| 1441 |
DYNAMIC TEST LABORATORIES LLP
| 9197626
| IS 302 : Part 2 : Sec 80 (2017) |
Household and similar electrical appliances - Safety: Part 2 - 80 particular requirements for fans (First Revision) |
ELECTRICAL |
9500 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 32.0(Radiation, Toxicity and Similar Hazards) |
- |
1000 |
|
- |
| 31.0(Resistance To Rusting) |
- |
1000 |
|
- |
| 30.0(Resistance To Heat and Fire) |
- |
1000 |
|
- |
| 29.0(Creepage Distances and Clearances) |
- |
1000 |
|
- |
| 28.0(Screws and Connections) |
- |
1000 |
|
- |
| 27.0(Provision For Earthing) |
- |
1000 |
|
- |
| 26.0(Terminals for external conductors) |
- |
1000 |
|
- |
| 25.0(Supply Connection and External Flexible Cords) |
- |
1000 |
|
- |
| 24.0(Components) |
- |
1000 |
|
- |
| 23.0(Internal Wiring) |
- |
1000 |
|
- |
| 22.0(Construction) |
- |
1000 |
|
- |
| 21.0(Mechanical Strength) |
- |
1000 |
|
- |
| 20.0(Stability and mechanical hazards) |
- |
1000 |
|
- |
| 19.0(Abnormal Operation) |
- |
1000 |
|
- |
| 17.0(Overload Protection of transformer and associated circuit) |
- |
1000 |
|
- |
| 16.0(Leakage current and Electric strength (After Humidity (Environmental) Treatment)) |
- |
1000 |
|
- |
| 15.0(Moisture resistance) |
- |
1000 |
|
- |
| 14.0(Transient Overvoltage) |
- |
1000 |
|
- |
| 13.0(Leakage Current and electric strength at operating temperature) |
- |
1000 |
|
- |
| 11.0(Heating) |
- |
1000 |
|
- |
| 10.0(Input and Current) |
- |
1000 |
|
- |
| 8.0(Protection against access to live parts) |
- |
1000 |
|
- |
| 7.0(Classification) |
- |
1000 |
|
- |
| 6.0(Marking and Instructions) |
- |
1000 |
|
- |
| 19.11.4.1(Electrostatic discharges) |
- |
1000 |
|
- |
| 19.11.4.2(Radiated fields) |
- |
1000 |
|
- |
| 19.11.4.3(Fast transient bursts) |
- |
1000 |
|
- |
| 19.11.4.4(Surge immunity test) |
- |
1000 |
|
- |
| 19.11.4.5(Immunity to conducted discharges) |
- |
1000 |
|
- |
| 19.11.4.6(Class 3 Voltage dips and interruptions) |
- |
1000 |
|
- |
| 19.11.4.7(Harmonics) |
- |
1000 |
|
- |
| 4(GENERAL REQUIREMENT) |
- |
1000 |
|
- |
| 5(GENERAL CONDITIONS FOR THE TESTS) |
- |
1000 |
|
- |
|
- |
- Exclusion: Cl.19.11.4.1 to Cl.19.11.4.7 (EMI/EMC) |
| 1442 |
ARYAVRAT TEST HOUSE PRIVATE LIMITED
| 5191706
| IS 1786 (2008) |
High strength deformed steel bars and wires for concretere inforcement - Specification (Fourth Revision) |
All grade : Excluding Cl 5.7 Pull Out test |
14000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl 9.4(Load In Other Direction From Bend) |
- |
1000 |
|
- |
| Cl 9.3(Load In One Direction) |
- |
1000 |
|
- |
| Cl 7.2(Weight) |
- |
500 |
|
- |
| Cl 6.1(Length, Width & Thickness) |
- |
500 |
|
- |
| Cl 9.4(Load In Other Direction From Bend) |
- |
1000 |
|
- |
| Cl 6.1(Length, Width & Thickness) |
- |
500 |
|
- |
| Cl 5(Deformations and Surface Characteristics) |
- |
500 |
|
- |
| Cl 9.4(Load In Other Direction From Bend) |
- |
1000 |
|
- |
| Cl 9.3(Load In One Direction) |
- |
500 |
|
- |
| Cl 7.2(Weight) |
- |
500 |
|
- |
| Cl 9.3(Load In One Direction) |
- |
500 |
|
- |
| Cl 8.1(UTM) |
- |
1500 |
|
- |
| Cl 7.2(Weight) |
- |
500 |
|
- |
| Cl 6.1(Length, Width & Thickness) |
- |
500 |
|
- |
| Cl 5(Deformations and Surface Characteristics) |
- |
500 |
|
- |
| Clause - 4.2 & 4.2.1(Fe- 415, Fe- 415D, Fe-500, Fe-500D, Fe-550, Fe-550D, Fe-600 CARBON +EQUIVELENT ) |
- |
1000 |
|
- |
| 4.1(Sulphur and phosphorous) |
- |
1000 |
|
- |
| 4.1(CE) |
- |
1000 |
|
- |
| 4.1( Nitrogen%) |
- |
1000 |
|
- |
| 4.1(Ni) |
- |
500 |
|
- |
| 4.1(Mo) |
- |
500 |
|
- |
| 4.1(Cr) |
- |
500 |
|
- |
| 4.1( Ti) |
- |
500 |
|
- |
| 4.1(V) |
- |
500 |
|
- |
| 4.1( Nb) |
- |
500 |
|
- |
| 4.1( Aluminium %) |
- |
500 |
|
- |
| 4.1( Copper %) |
- |
500 |
|
- |
| 4.1(Silicon %) |
- |
500 |
|
- |
| 4.1(Sulphur %) |
- |
500 |
|
- |
| 4.1(Phosphorus %) |
- |
500 |
|
- |
| 4.1(Manganese %) |
- |
500 |
|
- |
| 4.1(Carbon %) |
- |
500 |
|
- |
| Cl.9.4 & Cl. 9.4.1(Rebend test) |
- |
500 |
|
- |
| Cl. 9.3, Table 4(Bend Test ) |
- |
500 |
|
- |
| Cl. 8.1 Table 3(Elongation, percentage) |
- |
500 |
|
- |
| Cl. 8.1 Table 3(TS/YS ratio) |
- |
500 |
|
- |
| Cl. 8.1 Table 3(Tensile Strength (TS)) |
- |
1000 |
|
- |
| Cl. 8.1 Table 3(Yield Stress (YS)) |
- |
1000 |
|
- |
| Cl. 7.2 Table -2 (Nominal Mass) |
- |
500 |
|
- |
| Cl. 6.1(Nominal Size) |
- |
500 |
|
- |
| Cl. 5 (Cl. 5 - Mean projected area of transverse ribs (1/3 of Ar)) |
- |
500 |
|
- |
| Cl. 5 (Cl.5 Mean area of ribs/unit length (Ar), ) |
- |
500 |
|
- |
| Clause - 4.2 & 4.2.1(Fe- 415, Fe- 415D, Fe-500, Fe-500D, Fe-550, Fe-550D, Fe-600 SULPHUR+PHOSPHUR) |
- |
500 |
|
- |
| Clause - 4.2 & 4.2.1(Fe- 415, Fe- 415D, Fe-500, Fe-500D, Fe-550, Fe-550D, Fe-600 MANGANESE) |
- |
500 |
|
- |
| Clause - 4.2 & 4.2.1(Fe- 415, Fe- 415D, Fe-500, Fe-500D, Fe-550, Fe-550D, Fe-600 NITROGEN) |
- |
500 |
|
- |
| Clause - 4.2 & 4.2.1(Fe- 415, Fe- 415D, Fe-500, Fe-500D, Fe-550, Fe-550D, Fe-600 PHOSPHURS) |
- |
500 |
|
- |
| Clause - 4.2 & 4.2.1(Fe- 415, Fe- 415D, Fe-500, Fe-500D, Fe-550, Fe-550D, Fe-600 SULPHUR) |
- |
500 |
|
- |
| Clause - 4.2 & 4.2.1(Fe- 415, Fe- 415D, Fe-500, Fe-500D, Fe-550, Fe-550D, Fe-600 CARBON ) |
- |
500 |
|
- |
| Cl.4.2 of IS 1786 (Vanadium- IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
500 |
|
- |
| Cl.4.2 of IS 1786 (Molybdenum- IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
500 |
|
- |
| Cl.4.2 of IS 1786 (Chromium- IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
500 |
|
- |
| Cl.4.2 of IS 1786 (Nickel- IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
500 |
|
- |
| Cl.4.2 of IS 1786 (Copper- IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
500 |
|
- |
| Cl.4.2 of IS 1786 (Manganese- IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
500 |
|
- |
| Cl.4.2 of IS 1786 (Grade:- Fe 415D,Fe 415S, Fe 500D,Fe 500S,Fe 550D)(Carbon Equivalent) |
- |
500 |
|
- |
| Cl.4.2 of IS 1786 (Grade:- Fe 415,Fe 415D,Fe 415S,Fe 500,Fe 500D,Fe 500S,Fe 550,Fe 550D,Fe600,Fe 650,Fe 700)(Sulphur & Phosphorous) |
- |
500 |
|
- |
| Cl.4.2 of IS 1786 (Grade:- Fe 415,Fe 415D,Fe 415S,Fe 500,Fe 500D,Fe 500S,Fe 550,Fe 550D,Fe600,Fe 650,Fe 700)(Phosphorous- IS 228) |
- |
500 |
|
- |
| Cl.4.2 of IS 1786 (Grade:- Fe 415,Fe 415D,Fe 415S,Fe 500,Fe 500D,Fe 500S,Fe 550,Fe 550D,Fe600,Fe 650,Fe 700)(Sulphur-IS 228) |
- |
500 |
|
- |
| Cl.4.2 of IS 1786 (Grade:- Fe 415,Fe 415D,Fe 415S,Fe 500,Fe 500D,Fe 500S,Fe 550,Fe 550D,Fe600,Fe 650,Fe 700)(Carbon-IS 228) |
- |
500 |
|
- |
| 8.18.1 Table 3(Total elongation at maximum force) |
- |
1000 |
|
- |
| Cl 5(Deformations and Surface Characteristics) |
- |
500 |
|
- |
| 5.7(PullOut (Bond Test)) |
- |
0 |
|
- |
| 4.2(Niobium (Nb)) |
- |
500 |
|
- |
| 4.2(Boron (B)) |
- |
500 |
|
- |
| Cl. 5.7(Average compressive strength of cubes at 28 days) |
- |
0 |
|
- |
| Cl. 5.7(Bond Strength at 0.25 mm slip) |
- |
0 |
|
- |
| Cl. 5.7(Date of testing of concrete cubes) |
- |
0 |
|
- |
| Cl. 5.7(Date of casting of concrete cubes) |
- |
0 |
|
- |
| Cl. 8.1 Table 3(TS/YS Ratio) |
- |
500 |
|
- |
| Cl. 5.3 (b)(The ribs contributing the projected area - Transverse Ribs) |
- |
500 |
|
- |
| Cl. 5.3 (a)(The ribs contributing the projected area - Longitudinal Ribs) |
- |
500 |
|
- |
| Cl. 8.1 Table 3(Maximum Extension) |
- |
1000 |
|
- |
| Cl. 8.1 Table 3(Total Elongation at Maximum Force) |
- |
1000 |
|
- |
| Cl. 6.2, 6.3 Table 1(Gross Cross Sectional Area, A) |
- |
500 |
|
- |
| Cl. 4.3(Visual Inspection.) |
- |
500 |
|
- |
| Cl. 5.2(Surface Characteristics) |
- |
500 |
|
- |
| Clause 9.4(Rebend Test) |
- |
1000 |
|
- |
| Clause 6.3(Effective Cross-sectional Area) |
- |
500 |
|
- |
| Clause 8.1(Table 3)(Total Elongation at Maximum Force) |
- |
1000 |
|
- |
| Cl 9.3(Load In One Direction) |
- |
500 |
|
- |
| Cl 8.1(UTM) |
- |
1000 |
|
- |
| Cl 7.2(Weight) |
- |
500 |
|
- |
| Cl 6.1(Length, Width & Thickness) |
- |
500 |
|
- |
| Cl 5(Deformations and Surface Characteristics) |
- |
500 |
|
- |
| Cl 5(Deformations and Surface Characteristics) |
- |
500 |
|
- |
| Cl 6.1(Length, Width & Thickness) |
- |
500 |
|
- |
| Cl 7.2(Weight) |
- |
500 |
|
- |
| Cl 8.1(UTM) |
- |
1000 |
|
- |
| Cl 9.3(Load In One Direction) |
- |
500 |
|
- |
| Cl 9.4(Load In Other Direction From Bend) |
- |
1000 |
|
- |
| 13(Identification and marking) |
- |
500 |
|
- |
| 5.7(Pull-out test - IS:2770(P1)) |
- |
0 |
|
- |
| 7.0 & 7.1(Specified lengths - SOP MT-23) |
- |
500 |
|
- |
| 8.0 & 8.1("Total elongation at maximum force on
5.65 vSo mm GL.
") |
- |
500 |
|
- |
| 4.3(Rolling and cold working of bars/wire) |
- |
500 |
|
- |
| 7.1(Specified length) |
- |
500 |
|
- |
| 9.1(Preparation of test sample) |
- |
500 |
|
- |
| 9.2(Tensile test,IS:1608(Pt1)-2018) |
- |
1000 |
|
- |
| 9.5(Retest) |
- |
0 |
|
- |
| 12(Inspection) |
- |
0 |
|
- |
| Clause 4.2 Note 2, Amendment 1 & 3(Nb+V+B+Ti) |
- |
500 |
|
- |
| Clause 4.2 Note 3, Amendment 1 & 3(Cr+Cu+Ni+Mo+P) |
- |
500 |
|
- |
| Clause 4.2, Amendment 3 Note 4("In order to ascertain whether sufficient quantities of nitrogen binding elements are present, following formula may be used, where all elements are in ppm.
(N−120)< (Al free/10)+((Ti+V)/7)+(Nb/14)") |
- |
500 |
|
- |
| 1() |
- |
0 |
|
- |
| Cl 5(Deformations and Surface Characteristics) |
- |
500 |
|
- |
| Cl.4.2 of IS 1786 (Nitrogen- IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
500 |
|
- |
| Cl 9.4(Load In Other Direction From Bend) |
- |
500 |
|
- |
| Cl 5(Deformations and Surface Characteristics) |
- |
500 |
|
- |
| Cl.4.2 of IS 1786 (Vanadium- IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
500 |
|
- |
| Cl.4.2 of IS 1786 (Molybdenum- IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
500 |
|
- |
| Cl.4.2 of IS 1786 (Chromium- IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
500 |
|
- |
| Cl.4.2 of IS 1786 (Nickel- IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
500 |
|
- |
| Cl.4.2 of IS 1786 (Copper- IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
500 |
|
- |
| Cl.4.2 of IS 1786 (Manganese- IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
500 |
|
- |
| Cl.4.2 of IS 1786 (Grade:- Fe 415D,Fe 415S, Fe 500D,Fe 500S,Fe 550D)(Carbon Equivalent) |
- |
500 |
|
- |
| Cl.4.2 of IS 1786 (Grade:- Fe 415,Fe 415D,Fe 415S,Fe 500,Fe 500D,Fe 500S,Fe 550,Fe 550D,Fe600,Fe 650,Fe 700)(Sulphur & Phosphorous) |
- |
500 |
|
- |
| Cl.4.2 of IS 1786 (Grade:- Fe 415,Fe 415D,Fe 415S,Fe 500,Fe 500D,Fe 500S,Fe 550,Fe 550D,Fe600,Fe 650,Fe 700)(Phosphorous- IS 228) |
- |
500 |
|
- |
| Cl.4.2 of IS 1786 (Grade:- Fe 415,Fe 415D,Fe 415S,Fe 500,Fe 500D,Fe 500S,Fe 550,Fe 550D,Fe600,Fe 650,Fe 700)(Sulphur-IS 228) |
- |
500 |
|
- |
| Cl.4.2 of IS 1786 (Grade:- Fe 415,Fe 415D,Fe 415S,Fe 500,Fe 500D,Fe 500S,Fe 550,Fe 550D,Fe600,Fe 650,Fe 700)(Carbon-IS 228) |
- |
500 |
|
- |
| 8.18.1 Table 3(Total elongation at maximum force) |
- |
1000 |
|
- |
| Cl 5(Deformations and Surface Characteristics) |
- |
500 |
|
- |
| 5.7(PullOut (Bond Test)) |
- |
0 |
|
- |
| 4.2(Niobium (Nb)) |
- |
500 |
|
- |
| 4.2(Boron (B)) |
- |
500 |
|
- |
| Cl. 5.7(Average compressive strength of cubes at 28 days) |
- |
0 |
|
- |
| Cl. 5.7(Bond Strength at 0.25 mm slip) |
- |
0 |
|
- |
| Cl. 5.7(Date of testing of concrete cubes) |
- |
0 |
|
- |
| Cl. 5.7(Date of casting of concrete cubes) |
- |
0 |
|
- |
| Cl. 8.1 Table 3(TS/YS Ratio) |
- |
1000 |
|
- |
| Cl. 5.3 (b)(The ribs contributing the projected area - Transverse Ribs) |
- |
500 |
|
- |
| Cl. 5.3 (a)(The ribs contributing the projected area - Longitudinal Ribs) |
- |
500 |
|
- |
| Cl. 8.1 Table 3(Maximum Extension) |
- |
1000 |
|
- |
| Cl. 8.1 Table 3(Total Elongation at Maximum Force) |
- |
1000 |
|
- |
| Cl. 6.2, 6.3 Table 1(Gross Cross Sectional Area, A) |
- |
500 |
|
- |
| Cl. 4.3(Visual Inspection.) |
- |
500 |
|
- |
| Cl. 5.2(Surface Characteristics) |
- |
500 |
|
- |
| Clause 9.4(Rebend Test) |
- |
500 |
|
- |
| Clause 6.3(Effective Cross-sectional Area) |
- |
500 |
|
- |
| Clause 8.1(Table 3)(Total Elongation at Maximum Force) |
- |
1000 |
|
- |
| Cl 9.3(Load In One Direction) |
- |
1000 |
|
- |
| Cl 8.1(UTM) |
- |
1000 |
|
- |
| Cl 7.2(Weight) |
- |
500 |
|
- |
| Cl 6.1(Length, Width & Thickness) |
- |
500 |
|
- |
| Cl 5(Deformations and Surface Characteristics) |
- |
500 |
|
- |
| Cl 5(Deformations and Surface Characteristics) |
- |
500 |
|
- |
| Cl 6.1(Length, Width & Thickness) |
- |
500 |
|
- |
| Cl 7.2(Weight) |
- |
500 |
|
- |
| Cl 8.1(UTM) |
- |
1000 |
|
- |
| Cl 9.3(Load In One Direction) |
- |
1000 |
|
- |
| Cl 9.4(Load In Other Direction From Bend) |
- |
1000 |
|
- |
| 13(Identification and marking) |
- |
500 |
|
- |
| 5.7(Pull-out test - IS:2770(P1)) |
- |
0 |
|
- |
| 7.0 & 7.1(Specified lengths - SOP MT-23) |
- |
500 |
|
- |
| 8.0 & 8.1("Total elongation at maximum force on
5.65 vSo mm GL.
") |
- |
1000 |
|
- |
| 4.3(Rolling and cold working of bars/wire) |
- |
500 |
|
- |
| 7.1(Specified length) |
- |
500 |
|
- |
| 9.1(Preparation of test sample) |
- |
500 |
|
- |
| 9.2(Tensile test,IS:1608(Pt1)-2018) |
- |
1000 |
|
- |
| 9.5(Retest) |
- |
500 |
|
- |
| 12(Inspection) |
- |
500 |
|
- |
| Clause 4.2 Note 2, Amendment 1 & 3(Nb+V+B+Ti) |
- |
500 |
|
- |
| Clause 4.2 Note 3, Amendment 1 & 3(Cr+Cu+Ni+Mo+P) |
- |
500 |
|
- |
| Clause 4.2, Amendment 3 Note 4("In order to ascertain whether sufficient quantities of nitrogen binding elements are present, following formula may be used, where all elements are in ppm.
(N−120)< (Al free/10)+((Ti+V)/7)+(Nb/14)") |
- |
500 |
|
- |
| 1() |
- |
0 |
|
- |
| Cl.4.2 of IS 1786 (Nitrogen- IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
500 |
|
- |
| Cl 9.4(Load In Other Direction From Bend) |
- |
500 |
|
- |
| Cl 5(Deformations and Surface Characteristics) |
- |
500 |
|
- |
| Cl.4.2 of IS 1786 (Vanadium- IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
500 |
|
- |
| Cl.4.2 of IS 1786 (Molybdenum- IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
500 |
|
- |
| Cl.4.2 of IS 1786 (Chromium- IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
500 |
|
- |
| Cl.4.2 of IS 1786 (Nickel- IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
500 |
|
- |
| Cl.4.2 of IS 1786 (Copper- IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
500 |
|
- |
| Cl.4.2 of IS 1786 (Manganese- IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
500 |
|
- |
| Cl.4.2 of IS 1786 (Grade:- Fe 415D,Fe 415S, Fe 500D,Fe 500S,Fe 550D)(Carbon Equivalent) |
- |
500 |
|
- |
| Cl.4.2 of IS 1786 (Grade:- Fe 415,Fe 415D,Fe 415S,Fe 500,Fe 500D,Fe 500S,Fe 550,Fe 550D,Fe600,Fe 650,Fe 700)(Sulphur & Phosphorous) |
- |
500 |
|
- |
| Cl.4.2 of IS 1786 (Grade:- Fe 415,Fe 415D,Fe 415S,Fe 500,Fe 500D,Fe 500S,Fe 550,Fe 550D,Fe600,Fe 650,Fe 700)(Phosphorous- IS 228) |
- |
500 |
|
- |
| Cl.4.2 of IS 1786 (Grade:- Fe 415,Fe 415D,Fe 415S,Fe 500,Fe 500D,Fe 500S,Fe 550,Fe 550D,Fe600,Fe 650,Fe 700)(Sulphur-IS 228) |
- |
500 |
|
- |
| Cl.4.2 of IS 1786 (Grade:- Fe 415,Fe 415D,Fe 415S,Fe 500,Fe 500D,Fe 500S,Fe 550,Fe 550D,Fe600,Fe 650,Fe 700)(Carbon-IS 228) |
- |
500 |
|
- |
| 8.18.1 Table 3(Total elongation at maximum force) |
- |
500 |
|
- |
| Cl 5(Deformations and Surface Characteristics) |
- |
500 |
|
- |
| 5.7(PullOut (Bond Test)) |
- |
500 |
|
- |
| 4.2(Niobium (Nb)) |
- |
500 |
|
- |
| 4.2(Boron (B)) |
- |
500 |
|
- |
| Cl. 5.7(Average compressive strength of cubes at 28 days) |
- |
500 |
|
- |
| Cl. 5.7(Bond Strength at 0.25 mm slip) |
- |
500 |
|
- |
| Cl. 5.7(Date of testing of concrete cubes) |
- |
500 |
|
- |
| Cl. 5.7(Date of casting of concrete cubes) |
- |
500 |
|
- |
| Cl. 8.1 Table 3(TS/YS Ratio) |
- |
500 |
|
- |
| Cl. 5.3 (b)(The ribs contributing the projected area - Transverse Ribs) |
- |
500 |
|
- |
| Cl. 5.3 (a)(The ribs contributing the projected area - Longitudinal Ribs) |
- |
500 |
|
- |
| Cl. 8.1 Table 3(Maximum Extension) |
- |
500 |
|
- |
| Cl. 8.1 Table 3(Total Elongation at Maximum Force) |
- |
500 |
|
- |
| Cl. 6.2, 6.3 Table 1(Gross Cross Sectional Area, A) |
- |
500 |
|
- |
| Cl. 4.3(Visual Inspection.) |
- |
500 |
|
- |
| Cl. 5.2(Surface Characteristics) |
- |
500 |
|
- |
| Clause 9.4(Rebend Test) |
- |
500 |
|
- |
| Clause 6.3(Effective Cross-sectional Area) |
- |
500 |
|
- |
| Clause 8.1(Table 3)(Total Elongation at Maximum Force) |
- |
500 |
|
- |
| Cl 9.3(Load In One Direction) |
- |
500 |
|
- |
| Cl 8.1(UTM) |
- |
500 |
|
- |
| Cl 7.2(Weight) |
- |
500 |
|
- |
| Cl 6.1(Length, Width & Thickness) |
- |
500 |
|
- |
| Cl 5(Deformations and Surface Characteristics) |
- |
500 |
|
- |
| Cl 5(Deformations and Surface Characteristics) |
- |
500 |
|
- |
| Cl 6.1(Length, Width & Thickness) |
- |
500 |
|
- |
| Cl 7.2(Weight) |
- |
500 |
|
- |
| Cl 8.1(UTM) |
- |
500 |
|
- |
| Cl 9.3(Load In One Direction) |
- |
500 |
|
- |
| Cl 9.4(Load In Other Direction From Bend) |
- |
500 |
|
- |
| 13(Identification and marking) |
- |
500 |
|
- |
| 5.7(Pull-out test - IS:2770(P1)) |
- |
500 |
|
- |
| 7.0 & 7.1(Specified lengths - SOP MT-23) |
- |
500 |
|
- |
| 8.0 & 8.1("Total elongation at maximum force on
5.65 vSo mm GL.
") |
- |
500 |
|
- |
| 4.3(Rolling and cold working of bars/wire) |
- |
500 |
|
- |
| 7.1(Specified length) |
- |
500 |
|
- |
| 9.1(Preparation of test sample) |
- |
500 |
|
- |
| 9.2(Tensile test,IS:1608(Pt1)-2018) |
- |
500 |
|
- |
| 9.5(Retest) |
- |
500 |
|
- |
| 12(Inspection) |
- |
500 |
|
- |
| Clause 4.2 Note 2, Amendment 1 & 3(Nb+V+B+Ti) |
- |
500 |
|
- |
| Clause 4.2 Note 3, Amendment 1 & 3(Cr+Cu+Ni+Mo+P) |
- |
500 |
|
- |
| Clause 4.2, Amendment 3 Note 4("In order to ascertain whether sufficient quantities of nitrogen binding elements are present, following formula may be used, where all elements are in ppm.
