| 12211 |
National Metallurgical Laboratory Unit, Chennai
| 6107814
| IS 1573 (1986) |
Specification for electroplated coatings of zinc on iron and steel (Second Revision) |
- |
- View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
No Record Found
|
|
- |
- (Lab of national repute and eminence, facilities of which are being utilized by BIS.) |
| 12212 |
National Metallurgical Laboratory Unit, Chennai
| 6107814
| IS 4736 (1986) |
Specification for hot - Dip zinc coatings on mild steel tubes (Fist Revision) |
- |
- View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
No Record Found
|
|
- |
- (Lab of national repute and eminence, facilities of which are being utilized by BIS.) |
| 12213 |
Northern India Textile Research Association (NITRA), Ghaziabad
| 8163504
| IS 758 (1988) |
Specification for cotton gauze, absorbent, non-sterilized (fourth revision) |
- |
- View breakup
Rs.3300/- Plus 18% GST
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
No Record Found
|
|
- |
- (Lab of national repute and eminence, facilities of which are being utilized by BIS.) |
| 12214 |
National Test House (NR) - NTH, Ghaziabad
| 8101304
| IS 1554 : Part 1 (1988) |
Specification for pvc insulated (Heavy Duty) electric cables: Part 1 for working voltages up to and including 1100 v (Third Revision) |
- |
6000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 6.2(MATERIALS : ARMGURING) |
- |
3000 |
|
- |
| 13.6 e)(ARMOURING: Uniformity of zinc coating) |
- |
1000 |
|
- |
| 13.6 f)(ARMOURING: Mass of zinc coating ) |
- |
1000 |
|
- |
| 16.5(Oxygen Index Test) |
- |
1000 |
|
- |
| 16.1(Temperature Index) |
- |
1000 |
|
- |
| 16.9(Test for Halogen Acid Gas Evolution) |
- |
1000 |
|
- |
|
26 Oct, 2025 |
- - |
| 12215 |
Central Power Research Institute (CPRI), Bangalore
| 6101024
| IS 1554 : Part 1 (1988) |
Specification for pvc insulated (Heavy Duty) electric cables: Part 1 for working voltages up to and including 1100 v (Third Revision) |
1 to 5 cores/FR/FRLS Sheath |
336500 View breakup
1 Core PVC Insulated & Sheathed armoured Cable Rs. 87300 /- + 18 % GST
1 Core PVC Insulated & FR PVC Sheathed armoured Cable Rs. 159800 /-+ 18 % GST
1 Core PVC Insulated & FR LSH PVC Sheathed armoured Cable Rs. 187810+ 18 % GST
2 Core PVC Insulated sheathed armoured Cable Rs. 139330 /-+ 18 % GST
2 Core PVC Insulated & FR PVC Sheathed armoured Cable Rs. 211550 /-+ 18 % GST
2 Core PVC Insulated & FR - LSH PVC Sheathed armoured Cable Rs. 239560 /-+ 18 % GST
3 Core PVC Insulated Sheathed armoured Cable Rs. 171350 /-+ 18 % GST
3 Core PVC Insulated & FR PVC Sheathed armoured Cable Rs. 250090 /-+ 18 % GST
1 core PVC Insulated & FR-LSH PVC Sheathed armoured Cable Rs. 271860 /- + 18 % GST 4 Core PVC Insulated sheathed armoured Cable Rs. 202300 /-+ 18 % GST
4 Core PVC Insulated & FR PVC Sheathed armoured Cable Rs. 274800 /-+ 18 % GST
4 Core PVC Insulated & FR - LSH PVC Sheathed armoured Cable Rs. 302810 /- + 18 % GST
5 Core PVC Insulated sheathed armoured Cable Rs. 240020 /-+ 18 % GST
5 or more PVC Insulated & FR PVC Sheathed armoured Cable Rs. 3125250 /-+ 18 % GST
5 or more Core PVC Insulated & FR-LSH PVC sheathed armoured Cable Rs. 340530 /-+ 18 % GST
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 3.1(MATERIALS : CONDUCTOR) |
- |
0 |
|
The complete test charges applicable, will be intimated through proforma invoice. |
| 4.1.1(INSULATION : General Purjose Insulaiion) |
- |
0 |
|
The complete test charges applicable, will be intimated through proforma invoice. |
| 4.1.2(INSULATION : Heat Resisting Insulation) |
- |
0 |
|
The complete test charges applicable, will be intimated through proforma invoice. |
| 5.1(MATERIALS : FILLER AND INNER SHEATH) |
- |
0 |
|
The complete test charges applicable, will be intimated through proforma invoice. |
| 5.2(MATERIALS : FILLER AND INNER SHEATH) |
- |
0 |
|
The complete test charges applicable, will be intimated through proforma invoice. |
| 6.1(MATERIALS : ARMGURING) |
- |
0 |
|
The complete test charges applicable, will be intimated through proforma invoice. |
| 6.2(MATERIALS : ARMGURING) |
- |
0 |
|
The complete test charges applicable, will be intimated through proforma invoice. |
| 7.1.1(OUTER SHEATH : For Cables with General Purpose InsuIafion) |
- |
0 |
|
The complete test charges applicable, will be intimated through proforma invoice. |
| 7.1.2(OUTER SHEATH : For Cables with Heat Resisting InsuIalion) |
- |
0 |
|
The complete test charges applicable, will be intimated through proforma invoice. |
| 8.1(CONSTRUCTION : CONDUCTOR) |
- |
0 |
|
The complete test charges applicable, will be intimated through proforma invoice. |
| 8.2(CONSTRUCTION : CONDUCTOR) |
- |
0 |
|
The complete test charges applicable, will be intimated through proforma invoice. |
| 9.1(INSULATION ) |
- |
0 |
|
The complete test charges applicable, will be intimated through proforma invoice. |
| 9.2(INSULATION : Thickness of Insulation) |
- |
500 |
|
The test charges is applicable for one core and if the number core increases, test charges will also increase proportionally.
The complete test charges applicable, will be intimated through proforma invoice. |
| 9.3(INSULATION :Tolerance on Thickness of Insulation) |
- |
0 |
|
The complete test charges applicable, will be intimated through proforma invoice. |
| 9.4(INSULATION : Application of Insulation) |
- |
0 |
|
The complete test charges applicable, will be intimated through proforma invoice. |
| 10.1(CORE IDENTIFICATION) |
- |
0 |
|
The complete test charges applicable, will be intimated through proforma invoice. |
| 10.2(CORE IDENTIFICATION) |
- |
0 |
|
The complete test charges applicable, will be intimated through proforma invoice. |
| 10.3(CORE IDENTIFICATION) |
- |
0 |
|
The complete test charges applicable, will be intimated through proforma invoice. |
| 10.3.1(Arrangement of Marking) |
- |
0 |
|
The complete test charges applicable, will be intimated through proforma invoice. |
| 11.1(LAYING UP OF CORES) |
- |
0 |
|
The complete test charges applicable, will be intimated through proforma invoice. |
| 11.2(LAYING UP OF CORES) |
- |
0 |
|
The complete test charges applicable, will be intimated through proforma invoice. |
| 12.1(INNER SHEATH) |
- |
0 |
|
The complete test charges applicable, will be intimated through proforma invoice. |
| 12.2(INNER SHEATH) |
- |
0 |
|
The complete test charges applicable, will be intimated through proforma invoice. |
| 12.3(INNER SHEATH :Thickness of Inner Sheath) |
- |
500 |
|
The test charges is applicable for one core and if the number core increases, test charges will also increase proportionally.
The complete test charges applicable, will be intimated through proforma invoice. |
| 12.3.1(INNER SHEATH :Thickness of Inner Sheath) |
- |
500 |
|
The test charges is applicable for one core and if the number core increases, test charges will also increase proportionally.
The complete test charges applicable, will be intimated through proforma invoice. |
| 13.1.1(ARMOURING : Application) |
- |
0 |
|
The complete test charges applicable, will be intimated through proforma invoice. |
| 13.1.2(Armouring: Coverage ) |
- |
0 |
|
The complete test charges applicable, will be intimated through proforma invoice. |
| 13.1.3(ARMOURING : Direction of lay ) |
- |
0 |
|
The complete test charges applicable, will be intimated through proforma invoice. |
| 13.1.4(ARMOURING : Application) |
- |
0 |
|
The complete test charges applicable, will be intimated through proforma invoice. |
| 13.2(ARMOURING : Type of Armour) |
- |
0 |
|
The complete test charges applicable, will be intimated through proforma invoice. |
| 13.2.1(ARMOURING : Type of Armour) |
- |
0 |
|
The complete test charges applicable, will be intimated through proforma invoice. |
| 13.3(Armouring : Dimensions -Wire Diameter) |
- |
500 |
|
The complete test charges applicable, will be intimated through proforma invoice. |
| 13.3(Armouring : Dimensions -Formed wire ) |
- |
500 |
|
The complete test charges applicable, will be intimated through proforma invoice. |
| 13.4(ARMOURING : Joints) |
- |
0 |
|
The complete test charges applicable, will be intimated through proforma invoice. |
| 13.5.1(ARMOURING : Resistance) |
- |
2300 |
|
The complete test charges applicable, will be intimated through proforma invoice. |
| 13.5.2(ARMOURING : Resistance) |
- |
2300 |
|
The complete test charges applicable, will be intimated through proforma invoice. |
| 13.6 a)(ARMOURING: Tensile Strength) |
- |
2350 |
|
The complete test charges applicable, will be intimated through proforma invoice. |
| 13.6 b)(ARMOURING: Elongation ) |
- |
2350 |
|
The complete test charges applicable, will be intimated through proforma invoice. |
| 13.6 c)(ARMOURING: Torsion Test (For round wire ) ) |
- |
500 |
|
The complete test charges applicable, will be intimated through proforma invoice. |
| 13.6 d)(ARMOURING: Winding Test(For formed wire)) |
- |
500 |
|
The complete test charges applicable, will be intimated through proforma invoice. |
| 13.6 e)(ARMOURING: Uniformity of zinc coating) |
- |
700 |
|
The complete test charges applicable, will be intimated through proforma invoice. |
| 13.6 f)(ARMOURING: Mass of zinc coating ) |
- |
700 |
|
The complete test charges applicable, will be intimated through proforma invoice. |
| 13.6 g)(ARMOURING: Resistivity) |
- |
2300 |
|
The complete test charges applicable, will be intimated through proforma invoice. |
| 14.1(OUTER SHEATH) |
- |
0 |
|
The complete test charges applicable, will be intimated through proforma invoice. |
| 14.2(OUTER SHEATH) |
- |
0 |
|
The complete test charges applicable, will be intimated through proforma invoice. |
| 14.3(OUTER SHEATH : Colour ) |
- |
0 |
|
The complete test charges applicable, will be intimated through proforma invoice. |
| 14.4.1(Thickness of Outer Sheath : Unarmowed Cables) |
- |
500 |
|
The complete test charges applicable, will be intimated through proforma invoice. |
| 14.4.2(Thickness of Outer Sheath : Armoured Cables) |
- |
500 |
|
The complete test charges applicable, will be intimated through proforma invoice. |
| 15.1 a) 1)(Tests on conductor : Annealing test ( for copper )) |
- |
1450 |
|
The test charges is applicable for one core and if the number core increases, test charges will also increase proportionally.
The complete test charges applicable, will be intimated through proforma invoice. |
| 15.1 a) 2)(Tensile test (for aluminium) - Before stranding ) |
- |
2350 |
|
The complete test charges applicable, will be intimated through proforma invoice. |
| 15.1 a) 2)(Tensile test (for aluminium) - After stranding ) |
- |
2350 |
|
The complete test charges applicable, will be intimated through proforma invoice. |
| 15.1 a) 3)(Tests on conductor : Wrapping test ( for aluminium )) |
- |
500 |
|
The test charges is applicable for one core and if the number core increases, test charges will also increase proportionally.
The complete test charges applicable, will be intimated through proforma invoice. |
| 15.1 a) 4)(Tests on conductor : Conductor resistance test) |
- |
2300 |
|
The test charges is applicable for one core and if the number core increases, test charges will also increase proportionally.
The complete test charges applicable, will be intimated through proforma invoice. |
| 15.1 a) 4)(Resistance test - Neutral conductor ) |
- |
2300 |
|
The complete test charges applicable, will be intimated through proforma invoice. |
| 15.1 d)1)(Phyaical tests for insulation : Tensile Test) |
- |
2350 |
|
The test charges is applicable for one core and if the number core increases, test charges will also increase proportionally.
The complete test charges applicable, will be intimated through proforma invoice. |
| 15.1 d)1)(Phyaical tests for insulation : Elongation ) |
- |
2350 |
|
The test charges is applicable for one core and if the number core increases, test charges will also increase proportionally.
The complete test charges applicable, will be intimated through proforma invoice. |
| 15.1 d)1)(Physical tests for sheath : Tensile stregth ) |
- |
2350 |
|
The complete test charges applicable, will be intimated through proforma invoice. |
| 15.1 d)1)(Physical tests for sheath : Elongation ) |
- |
2350 |
|
The complete test charges applicable, will be intimated through proforma invoice. |
| 15.1 d)2)(Phyaical tests for insulation- Ageing in air Oven : Tensile Test) |
- |
5300 |
|
Ageing charges for all the insulation.
The complete test charges applicable, will be intimated through proforma invoice. |
| 15.1 d)2)(Phyaical tests for insulation - Ageing in air oven : Elongation ) |
- |
0 |
|
Ageing charges for all the insulation.
The complete test charges applicable, will be intimated through proforma invoice. |
| 15.1 d)2)(Phyaical tests for insulation- Ageing in air oven : Elongation Variation ) |
- |
0 |
|
The complete test charges applicable, will be intimated through proforma invoice. |
| 15.1 d)2)(Phyaical tests for insulation - Ageing in air Oven : Tensile Variation ) |
- |
0 |
|
The complete test charges applicable, will be intimated through proforma invoice. |
| 15.1 d)2)(Physical tests for outer sheath- Ageing in air oven : Tensile stregth ) |
- |
5300 |
|
The complete test charges applicable, will be intimated through proforma invoice. |
| 15.1 d)2)(Physical tests for outer sheath -Ageing in air oven : Elongation ) |
- |
0 |
|
The complete test charges applicable, will be intimated through proforma invoice. |
| 15.1 d)2)(Physical tests for outer sheath- Ageing in air oven : Tensile stregth Variation ) |
- |
0 |
|
The complete test charges applicable, will be intimated through proforma invoice. |
| 15.1 d)2)(Physical tests for outer sheath -Ageing in air oven : Elongation Variation ) |
- |
0 |
|
The complete test charges applicable, will be intimated through proforma invoice. |
| 15.1 d)3)(Phyaical tests for insulation : Shrinkage ) |
- |
1000 |
|
The test charges is applicable for one core and if the number core increases, test charges will also increase proportionally.
