121 |
IS 7092 : Part 2 (1987) |
Specification for aluminium alloy tube for irrigation purposes: Part 2 extruded tube (Second Revision) |
- |
-
|
Rs 11230/- View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
Cl.4 (Workmanship & Finish) |
- |
|
|
|
Cl.6.2 (Ultimate Tensile Strength- IS 2657) |
- |
|
|
|
Cl.6.2 (0.2 percent proof strength- IS 2657) |
- |
|
|
|
Cl.6.2 (Elongation on 50 mm gauge length- IS 2657) |
- |
|
|
|
Cl.7.1, Table 2 (Outside Diameter-) |
- |
|
|
|
Cl.7.1, Table 2 (Roundness or Ovality) |
- |
|
|
|
Cl.7.1, Table 2 (Wall Thickness) |
- |
|
|
|
Cl. 7.2 (Length) |
- |
|
|
|
|
Partial
|
|
- |
" 2 mt + 100g
Excluding Excl Hydrostatic Test, Chemical facility not available |
122 |
IS 7181 (1986) |
Specification for horizontally cast iron double flanged pipes for water, gas and sewage (First Revision) |
- |
-
|
Rs.6600/- View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
3.2 (Manufacture) |
- |
|
|
|
3.3 (Manufacture) |
- |
|
|
|
3.4 (Manufacture) |
- |
|
|
|
5.1 (Tensile Test) |
- |
|
|
|
7.1 (Sizes and Mass) |
- |
|
|
|
7.2 (Sizes and Mass) |
- |
|
|
|
7.3 (Sizes and Mass) |
- |
|
|
|
7.3 (Sizes and Mass) |
- |
|
|
|
7.4 (Sizes and Mass Dimensions of Flange) |
- |
|
|
|
8.5 (Permissible Deviation from a Straight Line) |
- |
|
|
|
|
Partial
|
|
- |
- |
123 |
IS 733 (1983) |
Specification for wrought aluminium and aluminium alloy bars, rods and sections (For General Engineering Purposes) (Third Revision) |
- |
-
|
- View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
Cl. 4 (Freedom from Defects) |
- |
|
|
|
Cl. 5.1, Table 2 (0.2 Percent proof stress- IS 1816) |
- |
|
|
|
Cl. 5.1, Table 2 (Tensile Strength- IS 1816) |
- |
|
|
|
Cl. 5.1, Table 2 (Elongation on 50 mm or 5.65√So Gauge Length) |
- |
|
|
|
|
Partial
|
|
- |
" 1 m
Excluding Facility for preparation of test specimen not available,Chemical facility not available |
124 |
IS 7452 (1990) |
Hot rolled steel sections for doors, windows and ventilators - Specification |
- |
-
|
Rs 1800/- View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
cl 6 (Dimensions) |
- |
|
|
|
cl 7 (MASS AND MASS TOLERANCE) |
- |
|
|
|
cl 8 (SURFACE FINISH) |
- |
|
|
|
|
Partial
|
|
- |
" 1.5 mt + 50g
Excluding Excl Bend Test, raw material |
125 |
IS 7142 (1995) |
Welded low carbon steel cylinders for low pressure liquifiable gases not exceeding 5 litre water capacity - Specification (First Revision) |
- |
-
|
Rs. 9552/- View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
6.2.2 (DESIGN) |
- |
|
|
|
10.1 (FITTINGS OTHER THAN VALVES) |
- |
|
|
|
10.2 i) (FITTINGS OTHER THAN VALVES) |
- |
|
|
|
10.3 (Bung) |
- |
|
|
|
13 (CHECKING OF WATER CAPACITY) |
- |
|
|
|
14.1.1 (PROOF TEST) |
- |
|
|
|
15.1 (PNEUMATIC LEAKAGE TEST) |
- |
|
|
|
16.2 ( Bursting Test) |
- |
|
|
|
17.1.1 & Cl.4.1 (ACCEPTANCE TESTS) |
- |
|
|
|
17.3 vii) (Acceptance test Weld joint test Specimen) |
- |
|
|
|
17.5 (Macro-examination) |
- |
|
|
|
17.6 (Minimum Thickness Test) |
- |
|
|
|
18.2 a) (MARKING) |
- |
|
|
|
18.2 b) (MARKING) |
- |
|
|
|
18.2 c) (MARKING) |
- |
|
|
|
18.2 d) (MARKING) |
- |
|
|
|
18.2 e) (MARKING) |
- |
|
|
|
18.2 f) (MARKING) |
- |
|
|
|
18.3 ( BIS Certification Marking) |
- |
|
|
|
19 (COLOUR IDENTIFICATION) |
- |
|
|
|
|
Complete
|
