| 1831 |
EKO PRO ENGINEERS PRIVATE LIMITED (32/37) GHAZIABAD
| 8164006
| IS 206 (2010) |
Tee and strap hinges - Specification (Fifth Revision) |
All Grade |
7500 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 5(DIMENSIONS AND TOLERANCES) |
- |
2500 |
|
- |
| 6(WORKMANSHIP) |
- |
2500 |
|
- |
| 7(FINISH) |
- |
0 |
|
- |
| 10(MARKING) |
- |
0 |
|
- |
| Clause 3.1,1(Light weight
(Type 1)) |
- |
2500 |
|
- |
| Clause 3.1,2(Light weight
(Type 2)) |
- |
2500 |
|
- |
| Clause 3.1,3(Medium weight
(Type 1)) |
- |
2500 |
|
- |
| Clause 3.1,4(Medium weight
(Type 2)) |
- |
2500 |
|
- |
| Clause 3.1,5(Heavy weight
(Type 1)) |
- |
2500 |
|
- |
| Clause 3.1,6(Heavy weight
(Type 2)) |
- |
2500 |
|
- |
| Clause 3.1,7(Heavy weight
(Type 3)) |
- |
2500 |
|
- |
| Clause 3.2,1(Light weight) |
- |
2500 |
|
- |
| Clause 3.2,2(Medium weight
(Type 1)) |
- |
2500 |
|
- |
| Clause 3.2,3(Medium weight
(Type 2)) |
- |
2500 |
|
- |
| Clause 3.2,4(Heavy weight ) |
- |
2500 |
|
- |
| Clause 4
Table 1(i)(Mild steel sheet) |
- |
5000 |
|
- |
| Clause 4
Table 1(ii)(Mild steel wire) |
- |
5000 |
|
- |
| Clause 5.1(Dimensions) |
- |
2500 |
|
- |
| Clause 6(Workmanship) |
- |
0 |
|
- |
| Clause 8(Packing) |
- |
0 |
|
- |
| Clause 9(SAMPLING AND CRITERION FOR CONFORMITY) |
- |
0 |
|
- |
| Clause 10(Marking) |
- |
0 |
|
- |
|
27 May, 2028 |
- INCLUDED W.E.F.16.09.2025 |
| 1832 |
Intertek India Private Limited, New Delhi (E-26)
| 8136626
| IS 18112 (2025) |
DIGITAL TELEVISION RECEIVER FOR SATELLITE BROADCAST TRANSMISSION SPECIFICATION (First Revision) |
- |
318000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Clause 4.4, Table-2, ii)(RF characteristics to be supported by the DTV receiver) |
- |
10000 |
|
10% discount offered to samples received from BIS. |
| Clause 4.3(Specifications) |
- |
5000 |
|
10% discount offered to samples received from BIS. |
| Clause 4.5(Safety Requirements) |
- |
126000 |
|
10% discount offered to samples received from BIS. |
| Clause 5(Marking) |
- |
2000 |
|
10% discount offered to samples received from BIS. |
| Clause 6(Operating Life Test) |
- |
20000 |
|
10% discount offered to samples received from BIS. |
| Clause 4.1, Table-1, i) a)(Hardware specification) |
- |
3000 |
|
10% discount offered to samples received from BIS. |
| Clause 4.1, Table-1, i) b)(Decompression and decoding of SDTV video) |
- |
5000 |
|
10% discount offered to samples received from BIS. |
| Clause 4.1, Table-1, i) c)(Decompression and decoding of HDTV video) |
- |
5000 |
|
10% discount offered to samples received from BIS. |
| Clause 4.1, Table-1, i) d)(Decompression and decoding of audio) |
- |
5000 |
|
10% discount offered to samples received from BIS. |
| Clause 4.1, Table-1, i) e)(Active Format descriptors) |
- |
5000 |
|
10% discount offered to samples received from BIS. |
| Clause 4.1, Table-1, i) f)(Captioning and Sub-titling) |
- |
5000 |
|
10% discount offered to samples received from BIS. |
| Clause 4.1, Table-1, i) g)(Teletext) |
- |
2000 |
|
10% discount offered to samples received from BIS. |
| Clause 4.1, Table-1, i) h)(Multi-language support) |
- |
2000 |
|
10% discount offered to samples received from BIS. |
| Clause 4.1, Table-1, i) j)(DTV receiver mixed Audio Description) |
- |
5000 |
|
10% discount offered to samples received from BIS. |
| Clause 4.1, Table-1, i) k)(Broadcast mixed audio description) |
- |
5000 |
|
10% discount offered to samples received from BIS. |
| Clause 4.1, Table-1, i) m)(Service demultiplexing) |
- |
5000 |
|
10% discount offered to samples received from BIS. |
| Clause 4.1, Table-1, i) n)(Data services) |
- |
5000 |
|
10% discount offered to samples received from BIS. |
| Clause 4.1, Table-1, i) p)(OSD) |
- |
5000 |
|
10% discount offered to samples received from BIS. |
| Clause 4.1, Table-1, i) q)(DTV character set) |
- |
5000 |
|
10% discount offered to samples received from BIS. |
| Clause 4.1, Table-1, i) r)(Electronic Service Guide (ESG) ‘Now/Next’) |
- |
5000 |
|
10% discount offered to samples received from BIS. |
| Clause 4.1, Table-1, i) s)(Time) |
- |
1000 |
|
10% discount offered to samples received from BIS. |
| Clause 4.1, Table-1, i) t)(Digital TV output) |
- |
2000 |
|
10% discount offered to samples received from BIS. |
| Clause 4.4, Table-2, i) b)(Frequency) |
- |
1000 |
|
10% discount offered to samples received from BIS. |
| Clause 4.4, Table-2, i) a)(Input voltage range) |
- |
1000 |
|
10% discount offered to samples received from BIS. |
| Clause 4.1,Table-1, ii) a)(Demodulation and FEC decoding) |
- |
5000 |
|
10% discount offered to samples received from BIS. |
| Clause 4.1, Table-1, ii) b)(DTV Receiver Installation) |
- |
2000 |
|
10% discount offered to samples received from BIS. |
| Clause 4.1, Table-1, ii) c)(Network evolution) |
- |
2000 |
|
10% discount offered to samples received from BIS. |
| Clause 4.4, Table-2, iii) c)(RF input impedance) |
- |
5000 |
|
10% discount offered to samples received from BIS. |
| Clause 4.1, Table-1, ii) d)(Services available) |
- |
2000 |
|
10% discount offered to samples received from BIS. |
| Clause 4.1, Table-1, ii) e)(Selection via Service List) |
- |
2000 |
|
10% discount offered to samples received from BIS. |
| Clause 4.1, Table-1, ii) f)(Selection via Numeric Entry) |
- |
2000 |
|
10% discount offered to samples received from BIS. |
| Clause 4.1, Table-1, ii) g)(Favourite Channel list) |
- |
1000 |
|
10% discount offered to samples received from BIS. |
| Clause 4.1, Table-1, ii) h)(Hidden Services) |
- |
2000 |
|
10% discount offered to samples received from BIS. |
| Clause 4.4, Table-2, iii) b)(Input frequency range) |
- |
5000 |
|
10% discount offered to samples received from BIS. |
| Clause 4.1, Table-1, ii) j)(Logical Channel Number for Satellite services) |
- |
2000 |
|
10% discount offered to samples received from BIS. |
| Clause 4.1, Table-1, ii) k)(RF input signal) |
- |
3000 |
|
10% discount offered to samples received from BIS. |
| Clause 4.1, Table-1, ii) m)(LNB supply current) |
- |
5000 |
|
10% discount offered to samples received from BIS. |
| Clause 4.1, Table-1, ii) n)(LNB supply voltage) |
- |
3000 |
|
10% discount offered to samples received from BIS. |
| Clause 4.1, Table-1, ii) p)(LNB Control) |
- |
2000 |
|
10% discount offered to samples received from BIS. |
| Clause 4.1, Table-1, ii) q)(Modulation/Demodulation parameters for DVB-S & DVB-S2 standard) |
- |
2000 |
|
10% discount offered to samples received from BIS. |
| Clause 4.4, Table-2, iii) a)(Input level per carrier) |
- |
5000 |
|
10% discount offered to samples received from BIS. |
| Clause 4.4, Table-2, iv) c)(RF input impedance) |
- |
5000 |
|
10% discount offered to samples received from BIS. |
| Clause 4.4, Table-2, iv) b)(Input frequency range) |
- |
5000 |
|
10% discount offered to samples received from BIS. |
| Clause 4.4, Table-2, iv) a)(Input level per carrier) |
- |
5000 |
|
10% discount offered to samples received from BIS. |
| Clause 4.4, Table-2, v)(Symbol rate) |
- |
5000 |
|
10% discount offered to samples received from BIS. |
| Clause 4.4, Table-2, vi)(RF input return loss) |
- |
5000 |
|
10% discount offered to samples received from BIS. |
| Clause 4.4, Table-2, vii)(DisEqC) |
- |
2000 |
|
10% discount offered to samples received from BIS. |
| Clause 4.4, Table-2, viii)(Operating ambient temperature range) |
- |
1000 |
|
10% discount offered to samples received from BIS. |
| Clause 4.4, Table-2, ix)(Operating humidity range) |
- |
1000 |
|
10% discount offered to samples received from BIS. |
| Clause 4.1, Table-1, iii) a)(Interfaces, Connectors) |
- |
1000 |
|
10% discount offered to samples received from BIS. |
| Clause 4.1, Table-1, iv)(Automatic software upgrade mechanism) |
- |
1000 |
|
10% discount offered to samples received from BIS. |
| Clause 4.1, Table-1, v) a)(Remote Control) |
- |
1000 |
|
10% discount offered to samples received from BIS. |
| Clause 4.1, Table-1, v) b)(Easy to use and simple documentation) |
- |
1000 |
|
10% discount offered to samples received from BIS. |
| Clause 3.1, Table-1, v) c)(Support package) |
- |
1000 |
|
10% discount offered to samples received from BIS. |
| Clause 4.4, Table-2, ii)(RF characteristics to be supported by the DTV receiver) |
- |
- |
|
- |
| Clause 4.3(Specifications) |
- |
- |
|
- |
| Clause 4.5(Safety Requirements) |
- |
- |
|
- |
| Clause 5(Marking) |
- |
- |
|
- |
| Clause 6(Operating Life Test) |
- |
- |
|
- |
| Clause 4.1, Table-1, i) a)(Hardware specification) |
- |
- |
|
- |
| Clause 4.1, Table-1, i) b)(Decompression and decoding of SDTV video) |
- |
- |
|
- |
| Clause 4.1, Table-1, i) c)(Decompression and decoding of HDTV video) |
- |
- |
|
- |
| Clause 4.1, Table-1, i) d)(Decompression and decoding of audio) |
- |
- |
|
- |
| Clause 4.1, Table-1, i) e)(Active Format descriptors) |
- |
- |
|
- |
| Clause 4.1, Table-1, i) f)(Captioning and Sub-titling) |
- |
- |
|
- |
| Clause 4.1, Table-1, i) g)(Teletext) |
- |
- |
|
- |
| Clause 4.1, Table-1, i) h)(Multi-language support) |
- |
- |
|
- |
| Clause 4.1, Table-1, i) j)(DTV receiver mixed Audio Description) |
- |
- |
|
- |
| Clause 4.1, Table-1, i) k)(Broadcast mixed audio description) |
- |
- |
|
- |
| Clause 4.1, Table-1, i) m)(Service demultiplexing) |
- |
- |
|
- |
| Clause 4.1, Table-1, i) n)(Data services) |
- |
- |
|
- |
| Clause 4.1, Table-1, i) p)(OSD) |
- |
- |
|
- |
| Clause 4.1, Table-1, i) q)(DTV character set) |
- |
- |
|
- |
| Clause 4.1, Table-1, i) r)(Electronic Service Guide (ESG) ‘Now/Next’) |
- |
- |
|
- |
| Clause 4.1, Table-1, i) s)(Time) |
- |
- |
|
- |
| Clause 4.1, Table-1, i) t)(Digital TV output) |
- |
- |
|
- |
| Clause 4.4, Table-2, i) b)(Frequency) |
- |
- |
|
- |
| Clause 4.4, Table-2, i) a)(Input voltage range) |
- |
- |
|
- |
| Clause 4.1,Table-1, ii) a)(Demodulation and FEC decoding) |
- |
- |
|
- |
| Clause 4.1, Table-1, ii) b)(DTV Receiver Installation) |
- |
- |
|
- |
| Clause 4.1, Table-1, ii) c)(Network evolution) |
- |
- |
|
- |
| Clause 4.4, Table-2, iii) c)(RF input impedance) |
- |
- |
|
- |
| Clause 4.1, Table-1, ii) d)(Services available) |
- |
- |
|
- |
| Clause 4.1, Table-1, ii) e)(Selection via Service List) |
- |
- |
|
- |
| Clause 4.1, Table-1, ii) f)(Selection via Numeric Entry) |
- |
- |
|
- |
| Clause 4.1, Table-1, ii) g)(Favourite Channel list) |
- |
- |
|
- |
| Clause 4.1, Table-1, ii) h)(Hidden Services) |
- |
- |
|
- |
| Clause 4.4, Table-2, iii) b)(Input frequency range) |
- |
- |
|
- |
| Clause 4.1, Table-1, ii) j)(Logical Channel Number for Satellite services) |
- |
- |
|
- |
| Clause 4.1, Table-1, ii) k)(RF input signal) |
- |
- |
|
- |
| Clause 4.1, Table-1, ii) m)(LNB supply current) |
- |
- |
|
- |
| Clause 4.1, Table-1, ii) n)(LNB supply voltage) |
- |
- |
|
- |
| Clause 4.1, Table-1, ii) p)(LNB Control) |
- |
- |
|
- |
| Clause 4.1, Table-1, ii) q)(Modulation/Demodulation parameters for DVB-S & DVB-S2 standard) |
- |
- |
|
- |
| Clause 4.4, Table-2, iii) a)(Input level per carrier) |
- |
- |
|
- |
| Clause 4.4, Table-2, iv) c)(RF input impedance) |
- |
- |
|
- |
| Clause 4.4, Table-2, iv) b)(Input frequency range) |
- |
- |
|
- |
| Clause 4.4, Table-2, iv) a)(Input level per carrier) |
- |
- |
|
- |
| Clause 4.4, Table-2, v)(Symbol rate) |
- |
- |
|
- |
| Clause 4.4, Table-2, vi)(RF input return loss) |
- |
- |
|
- |
| Clause 4.4, Table-2, vii)(DisEqC) |
- |
- |
|
- |
| Clause 4.4, Table-2, viii)(Operating ambient temperature range) |
- |
- |
|
- |
| Clause 4.4, Table-2, ix)(Operating humidity range) |
- |
- |
|
- |
| Clause 4.1, Table-1, iii) a)(Interfaces, Connectors) |
- |
- |
|
- |
| Clause 4.1, Table-1, iv)(Automatic software upgrade mechanism) |
- |
- |
|
- |
| Clause 4.1, Table-1, v) a)(Remote Control) |
- |
- |
|
- |
| Clause 4.1, Table-1, v) b)(Easy to use and simple documentation) |
- |
- |
|
- |
| Clause 3.1, Table-1, v) c)(Support package) |
- |
- |
|
- |
|
27 Apr, 2029 |
- Included w.e.f. 10.10.2025
Exclusion: Cl.4.6 (Electromagnetic Compatibility (EMC) Requirement) |
| 1833 |
Central Institute of Petrochemicals Engineering & Technology (CIPET), Murthal
| 9121934
| IS 9755 (2021) |
Textiles - High Density Polyethylene (HDPE) / Polypropylene (pp) Woven Sacks for Packing Fertilizers |
Type- I II |
40130 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4.1(Raw Meterial) |
- |
4200 |
|
Identification-2000
Migration-1700
Specimen Charges-500 |
| 4.2("Fabric
a) Width of Tape") |
- |
500 |
|
- |
| 4.2("Fabric
b) Linear Density") |
- |
700 |
|
- |
| 4.2("Fabric
c) Mesh") |
- |
500 |
|
- |
| 4.2("Fabric
c) Mesh") |
- |
500 |
|
- |
| 4.2("Fabric
d) Unlaminated Fabric Mass") |
- |
500 |
|
- |
| 4.3(Sacks) |
- |
500 |
|
- |
| 4.4.1(Loose Liner) |
- |
2000 |
|
Identification |
| 4.4.1(Thickness of Linear) |
- |
500 |
|
- |
| 4.4.2(Visual Observation) |
- |
500 |
|
- |
| 4.4.3(Bottom Seam of Loose Liner) |
- |
500 |
|
- |
| 4.5(Mass of The Lamination) |
- |
500 |
|
- |
| 4.5(Laminated Fabric) |
- |
2000 |
|
Identification |
| 4.5(Lamination Over Hang of the fabric after trimming) |
- |
500 |
|
- |
| 5.6(Drop Impact Test) |
- |
850 |
|
- |
| 4.6.1(Distance between the Two Row of Stitches) |
- |
500 |
|
- |
| 4.6.1(Distance of outer stitch from the edge of the bag) |
- |
0 |
|
- |
| 4.6.1(Depth of the Stitch( Double fold)) |
- |
0 |
|
- |
| 4.6.1(No.of Stitches/dm) |
- |
0 |
|
- |
| 4.6.2(Breaking Load of the stitching material Non UV Stabilized sack) |
- |
1100 |
|
- |
| 4.6.2(Breaking Load for UV Stabilized sack) |
- |
1100 |
|
- |
| 4.7(Mouth of the Sack) |
- |
500 |
|
- |
| "Table 1 of Cl. No.5.1 Sl. No. i"("Dimension
a) Inside Length Type 1 & Type 2
") |
- |
500 |
|
- |
| "Table 1 of Cl. No.5.1 Sl. No. i"("Dimension
b) Inside Width ") |
- |
0 |
|
- |
| "Table 1 of Cl. No.5.1 Sl. No. ii"(Ends/dm ( Type 1 & Type 2)) |
- |
500 |
|
- |
| "Table 1 of Cl. No.5.1 Sl. No. iii"(Picks /dm ( Type 1 & Type 2)) |
- |
500 |
|
- |
| "Table 1 of Cl. No.5.3 Sl. No. iv"("Mass of Fabric
a) Unlaminated Sack( Type 1 & Type 2)") |
- |
500 |
|
- |
| "Table 1 of Cl. No.5.3 Sl. No. iv"("Mass of Fabric
b) Laminated Sack( Type 1 & Type 2)") |
- |
500 |
|
- |
| "Table 1 of Cl. No.5.3 Sl. No. v"(Mass of Sack( Type 1 & Type 2)) |
- |
500 |
|
- |
| "Table 1 of Cl. No.5.4 Sl. No. vi"(Avg. Breaking Strength Of fabric (Ravelled strip method)( 325mm X 25 mm)) |
- |
2700 |
|
Length Wise-1100
Width Wise-1100
Specimen Charges-500 |
| "Table 1 of Cl. No.5.4 Sl. No. vii"(Breaking Strength of Bottom Seam (Ravelled strip method)) |
- |
1100 |
|
- |
| "Table 1 of Cl. No.5.1 Sl. No. viii"("Elongation at Break of fabric
a)Length(Type 1 & Type 2)") |
- |
0 |
|
- |
| "Table 1 of Cl. No.5.1 Sl. No. viii"("Elongation at Break of fabric
b) Width(Type 1 & Type 2)") |
- |
0 |
|
- |
| "Table 1 of Cl. No.5.5 Sl. No. ix"("Ash Content
a) For UV Stabilized Sack") |
- |
1200 |
|
- |
| "Table 1 of Cl. No.5.5 Sl. No. ix"("Ash Content
b) For Non- UV Stabilized Sack") |
- |
1200 |
|
- |
| "Table 1 of Cl. No.5.6 Sl. No. x"(Drop Impact Strength) |
- |
850 |
|
- |
| Cl. No.5.2(Visual Observation) |
- |
500 |
|
- |
| Cl. No.5.4(Breaking Strength of Fabric) |
- |
2200 |
|
Length Wise-1100
Width Wise-1100 |
| Cl. No.5.5("Ash Content
a) For UV Stabilized Sack") |
- |
1200 |
|
- |
| Cl. No.5.5("Ash Content
a) For UV Stabilized Sack") |
- |
1200 |
|
- |
| Cl. No.5.5("Ash Content
b) For Non- UV Stabilized Sack") |
- |
1200 |
|
- |
| Cl. No.5.6(Drop Impact testing of filled sack) |
- |
850 |
|
- |
| Cl. No.5.7(UV Resistance) |
- |
10180 |
|
- |
| Cl. No.6.1(Printing on Sacks) |
- |
0 |
|
- |
| Cl. No.6.4.(BIS Certification Marking) |
- |
0 |
|
- |
|
09 Aug, 2028 |
- Included w.e.f.05.08.2025
Exclusion
Cl. No.5.3 (Mass of Bale)
Cl. No.6.3. (Marking on the Bale) |
| 1834 |
Amit Test and Calibration Centre (8172006)
| 8172006
| IS 7098 : Part 1 (2025) |
Crosslinked Polyethylene Insulated Thermoplastic Sheathed Cables - Specification Part 1 For Working Voltages up to and Including 1 100 Volts (Second Revision) |
- |
80000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl-4(Conductors -Material) |
- |
500 |
|
Rs. 20,000/- for C1,Rs. 35,000 for C2 & Rs 80000 for C3. Additional charge Rs 500 for each core Additional charge of Rs 2500 for optional test , Additional charge of Rs 2500 for Armour test |
| Cl-5, Table-1 (i)(Tensile strength) |
- |
3000 |
|
- |
| Cl-5, Table-1 (ii) (a)(Elongation at break- Ageing in air oven) |
- |
5000 |
|
- |
| Cl-5, Table-1 (ii) (b)(Variation in tensile strength, from that without ageing) |
- |
1500 |
|
- |
| Cl-5, Table-1 (ii) (c)(Variation in elongation at break, from that without ageing) |
- |
1500 |
|
- |
| Cl-5, Table-1 (iii) (a)(Hot set- Treatment;) |
- |
2000 |
|
- |
| Cl-5, Table-1 (iii) (b)(Hot set- Elongation under load) |
- |
2000 |
|
- |
| Cl-5, Table-1 (iii) (c)(Hot set- Permanent elongation after cooling) |
- |
2000 |
|
- |
| Cl-5, Table-1 (iv)(Shrinkage) |
- |
1500 |
|
- |
| Cl-5, Table-1 (v)(Water absorption (gravimetric)) |
- |
7000 |
|
- |
| Cl-5, Table-1 (vi)(Volume resistivity) |
- |
5000 |
|
- |
| Cl-6.1 (a)(Fillers and inner sheath- Vulcanized or unvulcanized rubber) |
- |
500 |
|
- |
| Cl-6.1 (B)(Fillers and inner sheath- Thermoplastic materials) |
- |
500 |
|
- |
| Cl-7(Armouring) |
- |
500 |
|
- |
| Cl-8(Outer Sheath) |
- |
500 |
|
- |
| Cl-10.3(Tolerance on Thickness of Insulation) |
- |
1000 |
|
- |
| Cl-11(Core Identification) |
- |
500 |
|
- |
| Cl-12(Laying up of Cores) |
- |
500 |
|
- |
| Cl-13(Inner Sheath (Common Covering)) |
- |
500 |
|
- |
| Cl-14.1(Armouring- Application) |
- |
500 |
|
- |
| Cl-14.1.2(armour round wires/formed wires) |
- |
100 |
|
- |
| Cl-14.2(Type of Armour) |
- |
500 |
|
- |
| Cl-14.3(Dimensions) |
- |
1500 |
|
- |
| Cl-14.4(Joints) |
- |
500 |
|
- |
| Cl-14.5(Resistance) |
- |
2500 |
|
- |
| Cl-15.3(Thickness of Outer Sheath) |
- |
2000 |
|
- |
| Cl-16.1 (i) (a)(Test on conductor: Annealing test (for copper);) |
- |
1500 |
|
- |
| Cl-16.1 (i) (b)(Test on conductor: Tensile test (for aluminium);) |
- |
1500 |
|
- |
| Cl-16.1 (i) (c)(Test on conductor: Wrapping test (for aluminium);) |
- |
1500 |
|
- |
| Cl-16.1 (i) (d)(Test on conductor: Resistance test) |
- |
5000 |
|
- |
| Cl-14.6 (a)(Physical tests on round wires/formed wires- Tensile strength) |
- |
2500 |
|
- |
| Cl-14.6 (b)(Physical tests on round wires/formed wires- Elongation at break) |
- |
2500 |
|
- |
| Cl-14.6 (c)(Physical tests on round wires/formed wires- Torsion test for round wires) |
- |
3000 |
|
- |
| Cl-14.6 (d)(Physical tests on round wires/formed wires- Winding test for formed wires) |
- |
3000 |
|
- |
| Cl-14.6 (e)(Physical tests on round wires/formed wires- Uniformity of zinc coating) |