The complete test charges applicable, will be intimated through proforma invoice. |
| 15.1 d)3)(Phyaical tests for insulation : Shrinkage - Crack observed ) |
- |
0 |
|
The complete test charges applicable, will be intimated through proforma invoice. |
| 15.1 d)3)(Phyaical tests for Sheath : Shrinkage ) |
- |
1000 |
|
The complete test charges applicable, will be intimated through proforma invoice. |
| 15.1 d)3)(Phyaical tests for Sheath : Shrinkage - Crack observed ) |
- |
0 |
|
The complete test charges applicable, will be intimated through proforma invoice. |
| 15.1 d)4)(Hot deformation : Insulation ) |
- |
2200 |
|
The test charges is applicable for one core and if the number core increases, test charges will also increase proportionally.
The complete test charges applicable, will be intimated through proforma invoice. |
| 15.1 d)4)(Hot deformation : Sheath ) |
- |
2200 |
|
The complete test charges applicable, will be intimated through proforma invoice. |
| 15.1 d)5)( Loss of mass in air oven- Insulation ) |
- |
5300 |
|
The test charges is applicable for one core and if the number core increases, test charges will also increase proportionally.
The complete test charges applicable, will be intimated through proforma invoice. |
| 15.1 d)5)( Loss of mass in air oven- sheath ) |
- |
5300 |
|
The complete test charges applicable, will be intimated through proforma invoice. |
| 15.1 d)6)(Heat shock test- Insulation ) |
- |
1000 |
|
The test charges is applicable for one core and if the number core increases, test charges will also increase proportionally.
The complete test charges applicable, will be intimated through proforma invoice. |
| 15.1 d)6)(Heat shock test- sheath ) |
- |
1000 |
|
The complete test charges applicable, will be intimated through proforma invoice. |
| 15.1 d)7)(Thermal stability- insulation ) |
- |
3000 |
|
The test charges is applicable for one core and if the number core increases, test charges will also increase proportionally.
The complete test charges applicable, will be intimated through proforma invoice. |
| 15.1 d)7)(Thermal stability- Sheath ) |
- |
3000 |
|
The complete test charges applicable, will be intimated through proforma invoice. |
| 15.1 e)(Insulation resistance test : Volume Resistivity ) |
- |
0 |
|
The complete test charges applicable, will be intimated through proforma invoice. |
| 15.1 e)(Insulation resistance test : IR Constant ) |
- |
1100 |
|
The test charges is applicable for one core and if the number core increases, test charges will also increase proportionally.
The complete test charges applicable, will be intimated through proforma invoice. |
| 15.1 f)(High voltage test ( water immersion test )) |
- |
12450 |
|
The complete test charges applicable, will be intimated through proforma invoice. |
| 15.1 g)(High voltage test at room temperature) |
- |
1300 |
|
The test charges is applicable for one core and if the number core increases, test charges will also increase proportionally.
The complete test charges applicable, will be intimated through proforma invoice. |
| 15.4 a)(Cold bend test- Insulation ( Optional test)) |
- |
12100 |
|
The test charges is applicable for one core and if the number core increases, test charges will also increase proportionally.
The complete test charges applicable, will be intimated through proforma invoice. |
| 15.4 a)(Cold bend test- Sheath ( Optional test)) |
- |
7600 |
|
The complete test charges applicable, will be intimated through proforma invoice. |
| 15.4 b)(Cold impact test- Insulation ( Optional test)) |
- |
12100 |
|
The test charges is applicable for one core and if the number core increases, test charges will also increase proportionally.
The complete test charges applicable, will be intimated through proforma invoice. |
| 15.4 b)(Cold impact test- Sheath ( Optional test)) |
- |
7600 |
|
The complete test charges applicable, will be intimated through proforma invoice. |
| 15.4 c)(Armour resistance test ( for other than mining cables ).- Optional test ) |
- |
18450 |
|
The test charges quoted is applicable for the complete tests on Armour.
The complete test charges applicable, will be intimated through proforma invoice. |
| 16.1(DETAILS OF TESTS : General) |
- |
0 |
|
The complete test charges applicable, will be intimated through proforma invoice. |
| 16.2(DETAILS OF TESTS : High Voltage Test at Room Temperature) |
- |
1300 |
|
The test charges is applicable for one core and if the number core increases, test charges will also increase proportionally.
The complete test charges applicable, will be intimated through proforma invoice. |
| 16.3.1(High Voltage Test ( Water Immersion Test ) : a.c. Test) |
- |
12450 |
|
The complete test charges applicable, will be intimated through proforma invoice. |
| 16.3.2(High Voltage Test ( Water Immersion Test ) : d.c. Test) |
- |
12450 |
|
The complete test charges applicable, will be intimated through proforma invoice. |
| 16.4(Flammability Test) |
- |
1600 |
|
The complete test charges applicable, will be intimated through proforma invoice. |
| 16.5(Oxygen Index Test) |
- |
10300 |
|
The complete test charges applicable, will be intimated through proforma invoice. |
| 16.6(Flame Retardance Test on Single Cables) |
- |
2300 |
|
The complete test charges applicable, will be intimated through proforma invoice. |
| 16.7(Flame Retardance Test on Bunched Cables) |
- |
36500 |
|
Applicable for Category B or C |
| 16.9(Test for Halogen Acid Gas Evolution) |
- |
10300 |
|
The complete test charges applicable, will be intimated through proforma invoice. |
| 16.1(Temperature Index) |
- |
11700 |
|
The complete test charges applicable, will be intimated through proforma invoice. |
| 17.1(IDENTIFICATION : Manufacturer’s Identification) |
- |
0 |
|
The complete test charges applicable, will be intimated through proforma invoice. |
| 17.2(IDENTIFICATION : Cable Identification) |
- |
0 |
|
The complete test charges applicable, will be intimated through proforma invoice. |
| 17.2.1(IDENTIFICATION : Cable Identification) |
- |
0 |
|
The complete test charges applicable, will be intimated through proforma invoice. |
| 17.3(IDENTIFICATION : Cable Code) |
- |
0 |
|
The complete test charges applicable, will be intimated through proforma invoice. |
| 15.1.e(Insulation resistance Test- Insulation resistance At Maximum rated temperature temperature) |
- |
1600 |
|
The test charges is applicable for one core and if the number core increases, test charges will also increase proportionally.
The complete test charges applicable, will be intimated through proforma invoice. |
| 15.1.e(Insulation resistance Test- Volume Resistivity At Maximum rated temperature temperature) |
- |
0 |
|
The complete test charges applicable, will be intimated through proforma invoice. |
| 15.1.e(Insulation resistance Test- Volume Resistivity At Room temperature) |
- |
0 |
|
The complete test charges applicable, will be intimated through proforma invoice. |
| 16.4(Flammability Test- Un affected portion) |
- |
0 |
|
The complete test charges applicable, will be intimated through proforma invoice. |
| 16.4(Flammability Test- Period of Burning) |
- |
0 |
|
The complete test charges applicable, will be intimated through proforma invoice. |
| 9.3(Minimum Thickness of Reduce core insulation) |
- |
500 |
|
The complete test charges applicable, will be intimated through proforma invoice.0 |
| 3.1 Table 2
IS 8130(Number of wires in the conductor) |
- |
0 |
|
The complete test charges applicable, will be intimated through proforma invoice. |
| Cl No. 16.10(Smoke density test) |
- |
14550 |
|
The complete test charges applicable, will be intimated through proforma invoice. |
| Cl No. 16.8(Test for specific optical density of smoke) |
- |
0 |
|
The complete test charges applicable, will be intimated through proforma invoice. |
| Table 4(Copper purity test) |
- |
0 |
|
The complete test charges applicable, will be intimated through proforma invoice. |
| 15.4 (b)(Cold impact) |
- |
7600 |
|
The complete test charges applicable, will be intimated through proforma invoice. |
|
31 Dec, 2026 |
- - |
| 12216 |
Central Power Research Institute (CPRI), Bangalore
| 6101024
| IS 1554 : Part 2 (1988) |
Specification for pvc insulated (Heavy Duty) electric cables: Part 2 for working voltages from 3.3 kV up to and including 11 kV (Second Revision) |
- |
445550 View breakup
Rs.199700/- + 18% GST for 1-core (except FRLS tests); Rs.292500/- + 18% GST for 1-core (FRLS cable); Rs.419650/- + 18% GST for 3-core (except FRLS tests); Rs.512400/- + 18% GST for 3-core (FRLS cables);
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 3.1(CONDUCTOR) |
- |
0 |
|
The complete test charges applicable will be intimated through proforma invoice. |
| 3.1.1(CONDUCTOR) |
- |
0 |
|
The complete test charges applicable will be intimated through proforma invoice. |
| 4.1(INSULATION) |
- |
0 |
|
The complete test charges applicable will be intimated through proforma invoice. |
| 5.1(SCREENING) |
- |
0 |
|
The complete test charges applicable will be intimated through proforma invoice. |
| 5.1.1(Non-magnetic Metallic Tape for SingleCore Unscreened and Unarmoured Cables) |
- |
0 |
|
The complete test charges applicable will be intimated through proforma invoice. |
| 6.1(FILLERS AND INNER SHEATH) |
- |
0 |
|
The complete test charges applicable will be intimated through proforma invoice. |
| 6.2(FILLERS AND INNER SHEATH) |
- |
0 |
|
The complete test charges applicable will be intimated through proforma invoice. |
| 7.1(ARMOURING) |
- |
0 |
|
The complete test charges applicable will be intimated through proforma invoice. |
| 7.2(ARMOURING) |
- |
0 |
|
The complete test charges applicable will be intimated through proforma invoice. |
| 8.1(OUTER SHEATH) |
- |
0 |
|
The complete test charges applicable will be intimated through proforma invoice. |
| 9.1(CONDUCTOR) |
- |
0 |
|
The complete test charges applicable will be intimated through proforma invoice. |
| 9.2(CONDUCTOR) |
- |
0 |
|
The complete test charges applicable will be intimated through proforma invoice. |
| 10.1(CONDUCTOR SCREENING) |
- |
0 |
|
The complete test charges applicable will be intimated through proforma invoice. |
| 11.1(INSULATION) |
- |
0 |
|
The complete test charges applicable will be intimated through proforma invoice. |
| 11.2(INSULATION : Thickness of Insulation) |
- |
500 |
|
The test charges quoted is for one core and the test charges proportionally increases when the number of cores are more.
The complete test charges applicable will be intimated through proforma invoice. |
| 11.3(INSULATION : Tolerance on Thickness of Insulation) |
- |
0 |
|
The complete test charges applicable will be intimated through proforma invoice. |
| 11.4(INSULATION : Application of Insulation) |
- |
0 |
|
The complete test charges applicable will be intimated through proforma invoice. |
| 12.1(INSULATION SCREENING) |
- |
0 |
|
The complete test charges applicable will be intimated through proforma invoice. |
| 12.2(INSULATION SCREENING) |
- |
0 |
|
The complete test charges applicable will be intimated through proforma invoice. |
| 12.3(INSULATION SCREENING) |
- |
0 |
|
The complete test charges applicable will be intimated through proforma invoice. |
| 12.4(INSULATION SCREENING) |
- |
0 |
|
The complete test charges applicable will be intimated through proforma invoice. |
| 13.1(CORE IDENTIFICATION) |
- |
0 |
|
The complete test charges applicable will be intimated through proforma invoice. |
| 13.1.1(CORE IDENTIFICATION) |
- |
0 |
|
The complete test charges applicable will be intimated through proforma invoice. |
| 14.1(LAYING UP OF CORES) |
- |
0 |
|
The complete test charges applicable will be intimated through proforma invoice. |
| 15.1(INNER SHEATH (COMMON COVERING)) |
- |
0 |
|
The complete test charges applicable will be intimated through proforma invoice. |
| 15.2(INNER SHEATH (COMMON COVERING)) |
- |
0 |
|
The complete test charges applicable will be intimated through proforma invoice. |
| 15.3(INNER SHEATH (COMMON COVERING)) |
- |
0 |
|
The complete test charges applicable will be intimated through proforma invoice. |
| 15.4(INNER SHEATH (COMMON COVERING) : Thickness of Inner Sheath) |
- |
500 |
|
The complete test charges applicable will be intimated through proforma invoice. |
| 15.4.1(INNER SHEATH (COMMON COVERING) : Thickness of Inner Sheath) |
- |
500 |
|
The complete test charges applicable will be intimated through proforma invoice. |
| 16.1.1(ARMOURING : Application) |
- |
0 |
|
The complete test charges applicable will be intimated through proforma invoice. |
| 16.1.2(ARMOURING : Application) |
- |
0 |
|
The complete test charges applicable will be intimated through proforma invoice. |
| 16.1.3(ARMOURING : Direction of lay ) |
- |
0 |
|
The complete test charges applicable will be intimated through proforma invoice. |
| 16.1.4(ARMOURING : Application) |
- |
0 |
|
The complete test charges applicable will be intimated through proforma invoice. |
| 16.2.1(ARMOURING : Type of Armour) |
- |
0 |
|
The complete test charges applicable will be intimated through proforma invoice. |
| 16.2.2(ARMOURING : Type of Armour) |
- |
0 |
|
The complete test charges applicable will be intimated through proforma invoice. |
| 16.3(Armouring : Dimensions -Wire Diameter) |
- |
850 |
|
The complete test charges applicable will be intimated through proforma invoice. |
| 16.3(Armouring : Dimensions -Formed wire ) |
- |
850 |
|
The complete test charges applicable will be intimated through proforma invoice. |
| 16.4(ARMOURING : Joints) |
- |
0 |
|
The complete test charges applicable will be intimated through proforma invoice. |
| 16.5(ARMOURING : Resistance) |
- |
2300 |
|
The complete test charges applicable will be intimated through proforma invoice. |
| 13.6 a)(ARMOURING: Tensile Strength) |
- |
18450 |
|
Test quoted charges is applicable for all the tests on armour.
