |
|
included in Types and feature |
5.2 Table 2(Dimensions of Rectangular Loft Tanks) |
- |
0 |
|
included in Types and feature |
5.2 Table 2(Dimensions of Rectangular Loft Tanks) |
- |
0 |
|
included in Types and feature |
5.3(Types and Features ) |
- |
0 |
|
included in Types and feature |
5.6(Types and Features ) |
- |
0 |
|
included in Types and feature |
6.1(Finish) |
- |
300 |
|
Finish / Visual Appearance |
7.1.1(Resistance to Deformation) |
- |
700 |
|
Resistance to deformation |
7.1.2(Resistance to Deformation) |
- |
0 |
|
Resistance to deformation |
7.2(Resistance to Impact) |
- |
1100 |
|
Resistance to impact |
7.3(Test for Top Load Resistance) |
- |
900 |
|
Top load resistance (for 1500 lit and more) |
7.4(Tensile Strength) |
- |
1100 |
|
Tensile Strength |
7.5(Flexural Modulus) |
- |
1100 |
|
Flexural modulus |
7.6(overall Migration) |
- |
1700 |
|
Overall Migration 40°C / Water/ 10 days |
|
31 Dec, 2026 |
- - |
10540 |
Research & Development Centre for Bicycle and Sewing Machine, Ludhiana
| 9100634
| IS 2414 (2005) |
Cycle and rickshaw pneumatic tyres - Specification (Fourth Revision) |
- |
14700 View breakup
Rs.14700/- + GST
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
5.1 & 5.2(Dimensions) |
- |
0 |
|
+ GST@18% |
6.2(Tyre Cord) |
- |
0 |
|
-- |
6.3(Tyre Casing Strength) |
- |
0 |
|
-- |
6.4(Bead Wire Joint) |
- |
0 |
|
-- |
6.5(Requirements of Ruber Compound) |
- |
0 |
|
-- |
6.6(Adhesion test) |
- |
0 |
|
-- |
6.7(Performance test) |
- |
0 |
|
-- |
|
31 Dec, 2026 |
- 0.0 |
10541 |
BIS, Central Laboratory (CL)
| None
| IS 884 (1985) |
Apecification for first - Aid hose - Reel for fire fighting (First Revision) |
- |
2700/- View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
Cl 5.1 (Dimensions) |
- |
|
|
|
Cl 5.1 (Dimensions) |
- |
|
|
|
Cl 5.1 (Dimensions) |
- |
|
|
|
Cl 5.2 (Resistance to Leakage) |
- |
|
|
|
Cl 5.5 (Swinging) |
- |
|
|
|
Cl 5.6 (Reel Action) |
- |
|
|
|
Cl 6 (Workmanship) |
- |
|
|
|
Cl 7 (Painting) |
- |
|
|
|
|
- |
- EXCLUDING Impact resistance,Load resistance,Range & flow rate |
10542 |
CIPET: CENTRE FOR SKILLING AND TECHNICAL SUPPORT (CSTS) - (CIPET), AURANGABAD
| 7123534
| IS 7834 : Part 3 (1987) |
injection moulded PVC socket fittings with solvent cement joints for water supplies: Part 3 Specific requirements for 90 degree elbows |
- |
7514 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
cl 2.2.2(Dimensions) |
- |
500 |
|
Dimension |
Cl. 2.1 (Ref. Cl. 6.3 of IS 7834 (part 1) : 1987(Effect on water - Lead (first extraction) - Appendix C ) |
- |
3000 |
|
Effect on water test |
Cl. 2.1 (Ref. Cl. 6.3 of IS 7834 (part 1) : 1987(Effect on water - Lead (third extraction) - Appendix C) |
- |
0 |
|
Effect on water test |
Cl. 2.1 (Ref. Cl. 6.3 of IS 7834 (part 1) : 1987(Effect on water - Other toxic substances (third extraction) - Appendix C) |
- |
0 |
|
Effect on water test |
|
31 Dec, 2026 |
- - |
10543 |
Matrix Test Labs
| 8138626
| IS 302 : Part 2 : Sec 25 (2014) |
Safety of household and similar electrical appliances: Part 2 Particular requirements: Section 25 Microwave ovens |
- |
150000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
7(Marking and instructions) |
- |
5000 |
|
10% discount to BIS |
8(Protection against live parts) |
