BIS, Southern Regional Laboratory (SRL)

IV CROSS ROAD, CIT CAMPUS, TARAMANI, CHENNAI-600113, TAMILNADU, CHENNAI, Chennai, Tamil Nadu, 600113
- srol@bis.gov.in
Scope List
Reset
266 Results
S.No. Indian Standard No. Product Grade / Type / Size / Designation etc. Exclusion Testing Charges (Excl. Of Taxes) Facility Type Effective Date Validity Date Remark
211 IS 14255 (1995) Aertal bunched cables - For working voltages up to and including 1100 Volts - Specification - - - View breakup
Rs.16650.00 for XLPE insulated single core cable Rs.15150.00 for PE insulated single core cable
Partial - " 15m Excluding 1.)Complete for XLPE Insulation ; 2.)Except Carbon black test , Melt flow index , Vicat softening point , Environmental stress cracking test for PE insulation, Except C1 & C2 Category
212 IS 9537 : Part 3 (1983) Specification for conduits for electrical installations: Part 3 rigid plain conduits of insulating meterials - - Rs. 3300.00/, Rs. 2850.00/ View breakup
-
Complete - 6x3m
213 IS 12045 (1987) Specification for alloys used in electrical resistance metallic heating elements - - - View breakup
-
Partial - " mech - 2 x 500 mm Excluding except Chemical tests
214 IS 1165 (2002) Milk powder - Specification (First Revision) - - - View breakup
-
Partial - " 2 x 500 g Excluding Microbiology Complete
215 IS 398 : Part 5 (1992) Aluminium conductor for overhead transmission purposes - Specification: Part 5 aluminium conductors - Galvanized steel - Reinforced for extra high voltage (400 KV And Above) (First Revision) - - 11400 View breakup
Excluding Breaking load on complete conductor, Surface condition test, Corona test and Radio interference test
Partial - " 5 m Excluding Except surface, carona & Radio Interference Test
216 IS 11952 (1986) Specification for steels for piston pins (Gudgeon Pins) - - - View breakup
-
Partial - " mech - 2 x 500 mm Excluding except inclusions test, magnetic particle test, Grain size, hardenability, surface defects and Chemical tests
217 IS 1785 : Part 2 (1983) Specification for plain hard drawn steel wire for prestressed concrete: Part 2 as - Drawn wire (First Revision) - - Rs 3000/- View breakup
-
Partial - " 2mtl. Excluding Except proof load, ductility, stress relaxation & reverse bend test
218 IS 1159 (1981) Specification for baking powder (First Revision) - - Rs.2100/- View breakup
-
Complete - " 500 g
219 IS 1785 : Part 1 (1983) Specification for plain hard - Drawn steel wire for prestressed concrete: Part 1 cold drawn stress - Relieved wire (Second Revision) - - Rs. 27300.00 (Complete testing charges) Rs. 9300.00 (F View breakup
-
Partial - " 2mt.+2m " Excluding Except proof load, ductility, stress relaxation & reverse bend test
220 IS 398 : Part 2 (1996) Aluminium conductors for overhead transmission purposes - Specification: Part 2 aluminium conuuctors, galvanized steel - Reinforced (Third Revision) - - - View breakup
(I) For galvanized steel core only (consisting of 7 steel strands)- Rs.2850.00, (II) For galvanized steel reinforced stranded conductors with nominal aluminium area upto and including 100mm2-(a) For single steel wire core (1 steel + 6 Aluminium)- Rs. 1950.00 (b) For 7 wire core (7 steel + 6 Aluminium) - Rs. 4000.00, (III) For galvanized steel reinforced stranded conductors with nominal aluminium area more than 100mm2 (excluding special tests as per Cl. 13.9, 13.10 & 13.11)-(a) For stranded conductors with 37 strands-Rs.7900/-, (b) For stranded conductors with 49 strands-Rs.10000/-, (c) For stranded conductors with 61 strands-Rs.11100/-,
Partial - " 5 m Excluding 1.)Complete upto 100 sq mm 2.)Except surface condition test, ultimate breaking load test on stranded conductor above 100 sqmm & stress strain test on conductor
221 IS 11947 (1987) Specification for soft magnetic iron rods, bars, flats and sections - - - View breakup
-
Partial - " mech - 2 x 500 mm Excluding except bend test and chemical tests
222 IS 12146 (1987) Specification for carbon manganese steel forgings for pressure vessels - - - View breakup
-
Partial - " mech - 100 gm drillings " Excluding except ultrasonic test and Chemical tests
223 IS 14542 (1998) Partly skimmed milk powder specification - - - View breakup
-
Complete - " 2 x 500 g "
224 IS 4505 (2015) Sodium formaldehyde sulphoxylate - Specification (First Revision) - - - View breakup
Testing charges for the product are Rs. 4480/-. Testing Charges for keeping quality: Rs. 4330/-.