|
- |
" 2 cylinders
Excluding except raw material tests |
126 |
IS 778 (1984) |
Specification for 2010 copper alloy gate, globe and check valves for waterworks purposes (Fourth Revision) |
- |
-
|
Rs 4500/- View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
3 (Nominal Sizes ) |
- |
|
|
|
4 (Classification ) |
- |
|
|
|
5 (Types) |
- |
|
|
|
7.1.1 (Body End Ports -IS 778) |
- |
|
|
|
7.1.2 (Water-Way Area - IS 778) |
- |
|
|
|
7.1.3 (Screwed Body End -IS 778) |
- |
|
|
|
7.1.4 (Flanged Body End IS 778) |
- |
|
|
|
7.1.4.1- Table 3 (Thickness of flange - IS 778) |
- |
|
|
|
7.1.4.1- Table 3 (Diameter of Belt circle -IS 778) |
- |
|
|
|
7.1.4.1- Table 3 (No. of holes - IS 778) |
- |
|
|
|
7.1.4.1- Table 3 (Diameter of holes -IS 778) |
- |
|
|
|
7.1.4.1 (Holes in flange - IS 778) |
- |
|
|
|
7.1.5 (Wedge and Disc Guides in the Bodies of Gate Valves - IS 778) |
- |
|
|
|
7.2.1 (Bonnets - IS 778) |
- |
|
|
|
7.2.1.1 (Bonnets - IS 778) |
- |
|
|
|
7.2.1.2 (number of engaged threads - IS 778) |
- |
|
|
|
7.2.1.2 (pitch of threads - IS 778) |
- |
|
|
|
7.2.1.3 (Bonnets - IS 778) |
- |
|
|
|
7.2.2 (Bonnet Flanges - IS 778) |
- |
|
|
|
7.3 (Stuffing Box - IS 778) |
- |
|
|
|
7.4 (Gland - IS 778) |
- |
|
|
|
7.5 (Back Seat- IS 778) |
- |
|
|
|
7.6.1 (Stem - IS 778) |
- |
|
|
|
7.6.3 (actuating threads - IS 778) |
- |
|
|
|
7.6.4 (Length of Stem - IS 778) |
- |
|
|
|
7.6.5 (Upper end of Stem - IS 778) |
- |
|
|
|
7.6.6 (Rising Stem - IS 778) |
- |
|
|
|
7.6.6.1 (Rising Stem - IS 778) |
- |
|
|
|
7.6.7 (Non-rising Stem - IS 778) |
- |
|
|
|
7.7.1 (Wedge-IS 778) |
- |
|
|
|
7.7.2 (Wedge-IS 778) |
- |
|
|
|
7.7.3 (Double disc - IS 778) |
- |
|
|
|
7.7.3.1 (Spreading assembly - IS 778) |
- |
|
|
|
7.7.3.2 (Disc - IS 778) |
- |
|
|
|
7.8 (Disc Assembly for Globe Valves - IS 778) |
- |
|
|
|
7.8.1 (One-Piece Disc - IS 778) |
- |
|
|
|
7.8.2 (Renewable Disc Assembly - IS 778) |
- |
|
|
|
7.9 (Disc for Check Valves - IS 778) |
- |
|
|
|
7.9.1 (Disc of glove and Check Valves - IS 778) |
- |
|
|
|
7.10.1 (Body Seats - IS 778) |
- |
|
|
|
7.10.1 (Seat ring - IS 778) |
- |
|
|
|
7.11 (Handwheel - IS 778) |
- |
|
|
|
8.1- Table 4 (Thickness of Body and Bonnet- IS 778) |
- |
|
|
|
8.2 - Table 5 (Flat to Flat size -IS 778 ) |
- |
|
|
|
8.3 - Table 6 (Width of end - IS 778) |
- |
|
|
|
8.4 - Table 7 (Stem Diameters - IS 778) |
- |
|
|
|
8.5 - Table 8 (Size of packing space - IS 778) |
- |
|
|
|
8.5 - Table 8 (Dia of stuffing box - IS 778) |
- |
|
|
|
8.6- Table 9 to Table 12 (End to end/ centre to ends/ Face to face/Centre to face dimension ) |
- |
|
|
|
|
Partial
|
|
- |
" 1no+raw mat
Excluding except thread checking, raw material tests |
127 |
IS 9523 (2000) |
Ductile iron fittings for pressure pipes for water, gas and sewage - Specification (First Revision) |
- |
-
|
Rs.7245.00 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
Cl 5 (Thickness) |
- |
|
|
|
Cl 6 & Table 4,5,6&7 (Design & Tolerance) |
- |
|
|
|
Cl 9 (Tensile Test & Hardness Test) |
- |
|
|
|
Cl 11 (Nominal Diameter, Ovality, Dimensions, No. Of Holes & Bolt Sizes) |
- |
|
|
|
|
Partial
|
|
- |
- |
128 |
IS 1239 : Part 1 (2004) |
Steel tubes, tubulars and other wrought steel fittings - Specification: Part 1 steel tubes (Sixth Revision) |
- |
-