- |
5000 |
|
10% discount to BIS |
10(POWER INPUT AND CURRENT) |
- |
10000 |
|
10% discount to BIS |
11(HEATING) |
- |
10000 |
|
10% discount to BIS |
13(LEAKAGE CURRENT AND ELECTRIC STRENGTH AT OPERATING TEMPERATURE) |
- |
5000 |
|
10% discount to BIS |
15(HUMIDITY TREATMENT TEST) |
- |
5000 |
|
10% discount to BIS |
16(LEAKAGE CURRENT AND ELECTRIC STRENGTH) |
- |
5000 |
|
10% discount to BIS |
17(OVERLOAD PROTECTION OF TRANSFORMERS AND ASSOCIATED CIRCUITS) |
- |
5000 |
|
10% discount to BIS |
18(ENDURANCE) |
- |
35000 |
|
10% discount to BIS |
19(ABNORMAL OPERATION) |
- |
10000 |
|
10% discount to BIS |
20(STABILITY AND MECHANICAL HAZARDS) |
- |
5000 |
|
10% discount to BIS |
21(MECHANICAL STRENGTH) |
- |
5000 |
|
10% discount to BIS |
22(CONSTRUCTION) |
- |
5000 |
|
10% discount to BIS |
23(INTERNAL WIRING) |
- |
5000 |
|
10% discount to BIS |
25(SUPPLY CONNECTION AND EXTERNAL FLEXIBLE CORDS) |
- |
5000 |
|
10% discount to BIS |
26(TERMINALS FOR EXTERNAL CONDUCTORS) |
- |
5000 |
|
10% discount to BIS |
27(PROVISION FOR EARTHING) |
- |
5000 |
|
10% discount to BIS |
28(SCREWS AND CONNECTIONS) |
- |
5000 |
|
10% discount to BIS |
29(CLEARANCES, CREEPAGE DISTANCES AND SOLID INSULATION) |
- |
5000 |
|
10% discount to BIS |
30(RESISTANCE TO HEAT AND FIRE) |
- |
5000 |
|
10% discount to BIS |
31(RESISTANCE TO RUSTING) |
- |
10000 |
|
10% discount to BIS |
32(RADIATION, TOXICITY AND SIMILAR HAZARDS) |
- |
10000 |
|
10% discount to BIS |
6.0(Classification) |
- |
0 |
|
- |
24(COMPONENTS) |
- |
15000 |
|
10% discount to BIS |
14(IMPULSE VOLTAGE TEST) |
- |
25000 |
|
10% discount to BIS |
|
31 Dec, 2026 |
- Excluding: EMI/EMC (Cl.19.11.4.1 to 19.11.4.7), Cord Reel Test Set-up (Cl.22.16), Software (Cl.22.46), Water Pressure Inlet (Cl.22.47), Interlocks (Cl.22.106), Component (Cl.24), Appliance for board ships (Annex-BB) & Salt spray test (Annex-CC). |
10544 |
Matrix Test Labs
| 8138626
| IS 15885 : Part 2 : Sec 13 (2012) |
Safety of lamp controlgear: Part 2 particular requirements: Sec 13 d.c. or a.c. supplied electronic controlgear for led modules |
- |
75000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
7(Marking) |
- |
5000 |
|
10% discount to BIS |
8(Protection against accidental contact with live parts) |
- |
5000 |
|
10% discount to BIS |
9(Terminals) |
- |
5000 |
|
10% discount to BIS |
10(PROVISION FOR EARTHING) |
- |
5000 |
|
10% discount to BIS |
11(MOISTURE RESISTANCE) |
- |
5000 |
|
10% discount to BIS |
12(Electric Strength) |
- |
5000 |
|
10% discount to BIS |
14(Fault conditions) |
- |
10000 |
|
10% discount to BIS |
15(Transformer heating) |
- |
15000 |
|
10% discount to BIS |
16(Construction) |
- |
5000 |
|
10% discount to BIS |
17(Creepage distance and clearances) |
- |
5000 |
|
10% discount to BIS |
18(Screws, current carrying parts and connections) |
- |
5000 |
|
10% discount to BIS |
19(Resistance to heat, fire and tracking) |
- |
10000 |
|
10% discount to BIS |
20(Resistance to corrosion) |
- |
10000 |
|
10% discount to BIS |
|
31 Dec, 2026 |
- Excluding: Components: Enclosure, Bridging resistor in primary circuit, Capacitor and RC units, RF suppression (X-Y capacitors), Inductor, MOV/VDR, SMPS/Mains Transformer, PCB material, Metal base PCB for LED, Transparent cover, Bobbin, Insulated tape, Heat shrinkage sleeve, Connector, Fuse, Internal wire, LED, Opto-coupler, EMI/EMC filter, Winding wire, Thin sheet materials etc. |