Complete - " 500 g x 2 1 pack for keeping quality test as per clause 5 "
225 IS 336 (1973) Specification for ether - - - View breakup
-
Partial - " 500 ml x 2 Excluding except distillation range, relative density
226 IS 1161 (2014) Steel tubes for structural purposes - Specification (Fifth Revision) - - - View breakup
Rs. 5725/- and material testing charges as per relevant referred Iss
Partial - " mech - 1.5 m Excluding except cold bend test and chemical tests
227 IS 10109 (2018) Oil pressure stoves - Offset burner type - Specification (Second Revision) - - - View breakup
-
Partial - " 1 set " Excluding Except Burner assembly, Washer, Workmanship, Fuel Consumption & Thermal efficiency ,
228 IS 3205 (1984) Specification for precipitated barium carbonate, technical (First Revision) - - Rs 1575/- Grade 1; Rs 1125/- for Gr 2 View breakup
-
Partial - " 500 g " Excluding except carbonates for all grades, residue retained on 63 microns IS sieve for grade 1
229 IS 11587 (1986) Specification for structural weather resistant steels - - - View breakup
Rs 5600/- (rounded off to nearest Rs 50/-) Chemical parameters in Table 1 is Rs. 8600/- (rounded off to nearest 50/-).
Partial - " 1 m Excluding except chemical tests (Prepared test pieces are required for Impact test)
230 IS 398 : Part 1 (1996) Aluminium conductors for overhead transmission purposes - Specification: Part 1 aluminium stranded conductors (Third Revision) AAAC - Rs.1600/- for 7 strands, Rs.3750/- for 19 strands View breakup
-
Complete - " 5 m "
231 IS 398 : Part 4 (1994) Aluminium conductors for overhead transmission purposes: Part 4 aluminium alloy stranded conductors (Aluminium - Magnesium - Silicon Type) - Specification (Third Revision) AAAC - Rs 825/- upto 7 wires, Rs 1425/- upto 19 wires View breakup
-
Complete - 5 m
232 IS 11169 : Part 2 (1989) Steels for cold heading/cold extrusion applicationsspecification: Part 2 stainless steels - - - View breakup
-
Partial - " mech - 2 x 1 m Excluding except chemical tests
233 IS 261 (1982) Specification for copper sulphate (Second Revision) - - - View breakup
Rs 2400/- for Tech., Rs 3900/- for Pure
Complete - " 500 g
234 IS 1660 (2009) Wrought aluminium utensils - Specification (First Revision) - - Rs 6760/- View breakup
-
Partial - " 2 nos Excluding Excl. Tests for Non-stick Coating and tests for lunch boxes cl. 8.6.,no chemical tests
235 IS 6452 (1989) High alumina cement for structural use - specification (First Revision) - - Testing charges for the product are: 3,700.00 Testing View breakup
-
Partial - " 8 kg + 500 g " Excluding chem facility not available.
236 IS 1554 : Part 1 (1988) Specification for pvc insulated (Heavy Duty) electric cables: Part 1 for working voltages up to and including 1100 v (Third Revision) - - - View breakup
Rs.16650/- for single core unarmoured cable, Rs.22500/- for two core, unarmoured cable, Rs.26700/- for two core armoured cable (Excluding addl. Type test for cables with improved fire performance.) For multi core cables, extra charges @ 35 % for each additional core shall be levied. Material testing charges as per relevant referred ISs Testing charges for Additional Type Tests for Improved Fire Performance Tests: Rs. 7100/- for category C1 Rs. 11700/- for category C2
Partial - " 15m Excluding Except improved fire performance test for C1,C2 category(Optional tests)
237 IS 11536 (2007) Processed - Cereal based complementary foods - Specification (Second Revision) - - Rs.29460.00 View breakup
-
Partial - 2X250g Excluding facility available for only microbiology tests, No chemical tests facility
238 IS 10325 (2000) Square tins - 15 kg/litre for ghee, vanaspati, edible oils and bakery shortenings - Specification (Second Revision) - - - View breakup
Rs.3700/- (excluding Solder testing) and Rs.1500/- for solder testing.
Partial - " 3 Nos. " Excluding Chemical facility(tin Coating test) not available.
239 IS 15962 (2012) Structural steels for buildings and structures with improved seismic resistance - - - View breakup
-
Partial - " 1.5 m " Excluding except tensile test for the samples of diameter above 20 mm and chemical tests; (Prepared test pieces are required for Impact test)
240 IS 1029 (1970) Specification for hot-rolled steel strip (Baling) (First Revision) - - Rs.750/- View breakup
-
Partial - " 0.5 sq.m Excluding except tensile, bend test and chemical tests

Designed, Developed and Maintained by: