Search by IS Number
Reset
11896 Results
S.No. Lab Name Osl Code Indian Standard No. Product Grade / Type / Size / Designation etc. Testing Charges (Excl. Of Taxes) Validity Date Remark
10561 Matrix Test Labs 8138626 IS 16046 : Part 1 (2018) Secondary Cells and Batteries Containing Alkaline or Other Non-Acid Electrolytes ” Safety Requirements for Portable Sealed Secondary Cells and for Batteries Made from Them for Use in Portable Applications Part 1 Nickel Systems ( Second Revision ) - 180000 View breakup
-
31 Dec, 2026 -
REVISED VERSION Included w.e.f. 14.01.2019.
10562 CENTRAL INSTITUTE OF PETROCHEMICALS ENGINEERING AND TECHNOLOGY (CIPET):CSTS-BHOPAL 8100534 IS 13487 (1992) Irrigation equipment - Emitters - Specification - 4700 View breakup
-
31 Dec, 2026 -
-
10563 CENTRAL INSTITUTE OF PETROCHEMICALS ENGINEERING AND TECHNOLOGY (CIPET):CSTS-BHOPAL 8100534 IS 12818 (2010) Unplasticized polyvinyl chloride (Pvc - U) screen and casing pipes for bore/tubewells - Specification (Second Revision) - 14725 View breakup
-
31 Dec, 2026 -
-
10564 CENTRAL INSTITUTE OF PETROCHEMICALS ENGINEERING AND TECHNOLOGY (CIPET):CSTS-BHOPAL 8100534 IS 12786 (1989) Irrigation equipment - Polyethylene pipes for irrigation laterals - Specification - 9725.00 View breakup
-
31 Dec, 2026 -
EXCLUSION: Antioxidant test (Cl.4.1)
10565 BIS, Central Laboratory (CL) None IS 14494 (2019) Elastomer insulated flexible cables for use in mines - Specification (First Revision) - - View breakup
-
- -
EXCLUDING Ozone resistance test, dielectric pf test, Water Absorption Test, Heating cycle and partial discharge Test, High Voltage;
10566 BIS, Central Laboratory (CL) None IS 14845 (2000) Resilient seated cast iron air relief valves for water works purposes - specification - 4659 View breakup
Testing charges =15.5 x 300 + 1 x 9 = Rs. 4659.00 + testing charges as per relevant ISS.
- -
Since the composition of cast iron shall be left to the discretion ofthe manufacturer , as such element to be tested with specified requirement and tolerances if any may please be declared with method of testing. Sample Size 5 pcs of 5x5 cm having dia> 3mm and thickness > 0.8 mm.; EXCLUDING all except IS 318 : 1974, IS 320 : 1980; End Connection (Cl.8) for screwed connection, (Cl.12 )Testing and performance,
10567 BIS, Central Laboratory (CL) None IS 7142 (1995) Welded low carbon steel cylinders for low pressure liquifiable gases not exceeding 5 litre water capacity - Specification (First Revision) - Rs. 9552/- View breakup
-
- -
Sample size shall be minimum dia> 3mm and thickness > 0.8 mm; EXCLUDING "-; 16.1 Hydrostatic Stretch Test 10.3 Bung"
10568 BIS, Central Laboratory (CL) None IS 15905 (2011) Hubless centrifugally cast (Spun) iron pipes, fittings and accessories - Spigot series - Specification - Rs. 5745/ View breakup
-
- -
Since the composition of cast iron shall be left to the discretion ofthe manufacturer , as such element to be tested with specified requirement and tolerances if any may please be declared with method of testing. Sample Size 5 pcs of 5x5 cm having dia> 3mm and thickness > 0.8 mm.; EXCLUDING -; hydraulic test
10569 BIS, Central Laboratory (CL) None IS 444 (2017) Rubber hoses, textile - Reinforced, for general - Purpose water applications - Specification (Fifth Revision) - 8250 View breakup
Testing Charges for the product as per 444:2017/ISO 1403:2005 = 8250
- -
Excluding -; Test facility not available For Resistance to liquids, Burst test, Adhesion test, Ozone Test, Flexibility test
10570 BIS, Central Laboratory (CL) None IS 12701 (1996) Rotational moulded polyethylene water storage tanks - specification (First Revision) - 6900 View breakup
-
- -
Complete for Chemical, Total Surface Area in cm2 to be declared on Test request; Excluding : Available up to 2000 L capacity except for Flexural Modulus (Cl. 7.5);
10571 BIS, Central Laboratory (CL) None IS 1626 : Part 3 (1994) Asbestos Cement Building types and Pipe Fittings, Gutters and Gutter Fittings and Roofing Fittings - Part 3 : Roofing Fittings - Rs.3300.00 View breakup
-
- -
-
10572 BIS, Eastern Regional Laboratory (ERL) None IS 781 (1984) Specification for cast copper alloy screw down bib taps and stop valves for water services (Third Revision) For all sizes except for the tests mentioned in remarks Rs.2700/- View breakup
-
- -
Chem: Except Sn,Si,Mn,Al,Sb Mech: Except hydraulic test, thread measurement