10545 |
Matrix Test Labs
| 8138626
| IS 16102 : Part 1 (2012) |
Self - Ballasted led lamps for general lighting services: Part 1 safety requirements |
- |
80000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
5(Marking) |
- |
5000 |
|
10% Discount to BIS |
6(Interchangeability) |
- |
10000 |
|
10% Discount to BIS |
7(Protection against accidental contact with live parts) |
- |
5000 |
|
10% Discount to BIS |
8(Insulation Resistance and Electric Strength) |
- |
15000 |
|
10% Discount to BIS |
9(MECHANICAL STRENGTH) |
- |
10000 |
|
10% Discount to BIS |
10(cap temperature) |
- |
10000 |
|
10% Discount to BIS |
11(Resistance to Heat) |
- |
10000 |
|
10% Discount to BIS |
12(Resistance to Flame and Ignition) |
- |
10000 |
|
10% Discount to BIS |
13(Fault conditions) |
- |
10000 |
|
10% Discount to BIS |
14(Creepage distance and clearances) |
- |
5000 |
|
10% Discount to BIS |
|
31 Dec, 2026 |
- Restricted to Cap type B22d, E14 & E27 only. |
10546 |
Building Fire Research Centre, Mysore
| 6124933
| IS 15683 (2018) |
Portable Fire Extinguishers — Performance and Construction — Specification ( First Revision ) |
- |
- View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
No Record Found
|
|
15 Jul, 2021 |
- - |
10547 |
BIS, Central Laboratory (CL)
| None
| IS 15450 (2004) |
Polyethylene/aluminium/polyethylene composite pressure pipes for hot and cold water supplies - Specification |
- |
5250 View breakup
Rs. 5250/- excluding material, pressure rating, density, hydraulic characteristics, type test (Cl. 11.1), carbon black content & dispersion and pigment dispersion.
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
8, Table-2 (Dimension) |
- |
|
|
|
|
- |
- - |
10548 |
BIS, Central Laboratory (CL)
| None
| IS 12823 (2015) |
Prelaminated Particle Boards from Wood and other Lignocellulosic Material - Specification ( First Revision ) |
- |
- View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
Cl 10.13 & Annex F ( Test For Resistance to Cigarette Burn) |
- |
|
|
|
Cl 10.12 & Annex E ( Test For Crack Resistance) |
- |
|
|
|
Cl 10.9 (Test For Screw Withdrawal Strength) |
- |
|
|
|
Cl 10.8 (For Determination of Tensile Strength Perpendicular to Surface After Ageing Test) |
- |
|
|
|
Cl 10.7 (For Determination of Tensile Strength Perpendicular to Surface) |
- |
|
|
|
Cl 10.6 (Tesr For Modulus Of Elasticity & Mudulus Of Rupture) |
- |
|
|
|
Cl 10.5 (For Swelling in water Test ) |
- |
|
|
|
Cl 10.4 (For Water AbsorptionTest ) |
- |
|
|
|
Cl 10.3 (Test For Moisture Content) |
- |
|
|
|
Cl 10.2 (Test For Density) |
- |
|
|
|
Cl 8 (Dimensions & Tolerances) |
- |
|
|
|
Cl 7 (Finish) |
- |
|
|
|
Cl 6 (Manufacture) |
- |
|
|
|
Cl 10.15 (Test for Formaldehyde Content/Emission) |
- |
|
|
|
|
- |
- Sample Test Parameter not available in CL:
"10.4 Test for Water Absorption, 10.5 Test for Swelling in Water, 10.6 Test for Modulus of Rupture (MOR)
and Modulus of Elasticity (MOE), 10.8 Test for Tensile Strength Perpendicular
to Surface After Ageing, 10.10 Test for Abrasion Resistance, 10.11 Test for Resistance to Steam, 10.14 Test for Resistance to Stain."