(N−120)< (Al free/10)+((Ti+V)/7)+(Nb/14)") |
- |
500 |
|
- |
| 1() |
- |
500 |
|
- |
| Cl.4.2 of IS 1786 (Nitrogen- IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
500 |
|
- |
| Cl 9.4(Load In Other Direction From Bend) |
- |
500 |
|
- |
|
28 Nov, 2028 |
- Included w.e.f 24.03.2026
Exclusion: Cl 5.7 (PullOut (Bond Test)) |
| 1443 |
URS PRODUCTS AND TESTING PVT. LTD. (A29), NOIDA
| 8168906
| IS 302 : Part 2 : Sec 23 (2009) |
Safety of household and similar electrical appliances: Part 2 particular requirements: Sec 23 appliances for skin or hair care (First Revision) |
- |
50000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 32(Radiation ,Toxicity and similar hazards) |
- |
1000 |
|
50000/- Without EMI/EMC and 250000/- with EMI/EMC |
| 31(Resistance to Rusting) |
- |
1000 |
|
50000/- Without EMI/EMC and 250000/- with EMI/EMC |
| 30(Resistance to Heat & Fire) |
- |
4000 |
|
50000/- Without EMI/EMC and 250000/- with EMI/EMC |
| 29(Clearances, Creepage Distances & Solid Insulation) |
- |
1000 |
|
50000/- Without EMI/EMC and 250000/- with EMI/EMC |
| 28(Screws & Connection) |
- |
1000 |
|
50000/- Without EMI/EMC and 250000/- with EMI/EMC |
| 27(Provision For Earthing) |
- |
1000 |
|
50000/- Without EMI/EMC and 250000/- with EMI/EMC |
| 26(Terminals For External Conductors) |
- |
2500 |
|
50000/- Without EMI/EMC and 250000/- with EMI/EMC |
| 25(Supply Connection & External Flexible Cables and Cords) |
- |
3000 |
|
50000/- Without EMI/EMC and 250000/- with EMI/EMC |
| 24(Component) |
- |
3000 |
|
50000/- Without EMI/EMC and 250000/- with EMI/EMC |
| 23(Internal wiring) |
- |
1500 |
|
50000/- Without EMI/EMC and 250000/- with EMI/EMC |
| 22(Construction) |
- |
2500 |
|
50000/- Without EMI/EMC and 250000/- with EMI/EMC |
| 21(Mechanical strength) |
- |
2000 |
|
50000/- Without EMI/EMC and 250000/- with EMI/EMC |
| 20(Stability & Mechanical Hazards) |
- |
1000 |
|
50000/- Without EMI/EMC and 250000/- with EMI/EMC |
| 19(Abnormal Operation) |
- |
4000 |
|
50000/- Without EMI/EMC and 250000/- with EMI/EMC |
| 18(Endurance) |
- |
0 |
|
50000/- Without EMI/EMC and 250000/- with EMI/EMC |
| 17(Overload Protection/ Overload Protection of Transformers & Associated Circuits) |
- |
2000 |
|
50000/- Without EMI/EMC and 250000/- with EMI/EMC |
| 16(Leakage Current and Electric Strength) |
- |
1500 |
|
50000/- Without EMI/EMC and 250000/- with EMI/EMC |
| 15(Moisture Resistance) |
- |
5000 |
|
50000/- Without EMI/EMC and 250000/- with EMI/EMC |
| 14(Transient Over Voltage) |
- |
3500 |
|
50000/- Without EMI/EMC and 250000/- with EMI/EMC |
| 13(Leakage Current and Electric Strength at Operating Temperature) |
- |
1500 |
|
50000/- Without EMI/EMC and 250000/- with EMI/EMC |
| 11(Temperature Rise/Heating) |
- |
3500 |
|
50000/- Without EMI/EMC and 250000/- with EMI/EMC |
| 10(Power Input
& Current) |
- |
2000 |
|
50000/- Without EMI/EMC and 250000/- with EMI/EMC |
| 9(Starting Of Motor Operated Appliances) |
- |
0 |
|
50000/- Without EMI/EMC and 250000/- with EMI/EMC |
| 8(Protection against Electric Shock/ Protection against Access to Live Parts) |
- |
1000 |
|
50000/- Without EMI/EMC and 250000/- with EMI/EMC |
| 7(Marking/ Marking & Instructions) |
- |
1000 |
|
50000/- Without EMI/EMC and 250000/- with EMI/EMC |
| 6(Classification) |
- |
500 |
|
50000/- Without EMI/EMC and 250000/- with EMI/EMC |
| 22.32(CONSTRUCTION) |
- |
0 |
|
50000/- Without EMI/EMC and 250000/- with EMI/EMC
Refer to Clause No. 22 |
| 19.11.4.1(Electrostatic discharges) |
- |
25000 |
|
50000/- Without EMI/EMC and 250000/- with EMI/EMC |
| 19.11.4.2(Radiated fields) |
- |
45000 |
|
50000/- Without EMI/EMC and 250000/- with EMI/EMC |
| 19.11.4.3(Fast transient bursts) |
- |
25000 |
|
50000/- Without EMI/EMC and 250000/- with EMI/EMC |
| 19.11.4.4(Surge immunity test) |
- |
25000 |
|
50000/- Without EMI/EMC and 250000/- with EMI/EMC |
| 19.11.4.5(Immunity to conducted discharges) |
- |
30000 |
|
50000/- Without EMI/EMC and 250000/- with EMI/EMC |
| 19.11.4.6(Class 3 Voltage dips and interruptions) |
- |
25000 |
|
50000/- Without EMI/EMC and 250000/- with EMI/EMC |
| 19.11.4.7(Harmonics) |
- |
25000 |
|
50000/- Without EMI/EMC and 250000/- with EMI/EMC |
|
- |
- Included w.e.f. 14.01.2026 |
| 1444 |
EKO PRO ENGINEERS PRIVATE LIMITED (32/41), GHAZIABAD
| 9179706
| IS 15298 : Part 2 (2016) |
Personal protective equipment: Part 2 safety footwear (Second Revision) |
ALL |
60000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4,Table 1(Class I, IS 15298) |
- |
1000 |
|
- |
| 4,Table 1(Class II, IS 15298) |
- |
1000 |
|
- |
| 5.2,5.2.1, Fig 3(Design,General, IS 15298) |
- |
1000 |
|
- |
| 5.2.2, Fig 4(Height of Upper, ISO 20344 , 6.2) |
- |
600 |
|
- |
| 5.2.3, Table 10 ,Design A(Seat Region) |
- |
600 |
|
- |
| 5.3.1.1(Construction) |
- |
500 |
|
- |
| 5.3.1.2(Upper/outer sole bond strength , ISO 20344 , 5.2) |
- |
600 |
|
- |
| 5.3.2.1(General, EN 12568 OF 4.2.2.2) |
- |
700 |
|
- |
| 5.3.2.2,Table 5(Internal length of toecaps , ISO 20344 , 5.3) |
- |
600 |
|
- |
| 5.3.2.3,Table 6(Impact resistance of safety footwear,ISO 20344 , 5.4) |
- |
700 |
|
- |
| 5.3.2.4 ,Table 6(Compression Resistance of safety footwear ,ISO20344 , 5.5) |
- |
700 |
|
- |
| 5.3.2.5.1(Corrosion resistance of metallic toecaps ,ISO20344 , 5.6.2) |
- |
600 |
|
- |
| 5.3.2.5.2(Non metallic toe caps ,EN 12568) |
- |
500 |
|
- |
| 5.3.3(Leak proofness ,ISO 20344 , 5.7) |
- |
800 |
|
- |
| 5.3.4(Specific ergonomic feature ,ISO 20344 , 5.1) |
- |
700 |
|
- |
| 5.3.5.2,Table 7(Slip resistance on ceramic tile floor with sodium lauryl sulphate (NaLS) solution) |
- |
700 |
|
- |
| 5.3.5.3,Table 8(Slip resistance on steel floor with glycerin) |
- |
800 |
|
- |
| 5.3.5.4(Slip resistance on ceramic tile floor with NaLS and on steel floor with glycerin) |
- |
800 |
|
- |
| 5.3.6(Innocuousness) |
- |
700 |
|
- |
| 5.4.1,Table 10(General) |
- |
500 |
|
- |
| 5.4.2, Table 11(Thickness , ISO 20344 , 6.1 ) |
- |
500 |
|
- |
| 5.4.3, Table 12(Tear Strength, ISO 20344 , 6.3 ) |
- |
700 |
|
- |
| 5.4.4, Table 13(Tensile properties ,ISO 20344 , 6.4.1 ) |
- |
700 |
|
- |
| 5.4.5, Table 14(Flexing resistance ,ISO 20344,6.5) |
- |
600 |
|
- |
| 5.4.6(Water vapour permeability and coefficient,ISO 20344,6.6 & 6.8) |
- |
600 |
|
- |
| 5.4.7(Ph Value ; ISO 20344,6.9) |
- |
500 |
|
- |
| 5.4.8(Hydrolysis ; ISO 20344,6.10) |
- |
600 |
|
- |
| 5.4.9(Chromium VI content; ISO 17075) |
- |
700 |
|
- |
| 5.5.1,Table 15(Tear Strength, ISO 20344 , 6.3) |
- |
700 |
|
- |
| 5.5.2(Abrasion Resistance ;ISO 20344 , 6.12) |
- |
600 |
|
- |
| 5.5.3(Water vapour permeability and coefficient,ISO 20344,6.6 & 6.8) |
- |
600 |
|
- |
| 5.5.4(Ph Value ; ISO 20344,6.9) |
- |
500 |
|
- |
| 5.5.5(Chromium VI content; ISO 17075) |
- |
700 |
|
- |
| 5.6(Tongue - IS 15298 Part 2 ) |
- |
700 |
|
- |
| 5.6.1,Table 16(Tear Strength, ISO 20344 , 6.3) |
- |
700 |
|
- |
| 5.6.2(Ph Value ; ISO 20344,6.9) |
- |
500 |
|
- |
| 5.6.3(Chromium VI content; ISO 17075) |
- |
700 |
|
- |
| 5.7.1;Table 3(Thickness ; ISO 20344,7.1) |
- |
500 |
|
- |
| 5.7.2(Ph Value ; ISO 20344,6.9) |
- |
500 |
|
- |
| 5.7.3(Water Absorption and desorption ISO 20344,7.2 ) |
- |
700 |
|
- |
| 5.7.4.1(Insole ; ISO 20344,7.3 ) |
- |
600 |
|
- |
| 5.7.4.2(Insocks ; ISO 20344, 6.12) |
- |
600 |
|
- |
| 5.7.5(Chromium VI content; ISO 17075) |
- |
1000 |
|
- |
| 5.8.1(Design, IS 15298 Part 2 ) |
- |
500 |
|
- |
| 5.8.1.1, Table 17(Thickness ; ISO 20344, 8.1.2) |
- |
500 |
|
- |
| 5.8.1.2(Cleated area ; ISO 20344 , Fig 38) |
- |
600 |
|
- |
| 5.8.1.3, Table 17(Cleat height; ISO 20344, 8.1) |
- |
600 |
|
- |
| 5.8.2(Tear Strength, ISO 20344 , 8.2) |
- |
700 |
|
- |
| 5.8.3(Abrasion Resistance ;ISO 20344 , 8.3) |
- |
700 |
|
- |
| 5.8.4(Flexing resistance ,ISO 20344,8.4) |
- |
700 |
|
- |
| 5.8.5(Hydrolysis ; ISO 20344,8.5) |
- |
700 |
|
- |
| 5.8.6(Interlayer bond strength; ISO 20344, 5.2) |
- |
800 |
|
- |
| 6.2.1.1.1(Metallic anti-penetration insert; ISO 20344, 5.8.2) |
- |
700 |
|
- |
| 6.2.1.1.2(Non-metallic anti-penetration insert; ISO 20344, 5.8.3) |
- |
700 |
|
- |
| 6.2.1.2(Consruction) |
- |
600 |
|
- |
| 6.2.1.3(Dimension ; ISO 20344, 5.8.1) |
- |
500 |
|
- |
| 6.2.1.4(Flex resistance of penetration -resistant insert ; ISO 20344,5.9) |
- |
700 |
|
- |
| 6.2.1.5.1(Corrosion resistance of penetration -resistant metallic insert - ISO 20344, 5.6.3 &5.6.1) |
- |
700 |
|
- |
| 6.2.1.5.2(Penetration -resistant non-metallic insert ; EN 12568,6.4&7.4) |
- |
700 |
|
- |
| 6.2.2.1 (Conductive footwear ; ISO 20344,5.10 & 5.10.3.3) |
- |
800 |
|
- |
| 6.2.2.2(Antistatic footwear ; ISO 20344,5.10) |
- |
800 |
|
- |
| 6.2.2.3(Electrically insulating footwear; EN 50321) |
- |
600 |
|
- |
| 6.2.3.1(Hear insulation of sole complex; ISO 20344,5.12 ;Annex B) |
- |
600 |
|
- |
| 6.2.3.2(Cold insulation of sole complex; ISO 20344,5.13) |
- |
600 |
|
- |
| 6.2.4(Energy absorption of seat region; ISO 20344,5.14) |
- |
600 |
|
- |
| 6.2.5(Water resistance ; 5.15.1 & 5.15.2) |
- |
700 |
|
- |
| 6.2.6.1(Construction) |
- |
600 |
|
- |
| 6.2.6.2 , Table 19(Impact resistance of metatarsal protective device,ISO 20344 , 5.16) |
- |
700 |
|
- |
| 6.2.7 (Ankle protection ; ISO 20344 , 5.17) |
- |
0 |
|
- |
| 6.2.8.1(Design) |
- |
500 |
|
- |
| 6.2.8.2(Construction) |
- |
600 |
|
- |
| 6.2.8.3,EN 388(Resistance to cutting ,EN 388) |
- |
600 |
|
- |
| 6.2.8.4(Penetration Resistance) |
- |
600 |
|
- |
| 6.3(Upper--Water penetration and absorption ; ISO 20344 , 5.13) |
- |
600 |
|
- |
| 6.4.1(Resistance to hot contact ; ISO 20344 , 8.7) |
- |
600 |
|
- |
| 6.4.2(Resistance to fuel oil ; ISO 20344 , 8.6.1& 8.6.2 ; ) |
- |
600 |
|
- |
| Cl.5.3.5.1, Cl.5.3.5.2,Cl.5.3.5.3 or 5.3.5.4 IS 15298 (Part1):2015,ISO 20344:2011,5.11(General) |
- |
800 |
|
- |
| Cl.7, table 2,table 18,table 20, table21, EN 13832-1,EN 13832-3: 2006,6.2.2.3(Marking) |
- |
800 |
|
- |
| 8(Information to be supplied) |
- |
700 |
|
- |
| Cl.8.1 IS 15298 Part 2:2016 + A1:2019 + A2:2019, ISO 20345 :2011(General) |
- |
1000 |
|
- |
| 8.2(Electrical Properties) |
- |
800 |
|
- |
| 8.2.2(Antistatic footwear) |
- |
700 |
|
- |
| 8.3(Insocks) |
- |
800 |
|
- |
| Cl.5.7.3(Water absorption and desorption) |
- |
600 |
|
- |
| Cl.5.7.2(PH value) |
- |
500 |
|
- |
| 5.5.1(Tear strength) |
- |
600 |
|
- |
| 5.5.2(Abrasion Resistance) |
- |
600 |
|
- |
| 5.5.3(W.V.P & W.V.C) |
- |
600 |
|
- |
| 5.7.1(Insole thickness) |
- |
500 |
|
- |
| 5.7.4.2(Insock abrasion) |
- |
600 |
|
- |
| 5.8.1.2(Cleated area) |
- |
600 |
|
- |
| 5.8.4(Flexing resistance) |
- |
800 |
|
- |
| 5.8.1.1(Thickness) |
- |
500 |
|
- |
| 5.8.1.3(Cleat height) |
- |
500 |
|
- |
| Cl-5.3.6 (IS 17011, Table-1 (i)(Allergenic and carcinogenic disperse dyes) |
- |
800 |
|
- |
| Cl-5.3.6 (IS 17011, Table-1 (ii)(Aromatic amines released from Azo dyes (each individual amine)) |
- |
600 |
|
- |
| Cl-5.3.6 (IS 17011, Table-1 (iii)(Aromatic amines released from Azo dyes (each individual amine)) |
- |
600 |
|
- |
| Cl-5.3.6 (IS 17011, Table-1 (iv)(Chromium (VI)) |
- |
700 |
|
- |
| Cl-5.3.6 (IS 17011, Table-1 (v)(Dimethyl fumarate (DMFU)) |
- |
800 |
|
- |
| Cl-5.3.6 (IS 17011, Table-1 (vi)(Formaldehyde (free or released by partial hydrolysis)) |
- |
700 |
|
- |
| Cl-5.3.6 (IS 17011, Table-1 (vii)(Formaldehyde) |
- |
700 |
|
- |
| Cl-5.3.6 (IS 17011, Table-1 (v)(Dimethyl fumarate (DMFU)) |
- |
700 |
|
- |
| Cl-5.3.6 (IS 17011, Table-1 (vi)(Formaldehyde (free or released by partial hydrolysis)) |
- |
700 |
|
- |
| Cl-5.3.6 (IS 17011, Table-1 (vii)(Formaldehyde) |
- |
800 |
|
- |
| Cl-5.3.6 (IS 17011, Table-1 (viii)(Organotin compounds) |
- |
800 |
|
- |
| Cl-5.3.6 (IS 17011, Table-1 (ix)(PCP-TeCP-TriCP polychlorophenols) |
- |
1000 |
|
- |
| Cl-5.3.6 (IS 17011, Table-1 (x)(pH) |
- |
500 |
|
- |
| Cl-5.3.6 (IS 17011, Table-1 (xi)(Phthalates (each individual phthalate)) |
- |
800 |
|
- |
| Cl-5.3.6 (IS 17011, Table-1 (xii)(Nickel, on skin contact) |
- |
800 |
|
- |
| Cl.1.4.1 of IS 17011 (Table B Sl I )(Phthalate: DINP) |
- |
800 |
|
- |
| Cl.1.4.1 of IS 17011 (Table B Sl II )(Phthalate:: DNOP) |
- |
1000 |
|
- |
| Cl.1.4.1 of IS 17011 (Table B Sl III )(Phthalate: DEHP) |
- |
1000 |
|
- |
| Cl.1.4.1 of IS 17011 (Table B Sl IV )(Phthalate: DIDP) |
- |
1000 |
|
- |
| Cl.1.4.1 of IS 17011 (Table B Sl V)(Phthalate: BBP) |
- |
1000 |
|
- |
| Cl.1.4.1 of IS 17011 (Table B Sl VI )(Phthalate:DBP) |
- |
1000 |
|
- |
| Cl.1.4.1 of IS 17011 (Table B Sl VII )(Phthalate: DIBP) |
- |
1000 |
|
- |
| Cl.4.1 (Annex-A Sl I )(Organotin: Dibutyltin) |
- |
1000 |
|
- |
| Cl.4.1 (Annex-A Sl II )(Organotin: Dibutyltin Dichloride) |
- |
1000 |
|
- |
| Cl.4.1 (Annex-A Sl III )(Organotin: Dioctyltin) |
- |
1000 |
|
- |
| Cl.4.1 (Annex-A Sl IV)(Organotin: Monobutyltin) |
- |
1000 |
|
- |
| Cl.4.1 (Annex-A Sl V )(Organotin: Tributyltin) |
- |
1000 |
|
- |
| Cl.4.1 (Annex-A Sl VI)(Organotin: Triphenyltin) |
- |
1000 |
|
- |
| Cl.4.1 (Annex-A Sl VII )(Organotin: Monoctyltin) |
- |
1000 |
|
- |
| Cl.4.1 (Annex-A Sl VIII)(Organotin: Bis (tributyltin) oxide) |
- |
1000 |
|
- |
| Cl.1.4.1 of IS 17011(DMFU) |
- |
1000 |
|
- |
| Cl. No.8.6.1,Table 1 of IS 17011(Chromium (VI)) |
- |
1000 |
|
- |
| Cl. No.8.6.1,Table 1 of IS 17011(Formaldehyde (free or released by partial hydrolysis)) |
- |
1000 |
|
- |
| Cl. No.8.6.1,Table 1 of IS 17011(Nickel, on skin contact 2-(thiocyanomethylthio) -benzothiazole (TCMTB)) |
- |
1000 |
|
- |
| Cl.8 - Table No 1(Lead Content (as Pb) (applicable for PVC only) - IS 12240 (Part 5) : 1988) |
- |
1000 |
|
- |
| Cl.4.1 (Table B-3 Sl I)(Allergenic Disperse Dyes :Disperse blue 3) |
- |
1000 |
|
- |
| Cl.4.1 (Table B-3 Sl II)(Allergenic Disperse Dyes :Disperse blue 7) |
- |
1000 |
|
- |
| Cl.4.1 (Table B-3 Sl III)(Allergenic Disperse Dyes :Disperse blue 26) |
- |
1000 |
|
- |
| Cl.4.1 (Table B-3 Sl IV)(Allergenic Disperse Dyes :Disperse blue 102) |
- |
1000 |
|
- |
| Cl.4.1 (Table B-3 Sl V)(Allergenic Disperse Dyes: Disperse brown 1) |
- |
1000 |
|
- |
| Cl.4.1 (Table B-3 Sl VI)(Allergenic Disperse Dyes :Disperse yellow 1) |
- |
1000 |
|
- |
| Cl.4.1 (Table B-3 Sl VII)(Allergenic Disperse Dyes :Disperse yellow 9) |
- |
1000 |
|
- |
| Cl.4.1 (Table B-3 Sl VIII)(Allergenic Disperse Dyes :Disperse yellow 39) |
- |
1000 |
|
- |
| Cl.4.1 (Table B-3 Sl IX)(Allergenic Disperse Dyes :Disperse yellow 49) |
- |
1000 |
|
- |
| Cl.4.1 (Table B-3 Sl X)(Allergenic Disperse Dyes :Disperse orange 1) |
- |
1000 |
|
- |
| Cl.4.1 (Table B-3 Sl XI)(Allergenic Disperse Dyes :Disperse red 11) |
- |
1000 |
|
- |
| Cl.4.1 (Table B-3 Sl XII)(Allergenic Disperse Dyes :Disperse red 17) |
- |
1000 |
|
- |
| Cl.4.1 (Table B-3 Sl XIII)(Allergenic Disperse Dyes :Disperse yellow 7) |
- |
1000 |
|
- |
| Cl.4.1 (Table B-3 Sl XIV)(Allergenic Disperse Dyes :Disperse yellow 56) |
- |
1000 |
|
- |
| Cl.4.1 (Table B-3 Sl XV)(Allergenic Disperse Dyes :Disperse red 151) |
- |
1000 |
|
- |
| Cl.4.1 (Table B-3 Sl XVI)(Allergenic Disperse Dyes :Solvent red 23) |
- |
1000 |
|
- |
| Cl.4.1 (Table B-4 Sl I)(Carcinogenic Disperse Dyes :Navy blue) |
- |
1000 |
|
- |
| Cl.4.1 (Table B-4 Sl II)(Carcinogenic Disperse Dyes: Disperse blue 1) |
- |
1000 |
|
- |
| Cl.4.1 (Table B-4 Sl III)(Carcinogenic Disperse Dyes: Disperse blue 35) |
- |
1000 |
|
- |
| Cl.4.1 (Table B-4 Sl IV)(Carcinogenic Disperse Dyes :Disperse blue 106) |
- |
1000 |
|
- |
| Cl.4.1 (Table B-4 Sl V)(Carcinogenic Disperse Dyes: Disperse blue 124) |
- |
1000 |
|
- |
| Cl.4.1 (Table B-4 Sl VI)(Carcinogenic Disperse Dyes :Disperse yellow 3) |
- |
1000 |
|
- |
| Cl.4.1 (Table B-4 Sl VII)(Carcinogenic Disperse Dyes: Disperse orange 3) |
- |
1000 |
|
- |
| Cl.4.1 (Table B-4 Sl VIII)(Carcinogenic Disperse Dyes :Disperse orange 37/59/76a)) |
- |
1000 |
|
- |
| Cl.4.1 (Table B-4 Sl IX)(Carcinogenic Disperse Dyes :Disperse red 1) |
- |
1000 |
|
- |
| Cl.4.1 (Table B-4 Sl X)(Carcinogenic Disperse Dyes :Basic red 9) |
- |
1000 |
|
- |
| Cl.4.1 (Table B-4 Sl XI)(Carcinogenic Disperse Dyes :Violet 3) |
- |
1000 |
|
- |
| Cl.4.1 (Table B-4 Sl XII)(Carcinogenic Disperse Dyes :Disperse yellow 23) |
- |
1000 |
|
- |
| Cl.4.1 (Table B-1 Sl I)(Aromatic Amines: 4-aminobiphenyl) |
- |
1000 |
|
- |
| Cl.4.1 (Table B-1 Sl II)(Aromatic Amines: Benzidine) |
- |
1000 |
|
- |
| Cl.4.1 (Table B-1 Sl III)(Aromatic Amines: 4-chloro-o-toluidine) |
- |
1000 |
|
- |
| Cl.4.1 (Table B-1 Sl IV)(Aromatic Amines: 2-naphthylamine) |
- |
1000 |
|
- |
| Cl.4.1 (Table B-1 Sl V)(Aromatic Amines :o-aminoazotoluene) |
- |
1000 |
|
- |
| Cl.4.1 (Table B-1 Sl VI)(Aromatic Amines: 2-amino-4-nitrotoluenem) |
- |
1000 |
|
- |
| Cl.4.1 (Table B-1 Sl VII)(Aromatic Amines: p-chloroaniline) |
- |
1000 |
|
- |
| Cl.4.1 (Table B-1 Sl VIII)(Aromatic Amines: 2,4-diaminoanisole) |
- |
1000 |
|
- |
| Cl.4.1 (Table B-1 Sl IX)(Aromatic Amines : 4,4’- diaminodiphenylmethane:) |
- |
1000 |
|
- |
| Cl.4.1 (Table B-1 Sl X)(Aromatic Amines : 3,3’-dichlorobenzidine) |
- |
1000 |
|
- |
| Cl.4.1 (Table B-1 Sl XI)(Aromatic Amines : 3,3’-dimethoxybenzidine) |
- |
1000 |
|
- |
| Cl.4.1 (Table B-1 Sl XII)(Aromatic Amines : 3,3’-dimethylbenzidine) |
- |
1000 |
|
- |
| Cl.4.1 (Table B-1 Sl XIII)(Aromatic Amines: 3,3’-dimethyl-4,4’-diaminodiphenylmethane) |
- |
1000 |
|
- |
| Cl.4.1 (Table B-1 Sl XIV)(Aromatic Amines : p-cresidine) |
- |
1000 |
|
- |
| Cl.4.1 (Table B-1 Sl XV)(Aromatic Amines : 4,4’-methylene-bis(2-chloroaniline):) |
- |
1000 |
|
- |
| Cl.4.1 (Table B-1 Sl XVI)(Aromatic Amines :4,4’-oxydianiline) |
- |
1000 |
|
- |
| Cl.4.1 (Table B-1 Sl XVII)(Aromatic Amines:4,4’-thiodianiline) |
- |
1000 |
|
- |
| Cl.4.1 (Table B-1 Sl XVIII)(Aromatic Amines :o-toluidine:) |
- |
1000 |
|
- |
| Cl.4.1 (Table B-1 Sl XIX)(Aromatic Amines: 2,4-toluylendiamine) |
- |
1000 |
|
- |
| Cl.4.1 (Table B-1 Sl XX)(Aromatic Amines: 2,4,5-trimethylaniline) |
- |
1000 |
|
- |
| Cl.4.1 (Table B-1 Sl XXI)(Aromatic Amines :2,4-dimethylaniline) |
- |
1000 |
|
- |
| Cl.4.1 (Table B-1 Sl XXII)(Aromatic Amines: 2,6-dimethylaniline:) |
- |
1000 |
|
- |
| Cl.4.1 (Table B-1 Sl XXIII)(Aromatic Amines :2-methoxyaniline) |
- |
1000 |
|
- |
| Cl.4.1 (Table B-1 Sl XXIV)(Aromatic Amines :4-aminoazobenzene) |
- |
1000 |
|
- |
| Cl.4.1 (Table B-11)(PCP-TeCP-TriCP polychlorophenols) |
- |
1000 |
|
- |
|
- |
- - |
| 1445 |
JBS TESTING SOLUTIONS PVT LTD (27), JALANDHAR
| 9164606
| IS 19315 (2025) |
Ball Valves for Water Works Purposes - Specification |
8 mm and above |
19850 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| As per Clause 3(TERMS AND DEFINITION) |
- |
19850 |
|
9850 (For mechanical test) +
10,000 for chemical (additional sample will be provided where applicable) , Size: 8mm and above |
| As per Clause 3.1(Ambient Temperature) |
- |
19850 |
|
9850 (For mechanical test) +
10,000 for chemical (additional sample will be provided where applicable) |
| As per Clause 3.2(Cold Working Pressure (CWP)) |
- |
19850 |
|
9850 (For mechanical test) +
10,000 for chemical (additional sample will be provided where applicable) |
| Cl 3.3(DN) |
- |
19850 |
|
9850 (For mechanical test) +
10,000 for chemical (additional sample will be provided where applicable) |
| Cl 3.4(End-to-End Dimension) |
- |
19850 |
|
9850 (For mechanical test) +
10,000 for chemical (additional sample will be provided where applicable) |
| Cl 3.5(Face-to-Face Dimension) |
- |
19850 |
|
9850 (For mechanical test) +
10,000 for chemical (additional sample will be provided where applicable) |
| Cl 3.6(Full Bore Valve) |
- |
19850 |
|
9850 (For mechanical test) +
10,000 for chemical (additional sample will be provided where applicable) |
| Cl 3.7(Operator) |
- |
19850 |
|
9850 (For mechanical test) +
10,000 for chemical (additional sample will be provided where applicable) |
| Cl 3.8(PN or Class) |
- |
19850 |
|
9850 (For mechanical test) +
10,000 for chemical (additional sample will be provided where applicable) |
| Cl 3.9(Reduce Bore Valve) |
- |
19850 |
|
9850 (For mechanical test) +
10,000 for chemical (additional sample will be provided where applicable) |
| Cl 3.10(Trim) |
- |
19850 |
|
9850 (For mechanical test) +
10,000 for chemical (additional sample will be provided where applicable) |
| Cl 4(DESIGN) |
- |
19850 |
|
9850 (For mechanical test) +
10,000 for chemical (additional sample will be provided where applicable) |
| Cl 4.1(Ball Valve Construction) |
- |
19850 |
|
9850 (For mechanical test) +
10,000 for chemical (additional sample will be provided where applicable) |
| Cl 4.2(Nominal Sizes) |
- |
19850 |
|
9850 (For mechanical test) +
10,000 for chemical (additional sample will be provided where applicable) |
| Cl 4.3(Rating) |
- |
19850 |
|
9850 (For mechanical test) +
10,000 for chemical (additional sample will be provided where applicable) |
| Cl 4.4(Valve Bore Dimensions) |
- |
19850 |
|
9850 (For mechanical test) +
10,000 for chemical (additional sample will be provided where applicable) |
| Cl 4.5(Face-to-Face and End-to-End Dimensions) |
- |
19850 |
|
9850 (For mechanical test) +
10,000 for chemical (additional sample will be provided where applicable) |
| Cl 4.6(Valve Ends) |
- |
19850 |
|
9850 (For mechanical test) +
10,000 for chemical (additional sample will be provided where applicable) |
| Cl 4.6.1(Flanged End) |
- |
19850 |
|
9850 (For mechanical test) +
10,000 for chemical (additional sample will be provided where applicable) |
| Cl 4.6.2(Socket Weld Ends for Stainless Steel Materials) |
- |
19850 |
|
9850 (For mechanical test) +
10,000 for chemical (additional sample will be provided where applicable) |
| Cl 4.6.3(Solder Ends for Copper Alloy Materials) |
- |
19850 |
|
9850 (For mechanical test) +
10,000 for chemical (additional sample will be provided where applicable) |
| Cl 4.6.4(Screwed Ends) |
- |
19850 |
|
9850 (For mechanical test) +
10,000 for chemical (additional sample will be provided where applicable) |
| Cl 4.6.4.1(Screwed end for copper alloy materials) |
- |
19850 |
|
9850 (For mechanical test) +
10,000 for chemical (additional sample will be provided where applicable) |
| Cl 4.6.4.2(Screwed end for stainless steel materials) |
- |
19850 |
|
9850 (For mechanical test) +
10,000 for chemical (additional sample will be provided where applicable) |
| Cl 4.6.5(Crimping Ends for Copper Alloy materials) |
- |
19850 |
|
9850 (For mechanical test) +
10,000 for chemical (additional sample will be provided where applicable) |
| Cl 4.7(Design) |
- |
19850 |
|
9850 (For mechanical test) +
10,000 for chemical (additional sample will be provided where applicable) |
| Cl 4.7.1(General) |
- |
19850 |
|
9850 (For mechanical test) +
10,000 for chemical (additional sample will be provided where applicable) |
| Cl 4.7.1.2("Body shell thickness for copper alloy
materials ") |
- |
19850 |
|
9850 (For mechanical test) +
10,000 for chemical (additional sample will be provided where applicable) |
| Cl 4.7.1.3(Joint) |
- |
19850 |
|
9850 (For mechanical test) +
10,000 for chemical (additional sample will be provided where applicable) |
| Cl 4.7.1.5(End connections) |
- |
19850 |
|
9850 (For mechanical test) +
10,000 for chemical (additional sample will be provided where applicable) |
| Cl 4.7.1.6(Stems) |
- |
19850 |
|
9850 (For mechanical test) +
10,000 for chemical (additional sample will be provided where applicable) |
| Cl 4.7.1.8(Stem packing) |
- |
19850 |
|
9850 (For mechanical test) +
10,000 for chemical (additional sample will be provided where applicable) |
| Cl 4.7.1.9(Corrosion resistant coating) |
- |
19850 |
|
9850 (For mechanical test) +
10,000 for chemical (additional sample will be provided where applicable) |
| Cl 4.7.2(Body Shell Thickness for Steel Valves) |
- |
19850 |
|
9850 (For mechanical test) +
10,000 for chemical (additional sample will be provided where applicable) |
| Cl 4.7.3(Body Shell Thickness) |
- |
19850 |
|
9850 (For mechanical test) +
10,000 for chemical (additional sample will be provided where applicable) |
| Cl 4.7.4(Bolted Body Joint) |
- |
19850 |
|
9850 (For mechanical test) +
10,000 for chemical (additional sample will be provided where applicable) |
| Cl 4.7.5(Bolted Bonnet or Cover Joint) |
- |
19850 |
|
9850 (For mechanical test) +
10,000 for chemical (additional sample will be provided where applicable) |
| Cl 5(VALVE OPERATION) |
- |
19850 |
|
9850 (For mechanical test) +
10,000 for chemical (additional sample will be provided where applicable) |
| Cl 6(MATERIALS OF CONSTRUCTION) |
- |
19850 |
|
9850 (For mechanical test) +
10,000 for chemical (additional sample will be provided where applicable) |
| Cl 7(PERFORMANCE REQUIREMENTS) |
- |
19850 |
|
9850 (For mechanical test) +
10,000 for chemical (additional sample will be provided where applicable) |
| Cl 7.2(Pressure Tests for Steel Valves) |
- |
19850 |
|
9850 (For mechanical test) +
10,000 for chemical (additional sample will be provided where applicable) |
| Cl 7.2.1(Shell Test (HYD)) |
- |
19850 |
|
9850 (For mechanical test) +
10,000 for chemical (additional sample will be provided where applicable) |
| Cl 7.2.2(Closure Test (HYD)) |
- |
19850 |
|
9850 (For mechanical test) +
10,000 for chemical (additional sample will be provided where applicable) |
| Cl 7.2.3(Closure Test (Gas)) |
- |
19850 |
|
9850 (For mechanical test) +
10,000 for chemical (additional sample will be provided where applicable) |
| Cl 7.2.4(Test Duration) |
- |
19850 |
|
9850 (For mechanical test) +
10,000 for chemical (additional sample will be provided where applicable) |
| Cl 7.3(Pressure Tests for Copper Alloy Valves) |
- |
19850 |
|
9850 (For mechanical test) +
10,000 for chemical (additional sample will be provided where applicable) |
| Cl 7.3.1(Shell Test) |
- |
19850 |
|
9850 (For mechanical test) +
10,000 for chemical (additional sample will be provided where applicable) |
| Cl 7.3.2(Closure Test) |
- |
19850 |
|
9850 (For mechanical test) +
10,000 for chemical (additional sample will be provided where applicable) |
| Cl 7.4(Test Fluid) |
- |
19850 |
|
9850 (For mechanical test) +
10,000 for chemical (additional sample will be provided where applicable) |
| Cl 7.5(Test Gauges) |
- |
19850 |
|
9850 (For mechanical test) +
10,000 for chemical (additional sample will be provided where applicable) |
| Cl 8(SAMPLING AND TESTING) |
- |
19850 |
|
9850 (For mechanical test) +
10,000 for chemical (additional sample will be provided where applicable) |
| Cl 8.2(Factory Production Control) |
- |
19850 |
|
9850 (For mechanical test) +
10,000 for chemical (additional sample will be provided where applicable) |
| Cl 9(PACKAGING) |
- |
19850 |
|
9850 (For mechanical test) +
10,000 for chemical (additional sample will be provided where applicable) |
| Cl 10(MARKING) |
- |
19850 |
|
9850 (For mechanical test) +
10,000 for chemical (additional sample will be provided where applicable) |
| Cl 10.1(Legibility) |
- |
19850 |
|
9850 (For mechanical test) +
10,000 for chemical (additional sample will be provided where applicable) |
| Cl 10.2(Body Marking) |
- |
19850 |
|
9850 (For mechanical test) +
10,000 for chemical (additional sample will be provided where applicable) |
| Cl 10.3(Identification Plate) |
- |
19850 |
|
9850 (For mechanical test) +
10,000 for chemical (additional sample will be provided where applicable) |
|
- |
- - |
| 1446 |
Samridhi Test House Pvt. Ltd.