The complete test charges applicable will be intimated through proforma invoice. |
| 13.6 b)(ARMOURING: Elongation ) |
- |
0 |
|
The complete test charges applicable will be intimated through proforma invoice. |
| 13.6 c)(ARMOURING: Torsion Test (For round wire ) ) |
- |
0 |
|
The complete test charges applicable will be intimated through proforma invoice. |
| 13.6 d)(ARMOURING: Winding Test(For formed wire)) |
- |
0 |
|
The complete test charges applicable will be intimated through proforma invoice. |
| 13.6 e)(ARMOURING: Uniformity of zinc coating) |
- |
0 |
|
The complete test charges applicable will be intimated through proforma invoice. |
| 13.6 f)(ARMOURING: Mass of zinc coating ) |
- |
0 |
|
The complete test charges applicable will be intimated through proforma invoice. |
| 13.6 g)(ARMOURING: Resistivity) |
- |
0 |
|
The complete test charges applicable will be intimated through proforma invoice. |
| 17.1(OUTER SHEATH) |
- |
0 |
|
The complete test charges applicable will be intimated through proforma invoice. |
| 17.2(OUTER SHEATH : colour ) |
- |
0 |
|
The complete test charges applicable will be intimated through proforma invoice. |
| 17.3.1(Thickness of Outer Sheath : Unarmoured Cables) |
- |
500 |
|
The complete test charges applicable will be intimated through proforma invoice. |
| 17.3.2(Thickness of Outer Sheath : Armoured Cables) |
- |
500 |
|
The complete test charges applicable will be intimated through proforma invoice. |
| 18.1 a) 1)(Tests on Conductor : Annealing test (for copper)) |
- |
1450 |
|
The test charges quoted is for one core and the test charges proportionally increases when the number of cores are more.
The complete test charges applicable will be intimated through proforma invoice. |
| 18.1 a) 2)(Tensile test (for aluminium) - Before stranding ) |
- |
3100 |
|
The complete test charges applicable will be intimated through proforma invoice. |
| 18.1 a) 2)(Tensile test (for aluminium) - After stranding ) |
- |
3100 |
|
The complete test charges applicable will be intimated through proforma invoice. |
| 18.1 a) 3)(Tests on Conductor : Wrapping test ( for aluminium)) |
- |
500 |
|
The test charges quoted is for one core and the test charges proportionally increases when the number of cores are more.
The complete test charges applicable will be intimated through proforma invoice. |
| 18.1 a)4)(Tests on conductor : Conductor resistance test - Main conductor ) |
- |
2300 |
|
The test charges quoted is for one core and the test charges proportionally increases when the number of cores are more.
The complete test charges applicable will be intimated through proforma invoice. |
| 18.1 a)4)(Resistance test - Neutral conductor ) |
- |
2300 |
|
The complete test charges applicable will be intimated through proforma invoice. |
| 18.1 d) 1)(Phyaical tests for insulation : Tensile Test) |
- |
3100 |
|
The test charges quoted is for one core and the test charges proportionally increases when the number of cores are more.
The complete test charges applicable will be intimated through proforma invoice. |
| 18.1 d) 1)(Phyaical tests for insulation : Elongation ) |
- |
3100 |
|
The test charges quoted is for one core and the test charges proportionally increases when the number of cores are more.
The complete test charges applicable will be intimated through proforma invoice. |
| 18.1 d) 2)(Phyaical tests for insulation- Ageing in air Oven : Tensile Test) |
- |
5300 |
|
Ageing test charges is for all the insulation.
The complete test charges applicable will be intimated through proforma invoice. |
| 18.1 d) 2)(Phyaical tests for insulation - Ageing in air oven : Elongation ) |
- |
0 |
|
Ageing test charges is for all the insulation.
The complete test charges applicable will be intimated through proforma invoice. |
| 18.1 d) 2)(Phyaical tests for insulation - Ageing in air Oven : Tensile Variation ) |
- |
0 |
|
Ageing test charges is for all the insulation.
The complete test charges applicable will be intimated through proforma invoice. |
| 18.1 d) 2)(Phyaical tests for insulation- Ageing in air oven : Elongation Variation ) |
- |
0 |
|
Ageing test charges is for all the insulation.
The complete test charges applicable will be intimated through proforma invoice. |
| 18.1 d) 2)(Physical tests for outer sheath- Ageing in air oven : Tensile stregth ) |
- |
5300 |
|
The complete test charges applicable will be intimated through proforma invoice. |
| 18.1 d) 2)(Physical tests for outer sheath -Ageing in air oven : Elongation ) |
- |
0 |
|
The complete test charges applicable will be intimated through proforma invoice. |
| 18.1 d) 2)(Physical tests for outer sheath- Ageing in air oven : Tensile stregth Variation ) |
- |
0 |
|
The complete test charges applicable will be intimated through proforma invoice. |
| 18.1 d) 2)(Physical tests for outer sheath -Ageing in air oven : Elongation Variation ) |
- |
0 |
|
The complete test charges applicable will be intimated through proforma invoice. |
| 18.1 d) 3)(Phyaical tests for insulation : Shrinkage ) |
- |
1000 |
|
The test charges quoted is for one core and the test charges proportionally increases when the number of cores are more.
The complete test charges applicable will be intimated through proforma invoice. |
| 18.1 d) 3)(Phyaical tests for insulation : Shrinkage - Crack observed ) |
- |
0 |
|
The test charges quoted is for one core and the test charges proportionally increases when the number of cores are more.
The complete test charges applicable will be intimated through proforma invoice. |
| 18.1 d) 3)(Phyaical tests for Sheath : Shrinkage ) |
- |
1000 |
|
The complete test charges applicable will be intimated through proforma invoice. |
| 18.1 d) 3)(Phyaical tests for Sheath : Shrinkage - Crack observed ) |
- |
0 |
|
The complete test charges applicable will be intimated through proforma invoice. |
| 18.1 d) 4)(Hot deformation : Insulation ) |
- |
2200 |
|
The test charges quoted is for one core and the test charges proportionally increases when the number of cores are more.
The complete test charges applicable will be intimated through proforma invoice. |
| 18.1 d) 4)(Hot deformation : Sheath ) |
- |
2200 |
|
The complete test charges applicable will be intimated through proforma invoice. |
| 18.1 d) 5)( Loss of mass in air oven- Insulation ) |
- |
5300 |
|
The test charges quoted is for one core and the test charges proportionally increases when the number of cores are more.
The complete test charges applicable will be intimated through proforma invoice. |
| 18.1 d) 5)( Loss of mass in air oven- sheath ) |
- |
5300 |
|
The complete test charges applicable will be intimated through proforma invoice. |
| 18.1 d) 6)(Heat shock test- Insulation ) |
- |
1000 |
|
The test charges quoted is for one core and the test charges proportionally increases when the number of cores are more.
The complete test charges applicable will be intimated through proforma invoice. |
| 18.1 d) 6)(Heat shock test- sheath ) |
- |
1000 |
|
The test charges quoted is for one core and the test charges proportionally increases when the number of cores are more.
The complete test charges applicable will be intimated through proforma invoice. |
| 18.1 d) 7)(Thermal stability- insulation ) |
- |
3000 |
|
The test charges quoted is for one core and the test charges proportionally increases when the number of cores are more.
The complete test charges applicable will be intimated through proforma invoice. |
| 18.1 d) 7)(Thermal stability- Sheath ) |
- |
3000 |
|
The complete test charges applicable will be intimated through proforma invoice. |
| 18.1 d) 8)(Water absorption (gravimetric)(for insulation, where applicable)) |
- |
16100 |
|
The complete test charges applicable will be intimated through proforma invoice. |
| 18.1 e)(Insulation resistance test : Volume Resistivity ) |
- |
1100 |
|
The test charges quoted is for one core and the test charges proportionally increases when the number of cores are more.
The complete test charges applicable will be intimated through proforma invoice. |
| 18.1 e)(Insulation resistance test : IR Constant ) |
- |
1600 |
|
The test charges quoted is for one core and the test charges proportionally increases when the number of cores are more.
The complete test charges applicable will be intimated through proforma invoice. |
| 19.2(Partial discharge test) |
- |
4000 |
|
The test charges quoted is for one core and the test charges proportionally increases when the number of cores are more.
The complete test charges applicable will be intimated through proforma invoice. |
| 19.3(Bending test) |
- |
5700 |
|
The complete test charges applicable will be intimated through proforma invoice. |
| 19.4(Dielectric power factor test) |
- |
2300 |
|
The test charges quoted is for one core and the test charges proportionally increases when the number of cores are more.
The complete test charges applicable will be intimated through proforma invoice. |
| 19.4(Dielectric power factor test) |
- |
3750 |
|
The test charges quoted is for one core and the test charges proportionally increases when the number of cores are more.
The complete test charges applicable will be intimated through proforma invoice. |
| 19.5(Heating cycle test) |
- |
2000 |
|
The test charges quoted is for one cycle of heating cycle test.
The complete test charges applicable will be intimated through proforma invoice. |
| 19.6(Impulse withstand test) |
- |
19750 |
|
The test charges quoted is for one core and the test charges proportionally increases when the number of cores are more.
The complete test charges applicable will be intimated through proforma invoice. |
| 19.7(High voltage test) |
- |
5200 |
|
The test charges quoted is for one core and the test charges proportionally increases when the number of cores are more.
The complete test charges applicable will be intimated through proforma invoice. |
| 19.8(Flammability test) |
- |
1600 |
|
The complete test charges applicable will be intimated through proforma invoice. |
| 19.9(Oxygen Index Test) |
- |
10300 |
|
The complete test charges applicable will be intimated through proforma invoice. |
| 19.10(Flame Retardance Test on Single Cables) |
- |
2300 |
|
The complete test charges applicable will be intimated through proforma invoice. |
| 19.11(Flame Retardance Test on Bunched Cables) |
- |
36500 |
|
The quoted charges is applicable for Category B or C.
The complete test charges applicable will be intimated through proforma invoice. |
| 19.13(Test for Halogen Acid Gas Evolution) |
- |
10300 |
|
The complete test charges applicable will be intimated through proforma invoice. |
| 19.14(Temperature Index) |
- |
11700 |
|
The complete test charges applicable will be intimated through proforma invoice. |
| 18.4(Optional Test : Cold Impact ) |
- |
7600 |
|
The complete test charges applicable will be intimated through proforma invoice. |
| 20.1(IDENTIFICATION : Manufacturer's Identification) |
- |
0 |
|
The complete test charges applicable will be intimated through proforma invoice. |
| 20.2(IDENTIFICATION : Cable Identification) |
- |
0 |
|
The complete test charges applicable will be intimated through proforma invoice. |
| 20.3(IDENTIFICATION : Cable Code) |
- |
0 |
|
The complete test charges applicable will be intimated through proforma invoice. |
| 15.4 (b)(Cold impact) |
- |
7600 |
|
The complete test charges applicable will be intimated through proforma invoice. |
|
31 Dec, 2026 |
- - |
| 12217 |
Central Power Research Institute (CPRI), Bangalore
| 6101024
| IS 7098 : Part 1 (1988) |
Specification for crosslinked polyethylene insulated pvc sheathed cables: Part 1 for working voltages up to and including 1100 volts (First Revision) |
- |
261300 View breakup
1 Core XLPE Insulated and PVC Sheathed armoured Cable Rs. 92180 /- + 18 % GST
1 Core XLPE Insulated and FR PVC Sheathed armoured Cable Rs. 164680 /- + 18 % GST
1 Core XLPE Insulated and FR-LSH PVC Sheathed armoured Cable Rs. 192690 /- + 18 % GST
2 Core XLPE Insulated and PVC Sheathed armoured Cable Rs. 131870/- + 18 % GST
2 Core XLPE Insulated and FR PVC Sheathed armoured Cable Rs. 204370 /- + 18 % GST
2 Core XLPE Insulated and FR- LSH PVC Sheathed armoured Cable Rs. 232380 /- + 18 % GST
3 Core XLPE Insulated and PVC Sheathed armoured Cable Rs. 161410 /- + 18 % GST
3 Core XLPE Insulated and FR PVC Sheathed armoured Cable Rs.233910 /- + 18 % GST
3 Core XLPE Insulated and FR- LSH PVC Sheathed armoured Cable Rs.261920 /- + 18 % GST
4 Core XLPE Insulated and PVC Sheathed armoured Cable Rs. 189240 /- + 18 % GST
4 Core XLPE Insulated and FR PVC Sheathed armoured Cable Rs. 261740 /- + 18 % GST
4 Core XLPE Insulated and FR -LSH PVC Sheathed armoured Cable Rs. 285220/- + 18 % GST
5 or more core XLPE Insulated and PVC Sheathed armoured Cable Rs. 221800 /- + 18 % GST
5 or more core XLPE Insulated and FR PVC Sheathed armoured cable Rs. 300510 /- + 18 % GST
5 or more core XLPE Insulated and FR-LSH PVC Sheathed armoured Cable Rs. 317170 /- + 18 % GST
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 3(CONDUCTOR: MATERIALS) |
- |
0 |
|
The complete test charges applicable, will be intimated through proforma invoice. |
| 4(INSULATION : MATERIALS) |
- |
0 |
|
The complete test charges applicable, will be intimated through proforma invoice. |
| 5.1(FILLER AND INNER SHEATH) |
- |
0 |
|
The complete test charges applicable, will be intimated through proforma invoice. |
| 5.2(FILLER AND INNER SHEATH) |
- |
0 |
|
The complete test charges applicable, will be intimated through proforma invoice. |
| 6(ARMOURING) |
- |
0 |
|
The complete test charges applicable, will be intimated through proforma invoice. |
| 7(OUTER SHEATH) |
- |
0 |
|
The complete test charges applicable, will be intimated through proforma invoice. |
| 8.1(CONDUCTOR: CONSTRUCTION) |
- |
0 |
|
The complete test charges applicable, will be intimated through proforma invoice. |
| 8.2(PROTECTIVE BARRIER) |
- |
0 |
|
The complete test charges applicable, will be intimated through proforma invoice. |
| 8.3(SIZE OF NEUTRAL CONDUCTOR) |
- |
0 |
|
The complete test charges applicable, will be intimated through proforma invoice. |
| 9.1(Insulation Applied by extrusicn) |
- |
0 |
|
The complete test charges applicable, will be intimated through proforma invoice. |
| 9.2(Thickness of Insulation - Average) |
- |
800 |
|
The complete test charges applicable, will be intimated through proforma invoice. |
| 9.3(Thickness of Insulation - Minimum) |
- |
0 |
|
The test charges indicated is applicable for one core and if the number of cores are more proportionally the charges will increase.