SIZE: One Board For All Tests
Sample Size without dimensional measurements:Length-1200 mm, width-1200 |
10549 |
Research & Development Centre for Bicycle and Sewing Machine, Ludhiana
| 9100634
| IS 2403 (2014) |
Short - Pitch transmission precision roller and bush chains, attachments and associated chain sprockets (Third Revision) |
- |
4500 View breakup
Rs.4,500/- + GST
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
3.3 Table-1,2(Dimensions- Pitch- p) |
- |
0 |
|
+ GST@18% |
3.3 Table-1,2(Dimensions- Roller diameter- d1) |
- |
0 |
|
-- |
3.3 Table-1,2(Dimensions- Width between
inner plates- b1) |
- |
0 |
|
-- |
3.3 Table-1,2(Dimensions- Bearing pin body diameter- d2) |
- |
0 |
|
-- |
3.3 Table-1,2(Dimensions-Bush bore-d3) |
- |
0 |
|
-- |
3.3 Table-1,2(Dimensions- Chain path depth- h1) |
- |
0 |
|
-- |
3.3 Table-1,2(Dimensions-Inner plate depth- h2) |
- |
0 |
|
-- |
3.3 Table-1,2(Dimensions-Outer plate depth- h3) |
- |
0 |
|
-- |
3.3 Table-1,2(Dimensions- Cranked link dimensions- l2) |
- |
0 |
|
-- |
3.3 Table-1,2(Dimensions- Cranked link dimensions- c) |
- |
0 |
|
-- |
3.3 Table-1,2(Dimensions- Transverse pitch- pt) |
- |
0 |
|
-- |
3.3 Table-1,2(Dimensions- Width over inner link- b2) |
- |
0 |
|
-- |
3.3 Table-1,2(Dimensions- Width between outer plates- b3) |
- |
0 |
|
-- |
3.3 Table-1,2(Dimensions- Width over bearing pins- b4) |
- |
0 |
|
-- |
3.3 Table-1,2(Dimensions- Width over bearing pins- b5) |
- |
0 |
|
-- |
3.3 Table-1,2(Dimensions- Width over bearing pins- b6) |
- |
0 |
|
-- |
3.3 Table-1,2(Dimensions- Additional width for joint fastener- b7) |
- |
0 |
|
-- |
3.4.2(Tensile Test) |
- |
0 |
|
-- |
3.4.3(Preloading) |
- |
0 |
|
-- |
3.4.4(Length validation- Measuring load) |
- |
0 |
|
-- |
3.4.4(Length validation- Length) |
- |
0 |
|
-- |
3.4.5(Dynamic testing) |
- |
0 |
|
-- |
|
31 Dec, 2026 |
- EXCLUDING - Dynamic Strength test |
10550 |
BIS, Central Laboratory (CL)
| None
| IS 8808 (2019) |
Burners for oil pressure stoves and oil pressure heaters - Specification (Third Revision) |
- |
Rs. 6600/ View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
4 (TYPES) |
- |
|
|
|
6.1 (SHAPE, SIZES AND DIMENSIONS - FIG. 1A,1B AND 2) |
- |
|
|
|
6.1 (SHAPE, SIZES AND DIMENSIONS - FIG. 3A,3B AND 3C) |
- |
|
|
|
8 (FINISH) |
- |
|
|
|
10.1 (TESTS-Pressure Tests) |
- |
|
|
|
10.2 (TESTS-Tests for Thermal Efficiency) |
- |
|
|
|
5 (MATERIALS- Roarer type
burner) |
- |
|
|
|
5 (MATERIALS-Silencer type
burner) |
- |
|
|
|
5 (MATERIALS- Tube type
burner) |
- |
|
|
|
|
- |
- EXCLUDING "-; 10.2 -Thermal Efficiency,10.1 -Pressure Tests," |
10551 |
Research & Development Centre for Bicycle and Sewing Machine, Ludhiana
| 9100634
| IS 2415 (2015) |
Cycle - Rubber tubes (Moulded/ Jointed) - Specification (Fourth Revision) |