|
Rs. 9200/- Excluding test on joints View breakup
Rs. 9200/- Excluding test on joints
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
Cl 8 (Outer Diameter, Thickness & Mass) |
- |
|
|
|
Cl 15 (Workmanship) |
- |
|
|
|
Cl 14 (Tensile Test, Flattening Test & Bend Test) |
- |
|
|
|
Cl 14 (Tensile Test, Flattening Test & Bend Test) |
- |
|
|
|
|
Partial
|
|
- |
" 3m
Excluding excl bend test, joint (thread checking),hydrostatic test & Leak proof test (at manufacturer’s works), chemical tests. Facility for preparation of test specimen not available. |
129 |
IS 12592 (2002) |
Precast concrete manhole cover and frame - Specification (First Revision) |
- |
-
|
- View breakup
Rs 3000/- Excluding Load Test
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
3 (Grade) |
- |
|
|
|
3 (Type/Shape of Cover) |
- |
|
|
|
4.4 (Reinforcement) |
- |
|
|
|
4.5 (Steel Fibres - Diameter / equivalent diameterofsteel tibres) |
- |
|
|
|
5.2 and Table 1 (Dimensions of Frame - A) |
- |
|
|
|
5.2 and Table 1 (Dimensions of Frame - B) |
- |
|
|
|
5.2 and Table 1 (Dimensions of Frame - C) |
- |
|
|
|
5.2 and Table 1 (Dimensions of Frame - D) |
- |
|
|
|
5.2 and Table 1 (Dimensions of Frame - E) |
- |
|
|
|
5.2 and Table 1 (Dimensions of Frame - F) |
- |
|
|
|
5.2 (Dimensions of cover- Diameter) |
- |
|
|
|
5.2 (Clearance at top between the frame and the cover all round the periphery) |
- |
|
|
|
5.2 (Top surface ofthe frame and cover is in level) |
- |
|
|
|
5.2 (Suitable taper matching with taper given for the frame shall be provided to the periphery of the cover) |
- |
|
|
|
5.2 and Fig 1 (Clear cover to reinforcement) |
- |
|
|
|
5.2 and Fig 1 (Distance of housing from the edge) |
- |
|
|
|
7.4.1 (Edge Protection and Finishing - Frame) |
- |
|
|
|
7.4.1 (Edge Protection and Finishing - Frame) |
- |
|
|
|
7.4.2 (Edge Protection and Finishing - Cover) |
- |
|
|
|
7.4.2 (Edge Protection and Finishing - Cover) |
- |
|
|
|
8 (LIFTING HOOKS) |
- |
|
|
|
9.1 (General) |
- |
|
|
|
|
Partial
|
|
- |
" 1 no each
Excluding excl load test,raw material |
130 |
IS 10124 : Part 1 (2009) |
Fabricated PVC-U Fittings for Potable Water Supplies - Specification Part 1 General Requirements (Second Revision) |
- |
-
|
Rs 1500/- View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
4 (Size of fitting) |
- |
|
|
|
5.1 Table-1 Fig.1 (Dimension of Socket length) |
- |
|
|
|
5.1.3 (Out of Roundness Tolerance of Socket Inside Diameter) |
- |
|
|
|
5.2 Table-2 Fig.2 (Dimensions of socket for elastomeric sealing ring) |
- |
|
|
|
6.1 (Opacity test in accordance with IS 12235 (Part 3)) |
- |
|
|
|
6.2 (Short Term Hydraulic Test in accordance with Annex A) |
- |
|
|
|
8 (Marking) |
- |
|
|
|
|
Partial
|
|
- |
" 6 nos+1no.fitted with pipe
Excluding Except Short Term Hydrostatic Test,effect on water |
131 |
IS 4270 (2001) |
Steel tubes used for water wells specification (Third Revision) |
- |
-
|
Rs.7500/- View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
Cl 6 (Tensile Test & Flattening Test) |
- |
|
|
|
Cl 7 (Outer Diameter, Thickness, Mass & Straightness) |
- |
|
|
|
Cl 14 (Workmanship) |
- |
|
|
|
|
Partial
|
|
- |
" mech - 3 m
Excluding except Hydrostatic test, Pipe tube/ends, Sockets, Alignment test, Protective Coating, Protection of ends and Chemical tests |