| 8184706
| IS 302 : Part 2 : Sec 24 (1994) |
Safety of household and similar electrical appliances: Part 2 particular requirements: Sec 24 refrigerators, food - Freezers and ice - Makers |
All Grade / Type / Size / Designation |
49800 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 32(Radiation, toxicity and similar hazards) |
- |
300 |
|
- |
| 31(Resistance to rusting) |
- |
300 |
|
- |
| 30.3(Resistance to heat and fire) |
- |
300 |
|
- |
| 30.2(Resistance to heat and fire) |
- |
300 |
|
- |
| 30.1(Resistance to heat and fire) |
- |
300 |
|
- |
| 30.1(Resistance to heat and fire) |
- |
300 |
|
- |
| 29.2 & 29.3(Clearances, creepage distances ) |
- |
300 |
|
- |
| 29.1 and table 2(creepage and Clearances distances ) |
- |
300 |
|
- |
| 28.2 to 28.4(Screws and connections) |
- |
100 |
|
- |
| 28.1, Table No.-14(Screws and connections) |
- |
200 |
|
- |
| 27.5(Provision for earthing) |
- |
300 |
|
- |
| 27.1 to 27.4(Provision for earthing) |
- |
300 |
|
- |
| 26.10 & 26.13(Terminals for external conductors) |
- |
300 |
|
- |
| 26.9(Terminals for external conductors) |
- |
300 |
|
- |
| 26.1 to 26.8(Terminals for external conductors) |
- |
300 |
|
- |
| 25.7 to 25.13(Supply connection and external flexible cords) |
- |
300 |
|
- |
| 25.6(Supply connection and external flexible cords) |
- |
300 |
|
- |
| 25.4(Supply connection and external flexible cords) |
- |
300 |
|
- |
| 25.4(Supply connection and external flexible cords) |
- |
300 |
|
- |
| 25.3(Supply connection and external flexible cords) |
- |
300 |
|
- |
| 25.2(Supply connection and external flexible cords) |
- |
300 |
|
- |
| 25.1(Supply connection and external flexible cords) |
- |
300 |
|
- |
| 24.2 ,24.3,24.5 & 24.6(Components) |
- |
300 |
|
- |
| 24.1(Components) |
- |
300 |
|
- |
| 23.5 to 23.8(Internal wiring) |
- |
300 |
|
- |
| 23.4(Internal wiring) |
- |
300 |
|
- |
| 23.3(Internal wiring) |
- |
300 |
|
- |
| 23.1 & 23.2(Internal wiring) |
- |
300 |
|
- |
| 22.101 to 22.103(Constructions) |
- |
300 |
|
- |
| 22.13 to 22.33(Constructions) |
- |
300 |
|
- |
| 22.12(Constructions) |
- |
300 |
|
- |
| 22.11(Constructions) |
- |
300 |
|
- |
| 22.7 to 22.10(Constructions) |
- |
300 |
|
- |
| 22.6(Constructions) |
- |
300 |
|
- |
| 22.5(Constructions) |
- |
300 |
|
- |
| 22.4(Constructions) |
- |
300 |
|
- |
| 22.3(Constructions) |
- |
300 |
|
- |
| 22.2(Constructions) |
- |
300 |
|
- |
| 22.1(Constructions) |
- |
300 |
|
- |
| 21.2(MECHANICAL STRENGTH) |
- |
300 |
|
- |
| 21.1(MECHANICAL STRENGTH) |
- |
300 |
|
- |
| 20.2(Stability and mechanical hazards) |
- |
300 |
|
- |
| 20.1(Stability and mechanical hazards) |
- |
300 |
|
- |
| 19.103(ABNORMAL OPERATION) |
- |
300 |
|
- |
| 19.102(ABNORMAL OPERATION) |
- |
300 |
|
- |
| 19.101(ABNORMAL OPERATION) |
- |
300 |
|
- |
| 19.11(ABNORMAL OPERATION) |
- |
300 |
|
- |
| 19.9(ABNORMAL OPERATION) |
- |
300 |
|
- |
| 19.7(ABNORMAL OPERATION) |
- |
300 |
|
- |
| 19(ABNORMAL OPERATION) |
- |
300 |
|
- |
| 17(Over load Protection ) |
- |
300 |
|
- |
| 16.4(INSULATION RESISTANCE AND
ELECTRIC STRENGTH ( After the Humidity
Treatment )) |
- |
300 |
|
- |
| 16.3 & table(INSULATION RESISTANCE AND
ELECTRIC STRENGTH ( After the Humidity
Treatment )) |
- |
300 |
|
- |
| 16.2(INSULATION RESISTANCE AND
ELECTRIC STRENGTH ( After the Humidity
Treatment )) |
- |
300 |
|
- |
| 16 & 16.1(INSULATION RESISTANCE AND
ELECTRIC STRENGTH ( After the Humidity
Treatment )) |
- |
300 |
|
- |
| 15.103(Moisture resistance) |
- |
300 |
|
- |
| 15.102(Moisture resistance) |
- |
300 |
|
- |
| 15.101(Moisture resistance) |
- |
300 |
|
- |
| 15.4(Moisture resistance) |
- |
300 |
|
- |
| 15.3(Moisture resistance) |
- |
300 |
|
- |
| 15.2(Moisture resistance) |
- |
300 |
|
- |
| 15(Moisture resistance) |
- |
300 |
|
- |
| 14( RADIO AND TELEVISION
INTERFERENCE SUPPRESSION
) |
- |
300 |
|
- |
| 13(ELECTRICAL INSULATION AND
LEAKAGE CURRENT AT OPERATING
TEMPERATURE) |
- |
300 |
|
- |
| 12,12.1,12.2 & 12.3(Heating) |
- |
300 |
|
- |
| 11.103(TEMPERATURE RISE) |
- |
300 |
|
- |
| 11.102(TEMPERATURE RISE) |
- |
300 |
|
- |
| 11.101(TEMPERATURE RISE) |
- |
300 |
|
- |
| 11.1(TEMPERATURE RISE) |
- |
300 |
|
- |
| 11.8(TEMPERATURE RISE) |
- |
300 |
|
- |
| 11.7(TEMPERATURE RISE) |
- |
300 |
|
- |
| 11.6(TEMPERATURE RISE) |
- |
300 |
|
- |
| 11.5(TEMPERATURE RISE) |
- |
300 |
|
- |
| 11.4(TEMPERATURE RISE) |
- |
300 |
|
- |
| 11.2(TEMPERATURE RISE) |
- |
300 |
|
- |
| 11(TEMPERATURE RISE) |
- |
300 |
|
- |
| 10.1,10.2
10.101,10.102( Input and Current) |
- |
300 |
|
- |
| 9.2(Startability Test) |
- |
300 |
|
- |
| 9.1(Startability Test) |
- |
300 |
|
- |
| 9(Starting of motor operated Appliances) |
- |
300 |
|
- |
| 8.1.5(Protection against access to live parts) |
- |
300 |
|
- |
| 8.1.4(Protection against access to live parts) |
- |
300 |
|
- |
| 8.1.3(Protection against access to live parts) |
- |
300 |
|
- |
| 8.1.2(Protection against access to live parts) |
- |
300 |
|
- |
| 8.1, 8.1.1 & 8.2(Protection against access to live parts) |
- |
300 |
|
- |
| 7.1 , 7.12, 7.14,7.15(Marking) |
- |
300 |
|
- |
| 32(Radiation, toxicity and similar hazards) |
- |
300 |
|
- |
| 31(Resistance to rusting) |
- |
300 |
|
- |
| 30.3(Resistance to heat and fire) |
- |
300 |
|
- |
| 30.2(Resistance to heat and fire) |
- |
300 |
|
- |
| 30.1(Resistance to heat and fire) |
- |
300 |
|
- |
| 30.1(Resistance to heat and fire) |
- |
300 |
|
- |
| 29.2 & 29.3(Clearances, creepage distances ) |
- |
300 |
|
- |
| 29.1 and table 2(creepage and Clearances distances ) |
- |
300 |
|
- |
| 28.2 to 28.4(Screws and connections) |
- |
300 |
|
- |
| 28.1, Table No.-14(Screws and connections) |
- |
300 |
|
- |
| 27.5(Provision for earthing) |
- |
300 |
|
- |
| 27.1 to 27.4(Provision for earthing) |
- |
300 |
|
- |
| 26.10 & 26.13(Terminals for external conductors) |
- |
300 |
|
- |
| 26.9(Terminals for external conductors) |
- |
300 |
|
- |
| 26.1 to 26.8(Terminals for external conductors) |
- |
300 |
|
- |
| 25.7 to 25.13(Supply connection and external flexible cords) |
- |
300 |
|
- |
| 25.6(Supply connection and external flexible cords) |
- |
300 |
|
- |
| 25.4(Supply connection and external flexible cords) |
- |
300 |
|
- |
| 25.4(Supply connection and external flexible cords) |
- |
300 |
|
- |
| 25.3(Supply connection and external flexible cords) |
- |
300 |
|
- |
| 25.2(Supply connection and external flexible cords) |
- |
300 |
|
- |
| 25.1(Supply connection and external flexible cords) |
- |
300 |
|
- |
| 24.2 ,24.3,24.5 & 24.6(Components) |
- |
300 |
|
- |
| 24.1(Components) |
- |
300 |
|
- |
| 23.5 to 23.8(Internal wiring) |
- |
300 |
|
- |
| 23.4(Internal wiring) |
- |
300 |
|
- |
| 23.3(Internal wiring) |
- |
300 |
|
- |
| 23.1 & 23.2(Internal wiring) |
- |
300 |
|
- |
| 22.101 to 22.103(Constructions) |
- |
300 |
|
- |
| 22.13 to 22.33(Constructions) |
- |
300 |
|
- |
| 22.12(Constructions) |
- |
300 |
|
- |
| 22.11(Constructions) |
- |
300 |
|
- |
| 22.7 to 22.10(Constructions) |
- |
300 |
|
- |
| 22.6(Constructions) |
- |
300 |
|
- |
| 22.5(Constructions) |
- |
300 |
|
- |
| 22.4(Constructions) |
- |
300 |
|
- |
| 22.3(Constructions) |
- |
300 |
|
- |
| 22.2(Constructions) |
- |
300 |
|
- |
| 22.1(Constructions) |
- |
300 |
|
- |
| 21.2(MECHANICAL STRENGTH) |
- |
100 |
|
- |
| 21.1(MECHANICAL STRENGTH) |
- |
100 |
|
- |
| 20.2(Stability and mechanical hazards) |
- |
100 |
|
- |
| 20.1(Stability and mechanical hazards) |
- |
100 |
|
- |
| 19.103(ABNORMAL OPERATION) |
- |
300 |
|
- |
| 19.102(ABNORMAL OPERATION) |
- |
300 |
|
- |
| 19.101(ABNORMAL OPERATION) |
- |
300 |
|
- |
| 19.11(ABNORMAL OPERATION) |
- |
300 |
|
- |
| 19.9(ABNORMAL OPERATION) |
- |
300 |
|
- |
| 19.7(ABNORMAL OPERATION) |
- |
300 |
|
- |
| 19(ABNORMAL OPERATION) |
- |
300 |
|
- |
| 17(Over load Protection ) |
- |
300 |
|
- |
| 16.4(INSULATION RESISTANCE AND
ELECTRIC STRENGTH ( After the Humidity
Treatment )) |
- |
200 |
|
- |
| 16.3 & table(INSULATION RESISTANCE AND
ELECTRIC STRENGTH ( After the Humidity
Treatment )) |
- |
200 |
|
- |
| 16.2(INSULATION RESISTANCE AND
ELECTRIC STRENGTH ( After the Humidity
Treatment )) |
- |
200 |
|
- |
| 16 & 16.1(INSULATION RESISTANCE AND
ELECTRIC STRENGTH ( After the Humidity
Treatment )) |
- |
200 |
|
- |
| 15.103(Moisture resistance) |
- |
300 |
|
- |
| 15.102(Moisture resistance) |
- |
300 |
|
- |
| 15.101(Moisture resistance) |
- |
300 |
|
- |
| 15.4(Moisture resistance) |
- |
300 |
|
- |
| 15.3(Moisture resistance) |
- |
300 |
|
- |
| 15.2(Moisture resistance) |
- |
300 |
|
- |
| 15(Moisture resistance) |
- |
300 |
|
- |
| 14( RADIO AND TELEVISION
INTERFERENCE SUPPRESSION
) |
- |
100 |
|
- |
| 13(ELECTRICAL INSULATION AND
LEAKAGE CURRENT AT OPERATING
TEMPERATURE) |
- |
200 |
|
- |
| 12,12.1,12.2 & 12.3(Heating) |
- |
300 |
|
- |
| 11.103(TEMPERATURE RISE) |
- |
300 |
|
- |
| 11.102(TEMPERATURE RISE) |
- |
300 |
|
- |
| 11.101(TEMPERATURE RISE) |
- |
300 |
|
- |
| 11.1(TEMPERATURE RISE) |
- |
300 |
|
- |
| 11.8(TEMPERATURE RISE) |
- |
300 |
|
- |
| 11.7(TEMPERATURE RISE) |
- |
300 |
|
- |
| 11.6(TEMPERATURE RISE) |
- |
300 |
|
- |
| 11.5(TEMPERATURE RISE) |
- |
300 |
|
- |
| 11.4(TEMPERATURE RISE) |
- |
300 |
|
- |
| 11.2(TEMPERATURE RISE) |
- |
300 |
|
- |
| 11(TEMPERATURE RISE) |
- |
300 |
|
- |
| 10.1,10.2
10.101,10.102( Input and Current) |
- |
300 |
|
- |
| 9.2(Startability Test) |
- |
300 |
|
- |
| 9.1(Startability Test) |
- |
300 |
|
- |
| 9(Starting of motor operated Appliances) |
- |
300 |
|
- |
| 8.1.5(Protection against access to live parts) |
- |
300 |
|
- |
| 8.1.4(Protection against access to live parts) |
- |
300 |
|
- |
| 8.1.3(Protection against access to live parts) |
- |
300 |
|
- |
| 8.1.2(Protection against access to live parts) |
- |
300 |
|
- |
| 8.1, 8.1.1 & 8.2(Protection against access to live parts) |
- |
300 |
|
- |
| 7.1 , 7.12, 7.14,7.15(Marking) |
- |
100 |
|
- |
| 19.11.4.1(Electrostatic discharges) |
- |
0 |
|
- |
| 19.11.4.2(Radiated fields) |
- |
0 |
|
- |
| 19.11.4.3(Fast transient bursts) |
- |
0 |
|
- |
| 19.11.4.4(Surge immunity test) |
- |
0 |
|
- |
| 19.11.4.5(Immunity to conducted discharges) |
- |
0 |
|
- |
| 19.11.4.6(Class 3 Voltage dips and interruptions) |
- |
0 |
|
- |
| 19.11.4.7(Harmonics) |
- |
0 |
|
- |
| 6(Classifications) |
- |
100 |
|
- |
| 6(Classifications) |
- |
100 |
|
- |
|
- |
- Included w.e.f 31.12.2025
Exclusion: Cl 19.11.4.1-19.11.4.7(EMI/EMC) |
| 1447 |
AANKAN CALIBRATION AND TESTING CENTRE LLP, DANTLI
| 7184406
| IS 12818 (2010) |
Unplasticized polyvinyl chloride (Pvc - U) screen and casing pipes for bore/tubewells - Specification (Second Revision) |
- |
15000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 9.6(Vicat Softening Temperature
IS 12235 (Part 2).) |
- |
2000 |
|
- |
| 9.5(Tensile Strength
IS 12235(Part 13)) |
- |
2500 |
|
- |
| 9.4 and Table 14(Resistance to External Blows at 0 ?C
IS 12235 (Part 9)) |
- |
2000 |
|
- |
| 9.3(Density
IS 12235 (Part 14)) |
- |
750 |
|
- |
| 9.2(Internal Diameter) |
- |
500 |
|
- |
| 9.1( Visual Appearance) |
- |
250 |
|
- |
| 9.1(Visual Appearance) |
- |
0 |
|
- |
| 8.4.1 and Table 13
Fig 3B & 4B(Dimensions of sealing elements) |
- |
500 |
|
- |
| 8.4.1 and Table 13
Fig 3B & 4B(Dimensions of sealing elements) |
- |
0 |
|
- |
| 8.4.1 and Table 13
Fig 3B & 4B(Dimensions of sealing elements) |
- |
0 |
|
- |
| 8.4.1 and Table 13
Fig 3B & 4B(Dimensions of sealing elements) |
- |
0 |
|
- |
| 8.4.1 and Table 13
Fig 3B & 4B(Dimensions of sealing elements) |
- |
0 |
|
- |
| 8.4.1 and Table 13
Fig 3B & 4B(Dimensions of sealing elements) |
- |
0 |
|
- |
| 8.4.1 and Table 13
Fig 3B & 4B(Dimensions of sealing elements) |
- |
0 |
|
- |
| 8.4(Sealing rings - Hardness) |
- |
500 |
|
- |
| 8.1 to 8.3 and Table 11 &12
Fig 3A & 4A(THREADING OF SCREEN ANDCASING PIPES.
IS 554.) |
- |
500 |
|
- |
| 8.1 to 8.3 and Table 11 &12
Fig 3A & 4A(THREADING OF SCREEN ANDCASING PIPES.
IS 554.) |
- |
0 |
|
- |
| 7.5 and Table 10
Fig 2A & 2B(Approximate Free Passage Area, in Percent (Mean Value) for Width of Slot (w)) |
- |
250 |
|
- |
| 7.5 and Table 10
Fig 2A & 2B(Minimum number of slots on the circumference of the cross-section.) |
- |
250 |
|
- |
| 7.5 and Table 10
Fig 2A & 2B(Summation of slot lengths over internal circumference of the cross- section.) |
- |
250 |
|
- |
| 7.4 Table 8 & 9 Fig 1(Segmental length for Spigot (average of 4.0)) |
- |
500 |
|
- |
| 7.4 Table 8 & 9 Fig 1(Segmental length,mm for socket (average of 4.0)) |
- |
500 |
|
- |
| 7.4 Table 8 & 9
Fig 1(Segmental length, l3) |
- |
500 |
|
- |
| 7.4 Table 8 & 9
Fig 1(Effective length, l2) |
- |
500 |
|
- |
| 7.3.2(Rib height) |
- |
250 |
|
- |
| 7.3.1(No.of Ribs) |
- |
250 |
|
- |
| 7.2 and Table 5, 6 & 7
Fig 1B(Wall thickness, Max) |
- |
250 |
|
- |
| 7.2 and Table 5, 6 & 7
Fig 1B(Wall thickness, Min) |
- |
250 |
|
- |
| 7.1, 7.2 and Table 5, 6 & 7 Fig 1B(Mean outside dia over connection,mm (Take 4 reading and maximum valu reported)) |
- |
250 |
|
- |
| 7.1, 7.2 and Table 5, 6 & 7 Fig 1B(Outer Diameter at any point, Max) |
- |
250 |
|
- |
| 7.1, 7.2 and Table 5, 6 & 7 Fig 1B(Outer Diameter at any point , Min) |
- |
250 |
|
- |
| 7.2 and Table 5, 6 & 7
Fig 1B(Mean Outer Diameter of Pipe , Max) |
- |
250 |
|
- |
| 7.2 and Table 5, 6 & 7
Fig 1B(Mean Outer Diameter of Pipe, Min) |
- |
250 |
|
- |
| 7.2 and Table 5, 6 & 7
Fig 1B(Nominal Diameter) |
- |
250 |
|
- |
| 7.2 and Table 5, 6 & 7
Fig 1B(DIMENSIONS - Casing Pipes) |
- |
500 |
|
- |
| 7.1 and Table 1, 2, 3, & 4
Fig 1A & 1B(Wall thickness) |
- |
250 |
|
- |
| 7.1 and Table 1, 2, 3, & 4
Fig 1A & 1B(Mean Outer Diameter over Connection) |
- |
250 |
|
- |
| 7.1 and Table 1, 2, 3, & 4
Fig 1A & 1B(Outer Diameter at any point ) |
- |
250 |
|
- |
| 7.1 and Table 1, 2, 3, & 4
Fig 1A & 1B(Mean Outer Diameter of Pipe) |
- |
250 |
|
- |
| 7.1 and Table 1, 2, 3, & 4
Fig 1A & 1B(Nominal Diameter) |
- |
250 |
|
- |
| 4.1.2 (Ref. Cl 11 of IS 4669)(Composition -Sulphated ash content ) |
- |
0 |
|
- |
| 4.1.2 (Ref. Cl 5.1. of IS 4669)(Composition - Loss on heating ) |
- |
0 |
|
- |
| 4.1.1 (Ref. 3.4.1. of IS 10151)(Composition - The monomer content (VCM content) in the
resin - Annex A ofIS 10151) |
- |
5000 |
|
- |
| 5(COLOUR) |
- |
250 |
|
- |
| 8.4(Sealing elements
a. Elastomeric material
b. Shore A hardness of sealing Elements
) |
- |
0 |
|
- |
| 8.4(Width b) |
- |
0 |
|
- |
| 8.3.1
&
8.3.2
(Threading of casing pipe (from 100 to 200 DN Table – 11 & Fig. 3A) & (from 250 to 400 DN Table – 12 & Fig. 4A)
Outside diameter
d1(+0, -0.3)
d2
d3
D1 (+0.3, -0)
D2
D4
D5 (+0.3, -0)
Z
h3 (+0, -0.1)
H4 (+0, -0.1)
) |
- |
500 |
|
- |
| 8.2(Threading of casing pipe As per IS 554 (from 40 to 80mm DN)
Number of threads in 25.4mm
Pitch (P)
Height of thread (h)
Major (Gauge Diameter) d
Pitch(d2)
Minor (d1)
External Thread gauge length
Nominal
No. of turns of thread
max
min
) |
- |
500 |
|
- |
| 7.5.1
7.5.2
(Slot Dimension (Table 10) Fig 2A & 2B
a. Minimum number of slot on the circumference
b. Σa±5%
c. Mean value of approximate free passage area (%) for width of slot (w)
d. Tolerance on width of slot (w)
e. Width of material between slot (b)) |
- |
0 |
|
- |
| 5.0(Colour of Pipes) |
- |
0 |
|
- |
| 9.7(Effect on Water
a) Lead (first extraction)
b) Lead (Third extraction)
c) Dialkyl Tin C4 & higher homologues measured as Tin (Third extraction)
d) Cadmium (All three extracts)
e) Mercury (All three extracts)
f) Other Toxic Substances
) |
- |
5000 |
|
- |
| 4.1.2(K-Value as per IS-4669) |
- |
2000 |
|
Extra charge For Raw-material Testing |
| 4.1.1
(VCM Content as per IS 10151 (Annex A)) |
- |
0 |
|
Extra charge For Raw-material Testing |
| 7.1(Screen Pipes) |
- |
500 |
|
- |
| 11(Marking) |
- |
2000 |
|
- |
| 5.1(Materials) |
- |
0 |
|
- |
| 8(Packing) |
- |
0 |
|
- |
| 4.1.3(Cross Chain Length) |
- |
0 |
|
- |
| 7.2(Link Twisted (Cross chain)) |
- |
0 |
|
- |
| 7.3(The Basic chains) |
- |
0 |
|
- |
| 7.9(Case Depth) |
- |
0 |
|
- |
| 8(Marking) |
- |
0 |
|
- |
| Cl 9.7(Effect on Water Lead (first extraction)) |
- |
0 |
|
- |
| Cl 9.7(Effect on Water Lead (third extraction)) |
- |
0 |
|
- |
| Cl 9.7(Effect on Water Dialkyl tin C4 and higher homologues(measuredas tin )(third extraction )) |
- |
0 |
|
- |
| Cl 9.7(Effect on Water Cadmium (mean of first extraction, second extraction and third extraction)) |
- |
0 |
|
- |
| Cl 9.7(Effect on Water Mercury (mean of first extraction, second extraction and third extraction)) |
- |
0 |
|
- |
| CL 7.1,7.2(Mean out side Diameter (For less than or equal to 40 mm- Average of 8 , For higher diameters up to 110 mm average of 6)) |
- |
250 |
|
- |
|
17 Mar, 2028 |
- Included w.e.f. 24.12.2025 |
| 1448 |
BIS, Central Laboratory (CL)
| None
| IS 4990 (2024) |
PLYWOOD FOR CONCRETE SHUTTERING WORKS SPECIFICATION (Fourth Revision) |
All |
₹ 16, 700/- View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl-5.1 (Timber) |
- |
|
|
|
| Cl-7.1 (Dimensions -length) |
- |
|
|
|
|
- |
- - |
| 1449 |
ACE TEST HOUSE PRIVATE LIMITED (8161906), NEW DELHI
| 8161906
| IS 710 (2024) |
MARINE PLYWOOD - SPECIFICATION (Third Revision) |
Grade-BWP |
13500 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl-4.1(Timber) |
- |
0 |
|
- |
| Cl-4.2(Adhesive) |
- |
500 |
|
- |
| Cl-5.1(Veneers) |
- |
0 |
|
- |
| Cl-5.2.1(Glueing) |
- |
0 |
|
- |
| Cl -5.2.2(Thickness of Veneers) |
- |
0 |
|
- |
| Cl - 5.2.3.1(Joint in Veneers) |
- |
0 |
|
- |
| Cl - 5.2.3.2(Edge joints) |
- |
0 |
|
- |
| Cl - 5.2.3.3(End joints) |
- |
0 |
|
- |
| Cl - 5.2.3.4(Scarf joints) |
- |
0 |
|
- |
| Cl - 5.2.4(Grain Direction) |
- |
0 |
|
- |
| Cl-5.4(Moisture Content) |
- |
300 |
|
- |
| Cl-6.1(Dimensions (length)) |
- |
100 |
|
- |
| Cl-6.2(Thickness) |
- |
100 |
|
- |
| Cl-6.3(Squareness) |
- |
100 |
|
- |
| Cl-7.1, 7.2, 7.3, 7.4, 7.5 & 7.6(Workmanship and finish) |
- |
100 |
|
- |
| Cl-9.3(Moisture Content) |
- |
0 |
|
- |
| Cl-9.4.2(Glue Adhesion in Dry State- Adhesion of Plies) |
- |
150 |
|
- |
| Cl-9.4.1(Glue Adhesion in Dry State- Glue Shear Strength -Average) |
- |
150 |
|
- |
| Cl-9.5.1.1(Glue Adhesion in Water Resistance - Glue Shear Strength -Average) |
- |
150 |
|
- |
| Cl-9.5.1.2(Water Resistance Test-Adhesion of plies) |
- |
150 |
|
- |
| Cl-9.5.2(Water Resistance Test) |
- |
150 |
|
- |
| Cl-9.6(Tensile Strength-Along the grain) |
- |
150 |
|
- |
| Cl-9.7(Mycological Test -Adhesion) |
- |
200 |
|
- |
| Cl-9.8, Table-2(Static Bending Strength - Modulus of Elasticity - Along the Face Grain - Average) |
- |
150 |
|
- |
| Cl-9.8, Table-2(Static Bending Strength - Modulus of Elasticity - Along the Face Grain - Minimum Individual) |
- |
150 |
|
- |
| Cl-9.9, Table-3 (i) a((Modulus of Elasticity: Across the Face Grain: Average) Wet Bending) |
- |
150 |
|
- |
| Cl-9.9, Table-3 (i) b((Modulus of Elasticity: Across the Face Grain: Minimum Individual) Wet Bending) |
- |
150 |
|
- |
| Cl-9.4.2(Adhesion of Plies) |
- |
100 |
|
- |
| 5.1.1(Defects in veneers) |
- |
100 |
|
- |
| Cl-9.8, Table-2(Static Bending Strength - Modulus of Elasticity - Across the Face Grain - Average) |
- |
150 |
|
- |
| Cl-9.8, Table-2(Static Bending Strength - Modulus of Elasticity - Across the Face Grain - Minimum Individual) |
- |
150 |
|
- |
| Cl-9.9, Table-3 (ii) a((Modulus of Rupture: Across the Face Grain: Average) Wet Bending) |
- |
150 |
|
- |
| Cl-9.9, Table-3 (ii) b((Modulus of Rupture: Across the Face Grain: Minimum Individual) Wet Bending) |
- |
150 |
|
- |
| Cl-6.1(Dimensions (width)) |
- |
100 |
|
- |
| Cl-8.3(Edge Straightness) |
- |
100 |
|
- |
| Cl-9.4.1(Glue Adhesion in Dry State- Glue Shear Strength –Minimum Individual) |
- |
150 |
|
- |
| Cl-9.5.1.1(Glue Adhesion in Water Resistance - Glue Shear Strength –Minimum Individual) |
- |
150 |
|
- |
| Cl-9.6(Tensile Strength-Across the grain) |
- |
150 |
|
- |
| Cl-9.7(Glue Adhesion in Mycological test - Glue Shear Strength –Minimum Individual) |
- |
150 |
|
- |
| Cl-9.7(Glue Adhesion in Mycological test - Glue Shear Strength -Average) |
- |
150 |
|
- |
| Cl-9.8, Table-2(Static Bending Strength - Modulus of Rupture - Along the Face Grain - Average) |
- |
150 |
|
- |
| Cl-9.8, Table-2(Static Bending Strength - Modulus of Rupture - Along the Face Grain - Minimum Individual) |
- |
150 |
|
- |
| Cl-9.8, Table-2(Static Bending Strength - Modulus of Rupture - Across the Face Grain - Minimum Individual) |
- |
150 |
|
- |
| Cl-9.8, Table-2(Static Bending Strength - Modulus of Rupture - Across the Face Grain - Average) |
- |
150 |
|
- |
| Cl-11.1(Marking) |
- |
0 |
|
- |
| Cl-11.3(Marking) |
- |
0 |
|
- |
| Cl-9.11(Formaldehyde Content Test) |
- |
500 |
|
- |
| Cl-9.10(Retention of Preservative) |
- |
500 |
|
- |
| Cl-5.3(Treatment) |
- |
0 |
|
- |
| Cl-4.1(Timber) |
- |
0 |
|
- |
| Cl-4.2(Adhesive) |
- |
0 |
|
- |
| Cl-5.1(Veneers) |
- |
0 |
|
- |
| Cl-5.2.1(Glueing) |
- |
0 |
|
- |
| Cl -5.2.2(Thickness of Veneers) |
- |
0 |
|
- |
| Cl - 5.2.3.1(Joint in Veneers) |
- |
0 |
|
- |
| Cl - 5.2.3.2(Edge joints) |
- |
0 |
|
- |
| Cl - 5.2.3.3(End joints) |
- |
0 |
|
- |
| Cl - 5.2.3.4(Scarf joints) |
- |
0 |
|
- |
| Cl - 5.2.4(Grain Direction) |
- |
0 |
|
- |
| Cl-5.4(Moisture Content) |
- |
0 |
|
- |
| Cl-6.1(Dimensions (length)) |
- |
200 |
|
- |
| Cl-6.2(Thickness) |
- |
150 |
|
- |
| Cl-6.3(Squareness) |
- |
100 |
|
- |
| Cl-7.1, 7.2, 7.3, 7.4, 7.5 & 7.6(Workmanship and finish) |
- |
100 |
|
- |
| Cl-9.3(Moisture Content) |
- |
0 |
|
- |
| Cl-9.4.2(Glue Adhesion in Dry State- Adhesion of Plies) |
- |
200 |
|
- |
| Cl-9.4.1(Glue Adhesion in Dry State- Glue Shear Strength -Average) |
- |
200 |
|
- |
| Cl-9.5.1.1(Glue Adhesion in Water Resistance - Glue Shear Strength -Average) |
- |
200 |
|
- |
| Cl-9.5.1.2(Water Resistance Test-Adhesion of plies) |
- |
200 |
|
- |
| Cl-9.5.2(Water Resistance Test) |
- |
200 |
|
- |
| Cl-9.6(Tensile Strength-Along the grain) |
- |
200 |
|
- |
| Cl-9.7(Mycological Test -Adhesion) |
- |
200 |
|
- |
| Cl-9.8, Table-2(Static Bending Strength - Modulus of Elasticity - Along the Face Grain - Average) |
- |
200 |
|
- |
| Cl-9.8, Table-2(Static Bending Strength - Modulus of Elasticity - Along the Face Grain - Minimum Individual) |
- |
200 |
|
- |
| Cl-9.9, Table-3 (i) a((Modulus of Elasticity: Across the Face Grain: Average) Wet Bending) |
- |
200 |
|
- |
| Cl-9.9, Table-3 (i) b((Modulus of Elasticity: Across the Face Grain: Minimum Individual) Wet Bending) |
- |
200 |
|
- |
| Cl-9.4.2(Adhesion of Plies) |
- |
200 |
|
- |
| 5.1.1(Defects in veneers) |
- |
0 |
|
- |
| Cl-9.8, Table-2(Static Bending Strength - Modulus of Elasticity - Across the Face Grain - Average) |
- |
200 |
|
- |
| Cl-9.8, Table-2(Static Bending Strength - Modulus of Elasticity - Across the Face Grain - Minimum Individual) |
- |
200 |
|
- |
| Cl-9.9, Table-3 (ii) a((Modulus of Rupture: Across the Face Grain: Average) Wet Bending) |
- |
200 |
|
- |
| Cl-9.9, Table-3 (ii) b((Modulus of Rupture: Across the Face Grain: Minimum Individual) Wet Bending) |
- |
200 |
|
- |
| Cl-6.1(Dimensions (width)) |
- |
100 |
|
- |
| Cl-8.3(Edge Straightness) |
- |
100 |
|
- |
| Cl-9.4.1(Glue Adhesion in Dry State- Glue Shear Strength –Minimum Individual) |
- |
200 |
|
- |
| Cl-9.5.1.1(Glue Adhesion in Water Resistance - Glue Shear Strength –Minimum Individual) |
- |
200 |
|
- |
| Cl-9.6(Tensile Strength-Across the grain) |
- |
200 |
|
- |
| Cl-9.7(Glue Adhesion in Mycological test - Glue Shear Strength –Minimum Individual) |
- |
200 |
|
- |
| Cl-9.7(Glue Adhesion in Mycological test - Glue Shear Strength -Average) |
- |
200 |
|
- |
| Cl-9.8, Table-2(Static Bending Strength - Modulus of Rupture - Along the Face Grain - Average) |
- |
200 |
|
- |
| Cl-9.8, Table-2(Static Bending Strength - Modulus of Rupture - Along the Face Grain - Minimum Individual) |
- |
200 |
|
- |
| Cl-9.8, Table-2(Static Bending Strength - Modulus of Rupture - Across the Face Grain - Minimum Individual) |
- |
200 |
|
- |
| Cl-9.8, Table-2(Static Bending Strength - Modulus of Rupture - Across the Face Grain - Average) |
- |
200 |
|
- |
| Cl-11.1(Marking) |
- |
0 |
|
- |
| Cl-11.3(Marking) |
- |
0 |
|
- |
| Cl-9.11(Formaldehyde Content Test) |
- |
500 |
|
- |
| Cl-9.10(Retention of Preservative) |
- |
500 |
|
- |
| Cl-5.3(Treatment) |
- |
500 |
|
- |
|
26 Aug, 2027 |
- "1 Cl-9.12 (Steady-State Formaldehyde Emission Test) Steady-State Formaldehyde Emission Test Optional Test. |
| 1450 |
EKO PRO ENGINEERS PRIVATE LIMITED (32/41), GHAZIABAD
| 9179706
| IS 2494 : Part 1 (1994) |
V - Belts - Endless V - Belts for industrial purposes: Part 1 general purpose - Specification (Second Revision) |
ALL |
16500 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 11.0(Marking) |
- |
16500 |
|
- |
| 10.1(Elongation) |
- |
16500 |
|
- |
| 10.1(Tensile Strength) |
- |
16500 |
|
- |
| 8.0(Transmitting Capacities) |
- |
16500 |
|
- |
| 7.2.2(Matched Belts - Code) |
- |
16500 |
|
- |
| 7.2.1(Matched Belts - Difference) |
- |
16500 |
|
- |
| 7.1(Belt Pitch Length) |
- |
16500 |
|
- |
| 6.0(Designation) |
- |
16500 |
|
- |
| 5 Table 2B(Cross sectional dimension) |
- |
16500 |
|
- |
| 5 Table 2B(Cross sectional dimension) |
- |
16500 |
|
- |
| 5 Table 2A(Cross sectional dimension) |
- |
16500 |
|
- |
| 5 Table 2A(Cross sectional dimension) |
- |
16500 |
|
- |
| 5 Table 2A(Cross sectional dimension) |
- |
16500 |
|
- |
| 5 Table 2A(Cross sectional dimension) |
- |
16500 |
|
- |
| 5 Table 2A(Cross sectional dimension) |
- |
16500 |
|
- |
| 5 Table 2A(Cross sectional dimension) |
- |
16500 |
|
- |
| 5 Table 2A(Cross sectional dimension) |
- |
16500 |
|
- |
| 5 Table 2A(Cross sectional dimension) |
- |
16500 |
|
- |
| 5 Table 2A(Cross sectional dimension) |
- |
16500 |
|
- |
| 5 Table 1(Cross sectional dimension) |
- |
16500 |
|
- |
| 5 Table 1(Cross sectional dimension) |
- |
16500 |
|
- |
| 5 Table 1(Cross sectional dimension) |
- |
16500 |
|
- |
| 5 Table 1(Cross sectional dimension) |
- |
16500 |
|
- |
| 4.1(Material and Workmanship) |
- |
16500 |
|
- |
| 4.1(Material -Reinforcing polyester cord/fabric of the V-belts) |
- |
16500 |
|
- |
| 4.1(Material and Workmanship) |
- |
16500 |
|
- |
| 7.2(Test Matched Belts) |
- |
16500 |
|
- |
| 5 & 11(Test Belt ride position of top surface of belt with respect to top of pully groove.) |
- |
16500 |
|
- |
| Clause 5 Table 1(Nominal Pitch Width (Wp)) |
- |
16500 |
|
- |
| Clause 5 Table 1(Nominal Height (T)) |
- |
16500 |
|
- |
| Clause 5 Table 1(Nominal Included Angle (A)) |
- |
16500 |
|
- |
| Clause 5 Table 1(Nominal Pitch Width (W)) |
- |
16500 |
|
- |
| Cl-4.3(Presence of polychloroprene rubber on outside jacket of V-belt) |
- |
16500 |
|
- |
|
- |
- Included w.e.f-18.12.2025 |
| 1451 |
ACCURATE TEST SOLUTIONS LLP
| 8192806
| IS 17546 (2021) |
Chlorinated polyvinyl chloride CPVC fittings for potable hot and cold water distribution supplies Specification |
15 MM TO 150 MM |
100000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 3.1(Nominal Size(DN)) |
- |
500 |
|
- |
| 3.2(Nominal Outside Diameter) |
- |
500 |
|
- |
| 3.3(Mean Inside Diameter of Socket at Entry) |
- |
1000 |
|
- |
| 3.4(Mean Inside Diameter of Socket at Shoulder (Bottom)) |
- |
1000 |
|
- |
| 3.4(Mean Inside Diameter of Socket at Shoulder (Bottom)) |
- |
1000 |
|
- |
| 3.5(Out-of-Roundness (Ovality)) |
- |
1000 |
|
- |
| 3.6(Nominal Wall Thickness) |
- |
500 |
|
- |
| 3.7(Minimum Wall Thickness) |
- |
500 |
|
- |
| 3.8(Tolerance) |
- |
500 |
|
- |
| 3.9(Working Pressure) |
- |
500 |
|
- |
| 3.1(Standard Dimension Ratio) |
- |
500 |
|
- |
| 3.11(Type Tests) |
- |
70000 |
|
- |
| 3.11(Acceptance Tests) |
- |
40000 |
|
- |
| 6(Composition) |
- |
10000 |
|
- |
| 7(Dimensions of fitting) |
- |
2000 |
|
- |
| 8.2(Opacity) |
- |
2000 |
|
- |
| 8.1(Visual Appearance) |
- |
500 |
|
- |
| 8.3(Stress Relief Test) |
- |
2000 |
|
- |
| 8.4(Vicat softening Temperature) |
- |
2500 |
|
- |
| 8.5(Density) |
- |
2500 |
|
- |
| 8.6(Effect on water) |
- |
5000 |
|
- |
| 9(Mechanical Properties) |
- |
80000 |
|
- |
| 11(Marking) |
- |
500 |
|
- |
| Cl-6.2.2(Compound Chlorine Content) |
- |
3000 |
|
- |
| Cl-6.2.5(Verification of the Malfunction Temperature) |
- |
10000 |
|
- |
| Cl-9.1(Hydrostatic Characteristics) |
- |
20000 |
|
- |
| Cl-9.2(Thermal Stability by Hydrostatic Pressure Testing) |
- |
70000 |
|
- |
|
08 Dec, 2028 |
- Included w.e.f 30.01.2026 |
| 1452 |
Global Scientific Solution (P) Ltd.