The complete test charges applicable, will be intimated through proforma invoice. |
| 9.4(Application of Insulation) |
- |
0 |
|
The test charges indicated is applicable for one core and if the number of cores are more proportionally the charges will increase.
The complete test charges applicable, will be intimated through proforma invoice. |
| 10.1(Core Identification) |
- |
0 |
|
The complete test charges applicable, will be intimated through proforma invoice. |
| 10.2(Core Identification- Neutral) |
- |
0 |
|
The complete test charges applicable, will be intimated through proforma invoice. |
| 10.3(Core Identification by number ) |
- |
0 |
|
The complete test charges applicable, will be intimated through proforma invoice. |
| 10.4(Core Identification by number - Neutral ) |
- |
0 |
|
The complete test charges applicable, will be intimated through proforma invoice. |
| 11(LAVING UP OF CORES) |
- |
0 |
|
The complete test charges applicable, will be intimated through proforma invoice. |
| 12.1 & 12.2(Inner sheath : Application) |
- |
0 |
|
The complete test charges applicable, will be intimated through proforma invoice. |
| 12.3(Thickness of Inner Sheath) |
- |
800 |
|
The test charges indicated is applicable for one core and if the number of cores are more proportionally the charges will increase.
The complete test charges applicable, will be intimated through proforma invoice. |
| 13.1(Armouring: Application) |
- |
0 |
|
The complete test charges applicable, will be intimated through proforma invoice. |
| 13.1.2(Armouring: Coverage ) |
- |
0 |
|
The complete test charges applicable, will be intimated through proforma invoice. |
| 13.1.3(Armouring: Direction of Lay ) |
- |
0 |
|
The complete test charges applicable, will be intimated through proforma invoice. |
| 13.2(Type of armour ) |
- |
0 |
|
The complete test charges applicable, will be intimated through proforma invoice. |
| 13.3(Armouring : Dimensions -Wire Diameter) |
- |
500 |
|
The complete test charges applicable, will be intimated through proforma invoice. |
| 13.3(Armouring : Dimensions -Formed wire ) |
- |
500 |
|
The complete test charges applicable, will be intimated through proforma invoice. |
| 13.4(Armour: Joint) |
- |
0 |
|
The complete test charges applicable, will be intimated through proforma invoice. |
| 13.5(Armouring : Resistance Test) |
- |
2300 |
|
The complete test charges applicable, will be intimated through proforma invoice. |
| 13.6 a)(ARMOURING: Tensile Strength) |
- |
5300 |
|
The complete test charges applicable, will be intimated through proforma invoice. |
| 13.6 b)(ARMOURING: Elongation ) |
- |
5300 |
|
The complete test charges applicable, will be intimated through proforma invoice. |
| 13.6 c)(ARMOURING: Torsion Test (For round wire ) ) |
- |
500 |
|
The complete test charges applicable, will be intimated through proforma invoice. |
| 13.6 d)(ARMOURING: Winding Test(For formed wire)) |
- |
500 |
|
The complete test charges applicable, will be intimated through proforma invoice. |
| 13.6 e)(ARMOURING: Uniformity of zinc coating) |
- |
700 |
|
The complete test charges applicable, will be intimated through proforma invoice. |
| 13.6 f)(ARMOURING: Mass of zinc coating ) |
- |
700 |
|
The complete test charges applicable, will be intimated through proforma invoice. |
| 13.6 g)(ARMOURING: Resistivity) |
- |
2300 |
|
The complete test charges applicable, will be intimated through proforma invoice. |
| 14.1(Outer Sheath : Application) |
- |
0 |
|
The complete test charges applicable, will be intimated through proforma invoice. |
| 14.2(Colour of outer sheath) |
- |
0 |
|
The complete test charges applicable, will be intimated through proforma invoice. |
| 14.3(Thickness of outer sheath - AVERAGE) |
- |
800 |
|
The complete test charges applicable, will be intimated through proforma invoice. |
| 14.3(Thickness of outer sheath - minimum) |
- |
0 |
|
The complete test charges applicable, will be intimated through proforma invoice. |
| 15.1 a) i)(Annealing Test ( For copper wire ) ) |
- |
1450 |
|
The test charges indicated is applicable for one core and if the number of cores are more proportionally the charges will increase.
The complete test charges applicable, will be intimated through proforma invoice. |
| 15.1 a) ii)(Tensile test (for aluminium) - Before stranding ) |
- |
5300 |
|
The test charges indicated is applicable for one core and if the number of cores are more proportionally the charges will increase.
The complete test charges applicable, will be intimated through proforma invoice. |
| 15.1 a) ii)(Tensile test (for aluminium) - After stranding ) |
- |
5300 |
|
The test charges indicated is applicable for one core and if the number of cores are more proportionally the charges will increase.
The complete test charges applicable, will be intimated through proforma invoice. |
| 15.1 a) iii)(Wrapping test (for aluminium)) |
- |
500 |
|
The test charges indicated is applicable for one core and if the number of cores are more proportionally the charges will increase.
The complete test charges applicable, will be intimated through proforma invoice. |
| 15.1 a) iv)(Resistance test - Main conductor) |
- |
2300 |
|
The test charges indicated is applicable for one core and if the number of cores are more proportionally the charges will increase.
The complete test charges applicable, will be intimated through proforma invoice. |
| 15.1 a) iv)(Resistance test - Neutral conductor) |
- |
2300 |
|
The complete test charges applicable, will be intimated through proforma invoice. |
| 15.1 d) i) (Phyaical tests for insulation : Tensile Test) |
- |
5300 |
|
The test charges indicated is applicable for one core and if the number of cores are more proportionally the charges will increase.
The complete test charges applicable, will be intimated through proforma invoice. |
| 15.1 d) i) (Phyaical tests for insulation : Elongation) |
- |
5300 |
|
The test charges indicated is applicable for one core and if the number of cores are more proportionally the charges will increase.
The complete test charges applicable, will be intimated through proforma invoice. |
| 15.1 d) ii) (Phyaical tests for insulation - Ageing in air Oven : Tensile Variation ) |
- |
5300 |
|
The complete test charges applicable, will be intimated through proforma invoice. |
| 15.1 d) ii) (Phyaical tests for insulation- Ageing in air oven : Elongation Variation ) |
- |
0 |
|
The complete test charges applicable, will be intimated through proforma invoice. |
| 15.1 d) iii) (Phyaical tests for insulation : Hot set ) |
- |
2300 |
|
The test charges indicated is applicable for one core and if the number of cores are more proportionally the charges will increase.
The complete test charges applicable, will be intimated through proforma invoice. |
| 15.1 d) iii) (Phyaical tests for insulation : Permanent set ) |
- |
0 |
|
The complete test charges applicable, will be intimated through proforma invoice. |
| 15.1 d) iv) (Phyaical tests for insulation : Shrinkage ) |
- |
1000 |
|
The test charges indicated is applicable for one core and if the number of cores are more proportionally the charges will increase.
The complete test charges applicable, will be intimated through proforma invoice. |
| 15.1 e) iv) (Phyaical tests for Sheath : Shrinkage - Crack observed ) |
- |
0 |
|
The complete test charges applicable, will be intimated through proforma invoice. |
| 15.1 e) v) (Sheath : Hot deformation) |
- |
2200 |
|
The complete test charges applicable, will be intimated through proforma invoice. |
| 15.1 e) vi) (Sheath : Heat shock test) |
- |
1000 |
|
The complete test charges applicable, will be intimated through proforma invoice. |
| 15.1 e) vii) (Sheath : Thermalstability) |
- |
3000 |
|
The complete test charges applicable, will be intimated through proforma invoice. |
| 15.1 f)(INSULATION RESISTANCE TEST : Volume resistivity ) |
- |
1100 |
|
The test charges indicated is applicable for one core and if the number of cores are more proportionally the charges will increase.
The complete test charges applicable, will be intimated through proforma invoice. |
| 16.2(HIGH VOLTAGE TEST ) |
- |
1300 |
|
The test charges indicated is applicable for one core and if the number of cores are more proportionally the charges will increase.
The complete test charges applicable, will be intimated through proforma invoice. |
| 16.3(FLAMMABILITY TEST : Period of Burning ) |
- |
1600 |
|
The complete test charges applicable, will be intimated through proforma invoice. |
| 16.3(FLAMMABILITY TEST : Unaffected length ) |
- |
0 |
|
The complete test charges applicable, will be intimated through proforma invoice. |
| 16.9(Oxygen Index Test) |
- |
10300 |
|
The complete test charges applicable, will be intimated through proforma invoice. |
| 16.1(Flame Retardance Test on Single Cables) |
- |
2300 |
|
The complete test charges applicable, will be intimated through proforma invoice. |
| 16.11(Flame Retardance Test on Bunched Cables) |
- |
36500 |
|
Charges applicable for Category B or C.
The complete test charges applicable, will be intimated through proforma invoice. |
| 16.13(Test for Halogen Acid Gas Evolution) |
- |
10300 |
|
The complete test charges applicable, will be intimated through proforma invoice. |
| 16.14(Temperature Index) |
- |
11700 |
|
The complete test charges applicable, will be intimated through proforma invoice. |
| 17.1(Manufacturer'. identification) |
- |
0 |
|
The complete test charges applicable, will be intimated through proforma invoice. |
| 17.2(cable Indentification ) |
- |
0 |
|
The complete test charges applicable, will be intimated through proforma invoice. |
| 17.3(cable Code ) |
- |
0 |
|
The complete test charges applicable, will be intimated through proforma invoice. |
| 15.4 (a)(Cold bend) |
- |
12100 |
|
The test charges indicated is applicable for one core and if the number of cores are more proportionally the charges will increase.
The complete test charges applicable, will be intimated through proforma invoice. |
| Table 1(Ageing in air oven - Elongation on Insulation) |
- |
5300 |
|
The complete test charges applicable, will be intimated through proforma invoice. |
| Table 1(Ageing in air oven - Tensile strength on Insulation) |
- |
0 |
|
The complete test charges applicable, will be intimated through proforma invoice. |
| Table 1(Ageing in air oven - Elongation on Insulation) |
- |
0 |
|
The complete test charges applicable, will be intimated through proforma invoice. |
| Table 1(Ageing in air oven - Tensile strength on Insulation) |
- |
0 |
|
The complete test charges applicable, will be intimated through proforma invoice. |
| Table 4(Copper purity test) |
- |
0 |
|
The complete test charges applicable, will be intimated through proforma invoice. |
| Cl No. 16.15(Smoke density test) |
- |
14550 |
|
The complete test charges applicable, will be intimated through proforma invoice. |
| Table 2(Cold Impact test for Outer sheath) |
- |
7600 |
|
The test charges indicated is applicable for one core and if the number of cores are more proportionally the charges will increase.
The complete test charges applicable, will be intimated through proforma invoice. |
| Table 2(Cold bend test for Outer sheath) |
- |
12100 |
|
The complete test charges applicable, will be intimated through proforma invoice. |
| 15.4 (b)(Cold impact) |
- |
7600 |
|
The complete test charges applicable, will be intimated through proforma invoice. |
|
31 Dec, 2026 |
- - |
| 12218 |
Central Power Research Institute (CPRI), Bangalore
| 6101024
| IS 9968 : Part 1 (1988) |
Specification for elastomer insulatedcables: Part 1 for working voltages up to and including 1100 volts (First Revision) |
- |
320200 View breakup
Rs.164350/- + 18% GST for 1-core; Rs.300270/- + 18% GST for 3-core; Rs.368230/- + 18% GST for 4-core
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 3.1( Copper Cooduetor) |
- |
0 |
|
The complete test charges applicable will be intimated through proforma invoice. |
| 3.2(Aluminium conductor) |
- |
0 |
|
The complete test charges applicable will be intimated through proforma invoice. |
| 4.1(INSULATION : lnsulation for General Service) |
- |
0 |
|
The complete test charges applicable will be intimated through proforma invoice. |
| 4.2(INSULATION : Heat Resisting insulation) |
- |
0 |
|
The complete test charges applicable will be intimated through proforma invoice. |
| 4.3(INSULATION : Silicone Rubber Insulation) |
- |
0 |
|
The complete test charges applicable will be intimated through proforma invoice. |
| 5.1(TAPE : Proofed Tape) |
- |
0 |
|
The complete test charges applicable will be intimated through proforma invoice. |
| 5.2(TAPE : 2 Polyethyl_ Terephthalate ( PETP ) Tape or
Plastic: Tape or Any Other SlIIitable Tape ) |
- |
0 |
|
The complete test charges applicable will be intimated through proforma invoice. |
| 5.3(TAPE : Giass Tape) |
- |
0 |
|
The complete test charges applicable will be intimated through proforma invoice. |
| 6.1(FILLERS : ) |
- |
0 |
|
The complete test charges applicable will be intimated through proforma invoice. |
| 7.1(BRAID : Textile Braid) |
- |
0 |
|
The complete test charges applicable will be intimated through proforma invoice. |
| 7.2(BRAID : Glass Braid ) |
- |
0 |
|
The complete test charges applicable will be intimated through proforma invoice. |
| 8.1(SHEATH : General Service Insulated Cables and Flexible
Cords) |
- |
0 |
|
The complete test charges applicable will be intimated through proforma invoice. |
| 8.2(SHEATH :Heat Resisting Insulated Cables) |
- |
0 |
|
The complete test charges applicable will be intimated through proforma invoice. |
| 9.1(PresenRtive Compound) |
- |
0 |
|
The complete test charges applicable will be intimated through proforma invoice. |
| 9.2(Varnish) |
- |
0 |
|
The complete test charges applicable will be intimated through proforma invoice. |
| 10( Conductor ) |
- |
0 |
|
The complete test charges applicable will be intimated through proforma invoice. |
| 11(Separator tape) |
- |
0 |
|
The complete test charges applicable will be intimated through proforma invoice. |
| 12.2(Insulation : Thickness of Insufatien) |
- |
1600 |
|
The test charges is applicable for one core and if the number core increases, test charges will also increase proportionally.