- |
2500 |
|
- |
| Cl-14.6 (f)(Physical tests on round wires/formed wires- Mass of zinc coating) |
- |
2500 |
|
- |
| Cl-14.6 (g)(Physical tests on round wires/formed wires- Resistivity.) |
- |
5000 |
|
- |
| Cl-10, 13, 15(Test for thickness of insulation and sheath) |
- |
5000 |
|
- |
| Cl-16.1 (v) (1)(PVC Sheath- Tensile strength and elongation at break;) |
- |
5000 |
|
- |
| Cl-16.1 (v) (2)(PVC Sheath- Ageing in air oven) |
- |
5000 |
|
- |
| Cl-16.1 (v) (3)(PVC Sheath- Loss of mass in air oven) |
- |
5000 |
|
- |
| Cl-16.1 (v) (5)(PVC Sheath- Hot deformation test) |
- |
3000 |
|
- |
| Cl-16.1 (v) (6)(PVC Sheath- Heat shock test) |
- |
2500 |
|
- |
| Cl-16.1 (v) (7)(PVC Sheath- Thermal stability) |
- |
3500 |
|
- |
| Cl-8.3-Table 1A(PE Sheath- Carbon black content) |
- |
3500 |
|
- |
| Cl-8.3-Table 1A(PE Sheath- Tensile strength and elongation at break before and after ageing) |
- |
7000 |
|
- |
| Cl-8.3-Table 1A(PE Sheath- Hot deformation) |
- |
3500 |
|
- |
| Cl-8.3-Table 1A(PE Sheath- Shrinkage test.) |
- |
2500 |
|
- |
| Cl- Table 1B(LSHF Sheath- Tensile strength and elongation at break before and after ageing) |
- |
7000 |
|
- |
| Cl- Table 1B(LSHF Sheath- Hot deformation) |
- |
3500 |
|
- |
| Cl- Table 1B(LSHF Sheath- Water absorption test) |
- |
7000 |
|
- |
| Cl- Table 1B(LSHF Sheath- Shrinkage test) |
- |
2500 |
|
- |
| Cl-17.2(High voltage test) |
- |
5000 |
|
- |
| Cl-17.3(Flammability test) |
- |
3000 |
|
- |
| Cl-17.4(Oxygen index test (FR, FR-LSH or LSHF Sheath)) |
- |
5000 |
|
- |
| Cl-17.5(Flame retardance test on single cable) |
- |
5000 |
|
- |
| Cl-17.6(Flame retardance test on bunched cables (FR, FR-LSH or LSHF Sheathed Cables)) |
- |
10000 |
|
- |
| Cl-17.7(Test for halogen acid evolution (FR-LSH or LSHF Outer Sheath)) |
- |
10000 |
|
- |
| Cl-17.8(Smoke density test (FR-LSH or LSHF Sheath)) |
- |
10000 |
|
- |
| Cl-17.9(Temperature index test; (FR, FR-LSH or LSHF Sheath)) |
- |
5000 |
|
- |
| Cl-17.10(Test for pH and conductivity of LSHF Sheath) |
- |
10000 |
|
- |
| Cl-17.11(Test for light transmission for LSHF Sheathed Cables) |
- |
40000 |
|
- |
| Cl-16.4 (i)(Cold bend test for outer sheath) |
- |
3500 |
|
- |
| Cl-16.4 (ii)(Cold impact test for outer sheath) |
- |
3500 |
|
- |
| Cl-16.4 (iii)(Cold elongation test for LSHF sheath) |
- |
15000 |
|
- |
|
16 Apr, 2026 |
- Included w.e.f 10.10.2025 |
| 1835 |
Central Institute of Petrochemicals Engineering & Technology (CIPET), Murthal
| 9121934
| IS 14611 (2024) |
Multilayered Cross Laminated Sheets/Tarpaulins/Covers/Agricultural Films â Specification (Second Revision) |
Type- XLn, LN,MN, HN, XHN |
41955 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl-6.1(Workmanship) |
- |
500 |
|
- |
| Cl-6.2, 6.3 & 6.8, Table-1 (i)(Mass per unit area, g/m²) |
- |
500 |
|
- |
| Cl-6.2, 6.3 & 6.8, Table-1 (ii)("Tensile strength1), Min,kg/cm²-
(a) Longitudinal direction") |
- |
1300 |
|
- |
| Cl-6.2, 6.3 & 6.8, Table-1 (ii)("Tensile strength1), Min,kg/cm²
(b) Transverse direction") |
- |
1300 |
|
- |
| Cl-6.2, 6.3 & 6.8, Table-1 (iii)("After ageing at 70 ºC ± 1 ºC for 168 h, Max, kg/cm2
a)Longitudinaldirection") |
- |
1300 |
|
- |
| Cl-6.2, 6.3 & 6.8, Table-1 (iii)("After ageing at 70 ºC ± 1 ºC for 168 h, Max, kg/cm2
b) Transverse direction") |
- |
1300 |
|
- |
| Cl-6.2, 6.3 & 6.8, Table-1 (iv)("Elongation at break, Min, percent
a)Longitudinaldirection") |
- |
0 |
|
INCLUDED IN TENSILE STRENGTH |
| Cl-6.2, 6.3 & 6.8, Table-1 (iv)("Elongation at break, Min, percent
b) Transverse direction") |
- |
0 |
|
INCLUDED IN TENSILE STRENGTH |
| Cl-6.2, 6.3 & 6.8, Table-1 (v)("Tear strength, Min, g:
a)Longitudinaldirection") |
- |
1300 |
|
- |
| Cl-6.2, 6.3 & 6.8, Table-1 (v)("Tear strength, Min, g:
b)Transverse direction") |
- |
1300 |
|
- |
| Cl-6.2, 6.3 & 6.8, Table-1 (vi)(Dart impact strength, Min, g) |
- |
850 |
|
- |
| Cl-6.2, 6.3 & 6.8, Table-1 (vii)(Average tensile strengthand elongation at breakafter exposing to UVradiation and weathering,Min, (kgf)) |
- |
12780 |
|
Testing Charges-2600
Conditioning Charges-10180 |
| Cl-6.4(Water Proofness Test) |
- |
1000 |
|
- |
| Cl-6.5(Strength of Joints/Seams) |
- |
1100 |
|
- |
| Cl-6.6(Flex Test) |
- |
7200 |
|
Testing Charges-3000
Conditioning Charges-4200 |
| Cl-6.7(Ease of In-Situ Repair) |
- |
500 |
|
- |
| Cl-7(Fixing of Eyelets (for tarpaulins only)) |
- |
500 |
|
- |
| Cl-9(Packing and Marking) |
- |
0 |
|
- |
| Cl-6.3(Accelerated Ageing Test) |
- |
4200 |
|
- |
| Cl-5(Construction of sheets/tarpaulins/covers/agricultural films) |
- |
0 |
|
- |
|
09 Aug, 2028 |
- Included w.e.f.05.08.2025 |
| 1836 |
Stellar Test House, Noida
| 8171606
| IS 7098 : Part 1 (2025) |
Crosslinked Polyethylene Insulated Thermoplastic Sheathed Cables - Specification Part 1 For Working Voltages up to and Including 1 100 Volts (Second Revision) |
- |
40000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl-4(Conductors -Material) |
- |
200 |
|
Complete testing charges=Rs.40000/- Rs.10000/- for Single core unarmoured cable; Rs.2000/- for each addl. Core; Rs.4000/- addl. For armoured cable; Rs.9000/- for addl. Tests for Cat-C1(FR); Rs.13000/- for addl. Tests for Cat-C2 (FR-LSH); Rs.20000/- for ad |
| Cl-5, Table-1 (i)(Tensile strength) |
- |
500 |
|
- |
| Cl-5, Table-1 (ii) (a)(Elongation at break- Ageing in air oven) |
- |
500 |
|
- |
| Cl-5, Table-1 (ii) (b)(Variation in tensile strength, from that without ageing) |
- |
300 |
|
- |
| Cl-5, Table-1 (ii) (c)(Variation in elongation at break, from that without ageing) |
- |
300 |
|
- |
| Cl-5, Table-1 (iii) (a)(Hot set- Treatment;) |
- |
1000 |
|
- |
| Cl-5, Table-1 (iii) (b)(Hot set- Elongation under load) |
- |
1000 |
|
- |
| Cl-5, Table-1 (iii) (c)(Hot set- Permanent elongation after cooling) |
- |
1000 |
|
- |
| Cl-5, Table-1 (iv)(Shrinkage) |
- |
500 |
|
- |
| Cl-5, Table-1 (v)(Water absorption (gravimetric)) |
- |
3000 |
|
- |
| Cl-5, Table-1 (vi)(Volume resistivity) |
- |
500 |
|
- |
| Cl-6.1 (a)(Fillers and inner sheath- Vulcanized or unvulcanized rubber) |
- |
200 |
|
- |
| Cl-6.1 (B)(Fillers and inner sheath- Thermoplastic materials) |
- |
100 |
|
- |
| Cl-7(Armouring) |
- |
1000 |
|
- |
| Cl-8(Outer Sheath) |
- |
200 |
|
- |
| Cl-10.3(Tolerance on Thickness of Insulation) |
- |
250 |
|
- |
| Cl-11(Core Identification) |
- |
100 |
|
- |
| Cl-12(Laying up of Cores) |
- |
100 |
|
- |
| Cl-13(Inner Sheath (Common Covering)) |
- |
100 |
|
- |
| Cl-14.1(Armouring- Application) |
- |
100 |
|
- |
| Cl-14.1.2(armour round wires/formed wires) |
- |
100 |
|
- |
| Cl-14.2(Type of Armour) |
- |
100 |
|
- |
| Cl-14.3(Dimensions) |
- |
100 |
|
- |
| Cl-14.4(Joints) |
- |
100 |
|
- |
| Cl-14.5(Resistance) |
- |
500 |
|
- |
| Cl-15.3(Thickness of Outer Sheath) |
- |
200 |
|
- |
| Cl-16.1 (i) (a)(Test on conductor: Annealing test (for copper);) |
- |
300 |
|
- |
| Cl-16.1 (i) (b)(Test on conductor: Tensile test (for aluminium);) |
- |
250 |
|
- |
| Cl-16.1 (i) (c)(Test on conductor: Wrapping test (for aluminium);) |
- |
250 |
|
- |
| Cl-16.1 (i) (d)(Test on conductor: Resistance test) |
- |
500 |
|
- |
| Cl-14.6 (a)(Physical tests on round wires/formed wires- Tensile strength) |
- |
200 |
|
- |
| Cl-14.6 (b)(Physical tests on round wires/formed wires- Elongation at break) |
- |
200 |
|
- |
| Cl-14.6 (c)(Physical tests on round wires/formed wires- Torsion test for round wires) |
- |
500 |
|
- |
| Cl-14.6 (d)(Physical tests on round wires/formed wires- Winding test for formed wires) |
- |
500 |
|
- |
| Cl-14.6 (e)(Physical tests on round wires/formed wires- Uniformity of zinc coating) |
- |
500 |
|
- |
| Cl-14.6 (f)(Physical tests on round wires/formed wires- Mass of zinc coating) |
- |
500 |
|
- |
| Cl-14.6 (g)(Physical tests on round wires/formed wires- Resistivity.) |
- |
500 |
|
- |
| Cl-10, 13, 15(Test for thickness of insulation and sheath) |
- |
250 |
|
- |
| Cl-16.1 (v) (1)(PVC Sheath- Tensile strength and elongation at break;) |
- |
250 |
|
- |
| Cl-16.1 (v) (2)(PVC Sheath- Ageing in air oven) |
- |
300 |
|
- |
| Cl-16.1 (v) (3)(PVC Sheath- Loss of mass in air oven) |
- |
300 |
|
- |
| Cl-16.1 (v) (6)(PVC Sheath- Heat shock test) |
- |
500 |
|
- |
| Cl-16.1 (v) (7)(PVC Sheath- Thermal stability) |
- |
500 |
|
- |
| Cl-8.3-Table 1A(PE Sheath- Carbon black content) |
- |
1000 |
|
- |
| Cl-8.3-Table 1A(PE Sheath- Tensile strength and elongation at break before and after ageing) |
- |
1000 |
|
- |
| Cl-8.3-Table 1A(PE Sheath- Hot deformation) |
- |
1000 |
|
- |
| Cl-8.3-Table 1A(PE Sheath- Shrinkage test.) |
- |
1000 |
|
- |
| Cl- Table 1B(LSHF Sheath- Tensile strength and elongation at break before and after ageing) |
- |
500 |
|
- |
| Cl- Table 1B(LSHF Sheath- Hot deformation) |
- |
500 |
|
- |
| Cl- Table 1B(LSHF Sheath- Shrinkage test) |
- |
500 |
|
- |
| Cl-17.2(High voltage test) |
- |
500 |
|
- |
| Cl-17.3(Flammability test) |
- |
500 |
|
- |
| Cl-17.4(Oxygen index test (FR, FR-LSH or LSHF Sheath)) |
- |
10000 |
|
- |
| Cl-17.5(Flame retardance test on single cable) |
- |
5000 |
|
- |
| Cl-17.6(Flame retardance test on bunched cables (FR, FR-LSH or LSHF Sheathed Cables)) |
- |
5000 |
|
- |
| Cl-17.7(Test for halogen acid evolution (FR-LSH or LSHF Outer Sheath)) |
- |
5000 |
|
- |
| Cl-17.8(Smoke density test (FR-LSH or LSHF Sheath)) |
- |
5000 |
|
- |
| Cl-17.9(Temperature index test; (FR, FR-LSH or LSHF Sheath)) |
- |
5000 |
|
- |
| Cl-17.10(Test for pH and conductivity of LSHF Sheath) |
- |
500 |
|
- |
| Cl-17.11(Test for light transmission for LSHF Sheathed Cables) |
- |
500 |
|
- |
| Cl-16.4 (i)(Cold bend test for outer sheath) |
- |
500 |
|
- |
| Cl-16.4 (ii)(Cold impact test for outer sheath) |
- |
500 |
|
- |
| Cl-16.4 (iii)(Cold elongation test for LSHF sheath) |
- |
500 |
|
- |
| Cl-16.1 (v) (5)(PVC Sheath- Hot deformation test) |
- |
500 |
|
- |
| Cl- Table 1B(LSHF Sheath- Water absorption test) |
- |
2000 |
|
- |
| Cl-4(Conductors -Material) |
- |
200 |
|
- |
| Cl-5, Table-1 (i)(Tensile strength) |
- |
500 |
|
- |
| Cl-5, Table-1 (ii) (a)(Elongation at break- Ageing in air oven) |
- |
500 |
|
- |
| Cl-5, Table-1 (ii) (b)(Variation in tensile strength, from that without ageing) |
- |
500 |
|
- |
| Cl-5, Table-1 (ii) (c)(Variation in elongation at break, from that without ageing) |
- |
500 |
|
- |
| Cl-5, Table-1 (iii) (a)(Hot set- Treatment;) |
- |
500 |
|
- |
| Cl-5, Table-1 (iii) (b)(Hot set- Elongation under load) |
- |
500 |
|
- |
| Cl-5, Table-1 (iii) (c)(Hot set- Permanent elongation after cooling) |
- |
500 |
|
- |
| Cl-5, Table-1 (iv)(Shrinkage) |
- |
300 |
|
- |
| Cl-5, Table-1 (v)(Water absorption (gravimetric)) |
- |
2000 |
|
- |
| Cl-5, Table-1 (vi)(Volume resistivity) |
- |
500 |
|
- |
| Cl-6.1 (a)(Fillers and inner sheath- Vulcanized or unvulcanized rubber) |
- |
200 |
|
- |
| Cl-6.1 (B)(Fillers and inner sheath- Thermoplastic materials) |
- |
200 |
|
- |
| Cl-7(Armouring) |
- |
500 |
|
- |
| Cl-8(Outer Sheath) |
- |
500 |
|
- |
| Cl-10.3(Tolerance on Thickness of Insulation) |
- |
200 |
|
- |
| Cl-11(Core Identification) |
- |
200 |
|
- |
| Cl-12(Laying up of Cores) |
- |
200 |
|
- |
| Cl-13(Inner Sheath (Common Covering)) |
- |
200 |
|
- |
| Cl-14.1(Armouring- Application) |
- |
200 |
|
- |
| Cl-14.1.2(armour round wires/formed wires) |
- |
200 |
|
- |
| Cl-14.2(Type of Armour) |
- |
200 |
|
- |
| Cl-14.3(Dimensions) |
- |
200 |
|
- |
| Cl-14.4(Joints) |
- |
200 |
|
- |
| Cl-14.5(Resistance) |
- |
500 |
|
- |
| Cl-15.3(Thickness of Outer Sheath) |
- |
500 |
|
- |
| Cl-16.1 (i) (a)(Test on conductor: Annealing test (for copper);) |
- |
500 |
|
- |
| Cl-16.1 (i) (b)(Test on conductor: Tensile test (for aluminium);) |
- |
500 |
|
- |
| Cl-16.1 (i) (c)(Test on conductor: Wrapping test (for aluminium);) |
- |
500 |
|
- |
| Cl-16.1 (i) (d)(Test on conductor: Resistance test) |
- |
500 |
|
- |
| Cl-14.6 (a)(Physical tests on round wires/formed wires- Tensile strength) |
- |
500 |
|
- |
| Cl-14.6 (b)(Physical tests on round wires/formed wires- Elongation at break) |
- |
500 |
|
- |
| Cl-14.6 (c)(Physical tests on round wires/formed wires- Torsion test for round wires) |
- |
500 |
|
- |
| Cl-14.6 (d)(Physical tests on round wires/formed wires- Winding test for formed wires) |
- |
500 |
|
- |
| Cl-14.6 (e)(Physical tests on round wires/formed wires- Uniformity of zinc coating) |
- |
500 |
|
- |
| Cl-14.6 (f)(Physical tests on round wires/formed wires- Mass of zinc coating) |
- |
500 |
|
- |
| Cl-14.6 (g)(Physical tests on round wires/formed wires- Resistivity.) |
- |
500 |
|
- |
| Cl-10, 13, 15(Test for thickness of insulation and sheath) |
- |
200 |
|
- |
| Cl-16.1 (v) (1)(PVC Sheath- Tensile strength and elongation at break;) |
- |
200 |
|
- |
| Cl-16.1 (v) (2)(PVC Sheath- Ageing in air oven) |
- |
500 |
|
- |
| Cl-16.1 (v) (3)(PVC Sheath- Loss of mass in air oven) |
- |
500 |
|
- |
| Cl-16.1 (v) (6)(PVC Sheath- Heat shock test) |
- |
500 |
|
- |
| Cl-16.1 (v) (7)(PVC Sheath- Thermal stability) |
- |
500 |
|
- |
| Cl-8.3-Table 1A(PE Sheath- Carbon black content) |
- |
1000 |
|
- |
| Cl-8.3-Table 1A(PE Sheath- Tensile strength and elongation at break before and after ageing) |
- |
1000 |
|
- |
| Cl-8.3-Table 1A(PE Sheath- Hot deformation) |
- |
1000 |
|
- |
| Cl-8.3-Table 1A(PE Sheath- Shrinkage test.) |
- |
1000 |
|
- |
| Cl- Table 1B(LSHF Sheath- Tensile strength and elongation at break before and after ageing) |
- |
1000 |
|
- |
| Cl- Table 1B(LSHF Sheath- Hot deformation) |
- |
1000 |
|
- |
| Cl- Table 1B(LSHF Sheath- Shrinkage test) |
- |
1000 |
|
- |
| Cl-17.2(High voltage test) |
- |
500 |
|
- |
| Cl-17.3(Flammability test) |
- |
500 |
|
- |
| Cl-17.4(Oxygen index test (FR, FR-LSH or LSHF Sheath)) |
- |
2500 |
|
- |
| Cl-17.5(Flame retardance test on single cable) |
- |
5000 |
|
- |
| Cl-17.6(Flame retardance test on bunched cables (FR, FR-LSH or LSHF Sheathed Cables)) |
- |
5000 |
|
- |
| Cl-17.7(Test for halogen acid evolution (FR-LSH or LSHF Outer Sheath)) |
- |
2500 |
|
- |
| Cl-17.8(Smoke density test (FR-LSH or LSHF Sheath)) |
- |
2500 |
|
- |
| Cl-17.9(Temperature index test; (FR, FR-LSH or LSHF Sheath)) |
- |
2500 |
|
- |
| Cl-17.10(Test for pH and conductivity of LSHF Sheath) |
- |
500 |
|
- |
| Cl-17.11(Test for light transmission for LSHF Sheathed Cables) |
- |
200 |
|
- |
| Cl-16.4 (i)(Cold bend test for outer sheath) |
- |
500 |
|
- |
| Cl-16.4 (ii)(Cold impact test for outer sheath) |
- |
500 |
|
- |
| Cl-16.4 (iii)(Cold elongation test for LSHF sheath) |
- |
500 |
|
- |
| Cl-16.1 (v) (5)(PVC Sheath- Hot deformation test) |
- |
500 |
|
- |
| Cl- Table 1B(LSHF Sheath- Water absorption test) |
- |
2000 |
|
- |
|
26 Sep, 2028 |
- Included w.e.f 12.09.2025 |
| 1837 |
URS PRODUCTS AND TESTING PVT. LTD. (A29), NOIDA
| 8168906
| IS 21 (2025) |
Wrought Aluminium and Aluminium Alloys for Manufacture of Utensils - Specification (Fifth Revision) |
- |
10000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl-4(General requirements) |
- |
300 |
|
- |
| Cl-5.1(Material) |
- |
300 |
|
- |
| Cl-5.2(Chemical composition and mechanical properties of grades in Cl 5.1) |
- |
300 |
|
- |
| Cl-5.3.1 a("Wrought Aluminium (with Minimum
99 Percent Al Content)- Iron+ Silicon") |
- |
300 |
|
- |
| Cl-5.3.1 b("Wrought Aluminium (with Minimum
99 Percent Al Content)- Chromium") |
- |
300 |
|
- |
| Cl-5.3.1 b("Wrought Aluminium (with Minimum
99 Percent Al Content)- Magnesium") |
- |
300 |
|
- |
| Cl-5.3.1 b("Wrought Aluminium (with Minimum
99 Percent Al Content)- Manganese") |
- |
300 |
|
- |
| Cl-5.3.1 b("Wrought Aluminium (with Minimum
99 Percent Al Content)- Nickel") |
- |
300 |
|
- |
| Cl-5.3.1 b("Wrought Aluminium (with Minimum
99 Percent Al Content)- Zinc") |
- |
300 |
|
- |
| Cl-5.3.1 b("Wrought Aluminium (with Minimum
99 Percent Al Content)- Titanium") |
- |
300 |
|
- |
| Cl-5.3.1 b("Wrought Aluminium (with Minimum
99 Percent Al Content)- Tin") |
- |
300 |
|
- |
| Cl-5.3.1 c("Wrought Aluminium (with Minimum
99 Percent Al Content)- Copper") |
- |
300 |
|
- |
| Cl-5.3.1 Note 1("Wrought Aluminium (with Minimum
99 Percent Al Content)- Aluminium") |
- |
300 |
|
- |
| Cl-5.3.1 d("Wrought Aluminium (with Minimum
99 Percent Al Content)- Others") |
- |
200 |
|
- |
| Cl-5.3.2, Table-1 (i)(Wrought Aluminium Alloys-Silicon) |
- |
300 |
|
- |
| Cl-5.3.2, Table-1 (ii)(Wrought Aluminium Alloys-Iron) |
- |
300 |
|
- |
| Cl-5.3.2, Table-1 (iii)(Wrought Aluminium Alloys-Copper) |
- |
300 |
|
- |
| Cl-5.3.2, Table-1 (iv)(Wrought Aluminium Alloys-Manganese) |
- |
300 |
|
- |
| Cl-5.3.2, Table-1 (v)(Wrought Aluminium Alloys-Magnesium) |
- |
300 |
|
- |
| Cl-5.3.2, Table-1 (vi)(Wrought Aluminium Alloys-Chromium) |
- |
300 |
|
- |
| Cl-5.3.2, Table-1 (vii)(Wrought Aluminium Alloys-Nickel) |
- |
300 |
|
- |
| Cl-5.3.2, Table-1 (viii)(Wrought Aluminium Alloys-Zinc) |
- |
300 |
|
- |
| Cl-5.3.2, Table-1 (ix)(Wrought Aluminium Alloys -Zirconium) |
- |
300 |
|
- |
| Cl-5.3.2, Table-1 (x)(Wrought Aluminium Alloys - Titanium) |
- |
300 |
|
- |
| Cl-5.3.2, Table-1 (Note 3)(Wrought Aluminium Alloys- Aluminium) |
- |
300 |
|
- |
| Cl-5.3.2, Table-1 (xi)(Wrought Aluminium Alloys- Others) |
- |
300 |
|
- |
| Cl 5.4(Lead) |
- |
300 |
|
- |
| Cl 5.4(Cadmium) |
- |
300 |
|
- |
| Cl 5.4(Arsenic) |
- |
300 |
|
- |
| Cl-7(Dimension) |
- |
300 |
|
- |
| Cl-8(EARING TEST (OPTIONAL TEST)) |
- |
300 |
|
- |
| Cl-4(General requirements) |
- |
200 |
|
- |
| Cl-5.1(Material) |
- |
300 |
|
- |
| Cl-5.2(Chemical composition and mechanical properties of grades in Cl 5.1) |
- |
300 |
|
- |
| Cl-5.3.1 a("Wrought Aluminium (with Minimum
99 Percent Al Content)- Iron+ Silicon") |
- |
300 |
|
- |
| Cl-5.3.1 b("Wrought Aluminium (with Minimum
99 Percent Al Content)- Chromium") |
- |
300 |
|
- |
| Cl-5.3.1 b("Wrought Aluminium (with Minimum
99 Percent Al Content)- Magnesium") |
- |
300 |
|
- |
| Cl-5.3.1 b("Wrought Aluminium (with Minimum
99 Percent Al Content)- Manganese") |
- |
300 |
|
- |
| Cl-5.3.1 b("Wrought Aluminium (with Minimum
99 Percent Al Content)- Nickel") |
- |
300 |
|
- |
| Cl-5.3.1 b("Wrought Aluminium (with Minimum
99 Percent Al Content)- Zinc") |
- |
300 |
|
- |
| Cl-5.3.1 b("Wrought Aluminium (with Minimum
99 Percent Al Content)- Titanium") |
- |
300 |
|
- |
| Cl-5.3.1 b("Wrought Aluminium (with Minimum
99 Percent Al Content)- Tin") |
- |
300 |
|
- |
| Cl-5.3.1 c("Wrought Aluminium (with Minimum
99 Percent Al Content)- Copper") |
- |
300 |
|
- |
| Cl-5.3.1 Note 1("Wrought Aluminium (with Minimum
99 Percent Al Content)- Aluminium") |
- |
300 |
|
- |
| Cl-5.3.1 d("Wrought Aluminium (with Minimum
99 Percent Al Content)- Others") |
- |
300 |
|
- |
| Cl-5.3.2, Table-1 (i)(Wrought Aluminium Alloys-Silicon) |
- |