- |
8700 View breakup
Rs.8700/- + GST
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
5.1,3.4, Annex A & Table 2.( Flat Length ) |
- |
0 |
|
+GST@18% |
5.2, Annex A(Thickness) |
- |
0 |
|
-- |
5.1,3.5, Annex A & Table 2.(Flat Width) |
- |
0 |
|
-- |
5.2.1(Uniformity of Thickness) |
- |
0 |
|
-- |
6.1,Table 3(i)Tensile strength:) |
- |
0 |
|
-- |
6.1,Table 3(ii)Elongation at break ) |
- |
0 |
|
-- |
6.2(iii)Tension set: ) |
- |
0 |
|
-- |
6.3 (a)( Ageing Test:- Tensile strength :) |
- |
0 |
|
-- |
6.3(b)( Ageing Test :- Elongation at break) |
- |
0 |
|
-- |
6.4.3( Strength of splice on moulded tube) |
- |
0 |
|
-- |
6.7.3(Manufacture and Workmanship) |
- |
0 |
|
-- |
|
31 Dec, 2026 |
- 0.0 |
10552 |
BIS, Central Laboratory (CL)
| None
| IS 9762 (1994) |
Specification for polyethylene floats (Spherical) for float valves |
- |
Rs.4500/ View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
cl 8.1 (Leakage & water ab. Test) |
- |
|
|
|
cl 8.2 (Deflection Test) |
- |
|
|
|
cl 8.3 (Impact test) |
- |
|
|
|
cl 8.4 (Boss test) |
- |
|
|
|
|
- |
- - |
10553 |
Research & Development Centre for Bicycle and Sewing Machine, Ludhiana
| 9100634
| IS 6218 (2008) |
Bicycle - Mudguards - Specification (First Revision) |
- |
7200 View breakup
Rs.7200/- + GST
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
Clause-3(Carbon) |
- |
0 |
|
-- |
Clause-3(Sulphur) |
- |
0 |
|
-- |
Clause-3(Phosphorus) |
- |
0 |
|
-- |
Clause-3(Manganse) |
- |
0 |
|
-- |
Clause-3(Silicon) |
- |
0 |
|
-- |
Clause-3(Aluminium) |
- |
0 |
|
-- |
Clause-3(Chromium) |
- |
0 |
|
-- |
Clause-3(Nickel) |
- |
0 |
|
-- |
Clause-3(Niobium) |
- |
0 |
|
-- |
Clause-3(Vanadium) |
- |
0 |
|
-- |
Clause-3(Titanium) |
- |
0 |
|
-- |
Clause-3(Molybdenum) |
- |
0 |
|
-- |
Clause-3(Boron) |
- |
0 |
|
-- |
|
31 Dec, 2026 |
- . |
10554 |
BIS, Central Laboratory (CL)
| None
| IS 3989 (2009) |
Centrifugally cast (Spun) iron spigot and socket soil, waste, ventilating and rainwater pipes, fittings and accessories - Specification (Third Revision) |
- |
Rs. 3600/- and Material testing charges as per relevant View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
5 (Hydrostatic Test) |
- |
|
|
|
6.2,6.3, Table 1 & 4 (Dimensions & Tolerances, mm) |
- |
|
|
|
6.2,6.3, Table 1 & 4 (Equal branches without access door,mm) |
- |
|
|
|
6.2,6.3, Table 1 & 4 (Barrel) |
- |
|
|
|
6.2,6.3, Table 1 & 4 (Socket) |
- |
|
|
|
6.2,6.3, Table 1 & 4 (Joint Thickmess) |
- |
|
|
|
8 (Coating Test) |
- |
|
|
|
|
- |
- Since the composition of cast iron shall be left to the discretion ofthe manufacturer , as such element to be tested with specified requirement and tolerances if any may please be declared with method of testing. Sample Size 5 pcs of 5x5 cm having dia> 3mm and thickness > 0.8 mm.;