The complete test charges applicable will be intimated through proforma invoice. |
| 12.4(Insulation : Allplication of Insulation) |
- |
0 |
|
The complete test charges applicable will be intimated through proforma invoice. |
| 13(CORE IDENTiFICATlON) |
- |
0 |
|
The complete test charges applicable will be intimated through proforma invoice. |
| 14(Tape) |
- |
0 |
|
The complete test charges applicable will be intimated through proforma invoice. |
| 15(BRAIDING) |
- |
0 |
|
The complete test charges applicable will be intimated through proforma invoice. |
| 16(COMPOUNDING AND VARNISHING) |
- |
0 |
|
The complete test charges applicable will be intimated through proforma invoice. |
| 17(LAYING UP OF CORES) |
- |
0 |
|
The complete test charges applicable will be intimated through proforma invoice. |
| 18( Binder tape) |
- |
0 |
|
The complete test charges applicable will be intimated through proforma invoice. |
| 19.2(Sheath : Thickness of Sheath) |
- |
1600 |
|
The complete test charges applicable will be intimated through proforma invoice. |
| 19.4( Sheath :Colour) |
- |
0 |
|
The complete test charges applicable will be intimated through proforma invoice. |
| 20( Overall diameter) |
- |
1600 |
|
The complete test charges applicable will be intimated through proforma invoice. |
| 21. (a)(Persulphate tests (for copper)) |
- |
2300 |
|
The complete test charges applicable will be intimated through proforma invoice. |
| 21. (b)(Annealing Test (for coper)) |
- |
1450 |
|
The test charges is applicable for one core and if the number core increases, test charges will also increase proportionally.
The complete test charges applicable will be intimated through proforma invoice. |
| 21. (c)( Tensile Test (for aluminium)) |
- |
5300 |
|
The test charges is applicable for one core and if the number core increases, test charges will also increase proportionally.
The complete test charges applicable will be intimated through proforma invoice. |
| 21. (d)( Wrapping Test (for aluminium)) |
- |
500 |
|
The test charges is applicable for one core and if the number core increases, test charges will also increase proportionally.
The complete test charges applicable will be intimated through proforma invoice. |
| 21. (e)(Conductor Resistance ) |
- |
2300 |
|
The test charges is applicable for one core and if the number core increases, test charges will also increase proportionally.
The complete test charges applicable will be intimated through proforma invoice. |
| 21.1( Tensile strength ) |
- |
6200 |
|
The test charges is applicable for one core and if the number core increases, test charges will also increase proportionally.
The complete test charges applicable will be intimated through proforma invoice. |
| 22.1( Elongation) |
- |
6200 |
|
The test charges is applicable for one core and if the number core increases, test charges will also increase proportionally.
The complete test charges applicable will be intimated through proforma invoice. |
| 21.1(type test : Ageing In air oven) |
- |
5300 |
|
The complete test charges applicable will be intimated through proforma invoice. |
| 21.1(type test : Ageing in air bomb) |
- |
10300 |
|
The complete test charges applicable will be intimated through proforma invoice. |
| 21.1(type test : Ageing In oxygen
bomb) |
- |
10300 |
|
The complete test charges applicable will be intimated through proforma invoice. |
| 21.1(type test : Hot set elongation) |
- |
2300 |
|
The test charges is applicable for one core and if the number core increases, test charges will also increase proportionally.
The complete test charges applicable will be intimated through proforma invoice. |
| 21.1(type test : Tear resistance ) |
- |
5300 |
|
The test charges is applicable for one core and if the number core increases, test charges will also increase proportionally.
The complete test charges applicable will be intimated through proforma invoice. |
| 22.2(type test :Insulauon resistance High voltage (water immersron ) test) |
- |
2700 |
|
The test charges is applicable for one core and if the number core increases, test charges will also increase proportionally.
The complete test charges applicable will be intimated through proforma invoice. |
| 22.2(type test : Flammability test
( applicable to cables
finished With SE 3 and
SE 4 sheaths only)
) |
- |
1600 |
|
The complete test charges applicable will be intimated through proforma invoice. |
| 21(Water absorption test) |
- |
16100 |
|
The complete test charges applicable will be intimated through proforma invoice. |
| 23(identification) |
- |
0 |
|
The complete test charges applicable will be intimated through proforma invoice. |
| Cl No. 4.1(Ageing in oxygen bomb - Elongation) |
- |
6200 |
|
The test charges is applicable for one core and if the number core increases, test charges will also increase proportionally.
The complete test charges applicable will be intimated through proforma invoice. |
| Cl No. 4.1(Ageing in oxygen bomb - Tensile strength ) |
- |
6200 |
|
The test charges is applicable for one core and if the number core increases, test charges will also increase proportionally.
The complete test charges applicable will be intimated through proforma invoice. |
| Cl No. 4.1(Ageing in air bomb - Elongation) |
- |
6200 |
|
The test charges is applicable for one core and if the number core increases, test charges will also increase proportionally.
The complete test charges applicable will be intimated through proforma invoice. |
| Cl No. 4.1(Ageing in air bomb - Tensile strength ) |
- |
6200 |
|
The test charges is applicable for one core and if the number core increases, test charges will also increase proportionally.
The complete test charges applicable will be intimated through proforma invoice. |
| Cl No. 4.1(Ageing in air oven - Elongation) |
- |
5300 |
|
The complete test charges applicable will be intimated through proforma invoice. |
| Cl No. 4.1(Ageing in air oven - Tensile strength ) |
- |
6200 |
|
The test charges is applicable for one core and if the number core increases, test charges will also increase proportionally.
The complete test charges applicable will be intimated through proforma invoice. |
| Cl No. 22.2(High Voltage Test (Water Immersion)) |
- |
12450 |
|
The complete test charges applicable will be intimated through proforma invoice. |
| Cl No. 4.1(Insulation resistance) |
- |
2700 |
|
The test charges is applicable for one core and if the number core increases, test charges will also increase proportionally.
The complete test charges applicable will be intimated through proforma invoice. |
| Cl No. 22.4, Appendix B (Flexing test for cords for use with electric iron ) |
- |
7400 |
|
The complete test charges applicable will be intimated through proforma invoice. |
| Cl No. 22.2.2/22.2.3(High Voltage Test / Spark test) |
- |
5200 |
|
The test charges is applicable for one core and if the number core increases, test charges will also increase proportionally.
The complete test charges applicable will be intimated through proforma invoice. |
| Cl No. 23.1, 23.2(Identification) |
- |
0 |
|
The complete test charges applicable will be intimated through proforma invoice. |
| 15.4 (b)(Cold impact) |
- |
7600 |
|
The complete test charges applicable will be intimated through proforma invoice. |
|
31 Dec, 2026 |
- - |
| 12219 |
National Test House (NR) - NTH, Ghaziabad
| 8101304
| IS 303 (1989) |
Plywood for General Purposes - |
Grade BWR/Type AA/AB/BB |
13000 View breakup
For BIS samples: BIS approved testing charges, for others: Rs.13000/-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 11.4, Table 4(Static Bending Strength - Modulus of Rupture - Across the Face Grain - Minimum Individual) |
- |
0 |
|
- |
| 11.4, Table 4(Static Bending Strength - Modulus of Rupture - Across the Face Grain - Average) |
- |
750 |
|
- |
| 11.4, Table 4(Static Bending Strength - Modulus of Rupture - Along the Face Grain - Minimum Individual) |
- |
0 |
|
- |
| 11.4, Table 4(Static Bending Strength - Modulus of Rupture - Along the Face Grain - Average) |
- |
750 |
|
- |
| 11.4, Table 4(Static Bending Strength - Modulus of Elasticity - Across the Face Grain - Minimum Individual) |
- |
0 |
|
- |
| 11.4, Table 4(Static Bending Strength - Modulus of Elasticity - Across the Face Grain - Average) |
- |
750 |
|
- |
| 11.4, Table 4(Static Bending Strength - Modulus of Elasticity - Along the Face Grain - Minimum Individual) |
- |
0 |
|
- |
| 11.4, Table 4(Static Bending Strength - Modulus of Elasticity - Along the Face Grain - Average) |
- |
750 |
|
- |
| 11.2.2(Glue Adhesion - Mycological test - 11.2.2, Part 7 of IS 1734 [for MR Garde only]) |
- |
1500 |
|
- |
| 11.2.1(Glue Adhesion - Water resistance test - 11.2.1.1 [for MR Grade]) |
- |
3000 |
|
- |
| 11.2.1(Glue Adhesion - Water resistance test - 11.2.1.1 [for BWR Grade]) |
- |
3000 |
|
- |
| 11.3(Moisture Content - Part 1 of IS 1734) |
- |
1000 |
|
- |
| 8(Dimensions & Tolerances - Edge Straightness - Annexure C) |
- |
500 |
|
- |
| 8(Dimensions & Tolerances - Squareness - Annexure C) |
- |
500 |
|
- |
| 8(Dimensions & Tolerances - Thickness - Cl. 8) |
- |
500 |
|
- |
| 8(Dimensions & Tolerances - Width - Cl. 8) |
- |
500 |
|
- |
| 8(Dimensions & Tolerances - Length - Cl. 8) |
- |
500 |
|
- |
| 9(Workmanship and Finish - Cl.9, 8.3, Annexure C) |
- |
0 |
|
- |
| 9(Workmanship and Finish - Cl.9, 8.3, Annexure C) |
- |
0 |
|
- |
| 5.2, Table 1, Table 2(Quality Requirements - Cl. 5.2) |
- |
1000 |
|
- |
| 5.1(Type - For BB Type) |
- |
0 |
|
- |
| 5.1(Type - For AB Type) |
- |
0 |
|
- |
| 5.1(Type - For AA Type) |
- |
0 |
|
- |
| 4(Grade - For MR grade) |
- |
0 |
|
- |
| 4(Grade - For BWR grade) |
- |
0 |
|
- |
|
26 Oct, 2025 |
- - |
| 12220 |
NATIONAL SUGAR INSTITUTE, KANPUR
| 9164114
| IS 12923 (1990) |
Cane gur (Jaggery) - Specification |
- |
- View breakup
Sucrose%-Rs.750/-, Reducing sugars-Rs.500/-, Moisture-Rs.500/-, Water Insoluble matter-Rs.600/-, Sulphated Ash-Rs.500/-, Sulphite/Sulphur Dioxide-Rs.500/-, Ash in soluble in HCL-Rs.500/-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
No Record Found
|
|
- |
- (Lab of national repute and eminence, facilities of which are being utilized by BIS.) |
| 12221 |
MSME Testing Centre, New Delhi
| 8101204
| IS 204 : Part 1 (1991) |
Tower bolts - Specification: Part 1 ferrous metals (Fifth Revision) |
- |
3300 View breakup
Rs.3300/- (10% concession for BIS)
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 5.1(General) |
- |
300 |
|
- |
| 5.2.1 Table 1(Particulars-Barrel Tower Bolts) |
- |
500 |
|
- |
| 5.2.2 Table 2(Particulars-Sami Barrel Tower Bolts) |
- |
300 |
|
- |
| 5.2.3 Table 3(Particulars-Riveted or Spot Welded Tower Bolts) |
- |
300 |
|
- |
| 5.2.4 Table 4(Particulars-Skeleton Tower Bolts) |
- |
300 |
|
- |
| 6.1- Table 1(Dimension of Barrel tower bolts-1.Size 2.Length of Bolt-A 3.Length of Barrel-B 4.Width of Barrel-C 5.Dia of Bolt-D 6.Length of Socket-E 7.Thickness of mild steel sheet for barrel-F 8.Dia of bore of barrel or socket- G ) |
- |
300 |
|
- |
| 6.2- Table 2(Dimension of Sami Barrel Tower Bolts 1.Size 2.Length of Bolt-A 3.Length of Bolt Plate-B 4.Width of Bolt Plate-C 5.Dia of Bolt-D 6.Length of Socket-E 7.Thickness of Bolt Plate or Socket-F 8.Dia of bore of Bolt Plate or socket G ) |
- |
300 |
|
- |
| 6.3- Table 3(Dimension of Riveted or Spot Welded Tower Bolts- 1.Size 2.Length of Bolt-A 3.Length of Bolt Plate-B 4.Width of Bolt Plate-C 5.Dia of Bolt-D 6.Length of Socket-E 7. Length of Strap-E" 8.Thickness of Back Plate -F 9.Thickness of Socket or Upper Plate and Strap- F" 10.Dia of bore of Bolt Plate or socket- G 11. Length of Alternative Socket-H ) |
- |
300 |
|
- |
| 6.4- Table 4(Dimension of Skeleton Tower Bolts 1.Size 2.Length of Bolt-A 3.Length of Bolt Plate-B 4.Width of Bolt Plate-C 5.Dia of Bolt-D 6.Length of Staple-E 7.Thickness of Plate or Staple -F 8.Dia of bore of Plate or Staple-G 9.Dia of shank of Knob-J) |
- |
300 |
|
- |
| 6.1- Table 1(Dimension of Barrel tower bolts-Minimum No. of equally Spaced Screw holes in Barrel and Socket for wood screw no 6) |
- |
300 |
|
- |