300 |
|
- |
| Cl-5.3.2, Table-1 (ii)(Wrought Aluminium Alloys-Iron) |
- |
300 |
|
- |
| Cl-5.3.2, Table-1 (iii)(Wrought Aluminium Alloys-Copper) |
- |
300 |
|
- |
| Cl-5.3.2, Table-1 (iv)(Wrought Aluminium Alloys-Manganese) |
- |
300 |
|
- |
| Cl-5.3.2, Table-1 (v)(Wrought Aluminium Alloys-Magnesium) |
- |
300 |
|
- |
| Cl-5.3.2, Table-1 (vi)(Wrought Aluminium Alloys-Chromium) |
- |
300 |
|
- |
| Cl-5.3.2, Table-1 (vii)(Wrought Aluminium Alloys-Nickel) |
- |
300 |
|
- |
| Cl-5.3.2, Table-1 (viii)(Wrought Aluminium Alloys-Zinc) |
- |
300 |
|
- |
| Cl-5.3.2, Table-1 (ix)(Wrought Aluminium Alloys -Zirconium) |
- |
300 |
|
- |
| Cl-5.3.2, Table-1 (x)(Wrought Aluminium Alloys - Titanium) |
- |
300 |
|
- |
| Cl-5.3.2, Table-1 (Note 3)(Wrought Aluminium Alloys- Aluminium) |
- |
300 |
|
- |
| Cl-5.3.2, Table-1 (xi)(Wrought Aluminium Alloys- Others) |
- |
300 |
|
- |
| Cl 5.4(Lead) |
- |
300 |
|
- |
| Cl 5.4(Cadmium) |
- |
300 |
|
- |
| Cl 5.4(Arsenic) |
- |
300 |
|
- |
| Cl-7(Dimension) |
- |
300 |
|
- |
| Cl-8(EARING TEST (OPTIONAL TEST)) |
- |
300 |
|
- |
|
26 Sep, 2027 |
- Included w.e.f. 04.09.2025 |
| 1838 |
Dashmesh Test Lab Private Limited
| 8186926
| IS 555 (1979) |
Specification for electric table type fans and regulators (Third Revision) |
All |
11900 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 10.16(Creepage Distances and Clearances) |
- |
200 |
|
- |
| 10.14(Cord Grip Test) |
- |
500 |
|
- |
| 10.13, 7.4(Mechanical Endurance Test (for Regulators Only)) |
- |
500 |
|
- |
| 10.12(Moisture Resistance Test) |
- |
1000 |
|
- |
| 10.11(Protection against Electric Shock) |
- |
500 |
|
- |
| 10.1(Earthing Connection) |
- |
500 |
|
- |
| 10.9(Fan Speed and Input) |
- |
500 |
|
- |
| 10.8(Construction) |
- |
500 |
|
- |
| 10.7(Insulation-Resistance Test (Shall follow Moisture Resistance Test Cl.10.12)) |
- |
500 |
|
- |
| 10.6(High Voltage Test) |
- |
500 |
|
- |
| 10.5(Leakage Current) |
- |
500 |
|
- |
| 10.4(Temperature-Rise Test) |
- |
500 |
|
- |
| 10.3(Air Delivery Test) |
- |
1000 |
|
- |
| 9.0(Marking) |
- |
200 |
|
- |
| 7.11(Oscillating Mechanism) |
- |
500 |
|
- |
| 7.9(Interchangeability) |
- |
200 |
|
- |
| 7.8(Speed Regulators) |
- |
500 |
|
- |
| 6.0(Design and General Construction) |
- |
200 |
|
- |
| 5.0(Rated Frequency) |
- |
200 |
|
- |
| 4.0(Rated Voltages) |
- |
200 |
|
- |
| 3.0(Size, Speed and Types) |
- |
200 |
|
- |
| 7.1(Protection Against Electric Shock) |
- |
200 |
|
- |
| 7.2(Electrical Insulation Under Normal Operating Conditions) |
- |
200 |
|
- |
| 7.3(Temperature-rise) |
- |
500 |
|
- |
| 7.5(Creepage Distances and Clearances) |
- |
500 |
|
- |
| 7.6(Finish) |
- |
200 |
|
- |
| 7.7(Insulating Materials) |
- |
200 |
|
- |
| 7.10(Oscillating Mechanism) |
- |
500 |
|
- |
| 8.1, 8.2(Air delivery and service value) |
- |
500 |
|
- |
| 10.13, 7.4(Mechanical Endurance Test (for Regulators Only)) |
- |
500 |
|
- |
| 7.1(Protection Against Electric Shock) |
- |
500 |
|
- |
| 7.2(Electrical Insulation Under Normal Operating Conditions) |
- |
500 |
|
- |
| 7.3(Temperature-rise) |
- |
500 |
|
- |
| 7.5(Creepage Distances and Clearances) |
- |
500 |
|
- |
| 7.6(Finish) |
- |
500 |
|
- |
| 7.7(Insulating Materials) |
- |
500 |
|
- |
| 7.10(Oscillating Mechanism) |
- |
500 |
|
- |
| 8.1, 8.2(Air delivery and service value) |
- |
500 |
|
- |
| 10.13, 7.4(Mechanical Endurance Test (for Regulators Only)) |
- |
- |
|
- |
| 7.1(Protection Against Electric Shock) |
- |
- |
|
- |
| 7.2(Electrical Insulation Under Normal Operating Conditions) |
- |
- |
|
- |
| 7.3(Temperature-rise) |
- |
- |
|
- |
| 7.5(Creepage Distances and Clearances) |
- |
- |
|
- |
| 7.6(Finish) |
- |
- |
|
- |
| 7.7(Insulating Materials) |
- |
- |
|
- |
| 7.10(Oscillating Mechanism) |
- |
- |
|
- |
| 8.1, 8.2(Air delivery and service value) |
- |
- |
|
- |
|
22 Jul, 2028 |
- Included w.e.f.18.08.2025 |
| 1839 |
AA Electro Magnetic Laboratory Pvt Ltd, Gurugram
| 8165826
| IS 18112 (2022) |
Digital Television Receiver for Satellite Broadcast Transmission Specification |
- |
140000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 3.5(Safety specification) |
- |
60000 |
|
- |
| 3.6(Electromagnetic Compatibility (EMC) Requirements) |
- |
80000 |
|
- |
|
24 Sep, 2026 |
- Included w.e.f 10.09.2025
Exclusion: Restricted to only Cl.3.5(Safety specification)n & Cl.3.6 ((Electromagnetic Compatibility (EMC) Requirements) |
| 1840 |
EMC Testing and Compliance LLP, Gurugram
| 8141526
| IS 17634 (2022) |
Storage Units - Specification |
- |
30000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| CLAUSE 5(DIMENSIONS) |
- |
1000 |
|
- |
| CLAUSE 6(SURFACE PERFORMANCE) |
- |
4500 |
|
- |
| CLAUSE 6.2(Fabric and Leather (Synthetic and Natural) Performance) |
- |
7500 |
|
- |
| CLAUSE 7.1(SAFETY TESTS (General)) |
- |
1000 |
|
- |
| CLAUSE 7.2(Test for Non-Movable Parts) |
- |
1000 |
|
- |
| CLAUSE 7.2.1(Shelves) |
- |
1000 |
|
- |
| CLAUSE 7.2.1.2(Deflection of shelves) |
- |
1000 |
|
- |
| CLAUSE 7.2.2.1(Sustained load test for tops and bottoms) |
- |
1000 |
|
- |
| CLAUSE 7.2.2.2(Static load test for tops and bottoms) |
- |
1000 |
|
- |
| CLAUSE 7.2.3.1(Strength of clothes-rail supports) |
- |
1000 |
|
- |
| CLAUSE 7.2.3.2(Dislodgement of clothes rail) |
- |
1000 |
|
- |
| CLAUSE 7.2.4.2(Drop test) |
- |
1000 |
|
- |
| CLAUSE 7.2.4.3(Tests for units with castors or wheels) |
- |
1000 |
|
- |
| CLAUSE 7.3.1(Pivoted Doors) |
- |
1000 |
|
- |
| CLAUSE 7.3.1.2.1(Vertical load on pivoted door) |
- |
1000 |
|
- |
| CLAUSE 7.3.1.2.2(Horizontal load on pivoted door) |
- |
1000 |
|
- |
| CLAUSE 7.3.1.3(Slam-shut test of pivoted doors) |
- |
1000 |
|
- |
| CLAUSE 7.3.1.4(Durability of pivoted doors) |
- |
1000 |
|
- |
| CLAUSE 7.3.2(Sliding Doors and Horizontal Roll-fronts) |
- |
1000 |
|
- |
| CLAUSE 7.3.2.2(Slam shut/open test of sliding doors and horizontal roll-fronts) |
- |
1000 |
|
- |
| CLAUSE 7.3.2.3(Durability of sliding doors and horizontal roll-fronts) |
- |
9000 |
|
- |
| CLAUSE 7.3.3(Flaps) |
- |
30000 |
|
- |
| CLAUSE 7.3.3.1(Strength of bottom-hinged flaps) |
- |
1000 |
|
- |
| CLAUSE 7.3.3.2(Durability of flaps) |
- |
4000 |
|
- |
| CLAUSE 7.3.3.3(Drop test for top-hinged flaps) |
- |
1000 |
|
- |
| CLAUSE 7.3.4(Vertical Roll-Fronts) |
- |
1000 |
|
- |
| CLAUSE 7.3.4.1(Slam shut/open test of vertical roll-fronts) |
- |
1000 |
|
- |
| CLAUSE 7.3.4.2(Durability of vertical roll-fronts) |
- |
4000 |
|
- |
| CLAUSE 7.3.5(Extension Element) |
- |
1000 |
|
- |
| CLAUSE 7.3.5.2(Strength of extension elements) |
- |
1000 |
|
- |
| CLAUSE 7.3.5.3(Durability of extension elements) |
- |
13000 |
|
- |
| CLAUSE 7.3.5.4(Slam shut/open test of extension element) |
- |
1000 |
|
- |
| CLAUSE 7.3.5.5(Displacement of extension element bottoms) |
- |
1000 |
|
- |
| CLAUSE 7.3.5.6(Interlock test) |
- |
1000 |
|
- |
| CLAUSE 7.3.6(Locking and Latching Mechanism Tests) |
- |
1000 |
|
- |
| CLAUSE 7.3.6.2(Strength test for locking and latching mechanisms for extension elements) |
- |
1000 |
|
- |
| CLAUSE 7.3.6.3(Locking and latching mechanisms for doors, flaps and roll-fronts) |
- |
1000 |
|
- |
| CLAUSE 7.3.6.4(Durability test of locking and latching mechanisms) |
- |
4000 |
|
- |
| CLAUSE 7.3.7(Pull Force Test) |
- |
1000 |
|
- |
| CLAUSE 7.3.7(Pull Force Test) |
- |
1000 |
|
- |
| CLAUSE 7.3.8(Top Load Ease Cycle Test) |
- |
1000 |
|
- |
| CLAUSE 7.3.9(Durability Test for Units with Seating Surfaces – Cyclic Impact) |
- |
4000 |
|
- |
| CLAUSE 7.3.10("Drop Test – Dynamic – for Units with
Seat Surfaces") |
- |
1000 |
|
- |
| CLAUSE 7.4.1.3(Sustained load test (overload)) |
- |
1000 |
|
- |
| CLAUSE 7.4.1.4(Dislodgement test) |
- |
1000 |
|
- |
| CLAUSE 7.5(Stability Tests) |
- |
1000 |
|
- |
| CLAUSE 7.5.2.1("Units that can be adjusted to a Height of
1 000 mm or less") |
- |
1000 |
|
- |
| CLAUSE 7.5.2.2("Units that can be adjusted to a height of
more than 1 000 mm") |
- |
1000 |
|
- |
| CLAUSE 7.5.3(Opening Doors, Extension Elements and Flaps, All Storage Units Unloaded) |
- |
1000 |
|
- |
| CLAUSE 7.5.6(Vertical Force Stability Test for Storage Units) |
- |
1000 |
|
- |
| CLAUSE 7.5.7(Stability Test for Pedestals/Storage Units with Seat Surfaces) |
- |
1000 |
|
- |
| CLAUSE 7.5.9(Strength Test for Wall Attachments) |
- |
1000 |
|
- |
| Cl-6.1 (a)(Resistance to mechanical damage) |
- |
1000 |
|
- |
| Cl-6.1 (b)(Pencil hardness) |
- |
1000 |
|
- |
| Cl-6.1 (c)(Resistance to wet heat) |
- |
1500 |
|
- |
| Cl-6.1 (d)Cl-6.1 (d)(Resistance to dry heat) |
- |
1500 |
|
- |
| Cl-6.1 (e)(Resistance to marking by cold liquids) |
- |
1500 |
|
- |
| Cl-6.1 (g)(Adhesive performance) |
- |
1000 |
|
- |
| Cl-6.2 (a) 1(Breaking load) |
- |
1000 |
|
- |
| Cl-6.2 (a) 2(Elongation at break) |
- |
1000 |
|
- |
| Cl-6.2 (a) 3(Tear strength) |
- |
1000 |
|
- |
| Cl-6.2 (a) 4(Colour fastness to light) |
- |
1500 |
|
- |
| Cl-6.2 (a) 5(Colour fastness to rubbing) |
- |
1500 |
|
- |
| Cl-6.2 (a) 6(Colour fastness to perspiration) |
- |
1000 |
|
- |
| Cl-6.2 (a) 7(Colour fastness to water) |
- |
1000 |
|
- |
| Cl-6.2 (a) 8(Pilling resistance) |
- |
1000 |
|
- |
| Cl-6.2 (a) 9(Coating adhesion strength) |
- |
1000 |
|
- |
| Cl-6.2 (a) 10(Seam slippage) |
- |
1000 |
|
- |
| Cl-6.2 (a) 11(Resistance to damage by flexing) |
- |
1000 |
|
- |
| Cl-6.2 (a) 12(Abrasion resistance) |
- |
1000 |
|
- |
| Cl-6.2 (a) 13(Bursting strength) |
- |
1000 |
|
- |
| Cl-6.2 (a) 14(Resistance to cold) |
- |
1000 |
|
- |
| Cl-6.2 (b) 1(Tear strength) |
- |
1000 |
|
- |
| Cl-6.2 (b) 2(Flexing endurance) |
- |
1000 |
|
- |
| Cl-6.2 (b) 3(Finish adhesion) |
- |
1000 |
|
- |
| Cl-6.2 (b) 4(Colour fastness to artificial light) |
- |
1000 |
|
- |
| Cl-6.2 (b) 5(Colour fastness to rubbing) |
- |
1000 |
|
- |
| Cl-6.2 (b) 6(Colour fastness to water spotting) |
- |
1000 |
|
- |
| Cl-6.2 (b) 7(Water vapour permeability) |
- |
1000 |
|
- |
| Cl-6.2 (b) 8(Colour fastness to water) |
- |
1000 |
|
- |
| Cl-7.1(General) |
- |
0 |
|
Repeated |
| Cl-7.2.1(Shelves) |
- |
0 |
|
Repeated |
| Cl-7.2.2(Tops and Bottoms) |
- |
0 |
|
Repeated |
| Cl-7.2.3(Strength of Clothes Rails and their Supports) |
- |
0 |
|
Repeated |
| Cl-7.2.4(Strength of the Structure) |
- |
0 |
|
Repeated |
| Cl-7.3.1(Pivoted Doors) |
- |
0 |
|
Repeated |
| Cl-7.3.2(Sliding Doors and Horizontal Roll-fronts) |
- |
0 |
|
Repeated |
| Cl-7.3.3(Flaps) |
- |
0 |
|
Repeated |
| Cl-7.3.4(Vertical Roll-Fronts) |
- |
0 |
|
Repeated |
| Cl-7.3.5(Extension Elements) |
- |
0 |
|
Repeated |
| Cl-7.3.6(Locking and Latching Mechanism Test) |
- |
0 |
|
Repeated |
| Cl-7.3.7(Pull Force Test) |
- |
0 |
|
Repeated |
| Cl-7.3.8(Top Load Ease Cycle Test) |
- |
0 |
|
Repeated |
| Cl-7.3.9(Durability Test for Units with Seating Surfaces – Cyclic Impact) |
- |
0 |
|
Repeated |
| Cl-7.3.10(Drop Test – Dynamic – for Units with Seat Surfaces) |
- |
0 |
|
Repeated |
| Cl-7.4.1(Units Not Supported by the Floor) |
- |
0 |
|
Repeated |
| Cl-7.4.2(Units Supported by the Floor) |
- |
0 |
|
Repeated |
| Cl-7.5.1(General) |
- |
0 |
|
Repeated |
| Cl-7.5.2(Doors, Extension Elements and Flaps Closed, All Storage Units Unloaded) |
- |
0 |
|
Repeated |
| Cl-7.5.3(Opening Doors, Extension Elements and Flaps, All Storage Units Unloaded) |
- |
0 |
|
Repeated |
| Cl-7.5.4(Doors, Extension Elements and Flaps Opened and Unlocked) |
- |
0 |
|
Repeated |
| Cl-7.5.5(Doors, Extension Elements and Flaps Closed and Locked, All Storage Units Loaded) |
- |
0 |
|
Repeated |
| Cl-7.5.6(Vertical Force Stability Test for Storage Units) |
- |
0 |
|
Repeated |
| Cl-7.5.7(Stability Test for Pedestals/Storage Units with Seat Surfaces) |
- |
0 |
|
Repeated |
| Cl-7.5.8(Dynamic Stability Test for Units with Castors) |
- |
0 |
|
Repeated |
| Cl-7.5.9(Strength Test for Wall Attachments) |
- |
0 |
|
Repeated |
| Cl-9(Marking) |
- |
0 |
|
Repeated |
| CLAUSE 7.5.8("Dynamic Stability Test for Units with
Castors") |
- |
0 |
|
Repeated |
| Cl-6.1 (f)(Resistance to marking by cold oils and fats
Resistance to marking by cold oils and fats) |
- |
0 |
|
Repeated |
| CLAUSE 5(DIMENSIONS) |
- |
0 |
|
Repeated |
| CLAUSE 6(SURFACE PERFORMANCE) |
- |
0 |
|
Repeated |
| CLAUSE 6.2(Fabric and Leather (Synthetic and Natural) Performance) |
- |
0 |
|
Repeated |
| CLAUSE 7.1(SAFETY TESTS (General)) |
- |
0 |
|
Repeated |
| CLAUSE 7.2(Test for Non-Movable Parts) |
- |
0 |
|
Repeated |
| CLAUSE 7.2.1(Shelves) |
- |
0 |
|
Repeated |
| CLAUSE 7.2.1.2(Deflection of shelves) |
- |
0 |
|
Repeated |
| CLAUSE 7.2.2.1(Sustained load test for tops and bottoms) |
- |
0 |
|
Repeated |
| CLAUSE 7.2.2.2(Static load test for tops and bottoms) |
- |
0 |
|
Repeated |
| CLAUSE 7.2.3.1(Strength of clothes-rail supports) |
- |
0 |
|
Repeated |
| CLAUSE 7.2.3.2(Dislodgement of clothes rail) |
- |
0 |
|
Repeated |
| CLAUSE 7.2.4.2(Drop test) |
- |
0 |
|
Repeated |
| CLAUSE 7.2.4.3(Tests for units with castors or wheels) |
- |
0 |
|
Repeated |
| CLAUSE 7.3.1(Pivoted Doors) |
- |
0 |
|
Repeated |
| CLAUSE 7.3.1.2.1(Vertical load on pivoted door) |
- |
0 |
|
Repeated |
| CLAUSE 7.3.1.2.2(Horizontal load on pivoted door) |
- |
0 |
|
Repeated |
| CLAUSE 7.3.1.3(Slam-shut test of pivoted doors) |
- |
0 |
|
Repeated |
| CLAUSE 7.3.1.4(Durability of pivoted doors) |
- |
0 |
|
Repeated |
| CLAUSE 7.3.2(Sliding Doors and Horizontal Roll-fronts) |
- |
0 |
|
Repeated |
| CLAUSE 7.3.2.2(Slam shut/open test of sliding doors and horizontal roll-fronts) |
- |
0 |
|
Repeated |
| CLAUSE 7.3.2.3(Durability of sliding doors and horizontal roll-fronts) |
- |
0 |
|
Repeated |
| CLAUSE 7.3.3(Flaps) |
- |
0 |
|
Repeated |
| CLAUSE 7.3.3.1(Strength of bottom-hinged flaps) |
- |
0 |
|
Repeated |
| CLAUSE 7.3.3.2(Durability of flaps) |
- |
0 |
|
Repeated |
| CLAUSE 7.3.3.3(Drop test for top-hinged flaps) |
- |
0 |
|
Repeated |
| CLAUSE 7.3.4(Vertical Roll-Fronts) |
- |
0 |
|
Repeated |
| CLAUSE 7.3.4.1(Slam shut/open test of vertical roll-fronts) |
- |
0 |
|
Repeated |
| CLAUSE 7.3.4.2(Durability of vertical roll-fronts) |
- |
0 |
|
Repeated |
| CLAUSE 7.3.5(Extension Element) |
- |
0 |
|
Repeated |
| CLAUSE 7.3.5.2(Strength of extension elements) |
- |
0 |
|
Repeated |
| CLAUSE 7.3.5.3(Durability of extension elements) |
- |
0 |
|
Repeated |
| CLAUSE 7.3.5.4(Slam shut/open test of extension element) |
- |
0 |
|
Repeated |
| CLAUSE 7.3.5.5(Displacement of extension element bottoms) |
- |
0 |
|
Repeated |
| CLAUSE 7.3.5.6(Interlock test) |
- |
0 |
|
Repeated |
| CLAUSE 7.3.6(Locking and Latching Mechanism Tests) |
- |
0 |
|
Repeated |
| CLAUSE 7.3.6.2(Strength test for locking and latching mechanisms for extension elements) |
- |
0 |
|
Repeated |
| CLAUSE 7.3.6.3(Locking and latching mechanisms for doors, flaps and roll-fronts) |
- |
0 |
|
Repeated |
| CLAUSE 7.3.6.4(Durability test of locking and latching mechanisms) |
- |
0 |
|
Repeated |
| CLAUSE 7.3.7(Pull Force Test) |
- |
0 |
|
Repeated |
| CLAUSE 7.3.7(Pull Force Test) |
- |
0 |
|
Repeated |
| CLAUSE 7.3.8(Top Load Ease Cycle Test) |
- |
0 |
|
Repeated |
| CLAUSE 7.3.9(Durability Test for Units with Seating Surfaces – Cyclic Impact) |
- |
0 |
|
Repeated |
| CLAUSE 7.3.10("Drop Test – Dynamic – for Units with
Seat Surfaces") |
- |
0 |
|
Repeated |
| CLAUSE 7.4.1.3(Sustained load test (overload)) |
- |
0 |
|
Repeated |
| CLAUSE 7.4.1.4(Dislodgement test) |
- |
0 |
|
Repeated |
| CLAUSE 7.5(Stability Tests) |
- |
0 |
|
Repeated |
| CLAUSE 7.5.2.1("Units that can be adjusted to a Height of
1 000 mm or less") |
- |
0 |
|
Repeated |
| CLAUSE 7.5.2.2("Units that can be adjusted to a height of
more than 1 000 mm") |
- |
0 |
|
Repeated |
| CLAUSE 7.5.3(Opening Doors, Extension Elements and Flaps, All Storage Units Unloaded) |
- |
0 |
|
Repeated |
| CLAUSE 7.5.6(Vertical Force Stability Test for Storage Units) |
- |
0 |
|
Repeated |
| CLAUSE 7.5.7(Stability Test for Pedestals/Storage Units with Seat Surfaces) |
- |
0 |
|
Repeated |
| CLAUSE 7.5.9(Strength Test for Wall Attachments) |
- |
0 |
|
Repeated |
| Cl-6.1 (a)(Resistance to mechanical damage) |
- |
0 |
|
Repeated |
| Cl-6.1 (b)(Pencil hardness) |
- |
0 |
|
Repeated |
| Cl-6.1 (c)(Resistance to wet heat) |
- |
0 |
|
Repeated |
| Cl-6.1 (d)Cl-6.1 (d)(Resistance to dry heat) |
- |
0 |
|
Repeated |
| Cl-6.1 (e)(Resistance to marking by cold liquids) |
- |
0 |
|
Repeated |
| Cl-6.1 (g)(Adhesive performance) |
- |
0 |
|
Repeated |
| Cl-6.2 (a) 1(Breaking load) |
- |
0 |
|
Repeated |
| Cl-6.2 (a) 2(Elongation at break) |
- |
0 |
|
Repeated |
| Cl-6.2 (a) 3(Tear strength) |
- |
0 |
|
Repeated |
| Cl-6.2 (a) 4(Colour fastness to light) |
- |
0 |
|
Repeated |
| Cl-6.2 (a) 5(Colour fastness to rubbing) |
- |
0 |
|
Repeated |
| Cl-6.2 (a) 6(Colour fastness to perspiration) |
- |
0 |
|
Repeated |
| Cl-6.2 (a) 7(Colour fastness to water) |
- |
0 |
|
Repeated |
| Cl-6.2 (a) 8(Pilling resistance) |
- |
0 |
|
Repeated |
| Cl-6.2 (a) 9(Coating adhesion strength) |
- |
0 |
|
Repeated |
| Cl-6.2 (a) 10(Seam slippage) |
- |
0 |
|
Repeated |
| Cl-6.2 (a) 11(Resistance to damage by flexing) |
- |
0 |
|
Repeated |
| Cl-6.2 (a) 12(Abrasion resistance) |
- |
0 |
|
Repeated |
| Cl-6.2 (a) 13(Bursting strength) |
- |
0 |
|
Repeated |
| Cl-6.2 (a) 14(Resistance to cold) |
- |
0 |
|
Repeated |
| Cl-6.2 (b) 1(Tear strength) |
- |
0 |
|
Repeated |
| Cl-6.2 (b) 2(Flexing endurance) |
- |
0 |
|
Repeated |
| Cl-6.2 (b) 3(Finish adhesion) |
- |
0 |
|
Repeated |
| Cl-6.2 (b) 4(Colour fastness to artificial light) |
- |
0 |
|
Repeated |
| Cl-6.2 (b) 5(Colour fastness to rubbing) |
- |
0 |
|
Repeated |
| Cl-6.2 (b) 6(Colour fastness to water spotting) |
- |
0 |
|
Repeated |
| Cl-6.2 (b) 7(Water vapour permeability) |
- |
0 |
|
Repeated |
| Cl-6.2 (b) 8(Colour fastness to water) |
- |
0 |
|
Repeated |
| Cl-7.1(General) |
- |
0 |
|
Repeated |
| Cl-7.2.1(Shelves) |
- |
0 |
|
Repeated |
| Cl-7.2.2(Tops and Bottoms) |
- |
0 |
|
Repeated |
| Cl-7.2.3(Strength of Clothes Rails and their Supports) |
- |
0 |
|
Repeated |
| Cl-7.2.4(Strength of the Structure) |
- |
0 |
|
Repeated |
| Cl-7.3.1(Pivoted Doors) |
- |
0 |
|
Repeated |
| Cl-7.3.2(Sliding Doors and Horizontal Roll-fronts) |
- |
0 |
|
Repeated |
| Cl-7.3.3(Flaps) |
- |
0 |
|
Repeated |
| Cl-7.3.4(Vertical Roll-Fronts) |
- |
0 |
|
Repeated |
| Cl-7.3.5(Extension Elements) |
- |
0 |
|
Repeated |
| Cl-7.3.6(Locking and Latching Mechanism Test) |
- |
0 |
|
Repeated |
| Cl-7.3.7(Pull Force Test) |
- |
0 |
|
Repeated |
| Cl-7.3.8(Top Load Ease Cycle Test) |
- |
0 |
|
Repeated |
| Cl-7.3.9(Durability Test for Units with Seating Surfaces – Cyclic Impact) |
- |
0 |
|
Repeated |
| Cl-7.3.10(Drop Test – Dynamic – for Units with Seat Surfaces) |
- |
0 |
|
Repeated |
| Cl-7.4.1(Units Not Supported by the Floor) |