132 |
IS 3748 (1990) |
Tool and die steels - Specification (Second Revision) |
- |
-
|
- View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
6 (Freedom from defects) |
- |
|
|
|
9.1 (Hardness , max-IS 1500 ) |
- |
|
|
|
10 (Dimensions and Tolerances, mm) |
- |
|
|
|
|
Partial
|
|
- |
" mech - 2 x 500 mm
Excluding except ultrasonic test and Chemical tests |
133 |
IS 8784 (1987) |
Specification for thermocouple compensating cables (Second Revision) |
- |
-
|
- View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
3.1 (Type of thermocouple) |
- |
|
|
|
4.1 (Conductor) |
- |
|
|
|
5 (INSULATION AND SHEATH) |
- |
|
|
|
6 (ARMOURING) |
- |
|
|
|
7 (SHIELDING) |
- |
|
|
|
8.1 (NOISE REDUCTION: Drain Wire) |
- |
|
|
|
8.2 (NOISE REDUCTION) |
- |
|
|
|
9.1 (DIMENSION : Single Wire) |
- |
|
|
|
9.1.1 (DIMENSION : Single Wire (Tolerances)) |
- |
|
|
|
9.1.2 (DIMENSION : Single Wire (Ovality)) |
- |
|
|
|
9.2.1 (Thickness of Insulation ) |
- |
|
|
|
9.2.2 (Thickness of Sheath ) |
- |
|
|
|
9.3 (Dimension of cable ) |
- |
|
|
|
10.1 (Colour Code ) |
- |
|
|
|
11.1 (ENVIRONMENTS FOR USE OF DIFFERENT THERMOCOUPLE
COMPENSATING CABLES) |
- |
|
|
|
12.1 (INFORMATION TO BE SUPPLIED BY THE MANUFACTURER) |
- |
|
|
|
13.1 (PACKING AND MARKING) |
- |
|
|
|
13.2 (PACKING AND MARKING) |
- |
|
|
|
13.2.1 (Standard Mark) |
- |
|
|
|
14.3 (Resistance Test) |
- |
|
|
|
14.4.1 ( Thickness of Insulation) |
- |
|
|
|
14.4.2.1 ( Thickness of Sheath : Round ) |
- |
|
|
|
14.4.2.2 ( Thickness of Sheath : Oval ) |
- |
|
|
|
14.5 (Insulation Resistance Test :Volume resistivity ( Before High Voltage test )) |
- |
|
|
|
15.5 (Insulation Resistance Test :Insulation resistance constant ( Before High Voltage test )) |
- |
|
|
|
14.5 (Insulation Resistance Test: Volume resistivity ( After High Voltage test )) |
- |
|
|
|
15.5 (Insulation Resistance Test: Insulation Resisatnce constant ( After High Voltage test )) |
- |
|
|
|
14.7 (H.V. Test ) |
- |
|
|
|
14.8 (Heat Shock Test) |
- |
|
|
|
|
Partial
|
|
- |
Excluding Except Thermal EMF Test (14.2), Rubber (5.1) and Asbestos (5.3) |
134 |
IS 3589 (2001) |
Steel pipes for water and sewage (168.3 To 2540 Mm Outside Diameter) - Specification (Third Revision) |
- |
-
|
- View breakup
Rs. 11800/- (for SAW Pipe ) Rs. 10380/- for (ERW Fe410 , Fe450 &Fe330)
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
11.1, Table 5. (Outside Diameter (OD)) |
- |
|
|
|
11.1, Table 5. (Thickness) |
- |
|
|
|
11.1, Table 5. (Mass) |
- |
|
|
|
14.1 (Visual inspection, Appearance and Workmanship) |
- |
|
|
|
14.4 (Visual inspection, Appearance and Workmanship-Dent Length) |
- |
|
|
|
12.3.3 (Ovality) |
- |
|
|
|
12.5 (Strightness) |
- |
|
|
|
|
Partial
|
|
- |
" 2 mt
excluding chem test,Hydraulic Pressure Test, Guided Bend Test. Prepared test piece needed for Tensile test Facility |
135 |
IS 3575 (1993) |
Bitumen drums - Specification (Third Revision) |
- |
-
|
- View breakup
Rs. 1800/- and Material testing charges as per relevant referred Iss
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
4.1 (Dimensions Drums (Figure 1)) |
- |
|
|
|
4.1 (Dimensions Closure (Figure 2)) |
- |
|
|
|
5.1 (Body and ends) |
- |
|
|
|
5.2 (Closures) |
- |
|
|
|
6.1 (Construction) |