| 6.2- Table 2(Dimension of Sami Barrel Tower Bolts-Minimum No. of equally Spaced Screw holes in Bolt Plate and Socket for wood screw no 6) |
- |
300 |
|
- |
| 6.3- Table 3(Dimension of Riveted or Spot Welded Tower Bolts-Minimum No. of equally Spaced Screw holes in Bolt Plate and Socket for wood screw no 6) |
- |
300 |
|
- |
| 6.4- Table 4(Dimension of Skeleton Tower Bolts-Minimum No. of Screw holes for wood screw no 6) |
- |
300 |
|
- |
|
31 Dec, 2026 |
- - |
| 12222 |
MSME Testing Centre, New Delhi
| 8101204
| IS 366 (1991) |
Electric iron - Specification (Fourth Revision) |
- |
20000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 9.0(Protection against access to live parts (as per Cl. 8 of IS 302-2-3 and IS 302-1)) |
- |
2500 |
|
- |
| 9.0(Power input and current (as per Cl. 10 of IS 302-2-3 and IS 302-1)) |
- |
2500 |
|
- |
| 9.0(Temperature Rise (as per Cl. 11 of IS 302-2-3 and IS 302-1)) |
- |
3000 |
|
- |
| 9.0(Leakage current and Electric Strength at Operating Temperature (as per Cl. 13 of IS 302-2-3 and IS 302-1)) |
- |
4000 |
|
- |
| 9.0(Transient Overvoltage (as per of Cl. 14 of IS 302-2-3 and Table 6 of IS 302-1)) |
- |
2000 |
|
- |
| 9.0(Moisture Resistance (as per of Cl.15 of IS 302-2-3 and IS 302-1)) |
- |
2000 |
|
- |
| 7.0(Classification (as per Cl.6 of IS 302-2-3 and Cl.6.1 of IS 302-1)) |
- |
2000 |
|
- |
| 9.0(Abnormal Operation (as per of Cl.19 of IS 302-2-3 and IS 302-1) ) |
- |
2000 |
|
- |
| 9.0(Staibilty and mechanical hazards (as per of Cl.20 of IS 302-2-3 and IS 302-1) ) |
- |
5000 |
|
- |
| 9.0(Mechanical strength (as per of Cl.21 of IS 302-2-3 and IS 302-1) ) |
- |
2000 |
|
- |
| 9.0(Supply connection and external flexible cord (as per of Cl.25 of IS 302-2-3 and IS 302-1) ) |
- |
2000 |
|
- |
| 9.0(Terminals for external conductors (as per of Cl.26 of IS 302-2-3 and IS 302-1) ) |
- |
2000 |
|
- |
| 9.0(Provision for earthing (as per of Cl.27 of IS 302-2-3 and IS 302-1) ) |
- |
2000 |
|
- |
| 9.0(Screw and connections (as per of Cl.28 of IS 302-2-3 and IS 302-1)) |
- |
2000 |
|
- |
| 9.0(Resistance to Heat and Fire (as per of Cl.30 of IS 302-2-3 and IS 302-1)) |
- |
4000 |
|
- |
| 9.0(Resistance to Rusting (as per of Cl.31 of IS 302-2-3 and IS 302-1)) |
- |
2500 |
|
- |
| 9.0(Clearances, creepage distances and solid insulation (as per of Cl.29 of IS 302-2-3 and IS 302-1)) |
- |
2500 |
|
- |
| 10.0(Measurement of Heating up time) |
- |
5000 |
|
- |
| 11.0(Measurement of sole plate temperature) |
- |
5000 |
|
- |
| 12.0(Measurement of Tempearture Distribution) |
- |
5000 |
|
- |
| 13.0(Measurement of Initial overswing temperature and Heating up excess temperature) |
- |
5000 |
|
- |
| 14.0(Measurement of Cyclic fluctuation of temperature of hottest point ) |
- |
5000 |
|
- |
| 16.0(Measurement of Thermostatic staibility) |
- |
5000 |
|
- |
|
31 Dec, 2026 |
- Excl: Cl.19.11.4.1 to Cl.19.11.4.7 (EMI/EMC Test) |
| 12223 |
Indian Institute of Technology Chennai
| 6102432
| IS 5101 (1991) |
Twist drills, parallel shank, jobber. series - Specification (First Revision) |
- |
- View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
No Record Found
|
|
- |
- (Lab of national repute and eminence, facilities of which are being utilized by BIS.) |
| 12224 |
National Metallurgical Laboratory Unit, Chennai
| 6107814
| IS 8500 (1991) |
Structural Steel - Microalloyed (Medium and High Strength Qualities) |
- |
- View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
No Record Found
|
|
- |
- (Lab of national repute and eminence, facilities of which are being utilized by BIS.) |
| 12225 |
Fluid Control Research Institute, Palakkad
| 6114324
| IS 13095 (2020) |
Butterfly Valves for General Purposes ( First Revision ) |
- |
10600 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 17.2(Body Test) |
- |
1500 |
|
- |
| 17.3(Seat Test) |
- |
1200 |
|
- |
| 17.4(Disc Strength Test) |
- |
6400 |
|
- |
| 7(NOMINAL PRESSURES) |
- |
1500 |
|
Leakage Test |
|
06 Dec, 2028 |
- - |
| 12226 |
National Metallurgical Laboratory Unit, Chennai
| 6107814
| IS 21 (1992) |
Wrought aluminium and aluminium alloys for manufacture of utensils specification (Fourth Revision) |
- |
- View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
No Record Found
|
|
- |
- (Lab of national repute and eminence, facilities of which are being utilized by BIS.) |
| 12227 |
MSME Testing Centre, New Delhi
| 8101204
| IS 204 : Part 2 (1992) |
Tower bolts - Specification: Part 2 non - Ferrous metals (Fifth Revision) |
- |
4800 View breakup
Rs.4800/- (10% concession for BIS)
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 6.1- Table 1(Dimension of Barrel tower bolts-1.Size 2.Length of Bolt or Barrel-(A or B) 4.Width of Barrel-C 5.Dia of Bolt-D 6.Length of Socket-E 7.Thickness of Metal of Barrel (Brass or Zink Alloy/Aluminium alloy/Sheet Brass)-F 8.Dia of bore of barrel or socket- G ) |
- |
4500 |
|
- |
| 5.1(General) |
- |
300 |
|
- |
| 5.2.1 Table 1(Particulars-Barrel Tower Bolts) |
- |
300 |
|
- |
| 5.2.2 Table 2(Particulars-Skeleton Tower Bolts) |
- |
300 |
|
- |
| 6.1- Table 1(Dimension of barrel tower bolts-Minimum No. of equally Spaced holes in Barrel & Socket for wooden screw no 6) |
- |
300 |
|
- |
| 6.2- Table 2(Dimension of Skeleton Tower Bolts 1.Size 2.Length of Bolt -A 3.Length of Bolt Plate -B 4.Width of Bolt Plate or Staple-C 5.Dia of Bolt-D 6.Length of Staple-E 7.Thickness of Plate or Socket (Brass /Aluminium alloy or Zink Alloy)-F 8.Dia of bore of Plate or Staple-G 9.Dia of shank of Knob ) |
- |
300 |
|
- |
| 6.2- Table 2(Dimension of Skeleton Tower Bolts- Nos of Staples) |
- |
300 |
|
- |
| 6.2- Table 2(Dimension of Skeleton Tower Bolts-Minimum No. of Screw holes for wood screw no 4) |
- |
300 |
|
- |
| 6.2- Table 3(PACKING) |
- |
300 |
|
- |
|
31 Dec, 2026 |
- - |
| 12228 |
MSME Testing Centre, New Delhi
| 8101204
| IS 205 (1992) |
Non - Ferrous metal butt specification (Fourth Revision) |
- |
4500 View breakup
Rs.4500/- (10% concession for BIS)
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 5.1- Table 2,3,4,5 & Fig-1 & 2(Dimensions- Type of Hinge 1.Length 2.Breadth 3.Butt Dia 4.Pin Dia 5.Thickness of Flap) |
- |
2400 |
|
- |
| 5.1- Table 2,3,4,5 & Fig-1 & 2(Dimensions- 1. Holes for Screw Desination 2. No. of screw Holes) |
- |
600 |
|
- |
| 6.1(Manufacture- General) |
- |
300 |
|
- |
| 6.2- Table 2,3,4,5 (Kunckles) |
- |
300 |
|
- |
| 6.3.1- Table 2,3,4,5 & Fig-1 & 2(Screw Holes) |
- |
300 |
|
- |
| 6.3.2- Table 2,3,4,5 (Number of Holes) |
- |
300 |
|
- |
| 6.3.3 Fig-1(Position of Holes) |
- |
300 |
|
- |
| 8.1(Packing - Each hinge shall be packed in card board boxes or in any other approved packing. The number of hinges in a package shall be as under) |
- |
300 |
|
- |
|
31 Dec, 2026 |
- - |
| 12229 |
MSME Testing Centre, New Delhi
| 8101204
| IS 285 (1992) |
Laundry soaps - Specification (Third Revision) |
- |
13650 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 5.4, Table-1 (ix) Type-2 (Built soap) Gr-2(LSD/NSD content, IS 4955) |
- |
1050 |
|
- |
| 5.4, Table-1 (viii) Type-2 (Built soap) Gr-1 & Gr-2(Chloride (as sodium chloride), IS 286) |
- |
950 |
|
- |
| 5.4, Table-1 (viii) Type-1 (Pure soap)(Chloride (as sodium chloride), IS 286) |
- |
950 |
|
- |
| 5.4, Table-1 (vii) Type-1 (Pure soap)(Glycerol, IS 286) |
- |
1050 |
|
- |
| 5.4, Table-1 (vi) Type-1 (Pure soap)(Titre of total fatty acids, IS 286) |
- |
1350 |
|
- |
| 5.4, Table-1 (v) Type-2 (Built soap) Gr-1(Matter insoluble in alcohol, IS 286) |
- |
1050 |
|
- |
| 5.4, Table-1 (iv) (Free caustic alkali, as sodium hydroxide (NaOH), IS 286) |
- |
950 |
|
- |
| 5.4, Table-1 (iii) (Unsaponified fatty matter, IS 286) |
- |
1050 |
|
- |
| 5.4, Table-1 (ii) (Rosin acids, percent by mass of total fatty matter, IS 286 ) |
- |
1050 |
|
- |
| 5.4, Table-1 (i) Type-2 (Built soap) Gr-2(Total fatty matter, IS 286) |
- |
1350 |
|
- |
| 5.3(Odour and Lathering Properties, IS 286) |
- |
500 |
|
- |
| 5.1.1(Phenolic substances, IS 286) |
- |
950 |
|
- |
|
31 Dec, 2026 |
- - |
| 12230 |
Bharat Test House Pvt Ltd 1474 Sonipat Haryana
| 9135626
| IS 302 : Part 2 : Sec 202 (1992) |
Safety of household and similar electrical appliances: Part 2 particular requirements: Sec 202 electric stoves |
Electric stoves |
2275 View breakup
Rs.2275/-
(5% discount for
BIS)
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 6(Classification- IS 302-1 ) |
- |
0 |
|
- |
| 7.1(Marking- IS 302-1) |
- |
5 |
|
5% discount for BIS |
| 7.3(Marking- IS 302-1) |
- |
5 |
|
5% discount for BIS |
| 7.4(Marking- IS 302-1) |
- |
5 |
|
5% discount for BIS |
| 7.6(Marking- IS 302-1) |
- |
5 |
|
5% discount for BIS |
| 7.11(Marking- IS 302-1) |
- |
5 |
|
5% discount for BIS |
| 7.12(Marking- IS 302-1) |
- |
5 |
|
5% discount for BIS |
| 7.13(Marking- IS 302-1) |
- |
5 |
|
5% discount for BIS |
| 7.14(Marking- IS 302-1) |
- |
5 |
|
5% discount for BIS |
| 7.15(Marking- IS 302-1) |
- |
5 |
|
5% discount for BIS |
| 7.101(Marking) |
- |
5 |
|
5% discount for BIS |
| 8( Protection Against Electric Shock, IS 302-1) |
- |
150 |
|
5% discount for BIS |
| 10(Power Input and Current, IS 302-1) |
- |
100 |
|
5% discount for BIS |
| 11(Heating, IS 302-1) |
- |
250 |
|
5% discount for BIS |
| 13(Electrical Insulation and Leakage Current at Operating Temperature: Leakage current, IS 302-1) |
- |
100 |
|
5% discount for BIS |
| 15.1(Moisture Resistance, IS 302-1) |
- |
125 |
|
5% discount for BIS |
| 15.3(Moisture Resistance, IS 302-1) |
- |
125 |
|
5% discount for BIS |
| 16(Electrical Insulation and Leakage Current at Operating Temperature: Leakage current, IS 302-1) |
- |
50 |
|
5% discount for BIS |
| 16(Electrical Insulation and Leakage Current at Operating Temperature: High Voltage, IS 302-1) |
- |
50 |
|
5% discount for BIS |
| 19.2(Abnormal Operation, IS 302-1) |
- |
125 |
|
5% discount for BIS |
| 19.3(Abnormal Operation, IS 302-1) |
- |
125 |
|
5% discount for BIS |
| 20.1(Stability & Mechanical Hazards, IS 302-1) |
- |
150 |
|
5% discount for BIS |
| 21.1(Mechanical Strength, IS 302-1 & IS 302-2-202) |
- |
50 |
|
5% discount for BIS |
| 22(Construction, IS 302-1) |
- |
6 |
|
5% discount for BIS |
| 22.101(Construction) |
- |
6 |
|
5% discount for BIS |
| 22.102(Construction) |
- |
6 |
|
5% discount for BIS |
| 22.103(Construction) |
- |
6 |
|
5% discount for BIS |
| 22.104(Construction) |
- |
6 |
|
5% discount for BIS |
| 22.105(Construction) |
- |
6 |
|
5% discount for BIS |
| 22.106(Construction) |
- |
6 |
|
5% discount for BIS |
| 22.107(Construction) |
- |
6 |
|
5% discount for BIS |
| 23.1(Internal Wiring, IS 302-1) |
- |
10 |
|
5% discount for BIS |
| 23.2(Internal Wiring, IS 302-1) |
- |
10 |
|
5% discount for BIS |
| 23.8(Internal Wiring, IS 302-1) |
- |
10 |
|
5% discount for BIS |
| 23.9(Internal Wiring, IS 302-1) |
- |
10 |
|
5% discount for BIS |
| 23.10(Internal Wiring, IS 302-1) |
- |
10 |
|
5% discount for BIS |
| 25.1(Supply Connection and External Flexible Cords, IS 302-1) |
- |
25 |
|
5% discount for BIS |
| 25.2(Supply Connection and External Flexible Cords, IS 302-1) |
- |
25 |
|
5% discount for BIS |
| 26(Terminals for External Conductors, IS 302-1) |
- |
50 |
|
5% discount for BIS |
| 27.1(Provision for Earthing, IS 302-1) |
- |
10 |
|
5% discount for BIS |
| 27.2(Provision for Earthing, IS 302-1) |
- |
10 |
|
5% discount for BIS |
| 27.3(Provision for Earthing, IS 302-1) |
- |
10 |
|
5% discount for BIS |
| 27.4(Provision for Earthing, IS 302-1) |
- |
10 |
|
5% discount for BIS |
| 27.5(Provision for Earthing, IS 302-1) |
- |
10 |
|
5% discount for BIS |
| 28(Screws & Connections, IS 302-1) |
- |
50 |
|
5% discount for BIS |
| 29.1(Clearances, Creepage distances and Solid Insulation, IS 302-1) |
- |
25 |
|
5% discount for BIS |
| 29.2(Clearances, Creepage distances and Solid Insulation, IS 302-1) |
- |
25 |
|
5% discount for BIS |
| 30.1(Resistance to Heat, Fire & Tracking, IS 302-1) |
- |
88 |
|
5% discount for BIS |
| 30.2(Resistance to Heat, Fire & Tracking, IS 302-1) |
- |
88 |
|
5% discount for BIS |
| 31(Resistance of Rusting, IS 302-1) |
- |
100 |
|
5% discount for BIS |
|
19 Mar, 2026 |
- Exclusion: 22.16 SPECIAL TEST (Automatic cord reel), 22.32 SPECIAL TEST (TEST ON CERAMIC MATERIAL), 22.46 SPECIAL TEST (SOFTWARE), 24.1 (Components) |