- |
0 |
|
Repeated |
| Cl-7.4.2(Units Supported by the Floor) |
- |
0 |
|
Repeated |
| Cl-7.5.1(General) |
- |
0 |
|
Repeated |
| Cl-7.5.2(Doors, Extension Elements and Flaps Closed, All Storage Units Unloaded) |
- |
0 |
|
Repeated |
| Cl-7.5.3(Opening Doors, Extension Elements and Flaps, All Storage Units Unloaded) |
- |
0 |
|
Repeated |
| Cl-7.5.4(Doors, Extension Elements and Flaps Opened and Unlocked) |
- |
0 |
|
Repeated |
| Cl-7.5.5(Doors, Extension Elements and Flaps Closed and Locked, All Storage Units Loaded) |
- |
0 |
|
RepeatedRepeated |
| Cl-7.5.6(Vertical Force Stability Test for Storage Units) |
- |
0 |
|
Repeated |
| Cl-7.5.7(Stability Test for Pedestals/Storage Units with Seat Surfaces) |
- |
0 |
|
Repeated |
| Cl-7.5.8(Dynamic Stability Test for Units with Castors) |
- |
0 |
|
Repeated |
| Cl-7.5.9(Strength Test for Wall Attachments) |
- |
0 |
|
Repeated |
| Cl-9(Marking) |
- |
0 |
|
Repeated |
| CLAUSE 7.5.8("Dynamic Stability Test for Units with
Castors") |
- |
0 |
|
Repeated |
| Cl-6.1 (f)(Resistance to marking by cold oils and fats
Resistance to marking by cold oils and fats) |
- |
0 |
|
Repeated |
|
19 Jul, 2027 |
- Included w.e.f 01.09.2025 |
| 1841 |
Central Institute of Petrochemicals Engineering & Technology (CIPET), Murthal
| 9121934
| IS 2508 (2024) |
Polyethylene Films and Sheets â Specification (Fourth Revision) |
Type- I, II, III, IV |
24625 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 5.1.4 Sl No. (i) of Table 1, Table 2, Table 3 & Table 4.(Density - IS 13360 : Part 3 : Sec 10 : 2021) |
- |
700 |
|
- |
| 5.1.6(Black Film- Carbon black - IS 2508:2024) |
- |
925 |
|
- |
| 5.1.6(Ash content - IS 2508: 2024) |
- |
1200 |
|
- |
| 5.1.6(carbon black dispersion - IS 2530: 1963) |
- |
700 |
|
- |
| 5.1.1(Appearance) |
- |
500 |
|
- |
| 5.1.2(Film Form) |
- |
0 |
|
Included in Visual appearance |
| 5.1.3(Odour) |
- |
0 |
|
Included in Visual appearance |
| 5.1.5(Melt Flow Index- IS 13360 : Part 4 : Sec 1 : subsec 1 or IS 13360 : Part 4 : Sec 1 : subsec 2) |
- |
1100 |
|
- |
| 5.2.1.1/ Table-1,2,3 &4(Nominal Thickness, Annex C,) |
- |
500 |
|
- |
| 5.2.1.2(Nominal Width) |
- |
500 |
|
- |
| 6, Type 1 (LDPE/LLDPE) /Table-1("Tensile strength at break-Machine direction, IS 13360 (Part 5/Sec 1) and
IS 13360 (Part 5/ Sec 3)") |
- |
1800 |
|
Testing Charges-1300
Specimen Charges- 500 |
| 6/Table-1("Tensile strength at break-Transverse direction, IS 13360 (Part 5/Sec 1) and
IS 13360 (Part 5/ Sec 3)") |
- |
1300 |
|
- |
| 6/Table-1("Elongation % at break, -Machine direction,IS 13360 (Part 5/Sec 1) and
IS 13360 (Part 5/ Sec 3)") |
- |
0 |
|
Included in Tensile Strength |
| 6/Table-1("Elongation % at break, -Transverse direction,IS 13360 (Part 5/Sec 1) and
IS 13360 (Part 5/ Sec 3)") |
- |
0 |
|
Included in Tensile Strength |
| 6/Table-1("Ageing test at (70 ± 1) ºC for 7 days-Machine Direction, IS 7016 (Part 8)
followed by IS 13360 (Part 5/Sec 1) and IS 13360 (Part 5/Sec 3)") |
- |
2100 |
|
- |
| 6/Table-1("Ageing test at (70 ± 1) ºC for 7 days- Transverse Direction, IS 7016 (Part 8)
followed by IS 13360 (Part 5/Sec 1) and IS 13360 (Part 5/Sec 3)") |
- |
2100 |
|
- |
| 6/Table-1(Dart impact strength,Method B of IS 13360 (Part 5/Sec 6)) |
- |
850 |
|
- |
| 6/Table-1(Tear resistance -Machine direction, IS 13360 (Part 5/Sec 23)) |
- |
1600 |
|
Testing Charges-1100
Specimen Charges- 500 |
| 6/Table-1(Tear resistance-Transverse direction, IS 13360 (Part 5/Sec 23)) |
- |
1100 |
|
- |
| " 7, Type 2 (HDPE/PE) /Table-2"("Tensile strength at break-Machine direction, IS 13360 (Part 5/Sec 1) and
IS 13360 (Part 5/ Sec 3)") |
- |
1800 |
|
Testing Charges-1300
Specimen Charges- 500 |
| " 7/Table-2"("Tensile strength at break-Transverse direction, IS 13360 (Part 5/Sec 1) and
IS 13360 (Part 5/ Sec 3)") |
- |
1300 |
|
- |
| " 7/Table-2"("Elongation % at break, -Machine direction,IS 13360 (Part 5/Sec 1) and
IS 13360 (Part 5/ Sec 3)") |
- |
0 |
|
Included in Tensile Strength |
| " 7/Table-2"("Elongation % at break, -Transverse direction,IS 13360 (Part 5/Sec 1) and
IS 13360 (Part 5/ Sec 3)") |
- |
0 |
|
Included in Tensile Strength |
| " 7/Table-2"("Ageing test at (70 ± 1) ºC for 7 days-Machine Direction, IS 7016 (Part 8)
followed by IS 13360 (Part 5/Sec 1) and IS 13360 (Part 5/Sec 3)") |
- |
2100 |
|
- |
| " 7/Table-2"("Ageing test at (70 ± 1) ºC for 7 days- Transverse Direction, IS 7016 (Part 8)
followed by IS 13360 (Part 5/Sec 1) and IS 13360 (Part 5/Sec 3)") |
- |
2100 |
|
- |
| " 7/Table-2"(Dart impact strength,Method B of IS 13360 (Part 5/Sec 6)) |
- |
850 |
|
- |
| 8, Type 3 (LDPE/LLDPE, PE) /Table-3("Average Tensile Break strength- Machine Direction, IS 13360 (Part 5/Sec 1) and
IS 13360 (Part 5/Sec 3)") |
- |
1800 |
|
Testing Charges-1300
Specimen Charges- 500 |
| 8/Table-3("Average Tensile Break strength- Transverse Direction, IS 13360 (Part 5/Sec 1) and
IS 13360 (Part 5/Sec 3)") |
- |
1300 |
|
- |
| 8/Table-3("Average Tensile Break Elongation %-Machine Direction, IS 13360 (Part 5/Sec 1) and
IS 13360 (Part 5/Sec 3)") |
- |
0 |
|
Included in Tensile Strength |
| 8/Table-3("Average Tensile Break Elongation %-Transverse Direction, IS 13360 (Part 5/Sec 1) and
IS 13360 (Part 5/Sec 3)") |
- |
0 |
|
Included in Tensile Strength |
| 8/Table-3(Average Tear resistance, IS 2508: 2024 Annex-D) |
- |
1600 |
|
Testing Charges-1100
Specimen Charges- 500 |
| 9, Type 4 (HDPE/PE) /Table-4("Average Yield strength- Machine Direction, IS 13360 (Part 5/Sec 1) and
IS 13360 (Part 5/Sec 3)") |
- |
1800 |
|
Testing Charges-1300
Specimen Charges- 500 |
| 9/Table-4("Average Yield strength- Transverse Direction, IS 13360 (Part 5/Sec 1) and
IS 13360 (Part 5/Sec 3)") |
- |
1300 |
|
- |
| 9/Table-4("Average Tensile Break strength- Machine Direction, IS 13360 (Part 5/Sec 1) and
IS 13360 (Part 5/Sec 3)") |
- |
1800 |
|
Testing Charges-1300
Specimen Charges- 500 |
| 9/Table-4("Average Tensile Break strength- Transverse Direction, IS 13360 (Part 5/Sec 1) and
IS 13360 (Part 5/Sec 3)") |
- |
1300 |
|
- |
| 9/Table-4("Average Tensile yield Elongation %-Machine Direction, IS 13360 (Part 5/Sec 1) and
IS 13360 (Part 5/Sec 3)") |
- |
0 |
|
Included in Tensile Strength |
| 9/Table-4("Average Tensile yield Elongation %-Transverse Direction, IS 13360 (Part 5/Sec 1) and
IS 13360 (Part 5/Sec 3)") |
- |
0 |
|
Included in Tensile Strength |
| 9/Table-4(Average Tensile Break Elongation %-Machine Direction, IS 13360 (Part 5/Sec 1) and IS 13360 (Part 5/Sec 3)) |
- |
0 |
|
Included in Tensile Strength |
| 9/Table-4(Average Tensile Break Elongation -Transverse Direction, IS 13360 (Part 5/Sec 1) and S 13360 (Part 5/Sec 3)) |
- |
0 |
|
Included in Tensile Strength |
| 9/Table-4(Average Tear resistance, IS 2508: 2024 Annex-D) |
- |
1600 |
|
Testing Charges-1100
Specimen Charges- 500 |
| 8/Table-3(Average Puncture resistance, IS 2508: 2024 Annex-E) |
- |
1100 |
|
- |
|
09 Aug, 2028 |
- Included w.e.f.05.08.2025 |
| 1842 |
EKO PRO ENGINEERS PRIVATE LIMITED (32/41), GHAZIABAD
| 9179706
| IS 6664 (1992) |
Rubber microcellular sheets for soles and heels - Specification (First Revision) |
ALL |
8500 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4.2(Flexing resistance ) |
- |
8500 |
|
- |
| 4.2(Water absorption) |
- |
8500 |
|
- |
| 4.2(Heat Shrinkage ) |
- |
8500 |
|
- |
| 4.2(Shrinkage at room temp) |
- |
8500 |
|
- |
| 4.2(Split tear strength) |
- |
8500 |
|
- |
| 4.2(Compression set) |
- |
8500 |
|
- |
| 4.2(Hardness (Shore A)) |
- |
8500 |
|
- |
| 4.2(Density ) |
- |
8500 |
|
- |
| 4.2(Size & Thickness ) |
- |
8500 |
|
- |
| 4, Cl.4.1,4.1.1,4.1.2(Requirements) |
- |
8500 |
|
- |
| Cl.4 Cl.4.1.3 And 8.3,Table1, i)(Relative density) |
- |
8500 |
|
- |
| Cl.4.1.3 And 8.3,Table1, iii)(Hardness, Shore A durometer min) |
- |
8500 |
|
- |
| Cl.4 Cl.4.1.3 And 8.3,Table1, iii)(Change in Hardness after ageing at 100±1°C for 24hr) |
- |
8500 |
|
- |
| Cl.4 Cl.4.1.3 And 8.3,Table1, iv)(Compression set at constant stress percent, Max) |
- |
8500 |
|
- |
| Cl.4 Cl.4.1.3 And 8.3,Table1, v)(Split tear strength, kg,Min) |
- |
8500 |
|
- |
| Cl.4 Cl.4.1.3 And 8.3,Table1, vi)(Room Temperature shrinkage at 27±2°C for 2weeks, percent, Max) |
- |
8500 |
|
- |
| Cl.4 Cl.4.1.3 And 8.3,Table 1, vi)(Heat shrinkage test at 100±1°C for 1 hour max) |
- |
8500 |
|
- |
| Cl.4 Cl.4.1.3 And 8.3,Table1, viii)(Water absorption , percent by mass, Max) |
- |
8500 |
|
- |
| Cl.4 Cl.4.1.3 And 8.3,Table 1, viii)(Flexing resistance: Maximum cut growth at 50 000 cycles) |
- |
8500 |
|
- |
| 5, 5.1(Marking) |
- |
8500 |
|
- |
| 6, 6.1(Packing) |
- |
8500 |
|
- |
| "Cl.4 ,Cl.4.1,4.1.1,4.1.2(Requirements
") |
- |
8500 |
|
- |
| Cl.4.1.3 And 8.3,Table1(i) Relative density) |
- |
8500 |
|
- |
| Cl.4.1.3 And 8.3,Table1(ii) Hardness, Shore A durometer min) |
- |
8500 |
|
- |
| Cl.4.1.3 And 8.3,Table1(iii) Change in Hardness after ageing at 100±1°C for 24hr) |
- |
8500 |
|
- |
| Cl.4.1.3 And 8.3,Table1(iv) Compression set at constant stress percent, Max) |
- |
8500 |
|
- |
| Cl.4.1.3 And 8.3,Table1(vi) Room Temperature shrinkage at 27±2°C for 2weeks, percent, Max) |
- |
8500 |
|
- |
| Cl.4.1.3 And 8.3,Table 1 vi(Heat shrinkage test at 100±1°C for 1 hour max) |
- |
8500 |
|
- |
| Cl.4.1.3 And 8.3,Table1(viii)Water absorption , percent by mass, Max) |
- |
8500 |
|
- |
| Cl.4.1.3 And 8.3,Table1(ix)Flexing resistance) |
- |
8500 |
|
- |
| 5, 5.1(Marking) |
- |
8500 |
|
- |
| 6, 6.1(Packing) |
- |
8500 |
|
- |
| Cl.4.1.3 and 8.3,Table 1 ii(Thickness) |
- |
8500 |
|
- |
| Cl.4.1.3 and 8.3,Table 1 vii(Abrasion resistance at applied force of 5 N) |
- |
8500 |
|
- |
|
26 Aug, 2027 |
- Included w.e.f 08.12.2025 |
| 1843 |
Rajkot Metlab Services LLP, Rajkot
| 7183706
| IS 278 (2009) |
Galvanized steel barbed wire for fencing - Specification (Fourth Revision) |
- |
5200 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4(Type A/Type B) |
- |
100 |
|
- |
| 5 Table-1(Sizes Diameter of Line wire) |
- |
100 |
|
- |
| 5 Table-1(Sizes Diamater of Point wire) |
- |
100 |
|
- |
| 5 Table-1(Sizes Mass of Completed barbed wire) |
- |
100 |
|
- |
| 5 Table-1(Sizes Distance between two barbs) |
- |
100 |
|
- |
| 5 Table-1(Sizes No. of Lays between the two consequtive barbs) |
- |
100 |
|
- |
| 7.1(Manufacture) |
- |
100 |
|
- |
| 7.2(Manufacture) |
- |
100 |
|
- |
| 7.2(Manufacture) |
- |
100 |
|
- |
| 7.3(Manufacture) |
- |
100 |
|
- |
| 8(CHROMATING) |
- |
1500 |
|
- |
| 9.1(Freedom from defects) |
- |
1000 |
|
- |
| 9.2(Freedom from defects) |
- |
1000 |
|
- |
| 9.2(Freedom from defects) |
- |
1000 |
|
- |
| 9.2(Freedom from defects) |
- |
1000 |
|
- |
| 12.1(Tensile Strength) |
- |
2000 |
|
- |
| 12.1(Breaking load) |
- |
2000 |
|
- |
| 12.2.1(Mass of zinc coating (line wire)) |
- |
2000 |
|
- |
| 12.2.2(Mass of zinc coating (point wire)) |
- |
2000 |
|
- |
| 12.2(Uniformity of zinc coating) |
- |
2000 |
|
- |
| 12.3(Ductility) |
- |
2000 |
|
- |
| Cl. 6 . Table 1 of IS 7887 (Grade : 1,2,3,4,4M,6,6M,7,7M,8,8M,9,10,10M)(Silicon- IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
2000 |
|
- |
| Cl. 6 . Table 1 of IS 7887 (Grade : 1,2,3,4,4M,6,6M,7,7M,8,8M,9,10,10M)(Phosphorus- IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
2000 |
|
- |
| Cl. 6 . Table 1 of IS 7887 (Grade : 1,2,3,4,4M,6,6M,7,7M,8,8M,9,10,10M)(Sulphur- IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
2000 |
|
- |
| Cl. 6 . Table 1 of IS 7887 (Grade : 1,2,3,4,4M,6,6M,7,7M,8,8M,9,10,10M)(Manganese- IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
2000 |
|
- |
| Cl. 6 . Table 1 of IS 7887 (Grade : 1,2,3,4,4M,6,6M,7,7M,8,8M,9,10,10M)(Carbon- IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
2000 |
|
- |
| Cl. 7.2(Cut Angle) |
- |
500 |
|
- |
| Cl. 7.2(Length of Barbs) |
- |
500 |
|
- |
| Cl. 7.2(Finishing of Barbs) |
- |
500 |
|
- |
| Cl. 7.1(General) |
- |
500 |
|
- |
| 11(Sampling) |
- |
500 |
|
- |
| 13(Marking) |
- |
100 |
|
- |
| CL 05(Average dia of line wire (08)) |
- |
100 |
|
- |
| CL 05(Average dia of point wire (08)) |
- |
100 |
|
- |
| CL 05(Average Distance Between Two Barbs (08)) |
- |
100 |
|
- |
|
12 Jan, 2028 |
- Included w.e.f.01.09.2025 |
| 1844 |
Central Institute of Petrochemicals Engineering & Technology (CIPET), Murthal
| 9121934
| IS 12786 (2024) |
Irrigation equipment - Polyethylene pipes for irrigation laterals - Specification (first revision) |
Up to 32 mm Diameter |
17725 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl-4.1(Material) |
- |
1050 |
|
- |
| Cl-4.2(Carbon content of finished PE lateral pipe) |
- |
925 |
|
- |
| Cl-5.1(Dimensions of pipes and wall thicknesses) |
- |
500 |
|
- |
| Cl-6.0(Visual Appearance) |
- |
500 |
|
- |
| Cl-7.1(Hydraulic Characteristics- Internal pressure creep rupture test) |
- |
3000 |
|
- |
| Cl-7.1(Hydraulic Characteristics- quality acceptance test) |
- |
1000 |
|
- |
| Cl-7.2(Reversion Test) |
- |
1200 |
|
Testing charges -700
Specimen Charges-500 |
| Cl-7.3(Tensile Test) |
- |
1800 |
|
Testing charges -1300
Specimen Charges-500 |
| Cl-7.3.1(Test Piece) |
- |
0 |
|
included in tensile charges |
| Cl-7.3.2(Procedure) |
- |
0 |
|
included in tensile charges |
| Cl-7.4(Susceptibility to Environmental Stress Cracking) |
- |
1200 |
|
- |
| Cl-8.0(Supply of pipes) |
- |
0 |
|
- |
| Cl-9.0(Coiling) |
- |
0 |
|
- |
| Cl-10.0(Sampling and criteria for conformity) |
- |
0 |
|
- |
| Cl-11(Marking) |
- |
0 |
|
included in Visual |
| 3(Class of Pipe) |
- |
0 |
|
- |
| 5.1 & Table 1(Dimensions of Pipes - Outside diameters) |
- |
500 |
|
- |
| 5.1 & Table 1(Dimensions of Pipes - Wall thickness) |
- |
0 |
|
- |
| 6(Visual Appearance) |
- |
500 |
|
- |
| 7.1 & Table 2(Hydraulic Characteristics) |
- |
1000 |
|
- |
| 7.1 & Table 2(Hydraulic Characteristics) |
- |
3000 |
|
- |
| 7.2(Reversion Test) |
- |
1200 |
|
Testing charges -700
Specimen Charges-500 |
| 7.3(Tensile Strength) |
- |
1800 |
|
Testing charges -1300
Specimen Charges-500 |
| 7.3(Elongation at Break) |
- |
1800 |
|
Testing charges -1300
Specimen Charges-500 |
| 7.4(SusceptibiIity to Environmental Stress Cracking) |
- |
1200 |
|
- |
| 4.2(a)(Carbon Black Content-IS 2530) |
- |
925 |
|
- |
| 4.2(b)(Carbon Black Dispersion-IS 2530) |
- |
700 |
|
- |
|
09 Aug, 2028 |
- Included w.e.f.05.08.2025 |
| 1845 |
SHRI KRISHNA TEST HOUSE PVT LTD (142)
| 8185606
| IS 21 (2025) |
Wrought Aluminium and Aluminium Alloys for Manufacture of Utensils - Specification (Fifth Revision) |
ALL |
7500 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl-4(General requirements) |
- |
7500 |
|
- |
| Cl-5.1(Material) |
- |
7500 |
|
- |
| Cl-5.2(Chemical composition and mechanical properties of grades in Cl 5.1) |
- |
7500 |
|
- |
| Cl-5.3.1 a("Wrought Aluminium (with Minimum
99 Percent Al Content)- Iron+ Silicon") |
- |
7500 |
|
- |
| Cl-5.3.1 b("Wrought Aluminium (with Minimum
99 Percent Al Content)- Chromium") |
- |
7500 |
|
- |
| Cl-5.3.1 b("Wrought Aluminium (with Minimum
99 Percent Al Content)- Magnesium") |
- |
7500 |
|
- |
| Cl-5.3.1 b("Wrought Aluminium (with Minimum
99 Percent Al Content)- Manganese") |
- |
7500 |
|
- |
| Cl-5.3.1 b("Wrought Aluminium (with Minimum
99 Percent Al Content)- Nickel") |
- |
7500 |
|
- |
| Cl-5.3.1 b("Wrought Aluminium (with Minimum
99 Percent Al Content)- Zinc") |
- |
7500 |
|
- |
| Cl-5.3.1 b("Wrought Aluminium (with Minimum
99 Percent Al Content)- Titanium") |
- |
7500 |
|
- |
| Cl-5.3.1 b("Wrought Aluminium (with Minimum
99 Percent Al Content)- Tin") |
- |
7500 |
|
- |
| Cl-5.3.1 c("Wrought Aluminium (with Minimum
99 Percent Al Content)- Copper") |
- |
7500 |
|
- |
| Cl-5.3.1 Note 1("Wrought Aluminium (with Minimum
99 Percent Al Content)- Aluminium") |
- |
7500 |
|
- |
| Cl-5.3.1 d("Wrought Aluminium (with Minimum
99 Percent Al Content)- Others") |
- |
7500 |
|
- |
| Cl-5.3.2, Table-1 (i)(Wrought Aluminium Alloys-Silicon) |
- |
7500 |
|
- |
| Cl-5.3.2, Table-1 (ii)(Wrought Aluminium Alloys-Iron) |
- |
7500 |
|
- |
| Cl-5.3.2, Table-1 (iii)(Wrought Aluminium Alloys-Copper) |
- |
7500 |
|
- |
| Cl-5.3.2, Table-1 (iv)(Wrought Aluminium Alloys-Manganese) |
- |
7500 |
|
- |
| Cl-5.3.2, Table-1 (v)(Wrought Aluminium Alloys-Magnesium) |
- |
7500 |
|
- |
| Cl-5.3.2, Table-1 (vi)(Wrought Aluminium Alloys-Chromium) |
- |
7500 |
|
- |
| Cl-5.3.2, Table-1 (vii)(Wrought Aluminium Alloys-Nickel) |
- |
7500 |
|
- |
| Cl-5.3.2, Table-1 (viii)(Wrought Aluminium Alloys-Zinc) |
- |
7500 |
|
- |
| Cl-5.3.2, Table-1 (ix)(Wrought Aluminium Alloys -Zirconium) |
- |
7500 |
|
- |
| Cl-5.3.2, Table-1 (x)(Wrought Aluminium Alloys - Titanium) |
- |
7500 |
|
- |
| Cl-5.3.2, Table-1 (Note 3)(Wrought Aluminium Alloys- Aluminium) |
- |
7500 |
|
- |
| Cl-5.3.2, Table-1 (xi)(Wrought Aluminium Alloys- Others) |
- |
7500 |
|
- |
| Cl 5.4(Lead) |
- |
7500 |
|
- |
| Cl 5.4(Cadmium) |
- |
7500 |
|
- |
| Cl 5.4(Arsenic) |
- |
7500 |
|
- |
| Cl-7(Dimension) |
- |
7500 |
|
- |
| Cl-8(EARING TEST (OPTIONAL TEST)) |
- |
7500 |
|
- |
|
13 May, 2028 |
- Included w.e.f 18.08.2025 |
| 1846 |
SHRI KRISHNA TEST HOUSE PVT LTD (142)
| 8185606
| IS 18380 (2023) |
DOMESTIC ETHANOL COOKSTOVE WITH FIXED AND REMOVABLE CANISTER TYPE SPECIFICATION |
ALL |
40000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl-4(Fuel Capacity) |
- |
40000 |
|
- |
| Cl-4.1(Fixed Canister Type) |
- |
40000 |
|
- |
| Cl-4.2(Removable Canister Type) |
- |
40000 |
|
- |
| Cl-6.1(Materials) |
- |
40000 |
|
- |
| Cl-6.2(Fuel Canister) |
- |
40000 |
|
- |
| Cl-6.3(Plastic components) |
- |
40000 |
|
- |
| Cl-6.4(Cookstoves body) |
- |
40000 |
|
- |
| Cl-6.5(Holding part/handle of the lever) |
- |
40000 |
|
- |
| Cl-6.6(Fuel Tank) |
- |
40000 |
|
- |
| Cl-7(Shape and Dimensions) |
- |
40000 |
|
- |
| Cl-8(Construction) |
- |
40000 |
|
- |
| Cl-10(Workmanship and Finish) |
- |
40000 |
|
- |
| Cl-11(Stove Lever) |
- |
40000 |
|
- |
| Cl-12(Pan Supports) |
- |
40000 |
|
- |
| Cl-13(Strength and Rigidity of body of the Cookstove) |
- |
40000 |
|
- |
| Cl-15.1(Fixed/Removable Canister Type) |
- |
40000 |
|
- |
| Cl-16(Thermal Efficiency) |
- |
40000 |
|
- |
| Cl-17(Surface Temperature) |
- |
40000 |
|
- |
| Cl-18(Combustion Efficiency) |
- |
40000 |
|
- |
| Cl-19(Resistance to Draught) |
- |
40000 |
|
- |
| Cl-20(Fuel Creep) |
- |
40000 |
|
- |
| Cl-22(Instructions) |
- |
40000 |
|
- |
| Cl-4(Fuel Capacity) |
- |
40000 |
|
- |
| Cl-4.1(Fixed Canister Type) |
- |
40000 |
|
- |
| Cl-4.2(Removable Canister Type) |
- |
40000 |
|
- |
| Cl-6.1(Materials) |
- |
40000 |
|
- |
| Cl-6.2(Fuel Canister) |
- |
40000 |
|
- |
| Cl-6.3(Plastic components) |
- |
40000 |
|
- |
| Cl-6.4(Cookstoves body) |
- |
40000 |
|
- |
| Cl-6.5(Holding part/handle of the lever) |
- |
40000 |
|
- |
| Cl-6.6(Fuel Tank) |