- |
|
|
|
7.1 (Finish) |
- |
|
|
|
7.2 (Finish) |
- |
|
|
|
6.2 (Construction) |
- |
|
|
|
6.3 (Construction) |
- |
|
|
|
6.4 (Construction) |
- |
|
|
|
8 (Air Pressure Test) |
- |
|
|
|
4.1 (Dimensions Drums (Figure 1)) |
- |
|
|
|
|
Partial
|
|
- |
- |
136 |
IS 3502 (2009) |
Steel chequered plates (Third Revision) |
- |
-
|
- View breakup
Rs. 2985/- and material testing charges as per relevant referred Iss
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
Cl 5 (Workmanship) |
- |
|
|
|
Cl 8 (UTM) |
- |
|
|
|
Cl 9 (Press) |
- |
|
|
|
Cl 10 (Length, Width, Thickness & Chequered Height) |
- |
|
|
|
Cl 10 (Length, Width, Thickness & Chequered Height) |
- |
|
|
|
Cl 9 (Press) |
- |
|
|
|
|
Partial
|
|
- |
" 1.5 sq m
Excluding except Chemical tests |
137 |
IS 1783 : Part 2 (2014) |
Drums large, fixed ends - Specification: Part 2 grade B drums (Fourth Revision) |
- |
-
|
- View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
4 (Capacity) |
- |
|
|
|
5 (Dimensions (Type 1 C Drums Figure 1)) |
- |
|
|
|
5 (Dimensions (Type 1 D Drums Figure 1)) |
- |
|
|
|
5 (Dimensions (Type 1 D Drums Figure 1)) |
- |
|
|
|
5 (Dimensions (Type 1 D Drums Figure 1)) |
- |
|
|
|
5 (Dimensions (Type 1 D Drums Figure 1)) |
- |
|
|
|
5 (Dimensions (Type 1 D Drums Figure 1)) |
- |
|
|
|
5 (Dimensions (Type 1 C Drums Figure 2)) |
- |
|
|
|
5 (Dimensions (Type 1 C Drums Figure 2)) |
- |
|
|
|
5 (Dimensions (Type 1 C Drums Figure 2)) |
- |
|
|
|
5 (Dimensions (Type 1 C Drums Figure 2)) |
- |
|
|
|
5 (Dimensions (Type 1 C Drums Figure 2)) |
- |
|
|
|
5 (Dimensions (Type 1 C Drums Figure 2)) |
- |
|
|
|
5 (Dimensions (Type 1 D Drums Figure 2)) |
- |
|
|
|
6 (Material) |
- |
|
|
|
7 (Construction) |
- |
|
|
|
7.1 (Construction) |
- |
|
|
|
7.2 (Construction) |
- |
|
|
|
7.3 (Construction) |
- |
|
|
|
7.4 (Construction) |
- |
|
|
|
7.5 (Construction) |
- |
|
|
|
7.7 (Construction) |
- |
|
|
|
8 (Finish ) |
- |
|
|
|
9.1 (Leakage at air pressure ) |
- |
|
|
|
9.2 (Drop Test) |
- |
|
|
|
9.3 (Hydraulic Pressure Test) |
- |
|
|
|
|
Partial
|
|
- |
- |
138 |
IS 3319 (1995) |
Blades, surgical, detachable (Bard Parker Type) and handles - Specification (Fourth Revision) |
- |
-
|
Rs.1650/- View breakup
For physical tests(Excluding Sterility Test) Rs 2860/- for chemical tests Carbon Steel Blade Rs. 3360/- for chemical tests Stainless steel blade & Rs. 3360/- for chemical tests for Handle
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
8,8.1 (Sterilization) |
- |
|
|
|
8.2 (Sterilization) |
- |
|
|
|
5,5.1 & 5.2; Table 1 (Shape and dimensions) |
- |
|
|
|
6,6.1 (Workmanship and Finish) |
- |
|
|
|
6,6.2 (Workmanship and Finish) |
- |
|
|
|
6,6.3 (Workmanship and Finish) |
- |
|
|
|
6,6.4 (Workmanship and Finish) |
- |
|
|
|
7.1 (Hardness test) |
- |
|
|
|
9.1 ( Visual Examination) |
- |
|
|
|
9.2 ( Performance Test) |
- |
|
|
|
10.1.1 ( Marking on Blade) |
- |
|
|
|
10.1.2 (Packages of Non-sterile Blades) |
- |
|
|
|
10.1.3,10.1.3.1 (Packages of sterile Blades,Unit containers for sterile Blades) |
- |
|
|
|
10.1.3,10.1.3.2 (Packages of sterile Blades , Outer containers for sterile blade) |
- |
|
|
|
10.2 ( Handles) |
- |
|
|
|
10.2.2 ( Packages of Handles) |
- |
|
|
|
|
Partial
|
|
- |
" Mech - 50 nos./ Micro - 30nos.