| 12231 |
Central Power Research Institute (CPRI), Bangalore
| 6101024
| IS 398 : Part 5 (1992) |
Aluminium conductor for overhead transmission purposes - Specification: Part 5 aluminium conductors - Galvanized steel - Reinforced for extra high voltage (400 KV And Above) (First Revision) |
- |
85000 View breakup
Nominal Al area 500mm2 to 690mm2 – Rs. 1,82,680/-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 13.2 (mech)(Visual Examination) |
- |
850 |
|
PER CONDUCTOR |
| 13.3 Table-1 (mech)(Diameter-Aluminium wires) |
- |
850 |
|
PER CONDUCTOR |
| 13.5.1 Table 3 (elec)(Breaking Load on Complete conductor) |
- |
3100 |
|
PER WIRE / LAYER |
| 13.3 Table-2 (mech)(Diameter-Galvanized Steel wires) |
- |
850 |
|
PER CONDUCTOR |
| 13.5.2 Table 1 (mech)(Breaking Load of Aluminium Wires Before Stranding) |
- |
3100 |
|
PER WIRE / LAYER |
| 13.5.2 Table 2 (mech)(Breaking Load of Steel Wires Before Stranding) |
- |
3100 |
|
PER WIRE / LAYER |
| 13.6.1 (mech)(Ductility by Torsion Test before stranding) |
- |
2300 |
|
PER WIRE / LAYER |
|
31 Dec, 2026 |
- - |
| 12232 |
National Metallurgical Laboratory Unit, Chennai
| 6107814
| IS 739 (1992) |
Wrought aluminium and aluminium alloys - Wire for general engineering purposes - Specification (Third Revision) |
- |
- View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
No Record Found
|
|
- |
- (Lab of national repute and eminence, facilities of which are being utilized by BIS.) |
| 12233 |
MSME Testing Centre, New Delhi
| 8101204
| IS 1746 (1992) |
Shoe polish, paste - Specification (Third Revision) |
- |
13050 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4.1.1(Odour) |
- |
850 |
|
- |
| 4.1.2(Colour) |
- |
850 |
|
- |
| 4.1.3(Consistency) |
- |
850 |
|
- |
| 4.1.4(Applicability) |
- |
850 |
|
- |
| 4.1.6(colour of water extract) |
- |
850 |
|
- |
| 4.2 (table 1 S.no(i))(Softeing point of non-volatile matter) |
- |
850 |
|
- |
| 4.2 (table 1 S.no(ii))(Ash of the non-volatile matter) |
- |
850 |
|
- |
| 4.2 (table 1 S.no(iii))(pH of water extract
) |
- |
850 |
|
- |
| 4.2 (table 1 S.no(iv))(Distillation range of
volatile portion
) |
- |
850 |
|
- |
| 4.2 (table 1 S.no(v))(Flash point of volatile portion,) |
- |
850 |
|
- |
| 4.2 (table 1 S.no(vi))(Non-volatile matter
) |
- |
850 |
|
- |
|
31 Dec, 2026 |
- - |
| 12234 |
MSME Testing Centre, New Delhi
| 8101204
| IS 2074 (2015) |
Ready mixed paint, air drying, red oxide - Zinc chrome, priming - Specification (Third Revision) |
- |
9500 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl 5.1 (a)(Composition, Pigment, Cl 5.1.1) |
- |
500 |
|
- |
| Cl 5.1 (b)(Composition, Driers) |
- |
500 |
|
- |
| Cl 5.1 .1 (a)(Zinc chrome, (Type 2 of
IS 51), Annex B) |
- |
500 |
|
- |
| Cl 5.1 .1 (b)(Synthetic red oxides of iron (conforming to Grade 2 or
IS 44), (conforming to Grade 3
of IS 44), 6 of IS 6947
(Part 2)) |
- |
500 |
|
- |
| Cl 5.1 .1 (c)(Suitable extenders) |
- |
500 |
|
- |
| Cl 5.1.2(Volatile vehicle) |
- |
500 |
|
- |
| Cl 5.2(Material) |
- |
500 |
|
- |
| Cl 5.3(Compatibility with Thinner, IS 1872) |
- |
500 |
|
- |
| Cl 5.4(Freedom from Objectionable Impurities) |
- |
500 |
|
- |
| Cl 5.5(Lead Restriction, IS 101(Part 8/Sec 5)) |
- |
1000 |
|
- |
| 1 (i) (a) Table 1(Consistency, Annex C) |
- |
500 |
|
- |
| 1 (i) (b) Table 1(Viscosity by ford cup No. 4, IS 101 (Part1/sec5)) |
- |
500 |
|
- |
| 1 (ii) Table 1(Mass, IS 101 (Part1/sec7)) |
- |
500 |
|
- |
| 1 (iii) (a) Table 1(Drying time, Surface Dry, IS 101 (Part3/sec1)) |
- |
500 |
|
- |
| 1 (iii) (b) Table 1(Drying time, Hard Dry, IS 101 (Part3/sec1)) |
- |
500 |
|
- |
| 1 (iv) (a) Table 1(Finish, IS 101 (Part3/sec4)) |
- |
500 |
|
- |
| 1 (iv) (b) Table 1(Gloss, IS 101 (Part4/sec4)) |
- |
500 |
|
- |
| 1 (v) Table 1(Fineness of grind, IS 101 (Part 3/Sec 5)) |
- |
500 |
|
- |
| 1 (vi) Table 1(Colour, IS 101 (Part 4/Sec 2)) |
- |
500 |
|
- |
| 1 (vii) (a) Table 1(Flexibility and adhesion: Bend test (with 6.25 mm dia mandrel and in type 1 apparatus), Clause 2 of IS 101 (Part 5/Sec 2)) |
- |
800 |
|
- |
| 1 (vii) (b) Table 1(Scratch hardness (load 1 000g), Clause 3 of IS 101 (Part 5/Sec 2)) |
- |
500 |
|
- |
| 1 (viii) Table 1(Flash point, IS 101 (Part l/Sec 6)) |
- |
500 |
|
- |
| 1 (ix) Table 1(Volume solids, IS 101 (Part 8/Sec 6)) |
- |
800 |
|
- |
| 1 (x) (a) Table 1(Resistance to humidity under condition of condensation: Resistance to humidity, Clause 2 of IS 101 (Part 6/Sec 1)) |
- |
2000 |
|
- |
| 1 (x) (b) Table 1(Resistance to humidity under condition of condensation: Resistance to sea water (applicable for marine paints only), Annex D) |
- |
2000 |
|
- |
| 1 (x) (c) Table 1(Resistance to humidity under condition of condensation: Resistance to salt spray, Annex E) |
- |
2000 |
|
- |
| 1 (xi) Table 1(Accelerated storage stability test, Annex F) |
- |
2000 |
|
- |
|
31 Dec, 2026 |
- - |
| 12235 |
MSME Testing Centre, New Delhi
| 8101204
| IS 5487 (1992) |
Metal polish, liquid - Specification (First Revision) |
- |
14700 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4.8, Table-1 (vi) (Oleic acid content, IS 5487 ) |
- |
1500 |
|
- |
| 4.8, Table-1 (v) (Flash point (Abel), IS 1448 Part-20) |
- |
1000 |
|
- |
| 4.8, Table-1 (iv) (Cyanides, IS 5487) |
- |
1000 |
|
- |
| 4.8, Table-1 (iii) (Residue on 75miron IS Sieve, IS 5487) |
- |
1000 |
|
- |
| 4.8, Table-1 (ii) (Total ammonia (as NH3), IS 5487) |
- |
1000 |
|
- |
| 4.8, Table-1 (i) (Total solids (excluding oils and fatty matter), IS 5487) |
- |
1000 |
|
- |
| 4.7(Keeping Quality, IS 5487) |
- |
7000 |
|
- |
| 4.6(Acidity of the Aqueous Extract, IS 5487) |
- |
500 |
|
- |
| 4.5(Polishing Property, IS 5487) |
- |
500 |
|
- |
| 4.4(Stability, IS 5487) |
- |
500 |
|
- |
| 4.3(Consistency, IS 5487 ) |
- |
500 |
|
- |
|
31 Dec, 2026 |
- - |
| 12236 |
MSME Testing Centre, New Delhi
| 8101204
| IS 8978 (1992) |
Specification for electric instantaneous water heaters (Second Revision) |
0 |
15000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl.8 of IS 302-2-35:2017(Protection Against Access To Live Parts) |
- |
2500 |
|
- |
| Cl.10 of IS 302-2- 35:2011(Power Input & Current ) |
- |
2500 |
|
- |
| Cl.11 of 302-2-35:2017(Heating : Temperature rise of test corner) |
- |
3000 |
|
- |
| Cl.13 of IS 302-2-35:2017(Leakage Current & Electrical Strength at Operating Temperature ) |
- |
4000 |
|
- |
| Cl.14 of IS 302-2-35:2017(Transient Over Voltages ) |
- |
2000 |
|
- |
| Cl.15 of IS 302-2-35-2011(Moisture Resistance ) |
- |
4000 |
|
- |
| Cl.16 of IS 302-2-Â35:2017(Leakage Current and Electric Strength (After Humidity)) |
- |
4000 |
|
- |
| Cl.19 of IS 302-2-35:2017(Abnormal Operation) |
- |
4000 |
|
- |
| Cl 22.26 ,Cl.22.28, Cl 22.29, Cl 22.30 , Cl 22.31, Cl 22.32 of
IS 302-1:2008(Construction : Supplymentry/ double / reinforced insulation for Class II/ Class III appliance ) |
- |
2000 |
|
- |
| Cl.26 of IS 302-2-35:2017(Terminals for External Conductors) |
- |
2000 |
|
- |
| Cl.27 of IS 302-2-35:2017(Provision for Earthing) |
- |
2000 |
|
- |
| Cl.28 of IS 302-2-35:2017(Screws and Connections
) |
- |
2000 |
|
- |
| Cl.30.1 of IS 302-1:2008(Resistance to Heat and Fire) |
- |
4000 |
|
- |
| Cl.31 of IS 302-2-35: 2011(Resistance to Rusting
) |
- |
2500 |
|
- |
| Cl.25 of IS 302-2-35:2017(Supply Connection & External Flexible Cords) |
- |
2500 |
|
- |
| Cl.29 of IS 302-2-35:2017(Clearances, Creepage Distances and Solid Insulation) |
- |
2500 |
|
- |
| Cl.12 of IS 8978 : 1992(Endurance) |
- |
4000 |
|
- |
|
31 Dec, 2026 |
- Excl: Cl.19.11.4.1 to Cl.19.11.4.7 (EMI/EMC Test) |
| 12237 |
Central Power Research Institute (CPRI), Bangalore
| 6101024
| IS 13314 (1992) |
Solid state inverters run from storage batteries - Specification |
SOLID STATE INVERTERS |
157000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4(General requirements) |
- |
0 |
|
The complete test charges will be intimated at the time of issuing the proforma invoice. |
| 5(Technical requirements) |
- |
0 |
|
The complete test charges will be intimated at the time of issuing the proforma invoice. |
| 6(Marking) |
- |
0 |
|
The complete test charges will be intimated at the time of issuing the proforma invoice. |
| 7(Tests and performance requirements) |
- |
0 |
|
The complete test charges will be intimated at the time of issuing the proforma invoice. |
| 7.2(Type tests) |
- |
0 |
|
The complete test charges will be intimated at the time of issuing the proforma invoice. |
| 8(Packing) |
- |
0 |
|
The complete test charges will be intimated at the time of issuing the proforma invoice. |
| 9(Information to be supplied by the supplier) |
- |
0 |
|
The complete test charges will be intimated at the time of issuing the proforma invoice. |
|
31 Dec, 2026 |
- ISS included w.e.f. 23/7/2018 |
| 12238 |
CENTRAL INSTITUTE OF PETROCHEMICALS ENGINEERING AND TECHNOLOGY (CIPET):CSTS-BHOPAL
| 8100534
| IS 13410 (1992) |
Glass reinforced polyester sheet moulding compounds(Smc) - Specification |
- |
- View breakup
Rs.24825/-
(After 25% discount for BIS)
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
No Record Found
|
|
31 Dec, 2026 |
- For S1 & S2 grade only |
| 12239 |
Central Power Research Institute (CPRI), Bangalore
| 6101024
| IS 7098 : Part 3 (1993) |
Cross - Linked polyethylene insulated thermoplastic sheathed cables - Specification: Part 3 for working voltages from 66 kV up to and including 220 kV |
- |
3922000 View breakup
Type Test on single core XLPE Insulated PVC/PE Sheathed Cable of Voltage rating 66 kV with conductor cross sections up to and including 1000 sq.mm Rs. 775920 /- + 18 % GST
Type test on single core XLPE Insulated PVC/PE Sheathed cable of Voltage rating 66 kV with conductor cross sections above 1000 sq.mm up to and including 1600 sq.mm Rs 820680+ 18 % GST
Type test on Single core XLPE Insulated PVC/PE Sheathed cable of voltage rating 66 kV with conductor cross sections above 1600 sq.mm up to and including 2500 sq.mm Rs.946210 + 18 % GST
Type test on 3 Core XLPE Insulated PVC/PE Sheathed cable of voltage rating 66 kV rating Rs. 1005010 + 18 % GST Type test on XLPE Insulated PVC/PE Sheathed cable of Voltage rating 132 kV with conductor cross sections up and including 1000 sq.mm Rs.1687880 + 18 % GST
Type test on XLPE Insulated cable of voltage rating 132 kV with conductor cross sections above 1000 sq.mm up to and including 1600 sq.mm Rs. 1887920+ 18 % GST
Type test on XLPE Insulated cable of voltage rating 132 kV with conductor cross sections above 1600 Sq.mm Rs.2276000 + 18 % GST Type Test on XLPE Insulated PE/PVC Sheathed cable of voltage rating 220 kV with conductor cross section up to and including 1000 sq.mm Rs.2899640 /- + 18 % GST
Type test on XLPE Insulated PVC/PE Sheathed cable voltage rating 220 kV with conductor cross sections above 1000 sq.mm up to and including 1600 sq.mm, Rs. 3877180 /- 18 % GST
Type test on XLPE Insulated PVC/PE Sheathed cable voltage rating 220 kV conductor cross sections above 1600 sq.mm up to and including 2500 sq.mm, Rs. 4331790 /- + 18 % GST
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4.1(CONDUCTOR) |
- |
0 |
|
The complete test charges applicable will be intimated through proforma invoice. |
| 5(INSULATION) |
- |
0 |
|
The complete test charges applicable will be intimated through proforma invoice. |
| 6(SCREENING) |
- |
0 |
|
The complete test charges applicable will be intimated through proforma invoice. |
| 7.1(MOISTURE BARRIER : Laminated Tape) |
- |
0 |
|
The complete test charges applicable will be intimated through proforma invoice. |
| 7.2(MOISTURE BARRIER : Lead Alloy Sheath) |
- |
0 |
|
The complete test charges applicable will be intimated through proforma invoice. |
| 7.3(MOISTURE BARRIER : Water Blocking Tape/Powder) |
- |
0 |
|
The complete test charges applicable will be intimated through proforma invoice. |
| 8.1(INNER SHEATH) |
- |
0 |
|
The complete test charges applicable will be intimated through proforma invoice. |
| 8.2(INNER SHEATH) |
- |
0 |
|
The complete test charges applicable will be intimated through proforma invoice. |
| 8.3(INNER SHEATH) |
- |
0 |
|
The complete test charges applicable will be intimated through proforma invoice. |