- |
40000 |
|
- |
| Cl-7(Shape and Dimensions) |
- |
40000 |
|
- |
| Cl-8(Construction) |
- |
40000 |
|
- |
| Cl-10(Workmanship and Finish) |
- |
40000 |
|
- |
| Cl-11(Stove Lever) |
- |
40000 |
|
- |
| Cl-12(Pan Supports) |
- |
40000 |
|
- |
| Cl-13(Strength and Rigidity of body of the Cookstove) |
- |
40000 |
|
- |
| Cl-15.1(Fixed/Removable Canister Type) |
- |
40000 |
|
- |
| Cl-16(Thermal Efficiency) |
- |
40000 |
|
- |
| Cl-17(Surface Temperature) |
- |
40000 |
|
- |
| Cl-18(Combustion Efficiency) |
- |
40000 |
|
- |
| Cl-19(Resistance to Draught) |
- |
40000 |
|
- |
| Cl-20(Fuel Creep) |
- |
40000 |
|
- |
| Cl-22(Instructions) |
- |
40000 |
|
- |
|
13 May, 2028 |
- Included w.e.f.26.08.2025 |
| 1847 |
SHRI BAJRANG TESTING LABS, GREATER NOIDA
| 8183006
| IS 15622 (2017) |
Pressed Ceramic Tiles - Specification (First Revision) |
ALL |
22500 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 5& 5.1, Table 1(Coordinating size- IS 13630(pt-1)) |
- |
200 |
|
- |
| 5& 5.1, Table 1(Work size- IS 13630(pt-1)) |
- |
200 |
|
- |
| 5& 5.1, Table 1(Thickness- IS 13630(pt-1)) |
- |
200 |
|
- |
| 5& 5.1, Table 2(Nominal size -IS 13630(pt-1)) |
- |
200 |
|
- |
| 5& 5.1, Table 2(Work size-IS 13630(pt-1)) |
- |
200 |
|
- |
| 5& 5.1, Table 2(Thickness- IS 13630(pt-1)) |
- |
200 |
|
- |
| 5& 5.1, Table 3(Coordinating size- IS 13630(pt-1)) |
- |
200 |
|
- |
| 5& 5.1, Table 3(Work size-IS 13630(pt-1)) |
- |
200 |
|
- |
| 5& 5.1, Table 3(Thickness- IS 13630(pt-1)) |
- |
200 |
|
- |
| 5& 5.1, Table 4(Nominal size-IS 13630(pt-1)) |
- |
200 |
|
- |
| 5& 5.1, Table 4(Work size-IS 13630(pt-1)) |
- |
200 |
|
- |
| 5& 5.1, Table 4(Thickness- IS 13630(pt-1)) |
- |
200 |
|
- |
| 6 table 5, i a (Length-IS 13630(pt-1)) |
- |
200 |
|
- |
| 6 table 5,i a (width-IS 13630(pt-1)) |
- |
200 |
|
- |
| 6 table 5, i b (Thickness- IS 13630(pt-1)) |
- |
200 |
|
- |
| 6 table 5, i c(Straigthness of side-IS 13630(pt-1)) |
- |
1000 |
|
- |
| 6 table 5, i d(Rectangularity-IS 13630(pt-1)) |
- |
1000 |
|
- |
| 6 table 5, i e(Surface flatness-IS 13630(pt-1)) |
- |
500 |
|
- |
| 6 table 5, i f(Surface quality-IS 13630(pt-1)) |
- |
500 |
|
- |
| 6 table 5, ii a(Water Absorption-IS 13630(pt-2)) |
- |
1000 |
|
- |
| 6 table 5, ii b(Module of rupture -IS 13630(pt-6)) |
- |
2500 |
|
- |
| 6 table 5, ii c(Bending Strength-IS 13630(pt-6)) |
- |
1000 |
|
- |
| 6 table 5, ii d(Moisture Expension-IS 13630(pt-3)) |
- |
2000 |
|
- |
| 6 table 5, ii e(Scratch hardness of surface -IS 13630(pt-13)) |
- |
500 |
|
- |
| 6 table 5, ii f(Coefficient of linear tharmal expansion from ambient temperature to100°C-IS 13630(pt-4) ) |
- |
1500 |
|
- |
| 6 table 5, ii g(Thermal shock resistance IS 13630(pt-5)) |
- |
1500 |
|
- |
| 6 table 5, ii h(Impact resistance-IS 13630(pt-14)) |
- |
1000 |
|
- |
| 6 table 5, ii j(Co-efficient of friction-tiles intended for used on floor ) |
- |
500 |
|
- |
| 6 table 5, ii k(Crazing resistance-IS 13630(pt-9)) |
- |
4000 |
|
- |
| 6 table 5, ii m(resistance to surface abrasion of glazed Tilles) |
- |
1500 |
|
- |
| 6 table 5, iii a(Resistance to staining of glazed Tilles-IS 13630(pt-8)) |
- |
1500 |
|
- |
| 6 table 5, iii b(Resistance to household chemicals and swimming pool water cleansers agents containing hydrofluoric acid and its compound-IS 13630(pt-8)) |
- |
1000 |
|
- |
| 6 table 5, iii c(Resistance to acid and alkalis (with the exception ofhydrofluoric acid and its
compounds – Glazed tiles-IS 13630(pt-8)) |
- |
1000 |
|
- |
| 6 table 6, i a (Length-IS 13630(pt-1)) |
- |
200 |
|
- |
| 6 table 6, i a (width-IS 13630(pt-1)) |
- |
200 |
|
- |
| 6 table 6, i b (Thickness-IS 13630(pt-1)) |
- |
200 |
|
- |
| 6 table 6, i c(Straigthness of side-IS 13630(pt-1)) |
- |
1000 |
|
- |
| 6 table 6, i d(Rectangularity-IS 13630(pt-1)) |
- |
1000 |
|
- |
| 6 table 6, i e(Surface flatness-IS 13630(pt-1)) |
- |
500 |
|
- |
| 6 table 6, i f(Surface quality-IS 13630(pt-1)) |
- |
200 |
|
- |
| 6 table 6, ii a(Water Absorption-IS 13630(pt-2) ) |
- |
1000 |
|
- |
| 6 table 6, ii b(Module of rupture -IS 13630(pt-6)) |
- |
2500 |
|
- |
| 6 table 6, ii c(Bending Strength-IS 13630(pt-6)) |
- |
1000 |
|
- |
| 6 table 6, ii d(Moisture Expension-IS 13630(pt-3)) |
- |
2000 |
|
- |
| 6 table 6, ii e(Scratch hardness of surface-IS 13630(pt-13) ) |
- |
500 |
|
- |
| 5 table 6, ii f(Resistance to surface abrasion of glazed Tilles) |
- |
1000 |
|
- |
| 6 table 6, ii g(Coefficient of linear tharmal expansion from ambient temperature to100°C-IS13630(pt-4) ) |
- |
1500 |
|
- |
| 6 table 6, ii h(Thermal shock resistance-IS13630(pt-5) ) |
- |
1500 |
|
- |
| 6 table 6, ii j(Crazing resistance-IS 13630(pt-9)) |
- |
4000 |
|
- |
| 6 table 6, ii k(Impact resistance-IS 13630(pt-14)) |
- |
1000 |
|
- |
| 6 table 6, ii m(Co-efficient of friction-tiles intended for used on floor ) |
- |
1000 |
|
- |
| 6 table 6, ii n(Forst resistance-IS 13630(pt-10)) |
- |
2000 |
|
- |
| 6 table 6, ii p(Resistance to deep abrasion of unglazed tiles) |
- |
1500 |
|
- |
| 6 table 6, iii a(Resistance to staining of glazed Tilles) |
- |
1200 |
|
- |
| 6 table 6, iii b(Resistance to household chemicals and swimming pool water cleansers agents containing hydrofluoric acid and its compound) |
- |
1000 |
|
- |
| 6 table 6, iii c(Resistance to acid and alkalis (with the exception of hydrofluoric acid and its
compounds – Glazed tiles) |
- |
1000 |
|
- |
| 6 table 7, i a (Length-IS 13630(pt-1)) |
- |
200 |
|
- |
| 6 table 7, i a (width-IS 13630(pt-1)) |
- |
200 |
|
- |
| 6 table 7, i b (Thickness-IS 13630(pt-1)) |
- |
200 |
|
- |
| 6 table 7, i c(Straigthness of side-IS 13630(pt-1)) |
- |
1000 |
|
- |
| 6 table 7, i d(Rectangularity-IS 13630(pt-1)) |
- |
1000 |
|
- |
| 6 table 7, i e(Surface flatness-IS 13630(pt-1)) |
- |
500 |
|
- |
| 6 table 7, i f(Surface quality-IS 13630(pt-1)) |
- |
500 |
|
- |
| 6 table 7, ii a(Water Absorption-IS 13630(pt-2) ) |
- |
1000 |
|
- |
| 6 table 7, ii b(Module of rupture-IS 13630(pt-6) ) |
- |
2500 |
|
- |
| 6 table 7, ii c(Bending Strength-IS 13630(pt-6)) |
- |
1000 |
|
- |
| 6 table 7, ii d(Moisture Expension-IS 13630(pt-3)) |
- |
2000 |
|
- |
| 6 table 7, ii e(Scratch hardness of surface-IS 13630(pt-13)) |
- |
500 |
|
- |
| 6 table 7, ii f(Resistance to surface abrasion of glazed Tilles) |
- |
1500 |
|
- |
| 6 table 7, ii g(Coefficient of linear tharmal expansion from ambient temperature to100°C-IS13630(pt-4) ) |
- |
1500 |
|
- |
| 6 table 7, ii h(Thermal shock resistance-IS13630(pt-5) ) |
- |
1500 |
|
- |
| 6 table 7, ii j(Crazing resistance-IS 13630(pt-9)) |
- |
4000 |
|
- |
| 6 table 7, ii k(Impact resistance-IS 13630(pt-14)) |
- |
1000 |
|
- |
| 6 table 7, ii m(Co-efficient of friction-tiles intended for used on floor ) |
- |
1000 |
|
- |
| 6 table 7, ii n(Forst resistance-IS 13630(pt-10)) |
- |
2000 |
|
- |
| 6 table 7, ii p(Resistance to deep abrasion of unglazed tiles) |
- |
1500 |
|
- |
| 6 table 7, iii a(Resistance to staining of glazed Tilles) |
- |
1200 |
|
- |
| 6 table 7, iii b(Resistance to household chemicals and swimming pool water cleansers agents containing hydrofluoric acid and its compound) |
- |
1000 |
|
- |
| 6 table 7, iii c(Resistance to acid and alkalis (with the exception of hydrofluoric acid and its
compounds – Glazed tiles) |
- |
1000 |
|
- |
| 6 table 8, i a (Length-IS 13630(pt-1)) |
- |
200 |
|
- |
| 6 table 8, i a (width-IS 13630(pt-1)) |
- |
200 |
|
- |
| 6 table 8, i b (Thickness-IS 13630(pt-1)) |
- |
200 |
|
- |
| 6 table 8, i c(Straigthness of side-IS 13630(pt-1)) |
- |
1000 |
|
- |
| 6 table 8, i d(Rectangularity-IS 13630(pt-1)) |
- |
1000 |
|
- |
| 6 table 8, i e(Surface flatness-IS 13630(pt-1)) |
- |
1000 |
|
- |
| 6 table 8, i f(Surface quality-IS 13630(pt-1)) |
- |
500 |
|
- |
| 6 table 8, ii a(Water Absorption-IS 13630(pt-6) ) |
- |
1000 |
|
- |
| 6 table 8, ii b(Module of rupture-IS 13630(pt-6) ) |
- |
2500 |
|
- |
| 6 table 8, ii c(Bending Strength-IS 13630(pt-6)) |
- |
1000 |
|
- |
| 6 table 8, ii d(Moisture Expension-IS 13630(pt-3)) |
- |
2000 |
|
- |
| 6 table 8, ii e(Scratch hardness of surface-IS 13630(pt-13) ) |
- |
500 |
|
- |
| 6 table 8, ii f(Resistance to surface abrasion of glazed Tilles) |
- |
1500 |
|
- |
| 6 table 8, ii g(Coefficient of linear tharmal expansion from ambient temperature to100°C-IS 13630(pt-4) ) |
- |
1500 |
|
- |
| 6 table 8, ii h(Thermal shock resistance-IS 13630(pt-5) ) |
- |
1500 |
|
- |
| 6 table 8, ii j(Crazing resistance-IS 13630(pt-9)) |
- |
4000 |
|
- |
| 6 table 8, ii k(Impact resistance-IS 13630(pt-14)) |
- |
1000 |
|
- |
| 6 table 8, ii m(Co-efficient of friction-tiles intended for used on floor ) |
- |
1000 |
|
- |
| 6 table 8, ii n(Forst resistance-IS 13630(pt-10)) |
- |
2000 |
|
- |
| 6 table 8, ii p(Resistance to deep abrasion of unglazed tiles) |
- |
1500 |
|
- |
| 6 table 8, ii q(Bulk Density-IS13630(pt-2)) |
- |
1000 |
|
- |
| 6 table 8, iii a(Resistance to staining of glazed Tilles) |
- |
1200 |
|
- |
| 6 table 8 iii b(Resistance to household chemicals and swimming pool water cleansers agents containing hydrofluoric acid and its compound) |
- |
1000 |
|
- |
| 6 table 8, iii c(Resistance to acid and alkalis (with the exception of hydrofluoric acid and its
compounds – Glazed tiles) |
- |
1000 |
|
- |
| 6 table 9, i a (Length-IS 13630(pt-1)) |
- |
200 |
|
- |
| 6 table 9, i a (width-IS 13630(pt-1)) |
- |
200 |
|
- |
| 6 table 9, i b (Thickness-IS 13630(pt-1)) |
- |
200 |
|
- |
| 6 table 9, i c(Straigthness of side-IS 13630(pt-1)) |
- |
1000 |
|
- |
| 6 table 9, i d(Rectangularity-IS 13630(pt-1)) |
- |
1000 |
|
- |
| 6 table 9, i e(Surface flatness-IS 13630(pt-1)) |
- |
500 |
|
- |
| 6 table 9, i f(Surface quality-IS 13630(pt-1)) |
- |
200 |
|
- |
| 6 table 9, ii a(Water Absorption-IS 13630(pt-6) ) |
- |
1000 |
|
- |
| 6 table 9, ii b(Module of rupture-IS 13630(pt-6) ) |
- |
2500 |
|
- |
| 6 table 9, ii c(Bending Strength-IS 13630(pt-6)) |
- |
1000 |
|
- |
| 6 table 9, ii d(Moisture Expension-IS 13630(pt-3)) |
- |
2000 |
|
- |
| 6 table 9, ii e(Scratch hardness of surface-IS 13630(pt-13) ) |
- |
500 |
|
- |
| 6 table 9, ii f(Resistance to surface abrasion of glazed Tilles) |
- |
1500 |
|
- |
| 6 table 9, ii g(Coefficient of linear tharmal expansion from ambient temperature to100°C ) |
- |
1500 |
|
- |
| 6 table 9, ii h(Thermal shock resistance-IS 13630(pt-5)) |
- |
1500 |
|
- |
| 6 table 9, ii j(Crazing resistance-IS 13630(pt-9)) |
- |
- |
|
- |
| 6 table 9, ii k(Impact resistance-IS 13630(pt-14)) |
- |
- |
|
- |
| 6 table 8, ii m(Co-efficient of friction-tiles intended for used on floor ) |
- |
- |
|
- |
| 6 table 9, ii n(Forst resistance-IS 13630(pt-10)) |
- |
- |
|
- |
| 6 table 9, ii p(Resistance to deep abrasion of unglazed tiles) |
- |
- |
|
- |
| 6 table 9, ii q(Bulk Density-) |
- |
- |
|
- |
| 6 table 9, iii a(Resistance to staining ) |
- |
- |
|
- |
| 6 table 9 iii b(Resistance to household chemicals and swimming pool water cleansers agents containing hydrofluoric acid and its compound) |
- |
- |
|
- |
| 6 table 9, iii c(Resistance to acid and alkalis (with the exception of hydrofluoric acid and its
compounds – Glazed tiles) |
- |
- |
|
- |
| 6.0, Table 5 - 9 & SI No. - 1E(3)(Warpage) |
- |
- |
|
- |
| 6.0, Table 5 - 9 & SI No. - 1E(2)(Edge Curveture) |
- |
- |
|
- |
| CLAUSE NO. 5.2(Shapes and Sizes) |
- |
- |
|
- |
| 5.3(Spacer Lug) |
- |
- |
|
- |
|
01 Dec, 2027 |
- Included w.e.f.21.08.2025 |
| 1848 |
EMC Testing and Compliance LLP, Gurugram
| 8141526
| IS 17633 (2022) |
Tables and Desks - Specification |
- |
25000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| CLAUSE 4(Design and workmanship) |
- |
500 |
|
- |
| ClAUSE 5(Dimensions) |
- |
500 |
|
- |
| CLAUSE 6(SURFACE PERFORMANCE REQUIRMENTS) |
- |
5000 |
|
- |
| CLAUSE 7.2.1(Stability Under Vertical Load) |
- |
1000 |
|
- |
| CLAUSE 7.2.1.1(Test for tables that can be set to a height of 950 mm or less) |
- |
1000 |
|
- |
| CLAUSE 7.2.1.2(" Test for Tables that can be set to a height greater
than 950 mm") |
- |
1000 |
|
- |
| CLAUSE 7.2.2(Stability with Extension Elements Open Place the table on the floor surface) |
- |
1000 |
|
- |
| CLAUSE 7.2.3(Stability Under Horizontal Load) |
- |
1000 |
|
- |
| CLAUSE 7.2.3.1(Test for tables that can be set to a height of 950 mm or less) |
- |
1000 |
|
- |
| CLAUSE 7.2.3.2(" Test for Tables that can be set to a height greater
than 950 mm") |
- |
1000 |
|
- |
| CLAUSE 7.3.1(Strength under Vertical Static Force) |
- |
2000 |
|
- |
| CLAUSE 7.3.1.1(Stated load) |
- |
1500 |
|
- |
| CLAUSE 7.3.1.2(For occasional heavy loads) |
- |
1500 |
|
- |
| CLAUSE 7.3.2(Strength under horizontal static force) |
- |
1500 |
|
- |
| CLAUSE 7.4.1(Durability under Vertical Force) |
- |
4000 |
|
- |
| CLAUSE 7.4.2(Durability of the Height Adjustment Mechanism) |
- |
4000 |
|
- |
| CLAUSE 7.5.1(Durability and Stiffness Under Horizontal Force) |
- |
7000 |
|
- |
| CLAUSE 7.5.2(Durability under Horizontal Force) |
- |
4000 |
|
- |
| CLAUSE 7.5.3(Stiffness of the Structure Under Horizontal Force) |
- |
2000 |
|
- |
| CLAUSE 7.6.1(Vertical Impact Test) |
- |
2000 |
|
- |
| CLAUSE 7.6.2(Vertical Impact Test for Glass Table Tops) |
- |
2000 |
|
- |
| CLAUSE 7.6.3(Vertical Impact Test for All Other Table Tops) |
- |
2000 |
|
- |
| CLAUSE 7.7(Deflection of Table Tops) |
- |
1500 |
|
- |
| CLAUSE 7.8(Durability of Tables with Castors) |
- |
7000 |
|
- |
| CLAUSE 7.9(Drop Test) |
- |
1500 |
|
- |
| Cl - 5(Dimensions) |
- |
0 |
|
- |
| Cl-6 (a)(Resistance to mechanical damage) |
- |
2500 |
|
- |
| Cl-6 (b)(Pencil hardness) |
- |
1000 |
|
- |
| Cl-6 (c)(Resistance to wet heat) |
- |
1500 |
|
- |
| Cl-6 (d)(Resistance to dry heat) |
- |
1500 |
|
- |
| Cl-6 (e)(Resistance to marking by cold liquids) |
- |
1500 |
|
- |
| Cl-6 (f)(Resistance to marking by cold oils and fats) |
- |
1500 |
|
- |
| Cl-6 (g)(Adhesive performance) |
- |
1500 |
|
- |
| Cl-7.2.1(Stability Under Vertical Load) |
- |
0 |
|
Repeated |
| Cl-7.2.2(Stability with Extension Elements Open) |
- |
0 |
|
Repeated |
| Cl-7.2.3(Stability Under Horizontal Load) |
- |
0 |
|
Repeated |
| Cl-7.3.1(Strength under Vertical Static Force) |
- |
0 |
|
Repeated |
| Cl-7.3.2(Strength under horizontal static force) |
- |
0 |
|
Repeated |
| Cl-7.4.1(Durability under Vertical Force) |
- |
0 |
|
Repeated |
| Cl-7.4.2(Durability of the Height Adjustment Mechanism) |
- |
0 |
|
Repeated |
| Cl-7.5.1(General) |
- |
0 |
|
Repeated |
| Cl-7.5.2(Durability under Horizontal Force) |
- |
0 |
|
Repeated |
| Cl-7.5.3(Stiffness of the Structure Under Horizontal Force) |
- |
0 |
|
Repeated |
| Cl-7.6.1(General) |
- |
0 |
|
Repeated |
| Cl-7.6.2(Vertical Impact Test for Glass Table Tops) |
- |
0 |
|
Repeated |
| Cl-7.6.3(Vertical Impact Test for All Other Table Tops) |
- |
0 |
|
Repeated |
| Cl-7.7(Deflection of Table Tops) |
- |
0 |
|
Repeated |
| Cl-7.8(Durability of Tables with Castors) |
- |
0 |
|
Repeated |
| Cl-7.9(Drop Test) |
- |
0 |
|
Repeated |
| Cl-9(Marking) |
- |
0 |
|
Repeated |
| 7.1(General test conditions) |
- |
0 |
|
Repeated |
| CLAUSE 4(Design and workmanship) |
- |
0 |
|
Repeated |
| ClAUSE 5(Dimensions) |
- |
0 |
|
Repeated |
| CLAUSE 6(SURFACE PERFORMANCE REQUIRMENTS) |
- |
0 |
|
Repeated |
| CLAUSE 7.2.1(Stability Under Vertical Load) |
- |
0 |
|
Repeated |
| CLAUSE 7.2.1.1(Test for tables that can be set to a height of 950 mm or less) |
- |
0 |
|
Repeated |
| CLAUSE 7.2.1.2(" Test for Tables that can be set to a height greater
than 950 mm") |
- |
0 |
|
Repeated |
| CLAUSE 7.2.2(Stability with Extension Elements Open Place the table on the floor surface) |
- |
0 |
|
Repeated |
| CLAUSE 7.2.3(Stability Under Horizontal Load) |
- |
0 |
|
Repeated |
| CLAUSE 7.2.3.1(Test for tables that can be set to a height of 950 mm or less) |
- |
0 |
|
Repeated |
| CLAUSE 7.2.3.2(" Test for Tables that can be set to a height greater
than 950 mm") |
- |
0 |
|
Repeated |
| CLAUSE 7.3.1(Strength under Vertical Static Force) |
- |
0 |
|
Repeated |
| CLAUSE 7.3.1.1(Stated load) |
- |
0 |
|
Repeated |
| CLAUSE 7.3.1.2(For occasional heavy loads) |
- |
0 |
|
Repeated |
| CLAUSE 7.3.2(Strength under horizontal static force) |
- |
0 |
|
Repeated |
| CLAUSE 7.4.1(Durability under Vertical Force) |
- |
0 |
|
Repeated |
| CLAUSE 7.4.2(Durability of the Height Adjustment Mechanism) |
- |
0 |
|
Repeated |
| CLAUSE 7.5.1(Durability and Stiffness Under Horizontal Force) |
- |
0 |
|
Repeated |
| CLAUSE 7.5.2(Durability under Horizontal Force) |
- |
0 |
|
Repeated |
| CLAUSE 7.5.3(Stiffness of the Structure Under Horizontal Force) |
- |
0 |
|
Repeated |
| CLAUSE 7.6.1(Vertical Impact Test) |
- |
0 |
|
Repeated |
| CLAUSE 7.6.2(Vertical Impact Test for Glass Table Tops) |
- |
0 |
|
Repeated |
| CLAUSE 7.6.3(Vertical Impact Test for All Other Table Tops) |
- |
0 |
|
Repeated |
| CLAUSE 7.7(Deflection of Table Tops) |
- |
0 |
|
Repeated |
| CLAUSE 7.8(Durability of Tables with Castors) |
- |
0 |
|
Repeated |
| CLAUSE 7.9(Drop Test) |
- |
0 |
|
Repeated |
| Cl - 5(Dimensions) |
- |
0 |
|
Repeated |
| Cl-6 (a)(Resistance to mechanical damage) |
- |
0 |
|
Repeated |
| Cl-6 (b)(Pencil hardness) |
- |
0 |
|
Repeated |
| Cl-6 (c)(Resistance to wet heat) |
- |
0 |
|
Repeated |
| Cl-6 (d)(Resistance to dry heat) |
- |
0 |
|
Repeated |
| Cl-6 (e)(Resistance to marking by cold liquids) |
- |
0 |
|
Repeated |
| Cl-6 (f)(Resistance to marking by cold oils and fats) |
- |
0 |
|
Repeated |
| Cl-6 (g)(Adhesive performance) |
- |
0 |
|
Repeated |
| Cl-7.2.1(Stability Under Vertical Load) |
- |
0 |
|
Repeated |
| Cl-7.2.2(Stability with Extension Elements Open) |
- |
0 |
|
Repeated |
| Cl-7.2.3(Stability Under Horizontal Load) |
- |
0 |
|
Repeated |
| Cl-7.3.1(Strength under Vertical Static Force) |
- |
0 |
|
Repeated |
| Cl-7.3.2(Strength under horizontal static force) |
- |
0 |
|
Repeated |
| Cl-7.4.1(Durability under Vertical Force) |
- |
0 |
|
Repeated |
| Cl-7.4.2(Durability of the Height Adjustment Mechanism) |
- |
0 |
|
Repeated |
| Cl-7.5.1(General) |
- |
0 |
|
Repeated |
| Cl-7.5.2(Durability under Horizontal Force) |
- |
0 |
|
Repeated |
| Cl-7.5.3(Stiffness of the Structure Under Horizontal Force) |
- |
0 |
|
Repeated |
| Cl-7.6.1(General) |
- |
0 |
|
Repeated |
| Cl-7.6.2(Vertical Impact Test for Glass Table Tops) |
- |
0 |
|
Repeated |
| Cl-7.6.3(Vertical Impact Test for All Other Table Tops) |
- |
0 |
|
Repeated |
| Cl-7.7(Deflection of Table Tops) |
- |
0 |
|
Repeated |
| Cl-7.8(Durability of Tables with Castors) |
- |
0 |
|
Repeated |
| Cl-7.9(Drop Test) |
- |
0 |
|
Repeated |
| Cl-9(Marking) |
- |
0 |
|
Repeated |
| 7.1(General test conditions) |
- |
0 |
|
Repeated |
| CLAUSE 4(Design and workmanship) |
- |
0 |
|