| 8189526
| IS 302 : Part 2 : Sec 201 (2008) |
Safety of household and similar electrical appliances: Part 2 particular requirements: Sec 201 electric immersion water heaters (First Revision) |
portable electric immersion heaters for household and similar purpose, their rated voltage being not more than 250 V |
7500 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl.6 of IS 302-‐2-‐201:2008(Classification) |
- |
0 |
|
- |
| Cl.7 of IS 302-2-201:2008(Marking and Instruction ) |
- |
1000 |
|
- |
| Cl.7 of IS 302-2-201:2008(Marking and Instruction ) |
- |
1000 |
|
- |
| Cl.7 of IS 302-2-201:2008(Marking and Instruction ) |
- |
1000 |
|
- |
| Cl.7 of IS 302-2-201:2008(Marking and Instruction ) |
- |
1000 |
|
- |
| Cl.7 of IS 302-2-201:2008(Marking and Instruction ) |
- |
1000 |
|
- |
| Cl.7 of IS 302-2-201:2008(Marking and Instruction ) |
- |
1000 |
|
- |
| Cl.7 of IS 302-2-201:2008(Marking and Instruction ) |
- |
1000 |
|
- |
| Cl.7 of IS 302-2-201:2008(Marking and Instruction ) |
- |
1000 |
|
- |
| Cl.7 of IS 302-2-201:2008(Marking and Instruction ) |
- |
1000 |
|
- |
| Cl.7 of IS 302-2-201:2008(Marking and Instruction ) |
- |
1000 |
|
- |
| Cl.7 of IS 302-2-201:2008(Marking and Instruction ) |
- |
1000 |
|
- |
| Cl.7 of IS 302-2-201:2008(Marking and Instruction ) |
- |
1000 |
|
- |
| Cl.7 of IS 302-2-201:2008(Marking and Instruction ) |
- |
1000 |
|
- |
| Cl.7 of IS 302-2-201:2008(Marking and Instruction ) |
- |
1000 |
|
- |
| Cl.7 of IS 302-2-201:2008(Marking and Instruction ) |
- |
1000 |
|
- |
| Cl.7 of IS 302-2-201:2008(Marking and Instruction ) |
- |
1000 |
|
- |
| Cl.7 of IS 302-2-201:2008(Marking and Instruction ) |
- |
1000 |
|
- |
| Cl.7 of IS 302-2-201:2008(Marking and Instruction ) |
- |
1000 |
|
- |
| Cl.7 of IS 302-2-201:2008(Marking and Instruction ) |
- |
1000 |
|
- |
| Cl.7 of IS 302-2-201:2008(Marking and Instruction ) |
- |
1000 |
|
- |
| Cl.8 of IS 302‐2-201: 2008(Protection Against Access to Live Parts) |
- |
1000 |
|
- |
| Cl.10 of IS 302‐2‐201:2008(Power Input and Current ) |
- |
1000 |
|
- |
| Cl.11 of IS 302-2201: 2008(Heating) |
- |
1000 |
|
- |
| Cl.11 of IS 302-2201: 2008(Heating) |
- |
1000 |
|
- |
| Cl.11 of IS 302-2201: 2008(Heating) |
- |
1000 |
|
- |
| Cl.11 of IS 302-2201: 2008(Heating) |
- |
1000 |
|
- |
| Cl.11 of IS 302-2201: 2008(Heating) |
- |
1000 |
|
- |
| Cl.11 of IS 302-2201: 2008(Heating) |
- |
1000 |
|
- |
| Cl.11 of IS 302-2201: 2008(Heating) |
- |
1000 |
|
- |
| Cl.11 of IS 302-2201: 2008(Heating) |
- |
1000 |
|
- |
| Cl.11 of IS 302-2201: 2008(Heating) |
- |
1000 |
|
- |
| Cl.11 of IS 302-2201: 2008(Heating) |
- |
1000 |
|
- |
| Cl.13 of IS 302-2-201: 2008(Leakage Current & Electric Strength at Operating Temperature) |
- |
1000 |
|
- |
| Cl.14 of IS 302‐2-201:2008(Transient Over Voltages ) |
- |
1000 |
|
- |
| Cl.15 of IS 302-2-201:2008(Moisture Resistance ) |
- |
1000 |
|
- |
| Cl.15 of IS 302-2-201:2008(Moisture Resistance ) |
- |
1000 |
|
- |
| Cl.16 of IS 302-2-201:2008(Leakage Current & Electric Strength) |
- |
1000 |
|
- |
| Cl.16 of IS 302-2-201:2008(Leakage Current & Electric Strength) |
- |
1000 |
|
- |
| Cl.17 of IS 302‐2-201: 2008(Overload Protection of Transformers & Associated Circuits) |
- |
1000 |
|
- |
| Cl.19 of IS 302‐2-201: 2008(Abnormal Operation ) |
- |
1000 |
|
- |
| Cl.19 of IS 302‐2-201: 2008(Abnormal Operation ) |
- |
1000 |
|
- |
| Cl.19 of IS 302‐2-201: 2008(Abnormal Operation ) |
- |
1000 |
|
- |
| Cl.19 of IS 302‐2-201: 2008(Abnormal Operation ) |
- |
1000 |
|
- |
| Cl.20 of IS 302-2-201: 2008(Stability & Mechanical Hazards) |
- |
1000 |
|
- |
| Cl.21 of IS 302-2-201: 2008(Mechanical Strength ) |
- |
1000 |
|
- |
| Cl.21 of IS 302-2-201: 2008(Mechanical Strength ) |
- |
1000 |
|
- |
| Cl.21 of IS 302-2-201: 2008(Mechanical Strength ) |
- |
1000 |
|
- |
| Cl.22 of IS 302-2-201: 2008(Construction) |
- |
1000 |
|
- |
| Cl.23 of 302-2-201:2008(Internal Wiring ) |
- |
1000 |
|
- |
| Cl.23 of 302-2-201:2008(Internal Wiring ) |
- |
1000 |
|
- |
| Cl.23 of 302-2-201:2008(Internal Wiring ) |
- |
1000 |
|
- |
| Cl.23 of 302-2-201:2008(Internal Wiring ) |
- |
1000 |
|
- |
| Cl.23 of 302-2-201:2008(Internal Wiring ) |
- |
1000 |
|
- |
| Cl.23 of 302-2-201:2008(Internal Wiring ) |
- |
1000 |
|
- |
| Cl.23 of 302-2-201:2008(Internal Wiring ) |
- |
1000 |
|
- |
| Cl.23 of 302-2-201:2008(Internal Wiring ) |
- |
1000 |
|
- |
| Cl.23 of 302-2-201:2008(Internal Wiring ) |
- |
1000 |
|
- |
| Cl.24 of IS 302-2-201: 2008(Component) |
- |
1000 |
|
- |
| Cl.24 of IS 302-2-201: 2008(Component) |
- |
1000 |
|
- |
| Cl.24 of IS 302-2-201: 2008(Component) |
- |
1000 |
|
- |
| Cl.24 of IS 302-2-201: 2008(Component) |
- |
1000 |
|
- |
| Cl.24 of IS 302-2-201: 2008(Component) |
- |
1000 |
|
- |
| Cl.24 of IS 302-2-201: 2008(Component) |
- |
1000 |
|
- |
| Cl.24 of IS 302-2-201: 2008(Component) |
- |
1000 |
|
- |
| Cl.24 of IS 302-2-201: 2008(Component) |
- |
1000 |
|
- |
| Cl.24 of IS 302-2-201: 2008(Component) |
- |
1000 |
|
- |
| Cl.25 of IS 302-2-201: 2008(Supply Connection and External Flexible Cords) |
- |
1000 |
|
- |
| Cl.25 of IS 302-2-201: 2008(Supply Connection and External Flexible Cords) |
- |
1000 |
|
- |
| Cl.25 of IS 302-2-201: 2008(Supply Connection and External Flexible Cords) |
- |
1000 |
|
- |
| Cl.25 of IS 302-2-201: 2008(Supply Connection and External Flexible Cords) |
- |
1000 |
|
- |
| Cl.25 of IS 302-2-201: 2008(Supply Connection and External Flexible Cords) |
- |
1000 |
|
- |
| Cl.25 of IS 302-2-201: 2008(Supply Connection and External Flexible Cords) |
- |
1000 |
|
- |
| Cl.25 of IS 302-2-201: 2008(Supply Connection and External Flexible Cords) |
- |
1000 |
|
- |
| Cl.25 of IS 302-2-201: 2008(Supply Connection and External Flexible Cords) |
- |
1000 |
|
- |
| Cl.25 of IS 302-2-201: 2008(Supply Connection and External Flexible Cords) |
- |
1000 |
|
- |
| Cl.25 of IS 302-2-201: 2008(Supply Connection and External Flexible Cords) |
- |
1000 |
|
- |
| Cl.25 of IS 302-2-201: 2008(Supply Connection and External Flexible Cords) |
- |
1000 |
|
- |
| Cl.25 of IS 302-2-201: 2008(Supply Connection and External Flexible Cords) |
- |
1000 |
|
- |
| Cl.25 of IS 302-2-201: 2008(Supply Connection and External Flexible Cords) |
- |
1000 |
|
- |
| Cl.25 of IS 302-2-201: 2008(Supply Connection and External Flexible Cords) |
- |
1000 |
|
- |
| Cl.25 of IS 302-2-201: 2008(Supply Connection and External Flexible Cords) |
- |
1000 |
|
- |
| Cl.25 of IS 302-2-201: 2008(Supply Connection and External Flexible Cords) |
- |
1000 |
|
- |
| Cl.25 of IS 302-2-201: 2008(Supply Connection and External Flexible Cords) |
- |
1000 |
|
- |
| Cl.25 of IS 302-2-201: 2008(Supply Connection and External Flexible Cords) |
- |
1000 |
|
- |
| Cl.25 of IS 302-2-201: 2008(Supply Connection and External Flexible Cords) |
- |
1000 |
|
- |
| Cl.25 of IS 302-2-201: 2008(Supply Connection and External Flexible Cords) |
- |
1000 |
|
- |
| Cl.26 of IS 302-2-201: 2008(Terminals for External Conductors) |
- |
1000 |
|
- |
| Cl.27 of IS 302-2-201: 2008(Provision for Earthing ) |
- |
1000 |
|
- |
| Cl.27 of IS 302-2-201: 2008(Provision for Earthing ) |
- |
1000 |
|
- |
| Cl.27 of IS 302-2-201: 2008(Provision for Earthing ) |
- |
1000 |
|
- |
| Cl.27 of IS 302-2-201: 2008(Provision for Earthing ) |
- |
1000 |
|
- |
| Cl.27 of IS 302-2-201: 2008(Provision for Earthing ) |
- |
1000 |
|
- |
| Cl.27 of IS 302-2-201: 2008(Provision for Earthing ) |
- |
1000 |
|
- |
| Cl.28 of IS 302-2-201: 2008(Screws & Connections ) |
- |
1000 |
|
- |
| Cl.29 of IS 302-2‐201:2008(Clearances, Creepage Distances and Solid Insulation ) |
- |
1000 |
|
- |
| Cl.30 of IS 302-2‐201:2008(Resistance to Heat and Fire ) |
- |
1000 |
|
- |
| Cl.31 of IS 302-2-201:2008(Resistance of Rusting ) |
- |
1000 |
|
- |
| Cl.32 of IS 302-2-201:2008(Radiation, Toxicity and Similar Hazards) |
- |
1000 |
|
- |
| 4(GENERAL REQUIREMENTS) |
- |
0 |
|
- |
| 5(GENERAL CONDITIONS FOR THE TESTS) |
- |
0 |
|
- |
| Cl.11 of IS 302-2201: 2008(Heating) |
- |
1000 |
|
- |
|
31 Oct, 2028 |
- Included w.e.f. 01.04.2026
Exclusion: "19.11.4.7 (Harmonics)
19.11.4.6 (Class 3 Voltage dips and interruptions)
19.11.4.5 (Immunity to conducted discharges)
19.11.4.4 (Surge immunity test)
19.11.4.3 (Fast transient bursts)
19.11.4.2 (Radiated fields)
19.11.4.1 (Electrostatic discharges)
" |
| 1453 |
MIGHTY TESTING PRIVATE LIMITED, GHAZIABAD
| 8185126
| IS 10322 : Part 5 : Sec 7 (2017) |
Luminaires: Part 5 particular requirements: Sec 7 lighting chains (First Revision) |
- |
25000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 20.4(General Test Requireements) |
- |
0 |
|
- |
| 20.5(Classification of Luminaires') |
- |
1000 |
|
- |
| 20.6(Marking) |
- |
2000 |
|
- |
| 20.7(Construction) |
- |
2000 |
|
- |
| 20.8(Creepage Distance and Clearances) |
- |
2000 |
|
- |
| 20.9(Provision for earthing) |
- |
0 |
|
- |
| 20.10(Terminals) |
- |
2000 |
|
- |
| 20.11(External & Internal Wiring) |
- |
2000 |
|
- |
| 20.12(Protection against electric shock) |
- |
2000 |
|
- |
| 20.13(Endurance Tests and Thermal Tests) |
- |
4000 |
|
- |
| 20.14(Resistance to Dust & Moisture) |
- |
4000 |
|
- |
| 20.15(Insulation Resistance and Electric Strength) |
- |
2000 |
|
- |
| 20.16(Resistance to Heat , fire and tracking) |
- |
2000 |
|
- |
| 20.4(General Test Requireements) |
- |
0 |
|
- |
| 20.5(Classification of Luminaires') |
- |
0 |
|
- |
| 20.6(Marking) |
- |
0 |
|
- |
| 20.7(Construction) |
- |
0 |
|
- |
| 20.8(Creepage Distance and Clearances) |
- |
0 |
|
- |
| 20.9(Provision for earthing) |
- |
0 |
|
- |
| 20.10(Terminals) |
- |
0 |
|
- |
| 20.11(External & Internal Wiring) |
- |
0 |
|
- |
| 20.12(Protection against electric shock) |
- |
0 |
|
- |
| 20.13(Endurance Tests and Thermal Tests) |
- |
0 |
|
- |
| 20.14(Resistance to Dust & Moisture) |
- |
0 |
|
- |
| 20.15(Insulation Resistance and Electric Strength) |
- |
0 |
|
- |
| 20.16(Resistance to Heat , fire and tracking) |
- |
0 |
|
- |
|
05 May, 2028 |
- "Sl. No. Clause No. Name of Test Technical justification for seeking exclusion
1. 20.7 (Construction) Cl.4.24 (Photobiological hazards), Cl.4.26(Short-Circuit protection) Costly Test facility. |
| 1454 |
MIGHTY TESTING PRIVATE LIMITED, GHAZIABAD
| 8185126
| IS 16103 : Part 1 (2025) |
LED Modules for General Lighting Part 1 Safety Specifications (First Revision) |
- |
26000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl-6(Marking) |
- |
2000 |
|
- |
| Cl-7.1(Integral terminals) |
- |
2000 |
|
- |
| Cl-7.2(Terminals other than integral terminals) |
- |
2000 |
|
- |
| Cl-8(Earthing) |
- |
2000 |
|
- |
| Cl-9(Protection against accidental contact with live parts) |
- |
2000 |
|
- |
| Cl-10(Moisture resistance and insulation) |
- |
2000 |
|
- |
| Cl-11(Electric strength) |
- |
2000 |
|
- |
| Cl-12.1(Fault conditions- General) |
- |
1000 |
|
- |
| Cl-12.2(Overpower condition) |
- |
1000 |
|
- |
| Cl-13(Conformity testing during manufacture) |
- |
0 |
|
- |
| Cl-15(Creepage distances and clearances) |
- |
2000 |
|
- |
| Cl-16(Screws, current-carrying parts and connections) |
- |
2000 |
|
- |
| Cl-17(Resistance to heat, fire and tracking) |
- |
2000 |
|
- |
| Cl-18(Resistance to corrosion) |
- |
2000 |
|
- |
| Cl-19(Information for luminaire design) |
- |
0 |
|
- |
| Cl-20.1(Heat management- General) |
- |
500 |
|
- |
| Cl-20.2(Thermal interface material) |
- |
500 |
|
- |
| Cl-20.3(Heat protection) |
- |
1000 |
|
- |
|
05 May, 2028 |
- Included w.e.f 30.01.2026
Exclusion: Cl-21.1 (UV radiation), Cl-21.2 (Blue light hazard) |
| 1455 |
MIGHTY TESTING PRIVATE LIMITED, GHAZIABAD
| 8185126
| IS 302 : Part 2 : Sec 6 (2009) |
Safety of household and similar electrical appliances: Part 2 particular requirements: Sec 6 cooking ranges, hobs, ovens and similar appliances (First Revision) |
Excluding Pyrolytics self-cleaning ovens |
14000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 6.0(Classification) |
- |
0 |
|
- |
| 7.0(Marking and instructions) |
- |
500 |
|
- |
| 8.0(Protection against access to live part test) |
- |
500 |
|
- |
| 9.0(Starting of motor-operated appliances test) |
- |
0 |
|
- |
| 10.0(Power Input and current test) |
- |
1000 |
|
- |
| 11.0(Heating test) |
- |
1000 |
|
- |
| 13.0(Leakage current and electric strength test) |
- |
500 |
|
- |
| 14.0(Transient voltages) |
- |
500 |
|
- |
| 15.0(Moisture Resistance) |
- |
1000 |
|
- |
| 16.0(Leakage current and electric strength test) |
- |
500 |
|
- |
| 17.0(Overload protection of transformers test) |
- |
500 |
|
- |
| 18.0(Endurance test) |
- |
0 |
|
- |
| 19.0(Abnormal Operations) |
- |
1000 |
|
- |
| 20.0(Stability and Mechanical Hazards) |
- |
500 |
|
- |
| 21.0(Mechanical Strength) |
- |
500 |
|
- |
| 22.0(Construction verification related tests) |
- |
500 |
|
- |
| 23.0(Internal wiring) |
- |
500 |
|
- |
| 24.0(Components) |
- |
500 |
|
- |
| 25.0(Supply connections and External Flexible Cords) |
- |
500 |
|
- |
| 26.0(Terminal for External Conductors) |
- |
500 |
|
- |
| 27.0(Provision for Earthing) |
- |
500 |
|
- |
| 28.0(Screws and connections) |
- |
500 |
|
- |
| 29.0(Clearances and Creepage distances and solid insulation) |
- |
1000 |
|
- |
| 30.0(Resistance to heat and fire) |
- |
1000 |
|
- |
| 31.0(Resistance to rusting) |
- |
500 |
|
- |
| 4(General Requirements) |
- |
0 |
|
- |
| 5(General condition for the tests) |
- |
0 |
|
- |
|
05 May, 2028 |
- Included w.e.f 15.01.2026
Exclusion: Cl 19.11.4.1 -19.11.4.7(EMI/EMC), 32.0 (Radiation, Toxicity and Similar hazards) |
| 1456 |
DYNAMIC TEST LABORATORIES LLP
| 9197626
| IS 4246 (2025) |
DOMESTIC GAS STOVE AND BUILT IN HOB FOR USE WITH LPG SPECIFICATION (Sixth Revision ) |
Mechanical |
13000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4.1(General - IS 4246 : 2025) |
- |
500 |
|
- |
| 4.1(General - IS 4246 : 2025) |
- |
500 |
|
- |
| 4.1.1(General - IS 4246 : 2025) |
- |
500 |
|
- |
| 5(Materials - Cl. 5 of IS 5116) |
- |
500 |
|
- |
| 5.1.1(Materials - Toughened glass, if provided,) |
- |
500 |
|
- |
| 5.1.1(Materials - Toughened glass, if provided,) |
- |
500 |
|
- |
| 5.1.1(Materials - Toughened glass, if provided,) |
- |
500 |
|
- |
| 5.1.1(Materials - Toughened glass, if provided,) |
- |
500 |
|
- |
| 5.1.1(Materials - Toughened glass, if provided,) |
- |
500 |
|
- |
| 5.1.1(Materials - Toughened glass, if provided,) |
- |
500 |
|
- |
| 5.1.1(Materials - Toughened glass, if provided,) |
- |
500 |
|
- |
| 5.1.1(Materials - Toughened glass, if provided,) |
- |
500 |
|
- |
| 5.1.1(Materials - Toughened glass, if provided,) |
- |
500 |
|
- |
| 5.1(Materials - IS 5116) |
- |
500 |
|
- |
| 5.1(Materials - IS 5116) |
- |
500 |
|
- |
| 5.1.1(Materials - IS 5116) |
- |
500 |
|
- |
| 5.1.1(Materials - IS 5116) |
- |
500 |
|
- |
| 5.2(Materials - IS 5116) |
- |
500 |
|
- |
| 5.2(Materials - IS 5116) |
- |
500 |
|
- |
| 5.3(Materials - IS 5116) |
- |
500 |
|
- |
| 5.5(Materials - IS 5116) |
- |
500 |
|
- |
| 5.5(Materials - IS 5116) |
- |
500 |
|
- |
| 5.5(Materials - IS 5116) |
- |
500 |
|
- |
| 5.7(Materials - IS 5116) |
- |
500 |
|
- |
| 6.1(Design for Maintainance) |
- |
500 |
|
- |
| 6.1(Design for Maintainance) |
- |
500 |
|
- |
| 6.2(Design for Maintainance) |
- |
500 |
|
- |
| 6.2(Design for Maintainance) |
- |
500 |
|
- |
| 6.3(Design for Maintainance) |
- |
500 |
|
- |
| 6.4(Design for Maintainance) |
- |
500 |
|
- |
| 6.5(Design for Maintainance) |
- |
500 |
|
- |
| 6.6(Design for Maintainance) |
- |
500 |
|
- |
| 7.0(Rigidity and Stability) |
- |
500 |
|
- |
| 7.1(Rigidity and Stability) |
- |
500 |
|
- |
| 7.2(Rigidity and Stability) |
- |
500 |
|
- |
| 7.3(Rigidity and Stability) |
- |
500 |
|
- |
| 8.1(Workmanship and Finish - Cl. 7 of IS 5116) |
- |
500 |
|
- |
| 8.1(Workmanship and Finish - Cl. 7 of IS 5116) |
- |
500 |
|
- |
| 8.1(Workmanship and Finish - Cl. 7 of IS 5116) |
- |
500 |
|
- |
| 8.1(Workmanship and Finish - Cl. 7 of IS 5116) |
- |
500 |
|
- |
| 8.1(Workmanship and Finish - Cl. 7 of IS 5116) |
- |
500 |
|
- |
| 8.1(Workmanship and Finish - Cl. 7 of IS 5116) |
- |
500 |
|
- |
| 8.1(Workmanship and Finish - Cl. 7 of IS 5116) |
- |
500 |
|
- |
| 8.1(Workmanship and Finish - Cl. 7 of IS 5116) |
- |
500 |
|
- |
| 8.1(Workmanship and Finish - Cl. 7 of IS 5116) |
- |
500 |
|
- |
| 8.1(Workmanship and Finish - Cl. 7 of IS 5116) |
- |
500 |
|
- |
| 8.1(Workmanship and Finish - Cl. 7 of IS 5116) |
- |
500 |
|
- |
| 8.1(Workmanship and Finish - Cl. 7 of IS 5116) |
- |
500 |
|
- |
| 8.2(Workmanship and Finish -) |
- |
500 |
|
- |
| 8.3(Workmanship and Finish -) |
- |
500 |
|
- |
| 9(Gas Taps- Cl. 8 of IS 5116 (Except 8.7 and 8.11.1)) |
- |
500 |
|
- |
| 9(Gas Taps- Cl. 8 of IS 5116 (Except 8.7 and 8.11.1)) |
- |
500 |
|
- |
| 9(Gas Taps- Cl. 8 of IS 5116 (Except 8.7 and 8.11.1)) |
- |
500 |
|
- |
| 9(Gas Taps- Cl. 8 of IS 5116 (Except 8.7 and 8.11.1)) |
- |
500 |
|
- |
| 9(Gas Taps- Cl. 8 of IS 5116 (Except 8.7 and 8.11.1)) |
- |
500 |
|
- |
| 9(Gas Taps- Cl. 8 of IS 5116 (Except 8.7 and 8.11.1)) |
- |
500 |
|
- |
| 9(Gas Taps- Cl. 8 of IS 5116 (Except 8.7 and 8.11.1)) |
- |
500 |
|
- |
| 9(Gas Taps- Cl. 8 of IS 5116 (Except 8.7 and 8.11.1)) |
- |
500 |
|
- |
| 9(Gas Taps- Cl. 8 of IS 5116 (Except 8.7 and 8.11.1)) |
- |
500 |
|
- |
| 9(Gas Taps- Cl. 8 of IS 5116 (Except 8.7 and 8.11.1)) |
- |
500 |
|
- |
| 9(Gas Taps- Cl. 8 of IS 5116 (Except 8.7 and 8.11.1)) |
- |
500 |
|
- |
| 9(Gas Taps- Cl. 8 of IS 5116 (Except 8.7 and 8.11.1)) |
- |
500 |
|
- |
| 9(Gas Taps- Cl. 8 of IS 5116 (Except 8.7 and 8.11.1)) |
- |
500 |
|
- |
| 9(Gas Taps- Cl. 8 of IS 5116 (Except 8.7 and 8.11.1)) |
- |
500 |
|
- |
| 9(Gas Taps- Cl. 8 of IS 5116 (Except 8.7 and 8.11.1)) |
- |
500 |
|
- |
| 9(Gas Taps- Cl. 8 of IS 5116 (Except 8.7 and 8.11.1)) |
- |
500 |
|
- |
| 9(Gas Taps- Cl. 8 of IS 5116 (Except 8.7 and 8.11.1)) |
- |
500 |
|
- |
| 9(Gas Taps- Cl. 8 of IS 5116 (Except 8.7 and 8.11.1)) |
- |
500 |
|
- |
| 9(Gas Taps- Cl. 8 of IS 5116 (Except 8.7 and 8.11.1)) |
- |
500 |
|
- |
| 9(Gas Taps- Cl. 8 of IS 5116 (Except 8.7 and 8.11.1)) |
- |
500 |
|
- |
| 9(Gas Taps- Cl. 8 of IS 5116 (Except 8.7 and 8.11.1)) |
- |
500 |
|
- |
| 9(Gas Taps- Cl. 8 of IS 5116 (Except 8.7 and 8.11.1)) |
- |
500 |
|
- |
| 9(Gas Taps- Cl. 8 of IS 5116 (Except 8.7 and 8.11.1)) |
- |
500 |
|
- |
| 10(Injector Jets) |
- |
500 |
|
- |
| 10(Injector Jets) |
- |
500 |
|
- |
| 10(Injector Jets) |
- |
500 |
|
- |
| 10(Injector Jets) |
- |
500 |
|
- |
| 10(Injector Jets) |
- |
500 |
|
- |
| 10(Injector Jets) |
- |
500 |
|
- |
| 11.1(Burners- Cl. 10 of IS 5116) |
- |
500 |
|
- |
| 11.1(Burners- Cl. 10 of IS 5116) |
- |
500 |
|
- |
| 11.1(Burners- Cl. 10 of IS 5116) |
- |
500 |
|
- |
| 11.1(Burners- Cl. 10 of IS 5116) |
- |
500 |
|
- |
| 11.1(Burners- Cl. 10 of IS 5116) |
- |
500 |
|
- |
| 11.2(Burners) |
- |
500 |
|
- |
| 11.3(Burners) |
- |
500 |
|
- |
| 11.4(Burners) |
- |
500 |
|
- |
| 12.1(Burner Pan Support) |
- |
500 |
|
- |
| 12.2(Burner Pan Support) |
- |
500 |
|
- |
| 12.3(Burner Pan Support) |
- |
500 |
|
- |
| 13.1(Gas Soundness Test - Cl. 16 of IS 5116) |
- |
1000 |
|
- |
| 13,2(Gas Soundness Test) |
- |
1000 |
|
- |
| 13.2(Gas Leak Detector) |
- |
1000 |
|
- |
| 14.1(Gas Inlet Connection - Cl. 18 of IS 5116) |
- |
1000 |
|
- |
| 14.1(Gas Inlet Connection - Cl. 18 of IS 5116) |
- |
1000 |
|
- |
| 14.1(Gas Inlet Connection - Cl. 18 of IS 5116) |
- |
1000 |
|
- |
| 14.1(Gas Inlet Connection - Cl. 18 of IS 5116) |
- |
1000 |
|
- |
| 14.1(Gas Inlet Connection - Cl. 18 of IS 5116) |
- |
1000 |
|
- |
| 14.1(Gas Inlet Connection - Cl. 18 of IS 5116) |
- |
1000 |
|
- |
| 14.1(Gas Inlet Connection - Cl. 18 of IS 5116) |
- |
1000 |
|
- |
| 14.1(Gas Inlet Connection - Cl. 18 of IS 5116) |
- |
1000 |
|
- |
| 14.1(Gas Inlet Connection - Cl. 18 of IS 5116) |
- |
1000 |
|
- |
| 14.1(Gas Inlet Connection - Cl. 18 of IS 5116) |
- |
1000 |
|
- |
| 14.1(Gas Inlet Connection - Cl. 18 of IS 5116) |
- |
1000 |
|
- |
| 14.1(Gas Inlet Connection - Cl. 18 of IS 5116) |
- |
1000 |
|
- |
| 14.1(Gas Inlet Connection - Cl. 18 of IS 5116) |
- |
1000 |
|
- |
| 14.2(Gas Inlet Connection) |
- |
1000 |
|
- |
| 14.2(Gas Inlet Connection) |
- |
1000 |
|
- |
| 14.2(Gas Inlet Connection) |
- |
1000 |
|
- |
| 14.2(Gas Inlet Connection) |
- |
1000 |
|
- |
| 14.3(Gas Inlet Connection) |
- |
1000 |
|
- |
| 14.4(Gas Inlet Connection) |
- |
1000 |
|
- |
| 14.5(Gas Inlet Connection - Cl. 17.3 of IS 5116) |
- |
1000 |
|
- |
| 14.6(Gas Inlet Connection) |
- |
1000 |
|
- |
| 15.0(Strength and Rigidity) |
- |
1000 |
|
- |
| 15.0(Strength and Rigidity) |
- |
1000 |
|
- |
| 15.0(Strength and Rigidity) |
- |
1000 |
|
- |
| 15.0(Strength and Rigidity) |
- |
1000 |
|
- |
| 17.0(Gas Consumption Test) |
- |
1000 |
|
- |
| 17.0(Gas Consumption Test) |
- |
1000 |
|
- |
| 17.0(Gas Consumption Test) |
- |
1000 |
|
- |
| 17.0(Gas Consumption Test) |
- |
1000 |
|
- |
| 17.0(Gas Consumption Test) |
- |
1000 |
|
- |
| 17.0(Gas Consumption Test) |
- |
1000 |
|
- |
| 17.2(Gas Consumption Test - For Gas Stoves) |
- |
1000 |
|
- |
| 17.2 (a)(Gas Consumption Test - For Gas Stoves) |
- |
1000 |
|
- |
| 17.2 (b)(Gas Consumption Test - For Gas Stoves) |
- |
1000 |
|
- |
| 17.2 (c)(Gas Consumption Test - For Gas Stoves) |
- |
1000 |
|
- |
| 17.3(Gas Consumption Test - For Built in Hobs) |
- |
1000 |
|
- |
| 17.3.1(Gas Consumption Test - For Built in Hobs) |
- |
1000 |
|
- |
| 17.3.2(Gas Consumption Test - For Built in Hobs) |
- |
1000 |
|
- |
| 18.1(Ignition and Flame Travel) |
- |
1000 |
|
- |
| 18.1(Ignition and Flame Travel) |
- |
1000 |
|
- |
| 18.2(Ignition and Flame Travel) |
- |
1000 |
|
- |
| 18.3(Ignition and Flame Travel) |
- |
1000 |
|
- |
| 18.4(Ignition and Flame Travel - Cl. 14 of IS 5116) |
- |
1000 |
|
- |
| 18.4(Ignition and Flame Travel - Cl. 14 of IS 5116) |
- |
1000 |
|
- |
| 18.4(Ignition and Flame Travel - Cl. 14 of IS 5116) |
- |
1000 |
|
- |
| 18.4(Ignition and Flame Travel - Cl. 14 of IS 5116) |
- |
1000 |
|
- |
| 18.4(Ignition and Flame Travel - Cl. 14 of IS 5116) |
- |
1000 |
|
- |
| 18.4(Ignition and Flame Travel - Cl. 14 of IS 5116) |
- |
1000 |
|
- |
| 19.1(Flame Stability) |
- |
1000 |
|
- |
| 19.1.1(Flame Stability) |
- |
1000 |
|
- |
| 19.2(Flame Stability) |
- |
1000 |
|
- |
| 19.3(Flame Stability) |
- |
1000 |
|
- |
| 20(Noise Control) |
- |
1000 |
|
- |
| 21(Flash Back) |
- |
1000 |
|
- |
| 22(Formation of Soot) |
- |
1000 |
|
- |
| 23(Resistance to Draught) |
- |
1000 |
|
- |
| 24.1(Combustion) |
- |
1000 |
|
- |
| 24.1(Combustion) |
- |
1000 |
|
- |
| 24.2(Combustion) |
- |
1000 |
|
- |
| 25.1(Fire Hazard and Limiting Temperatures) |
- |
1000 |
|
- |
| 25.1(Fire Hazard and Limiting Temperatures) |
- |
1000 |
|
- |
| 25.1(Fire Hazard and Limiting Temperatures) |
- |
1000 |
|
- |
| 25.1(Fire Hazard and Limiting Temperatures) |
- |
1000 |
|
- |
| 25.2(Fire Hazard and Limiting Temperatures) |
- |
1000 |
|
- |
| 26.1(Thermal Efficiency- Gas Stoves) |
- |
1000 |
|
- |
| 26.1(Thermal Efficiency- Gas Stoves) |
- |
1000 |
|
- |
| 26.1(Thermal Efficiency- Gas Stoves) |
- |
1000 |
|
- |
| 26.1(Thermal Efficiency- Gas Stoves) |
- |
1000 |
|
- |
| 26.1(Thermal Efficiency- Gas Stoves) |
- |
1000 |
|
- |
| 26.2(Thermal Efficiency- For Built in Hobs) |
- |
1000 |
|
- |
| 26.2(Thermal Efficiency- For Built in Hobs) |
- |
1000 |
|
- |
| 26.2(Thermal Efficiency- For Built in Hobs) |
- |
1000 |
|
- |
| 26.2(Thermal Efficiency- For Built in Hobs) |
- |
1000 |
|
- |
| 26.2(Thermal Efficiency- For Built in Hobs) |
- |
1000 |
|
- |
|
- |
- - |
| 1457 |
VERTEX TESTING LABORATORY PRIVATE LIMITED, GHAZIABAD
| 8185906
| IS 12823 (2025) |
Prelaminated Medium Density Particle Boards from Wood and other Lignocellulosic Material Specification (Second Revision) |
REG,MR,HMR/Type-1,2,3&4/Class-E1,E2/All Size |
15500 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| As per Clause 5(Material - IS 3087) |
- |
600 |
|
- |
| As per Clause 8 Table 2(Length -IS 2380 (Part 2)) |
- |
600 |
|
- |
| As per Clause 8 Table 2(Width - IS 2380 (Part 2)) |
- |
600 |
|
- |
| As per Clause 8 Table 2(Thickness - IS 2380 (Part 2)) |
- |
600 |
|
- |
| As per Clause 8 Table 2(Squareness, Max -IS 2380 (Part 2)) |
- |
600 |
|
- |
| As per Clause 8 Table 2(Edge Straighness, Max - IS 2380 (Part 2)) |
- |
600 |
|
- |
| As per Clause 9.1 Table 3(Density -IS 2380 (Part 3)) |