EXCLUDING -; hydraulic test |
10555 |
Research & Development Centre for Bicycle and Sewing Machine, Ludhiana
| 9100634
| IS 623 (2008) |
Bicycle - Bicycle frames - Specification (Third Revision) |
- |
19000 View breakup
Rs.19000/- + GST
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
4.1(FRAME TUBES ) |
- |
0 |
|
+ GST@18% |
4.1(CHAIN SIDE) |
- |
0 |
|
-- |
4.1(BACK STAY) |
- |
0 |
|
-- |
4.2(SCREW THREADS) |
- |
0 |
|
-- |
7.1(a) TRUENESS OF FRAME) |
- |
0 |
|
-- |
7.2.1(b) IMPACT TEST (Falling Mass)) |
- |
0 |
|
-- |
7.2.2(c) IMPACT TEST (Falling Frame & Fork Assembly)) |
- |
0 |
|
-- |
7.3(d) TEST FOR FINISH) |
- |
0 |
|
-- |
|
31 Dec, 2026 |
- 0.0 |
10556 |
Matrix Test Labs
| 8138626
| IS 16242 : Part 1 (2014) |
Uninterruptible power systems (UPS): Part 1 general and safety requirements for UPS |
- |
125000 View breakup
Rs.1,25,000/- UPS/ Invertors Up to 5
kVA)
[10% discount to BIS]
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
4.6(Power interface) |
- |
15000 |
|
10% discount to BIS |
4.7(Marking & instructions) |
- |
10000 |
|
10% discount to BIS |
5.1(Protection against shock and energy hazards) |
- |
5000 |
|
10% discount to BIS |
5.2(Requirement of auxiliary circuits) |
- |
5000 |
|
10% discount to BIS |
5.3(Protective earthing and bonding) |
- |
5000 |
|
10% discount to BIS |
5.5(Over current and earth fault condition) |
- |
5000 |
|
10% discount to BIS |
5.6(Safety interlocks) |
- |
5000 |
|
10% discount to BIS |
5.7(CLEARANCES, CREEPAGE DISTANCES AND SOLID INSULATION) |
- |
5000 |
|
10% discount to BIS |
6.1(Wiring, connections and supply) |
- |
5000 |
|
10% discount to BIS |
6.2(Connection to power) |
- |
5000 |
|
10% discount to BIS |
6.3(Wiring terminals for external power conductors) |
- |
5000 |
|
10% discount to BIS |
7.2(STABILITY) |
- |
5000 |
|
10% discount to BIS |
7.3(MECHANICAL STRENGTH) |
- |
5000 |
|
10% discount to BIS |
7.4(Construction details) |
- |
5000 |
|
10% discount to BIS |
7.5(Resistance to fire) |
- |
10000 |
|
10% discount to BIS |
7.6(Battery location) |
- |
5000 |
|
10% discount to BIS |
7.7(Temperature rise) |
- |
15000 |
|
10% discount to BIS |
8.1(General procision for earth leakage) |
- |
5000 |
|
10% discount to BIS |
8.2(Electric Strength) |
- |
5000 |
|
10% discount to BIS |
8.3(Abnormal operating and fault conditions) |
- |
10000 |
|
10% discount to BIS |
9.0(Connection to telecommunication networks) |
- |
10000 |
|
10% discount to BIS |
4.5(Components) |
- |
15000 |
|
10% discount to BIS |
5.4(AC and DC power isolation) |
- |
0 |
|
- |
7.1(Enclosure) |
- |
5000 |
|
10% discount to BIS |
|
31 Dec, 2026 |
- Following Additional
Test Facility included
w.e.f. 18.09.2018:
Protection against
ingress of foreign
objects (IPX7 & IPX8
only) (Cl.1.2 & AnnexH).