Repeated |
| ClAUSE 5(Dimensions) |
- |
0 |
|
Repeated |
| CLAUSE 6(SURFACE PERFORMANCE REQUIRMENTS) |
- |
0 |
|
Repeated |
| CLAUSE 7.2.1(Stability Under Vertical Load) |
- |
0 |
|
Repeated |
| CLAUSE 7.2.1.1(Test for tables that can be set to a height of 950 mm or less) |
- |
0 |
|
Repeated |
| CLAUSE 7.2.1.2(" Test for Tables that can be set to a height greater
than 950 mm") |
- |
0 |
|
Repeated |
| CLAUSE 7.2.2(Stability with Extension Elements Open Place the table on the floor surface) |
- |
0 |
|
- |
| CLAUSE 7.2.3(Stability Under Horizontal Load) |
- |
0 |
|
Repeated |
| CLAUSE 7.2.3.1(Test for tables that can be set to a height of 950 mm or less) |
- |
0 |
|
Repeated |
| CLAUSE 7.2.3.2(" Test for Tables that can be set to a height greater
than 950 mm") |
- |
0 |
|
Repeated |
| CLAUSE 7.3.1(Strength under Vertical Static Force) |
- |
0 |
|
Repeated |
| CLAUSE 7.3.1.1(Stated load) |
- |
0 |
|
Repeated |
| CLAUSE 7.3.1.2(For occasional heavy loads) |
- |
0 |
|
Repeated |
| CLAUSE 7.3.2(Strength under horizontal static force) |
- |
0 |
|
Repeated |
| CLAUSE 7.4.1(Durability under Vertical Force) |
- |
0 |
|
Repeated |
| CLAUSE 7.4.2(Durability of the Height Adjustment Mechanism) |
- |
0 |
|
Repeated |
| CLAUSE 7.5.1(Durability and Stiffness Under Horizontal Force) |
- |
0 |
|
Repeated |
| CLAUSE 7.5.2(Durability under Horizontal Force) |
- |
0 |
|
Repeated |
| CLAUSE 7.5.3(Stiffness of the Structure Under Horizontal Force) |
- |
0 |
|
Repeated |
| CLAUSE 7.6.1(Vertical Impact Test) |
- |
0 |
|
Repeated |
| CLAUSE 7.6.2(Vertical Impact Test for Glass Table Tops) |
- |
0 |
|
Repeated |
| CLAUSE 7.6.3(Vertical Impact Test for All Other Table Tops) |
- |
0 |
|
Repeated |
| CLAUSE 7.7(Deflection of Table Tops) |
- |
0 |
|
Repeated |
| CLAUSE 7.8(Durability of Tables with Castors) |
- |
0 |
|
Repeated |
| CLAUSE 7.9(Drop Test) |
- |
0 |
|
Repeated |
| Cl - 5(Dimensions) |
- |
0 |
|
Repeated |
| Cl-6 (a)(Resistance to mechanical damage) |
- |
0 |
|
Repeated |
| Cl-6 (b)(Pencil hardness) |
- |
0 |
|
Repeated |
| Cl-6 (c)(Resistance to wet heat) |
- |
0 |
|
Repeated |
| Cl-6 (d)(Resistance to dry heat) |
- |
0 |
|
Repeated |
| Cl-6 (e)(Resistance to marking by cold liquids) |
- |
0 |
|
Repeated |
| Cl-6 (f)(Resistance to marking by cold oils and fats) |
- |
0 |
|
Repeated |
| Cl-6 (g)(Adhesive performance) |
- |
0 |
|
Repeated |
| CLAUSE 4(Design and workmanship) |
- |
0 |
|
Repeated |
| ClAUSE 5(Dimensions) |
- |
0 |
|
Repeated |
| CLAUSE 6(SURFACE PERFORMANCE REQUIRMENTS) |
- |
0 |
|
Repeated |
| CLAUSE 7.2.1(Stability Under Vertical Load) |
- |
0 |
|
Repeated |
| CLAUSE 7.2.1.1(Test for tables that can be set to a height of 950 mm or less) |
- |
0 |
|
Repeated |
| CLAUSE 7.2.1.2(" Test for Tables that can be set to a height greater
than 950 mm") |
- |
0 |
|
Repeated |
| CLAUSE 7.2.2(Stability with Extension Elements Open Place the table on the floor surface) |
- |
0 |
|
Repeated |
| CLAUSE 7.2.3(Stability Under Horizontal Load) |
- |
0 |
|
Repeated |
| CLAUSE 7.2.3.1(Test for tables that can be set to a height of 950 mm or less) |
- |
0 |
|
Repeated |
| CLAUSE 7.2.3.2(" Test for Tables that can be set to a height greater
than 950 mm") |
- |
0 |
|
Repeated |
| CLAUSE 7.3.1(Strength under Vertical Static Force) |
- |
0 |
|
Repeated |
| CLAUSE 7.3.1.1(Stated load) |
- |
0 |
|
Repeated |
| CLAUSE 7.3.1.2(For occasional heavy loads) |
- |
0 |
|
Repeated |
| CLAUSE 7.3.2(Strength under horizontal static force) |
- |
0 |
|
Repeated |
| CLAUSE 7.4.1(Durability under Vertical Force) |
- |
0 |
|
Repeated |
| CLAUSE 7.4.2(Durability of the Height Adjustment Mechanism) |
- |
0 |
|
Repeated |
| CLAUSE 7.5.1(Durability and Stiffness Under Horizontal Force) |
- |
0 |
|
Repeated |
| CLAUSE 7.5.2(Durability under Horizontal Force) |
- |
0 |
|
Repeated |
| CLAUSE 7.5.3(Stiffness of the Structure Under Horizontal Force) |
- |
0 |
|
Repeated |
| CLAUSE 7.6.1(Vertical Impact Test) |
- |
0 |
|
Repeated |
| CLAUSE 7.6.2(Vertical Impact Test for Glass Table Tops) |
- |
0 |
|
Repeated |
| CLAUSE 7.6.3(Vertical Impact Test for All Other Table Tops) |
- |
0 |
|
Repeated |
| CLAUSE 7.7(Deflection of Table Tops) |
- |
0 |
|
Repeated |
| CLAUSE 7.8(Durability of Tables with Castors) |
- |
0 |
|
Repeated |
| CLAUSE 7.9(Drop Test) |
- |
0 |
|
Repeated |
| Cl - 5(Dimensions) |
- |
0 |
|
Repeated |
| Cl-6 (a)(Resistance to mechanical damage) |
- |
0 |
|
Repeated |
| Cl-6 (b)(Pencil hardness) |
- |
0 |
|
Repeated |
| Cl-6 (c)(Resistance to wet heat) |
- |
0 |
|
Repeated |
| Cl-6 (d)(Resistance to dry heat) |
- |
0 |
|
Repeated |
| Cl-6 (e)(Resistance to marking by cold liquids) |
- |
0 |
|
Repeated |
| Cl-6 (f)(Resistance to marking by cold oils and fats) |
- |
0 |
|
Repeated |
| Cl-6 (g)(Adhesive performance) |
- |
0 |
|
Repeated |
| Cl-7.2.1(Stability Under Vertical Load) |
- |
0 |
|
Repeated |
| Cl-7.2.2(Stability with Extension Elements Open) |
- |
0 |
|
Repeated |
| Cl-7.2.3(Stability Under Horizontal Load) |
- |
0 |
|
Repeated |
| Cl-7.3.1(Strength under Vertical Static Force) |
- |
0 |
|
Repeated |
| Cl-7.3.2(Strength under horizontal static force) |
- |
0 |
|
Repeated |
| Cl-7.4.1(Durability under Vertical Force) |
- |
0 |
|
Repeated |
| Cl-7.4.2(Durability of the Height Adjustment Mechanism) |
- |
0 |
|
Repeated |
| Cl-7.5.1(General) |
- |
0 |
|
Repeated |
| Cl-7.5.2(Durability under Horizontal Force) |
- |
0 |
|
Repeated |
| Cl-7.5.3(Stiffness of the Structure Under Horizontal Force) |
- |
0 |
|
Repeated |
| Cl-7.6.1(General) |
- |
0 |
|
Repeated |
| Cl-7.6.2(Vertical Impact Test for Glass Table Tops) |
- |
0 |
|
Repeated |
| Cl-7.6.3(Vertical Impact Test for All Other Table Tops) |
- |
0 |
|
Repeated |
| Cl-7.7(Deflection of Table Tops) |
- |
0 |
|
Repeated |
| Cl-7.8(Durability of Tables with Castors) |
- |
0 |
|
Repeated |
| Cl-7.9(Drop Test) |
- |
0 |
|
Repeated |
| Cl-9(Marking) |
- |
0 |
|
Repeated |
| 7.1(General test conditions) |
- |
0 |
|
Repeated |
|
19 Jul, 2027 |
- Included w.e.f 01.09.2025 |
| 1849 |
Classic Testing & Research Centre (B17), Noida
| 8180826
| IS 1475 (2024) |
Drinking Water Coolers - Specification (Fourth Revision) |
- |
50000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4(Classification) |
- |
5000 |
|
- |
| 5(Construction) |
- |
7000 |
|
- |
| 6.3(Cooling Capacity Test) |
- |
10000 |
|
- |
| 6.4(Maximum Operating Condition Test) |
- |
7000 |
|
- |
| 6.5(Pull Down Test) |
- |
5000 |
|
- |
| 9(Maximum Power Consumption Test) |
- |
7000 |
|
- |
| 10(Annual Energy Consumption Test) |
- |
10000 |
|
- |
| 11(Storage Capacity Test) |
- |
10000 |
|
- |
| 13(Functional Test) |
- |
5000 |
|
- |
| 14 a)(Protection against electric shock) |
- |
5000 |
|
- |
| 14 b)(High voltage (electric strength) test) |
- |
5000 |
|
- |
| 14 c)(Leakage current tests) |
- |
5000 |
|
- |
| 14 d)(Provision for earthing) |
- |
5000 |
|
- |
|
15 Oct, 2027 |
- Included w.e.f 11.08.2025 |
| 1850 |
Aaditech Test and Calibration Lab LLP
| 8179926
| IS 2312 (1967) |
Specification for propeller type AC ventilating fans (First Revision) |
There rated voltage not exceed 250V, ac for single phase or 440V ac for three phase. |
21000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 13.1(Marking) |
- |
1000 |
|
- |
| 13.1 (a)(Marking) |
- |
0 |
|
- |
| 13.1 (b)(Marking) |
- |
0 |
|
- |
| 13.1 (c)(Marking) |
- |
0 |
|
- |
| 13.1 (d)(Marking) |
- |
0 |
|
- |
| 13.1 (e)(Marking) |
- |
0 |
|
- |
| 13.1 (f)(Marking) |
- |
0 |
|
- |
| 13.1 (g)(Marking) |
- |
0 |
|
- |
| 13.1 (h)(Marking) |
- |
0 |
|
- |
| 13.1 (j)(Marking) |
- |
0 |
|
- |
| 13.2(Marking) |
- |
0 |
|
- |
| 13.4(Marking) |
- |
0 |
|
- |
| 3.1(Sizes ) |
- |
500 |
|
- |
| 4.1(Rated Voltage) |
- |
500 |
|
- |
| 5.1(Rated frequency) |
- |
500 |
|
- |
| 6.1(Design and General Construction) |
- |
500 |
|
- |
| 6.3(Design and General Construction) |
- |
0 |
|
- |
| 6.3(Design and General Construction) |
- |
0 |
|
- |
| 6.4(Design and General Construction) |
- |
0 |
|
- |
| 6.5(Design and General Construction) |
- |
0 |
|
- |
| 6.6(Design and General Construction) |
- |
0 |
|
- |
| 6.7(Design and General Construction) |
- |
0 |
|
- |
| 6.9(Design and General Construction) |
- |
0 |
|
- |
| 6.1(Design and General Construction) |
- |
0 |
|
- |
| 6.11(Design and General Construction) |
- |
0 |
|
- |
| 6.12(Design and General Construction) |
- |
0 |
|
- |
| 7.1(Design and General Construction) |
- |
0 |
|
- |
| 8.1(Design and General Construction) |
- |
0 |
|
- |
| 9(Design and General Construction) |
- |
0 |
|
- |
| 10.1(Starting ) |
- |
100 |
|
- |
| 11.1(Interchangeability) |
- |
1000 |
|
- |
| 14.2 & 15.1(Air Delivery) |
- |
3000 |
|
- |
| 14.3.A(Temperature-Rise (for motors)) |
- |
2000 |
|
- |
| 14.3.A(Temperature-Rise (for motors)) |
- |
0 |
|
- |
| 14.3.A(Temperature-Rise (for motors)) |
- |
0 |
|
- |
| 14.3.A(Temperature-Rise (for motors)) |
- |
0 |
|
- |
| 14.3.B(Temperature-Rise (for regulators)) |
- |
1000 |
|
- |
| 14.3.B(Temperature-Rise (for regulators)) |
- |
0 |
|
- |
| 14.3.B(Moistureproofness (for regulators only)) |
- |
3000 |
|
- |
| 14.3.B(Moistureproofness (for regulators only)) |
- |
0 |
|
- |
| 14.5(Mechanical Endurance (for regulators only)) |
- |
2000 |
|
- |
| 14.1 & 14.6(Power factor) |
- |
500 |
|
- |
| 14.7(ac leakage) |
- |
500 |
|
- |
| 14.8(High voltage test) |
- |
500 |
|
- |
| 14.9(Insulation-Resistance) |
- |
500 |
|
- |
| 14.1(Earthing continuity) |
- |
500 |
|
- |
| 14.11 & 15.1(Electrical Input) |
- |
500 |
|
- |
| 14.12 & 16(Fan Speed) |
- |
500 |
|
- |
| 13.1(Marking) |
- |
0 |
|
- |
| 13.1 (a)(Marking) |
- |
0 |
|
- |
| 13.1 (b)(Marking) |
- |
0 |
|
- |
| 13.1 (c)(Marking) |
- |
0 |
|
- |
| 13.1 (d)(Marking) |
- |
0 |
|
- |
| 13.1 (e)(Marking) |
- |
0 |
|
- |
| 13.1 (f)(Marking) |
- |
0 |
|
- |
| 13.1 (g)(Marking) |
- |
0 |
|
- |
| 13.1 (h)(Marking) |
- |
0 |
|
- |
| 13.1 (j)(Marking) |
- |
0 |
|
- |
| 13.2(Marking) |
- |
0 |
|
- |
| 13.4(Marking) |
- |
0 |
|
- |
| 3.1(Sizes ) |
- |
0 |
|
- |
| 4.1(Rated Voltage) |
- |
0 |
|
- |
| 5.1(Rated frequency) |
- |
0 |
|
- |
| 6.1(Design and General Construction) |
- |
0 |
|
- |
| 6.3(Design and General Construction) |
- |
0 |
|
- |
| 6.3(Design and General Construction) |
- |
0 |
|
- |
| 6.4(Design and General Construction) |
- |
0 |
|
- |
| 6.5(Design and General Construction) |
- |
0 |
|
- |
| 6.6(Design and General Construction) |
- |
0 |
|
- |
| 6.7(Design and General Construction) |
- |
0 |
|
- |
| 6.9(Design and General Construction) |
- |
0 |
|
- |
| 6.1(Design and General Construction) |
- |
0 |
|
- |
| 6.11(Design and General Construction) |
- |
0 |
|
- |
| 6.12(Design and General Construction) |
- |
0 |
|
- |
| 7.1(Design and General Construction) |
- |
0 |
|
- |
| 8.1(Design and General Construction) |
- |
0 |
|
- |
| 9(Design and General Construction) |
- |
0 |
|
- |
| 10.1(Starting ) |
- |
0 |
|
- |
| 11.1(Interchangeability) |
- |
0 |
|
- |
| 14.2 & 15.1(Air Delivery) |
- |
0 |
|
- |
| 14.3(Temperature-Rise) |
- |
0 |
|
- |
| 14.3(Temperature-Rise) |
- |
0 |
|
- |
| 14.3(Temperature-Rise) |
- |
0 |
|
- |
| 14.3(Temperature-Rise) |
- |
0 |
|
- |
| 14.3(Temperature-Rise) |
- |
0 |
|
- |
| 14.3(Temperature-Rise) |
- |
0 |
|
- |
| 14.3(Temperature-Rise) |
- |
0 |
|
- |
| 14.4(Moistureproofness (for regulators only)) |
- |
0 |
|
- |
| 14.4(Moistureproofness (for regulators only)) |
- |
0 |
|
- |
| 14.5(Mechanical Endurance (for regulators only)) |
- |
0 |
|
- |
| 14.1 & 14.6(Power factor) |
- |
0 |
|
- |
| 14.7(ac leakage) |
- |
0 |
|
- |
| 14.8(High voltage test) |
- |
0 |
|
- |
| 14.9(Insulation-Resistance) |
- |
0 |
|
- |
| 14.1(Earthing continuity) |
- |
0 |
|
- |
| 14.11 & 15.1(Electrical Input) |
- |
0 |
|
- |
| 14.12 & 16(Fan Speed) |
- |
0 |
|
- |
| 14.13(Flash Test) |
- |
0 |
|
- |
| 12(Silent Operation) |
- |
0 |
|
- |
| Cl-16(Tolerances on ratings) |
- |
0 |
|
- |
| 13.1(Marking) |
- |
0 |
|
- |
| 13.1 (a)(Marking) |
- |
0 |
|
- |
| 13.1 (b)(Marking) |
- |
0 |
|
- |
| 13.1 (c)(Marking) |
- |
0 |
|
- |
| 13.1 (d)(Marking) |
- |
0 |
|
- |
| 13.1 (e)(Marking) |
- |
0 |
|
- |
| 13.1 (f)(Marking) |
- |
0 |
|
- |
| 13.1 (g)(Marking) |
- |
0 |
|
- |
| 13.1 (h)(Marking) |
- |
0 |
|
- |
| 13.1 (j)(Marking) |
- |
0 |
|
- |
| 13.2(Marking) |
- |
0 |
|
- |
| 13.4(Marking) |
- |
0 |
|
- |
| 3.1(Sizes ) |
- |
0 |
|
- |
| 4.1(Rated Voltage) |
- |
0 |
|
- |
| 5.1(Rated frequency) |
- |
0 |
|
- |
| 6.1(Design and General Construction) |
- |
0 |
|
- |
| 6.3(Design and General Construction) |
- |
0 |
|
- |
| 6.3(Design and General Construction) |
- |
0 |
|
- |
| 6.4(Design and General Construction) |
- |
0 |
|
- |
| 6.5(Design and General Construction) |
- |
0 |
|
- |
| 6.6(Design and General Construction) |
- |
0 |
|
- |
| 6.7(Design and General Construction) |
- |
0 |
|
- |
| 6.9(Design and General Construction) |
- |
0 |
|
- |
| 6.1(Design and General Construction) |
- |
0 |
|
- |
| 6.11(Design and General Construction) |
- |
0 |
|
- |
| 6.12(Design and General Construction) |
- |
0 |
|
- |
| 7.1(Design and General Construction) |
- |
0 |
|
- |
| 8.1(Design and General Construction) |
- |
0 |
|
- |
| 9(Design and General Construction) |
- |
0 |
|
- |
| 10.1(Starting ) |
- |
0 |
|
- |
| 11.1(Interchangeability) |
- |
0 |
|
- |
| 14.2 & 15.1(Air Delivery) |
- |
0 |
|
- |
| 14.3.A(Temperature-Rise (for motors)) |
- |
0 |
|
- |
| 14.3.A(Temperature-Rise (for motors)) |
- |
0 |
|
- |
| 14.3.A(Temperature-Rise (for motors)) |
- |
0 |
|
- |
| 14.3.A(Temperature-Rise (for motors)) |
- |
0 |
|
- |
| 14.3.B(Temperature-Rise (for regulators)) |
- |
0 |
|
- |
| 14.3.B(Temperature-Rise (for regulators)) |
- |
0 |
|
- |
| 14.3.B(Moistureproofness (for regulators only)) |
- |
0 |
|
- |
| 14.3.B(Moistureproofness (for regulators only)) |
- |
0 |
|
- |
| 14.5(Mechanical Endurance (for regulators only)) |
- |
0 |
|
- |
| 14.1 & 14.6(Power factor) |
- |
0 |
|
- |
| 14.7(ac leakage) |
- |
0 |
|
- |
| 14.8(High voltage test) |
- |
0 |
|
- |
| 14.9(Insulation-Resistance) |
- |
0 |
|
- |
| 14.1(Earthing continuity) |
- |
0 |
|
- |
| 14.11 & 15.1(Electrical Input) |
- |
0 |
|
- |
| 14.12 & 16(Fan Speed) |
- |
0 |
|
- |
| 13.1(Marking) |
- |
0 |
|
- |
| 13.1 (a)(Marking) |
- |
0 |
|
- |
| 13.1 (b)(Marking) |
- |
0 |
|
- |
| 13.1 (c)(Marking) |
- |
0 |
|
- |
| 13.1 (d)(Marking) |
- |
0 |
|
- |
| 13.1 (e)(Marking) |
- |
0 |
|
- |
| 13.1 (f)(Marking) |
- |
0 |
|
- |
| 13.1 (g)(Marking) |
- |
0 |
|
- |
| 13.1 (h)(Marking) |
- |
0 |
|
- |
| 13.1 (j)(Marking) |
- |
0 |
|
- |
| 13.2(Marking) |
- |
0 |
|
- |
| 13.4(Marking) |
- |
0 |
|
- |
| 3.1(Sizes ) |
- |
0 |
|
- |
| 4.1(Rated Voltage) |
- |
0 |
|
- |
| 5.1(Rated frequency) |
- |
0 |
|
- |
| 6.1(Design and General Construction) |
- |
0 |
|
- |
| 6.3(Design and General Construction) |
- |
0 |
|
- |
| 6.3(Design and General Construction) |
- |
0 |
|
- |
| 6.4(Design and General Construction) |
- |
0 |
|
- |
| 6.5(Design and General Construction) |
- |
0 |
|
- |
| 6.6(Design and General Construction) |
- |
0 |
|
- |
| 6.7(Design and General Construction) |
- |
0 |
|
- |
| 6.9(Design and General Construction) |
- |
0 |
|
- |
| 6.1(Design and General Construction) |
- |
0 |
|
- |
| 6.11(Design and General Construction) |
- |
0 |
|
- |
| 6.12(Design and General Construction) |
- |
0 |
|
- |
| 7.1(Design and General Construction) |
- |
0 |
|
- |
| 8.1(Design and General Construction) |
- |
0 |
|
- |
| 9(Design and General Construction) |
- |
0 |
|
- |
| 10.1(Starting ) |
- |
0 |
|
- |
| 11.1(Interchangeability) |
- |
0 |
|
- |
| 14.2 & 15.1(Air Delivery) |
- |
0 |
|
- |
| 14.3(Temperature-Rise) |
- |
0 |
|
- |
| 14.3(Temperature-Rise) |
- |
0 |
|
- |
| 14.3(Temperature-Rise) |
- |
0 |
|
- |
| 14.3(Temperature-Rise) |
- |
0 |
|
- |
| 14.3(Temperature-Rise) |
- |
0 |
|
- |
| 14.3(Temperature-Rise) |
- |
0 |
|
- |
| 14.3(Temperature-Rise) |
- |
0 |
|
- |
| 14.4(Moistureproofness (for regulators only)) |
- |
0 |
|
- |
| 14.4(Moistureproofness (for regulators only)) |
- |
0 |
|
- |
| 14.5(Mechanical Endurance (for regulators only)) |
- |
0 |
|
- |
| 14.1 & 14.6(Power factor) |
- |
0 |
|
- |
| 14.7(ac leakage) |
- |
0 |
|
- |
| 14.8(High voltage test) |
- |
0 |
|
- |
| 14.9(Insulation-Resistance) |
- |
0 |
|
- |
| 14.1(Earthing continuity) |
- |
0 |
|
- |
| 14.11 & 15.1(Electrical Input) |
- |
0 |
|
- |
| 14.12 & 16(Fan Speed) |
- |
0 |
|
- |
| 14.13(Flash Test) |
- |
0 |
|
- |
| 12(Silent Operation) |
- |
0 |
|
- |
| Cl-16(Tolerances on ratings) |
- |
0 |
|
- |
|
28 Aug, 2027 |
- Included w.e.f. 18.08.2025 |
| 1851 |
Rajkot Metlab Services LLP, Rajkot
| 7183706
| IS 12427 (2001) |
Fasteners - Threaded steel fasteners - Hexagon head transmission tower bolts - Specification (First Revision) |
- |
23900 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl 9(Designation) |
- |
1000 |
|
- |
| Cl 3.1, Cl 3.2, Fig-1, Table-1 & Table-2(Dimensions) |
- |
2000 |
|
- |
| Cl 3.3, IS 4218(Pt 1 to 4) & IS 2334(Threads) |
- |
2000 |
|
- |
| Cl 5.1 & IS 14394(Nuts) |
- |
1000 |
|
- |
| Cl 5.2, IS 2016 & IS 4759(Washers) |
- |
1000 |
|
- |
| Cl 6.1 & IS 1367(Pt 3)(Bolt Tensile,Proof,Wedge Loading,Hardness Test) |
- |
5000 |
|
- |
| Cl 6.2(Bolt Shear Strength) |
- |
5000 |
|
- |
| Cl 7 & IS 1367(Pt 13)(Finish) |
- |
5000 |
|
- |
| Cl 8 & IS 1367(Pt 9/Sec1)(General Requirements) |
- |
1000 |
|
- |
| (Cl 8)(General Requirements) |
- |
1000 |
|
- |
| (Cl 7)(Finish) |
- |
1000 |
|
- |
| (Cl 7)(Finish) |
- |
1000 |
|
- |
| (Cl 6.2)(Shear Strength ) |
- |
1000 |
|
- |
| (Cl 9.15)(Mechanical Properties) |
- |
4000 |
|
- |
| (Cl 9.14)(Mechanical Properties) |
- |
4000 |
|
- |
| (Cl 9.13)(Mechanical Properties) |
- |
4000 |
|
- |
| (Cl 9.12)(Mechanical Properties) |
- |
4000 |
|
- |
| (Cl 9.11)(Mechanical Properties) |
- |
4000 |
|
- |
| (Cl 9.10)(Mechanical Properties) |
- |
4000 |
|
- |
| (Cl 8.3)(Mechanical Properties) |
- |
4000 |
|
- |
| (Cl 9.9)(Mechanical Properties) |
- |
4000 |
|
- |
| (Cl 9.8)(Mechanical Properties) |
- |
4000 |
|
- |
| (Cl 9.7) (Mechanical Properties) |
- |
4000 |
|
- |
| (Cl 9.7) (Mechanical Properties) |
- |
4000 |
|
- |
| (Cl 9.7) (Mechanical Properties) |
- |
4000 |
|
- |
| (Cl 9.7) (Mechanical Properties) |
- |
4000 |
|
- |
| (Cl 9.6)(Mechanical Properties) |
- |
4000 |
|
- |
| (Cl 9.5)(Mechanical Properties) |
- |
4000 |
|
- |
| (Cl 9.4)(Mechanical Properties) |
- |
4000 |
|
- |
| (Cl 9.3)(Mechanical Properties) |
- |
4000 |
|
- |
| (Cl 9.3)(Mechanical Properties) |
- |
4000 |
|
- |
| (Cl 9.3)(Mechanical Properties) |
- |
4000 |
|
- |
| (Cl 9.2)(Mechanical Properties) |
- |
4000 |
|
- |
| (Cl 9.1)(Mechanical Properties) |
- |
4000 |
|
- |
| Cl 6.1 & IS 1367(Pt 3)(Mechanical Properties) |
- |
4000 |
|