10573 BIS, Central Laboratory (CL) None IS 5312 : Part 1 (2004) Swing Check Type Reflux (Non-Return] Valves for Water Works Purposes - Part 1 : Single-Door Pattern - Rs 5700/- View breakup
-
- -
-; Complete(up to 200 mm nominal size)
10574 BIS, Central Laboratory (CL) None IS 12330 (1988) Specificatioon for sulphate resisting Portland cement - Rs.12900/- View breakup
-
- -
complete for chemical; Excluding: -; Salphate Espansion
10575 BIS, Central Laboratory (CL) None IS 9763 (2000) Plastics Bib Taps, Pillar Taps, Angle Valves and Stop Valves for Hot and Cold Water Services - - Rs.7800/- View breakup
-
- -
-
10576 BIS, Central Laboratory (CL) None IS 9857 (1990) Welding cables - Specification (First Revision) - Rs 11400/- View breakup
-
- -
-
10577 BIS, Central Laboratory (CL) None IS 9758 (1981) Specification for flush valves and fittings for water closets and urinals - Rs. 1950/ View breakup
-
- -
Sample size shall be minimum dia> 3mm and thickness > 0.8 mm; Excluding: Complete for Material;
10578 BIS, Eastern Regional Laboratory (ERL) None IS 15658 (2006) Precast concrete blocks for paving - Specification - Rs.15940/- View breakup
-
- -
40 pcs Exclusion Except Freeze thaw durability test
10579 BIS, Central Laboratory (CL) None IS 1364 : Part 1 (2018) Hexagon head bolts, screws and nuts of product grades A and B: Part 1 hexagon head bolts (Size Range M 1.6 To M 64) (Fifth Revision) - - View breakup
-
- -
Excluding: -; cl4 &Table 3 except hardness test
10580 BIS, Central Laboratory (CL) None IS 9396 : Part 1 (1987) Specification for round open top sanitary cans for foods and drinks: Part 1 tinplate (First Revision) - Rs. 6883/- View breakup
-
- -
-
10581 BIS, Central Laboratory (CL) None IS 1363 : Part 3 (2018) Hexagon Head Bolts, Screws and Nuts of Product Grade ˜C ™ Part 3 (Style 1) Hexagon Nuts ( Size Range M 5 to M 64 ) ( Fifth Revision ) - - View breakup
-
- -
Excluding : -; cl4 &Table 3 except hardness test
10582 BIS, Central Laboratory (CL) None IS 13098 (2012) Automotive vehicles - Tubes for pneumatic tyres - Specification (First Revision) - Total Resting Charges : Rs. 13,050.00 View breakup
-
- -
-
10583 BIS, Central Laboratory (CL) None IS 8329 (2000) Centrifugally cast (Spun) ductile iron pressure pipes for water, gas and sewage - Specification (Third Revision) - Rs.7800/- View breakup
-
- -
-
10584 BIS, Central Laboratory (CL) None IS 10701 (2012) Structural plywood - Specification (First Revision) - 9600 View breakup
Rs.9600.00 + charges for as per referred ISs.
- -
Excluding : Test facility not available for Cl 11.7 Penals shear strength, Modulus of rigidity,Rolling shear strength cl.11.8 Static Bending Strength and Wet Bending Strength Above 15 mm thickness sample size required:A) Structural Plywood – 2 Sheets B) Face And Core Veneers, Cross-Bands – 2 Sheets Of Suitable Size Sample Size without dimensional measurements: Length-1800 mm, width-1200
10585 BIS, Central Laboratory (CL) None IS 784 (2019) Prestressed concrete pipes (Including Specials) - Specification (Third Revision) - - View breakup
-
- -
-
10586 BIS, Central Laboratory (CL) None IS 8035 (1999) Handpump - Shallow well - Specification (First Revision) - Rs. 8850/- View breakup
-
- -
-
10587 BIS, Central Laboratory (CL) None IS 4003 : Part 1 (1978) Specification for pipe wrenches: Part 1 general purpose (First Revision) - Rs. 3600/- and testing charges as per referred Iss View breakup
-
- -
Sample size shall be minimum dia> 3mm and thickness > 0.8 mm; Excluding : Complete for Component material;
10588 BIS, Central Laboratory (CL) None IS 650 (1991) Standard sand for testing cement - Specification (Second Revision) - Rs 1500.00 View breakup
-
- -
complete for chemical;
10589 BIS, Central Laboratory (CL) None IS 9968 : Part 2 (2002) Specification for elastomer - Insulated cables: Part 2 for working voltages from 3.3 kV up to and including 33 kV (First Revision) - Rs. 14450/ View breakup
-
- -
EXCLUDING Water absorption test, partial discharge test, impulse test, dielectric pf test, heating cycle, and HV test;
10590 BIS, Central Laboratory (CL) None IS 7834 : Part 1 (1987) injection moulded PVC socket fittings with solvent cement joints for water supplies: Part 1 General requirements - Rs.2400/- View breakup
-
- -
EXCLUDING Test facility not available for Cl. 6.4 Short Term Hydraulic Test;

Designed, Developed and Maintained by:

Arohatech IT Services (P) Ltd.

Contact for any query/support: supportlims@bis.gov.in