except Chemical tests and Hardness |
139 |
IS 432 : Part 2 (1982) |
Mild Steel and Medium Tensile Steel Bars and Hard-Drawn Steel Wire for Concrete Reinforcement: Part 2 Hard-Drawn Steel Wire |
- |
-
|
Rs 3900/- View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
Cl 4.1 (Workmanship) |
- |
|
|
|
Cl 5 & 6 (Diameter) |
- |
|
|
|
Cl 7 (UTM) |
- |
|
|
|
Cl 4.1 (Workmanship) |
- |
|
|
|
Cl 5 & 6 (Diameter) |
- |
|
|
|
Cl 7 (UTM) |
- |
|
|
|
|
Partial
|
|
- |
1m
Excluding TF for chemical tests not available.Tensile test Facility available till 20mm only |
140 |
IS 3312 (1984) |
steel shelving cabinets (adjustable type) -Specification |
- |
-
|
Rs.2325.00 (excluding material testing charges) View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
3.1-Table 1 (DIMENSIONs-Size) |
- |
|
|
|
3.1-Table 1 (DIMENSIONs-Height) |
- |
|
|
|
3.1-Table 1 (DIMENSIONs-Width) |
- |
|
|
|
3.1-Table 1 (DIMENSIONs-Dept) |
- |
|
|
|
4.2 (Fabrication-Slides-Thickness) |
- |
|
|
|
4.2 (Fabrication-Slides) |
- |
|
|
|
4.3 (Fabrication-Back) |
- |
|
|
|
4.3 (Fabrication-Back) |
- |
|
|
|
4.4 (Fabrication-Top and Bottom) |
- |
|
|
|
4.4 (Fabrication-Top and Bottom) |
- |
|
|
|
4.10.2 (Fabrication-Lockers-Doors) |
- |
|
|
|
4.5 (Fabrication-Shelves) |
- |
|
|
|
4.4 (Fabrication-Top and Bottom-Thickness) |
- |
|
|
|
4.5 (Fabrication-Shelves -Thickness) |
- |
|
|
|
4.5 (Fabrication-Shelves -width) |
- |
|
|
|
4.5 (Fabrication-Shelves -Depth) |
- |
|
|
|
4.5 (Fabrication-Shelves) |
- |
|
|
|
4.5 (Fabrication-Shelves-bracket) |
- |
|
|
|
4.5 (Fabrication-Shelves) |
- |
|
|
|
4.5 (Fabrication-Shelves) |
- |
|
|
|
4.5 (Fabrication-Shelves-Rack strips) |
- |
|
|
|
4.5.1 (Fabrication-Shelves-Self supporting Arrangements) |
- |
|
|
|
4.6.1 (Fabrication-Doors-Right Door-Thickness) |
- |
|
|
|
4.6.1 (Fabrication-Doors-Right Door-The centre-tocentre distance between two adjacent welding spots or rivets) |
- |
|
|
|
4.6.1 (Fabrication-Doors-Right Door) |
- |
|
|
|
4.6.1 (Fabrication-Doors-Right Door-The clearance around the door between the door flanges and side, top and bottom flanges) |
- |
|
|
|
4.6.2 (Fabrication-Doors-Left Door) |
- |
|
|
|
4.6.2 (Fabrication-Doors-Left Door) |
- |
|
|
|
4.6.2 (Fabrication-Doors-Left Door-The clearance around the door between the door flanges and side, top and bottom flanges) |
- |
|
|
|
4.7 (Fabrication-Pedestal -Thickness) |
- |
|
|
|
4.7 (Fabrication-Pedestal -Height) |
- |
|
|
|
4.8 (Fabrication-Hinges-Type) |
- |
|
|
|
4.8 (Fabrication-Hinges-Thickness) |
- |
|
|
|
4.9 (Fabrication-Locks) |
- |
|
|
|
4.10-Table 2 (Fabrication-Lockers-INSIDE DIMENSIONS OF LOCKERS-Size) |
- |
|
|
|
4.10-Table 2 (Fabrication-Lockers-INSIDE DIMENSIONS OF LOCKERS-height) |
- |
|
|
|
4.10-Table 2 (Fabrication-Lockers-INSIDE DIMENSIONS OF LOCKERS-Width) |
- |
|
|
|
4.10-Table 2 (Fabrication-Lockers-INSIDE DIMENSIONS OF LOCKERS-Depth) |
- |
|
|
|
4.10.2 (Fabrication-Lockers-Doors) |
- |
|
|
|
4.10.2 (Fabrication-Lockers-Doors) |
- |
|
|
|
4.10.2 (Fabrication-Lockers-Doors-thickness) |
- |
|
|
|
4.10.2 (Fabrication-Lockers-Doors-) |
- |
|
|
|
4.10.2 (Fabrication-Lockers-Doors-Thickness) |
- |
|
|
|
4.10.4 (Fabrication-Drawer -Thickness) |
- |
|
|
|
|
Partial
|
|
- |
" 1 No.
Excluding except performance requirements of finish, Load Test & Material test |
141 |
IS 432 : Part 1 (1982) |
Mild Steel and Medium Tensile Steel Bars and Hard-Drawn Steel Wire for Concrete Reinforcement: Part 1 Mild Steel and Medium Tensile Steel Bars |
- |
-
|
Rs 2100/- View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
Cl 5.1 (Workmanship) |
- |
|
|
|
Cl 6.2 (Diameter & Ovality) |
- |
|
|
|
Cl 6.2 (Weight) |
- |
|
|
|
Cl 8.2 (Bend test) |
- |
|
|
|
Cl 6.1 (Diameter) |
- |
|
|
|
|
Partial
|
|
- |
" 1m + 25g
Excluding except chemical tests up to 20mm |
142 |
IS 4947 (2006) |
Foam concentrate for producing mechanical foam for fire fighting - Specification (Fourth Revision) |
- |
-
|
- View breakup
Rs. 10200/- and testing charges as per relevant referred ISs.