- |
600 |
|
- |
| As per Clause 9.1 Table 3(Variation from mean density, --IS 2380 (Part 3)) |
- |
600 |
|
- |
| As per Clause 9.1 Table 3(Moisture Content -IS 2380 (Part 3)) |
- |
600 |
|
- |
| As per Clause 9.1 Table 4, Table 5, Table 6, Table 7(Modulus of rupture (MoR), Min.-IS 2380 (Part 4)) |
- |
600 |
|
- |
| As per Clause 9.1 Table 4, Table 6, Table 7(Modulus of elasticity (MoE), Min. -(IS 2380 (Part 4)) |
- |
600 |
|
- |
| As per Clause 9.1 Table 4, Table 5, Table 6, Table7(Internal bond strength, Min. - IS 2380 (Part 5)) |
- |
600 |
|
- |
| As per Clause 9.1 Table 6, Table 7(24 h thickness swelling (due to general absorption) Max. - IS 2380 (Part 17)) |
- |
600 |
|
- |
| As per Clause 9.1 Table 4, Table 5, Table 6, Table 7(Screw withdrawal strength (face) , Min. -IS 2380 (Part 4)) |
- |
600 |
|
- |
| As per Clause 9.1 Table 4, Table 5, table 6, Table 7(Screw withdrawal strength (edge) , Min. -IS 2380 (Part 4)) |
- |
600 |
|
- |
| As per Clause 9.1 , Table 6, Table 7(Moisture Resistance : Option 1 : Cyclic test (1. )Internal bond strength Min. -IS 2380 (Part 5) see note 1) |
- |
600 |
|
- |
| As per Clause 9.1 , Table 6, Table 7(Moisture Resistance : Option 2 : Boil test (1.) Internal bond strength , Min.- IS 2380 (Part 5) see note 2) |
- |
600 |
|
- |
| As per Clause 9.1 , Table 8(Abrasion resistance in number of revolutions Min. --Annex. B) |
- |
900 |
|
- |
| As per Clause 9.1 , Table 8(Resiatnce to stream/water vapour - Annex. C) |
- |
600 |
|
- |
| As per Clause 9.1 , Table 8(Resitance to crack -Annex. D) |
- |
600 |
|
- |
| As per Clause 9.1 , Table 8(Resistance to cigarette burn -Annex. E) |
- |
600 |
|
- |
| As per Clause 9.1 , Table 8(Resiatnce to stain - Annex. F) |
- |
600 |
|
- |
| As per Clause 9.1 , Table 9(Formaldehyde content Fc, mg/100 g for oven dry board -IS 13745) |
- |
1000 |
|
- |
| As per Clause 9.1 , Table 9(Steady-state formaldehyde emission, Fc, mg/m3 (optional test)) |
- |
1000 |
|
- |
|
23 May, 2028 |
- Included w.e.f 18.12.2025 |
| 1458 |
Samridhi Test House Pvt. Ltd.
| 8184706
| IS 302 : Part 2 : Sec 15 (2009) |
Safety of household and similar electrical appliances: Part 2 particular requirements: Sec 15 appliances for heating liquids (First Revision) |
All Grade / Type / Size / Designation |
9900 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 6.0(Classification) |
- |
300 |
|
- |
| 7(Marking and instructions) |
- |
300 |
|
- |
| 8(Protection against live parts) |
- |
250 |
|
- |
| 9(STARTING OF MOTOR-OPERATED APPLIANCES) |
- |
0 |
|
- |
| 10(POWER INPUT AND CURRENT) |
- |
400 |
|
- |
| 11(HEATING) |
- |
500 |
|
- |
| 13(LEAKAGE CURRENT AND ELECTRIC STRENGTH AT OPERATING TEMPERATURE) |
- |
500 |
|
- |
| 14(TRANSIENT OVERVOLTAGES) |
- |
400 |
|
- |
| 15(MOISTURE RESISTANCE) |
- |
500 |
|
- |
| 16(LEAKAGE CURRENT AND ELECTRIC STRENGTH) |
- |
200 |
|
- |
| 17(OVERLOAD PROTECTION OF TRANSFORMERS AND ASSOCIATED CIRCUITS) |
- |
300 |
|
- |
| 18(ENDURANCE) |
- |
0 |
|
- |
| 19(ABNORMAL OPERATION) |
- |
300 |
|
- |
| 20(STABILITY AND MECHANICAL HAZARDS) |
- |
300 |
|
- |
| 21(MECHANICAL STRENGTH) |
- |
500 |
|
- |
| 22(CONSTRUCTION) |
- |
300 |
|
- |
| 23(INTERNAL WIRING) |
- |
300 |
|
- |
| 24(COMPONENTS) |
- |
300 |
|
- |
| 25(SUPPLY CONNECTION AND EXTERNAL FLEXIBLE CORDS) |
- |
400 |
|
- |
| 26(TERMINALS FOR EXTERNAL CONDUCTORS) |
- |
450 |
|
- |
| 27(PROVISION FOR EARTHING) |
- |
300 |
|
- |
| 28(SCREWS AND CONNECTIONS) |
- |
500 |
|
- |
| 29(CLEARANCES, CREEPAGE DISTANCES AND SOLID INSULATION) |
- |
500 |
|
- |
| 30(RESISTANCE TO HEAT AND FIRE) |
- |
500 |
|
- |
| 31(RESISTANCE TO RUSTING) |
- |
500 |
|
- |
| 32(RADIATION, TOXICITY AND SIMILAR HAZARDS) |
- |
300 |
|
- |
| 22.16(Automatic cord reel) |
- |
0 |
|
- |
| 22.32(Oxygen bomb for rubber material) |
- |
0 |
|
- |
| 22.47(Water pressure inlet) |
- |
0 |
|
- |
| 22.106(Interlocks) |
- |
0 |
|
- |
| 22.3(Flexing test) |
- |
0 |
|
- |
| 24(Components) |
- |
0 |
|
- |
| 19.11.4.1(Electrostatic discharges) |
- |
0 |
|
- |
| 19.11.4.2(Radiated fields) |
- |
0 |
|
- |
| 19.11.4.3(Fast transient bursts) |
- |
0 |
|
- |
| 19.11.4.4(Surge immunity test) |
- |
0 |
|
- |
| 19.11.4.6(Class 3 Voltage dips and interruptions) |
- |
0 |
|
- |
| 19.11.4.7(Harmonics) |
- |
0 |
|
- |
| 4(General requirements) |
- |
400 |
|
- |
| 5(General Conditions of tests) |
- |
400 |
|
- |
| 19.11.4.5(Immunity to conducted discharges) |
- |
0 |
|
- |
| 6(Classification- IS 302-1) |
- |
0 |
|
- |
| 6(Classification- IS 302-1) |
- |
0 |
|
- |
| 7.1(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.1(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.1(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.1(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.1(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.1(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.1(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.1(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.1(Marking- IS 302-2-15) |
- |
0 |
|
- |
| 7.3(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.4(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.5(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.6(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.7(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.8(Marking- IS 302-1) |
- |
0 |
|
- |
| 6(Classification- IS 302-1) |
- |
0 |
|
- |
| 6(Classification- IS 302-1) |
- |
0 |
|
- |
| 7.1(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.1(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.1(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.1(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.1(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.1(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.1(Marking- IS 302-1) |
- |
0 |
|
- |
| Marking- IS 302-1(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.1(Marking- IS 302-2-15) |
- |
0 |
|
- |
| 7.3(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.4(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.5(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.6(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.7(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.8(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.9(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.1O(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.11(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.12(Marking- IS 302-2-15) |
- |
0 |
|
- |
| 7.12(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.12.1(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.12.3(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.12.5(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.12.6(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.13(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.14(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.15(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.101(Marking- IS 302-2-15) |
- |
0 |
|
- |
| 8(Protection Against Electric Shock, IS 302-1) |
- |
0 |
|
- |
| 10(Power Input and Current, IS 302-1) |
- |
0 |
|
- |
| 11(Heating, IS 302-1) |
- |
0 |
|
- |
| 11(Heating, IS 302-1) |
- |
0 |
|
- |
| 11(Heating, IS 302-1) |
- |
0 |
|
- |
| 11(Heating, IS 302-1) |
- |
0 |
|
- |
| 13(Electrical Insulation and Leakage Current at Operating Temperature: Leakage current, IS 302-1) |
- |
0 |
|
- |
| 13(Electrical Insulation and Leakage Current at Operating Temperature: High Voltage, IS 302-1) |
- |
0 |
|
- |
| 15.1(Moisture Resistance, IS 302-1) |
- |
0 |
|
- |
| 15.2(Spillage test as 15.2, IS 3.02-1 & 302-2-15) |
- |
0 |
|
- |
| 16(Leakage current as per Cl 16, IS 302-1) |
- |
0 |
|
- |
| 16(electric strength as per Cl 16, IS 302-1) |
- |
0 |
|
- |
| 17(Overload protection of Transformers and Associated Circuits, IS 302-1) |
- |
0 |
|
- |
| 19.13(Abnormal Operation as per Cl 19, IS 302-2-15) |
- |
0 |
|
- |
| 19.13(Abnormal Operation as per Cl 19, IS 302-1) |
- |
0 |
|
- |
| 19.13(Abnormal Operation as per Cl 19, IS 302-1) |
- |
0 |
|
- |
| 19.13(Abnormal Operation as per Cl 19, IS 302-1) |
- |
0 |
|
- |
| 20.1(Stability & Mechanical Hazards, IS 302-1) |
- |
0 |
|
- |
| 21.1(Mechanical Strength, IS 302-1) |
- |
0 |
|
- |
| 21.2(Mechanical Strength, IS 302-1) |
- |
0 |
|
- |
| 22.1(Construction, IS 302-1) |
- |
0 |
|
- |
| 22.7(Construction as per Cl 22.7, IS 3.02-2-15) |
- |
0 |
|
- |
| 22.107(Construction as per Cl 22.7, IS 3.02-2-15) |
- |
0 |
|
- |
| 22.108(Construction as per Cl 22.8, IS 3.02-2-15) |
- |
0 |
|
- |
| 23.1(Internal Wiring, IS 302-1) |
- |
0 |
|
- |
| 23.2(Internal Wiring, IS 302-1) |
- |
0 |
|
- |
| 23.4(Internal Wiring, IS 302-1) |
- |
0 |
|
- |
| 23.5(Internal Wiring, IS 302-1) |
- |
0 |
|
- |
| 23.6(Internal Wiring, IS 302-1) |
- |
0 |
|
- |
| 23.7(Internal Wiring, IS 302-1) |
- |
0 |
|
- |
| 23.8(Internal Wiring, IS 302-1) |
- |
0 |
|
- |
| 23.9(Internal Wiring, IS 302-1) |
- |
0 |
|
- |
| 23.1O(Internal Wiring, IS 302-1) |
- |
0 |
|
- |
| 25.1(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
- |
| 25.2(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
- |
| 25.5(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
- |
| 25.6(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
- |
| 25.8(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
- |
| 25.9(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
- |
| 25.1(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
- |
| 25.11(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
- |
| 25.12(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
- |
| 25.13(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
- |
| 25.14(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
- |
| 25.14(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
- |
| 25.15(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
- |
| 25.16(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
- |
| 25.17(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
- |
| 25.18(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
- |
| 25.19(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
- |
| 25.2(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
- |
| 25.21(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
- |
| 25.22(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
- |
| 26(Terminals for External Conductors, IS 302-1) |
- |
0 |
|
- |
| 27.1(Provision for Earthing, IS 302-1) |
- |
0 |
|
- |
| 27.2(Provision for Earthing, IS 302-1) |
- |
0 |
|
- |
| 27.3(Provision for Earthing, IS 302-1) |
- |
0 |
|
- |
| 27.4(Provision for Earthing, IS 302-1) |
- |
0 |
|
- |
| 27.5(Provision for Earthing, IS 302-1) |
- |
0 |
|
- |
| 28(Screws & Connections, IS 302-1) |
- |
0 |
|
- |
| 29.1(Clearances, Creepage distances and Solid Insulation, IS 302-1) |
- |
0 |
|
- |
| 29.2(Clearances, Creepage distances and Solid Insulation, IS 302-1) |
- |
0 |
|
- |
| 30.1(Resistance to Heat and Fire, IS 302-1) |
- |
0 |
|
- |
| 30.2(Resistance to Heat and Fire, IS 302-1) |
- |
0 |
|
- |
| 31(Resistance of Rusting, IS 302-1) |
- |
0 |
|
- |
| Cl. 15.02(stands for cordless kettles) |
- |
0 |
|
- |
| Cl.22.103(appliance coupler of cordless kettles) |
- |
0 |
|
- |
| Cl-19.3(Abnormal operation test) |
- |
0 |
|
- |
| Cl-19.101("Abnormal operation test
") |
- |
0 |
|
- |
| Cl-19.102("Abnormal operation test
") |
- |
0 |
|
- |
| Cl-19.103("Abnormal operation test
") |
- |
0 |
|
- |
| Cl-22.103(Construction) |
- |
0 |
|
- |
| Cl-25.101(" Supply connection And external flexible ") |
- |
0 |
|
- |
|
- |
- Included w.e.f 31.12.2025
Exclusion: Cl 19.11.4.1-19.11.4.7(EMI/EMC) |
| 1459 |
Standard Testing Laboratory Private Limited
| 8170106
| IS 10238 (2001) |
Fasteners - Threaded steel fasteners - Step bolts for steel structures - Specification (First Revision) |
- |
12500 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4(GRADES) |
- |
12500 |
|
- |
| 5(MECHANICAL PROPERTIES) |
- |
12500 |
|
- |
| 6-6.1(Nuts) |
- |
12500 |
|
- |
| 6-6.2.1(Washers) |
- |
12500 |
|
- |
| 6-.6.2.2(Washers) |
- |
12500 |
|
- |
| 7(GENERAL REQUIREMENTS) |
- |
12500 |
|
- |
| 8.1(FINISH) |
- |
12500 |
|
- |
| 8.2() |
- |
12500 |
|
- |
| 8.3() |
- |
12500 |
|
- |
| 9(SAMPLING, INSPECTION AND ACCEPTANCE CRITERIA) |
- |
12500 |
|
- |
| 10.1.1(TESTS) |
- |
12500 |
|
- |
| 12(MARKING) |
- |
12500 |
|
- |
| 13(PACKAGING) |
- |
12500 |
|
- |
| Table 3 (i)(Tensile strength, Rm, MPa) |
- |
12500 |
|
- |
| Table 3 (ii)(Lower yield strength) |
- |
12500 |
|
- |
| Table 3 (iii)(Stress at 0,2 % non-proportional
elongation) |
- |
12500 |
|
- |
| table 3 (iv)(Stress at 0,0048d non-proportional
elongation for full-size fasteners) |
- |
12500 |
|
- |
| Table 3 (v)((i) Stress under proof load
(ii) Proof strength ratio) |
- |
12500 |
|
- |
| Table (vi)(Percentage elongation after fracture for
machined test pieces) |
- |
12500 |
|
- |
| Table 3 (vii)(Percentage reduction of area after
fracture for machined test pieces,) |
- |
12500 |
|
- |
| Table 3 (viii)(Elongation after fracture for full-size
fasteners,) |
- |
12500 |
|
- |
| Table 3 (ix)(Head soundness) |
- |
12500 |
|
- |
| Table 3 (x)(Vickers hardness) |
- |
12500 |
|
- |
| table 3 (xi)(Brinell hardness) |
- |
12500 |
|
- |
| table 3() |
- |
12500 |
|
- |
| table 3 (xii)(Rockwell hardness, HRB
Rockwell hardness, HRC) |
- |
12500 |
|
- |
| Table 3 (xiv)(Surface hardness) |
- |
12500 |
|
- |
| Table 3 (xv)(Height of non-decarburized thread zone,) |
- |
12500 |
|
- |
| Table 3 (xv)(Height of non-decarburized thread zone,
Depth of complete decarburization in the thread,) |
- |
12500 |
|
- |
| table 3 (xvi)(Reduction of hardness after
retempering HV) |
- |
12500 |
|
- |
| table 3 (xvii)(Breaking torque) |
- |
12500 |
|
- |
| table 3 (xviii)(Impact strength, KV) |
- |
12500 |
|
- |
| Table3 (xix)(Surface integrity in accordance with) |
- |
12500 |
|
- |
| table 3 (xvii)(Breaking torque Nm) |
- |
12500 |
|
- |
| 3(DIMENSIONS AND TOLERANCES) |
- |
12500 |
|
- |
| CL 3(Dimensions and Tolerances) |
- |
12500 |
|
- |
| CL 8(Finish) |
- |
12500 |
|
- |
| 5(Torsion test) |
- |
12500 |
|
- |
| Clause 3(Thread Requirements) |
- |
12500 |
|
- |
| Clause 11(Designation) |
- |
12500 |
|
- |
| Clause 13(Packaging) |
- |
12500 |
|
- |
| 4(GRADES) |
- |
12500 |
|
- |
| 5(MECHANICAL PROPERTIES) |
- |
12500 |
|
- |
| 6-6.1(Nuts) |
- |
12500 |
|
- |
| 6-6.2.1(Washers) |
- |
12500 |
|
- |
| 6-.6.2.2(Washers) |
- |
12500 |
|
- |
| 7(GENERAL REQUIREMENTS) |
- |
12500 |
|
- |
| 8.1(FINISH) |
- |
12500 |
|
- |
| 8.2() |
- |
12500 |
|
- |
| 8.3() |
- |
12500 |
|
- |
| 9(SAMPLING, INSPECTION AND ACCEPTANCE CRITERIA) |
- |
12500 |
|
- |
| 10.1.1(TESTS) |
- |
12500 |
|
- |
| 12(MARKING) |
- |
12500 |
|
- |
| 13(PACKAGING) |
- |
12500 |
|
- |
| Table 3 (i)(Tensile strength, Rm, MPa) |
- |
12500 |
|
- |
| Table 3 (ii)(Lower yield strength) |
- |
12500 |
|
- |
| Table 3 (iii)(Stress at 0,2 % non-proportional
elongation) |
- |
12500 |
|
- |
| table 3 (iv)(Stress at 0,0048d non-proportional
elongation for full-size fasteners) |
- |
12500 |
|
- |
| Table 3 (v)((i) Stress under proof load
(ii) Proof strength ratio) |
- |
12500 |
|
- |
| Table (vi)(Percentage elongation after fracture for
machined test pieces) |
- |
12500 |
|
- |
| Table 3 (vii)(Percentage reduction of area after
fracture for machined test pieces,) |
- |
12500 |
|
- |
| Table 3 (viii)(Elongation after fracture for full-size
fasteners,) |
- |
12500 |
|
- |
| Table 3 (ix)(Head soundness) |
- |
12500 |
|
- |
| Table 3 (x)(Vickers hardness) |
- |
12500 |
|
- |
| table 3 (xi)(Brinell hardness) |
- |
12500 |
|
- |
| table 3() |
- |
12500 |
|
- |
| table 3 (xii)(Rockwell hardness, HRB
Rockwell hardness, HRC) |
- |
12500 |
|
- |
| Table 3 (xiv)(Surface hardness) |
- |
12500 |
|
- |
| Table 3 (xv)(Height of non-decarburized thread zone,) |
- |
12500 |
|
- |
| Table 3 (xv)(Height of non-decarburized thread zone,
Depth of complete decarburization in the thread,) |
- |
12500 |
|
- |
| table 3 (xvi)(Reduction of hardness after
retempering HV) |
- |
12500 |
|
- |
| table 3 (xvii)(Breaking torque) |
- |
12500 |
|
- |
| table 3 (xviii)(Impact strength, KV) |
- |
12500 |
|
- |
| Table3 (xix)(Surface integrity in accordance with) |
- |
12500 |
|
- |
| table 3 (xvii)(Breaking torque Nm) |
- |
12500 |
|
- |
| 3(DIMENSIONS AND TOLERANCES) |
- |
12500 |
|
- |
| CL 3(Dimensions and Tolerances) |
- |
12500 |
|
- |
| CL 8(Finish) |
- |
12500 |
|
- |
| 5(Torsion test) |
- |
12500 |
|
- |
| Clause 3(Thread Requirements) |
- |
12500 |
|
- |
| Clause 11(Designation) |
- |
12500 |
|
- |
| Clause 13(Packaging) |
- |
12500 |
|
- |
|
10 Apr, 2028 |
- Included w.e.f 09.02.2026 |
| 1460 |
Perfect International Testing Lab
| 8187826
| IS 18112 (2025) |
DIGITAL TELEVISION RECEIVER FOR SATELLITE BROADCAST TRANSMISSION SPECIFICATION (First Revision) |
-- |
120000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Clause 4.4, Table-2, ii)(RF characteristics to be supported by the DTV receiver) |
- |
4000 |
|
N/A |
| Clause 4.3(Specifications) |
- |
4000 |
|
N/A |
| Clause 4.5(Safety Requirements) |
- |
3000 |
|
N/A |
| Clause 4.6(Electromagnetic Compatibility (EMC) Requirements) |
- |
0 |
|
N/A |
| Clause 5(Marking) |
- |
2000 |
|
N/A |
| Clause 6(Operating Life Test) |
- |
2000 |
|
N/A |
| Clause 4.1, Table-1, i) a)(Hardware specification) |
- |
2000 |
|
N/A |
| Clause 4.1, Table-1, i) b)(Decompression and decoding of SDTV video) |
- |
2000 |
|
N/A |
| Clause 4.1, Table-1, i) c)(Decompression and decoding of HDTV video) |
- |
2000 |
|
N/A |
| Clause 4.1, Table-1, i) d)(Decompression and decoding of audio) |
- |
2000 |
|
N/A |
| Clause 4.1, Table-1, i) e)(Active Format descriptors) |
- |
2000 |
|
N/A |
| Clause 4.1, Table-1, i) f)(Captioning and Sub-titling) |
- |
2000 |
|
N/A |
| Clause 4.1, Table-1, i) g)(Teletext) |
- |
2000 |
|
N/A |
| Clause 4.1, Table-1, i) h)(Multi-language support) |
- |
2000 |
|
N/A |
| Clause 4.1, Table-1, i) j)(DTV receiver mixed Audio Description) |
- |
3000 |
|
N/A |
| Clause 4.1, Table-1, i) k)(Broadcast mixed audio description) |
- |
2000 |
|
N/A |
| Clause 4.1, Table-1, i) m)(Service demultiplexing) |
- |
3000 |
|
N/A |
| Clause 4.1, Table-1, i) n)(Data services) |
- |
3000 |
|
N/A |
| Clause 4.1, Table-1, i) p)(OSD) |
- |
3000 |
|
N/A |
| Clause 4.1, Table-1, i) q)(DTV character set) |
- |
3000 |
|
N/A |
| Clause 4.1, Table-1, i) r)(Electronic Service Guide (ESG) ‘Now/Next’) |
- |
2000 |
|
N/A |
| Clause 4.1, Table-1, i) s)(Time) |
- |
3000 |
|
N/A |
| Clause 4.1, Table-1, i) t)(Digital TV output) |
- |
3000 |
|
N/A |
| Clause 4.4, Table-2, i) b)(Frequency) |
- |
2000 |
|
N/A |
| Clause 4.4, Table-2, i) a)(Input voltage range) |
- |
3000 |
|
N/A |
| Clause 4.1,Table-1, ii) a)(Demodulation and FEC decoding) |
- |
3000 |
|
N/A |
| Clause 4.1, Table-1, ii) b)(DTV Receiver Installation) |
- |
3000 |
|
N/A |
| Clause 4.1, Table-1, ii) c)(Network evolution) |
- |
2000 |
|
N/A |
| Clause 4.4, Table-2, iii) c)(RF input impedance) |
- |
1000 |
|
N/A |
| Clause 4.1, Table-1, ii) d)(Services available) |
- |
3000 |
|
N/A |
| Clause 4.1, Table-1, ii) e)(Selection via Service List) |
- |
2000 |
|
N/A |
| Clause 4.1, Table-1, ii) f)(Selection via Numeric Entry) |
- |
2000 |
|
N/A |
| Clause 4.1, Table-1, ii) g)(Favourite Channel list) |
- |
3000 |
|
N/A |
| Clause 4.1, Table-1, ii) h)(Hidden Services) |
- |
2000 |
|
N/A |
| Clause 4.4, Table-2, iii) b)(Input frequency range) |
- |
2000 |
|
N/A |
| Clause 4.1, Table-1, ii) j)(Logical Channel Number for Satellite services) |
- |
2000 |
|
N/A |
| Clause 4.1, Table-1, ii) k)(RF input signal) |
- |
2000 |
|
N/A |
| Clause 4.1, Table-1, ii) m)(LNB supply current) |
- |
2000 |
|
N/A |
| Clause 4.1, Table-1, ii) n)(LNB supply voltage) |
- |
2000 |
|
N/A |
| Clause 4.1, Table-1, ii) p)(LNB Control) |
- |
2000 |
|
N/A |
| Clause 4.1, Table-1, ii) q)(Modulation/Demodulation parameters for DVB-S & DVB-S2 standard) |
- |
2000 |
|
N/A |
| Clause 4.4, Table-2, iii) a)(Input level per carrier) |
- |
2000 |
|
N/A |
| Clause 4.4, Table-2, iv) c)(RF input impedance) |
- |
2000 |
|
N/A |
| Clause 4.4, Table-2, iv) b)(Input frequency range) |
- |
2000 |
|
N/A |
| Clause 4.4, Table-2, iv) a)(Input level per carrier) |
- |
2000 |
|
N/A |
| Clause 4.4, Table-2, v)(Symbol rate) |
- |
2000 |
|
N/A |
| Clause 4.4, Table-2, vi)(RF input return loss) |
- |
2000 |
|
N/A |
| Clause 4.4, Table-2, vii)(DisEqC) |
- |
2000 |
|
N/A |
| Clause 4.4, Table-2, viii)(Operating ambient temperature range) |
- |
2000 |
|
N/A |
| Clause 4.4, Table-2, ix)(Operating humidity range) |
- |
2000 |
|
N/A |
| Clause 4.1, Table-1, iii) a)(Interfaces, Connectors) |
- |
2000 |
|
N/A |
| Clause 4.1, Table-1, iv)(Automatic software upgrade mechanism) |
- |
1000 |
|
N/A |
| Clause 4.1, Table-1, v) a)(Remote Control) |
- |
1000 |
|
N/A |
| Clause 4.1, Table-1, v) b)(Easy to use and simple documentation) |
- |
1000 |
|
N/A |
| Clause 3.1, Table-1, v) c)(Support package) |
- |
1000 |
|
N/A |
|
02 Sep, 2028 |
- 1 Clause 4.6 (Electromagnetic Compatibility (EMC) Requirements) Electromagnetic Compatibility (EMC) Requirements Test facility not avaliable. |
| 1461 |
Amit Test and Calibration Centre (8172006)
| 8172006
| IS 1660 (2024) |
Wrought and Cast Aluminium Utensils Specification ( Second Revision ) |
- |
25000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl-3.1.1, 3.1.2(Minimum Thickness of Sheet) |
- |
1500 |
|
- |
| Cl-3.1.3, Table-2(Minimum Thickness at the Bottom) |
- |
1500 |
|
- |
| Cl-3.1.3, Table-2(Minimium Thickness of Wall at the Top Edge) |
- |
1500 |
|
- |
| Cl-3.1.3, Table-2(Minimum Cover Thickness) |
- |
1500 |
|
- |
| Cl-4.1(Main body of utensil) |
- |
1000 |
|
- |
| Cl-4.1(Cast cookware) |
- |
1000 |
|
- |
| Cl-4.1(Other aluminum components and parts) |
- |
1000 |
|
- |
| Cl-4.1.1(Lids (material)) |
- |
1000 |
|
- |
| Cl-4.1.1(Minimum thickness of lid) |
- |
1500 |
|
- |
| Cl-4.1.2(Minimum thickness of glass) |
- |
1500 |
|
- |
| Cl-4.1.2(Material of rim) |
- |
1000 |
|
- |
| Cl-4.1.2(Minimum thickness of rim) |
- |
1000 |
|
- |
| Cl-4.2(Material of strips) |
- |
1000 |
|
- |
| Cl-4.2(Stainless steel handles, rivets and fittings) |
- |
1000 |
|
- |
| Cl-4.3(Clips of lunch box) |
- |
1000 |
|
- |
| Cl-4.3(Clips of lunch box) |
- |
1000 |
|
- |
| Cl-4.3(Rivets used in lunch box) |
- |
1000 |
|
- |
| Cl-4.4(Screws, studs/nuts, and locking loop) |
- |
1000 |
|
- |
| Cl-4.5(Rivets for fixing of handles) |
- |
1000 |
|
- |
| Cl-4.5(Material of cap) |
- |
500 |
|
- |
| Cl-4.6(Strips used for flame guards) |
- |
1000 |
|
- |
| Cl-4.6(stainless steel) |
- |
1000 |
|
- |
| Cl-5(Fabrication) |
- |
1000 |
|
- |
| Cl-6(Shape and Dimensions) |
- |
1000 |
|
- |
| Cl-7.1(Handles, when fitted) |
- |
1000 |
|
- |
| Cl-7.2(Handles) |
- |
1000 |
|
- |
| Cl-7.3 (Cl- 4.1 of IS 13395)(Construction) |
- |
1000 |
|
- |
| Cl-7.3 (Cl- 4.2 of IS 13395)(Materials) |
- |
1000 |
|
- |
| Cl-7.3 (Cl- 4.3 of IS 13395)(Selection and Size) |
- |
1000 |
|
- |
| Cl-7.3 (Cl- 4.4 of IS 13395)(Position of Handle and Knob with Respect to Cookware) |
- |
1000 |
|
- |
| Cl-7.3 (Cl- 4.5 of IS 13395)(Attachment to Cookware) |
- |
1000 |
|
- |
| Cl-7.3 (Cl- 5.2 of IS 13395)(Bending Strength) |
- |
2500 |
|
- |
| Cl-7.3 (Cl- 5.3 of IS 13395)(Torque Strength) |
- |
2500 |
|
- |
| Cl-7.3 (Cl- 5.4 of IS 13395)(Impact Strength) |
- |
2500 |
|
- |
| Cl-7.3 (Cl- 5.5 of IS 13395)(Fatigue Resistance) |
- |
2500 |
|
- |
| Cl-7.3 (Cl- 5.6 of IS 13395)(Leakage) |
- |
2500 |
|
- |
| Cl-7.3 (Cl- 5.7 of IS 13395)(Thermal Insulation) |
- |
2500 |
|
- |
| Wrought and Cast Aluminium Utensils — Specification(Heat Resistance) |
- |
2000 |
|
- |
| Cl-7.3 (Cl- 5.9 of IS 13395)(Washing Resistance (Type Test)) |
- |
2500 |
|
- |
| Cl-7.3 (Cl- 5.10 of IS 13395)(Burning Resistance) |
- |
2500 |
|
- |
| Cl-8(Workmanship and Finish) |
- |
500 |
|
- |
| Cl-8.3(Utensils, if anodized, fully or partially) |
- |
500 |
|
- |
| Cl-8.3(Minimum nominal thickness) |
- |
1500 |
|
- |
| Cl-8.3(Thickness of hard anodized) |
- |
1500 |
|
- |
| Cl-8.3(Finish and appearance of hard anodized) |
- |
1500 |
|
- |
| Cl-8.3(Abrasion resistance of hard anodized) |
- |
1500 |
|
- |
| Cl-8.3(Colour of hard anodized) |
- |
500 |
|
- |
| Cl-8.3(Hardness of hard anodized) |
- |
1000 |
|
- |
| Wrought and Cast Aluminium Utensils — Specification(Lid of the cookware) |
- |
1000 |
|
- |
| Cl-8.5(Non-stick unreinforced PTFE) |
- |
1000 |
|
- |
| Cl-8.6(Ceramic coating) |
- |
1000 |
|
- |
| Cl-8.7(The thickness test, adhesion test) |
- |
2000 |
|
- |
| Cl-8.7(Minimum thickness of coating) |
- |
1000 |
|
- |
| Cl-8.7.1(Dry heat the cookware) |
- |
1500 |
|
- |
| Cl-8.8(Requirements of PTFE) |
- |
1000 |
|
- |
| Cl-8.9(Material for induction plate) |
- |
1000 |
|
- |
| Cl-8.9(Test for Induction compatible base) |
- |
1000 |
|
- |
| Cl-8.10.1(Tests for Lunch Boxes- Performance Test) |
- |
1500 |
|
- |
| Cl-8.10.1(Tests for Lunch Boxes- Performance Test) |
- |
1500 |
|
- |
| Cl-8.10.2(Tests for Lunch Boxes- Ground Nut Oil Test for Leakage) |
- |
1500 |
|
- |
| Cl-8.11.1(Test(s) on Tempered Glass Lid- Fragmentation Test) |
- |
1500 |
|
- |
| Cl-8.11.2(Test(s) on Tempered Glass Lid-Ball Drop Test) |
- |
1500 |
|
- |
| Cl-8.11.3(Test(s) on Tempered Glass Lid- Thermal Shock Test) |
- |
1500 |
|
- |
| Cl-8.11.4(Test(s) on Tempered Glass Lid- Free Fall Test) |
- |
1500 |
|
- |
| Cl-9.1(Normal Capacity) |
- |
1000 |
|
- |
| Cl-9.2(Normal Capacity of internal diameter) |
- |
1000 |
|
- |
| Cl 3.1.4 Table 3 (Amendment No.1)(Thickness of cast cookware- Cast Aluminium- Minimum Base Thickness of Body) |
- |
1000 |
|
- |
|
- |
- Included w.e.f. 17.02.2026 |
| 1462 |
Conformity Testing Labs Pvt. Ltd. Unit 2 (A33)
| 8139626
| IS 302 : Part 2 : Sec 42 (2024) |
Household and Similar Electrical Appliances�Safety Part 2 Particular Requirements Section 42 Commercial electric forced convection ovens, steam cookers and steam-convection ovens |
- |
250000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 7(Marking and instructions) |
- |
0 |
|
- |
| 8(Protection against access to live parts) |
- |
0 |
|
- |
| 10(Power input and current) |
- |
0 |
|
- |
| 11(Heating) |
- |
0 |
|
- |
| 13.1 &13.2(Leakage current test) |
- |
0 |
|
- |
| 13.1 &13.3(Electric strength test) |
- |
0 |
|
- |
| 14(Transient overvoltages) |
- |
0 |
|
- |
| 15.101(Moisture resistance) |
- |
0 |
|
- |
| 15(Moisture resistance) |
- |
0 |
|
- |
| 15.3(Moisture resistance) |
- |
0 |
|
- |
| 16.1 &16.2(Leakage current test) |
- |
0 |
|
- |
| 19.1 to 19.13, Table No. - 9(Abnormal operation) |
- |
0 |
|
- |
| 19.101(Abnormal operation) |
- |
0 |
|
- |
| 20.101(Stability and mechanical hazards) |
- |
0 |
|
- |
| 20.2(Stability and mechanical hazards) |
- |
0 |
|
- |
| 21(Mechanical strength) |
- |
0 |
|
- |
| 20.102(Stability and mechanical hazards) |
- |
0 |
|
- |
| 21.101(Mechanical strength) |
- |
0 |
|
- |
| 22(Construction) |
- |
0 |
|
- |
| 22.101(Construction) |
- |
0 |
|
- |
| 22.102(Construction) |
- |
0 |
|
- |
| 22.103(Construction) |
- |
0 |
|
- |
| 22.104(Construction) |
- |
0 |
|
- |
| 22.105(Construction) |
- |
0 |
|
- |
| 22.106(Construction) |
- |
0 |
|
- |
| 22.107(Construction) |
- |
0 |
|
- |
| 22.108(Construction) |
- |
0 |
|
- |
| 22.109(Construction) |
- |
0 |
|
- |
| 22.109(Construction) |
- |
0 |
|
- |
| 22.110(Construction) |
- |
0 |
|
- |
| 22.111(Construction) |
- |
0 |
|
- |
| 22.112(Construction) |
- |
0 |
|
- |
| 22.113(Construction) |
- |
0 |
|
- |
| 22.114(Construction) |
- |
0 |
|
- |
| 22.115(Construction) |
- |
0 |
|
- |
| 22.116(Construction) |
- |
0 |
|
- |
| 22.117(Construction) |
- |
0 |
|
- |
| 22.118(Construction) |
- |
0 |
|
- |
| 22.119(Construction) |
- |
0 |
|
- |
| 23(Internal wiring) |
- |
0 |
|
- |
| 24(Components) |
- |
0 |
|
- |
| 25("Supply connection and
external flexible cords") |
- |
0 |
|
- |
| 26("Terminals for external
conductors") |
- |
0 |
|
- |
| 27(Provision for earthing) |
- |
0 |
|
- |
| 28(Screws and connections) |
- |
0 |
|
- |
| 29("Clearances, creepage
distances and solid insulation") |
- |
0 |
|
- |
| 30(Resistance to heat and fire) |
- |
0 |
|
- |
| 31(Resistance to rusting) |
- |
0 |
|
- |
| 32("Radiation, toxicity and similar
hazards") |
- |
0 |
|
- |
| 16.1 & 16.3(Electric strength test) |
- |
0 |
|
- |
| 17(Overload protection of transformers and associated circuits) |
- |
0 |
|
- |
| 20.1(Stability and mechanical hazards) |
- |
0 |
|
- |
| 30.101(Resistance to heat and fire) |
- |
0 |
|
- |
|
05 Apr, 2027 |
- "1 19.101 (Abnormal operation) RADIATED FIELD TEST APPARATUS,MAINS SIGNAL TEST APPARATUS TEST FACILITY NOT AVAILABALE. |
| 1463 |
JBS TESTING SOLUTIONS PVT LTD (27), JALANDHAR
| 9164606
| IS 2603 (1983) |
Specification for copper anodes for electroplating (First Revision) |
- |
12000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl. No.2.1, Table no.1(i)("Copper ( any silver pIesent to he counted as
copper )") |
- |
6000 |
|
- |
| Cl. No.2.1,Table no.1(ii)(Bismith) |
- |
6000 |
|
- |
| Cl. No.2.1,Table no.1(iii)(Lead) |
- |
6000 |
|
- |
| Cl. No.2.1,Table no.1(iv)("Total of all impurities excluding oxygen and
silver, Max") |
- |
6000 |
|
- |
| Cl. No.3(SHAPE AND SIZE) |
- |
4000 |
|
- |
| Cl. No.4(FREEDOM FROM DEFECTS) |
- |
2000 |
|
- |
| Cl. No.5(MARKING) |
- |
2000 |
|
- |
| Cl. No.2.1, Table no.1(i)("Copper ( any silver pIesent to he counted as
copper )") |
- |
- |
|
- |
| Cl. No.2.1,Table no.1(ii)(Bismith) |
- |
- |
|
- |
| Cl. No.2.1,Table no.1(iii)(Lead) |
- |
- |
|
- |
| Cl. No.2.1,Table no.1(iv)("Total of all impurities excluding oxygen and
silver, Max") |
- |
- |
|
- |
| Cl. No.3(SHAPE AND SIZE) |
- |
- |
|
- |
| Cl. No.4(FREEDOM FROM DEFECTS) |
- |
- |
|
- |
| Cl. No.5(MARKING) |
- |
- |
|
- |
|
- |
- Included w.e.f 31.12.2025 |
| 1464 |
MIGHTY TESTING PRIVATE LIMITED, GHAZIABAD
| 8185126
| IS 302 : Part 2 : Sec 15 (2009) |
Safety of household and similar electrical appliances: Part 2 particular requirements: Sec 15 appliances for heating liquids (First Revision) |
- |
12500 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 6.0(Classification) |
- |
0 |
|
- |
| 7(Marking and instructions) |
- |
500 |
|
- |
| 8(Protection against live parts) |
- |
500 |
|
- |
| 9(STARTING OF MOTOR-OPERATED APPLIANCES) |
- |
0 |
|
- |
| 10(POWER INPUT AND CURRENT) |
- |
1000 |
|
- |
| 11(HEATING) |
- |
1000 |
|
- |
| 13(LEAKAGE CURRENT AND ELECTRIC STRENGTH AT OPERATING TEMPERATURE) |
- |
500 |
|
- |
| 14(TRANSIENT OVERVOLTAGES) |
- |
500 |
|
- |
| 15(MOISTURE RESISTANCE) |
- |
1000 |
|
- |
| 16(LEAKAGE CURRENT AND ELECTRIC STRENGTH) |
- |
500 |
|
- |
| 17(OVERLOAD PROTECTION OF TRANSFORMERS AND ASSOCIATED CIRCUITS) |
- |
500 |
|
- |
| 18(ENDURANCE) |
- |
0 |
|
- |
| 19(ABNORMAL OPERATION) |
- |
500 |
|
- |
| 20(STABILITY AND MECHANICAL HAZARDS) |
- |
500 |
|
- |
| 21(MECHANICAL STRENGTH) |
- |
500 |
|
- |
| 22(CONSTRUCTION) |
- |
500 |
|
- |
| 23(INTERNAL WIRING) |
- |
500 |
|
- |
| 24(COMPONENTS) |
- |
500 |
|
- |
| 25(SUPPLY CONNECTION AND EXTERNAL FLEXIBLE CORDS) |
- |
500 |
|
- |
| 26(TERMINALS FOR EXTERNAL CONDUCTORS) |
- |
500 |
|
- |
| 27(PROVISION FOR EARTHING) |
- |
500 |
|
- |
| 28(SCREWS AND CONNECTIONS) |
- |
500 |
|
- |
| 29(CLEARANCES, CREEPAGE DISTANCES AND SOLID INSULATION) |
- |
500 |
|
- |
| 30(RESISTANCE TO HEAT AND FIRE) |
- |
500 |
|
- |
| 31(RESISTANCE TO RUSTING) |
- |
500 |
|
- |
| 4(General requirements) |
- |
0 |
|
- |
| 5(General Conditions of tests) |
- |
0 |
|
- |
| 6(Classification- IS 302-1) |
- |
0 |
|
- |
| 6(Classification- IS 302-1) |
- |
0 |
|
- |
| 7.1(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.1(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.1(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.1(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.1(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.1(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.1(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.1(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.1(Marking- IS 302-2-15) |
- |
0 |
|
- |
| 7.3(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.4(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.5(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.6(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.7(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.8(Marking- IS 302-1) |
- |
0 |
|
- |
| 6(Classification- IS 302-1) |
- |
0 |
|
- |
| 6(Classification- IS 302-1) |
- |
0 |
|
- |
| 7.1(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.1(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.1(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.1(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.1(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.1(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.1(Marking- IS 302-1) |
- |
0 |
|
- |
| Marking- IS 302-1(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.1(Marking- IS 302-2-15) |
- |
0 |
|
- |
| 7.3(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.4(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.5(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.6(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.7(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.8(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.9(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.1O(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.11(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.12(Marking- IS 302-2-15) |
- |
0 |
|
- |
| 7.12(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.12.1(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.12.3(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.12.5(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.12.6(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.13(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.14(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.15(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.101(Marking- IS 302-2-15) |
- |
0 |
|
- |
| 8(Protection Against Electric Shock, IS 302-1) |
- |
0 |
|
- |
| 10(Power Input and Current, IS 302-1) |
- |
0 |
|
- |
| 11(Heating, IS 302-1) |
- |
0 |
|
- |
| 11(Heating, IS 302-1) |
- |
0 |
|
- |
| 11(Heating, IS 302-1) |
- |
0 |
|
- |
| 11(Heating, IS 302-1) |
- |
0 |
|
- |
| 13(Electrical Insulation and Leakage Current at Operating Temperature: Leakage current, IS 302-1) |
- |
0 |
|
- |
| 13(Electrical Insulation and Leakage Current at Operating Temperature: High Voltage, IS 302-1) |
- |
0 |
|
- |
| 15.1(Moisture Resistance, IS 302-1) |
- |
0 |
|
- |
| 15.2(Spillage test as 15.2, IS 3.02-1 & 302-2-15) |
- |
0 |
|
- |
| 16(Leakage current as per Cl 16, IS 302-1) |
- |
0 |
|
- |
| 16(electric strength as per Cl 16, IS 302-1) |
- |
0 |
|
- |
| 17(Overload protection of Transformers and Associated Circuits, IS 302-1) |
- |
0 |
|
- |
| 19.13(Abnormal Operation as per Cl 19, IS 302-2-15) |
- |
0 |
|
- |
| 19.13(Abnormal Operation as per Cl 19, IS 302-1) |
- |
0 |
|
- |
| 19.13(Abnormal Operation as per Cl 19, IS 302-1) |
- |
0 |
|
- |
| 19.13(Abnormal Operation as per Cl 19, IS 302-1) |
- |
0 |
|
- |
| 20.1(Stability & Mechanical Hazards, IS 302-1) |
- |
0 |
|
- |
| 21.1(Mechanical Strength, IS 302-1) |
- |
0 |
|
- |
| 21.2(Mechanical Strength, IS 302-1) |
- |
0 |
|
- |
| 22.1(Construction, IS 302-1) |
- |
0 |
|
- |
| 22.7(Construction as per Cl 22.7, IS 3.02-2-15) |
- |
0 |
|
- |
| 22.107(Construction as per Cl 22.7, IS 3.02-2-15) |
- |
0 |
|
- |
| 22.108(Construction as per Cl 22.8, IS 3.02-2-15) |
- |
0 |
|
- |
| 23.1(Internal Wiring, IS 302-1) |
- |
0 |
|
- |
| 23.2(Internal Wiring, IS 302-1) |
- |
0 |
|
- |
| 23.4(Internal Wiring, IS 302-1) |
- |
0 |
|
- |
| 23.5(Internal Wiring, IS 302-1) |
- |
0 |
|
- |
| 23.6(Internal Wiring, IS 302-1) |
- |
0 |
|
- |
| 23.7(Internal Wiring, IS 302-1) |
- |
0 |
|
- |
| 23.8(Internal Wiring, IS 302-1) |
- |
0 |
|
- |
| 23.9(Internal Wiring, IS 302-1) |
- |
0 |
|
- |
| 23.1O(Internal Wiring, IS 302-1) |
- |
0 |
|
- |
| 25.1(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
- |
| 25.2(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
- |
| 25.5(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
- |
| 25.6(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
- |
| 25.8(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
- |
| 25.9(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
- |
| 25.1(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
- |
| 25.11(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
- |
| 25.12(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
- |
| 25.13(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
- |
| 25.14(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
- |
| 25.14(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
- |
| 25.15(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
- |
| 25.16(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
- |
| 25.17(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
- |
| 25.18(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
- |
| 25.19(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
- |
| 25.2(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
- |
| 25.21(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
- |
| 25.22(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
- |
| Cl. 15.02(stands for cordless kettles) |
- |
0 |
|
- |
| Cl.22.103(appliance coupler of cordless kettles) |
- |
0 |
|
- |
| Cl-19.101("Abnormal operation test
") |
- |
0 |
|
- |
| Cl-19.102("Abnormal operation test
") |
- |
0 |
|
- |
| Cl-19.103("Abnormal operation test
") |
- |
0 |
|
- |
| Cl-22.103(Construction) |
- |
0 |
|
- |
| Cl-25.101(" Supply connection And external flexible ") |
- |
0 |
|
- |
| 22.47(Water pressure inlet) |
- |
0 |
|
- |
| 22.106(Interlocks) |
- |
0 |
|
- |
| 22.3(Flexing test) |
- |
0 |
|
- |
| 24(Components) |
- |
0 |
|
- |
| 26(Terminals for External Conductors, IS 302-1) |
- |
0 |
|
- |
| 27.1(Provision for Earthing, IS 302-1) |
- |
0 |
|
- |
| 27.2(Provision for Earthing, IS 302-1) |
- |
0 |
|
- |
| 27.3(Provision for Earthing, IS 302-1) |
- |
0 |
|
- |
| 27.4(Provision for Earthing, IS 302-1) |
- |
0 |
|
- |
| 27.5(Provision for Earthing, IS 302-1) |
- |
0 |
|
- |
| 28(Screws & Connections, IS 302-1) |
- |
0 |
|
- |
| 29.1(Clearances, Creepage distances and Solid Insulation, IS 302-1) |
- |
0 |
|
- |
| 29.2(Clearances, Creepage distances and Solid Insulation, IS 302-1) |
- |
0 |
|
- |
| 30.1(Resistance to Heat and Fire, IS 302-1) |
- |
0 |
|
- |
| 30.2(Resistance to Heat and Fire, IS 302-1) |
- |
0 |
|
- |
| 31(Resistance of Rusting, IS 302-1) |
- |
0 |
|
- |
| Cl-19.3(Abnormal operation test) |
- |
0 |
|
- |
| 6.0(Classification) |
- |
0 |
|
- |
| 7(Marking and instructions) |
- |
0 |
|
- |
| 8(Protection against live parts) |
- |
0 |
|
- |
| 9(STARTING OF MOTOR-OPERATED APPLIANCES) |
- |
0 |
|
- |
| 10(POWER INPUT AND CURRENT) |
- |
0 |
|
- |
| 11(HEATING) |
- |
0 |
|
- |
| 13(LEAKAGE CURRENT AND ELECTRIC STRENGTH AT OPERATING TEMPERATURE) |
- |
0 |
|
- |
| 14(TRANSIENT OVERVOLTAGES) |
- |
0 |
|
- |
| 15(MOISTURE RESISTANCE) |
- |
0 |
|
- |
| 16(LEAKAGE CURRENT AND ELECTRIC STRENGTH) |
- |
0 |
|
- |
| 17(OVERLOAD PROTECTION OF TRANSFORMERS AND ASSOCIATED CIRCUITS) |
- |
0 |
|
- |
| 18(ENDURANCE) |
- |
0 |
|
- |
| 19(ABNORMAL OPERATION) |
- |
0 |
|
- |
| 20(STABILITY AND MECHANICAL HAZARDS) |
- |
0 |
|
- |
| 21(MECHANICAL STRENGTH) |
- |
0 |
|
- |
| 22(CONSTRUCTION) |
- |
0 |
|
- |
| 23(INTERNAL WIRING) |
- |
0 |
|
- |
| 24(COMPONENTS) |
- |
0 |
|
- |
| 25(SUPPLY CONNECTION AND EXTERNAL FLEXIBLE CORDS) |
- |
0 |
|
- |
| 26(TERMINALS FOR EXTERNAL CONDUCTORS) |
- |
0 |
|
- |
| 27(PROVISION FOR EARTHING) |
- |
0 |
|
- |
| 28(SCREWS AND CONNECTIONS) |
- |
0 |
|
- |
| 29(CLEARANCES, CREEPAGE DISTANCES AND SOLID INSULATION) |
- |
0 |
|
- |
| 30(RESISTANCE TO HEAT AND FIRE) |
- |
0 |
|
- |
| 31(RESISTANCE TO RUSTING) |
- |
0 |
|
- |
| 4(General requirements) |
- |
0 |
|
- |
| 5(General Conditions of tests) |
- |
0 |
|
- |
| 6(Classification- IS 302-1) |
- |
0 |
|
- |
| 6(Classification- IS 302-1) |
- |
0 |
|
- |
| 7.1(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.1(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.1(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.1(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.1(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.1(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.1(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.1(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.1(Marking- IS 302-2-15) |
- |
0 |
|
- |
| 7.3(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.4(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.5(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.6(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.7(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.8(Marking- IS 302-1) |
- |
0 |
|
- |
| 6(Classification- IS 302-1) |
- |
0 |
|
- |
| 6(Classification- IS 302-1) |
- |
0 |
|
- |
| 7.1(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.1(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.1(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.1(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.1(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.1(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.1(Marking- IS 302-1) |
- |
0 |
|
- |
| Marking- IS 302-1(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.1(Marking- IS 302-2-15) |
- |
0 |
|
- |
| 7.3(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.4(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.5(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.6(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.7(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.8(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.9(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.1O(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.11(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.12(Marking- IS 302-2-15) |
- |
0 |
|
- |
| 7.12(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.12.1(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.12.3(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.12.5(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.12.6(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.13(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.14(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.15(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.101(Marking- IS 302-2-15) |
- |
0 |
|
- |
| 8(Protection Against Electric Shock, IS 302-1) |
- |
0 |
|
- |
| 10(Power Input and Current, IS 302-1) |
- |
0 |
|
- |
| 11(Heating, IS 302-1) |
- |
0 |
|
- |
| 11(Heating, IS 302-1) |
- |
0 |
|
- |
| 11(Heating, IS 302-1) |
- |
0 |
|
- |
| 11(Heating, IS 302-1) |
- |
0 |
|
- |
| 13(Electrical Insulation and Leakage Current at Operating Temperature: Leakage current, IS 302-1) |
- |
0 |
|
- |
| 13(Electrical Insulation and Leakage Current at Operating Temperature: High Voltage, IS 302-1) |
- |
0 |
|
- |
| 15.1(Moisture Resistance, IS 302-1) |
- |
0 |
|
- |
| 15.2(Spillage test as 15.2, IS 3.02-1 & 302-2-15) |
- |
0 |
|
- |
| 16(Leakage current as per Cl 16, IS 302-1) |
- |
0 |
|
- |
| 16(electric strength as per Cl 16, IS 302-1) |
- |
0 |
|
- |
| 17(Overload protection of Transformers and Associated Circuits, IS 302-1) |
- |
0 |
|
- |
| 19.13(Abnormal Operation as per Cl 19, IS 302-2-15) |
- |
0 |
|
- |
| 19.13(Abnormal Operation as per Cl 19, IS 302-1) |
- |
0 |
|
- |
| 19.13(Abnormal Operation as per Cl 19, IS 302-1) |
- |
0 |
|
- |
| 19.13(Abnormal Operation as per Cl 19, IS 302-1) |
- |
0 |
|
- |
| 20.1(Stability & Mechanical Hazards, IS 302-1) |
- |
0 |
|
- |
| 21.1(Mechanical Strength, IS 302-1) |
- |
0 |
|
- |
| 21.2(Mechanical Strength, IS 302-1) |
- |
0 |
|
- |
| 22.1(Construction, IS 302-1) |
- |
0 |
|
- |
| 22.7(Construction as per Cl 22.7, IS 3.02-2-15) |
- |
0 |
|
- |
| 22.107(Construction as per Cl 22.7, IS 3.02-2-15) |
- |
0 |
|
- |
| 22.108(Construction as per Cl 22.8, IS 3.02-2-15) |
- |
0 |
|
- |
| 23.1(Internal Wiring, IS 302-1) |
- |
0 |
|
- |
| 23.2(Internal Wiring, IS 302-1) |
- |
0 |
|
- |
| 23.4(Internal Wiring, IS 302-1) |
- |
0 |
|
- |
| 23.5(Internal Wiring, IS 302-1) |
- |
0 |
|
- |
| 23.6(Internal Wiring, IS 302-1) |
- |
0 |
|
- |
| 23.7(Internal Wiring, IS 302-1) |
- |
0 |
|
- |
| 23.8(Internal Wiring, IS 302-1) |
- |
0 |
|
- |
| 23.9(Internal Wiring, IS 302-1) |
- |
0 |
|
- |
| 23.1O(Internal Wiring, IS 302-1) |
- |
0 |
|
- |
| 25.1(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
- |
| 25.2(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
- |
| 25.5(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
- |
| 25.6(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
- |
| 25.8(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
- |
| 25.9(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
- |
| 25.1(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
- |
| 25.11(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
- |
| 25.12(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
- |
| 25.13(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
- |
| 25.14(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
- |
| 25.14(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
- |
| 25.15(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
- |
| 25.16(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
- |
| 25.17(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
- |
| 25.18(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
- |
| 25.19(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
- |
| 25.2(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
- |
| 25.21(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
- |
| 25.22(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
- |
| Cl. 15.02(stands for cordless kettles) |
- |
0 |
|
- |
| Cl.22.103(appliance coupler of cordless kettles) |
- |
0 |
|
- |
| Cl-19.101("Abnormal operation test
") |
- |
0 |
|
- |
| Cl-19.102("Abnormal operation test
") |
- |
0 |
|
- |
| Cl-19.103("Abnormal operation test
") |
- |
0 |
|
- |
| Cl-22.103(Construction) |
- |
0 |
|
- |
| Cl-25.101(" Supply connection And external flexible ") |
- |
0 |
|
- |
| 22.47(Water pressure inlet) |
- |
0 |
|
- |
| 22.106(Interlocks) |
- |
0 |
|
- |
| 22.3(Flexing test) |
- |
0 |
|
- |
| 24(Components) |
- |
0 |
|
- |
| 26(Terminals for External Conductors, IS 302-1) |
- |
0 |
|
- |
| 27.1(Provision for Earthing, IS 302-1) |
- |
0 |
|
- |
| 27.2(Provision for Earthing, IS 302-1) |
- |
0 |
|
- |
| 27.3(Provision for Earthing, IS 302-1) |
- |
0 |
|
- |
| 27.4(Provision for Earthing, IS 302-1) |
- |
0 |
|
- |
| 27.5(Provision for Earthing, IS 302-1) |
- |
0 |
|
- |
| 28(Screws & Connections, IS 302-1) |
- |
0 |
|
- |
| 29.1(Clearances, Creepage distances and Solid Insulation, IS 302-1) |
- |
0 |
|
- |
| 29.2(Clearances, Creepage distances and Solid Insulation, IS 302-1) |
- |
0 |
|
- |
| 30.1(Resistance to Heat and Fire, IS 302-1) |
- |
0 |
|
- |
| 30.2(Resistance to Heat and Fire, IS 302-1) |
- |
0 |
|
- |
| 31(Resistance of Rusting, IS 302-1) |
- |
0 |
|
- |
| Cl-19.3(Abnormal operation test) |
- |
0 |
|
- |
|
05 May, 2028 |
- Included w.e.f 15.01.2026
Exclusion: Cl 19.11.4.1 -19.11.4.7(EMI/EMC), 22.16 (Automatic cord reel), 22.32 (Oxygen bomb for rubber material), 32 (RADIATION, TOXICITY AND SIMILAR HAZARDS) |
| 1465 |
VERTEX TESTING LABORATORY PRIVATE LIMITED, GHAZIABAD
| 8185906
| IS 13395 (2021) |
Performance of Handles and Handle Assemblies Attached to Cookware - Specification ( First Revision ) |
All Type & size |
10100 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 1() |
- |
200 |
|
- |
| 4.1(Construction) |
- |
500 |
|
- |
| 4.2(Materials) |
- |
500 |
|
- |
| 4.3(Selection and Size) |
- |
200 |
|
- |
| 4.4(Position of handle and knob with respect to cookware) |
- |
500 |
|
- |
| 4.() |
- |
200 |
|
- |
| 4.5(Attachment to cookware) |
- |
500 |
|
- |
| 4.() |
- |
200 |
|
- |
| 5.1(General) |
- |
500 |
|
- |
| 5.2(Bending strength) |
- |
800 |
|
- |
| 5.3(Torque strength) |
- |
600 |
|
- |
| 5.4(Impact strength) |
- |
600 |
|
- |
| 5.5(Fatigue resistance) |
- |
2000 |
|
- |
| 5.6(Leakage) |
- |
500 |
|
- |
| 5.7(Thermal insulation) |
- |
500 |
|
- |
| 5.8(Heat resistance) |
- |
500 |
|
- |
| 5.9(Washing resistance) |
- |
800 |
|
- |
| 5.10(Burning resistance) |
- |
500 |
|
- |
|
23 May, 2028 |
- Included w.e.f. 30.01.2026 |
| 1466 |
Samridhi Test House Pvt. Ltd.