- |
| (Cl 5)(Matching Nuts & Washers) |
- |
100 |
|
- |
| (Cl 5)(Matching Nuts & Washers) |
- |
100 |
|
- |
| (Cl 3.3)(Threads) |
- |
2000 |
|
- |
| Cl 3 Table-1 & Table-2(Dimensions) |
- |
2000 |
|
- |
| Cl 3 Table-1 & Table-2(Dimensions) |
- |
2000 |
|
- |
| Cl 3 Table-1 & Table-2(Dimensions) |
- |
2000 |
|
- |
| Cl 3 Table-1 & Table-2(Dimensions) |
- |
2000 |
|
- |
| Cl 3 Table-1 & Table-2(Dimensions) |
- |
2000 |
|
- |
| Cl 3 Table-1 & Table-2(Dimensions) |
- |
2000 |
|
- |
| Cl 3 Table-1 & Table-2(Dimensions) |
- |
2000 |
|
- |
| Cl 3 Table-1 & Table-2(Dimensions) |
- |
2000 |
|
- |
| Cl 3 Table-1 & Table-2(Dimensions) |
- |
2000 |
|
- |
| Cl 3 Table-1 & Table-2(Dimensions) |
- |
2000 |
|
- |
| Cl 3 Table-1 & Table-2(Dimensions) |
- |
2000 |
|
- |
| Cl 3 Table-1 & Table-2(Dimensions) |
- |
2000 |
|
- |
| Cl 3 Table-1 & Table-2(Dimensions) |
- |
2000 |
|
- |
| Cl 3 Table-1 & Table-2(Dimensions) |
- |
2000 |
|
- |
| Cl 3 Table-1 & Table-2(Dimensions) |
- |
2000 |
|
- |
| Cl 3 Table-1 & Table-2(Dimensions) |
- |
2000 |
|
- |
| Cl 9(Designation) |
- |
100 |
|
- |
|
12 Jan, 2028 |
- Included w.e.f 01.09.2025 |
| 1852 |
Rajkot Metlab Services LLP, Rajkot
| 7183706
| IS 9550 (2024) |
Bright Steel Bars â Specification (Second Revision) |
- |
12800 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl-4(Supply of material and product designation) |
- |
100 |
|
- |
| Cl-6(Chemical Composition) |
- |
5000 |
|
- |
| Cl-7(mechanical properties) |
- |
5000 |
|
- |
| Cl-8.1(Dimensions) |
- |
1000 |
|
- |
| Cl-8.2.1, Table-1(Cold drawn or heattreated and cold drawn) |
- |
1000 |
|
- |
| Cl-8.2.1, Table-1(Cold drawn, heat treated) |
- |
1000 |
|
- |
| Cl-8.2.1, Table-1(Peeled/turned) |
- |
1000 |
|
- |
| Cl-8.2.1, Table-1(Polished) |
- |
1000 |
|
- |
| Cl-8.2.1.1(Tolerances on dimensions) |
- |
1000 |
|
- |
| Cl-8.2.2, Table-2 (i)(Manufacturing lengtha) |
- |
1000 |
|
- |
| Cl-8.2.2, Table-2 (ii)(Stock lengtha) |
- |
1000 |
|
- |
| Cl-8.2.2, Table-2 (iii)(Cut to length) |
- |
1000 |
|
- |
| Cl-9(Surface condiotn) |
- |
1000 |
|
- |
| Cl-14(Marking) |
- |
1000 |
|
- |
| Clause. 6.0(chemical composition) |
- |
5000 |
|
- |
| Clause. 6.0(Sillicon) |
- |
1000 |
|
- |
| Clause. 6.0(Carbon) |
- |
1000 |
|
- |
| Clause. 6.0(Copper) |
- |
1000 |
|
- |
| Clause. 6.0(Manganese) |
- |
1000 |
|
- |
| Clause. 6.0(Molybdenum) |
- |
1000 |
|
- |
| Clause. 6.0(Chromium) |
- |
1000 |
|
- |
| Clause. 6.0(Nickel) |
- |
1000 |
|
- |
| Clause. 6.0(Sulphur) |
- |
1000 |
|
- |
| Clause. 6.0(Phosphorus) |
- |
1000 |
|
- |
| Clause. 6.0(Vanadium) |
- |
1000 |
|
- |
| Clause. 6.0(Titanium) |
- |
1000 |
|
- |
| Clause. 6.0(Boron) |
- |
1000 |
|
- |
| Clause. 6.0(Aluminium) |
- |
1000 |
|
- |
| Clause. 7.0(Brinell Hardness) |
- |
2000 |
|
- |
| Clause. 7.0(Tensile test) |
- |
1000 |
|
- |
| Clause. 7.0(Yeild stress) |
- |
1000 |
|
- |
| Clause. 7.0(Elongation) |
- |
1000 |
|
- |
| Clause. 8.0(Dimension) |
- |
1000 |
|
- |
| Clause. 8.0(Tolerence) |
- |
1000 |
|
- |
| clause. 9.0(Surface condition) |
- |
1000 |
|
- |
| clause. 9.0(Decarburization) |
- |
1000 |
|
- |
| clause.-10.0(Sampling) |
- |
1000 |
|
- |
| clause.- 11.0(other tests) |
- |
5000 |
|
- |
| Clause. -12.0(Retest) |
- |
0 |
|
- |
| Clasue.- 13.0(Surface Protection) |
- |
1000 |
|
- |
| Clasue.- 14.0(Marking) |
- |
100 |
|
- |
|
12 Jan, 2028 |
- Included w.e.f. 22.09.2025 |
| 1853 |
EKO PRO ENGINEERS PRIVATE LIMITED (32/41), GHAZIABAD
| 9179706
| IS 13893 (1994) |
Polyurethane soles semirigid - specification |
ALL |
6000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4.3.2(Ageing test) |
- |
500 |
|
- |
| 4.3(Ross Flex test) |
- |
500 |
|
- |
| 4.3(Flexural strength ) |
- |
500 |
|
- |
| 4.3(Abrasion Resistance) |
- |
500 |
|
- |
| 4.3(Elongation at break) |
- |
500 |
|
- |
| 4.3(Tensile Strength ) |
- |
500 |
|
- |
| 4.3(Hardness Shore(A)) |
- |
500 |
|
- |
| 4.3(Relative density ) |
- |
500 |
|
- |
| 4.2(Thickness ) |
- |
300 |
|
- |
| 4.1(Design) |
- |
500 |
|
- |
| 5, 5.1, 5.2(Packing And Marking) |
- |
400 |
|
- |
| Cl.5, 5.1, 5.2(Packing And Marking) |
- |
300 |
|
- |
| 4.2 (Amendment 2)(Thickness) |
- |
400 |
|
- |
| 4.3.1 Table 1 i) (Amendment 2)(Relative Density) |
- |
500 |
|
- |
| 4.3.1 Table 1 iii) (Amendment 2)(Abrasion Resistance at applied force of 10 N) |
- |
500 |
|
- |
| 4.3.1 Table 1 iv) (Amendment 2)(Flexing Resistance, Bennewart method) |
- |
500 |
|
- |
| 4.3.1 Table 1 v) (Amendment 2)(Hydrolysis Resistance, cut growth after 150000 flexes) |
- |
500 |
|
- |
| 4.3.1 Table 1 vi) (Amendment 2)(Tensile Strength) |
- |
500 |
|
- |
| 4.3.1 Table 1 vii) (Amendment 2)(Elongation at break) |
- |
500 |
|
- |
| 4.3.1 Table 1 viii) (Amendment 2)(Tear Strength (average force)) |
- |
500 |
|
- |
| 4.3.1 Table 1 ii) (Amendment 2)(Hardness, degree, Shore A) |
- |
500 |
|
- |
| 4.3.2(Ageing test) |
- |
500 |
|
- |
| 4.3(Ross Flex test) |
- |
700 |
|
- |
| 4.3(Flexural strength ) |
- |
700 |
|
- |
| 4.3(Abrasion Resistance) |
- |
500 |
|
- |
| 4.3(Elongation at break) |
- |
500 |
|
- |
| 4.3(Tensile Strength ) |
- |
500 |
|
- |
| 4.3(Hardness Shore(A)) |
- |
500 |
|
- |
| 4.3(Relative density ) |
- |
500 |
|
- |
| 4.2(Thickness ) |
- |
500 |
|
- |
| 4.1(Design) |
- |
500 |
|
- |
| 5, 5.1, 5.2(Packing And Marking) |
- |
500 |
|
- |
| Cl.5, 5.1, 5.2(Packing And Marking) |
- |
500 |
|
- |
| 4.2 (Amendment 2)(Thickness) |
- |
500 |
|
- |
| 4.3.1 Table 1 i) (Amendment 2)(Relative Density) |
- |
500 |
|
- |
| 4.3.1 Table 1 iii) (Amendment 2)(Abrasion Resistance at applied force of 10 N) |
- |
500 |
|
- |
| 4.3.1 Table 1 iv) (Amendment 2)(Flexing Resistance, Bennewart method) |
- |
500 |
|
- |
| 4.3.1 Table 1 v) (Amendment 2)(Hydrolysis Resistance, cut growth after 150000 flexes) |
- |
500 |
|
- |
| 4.3.1 Table 1 vi) (Amendment 2)(Tensile Strength) |
- |
500 |
|
- |
| 4.3.1 Table 1 vii) (Amendment 2)(Elongation at break) |
- |
500 |
|
- |
| 4.3.1 Table 1 viii) (Amendment 2)(Tear Strength (average force)) |
- |
500 |
|
- |
| 4.3.1 Table 1 ii) (Amendment 2)(Hardness, degree, Shore A) |
- |
500 |
|
- |
| 4.3.2(Ageing test) |
- |
- |
|
- |
| 4.3(Ross Flex test) |
- |
- |
|
- |
| 4.3(Flexural strength ) |
- |
- |
|
- |
| 4.3(Abrasion Resistance) |
- |
- |
|
- |
| 4.3(Elongation at break) |
- |
- |
|
- |
| 4.3(Tensile Strength ) |
- |
- |
|
- |
| 4.3(Hardness Shore(A)) |
- |
- |
|
- |
| 4.3(Relative density ) |
- |
- |
|
- |
| 4.2(Thickness ) |
- |
- |
|
- |
| 4.1(Design) |
- |
- |
|
- |
| 5, 5.1, 5.2(Packing And Marking) |
- |
- |
|
- |
| Cl.5, 5.1, 5.2(Packing And Marking) |
- |
- |
|
- |
| 4.2 (Amendment 2)(Thickness) |
- |
- |
|
- |
| 4.3.1 Table 1 i) (Amendment 2)(Relative Density) |
- |
- |
|
- |
| 4.3.1 Table 1 iii) (Amendment 2)(Abrasion Resistance at applied force of 10 N) |
- |
- |
|
- |
| 4.3.1 Table 1 iv) (Amendment 2)(Flexing Resistance, Bennewart method) |
- |
- |
|
- |
| 4.3.1 Table 1 v) (Amendment 2)(Hydrolysis Resistance, cut growth after 150000 flexes) |
- |
- |
|
- |
| 4.3.1 Table 1 vi) (Amendment 2)(Tensile Strength) |
- |
- |
|
- |
| 4.3.1 Table 1 vii) (Amendment 2)(Elongation at break) |
- |
- |
|
- |
| 4.3.1 Table 1 viii) (Amendment 2)(Tear Strength (average force)) |
- |
- |
|
- |
| 4.3.1 Table 1 ii) (Amendment 2)(Hardness, degree, Shore A) |
- |
- |
|
- |
|
26 Aug, 2027 |
- Included w.e.f 08.12.2025 |
| 1854 |
SHRI KRISHNA TEST HOUSE PVT LTD (142)
| 8185606
| IS 11241 (2024) |
Portable Liquefied Petroleum Gas Appliances Operating at Vapour Pressure - Specification (FIRST REVISION) |
ALL |
40000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl-5.1(General) |
- |
40000 |
|
- |
| Cl-5.2(Adjustment of the Burner) |
- |
40000 |
|
- |
| Cl-5.3(Materials) |
- |
40000 |
|
- |
| Cl-5.4(Assembly, Cleaning, and Maintenance) |
- |
40000 |
|
- |
| Cl-5.5(Strength and Stability) |
- |
40000 |
|
- |
| Cl-5.6(Soundness of the Gas Circuit Assembly) |
- |
40000 |
|
- |
| Cl-5.7(Connections) |
- |
40000 |
|
- |
| Cl-5.8(Transport, Fixing and Mobility Devices) |
- |
40000 |
|
- |
| Cl-5.9(Taps) |
- |
40000 |
|
- |
| Cl-5.10(Control Handles) |
- |
40000 |
|
- |
| Cl-5.11(Injectors) |
- |
40000 |
|
- |
| Cl-5.12(Ignition Devices) |
- |
40000 |
|
- |
| Cl-5.13(Flame Supervision Devices) |
- |
40000 |
|
- |
| Cl-5.14(Burners and Radiant Elements) |
- |
40000 |
|
- |
| Cl-5.15(Grids) |
- |
40000 |
|
- |
| Cl-5.16(Turnspit) |
- |
40000 |
|
- |
| Cl-5.17(Fireguards for Heating Appliances) |
- |
40000 |
|
- |
| Cl-5.18(Locations and Compartments for Cartridge or Gas Cylinder) |
- |
40000 |
|
- |
| Cl-5.19(Verification of the Heat Inputs) |
- |
40000 |
|
- |
| Cl-5.20(Resistance to Overheating) |
- |
40000 |
|
- |
| Cl-5.21(Temperature of Various Parts of the Appliance) |
- |
40000 |
|
- |
| Cl-5.22(Temperature of Panels (Floors, Walls or Ceilings)) |
- |
40000 |
|
- |
| Cl-5.23(Ignition, Cross Lighting and Flame Stability) |
- |
40000 |
|
- |
| Cl-5.24(Resistance to Draught) |
- |
40000 |
|
- |
| Cl-5.25(Resistance to Liquid Spillage) |
- |
40000 |
|
- |
| Cl-5.26(Combustion) |
- |
40000 |
|
- |
| Cl-5.27(Accumulation of Un-Burnt Gas) |
- |
40000 |
|
- |
| Cl-5.28(Safety at High Temperature) |
- |
40000 |
|
- |
| Cl-5.29(Shooting – Condensation) |
- |
40000 |
|
- |
| Cl-5.30(Rational Use of Energy) |
- |
40000 |
|
- |
| Cl-5.30.1.2(Uncovered burners) |
- |
40000 |
|
- |
| Cl-5.30.1.3(Covered burners) |
- |
40000 |
|
- |
| Cl-5.31(Durability of Markings) |
- |
40000 |
|
- |
| Cl-5.32(Strength and Endurance Requirements) |
- |
40000 |
|
- |
| Cl-5.1(General) |
- |
40000 |
|
- |
| Cl-5.2(Adjustment of the Burner) |
- |
40000 |
|
- |
| Cl-5.3(Materials) |
- |
40000 |
|
- |
| Cl-5.4(Assembly, Cleaning, and Maintenance) |
- |
40000 |
|
- |
| Cl-5.5(Strength and Stability) |
- |
40000 |
|
- |
| Cl-5.6(Soundness of the Gas Circuit Assembly) |
- |
40000 |
|
- |
| Cl-5.7(Connections) |
- |
40000 |
|
- |
| Cl-5.8(Transport, Fixing and Mobility Devices) |
- |
40000 |
|
- |
| Cl-5.9(Taps) |
- |
40000 |
|
- |
| Cl-5.10(Control Handles) |
- |
40000 |
|
- |
| Cl-5.11(Injectors) |
- |
40000 |
|
- |
| Cl-5.12(Ignition Devices) |
- |
40000 |
|
- |
| Cl-5.13(Flame Supervision Devices) |
- |
40000 |
|
- |
| Cl-5.14(Burners and Radiant Elements) |
- |
40000 |
|
- |
| Cl-5.15(Grids) |
- |
40000 |
|
- |
| Cl-5.16(Turnspit) |
- |
40000 |
|
- |
| Cl-5.17(Fireguards for Heating Appliances) |
- |
40000 |
|
- |
| Cl-5.18(Locations and Compartments for Cartridge or Gas Cylinder) |
- |
40000 |
|
- |
| Cl-5.19(Verification of the Heat Inputs) |
- |
40000 |
|
- |
| Cl-5.20(Resistance to Overheating) |
- |
40000 |
|
- |
| Cl-5.21(Temperature of Various Parts of the Appliance) |
- |
40000 |
|
- |
| Cl-5.22(Temperature of Panels (Floors, Walls or Ceilings)) |
- |
40000 |
|
- |
| Cl-5.23(Ignition, Cross Lighting and Flame Stability) |
- |
40000 |
|
- |
| Cl-5.24(Resistance to Draught) |
- |
40000 |
|
- |
| Cl-5.25(Resistance to Liquid Spillage) |
- |
40000 |
|
- |
| Cl-5.26(Combustion) |
- |
40000 |
|
- |
| Cl-5.27(Accumulation of Un-Burnt Gas) |
- |
40000 |
|
- |
| Cl-5.28(Safety at High Temperature) |
- |
40000 |
|
- |
| Cl-5.29(Shooting – Condensation) |
- |
40000 |
|
- |
| Cl-5.30(Rational Use of Energy) |
- |
40000 |
|
- |
| Cl-5.30.1.2(Uncovered burners) |
- |
40000 |
|
- |
| Cl-5.30.1.3(Covered burners) |
- |
40000 |
|
- |
| Cl-5.31(Durability of Markings) |
- |
40000 |
|
- |
| Cl-5.32(Strength and Endurance Requirements) |
- |
40000 |
|
- |
|
13 May, 2028 |
- Included w.e.f.26.08.2025 |
| 1855 |
Sleen India Biz venture Private Limited, Agra
| 9139736
| IS 1254 (2025) |
Corrugated Aluminium Sheet (Fifth Revision) |
- |
14500 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl-4(FREEDOM FROM DEFECTS) |
- |
1000 |
|
- |
| Cl-5(SUPPLY OF MATERIALS) |
- |
3000 |
|
- |
| Cl-6(PROFILE) |
- |
500 |
|
- |
| Cl-7(MATERIAL) |
- |
6000 |
|
- |
| Cl-8.1(Tolerance on the thickness) |
- |
500 |
|
- |
| Cl-8.2(Width) |
- |
500 |
|
- |
| Cl-8.3(Length) |
- |
500 |
|
- |
| Cl-8.4(Squareness) |
- |
1000 |
|
- |
| Cl-8.5(Depth and Pitch of the Corrugation) |
- |
1000 |
|
- |
| Cl-10(Finish) |
- |
250 |
|
- |
| Cl-12(Marking) |
- |
250 |
|
- |
|
15 May, 2027 |
- Included w.e.f.26.08.2025 |
| 1856 |
Central Institute of Petrochemicals Engineering & Technology (CIPET), Chandrapur
| 7173804
| IS 17425 (2020) |
Irrigation Equipment - Quick Coupled Polyethylene Pipes and Fittings for Sprinkler Irrigation Systems - Specification |
Class-1 to 4/ Nominal Diameter 40mm to 200mm |
52900 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl.4.1.3(Den sity Test) |
- |
1125 |
|
Test Charges 500/- and Specimen preparation charges 625/- +GST Extra |
| Cl.4.1.3(MFR Test) |
- |
1100 |
|
+GST Extra |
| Cl.4.1.3(Thermal Stabi lity) |
- |
2200 |
|
+GST Extra |
| Cl.4.1.3, T-1(Volatile Matter) |
- |
700 |
|
+GST Extra |
| Cl.4.1.3, T-1(Water Content) |
- |
700 |
|
+GST Extra |
| 4.1.1 (Table-1)(Tensile strength at Yield & Elongation at break) |
- |
1350 |
|
Test Charges 1100/- and Specimen preparation charges 250/- +GST Extra |
| Cl.4.1.4(Carbon Black Content) |
- |
925 |
|
+GST Extra |
| Cl.4.1.4(Carbon Black Di spersion) |
- |
700 |
|
+GST Extra |
| Cl.5(Di men sion) |
- |
250 |
|
+GST Extra |
| Cl.5.1.l(Outside Diameter) |
- |
250 |
|
+GST Extra |
| Cl.6.2.L(Wall Thickness) |
- |
250 |
|
+GST Extra |
| 5.1.2(Squareness) |
- |
250 |
|
+GST Extra |
| 6(Visual Appearance) |
- |
300 |
|
+GST Extra |
| 4.1.1 (Table-1)(Density) |
- |
700 |
|
+GST Extra |
| 4.1.1 (Table-1)(Melt Flow Index) |
- |
1100 |
|
+GST Extra |
| 6.1(Thermal Stability (OIT)) |
- |
2200 |
|
+GST Extra |
| 6.1(Volatile Matter) |
- |
700 |
|
+GST Extra |
| 6.1(Water content) |
- |
700 |
|
+GST Extra |
| 6.1(Tensile strength at Yield & Elongation at break) |
- |
1350 |
|
Test Charges 1100/- and Specimen preparation charges 250/- +GST Extra |
| 6.2 b(Material Identification - Male & Female Coupler) |
- |
2100 |
|
+GST Extra |
| 6.2.1(Base Density x 2) |
- |
1400 |
|
+GST Extra |
| 6.2.1(Melt Flow Index x 2) |
- |
2200 |
|
+GST Extra |
| 6.2.1(Thermal Stability (OIT) x 2) |
- |
4400 |
|
+GST Extra |
| 6.2.1(Volatile Matter x 2) |
- |
1400 |
|
+GST Extra |
| 6.2.1(Water content x 2) |
- |
1400 |
|
+GST Extra |
| 6.2.1(Carbon Black Content x 2) |
- |
1850 |
|
+GST Extra |
| 6.2.1(Carbon Black Dispersion x 2) |
- |
1400 |
|
+GST Extra |
| 6.2.1(Wall thickness of male & female coupler) |
- |
500 |
|
+GST Extra |
| 6.2.4(Workmanship and appearance (Visual)) |
- |
300 |
|
+GST Extra |
| 6.2.5(Holding attachment for coupler parts) |
- |
1050 |
|
+GST Extra |
| 6.2.6(Material Identification (Chemical Analysis)) |
- |
1050 |
|
+GST Extra |
| 6.2.6(Color) |
- |
300 |
|
+GST Extra |
| 6.2.6(Rubber Ring Hardness Shore – A (Before Ageing)) |
- |
375 |
|
+GST Extra |
| 6.2.6(Ageing Charges for rubber ring) |
- |
4200 |
|
Conditioning Charges 4200/- +GST Extra |
| 6.3.3(Material Identification - Insert Valve Coupler) |
- |
1050 |
|
+GST Extra |
| 6.3.4() |
- |
300 |
|
+GST Extra |
| 6.3.5(Material Identification - Saddle) |
- |
1050 |
|
+GST Extra |
| 6.3.5(Material Identification - Pipe Ends) |
- |
1050 |
|
+GST Extra |
| 6.3.6(Quick Coupled Pump Connectors - Visual) |
- |
300 |
|
+GST Extra |
| 7.1.1(Visual appearance of pipes) |
- |
300 |
|
+GST Extra |
| 7.1.2((a) Acceptance Test (48 hrs) / 80˚ C) |
- |
1600 |
|
+GST Extra |
| 7.1.2((b) Type test ( 165 hrs) / 80˚ C) |
- |
4800 |
|
+GST Extra |
| 7.1.3(Reversion) |
- |
1000 |
|
Test charges 700/- Specimen preparation charges 300/- +GST Extra |
| 7.1.4(Tensile strength & elongation) |
- |
1350 |
|
Test charges 1100/- Specimen preparation charges 250/- +GST Extra |
| 7.1.5((a) Acceptance Test (48 hrs) / 80˚ C) |
- |
1600 |
|
+GST Extra |
| 7.1.5((b) Type test ( 165 hrs) / 80˚ C) |
- |
4800 |
|
+GST Extra |
| 7.1.6(Corrected Density) |
- |
700 |
|
+GST Extra |
| 7.1.7(Melt Flow Rate (MFR)) |
- |
1100 |
|
+GST Extra |
| 7.2.1(Leakage test 1hour / 27°C) |
- |
850 |
|
+GST Extra |
| 7.2.2(Hydraulic Proof test 1hour / 27°C) |
- |
850 |
|
+GST Extra |
| 7.2.3((a) Acceptance Test (48 hrs) / 80˚ C) |
- |
1600 |
|
+GST Extra |
| 7.2.3((b) Type test ( 165 hrs) / 80˚ C) |
- |
4800 |
|
+GST Extra |
| 7.3(Quick Couple Fitting) |
- |
0 |
|
- |
| 5(Dimensions of pipe - i) Outside diameter) |
- |
0 |
|
- |
| 5(Dimensions of pipe - ii) Wall thickness minimum) |
- |
0 |
|
- |
| 7.1(Hydraulic Characteristics - Quality test) |
- |
0 |
|
- |
| 7.1(Hydraulic Characteristics - Acceptance test) |
- |
0 |
|
- |
| 7.2(Reversion Test) |
- |
0 |
|
- |
| 7.3(Tensile Test- i) Tensile Strength) |
- |
0 |
|
- |
| 7.3(Tensile Test - ii)Elongation at Break) |
- |
0 |
|
- |
| 7.4(Fusion Compatibility Test- a) Quality test) |
- |
0 |
|
- |
| 7.4(Fusion Compatibility Test- b) Acceptance test) |
- |
0 |
|
- |
| 7.5(Density) |
- |
0 |
|
- |
| 7.6(Melt Flow Rate) |
- |
0 |
|
- |
| 7.6(Melt Flow Rate) |
- |
0 |
|
- |
| 4.2(Carbon black- a)carbon content) |
- |
0 |
|
- |
| 4.2(Carbon black- b) Dispersion of carbon black) |
- |
0 |
|
- |
| 7.6(Melt now Rate (MFR)) |
- |
0 |
|
- |
| 7.5(Density) |
- |
0 |
|
- |
| 7.4 Table-2(Fusion Compatibility Test) |
- |
0 |
|
- |
| 7.3(Tensile Test) |
- |
0 |
|
- |
| 7.2(Reversion Test) |
- |
0 |
|
- |
| 7.1 Table -2(Hydraulic Characteristics) |
- |
0 |
|
- |
| 6.1(VISUAL APPEARANCE) |
- |
0 |
|
- |
| 5.1.2(Ovality) |
- |
0 |
|
- |
| 5.1 table -1(DIMENSIONS OF PIPES) |
- |
0 |
|
- |
| Cl. 4.2 , IS 2530-1963, Cl. 10(Cabon Black Content) |
- |
0 |
|
- |
| 4.1.2(The MFR of the material shall be between 0.2 to 1.1 (both inclusive) when tested at 190 T at a nominal load of 50 N by the method prescribed in 7 of IS 2530. The MFR of the material shall also be within 20% of the value declared by the manufacturer.’) |
- |
0 |
|
- |
| 4.1.1(density shall be between 940.4 kg/m’ and 958.4 kg/m3 (both inclusive) when determined at 27°C according to procedure prescribed in Annex A of IS 7328. The value of the density shall also not differ from the nominal value by more than 3 kg/m2 as per 5.2.1.1 of IS 7328.) |
- |
0 |
|
- |
| 4.1(melt flow rating (MFR) shall not exceed 1.10 g/10 min.) |
- |
0 |
|
- |
| 3(CLASSIFICATION OF PIPES) |
- |
0 |
|
- |
| 4.1(Quick Coupled Male and Female Couplers) |
- |
0 |
|
- |
| 4.1(Quick Coupled Male and Female Couplers) |
- |
0 |
|
- |
| 4.1.3(Workmanship and appearance) |
- |
0 |
|
- |
| 4.1.4(Holding attachments for coupler parts) |
- |
0 |
|
- |
| 6.1.3(Weldability Test- a) Quality test) |
- |
0 |
|
- |
| 6.1.3(Weldability Test- b) Acceptance test) |
- |
0 |
|
- |
| 3(Quick Coupled pipes) |
- |
0 |
|
- |
| 3(QUICK COUPLED PIPES) |
- |
0 |
|
- |
| 4(QUICK COUPLED FITTINGS) |
- |
0 |
|
- |
| 4.1 (a)(Quick Coupled Male and Female Couplers) |
- |
0 |
|
- |