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
Cl 3 (General Requirements) |
- |
|
|
|
Cl 8 (Finish) |
- |
|
|
|
|
Partial
|
|
- |
" 2 no. "
Excluding hydraulic & burst pressure tests and chem tests |
143 |
IS 3039 (1988) |
Specification for structural steel for construction of hulls of ships (Second Revision) |
- |
-
|
- View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
5 (Freedom from defects) |
- |
|
|
|
10.2 (Tensile Test-1608:Part 1) |
- |
|
|
|
10.2 (Yield Stress, Mpa) |
- |
|
|
|
10.2 (Elongation, %) |
- |
|
|
|
12 and 13 (Dimensions and Tolerances) |
- |
|
|
|
|
Partial
|
|
- |
" mech - 1 m
Excluding except impact test and Chemical tests |
144 |
IS 4948 (2020.0) |
Welded steel wire fabric for general use - Specification (Second Revision) |
- |
-
|
- View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
Cl. 5.1 (MANUFACTURE OF MESH (Assembling of Wires)) |
- |
|
|
|
Cl. 5.2 (MANUFACTURE OF MESH) |
- |
|
|
|
Cl. 5.3 (MANUFACTURE OF MESH) |
- |
|
|
|
Cl. 5.4 (Spacing of Longitudinal and Transverse Wires) |
- |
|
|
|
Cl. 5.5 (Tolerance of Size of Mesh) |
- |
|
|
|
Cl. 5.6 (Tolerance of Size of Sheet or Roll) |
- |
|
|
|
Cl. 9.1 (Marking) |
- |
|
|
|
Cl. 9.3 (BIS Certification Marking) |
- |
|
|
|
Cl. 10.1 (Finish) |
- |
|
|
|
|
Partial
|
|
- |
1mt
Excluding excl shear strength test & chemical tests |
145 |
IS 2879 (1998) |
Mild steel for metal arc welding electrodes - Specification (Third Revision) |
- |
-
|
Testing charges are Rs.9050/- View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
Cl 7 (Workmanship) |
- |
|
|
|
Cl 8 & 9 (Diameter) |
- |
|
|
|
|
Partial
|
|
- |
" 1 mt + 50 gm
Excluding excluding chemical tests |
146 |
IS 280 (2006) |
Mild steel wire for general engineering purposes (Fourth Revision) |
- |
-
|
Rs.3750.00 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
Cl 9 (Tensile Test On UTM) |
- |
|
|
|
Cl 13 (Workmanship) |
- |
|
|
|
Cl 7 & Table 1 (Diameter & Difference Between Two Reading On Any Two Diameters) |
- |
|
|
|
|
Partial
|
|
- |
" 3 m+ 50gm "
Excluding Mech-C / Chem - except Aluminium and Copper |
147 |
IS 5484 (1997) |
Ec grade aluminium rod produced by continuous casting and rolling - Specification (Second Revision) |
- |
-
|
- View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
10.1 (Diameter - IS:5484) |
- |
|
|
|
8-Table-1 (Tensile Strength - IS:1608) |
- |
|
|
|
9 (Resistyvity at 20 degree C -IS:398(P-2)) |
- |
|
|
|
11.1 (Joint- IS:5484) |
- |
|
|
|
12.2 (Finish - IS:5484) |
- |
|
|
|
|
Partial
|
|
- |
" 3 m
Excluding chem facility not available. |
148 |
IS 5489 (1975) |
Specification for carburizing steels for use in bearing industry (First Revision) |
- |
-
|
- View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
7 ( HARDNESS) |
- |
|
|
|
11.3 (i) Tolerance on Length -IS : 3739-1972) |
- |
|
|
|
11.4 (ii)Tolerance on Straightness) |
- |
|
|
|
12 ( SIZE AND WEIGHT OF WIRE AND WIRE ROD) |
- |
|
|
|
|
Partial
|
|
- |
" 2 x 1 m "
Excluding except inclusion content, Grain size and Chemical tests |
149 |
IS 2681 (1993) |
Non - Ferrous metal sliding door bolts (Aldrops) for use with padlocks - Specification (Third Revision) |
- |
-
|
- View breakup
Rs.1500/- and Material testing charges as per relevant referred Iss
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