| 8184706
| IS 302 : Part 2 : Sec 42 (2024) |
Household and Similar Electrical Appliances�Safety Part 2 Particular Requirements Section 42 Commercial electric forced convection ovens, steam cookers and steam-convection ovens |
All Grade / Type / Size / Designation |
31000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 7(Marking and instructions) |
- |
400 |
|
- |
| 8(Protection against access to live parts) |
- |
500 |
|
- |
| 10(Power input and current) |
- |
500 |
|
- |
| 11(Heating) |
- |
500 |
|
- |
| 13.1 &13.2(Leakage current test) |
- |
500 |
|
- |
| 13.1 &13.3(Electric strength test) |
- |
500 |
|
- |
| 14(Transient overvoltages) |
- |
1100 |
|
- |
| 15(Moisture resistance) |
- |
500 |
|
- |
| 15.3(Moisture resistance) |
- |
500 |
|
- |
| 15.101(Moisture resistance) |
- |
500 |
|
- |
| 16.1 &16.2(Leakage current test) |
- |
500 |
|
- |
| 16.1 & 16.3(Electric strength test) |
- |
500 |
|
- |
| 17(Overload protection of transformers and associated circuits) |
- |
500 |
|
- |
| 19.1 to 19.13, Table No. - 9(Abnormal operation) |
- |
500 |
|
- |
| 19.101(Abnormal operation) |
- |
500 |
|
- |
| 20.1(Stability and mechanical hazards) |
- |
250 |
|
- |
| 20.2(Stability and mechanical hazards) |
- |
250 |
|
- |
| 20.101(Stability and mechanical hazards) |
- |
250 |
|
- |
| 20.102(Stability and mechanical hazards) |
- |
250 |
|
- |
| 21(Mechanical strength) |
- |
500 |
|
- |
| 21.101(Mechanical strength) |
- |
500 |
|
- |
| 22(Construction) |
- |
300 |
|
- |
| 22.101(Construction) |
- |
300 |
|
- |
| 22.102(Construction) |
- |
300 |
|
- |
| 22.103(Construction) |
- |
300 |
|
- |
| 22.104(Construction) |
- |
300 |
|
- |
| 22.105(Construction) |
- |
300 |
|
- |
| 22.106(Construction) |
- |
300 |
|
- |
| 22.107(Construction) |
- |
300 |
|
- |
| 22.108(Construction) |
- |
300 |
|
- |
| 22.109(Construction) |
- |
300 |
|
- |
| 22.109(Construction) |
- |
300 |
|
- |
| 22.110(Construction) |
- |
300 |
|
- |
| 22.111(Construction) |
- |
300 |
|
- |
| 22.112(Construction) |
- |
300 |
|
- |
| 22.113(Construction) |
- |
300 |
|
- |
| 22.114(Construction) |
- |
300 |
|
- |
| 22.115(Construction) |
- |
300 |
|
- |
| 22.116(Construction) |
- |
300 |
|
- |
| 22.117(Construction) |
- |
300 |
|
- |
| 22.118(Construction) |
- |
300 |
|
- |
| 22.119(Construction) |
- |
300 |
|
- |
| 23(Internal wiring) |
- |
1000 |
|
- |
| 24(Components) |
- |
500 |
|
- |
| 25("Supply connection and
external flexible cords") |
- |
500 |
|
- |
| 26("Terminals for external
conductors") |
- |
700 |
|
- |
| 27(Provision for earthing) |
- |
1000 |
|
- |
| 28(Screws and connections) |
- |
1500 |
|
- |
| 29("Clearances, creepage
distances and solid insulation") |
- |
1500 |
|
- |
| 30(Resistance to heat and fire) |
- |
2500 |
|
- |
| 30.101(Resistance to heat and fire) |
- |
2500 |
|
- |
| 31(Resistance to rusting) |
- |
2000 |
|
- |
| 32("Radiation, toxicity and similar
hazards") |
- |
1000 |
|
- |
| 7(Marking and instructions) |
- |
0 |
|
- |
| 8(Protection against access to live parts) |
- |
0 |
|
- |
| 10(Power input and current) |
- |
0 |
|
- |
| 11(Heating) |
- |
0 |
|
- |
| 13.1 &13.2(Leakage current test) |
- |
0 |
|
- |
| 13.1 &13.3(Electric strength test) |
- |
0 |
|
- |
| 14(Transient overvoltages) |
- |
0 |
|
- |
| 15(Moisture resistance) |
- |
0 |
|
- |
| 15.3(Moisture resistance) |
- |
0 |
|
- |
| 15.101(Moisture resistance) |
- |
0 |
|
- |
| 16.1 &16.2(Leakage current test) |
- |
0 |
|
- |
| 16.1 & 16.3(Electric strength test) |
- |
0 |
|
- |
| 17(Overload protection of transformers and associated circuits) |
- |
0 |
|
- |
| 19.1 to 19.13, Table No. - 9(Abnormal operation) |
- |
0 |
|
- |
| 19.101(Abnormal operation) |
- |
0 |
|
- |
| 20.1(Stability and mechanical hazards) |
- |
0 |
|
- |
| 20.2(Stability and mechanical hazards) |
- |
0 |
|
- |
| 20.101(Stability and mechanical hazards) |
- |
0 |
|
- |
| 20.102(Stability and mechanical hazards) |
- |
0 |
|
- |
| 21(Mechanical strength) |
- |
0 |
|
- |
| 21.101(Mechanical strength) |
- |
0 |
|
- |
| 22(Construction) |
- |
0 |
|
- |
| 22.101(Construction) |
- |
0 |
|
- |
| 22.102(Construction) |
- |
0 |
|
- |
| 22.103(Construction) |
- |
0 |
|
- |
| 22.104(Construction) |
- |
0 |
|
- |
| 22.105(Construction) |
- |
0 |
|
- |
| 22.106(Construction) |
- |
0 |
|
- |
| 22.107(Construction) |
- |
0 |
|
- |
| 22.108(Construction) |
- |
0 |
|
- |
| 22.109(Construction) |
- |
0 |
|
- |
| 22.109(Construction) |
- |
0 |
|
- |
| 22.110(Construction) |
- |
0 |
|
- |
| 22.111(Construction) |
- |
0 |
|
- |
| 22.112(Construction) |
- |
0 |
|
- |
| 22.113(Construction) |
- |
0 |
|
- |
| 22.114(Construction) |
- |
0 |
|
- |
| 22.115(Construction) |
- |
0 |
|
- |
| 22.116(Construction) |
- |
0 |
|
- |
| 22.117(Construction) |
- |
0 |
|
- |
| 22.118(Construction) |
- |
0 |
|
- |
| 22.119(Construction) |
- |
0 |
|
- |
| 23(Internal wiring) |
- |
0 |
|
- |
| 24(Components) |
- |
0 |
|
- |
| 25("Supply connection and
external flexible cords") |
- |
0 |
|
- |
| 26("Terminals for external
conductors") |
- |
0 |
|
- |
| 27(Provision for earthing) |
- |
0 |
|
- |
| 28(Screws and connections) |
- |
0 |
|
- |
| 29("Clearances, creepage
distances and solid insulation") |
- |
0 |
|
- |
| 30(Resistance to heat and fire) |
- |
0 |
|
- |
| 30.101(Resistance to heat and fire) |
- |
0 |
|
- |
| 31(Resistance to rusting) |
- |
0 |
|
- |
| 32("Radiation, toxicity and similar
hazards") |
- |
0 |
|
- |
| 7(Marking and instructions) |
- |
0 |
|
- |
| 8(Protection against access to live parts) |
- |
0 |
|
- |
| 10(Power input and current) |
- |
0 |
|
- |
| 11(Heating) |
- |
0 |
|
- |
| 13.1 &13.2(Leakage current test) |
- |
0 |
|
- |
| 13.1 &13.3(Electric strength test) |
- |
0 |
|
- |
| 14(Transient overvoltages) |
- |
0 |
|
- |
| 15(Moisture resistance) |
- |
0 |
|
- |
| 15.3(Moisture resistance) |
- |
0 |
|
- |
| 15.101(Moisture resistance) |
- |
0 |
|
- |
| 16.1 &16.2(Leakage current test) |
- |
0 |
|
- |
| 16.1 & 16.3(Electric strength test) |
- |
0 |
|
- |
| 17(Overload protection of transformers and associated circuits) |
- |
0 |
|
- |
| 19.1 to 19.13, Table No. - 9(Abnormal operation) |
- |
0 |
|
- |
| 19.101(Abnormal operation) |
- |
0 |
|
- |
| 20.1(Stability and mechanical hazards) |
- |
0 |
|
- |
| 20.2(Stability and mechanical hazards) |
- |
0 |
|
- |
| 20.101(Stability and mechanical hazards) |
- |
0 |
|
- |
| 20.102(Stability and mechanical hazards) |
- |
0 |
|
- |
| 21(Mechanical strength) |
- |
0 |
|
- |
| 21.101(Mechanical strength) |
- |
0 |
|
- |
| 22(Construction) |
- |
0 |
|
- |
| 22.101(Construction) |
- |
0 |
|
- |
| 22.102(Construction) |
- |
0 |
|
- |
| 22.103(Construction) |
- |
0 |
|
- |
| 22.104(Construction) |
- |
0 |
|
- |
| 22.105(Construction) |
- |
0 |
|
- |
| 22.106(Construction) |
- |
0 |
|
- |
| 22.107(Construction) |
- |
0 |
|
- |
| 22.108(Construction) |
- |
0 |
|
- |
| 22.109(Construction) |
- |
0 |
|
- |
| 22.109(Construction) |
- |
0 |
|
- |
| 22.110(Construction) |
- |
0 |
|
- |
| 22.111(Construction) |
- |
0 |
|
- |
| 22.112(Construction) |
- |
0 |
|
- |
| 22.113(Construction) |
- |
0 |
|
- |
| 22.114(Construction) |
- |
0 |
|
- |
| 22.115(Construction) |
- |
0 |
|
- |
| 22.116(Construction) |
- |
0 |
|
- |
| 22.117(Construction) |
- |
0 |
|
- |
| 22.118(Construction) |
- |
0 |
|
- |
| 22.119(Construction) |
- |
0 |
|
- |
| 23(Internal wiring) |
- |
0 |
|
- |
| 24(Components) |
- |
0 |
|
- |
| 25("Supply connection and
external flexible cords") |
- |
0 |
|
- |
| 26("Terminals for external
conductors") |
- |
0 |
|
- |
| 27(Provision for earthing) |
- |
0 |
|
- |
| 28(Screws and connections) |
- |
0 |
|
- |
| 29("Clearances, creepage
distances and solid insulation") |
- |
0 |
|
- |
| 30(Resistance to heat and fire) |
- |
0 |
|
- |
| 30.101(Resistance to heat and fire) |
- |
0 |
|
- |
| 31(Resistance to rusting) |
- |
0 |
|
- |
| 32("Radiation, toxicity and similar
hazards") |
- |
0 |
|
- |
|
- |
- Included w.e.f. 19.12.2025
Exclusion: 19.1 to 19.13, Table No. - 9 (Abnormal operation) |
| 1467 |
ARYAVRAT TEST HOUSE PRIVATE LIMITED
| 5191706
| IS 2062 (2011) |
Hot rolled medium and high tensile structural steel - Specification (Seventh Revision) |
All Type (Exclusion : Cl 13 Y Groove Crackability, Cl 14 Other Tests ) |
4000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl 18(Weight) |
- |
500 |
|
- |
| Cl 15(Length, Width & Thickness) |
- |
500 |
|
- |
| Cl 13(Y Groove Cracking Test) |
- |
500 |
|
- |
| Cl 12(Sudden Load Applied) |
- |
500 |
|
- |
| Cl 11.3(Press) |
- |
500 |
|
- |
| Cl 10.3(UTM) |
- |
500 |
|
- |
| Cl 7(Workmanship) |
- |
500 |
|
- |
| Cl 18(Weight) |
- |
500 |
|
- |
| Cl 15(Length, Width & Thickness) |
- |
500 |
|
- |
| Cl 13(Y Groove Cracking Test) |
- |
500 |
|
- |
| Cl 12(Sudden Load Applied) |
- |
500 |
|
- |
| Cl 11.3(Press) |
- |
500 |
|
- |
| Cl 10.3(UTM) |
- |
500 |
|
- |
| Cl 7(Workmanship) |
- |
500 |
|
- |
| Cl 18(Weight) |
- |
500 |
|
- |
| Cl 15(Length, Width & Thickness) |
- |
500 |
|
- |
| Cl 13(Y Groove Cracking Test) |
- |
500 |
|
- |
| Cl 12(Sudden Load Applied) |
- |
500 |
|
- |
| Cl 11.3(Press) |
- |
500 |
|
- |
| Cl 10.3(UTM) |
- |
500 |
|
- |
| Cl 7(Workmanship) |
- |
500 |
|
- |
| Clause - 5, 8.1 & 8.2(E650, CARBON +EQUIVELENT ) |
- |
500 |
|
- |
| Cl. 15 (Cl. 15 Channel Section: Sweep) |
- |
500 |
|
- |
| Cl. 15(Cl. 15 Channel Section: Camber) |
- |
500 |
|
- |
| Cl. 15(Cl. 15 Channel Section: Flatness of Web (Concavity)) |
- |
500 |
|
- |
| Cl. 15(Cl. 15 Channel Section: Flatness of Web (Convexity)) |
- |
500 |
|
- |
| Cl. 15(Cl. 15 Channel Section: Flange Out of Square) |
- |
500 |
|
- |
| Cl. 15(Cl. 15 Channel Section: Width of Flange) |
- |
500 |
|
- |
| Cl. 15(Cl. 15 Channel Section: Depth) |
- |
500 |
|
- |
| Cl. 15(Cl. 15 Square Bar: Out of Square) |
- |
500 |
|
- |
| Cl. 15(Cl. 15 Square Bar: Side Width: Minimum) |
- |
500 |
|
- |
| Cl. 15(Cl. 15 Square Bar: Side Width: Maximum) |
- |
500 |
|
- |
| Cl. 15(Cl. 15 Round Bar: Out of Shape) |
- |
500 |
|
- |
| Cl. 15(Cl. 15 Round Bar: Diameter Minimum) |
- |
500 |
|
- |
| Cl. 15(Cl. 15 Round Bar: Diameter Maximum) |
- |
500 |
|
- |
| Cl. 10.3 (Cl. 10.3 (Elongation %)) |
- |
500 |
|
- |
| Cl. 10.3 (Cl. 10.3 (Yield Stress)) |
- |
500 |
|
- |
| Cl. 10.3 (Cl. 10.3 (Tensile Strength)) |
- |
500 |
|
- |
| Clause - 5, 8.1 & 8.2(E650, ALUMINIUM) |
- |
500 |
|
- |
| Clause - 5, 8.1 & 8.2(E650, SILICON) |
- |
500 |
|
- |
| Clause - 5, 8.1 & 8.2(E650, NITROGEN) |
- |
500 |
|
- |
| Clause - 5, 8.1 & 8.2(E650 ,MANGANESE) |
- |
500 |
|
- |
| Clause - 5, 8.1 & 8.2(E650, PHOSPHURS) |
- |
500 |
|
- |
| Clause - 5, 8.1 & 8.2(E650, SULPHUR) |
- |
500 |
|
- |
| Clause - 5, 8.1 & 8.2(E650, CARBON) |
- |
500 |
|
- |
| Clause - 5, 8.1 & 8.2(E600, CARBON +EQUIVELENT ) |
- |
500 |
|
- |
| Clause - 5, 8.1 & 8.2(E600, ALUMINIUM) |
- |
500 |
|
- |
| Clause - 5, 8.1 & 8.2(E600, SILICON) |
- |
500 |
|
- |
| Clause - 5, 8.1 & 8.2(E600, NITROGEN) |
- |
500 |
|
- |
| Clause - 5, 8.1 & 8.2(E600 ,MANGANESE) |
- |
500 |
|
- |
| Clause - 5, 8.1 & 8.2(E600, PHOSPHURS) |
- |
500 |
|
- |
| Clause - 5, 8.1 & 8.2(E600, SULPHUR) |
- |
500 |
|
- |
| Clause - 5, 8.1 & 8.2(E600, CARBON) |
- |
500 |
|
- |
| Clause - 5, 8.1 & 8.2(E550, CARBON +EQUIVELENT ) |
- |
500 |
|
- |
| Clause - 5, 8.1 & 8.2(E550, ALUMINIUM) |
- |
500 |
|
- |
| Clause - 5, 8.1 & 8.2(E550, SILICON) |
- |
500 |
|
- |
| Clause - 5, 8.1 & 8.2(E550, NITROGEN) |
- |
500 |
|
- |
| Clause - 5, 8.1 & 8.2(E550 ,MANGANESE) |
- |
500 |
|
- |
| Clause - 5, 8.1 & 8.2(E550, PHOSPHURS) |
- |
500 |
|
- |
| Clause - 5, 8.1 & 8.2(E550, SULPHUR) |
- |
500 |
|
- |
| Clause - 5, 8.1 & 8.2(E550, CARBON) |
- |
500 |
|
- |
| Clause - 5, 8.1 & 8.2(E450, CARBON +EQUIVELENT ) |
- |
500 |
|
- |
| Clause - 5, 8.1 & 8.2(E450, ALUMINIUM) |
- |
500 |
|
- |
| Clause - 5, 8.1 & 8.2(E450, SILICON) |
- |
500 |
|
- |
| Clause - 5, 8.1 & 8.2(E450, NITROGEN) |
- |
500 |
|
- |
| Clause - 5, 8.1 & 8.2(E450 ,MANGANESE) |
- |
500 |
|
- |
| Clause - 5, 8.1 & 8.2(E450, PHOSPHURS) |
- |
500 |
|
- |
| Clause - 5, 8.1 & 8.2(E450, SULPHUR) |
- |
500 |
|
- |
| Clause - 5, 8.1 & 8.2(E450, CARBON) |
- |
500 |
|
- |
| Clause - 5, 8.1 & 8.2(E410, CARBON +EQUIVELENT ) |
- |
500 |
|
- |
| Clause - 5, 8.1 & 8.2(E410, ALUMINIUM) |
- |
500 |
|
- |
| Clause - 5, 8.1 & 8.2(E410, SILICON) |
- |
500 |
|
- |
| Clause - 5, 8.1 & 8.2(E410, NITROGEN) |
- |
500 |
|
- |
| Clause - 5, 8.1 & 8.2(E410 ,MANGANESE) |
- |
500 |
|
- |
| Clause - 5, 8.1 & 8.2(E410, PHOSPHURS) |
- |
500 |
|
- |
| Clause - 5, 8.1 & 8.2(E410, SULPHUR) |
- |
500 |
|
- |
| Clause - 5, 8.1 & 8.2(E410, CARBON) |
- |
500 |
|
- |
| Clause - 5, 8.1 & 8.2(E350, CARBON +EQUIVELENT ) |
- |
500 |
|
- |
| Clause - 5, 8.1 & 8.2(E350, ALUMINIUM) |
- |
500 |
|
- |
| Clause - 5, 8.1 & 8.2(E350, SILICON) |
- |
500 |
|
- |
| Clause - 5, 8.1 & 8.2(E350, NITROGEN) |
- |
500 |
|
- |
| Clause - 5, 8.1 & 8.2(E350 ,MANGANESE) |
- |
500 |
|
- |
| Clause - 5, 8.1 & 8.2(E350, PHOSPHURS) |
- |
500 |
|
- |
| Clause - 5, 8.1 & 8.2(E350, SULPHUR) |
- |
500 |
|
- |
| Clause - 5, 8.1 & 8.2(E350, CARBON) |
- |
500 |
|
- |
| Clause - 5, 8.1 & 8.2(E300, CARBON +EQUIVELENT ) |
- |
500 |
|
- |
| Clause - 5, 8.1 & 8.2(E300, ALUMINIUM) |
- |
500 |
|
- |
| Clause - 5, 8.1 & 8.2(E300, SILICON) |
- |
500 |
|
- |
| Clause - 5, 8.1 & 8.2(E300, NITROGEN) |
- |
500 |
|
- |
| Clause - 5, 8.1 & 8.2(E300 ,MANGANESE) |
- |
500 |
|
- |
| Clause - 5, 8.1 & 8.2(E300, PHOSPHURS) |
- |
500 |
|
- |
| Clause - 5, 8.1 & 8.2(E300, SULPHUR) |
- |
500 |
|
- |
| Clause - 5, 8.1 & 8.2(E300, CARBON) |
- |
500 |
|
- |
| Clause - 5, 8.1 & 8.2(E275, CARBON +EQUIVELENT ) |
- |
500 |
|
- |
| Clause - 5, 8.1 & 8.2(E275, ALUMINIUM) |
- |
500 |
|
- |
| Clause - 5, 8.1 & 8.2(E275, SILICON) |
- |
500 |
|
- |
| Clause - 5, 8.1 & 8.2(E275, NITROGEN) |
- |
500 |
|
- |
| Clause - 5, 8.1 & 8.2(E275 ,MANGANESE) |
- |
500 |
|
- |
| Clause - 5, 8.1 & 8.2(E275, PHOSPHURS) |
- |
500 |
|
- |
| Clause - 5, 8.1 & 8.2(E275, SULPHUR) |
- |
500 |
|
- |
| Clause - 5, 8.1 & 8.2(E275, CARBON) |
- |
500 |
|
- |
| Clause - 5, 8.1 & 8.2(E250, CARBON +EQUIVELENT ) |
- |
500 |
|
- |
| Clause - 5, 8.1 & 8.2(E250, ALUMINIUM) |
- |
500 |
|
- |
| Clause - 5, 8.1 & 8.2(E250, SILICON) |
- |
500 |
|
- |
| Clause - 5, 8.1 & 8.2(E250, NITROGEN) |
- |
500 |
|
- |
| Clause - 5, 8.1 & 8.2(E250 ,MANGANESE) |
- |
500 |
|
- |
| Clause - 5, 8.1 & 8.2(E250, PHOSPHURS) |
- |
500 |
|
- |
| Clause - 5, 8.1 & 8.2(E250, SULPHUR) |
- |
500 |
|
- |
| Clause - 5, 8.1 & 8.2(E250, CARBON) |
- |
500 |
|
- |
| Cl. 5, 8.1 ,8.2. Table 1 (Grade:- E250, E275,E300 ,E350 ,E410, E450, E550,E600, E650)(Vanadium- IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
500 |
|
- |
| Cl. 5, 8.1 ,8.2. Table 1 (Grade:- E250, E275,E300 ,E350 ,E410, E450, E550,E600, E650)(Molybdenum- IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
500 |
|
- |
| Cl. 5, 8.1 ,8.2. Table 1 (Grade:- E250, E275,E300 ,E350 ,E410, E450, E550,E600, E650)(Chromium- IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
500 |
|
- |
| Cl. 5, 8.1 ,8.2. Table 1 (Grade:- E250, E275,E300 ,E350 ,E410, E450, E550,E600, E650)(Nickel- IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
500 |
|
- |
| Cl. 5, 8.1 ,8.2. Table 1 (Grade:- E250, E275,E300 ,E350 ,E410, E450, E550,E600, E650)(Copper- IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
500 |
|
- |
| Cl. 5, 8.1 ,8.2. Table 1 (Grade:- E250, E275,E300 ,E350 ,E410, E450, E550,E600, E650)(Carbon Equivalent- IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
500 |
|
- |
| Cl. 5, 8.1 ,8.2. Table 1 (Grade:- E250, E275,E300 ,E350 ,E410, E450, E550,E600, E650)(Nitrogen- IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
500 |
|
- |
| Cl. 5, 8.1 ,8.2. Table 1 (Grade:- E250, E275,E300 ,E350 ,E410, E450, E550,E600, E650)(Silicon- IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
500 |
|
- |
| Cl. 5, 8.1 ,8.2. Table 1 (Grade:- E250, E275,E300 ,E350 ,E410, E450, E550,E600, E650)(Phosphorus- IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
500 |
|
- |
| Cl. 5, 8.1 ,8.2. Table 1 (Grade:- E250, E275,E300 ,E350 ,E410, E450, E550,E600, E650)(Sulphur- IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
500 |
|
- |
| Cl. 5, 8.1 ,8.2. Table 1 (Grade:- E250, E275,E300 ,E350 ,E410, E450, E550,E600, E650)(Manganese- IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
500 |
|
- |
| Cl. 5, 8.1 ,8.2. Table 1 (Grade:- E250, E275,E300 ,E350 ,E410, E450, E550,E600, E650)(Carbon- IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
500 |
|
- |
| Cl. 15, 16(Off Centre of Web) |
- |
500 |
|
- |
| Cl. 15, 16(Flange out of square (I beam)) |
- |
500 |
|
- |
| Cl. 15, 16(Width of flange (I Beam)) |
- |
500 |
|
- |
| Cl. 15, 16(Depth (I Beam)) |
- |
500 |
|
- |
| Cl. 15, 16(Mass (Plate)) |
- |
500 |
|
- |
| Cl. 15, 16(Flange Slope) |
- |
500 |
|
- |
| Cl. 15, 16(Web Thickness) |
- |
500 |
|
- |
| Cl. 15, 16(Flange Thickness) |
- |
500 |
|
- |
| Cl. 15, 16(Out of Square (Flat)) |
- |
500 |
|
- |
| Cl. 15, 16(Width ) |
- |
500 |
|
- |
| Cl. 15, 16(Thickness ) |
- |
500 |
|
- |
| Cl. 15, 16(Sectional Area ) |
- |
500 |
|
- |
| Cl. 15, 16(Camber (Angle)) |
- |
500 |
|
- |
| Cl. 15, 16(Out of Square (Angle)) |
- |
500 |
|
- |
| Cl. 15, 16(Weight) |
- |
500 |
|
- |
| Cl. 15, 16(Leg Length Difference (Angle)) |
- |
500 |
|
- |
| Cl. 15, 16(Leg Length B (Angle)) |
- |
500 |
|
- |
| Cl. 15, 16(Leg Length A (Angle)) |
- |
500 |
|
- |
| Cl. 15, 16(Toe Radius R2) |
- |
500 |
|
- |
| Cl. 15, 16(Root Radius R1) |
- |
500 |
|
- |
| Cl 18(Weight) |
- |
500 |
|
- |
| Cl 15(Length, Width & Thickness) |
- |
500 |
|
- |
| Cl 13(Y Groove Cracking Test) |
- |
500 |
|
- |
| Cl 12(Sudden Load Applied) |
- |
500 |
|
- |
| Cl 11.3(Press) |
- |
500 |
|
- |
| Cl 10.3(UTM) |
- |
500 |
|
- |
| Cl 7(Workmanship) |
- |
500 |
|
- |
| 14.1(Soundness test) |
- |
500 |
|
- |
| 14.2(Grain Size) |
- |
500 |
|
- |
| 14.2(Inclusion) |
- |
500 |
|
- |
| Cl 7(Workmanship) |
- |
500 |
|
- |
| Cl 10.3(UTM) |
- |
500 |
|
- |
| Cl 11.3(Press) |
- |
500 |
|
- |
| Cl 12(Sudden Load Applied) |
- |
500 |
|
- |
| Cl 13(Y Groove Cracking Test) |
- |
500 |
|
- |
| Cl 15(Length, Width & Thickness) |
- |
500 |
|
- |
| Cl 18(Weight) |
- |
500 |
|
- |
| Clause 8, Table 1, Note 2(Any Instrumental Method/Chemical Method) |
- |
500 |
|
- |
| Clause 8, Table 1, Note 5(Any Instrumental Method/Chemical Method) |
- |
500 |
|
- |
| Clause 8, Table 1, Note 5(Any Instrumental Method/Chemical Method) |
- |
500 |
|
- |
| Clause 8, Table 1, Note 5(By Calculation) |
- |
500 |
|
- |
| Clause 8, Table 1, Note 6(Any Instrumental Method/Chemical Method) |
- |
500 |
|
- |
| Clause 8, Table 1, Note 6(By Calculation) |
- |
500 |
|
- |
| Clause 7(IS 2062) |
- |
500 |
|
- |
| Clause 11.3(IS 1599) |
- |
500 |
|
- |
| Clause 12(IS 1757) |
- |
500 |
|
- |
| Clause 15, Table 4(IS 2062) |