| 4.1 (b)(HDPE couplers —) |
- |
0 |
|
- |
| Cl. 4.1.1.2.1, IS 14151 (P-1)-1999, Cl. 4, IS 2530-1963, Cl. 10(Cabon Black Content) |
- |
0 |
|
- |
| Cl. 4.1.1.2.1, IS 14151 (P-1)-1999, Cl. 4, IS 2530-1963, Cl. 16(Carbon Black Dispersion) |
- |
0 |
|
- |
| 4.1 .1.2.1(HDPE couplers) |
- |
0 |
|
- |
| 4.1 .1.2.2(HDPE couplers) |
- |
0 |
|
- |
| 4.2.1(Quick Coupled ~pe HDPE Fittings) |
- |
0 |
|
- |
| 4.2.2(Quick Coupled ~pe HDPE Fittings) |
- |
0 |
|
- |
| 4.2.3(Quick Coupled ~pe HDPE Fittings) |
- |
0 |
|
- |
| 4.2.4(Quick Coupled ~pe HDPE Fittings) |
- |
0 |
|
- |
| 4.2.5(Quick Coupled ~pe HDPE Fittings) |
- |
0 |
|
- |
| 4.2.6(Quick Coupled ~pe HDPE Fittings) |
- |
0 |
|
- |
| 4.2.7(Quick Coupled ~pe HDPE Fittings) |
- |
0 |
|
- |
| 4.2.7(1 Dimensions of Quick Coupled Pipes and Fittings) |
- |
0 |
|
- |
| 4.2.7(Reducers Table 1 and 2 of IS 8008 (Part 4)) |
- |
0 |
|
- |
| 4.2.7(Ferrule reducers Table 1 of IS 8008 (Part 5)) |
- |
0 |
|
- |
| 4.2.7(Pipe ends Table 1 of IS 8008 (Part 6)) |
- |
0 |
|
- |
| 4.2.7(End caps Table 1 of IS 8008 (Part 9)) |
- |
0 |
|
- |
| 4.2.7(Insert vatve couplers Table 1 of IS 8008 (Part 3)) |
- |
0 |
|
- |
| 4.2.7(Valve openers Table 1 of IS 8008 (Part 2)) |
- |
0 |
|
- |
| 5.2(Dimensions of Quick Coupled Sprinkler Saddles Table 1.) |
- |
0 |
|
- |
| 6.1(Quick Coupled Pipes and Fittings) |
- |
0 |
|
- |
| 6.1.1, 6.1.1.1(Leakage Test) |
- |
0 |
|
- |
| 6.1.1, 6.1.1.1(Leakage Test) |
- |
0 |
|
- |
| 6.1.2, 6.1.2.1(Hydraulic Proof Test) |
- |
0 |
|
- |
| 6.1.2.2(Hydraulic Proof Test) |
- |
0 |
|
- |
| 6.1.2.2(Hydraulic Proof Test) |
- |
0 |
|
- |
| 6.1.3, 6.1.3.1(Weldability Test) |
- |
0 |
|
- |
| 6.1.3.1.1(Weldability Test) |
- |
0 |
|
- |
| 6.1.3.2(Quick coupled fittings) |
- |
0 |
|
- |
| 6.2, 6.2.1(Quick Coupled Fittings) |
- |
0 |
|
- |
| 7.2.1(Visual and Workmanship Requirement) |
- |
0 |
|
- |
| 6.3.3(Material Identification - Insert Valve Coupler) |
- |
0 |
|
- |
| 7.2.1(Leakage Test) |
- |
0 |
|
- |
| Cl.4.1.3(MFR Test) |
- |
0 |
|
- |
| Cl.4.1.3(MFR Test) |
- |
0 |
|
- |
| Cl.4.1.3(MFR Test) |
- |
0 |
|
- |
| Cl.4.1.3(Thermal Stabi lity) |
- |
0 |
|
- |
| Cl.4.1.3, T-1(Volatile Matter) |
- |
0 |
|
- |
| Cl.4.1.3, T-1(Volatile Matter) |
- |
0 |
|
- |
| Cl.4.1.3, T-1(Volatile Matter) |
- |
0 |
|
- |
| Cl.4.1.3, T-1(Volatile Matter) |
- |
0 |
|
- |
| Cl.4.1.3, T-1(Volatile Matter) |
- |
0 |
|
- |
| Cl.4.1.3, T-1(Volatile Matter) |
- |
0 |
|
- |
| Cl.4.1.3, T-1(Water Content) |
- |
0 |
|
- |
| Cl.4.1.3, T-1(Water Content) |
- |
0 |
|
- |
| Cl.4.1.3, T-1(Water Content) |
- |
0 |
|
- |
| Cl.4.1.3, T-1(Water Content) |
- |
0 |
|
- |
| Cl.4.1.3, T-1(Water Content) |
- |
0 |
|
- |
| Cl.4.1.3, T-1(Water Content) |
- |
0 |
|
- |
| Cl.4.1.3, T-1(Water Content) |
- |
0 |
|
- |
| Cl.4.1.3, T-1(Water Content) |
- |
0 |
|
- |
| Cl.4.1.3, T-1(Water Content) |
- |
0 |
|
- |
| Cl.4.1.3, T-1(Water Content) |
- |
0 |
|
- |
| Cl.4.1.3, T-1(Water Content) |
- |
0 |
|
- |
| Cl.4.1.3, T-1(Water Content) |
- |
0 |
|
- |
| Cl.4.1.3, T-1(Water Content) |
- |
0 |
|
- |
| Cl.4.1.3, T-1(Water Content) |
- |
0 |
|
- |
| Cl.4.1.3, T-1(Water Content) |
- |
0 |
|
- |
| Cl.4.1.3, T-1(Water Content) |
- |
0 |
|
- |
| Cl.4.1.3, T-1(Water Content) |
- |
0 |
|
- |
| Cl.4.1.3, T-1(Water Content) |
- |
0 |
|
- |
| Cl.4.1.4(Carbon Black Content) |
- |
0 |
|
- |
| Cl.4.1.4(Carbon Black Content) |
- |
0 |
|
- |
| Cl.4.1.4(Carbon Black Di spersion) |
- |
0 |
|
- |
| Cl.4.1.4(Carbon Black Di spersion) |
- |
0 |
|
- |
| Cl.5.1.l(Outside Diameter) |
- |
0 |
|
- |
| Cl.6.2.4(Workmanship and Appearance) |
- |
0 |
|
- |
| Cl.6.2.6(Rubber Ring Hardness) |
- |
0 |
|
- |
| Cl.6.2.6(Ageing Test) |
- |
0 |
|
- |
| Cl.7.1.l(Visual Anneara nce) |
- |
0 |
|
- |
| Cl.7.1.2(Hydraulic Characteristic) |
- |
0 |
|
- |
| Cl.7.1.2(Hydraulic Characteristic) |
- |
0 |
|
- |
| Cl.7.1.2(Hydraulic Characteristic) |
- |
0 |
|
- |
| Cl.7.1.2(Hydraulic Characteristic) |
- |
0 |
|
- |
| Cl.7.1.3(Reversion Test) |
- |
0 |
|
- |
| Cl.7.1.3(Reversion Test) |
- |
0 |
|
- |
| Cl.7.1.4(Tensile Test) |
- |
0 |
|
- |
| Cl.7.1.4(Tensile Test) |
- |
0 |
|
- |
| Cl.7.1.4(Tensile Test) |
- |
0 |
|
- |
| Cl.7.1.4(Elongation) |
- |
0 |
|
- |
| Cl.7.1.4(Elongation) |
- |
0 |
|
- |
| Cl.7.1.5(Fusion Compatibility) |
- |
0 |
|
- |
| Cl.7.1.5(Fusion Compatibility) |
- |
0 |
|
- |
| Cl.7.1.5(Fusion Compatibility) |
- |
0 |
|
- |
| Cl.7.1.5(Fusion Compatibility) |
- |
0 |
|
- |
| Cl.7.1.6(Corrected Density) |
- |
0 |
|
- |
| Cl.7.1.7(MFR Test) |
- |
0 |
|
- |
| Cl.7.1.7(MFR Test) |
- |
0 |
|
- |
| Cl.7.1.7(MFR Test) |
- |
0 |
|
- |
| Cl.7.1.7(MFR Test) |
- |
0 |
|
- |
| Cl.7.2.l(Leakage Test) |
- |
0 |
|
- |
| Cl.7.2.l(Leakage Test) |
- |
0 |
|
- |
| Cl.7.2.l(Leakage Test) |
- |
0 |
|
- |
| Cl.7.2.l(Leakage Test) |
- |
0 |
|
- |
| Cl.7.2.l(Leakage Test) |
- |
0 |
|
- |
| Cl.7.2.2(Cl.7.2.2) |
- |
0 |
|
- |
| Cl.7.2.3(Weld ability Test) |
- |
0 |
|
- |
| Cl.7.2.3(Weld ability Test) |
- |
0 |
|
- |
| 6.2 (iii) Rubber Rings (a) Shore hardness(Shore hardness) |
- |
0 |
|
- |
| 6.2 (iii) Rubber Rings (b) Accelerated Storage test(Accelerated Storage test) |
- |
0 |
|
- |
| 5(Dimensions of pipe (outside diameter, ovality, wall thickness)) |
- |
0 |
|
- |
| 6.1(Carbon Black Content) |
- |
0 |
|
- |
| 6.1(Carbon Black Dispersion) |
- |
0 |
|
- |
| 7.1.2(Hydraulic Characteristics) |
- |
0 |
|
- |
| 7.1.5(Fusion Compatibility test) |
- |
0 |
|
- |
| 7.1.6(Base Density) |
- |
0 |
|
- |
| 7.1.6(Carbon black Content) |
- |
0 |
|
- |
| 8(Supply of pipe (Visual)) |
- |
0 |
|
- |
| 4.1.1 (Table-1)(Oxidation Induction Time) |
- |
0 |
|
- |
| 4.1.1 (Table-1)(Volatile Matter) |
- |
0 |
|
- |
| 4.1.1 (Table-1)(Water content) |
- |
0 |
|
- |
| 4.1.4(Carbon Black Content) |
- |
0 |
|
- |
| 4.1.4(Carbon Black Dispersion) |
- |
0 |
|
- |
| 4.1.1(Polyethylene material) |
- |
0 |
|
- |
| 4.1.3, Table 1,(i)(Bass density) |
- |
0 |
|
- |
| 4.1.3, Table 1,(ii)(Melt flow rate) |
- |
0 |
|
- |
| 4.1.3, Table 1,(iii)(Thermal stability) |
- |
0 |
|
- |
| 4.1.3, Table 1,(iv)(Volatile matter) |
- |
0 |
|
- |
| 4.1.3, Table 1,(v)(Water content) |
- |
0 |
|
- |
| 4.1.3, Table 1,(vi)(Minimum tensile strength at yield) |
- |
0 |
|
- |
| 4.1.3, Table 1,(vii)(Minimum elongation at break) |
- |
0 |
|
- |
| 4.1.4(The Carbon Content and Dispersion) |
- |
0 |
|
- |
| 4.1.5(Carbon Black Specification) |
- |
0 |
|
- |
| 4.1.7(Rework Material) |
- |
0 |
|
- |
| 5.1, Table 1,(i)(Plain pipes) |
- |
0 |
|
- |
| 5.1, Table 1,(ii)(90° Bends and tee) |
- |
0 |
|
- |
| 5.1, Table 1,(iii)(Base pipe ) |
- |
0 |
|
- |
| 5.1, Table 1,(iv)(PCN) |
- |
0 |
|
- |
| 5.1, Table 1,(v)(Reducers, ferrule reducers) |
- |
0 |
|
- |
| 5.1, Table 1,(vi)(End caps, insert valve coupler, valve
openers) |
- |
0 |
|
- |
| 5.1, Table 1,(vii)(Riser pipe and socket) |
- |
0 |
|
- |
| 7.1.1(Visual Appearance and Workmanship) |
- |
0 |
|
- |
| 7.1.2(Hydraulic Performance Characteristic) |
- |
0 |
|
- |
| 7.1.3(Reversion Test) |
- |
0 |
|
- |
| 7.1.4(Tensile Test) |
- |
0 |
|
- |
| 7.1.5(Fusion Compatibility Test) |
- |
0 |
|
- |
| 7.1.6(Corrected Density) |
- |
0 |
|
- |
| 7.1.7(Melt flow rate) |
- |
0 |
|
- |
| 7.2.1(Leakage Test) |
- |
0 |
|
- |
| 7.2.2(Hydraulic Proof Test) |
- |
0 |
|
- |
| 7.2.3(Weldability Test) |
- |
0 |
|
- |
| 10(Marking) |
- |
0 |
|
- |
| Cl 6.3.5, Table 5 Dimension of Quick Coupled Sprinkler Saddles (Foot Batten)(Table 5 Dimension of Quick Coupled Sprinkler Saddles (Foot Batten)) |
- |
0 |
|
- |
| 4.1.4(a)(Holding Attachments for Coupler Parts) |
- |
0 |
|
- |
| 4.1.4(b)(Holding Attachments for Coupler Parts) |
- |
0 |
|
- |
| 4.2.2(Coating thickness (Hot dip Galvanized or Electroplated or Passivated or Powder Coated)) |
- |
0 |
|
- |
|
10 Sep, 2026 |
- Included w.e.f. 04.11.2025
Exclusion: "4.1.6 (Antioxidant) Antioxidant Raw Material TC is required by the
4.2 (Metallic Couplers) Compositional Analysis of Metallic Couplers
4.3 (Anti-oxidant) Antioxidant
6.2.5 (Material Composition (Chemical Analysis)) Compositional Analysis of Holding attachment for coupler parts" |
| 1857 |
Dashmesh Test Lab Private Limited
| 8186926
| IS 17681 (2022) |
Specification for Bottled water dispensers |
ALL TYPE |
205000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4(Construction) |
- |
5000 |
|
- |
| 4.1(General Design) |
- |
500 |
|
- |
| 4.2(Materials) |
- |
500 |
|
- |
| 4.3(Finish) |
- |
500 |
|
- |
| 4.4(Thermal Insulation) |
- |
500 |
|
- |
| 4.5(Hardware) |
- |
500 |
|
- |
| 4.6(Disposal of Waste Water) |
- |
500 |
|
- |
| 4.7(Hot Water Tank) |
- |
500 |
|
- |
| 4.8(Hermetically Sealed Compressor) |
- |
500 |
|
- |
| 4.9(Protective Guards) |
- |
5000 |
|
- |
| 5(Refrigeration System) |
- |
5000 |
|
- |
| 5.1(Pipes and Connections/Fitting) |
- |
500 |
|
- |
| 5.2(Control of Operation) |
- |
500 |
|
- |
| 6.1(General) |
- |
1500 |
|
- |
| 6.1(Protection against electric shock (Cl. 8 of IS 302-2-24)) |
- |
3500 |
|
- |
| 6.1(Power Input & Current (Cl. 10 of IS 302-2-24)) |
- |
5000 |
|
- |
| 6.1(Temperature Rise/ Heating (Cl. 11 of IS 302-2-24)) |
- |
5000 |
|
- |
| 6.1("Insulation Resistance and Electric Strength/ Leakage Current and Electric Strength
(Cl. 13 of IS 302-2-24)") |
- |
3500 |
|
- |
| 6.1("Moisture Resistance
(Cl. 15 of IS 302-2-24)") |
- |
4000 |
|
- |
| 6.1("Insulation resistance and electric strength
(After humidity treatment)
(Cl. 16 of IS 302-2-24)") |
- |
3500 |
|
- |
| 6.1("Provision For Earthing
(Cl. 27 of IS 302-2-24)") |
- |
4000 |
|
- |
| 6.1("Screws & Connections
(Cl. 28 of IS 302-2-24)") |
- |
3000 |
|
- |
| 6.2(Electrical Accessories) |
- |
1500 |
|
- |
| 6.3(Salt Mist Test) |
- |
25000 |
|
- |
| 7(Sound pressure level) |
- |
15000 |
|
- |
| 10.1(Cooling Capacity Test) |
- |
22000 |
|
- |
| 10.2(Maximum Operating Condition Test (Environmental)) |
- |
15000 |
|
- |
| 10.3(Maximum Operating Condition Test (Voltage)) |
- |
18000 |
|
- |
| 10.4(Heating Capacity Test) |
- |
18000 |
|
- |
| 10.5(Annual Energy Consumption Test) |
- |
35000 |
|
- |
| 10.6(Freeze-up Test) |
- |
20000 |
|
- |
| 10.7(Door Opening and Closing Test) |
- |
8000 |
|
- |
| 10.8(Door Seal Test) |
- |
2000 |
|
- |
| 10.9(Pull-down Test) |
- |
11000 |
|
- |
| 11(Marking and instruction) |
- |
1000 |
|
- |
|
22 Jul, 2028 |
- Included w.e.f. 14.10.2025 |
| 1858 |
Sleen India Biz venture Private Limited, Agra
| 9139736
| IS 15138 (2024) |
Textiles - Jute Bags For Packing 50 Kg Sugar - Specification (second revision) |
All Types |
6250 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| As per Clause 4.1(Febric) |
- |
250 |
|
- |
| As per Clause 4.1.1(Febric) |
- |
250 |
|
- |
| As per Clause 4.2(Seam) |
- |
250 |
|
- |
| As per Clause 4.3(Hemming at the mouth) |
- |
250 |
|
- |
| As per Clause 4.4(Freedom from defects) |
- |
500 |
|
- |
| As per Clause 5,5.1,5.2(Table 1)(i). Dimension,(a.-outside length) (b.-outside width)) |
- |
500 |
|
- |
| As per Clause 5,5.1,5.2(Table 1)(ii). Ends/dm) |
- |
500 |
|
- |
| As per Clause 5,5.1,5.2(Table 1)(iii). Picks/dm) |
- |
500 |
|
- |
| As per Clause 5,5.1,5.2(Table 1)(iv). Corrected mass per bags) |
- |
500 |
|
- |
| As per Clause 5,5.1,5.2(Table 1)(v). Average breaking load of sacking(a) warpway (b)weftway) |
- |
750 |
|
- |
| As per Clause 5,5.1,5.2(Table 1)(vi). Average breaking load of seam(a) warpway (b)weftway) |
- |
750 |
|
- |
| As per Clause 5,5.1,5.2(Table 1)(vii).Moisture regain) |
- |
500 |
|
- |
| As per Clause 5,5.1,5.2(Table 1)(viii).oil content) |
- |
750 |
|
- |
|
15 May, 2027 |
- Included w.e.f. 04.08.2025 |
| 1859 |
AA Electro Magnetic Laboratory Pvt Ltd, Gurugram
| 8165826
| IS 13450 : Part 2 : Sec 21 (2023) |
Medical Electrical Equipment Part 2 Particular Requirements for the Basic Safety and Essential Performance Section 21 Infant Radiant Warmer First Revision |
- |
1400000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 201.4(General requirements) |
- |
32000 |
|
- |
| 201.5(General requirements for testing ME EQUIPMENT) |
- |
40000 |
|
- |
| 201.6(Classification of ME EQUIPMENT and ME SYSTEMS) |
- |
33000 |
|
- |
| 201.7(ME EQUIPMENT identification, marking and documents) |
- |
15000 |
|
- |
| 201.8(Protection against electrical HAZARDS from ME EQUIPMENT) |
- |
100000 |
|
- |
| 201.9(Protection against MECHANICAL HAZARDS of ME EQUIPMENT and ME SYSTEMS) |
- |
45000 |
|
- |
| 201.10(Protection against unwanted and excessive radiation HAZARDS) |
- |
32000 |
|
- |
| 201.11(Protection against excessive temperatures and other HAZARDS) |
- |
45000 |
|
- |
| 201.12(Accuracy of controls and instruments and protection against hazardous outputs) |
- |
17000 |
|
- |
| 201.13(HAZARDOUS SITUATIONS and fault conditions for ME EQUIPMENT) |
- |
20000 |
|
- |
| 201.14(PROGRAMMABLE ELECTRICAL MEDICAL SYSTEMS (PEMS)) |
- |
22000 |
|
- |
| 201.15(Construction of ME EQUIPMENT) |
- |
24000 |
|
- |
| 201.16(ME SYSTEMS) |
- |
30000 |
|
- |
| 201.17(Electromagnetic compatibility of ME EQUIPMENT and ME SYSTEMS) |
- |
450000 |
|
- |
| 202(Electromagnetic disturbances – Requirements and tests) |
- |
495000 |
|
- |
| 201.4(General requirements) |
- |
0 |
|
- |
| 201.5(General requirements for testing ME EQUIPMENT) |
- |
0 |
|
- |
| 201.6(Classification of ME EQUIPMENT and ME SYSTEMS) |
- |
0 |
|
- |
| 201.7(ME EQUIPMENT identification, marking and documents) |
- |
0 |
|
- |
| 201.8(Protection against electrical HAZARDS from ME EQUIPMENT) |
- |
0 |
|
- |
| 201.9(Protection against MECHANICAL HAZARDS of ME EQUIPMENT and ME SYSTEMS) |
- |
0 |
|
- |
| 201.10(Protection against unwanted and excessive radiation HAZARDS) |
- |
0 |
|
- |
| 201.11(Protection against excessive temperatures and other HAZARDS) |
- |
0 |
|
- |
| 201.12(Accuracy of controls and instruments and protection against hazardous outputs) |
- |
0 |
|
- |
| 201.13(HAZARDOUS SITUATIONS and fault conditions for ME EQUIPMENT) |
- |
0 |
|
- |
| 201.14(PROGRAMMABLE ELECTRICAL MEDICAL SYSTEMS (PEMS)) |
- |
0 |
|
- |
| 201.15(Construction of ME EQUIPMENT) |
- |
0 |
|
- |
| 201.16(ME SYSTEMS) |
- |
0 |
|
- |
| 201.17(Electromagnetic compatibility of ME EQUIPMENT and ME SYSTEMS) |
- |
0 |
|
- |
| 202(Electromagnetic disturbances – Requirements and tests) |
- |
0 |
|
- |
|
24 Sep, 2026 |
- Included w.e.f.10.09.2025 |
| 1860 |
RAHUL ENGINEERS LABORATORY PRIVATE LIMITED
| 8189106
| IS 1489 (Part 1) (2015) |
Portland pozzolana cement - Specification: Part 1 fly Ash Based |
PORTLAND POZZOLANA CEMENT - FLY ASH BASED |
21100 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 7 -Table 2- vi(Drying Shrinkage- IS 4031 Part 10) |
- |
1000 |
|
- |
| 7 -Table 2- iv- c(Compressive Strength At 672 hrs ± 4 hr - IS 4031 Part 6) |
- |
1100 |
|
- |
| 7 -Table 2- iv- b(Compressive Strength At 168 hrs ± 2 hr - IS 4031 Part 6) |
- |
1100 |
|
- |
| 7 -Table 2- iv- a(Compressive Strength At 72 hrs ± 1 hr - IS 4031 Part 6) |
- |
1100 |
|
- |
| 7 -Table 2-iii- b(Setting Time Final- 4031 Part 5) |
- |
700 |
|
- |
| 7 -Table 2- iii- a(Setting Time Initial- 4031 Part 5) |
- |
700 |
|
- |
| 7 -Table 2- ii- b(Expansion after aeration- 4031 Part 3) |
- |
2400 |
|
- |
| 7 -Table 2- ii- b(Expansion by Autoclave- 4031 Part 3) |
- |
2400 |
|
- |
| 7 -Table 2- ii- a(Expansion after aeration - 4031 Part 3) |
- |
1500 |
|
- |
| 7 -Table 2- ii- a(Expansion by Le Chatelier- 4031 Part 3) |
- |
1500 |
|
- |
| 7 -Table 2- i(Fineness 4031 Part 2) |
- |
2400 |
|
- |
| 6 - Table - 1 vi( Alkali content as (Na2O + 0.658 K2O) - Cl 4.11 of IS 4032:1985) |
- |
600 |
|
- |
| 6 - Table - 1 v(Chloride content - Cl 4.13 of IS 4032:1985) |
- |
600 |
|
- |
| 6 - Table - 1 iv(Loss on ignition - Cl 7.1 of IS 4032:1985) |
- |
600 |
|
- |
| 6 - Table - 1 iii(Total Sulphur Content calculated as Sulphuric Anhydride (SO3) - Cl 7.3 of IS 4032:1985) |
- |
600 |
|
- |
| 6 - Table - 1 ii(Magnesia - Cl 7.2 of IS 4032:1985) |
- |
600 |
|
- |
| 6 - Table - 1 i(Insoluble residue - Cl 7.4 of IS 4032:1985) |
- |
600 |
|
- |
| 6 - Table - 1 vi( Alkali content as (Na2O + 0.658 K2O) - Cl 4.11 of IS 4032:1985) |
- |
600 |
|
- |
| 6 - Table - 1 v(Chloride content - Cl 4.13 of IS 4032:1985) |
- |
600 |
|
- |
| 6 - Table - 1 iv(Loss on ignition - Cl 7.1 of IS 4032:1985) |
- |
600 |
|
- |
| 6 - Table - 1 iii(Total Sulphur Content calculated as Sulphuric Anhydride (SO3) - Cl 7.3 of IS 4032:1985) |
- |
600 |
|
- |
| 6 - Table - 1 ii(Magnesia - Cl 7.2 of IS 4032:1985) |
- |
600 |
|
- |
| 6 - Table - 1 i(Insoluble residue - Cl 7.4 of IS 4032:1985) |
- |
600 |
|
- |
| 7 -Table 2- vi(Drying Shrinkage- IS 4031 Part 10) |
- |
1000 |
|
- |
| 7 -Table 2- iv- c(Compressive Strength At 672 hrs ± 4 hr - IS 4031 Part 6) |
- |
1100 |
|
- |
| 7 -Table 2- iv- b(Compressive Strength At 168 hrs ± 2 hr - IS 4031 Part 6) |
- |
1100 |
|
- |
| 7 -Table 2- iv- a(Compressive Strength At 72 hrs ± 1 hr - IS 4031 Part 6) |
- |
1100 |
|
- |
| 7 -Table 2-iii- b(Setting Time Final- 4031 Part 5) |
- |
700 |
|
- |
| 7 -Table 2- iii- a(Setting Time Initial- 4031 Part 5) |
- |
700 |
|
- |
| 7 -Table 2- ii- b(Expansion after aeration- 4031 Part 3) |
- |
2400 |
|
- |
| 7 -Table 2- ii- b(Expansion by Autoclave- 4031 Part 3) |
- |
2400 |
|
- |
| 7 -Table 2- ii- a(Expansion after aeration - 4031 Part 3) |
- |
1500 |
|
- |
| 7 -Table 2- ii- a(Expansion by Le Chatelier- 4031 Part 3) |
- |
1500 |
|
- |
| 7 -Table 2- i(Fineness 4031 Part 2) |
- |
2400 |
|
- |
| 6 - Table - 1 vi( Alkali content as (Na2O + 0.658 K2O) - Cl 4.11 of IS 4032:1985) |
- |
600 |
|
- |
| 6 - Table - 1 v(Chloride content - Cl 4.13 of IS 4032:1985) |
- |
600 |
|
- |
| 6 - Table - 1 iv(Loss on ignition - Cl 7.1 of IS 4032:1985) |
- |
600 |
|
- |
| 6 - Table - 1 iii(Total Sulphur Content calculated as Sulphuric Anhydride (SO3) - Cl 7.3 of IS 4032:1985) |
- |
600 |
|
- |
| 6 - Table - 1 ii(Magnesia - Cl 7.2 of IS 4032:1985) |
- |
600 |
|
- |
| 6 - Table - 1 i(Insoluble residue - Cl 7.4 of IS 4032:1985) |
- |
600 |
|
- |
| 6 - Table - 1 vi( Alkali content as (Na2O + 0.658 K2O) - Cl 4.11 of IS 4032:1985) |
- |
600 |
|
- |
| 6 - Table - 1 v(Chloride content - Cl 4.13 of IS 4032:1985) |
- |
600 |
|
- |
| 6 - Table - 1 iv(Loss on ignition - Cl 7.1 of IS 4032:1985) |
- |
600 |
|
- |
| 6 - Table - 1 iii(Total Sulphur Content calculated as Sulphuric Anhydride (SO3) - Cl 7.3 of IS 4032:1985) |
- |
600 |
|
- |
| 6 - Table - 1 i(Insoluble residue - Cl 7.4 of IS 4032:1985) |
- |
600 |
|
- |
| 6 - Table - 1 ii(Magnesia - Cl 7.2 of IS 4032:1985) |
- |
600 |
|
- |
| 7 -Table 2- v(Transverse Strength - IS 4031 Part 8 (Optional)) |
- |
4000 |
|
- |
|
27 Oct, 2028 |
- Clause 7 Table 2 SI No. (v) (Transverse Strength, 672 ± 4 h)
Clause 7Table 2 SI No. (v) (Transverse Strength, 168 ± 2 h)
Clause 7Table 2 SI No. (v) (Transverse Strength, 72 ± 1 h) |