Cl. 8.1 (Brass sliding door bolts shall have satin
finish or shall be polished or plated as specified by the purchaser) |
- |
|
|
|
Cl. 8.2 (Ref. Cl.9 of IS 1868:1996) (Anodinc casting thickness (Cl. 9.2 of IS 1868:1996)) |
- |
|
|
|
4 (SIZES) |
- |
|
|
|
6.1-Total 2 (DIMENSIONS AND TOLERANCES-A) |
- |
|
|
|
6.1-Total 2 (DIMENSIONS AND TOLERANCES-B) |
- |
|
|
|
6.1-Total 2 (DIMENSIONS AND TOLERANCES-C) |
- |
|
|
|
6.1-Total 2 (DIMENSIONS AND TOLERANCES-D) |
- |
|
|
|
6.1-Total 2 (DIMENSIONS AND TOLERANCES-E) |
- |
|
|
|
6.1-Total 2 (DIMENSIONS AND TOLERANCES-F) |
- |
|
|
|
6.1-Total 2 (DIMENSIONS AND TOLERANCES-G) |
- |
|
|
|
6.1-Total 2 (DIMENSIONS AND TOLERANCES-H) |
- |
|
|
|
6.1-Total 2 (DIMENSIONS AND TOLERANCES-L) |
- |
|
|
|
6.1-Total 2 (DIMENSIONS AND TOLERANCES-M) |
- |
|
|
|
6.1-Table 3 (DIMENSIONS AND TOLERANCES-R) |
- |
|
|
|
6.1-Table 3 (DIMENSIONS AND TOLERANCES-T) |
- |
|
|
|
6.1-Table 3 (DIMENSIONS AND TOLERANCES-U) |
- |
|
|
|
7.1 (MANUFACTURE-General) |
- |
|
|
|
7.1 (MANUFACTURE-General) |
- |
|
|
|
8.1 (FINISH) |
- |
|
|
|
3 (TYPES) |
- |
|
|
|
6.1-Total 2 (DIMENSIONS AND TOLERANCES-J) |
- |
|
|
|
6.1-Total 2 (DIMENSIONS AND TOLERANCES-K) |
- |
|
|
|
6.1-Total 2 (DIMENSIONS AND TOLERANCES-N) |
- |
|
|
|
6.1-Total 2 (DIMENSIONS AND TOLERANCES-Q) |
- |
|
|
|
6.1-Total 2 (DIMENSIONS AND TOLERANCES-S) |
- |
|
|
|
6.1-Total 2 (DIMENSIONS AND TOLERANCES-W) |
- |
|
|
|
6.1-Total 2 (DIMENSIONS AND TOLERANCES-No. of Screw on Staple or Clip to accommodate Wood Screw N0 8) |
- |
|
|
|
6.1-Table 3 (DIMENSIONS AND TOLERANCES-A) |
- |
|
|
|
6.1-Table 3 (DIMENSIONS AND TOLERANCES-B) |
- |
|
|
|
6.1-Table 3 (DIMENSIONS AND TOLERANCES-C) |
- |
|
|
|
6.1-Table 3 (DIMENSIONS AND TOLERANCES-D) |
- |
|
|
|
6.1-Table 3 (DIMENSIONS AND TOLERANCES-E) |
- |
|
|
|
6.1-Table 3 (DIMENSIONS AND TOLERANCES-F) |
- |
|
|
|
6.1-Table 3 (DIMENSIONS AND TOLERANCES-H) |
- |
|
|
|
6.1-Table 3 (DIMENSIONS AND TOLERANCES-J) |
- |
|
|
|
6.1-Table 3 (DIMENSIONS AND TOLERANCES-K) |
- |
|
|
|
6.1-Table 3 (DIMENSIONS AND TOLERANCES-L) |
- |
|
|
|
6.1-Table 3 (DIMENSIONS AND TOLERANCES-M) |
- |
|
|
|
6.1-Table 3 (DIMENSIONS AND TOLERANCES-Pin dia) |
- |
|
|
|
6.1-Table 3 (DIMENSIONS AND TOLERANCES-R) |
- |
|
|
|
6.1-Table 3 (DIMENSIONS AND TOLERANCES-T) |
- |
|
|
|
6.1-Table 3 (DIMENSIONS AND TOLERANCES-U) |
- |
|
|
|
6.1-Table 3 (DIMENSIONS AND TOLERANCES-No. of Screw on Staple or Clip to accommodate Wood Screw N0 8) |
- |
|
|
|
7.1 (MANUFACTURE-General) |
- |
|
|
|
7.2 (MANUFACTURE-Brass Sliding Door Bolts or Aluminium Alloy
Sliding Door Bolts) |
- |
|
|
|
7.2 (MANUFACTURE-Brass Sliding Door Bolts or Aluminium Alloy
Sliding Door Bolts) |
- |
|
|
|
8.2 (FINISH) |
- |
|
|
|
8.2 (FINISH-anodic casting -Min Avg thickness) |
- |
|
|
|
8.2 (FINISH-anodic casting -Min Local thickness) |
- |
|
|
|
|
Partial
|
|
- |
" 3+2 Nos.
Excluding except chemical tests and anodic coating |
150 |
IS 2385 (1977) |
Specification for hot - Rolled mild steel sheet and strip in coil form for cold - Reduced tinplate and cold - Reduced blackplate (First Revision) |
- |
-
|
- View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
6 (Freedom from defects) |
- |
|
|
|
8 (Dimensions and Tolerances) |
- |
|
|
|
|
Partial
|
|
- |
" Mech- 2 x 500 mm
Excluding except Chemical tests |