- |
500 |
|
- |
| 16(Tolerance) |
- |
500 |
|
- |
| 20(Marking) |
- |
500 |
|
- |
| 20(MARKING) |
- |
500 |
|
- |
| 8(Micro Alloying elements) |
- |
500 |
|
- |
| 8(Niobium as Nb) |
- |
500 |
|
- |
| 8(Vanadium as V) |
- |
500 |
|
- |
| 8(Titanium as Ti) |
- |
500 |
|
- |
| 10(Tensile Strength-IS:1608(P1)-22) |
- |
500 |
|
- |
| 10(Yield Stress-IS:1608(P1)-22) |
- |
500 |
|
- |
| 10(Elongation on SoA 5.65mm GL) |
- |
500 |
|
- |
| 15(Sectional Area) |
- |
500 |
|
- |
| 15(Mass -SOP MT-23) |
- |
500 |
|
- |
| 15(Dimension -D) |
- |
500 |
|
- |
| 15(Dimension -B) |
- |
500 |
|
- |
| 15(Thickness - t) |
- |
500 |
|
- |
| 15(Thickness - T) |
- |
500 |
|
- |
| 15(Flange Slope) |
- |
500 |
|
- |
| 15(Radius R1) |
- |
500 |
|
- |
| 15(Radius R2) |
- |
500 |
|
- |
| 15(Mass -SOP MT-23) |
- |
500 |
|
- |
| 15(Sectional Area) |
- |
500 |
|
- |
| 15(Dimension -D) |
- |
500 |
|
- |
| 15(Dimension -B) |
- |
500 |
|
- |
| 15(Thickness - t) |
- |
500 |
|
- |
| 15(Thickness - T) |
- |
500 |
|
- |
| 15(Radius R1) |
- |
500 |
|
- |
| 15(Radius R2) |
- |
500 |
|
- |
| 15(Mass -SOP MT-23) |
- |
500 |
|
- |
| 15(Sectional Area) |
- |
500 |
|
- |
| 15(Dimensions AxB) |
- |
500 |
|
- |
| 15(Thickness - t) |
- |
500 |
|
- |
| 15(Radius -R1) |
- |
500 |
|
- |
| 15(Radius -R2) |
- |
500 |
|
- |
| 15(Diameter) |
- |
500 |
|
- |
| 15(Sectional Area) |
- |
500 |
|
- |
| 15(Mass per metre) |
- |
500 |
|
- |
| 15(Mass per metre) |
- |
500 |
|
- |
| 15(Ovality) |
- |
500 |
|
- |
| 15(Side Width) |
- |
500 |
|
- |
| 15(Sectional Area) |
- |
500 |
|
- |
| 15(Mass per metre) |
- |
500 |
|
- |
| 15(Out of Square) |
- |
500 |
|
- |
| 9(Preparation of test sample) |
- |
500 |
|
- |
| Clause 8, Table 1, Note 2(Aluminium) |
- |
500 |
|
- |
| Clause 8, Table 1, Note 5(Niobium) |
- |
500 |
|
- |
| Clause 8, Table 1, Note 5(Titanium) |
- |
500 |
|
- |
| Clause 8, Table 1, Note 5(Nb+V+Ti) |
- |
500 |
|
- |
| Clause 8, Table 1, Note 6(Boron) |
- |
500 |
|
- |
| Clause 8, Table 1, Note 6(Cr+Ni) |
- |
500 |
|
- |
| Clause 7(Freedom from Defect) |
- |
500 |
|
- |
| Clause 11.3(Bend Test) |
- |
500 |
|
- |
| Clause 12(Impact Test) |
- |
500 |
|
- |
| Clause 15, Table 4(Dimension) |
- |
500 |
|
- |
| 5(General Requirements) |
- |
500 |
|
- |
| 4(MARKING) |
- |
100 |
|
- |
|
28 Nov, 2028 |
- Included w.e.f 31.12.2025
"Cl 13 (Y Groove Cracking Test)
14.1 (Soundness test)" |
| 1468 |
ACCURATE TEST SOLUTIONS LLP
| 8192806
| IS 15328 (2003) |
Unplasticized Non-Pressure Polyvinyl Chloride ( PVC -U ) Pipes for use in Underground Drainage and Sewerage Systems - |
63 TO 630 |
25000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 5,5.2(Composition of the material
The material shall contain a minimum of
0.3 percent of rutile grade titanium dioxide.) |
- |
3000 |
|
- |
| 6.1,6.1.1
IS 12235 (Part 1)
Table 1(Dimension of Pipes:
Mean outside Diameter, dem) |
- |
1000 |
|
- |
| 6.1,6.1.1
IS 12235 (Part 1)
Table 1(Outside Diameter at any point, de) |
- |
1000 |
|
- |
| 6.1.2
IS 4985
Table 2(Wall Thickness, e ) |
- |
500 |
|
- |
| 6.1.3 (Length of Pipe) |
- |
1000 |
|
- |
| 6.1.4,
Table 3(Dimensions of integral sockets and spigot ends :-
a) Elastomeric Sealing Ringsockets and
spigot ends
i)Meean inside dia. Of socket, dsm) |
- |
1000 |
|
- |
| 6.1.4,
Table 3(ii) Min. depth of engagement, A. ) |
- |
1000 |
|
- |
| 6.1.4
Table 3(iii) Depth of sealing Zone C ) |
- |
1000 |
|
- |
| 6.1.4,
Table 3(iv) Length of spigot, l1) |
- |
1000 |
|
- |
| 6.1.4,
Table 3(v) Chamfer length, H : Approx.) |
- |
1000 |
|
- |
| 6.1.4.1
(wall thickness of sockets
e2 min=0.9e
) |
- |
500 |
|
- |
| 6.1.4.1
(e3min=0.75e) |
- |
500 |
|
- |
| 6.1.4,
Table 4(b) Solvent Cement Joint sockets and
spigot ends
i) Mean inside dia. Of socket, dsm) |
- |
1000 |
|
- |
| 6.1.4,
Table 4(ii) Length of Solvent Cement socket, l2 ) |
- |
1000 |
|
- |
| 6.1.4,
Table 4(iii) Length of spigot, l1, 100 mm Min.) |
- |
1000 |
|
- |
| 6.1.4,
Table 4(iv) Chamfer length, H, 7 mm Approx.) |
- |
1000 |
|
- |
| 7(Physical characteristics
) |
- |
16000 |
|
- |
| 7.1(Appearance:-
) |
- |
500 |
|
- |
| 7.1(Appearance:-
) |
- |
500 |
|
- |
| 7.2(Colour ) |
- |
500 |
|
- |
| 7.3
IS 1223S
( Part 2)(Vicat Softening Temperature
When determined according to IS 1223S
( Part 2), shall not be lessthan 79°C.) |
- |
2000 |
|
- |
| 7.4
IS 1223S ( Part 5)(Longitudinal Reversion:
When tested according to the methodprescribed in IS 1223S ( Part 5), shall not exceed ± 5 percent.
The pipe shall not exhibit any blisters, bubbles or crackson completion of the test.) |
- |
2500 |
|
- |
| 8(MECHANICAL CHARACTERISTICS) |
- |
16000 |
|
- |
| 8.1
Annex B(Resistance to External Blows at 0ºC:
When tested according to the method prescribed in Annex B, the pipes hall have a true impact rate of not more than I0 percent.) |
- |
3000 |
|
- |
| 8.2
Annex C
Table 5(Ring Stiffness:
When tested according to the method described in Annex C,the ring stiffness of the pipe shall be as stated in Table 5) |
- |
4000 |
|
- |
| 8.3
IS 12235 ( Part 8/ Sec 1 )
Table 6(Resistance to internal Hydrostatic Pressure(Type Test)
a) Acceptance Test:(1h at 27 0 C)
) |
- |
8000 |
|
- |
| 8.3
IS 12235 ( Part 8/ Sec 1 )
Table 6(b) Type Test:(1000h at 60 0 C)
) |
- |
8000 |
|
- |
| 9
9.1, IS 5382(JOINTS:-
a) Elastomeric Sealing Rings) |
- |
1000 |
|
- |
| 9.2
IS 14182(b) Solvent cement) |
- |
1000 |
|
- |
| 10(Performance requirements) |
- |
1000 |
|
- |
| 10.1.1
Annex D(Internal hydrostatic pressure test for elastomeric sealing ring joints) |
- |
10000 |
|
- |
| 10.1.2
Annex E(Internal negative hydrostatic pressure test (internal vacuum) for elastomeric sealing ring joints) |
- |
5000 |
|
- |
| 10.2.1(Internal hydrostatic pressure test for solvent cemented Joints) |
- |
8000 |
|
- |
| 10.2.2(Internal negative hydrostatic pressure test (internal vacuum)for solvent cemented joints) |
- |
10000 |
|
- |
| '7.5 (amdt.7)(Effect on Water (Type test)) |
- |
5000 |
|
- |
| 5.3(Qualitative) |
- |
1000 |
|
- |
| 12(Marking) |
- |
500 |
|
- |
| 5,5.2(Composition of the material
The material shall contain a minimum of
0.3 percent of rutile grade titanium dioxide.) |
- |
- |
|
- |
| 6.1,6.1.1
IS 12235 (Part 1)
Table 1(Dimension of Pipes:
Mean outside Diameter, dem) |
- |
- |
|
- |
| 6.1,6.1.1
IS 12235 (Part 1)
Table 1(Outside Diameter at any point, de) |
- |
- |
|
- |
| 6.1.2
IS 4985
Table 2(Wall Thickness, e ) |
- |
- |
|
- |
| 6.1.3 (Length of Pipe) |
- |
- |
|
- |
| 6.1.4,
Table 3(Dimensions of integral sockets and spigot ends :-
a) Elastomeric Sealing Ringsockets and
spigot ends
i)Meean inside dia. Of socket, dsm) |
- |
- |
|
- |
| 6.1.4,
Table 3(ii) Min. depth of engagement, A. ) |
- |
- |
|
- |
| 6.1.4
Table 3(iii) Depth of sealing Zone C ) |
- |
- |
|
- |
| 6.1.4,
Table 3(iv) Length of spigot, l1) |
- |
- |
|
- |
| 6.1.4,
Table 3(v) Chamfer length, H : Approx.) |
- |
- |
|
- |
| 6.1.4.1
(wall thickness of sockets
e2 min=0.9e
) |
- |
- |
|
- |
| 6.1.4.1
(e3min=0.75e) |
- |
- |
|
- |
| 6.1.4,
Table 4(b) Solvent Cement Joint sockets and
spigot ends
i) Mean inside dia. Of socket, dsm) |
- |
- |
|
- |
| 6.1.4,
Table 4(ii) Length of Solvent Cement socket, l2 ) |
- |
- |
|
- |
| 6.1.4,
Table 4(iii) Length of spigot, l1, 100 mm Min.) |
- |
- |
|
- |
| 6.1.4,
Table 4(iv) Chamfer length, H, 7 mm Approx.) |
- |
- |
|
- |
| 7(Physical characteristics
) |
- |
- |
|
- |
| 7.1(Appearance:-
) |
- |
- |
|
- |
| 7.1(Appearance:-
) |
- |
- |
|
- |
| 7.2(Colour ) |
- |
- |
|
- |
| 7.3
IS 1223S
( Part 2)(Vicat Softening Temperature
When determined according to IS 1223S
( Part 2), shall not be lessthan 79°C.) |
- |
- |
|
- |
| 7.4
IS 1223S ( Part 5)(Longitudinal Reversion:
When tested according to the methodprescribed in IS 1223S ( Part 5), shall not exceed ± 5 percent.
The pipe shall not exhibit any blisters, bubbles or crackson completion of the test.) |
- |
- |
|
- |
| 8(MECHANICAL CHARACTERISTICS) |
- |
- |
|
- |
| 8.1
Annex B(Resistance to External Blows at 0ºC:
When tested according to the method prescribed in Annex B, the pipes hall have a true impact rate of not more than I0 percent.) |
- |
- |
|
- |
| 8.2
Annex C
Table 5(Ring Stiffness:
When tested according to the method described in Annex C,the ring stiffness of the pipe shall be as stated in Table 5) |
- |
- |
|
- |
| 8.3
IS 12235 ( Part 8/ Sec 1 )
Table 6(Resistance to internal Hydrostatic Pressure(Type Test)
a) Acceptance Test:(1h at 27 0 C)
) |
- |
- |
|
- |
| 8.3
IS 12235 ( Part 8/ Sec 1 )
Table 6(b) Type Test:(1000h at 60 0 C)
) |
- |
- |
|
- |
| 9
9.1, IS 5382(JOINTS:-
a) Elastomeric Sealing Rings) |
- |
- |
|
- |
| 9.2
IS 14182(b) Solvent cement) |
- |
- |
|
- |
| 10(Performance requirements) |
- |
- |
|
- |
| 10.1.1
Annex D(Internal hydrostatic pressure test for elastomeric sealing ring joints) |
- |
- |
|
- |
| 10.1.2
Annex E(Internal negative hydrostatic pressure test (internal vacuum) for elastomeric sealing ring joints) |
- |
- |
|
- |
| 10.2.1(Internal hydrostatic pressure test for solvent cemented Joints) |
- |
- |
|
- |
| 10.2.2(Internal negative hydrostatic pressure test (internal vacuum)for solvent cemented joints) |
- |
- |
|
- |
| '7.5 (amdt.7)(Effect on Water (Type test)) |
- |
- |
|
- |
| 5.3(Qualitative) |
- |
- |
|
- |
| 12(Marking) |
- |
- |
|
- |
|
08 Dec, 2028 |
- included w.e.f 05.01.2026 |
| 1469 |
National Test House (WR) - NTH, Mumbai
| 7107604
| IS 6911 (2017) |
Stainless steel plate, sheet and strip - Specification (Second Revision) |
- |
22500 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl. 7.1 & 7.2 Table 1(Carbon -IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
500 |
|
- |
| Cl. 7.1 & 7.2 Table 1(Silicon -IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
500 |
|
- |
| Cl. 7.1 & 7.2 Table 1(Manganese -IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
500 |
|
- |
| Cl. 7.1 & 7.2 Table 1(Nickel -IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
500 |
|
- |
| Cl. 7.1 & 7.2 Table 1(Chromium -IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
500 |
|
- |
| Cl. 7.1 & 7.2 Table 1(Molybdenum -IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
500 |
|
- |
| Cl. 7.1 & 7.2 Table 1(Sulphur -IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
500 |
|
- |
| Cl. 7.1 & 7.2 Table 1(Phosphorus -IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
500 |
|
- |
| Cl. 7.1 & 7.2 Table 1(Nitrogen -IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
500 |
|
- |
| Cl. 7.1 & 7.2 Table 1(Copper -IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
500 |
|
- |
| Cl. 7.1 & 7.2 Table 1(Others-IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
500 |
|
- |
| Cl. 7.1 & 7.2 Table 1(Titanium-IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
500 |
|
- |
| Cl. 7.1 & 7.2 Table 1(Niobium-IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
500 |
|
- |
| Cl.12(Corrosion Resistance- IS 10461(Part1)) |
- |
10000 |
|
- |
| Cl.12(Corrosion Resistance- IS 10461(Part2)) |
- |
10000 |
|
- |
| 6(Freedom from defects , IS 6911) |
- |
1000 |
|
- |
| 10.1,Table 4&Table 6(Tensile Test - IS 1608(Pt -1)) |
- |
3000 |
|
- |
| 10.2,Table 4&Table 5(Hardness Test- IS 1500(Pt -1),IS 1501 (Pt-1),IS 1586 (Pt -1)) |
- |
1000 |
|
- |
| 10.3(Bend Test - IS 1599) |
- |
2000 |
|
- |
| 11,Table 7(Erichsen cupping test-IS 10175) |
- |
1000 |
|
- |
| 15(Surface Finish) |
- |
1000 |
|
- |
| 17(Dimension and tolerance) |
- |
1000 |
|
- |
| 10.1 Amd 2(Yeild Strength) |
- |
2000 |
|
- |
| 10.1 Amd 2(0.2 Percent Proof Stress) |
- |
2000 |
|
- |
| 10.1 Amd 2(Elongation) |
- |
2000 |
|
- |
| Clause 17 , Table 9 to Table 19(Dimension (Length)) |
- |
1000 |
|
- |
| Clause 17 , Table 9 to Table 19(Dimension (Width)) |
- |
500 |
|
- |
| Clause 17 , Table 9 to Table 19(Dimension (Thickness)) |
- |
500 |
|
- |
| Clause 17 , Table 9 to Table 19(Flatness) |
- |
1000 |
|
- |
| Clause 17 , Table 9 to Table 19(Camber) |
- |
1000 |
|
- |
| Table 1(Any Instrumental Method/Chemical Method) |
- |
1000 |
|
- |
| Table 1, Amendment 2(Any Instrumental Method/Chemical Method) |
- |
500 |
|
- |
| Table 1, Amendment 2(Any Instrumental Method/Chemical Method) |
- |
500 |
|
- |
| Table 1, Amendment 2(Any Instrumental Method/Chemical Method) |
- |
500 |
|
- |
| Table 1, Amendment 2(Any Instrumental Method/Chemical Method) |
- |
500 |
|
- |
| Table 1, Amendment 2(Any Instrumental Method/Chemical Method) |
- |
500 |
|
- |
| 10.1 Amd 2(Yeild Strength) |
- |
2000 |
|
- |
| 10.1 Amd 2(0.2 Percent Proof Stress) |
- |
2000 |
|
- |
| 10.1 Amd 2(Elongation) |
- |
2000 |
|
- |
| Clause 17 , Table 9 to Table 19(Dimension (Length)) |
- |
1000 |
|
- |
| Clause 17 , Table 9 to Table 19(Dimension (Width)) |
- |
500 |
|
- |
| Clause 17 , Table 9 to Table 19(Dimension (Thickness)) |
- |
500 |
|
- |
| Clause 17 , Table 9 to Table 19(Flatness) |
- |
1000 |
|
- |
| Clause 17 , Table 9 to Table 19(Camber) |
- |
500 |
|
- |
| Table 1, Amendment 2(Any Instrumental Method/Chemical Method) |
- |
500 |
|
- |
| Table 1, Amendment 2(Any Instrumental Method/Chemical Method) |
- |
500 |
|
- |
| Table 1, Amendment 2(Any Instrumental Method/Chemical Method) |
- |
500 |
|
- |
| Table 1, Amendment 2(Any Instrumental Method/Chemical Method) |
- |
500 |
|
- |
| Table 1, Amendment 2(Any Instrumental Method/Chemical Method) |
- |
500 |
|
- |
| 10.1 Amd 2(Yeild Strength) |
- |
500 |
|
- |
| 10.1 Amd 2(0.2 Percent Proof Stress) |
- |
2000 |
|
- |
| 10.1 Amd 2(Elongation) |
- |
2000 |
|
- |
| Clause 17 , Table 9 to Table 19(Dimension (Length)) |
- |
1000 |
|
- |
| Clause 17 , Table 9 to Table 19(Dimension (Width)) |
- |
1000 |
|
- |
| 10.1 Amd 2(Yeild Strength) |
- |
2000 |
|
- |
| 10.1 Amd 2(0.2 Percent Proof Stress) |
- |
2000 |
|
- |
| 10.1 Amd 2(Yeild Strength) |
- |
2000 |
|
- |
| 10.1 Amd 2(0.2 Percent Proof Stress) |
- |
2000 |
|
- |
| 10.1 Amd 2(Elongation) |
- |
2000 |
|
- |
| Clause 17 , Table 9 to Table 19(Dimension (Length)) |
- |
1000 |
|
- |
| Clause 17 , Table 9 to Table 19(Dimension (Width)) |
- |
500 |
|
- |
| Clause 17 , Table 9 to Table 19(Dimension (Thickness)) |
- |
1000 |
|
- |
| Clause 17 , Table 9 to Table 19(Flatness) |
- |
1000 |
|
- |
| Clause 17 , Table 9 to Table 19(Camber) |
- |
500 |
|
- |
| Table 1(Any Instrumental Method/Chemical Method) |
- |
500 |
|
- |
| Table 1, Amendment 2(Any Instrumental Method/Chemical Method) |
- |
500 |
|
- |
| Table 1, Amendment 2(Any Instrumental Method/Chemical Method) |
- |
500 |
|
- |
| Table 1, Amendment 2(Any Instrumental Method/Chemical Method) |
- |
500 |
|
- |
| Table 1, Amendment 2(Any Instrumental Method/Chemical Method) |
- |
500 |
|
- |
| Table 1, Amendment 2(Any Instrumental Method/Chemical Method) |
- |
500 |
|
- |
| Table 1, Amendment 2(Any Instrumental Method/Chemical Method) |
- |
500 |
|
- |
| 4(Supply of Material) |
- |
1000 |
|
- |
| 8(Heat Treatment) |
- |
2000 |
|
- |
| 19(Marking) |
- |
1000 |
|
- |
| 5(Manufacture) |
- |
1000 |
|
- |
| 10.1 Amd 2(Yeild Strength) |
- |
2000 |
|
- |
| 10.1 Amd 2(0.2 Percent Proof Stress) |
- |
2000 |
|
- |
| 10.1 Amd 2(Elongation) |
- |
2000 |
|
- |
| Clause 17 , Table 9 to Table 19(Dimension (Length)) |
- |
1000 |
|
- |
| Clause 17 , Table 9 to Table 19(Dimension (Width)) |
- |
500 |
|
- |
| Clause 17 , Table 9 to Table 19(Dimension (Thickness)) |
- |
1000 |
|
- |
| Clause 17 , Table 9 to Table 19(Flatness) |
- |
1000 |
|
- |
| Clause 17 , Table 9 to Table 19(Camber) |
- |
500 |
|
- |
| Table 1(Alumium) |
- |
500 |
|
- |
| Table 1, Amendment 2(Zirconium) |
- |
500 |
|
- |
| Table 1, Amendment 2(Tungstun) |
- |
500 |
|
- |
| Table 1, Amendment 2(Tungstun) |
- |
500 |
|
- |
| Table 1, Amendment 2(Ce) |
- |
500 |
|
- |
| Table 1, Amendment 2(Cobalt) |
- |
500 |
|
- |
| Table 1, Amendment 2(Ta) |
- |
500 |
|
- |
| 5.1 - 1(Carbon) |
- |
500 |
|
- |
| 5.1 - 1(Sulphur) |
- |
500 |
|
- |
| 5.1 - 1(Phosphorus) |
- |
500 |
|
- |
| 5.1 - 1(Manganese) |
- |
500 |
|
- |
| 5.1 - 1(Silicon) |
- |
500 |
|
- |
| 5.1 - 1(Nitrogen) |
- |
500 |
|
- |
| 5.1 - 1(Copper) |
- |
500 |
|
- |
| 5.1 - 1(Titanium) |
- |
500 |
|
- |
| 5.1 - 1(Aluminium) |
- |
500 |
|
- |
| 5.1 - 1(Niobium) |
- |
500 |
|
- |
| 5.1 - 1(Nickel) |
- |
500 |
|
- |
| 5.1 - 1(Chromium) |
- |
500 |
|
- |
| 5.1 - 1(Molybdenum) |
- |
500 |
|
- |
| 6(Freedom from defect) |
- |
1000 |
|
- |
| 10.1 - 4(Tensile Test) |
- |
2000 |
|
- |
| 10.1 - 4(Yield strength) |
- |
2000 |
|
- |
| 10.1 - 4(Elongation % on 50mm) |
- |
2000 |
|
- |
| 10.2(Hardness Test) |
- |
2000 |
|
- |
| 10.3(Bend Test) |
- |
2000 |
|
- |
| 11(Erichsen Cupping Test) |
- |
1500 |
|
- |
| 17(Dimension and tolerance) |
- |
1000 |
|
- |
| 12(Corrosion resistance) |
- |
10000 |
|
- |
| 5.1 - 1(Carbon) |
- |
500 |
|
- |
| 5.1 - 1(Sulphur) |
- |
500 |
|
- |
| 5.1 - 1(Phosphorus) |
- |
500 |
|
- |
| 5.1 - 1(Manganese) |
- |
500 |
|
- |
| 5.1 - 1(Silicon) |
- |
500 |
|
- |
| 5.1 - 1(Nitrogen) |
- |
500 |
|
- |
| 5.1 - 1(Copper) |
- |
500 |
|
- |
| 5.1 - 1(Titanium) |
- |
500 |
|
- |
| 5.1 - 1(Aluminium) |
- |
500 |
|
- |
| 5.1 - 1(Niobium) |
- |
500 |
|
- |
| 5.1 - 1(Chromium) |
- |
500 |
|
- |
| 5.1 - 1(Molybdenum) |
- |
500 |
|
- |
| 6(Freedom from defect) |
- |
500 |
|
- |
| 10.1 - 4(Tensile Test) |
- |
2000 |
|
- |
| 10.1 - 4(Yield strength) |
- |
2000 |
|
- |
| 10.1 - 4(Elongation % on 50mm) |
- |
2000 |
|
- |
| 10.2(Hardness Test) |
- |
2000 |
|
- |
| 10.3(Bend Test) |
- |
2000 |
|
- |
| 11(Erichsen Cupping Test) |
- |
1500 |
|
- |
| 17(Dimension and tolerance) |
- |
1000 |
|
- |
| 12(Corrosion resistance) |
- |
10000 |
|
- |
| Table 1(Any Instrumental Method/Chemical Method) |
- |
500 |
|
- |
| 5.1 - 1(Nickel) |
- |
500 |
|
- |
|
24 Jul, 2025 |
- Included w.e.f 16.12.2025 |
| 1470 |
ACCURATE TEST SOLUTIONS LLP
| 8192806
| IS 13487 (2024) |
Irrigation Equipment — Emitters — Specification |
All Variety |
7000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl-5.1(Connections) |
- |
500 |
|
- |
| Cl-5.2(Emitter Ends) |
- |
500 |
|
- |
| Cl-5.3(Materials) |
- |
4000 |
|
- |
| Cl-6.1(Test Specimens) |
- |
500 |
|
- |
| Cl-6.2.1(polyethylene pipe) |
- |
500 |
|
- |
| Cl-6.2.2("grease or chemicals
") |
- |
500 |
|
- |
| Cl-6.2.3(water temperature) |
- |
500 |
|
- |
| Cl-6.3(Accuracy or Measuring Devices) |
- |
500 |
|
- |
| Cl-7.1(Construction and Workmanship) |
- |
1000 |
|
- |
| Cl-7.2(Flow Paths in Emitter) |
- |
1000 |
|
- |
| Cl-7.3(Resistance to Hydrostatic Pressure) |
- |
3000 |
|
- |
| Cl-7.4(Emitter Pull-Out) |
- |
2000 |
|
- |
| Cl-7.4.1(In-Line Emitters) |
- |
4000 |
|
- |
| Cl-7.4.2(On-Line Emitters) |
- |
4000 |
|
- |
| Cl-8.1.1(Uniformity of Emission Rate) |
- |
3000 |
|
- |
| Cl-8.1.2(Emission Rate as Function of Inlet Pressure) |
- |
3000 |
|
- |
| Cl-8.1.3(Determination of Emitter Exponent) |
- |
3000 |
|
- |
| Cl-9(Marking) |
- |
500 |
|
- |
|
08 Dec, 2028 |
- Included w.e.f. 27.01.2026 |