Excluding: Non-linear
loads (Cl.3.3),
Components (Cl.4.5 /
RD 1.5), Protection of
Personnel-Safety
Interlocks (Cl. 5.6/ RD
Cl.2.8.5, Cl.2.8.7.1 to
Cl.2.8.7.3),
Semiconductor devices
(Cl.2.10.5.4 of RD) and
Insulation in wound
components
(Cl.2.10.5.11 of RD). |
10557 |
Matrix Test Labs
| 8138626
| IS 10322 : Part 5 : Sec 1 (2012) |
Luminaires: Part 5 particular requirements: Sec 1 fixed general purpose luminaires (First Revision) |
- |
80000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
6.0(Marking) |
- |
5000 |
|
10% discount to BIS |
7.0(Construction) |
- |
10000 |
|
10% discount to BIS |
8.0(Creepage Distance and Clearances) |
- |
5000 |
|
10% discount to BIS |
9.0(Provision for earthing) |
- |
5000 |
|
10% discount to BIS |
10.0(Terminals) |
- |
10000 |
|
10% discount to BIS |
11.0(External & Internal Wiring) |
- |
5000 |
|
10% discount to BIS |
12.0(Protection against electric shock) |
- |
10000 |
|
10% discount to BIS |
13.0(Endurance Tests and Thermal Tests) |
- |
20000 |
|
10% discount to BIS |
14.0(Resistance to Dust & Moisture) |
- |
15000 |
|
10% discount to BIS |
15.0(Insulation Resistance and Electric Strength) |
- |
10000 |
|
10% discount to BIS |
16.0(Resistance to Heat , fire and tracking) |
- |
10000 |
|
10% discount to BIS |
4(General Test Requireements) |
- |
0 |
|
- |
5(Classification of Luminaires') |
- |
0 |
|
- |
|
31 Dec, 2026 |
- Following Additional
Test Facility included
w.e.f. 18.09.2018:
Resistance to dust, solid
objects & moisture for
IPX7 & IPX8 (Cl.9.2.8 &
Cl.9.2.9) as per (RD) IS
10322(Part-1):2014.
Excluding:
Electromechanical
Contact System
(Cl.4.11.6), UV
Radiation (Cl.4.24,
Annex-P), Short
circuit protection (Cl.
4.26.2) as per (RD) IS
10322(Part-1):2014 and
Photometric test (Cl.17). |
10558 |
Matrix Test Labs
| 8138626
| IS 16046 : Part 2 (2018) |
Secondary Cells and Batteries Containing Alkaline or Other Non-Acid Electrolytes ” Safety Requirements for Portable Sealed Secondary Cells and for Batteries Made from Them for Use in Portable Applications Part 2 Lithium Systems ( Second Revision ) |
- |
180000 View breakup
Rs.1,80,000/- [10% discount to BIS]
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
5(General Safety Considerations) |
- |
5000 |
|
10% discount to BIS |
6(Type Test and Sample Size) |
- |
5000 |
|
10% discount to BIS |
7.1(Charging procedure for test purposes) |
- |
20000 |
|
10% discount to BIS |
7(Specific requirements and tests) |
- |
5000 |
|
10% discount to BIS |
7.2(Intended Use) |
- |
35000 |
|
10% discount to BIS |
7.3(Reasonably foreseeable misuse) |
- |
110000 |
|
10% discount to BIS |
10(Packaging) |
- |
0 |
|
- |
8.2(Small Cell and battery safety information) |
- |
5000 |
|
10% discount to BIS |
5.8(Battery Safety Components) |
- |
15000 |
|
10% discount to BIS |
9(Marking) |
- |
3000 |
|
10% discount to BIS |
9.1(Cell Marking) |
- |
3000 |
|
10% discount to BIS |
5.2(Insulation and Wiring) |
- |
5000 |
|
10% discount to BIS |
5.3(Venting) |
- |
0 |
|
- |
5.4(Temperature, Voltage and Current Management) |
- |
0 |
|
- |
5.5(Terminal Contacts) |
- |
0 |
|
- |
5.6(Assembly of Cells into batteries) |
- |
0 |
|
- |
5.7(Quality Plan) |
- |
0 |
|
- |
4(Parameter Measurement Tolerances) |
- |
0 |
|
- |
5.1(General) |
- |
0 |
|
- |
8(Information for safety) |
- |
0 |
|
- |
9.2(Battery Marking) |
- |
0 |
|
- |
9.3(Caution for ingestion of small cells and batteries) |
- |
0 |
|
- |
9.4(Other information) |
- |
0 |
|
- |
|
31 Dec, 2026 |
- REVISED VERSION
Included w.e.f.
