S.No. Indian Standard No. Product Grade / Type / Size / Designation etc. Testing Charges (Excl. Of Taxes) Validity Date Remark
121 IS 903 (1993) Specification for Fire Hose Delivery Couplings, Branch Pipe, Nozzles And Nozzle Spanner - Specificaion - Rs 3600/ View breakup
-
- -
" 1 pcs Excluding Except Hydraulic Test Requirement, Deflection Test Requirement,chemical tests
122 IS 13997 (2014) Drums, large open top - Specification (First Revision) - - View breakup
-
- -
-
123 IS 2653 (2004) Safety matches in boxes - Specification (Third Revision) - Rs 2570.00 View breakup
-
- -
" 2 dozen
124 IS 3196 : Part 2 (2006) Welded low carbon steel cylinders exceeding 5 litre water capacity for low pressure liquefiable gases: Part 2 cylinders for liquefiable non - Toxic gases other than lpg - Specification (First Revision) - Please see remarks. View breakup
-
- -
2nos Excluding except material test, Hydrostatic stretch test,RADIOGRAPHIC EXAMINATION (Prepared Test piece needed for Acceptance Test). Test facility for hydrostatic test is limited to 360Kg/cm2 pressure.
125 IS 6006 (2014) Uncoated stress relieved strand for prestressed concrete - Specification (Second Revision) - Rs 4035/- Excluding Proof Stress and Relaxation Test View breakup
-
- -
" 3 mts + 50g Excluding Strands upto 9.5 mm 7-Ply only,chemical tests and Excl Breaking strength, proof stress, Elongation and stress relaxation tests.
126 IS 2556 : Part 6 (1995) Vitreous sanitary appliances (Vitreous China): Part 6 specific requirements of urinals and partition plates - - View breakup
-
- -
2nos
127 IS 2556 : Part 7 (1995) Vitreous sanitary appliances (Vitreous China) - specification: Part 7 specific requirements of accessories for sanitary appliances - - View breakup
-
- -
2nos
128 IS 2098 (1997) Asbestos cement building boards - Specification (First Revision) - 3300 View breakup
Complete testing charges
- -
" 2 nos. Excl load bearing capacity test
129 IS 3196 : Part 4 (2001) Welded low carbon steel cylinders exceeding 5 litre water capacity for low pressure liquefiable gases - Specification: Part 4 cylinders for toxic and corrosive gases - Please see remarks. View breakup
-
- -
5 Excluding Excl 1.Hydrostatic stretch test 2.Nicked bend test 3.Radiographic examination Facility for preparation of test specimen not available,Chemical facility not available
130 IS 1812 (1982) Specification for carbon steel wire for the manufacture of wood screws (Second Revision) - 825 View breakup
-
- -
" 3m + 100g drill. Excluding chemical facility not available.
131 IS 5517 (1993) Steels for hardening and tempering - Speicification (Second Revision) - Rs 13670/- excluding Grain size, Cleanliness of steel, View breakup
-
- -
25g Excluding TF for only tensile strength and elongation is available,
132 IS 204 : Part 2 (1992) Tower bolts - Specification: Part 2 non - Ferrous metals (Fifth Revision) - Rs.2100.00. View breakup
-
- -
" 3x2 pcs+ 50 g Excluding Excl material test
133 IS 1726 (1991) Cast iron manhole covers and frames - Specification (Third Revision) - Rs 3225.00 View breakup
-
- -
" 5 Nos.+1 piece for coating excl load test, raw material tests
134 IS 1341 (2018) Steel Butt Hinges - Specification (Sixth Revision) - - View breakup
-
- -
" 6 pcs + raw matl Excluding Exc Chem analysis
135 IS 704 (1984) Specification for crow - Bars and claw - Bars (Second Revision) - Total Rs.11x 300 = Rs.3300.00 View breakup
-
- -
1 Excluding Static load test,raw material tests
136 IS 7092 : Part 2 (1987) Specification for aluminium alloy tube for irrigation purposes: Part 2 extruded tube (Second Revision) - Rs 11230/- View breakup
-
- -
" 2 mt + 100g Excluding Excl Hydrostatic Test, Chemical facility not available
137 IS 7181 (1986) Specification for horizontally cast iron double flanged pipes for water, gas and sewage (First Revision) - Rs.6600/- View breakup
-
- -
-
138 IS 733 (1983) Specification for wrought aluminium and aluminium alloy bars, rods and sections (For General Engineering Purposes) (Third Revision) - Please see remarks View breakup
-
- -
" 1 m 5 pieces for chemical testing Excluding Facility for preparation of test specimen not available
139 IS 7452 (1990) Hot rolled steel sections for doors, windows and ventilators - Specification - Rs 1800/- View breakup
-
- -
" 1.5 mt + 50g Excluding Excl Bend Test, raw material
140 IS 7142 (1995) Welded low carbon steel cylinders for low pressure liquifiable gases not exceeding 5 litre water capacity - Specification (First Revision) - Rs. 9552/- View breakup
-
- -
" 2 cylinders Excluding except raw material tests
141 IS 778 (1984) Specification for 2010 copper alloy gate, globe and check valves for waterworks purposes (Fourth Revision) - Rs 4500/- View breakup
-
- -
" 1no+raw mat Excluding except thread checking, raw material tests
142 IS 9523 (2000) Ductile iron fittings for pressure pipes for water, gas and sewage - Specification (First Revision) - Rs.7245.00 View breakup
-
- -
-
143 IS 1239 : Part 1 (2004) Steel tubes, tubulars and other wrought steel fittings - Specification: Part 1 steel tubes (Sixth Revision) - Rs. 9200/- Excluding test on joints View breakup
-
- -
" 3m Chemical Facility is available Quantity: 5 Pieces of 5cm X 5cm Excluding excl bend test, joint (thread checking),hydrostatic test & Leak proof test (at manufacturer’s works). Facility for preparation of test specimen not available.
144 IS 12592 (2002) Precast concrete manhole cover and frame - Specification (First Revision) - 1809 View breakup
-
- -
1 no each COMPLETE TEST FACILITY AVAILABLE
145 IS 10124 : Part 1 (2009) Fabricated PVC-U Fittings for Potable Water Supplies - Specification Part 1 General Requirements (Second Revision) - Rs 1500/- View breakup
-
- -
" 6 nos+1no.fitted with pipe Excluding Except Short Term Hydrostatic Test,effect on water
146 IS 4270 (2001) Steel tubes used for water wells specification (Third Revision) - Rs.7500/- View breakup
-
- -
" mech - 3 m Chemical Facility is available Quantity: 5 Pieces of 5cm X 5cm Excluding except Hydrostatic test, Pipe tube/ends, Sockets, Alignment test, Protective Coating, Protection of ends
147 IS 3748 (1990) Tool and die steels - Specification (Second Revision) - - View breakup
-
- -
" mech - 2 x 500 mm Excluding except ultrasonic test and Chemical tests
148 IS 8784 (1987) Specification for thermocouple compensating cables (Second Revision) - - View breakup
-
- -
Excluding Except Thermal EMF Test (14.2), Rubber (5.1) and Asbestos (5.3)
149 IS 3589 (2001) Steel pipes for water and sewage (168.3 To 2540 Mm Outside Diameter) - Specification (Third Revision) - Please see remarks. View breakup
-
- -
" 2 mt Chemical Facility is available Quantity: 5 Pieces of 5cm X 5cm excluding Hydraulic Pressure Test, Guided Bend Test. Prepared test piece needed for Tensile test Facility
150 IS 3575 (1993) Bitumen drums - Specification (Third Revision) - 1800.00 View breakup
-
- -
-