| 9.1(ARMOUR) |
- |
0 |
|
The complete test charges applicable will be intimated through proforma invoice. |
| 9.2(ARMOUR) |
- |
0 |
|
The complete test charges applicable will be intimated through proforma invoice. |
| 10.1(OUTER SHEATH) |
- |
0 |
|
The complete test charges applicable will be intimated through proforma invoice. |
| 10.2(OUTER SHEATH) |
- |
0 |
|
The complete test charges applicable will be intimated through proforma invoice. |
| 11.1(CONDUCTOR) |
- |
0 |
|
The complete test charges applicable will be intimated through proforma invoice. |
| 11.2(CONDUCTOR) |
- |
0 |
|
The complete test charges applicable will be intimated through proforma invoice. |
| 12.1(CONDUCTOR SCREENING ) |
- |
0 |
|
The complete test charges applicable will be intimated through proforma invoice. |
| 12.2(CONDUCTOR SCREENING ) |
- |
0 |
|
The complete test charges applicable will be intimated through proforma invoice. |
| 13.1(INSULATION) |
- |
0 |
|
The complete test charges applicable will be intimated through proforma invoice. |
| 13.2(INSULATION) |
- |
0 |
|
The complete test charges applicable will be intimated through proforma invoice. |
| 14.1(INSULATION SCREENING) |
- |
0 |
|
The complete test charges applicable will be intimated through proforma invoice. |
| 14.2.1(INSULATION SCREENING : Non-metallic Part) |
- |
0 |
|
The complete test charges applicable will be intimated through proforma invoice. |
| 14.2.2(INSULATION SCREENING : Non-metallic Part) |
- |
0 |
|
The complete test charges applicable will be intimated through proforma invoice. |
| 14.2.3(INSULATION SCREENING : Non-metallic Part) |
- |
0 |
|
The complete test charges applicable will be intimated through proforma invoice. |
| 14.3.1(INSULATION SCREENING : Metallic Part) |
- |
0 |
|
The complete test charges applicable will be intimated through proforma invoice. |
| 14.3.2(INSULATION SCREENING : Metallic Part) |
- |
0 |
|
The complete test charges applicable will be intimated through proforma invoice. |
| 14.3.3(INSULATION SCREENING : Metallic Part) |
- |
0 |
|
The complete test charges applicable will be intimated through proforma invoice. |
| 15.1(MOISTURE BARRIER) |
- |
0 |
|
The complete test charges applicable will be intimated through proforma invoice. |
| 15.2.1(Metallic Sheath) |
- |
0 |
|
The complete test charges applicable will be intimated through proforma invoice. |
| 15.2.2(Metallic Sheath) |
- |
0 |
|
The complete test charges applicable will be intimated through proforma invoice. |
| 16.1(INNER SHEATH) |
- |
0 |
|
The complete test charges applicable will be intimated through proforma invoice. |
| 16.2(INNER SHEATH) |
- |
0 |
|
The complete test charges applicable will be intimated through proforma invoice. |
| 17.1(ARMOUR) |
- |
0 |
|
The complete test charges applicable will be intimated through proforma invoice. |
| 17.2(ARMOUR) |
- |
0 |
|
The complete test charges applicable will be intimated through proforma invoice. |
| 17.3(ARMOUR) |
- |
0 |
|
The complete test charges applicable will be intimated through proforma invoice. |
| 17.4(ARMOUR) |
- |
0 |
|
The complete test charges applicable will be intimated through proforma invoice. |
| 17.5(ARMOUR) |
- |
0 |
|
The complete test charges applicable will be intimated through proforma invoice. |
| 18.1(OUTER SHEATH) |
- |
0 |
|
The complete test charges applicable will be intimated through proforma invoice. |
| 18.2(outer sheath colour) |
- |
0 |
|
The complete test charges applicable will be intimated through proforma invoice. |
| 18.3.1(Thickness of Outer Sheath : Unarmoured Cables) |
- |
2300 |
|
The complete test charges applicable will be intimated through proforma invoice. |
| 18.3.1(Thickness of Outer Sheath : armoured Cables) |
- |
2300 |
|
The complete test charges applicable will be intimated through proforma invoice. |
| 19.1 A) I)(Tests on conductor : Annealing test ( for copper )) |
- |
1450 |
|
The test charges is applicable for one core and if the number core increases, test charges will also increase proportionally.
The complete test charges applicable will be intimated through proforma invoice. |
| 19.1 A) II)(Tests on conductor : Resistance test) |
- |
2300 |
|
The test charges is applicable for one core and if the number core increases, test charges will also increase proportionally.
The complete test charges applicable will be intimated through proforma invoice. |
| 19.1 b) I)(Test for thickness and dimensions of insulation) |
- |
2300 |
|
The test charges is applicable for one core and if the number core increases, test charges will also increase proportionally.
The complete test charges applicable will be intimated through proforma invoice. |
| 19.1 b) II)(Tensile strength and elongation at break) |
- |
6200 |
|
The test charges is applicable for one core and if the number core increases, test charges will also increase proportionally.
The complete test charges applicable will be intimated through proforma invoice. |
| 19.1 b) III)(Thermal ageing in air oven) |
- |
5300 |
|
The complete test charges applicable will be intimated through proforma invoice. |
| 19.1 b) IV)(Hot set test) |
- |
2300 |
|
The test charges is applicable for one core and if the number core increases, test charges will also increase proportionally.
The complete test charges applicable will be intimated through proforma invoice. |
| 19.1 b) V)(Shrinkage test) |
- |
1000 |
|
The test charges is applicable for one core and if the number core increases, test charges will also increase proportionally.
The complete test charges applicable will be intimated through proforma invoice. |
| 20.3(Test for concentric metallic screen : Test for concentric copper wire) |
- |
4600 |
|
The complete test charges applicable will be intimated through proforma invoice. |
| 20.4(Test for concentric copper tape) |
- |
4600 |
|
The complete test charges applicable will be intimated through proforma invoice. |
| 20.5(Thickness of metallic sheath) |
- |
2300 |
|
The complete test charges applicable will be intimated through proforma invoice. |
| 20.6(Tests for armouring material : Dimensions) |
- |
2300 |
|
The complete test charges applicable will be intimated through proforma invoice. |
| 19.1 f) II)(Tests for armouring material : Tensile strength and elongation at break) |
- |
5300 |
|
The complete test charges applicable will be intimated through proforma invoice. |
| Table 9, (Measurement of thickness) |
- |
2300 |
|
The test charges is applicable for one core and if the number core increases, test charges will also increase proportionally.
The complete test charges applicable will be intimated through proforma invoice. |
| 19.1 g)2) i)(PVC sheath : Tensile strength and elongation at break) |
- |
6200 |
|
The complete test charges applicable will be intimated through proforma invoice. |
| 19.1 g)2) iii)(PVC sheath : Loss of mass) |
- |
5300 |
|
The complete test charges applicable will be intimated through proforma invoice. |
| 19.1 g)2) v)(PVC sheath : Hot deformation test) |
- |
2200 |
|
The complete test charges applicable will be intimated through proforma invoice. |
| 19.1 g)2) vi)(PVC sheath : Shrinkage test) |
- |
1000 |
|
The complete test charges applicable will be intimated through proforma invoice. |
| 19.1 g)2) vii)(PVC sheath : Thermal stability) |
- |
3000 |
|
The complete test charges applicable will be intimated through proforma invoice. |
| 19.1 g)3) ii)(PE sheath : Tensile strength and elongation at break before and after ageing) |
- |
6200 |
|
The complete test charges applicable will be intimated through proforma invoice. |
| 19.1 g)3) iii)(PE sheath : Hot-detormation) |
- |
2200 |
|
The complete test charges applicable will be intimated through proforma invoice. |
| 20.7(Flammabihty test ( for PVC outer
sheathed cables only )) |
- |
1600 |
|
The complete test charges applicable will be intimated through proforma invoice. |
| 20.8.3(Water tightness test) |
- |
4400 |
|
The complete test charges applicable will be intimated through proforma invoice. |
| 20.9.1(Thermal ageing on complete cable sample) |
- |
5300 |
|
The complete test charges applicable will be intimated through proforma invoice. |
| 19.1 k) ii)(Tensile strength and elongation at breakfor insulation and outer sheath) |
- |
6200 |
|
The test charges is applicable for one core and if the number core increases, test charges will also increase proportionally.
The complete test charges applicable will be intimated through proforma invoice. |
| 20.2(Resistivity test for semi-conducting layer) |
- |
2300 |
|
The complete test charges applicable will be intimated through proforma invoice. |
| 20.11.1(Bending test followed by P D test) |
- |
12750 |
|
The complete test charges applicable will be intimated through proforma invoice. |
| 20.12, 20.18(Dielectric power factor and capacitance measurement at ambient temperature) |
- |
6900 |
|
The test charges will change with respect to voltage rating, cross section and number of cores of the cable,
The complete test charges applicable will be intimated through proforma invoice. |
| 20.13(Dielectric power factor measurement at elevated temperature) |
- |
8350 |
|
The test charges will change with respect to voltage rating, cross section and number of cores of the cable,
The complete test charges applicable will be intimated through proforma invoice. |
| 20.14.1(Load cycle test followed by P.D measurement) |
- |
271050 |
|
The test charges will change with respect to voltage rating, cross section and number of cores of the cable,
The complete test charges applicable will be intimated through proforma invoice. |
| 20.15(Impulse Voltage Test Followed by High Voltage Test) |
- |
35850 |
|
The test charges will change with respect to voltage rating, cross section and number of cores of the cable,
The complete test charges applicable will be intimated through proforma invoice. |
| 19.5(Check on Insulation Thickness Before the Electrical Type Tests) |
- |
2300 |
|
The test charges is applicable for one core and if the number core increases, test charges will also increase proportionally.
The complete test charges applicable will be intimated through proforma invoice. |
| 20.16.1(Test for Dimensions of Insulation : Insulation Thickness) |
- |
2300 |
|
The test charges is applicable for one core and if the number core increases, test charges will also increase proportionally.
The complete test charges applicable will be intimated through proforma invoice. |
| 20.16.2(Test for Dimensions of Insulation : Test for Eccentricity) |
- |
2300 |
|
The test charges is applicable for one core and if the number core increases, test charges will also increase proportionally.
The complete test charges applicable will be intimated through proforma invoice. |
| 20.16.3(Test for Dimensions of Insulation : Test for Ovality) |
- |
2300 |
|
The test charges is applicable for one core and if the number core increases, test charges will also increase proportionally.
The complete test charges applicable will be intimated through proforma invoice. |
| 20.17(High Voltage Test ( as Routine and
Acceptance Tests ) ) |
- |
35850 |
|
The test charges will change with respect to voltage rating, cross section and number of cores of the cable,
The complete test charges applicable will be intimated through proforma invoice. |
| 20.18(Measurement of Capacitance) |
- |
8350 |
|
The test charges will change with respect to voltage rating, cross section and number of cores of the cable,
The complete test charges applicable will be intimated through proforma invoice. |
| 15.4 (b)(Cold impact) |
- |
7600 |
|
The complete test charges applicable will be intimated through proforma invoice. |
|
31 Dec, 2026 |
- - |
| 12240 |
Central Power Research Institute (CPRI), Bangalore
| 6101024
| IS 13703 : Part 2 : Sec 1 (1993) |
Specification for low - Voltage fuses for voltages not exceeding 1000 v ac or1500vdc: Part 2 fuses for use by authorized persons Sec 1 supplementary requirements |
- |
- View breakup
Rs.70250/- upto 200 A;
Rs.76650/- upto 1000 A
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
No Record Found
|
|
31 Dec, 2026 |
- - |