14.01.2019. |
10559 |
CENTRAL INSTITUTE OF PETROCHEMICALS ENGINEERING AND TECHNOLOGY (CIPET):CSTS-BHOPAL
| 8100534
| IS 14333 (1996) |
High Density Polyethylene Pipe For Sewerage - |
- |
11475 View breakup
Rs.8681/-,
Rs.3044/- Raw material
(After 25% discount for BIS)
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
10(Marking) |
- |
0 |
|
Nil |
3(Designation) |
- |
0 |
|
Nil |
4(Colour) |
- |
300 |
|
Nil |
6(Dimensions of pipes) |
- |
250 |
|
Nil |
7(Visual Appearance) |
- |
300 |
|
Nil |
8.1(Hydraulic characteristics) |
- |
6400 |
|
Type test for 168 hrs = Rs. 4800/- and Acceptance test for 48 hrs = Rs. 1600/- |
8.2(Reversion) |
- |
1000 |
|
Test charges Rs. 700 plus specimen charges Rs.300/- (25 % discount is not applicable in specimen charges) |
8.3(Density) |
- |
500 |
|
Nil |
8.4(Melt Flow Rate) |
- |
1100 |
|
Nil |
Cl. 8.5, IS 2530-1963, Cl. 10(Cabon Black Content) |
- |
925 |
|
Nil |
Cl. 8.5, IS 2530-1963, Cl. 16(Carbon Black Dispersion) |
- |
700 |
|
Nil |
|
31 Dec, 2026 |
- Upto 600 mm DN and excluding Chemical resistance classification (Annexure-D) |
10560 |
CENTRAL INSTITUTE OF PETROCHEMICALS ENGINEERING AND TECHNOLOGY (CIPET):CSTS-BHOPAL
| 8100534
| IS 14252 (2015) |
Textiles – High density polyethylene (HDPE)/ polypropylene (PP) woven sack for filling sand – Specification (second revision) |
- |
19140 View breakup
Rs.16903/-
(After 25% discount for BIS)
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
3.1(Raw Material) |
- |
1050 |
|
Nil |
3.2(Tapes – Width
) |
- |
250 |
|
Nil |
3.2(Tapes – Linear Density
) |
- |
250 |
|
Nil |
3.3(Tying Cord) |
- |
0 |
|
Charges already taken |
3.3(Tying Cord) |
- |
0 |
|
Charges already taken |
3.3(Tying Cord) |
- |
0 |
|
Charges already taken |
3.4(Sack) |
- |
0 |
|
Charges already taken |
3.4.1(Seam) |
- |
0 |
|
Charges already taken |
3.4.1(Seam) |
- |
0 |
|
Charges already taken |
3.4.1(Seam) |
- |
0 |
|
Charges already taken |
3.4.1(Seam) |
- |
0 |
|
Charges already taken |
4.1 and Table 1 i a(Dimensions Outside Length) |
- |
250 |
|
Nil |
4.1 and Table 1 i b(Dimensions Outside Width) |
- |
0 |
|
Charges already taken in clause no. 4.1 and Table 1 i a |
4.1 and Table 1 ii(Ends per dm ) |
- |
250 |
|
Nil |
4.1 and Table 1 iii(Picks per dm ) |
- |
250 |
|
Nil |
4.2 and Table 1 iv(Mass of sack
) |
- |
300 |
|
Nil |
4.1 and Table 1 v a(Average breaking strength of fabric Warpway
) |
- |
1100 |
|
Nil |
4.1 and Table 1 v b(Average breaking strength of fabric Weftway
) |
- |
1100 |
|
Nil |
4.1 and Table 1 vi(Average Breaking strength of bottom seam ) |
- |
1100 |
|
Nil |
4.1 and Table 1 vii a(Elongation at break of fabric Lengthwise) |
- |
1100 |
|
Nil |
4.1 and Table 1 vii b(Elongation at break of fabric Widthwise ) |
- |
1100 |
|
Nil |
4.1 and Table 1 viii(Average breaking strength and elongation at break of UV stabilized HDPE/PP fabric after been exposed to UV radiation and weathering ) |
- |
10340 |
|
25% discount is not applicable in conditioning charges |
4.1 and Table 1 ix(Ash content ) |
- |
950 |
|
Nil |
|
31 Dec, 2026 |
- Included w.e.f. 29.06.2017. |